Beilke, Michael C; Beres, Martin J; Olesik, Susan V
2016-03-04
A "green" hydrophilic interaction liquid chromatography (HILIC) technique for separating the components of mixtures with a broad range of polarities is illustrated using enhanced-fluidity liquid mobile phases. Enhanced-fluidity liquid chromatography (EFLC) involves the addition of liquid CO2 to conventional liquid mobile phases. Decreased mobile phase viscosity and increased analyte diffusivity results when a liquefied gas is dissolved in common liquid mobile phases. The impact of CO2 addition to a methanol:water (MeOH:H2O) mobile phase was studied to optimize HILIC gradient conditions. For the first time a fast separation of 16 ribonucleic acid (RNA) nucleosides/nucleotides was achieved (16min) with greater than 1.3 resolution for all analyte pairs. By using a gradient, the analysis time was reduced by over 100% compared to similar separations conducted under isocratic conditions. The optimal separation using MeOH:H2O:CO2 mobile phases was compared to MeOH:H2O and acetonitrile:water (ACN:H2O) mobile phases. Based on chromatographic performance parameters (efficiency, resolution and speed of analysis) and an assessment of the environmental impact of the mobile phase mixtures, MeOH:H2O:CO2 mixtures are preferred over ACN:H2O or MeOH:H2O mobile phases for the separation of mixtures of RNA nucleosides and nucleotides. Copyright © 2016 Elsevier B.V. All rights reserved.
Shan, Yi-chu; Zhang, Yu-kui; Zhao, Rui-huan
2002-07-01
In high performance liquid chromatography, it is necessary to apply multi-composition gradient elution for the separation of complex samples such as environmental and biological samples. Multivariate stepwise gradient elution is one of the most efficient elution modes, because it combines the high selectivity of multi-composition mobile phase and shorter analysis time of gradient elution. In practical separations, the separation selectivity of samples can be effectively adjusted by using ternary mobile phase. For the optimization of these parameters, the retention equation of samples must be obtained at first. Traditionally, several isocratic experiments are used to get the retention equation of solute. However, it is time consuming especially for the separation of complex samples with a wide range of polarity. A new method for the fast optimization of ternary stepwise gradient elution was proposed based on the migration rule of solute in column. First, the coefficients of retention equation of solute are obtained by running several linear gradient experiments, then the optimal separation conditions are searched according to the hierarchical chromatography response function which acts as the optimization criterion. For each kind of organic modifier, two initial linear gradient experiments are used to obtain the primary coefficients of retention equation of each solute. For ternary mobile phase, only four linear gradient runs are needed to get the coefficients of retention equation. Then the retention times of solutes under arbitrary mobile phase composition can be predicted. The initial optimal mobile phase composition is obtained by resolution mapping for all of the solutes. A hierarchical chromatography response function is used to evaluate the separation efficiencies and search the optimal elution conditions. In subsequent optimization, the migrating distance of solute in the column is considered to decide the mobile phase composition and sustaining time of the latter steps until all the solutes are eluted out. Thus the first stepwise gradient elution conditions are predicted. If the resolution of samples under the predicted optimal separation conditions is satisfactory, the optimization procedure is stopped; otherwise, the coefficients of retention equation are adjusted according to the experimental results under the previously predicted elution conditions. Then the new stepwise gradient elution conditions are predicted repeatedly until satisfactory resolution is obtained. Normally, the satisfactory separation conditions can be found only after six experiments by using the proposed method. In comparison with the traditional optimization method, the time needed to finish the optimization procedure can be greatly reduced. The method has been validated by its application to the separation of several samples such as amino acid derivatives, aromatic amines, in which satisfactory separations were obtained with predicted resolution.
De Pauw, Ruben; Swier, Tim; Degreef, Bart; Desmet, Gert; Broeckhoven, Ken
2016-11-18
The limits in operating pressures are extended for narrow-bore columns in gradient elution up to 2000bar. As the required pumps for these pressures are incompatible with common chromatographic solvents and are not suitable to apply a mobile phase composition gradient, a mobile phase delivery and injection system is described and experimentally validated which allows to use any possible chromatographic solvent in isocratic and gradient elution. The mobile phase delivery and injection system also allows to perform multiple separations without the need to depressurize the column. This system consists out of 5 dual on/off valves and two large volume loops in which the gradient and equilibration volume of initial mobile phase are loaded by a commercial liquid chromatography pump. The loops are then flushed toward the column at extreme pressures. The mobile phase delivery and injection system is first evaluated in isocratic elution and shows a comparable performance to a state-of-the-art commercial flow-through-needle injector but with twice the pressure rating. Distortion of the loaded gradient by dispersion in the gradient storage loop is studied. The effect of the most important parameters (such as flow rate, pressure and gradient steepness) is experimentally investigated. Different gradient steepnesses and volumes can be applied at different flow rates and operating pressures with a good repeatability. Due to the isobaric operation of the pumps, the gradient is monitored in real-time by a mass flow meter installed at the detector outlet. The chromatograms are then converted from time to volume-base. A separation of a 19-compound sample is performed on a 300×2.1mm column at 1000bar and on a 600×2.1mm column at 2000bar. The peak capacity was found to increase from 141 to 199 and thus scales with L as is predicted by theory. This allows to conclude that the inlet pressure for narrow-bore columns in gradient elution can be increased up to 2000bar without fundamental pressure-induced limitations. Copyright © 2016 Elsevier B.V. All rights reserved.
Sun, Xiaoli; Hao, Weiqiang; Wang, Junde; Di, Bin; Chen, Qiang; Zhuang, Wei; Yu, Qiang; Zhang, Peipei
2013-08-01
By not explicitly specifying the type of solvent strength model, the features of ladder-like gradient elution were studied based on the general retention time formula that was derived in our previous work. For the case where the solute is eluted at like gradient, we derived the expression that connects the mobile phase composition (phiR), at which the solute is eluted from the column, with the gradient slope (B). It was shown that phiR will increase with the increase of B in this case. For the case where the solute is eluted at the last isocratic segment of the ladder-like gradient, it was proven that the retention time (tR) will correlate linearly with the reciprocal of the gradient slope (1/B) when the initial and final mobile phase compositions are set to be constant. In experiments, by taking biphenyl as the sample, the values of retention time in isocratic and gradient elution were measured on a C18 column by using a mixture of methanol and water as the mobile phase. The experimental values were found to be well consistent with the theoretical values that were calculated from the expressions. These expressions will be helpful to understand the features of the ladder-like gradient in practice.
Vaňková, Nikola; Česla, Petr
2017-02-17
In this work, we have investigated the predictive properties of mixed-mode retention model and oligomeric mixed-mode model, taking into account the contribution of monomeric units to the retention, in hydrophilic interaction liquid chromatography. The gradient retention times of native maltooligosaccharides and their fluorescent derivatives were predicted in the oligomeric series with number of monomeric glucose units in the range from two to seven. The maltooligosaccharides were separated on a packed column with carbamoyl-bonded silica stationary phase and 15 gradient profiles with different initial and final mobile phase composition were used with the gradient times 5; 7.5 and 10min. The predicted gradient retention times were compared for calculations based on isocratic retention data and gradient retention data, which provided better accuracy of the results. By comparing two different mobile phase additives, the more accurate retention times were predicted in mobile phases containing ammonium acetate. The acidic derivatives, prepared by reaction of an oligosaccharide with 2-aminobenzoic acid or 8-aminonaphthalene-1,3,6-trisulfonic acid, provided more accurate predictions of the retention data in comparison to native oligosaccharides or their neutral derivatives. The oligomeric mixed-mode model allowed prediction of gradient retention times using only one gradient profile, which significantly speeded-up the method development. Copyright © 2017 Elsevier B.V. All rights reserved.
Andrés, Axel; Rosés, Martí; Bosch, Elisabeth
2015-03-13
Retention of ionizable analytes under gradient elution depends on the pH of the mobile phase, the pKa of the analyte and their evolution along the programmed gradient. In previous work, a model depending on two fitting parameters was recommended because of its very favorable relationship between accuracy and required experimental work. It was developed using acetonitrile as the organic modifier and involves pKa modeling by means of equations that take into account the acidic functional group of the compound (carboxylic acid, protonated amine, etc.). In this work, the two-parameter predicting model is tested and validated using methanol as the organic modifier of the mobile phase and several compounds of higher pharmaceutical relevance and structural complexity as testing analytes. The results have been quite good overall, showing that the predicting model is applicable to a wide variety of acid-base compounds using mobile phases prepared with acetonitrile or methanol. Copyright © 2015 Elsevier B.V. All rights reserved.
Linear solvation energy relationships in normal phase chromatography based on gradient separations.
Wu, Di; Lucy, Charles A
2017-09-22
Coupling the modified Soczewiñski model and one gradient run, a gradient method was developed to build a linear solvation energy relationship (LSER) for normal phase chromatography. The gradient method was tested on dinitroanilinopropyl (DNAP) and silica columns with hexane/dichloromethane (DCM) mobile phases. LSER models built based on the gradient separation agree with those derived from a series of isocratic separations. Both models have similar LSER coefficients and comparable goodness of fit, but the LSER model based on gradient separation required fewer trial and error experiments. Copyright © 2017 Elsevier B.V. All rights reserved.
Hutta, Milan; Ráczová, Janka; Góra, Róbert; Pessl, Juraj
2015-08-21
Novel anion-exchange liquid chromatographic method with step gradient of aqueous EDTA(4-) based mobile phase elution has been developed to profile available Slovak soil humic substances and alkaline extracts of various soils. The method utilize short glass column (30mm×3mm) filled in with hydrolytically stable particles (60μm diameter) Separon HEMA-BIO 1000 having (diethylamino)ethyl functional groups. Step gradient was programmed by mixing mobile phase composed of aqueous solution of sodium EDTA (pH 12.0; 5mmolL(-1)) and mobile phase constituted of aqueous solution of sodium EDTA (pH 12.0, 500mmolL(-1)). The FLD of HSs was set to excitation wavelength 480nm and emission wavelength 530nm (λem). Separation mechanism was studied by use of selected aromatic acids related to humic acids with the aid of UV spectrophotometric detection at 280nm. The proposed method benefits from high ionic strength (I=5molL(-1)) of the end mobile phase buffer and provides high recovery of humic acids (98%). Accurate and reproducible profiling of studied humic substances, alkaline extracts of various types of soils enables straightforward characterization and differentiation of HSs in arable and forest soils. Selected model aromatic acids were used for separation mechanism elucidation. Copyright © 2015 Elsevier B.V. All rights reserved.
Kaczmarski, Krzysztof; Poe, Donald P; Guiochon, Georges
2010-10-15
When chromatography is carried out with high-density carbon dioxide as the main component of the mobile phase (a method generally known as "supercritical fluid chromatography" or SFC), the required pressure gradient along the column is moderate. However, this mobile phase is highly compressible and, under certain experimental conditions, its density may decrease significantly along the column. Such an expansion absorbs heat, cooling the column, which absorbs heat from the outside. The resulting heat transfer causes the formation of axial and radial gradients of temperature that may become large under certain conditions. Due to these gradients, the mobile phase velocity and most physico-chemical parameters of the system (viscosity, diffusion coefficients, etc.) are no longer constant throughout the column, resulting in a loss of column efficiency, even at low flow rates. At high flow rates and in serious cases, systematic variations of the retention factors and the separation factors with increasing flow rates and important deformations of the elution profiles of all sample components may occur. The model previously used to account satisfactorily for the effects of the viscous friction heating of the mobile phase in HPLC is adapted here to account for the expansion cooling of the mobile phase in SFC and is applied to the modeling of the elution peak profiles of an unretained compound in SFC. The numerical solution of the combined heat and mass balance equations provides temperature and pressure profiles inside the column, and values of the retention time and efficiency for elution of this unretained compound that are in excellent agreement with independent experimental data. Copyright © 2010 Elsevier B.V. All rights reserved.
Liang, Chao; Qiao, Jun-Qin; Lian, Hong-Zhen
2017-12-15
Reversed-phase liquid chromatography (RPLC) based octanol-water partition coefficient (logP) or distribution coefficient (logD) determination methods were revisited and assessed comprehensively. Classic isocratic and some gradient RPLC methods were conducted and evaluated for neutral, weak acid and basic compounds. Different lipophilicity indexes in logP or logD determination were discussed in detail, including the retention factor logk w corresponding to neat water as mobile phase extrapolated via linear solvent strength (LSS) model from isocratic runs and calculated with software from gradient runs, the chromatographic hydrophobicity index (CHI), apparent gradient capacity factor (k g ') and gradient retention time (t g ). Among the lipophilicity indexes discussed, logk w from whether isocratic or gradient elution methods best correlated with logP or logD. Therefore logk w is recommended as the preferred lipophilicity index for logP or logD determination. logk w easily calculated from methanol gradient runs might be the main candidate to replace logk w calculated from classic isocratic run as the ideal lipophilicity index. These revisited RPLC methods were not applicable for strongly ionized compounds that are hardly ion-suppressed. A previously reported imperfect ion-pair RPLC method was attempted and further explored for studying distribution coefficients (logD) of sulfonic acids that totally ionized in the mobile phase. Notably, experimental logD values of sulfonic acids were given for the first time. The IP-RPLC method provided a distinct way to explore logD values of ionized compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Nikitas, P; Pappa-Louisi, A
2005-09-01
The original work carried out by Freiling and Drake in gradient liquid chromatography is rewritten in the current language of reversed-phase liquid chromatography. This allows for the rigorous derivation of the fundamental equation for gradient elution and the development of two alternative expressions of this equation, one of which is free from the constraint that the holdup time must be constant. In addition, the above derivation results in a very simple numerical solution of the various equations of gradient elution under any gradient profile. The theory was tested using eight catechol-related solutes in mobile phases modified with methanol, acetonitrile, or 2-propanol. It was found to be a satisfactory prediction of solute gradient retention behavior even if we used a simple linear description for the isocratic elution of these solutes.
Jandera, Pavel; Vyňuchalová, Kateřina; Nečilová, Kateřina
2013-11-22
Combined effects of temperature and mobile-phase composition on retention and separation selectivity of phenolic acids and flavonoid compounds were studied in liquid chromatography on a polydentate Blaze C8 silica based column. The temperature effects on the retention can be described by van't Hoff equation. Good linearity of lnk versus 1/T graphs indicates that the retention is controlled by a single mechanism in the mobile phase and temperature range studied. Enthalpic and entropic contributions to the retention were calculated from the regression lines. Generally, enthalpic contributions control the retention at lower temperatures and in mobile phases with lower concentrations of methanol in water. Semi-empirical retention models describe the simultaneous effects of temperature and the volume fraction of the organic solvent in the mobile phase. Using the linear free energy-retention model, selective dipolarity/polarizability, hydrogen-bond donor, hydrogen-bond acceptor and molecular size contributions to retention were estimated at various mobile phase compositions and temperatures. In addition to mobile phase gradients, temperature programming can be used to reduce separation times. Copyright © 2013 Elsevier B.V. All rights reserved.
Balkatzopoulou, P; Fasoula, S; Gika, H; Nikitas, P; Pappa-Louisi, A
2015-05-29
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (lnk) upon the organic modifier volume fraction (φ). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
[Determination of sennosides and degraded products in the process of sennoside metabolism by HPLC].
Sun, Yan; Li, Xuetuo; Yu, Xingju
2004-01-01
A method for the separation and determination of sennosides A and B and the main composition (sennidins A and B) in degraded products of sennosides by linear gradient high performance liquid chromatography has been developed. Separation conditions were as follows: column, a Spherisorb C18 column (250 mm x 4.6 mm i.d., 10 microm); column temperature, 40 degrees C; detection wavelength, 360 nm; mobile phase A, 1.25% acetic acid aqueous solution; mobile phase B, methanol; linear gradient, 100% A --> (20 min) 100% B. The method is effective, quick, accurate and reproducible. The satisfactory results show that this new method has certain practical values as an approach of real-time analysis in the process of sennoside metabolism.
Advanced methods for preparation and characterization of infrared detector materials
NASA Technical Reports Server (NTRS)
Broerman, J. G.; Morris, B. J.; Meschter, P. J.
1983-01-01
Crystals were prepared by the Bridgman-Stockbarger method with a wide range of crystal growth rates and temperature gradients adequate to prevent constitutional supercooling under diffusion-limited, steady-state, growth conditions. The longitudinal compositional gradients for different growth conditions and alloy compositions were calculated and compared with experimental data to develop a quantitative model of solute redistribution during the crystal growth of the alloys. Measurements were performed to ascertain the effect of growth conditions on radial compositional gradients. The pseudobinary HgTe-CdTe constitutional phase diagram was determined by precision differential-thermal-analysis measurements and used to calculate the segregation coefficient of Cd as a function of x and interface temperature. Experiments were conducted to determine the ternary phase equilibria in selected regions of the Hg-Cd-Te constitutional phase diagram. Electron and hole mobilities as functions of temperature were analyzed to establish charge-carrier scattering probabilities. Computer algorithms specific to Hg(1-x)CdxTe were developed for calculations of the charge-carrier concentration, charge-carrier mobilities, Hall coefficient, and Dermi Fermi energy as functions of x, temperature, ionized donor and acceptor concentrations, and neutral defect concentrations.
NASA Astrophysics Data System (ADS)
Bretin, Elie; Danescu, Alexandre; Penuelas, José; Masnou, Simon
2018-07-01
The structure of many multiphase systems is governed by an energy that penalizes the area of interfaces between phases weighted by surface tension coefficients. However, interface evolution laws depend also on interface mobility coefficients. Having in mind some applications where highly contrasted or even degenerate mobilities are involved, for which classical phase field models are inapplicable, we propose a new effective phase field approach to approximate multiphase mean curvature flows with mobilities. The key aspect of our model is to incorporate the mobilities not in the phase field energy (which is conventionally the case) but in the metric which determines the gradient flow. We show the consistency of such an approach by a formal analysis of the sharp interface limit. We also propose an efficient numerical scheme which allows us to illustrate the advantages of the model on various examples, as the wetting of droplets on solid surfaces or the simulation of nanowires growth generated by the so-called vapor-liquid-solid method.
Reddy, Sunil Pingili; Babu, K Sudhakar; Kumar, Navneet; Sekhar, Y V V Sasi
2011-10-01
A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness.
Reddy, Sunil Pingili; Babu, K. Sudhakar; Kumar, Navneet; Sekhar, Y. V. V. Sasi
2011-01-01
Aim and background: A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. Materials and methods: The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Results: Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Conclusion: The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781462
Andrés, Axel; Rosés, Martí; Bosch, Elisabeth
2014-11-28
In previous work, a two-parameter model to predict chromatographic retention of ionizable analytes in gradient mode was proposed. However, the procedure required some previous experimental work to get a suitable description of the pKa change with the mobile phase composition. In the present study this previous experimental work has been simplified. The analyte pKa values have been calculated through equations whose coefficients vary depending on their functional group. Forced by this new approach, other simplifications regarding the retention of the totally neutral and totally ionized species also had to be performed. After the simplifications were applied, new prediction values were obtained and compared with the previously acquired experimental data. The simplified model gave pretty good predictions while saving a significant amount of time and resources. Copyright © 2014 Elsevier B.V. All rights reserved.
Cyclohexylamine additives for enhanced peptide separations in reversed phase liquid chromatography.
Cole, S R; Dorsey, J G
1997-01-01
While the choice of stationary phase, organic modifier, and gradient strength can have significant effects on biomolecule separations, mobile phase additives can also have a significant effect on the chromatographic selectivity, recovery, efficiency and resolution. Given the importance of stationary phase coverage, the beneficial, silanol-masking properties of amines, and the potential for selectivity modification through ion-pair interactions, cyclohexylamine was examined as a mobile phase additive and compared with triethylamine and trifluoroacetic acid. Greatly improved separation was possible when cyclohexylamine was used as compared with phosphate buffer, and cyclohexylamine did not require purification before use, while triethylamine required distillation before 'clean' chromatograms were obtained.
Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep
2015-01-01
A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation conditions for seven phenolic compounds was also achieved using reversed-phase HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and seven phenolic compounds could be separated and detected at 230 nm within 16 min. Copyright © 2014 Elsevier B.V. All rights reserved.
Atom interferometric gravity gradiometer: Disturbance compensation and mobile gradiometry
NASA Astrophysics Data System (ADS)
Mahadeswaraswamy, Chetan
First ever mobile gravity gradient measurement based on Atom Interferometric sensors has been demonstrated. Mobile gravity gradiometers play a significant role in high accuracy inertial navigation systems in order to distinguish inertial acceleration and acceleration due to gravity. The gravity gradiometer consists of two atom interferometric accelerometers. In each of the accelerometer an ensemble of laser cooled Cesium atoms is dropped and using counter propagating Raman pulses (pi/2-pi-pi/2) the ensemble is split into two states for carrying out atom interferometry. The interferometer phase is proportional to the specific force experienced by the atoms which is a combination of inertial acceleration and acceleration due to gravity. The difference in phase between the two atom interferometric sensors is proportional to gravity gradient if the platform does not undergo any rotational motion. However, any rotational motion of the platform induces spurious gravity gradient measurements. This apparent gravity gradient due to platform rotation is considerably different for an atom interferometric sensor compared to a conventional force rebalance type sensor. The atoms are in free fall and are not influenced by the motion of the case except at the instants of Raman pulses. A model for determining apparent gravity gradient due to rotation of platform was developed and experimentally verified for different frequencies. This transfer function measurement also lead to the development of a new technique for aligning the Raman laser beams with the atom clusters to within 20 mu rad. This gravity gradiometer is situated in a truck for the purpose of undertaking mobile surveys. A disturbance compensation system was designed and built in order to compensate for the rotational disturbances experienced on the floor of a truck. An electric drive system was also designed specifically to be able to move the truck in a uniform motion at very low speeds of about 1cm/s. A 250 x10-9 s-2 gravity gradient signature due to an underground void at Hansen Experimental Physics Building at Stanford was successfully measured using this mobile gradiometer.
Recursion equations in predicting band width under gradient elution.
Liang, Heng; Liu, Ying
2004-06-18
The evolution of solute zone under gradient elution is a typical problem of non-linear continuity equation since the local diffusion coefficient and local migration velocity of the mass cells of solute zones are the functions of position and time due to space- and time-variable mobile phase composition. In this paper, based on the mesoscopic approaches (Lagrangian description, the continuity theory and the local equilibrium assumption), the evolution of solute zones in space- and time-dependent fields is described by the iterative addition of local probability density of the mass cells of solute zones. Furthermore, on macroscopic levels, the recursion equations have been proposed to simulate zone migration and spreading in reversed-phase high-performance liquid chromatography (RP-HPLC) through directly relating local retention factor and local diffusion coefficient to local mobile phase concentration. This new approach differs entirely from the traditional theories on plate concept with Eulerian description, since band width recursion equation is actually the accumulation of local diffusion coefficients of solute zones to discrete-time slices. Recursion equations and literature equations were used in dealing with same experimental data in RP-HPLC, and the comparison results show that the recursion equations can accurately predict band width under gradient elution.
Simultaneous concentration and purification through gradient deformation chromatography
NASA Technical Reports Server (NTRS)
Velayudhan, A.; Hendrickson, R. L.; Ladisch, M. R.; Mitchell, C. A. (Principal Investigator)
1995-01-01
Mobile-phase additives, commonly used to modulate absorbate retention in gradient elution chromatography, are usually assumed to be either linearly retained or unretained. Previous theoretical work from our laboratory has shown that these modulators, such as salts in ion-exchange and hydrophobic interaction chromatography and organic modifiers in reversed-phase chromatography, can absorb nonlinearly, giving rise to gradient deformation. Consequently, adsorbate peaks that elute in the vicinity of the head of the deformed gradient may exhibit unusual shapes, form shoulders, and/or be concentrated. These effects for a reversed-phase sorbent with aqueous acetonitrile (ACN) as the modulator are verified experimentally. Gradient deformation is demonstrated experimentally and agrees with simulations based on ACN isotherm parameters that are independently determined from batch equilibrium studies using the layer model. Unusual absorbate peak shapes were found experimentally for single-component injections of phenylalanine, similar to those calculated by the simulations. A binary mixture of tryptophan and phenylalanine is used to demonstrate simultaneous concentration and separation, again in agreement with simulations. The possibility of gradient deformation in ion-exchange and hydrophobic interaction chromatography is discussed.
Tham, S Y; Agatonovic-Kustrin, S
2002-05-15
Quantitative structure-retention relationship(QSRR) method was used to model reversed-phase high-performance liquid chromatography (RP-HPLC) separation of 18 selected amino acids. Retention data for phenylthiocarbamyl (PTC) amino acids derivatives were obtained using gradient elution on ODS column with mobile phase of varying acetonitrile, acetate buffer and containing 0.5 ml/l of triethylamine (TEA). Molecular structure of each amino acid was encoded with 36 calculated molecular descriptors. The correlation between the molecular descriptors and the retention time of the compounds in the calibration set was established using the genetic neural network method. A genetic algorithm (GA) was used to select important molecular descriptors and supervised artificial neural network (ANN) was used to correlate mobile phase composition and selected descriptors with the experimentally derived retention times. Retention time values were used as the network's output and calculated molecular descriptors and mobile phase composition as the inputs. The best model with five input descriptors was chosen, and the significance of the selected descriptors for amino acid separation was examined. Results confirmed the dominant role of the organic modifier in such chromatographic systems in addition to lipophilicity (log P) and molecular size and shape (topological indices) of investigated solutes.
Kazarian, Artaches A; Taylor, Mark R; Haddad, Paul R; Nesterenko, Pavel N; Paull, Brett
2013-12-01
The comprehensive separation and detection of hydrophobic and hydrophilic active pharmaceutical ingredients (APIs), their counter-ions (organic, inorganic) and excipients, using a single mixed-mode chromatographic column, and a dual injection approach is presented. Using a mixed-mode Thermo Fisher Acclaim Trinity P1 column, APIs, their counter-ions and possible degradants were first separated using a combination of anion-exchange, cation-exchange and hydrophobic interactions, using a mobile phase consisting of a dual organic modifier/salt concentration gradient. A complementary method was also developed using the same column for the separation of hydrophilic bulk excipients, using hydrophilic interaction liquid chromatography (HILIC) under high organic solvent mobile phase conditions. These two methods were then combined within a single gradient run using dual sample injection, with the first injection at the start of the applied gradient (mixed-mode retention of solutes), followed by a second sample injection at the end of the gradient (HILIC retention of solutes). Detection using both ultraviolet absorbance and refractive index enabled the sensitive detection of APIs and UV-absorbing counter-ions, together with quantitative determination of bulk excipients. The developed approach was applied successfully to the analysis of a dry powder inhalers (Flixotide(®), Spiriva(®)), enabling comprehensive quantification of all APIs and excipients in the sample. Copyright © 2013 Elsevier B.V. All rights reserved.
Rodriguez-Aller, Marta; Guillarme, Davy; Beck, Alain; Fekete, Szabolcs
2016-01-25
The goal of this work is to provide some recommendations for method development in HIC using monoclonal antibodies (mAbs) and antibody-drug conjugates (ADCs) as model drug candidates. The effects of gradient steepness, mobile phase pH, salt concentration and type, as well as organic modifier were evaluated for tuning selectivity and retention in HIC. Except the nature of the stationary phase, which was not discussed in this study, the most important parameter for modifying selectivity was the gradient steepness. The addition of organic solvent (up to 15% isopropanol) in the mobile phase was also found to be useful for mAbs analysis, since it could provide some changes in elution order, in some cases. On the contrary, isopropanol was not beneficial with ADCs, since the most hydrophobic DAR species (DAR6 and DAR8) cannot be eluted from the stationary phase under these conditions. This study also illustrates the possibility to perform HIC method development using optimization software, such as Drylab. The optimum conditions suggested by the software were tested using therapeutic mAbs and commercial cysteine linked ADC (brentuximab-vedotin) and the average retention time errors between predicted and experimental retention times were ∼ 1%. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaczmarski, Krzysztof; Guiochon, Georges A
2011-01-01
In supercritical fluid chromatography (SFC), the significant expansion of the mobile phase along the column causes the formation of axial and radial gradients of temperature. Due to these gradients, the mobile phase density, its viscosity, its velocity, its diffusion coefficients, etc. are not constant throughout the column. This results in a nonuniform flow velocity distribution, itself causing a loss of column efficiency in certain cases, even at low flow rates, as they do in HPLC. At high flow rates, an important deformation of the elution profiles of the sample components may occur. The model previously used to account satisfactorily formore » the retention of an unsorbed solute in SFC is applied to the modeling of the elution peak profiles of retained compounds. The numerical solution of the combined heat and mass balance equations provides the temperature and the pressure profiles inside the column and values of the retention time and the band profiles of retained compounds that are in excellent agreement with independent experimental data for large value of mobile phase reduced density. At low reduced densities, the band profiles can strongly depend on the column axial distribution of porosity.« less
Jandera, Pavel; Hájek, Tomáš
2018-01-01
Hydrophilic interaction liquid chromatography on polar columns in aqueous-organic mobile phases has become increasingly popular for the separation of many biologically important compounds in chemical, environmental, food, toxicological, and other samples. In spite of many new applications appearing in literature, the retention mechanism is still controversial. This review addresses recent progress in understanding of the retention models in hydrophilic interaction liquid chromatography. The main attention is focused on the role of water, both adsorbed by the column and contained in the bulk mobile phase. Further, the theoretical retention models in the isocratic and gradient elution modes are discussed. The dual hydrophilic interaction liquid chromatography reversed-phase retention mechanism on polar columns is treated in detail, especially with respect to the practical use in one- and two-dimensional liquid chromatography separations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
West, Caroline; Melin, Jodie; Ansouri, Hassna; Mengue Metogo, Maïly
2017-04-07
The mobile phases employed in current supercritical fluid chromatography (SFC) are usually composed of a mixture of pressurized carbon dioxide and a co-solvent. The co-solvent is most often an alcohol and may contain a third component in small proportions, called an additive (acid, base or salt). The polarity of such mobile phase compositions is here re-evaluated with a solvatochromic dye (Nile Red), particularly to assess the contribution of additives. It appears that additives, when employed in usual concentration range (0.1% or 20mM) do not modify the polarity in the immediate environment of the probe. In addition, the combination of carbon dioxide and an alcohol is known to form alkoxylcarbonic acid, supposedly conferring some acidic character to SFC mobile phases. Direct measurements of the apparent pH are impossible, but colour indicators of pH can be used to define the range of apparent pH provided by carbon dioxide-alcohol mixtures, with or without additives. Five colour indicators (Thymol Blue, Bromocresol Green, Methyl Red, Bromocresol Purple, and Bromothymol Blue) were selected to provide a wide range of aqueous pK a values (from 1.7 to 8.9). UV-vis absorption spectra measured in liquid phases of controlled pH were compared to those measured with a diode-array detector employed in SFC, with the help of chemometric methods. Based on these observations, it is concluded that the apparent pH range in carbon dioxide-methanol mobile phases is close to 5. Increasing the proportion of methanol (in the course of a gradient elution for instance) causes decreasing apparent pH. Strong acids can further decrease the apparent pH below 1.7; strong bases have little influence on the apparent pH, probably because, in this range of concentrations, they are titrated by alkoxylcarbonic acid or form ion pairs with alkoxycarbonate. However, bases and salts could stabilize the acidity in the course of gradient runs. Copyright © 2017 Elsevier B.V. All rights reserved.
Pappa-Louisi, A; Agrafiotou, P; Papachristos, K
2010-07-01
The combined effect of the ion-pairing reagent concentration, C(ipr), and organic modifier content, phi, on the retention under phi-gradient conditions at different constant C(ipr) was treated in this study by using two approaches. In the first approach, the prediction of the retention time of a sample solute is based on a direct fitting procedure of a proper retention model to 3-D phi-gradient retention data obtained under the same phi-linear variation but with different slope and time duration of the initial isocratic part and in the presence of various constant C(ipr) values in the eluent. The second approach is based on a retention model describing the combined effect of C(ipr) and phi on the retention of solutes in isocratic mode and consequently analyzes isocratic data obtained in mobile phases containing different C(ipr) values. The effectiveness of the above approaches was tested in the retention prediction of a mixture of 16 underivatized amino acids using mobile phases containing acetonitrile as organic modifier and sodium dodecyl sulfate as ion-pairing reagent. From these approaches, only the first one gives satisfactory predictions and can be successfully used in optimization of ion-pair chromatographic separations under gradient conditions. The failure of the second approach to predict the retention of solutes in the gradient elution mode in the presence of different C(ipr) values was attributed to slow changes in the distribution equilibrium of ion-pairing reagents caused by phi-variation.
Chen, Kai; Lynen, Frédéric; De Beer, Maarten; Hitzel, Laure; Ferguson, Paul; Hanna-Brown, Melissa; Sandra, Pat
2010-11-12
Stationary phase optimized selectivity liquid chromatography (SOSLC) is a promising technique to optimize the selectivity of a given separation by using a combination of different stationary phases. Previous work has shown that SOSLC offers excellent possibilities for method development, especially after the recent modification towards linear gradient SOSLC. The present work is aimed at developing and extending the SOSLC approach towards selectivity optimization and method development for green chromatography. Contrary to current LC practices, a green mobile phase (water/ethanol/formic acid) is hereby preselected and the composition of the stationary phase is optimized under a given gradient profile to obtain baseline resolution of all target solutes in the shortest possible analysis time. With the algorithm adapted to the high viscosity property of ethanol, the principle is illustrated with a fast, full baseline resolution for a randomly selected mixture composed of sulphonamides, xanthine alkaloids and steroids. Copyright © 2010 Elsevier B.V. All rights reserved.
Bacterial chemotaxis along vapor-phase gradients of naphthalene.
Hanzel, Joanna; Harms, Hauke; Wick, Lukas Y
2010-12-15
The role of bacterial growth and translocation for the bioremediation of organic contaminants in the vadose zone is poorly understood. Whereas air-filled pores restrict the mobility of bacteria, diffusion of volatile organic compounds in air is more efficient than in water. Past research, however, has focused on chemotactic swimming of bacteria along gradients of water-dissolved chemicals. In this study we tested if and to what extent Pseudomonas putida PpG7 (NAH7) chemotactically reacts to vapor-phase gradients forming above their swimming medium by the volatilization from a spot source of solid naphthalene. The development of an aqueous naphthalene gradient by air-water partitioning was largely suppressed by means of activated carbon in the agar. Surprisingly, strain PpG7 was repelled by vapor-phase naphthalene although the steady state gaseous concentrations were 50-100 times lower than the aqueous concentrations that result in positive chemotaxis of the same strain. It is thus assumed that the efficient gas-phase diffusion resulting in a steady, and possibly toxic, naphthalene flux to the cells controlled the chemotactic reaction rather than the concentration to which the cells were exposed. To our knowledge this is the first demonstration of apparent chemotactic behavior of bacteria in response to vapor-phase effector gradients.
Liu, Dan; Ma, Yan; Wang, Ye; Su, Zhiguo; Gu, Ming; Janson, Jan-Christer
2011-05-01
The hydrolysable tannins corilagin and geraniin, the major active components of the traditional Chinese medicine Geranium wilfordii Maxim, have been separated and purified from crude extracts in one step by adsorption chromatography on cross-linked 12% agarose gel (Superose 12 10/300 GL). The separation was achieved by gradient elution using mobile phase A composed of 5% ethanol and 5% acetic acid and mobile phase B composed of 30% ethanol and 30% acetic acid. The gradients were composed as follows: 0-240 mL, 0-25% B; 240-480 mL, 25-40% B; after 480 mL, 100% B. The purities of the collected corilagin and geraniin were 92.4 and 87.2%, and the corresponding yields were 88.0 and 76.8%, respectively. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effects of wave shape on sheet flow sediment transport
Hsu, T.-J.; Hanes, D.M.
2004-01-01
A two-phase model is implemented to study the effects of wave shape on the transport of coarse-grained sediment in the sheet flow regime. The model is based on balance equations for the average mass, momentum, and fluctuation energy for both the fluid and sediment phases. Model simulations indicate that the responses of the sheet flow, such as the velocity profiles, the instantaneous bed shear stress, the sediment flux, and the total amount of the mobilized sediment, cannot be fully parameterized by quasi-steady free-stream velocity and may be correlated with the magnitude of local horizontal pressure gradient (or free-stream acceleration). A net sediment flux in the direction of wave advance is obtained for both skewed and saw-tooth wave shapes typical of shoaled and breaking waves. The model further suggests that at critical values of the horizontal pressure gradient, there is a failure event within the bed that mobilizes more sediment into the mobile sheet and enhances the sediment flux. Preliminary attempts to parameterize the total bed shear stress and the total sediment flux appear promising. Copyright 2004 by the American Geophysical Union.
Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr
2010-05-23
This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg mL(-1) for paracetamol, at 0.5 microg mL(-1) for caffeine and at 0.7 microg mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). Copyright 2010 Elsevier B.V. All rights reserved.
Li, Wei; Wang, Jun; Yan, Zheng-Yu
2015-10-10
A novel simple, fast and efficient supercritical fluid chromatography (SFC) method was developed and compared with RPLC method for the separation and determination of impurities in rifampicin. The separation was performed using a packed diol column and a mobile phase B (modifier) consisting of methanol with 0.1% ammonium formate (w/v) and 2% water (v/v). Overall satisfactory resolutions and peak shapes for rifampicin quinone (RQ), rifampicin (RF), rifamycin SV (RSV), rifampicin N-oxide (RNO) and 3-formylrifamycinSV (3-FR) were obtained by optimization of the chromatography system. With gradient elution of mobile phase, all of the impurities and the active were separated within 4 min. Taking full advantage of features of SFC (such as particular selectivity, non-sloping baseline in gradient elution, and without injection solvent effects), the method was successfully used for determination of impurities in rifampicin, with more impurity peaks detected, better resolution achieved and much less analysis time needed compared with conventional reversed-phase liquid chromatography (RPLC) methods. Copyright © 2015 Elsevier B.V. All rights reserved.
High throughput screening of active pharmaceutical ingredients by UPLC.
Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun
2008-07-01
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.
Mallik, Rangan; Raman, Srividya; Liang, Xiaoli; Grobin, Adam W; Choudhury, Dilip
2015-09-25
A rapid robust reversed-phase UHPLC method has been developed for the analysis of total benzalkonium chloride in preserved drug formulation. A systematic Quality-by-Design (QbD) method development approach using commercial, off the shelf software (Fusion AE(®)) has been used to optimize the column, mobile phases, gradient time, and other HPLC conditions. Total benzalkonium chloride analysis involves simple sample preparation. The method uses gradient elution from an ACE Excel 2 C18-AR column (50mm×2.1mm, 2.0μm particle size), ammonium phosphate buffer (pH 3.3; 10mM) as aqueous mobile phase and methanol/acetonitrile (85/15, v/v) as the organic mobile phase with UV detection at 214nm. Using these conditions, major homologs of the benzalkonium chloride (C12 and C14) have been separated in less than 2.0min. The validation results confirmed that the method is precise, accurate and linear at concentrations ranging from 0.025mg/mL to 0.075mg/mL for total benzalkonium chloride. The recoveries ranged from 99% to 103% at concentrations from 0.025mg/mL to 0.075mg/mL for total benzalkonium chloride. The validation results also confirmed the robustness of the method as predicted by Fusion AE(®). Copyright © 2015 Elsevier B.V. All rights reserved.
Teutenberg, T; Goetze, H-J; Tuerk, J; Ploeger, J; Kiffmeyer, T K; Schmidt, K G; Kohorst, W gr; Rohe, T; Jansen, H-D; Weber, H
2006-05-05
A specially designed heating system for temperature-programmed HPLC was developed based on experimental measurements of eluent temperature inside a stainless steel capillary using a very thin thermocouple. The heating system can be operated at temperatures up to 225 degrees C and consists of a preheating, a column heating and a cooling unit. Fast cycle times after a temperature gradient can be realized by an internal silicone oil bath which cools down the preheating and column heating unit. Long-term thermal stability of a polybutadiene-coated zirconium dioxide column has been evaluated using a tubular oven in which the column was placed. The packing material was stable after 50h of operation at 185 degrees C. A mixture containing four steroids was separated at ambient conditions using a mobile phase of 25% acetonitrile:75% deionized water and a mobile phase of pure deionized water at 185 degrees C using the specially designed heating system and the PBD column. Analysis time could be drastically reduced from 17 min at ambient conditions and a flow rate of 1 mL/min to only 1.2 min at 185 degrees C and a flow rate of 5 mL/min. At these extreme conditions, no thermal mismatch was observed and peaks were not distorted, thus underlining the performance of the developed heating system. Temperature programming was performed by separating cytostatic and antibiotic drugs with a temperature gradient using only water as the mobile phase. In contrast to an isocratic elution of this mixture at room temperature, overall analysis time could be reduced two-fold from 20 to 10 min.
Pore-scale mechanisms of gas flow in tight sand reservoirs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silin, D.; Kneafsey, T.J.; Ajo-Franklin, J.B.
2010-11-30
Tight gas sands are unconventional hydrocarbon energy resource storing large volume of natural gas. Microscopy and 3D imaging of reservoir samples at different scales and resolutions provide insights into the coaredo not significantly smaller in size than conventional sandstones, the extremely dense grain packing makes the pore space tortuous, and the porosity is small. In some cases the inter-granular void space is presented by micron-scale slits, whose geometry requires imaging at submicron resolutions. Maximal Inscribed Spheres computations simulate different scenarios of capillary-equilibrium two-phase fluid displacement. For tight sands, the simulations predict an unusually low wetting fluid saturation threshold, at whichmore » the non-wetting phase becomes disconnected. Flow simulations in combination with Maximal Inscribed Spheres computations evaluate relative permeability curves. The computations show that at the threshold saturation, when the nonwetting fluid becomes disconnected, the flow of both fluids is practically blocked. The nonwetting phase is immobile due to the disconnectedness, while the permeability to the wetting phase remains essentially equal to zero due to the pore space geometry. This observation explains the Permeability Jail, which was defined earlier by others. The gas is trapped by capillarity, and the brine is immobile due to the dynamic effects. At the same time, in drainage, simulations predict that the mobility of at least one of the fluids is greater than zero at all saturations. A pore-scale model of gas condensate dropout predicts the rate to be proportional to the scalar product of the fluid velocity and pressure gradient. The narrowest constriction in the flow path is subject to the highest rate of condensation. The pore-scale model naturally upscales to the Panfilov's Darcy-scale model, which implies that the condensate dropout rate is proportional to the pressure gradient squared. Pressure gradient is the greatest near the matrix-fracture interface. The distinctive two-phase flow properties of tight sand imply that a small amount of gas condensate can seriously affect the recovery rate by blocking gas flow. Dry gas injection, pressure maintenance, or heating can help to preserve the mobility of gas phase. A small amount of water can increase the mobility of gas condensate.« less
Expanding the term "Design Space" in high performance liquid chromatography (I).
Monks, K E; Rieger, H-J; Molnár, I
2011-12-15
The current article presents a novel approach to applying Quality by Design (QbD) principles to the development of high pressure reversed phase liquid chromatography (HPLC) methods. Four common critical parameters in HPLC--gradient time, temperature, pH of the aqueous eluent, and stationary phase--are evaluated within the Quality by Design framework by the means of computer modeling software and a column database, to a satisfactory degree. This work proposes the establishment of two mutually complimentary Design Spaces to fully depict a chromatographic method; one Column Design Space (CDS) and one Eluent Design Space (EDS) to describe the influence of the stationary phase and of the mobile phase on the separation selectivity, respectively. The merge of both Design Spaces into one is founded on the continuous nature of the mobile phase influence on retention and the great variety of the stationary phases available. Copyright © 2011 Elsevier B.V. All rights reserved.
Zhang, Min; Chen, Apeng; Lu, Joann J; Cao, Chengxi; Liu, Shaorong
2016-08-19
In micro- or nano-flow high performance liquid chromatography (HPLC), flow-splitters and gradient elutions are commonly used for reverse phase HPLC separations. When a flow splitter was used at a high split-ratio (e.g., 1000:1 or higher), the actual gradient may deviate away from the programmed gradient. Sometimes, mobile phase concentrations can deviate by as much as 5%. In this work, we noticed that the conductivity (σ) of a gradient decreased with the increasing organic-solvent fraction (φ). Based on the relationship between σ and φ, a method was developed for monitoring gradient profile on-line to record any deviations in these HPLC systems. The conductivity could be measured by a traditional conductivity detector or a capacitively coupled contactless conductivity detector (C(4)D). The method was applied for assessing the performance of an electroosmotic pump (EOP) based nano-HPLC. We also observed that σ value of the gradient changed with system pressure; a=0.0175ΔP (R(2)=0.964), where a is the percentage of the conductivity increase and ΔP is the system pressure in bar. This effect was also investigated. Copyright © 2016. Published by Elsevier B.V.
Ortín, A; Torres-Lapasió, J R; García-Álvarez-Coque, M C
2011-08-26
Situations of minimal resolution are often found in liquid chromatography, when samples that contain a large number of compounds, or highly similar in terms of structure and/or polarity, are analysed. This makes full resolution with a single separation condition (e.g., mobile phase, gradient or column) unfeasible. In this work, the optimisation of the resolution of such samples in reversed-phase liquid chromatography is approached using two or more isocratic mobile phases with a complementary resolution behaviour (complementary mobile phases, CMPs). Each mobile phase is dedicated to the separation of a group of compounds. The CMPs are selected in such a way that, when the separation is considered globally, all the compounds in the sample are satisfactorily resolved. The search of optimal CMPs can be carried out through a comprehensive examination of the mobile phases in a selected domain. The computation time of this search has been reported to be substantially reduced by application of a genetic algorithm with local search (LOGA). A much simpler approach is here described, which is accessible to non-experts in programming, and offers solutions of the same quality as LOGA, with a similar computation time. The approach makes a sequential search of CMPs based on the peak count concept, which is the number of peaks exceeding a pre-established resolution threshold. The new approach is described using as test sample a mixture of 30 probe compounds, 23 of them with an ionisable character, and the pH and organic solvent contents as experimental factors. Copyright © 2011 Elsevier B.V. All rights reserved.
Cimpoiu, Claudia; Hosu, Anamaria; Puscas, Anitta
2012-02-03
The group of hydrophilic vitamins play an important role in human health, and their lack or excess produces specific diseases. Therefore, the analysis of these compounds is indispensable for monitoring their content in pharmaceuticals and food in order to prevent some human diseases. TLC was successfully applied in the analysis of hydrophilic vitamins, but the most difficult problem in the simultaneous analysis of all these compounds is to find an optimum stationary phase-mobile phase system due to different chemical characteristics of analytes. Unfortunately structural analogues are difficult to separate in one chromatographic run, and this is the case in hydrophilic vitamins investigations. TLC gives the possibility to perform two-dimensional separations by using stationary phase gradient achieving the highest resolution by combining two systems with different selectivity. The goal of this work was to develop a method of analysis enabling separation of hydrophilic vitamins using TLC with adsorbent gradient. The developed method was used for identifying the water-soluble vitamins in alcoholic extracts of Hippophae rhamnoides and of Ribes nigrum. Copyright © 2011 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The UHPLC-QToF-MS analysis of pyrrolizidine alkaloids from various parts of 37 botanicals and 7 dietary supplements was performed. A separation by LC was achieved using a reversed-phase column and a gradient of water/acetonitrile each containing formic acid as the mobile phase. MS-MS detection was u...
Krishnaiah, Ch; Sri, Khagga Bhavya
2012-05-01
A simple, selective and sensitive gradient reversed-phase liquid chromatography method has been developed for the separation and determination of 2,3-dichlorobenzoic acid, which is an intermediate of the lamotrizine drug substance, and its regio isomers. The separation was achieved on a reversed-phase United States Pharmacopeia L1 (C-18) column using 0.01 M ammonium acetate buffer at pH 2.5 and methanol (50:50 v/v) mixture as mobile phase A and a methanol and water mixture (80:20 v/v) as mobile phase B in a gradient elution at flow rate 1.2 mL/min with ultraviolet detection at 210 nm. The method is found to be selective, precise, linear, accurate and robust. It was used for quality assurance and monitoring the synthetic reactions involved in the process development of lamotrizine. The method is found to be simple, rapid, specific and reliable for the determination of unreacted levels of raw materials and isomers in reaction mixtures and finished product lamotrizine. The method was fully validated as per International Conference of Harmonization guidelines and results from validation confirm that the method is highly suitable for its intended purpose. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Amezcua-Allieri, M A; Rodríguez-Vázquez, R
2006-03-01
To study the impact of fungal bioremediation of phenanthrene on trace cadmium solid-solution fluxes and solution phase concentration. The bioremediation of phenanthrene in soils was performed using the fungus Penicillium frequentans. Metal behaviour was evaluated by the techniques of diffusive gradient in thin-films (DGT) and filtration. Fluxes of cadmium (Cd) show a significant (P < 0.002) increase after the start of bioremediation, indicating that the bioremediation process itself releases significant amount of Cd into solution from the soil solid-phase. Unlike DGT devices, the solution concentration from filtration shows a clear bimodal distribution. We postulate that the initial action of the fungi is most likely to breakdown the surface of the solid phase to smaller, 'solution-phase' material (<0.45 microm) leading to a peak in Cd concentration in solution. Phenanthrene removal from soils by bioremediation ironically results in the mobilization of another toxic pollutant (Cd). Bioremediation of organic pollutants in contaminated soil will likely lead to large increases in the mobilization of toxic metals, increasing metal bio-uptake and incorporation into the wider food chain. Bioremediation strategies need to account for this behaviour and further research is required both to understand the generality of this behaviour and the operative mechanisms.
Dias, M Graça; Oliveira, Luísa; Camões, M Filomena G F C; Nunes, Baltazar; Versloot, Pieter; Hulshof, Paul J M
2010-05-21
Three sets of extraction/saponification/HPLC conditions for food carotenoid quantification were technically and economically compared. Samples were analysed for carotenoids alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein, lycopene, and zeaxanthin. All methods demonstrated good performance in the analysis of a composite food standard reference material for the analytes they are applicable to. Methods using two serial connected C(18) columns and a mobile phase based on acetonitrile, achieved a better carotenoid separation than the method using a mobile phase based on methanol and one C(18)-column. Carotenoids from leafy green vegetable matrices appeared to be better extracted with a mixture of methanol and tetrahydrofuran than with tetrahydrofuran alone. Costs of carotenoid determination in foods were lower for the method with mobile phase based on methanol. However for some food matrices and in the case of E-Z isomer separations, this was not technically satisfactory. Food extraction with methanol and tetrahydrofuran with direct evaporation of these solvents, and saponification (when needed) using pyrogallol as antioxidant, combined with a HPLC system using a slight gradient mobile phase based on acetonitrile and a stationary phase composed by two serial connected C(18) columns was the most technically and economically favourable method. 2010. Published by Elsevier B.V.
Fang, N; Hou, S; Shao, X; He, Y; Zhao, G
1998-09-01
In this paper, reversed-phase high performance liquid chromatographic technique was used for the separation and determination of eight plant hormones. Methanol-water-acetic acid system was chosen as the mobile phase. The effects of different separation conditions, such as the methanol and acetic acid concentrations in mobile phase, on the retention behaviours of eight plant hormones in this system were studied. The general trends in retention behaviours could be correlated to the methanol concentration in mobile phase. The experimental results showed that the optimum separation was achieved with following gradient elution condition: 0-3 minutes, 70% (water percentage in mobile phase), 3-13 minutes, 70%-20%, 13-48 minutes, 20%. Benzene was added to be as the internal standard. Under this experimental condition, the eight plant hormones could be separated completely and detected quantitatively at 260 nm within 16 minutes. The calibration curves for the eight compounds gave linearity over a wide range. The correlation coefficients of each components were r(ZT) = 0.9971, r(GAs) = 0.9999, r(K) = 0.9997, r(BA) = 0.9995, r(IAA) = 0.9998, r(IPA) = 0.9982, r(IBA) = 0.9995 and r(NAA) = 0.9995. The method is rapid, simple and efficient. It is a suitable method for the accurate determination of gibberellic acid (GA) and alpha-naphthaleneacetic acid (alpha-NAA) in products for agricultural use.
Mommen, Geert P M; Meiring, Hugo D; Heck, Albert J R; de Jong, Ad P J M
2013-07-16
In proteomics, comprehensive analysis of peptides mixtures necessitates multiple dimensions of separation prior to mass spectrometry analysis to reduce sample complexity and increase the dynamic range of analysis. The main goal of this work was to improve the performance of (online) multidimensional protein identification technology (MudPIT) in terms of sensitivity, compatibility and recovery. The method employs weak anion and strong cation mixed-bed ion exchange chromatography (ACE) in the first separation dimension and reversed phase chromatography (RP) in the second separation dimension (Motoyama et.al. Anal. Chem 2007, 79, 3623-34.). We demonstrated that the chromatographic behavior of peptides in ACE chromatography depends on both the WAX/SCX mixing ratio as the ionic strength of the mobile phase system. This property allowed us to replace the conventional salt gradient by a (discontinuous) salt-free, pH gradient. First dimensional separation of peptides was accomplished with mixtures of aqueous formic acid and dimethylsulfoxide with increasing concentrations. The overall performance of this mobile phase system was found comparable to ammonium acetate buffers in application to ACE chromatography, but clearly outperformed strong cation exchange for use in first dimensional peptide separation. The dramatically improved compatibility between (salt-free) ion exchange chromatography and reversed phase chromatography-mass spectrometry allowed us to downscale the dimensions of the RP analytical column down to 25 μm i.d. for an additional 2- to 3-fold improvement in performance compared to current technology. The achieved levels of sensitivity, orthogonality, and compatibility demonstrates the potential of salt-free ACE MudPIT for the ultrasensitive, multidimensional analysis of very modest amounts of sample material.
Shen, Guoxiang; Hong, Jin-Liern; Kong, Ah-Ng Tony
2007-06-01
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.
Hynninen, P H; Räisänen, R
2001-01-01
Preparative-scale separation of substituted anthraquinones by multiple liquid-liquid partition was studied using isopropylmethyl ketone (IMK)/aqueous phosphate buffer (aq.) as the solvent system and the Hietala apparatus with 100 partition units as the partition equipment. The lower (aq.) phase was chosen as mobile, while the upper (IMK) phase remained stationary. Hence, the principle of stepwise pH-gradient elution could be utilized to separate the components in two complex mixtures of hydroxyanthraquinones and hydroxyanthraquinone carboxylic acids, isolated from the fungus Dermocybe sanguinea. In spite of the nonlinearity of the partition isotherms for these anthraquinones, implying deviations from the Nernst partition law, remarkable separations were achieved for the components in each mixture. Every anthraquinone carboxylic acid showed markedly irregular partition behavior, appearing in the effluent as two more or less resolved concentration zones. Such splitting was attributed to the formation of relatively stable sandwich-dimers, which were in a slow equilibrium with the monomers in the more nonpolar organic phase. At lower pH-values, only the polar monomers were distributed into the mobile aqueous phase and moved forward, whereas the nonpolar sandwich-dimers remained almost entirely in the stationary organic phase and lagged behind. When the pH of the mobile aqueous phase was raised high enough, the firmly linked dimers were monomerized and emerged from the apparatus as a second concentration profile. Intermolecular hydrogen bonding and pi-pi interaction between the pi-systems of two anthraquinone molecules in a parallel orientation were considered responsible for the nonlinear and markedly irregular partition behavior of the natural anthraquinones studied. The nonlinearity of the partition behavior of the hydroxyanthraquinones lacking the carboxyl group, appeared merely as excessive broadening of the experimental concentration profile, which impaired the resolution between the components only insignificantly. Thus, e.g. the main components, dermocybin and emodin, could both be obtained from Separation 1 in a purity of at least 99%.
Effect of modulator sorption on gradient shape in ion-exchange chromatography
NASA Technical Reports Server (NTRS)
Velayudhan, A.; Ladisch, M. R.; Mitchell, C. A. (Principal Investigator)
1995-01-01
Mobile phase additives, or modulators, are used in gradient elution chromatography to facilitate separation and reduce separation time. The modulators are usually assumed to be linearly adsorbed or unadsorbed. Here, the consequences of nonlinear modulator adsorption are examined for ion-exchange gradient elution through a series of simulations. Even when the buffer salt is identical to the modulator salt, gradient deformation is observed; the extent of deformation increases as the volume of the feed is increased. When the modulator salt is different from the buffer salt, unusual effects are observed, and the chromatograms are quite different from those predicted by classical gradient elution theory. In particular, local increases in the buffer concentration are found between feed bands, and serve to improve the separation. These effects become more pronounced as the feed volume increases, and could therefore prove valuable in preparative applications.
Nakamura, Tatsuji; Kuromitsu, Junro; Oda, Yoshiya
2008-03-01
Two-dimensional liquid-chromatographic (LC) separation followed by mass spectrometric (MS) analysis was examined for the identification of peptides in complex mixtures as an alternative to widely used two-dimensional gel electrophoresis followed by MS analysis for use in proteomics. The present method involves the off-line coupling of a narrow-bore, polymer-based, reversed-phase column using an acetonitrile gradient in an alkaline mobile phase in the first dimension with octadecylsilanized silica (ODS)-based nano-LC/MS in the second dimension. After the first separation, successive fractions were acidified and dried off-line, then loaded on the second dimension column. Both columns separate peptides according to hydrophobicity under different pH conditions, but more peptides were identified than with the conventional technique for shotgun proteomics, that is, the combination of a strong cation exchange column with an ODS column, and the system was robust because no salts were included in the mobile phases. The suitability of the method for proteomics measurements was evaluated.
Wang, Nu; Boswell, Paul G
2017-10-20
Gradient retention times are difficult to project from the underlying retention factor (k) vs. solvent composition (φ) relationships. A major reason for this difficulty is that gradients produced by HPLC pumps are imperfect - gradient delay, gradient dispersion, and solvent mis-proportioning are all difficult to account for in calculations. However, we recently showed that a gradient "back-calculation" methodology can measure these imperfections and take them into account. In RPLC, when the back-calculation methodology was used, error in projected gradient retention times is as low as could be expected based on repeatability in the k vs. φ relationships. HILIC, however, presents a new challenge: the selectivity of HILIC columns drift strongly over time. Retention is repeatable in short time, but selectivity frequently drifts over the course of weeks. In this study, we set out to understand if the issue of selectivity drift can be avoid by doing our experiments quickly, and if there any other factors that make it difficult to predict gradient retention times from isocratic k vs. φ relationships when gradient imperfections are taken into account with the back-calculation methodology. While in past reports, the accuracy of retention projections was >5%, the back-calculation methodology brought our error down to ∼1%. This result was 6-43 times more accurate than projections made using ideal gradients and 3-5 times more accurate than the same retention projections made using offset gradients (i.e., gradients that only took gradient delay into account). Still, the error remained higher in our HILIC projections than in RPLC. Based on the shape of the back-calculated gradients, we suspect the higher error is a result of prominent gradient distortion caused by strong, preferential water uptake from the mobile phase into the stationary phase during the gradient - a factor our model did not properly take into account. It appears that, at least with the stationary phase we used, column distortion is an important factor to take into account in retention projection in HILIC that is not usually important in RPLC. Copyright © 2017 Elsevier B.V. All rights reserved.
LIQUID CHROMATOGRAPHY DETERMINATION OF ANTI-ANDROGEN VINCLOZOLIN AND ITS METABOLITES IN RAT SERUM
The objective of this study was to develop a chromatographic method for the analysis of the anti-androgen vinclozolin (V) and its butenoic acid (M1) and enanilide (M2) metabolites in rat serum. V, M1, M2 and M3 were resolved using an HPLC gradient program with a mobile phase con...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Ahmad, S; Alsbou, N
Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embeddedmore » into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Ahmad, S; Alsbou, N
Purpose: To develop 4D-cone-beam CT (CBCT) algorithm by motion modeling that extracts actual length, CT numbers level and motion amplitude of a mobile target retrospective to image reconstruction by motion modeling. Methods: The algorithm used three measurable parameters: apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine actual length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm were tested with mobile targets that with different well-known sizes made from tissue-equivalent gel which was inserted into a thorax phantom. The phantom moved sinusoidally in one-direction to simulatemore » respiratory motion using eight amplitudes ranging 0–20mm. Results: Using this 4D-CBCT algorithm, three unknown parameters were extracted that include: length of the target, CT number level, speed or motion amplitude for the mobile targets retrospective to image reconstruction. The motion algorithms solved for the three unknown parameters using measurable apparent length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on the actual target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, actual target length and motion amplitude. Motion frequency and phase did not affect the elongation and CT number distribution of the mobile target and could not be determined. Conclusion: A 4D-CBCT motion algorithm was developed to extract three parameters that include actual length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement to motion tracking and sorting of the images into different breathing phases which has potential applications in diagnostic CT imaging and radiotherapy.« less
Alsbou, Nesreen; Ahmad, Salahuddin; Ali, Imad
2016-05-17
A motion algorithm has been developed to extract length, CT number level and motion amplitude of a mobile target from cone-beam CT (CBCT) images. The algorithm uses three measurable parameters: Apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm are tested with mobile targets having different well-known sizes that are made from tissue-equivalent gel which is inserted into a thorax phantom. The phantom moves sinusoidally in one-direction to simulate respiratory motion using eight amplitudes ranging 0-20 mm. Using this motion algorithm, three unknown parameters are extracted that include: Length of the target, CT number level, speed or motion amplitude for the mobile targets from CBCT images. The motion algorithm solves for the three unknown parameters using measured length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agrees with the measured lengths which are dependent on the target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, the target length and motion amplitude. Motion frequency and phase do not affect the elongation and CT number distribution of the mobile target and could not be determined. A motion algorithm has been developed to extract three parameters that include length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement of motion tracking and sorting of the images into different breathing phases. The motion model developed here works well for tumors that have simple shapes, high contrast relative to surrounding tissues and move nearly in regular motion pattern that can be approximated with a simple sinusoidal function. This algorithm has potential applications in diagnostic CT imaging and radiotherapy in terms of motion management.
Giegold, Sascha; Teutenberg, Thorsten; Tuerk, Jochen; Kiffmeyer, Thekla; Wenclawiak, Bernd
2008-10-01
A fast HPLC method for the analysis of eight selected sulfonamides (SA) and trimethoprim has been developed with the use of high temperature HPLC. The separation could be achieved in less than 1.5 min on a 50 mm sub 2 microm column with simultaneous solvent and temperature gradient programming. Due to the lower viscosity of the mobile phase and the increased mass transfer at higher temperatures, the separation could be performed on a conventional HPLC system obtaining peak widths at half height between 0.6 and 1.3 s.
Reversed-phase thin-layer chromatography of homologs of Antimycin-A and related derivatives
Abidi, Sharon L.
1989-01-01
Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.
Li, Austin C; Li, Yinghe; Guirguis, Micheal S; Caldwell, Robert G; Shou, Wilson Z
2007-01-04
A new analytical method is described here for the quantitation of anti-inflammatory drug cyclosporin A (CyA) in monkey and rat plasma. The method used tetrahydrofuran (THF)-water mobile phases to elute the analyte and internal standard, cyclosporin C (CyC). The gradient mobile phase program successfully eluted CyA into a sharp peak and therefore improved resolution between the analyte and possible interfering materials compared with previously reported analytical approaches, where CyA was eluted as a broad peak due to the rapid conversion between different conformers. The sharp peak resulted from this method facilitated the quantitative calculation as multiple smoothing and large number of bunching factors were not necessary. The chromatography in the new method was performed at 30 degrees C instead of 65-70 degrees C as reported previously. Other advantages of the method included simple and fast sample extraction-protein precipitation, direct injection of the extraction supernatant to column for analysis, and elimination of evaporation and reconstitution steps, which were needed in solid phase extraction or liquid-liquid extraction reported before. This method is amenable to high-throughput analysis with a total chromatographic run time of 3 min. This approach has been verified as sensitive, linear (0.977-4000 ng/mL), accurate and precise for the quantitation of CyA in monkey and rat plasma. However, compared with the usage of conventional mobile phases, the only drawback of this approach was the reduced detection response from the mass spectrometer that was possibly caused by poor desolvation in the ionization source. This is the first report to demonstrate the advantages of using THF-water mobile phases to elute CyA in liquid chromatography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Xian-Ming; Zhang, Yongfeng; Tonks, Michael R.
2015-02-01
Strong thermal gradients in low-thermal-conductivity ceramics may drive extended defects, such as grain boundaries and voids, to migrate in preferential directions. In this work, molecular dynamics simulations are conducted to study thermal gradient driven grain boundary migration and to verify a previously proposed thermal gradient driving force equation, using uranium dioxide as a model system. It is found that a thermal gradient drives grain boundaries to migrate up the gradient and the migration velocity increases under a constant gradient owing to the increase in mobility with temperature. Different grain boundaries migrate at very different rates due to their different intrinsicmore » mobilities. The extracted mobilities from the thermal gradient driven simulations are compared with those calculated from two other well-established methods and good agreement between the three different methods is found, demonstrating that the theoretical equation of the thermal gradient driving force is valid, although a correction of one input parameter should be made. The discrepancy in the grain boundary mobilities between modeling and experiments is also discussed.« less
Aral, Hayriye; Aral, Tarık; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep
2013-11-15
A novel amide-bonded silica stationary phase was prepared starting from N-Boc-phenylalanine, cyclohexylamine and spherical silica gel (4 µm, 60 Å). The amide ligand was synthesised with high yield. The resulting amide bonded stationary phase was characterised by SEM, IR and elemental analysis. The resulting selector bearing a polar amide group is used for the reversed-phase chromatography separation of different classes of thirteen phytohormones (plant hormones). The chromatographic behaviours of these analytes on the amide-silica stationary phase were compared with those of RP-C18 column under same conditions. The effects of different separation conditions, such as mobile phase, pH value, flow rate and temperature, on the separation and retention behaviours of the 13 phytohormones in this system were studied. The optimum separation was achieved using reversed-phase HPLC gradient elution with an aqueous mobile phase containing pH=6.85 potassium phosphate buffer (20 mM) and acetonitrile with a 22 °C column temperature. Under these experimental conditions, the 12 phytohormones could be separated and detected at 230 or 270 nm within 26 min. Copyright © 2013 Elsevier B.V. All rights reserved.
Lesellier, E; Mith, D; Dubrulle, I
2015-12-04
Analyses of complex samples of cosmetics, such as creams or lotions, are generally achieved by HPLC. These analyses are often multistep gradients, due to the presence of compounds with a large range of polarity. For instance, the bioactive compounds may be polar, while the matrix contains lipid components that are rather non-polar, thus cosmetic formulations are usually oil-water emulsions. Supercritical fluid chromatography (SFC) uses mobile phases composed of carbon dioxide and organic co-solvents, allowing for good solubility of both the active compounds and the matrix excipients. Moreover, the classical and well-known properties of these mobile phases yield fast analyses and ensure rapid method development. However, due to the large number of stationary phases available for SFC and to the varied additional parameters acting both on retention and separation factors (co-solvent nature and percentage, temperature, backpressure, flow rate, column dimensions and particle size), a simplified approach can be followed to ensure a fast method development. First, suited stationary phases should be carefully selected for an initial screening, and then the other operating parameters can be limited to the co-solvent nature and percentage, maintaining the oven temperature and back-pressure constant. To describe simple method development guidelines in SFC, three sample applications are discussed in this paper: UV-filters (sunscreens) in sunscreen cream, glyceryl caprylate in eye liner and caffeine in eye serum. Firstly, five stationary phases (ACQUITY UPC(2)) are screened with isocratic elution conditions (10% methanol in carbon dioxide). Complementary of the stationary phases is assessed based on our spider diagram classification which compares a large number of stationary phases based on five molecular interactions. Secondly, the one or two best stationary phases are retained for further optimization of mobile phase composition, with isocratic elution conditions or, when necessary, two-step gradient elution. The developed methods were then applied to real cosmetic samples to assess the method specificity, with regards to matrix interferences, and calibration curves were plotted to evaluate quantification. Besides, depending on the matrix and on the studied compounds, the importance of the detector type, UV or ELSD (evaporative light-scattering detection), and of the particle size of the stationary phase is discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
Wohlfarth, Ariane; Mahler, Hellmut; Auwärter, Volker
2011-10-15
Two isolation procedures for Δ9-tetrahydrocannabinolic acid A (THCA), the biogenetic precursor in the biosynthesis of the psychoactive Δ9-tetrahydrocannabinol (THC) in the cannabis plant, are presented. Two flash chromatography systems that can be used independently from each other were developed to separate THCA from other compounds of a crude cannabis extract. In both systems UV absorption at 209 and 270 nm was monitored. Purity was finally determined by HPLC-DAD, NMR and GC-MS analysis with a focus on the impurity THC. System 1 consisted of a normal phase silica column (120 g) as well as cyclohexane and acetone--both spiked with the modifier pyridine--as mobile phases. Gradient elution was performed over 15 min. After the chromatographic run the fractions containing THCA fractions were pooled, extracted with hydrochloric acid to eliminate pyridine and evaporated to dryness. Loading 1800 mg cannabis extract yielded 623 mg THCA with a purity of 99.8% and a THC concentration of 0.09%. System 2 was based on a reversed-phase C18 column (150 g) combined with 0.55% formic acid and methanol as mobile phases. A very flat gradient was set over 20 minutes. After pooling the THCA-containing fractions methanol was removed in a rotary evaporator. THCA was re-extracted from the remaining aqueous phase with methyl tert-butyl ether. The organic phase was finally evaporated under high vacuum conditions. Loading 300 mg cannabis extract yielded 51 mg THCA with a purity of 98.8% and a THC concentration of 0.67%. Copyright © 2011 Elsevier B.V. All rights reserved.
High-performance liquid-chromatographic separation of subcomponents of antimycin-A
Abidi, S.L.
1988-01-01
Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabhakaran Nair Syamala Amma, Aneesh; Hamid, Ahme
2018-02-28
Ion mobility (IM) spectrometry is becoming an important approach for analyzing molecular ions in the gas phase with applications that span a multitude of scientific areas. There are a variety of IM-based approaches that utilize either constant or oscillatory electric fields. Here, we explore the combination of constant and oscillatory fields applied in a single device to affect the separation and filtering of ions based on their mobilities. The mobility analyzer allows confining and manipulating ions utilizing a combination of radio frequency (RF), direct current (DC) fields, and traveling waves (TW) in a structures for lossless ion manipulations (SLIM) module.more » In this work, we have investigated theoretically and experimentally the concept for continuous filtering of ions based on their mobilities where ions are mobility separated and selected by a combination of TW and constant fields providing opposing forces on the ions. The SLIM module was composed of two surfaces with mirror-image arrays of electrodes and had two regions where the different TW and opposing DC fields could be applied. By appropriately choosing the DC gradient and TW parameters for the two sections, it is possible to transmit ions of a selected mobility while filtering out others. The filtering capabilities are determined by the applied DC gradient and the TW parameters, such as frequency, amplitude and the TW sequence (i.e., the duty cycle of the traveling wave). The effect of different parameters on the sensitivity and the IM resolution of the device have been investigated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabhakaran, Aneesh; Hamid, Ahmed M.; Garimella, Sandilya V. B.
Ion mobility (IM) spectrometry is becoming an important approach for analyzing molecular ions in the gas phase with applications that span a multitude of scientific areas. There are a variety of IM-based approaches that utilize either constant or oscillatory electric fields. Here, we explore the combination of constant and oscillatory fields applied in a single device to affect the separation and filtering of ions based on their mobilities. The mobility analyzer allows confining and manipulating ions utilizing a combination of radio frequency (RF), direct current (DC) fields, and traveling waves (TW) in a structures for lossless ion manipulations (SLIM) module.more » In this work, we have investigated theoretically and experimentally the concept for continuous filtering of ions based on their mobilities where ions are mobility separated and selected by a combination of TW and constant fields providing opposing forces on the ions. The SLIM module was composed of two surfaces with mirror-image arrays of electrodes and had two regions where the different TW and opposing DC fields could be applied. By appropriately choosing the DC gradient and TW parameters for the two sections, it is possible to transmit ions of a selected mobility while filtering out others. The filtering capabilities are determined by the applied DC gradient and the TW parameters, such as frequency, amplitude and the TW sequence (i.e., the duty cycle of the traveling wave). The effect of different parameters on the sensitivity and the IM resolution of the device have been investigated.« less
Fekete, Szabolcs; Veuthey, Jean-Luc; McCalley, David V; Guillarme, Davy
2012-12-28
A possible complication of ultra-high pressure liquid chromatography (UHPLC) is related to the effect of pressure and mobile phase velocity on the retention properties of the analytes. In the present work, numerous model compounds have been selected including small molecules, peptides, and proteins (such as monoclonal antibodies). Two instrumental setups were considered to attain elevated pressure drops, firstly the use of a post-column restrictor capillary at low mobile phase flow rate (pure effect of pressure) and secondly the increase of mobile phase flow rate without restrictor (i.e. a combined effect of pressure and frictional heating). In both conditions, the goal was to assess differences in retention behaviour, depending on the type or character of the analyte. An important conclusion is that the effect of pressure and mobile phase velocity on retention varied in proportion with the size of the molecule and in some cases showed very different behaviour. In isocratic mode, the pure effect of pressure (experiments with a post-column restrictor capillary) induces an increase in retention by 25-100% on small molecules (MW<300 g/mol), 150% for peptides (~1.3 kDa), 800% for insulin (~6 kDa) and up to >3000% for myoglobin (~17 kDa) for an increase in pressure from 100 bar up to 1100 bar. The important effect observed for the isocratic elution of proteins is probably related to conformational changes of the protein in addition to the effect of molecular size. Working in gradient elution mode, the pressure related effects on retention were found to be less pronounced but still present (an increase of apparent retention factor between 0.2 and 2.5 was observed). Copyright © 2012 Elsevier B.V. All rights reserved.
Van Os, E C; McKinney, J A; Zins, B J; Mays, D C; Schriver, Z H; Sandborn, W J; Lipsky, J J
1996-04-26
A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.
Johnson, Raymond H.; Tutu, Hlanganani; Brown, Adrian; Figueroa, Linda; Wolkersdorfer, Christian
2013-01-01
Geochemical changes that can occur down gradient from uranium in situ recovery (ISR) sites are important for various stakeholders to understand when evaluating potential effects on surrounding groundwater quality. If down gradient solid-phase material consists of sandstone with iron hydroxide coatings (no pyrite or organic carbon), sorption of uranium on iron hydroxides can control uranium mobility. Using one-dimensional reactive transport models with PHREEQC, two different geochemical databases, and various geochemical parameters, the uncertainties in uranium sorption on iron hydroxides are evaluated, because these oxidized zones create a greater risk for future uranium transport than fully reduced zones where uranium generally precipitates.
NASA Technical Reports Server (NTRS)
Plank, L. D.; Kunze, M. E.; Todd, P. W.
1985-01-01
Cultured mouse leukemia cells line L5178Y were subjected to upward electrophoresis in a density gradient and the slower migrating cell populations were enriched in G2 cells. It is indicated that this cell line does not change electrophoretic mobility through the cell cycle. The possibility that increased sedimentation downward on the part of the larger G2 cells caused this separation was explored. Two different cell populations were investigated. The log phase population was found to migrate upward faster than the G2 population, and a similar difference between their velocities and calculated on the basis of a 1 um diameter difference between the two cell populations. The G2 and G1 enriched populations were isolated by Ficoll density gradient sedimentation. The bottom fraction was enriched in G2 cells and the top fraction was enriched with G1 cells, especially when compared with starting materials. The electrophoretic mobilities of these two cell populations did not differ significantly from one another. Cell diameter dependent migration curves were calculated and were found to be different. Families of migration curves that differ when cell size is considered as a parameter are predicted.
Elkhoudary, Mahmoud M; Abdel Salam, Randa A; Hadad, Ghada M
2016-11-01
A new simple, sensitive, rapid and accurate gradient reversed-phase high-performance liquid chromatography with photodiode array detector (RP-HPLC-DAD) was developed and validated for simultaneous analysis of Metronidazole (MNZ), Spiramycin (SPY), Diloxanidefuroate (DIX) and Cliquinol (CLQ) using statistical experimental design. Initially, a resolution V fractional factorial design was used in order to screen five independent factors: the column temperature (°C), pH, phosphate buffer concentration (mM), flow rate (ml/min) and the initial fraction of mobile phase B (%). pH, flow rate and initial fraction of mobile phase B were identified as significant, using analysis of variance. The optimum conditions of separation determined with the aid of central composite design were: (1) initial mobile phase concentration: phosphate buffer/methanol (50/50, v/v), (2) phosphate buffer concentration (50 mM), (3) pH (4.72), (4) column temperature 30°C and (5) mobile phase flow rate (0.8 ml min -1 ). Excellent linearity was observed for all of the standard calibration curves, and the correlation coefficients were above 0.9999. Limits of detection for all of the analyzed compounds ranged between 0.02 and 0.11 μg ml -1 ; limits of quantitation ranged between 0.06 and 0.33 μg ml -1 The proposed method showed good prediction ability. The optimized method was validated according to ICH guidelines. Three commercially available tablets were analyzed showing good % recovery and %RSD. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Swobodnik, W; Klüppelberg, U; Wechsler, J G; Volz, M; Normandin, G; Ditschuneit, H
1985-05-03
This paper introduces a new method to detect the taurine and glycine conjugates of five different bile acids (cholic acid, deoxycholic acid, chenodeoxycholic acid, ursodeoxycholic acid and lithocholic acid) in human bile. Advantages of this method are sufficient separation of compounds within a short period of time and a high rate of reproducibility. Using a mobile phase gradient of acetonitrile and water, modified with tetrabutylammonium hydrogen sulphate (0.0075 mol/l), we were able to maximize the differentiation between ursodeoxycholic acid and lithocholic acid, which is of primary interest during conservative gallstone dissolution therapy. Use of this gradient reduced analysis time to less than 0.5 h. Recovery rates for this modified method ranged from 94% to 100%, and reproducibility was 98%, sufficient for routine clinical applications.
Quantitative aspects of vibratory mobilization and break-up of non-wetting fluids in porous media
NASA Astrophysics Data System (ADS)
Deng, Wen
Seismic stimulation is a promising technology aimed to mobilize the entrapped non-wetting fluids in the subsurface. The applications include enhanced oil recovery or, alternatively, facilitation of movement of immiscible/partly-miscible gases far into porous media, for example, for CO2 sequestration. This work is devoted to detailed quantitative studies of the two basic pore-scale mechanisms standing behind seismic stimulation: the mobilization of bubbles or drops entrapped in pore constrictions by capillary forces and the break-up of continuous long bubbles or drops. In typical oil-production operations, oil is produced by the natural reservoir-pressure drive during the primary stage and by artificial water flooding at the secondary stage. Capillary forces act to retain a substantial residual fraction of reservoir oil even after water flooding. The seismic stimulation is an unconventional technology that serves to overcome capillary barriers in individual pores and liberate the entrapped oil by adding an oscillatory inertial forcing to the external pressure gradient. According to our study, the effect of seismic stimulation on oil mobilization is highly dependent on the frequencies and amplitudes of the seismic waves. Generally, the lower the frequency and the larger the amplitude, more effective is the mobilization. To describe the mobilization process, we developed two theoretical hydrodynamics-based models and justified both using computational fluid dynamics (CFD). Our theoretical models have a significant advantage over CFD in that they reduce the computational time significantly, while providing correct practical guidance regarding the required field parameters of vibroseismic stimulation, such as the amplitude and frequency of the seismic field. The models also provide important insights into the basic mechanisms governing the vibration-driven two-phase flow in constricted capillaries. In a waterflooded reservoir, oil can be recovered most efficiently by forming continuous streams from isolated droplets. The longer the continuous oil phase under a certain pressure gradient, the more easily it overcomes its capillary barrier. However, surface tension between water and oil causes the typically non-wetting oil, constituting the core phase in the channels, to break up at the pore constriction into isolated beads, which inhibits further motion. The break-up thus counteracts the mobilization. We developed a theoretical model that provides an exact quantitative description of the dynamics of the oil-snap-off process. It also formulates a purely geometric criterion that controls, based on pore geometry only, whether the oil core phase stays continuous or disintegrates into droplets. Both the theoretical model and the break-criterion have been validated against CFD simulations. The work completed elucidates the basic physical mechanisms behind the enhanced oil recovery by seismic waves and vibrations. This creates a theoretical foundation for the further development of corresponding field technologies.
Blanco López, S L; Moal, J; San Juan Serrano, F
2000-09-01
Reversed-phase HPLC was applied to obtain a sensitive and efficient means for quantitating nucleotides in the mussel Mytilus galloprovincialis. We obtained a good separation of adenylic, guanylic, uridylic and cytidylic nucleotides. Adenine nucleotides play a critical role in the regulation and integration of cellular metabolism; particularly in the mantle tissue in the mussel, they are involved in the regulation of the enzyme glycogen phosphorylase, a key enzyme in the transfer of bioenergetic reserves (glycogen) to gametogenic development; it is of great importance to have a measure of the concentrations in vivo during the reproductive cycle of the organism. Different elution conditions were tested: isocratic versus step gradient elution, different mobile phase pH and the type and proportion of ion-pairing agent added to the mobile phase. The best method was selected and the separation and accurate determination of adenine, citidine, guanine and uridine nucleotides was accomplished within a 20-min run, with UV-Vis detection (254 nm).
Dai, J; Wang, H X; Chen, S W; Tang, J
2001-09-01
Hypersil BDS C18 and Zorbax SB C18, suitable to separate simultaneously seven kinds of catechins and caffeine, were screened out from seven brands of reversed-phase columns. Mobile phase was a solution of methanol-water-acetic acid (or trifluoro acetic acid). Seven kinds of catechins in tea samples from six places in China and three green tea polyphenol(GTP) samples from different producers were separated and determined in 30 min by isocratic and gradient elutions. The effects of mobile phase components and temperature of column on retention parameters of catechins and caffeine are reviewed. Chromatographic conditions and pretreatment methods of samples were optimized. Gallocatechin gallate(GCG) and (-)-catechin gallate(CG) were identified by electrospray ionization mass spectrometry(ESI-MS) and prepared by high performance liquid chromatography for quantitative analysis. The other catechins, (-)-epigallocatechin (EGC), (+)-catechin (D-C), (-)-epicatechin(EC), (-)-epigallocatechin gallate(EGCG), (-)-epicatechin gallate(ECG) were identified with standards.
USDA-ARS?s Scientific Manuscript database
An LC-MS/MS method was developed and validated to determine 7alpha-OH cholesterol in liver microsome. This method was convenient and fast with high specificity and sensitivity. Briefly, a gradient elution was performed on a Synergi polar-C18 column (50 x 4.6mm i.d., 3microm). The mobile phase (cons...
Kahsay, Getu; Song, Huiying; Eerdekens, Fran; Tie, Yaxin; Hendriks, Danny; Van Schepdael, Ann; Cabooter, Deirdre; Adams, Erwin
2015-01-01
Misoprostol is a synthetic prostaglandin E1 analogue which is mainly used for prevention and treatment of gastric ulcers, but also for abortion due to its labour inducing effect. Misoprostol exists as a mixture of diastereoisomers (1:1) and has several related impurities owing to its instability at higher temperatures and moisture. A simple and robust reversed phase liquid chromatographic (RPLC) method is described for the separation of the related substances and a normal phase (NP) LC method for the separation of misoprostol diastereoisomers. The RPLC method was performed using an Ascentis Express C18 (150 mm × 4.6 mm, 5 μm) column kept at 35 °C. The mobile phase was a gradient mixture of mobile phase A (ACN-H2O-MeOH, 28:69:3 v/v/v) and mobile phase B (ACN-H2O-MeOH, 47:50:3 v/v/v) eluted at a flow rate of 1.5 mL/min. UV detection was performed at 200 nm. The NPLC method was undertaken by using an XBridge bare silica (150 mm × 2.1 mm, 3.5 μm) column at 35 °C. The mobile phase contained 1-propanol-heptane-TFA (4:96:0.1%, v/v/v), pumped at a flow rate of 0.5 mL/min. UV detection was performed at 205 nm. This LC method can properly separate the two diastereoisomers (Rs > 2) within an analysis time of less than 20 min. Both methods were validated according to the ICH guidelines. Furthermore, these new LC methods have been successfully applied for purity control and diastereoisomers ratio determination of misoprostol bulk drug, tablets and dispersion. Copyright © 2015 Elsevier B.V. All rights reserved.
Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett
2014-08-01
Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Valko, K; Du, C M; Bevan, C D; Reynolds, D P; Abraham, M H
2000-08-01
A fast-gradient high-performance liquid chromatographic (HPLC) method has been suggested to characterize the interactions of drugs with an immobilized artificial membrane (IAM). With a set of standards, the gradient retention times can be converted to Chromatographic Hydrophobicity Index values referring to IAM chromatography (CHI(IAM)) that approximates an acetonitrile concentration with which the equal distribution of compound can be achieved between the mobile phase and IAM. The CHI(IAM) values are more suitable for interlaboratory comparison and for high throughput screening of new molecular entities than the log k(IAM) values (isocratic retention factor on IAM). The fast-gradient method has been validated against the isocratic log k(IAM) values using the linear free energy relationship solvation equations based on the data from 48 compounds. The compound set was selected to provide a wide range and the least cross-correlation between the molecular descriptors in the solvation equation: (2) where SP is a solute property (e.g., logarithm of partition coefficients, reversed-phase (RP)-HPLC retention parameters, such as log k, log k(w), etc.) and the explanatory variables are solute descriptors as follows: R(2) is an excess molar refraction that can be obtained from the measured refractive index of a compound, pi(2)(H) is the solute dipolarity/polarizability, summation operatoralpha(2)(H) and summation operatorbeta(2)(0) are the solute overall or effective hydrogen-bond acidity and basicity, respectively, and V(x) is the McGowan characteristic volume (in cm(3)/100 mol) that can be calculated for any solute simply from molecular structure using a table of atomic constants. It was found that the relative constants of the solvation equation were very similar for the CHI(IAM) and for the log k(IAM). The IAM lipophilicity scale was quite similar to the octanol/water lipophilicity scale for neutral compounds. The effect of charge on the interaction with IAM was studied by varying the mobile phase pH. Copyright 2000 Wiley-Liss, Inc.
Ishihara, Takashi; Kadoya, Toshihiko; Yamamoto, Shuichi
2007-08-24
We applied the model described in our previous paper to the rapid scale-up in the ion exchange chromatography of proteins, in which linear flow velocity, column length and gradient slope were changed. We carried out linear gradient elution experiments, and obtained data for the peak salt concentration and peak width. From these data, the plate height (HETP) was calculated as a function of the mobile phase velocity and iso-resolution curve (the separation time and elution volume relationship for the same resolution) was calculated. The scale-up chromatography conditions were determined by the iso-resolution curve. The scale-up of the linear gradient elution from 5 to 100mL and 2.5L column sizes was performed both by the separation of beta-lactoglobulin A and beta-lactoglobulin B with anion-exchange chromatography and by the purification of a recombinant protein with cation-exchange chromatography. Resolution, recovery and purity were examined in order to verify the proposed method.
Retention and effective diffusion of model metabolites on porous graphitic carbon.
Lunn, Daniel B; Yun, Young J; Jorgenson, James W
2017-12-29
The study of metabolites in biological samples is of high interest for a wide range of biological and pharmaceutical applications. Reversed phase liquid chromatography is a common technique used for the separation of metabolites, but it provides little retention for polar metabolites. An alternative to C18 bonded phases, porous graphitic carbon has the ability to provide significant retention for both non-polar and polar analytes. The goal of this work is to study the retention and effective diffusion properties of porous graphitic carbon, to see if it is suitable for the wide injection bands and long run times associated with long, packed capillary-scale separations. The retention of a set of standard metabolites was studied for both stationary phases over a wide range of mobile phase conditions. This data showed that porous graphitic carbon benefits from significantly increased retention (often >100 fold) under initial gradient conditions for these metabolites, suggesting much improved ability to focus a wide injection band at the column inlet. The effective diffusion properties of these columns were studied using peak-parking experiments with the standard metabolites under a wide range of retention conditions. Under the high retention conditions, which can be associated with retention after injection loading for gradient separations, D eff /D m ∼0.1 for both the C18-bonded and porous graphitic carbon columns. As C18 bonded particles are widely, and successfully utilized for long gradient separations without issue of increasing peak width from longitudinal diffusion, this suggests that porous graphitic carbon should be amenable for long runtime gradient separations as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Tian, Jingzhi; Rustum, Abu
2018-02-01
Imidacloprid is used as an active pharmaceutical ingredient (API) in veterinary drugs to control fleas and ticks for dogs and cats. Here we are reporting for the first time a validated stability-indicating reversed-phase UPLC-UV method for the assay of imidacloprid and estimation of its related compounds. The stability-indicating capability of this method has been demonstrated by a forced degradation study. All related compounds including processing impurities, imidacloprid API and degradates from stressed samples were well separated from each other. Structures of major degradates from forced degradation study were elucidated through UPLC-MS/MS and key degradation pathways were proposed from the proposed chemical structures of major degradates. The UPLC-UV method is carried out using an HSS T3 column (C18, 2.1 × 30 mm, 1.8 μm particle size) maintained at 30°C with mobile phase A (0.05% v/v of phosphoric acid in water) and mobile phase B (methanol/acetonitrile 75/25 v/v). Analytes are separated by a gradient elution and detected at 270 nm. The UPLC method is green and fast with only 6.5 min run time and about 3.5 ml mobile phase consumption for each sample analysis. The UPLC-UV method was validated according to ICH guidelines. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sendra, J M; Navarro, J L; Izquierdo, L
1988-09-01
A new analytical methodology for the determination of fully methoxylated flavones (FMFs) in citrus juices is described. Isolation of the FMFs is carried out by percolation of 30 mL of clarified citrus juice (to which tetramethyl-o-kaempferol is previously added as internal standard) through a C18 Sep-Pak cartridge, washing with 3 mL of water followed by 5 mL of water/acetonitrile (3:1), and selective elution of the retained FMFs with 5 mL of water/acetonitrile (9:11). Determination of the isolated FMFs is carried out by reversed-phase high-performance liquid chromatography (HPLC) and UV diode array detection (DAD). Signals at wavelengths 320, 335, and 345 nm (bandwidth 4 nm) are simultaneously acquired, stored, plotted, and integrated. The column used is a microbore (200 x 2.1-mm) Hypersil ODS 5 microns. Elution is in gradient mode, using a ternary mobile phase (water/acetonitrile/tetrahydrofuran). Column temperature is 40 degrees C. Recovery yields are nearly 100% for all the FMFs detected and identified: isosinensetin, hexamethyl-o-gossypetin, sinensetin, tetramethyl-o-isoscutellarein, hexamethyl-o-quercetagetin, nobiletin, tetramethyl-o-scutellarein, heptamethoxyflavone, and tangeretin. Chromatographic separation of the FMFs is extremely dependent upon the minor changes of the mobile phase composition and percentages, gradient rate, and temperature. The UV spectra (230 to 400 nm) of the FMFs obtained under chromatographic conditions are given. The FMFs relative response factors at 320, 335, and 345 nm and their concentrations in hand-squeezed and commercial concentrated orange and mandarin juices are tabulated. The FMF concentration differences found among samples are discussed.
Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2012-05-04
Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.
Chemical stability of oseltamivir in oral solutions.
Albert, K; Bockshorn, J
2007-09-01
The stability of oseltamivir in oral aqueous solutions containing the preservative sodium benzoate was studied by a stability indicating HPLC-method. The separation was achieved on a RP-18 ec column using a gradient of mobile phase A (aqueous solution of 50 mM ammonium acetate) and mobile phase B (60% (v/v) acetonitrile/40% (v/v) mobile phase A). The assay was subsequently validated according to the ICH guideline Q2(R1). The extemporaneously prepared "Oseltamivir Oral Solution 15 mg/ml for Adults or for Children" (NRF 31.2.) according to the German National Formulary ("Neues Rezeptur-Formularium") was stable for 84 days if stored under refrigeration. After storage at 25 degrees C the content of oseltamivir decreased to 98.4%. Considering the toxicological limit of 0.5% of the 5-acetylamino derivative (the so-called isomer I) the solution is stable for 46 days. Oseltamivir was less stable in a solution prepared with potable water instead of purified water. Due to an increasing pH the stability of this solution decreased to 14 days. Furthermore a white precipitate of mainly calcium phosphate was observed. The addition of 0.1% anhydrous citric acid avoided these problems and improved the stability of the solution prepared with potable water to 63 days. Sodium benzoate was stable in all oral solutions tested.
Chavez-Eng, C M; Lutz, R W; Li, H; Goykhman, D; Bateman, K P; Woolf, E
2016-02-01
An ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of (4S,5R)-5-[3,5-bis (trifluoromethyl)phenyl]-3-{[4'-fluoro-5'-isopropyl-2'-methoxy-4-(trifluoromethyl)biphenyl-2-yl] methyl}-4-methyl-1,3-oxazolidin-2-one (anacetrapib, I) and [(13)C5(15)N]-anacetrapib, II in human plasma has been developed to support a clinical study to determine the absolute bioavailability of I. The analytes and the stable-isotope labeled internal standard ([(13)C7(15)N(2)H7]-anacetrapib, III) were extracted from 100μL of human plasma by liquid-liquid extraction using 20/80 isopropyl alcohol/hexane (v/v). The chromatographic separation of the analytes was achieved using Waters BEH Shield RP 18 (50×2.1mm×1.7μm) column and mobile phase gradient of 0.1% formic acid in water (Solvent A) and 0.1% formic acid in acetonitrile (Solvent B) at 0.6mL/min flow rate. The MS/MS detection was performed on AB Sciex 5000 or AB 5500 in positive electrospray ionization mode, operated in selected reaction monitoring mode. The assay was validated in the concentration range 1-2000ng/mL for I; and a lower curve range, 0.025-50ng/mL for II. In addition to the absolute bioavailability determination, it was desired to better elucidate the pharmacokinetic behavior of several hydroxylated metabolites of I. Toward this end, two exploratory assays for the hydroxy metabolites of I were qualified in the concentration range 0.5-500ng/mL. All metabolites were separated on a Supelco Ascentis Express Phenyl-Hexyl (50×2.1mm, 2.7μm) column. Metabolite M4 was analyzed in the negative mode with a mobile phase consisting of a gradient mixture of water (A) and acetonitrile (B). The other three metabolites, M1-M3 were analyzed in the positive mode using a mobile phase gradient of water with 0.1% formic acid (A) and acetonitrile with 0.1% formic acid (B). The assays were utilized to support a clinical study in which a microdosing approach was used to determine the pharmacokinetics of anacetrapib and its metabolites. Copyright © 2016 Elsevier B.V. All rights reserved.
Yu, Chang Ho; Patel, Bhupendra; Palencia, Marilou; Fan, Zhihua Tina
2017-01-13
A selective, sensitive, and accurate analytical method for the measurement of perfluoroalkyl and polyfluoroalkyl substances (PFASs) in human serum, utilizing LC-MS/MS (liquid chromatography-tandem mass spectrometry), was developed and validated according to the Centers for Disease Control and Prevention (CDC) guidelines for biological sample analysis. Tests were conducted to determine the optimal analytical column, mobile phase composition and pH, gradient program, and cleaning procedure. The final analytical column selected for analysis was an extra densely bonded silica-packed reverse-phase column (Agilent XDB-C 8 , 3.0×100mm, 3.5μm). Mobile phase A was an aqueous buffer solution containing 10mM ammonium acetate (pH=4.3). Mobile phase B was a mixture of methanol and acetonitrile (1:1, v/v). The gradient program was programmed by initiating a fast elution (%B, from 40 to 65%) between 1.0 and 1.5min, followed by a slow elution (%B: 65-80%) in the period of 1.5-7.5min. The cleanup procedures were augmented by cleaning with (1) various solvents (isopropyl alcohol, methanol, acetonitrile, and reverse osmosis-purified water); (2) extensive washing steps for the autosampler and solid phase extraction (SPE) cartridge; and (3) a post-analysis cleaning step for the whole system. Under the above conditions, the resolution and sensitivity were significantly improved. Twelve target PFASs were baseline-separated (2.5-7.0min) within a 10-min of acquisition time. The limits of detection (LODs) were 0.01ng/mL or lower for all of the target compounds, making this method 5 times more sensitive than previously published methods. The newly developed method was validated in the linear range of 0.01-50ng/mL, and the accuracy (recovery between 80 and 120%) and precision (RSD<20%) were acceptable at three spiked levels (0.25, 2.5, and 25ng/mL). The method development and validation results demonstrated that this method was precise, accurate, and robust, with high-throughput (∼10min per sample); thus suitable for large-scale epidemiological studies. Published by Elsevier B.V.
Interfacial behavior of polymer electrolytes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerr, John; Kerr, John B.; Han, Yong Bong
2003-06-03
Evidence is presented concerning the effect of surfaces on the segmental motion of PEO-based polymer electrolytes in lithium batteries. For dry systems with no moisture the effect of surfaces of nano-particle fillers is to inhibit the segmental motion and to reduce the lithium ion transport. These effects also occur at the surfaces in composite electrodes that contain considerable quantities of carbon black nano-particles for electronic connection. The problem of reduced polymer mobility is compounded by the generation of salt concentration gradients within the composite electrode. Highly concentrated polymer electrolytes have reduced transport properties due to the increased ionic cross-linking. Combinedmore » with the interfacial interactions this leads to the generation of low mobility electrolyte layers within the electrode and to loss of capacity and power capability. It is shown that even with planar lithium metal electrodes the concentration gradients can significantly impact the interfacial impedance. The interfacial impedance of lithium/PEO-LiTFSI cells varies depending upon the time elapsed since current was turned off after polarization. The behavior is consistent with relaxation of the salt concentration gradients and indicates that a portion of the interfacial impedance usually attributed to the SEI layer is due to concentrated salt solutions next to the electrode surfaces that are very resistive. These resistive layers may undergo actual phase changes in a non-uniform manner and the possible role of the reduced mobility polymer layers in dendrite initiation and growth is also explored. It is concluded that PEO and ethylene oxide-based polymers are less than ideal with respect to this interfacial behavior.« less
Liu, Junguo; Song, Jiuxue; Huang, Karen; Michel, Deborah; Fang, Jim
2018-05-01
A high-performance liquid chromatography tandem-mass spectrometry (HPLC-MS/MS) method has been developed to analyze anthocyanins in urine and plasma to further understand their absorption, distribution, metabolism and excretion. The method employed a Synergi RP-Max column (250 × 4.6 mm, 4 μm) and an API 4000 mass spectrometer. A gradient elution system consisted of mobile phase A (water-1% formic acid) and mobile phase B (acetonitrile) with a flow rate of 0.60 mL/min. The gradient was initiated at 5% B, increased to 21% B at 20 min, and then increased to 40% B at 35 min. The analysis of anthocyanins presents a challenge because of the poor stability of anthocyanins during sample preparation, especially during solvent evaporation. In this method, the degradation of anthocyanins was minimized using protein precipitation and dilute-and-shoot and sample preparation methods for plasma and urine, respectively. No interferences were observed from endogenous compounds. The method has been used to analyze anthocyanin concentrations in urine and plasma samples from volunteers administered saskatoon berries. Cyanidin-3-galactoside, cyanidin-3-glucoside, cyanidin-3-arabinoside, cyanidin-3-xyloside and quercetin-3-galactoside, the five major flavonoid components in saskatoon berries, were identified in plasma and urine samples. Copyright © 2017 John Wiley & Sons, Ltd.
Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M
2010-02-05
Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.
Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Patrick Allen
2005-12-17
Quantification in liquid chromatography (LC) is becoming very important as more researchers are using LC, not as an analytical tool itself, but as a sample introduction system for other analytical instruments. The ability of LC instrumentation to quickly separate a wide variety of compounds makes it ideal for analysis of complex mixtures. For elemental speciation, LC is joined with inductively coupled plasma mass spectrometry (ICP-MS) to separate and detect metal-containing, organic compounds in complex mixtures, such as biological samples. Often, the solvent gradients required to perform complex separations will cause matrix effects within the plasma. This limits the sensitivity ofmore » the ICP-MS and the quantification methods available for use in such analyses. Traditionally, isotope dilution has been the method of choice for LC-ICP-MS quantification. The use of naturally abundant isotopes of a single element in quantification corrects for most of the effects that LC solvent gradients produce within the plasma. However, not all elements of interest in speciation studies have multiple naturally occurring isotopes; and polyatomic interferences for a given isotope can develop within the plasma, depending on the solvent matrix. This is the case for reverse phase LC separations, where increasing amounts of organic solvent are required. For such separations, an alternative to isotope dilution for quantification would be is needed. To this end, a new method was developed using the Apex-Q desolvation system (ESI, Omaha, NE) to couple LC instrumentation with an ICP-MS device. The desolvation power of the system allowed greater concentrations of methanol to be introduced to the plasma prior to destabilization than with direct methanol injection into the plasma. Studies were performed, using simulated and actual linear methanol gradients, to find analyte-internal standard (AIS) pairs whose ratio remains consistent (deviations {+-} 10%) over methanol concentration ranges of 5%-35% (simulated) and 8%-32% (actual). Quadrupole (low resolution) and sector field (high resolution) ICP-MS instrumentation were utilized in these studies. Once an AIS pair is determined, quantification studies can be performed. First, an analysis is performed by adding both elements of the AIS pair post-column while performing the gradient elution without sample injection. A comparison of the ratio of the measured intensities to the atomic ratio of the two standards is used to determine a correction factor that can be used to account for the matrix effects caused by the mobile phase. Then, organic and/or biological molecules containing one of the two elements in the AIS pair are injected into the LC column. A gradient method is used to vary the methanol-water mixture in the mobile phase and to separate out the compounds in a given sample. A standard solution of the second ion in the AIS pair is added continuously post-column. By comparing the ratio of the measured intensities to the atomic ratio of the eluting compound and internal standard, the concentration of the injected compound can be determined.« less
Byrne, Jonathan; Velasco-Torrijos, Trinidad; Reinhardt, Robert
2014-08-05
A novel stability-indicating reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous assay of betamethasone-17-valerate, fusidic acid and potassium sorbate as well as methyl- and propylparaben in a topical cream preparation has been developed. A 100mm×3.0mm ID. Ascentis Express C18 column maintained at 30°C and UV detection at 240nm were used. A gradient programme was employed at a flow-rate of 0.75ml/min. Mobile phase A comprised of an 83:17 (v/v) mixture of acetonitrile and methanol and mobile phase B of a 10g/l solution of 85% phosphoric acid in purified water. The method has been validated according to current International Conference on Harmonisation (ICH) guidelines and applied during formulation development and stability studies. The procedure has been shown to be stability-indicating for the topical cream. Copyright © 2014 Elsevier B.V. All rights reserved.
Preparative electrophoresis of cultured human cells: Effect of cell cycle phase
NASA Technical Reports Server (NTRS)
Kunze, M. E.; Todd, P. W.; Goolsby, C. L.; Walker, J. T.
1985-01-01
Human epithelioid T-1E cells were cultured in suspension and subjected to density gradient electrophoresis upward in a vertical column. It is indicated that the most rapidly migrating cells were at the beginning of the cell cycle and the most slowly migrating cells were at the end of the cell cycle. The fastest migrating cells divided 24 hr later than the slowest migrating cells. Colonies developing from slowly migrating cells had twice as many cells during exponential growth as did the most rapidly migrating cells, and the numbers of cells per colony at any time was inversely related to the electrophoretic migration rate. The DNA measurements by fluorescence flow cytometry indicates that the slowest migrating cell populations are enriched in cells that have twice as much DNA as the fastest migrating cells. It is concluded that electrophoretic mobility of these cultured human cells declines steadily through the cell cycle and that the mobility is lowest at the end of G sub 2 phase and highest at the beginning of G sub 1 phase.
Hutchinson, Joseph P; Li, Jianfeng; Farrell, William; Groeber, Elizabeth; Szucs, Roman; Dicinoski, Greg; Haddad, Paul R
2011-03-25
The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 μL. Copyright © 2011 Elsevier B.V. All rights reserved.
Ion-exchange chromatography for the characterization of biopharmaceuticals.
Fekete, Szabolcs; Beck, Alain; Veuthey, Jean-Luc; Guillarme, Davy
2015-09-10
Ion-exchange chromatography (IEX) is a historical technique widely used for the detailed characterization of therapeutic proteins and can be considered as a reference and powerful technique for the qualitative and quantitative evaluation of charge heterogeneity. The goal of this review is to provide an overview of theoretical and practical aspects of modern IEX applied for the characterization of therapeutic proteins including monoclonal antibodies (Mabs) and antibody drug conjugates (ADCs). The section on method development describes how to select a suitable stationary phase chemistry and dimensions, the mobile phase conditions (pH, nature and concentration of salt), as well as the temperature and flow rate, considering proteins isoelectric point (pI). In addition, both salt-gradient and pH-gradient approaches were critically reviewed and benefits as well as limitations of these two strategies were provided. Finally, several applications, mostly from pharmaceutical industries, illustrate the potential of IEX for the characterization of charge variants of various types of biopharmaceutical products. Copyright © 2015 Elsevier B.V. All rights reserved.
Andrade-Eiroa, Auréa; Diévart, Pascal; Dagaut, Philippe
2010-04-15
A new procedure for optimizing PAHs separation in very complex mixtures by reverse phase high performance (RPLC) is proposed. It is based on changing gradually the experimental conditions all along the chromatographic procedure as a function of the physical properties of the compounds eluted. The temperature and speed flow gradients allowed obtaining the optimum resolution in large chromatographic determinations where PAHs with very different medium polarizability have to be separated. Whereas optimization procedures of RPLC methodologies had always been accomplished regardless of the physico-chemical properties of the target analytes, we found that resolution is highly dependent on the physico-chemical properties of the target analytes. Based on resolution criterion, optimization process for a 16 EPA PAHs mixture was performed on three sets of difficult-to-separate PAHs pairs: acenaphthene-fluorene (for the optimization procedure in the first part of the chromatogram where light PAHs elute), benzo[g,h,i]perylene-dibenzo[a,h]anthracene and benzo[g,h,i]perylene-indeno[1,2,3-cd]pyrene (for the optimization procedure of the second part of the chromatogram where the heavier PAHs elute). Two-level full factorial designs were applied to detect interactions among variables to be optimized: speed flow, temperature of column oven and mobile-phase gradient in the two parts of the studied chromatogram. Experimental data were fitted by multivariate nonlinear regression models and optimum values of speed flow and temperature were obtained through mathematical analysis of the constructed models. An HPLC system equipped with a reversed phase 5 microm C18, 250 mm x 4.6mm column (with acetonitrile/water mobile phase), a column oven, a binary pump, a photodiode array detector (PDA), and a fluorimetric detector were used in this work. Optimum resolution was achieved operating at 1.0 mL/min in the first part of the chromatogram (until 45 min) and 0.5 mL/min in the second one (from 45 min to the end) and by applying programmed temperature gradient (15 degrees C until 30 min and progressively increasing temperature until reaching 40 degrees C at 45 min). (c) 2009 Elsevier B.V. All rights reserved.
Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C
2017-11-10
An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real injection profiles obtained from 2D-LC interface valves are used to simulate the introduction of samples into the 2 D column. These profiles are highly asymmetric - simulation using simple rectangular pulses leads to peak widths that are far too narrow under many conditions. We believe the simulation approach developed here will be useful for addressing practical questions in the development of 2D-LC methods. Copyright © 2017 Elsevier B.V. All rights reserved.
An Experimental Design Approach for Impurity Profiling of Valacyclovir-Related Products by RP-HPLC
Katakam, Prakash; Dey, Baishakhi; Hwisa, Nagiat T; Assaleh, Fathi H; Chandu, Babu R; Singla, Rajeev K; Mitra, Analava
2014-01-01
Abstract Impurity profiling has become an important phase of pharmaceutical research where both spectroscopic and chromatographic methods find applications. The analytical methodology needs to be very sensitive, specific, and precise which will separate and determine the impurity of interest at the 0.1% level. Current research reports a validated RP-HPLC method to detect and separate valacyclovir-related impurities (Imp-E and Imp-G) using the Box-Behnken design approach of response surface methodology. A gradient mobile phase (buffer: acetonitrile as mobile phase A and acetonitrile: methanol as mobile phase B) was used. Linearity was found in the concentration range of 50–150 μg/mL. The mean recovery of impurities was 99.9% and 103.2%, respectively. The %RSD for the peak areas of Imp-E and Imp-G were 0.9 and 0.1, respectively. No blank interferences at the retention times of the impurities suggest the specificity of the method. The LOD values were 0.0024 μg/mL for Imp-E and 0.04 μg/mL for Imp-G and the LOQ values were obtained as 0.0082 μg/mL and 0.136 μg/mL, respectively, for the impurities. The S/N ratios in both cases were within the specification limits. Proper peak shapes and satisfactory resolution with good retention times suggested the suitability of the method for impurity profiling of valacyclovir-related drug substances. PMID:25853072
Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin
2013-03-05
A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Synovec, Robert E.; Renn, Curtiss N.
1991-07-01
The refractive index gradient (RIG) of hydrodynamically controlled profiles can be universally, yet sensitively, measured by carefully probing the radial RIG passing through a z-configuration flow cell. Fiber optic technology is applied in order to provide a narrow, collimated probe beam (100 micrometers diameter) that is deflected by a RIG and measured by a position sensitive detector. The fiber optic construction allows one to probe very small volumes (1 (mu) L to 3 (mu) L) amenable to microbore liquid chromatography ((mu) LC). The combination of (mu) LC and RIG detection is very useful for the analysis of trace quantities (ng injected amounts) of chemical species that are generally difficult to measure, i.e., species that are not amenable to absorbance detection or related techniques. Furthermore, the RIG detector is compatible with conventional mobile phase gradient and thermal gradient (mu) LC, unlike traditional RI detectors. A description of the RIG detector coupled with (mu) LC for the analysis of complex polymer samples is reported. Also, exploration into using the RIG detector for supercritical fluid chromatography is addressed.
Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich
2011-12-01
Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.
Al-Degs, Yahya; Andri, Bertyl; Thiébaut, Didier; Vial, Jérôme
2017-01-01
Retention mechanisms involved in supercritical fluid chromatography (SFC) are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase), a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC) was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition). Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition) data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns' function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components. PMID:28695040
Rabinovich-Guilatt, Laura; Dubernet, Catherine; Gaudin, Karen; Lambert, Gregory; Couvreur, Patrick; Chaminade, Pierre
2005-09-01
The aim of this work was to develop a simple high-performance liquid chromatography (HPLC) technique with evaporative light scattering detection (ELSD) for the separation and quantification of the major phospholipid (PL) and lysophospholipid (LPL) classes contained in a pharmaceutical phospholipid-based emulsion. In the established method, phosphatidylcholine (PC), phosphatidylethanolamine (PE), sphingomyeline (SM), lysophosphatidylcholine (LPC) and lysophosphatidylethanolamine (LPE) were separated with a PVA-Sil stationary phase and a binary gradient from pure chloroform to methanol:water (94:6 v/v) at 3.4%/min. The ELSD detection was enhanced using 0.1% triethylamine and formic acid in each gradient mobile phases. Factors such as stationary phase and ELSD drift tube temperature were optimized, concluding in optimal temperatures of 25 degrees C for separation and 50 degrees C for evaporation. This HPLC-ELSD method was then applied to a PL-emulsion exposed to autoclaving and accelerated thermal conditions at 50 degrees C. Hydrolysis of PC and PE followed first-order kinetics, representing only 45% of the total lipid mass after 3 months. The chemical stability was correlated to commonly measured formulation physical and physico-chemical parameters such as droplet size, emulsion pH and zeta-potential.
Hung, Chuan-Hsi; Zukowski, Janusz; Jensen, David S; Miles, Andrew J; Sulak, Clayton; Dadson, Andrew E; Linford, Matthew R
2015-09-01
Three mixed-mode high-performance liquid chromatography columns packed with superficially porous carbon/nanodiamond/amine-polymer particles were used to separate mixtures of cannabinoids. Columns evaluated included: (i) reversed phase (C18 ), weak anion exchange, 4.6 × 33 mm, 3.6 μm, and 4.6 × 100 mm, 3.6 μm, (ii) reversed phase, strong anion exchange (quaternary amine), 4.6×33 mm, 3.6 μm, and (iii) hydrophilic interaction liquid chromatography, 4.6 × 150 mm, 3.6 μm. Different selectivities were achieved under various mobile phase and stationary phase conditions. Efficiencies and peak capacities were as high as 54 000 N/m and 56, respectively. The reversed phase mixed-mode column (C18 ) retained tetrahydrocannabinolic acid strongly under acidic conditions and weakly under basic conditions. Tetrahydrocannabinolic acid was retained strongly on the reversed phase, strong anion exchange mixed-mode column under basic polar organic mobile phase conditions. The hydrophilic interaction liquid chromatography column retained polar cannabinoids better than the (more) neutral ones under basic conditions. A longer reversed phase (C18 ) mixed-mode column (4.6 × 100 mm) showed better resolution for analytes (and a contaminant) than a shorter column. Fast separations were achieved in less than 5 min and sometimes 2 min. A real world sample (bubble hash extract) was also analyzed by gradient elution. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effect of temperature gradient on liquid-liquid phase separation in a polyolefin blend.
Jiang, Hua; Dou, Nannan; Fan, Guoqiang; Yang, Zhaohui; Zhang, Xiaohua
2013-09-28
We have investigated experimentally the structure formation processes during phase separation via spinodal decomposition above and below the spinodal line in a binary polymer blend system exposed to in-plane stationary thermal gradients using phase contrast optical microscopy and temperature gradient hot stage. Below the spinodal line there is a coupling of concentration fluctuations and thermal gradient imposed by the temperature gradient hot stage. Also under the thermal gradient annealing phase-separated domains grow faster compared with the system under homogeneous temperature annealing on a zero-gradient or a conventional hot stage. We suggest that the in-plane thermal gradient accelerates phase separation through the enhancement in concentration fluctuations in the early and intermediate stages of spinodal decomposition. In a thermal gradient field, the strength of concentration fluctuation close to the critical point (above the spinodal line) is strong enough to induce phase separation even in one-phase regime of the phase diagram. In the presence of a temperature gradient the equilibrium phase diagrams are no longer valid, and the systems with an upper critical solution temperature can be quenched into phase separation by applying the stationary temperature gradient. The in-plane temperature gradient drives enhanced concentration fluctuations in a binary polymer blend system above and below the spinodal line.
Analysis of iodinated quorum sensing peptides by LC-UV/ESI ion trap mass spectrometry.
Janssens, Yorick; Verbeke, Frederick; Debunne, Nathan; Wynendaele, Evelien; Peremans, Kathelijne; De Spiegeleer, Bart
2018-02-01
Five different quorum sensing peptides (QSP) were iodinated using different iodination techniques. These iodinated peptides were analyzed using a C 18 reversed phase HPLC system, applying a linear gradient of water and acetonitrile containing 0.1% (m/v) formic acid as mobile phase. Electrospray ionization (ESI) ion trap mass spectrometry was used for the identification of the modified peptides, while semi-quantification was performed using total ion current (TIC) spectra. Non-iodinated peptides and mono- and di-iodinated peptides (NIP, MIP and DIP respectively) were well separated and eluted in that order. Depending on the used iodination method, iodination yields varied from low (2%) to high (57%).
Nanoscale Origins of Ferroelastic Domain Wall Mobility in Ferroelectric Multilayers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Hsin-Hui; Hong, Zijian; Xin, Huolin L.
Here we investigate the nanoscale origins of ferroelastic domain wall motion in ferroelectric multilayer thin films that lead to giant electromechanical responses. We present direct evidence for complex underpinning factors that result in ferroelastic domain wall mobility using a combination of atomic-level aberration corrected scanning transmission electron microscopy and phase-field simulations in model epitaxial (001) tetragonal (T) PbZr xTi 1-xO 3 (PZT)/rhombohedral (R) PbZr xTi 1-xO 3 (PZT) bilayer heterostructures. The local electric dipole distribution is imaged on an atomic scale for a ferroelastic domain wall that nucleates in the R-layer and cuts through the composition breaking the T/R interface.more » Our studies reveal a highly complex polarization rotation domain structure that is nearly on the knife-edge at the vicinity of this wall. Induced phases, namely tetragonal-like and rhombohedral-like monoclinic were observed close to the interface, and exotic domain arrangements, such as a half-four-fold closure structure, are observed. Phase field simulations show this is due to the minimization of the excessive elastic and electrostatic energies driven by the enormous strain gradient present at the location of the ferroelastic domain walls. Thus, in response to an applied stimulus, such as an electric field, any polarization reorientation must minimize the elastic and electrostatic discontinuities due to this strain gradient, which would induce a dramatic rearrangement of the domain structure. This insight into the origins of ferroelastic domain wall motion will allow researchers to better “craft” such multilayered ferroelectric systems with precisely tailored domain wall functionality and enhanced sensitivity, which can be exploited for the next generation of integrated piezoelectric technologies.« less
Nanoscale Origins of Ferroelastic Domain Wall Mobility in Ferroelectric Multilayers
Huang, Hsin-Hui; Hong, Zijian; Xin, Huolin L.; ...
2016-10-31
Here we investigate the nanoscale origins of ferroelastic domain wall motion in ferroelectric multilayer thin films that lead to giant electromechanical responses. We present direct evidence for complex underpinning factors that result in ferroelastic domain wall mobility using a combination of atomic-level aberration corrected scanning transmission electron microscopy and phase-field simulations in model epitaxial (001) tetragonal (T) PbZr xTi 1-xO 3 (PZT)/rhombohedral (R) PbZr xTi 1-xO 3 (PZT) bilayer heterostructures. The local electric dipole distribution is imaged on an atomic scale for a ferroelastic domain wall that nucleates in the R-layer and cuts through the composition breaking the T/R interface.more » Our studies reveal a highly complex polarization rotation domain structure that is nearly on the knife-edge at the vicinity of this wall. Induced phases, namely tetragonal-like and rhombohedral-like monoclinic were observed close to the interface, and exotic domain arrangements, such as a half-four-fold closure structure, are observed. Phase field simulations show this is due to the minimization of the excessive elastic and electrostatic energies driven by the enormous strain gradient present at the location of the ferroelastic domain walls. Thus, in response to an applied stimulus, such as an electric field, any polarization reorientation must minimize the elastic and electrostatic discontinuities due to this strain gradient, which would induce a dramatic rearrangement of the domain structure. This insight into the origins of ferroelastic domain wall motion will allow researchers to better “craft” such multilayered ferroelectric systems with precisely tailored domain wall functionality and enhanced sensitivity, which can be exploited for the next generation of integrated piezoelectric technologies.« less
NASA Technical Reports Server (NTRS)
Lehoczky, S. L.; Szofran, F. R.; Martin, B. G.
1980-01-01
Mercury cadmium telluride crystals were prepared by the Bridgman method with a wide range of crystal growth rates and temperature gradients adequate to prevent constitutional supercooling under diffusion-limited, steady state, growth conditions. The longitudinal compositional gradients for different growth conditions and alloy compositions were calculated and compared with experimental data to develop a quantitative model of the crystal growth kinetics for the Hg(i-x)CdxTe alloys, and measurements were performed to ascertain the effect of growth conditions on radial compositional gradients. The pseudobinary HgTe-CdTe constitutional phase diagram was determined by precision differential thermal analysis measurements and used to calculate the segregation coefficient of Cd as a function of x and interface temperature. Computer algorithms specific to Hg(1-x)CdxTe were developed for calculations of the charge carrier concentrations, charge carrier mobilities, Hall coefficient, optical absorptance, and Fermi energy as functions of x, temperature, ionized donor and acceptor concentrations, and neutral defect concentrations.
Stankovicha, Joseph J; Gritti, Fabrice; Beaver, Lois Ann; Stevensona, Paul G; Guiochon, Georges
2013-11-29
Five methods were used to implement fast gradient separations: constant flow rate, constant column-wall temperature, constant inlet pressure at moderate and high pressures (controlled by a pressure controller),and programmed flow constant pressure. For programmed flow constant pressure, the flow rates and gradient compositions are controlled using input into the method instead of the pressure controller. Minor fluctuations in the inlet pressure do not affect the mobile phase flow rate in programmed flow. There producibilities of the retention times, the response factors, and the eluted band width of six successive separations of the same sample (9 components) were measured with different equilibration times between 0 and 15 min. The influence of the length of the equilibration time on these reproducibilities is discussed. The results show that the average column temperature may increase from one separation to the next and that this contributes to fluctuation of the results.
Kim, Won Il; Zhao, Bing Tian; Zhang, Hai Yan; Lee, Je Hyun; Son, Jong Keun; Woo, Mi Hee
2014-01-01
Two rapid and simple HPLC methods with UV detector to determine three main compounds (magnoflorine, spinosin and 6'''-feruloyl spinosin) and evaporative light scattering detector (ELSD) to determine jujuboside A were developed for the chemical analyses of Zizyphi Semen. Magnoflorine, spinosin, and 6'''-feruloyl spinosin were separated with an YMC J'sphere ODS-H80 column (250 mm × 4.6 mm, 4 μm) by the gradient elution followed by the isocratic elution using methanol with 0.1 % formic acid and water with 0.1 % formic acid as the mobile phase. The flow rate was 1.0 mL/min. Jujuboside A was separated by HPLC-ELSD with YoungJinBioChrom Aegispak C18-L column (250 mm × 4.6 mm, 5 μm) column in a gradient elution using methanol with 0.1 % formic acid (A) and water with 0.1 % formic acid as the mobile phase. These two methods were fully validated with respect to linearity, precision, accuracy, stability, and robustness. These HPLC methods were applied successfully to quantify four compounds in a Zizyphi Semen extract. The HPLC analytical methods were validated for pattern recognition analysis by repeated analysis of 91 seed samples corresponding to 48 Zizyphus jujuba var. spinosa (J01-J48) and 43 Zizyphus mauritiana (M01-M43). The results indicate that these methods are suitable for a quality evaluation of Zizyphi Semen.
Kluters, Simon; Wittkopp, Felix; Jöhnck, Matthias; Frech, Christian
2016-02-01
The mobile phase pH is a key parameter of every ion exchange chromatography process. However, mechanistic insights into the pH influence on the ion exchange chromatography equilibrium are rare. This work describes a mechanistic model capturing salt and pH influence in ion exchange chromatography. The pH dependence of the characteristic protein charge and the equilibrium constant is introduced to the steric mass action model based on a protein net charge model considering the number of amino acids interacting with the stationary phase. This allows the description of the adsorption equilibrium of the chromatographed proteins as a function of pH. The model parameters were determined for a monoclonal antibody monomer, dimer, and a higher aggregated species based on a manageable set of pH gradient experiments. Without further modification of the model parameters the transfer to salt gradient elution at fixed pH is demonstrated. A lumped rate model was used to predict the separation of the monoclonal antibody monomer/aggregate mixture in pH gradient elution and for a pH step elution procedure-also at increased protein loadings up to 48 g/L packed resin. The presented model combines both salt and pH influence and may be useful for the development and deeper understanding of an ion exchange chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Šatínský, Dalibor; Naibrtová, Linda; Fernández-Ramos, Carolina; Solich, Petr
2015-09-01
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100×4.6 mm), particle size 2.7 µm with mobile phase acetonitrile:water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45°C. Large volume sample injection (1500 µL) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5×4.6 mm); fused-core particle size 2.7 µm allowed effective sample preconcentration and efficient ballast sample matrix removal. The washing mobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone from the extraction to the separation column was set at 3rd min. Elution of preconcentrated insecticides from the extraction precolumn and separation on the analytical column was performed in gradient mode. Linear gradient elution started from 40% of acetonitrile at time of valve switch from SPE column (3rd min) to 95% of acetonitrile at 7th min. Synthetic dye sudan I was chosen as an internal standard. UV detection at wavelength 225 nm was used and the method reached the limits of detection (LOD) at ng mL(-1) levels for both insecticides. The method showing on-line sample pretreatment and preconcentration with highly sensitive determination of insecticides was applied for monitoring of fenoxycarb and both permethrin isomers in different surface water samples in Czech Republic. The time of whole analysis including on-line extraction, interferences removal, chromatography separation and system equilibration was less than 8 min. Copyright © 2015 Elsevier B.V. All rights reserved.
Debrus, Benjamin; Guillarme, Davy; Rudaz, Serge
2013-10-01
A complete strategy dedicated to quality-by-design (QbD) compliant method development using design of experiments (DOE), multiple linear regressions responses modelling and Monte Carlo simulations for error propagation was evaluated for liquid chromatography (LC). The proposed approach includes four main steps: (i) the initial screening of column chemistry, mobile phase pH and organic modifier, (ii) the selectivity optimization through changes in gradient time and mobile phase temperature, (iii) the adaptation of column geometry to reach sufficient resolution, and (iv) the robust resolution optimization and identification of the method design space. This procedure was employed to obtain a complex chromatographic separation of 15 antipsychotic basic drugs, widely prescribed. To fully automate and expedite the QbD method development procedure, short columns packed with sub-2 μm particles were employed, together with a UHPLC system possessing columns and solvents selection valves. Through this example, the possibilities of the proposed QbD method development workflow were exposed and the different steps of the automated strategy were critically discussed. A baseline separation of the mixture of antipsychotic drugs was achieved with an analysis time of less than 15 min and the robustness of the method was demonstrated simultaneously with the method development phase. Copyright © 2013 Elsevier B.V. All rights reserved.
Penchala, Sujan Dilly; Tjia, John; El Sherif, Omar; Back, David J; Khoo, Saye H; Else, Laura J
2013-08-01
A sensitive high-performance reverse phase liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of telaprevir and its inactive R-diastereomer (VRT-127394) in human plasma. The analytes and the internal standard (telaprevir-d11) were extracted from plasma by liquid-liquid extraction using tert-Butyl methyl ether (TBME). Chromatographic separation was achieved on a reversed-phase Accucore C18 column with a gradient programme consisting of water:ammonia (25%), 100:0.01 (v/v) (mobile phase A) and ACN:MeOH:ammonia (25%), 15:85:0.01 (v/v/v) (mobile phase B). The MS acquisition was performed with selective reaction monitoring mode using the respective [M+H](+) ions, m/z 680.59→322.42 for telaprevir and VRT-127394, and 691.15→110.13 for telaprevir-d11. The assay exhibited a linear dynamic range of 5-5000ng/mL for telaprevir and VRT-127394. Acceptable precision (%RSD<6.5%) and accuracy (94-108%) were obtained for concentrations over the range of the standard curve. A procedure was established to stabilise the plasma to prevent ex vivo interconversion of the isomers. Copyright © 2013 Elsevier B.V. All rights reserved.
Cífková, Eva; Hájek, Roman; Lísa, Miroslav; HolĿapek, Michal
2016-03-25
The goal of this work is a systematic optimization of hydrophilic interaction liquid chromatography (HILIC) separation of acidic lipid classes (namely phosphatidic acids-PA, lysophosphatidic acids-LPA, phosphatidylserines-PS and lysophosphatidylserines-LPS) and other lipid classes under mass spectrometry (MS) compatible conditions. The main parameters included in this optimization are the type of stationary phases used in HILIC, pH of the mobile phase, the type and concentration of mobile phase additives. Nine HILIC columns with different chemistries (unmodified silica, modified silica using diol, 2-picolylamine, diethylamine and 1-aminoanthracene and hydride silica) are compared with the emphasis on peak shapes of acidic lipid classes. The optimization of pH is correlated with the theoretical calculation of acidobasic equilibria of studied lipid classes. The final method using the hydride column, pH 4 adjusted by formic acid and the gradient of acetonitrile and 40 mmol/L of aqueous ammonium formate provides good peak shapes for all analyzed lipid classes including acidic lipids. This method is applied for the identification of lipids in real samples of porcine brain and kidney extracts. Copyright © 2016 Elsevier B.V. All rights reserved.
Wu, Haiqing; Peng, Ying; Wang, Shaojie; Wang, Kai; Zhao, Xunchen; Jiang, Fan
2012-12-12
A high performance liquid chromatography-quadrupole time of flight mass spectrometry (HPLC-QTOF-MS) method was employed in investigation of benzbromarone metabolites in rat plasma, urine, feces and bile samples. Meanwhile, the metabolic pathways of benzbromarone in rats were discussed. The identification was achieved on a reversed-phase C(18) column with mobile phase gradient method. The QTOF-MS was operated under full scan of MS or MS/MS in negative mode. The fragments were acquired by raising collision induced dissociation (CID) energy for speculating the structures of parent ions. According to the information from the chromatograms and mass spectra, 17 metabolites were obtained. Among them, the deoxidized phase I metabolites and an array of phase II metabolites-sulfate conjugates detected in the biological samples made the work more significant. Copyright © 2012 Elsevier B.V. All rights reserved.
Kim, Joo-Hyun; Han, Singu; Jeong, Heejeong; Jang, Hayeong; Baek, Seolhee; Hu, Junbeom; Lee, Myungkyun; Choi, Byungwoo; Lee, Hwa Sung
2017-03-22
A thermal gradient distribution was applied to a substrate during the growth of a vacuum-deposited n-type organic semiconductor (OSC) film prepared from N,N'-bis(2-ethylhexyl)-1,7-dicyanoperylene-3,4:9,10-bis(dicarboxyimide) (PDI-CN2), and the electrical performances of the films deployed in organic field-effect transistors (OFETs) were characterized. The temperature gradient at the surface was controlled by tilting the substrate, which varied the temperature one-dimensionally between the heated bottom substrate and the cooled upper substrate. The vacuum-deposited OSC molecules diffused and rearranged on the surface according to the substrate temperature gradient, producing directional crystalline and grain structures in the PDI-CN2 film. The morphological and crystalline structures of the PDI-CN2 thin films grown under a vertical temperature gradient were dramatically enhanced, comparing with the structures obtained from either uniformly heated films or films prepared under a horizontally applied temperature gradient. The field effect mobilities of the PDI-CN2-FETs prepared using the vertically applied temperature gradient were as high as 0.59 cm 2 V -1 s -1 , more than a factor of 2 higher than the mobility of 0.25 cm 2 V -1 s -1 submitted to conventional thermal annealing and the mobility of 0.29 cm 2 V -1 s -1 from the horizontally applied temperature gradient.
Berthod, Alain; Hassoun, Mahmoud
2006-05-26
The retention volumes of solutes in countercurrent chromatography (CCC) are directly proportional to their distribution coefficients, K(D) in the biphasic liquid system used as mobile and stationary phase in the CCC column. The cocurrent CCC method consists in putting the liquid "stationary" phase in slow motion in the same direction as the mobile phase. A mixture of five steroid compounds of widely differing polarities was used as a test mixture to evaluate the capabilities of the method with the biphasic liquid system made of water/methanol/ethyl acetate/heptane 6/5/6/5 (v/v) and a 53 mL CCC column of the coil planet centrifuge type. It is shown that the chromatographic resolution obtained in cocurrent CCC is very good because the solute band broadening is minimized as long as the solute is located inside the "stationary" phase. Pushing the method at its limits, it is demonstrated that the five steroids can still be (partly) separated when the flow rate of the two liquid phases is the same (2 mL/min). This is due to the higher volume of upper phase (72% of the column volume) contained inside the CCC column producing a lower linear speed compared to the aqueous lower phase linear speed. The capabilities of the cocurrent CCC method compare well with those of the gradient elution method in HPLC. Continuous detection is a problem due to the fact that two immiscible liquid phases elute from the column. It was partly solved using an evaporative light scattering detector.
Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi
2014-10-03
Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.
Ren, Aixia; Moon, Changsuk; Zhang, Weiqiang; Sinha, Chandrima; Yarlagadda, Sunitha; Arora, Kavisha; Wang, Xusheng; Yue, Junming; Parthasarathi, Kaushik; Heil-Chapdelaine, Rick; Tigyi, Gabor; Naren, Anjaparavanda P.
2014-01-01
Chemotactic migration of fibroblasts toward growth factors relies on their capacity to sense minute extracellular gradients and respond to spatially confined receptor-mediated signals. Currently, mechanisms underlying the gradient sensing of fibroblasts remain poorly understood. Using single-particle tracking methodology, we determined that a lysophosphatidic acid (LPA) gradient induces a spatiotemporally restricted decrease in the mobility of LPA receptor 2 (LPA2) on chemotactic fibroblasts. The onset of decreased LPA2 mobility correlates to the spatial recruitment and coupling to LPA2-interacting proteins that anchor the complex to the cytoskeleton. These localized PDZ motif-mediated macromolecular complexes of LPA2 trigger a Ca2+ puff gradient that governs gradient sensing and directional migration in response to LPA. Disruption of the PDZ motif-mediated assembly of the macromolecular complex of LPA2 disorganizes the gradient of Ca2+ puffs, disrupts gradient sensing, and reduces the directional migration of fibroblasts toward LPA. Our findings illustrate that the asymmetric macromolecular complex formation of chemoattractant receptors mediates gradient sensing and provides a new mechanistic basis for models to describe gradient sensing of fibroblasts. PMID:25542932
Wyss, R; Bucheli, F
1988-02-26
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17 X 4.6 mm I.D.), filled with C18 Corasil 37-53 micron. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-100 ng/ml was between 1.0 and 4.7% for all compounds.
Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K
2010-02-05
A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarman, Sten, E-mail: sarman@ownit.nu; Wang, Yong-Lei; Laaksonen, Aatto
The self-diffusion coefficients of nematic phases of various model systems consisting of regular convex calamitic and discotic ellipsoids and non-convex bodies such as bent-core molecules and soft ellipsoid strings have been obtained as functions of the shear rate in a shear flow. Then the self-diffusion coefficient is a second rank tensor with three different diagonal components and two off-diagonal components. These coefficients were found to be determined by a combination of two mechanisms, which previously have been found to govern the self-diffusion of shearing isotropic liquids, namely, (i) shear alignment enhancing the diffusion in the direction parallel to the streamlinesmore » and hindering the diffusion in the perpendicular directions and (ii) the distortion of the shell structure in the liquid whereby a molecule more readily can escape from a surrounding shell of nearest neighbors, so that the mobility increases in every direction. Thus, the diffusion parallel to the streamlines always increases with the shear rate since these mechanisms cooperate in this direction. In the perpendicular directions, these mechanisms counteract each other so that the behaviour becomes less regular. In the case of the nematic phases of the calamitic and discotic ellipsoids and of the bent core molecules, mechanism (ii) prevails so that the diffusion coefficients increase. However, the diffusion coefficients of the soft ellipsoid strings decrease in the direction of the velocity gradient because the broadsides of these molecules are oriented perpendicularly to this direction due the shear alignment (i). The cross coupling coefficient relating a gradient of tracer particles in the direction of the velocity gradient and their flow in the direction of the streamlines is negative and rather large, whereas the other coupling coefficient relating a gradient in the direction of the streamlines and a flow in the direction of the velocity gradient is very small.« less
Wade, James H; Bailey, Ryan C
2014-01-07
Refractive index-based sensors offer attractive characteristics as nondestructive and universal detectors for liquid chromatographic separations, but a small dynamic range and sensitivity to minor thermal perturbations limit the utility of commercial RI detectors for many potential applications, especially those requiring the use of gradient elutions. As such, RI detectors find use almost exclusively in sample abundant, isocratic separations when interfaced with high-performance liquid chromatography. Silicon photonic microring resonators are refractive index-sensitive optical devices that feature good sensitivity and tremendous dynamic range. The large dynamic range of microring resonators allows the sensors to function across a wide spectrum of refractive indices, such as that encountered when moving from an aqueous to organic mobile phase during a gradient elution, a key analytical advantage not supported in commercial RI detectors. Microrings are easily configured into sensor arrays, and chip-integrated control microrings enable real-time corrections of thermal drift. Thermal controls allow for analyses at any temperature and, in the absence of rigorous temperature control, obviates extended detector equilibration wait times. Herein, proof of concept isocratic and gradient elution separations were performed using well-characterized model analytes (e.g., caffeine, ibuprofen) in both neat buffer and more complex sample matrices. These experiments demonstrate the ability of microring arrays to perform isocratic and gradient elutions under ambient conditions, avoiding two major limitations of commercial RI-based detectors and maintaining comparable bulk RI sensitivity. Further benefit may be realized in the future through selective surface functionalization to impart degrees of postcolumn (bio)molecular specificity at the detection phase of a separation. The chip-based and microscale nature of microring resonators also make it an attractive potential detection technology that could be integrated within lab-on-a-chip and microfluidic separation devices.
Creasy, Arch; Barker, Gregory; Carta, Giorgio
2017-03-01
A methodology is presented to predict protein elution behavior from an ion exchange column using both individual or combined pH and salt gradients based on high-throughput batch isotherm data. The buffer compositions are first optimized to generate linear pH gradients from pH 5.5 to 7 with defined concentrations of sodium chloride. Next, high-throughput batch isotherm data are collected for a monoclonal antibody on the cation exchange resin POROS XS over a range of protein concentrations, salt concentrations, and solution pH. Finally, a previously developed empirical interpolation (EI) method is extended to describe protein binding as a function of the protein and salt concentration and solution pH without using an explicit isotherm model. The interpolated isotherm data are then used with a lumped kinetic model to predict the protein elution behavior. Experimental results obtained for laboratory scale columns show excellent agreement with the predicted elution curves for both individual or combined pH and salt gradients at protein loads up to 45 mg/mL of column. Numerical studies show that the model predictions are robust as long as the isotherm data cover the range of mobile phase compositions where the protein actually elutes from the column. Copyright © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, James Christopher; Rennie, John Alan; Toevs, James Waldo
The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more informationmore » for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.« less
Model to interpret pulsed-field-gradient NMR data including memory and superdispersion effects.
Néel, Marie-Christine; Bauer, Daniela; Fleury, Marc
2014-06-01
We propose a versatile model specifically designed for the quantitative interpretation of NMR velocimetry data. We use the concept of mobile or immobile tracer particles applied in dispersion theory in its Lagrangian form, adding two mechanisms: (i) independent random arrests of finite average representing intermittent periods of very low velocity zones in the mean flow direction and (ii) the possibility of unexpectedly long (but rare) displacements simulating the occurrence of very high velocities in the porous medium. Based on mathematical properties related to subordinated Lévy processes, we give analytical expressions of the signals recorded in pulsed-field-gradient NMR experiments. We illustrate how to use the model for quantifying dispersion from NMR data recorded for water flowing through a homogeneous grain pack column in single- and two-phase flow conditions.
Herath, H M D R; Shaw, P N; Cabot, P; Hewavitharana, A K
2010-06-15
The high-performance liquid chromatography (HPLC) column is capable of enrichment/pre-concentration of trace impurities in the mobile phase during the column equilibration, prior to sample injection and elution. These impurities elute during gradient elution and result in significant chromatographic peaks. Three types of purified water were tested for their impurity levels, and hence their performances as mobile phase, in HPLC followed by total ion current (TIC) mode of MS. Two types of HPLC-grade water produced 3-4 significant peaks in solvent blanks while LC/MS-grade water produced no peaks (although peaks were produced by LC/MS-grade water also after a few days of standing). None of the three waters produced peaks in HPLC followed by UV-Vis detection. These peaks, if co-eluted with analyte, are capable of suppressing or enhancing the analyte signal in a MS detector. As it is not common practice to run solvent blanks in TIC mode, when quantification is commonly carried out using single ion monitoring (SIM) or single or multiple reaction monitoring (SRM or MRM), the effect of co-eluting impurities on the analyte signal and hence on the accuracy of the results is often unknown to the analyst. Running solvent blanks in TIC mode, regardless of the MS mode used for quantification, is essential in order to detect this problem and to take subsequent precautions. Copyright (c) 2010 John Wiley & Sons, Ltd.
Berridge, Georgina; Chalk, Rod; D’Avanzo, Nazzareno; Dong, Liang; Doyle, Declan; Kim, Jung-In; Xia, Xiaobing; Burgess-Brown, Nicola; deRiso, Antonio; Carpenter, Elisabeth Paula; Gileadi, Opher
2011-01-01
We have developed a method for intact mass analysis of detergent-solubilized and purified integral membrane proteins using liquid chromatography–mass spectrometry (LC–MS) with methanol as the organic mobile phase. Membrane proteins and detergents are separated chromatographically during the isocratic stage of the gradient profile from a 150-mm C3 reversed-phase column. The mass accuracy is comparable to standard methods employed for soluble proteins; the sensitivity is 10-fold lower, requiring 0.2–5 μg of protein. The method is also compatible with our standard LC–MS method used for intact mass analysis of soluble proteins and may therefore be applied on a multiuser instrument or in a high-throughput environment. PMID:21093405
Kalariya, Pradipbhai D; Kumar Talluri, Murali V N; Gaitonde, Vinay D; Devrukhakar, Prashant S; Srinivas, Ragampeta
2014-08-01
The present work describes the systematic development of a robust, precise, and rapid reversed-phase liquid chromatography method for the simultaneous determination of eprosartan mesylate and its six impurities using quality-by-design principles. The method was developed in two phases, screening and optimization. During the screening phase, the most suitable stationary phase, organic modifier, and pH were identified. The optimization was performed for secondary influential parameters--column temperature, gradient time, and flow rate using eight experiments--to examine multifactorial effects of parameters on the critical resolution and generated design space representing the robust region. A verification experiment was performed within the working design space and the model was found to be accurate. This study also describes other operating features of the column packed with superficially porous particles that allow very fast separations at pressures available in most liquid chromatography instruments. Successful chromatographic separation was achieved in less than 7 min using a fused-core C18 (100 mm × 2.1 mm, 2.6 μm) column with linear gradient elution of 10 mM ammonium formate (pH 3.0) and acetonitrile as the mobile phase. The method was validated for specificity, linearity, accuracy, precision, and robustness in compliance with the International Conference on Harmonization Q2 (R1) guidelines. The impurities were identified by liquid chromatography with mass spectrometry. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.
Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M
2006-01-01
A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.
Letica, Jelena; Marković, Slavko; Zirojević, Jelena; Nikolić, Katarina; Agbaba, Danica
2010-01-01
An RP-HPLC method for simultaneous separation and quantification of pantoprazole and its five main impurities in pharmaceutical formulations was developed and validated. The separation was accomplished on a Zorbax Eclipse XDB C18 column (5 microm particle size, 150 x 4.6 mm id) using a gradient with mobile phase A [buffer-acetonitrile (70 + 30, v/v)], and mobile phase B [buffer-acetonitrile (30 + 70, v/v)]. The buffer was 0.01 M ammonium acetate solution with addition of 1 mL triethylamine/L of the solution, adjusted to pH 4.5 with orthophosphoric acid. The eluent flow rate was 1 mL/min, the temperature of the column was 30 degrees C, and the eluate was monitored at 290 nm. Linearity (r = 0.999), recovery (97.6-105.8%), RSD (0.55-1.90%), and LOQ (0.099-1.48 microg/mL) were evaluated and found to be satisfactory. The proposed method can be used for simultaneous identification and quantification of the analyzed compounds in pharmaceutical formulations.
Mei, Chenghan; Li, Bin; Yin, Qiangfeng; Jin, Jing; Xiong, Ting; He, Wenjuan; Gao, Xiujuan; Xu, Rong; Zhou, Piqi; Zheng, Heng; Chen, Hui
2015-07-01
A simple, quick and accurate LC-MS/MS method for the quantification of flurbiprofen in human plasma with indomethacin as internal standard (IS) was developed and validated. Samples were treated with methanol to precipitate proteins, then separated on a Ultimate C18 column (5μm, 2.1×50mm) with a gradient elusion process. Mobile phase A was comprised of water and formic acid, mobile phase B was comprised of acetonitrile and formic acid. Multi reaction monitoring (MRM) signals were saved on a negative ionization electrospray mass spectrometer. The calibration curve showed good linearity in the range of 40.00-10000.00μg/L (r(2)=0.998). Intra-day RE was 0.2-2.2%. Inter-day RE was 0.5-3.4%. The samples showed good stability under the study conditions. No significant matrix effect was observed. The established method was then applied to a bioequivalence study of a flurbiprofen axetil formulation. Copyright © 2015 Elsevier B.V. All rights reserved.
Matysova, Ludmila; Zahalkova, Oxana; Klovrzova, Sylva; Sklubalova, Zdenka; Solich, Petr; Zahalka, Lukas
2015-01-01
A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min(-1) was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances.
2015-01-01
A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min−1 was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances. PMID:25878920
A fourth gradient to overcome slice dependent phase effects of voxel-sized coils in planar arrays.
Bosshard, John C; Eigenbrodt, Edwin P; McDougall, Mary P; Wright, Steven M
2010-01-01
The signals from an array of densely spaced long and narrow receive coils for MRI are complicated when the voxel size is of comparable dimension to the coil size. The RF coil causes a phase gradient across each voxel, which is dependent on the distance from the coil, resulting in a slice dependent shift of k-space. A fourth gradient coil has been implemented and used with the system's gradient set to create a gradient field which varies with slice. The gradients are pulsed together to impart a slice dependent phase gradient to compensate for the slice dependent phase due to the RF coils. However the non-linearity in the fourth gradient which creates the desired slice dependency also results in a through-slice phase ramp, which disturbs normal slice refocusing and leads to additional signal cancelation and reduced field of view. This paper discusses the benefits and limitations of using a fourth gradient coil to compensate for the phase due to RF coils.
Mobility of large woody debris (LWD) jams in a low gradient channel
NASA Astrophysics Data System (ADS)
Curran, Joanna C.
2010-04-01
Mobility of large woody debris (LWD) in low gradient channels is an important but often overlooked transport process. The majority of studies on LWD have focused on its role in geomorphic and ecologic river processes. When jams extend across the width of the channel, they have the potential to retain sediment and alter the channel profile. When jams obstruct only a portion of the channel, they can re-direct flow, altering patterns of scour and deposition. The boundary complexity created by LWD has a recognized role in riverine ecosystems which has led to programs of replacing LWD in-channel corridors where it was previously removed. Although LWD jams are common in rivers around the world, they have been studied most intensely in steep, forested channel reaches where they are often found to be stable channel features. It is not fully known how much of the information on LWD from steep forested channels will transfer to other channel types. Whereas it may be reasonable to assume that the ecological benefits of LWD are similar in low gradient channels, research has shown that a much higher rate of LWD transport occurs in low gradient channels, with jams mobilized on timescales of 10 0-10 2 years. This study evaluates the distribution and mobility of LWD over 72 km of the San Antonio River, a low gradient channel in southeast Texas. LWD jam locations were identified for 2003 and 2007 using a combination of aerial photography and field mapping. Each jam was cataloged according to its location in the channel cross-section and the amount of channel area blocked. During the four-year period, all the LWD jams were mobilized, including those jams extending across the channel width. Although easily mobilized, 34 jams re-form in the same locations, creating 34 channel locations with persistent LWD jams. Data from the San Antonio River are applied to two models developed to predict LWD mobility and transport distances to assess the applicability of each model to a low gradient channel. The locations of stable (or recurring) LWD jams were matched to model results where predicted LWD transport distances were equal to measured LWD jam spacing. Model results showed good agreement with the mean and median spacing of LWD jams when given input parameters specific to the channel and wood species. The ability to predict where LWD jams will persist over time in a low gradient channel has application in watershed management. Persistent LWD jams can exert a greater influence on channel morphology and may require active management.
Zhu, Haitao; Nie, Binbin; Liu, Hua; Guo, Hua; Demachi, Kazuyuki; Sekino, Masaki; Shan, Baoci
2016-05-01
Phase map cross-correlation detection and quantification may produce highlighted signal at superparamagnetic iron oxide nanoparticles, and distinguish them from other hypointensities. The method may quantify susceptibility change by performing least squares analysis between a theoretically generated magnetic field template and an experimentally scanned phase image. Because characteristic phase recognition requires the removal of phase wrap and phase background, additional steps of phase unwrapping and filtering may increase the chance of computing error and enlarge the inconsistence among algorithms. To solve problem, phase gradient cross-correlation and quantification method is developed by recognizing characteristic phase gradient pattern instead of phase image because phase gradient operation inherently includes unwrapping and filtering functions. However, few studies have mentioned the detectable limit of currently used phase gradient calculation algorithms. The limit may lead to an underestimation of large magnetic susceptibility change caused by high-concentrated iron accumulation. In this study, mathematical derivation points out the value of maximum detectable phase gradient calculated by differential chain algorithm in both spatial and Fourier domain. To break through the limit, a modified quantification method is proposed by using unwrapped forward differentiation for phase gradient generation. The method enlarges the detectable range of phase gradient measurement and avoids the underestimation of magnetic susceptibility. Simulation and phantom experiments were used to quantitatively compare different methods. In vivo application performs MRI scanning on nude mice implanted by iron-labeled human cancer cells. Results validate the limit of detectable phase gradient and the consequent susceptibility underestimation. Results also demonstrate the advantage of unwrapped forward differentiation compared with differential chain algorithms for susceptibility quantification at high-concentrated iron accumulation. Copyright © 2015 Elsevier Inc. All rights reserved.
Intrinsic mobility limit for anisotropic electron transport in Alq3.
Drew, A J; Pratt, F L; Hoppler, J; Schulz, L; Malik-Kumar, V; Morley, N A; Desai, P; Shakya, P; Kreouzis, T; Gillin, W P; Kim, K W; Dubroka, A; Scheuermann, R
2008-03-21
Muon spin relaxation has been used to probe the charge carrier motion in the molecular conductor Alq3 (tris[8-hydroxy-quinoline] aluminum). At 290 K, the magnetic field dependence of the muon spin relaxation corresponds to that expected for highly anisotropic intermolecular electron hopping. Intermolecular mobility in the fast hopping direction has been found to be 0.23+/-0.03 cm2 V-1 s(-1) in the absence of an electric- field gradient, increasing to 0.32+/-0.06 cm2 V-1 s(-1) in an electric field gradient of 1 MV m(-1). These intrinsic mobility values provide an estimate of the upper limit for mobility achievable in bulk material.
Xu, Yu; Wang, DanDan; Tang, Lan; Wang, Jian
2017-10-25
Eleven unknown allergic impurities in cefodizime, cefmenoxime and cefonicid were separated and characterized by a trap-free two-dimensional high performance size exclusion chromatography (HPSEC) and reversed phase liquid chromatography (RP-HPLC) coupled to high resolution ion trap/time-of-flight mass spectrometry (2D-HPSEC×LC-IT-TOF MS) with positive and negative modes of electrospray ionization method. Separation and characterization the allergic polymerized impurities in β-lactam antibiotics were on the basis of column-switching technique which effectively combined the advantages of HPSEC and the ability of RP-HPLC to identify the special impurities. In the first dimension HPSEC, the column was Xtimate SEC-120 analytical column (7.8mm×30cm, 5μm), and the gradient elution used pH 7.0 buffer-acetonitrile as mobile phase And the second dimension analytical column was ZORBAX SB-C18 (4.6×150mm, 3.5μm) with ammonium formate solution (10mM) and ammonium formate (8mM) in [acetonitrile-water (4:1, v/v)] solution as mobile phase. Structures of eleven unknown impurities were deduced based on the high resolution MS n data with both positive and negative modes, in which nine impurities were polymerized impurities. The forming mechanism of β-lactam antibiotic polymerization in cephalosporins was also studied. The question on incompatibility between non-volatile salt mobile phase and mass spectrometry was solved completely by multidimensional heart-cutting approaches and online demineralization technique, which was worthy of widespread use and application for the advantages of stability and repeatability. Copyright © 2017. Published by Elsevier B.V.
Asea, P A; Patterson, J R; Korsrud, G O; Dowling, P M; Boison, J O
2001-01-01
A new and sensitive liquid chromatography-ultra violet method with a detection limit of 6 ng/g (ppb) and a limit of quantification of 15 ng/g was developed for the determination of flunixin residues in bovine muscle tissue. Flunixin in homogenized animal tissue was extracted with acetonitrile after enzyme digestion. The tissue digest (extract) was then cleaned up on a solid-phase extraction cartridge and eluted with acidified hexane. After the eluate was evaporated to dryness under nitrogen at 55 degrees C, the residue was reconstituted in 1 mL mobile phase solution and analyzed by reversed-phase gradient chromatography with UV detection at 285 nm. The method was then applied in a survey study of slaughter animals to determine whether flunixin is being used in an off-label manner for veal and beef production in Canada.
Irakli, Maria N; Samanidou, Victoria F; Papadoyannis, Ioannis N
2012-03-07
The separation and determination of tocopherols (Ts) and tocotrienols (T3s) by reversed-phase high-performance liquid chromatography with fluorescence detection has been developed and validated after optimization of various chromatographic conditions and other experimental parameters. Analytes were separated on a PerfectSil Target ODS-3 (250 × 4.6 mm, 3 μm) column filled with a novel sorbent material of ultrapure silica gel. The separation of Ts and T3s was optimized in terms of mobile-phase composition and column temperature on the basis of the best compromise among efficiency, resolution, and analysis time. Using a gradient elution of mobile phase composed of isopropanol/water and 7 °C column temperature, a satisfactory resolution was achieved within 62 min. For the quantitative determination, α-T acetate (50 μg/mL) was used as the internal standard. Detection limits ranged from 0.27 μg/mL (γ-T) to 0.76 μg/mL (γ-T3). The validation of the method was examined performing intraday (n = 5) and interday (n = 3) assays and was found to be satisfactory, with high accuracy and precision results. Solid-phase extraction provided high relative extraction recoveries from cereal samples: 87.0% for γ-T3 and 115.5% for δ-T. The method was successfully applied to cereals, such as durum wheat, bread wheat, rice, barley, oat, rye, and corn.
Zhu, Haitao; Demachi, Kazuyuki; Sekino, Masaki
2011-09-01
Positive contrast imaging methods produce enhanced signal at large magnetic field gradient in magnetic resonance imaging. Several postprocessing algorithms, such as susceptibility gradient mapping and phase gradient mapping methods, have been applied for positive contrast generation to detect the cells targeted by superparamagnetic iron oxide nanoparticles. In the phase gradient mapping methods, smoothness condition has to be satisfied to keep the phase gradient unwrapped. Moreover, there has been no discussion about the truncation artifact associated with the algorithm of differentiation that is performed in k-space by the multiplication with frequency value. In this work, phase gradient methods are discussed by considering the wrapping problem when the smoothness condition is not satisfied. A region-growing unwrapping algorithm is used in the phase gradient image to solve the problem. In order to reduce the truncation artifact, a cosine function is multiplied in the k-space to eliminate the abrupt change at the boundaries. Simulation, phantom and in vivo experimental results demonstrate that the modified phase gradient mapping methods may produce improved positive contrast effects by reducing truncation or wrapping artifacts. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zaitsev, Vladimir Y.; Matveyev, Alexander L.; Matveev, Lev A.; Gelikonov, Grigory V.; Sovetsky, Aleksandr A.; Vitkin, Alex
2016-11-01
In compressional optical coherence elastography, phase-variation gradients are used for estimating quasistatic strains created in tissue. Using reference and deformed optical coherence tomography (OCT) scans, one typically compares phases from pixels with the same coordinates in both scans. Usually, this limits the allowable strains to fairly small values < to 10-3, with the caveat that such weak phase gradients may become corrupted by stronger measurement noises. Here, we extend the OCT phase-resolved elastographic methodology by (1) showing that an order of magnitude greater strains can significantly increase the accuracy of derived phase-gradient differences, while also avoiding error-phone phase-unwrapping procedures and minimizing the influence of decorrelation noise caused by suprapixel displacements, (2) discussing the appearance of artifactual stiff inclusions in resultant OCT elastograms in the vicinity of bright scatterers due to the amplitude-phase interplay in phase-variation measurements, and (3) deriving/evaluating methods of phase-gradient estimation that can outperform conventionally used least-square gradient fitting. We present analytical arguments, numerical simulations, and experimental examples to demonstrate the advantages of the proposed optimized phase-variation methodology.
Yi, Yan; Zhang, Qing-Wen; Li, Song-Lin; Wang, Ying; Ye, Wen-Cai; Zhao, Jing; Wang, Yi-Tao
2012-11-15
A pressurised liquid extraction (PLE) and high performance liquid chromatography (HPLC) method was developed for simultaneous quantification of six major flavonoids in edible flower of Hylocereus undatus. In order to achieve the baseline separation of two pairs of isomers, the HPLC conditions were optimised with different kind of reversed phase columns and mobile phase gradient programs. In addition, the solvent concentration, extraction temperature, extraction time and flush cycle for PLE were also optimised. Zorbax SB-C8 (100×2.1 mm, 1.8 μm) column was chosen with acetonitrile and water containing 0.1% trifluoroacetic acid as mobile phase, the six analytes were eluted with baseline separation. The calibration curves showed good linearity (r(2)>0.9994) with LODs and LOQs less than 0.90 and 3.60 ng respectively. The RSDs for intra- and inter-day repeatability was not more than 1.09% and 1.79% respectively. The overall recovery of the assay was 96.9-105.2%. The sample was stable for at least 12 h. The newly established method was successfully applied to quantify six flavonoids in different parts of "Bawanghua", and the commercial samples from different locations. Copyright © 2012 Elsevier Ltd. All rights reserved.
A Holistic Approach to Understanding the Desorption of Phosphorus in Soils.
Menezes-Blackburn, Daniel; Zhang, Hao; Stutter, Marc; Giles, Courtney D; Darch, Tegan; George, Timothy S; Shand, Charles; Lumsdon, David; Blackwell, Martin; Wearing, Catherine; Cooper, Patricia; Wendler, Renate; Brown, Lawrie; Haygarth, Philip M
2016-04-05
The mobility and resupply of inorganic phosphorus (P) from the solid phase were studied in 32 soils from the UK. The combined use of diffusive gradients in thin films (DGT), diffusive equilibration in thin films (DET) and the "DGT-induced fluxes in sediments" model (DIFS) were adapted to explore the basic principles of solid-to-solution P desorption kinetics in previously unattainable detail. On average across soil types, the response time (Tc) was 3.6 h, the desorption rate constant (k-1) was 0.0046 h(-1), and the desorption rate was 4.71 nmol l(-1) s(-1). While the relative DGT-induced inorganic P flux responses in the first hour is mainly a function of soil water retention and % Corg, at longer times it is a function of the P resupply from the soil solid phase. Desorption rates and resupply from solid phase were fundamentally influenced by P status as reflected by their high correlation with P concentration in FeO strips, Olsen, NaOH-EDTA and water extracts. Soil pH and particle size distribution showed no significant correlation with the evaluated mobility and resupply parameters. The DGT and DET techniques, along with the DIFS model, were considered accurate and practical tools for studying parameters related to soil P desorption kinetics.
A three-ions model of electrodiffusion kinetics in a nanochannel
NASA Astrophysics Data System (ADS)
Sebechlebská, Táňa; Neogrády, Pavel; Valent, Ivan
2016-10-01
Nanoscale electrodiffusion transport is involved in many electrochemical, technological and biological processes. Developments in computer power and numerical algorithms allow for solving full time-dependent Nernst-Planck and Poisson equations without simplifying approximations. We simulate spatio-temporal profiles of concentration and electric potential changes after a potential jump in a 10 nm channel with two cations (with opposite concentration gradients and different mobilities) and one anion (of uniform concentration). The temporal dynamics shows three exponential phases and damped oscillations of the electric potential. Despite the absence of surface charges in the studied model, an asymmetric current-voltage characteristic was observed.
Chromatographic determination of the diffusion coefficients of light hydrocarbons in polymers
NASA Astrophysics Data System (ADS)
Yakubenko, E. E.; Korolev, A. A.; Chapala, P. P.; Bermeshev, M. V.; Kanat'eva, A. Yu.; Kurganov, A. A.
2017-01-01
Gas-chromatographic determination of the diffusion coefficients that allows for the compressibility of the mobile phase has been suggested. The diffusion coefficients were determined for light hydrocarbons C1-C4 in four polymers with a high free volume, which are candidates for use as gas-separating membranes. The diffusion coefficients calculated from chromatographic data were shown to be one or two orders of magnitude smaller than the values obtained by the membrane method. This may be due to the presence of an additional flow through the membrane caused by the pressure gradient across the membrane in membrane methods.
Foulon, Catherine; Di Giulio, Pauline; Lecoeur, Marie
2018-01-26
Supercritical fluid chromatography (SFC) is commonly used for the analysis of non-polar compounds, but remains poorly explored for the separation of polar and ionized molecules. In this paper, SFC has been investigated for the separation of 14 inorganic ions sampled in aqueous solutions. Four polar stationary phases were first screened using CO 2 -methanol-based mobile phases containing water or different acidic or basic additives, in order to select the most efficient conditions for the simultaneous retention of inorganic cations and anions and to favor their detection using evaporative light scattering detector (ELSD). Orthogonal selectivity was obtained depending on the stationary phase used: whereas anions are less retained on HILIC stationary phase, 2-ethylpyridine (2-EP) stationary phase exhibits strong interaction for anions. Best results were obtained under gradient elution mode using a 2-EP stationary phase and by adding 0.2% triethylamine in the CO 2 -methanol-based mobile phase. The composition of the injection solvent was also investigated. The results showed that a methanolic sample containing a percentage of water not exceeding 20% does not affect the analytical performances obtained on 2-EP. Moreover, the presence of triethylamine in the injection solvent contributes to eliminate peaks shoulders. Among the 14 inorganic ions tested, three cations (Li + , Ca 2+ and Mg 2+ ) and five anions (Cl - , Br - , NO 3 - , I - , SCN - ) were totally resolved in 15 min. NO 3 - and NO 2 - still coeluted in the final optimized conditions. The other investigated ions were either strongly retained on the stationary phase or not detected by the ELSD. Copyright © 2017 Elsevier B.V. All rights reserved.
Spórna-Kucab, Aneta; Garrard, Ian; Ignatova, Svetlana; Wybraniec, Sławomir
2015-02-06
Betalains, natural plant pigments, are beneficial compounds due to their antioxidant and possible chemoprotective properties. A mixture of betalains: betanin/isobetanin, decarboxybetanins and neobetanin from processed red beet roots (Beta vulgaris L.) juice was separated in food-grade, gradient solvent systems using high-performance counter-current chromatography (HPCCC). The decarboxylated and dehydrogenated betanins were obtained by thermal degradation of betanin/isobetanin from processed B. vulgaris L. juice under mild conditions. Two solvent systems (differing in their composition by phosphoric acid and ethanol volume gradient) consisting of BuOH-EtOH-NaClsolution-H2O-H3PO4 (v/v/v/v/v, 1300:200-1000:1300:700:2.5-10) in the 'tail-to-head' mode were run. The flow rate of the mobile phase (organic phase) was 1.0 or 2.0 ml/min and the column rotation speed was 1,600 rpm (20°C). The retention of the solvent system stationary phase (aqueous phase) was ca. 80%. The system with the acid and ethanol volume gradient consisting of BuOH-EtOH-NaClsolution-H2O-H3PO4 (v/v/v/v/v, 1300:200-240:1300:700:2.5-4.5) pumped at 2.0 ml/min was the most effective for a separation of betanin/isobetanin, 17-decarboxy-betanin/-isobetanin, 2-decarboxy-betanin/-isobetanin, 2,17-bidecarboxy-betanin/-isobetanin pairs as well as neobetanin. The pigments were detected by LC-DAD and LC-MS. The results are crucial in the application of completely food-grade solvent systems in separation of food-grade compounds as well, and the systems can possibly be extended to other ionizable and polar compounds with potential health benefits. In particular, the method is applicable for the isolation and purification of betalains present in such rich sources as B. vulgaris L. roots as well as cacti fruits and Amaranthaceae flowering plants due to modification possibilities of the solvent systems polarity. Copyright © 2014 Elsevier B.V. All rights reserved.
Speciation of inorganic selenium and selenoamino acids by an HPLC-UV-HG-AFS system.
Ipolyi, I; Corns, W; Stockwell, P; Fodor, P
2001-01-01
For the on-line speciation of selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (SeEt), selenite (Se(IV)) and selenate (Se(VI)), a high-performance liquid chromatography-UV irradiation-hydride generation-atomic fluorescence spectro- metric method is described. Separation was carried out on a conventional reversed-phase C18 column modified with didodecyl- dimethylammonium bromide with gradient elution applying two concentrations of ammonium acetate as the mobile phase. UV irradiation and hydride generation parameters were optimized. The obtained detection limits for SeCys, SeMet, SeEt, Se(IV) and Se(VI) were 0.31, 0.43, 0.7, 0.44 and 0.32 ng ml(-1), respectively, using a 100-microl loop. The method was tested with spiked mineral water and two volunteers' urine samples.
Speciation of inorganic selenium and selenoamino acids by an HPLC-UV-HG-AFS system
Ipolyi, I.; Corns, W.; Stockwell, P.; Fodor, P.
2001-01-01
For the on-line speciation of selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (SeEt), selenite (Se(IV)) and selenate (Se(VI)), a high-performance liquid chromatography-UV irradiation-hydride generation-atomic fluorescence spectro- metric method is described. Separation was carried out on a conventional reversed-phase C18 column modified with didodecyl- dimethylammonium bromide with gradient elution applying two concentrations of ammonium acetate as the mobile phase. UV irradiation and hydride generation parameters were optimized. The obtained detection limits for SeCys, SeMet, SeEt, Se(IV) and Se(VI) were 0.31, 0.43, 0.7, 0.44 and 0.32 ng ml−1, respectively, using a 100-wl loop. The method was tested with spiked mineral water and two volunteers' urine samples. PMID:18924707
Fundamentals of capillary electrochromatography: migration behavior of ionized sample components.
Xiang, Rong; Horváth, Csaba
2002-02-15
The mechanism of separating charged species by capillary electrochromatography (CEC) was modeled with the conditions of ideal/linear chromatography by using a simple random walk. The most novel aspect of the work rests with the assumption that in sufficiently high electric field ionized sample components can also migrate in the adsorbed state on the ionized surface of the stationary phase. This feature of CEC leads to the introduction of three dimensionless parameters: alpha, reduced mobility of a sample component with the electrosmotic mobility as the reference; beta, the CEC retention factor; and gamma, the ratio of the electrophoretic migration velocity and the velocity of surface electrodiffusion. Since the interplay of retentive and electrophoretic forces determines the overall migration velocity, the separation mechanism in CEC is governed by the relative importance of the above parameters. The model predicts conditions under which the features of the CEC system engender migration behavior that manifests itself in a relatively narrow elution window and in a gradient like elution pattern in the separation of peptides and proteins by using pro forma isocratic CEC. It is believed that such elution patterns, which resemble those obtained by the use of external gradient of the eluent, are brought about by the formation of an internal gradient in the CEC system that gave rise to concomitant peak compression. The peculiarities of CEC are discussed in the three operational modalities of the technique: co-current, countercurrent, and co-counter CEC. The results suggest that CEC, which is often called "liquid chromatography on electrophoretic platform" is an analytical tool with great potential in the separation of peptides and proteins.
Liu, Min; Li, Xiaolin; Bie, Wei; Wang, Minglin; Feng, Qian
2011-02-01
A new method was established for the determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography (SPE-HPLC). The samples were extracted by methanol-water (1:1, v/v) and purified by a solid phase extraction column. Then, the chromatographic separation was achieved on a Luna C18 column by linear gradient elution. The mobile phase was 10 mmol/L ammonium acetate-acetonitrile (containing 1% acetic acid). The results showed that the 15 industrial synthetic dyes can be separated efficiently. The recoveries of the 15 industrial synthetic dyes spiked in condiment were between 84.6% and 114.2% with the relative standard deviations of 0.9% - 10.3%. The limits of detection of this method was 0.05 - 0.18 mg/kg for the 15 industrial synthetic dyes. The method is simple, sensitive, accurate, repeatable and can be used for simultaneous determination of the 15 illegally added industrial synthetic dyes.
Ma, Li; Yang, Zhaoguang; Tang, Jie; Wang, Lin
2016-06-01
The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion-exchange column run by high-performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4 HCO3 at pH 8.6 as mobile phase A and 4 mM NH4 HCO3 , 40 mM NH4 NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish
2012-01-01
Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475
Baker, Andrew M.; Babu, Siddharth Komini; Mukundan, Rangachary; ...
2017-09-21
Ion mobility and diffusivity coefficients were determined for cerium ions in Nafion XL perfluorosulfonic acid ionomer membranes at 100% and 50% relative humidity in a conductivity cell using a hydrogen pump. We quantified Ce ion migration profiles as a function of charge transfer through the cell using X-ray fluorescence (XRF). To decouple simultaneous effects of Ce ion mobility and back-diffusion which occur due to potential and concentration gradients, respectively, a one-dimensional model was developed and fit to these intermittent XRF profiles. The resulting mobility and diffusivity coefficients demonstrate the dramatic effects of potential and concentration gradients on Ce ion migrationmore » during PEM fuel cell operation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Andrew M.; Babu, Siddharth Komini; Mukundan, Rangachary
Ion mobility and diffusivity coefficients were determined for cerium ions in Nafion XL perfluorosulfonic acid ionomer membranes at 100% and 50% relative humidity in a conductivity cell using a hydrogen pump. We quantified Ce ion migration profiles as a function of charge transfer through the cell using X-ray fluorescence (XRF). To decouple simultaneous effects of Ce ion mobility and back-diffusion which occur due to potential and concentration gradients, respectively, a one-dimensional model was developed and fit to these intermittent XRF profiles. The resulting mobility and diffusivity coefficients demonstrate the dramatic effects of potential and concentration gradients on Ce ion migrationmore » during PEM fuel cell operation.« less
Allen, R. D.; Roslansky, J. D.
1958-01-01
Sustained locomotion in Amoeba proteus and Amoeba dubia results in the establishment of a measureable gradient of refractive index along the anterior-posterior axis of the cell, provided thickness of the specimens is kept constant by even compression under a selected coverglass supported by quartz beams of uniform diameter. The tail region of the ameba develops a higher refractive index, indicative of from 6 to 40 per cent more organic matter (expressed as protein) there than present in the front. This gradient fades on cessation of movement. The average protein concentrations in the crystal-free tails and fronts of 15 A. proteus were 3.9 and 3.4 per cent, respectively. In individual experiments, the tail-front difference ranged from one to eight times the accuracy of the method. Since the gradient of refractive index was shown not to result from extraction of water from the tail by the contractile vacuole, it was interpreted as displacement of water toward the anterior part of the cell during movement. It is suggested that contraction of the ectoplasm drives forward a "tide" of syncretic fluid, the anterior border of which is visible as the hyaline cap, which contains less than 1 per cent protein. The movement of the granular endoplasm into the hyaline cap would then complete the cycle by imbibition of the fluid tide. The theoretical positions of Pantin and of Dellinger have been combined in the proposal that ameba cytoplasm consists of a network of a contractile phase which is able to expel (by syneresis) a highly mobile fluid phase. Some other possible interpretations are discussed. PMID:13587543
Effect of interface deformability on thermocapillary motion of a drop in a tube
NASA Astrophysics Data System (ADS)
Mahesri, S.; Haj-Hariri, H.; Borhan, A.
2014-03-01
The effect of an externally imposed axial temperature gradient on the mobility and deformation of a drop in an otherwise stagnant liquid within an insulated cylindrical tube is investigated. In the absence of bulk transport of momentum and energy, the boundary integral technique is used to obtain the flow and temperature fields inside and outside the deformable drop. The steady drop shapes and the corresponding migration velocities are examined over a wide range of the dimensionless parameters. The steady drop shape is nearly spherical for dimensionless drop sizes <0.5, but becomes slightly elongated in the axial direction for drop sizes comparable to tube diameter. The adverse effect of drop deformation on the effective temperature gradient driving the motion is slightly more pronounced than its favorable effect of reducing drag, thereby leading to a slight reduction in drop mobility with increasing drop deformation. Increasing the viscosity ratio reduces drop deformation and leads to a slight enhancement in the relative mobility (with respect to free thermocapillary motion) of confined drops. When the drop fluid has a lower thermal conductivity than the exterior phase, the presence of the thermally-insulating wall increases the thermal driving force for drop motion (compared to that for the same drop in unbounded domain) by causing more pronounced bending of the isotherms toward the drop. However, the favorable thermal effect of the confining wall is overwhelmed by its retarding hydrodynamic effect, causing the confined drop to always move slower than its unbounded counterpart regardless of the value of the thermal conductivity ratio.
Gupta, Shweta; Kesarla, Rajesh; Chotai, Narendra; Omri, Abdelwahab
2017-01-01
Efavirenz is an anti-viral agent of non-nucleoside reverse transcriptase inhibitor category used as a part of highly active retroviral therapy for the treatment of infections of human immune deficiency virus type-1. A simple, sensitive and rapid reversed-phase high performance liquid chromatographic gradient method was developed and validated for the determination of efavirenz in plasma. The method was developed with high performance liquid chromatography using Waters X-Terra Shield, RP18 50 x 4.6 mm, 3.5 μm column and a mobile phase consisting of phosphate buffer pH 3.5 and Acetonitrile. The elute was monitored with the UV-Visible detector at 260 nm with a flow rate of 1.5 mL/min. Tenofovir disoproxil fumarate was used as internal standard. The method was validated for linearity, precision, accuracy, specificity, robustness and data obtained were statistically analyzed. Calibration curve was found to be linear over the concentration range of 1-300 μg/mL. The retention times of efavirenz and tenofovir disoproxil fumarate (internal standard) were 5.941 min and 4.356 min respectively. The regression coefficient value was found to be 0.999. The limit of detection and the limit of quantification obtained were 0.03 and 0.1 μg/mL respectively. The developed HPLC method can be useful for quantitative pharmacokinetic parameters determination of efavirenz in plasma.
Beeston, Michael Philip; Glass, Hylke Jan; van Elteren, Johannes Teun; Slejkovec, Zdenka
2007-09-19
A new method has been developed to analyse the mobility of elements within soils employing counter-current flow soil contacting in a fluidised bed (FB) column. This method alleviates the problem of irreproducible peaks suffered by state-of-the-art micro-column techniques as a result of particle compaction. Reproducible extraction profiles are produced through the leaching of soil with a linear gradient of 0.05 mol L(-1) ammonium sulphate to 0.11 mol L(-1) acetic acid using a high pressure liquid chromatography (HPLC) quaternary pump, and the continuous monitoring of the elements in the leachate with inductively coupled plasma mass spectrometry (ICP-MS). Quantification of the procedure is achieved with an external flow injection (FI) calibration method. Flow rate and FB column length were investigated as critical parameters to the efficiency of the extraction methodology. It was found that an increase in the column length from 10 to 20 cm using a flow rate of 0.15 mL min(-1) produced the same increase in extracted elemental concentration as an increase in flow rate from 0.15 to 0.30 mL min(-1). In both examples, the increase in the concentration of elements leached from the soil may be ascribed to the increase in the concentration gradient between the solid and liquid. The exhaustive nature of the technique defines the maximum leachable concentration within the operationally defined leaching parameters of the exchangeable phase, providing a more accurate assessment of the risk associated with the elements in the soil for the phase providing the greatest risk to the environment. The multi-elemental high sensitivity nature of the on-line detector provides an accurate determination of the associations present between the elements in the soil, and the identification of multiple phases within the exchangeable phase through the presence of multiple peaks in the extraction profiles. It is possible through the deconvolution of these extraction profiles that the concentration corresponding to the peaks identified can be defined.
Zauner, Jordan; Lusk, Ryan; Koski, Steven; Poe, Donald P
2012-11-30
When a packed column is operated at temperatures and pressures near the critical point in supercritical fluid chromatography, the thermal environment in which it is placed has a significant impact on retention and efficiency. We measured the retention factors, plate heights, and related parameters for elution of a test mixture of alkylbenzenes with 5% methanol/95% carbon dioxide mobile phase on a 250 mm × 4.6 mm i.d. column packed with 5-micron Luna-C18 particles. Separations were performed at outlet pressures from 100 to 150 bar and a column oven temperature of 323K. For a bare column thermostated with convective air, significant efficiency losses were observed for outlet pressures equal to or less than 120 bar. These large efficiency losses are attributed to radial temperature gradients. Addition of foam insulation resulted in significant improvements in efficiency. Operating the column in still air using a commercially available column heater provided the best overall performance, with no measurable efficiency loss over the entire range of pressures studied. A reduced plate height of 1.88 was obtained at an optimum flow rate of 3.0 mL/min at 100 bar outlet pressure and with the temperature of the incoming mobile phase set approximately 2.3K above the temperature of the column oven. Retention time repeatability for all three thermal conditions was equal to or less than 0.5% RSD. These results demonstrate that it is possible to perform fast, efficient separations with excellent repeatability using SFC under near-critical conditions if the thermal environment is optimized to minimize the generation of radial temperature gradients. Copyright © 2012 Elsevier B.V. All rights reserved.
Capillary-Physics Mechanism of Elastic-Wave Mobilization of Residual Oil
NASA Astrophysics Data System (ADS)
Beresnev, I. A.; Pennington, W. D.; Turpening, R. M.
2003-12-01
Much attention has been given to the possibility of vibratory mobilization of residual oil as a method of enhanced recovery. The common features of the relevant applications have nonetheless been inconsistency in the results of field tests and the lack of understanding of a physical mechanism that would explain variable experiences. Such a mechanism can be found in the physics of capillary trapping of oil ganglia, driven through the pore channels by an external pressure gradient. Entrapping of ganglia occurs due to the capillary pressure building on the downstream meniscus entering a narrow pore throat. The resulting internal-pressure imbalance acts against the external gradient, which needs to exceed a certain threshold to carry the ganglion through. The ganglion flow thus exhibits the properties of the Bingham (yield-stress) flow, not the Darcy flow. The application of vibrations is equivalent to the addition of an oscillatory forcing to the constant gradient. When this extra forcing acts along the gradient, an instant "unplugging" occurs, while, when the vibration reverses direction, the flow is plugged. This asymmetry results in an average non-zero flow over one period of vibration, which explains the mobilization effect. The minimum-amplitude and maximum-frequency thresholds apply for the mobilization to occur. When the vibration amplitude exceeds a certain "saturation" level, the flow returns to the Darcy regime. The criterion of the mobilization of a particular ganglion involves the parameters of both the medium (pore geometry, interfacial and wetting properties, fluid viscosity) and the oscillatory field (amplitude and frequency). The medium parameters vary widely under natural conditions. It follows that an elastic wave with a given amplitude and frequency will always produce a certain mobilization effect, mobilizing some ganglia and leaving others intact. The exact macroscopic effect is hard to predict, as it will represent a response of the populations of ganglia with unknown parameter distributions. The variability of responses to vibratory stimulation should thus be expected.
NASA Astrophysics Data System (ADS)
Sarman, Sten; Wang, Yong-Lei; Laaksonen, Aatto
2016-02-01
The self-diffusion coefficients of nematic phases of various model systems consisting of regular convex calamitic and discotic ellipsoids and non-convex bodies such as bent-core molecules and soft ellipsoid strings have been obtained as functions of the shear rate in a shear flow. Then the self-diffusion coefficient is a second rank tensor with three different diagonal components and two off-diagonal components. These coefficients were found to be determined by a combination of two mechanisms, which previously have been found to govern the self-diffusion of shearing isotropic liquids, namely, (i) shear alignment enhancing the diffusion in the direction parallel to the streamlines and hindering the diffusion in the perpendicular directions and (ii) the distortion of the shell structure in the liquid whereby a molecule more readily can escape from a surrounding shell of nearest neighbors, so that the mobility increases in every direction. Thus, the diffusion parallel to the streamlines always increases with the shear rate since these mechanisms cooperate in this direction. In the perpendicular directions, these mechanisms counteract each other so that the behaviour becomes less regular. In the case of the nematic phases of the calamitic and discotic ellipsoids and of the bent core molecules, mechanism (ii) prevails so that the diffusion coefficients increase. However, the diffusion coefficients of the soft ellipsoid strings decrease in the direction of the velocity gradient because the broadsides of these molecules are oriented perpendicularly to this direction due the shear alignment (i). The cross coupling coefficient relating a gradient of tracer particles in the direction of the velocity gradient and their flow in the direction of the streamlines is negative and rather large, whereas the other coupling coefficient relating a gradient in the direction of the streamlines and a flow in the direction of the velocity gradient is very small.
Xuan, Xueyi; Huang, Lina; Pan, Xiaoling; Li, Ning
2013-02-01
A pH/organic solvent double-gradient mode in reversed-phase high performance liquid chromatography (HPLC) has been established as a new approach to the simultaneous determination of acetaminophen, caffeine, salicylamide, pseudoephedrine hydrochloride and triprolidine hydrochloride in paracetamol triprolidine hydrochloride and pseudoephedrine hydrochloride tablets. Through the optimization of the organic solvent gradient mode and pH/organic solvent double-gradient mode, the optimum double-gradient HPLC system of the five cold medicine ingredients has been built. The determination was carried out on a Diamonsiol C18 column (250 mm x 4.6 mm, 5 microm). The mobile phase consisted of methanol, 0.05 mol/L ammonium acetate solution and 0.08 mol/L acetic acid solution. The column temperature was set at 30 degrees C. The flow rate was 1.0 mL/min. The sample was measured at multiple wavelengths: 0-6 min, 280 nm; 6-7 min, 257 nm; 7-14 min, 280 nm; 14 min, 233 nm. The separation of the five cold medicine ingredients in the tablets was achieved in 25.5 min. The linear ranges of acetaminophen, pseudoephedrine hydrochloride, caffeine, salicylamide and triprolidine hydrochloride were 0.055 -0.998 g/L, 0.053-0.946 g/L, 0.007-0.129 g/L, 0.035-0.622 g/L and 0.002-0.039 g/L, respectively, with their correlation coefficients greater than 0.999 0. The detection limits (S/N = 3) were 0.09, 6, 0.02, 0.128 and 0.02 mg/L, respectively. Their mean recoveries were 97.9%-102.8%. The advantage of the method is the simultaneous determination of acidic, neutral and basic compounds. It also can improve the column efficiency of the analyte, compress the half-peak width and reduce the trailing. The optimized and validated method can be used for the simultaneous determination of the five cold medicine ingredients in the tablets.
Phase gradient algorithm based on co-axis two-step phase-shifting interferometry and its application
NASA Astrophysics Data System (ADS)
Wang, Yawei; Zhu, Qiong; Xu, Yuanyuan; Xin, Zhiduo; Liu, Jingye
2017-12-01
A phase gradient method based on co-axis two-step phase-shifting interferometry, is used to reveal the detailed information of a specimen. In this method, the phase gradient distribution can only be obtained by calculating both the first-order derivative and the radial Hilbert transformation of the intensity difference between two phase-shifted interferograms. The feasibility and accuracy of this method were fully verified by the simulation results for a polystyrene sphere and a red blood cell. The empirical results demonstrated that phase gradient is sensitive to changes in the refractive index and morphology. Because phase retrieval and tedious phase unwrapping are not required, the calculation speed is faster. In addition, co-axis interferometry has high spatial resolution.
B1 transmit phase gradient coil for single-axis TRASE RF encoding.
Deng, Qunli; King, Scott B; Volotovskyy, Vyacheslav; Tomanek, Boguslaw; Sharp, Jonathan C
2013-07-01
TRASE (Transmit Array Spatial Encoding) MRI uses RF transmit phase gradients instead of B0 field gradients for k-space traversal and high-resolution MR image formation. Transmit coil performance is a key determinant of TRASE image quality. The purpose of this work is to design an optimized RF transmit phase gradient array for spatial encoding in a transverse direction (x- or y- axis) for a 0.2T vertical B0 field MRI system, using a single transmitter channel. This requires the generation of two transmit B1 RF fields with uniform amplitude and positive and negative linear phase gradients respectively over the imaging volume. A two-element array consisting of a double Maxwell-type coil and a Helmholtz-type coil was designed using 3D field simulations. The phase gradient polarity is set by the relative phase of the RF signals driving the simultaneously energized elements. Field mapping and 1D TRASE imaging experiments confirmed that the constructed coil produced the fields and operated as designed. A substantially larger imaging volume relative to that obtainable from a non-optimized Maxwell-Helmholtz design was achieved. The Maxwell (sine)-Helmholtz (cosine) approach has proven successful for a horizontal phase gradient coil. A similar approach may be useful for other phase-gradient coil designs. Copyright © 2013 Elsevier Inc. All rights reserved.
Ling, Yun; Zhao, Yun-feng; Li, Zhi-jun; Zhang, Gong; Wu, Yongning
2005-03-01
A high-performance liquid chromatography method was developed for the determination of total tea catechin and caffeine. The catechins needed to be determined are: (-)-catechin, (-)-epigallocatechin, (-)-epigallocatechin gallate, (-)-epicatechin, (-)-epicatechin gallate, (-)-gallocatechin, (-)-gallocatechin gallate, (-)-catechin gallate and caffeine. The catechins in the tea was extracted with water:ethanol (3:7) by sonication for 20 min. After the extraction solution was centrifuged, it was analyzed by HPLC. The column used was a CAPCELL PAK C18 MG (4.6mm I.D. x 150mm) and gradient elution at constant column temperature with 30 degrees C under UV detector with 210nm. Mobile phase A was 0.1% H3PO4 in water, mobile phase B was 0.1% H3PO4 in methanol with the flow rate 1ml/min. The results showed that the concentration of the catechins and caffeine and their peak areas achieved good linear relation, r > 0.999. The recoveries were between 61.7%-117.3%. RSD was below 10%. With this method, some tea samples were determined, the results were favorable. The method can be applied for determination of catechin and caffeine in tea and tea beverages.
Wiese, Steffen; Teutenberg, Thorsten; Schmidt, Torsten C
2012-01-27
In the present work it is shown that the linear elution strength (LES) model which was adapted from temperature-programming gas chromatography (GC) can also be employed for systematic method development in high-temperature liquid chromatography (HT-HPLC). The ability to predict isothermal retention times based on temperature-gradient as well as isothermal input data was investigated. For a small temperature interval of ΔT=40°C, both approaches result in very similar predictions. Average relative errors of predicted retention times of 2.7% and 1.9% were observed for simulations based on isothermal and temperature-gradient measurements, respectively. Concurrently, it was investigated whether the accuracy of retention time predictions of segmented temperature gradients can be further improved by temperature dependent calculation of the parameter S(T) of the LES relationship. It was found that the accuracy of retention time predictions of multi-step temperature gradients can be improved to around 1.5%, if S(T) was also calculated temperature dependent. The adjusted experimental design making use of four temperature-gradient measurements was applied for systematic method development of selected food additives by high-temperature liquid chromatography. Method development was performed within a temperature interval from 40°C to 180°C using water as mobile phase. Two separation methods were established where selected food additives were baseline separated. In addition, a good agreement between simulation and experiment was observed, because an average relative error of predicted retention times of complex segmented temperature gradients less than 5% was observed. Finally, a schedule of recommendations to assist the practitioner during systematic method development in high-temperature liquid chromatography was established. Copyright © 2011 Elsevier B.V. All rights reserved.
On axial temperature gradients due to large pressure drops in dense fluid chromatography.
Colgate, Sam O; Berger, Terry A
2015-03-13
The effect of energy degradation (Degradation is the creation of net entropy resulting from irreversibility.) accompanying pressure drops across chromatographic columns is examined with regard to explaining axial temperature gradients in both high performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC). The observed effects of warming and cooling can be explained equally well in the language of thermodynamics or fluid dynamics. The necessary equivalence of these treatments is reviewed here to show the legitimacy of using whichever one supports the simpler determination of features of interest. The determination of temperature profiles in columns by direct application of the laws of thermodynamics is somewhat simpler than applying them indirectly by solving the Navier-Stokes (NS) equations. Both disciplines show that the preferred strategy for minimizing the reduction in peak quality caused by temperature gradients is to operate columns as nearly adiabatically as possible (i.e. as Joule-Thomson expansions). This useful fact, however, is not widely familiar or appreciated in the chromatography community due to some misunderstanding of the meaning of certain terms and expressions used in these disciplines. In fluid dynamics, the terms "resistive heating" or "frictional heating" have been widely used as synonyms for the dissipation function, Φ, in the NS energy equation. These terms have been widely used by chromatographers as well, but often misinterpreted as due to friction between the mobile phase and the column packing, when in fact Φ describes the increase in entropy of the system (dissipation, ∫TdSuniv>0) due to the irreversible decompression of the mobile phase. Two distinctly different contributions to the irreversibility are identified; (1) ΔSext, viscous dissipation of work done by the external surroundings driving the flow (the pump) contributing to its warming, and (2) ΔSint, entropy change accompanying decompression of fluid in the column, contributing either to warming or cooling depending on local density and temperature. The molecular basis for this variation is described. Sample calculations of dissipation and temperature profiles of several model fluids including carbon dioxide-methanol mixtures are presented, based on the NIST REFPROP program including select equations of state and property calculation software. Copyright © 2015 Elsevier B.V. All rights reserved.
Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois A; Guiochon, Georges
2014-01-17
Five methods for controlling the mobile phase flow rate for gradient elution analyses using very high pressure liquid chromatography (VHPLC) were tested to determine thermal stability of the column during rapid gradient separations. To obtain rapid separations, instruments are operated at high flow rates and high inlet pressure leading to uneven thermal effects across columns and additional time needed to restore thermal equilibrium between successive analyses. The purpose of this study is to investigate means to minimize thermal instability and obtain reliable results by measuring the reproducibility of the results of six replicate gradient separations of a nine component RPLC standard mixture under various experimental conditions with no post-run times. Gradient separations under different conditions were performed: constant flow rates, two sets of constant pressure operation, programmed flow constant pressure operation, and conditions which theoretically should yield a constant net heat loss at the column's wall. The results show that using constant flow rates, programmed flow constant pressures, and constant heat loss at the column's wall all provide reproducible separations. However, performing separations using a high constant pressure with programmed flow reduces the analysis time by 16% compared to constant flow rate methods. For the constant flow rate, programmed flow constant pressure, and constant wall heat experiments no equilibration time (post-run time) was required to obtain highly reproducible data. Copyright © 2013 Elsevier B.V. All rights reserved.
Direct coupling of microbore HPLC columns to MS systems
NASA Technical Reports Server (NTRS)
Mcnair, H. M.
1985-01-01
A detailed investigation using electron microscopy was conducted which examined the conditions of materials used in the construction of stable, high performance microbore liquid chromatography (LC) columns. Small details proved to be important. The effects of temperature on the elution of several homologous series used as probe compounds was examined in reverse phase systems. They showed that accessible temperature changes provide roughly half the increase in solvent strength that would be obtained going from a 100% aqueous to a 100% organic mobile phase, which is sufficient to warrant their use in many analyses requiring the use of gradients. Air circulation temperature control systems provide the easiest means of obtaining rapid, wide range changes in column temperature. However, slow heat transfer from the gas leads to thermal nonuniformity in the column and a decrease in resolution as the temperature program progresses.
A generic multi-flex-body dynamics, controls simulation tool for space station
NASA Technical Reports Server (NTRS)
London, Ken W.; Lee, John F.; Singh, Ramen P.; Schubele, Buddy
1991-01-01
An order (n) multiflex body Space Station simulation tool is introduced. The flex multibody modeling is generic enough to model all phases of Space Station from build up through to Assembly Complete configuration and beyond. Multibody subsystems such as the Mobile Servicing System (MSS) undergoing a prescribed translation and rotation are also allowed. The software includes aerodynamic, gravity gradient, and magnetic field models. User defined controllers can be discrete or continuous. Extensive preprocessing of 'body by body' NASTRAN flex data is built in. A significant aspect, too, is the integrated controls design capability which includes model reduction and analytic linearization.
Density gradient electrophoresis of cultured human embryonic kidney cells
NASA Technical Reports Server (NTRS)
Plank, L. D.; Kunze, M. E.; Giranda, V.; Todd, P. W.
1985-01-01
Ground based confirmation of the electrophoretic heterogeneity of human embryonic kidney cell cultures, the general characterization of their electrophoretic migration, and observations on the general properties of cultures derived from electrophoretic subpopulations were studied. Cell migration in a density gradient electrophoresis column and cell electrophoretic mobility was determined. The mobility and heterogeneity of cultured human embryonic kidney cells with those of fixed rat erythrocytes as model test particle was compared. Electrophoretically separated cell subpopulations with respect to size, viability, and culture characteristics were examined.
RP-HPLC ANALYSIS OF ACIDIC AND BASIC DRUGS IN SYSTEMS WITH DIETHYLAMINE AS ELUENTS ADDITIVE.
Petruczynik, Anna; Wroblewski, Karol; Strozek, Szymon; Waksmundzka-Hajnos, Monika
2016-11-01
The chromatographic behavior of some basic and acidic drugs was studied on Cl 8, Phenyl-Hexyl and Polar RP columns with methanol or acetonitrile as organic modifiers of aqueous mobile phases containing addition of diethylamine. Diethylamine plays a double function of silanol blocker reagent in analysis of basic drugs and ion-pair reagent in analysis of acidic drugs. Most symmetrical peaks and highest system efficiency were obtained on Phenyl-Hexyl and Polar RP columns in tested mobile phase systems compared to results obtained on C18 column. A new rapid, simple, specific and accurate reverse phase liquid chromatographic method was developed for the simultaneous determination of atorvastatin - antihyperlipidemic drug and amlodipine - calcium channel blocker in one pharmaceutical formulation. Atorvastatin is an acidic compounds while amlodipine is a basic substance. The chromatographic separation was carried out on Phenyl-Hexyl column by gradient elution mode with acetonitrile as organic modifier, acetate buffer at pH 3.5 and Q.025 M/L diethylamine. The proposed method was validated for specificity, precision, accuracy, linearity, and robustness. The linearity range of atorvastatin and amlodipine for 5 - 100 μg/mL was obtained with limits of-detection (LOD) 3.2750 gg/mL and 3.2102 μg/mL, respectively. The proposed method made use of DAD as a tool for peak identity and purity confirmation.
Sreenivasulu, J; Venkata Ramana, P; Sampath Kumar Reddy, G; Nagaraju, Ch V S; Thirumalai Rajan, S; Eswaraiah, S
2015-10-01
A novel, rapid, specific and stability-indicating reverse-phase high-performance liquid chromatography method was developed for the quantitative determination of related compounds, obtained from two different synthetic routes and degradation products of Azilsartan kamedoxomil (AZL). The method was developed by using a YMC-Pack pro C18 (150 × 4.6 mm, 3 µm) column with a mobile phase containing a gradient mobile phase combination. The eluted compounds were measured at wavelength 220 nm. The developed method run time was 25 min, within which AZL and its eight impurities were well separated with minimum 3.0 resolution. The drug substance was subjected to stress conditions of hydrolysis (acid, base and water), oxidation, photolysis, sunlight, 75% relative humidity and thermal degradation as per International Conference on Harmonization (ICH) prescribed stress conditions to ascertain the stability-indicating power of the method. Significant degradation was observed during acid, base, peroxide, water hydrolysis and 75% relative humidity studies. The mass balance of AZL was close to 100% in all the stress condition. The developed method was validated as per the ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Supplemental optical specifications for imaging systems: parameters of phase gradient
NASA Astrophysics Data System (ADS)
Xuan, Bin; Li, Jun-Feng; Wang, Peng; Chen, Xiao-Ping; Song, Shu-Mei; Xie, Jing-Jiang
2009-12-01
Specifications of phase error, peak to valley (PV), and root mean square (rms) are not able to represent the properties of a wavefront reasonably because of their irresponsibility for spatial frequencies. Power spectral density is a parameter that is especially effective to indicate the frequency regime. However, it seems not convenient for opticians to implement. Parameters of phase gradient, PV gradient, and rms gradient are most correlated with a point-spread function of an imaging system, and they can provide clear instruction of manufacture. The algorithms of gradient parameters have been modified in order to represent the image quality better. In order to demonstrate the analyses, an experimental spherical mirror has been worked out. It is clear that imaging performances can be maintained while manufacture difficulties are decreased when a reasonable trade-off between specifications of phase error and phase gradient is made.
Occurrence of acidic PPCPs in surface and drinking waters by UHPLC-MS/MS
NASA Astrophysics Data System (ADS)
Picó, Yolanda; Carmona, Eric; Andreu, Vicente
2015-04-01
The term "emerging pollutants" stands for the substances that are released in the environment for which currently no regulations are established for their environmental monitoring. Their occurrence is reported worldwide in a range of aquatic environments, such as lakes, rivers, freshwater catchments, estuaries, reservoirs and marine waters. However, there are still few studies on their occurrence, levels and distribution in River Basins from Spain. This study is aimed at contributing information on the occurrence of three groups of emerging contaminants -licit and illicit drugs and personal care products- in the Turia River Basin. This River is a 280-km Mediterranean River with a flow rate 10.43 m3/s (Carmona et al., 2011), which is born in the province of Teruel and flows near the Valencia city. It has been selected because it is a typical Mediterranean River heavily affected by drought. The most 14 drank waters in Spain were analyzed to determinate the occurrence of some emerging pollutants. Selected contaminants include more than 40 pharmaceuticals, 5 personal care products and two illicit drugs. These substances were determined with an Agilent Technologies HPLC linked with a Triple Quad LC/MS in positive and negative ion mode using for compound separation a Waters C18 analytical column of 2.1x50mm and 3.5 µm particle diameter from Sunfire. The optimal mobile phase was a gradient of 5mM Ammonium fluoride in water (mobile phase A) and 5mM Ammonium fluoride in methanol (mobile phase B), at a flow rate of 0.2mL/min with a gradient that starts with 30% of mobile phase B and increase until 95% at minute 12 and remains 13 minutes more. The analytes were extracted from 250 mL of water by solid-phase extraction using Strata-X cartridges, eluted with methanol, evaporated and dissolved in 250 µL of methanol (Carmona et al. 2014). This procedure provides acceptable recoveries (>70%) and relative standard deviation (RSDs < 20%) at the limits of quantification, which are in the low ppb range ensuring sensitivity enough. Some of the studied compounds were detect at low amounts in the analysed water, which establish the real environmental occurrence of these potential contaminants. Further research will be devoted to characterize their sources and source pathways as well as to define and quantify processes that determine their transport and fate through the Turia River and to identify potential ecologic effects. Acknowledgment The Spanish Ministry of Economy and Competitiveness has supported this work through the projects SCARCE-CSD2009-00065, CGL2011-29703-C02-01 and CGL2011-29703-C02-02 References Carmona P., Ruiz J.M., Historical morphogenesis of the Turia River coastal flood plain in the Mediterranean littoral of Spain, CATENA, Volume 86, Issue 3, September 2011, Pages 139-149. Carmona, E., Andreu, V., Picó, Y., Occurrence of acidic pharmaceuticals and personal care products in Turia River Basin: from waste to drinking water. Science of the Total Environment (2014), vol. 484 pp. 53-63.
NASA Astrophysics Data System (ADS)
Köhler, Stephan J.; Lidman, Fredrik; Laudon, Hjalmar
2014-06-01
In this study we present data from a seven-year time series from 15 nested streams within a 68 km2 catchment, covering a pH gradient of almost three units. We demonstrate that the two landscape types, forest and wetlands, control the relative mobilization of Al and Fe in this boreal landscape. The La/U ratio is almost constant across the whole catchment despite large variations in pH, Al/Fe and TOC, whereas U and La mobilization increases with increasing contribution of deeper soils and groundwater further downstream. High Al/TOC ratios in the forested catchments suggest that Al originates from the underlying mineral soils, and low Al/TOC ratios derive from wetlands where Al is retained. We observe a competition effect on the binding to TOC between Al and La and also that the relationship between TOC, Al and La changes from the smaller (0.05-2 km2) catchments to larger (3-68 km2) downstream locations. As pH increase downstream, Al and Fe are gradually removed from the aqueous phase by precipitation of particulate gibbsite-like phases and ferrihydrite. This selective removal of Al and Fe from TOC binding sites results in higher La, and U concentrations downstream. Observed element patterns (U, La) and the range of upper continental crust normalized (La/Nd)UCC and (La/Yb)UCC in the near stream, riparian zone were very similar to the observed ratios across the whole catchment. The rising (La/Nd)UCC over (La/Yb)UCC may be due to a selective removal of REE binding to ferrihydrate in the riparian soil, the result of two distinctly different end-members but most probably not due to the in-stream precipitation of ferrihydrate or gibbsite-like phases.
Tietz, D; Gombocz, E; Chrambach, A
1991-10-01
This study presents a computerized evaluation of pore gradient gel electrophoretograms to arrive at estimates for both the particle-free mobility and retardation coefficient, which is related to particle size. Agarose pore gradient gels ranging from 0.2 to 1.1% agarose were formed. Gel gradients were stabilized during their formation by a density gradient of 0-20% 5-(N-2,3-dihydroxypropylacetamido)- 2,4,6-triiodo-N,N'bis-(2,3-dihydroxypropyl)-isophthalamide (Nycodenz). Densitometry of gelled-in Bromophenol Blue showed that these pore gradients exhibited a linear central segment and were reproducible. Migration distances of polystyrene sulfate microspheres (36.5 nm radius) in agarose pore gradient gel electrophoresis were determined by time-lapse photography at several durations of electrophoresis. These migration distances were evaluated as a function of migration time as previously reported (D. Tietz, Adv. Electrophoresis 1988, 2, 109-169). Although this is not necessarily required, the mathematical approach used in this study assumed linearity of both the pore gradient and the Ferguson plot for reasons of simplicity. The data evaluation on the basis of the extended Ogston model is incorporated in a user-friendly program, GRADFIT, which is designed for personal computers (Macintosh). The results obtained are compared with (1) conventional electrophoresis using several gels of single concentration with and without Nycodenz, and (ii) a different mathematical approach for the analysis of gradient gels (Rodbard et al., Anal. Biochem. 1971, 40, 135-157). Moreover, a simple procedure for evaluating linear pore gradient gels using linear regression analysis is presented. It is concluded that the values of particle-free mobility and retardation coefficient derived from pore gradient gel electrophoresis using the different mathematical methods are statistically indistinguishable from each other. However, these values are different, albeit close, to those obtained from conventional Ferguson plots. One of the possible reasons for this relatively minor discrepancy is that the particle-free mobility changed slightly during electrophoresis, which has a different effect on electrophoresis in homogeneous gels (single time measurement) and pore gradient gels (multiple time measurements). The characterization of particles according to size and charge by pore gradient electrophoresis provides a significant operational simplification and sample economy compared to that requiring the use of several gel concentrations, although at the price of increased requirements of instrumentation.
Amer, Sawsan M; Abbas, Samah S; Shehata, Mostafa A; Ali, Nahed M
2008-01-01
A simple and reliable high-performance liquid chromatographic method was developed for the simultaneous determination of mixture of phenylephrine hydrochloride (PHENYL), guaifenesin (GUAIF), and chlorpheniramine maleate (CHLO) either in pure form or in the presence of methylparaben and propylparaben in a commercial cough syrup dosage form. Separation was achieved on a C8 column using 0.005 M heptane sulfonic acid sodium salt (pH 3.4 +/- 0.1) and acetonitrile as a mobile phase by gradient elution at different flow rates, and detection was done spectrophotometrically at 210 nm. A linear relationship in the range of 30-180, 120-1800, and 10-60 microg/mL was obtained for PHENYL, GUAIF, and CHLO, respectively. The results were statistically analyzed and compared with those obtained by applying the British Pharmacopoeia (2002) method and showed that the proposed method is precise, accurate, and can be easily applied for the determination of the drugs under investigation in pure form and in cough syrup formulations.
Bishop, Michael Jason; Crow, Brian S; Kovalcik, Kasey D; George, Joe; Bralley, James A
2007-04-01
A rapid and accurate quantitative method was developed and validated for the analysis of four urinary organic acids with nitrogen containing functional groups, formiminoglutamic acid (FIGLU), pyroglutamic acid (PYRGLU), 5-hydroxyindoleacetic acid (5-HIAA), and 2-methylhippuric acid (2-METHIP) by liquid chromatography tandem mass spectrometry (LC/MS/MS). The chromatography was developed using a weak anion-exchange amino column that provided mixed-mode retention of the analytes. The elution gradient relied on changes in mobile phase pH over a concave gradient, without the use of counter-ions or concentrated salt buffers. A simple sample preparation was used, only requiring the dilution of urine prior to instrumental analysis. The method was validated based on linearity (r2>or=0.995), accuracy (85-115%), precision (C.V.<12%), sample preparation stability (
Pous, X; Ruíz, M J; Picó, Y; Font, G
2001-09-01
Imidacloprid, metalaxyl, myclobutanil, propham, and thiabendazole have been simultaneously determined in strawberries, oranges, potatoes, pears, and melons by matrix solid-phase dispersion (MSPD) followed by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) in positive-ion mode. The samples were homogenized with C8 bonded silica as MSPD sorbent, placed in a glass column, and eluted with dichloromethane. Chromatographic separation of the compounds was achieved on a reversed-phase LC column using a methanol-ammonium formate (50 mmol L(-1)) gradient as a mobile phase. Samples were screened by monitoring the protonated molecular ion at m/z 256 for imidacloprid, 280 for metalaxyl, 289 for myclobutanil, and 202 for thiabendazole, and the main fragment at m/z 138 for propham. Positive samples were confirmed by multiple-ion monitoring. The repeatability (<20%) and recovery (>57%) of the method were good, and limits of detection (<0.05 mg kg(-1)) were adequate.
Swietach, Pawel; Leem, Chae-Hun; Spitzer, Kenneth W; Vaughan-Jones, Richard D
2005-04-01
It is often assumed that pH(i) is spatially uniform within cells. A double-barreled microperfusion system was used to apply solutions of weak acid (acetic acid, CO(2)) or base (ammonia) to localized regions of an isolated ventricular myocyte (guinea pig). A stable, longitudinal pH(i) gradient (up to 1 pH(i) unit) was observed (using confocal imaging of SNARF-1 fluorescence). Changing the fractional exposure of the cell to weak acid/base altered the gradient, as did changing the concentration and type of weak acid/base applied. A diffusion-reaction computational model accurately simulated this behavior of pH(i). The model assumes that H(i)(+) movement occurs via diffusive shuttling on mobile buffers, with little free H(+) diffusion. The average diffusion constant for mobile buffer was estimated as 33 x 10(-7) cm(2)/s, consistent with an apparent H(i)(+) diffusion coefficient, D(H)(app), of 14.4 x 10(-7) cm(2)/s (at pH(i) 7.07), a value two orders of magnitude lower than for H(+) ions in water but similar to that estimated recently from local acid injection via a cell-attached glass micropipette. We conclude that, because H(i)(+) mobility is so low, an extracellular concentration gradient of permeant weak acid readily induces pH(i) nonuniformity. Similar concentration gradients for weak acid (e.g., CO(2)) occur across border zones during regional myocardial ischemia, raising the possibility of steep pH(i) gradients within the heart under some pathophysiological conditions.
Inugala, Ugandar Reddy; Pothuraju, Nageswara Rao; Vangala, Ranga Reddy
2013-01-01
This paper describes the development of a rapid, novel, stability-indicating gradient reversed-phase high-performance liquid chromatographic method and associated system suitability parameters for the analysis of naproxcinod in the presence of its related substances and degradents using a quality-by-design approach. All of the factors that affect the separation of naproxcinod and its impurities and their mutual interactions were investigated and robustness of the method was ensured. The method was developed using an Ascentis Express C8 150 × 4.6 mm, 2.7 µm column with a mobile phase containing a gradient mixture of two solvents. The eluted compounds were monitored at 230 nm, the run time was 20 min within which naproxcinod and its eight impurities were satisfactorily separated. Naproxcinod was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Naproxcinod was found to degrade significantly in acidic and basic conditions and to be stable in thermal, photolytic, oxidative and aqueous degradation conditions. The degradation products were satisfactorily resolved from the primary peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness.
Krishnaiah, Ch; Reddy, A Raghupathi; Kumar, Ramesh; Mukkanti, K
2010-11-02
A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of purity of Valsartan drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. The method was developed using Waters Aquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 225 nm, the run time was within 9.5 min, which Valsartan and its seven impurities were well separated. Valsartan was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Valsartan was found to degrade significantly in acid and oxidative stress conditions and stable in base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of Valsartan in pharmaceutical dosage forms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, R.L.; MacQueen, D.B.; Bader, K.E.
1997-12-31
Alkali Metal Thermoelectric Converters (AMTEC) are efficient direct energy conversion devices that depend on the use of highly conductive beta-alumina membranes for their operation. The key component of the AMTEC system is a highly conductive Na-{beta}{double_prime}-alumina solid electrolyte which conducts sodium ions from the high to low temperature zone, thereby generating electricity. AMTEC cells convert thermal to electrical energy by using heat to produce and maintain an alkali metal concentration gradient across the ion transporting BASE membrane. They have developed a method for producing pure phase Na-{beta}{double_prime}-alumina and K-{beta}{double_prime}-alumina powders from single phase nano-sized carboxylato-alumoxanes precursors. Sodium or potassium ionsmore » (the mobile ions) and either Mg{sup 2+} or Li{sup +} ions (which stabilize the {beta}{double_prime}-alumina structure) can be atomically dispersed into the carboxylato-alumoxane lattice at low (< 100 C) temperature. Calculation of the carboxylato-alumoxane precursors at 1,200--1,500 C produces pure phase {beta}{double_prime}-alumina powders.« less
Annular beam with segmented phase gradients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Shubo; Wu, Liang; Tao, Shaohua, E-mail: eshtao@csu.edu.cn
2016-08-15
An annular beam with a single uniform-intensity ring and multiple segments of phase gradients is proposed in this paper. Different from the conventional superposed vortices, such as the modulated optical vortices and the collinear superposition of multiple orbital angular momentum modes, the designed annular beam has a doughnut intensity distribution whose radius is independent of the phase distribution of the beam in the imaging plane. The phase distribution along the circumference of the doughnut beam can be segmented with different phase gradients. Similar to a vortex beam, the annular beam can also exert torques and rotate a trapped particle owingmore » to the orbital angular momentum of the beam. As the beam possesses different phase gradients, the rotation velocity of the trapped particle can be varied along the circumference. The simulation and experimental results show that an annular beam with three segments of different phase gradients can rotate particles with controlled velocities. The beam has potential applications in optical trapping and optical information processing.« less
Chen, Pei; Atkinson, Renata; Wolf, Wayne R
2009-01-01
The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.
Chen, Pei; Atkinson, Renata; Wolf, Wayne R.
2014-01-01
The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 µm, 250 × 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLD/MS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration. PMID:19485230
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yagnik, S.K.
1982-09-01
It has been proposed that high-level nuclear waste be disposed in a geologic repository. Natural-salt deposits, which are being considered for this purpose, contain a small volume fraction of water in the form of brine inclusions distributed throughout the salt. Radioactive-decay heating of the nuclear wastes will impose a temperature gradient on the surrounding salt which mobilizes the brine inclusions. Inclusions filled completely with brine migrate up the temperature gradient and eventually accumulate brine near the buried waste forms. The brine may slowly corrode or degrade the waste forms which is undesirable. In this work, thermal gradient migration of bothmore » all-liquid and gas-liquid inclusions was experimentally studied in synthetic single crystals of NaCl and KCl using a hot-stage attachment to an optical microscope which was capable of imposing temperature gradients and axial compressive loads on the crystals. The migration velocities of the inclusions were found to be dependent on temperature, temperature gradient, and inclusion shape and size. The velocities were also dictated by the interfacial mass transfer resistance at brine/solid interface. This interfacial resistance depends on the dislocation density in the crystal, which in turn, depends on the axial compressive loading of the crystal. At low axial loads, the dependence between the velocity and temperature gradient is non-linear.At high axial loads, however, the interfacial resistance is reduced and the migration velocity depends linearly on the temperature gradient. All-liquid inclusions filled with mixed brines were also studied. For gas-liquid inclusions, three different gas phases (helium, air and argon) were compared. Migration studies were also conducted on single crystallites of natural salt as well as in polycrystalline natural salt samples. The behavior of the inclusions at large angle grain boundaries was observed. 35 figures, 3 tables.« less
Glycolipid class profiling by packed-column subcritical fluid chromatography.
Deschamps, Frantz S; Lesellier, Eric; Bleton, Jean; Baillet, Arlette; Tchapla, Alain; Chaminade, Pierre
2004-06-18
The potential of packed-column subcritical fluid chromatography (SubFC) for the separation of lipid classes has been assessed in this study. Three polar stationary phases were checked: silica, diol, and poly(vinyl alcohol). Carbon dioxide (CO2) with methanol as modifier was used as mobile phase and detection performed by evaporative light scattering detection. The influence of methanol content, temperature, and pressure on the chromatographic behavior of sphingolipids and glycolipids were investigated. A complete separation of lipid classes from a crude wheat lipid extract was achieved using a modifier gradient from 10 to 40% methanol in carbon dioxide. Solute selectivity was improved using coupled silica and diol columns in series. Because the variation of eluotropic strength depending on the fluid density changes, a normalized separation factor product (NSP) was used to select the nature, the number and the order of the columns to reach the optimum glycolipid separation.
NASA Astrophysics Data System (ADS)
Rakitin, M. S.; Mirzoev, A. A.; Mirzaev, D. A.
2018-04-01
Mobile hydrogen, when dissolving in metals, redistributes due to the density gradients and elastic stresses, and enables destruction processes or phase transformations in local volumes of a solvent metal. It is rather important in solid state physics to investigate these interactions. The first-principle calculations performed in terms of the density functional theory, are used for thermodynamic simulation of the elastic stress effect on the energy of hydrogen dissolution in α-Fe crystal lattice. The paper presents investigations of the total energy of Fe-H system depending on the lattice parameter. As a result, the relation is obtained between the hydrogen dissolution energy and stress. A good agreement is shown between the existing data and simulation results. The extended equation is suggested for the chemical potential of hydrogen atom in iron within the local stress field. Two parameters affecting the hydrogen distribution are compared, namely local stress and phase transformations.
Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.
2012-01-01
An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136
Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B
2012-01-01
An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.
Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong
2011-10-01
The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.
Zhao, Yong-Gang; Chen, Xiao-Hong; Yao, Shan-Shan; Pan, Sheng-Dong; Li, Xiao-Ping; Jin, Mi-Cong
2012-01-01
A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in red wine. The effects of ion-suppressors, i.e., trifluoroacetic acid (TFA) and ammonium acetate (AmAc) on retention behavior of nine food additives in RP-HPLC separation were discussed in detail. The relationships between retention factors of solutes and volume percent of ion-suppressors in the mobile-phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, respectively. The results showed that the ion suppressors had not only an ion suppression effect, but also an organic modification effect on the acidic analytes. The baseline separation of nine food additives was completed by a gradient elution with acetonitrile-TFA(0.01%, v/v)-AmAc(2.5 mmol L(-1)) aqueous solution as the mobile phase. The recoveries were between 80.2 - 99.5% for all analytes with RSDs in the range of 1.5 - 8.9%. The linearities were in the range of 0.2 - 100.0 mg L(-1) with determination coefficients (r(2)) higher than 0.9991 for all analytes. The limits of quantification (LOQs) were between 0.53 - 0.99 mg L(-1). The applicability of the proposed method to detect and quantify food additives has been demonstrated in the analysis of 30 real samples.
NASA Astrophysics Data System (ADS)
Hsu, Shao-Yiu; Glantz, Roland; Hilpert, Markus
2011-11-01
The mobilization of residual oil blobs in porous media is of major interest to the petroleum industry. We studied the Jamin effect, which hampers the blob mobilization, experimentally in a pore doublet model and explain the Jamin effect through contact angle hysteresis. A liquid blob was trapped in one of the tubes of the pore doublet model and then subjected to different pressure gradients. We measured the contact angles (in 2D and 3D) as well as the mean curvatures of the blob. Due to gravity effects and hysteresis, the contact angles of the blob were initially (zero pressure gradient) non-uniform and exhibited a pronounced altitude dependence. As the pressure gradient was increased, the contact angles became more uniform and the altitude dependence of the contact angle decreased. At the same time, the mean curvature of the drainage interface increased, and the mean curvature of the imbibition interface decreased. The pressure drops across the pore model, which we inferred with our theory from the measured contact angles and mean curvatures, were in line with the directly measured pressure data. We not only show that a trapped blob can sustain a finite pressure gradient but also develop methods to measure the contact angles and mean curvatures in 3D.
BLIPPED (BLIpped Pure Phase EncoDing) high resolution MRI with low amplitude gradients
NASA Astrophysics Data System (ADS)
Xiao, Dan; Balcom, Bruce J.
2017-12-01
MRI image resolution is proportional to the maximum k-space value, i.e. the temporal integral of the magnetic field gradient. High resolution imaging usually requires high gradient amplitudes and/or long spatial encoding times. Special gradient hardware is often required for high amplitudes and fast switching. We propose a high resolution imaging sequence that employs low amplitude gradients. This method was inspired by the previously proposed PEPI (π Echo Planar Imaging) sequence, which replaced EPI gradient reversals with multiple RF refocusing pulses. It has been shown that when the refocusing RF pulse is of high quality, i.e. sufficiently close to 180°, the magnetization phase introduced by the spatial encoding magnetic field gradient can be preserved and transferred to the following echo signal without phase rewinding. This phase encoding scheme requires blipped gradients that are identical for each echo, with low and constant amplitude, providing opportunities for high resolution imaging. We now extend the sequence to 3D pure phase encoding with low amplitude gradients. The method is compared with the Hybrid-SESPI (Spin Echo Single Point Imaging) technique to demonstrate the advantages in terms of low gradient duty cycle, compensation of concomitant magnetic field effects and minimal echo spacing, which lead to superior image quality and high resolution. The 3D imaging method was then applied with a parallel plate resonator RF probe, achieving a nominal spatial resolution of 17 μm in one dimension in the 3D image, requiring a maximum gradient amplitude of only 5.8 Gauss/cm.
75 FR 6473 - Primary National Ambient Air Quality Standards for Nitrogen Dioxide
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... review, however, some areas could be classified as non-attainment. Certain States will be required to... sources of NO X emissions are on-road mobile sources, electricity generating units, and non-road mobile... tracking. 2. NO 2 Air Quality and Gradients Around Roadways On-road and non-road mobile sources account for...
Separation of antibody drug conjugate species by RPLC: A generic method development approach.
Fekete, Szabolcs; Molnár, Imre; Guillarme, Davy
2017-04-15
This study reports the use of modelling software for the successful method development of IgG1 cysteine conjugated antibody drug conjugate (ADC) in RPLC. The goal of such a method is to be able to calculate the average drug to antibody ratio (DAR) of and ADC product. A generic method development strategy was proposed including the optimization of mobile phase temperature, gradient profile and mobile phase ternary composition. For the first time, a 3D retention modelling was presented for large therapeutic protein. Based on a limited number of preliminary experiments, a fast and efficient separation of the DAR species of a commercial ADC sample, namely brentuximab vedotin, was achieved. The prediction offered by the retention model was found to be highly reliable, with an average error of retention time prediction always lower than 0.5% using a 2D or 3D retention models. For routine purpose, four to six initial experiments were required to build the 2D retention models, while 12 experiments were recommended to create the 3D model. At the end, RPLC can therefore be considered as a good method for estimating the average DAR of an ADC, based on the observed peak area ratios of RPLC chromatogram of the reduced ADC sample. Copyright © 2017 Elsevier B.V. All rights reserved.
Bennett, Raffeal; Olesik, Susan V
2017-04-01
Enhanced fluidity liquid chromatography using the hydrophilic interaction retention mechanism (EFLC-HILIC) is studied as an alternative separation mode for analyzing oligosaccharides and other sugars. These carbohydrates, which are important for the study of foods and biological systems, are difficult to comprehensively profile and either require a non-green, expensive solvent (i.e. acetonitrile) or derivatization of the analytes at the expense of time, sample loss, and loss of quantitative information. These difficulties arise from the diverse isomerism, mutarotation, and lack of a useable chromophore/fluorophore for spectroscopic detection. Enhanced fluidity liquid chromatography is an alternative separation method that involves the use of conventional polar solvents, such as methanol/water mixtures, as the primary mobile phase component and liquid carbon dioxide (CO 2 ) as the modifier in subcritical conditions. The addition of liquid CO 2 enhances diffusivity and decreases viscosity while maintaining mixture polarity, which typically results in reduced time of analysis and higher efficiency. This work illustrates an optimized EFLC-HILIC separation of a test mixture of oligosaccharides and simple sugars with a resolution greater than 1.3 and an analysis time decrease of over 35% compared to a conventional HPLC HILIC-mode analysis using acetonitrile/water mobile phases. Copyright © 2017 Elsevier B.V. All rights reserved.
Bashir, Mubasher A; Radke, Wolfgang
2007-09-07
The suitability of a retention model especially designed for polymers is investigated to describe and predict the chromatographic retention behavior of poly(methyl methacrylate)s as a function of mobile phase composition and gradient steepness. It is found that three simple yet rationally chosen chromatographic experiments suffice to extract the analyte specific model parameters necessary to calculate the retention volumes. This allows predicting accurate retention volumes based on a minimum number of initial experiments. Therefore, methods for polymer separations can be developed in relatively short time. The suitability of the virtual chromatography approach to predict the separation of polymer blend is demonstrated for the first time using a blend of different polyacrylates.
Development of a Transportable Gravity Gradiometer Based on Atom Interferometry
NASA Astrophysics Data System (ADS)
Yu, N.; Kohel, J. M.; Aveline, D. C.; Kellogg, J. R.; Thompson, R. J.; Maleki, L.
2007-12-01
JPL is developing a transportable gravity gradiometer based on light-pulse atom interferometers for NASA's Earth Science Technology Office's Instrument Incubator Program. The inertial sensors in this instrument employ a quantum interference measurement technique, analogous to the precise phase measurements in atomic clocks, which offers increased sensitivity and improved long-term stability over traditional mechanical devices. We report on the implementation of this technique in JPL's gravity gradiometer, and on the current performance of the mobile instrument. We also discuss the prospects for satellite-based gravity field mapping, including high-resolution monitoring of time-varying fields from a single satellite platform and multi-component measurements of the gravitational gradient tensor, using atom interferometer-based instruments.
[HPLC fingerprint of the antiarrhythmic fraction of Valeriana officinalis].
Duan, Xue-Yun; Gong, Zhan-Feng; Chen, Shu-He; Fang, Ying; Liu, Yan-Wen
2009-06-01
To establish HPLC fingerprints of the Antiarrhythmic fraction of Valeriana officinalis. Agilent C18 (250 mm x 4.6 mm, 5 microm) column was used and the acetonitrile-water was chosen as the mobile phase in a gradient mode. The column temperature was 380 degrees C and the detection wavelength was 218 nm. The detection time was 70 min, and the flow rate was 1.0 mL/ min. Fifteen characteristic peaks were indicated in HPLC fingerprints. The relative retention time and the ranges of relative areas of the common peaks were also determined. This method is simple and accurate with a good reproducibility and provides a reference standard for the quality control of Valeriana officinalis.
das Neves, José; Sarmento, Bruno; Amiji, Mansoor; Bahia, Maria Fernanda
2012-12-12
Dapivirine, a non-nucleoside reverse transcriptase inhibitor, is being currently used for the development of potential anti-HIV microbicide formulations and delivery systems. A new high-performance liquid chromatography (HPLC) method with UV detection was developed for the assay of this drug in different biological matrices, namely cell lysates, receptor media from permeability experiments and homogenates of mucosal tissues. The method used a reversed-phase C18 column with a mobile phase composed of trifluoroacetic acid solution (0.1%, v/v) and acetonitrile in a gradient mode. Injection volume was 50μL and the flow rate 1mL/min. The total run time was 12min and UV detection was performed at 290nm for dapivirine and the internal standard (IS) diphenylamine. A Box-Behnken experimental design was used to study different experimental variables of the method, namely the ratio of the mobile phase components and the gradient time, and their influence in responses such as the retention factor, tailing factor, and theoretical plates for dapivirine and the IS, as well as the peak resolution between both compounds. The optimized method was further validated and its usefulness assessed for in vitro and ex vivo experiments using dapivirine or dapivirine-loaded nanoparticles. The method showed to be selective, linear, accurate and precise in the range of 0.02-1.5μg/mL. Other chromatographic parameters, namely carry-over, lower limit of quantification (0.02μg/mL), limit of detection (0.006μg/mL), recovery (equal or higher than 90.7%), and sample stability at different storage conditions, were also determined and found adequate for the intended purposes. The method was successfully used for cell uptake assays and permeability studies across cell monolayers and pig genital mucosal tissues. Overall, the proposed method provides a simple, versatile and reliable way for studying the behavior of dapivirine in different biological matrices and assessing its potential as an anti-HIV microbicide drug. Copyright © 2012 Elsevier B.V. All rights reserved.
Determination of the electric field gradient in RbCaF3 near the phase transition
NASA Astrophysics Data System (ADS)
Hepp, M. A.; Man, P. P.; Trokiner, A.; Zanni, H.; Fraissard, J.
1992-12-01
The fluoroperovskite, RbCaF 3 undergoes a phase transition at 195.5K from a cubic to a tetragonal phase. The order parameter for this transition is directly related to the electric field gradient which arises in the tetragonal phase. In this work, we have used three NMR methods to measure the electric field gradient at the 87Rb site in a single crystal of RbCaF 3, very near this transition. These experiments are based on recent theoretical developments which allow the measurement of quadrupole parameters even for nuclei in a weak electric field gradient.
Fibigr, Jakub; Majorová, Michaela; Kočová Vlčková, Hana; Solich, Petr; Šatínský, Dalibor
2018-03-20
The presented work describes the development and validation of a rapid UHPLC-UV method using a fused core particle column with an RP-Amide stationary phase for the separation and quantitative analysis of caffeoylquinic and di-caffeoylquinic acids in green coffee extracts. Three caffeoylquinic acids (3-caffeoylquinic acid, 4-caffeoylquinic acid, and 5-caffeoylquinic acid) and two di-caffeoylquinic acids (1,3-di-caffeoylquinic acid, and 3,5-di-caffeoylquinic acid) were separated and analyzed in 8 min. That was possible due to the unique selectivity of the RP-Amide stationary phase for the analyzed acids. The retention behavior of all analytes under different compositions of the mobile phase on different columns was evaluated in this study. The optimal chromatographic separation was performed using an Ascentis Express RP-Amide (100 × 2.1 mm) fused-core column with a particle size of 2.7 μm at a temperature of 30 °C. For validation of the newly developed method, acetonitrile was used as mobile phase B and 5% formic acid, filtrated through a 0.22 μm filter, was used as mobile phase A. They were delivered at a flow rate of 0.9 mL min -1 according to the elution gradient program. The detection wavelength was set at 325 nm. A solid-liquid extraction with a solution of methanol and a 5% water solution of formic acid (25 + 75 v/v) using an ultrasonic bath was chosen for the preparation of the available commercial samples of food supplements containing a green coffee extract. Recoveries for all analyzed acids were 98.2-101.0% and the relative standard deviation ranged from 0.3% to 1.4% for intra-day and from 0.3% to 3.0% for inter-day repeatability. The limits of detection were in the range of 0.30-0.53 μg mL -1 . Copyright © 2018. Published by Elsevier B.V.
Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao
2013-01-01
A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. The buffer consisted of 0.01 M potassium dihydrogen phosphate with the pH adjusted to 8.0 by using diethylamine. In the developed HPLC method, the resolution between Tolperisone and its four potential impurities was found to be greater than 2.0. Regression analysis showed an R value (correlation coefficient) of greater than 0.999 for the Tolperisone impurities. This method was capable of detecting all four impurities of Tolperisone at a level of 0.19 μg/mL with respect to the test concentration of 1000 μg/mL for a 10 µl injection volume. The tablets were subjected to the stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in base hydrolysis, water hydrolysis, and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 100%. The established method was validated and found to be linear, accurate, precise, specific, robust, and rugged.
Moloney, M; Tuck, S; Ramkumar, A; Furey, A; Danaher, M
2018-03-01
A method was developed for the confirmatory and quantitative analysis of one pyrethrin and 18 pyrethroid residues in animal fat. Fat was extracted was collected from adipose tissue melted in an oven at 65 °C for 2 h. Fat samples (1 g) were dispersed with deactivated Florisil ® sorbent and extracted with MeCN. Sample extracts were purified by cold temperature precipitation at -30 °C for 4 h and further purified using dispersive solid-phase extraction (d-SPE) clean-up in tubes containing 500 mg of Z-SEP+ and 125 mg of PSA bonded silica. Purified samples were analysed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) detection. Chromatographic separation was carried out on a Acquity C 8 BEH column, using a binary gradient separation comprising of mobile phase A, 5 mM ammonium formate in water:MeOH (80:20, v/v,) and mobile phase B, 5 mM ammonium formate in MeOH. The mass spectrometer was operated in the positive electrospray ionisation mode (ESI(+)). Validation was performed following the 2002/657/EC guidelines. Trueness ranged between 84% and 143% and precision ranged between 3.9% and 29%. The developed method is particularly advantageous because the sample preparation procedure does not require complex sample extraction equipment and uses less solvent compared to other sample preparation protocols. Copyright © 2017 Elsevier B.V. All rights reserved.
Stanley, Shawn M R; Wee, Wei Khee; Lim, Boon Huat; Foo, Hsiao Ching
2007-04-01
Direct-injection LC-LC hybrid tandem MS methods have been developed for undertaking broad-based screening for acidic drugs in protein-precipitated plasma and neutral doping agents in equine urine. In both analyses, analytes present in the matrix were trapped using a HLB extraction column before being refocused and separated on a Chromolith RP-18e monolithic analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Each method has been optimised by the adoption of a mobile phase and gradient that was tailored to enhance ionisation in the MS source while maintaining good chromatographic behaviour for the majority of the target drugs. The analytical column eluent was fed into the heated nebulizer (HN) part of the Duospray interface attached to a 4000 QTRAP mass spectrometer. Information dependent acquisition (IDA) with dynamic background subtraction (DBS) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. Ninety-one percent of acidic drugs in protein-precipitated plasma and 80% of the neutral compounds in equine urine were detected when spiked at 10 ng/ml.
Rapid column heating method for subcritical water chromatography.
Fogwill, Michael O; Thurbide, Kevin B
2007-01-19
A novel resistive heating method is presented for subcritical water chromatography (SWC) that provides higher column heating rates than those conventionally obtained from temperature-programmed gas chromatography (GC) convection ovens. Since the polarity of water reduces dramatically with increasing temperature, SWC employs column heating to achieve gradient elution. As such, the rate at which the mobile phase is heated directly impacts the magnitude of such gradients applied in SWC. Data from the current study demonstrate that the maximum column heating rate attainable in a typical SWC apparatus (i.e. using a GC convection oven) is around 10 degrees C/min, even at instrument oven settings of over three times this value. Conversely, by wrapping the separation column with ceramic insulation and a resistively heated wire, the column heating rates are increased five-fold. As a result, elution times can be greatly decreased in SWC employing gradients. Separations of standard alcohol test mixtures demonstrate that the retention time of the latest eluting component decreases by 35 to 50% using the prototype method. Additionally, solute retention times in this mode deviate by less than 1% RSD over several trials, which compares very well to those obtained using a conventional GC convection oven. Results suggest that the developed method can be a useful alternative heating technique in SWC.
Analyzing chromatographic data using multilevel modeling.
Wiczling, Paweł
2018-06-01
It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.
Liang, Junling; Meng, Jie; Guo, Mengzhe; Yang, Zhi; Wu, Shihua
2013-05-03
Modern counter-current chromatography (CCC) originated from the helical coil planet centrifuge. Recently, spiral coils were found to possess higher separation efficiency in both the retention of stationary phase and solutes resolution than other CCC coils like the helical and toroidal coils used on type-J CCC and cross-axis CCC. In this work, we built a novel conical coil CCC for the preparative isolation and purification of tanshinones from Salvia miltiorrhiza Bunge. The conical coils were wound on three identical upright tapered holders in head-to-tail and left-handed direction and connected in series. Compared with helical and spiral coil CCC, conical coil CCC not only placed CCC column in a two-dimensional centrifugal field, but also provided a potential centrifugal force gradient both in axial and radial directions. The extra centrifugal gradient made mobile phase move faster and enabled CCC much higher retention of stationary phase and better resolution. As a result, higher efficiency has been obtained with the solvent system of hexane-ethyl acetate-methanol-water (HEMWat) with the volume ratio of 5:5:7:3 by using conical coil CCC apparatus. Four tanshinones, including cryptotanshinone (1), tanshinone I (2), 1,2-dihydrotanshinquinone (3) and tanshinone IIA (4), were well resolved from 500mg to 1g crude samples with high purity. Furthermore, the conical coil CCC can make a much higher solid phase retention, which makes it to be a powerful separation tool with high throughput. This is the first report about conical coil CCC for separation of tanshinones and it may also be an important advancement for natural products isolation. Copyright © 2013 Elsevier B.V. All rights reserved.
Patil, Nitin S; Mendhe, Rakesh B; Sankar, Ajeet A; Iyer, Harish
2008-01-11
In preparative chromatography, often the solubility of the sample in the mobile phase is limited, making the mobile phase unsuitable as a solvent for preparation of load. Generally, solvents that have high solubility for the sample also have higher elution strengths than the mobile phase. Additionally, at high loading volumes, these strong sample solvents are known to adversely affect the band profiles leading to poor chromatographic performance. Here, we show that controlling the mobile phase strength during loading and post-load elution resulted in improved band profiles when the sample solvent was stronger than the mobile phase. Such an approach improves performance in preparative chromatography by allowing either higher sample loading or higher organic content in mobile phase (without loss of yield). Alternately, the approach can be used for improvement in performance by increase in yield or product purity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... portable or mobile three-phase alternating current equipment; circuit breakers. 77.900 Section 77.900... mobile three-phase alternating current equipment; circuit breakers. Low- and medium-voltage circuits supplying power to portable or mobile three-phase alternating current equipment shall be protected by...
NASA Astrophysics Data System (ADS)
Koch, Boris P.; Dubinenkov, Ivan; Flerus, Ruth; Schmitt-Kopplin, Philippe; Kattner, Gerhard
2015-04-01
The impact of global warming on organic carbon budgets in permafrost systems are not well constrained. Changes in organic carbon fluxes caused by permafrost thaw depend on microbial activity, coastal erosion, mobilization of organic matter by increased porewater fluxes, and the inherent chemical stability of organic matter in permafrost soils. Here we aim at the identification and molecular characterization of active and inactive dissolved organic matter (DOM) components within the river-ocean transition. We studied four transects in the coastal Laptev Sea characterized by steep physico-chemical gradients. Molecular information on solid-phase extracted DOM was derived from ultrahigh resolution mass spectrometry. Changes of the chemical composition with salinity were used as a measure for DOM reactivity. Although changes of dissolved organic carbon (DOC) in the estuary suggested conservative mixing, only 27% of the identified molecular formulas behaved conservatively, 32% were moderately affected, and 41% were actively involved in estuarine processes. The molecular complexity in the DOM samples increased with growing marine influence and the average elemental composition (i.e. relative contribution of organic nitrogen and oxygen compounds) changed significantly with increasing salinity. These chemical changes were consistent with the results of a 20-day microbial incubation experiment, during which more than half of the permafrost-derived DOC was mineralized. We conclude that, although the DOC gradient in the estuary suggests conservative behavior, terrestrial DOM is substantially affected by estuarine processes which in turn also impact organic carbon budgets in the Lena Delta.
De Beer, Maarten; Lynen, Fréderic; Chen, Kai; Ferguson, Paul; Hanna-Brown, Melissa; Sandra, Pat
2010-03-01
Stationary-phase optimized selectivity liquid chromatography (SOS-LC) is a tool in reversed-phase LC (RP-LC) to optimize the selectivity for a given separation by combining stationary phases in a multisegment column. The presently (commercially) available SOS-LC optimization procedure and algorithm are only applicable to isocratic analyses. Step gradient SOS-LC has been developed, but this is still not very elegant for the analysis of complex mixtures composed of components covering a broad hydrophobicity range. A linear gradient prediction algorithm has been developed allowing one to apply SOS-LC as a generic RP-LC optimization method. The algorithm allows operation in isocratic, stepwise, and linear gradient run modes. The features of SOS-LC in the linear gradient mode are demonstrated by means of a mixture of 13 steroids, whereby baseline separation is predicted and experimentally demonstrated.
NASA Astrophysics Data System (ADS)
Brenner, Konstantin; Hennicker, Julian; Masson, Roland; Samier, Pierre
2018-03-01
In this work, we extend, to two-phase flow, the single-phase Darcy flow model proposed in [26], [12] in which the (d - 1)-dimensional flow in the fractures is coupled with the d-dimensional flow in the matrix. Three types of so called hybrid-dimensional two-phase Darcy flow models are proposed. They all account for fractures acting either as drains or as barriers, since they allow pressure jumps at the matrix-fracture interfaces. The models also permit to treat gravity dominated flow as well as discontinuous capillary pressure at the material interfaces. The three models differ by their transmission conditions at matrix fracture interfaces: while the first model accounts for the nonlinear two-phase Darcy flux conservations, the second and third ones are based on the linear single phase Darcy flux conservations combined with different approximations of the mobilities. We adapt the Vertex Approximate Gradient (VAG) scheme to this problem, in order to account for anisotropy and heterogeneity aspects as well as for applicability on general meshes. Several test cases are presented to compare our hybrid-dimensional models to the generic equi-dimensional model, in which fractures have the same dimension as the matrix, leading to deep insight about the quality of the proposed reduced models.
Lipid diffusion in alcoholic environment.
Rifici, Simona; Corsaro, Carmelo; Crupi, Cristina; Nibali, Valeria Conti; Branca, Caterina; D'Angelo, Giovanna; Wanderlingh, Ulderico
2014-08-07
We have studied the effects of a high concentration of butanol and octanol on the phase behavior and on the lateral mobility of 1,2-palmitoyl-sn-glycero-3-phosphocholine (DPPC) by means of differential scanning calorimetry and pulsed-gradient stimulated-echo (PGSTE) NMR spectroscopy. A lowering of the lipid transition from the gel to the liquid-crystalline state for the membrane-alcohol systems has been observed. NMR measurements reveal three distinct diffusions in the DPPC-alcohol systems, characterized by a high, intermediate, and slow diffusivity, ascribed to the water, the alcohol, and the lipid, respectively. The lipid diffusion process is promoted in the liquid phase while it is hindered in the interdigitated phase due to the presence of alcohols. Furthermore, in the interdigitated phase, lipid lateral diffusion coefficients show a slight temperature dependence. To the best of our knowledge, this is the first time that lateral diffusion coefficients on alcohol with so a long chain, and at low temperatures, are reported. By the Arrhenius plots of the temperature dependence of the diffusion coefficients, we have evaluated the apparent activation energy in both the liquid and in the interdigitated phase. The presence of alcohol increases this value in both phases. An explanation in terms of a free volume model that takes into account also for energy factors is proposed.
Prencipe, Francesco Pio; Bruni, Renato; Guerrini, Alessandra; Rossi, Damiano; Benvenuti, Stefania; Pellati, Federica
2014-02-01
A detailed investigation on the chemical composition and chemopreventive activity of Vaccinium floribundum Kunth berries was carried out in comparison with Vaccinium myrtillus L. Berry polyphenols were extracted by using two sequential dynamic maceration steps, which enabled to maximize the yields of secondary metabolites. In particular, phenolic acids and flavonols were extracted from berries using ethyl acetate (EtOAc), whereas anthocyanins were extracted from the residue with 0.6M HCl in methanol (MeOH). The analysis of secondary metabolites in berry extracts was performed by means of two specific HPLC methods. Phenolic acids and flavonols were analyzed on an Ascentis C18 column (250mm×4.6mm I.D., 5μm), with a gradient mobile phase composed of 0.1M HCOOH in H2O and ACN. Anthocyanin analysis was carried out on a Zorbax SB-C18 column (150mm×4.6mm I.D., 5μm), with a gradient mobile phase composed of H2O-HCOOH (9:1, v/v) and MeOH-H2O-HCOOH (5:4:1, v/v/v). Detection was performed by UV/DAD, MS and MS(2). The polyphenol composition of V. floribundum and V. myrtillus was studied in detail. The samples of V. floribundum analyzed in this study had a much higher content of both phenolic acids and flavonols in comparison with V. myrtillus (mean value 41.6±10.2 and 13.7±0.2mg/100g FW, respectively), while V. myrtillus showed a higher amount of anthocyanins if compared with V. floribundum (568.8±8.8 and mean value 376.2±49.9mg/100gFW, respectively). The extracts gave negative results in antimutagenic assays against carcinogens 2-amino-3,4-dimethylimidazo[4,5-f]quinoline (MeIQ) and 4-nitroquinoline-1-oxide (4-NQO), while they performed similarly in both ABTS(+) and DPPH antioxidant assays. Copyright © 2013 Elsevier B.V. All rights reserved.
Spacil, Zdenek; Folbrova, Jana; Megoulas, Nikolaos; Solich, Petr; Koupparis, Michael
2007-02-05
A novel method for the non-derivatization liquid chromatographic determination of metals (potassium, aluminium, calcium and magnesium) and organic compounds (ascorbate and aspartate) was developed and validated based on evaporative light scattering detection (ELSD). Separation of calcium, magnesium and aluminium was achieved by the cation exchange column Dionex CS-14 and an aqueous TFA mobile phase according to the following time program: 0-6 min TFA 0.96 mL L(-1), 6-7 min linear gradient from TFA 0.96-6.4 mL L(-1). Separation of potassium, magnesium and aspartate was achieved by the lipophilic C18 Waters Spherisorb column and isocratic aqueous 0.2 mL L(-1) TFA mobile phase. Separation of sodium, magnesium, ascorbate and citrate was also achieved by the C18 analytical column, according to the following elution program: 0-2.5 min aqueous nonafluoropentanoic acid (NFPA) 0.5 mL L(-1); 2.5-3.5 min linear gradient from 0.5 mL L(-1) NFPA to 1.0 mL L(-1) TFA. In all cases, evaporation temperature was 70 degrees C, pressure of the nebulizing gas (nitrogen) 3.5 bar, gain 11 and the flow rate 1.0 mL min(-1). Resolution among calcium and magnesium was 1.8, while for all other separations was > or = 3.2. Double logarithmic calibration curves were obtained within various ranges from 3-24 to 34-132 microg mL(-1), and with good correlation (r>0.996). Asymmetry factor ranged from 0.9 to 1.9 and limit of detection from 1.3 (magnesium) to 17 microg mL(-1) (ascorbate). The developed method was applied for the assay of potassium, magnesium, calcium, aluminium, aspartate and ascorbate in pharmaceuticals and food-supplements. The accuracy of the method was evaluated using spiked samples (%recovery 95-105%, %R.S.D. < 2) and the absence of constant or proportional errors was confirmed by dilution experiments.
[Content of indole alkaloids and bufadienolides contained in toad medicines].
Qu, Ting; Gao, Hui-Min; Chen, Liang-Mian; Wang, Zhi-Min; Zhang, Qi-Wei; Cheng, Yi-Yu
2012-10-01
To kinds of establish a HPLC method for determining contents of indole alkaloids and bufadienolides contained in toad medicines, and analyze two kinds of components contained in toad venom, toad skin and toad periostracum. As for alkaloids, Nucleosil C18 column was adopted with acetonitrile and water containing 0.5% potassium dihydrogen phosphate (6: 94, adjust pH to 3.2 with phosphate acid) as the mobile phase. The flow rate was 0.8 mL x min(-1), the detection wavelength was 275 nm, and the column temperature was 30 degrees C. As for bufadienolides, Alltima C18 column was adopted with acetonitrile and water containing 0.3% acetic acid (B) as the mobile phase. The gradient process was as follows: a linear gradient from 28% to 54% acetonitrile in the first 15 min, then kept at 54% for additional 20 min. The flow rate was 0.6 mL x min(-1), the detection wavelength was 296 nm, and the column temperature was 30 degrees C. The linear ranges were 0.079 6-0.796 microg for serotonin, 0.097 2-1.945 microg for N-methylserotonin, 0.074 4-0.744 microg for N,N-dimethylserotonin, 0.103-2.05 microg for N,N,N-trimethylserotonin, and 0.067 2-0.672 microg for bufothionine, respectively. The average recoveries of serotonin and N-methylserotonin were 98.6% and 91.3%, respectively. The linear ranges of gamabufotalin, bufotalin, bufalin, cinobufagin and resibufogenin were 0.004 83-0.614, 0.007 9-1.006, 0.007 95-1.016, 0.009 7-1.24 and 0.009 6-1.22 microg, respectively, and their average recoveries were 101.6%, 102.5%, 101.0%, 99.1% and 98.9%, respectively. Toad venom has the highest contents of indole alkaloids and bufadienolides, followed by toad skin, and toad periostracum showed the lowest contents and even no detection result.
NASA Astrophysics Data System (ADS)
Bruthans, Jiri; Svetlik, Daniel; Soukup, Jan; Schweigstillova, Jana; Valek, Jan; Sedlackova, Marketa; Mayo, Alan L.
2012-12-01
In Strelec Quarry, the Czech Republic, an underground conduit network > 300 m long with a volume of ~ 104 m3 and a catchment of 7 km2 developed over 5 years by groundwater flow in Cretaceous marine quartz sandstone. Similar landforms at natural exposures (conduits, slot canyons, undercuts) are stabilized by case hardening and have stopped evolving. The quarry offers a unique opportunity to study conduit evolution in sandstone at local to regional scales, from the initial stage to maturity, and to characterize the erosion processes which may form natural landforms prior to stabilization. A new technique was developed to distinguish erodible and non-erodible sandstone surfaces. Based on measurements of relative erodibility, drilling resistance, ambient and water-saturated tensile strength (TS) at natural and quarry exposures three distinct kinds of surfaces were found. 1) Erodible sandstone exposed at ~ 60% of surfaces in quarry. This sandstone loses as much as 99% of TS when saturated. 2) Sub-vertical fracture surfaces that are non-erodible already prior to exposure at ground surface and which keep considerable TS if saturated. 3) Case hardened surfaces that start to form after exposure. In favorable conditions they became non-erodible and reach the full TS in just 6 years. An increase in the hydraulic gradient from ~ 0.005 to > 0.02 triggered conduit evolution, based on long-term monitoring of water table in 18 wells and inflows to the quarry. Rapidly evolving major conduits are characterized by a channel gradient of ~ 0.01, a flow velocity ~ 40 cm/s and sediment concentration ~ 10 g/l. Flow in openings with a discharge 1 ml/s and hydraulic gradient > 0.05 exceeds the erosion threshold and initiates piping. In the first phase of conduit evolution, fast concentrated flow mobilizes erodible sandstone between sets of parallel fractures in the shallow phreatic zone. In the second phase the conduit opening mainly expands vertically upward into the vadose zone by mass wasting of undercut sandstone slabs. Mass wasting is responsible for > 90% of mobilized sandstone. Sides of the mature conduits are protected by non-erodible fracture surfaces. Natural landforms were probably formed very rapidly by overland flow, piping and possibly fluidization during or at the end of the glacial periods when sandstone was not yet protected by case hardening.
Middione, Matthew J; Thompson, Richard B; Ennis, Daniel B
2014-06-01
To investigate a novel phase-contrast MRI velocity-encoding technique for faster imaging and reduced chemical shift-induced phase errors. Velocity encoding with the slice select refocusing gradient achieves the target gradient moment by time shifting the refocusing gradient, which enables the use of the minimum in-phase echo time (TE) for faster imaging and reduced chemical shift-induced phase errors. Net forward flow was compared in 10 healthy subjects (N = 10) within the ascending aorta (aAo), main pulmonary artery (PA), and right/left pulmonary arteries (RPA/LPA) using conventional flow compensated and flow encoded (401 Hz/px and TE = 3.08 ms) and slice select refocused gradient velocity encoding (814 Hz/px and TE = 2.46 ms) at 3 T. Improved net forward flow agreement was measured across all vessels for slice select refocused gradient compared to flow compensated and flow encoded: aAo vs. PA (1.7% ± 1.9% vs. 5.8% ± 2.8%, P = 0.002), aAo vs. RPA + LPA (2.1% ± 1.7% vs. 6.0% ± 4.3%, P = 0.03), and PA vs. RPA + LPA (2.9% ± 2.1% vs. 6.1% ± 6.3%, P = 0.04), while increasing temporal resolution (35%) and signal-to-noise ratio (33%). Slice select refocused gradient phase-contrast MRI with a high receiver bandwidth and minimum in-phase TE provides more accurate and less variable flow measurements through the reduction of chemical shift-induced phase errors and a reduced TE/repetition time, which can be used to increase the temporal/spatial resolution and/or reduce breath hold durations. Copyright © 2013 Wiley Periodicals, Inc.
Isoelectric focusing of red blood cells in a density gradient stabilized column
NASA Technical Reports Server (NTRS)
Smolka, A. J. K.; Miller, T. Y.
1980-01-01
The effects of Ficoll and cell application pH on red blood cell electrophoretic mobility and focusing pH were investigated by focusing cells in a density gradient stabilized column. Sample loading, cell dispersion, column conductivity, resolution of separation, and the effect of Ampholines were examined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witte, K., E-mail: kerstin.witte@uni-rostock.de; Bodnar, W.; Schell, N.
A functional gradient material with eleven layers composed of a dental ceramics and titanium was successfully consolidated using field assisted sintering technique in a two-step sintering process. High energy X-ray diffraction studies on the gradient were performed at High Energy Material Science beamline at Desy in Hamburg. Phase composition, crystal unit edges and lattice mismatch along the gradient were determined applying Rietveld refinement procedure. Phase analysis revealed that the main crystalline phase present in the gradient is α-Ti. Crystallinity increases stepwisely along the gradient with a decreasing increment between every next layer, following rather the weight fraction of titanium. Themore » crystal unit edge a of titanium remains approximately constant with a value of 2.9686(1) Å, while c is reduced with increasing amount of titanium. In the layer with pure titanium the crystal unit edge c is constant with a value of 4.7174(2) Å. The lattice mismatch leading to an internal stress was calculated over the whole gradient. It was found that the maximal internal stress in titanium embedded in the studied gradient is significantly smaller than its yield strength, which implies that the structure of titanium along the whole gradient is mechanically stable. - Highlights: • High energy XRD studies of dental ceramics–Ti gradient material consolidated by FAST. • Phase composition, crystallinity and lattice parameters are determined. • Crystallinity increases stepwisely along the gradient following weight fraction of Ti. • Lattice mismatch leading to internal stress is calculated over the whole gradient. • Internal stress in α-Ti embedded in the gradient is smaller than its yield strength.« less
Li, Yongfeng; Ma, Hua; Wang, Jiafu; Pang, Yongqiang; Zheng, Qiqi; Chen, Hongya; Han, Yajuan; Zhang, Jieqiu; Qu, Shaobo
2017-01-01
A high-efficiency tri-band quasi-continuous phase gradient metamaterial is designed and demonstrated based on spoof surface plasmon polaritons (SSPPs). High-efficiency polarizaiton conversion transmission is firstly achieved via tailoring phase differece between the transmisive SSPP and the space wave in orthogonal directions. As an example, a tri-band circular-to-circular (CTC) polarization conversion metamateiral (PCM) was designed by a nonlinearly dispersive phase difference. Using such PCM unit cell, a tri-band quasi-continuous phase gradient metamaterial (PGM) was then realized by virtue of the Pancharatnam-Berry phase. The distribution of the cross-polarization transmission phase along the x-direction is continuous except for two infinitely small intervals near the phases 0° and 360°, and thus the phase gradient has definition at any point along the x-direction. The simulated normalized polarization conversion transmission spectrums together with the electric field distributions for circularly polarized wave and linearly polarized wave demonstrated the high-efficiency anomalous refraction of the quasi-continuous PGM. The experimental verification for the linearly polarized incidence was also provided. PMID:28079185
Simultaneous quantification of flavonoids and triterpenoids in licorice using HPLC.
Wang, Yuan-Chuen; Yang, Yi-Shan
2007-05-01
Numerous bioactive compounds are present in licorice (Glycyrrhizae Radix), including flavonoids and triterpenoids. In this study, a reversed-phase high-performance liquid chromatography (HPLC) method for simultaneous quantification of three flavonoids (liquiritin, liquiritigenin and isoliquiritigenin) and four triterpenoids (glycyrrhizin, 18alpha-glycyrrhetinic acid, 18beta-glycyrrhetinic acid and 18beta-glycyrrhetinic acid methyl ester) from licorice was developed, and further, to quantify these 7 compounds from 20 different licorice samples. Specifically, the reverse-phase HPLC was performed with a gradient mobile phase composed of 25 mM phosphate buffer (pH 2.5)-acetonitrile featuring gradient elution steps as follows: 0 min, 100:0; 10 min, 80:20; 50 min, 70:30; 73 min, 50:50; 110 min, 50:50; 125 min, 20:80; 140 min, 20:80, and peaks were detected at 254 nm. By using our technique, a rather good specificity was obtained regarding to the separation of these seven compounds. The regression coefficient for the linear equations for the seven compounds lay between 0.9978 and 0.9992. The limits of detection and quantification lay in the range of 0.044-0.084 and 0.13-0.25 microg/ml, respectively. The relative recovery rates for the seven compounds lay between 96.63+/-2.43 and 103.55+/-2.77%. Coefficient variation for intra-day and inter-day precisions lay in the range of 0.20-1.84 and 0.28-1.86%, respectively. Based upon our validation results, this analytical technique is a convenient method to simultaneous quantify numerous bioactive compounds derived from licorice, featuring good quantification parameters, accuracy and precision.
Călinescu, Octavian; Badea, Irinel A; Vlădescu, Luminiţa; Meltzer, Viorica; Pincu, Elena
2012-04-01
Determination of acetaminophen and its main impurities: 4-nitrophenol, 4'-chloroacetanilide, as well as 4-aminophenol and its degradation products, p-benzoquinone and hydroquinone has been developed and validated by a new high-performance liquid chromatography method. Chromatographic separation has been obtained on a Hypersil Duet C18/SCX column, using gradient elution, with a mixture of phosphate buffer (pH = 4.88) and methanol as a mobile phase. Analysis time did not exceed 14.5 min and good resolutions, peak shapes and asymmetries have resulted. The linearity of the method has been tested in the range of 5.0-60 µg/mL for acetaminophen and 0.5-6 µg/mL for the other compounds. The limits of detection and quantification have been also established to be lower than 0.1 µg/mL and 0.5 µg/mL, respectively. The method has been successfully applied for the analysis of commercial acetaminophen preparations. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Ares, Ana M; Valverde, Silvia; Bernal, José L; Toribio, Laura; Nozal, María J; Bernal, José
2017-10-01
In this study, a new method has been developed to determine flubendiamide in honey using liquid chromatography coupled to a selective mass spectrometry detector (quadrupole-time-of-flight). An efficient sample treatment involving a solid phase extraction with a C 18 sorbent was proposed (average analyte recoveries were between 94 and 104%). Chromatographic analysis (9min) was performed on a C 18 column (Gemini C 18 , 50×2.0mm, 3µm, 110Å). The mobile phase consisted of water and acetonitrile, with a flow rate of 0.5mL/min in gradient elution mode. The method was fully validated in terms of selectivity, limits of detection and quantification, matrix effect, linearity, trueness and precision. Low limits of detection and quantification were obtained, ranging from 0.1 to 0.2µg/kg and 0.4 to 0.6µg/kg, respectively. The method was applied to analyze flubendiamide in honey from different botanic origins (multifloral, rosemary and heather). Copyright © 2017 Elsevier Ltd. All rights reserved.
Bergh, Marianne Skov-Skov; Bogen, Inger Lise; Andersen, Jannike Mørch; Øiestad, Åse Marit Leere; Berg, Thomas
2018-01-01
A novel ion pair reversed phase ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of the stress hormones adrenaline, noradrenaline and corticosterone in rodent blood was developed and fully validated. Separations were performed on an Acquity HSS T3 column (2.1mm i.d.×100mm, 1.8μm) with gradient elution and a runtime of 5.5min. The retention of adrenaline and noradrenaline was substantially increased by employing the ion pair reagent heptafluorobutyric acid (HFBA). Ion pair reagents are usually added to the mobile phase only, but we demonstrate for the first time that including HFBA to the sample reconstitution solvent as well, has a major impact on the chromatography of these compounds. The stability of adrenaline and corticosterone in rodent blood was investigated using the surrogate analytes adrenaline-d 3 and corticosterone-d 8 . The applicability of the described method was demonstrated by measuring the concentration of stress hormones in rodent blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Semiconductor apparatus utilizing gradient freeze and liquid-solid techniques
NASA Technical Reports Server (NTRS)
Fleurial, Jean-Pierre (Inventor); Caillat, Thierry F. (Inventor); Borshchevsky, Alexander (Inventor)
1998-01-01
Transition metals of Group VIII (Co, Rh and Ir) have been prepared as semiconductor compounds with the general formula TSb.sub.3. The skutterudite-type crystal lattice structure of these semiconductor compounds and their enhanced thermoelectric properties results in semiconductor materials which may be used in the fabrication of thermoelectric elements to substantially improve the efficiency of the resulting thermoelectric device. Semiconductor materials having the desired skutterudite-type crystal lattice structure may be prepared in accordance with the present invention by using vertical gradient freezing techniques and/or liquid phase sintering techniques. Measurements of electrical and thermal transport properties of selected semiconductor materials prepared in accordance with the present invention, demonstrated high Hall mobilities (up to 1200 cm.sup.2.V.sup.-1.s.sup.-1) and good Seebeck coefficients (up to 150 .mu.VK.sup.-1 between 300.degree. C. and 700.degree. C.). Optimizing the transport properties of semiconductor materials prepared from elemental mixtures Co, Rh, Ir and Sb resulted in a substantial increase in the thermoelectric figure of merit (ZT) at temperatures as high as 400.degree. C. for thermoelectric elements fabricated from such semiconductor materials.
Kumar, Ashwini; Kumar Malik, Ashok; Kumar Tewary, Dhananjay; Singh, Baldev
2008-02-01
A simple and highly sensitive high pressure liquid chromatographic (HPLC-UV) method has been developed for the determination of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, in mobile phase citrate buffer (0.001 M) of pH 4.5 prepared in water (X), methanol (Y), and ACN (Z) using gradient at a flow rate of 1.0 mL/min by direct UV absorbance detection at lambda = 280 nm. Separation of analytes was studied on the C-18 and RP-amide columns and best results were observed on the RP-amide column with LODs (3.3 x S/m) 0.89, 0.55, 0.67, and 1.41 ng/mL for ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, respectively, and better RSD than the C-18 column. The recovery of Fluoroquinolones (FQs) in urine, ground water, hospital wastewater, and chicken muscle using this method is more than 90%. The method was successfully applied to the analysis of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid in urine, ground water, pharmaceutical dosage forms, hospital wastewater, and chicken muscle.
Ruschke, Stefan; Eggers, Holger; Kooijman, Hendrik; Diefenbach, Maximilian N; Baum, Thomas; Haase, Axel; Rummeny, Ernst J; Hu, Houchun H; Karampinos, Dimitrios C
2017-09-01
To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). A three-step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time-interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field-induced PDFF bias and the performance estimating the phase offset between time-interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. The simulation, phantom, and in vivo results showed in agreement with the theory an echo time-dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. Complex-based time-interleaved water-fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984-996, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
One Dimension Analytical Model of Normal Ballistic Impact on Ceramic/Metal Gradient Armor
NASA Astrophysics Data System (ADS)
Liu, Lisheng; Zhang, Qingjie; Zhai, Pengcheng; Cao, Dongfeng
2008-02-01
An analytical model of normal ballistic impact on the ceramic/metal gradient armor, which is based on modified Alekseevskii-Tate equations, has been developed. The process of gradient armour impacted by the long rod can be divided into four stages in this model. First stage is projectile's mass erosion or flowing phase, mushrooming phase and rigid phase; second one is the formation of comminuted ceramic conoid; third one is the penetration of gradient layer and last one is the penetration of metal back-up plate. The equations of third stage have been advanced by assuming the behavior of gradient layer as rigid-plastic and considering the effect of strain rate on the dynamic yield strength.
One Dimension Analytical Model of Normal Ballistic Impact on Ceramic/Metal Gradient Armor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu Lisheng; Zhang Qingjie; Zhai Pengcheng
2008-02-15
An analytical model of normal ballistic impact on the ceramic/metal gradient armor, which is based on modified Alekseevskii-Tate equations, has been developed. The process of gradient armour impacted by the long rod can be divided into four stages in this model. First stage is projectile's mass erosion or flowing phase, mushrooming phase and rigid phase; second one is the formation of comminuted ceramic conoid; third one is the penetration of gradient layer and last one is the penetration of metal back-up plate. The equations of third stage have been advanced by assuming the behavior of gradient layer as rigid-plastic andmore » considering the effect of strain rate on the dynamic yield strength.« less
Wu, Yi; Zhang, Xiaohui; Wei, Juan; Xue, Yunyun; Bahatibieke, Marjan; Wang, Yan; Yan, Chao
2009-09-01
Capillary electrochromatography (CEC), in which electroosmotic flow (EOF) created from the electrical double layer is made to act as a pump to drive the mobile phase in a capillary column packed with micro-particulates or coated with stationary phase. Both neutral and charged species can be resolved by CEC. It has been demonstrated that the efficiency of a separation obtained by electroosmotic propulsion is superior to that obtained by pressure-driven flow (as is the case in HPLC). CEC combines the best features of CE and versatile selectivity and large sample capacity of HPLC, promising high efficiency, high resolution, high selectivity and high peak capacity. However, in practice, when CEC is used without pressure, often used on a commercial CE instrument, there are problems and difficulties associated with bubbles formation and column dry-out. These difficulties can be overcome by a pressurized CEC (pCEC) system, in which a supplementary pressure is applied to the column in addition to the EOF. In such a system, a pressure can be applied to the capillary column to suppress bubbles formation. Quantitative sample introduction in pCEC can be easily achieved through a rotary-type injector. Most importantly, it is amenable for a solvent gradient mode, similar to that in HPLC, by programming the composition of mobile phase. The article brings a comprehensive survey of recent development of CEC and pCEC, including the development of instrumentation, capillary columns and stationary phase as well as CEC and pCEC applications in life science, biotechnology, pharmaceutical analysis, food safety and environmental security. Prospects for CEC and pCEC development and application are also discussed.
Chromatographic analysis of salicylic compounds in different species of the genus Salix.
Pobłocka-Olech, Loretta; van Nederkassel, Anne-Marie; Vander Heyden, Yvan; Krauze-Baranowska, Mirosława; Glód, Daniel; Baczek, Tomasz
2007-11-01
The separation of nine phenol glycosides--salicin, salicortin, 2'-acetylsalicortin, populin, tremulacin, salidroside, triandrin, picein and helicin--by normal phase (NP), reversed phase (RP) HPLC techniques and a coupling of NP and RP monolithic silica columns was studied. Among the above nine compounds only five--salicin, populin, tremulacin, salidroside and triandrin--were resolved in an NP system with a mobile phase comprising hexane/isopropanol/methanol (87:12:1, v/v/v). Optimized separation was performed with two coupled monolithic silica columns of different polarity (bare silica and RP-18). The method was applied to verify the presence of salicylic compounds and other phenolic derivatives in the bark of six species from the genus Salix, namely S. purpurea, S. daphnoides clone 1095, S. alba clone 1100, S. triandra, S. viminalis, and S. herbacea. Gradient elution with a mobile phase composed of acetonitrile and water containing 0.05% of trifluoroacetic acid, with increasing acetonitrile concentration from 3% to 48%, was chosen as optimal. For the selective detection of the salicylic compounds, an evaporative light scattering detector was employed along with a UV detector. The differences in the composition of phenols in the different plant materials were confirmed. Additionally, it must be emphasized that for the first time the presence of 2'-acetylsalicortin was revealed in S. alba clone 1100. Furthermore, an SPE-HPLC method was developed for the rapid analysis of the salicin content, analyzed as free and total fraction, in willow barks. The determined concentrations of total salicin varied from 25.4 mg/g in S. alba clone 1100 to 96.47 mg/g in S. daphnoides clone 1095.
Wang, Jiang; Pavurala, Naresh; Xu, Xiaoming; Krishnaiah, Yellela S R; Faustino, Patrick J
2018-05-04
To evaluate the bioavailability and pharmacokinetic profiles of two novel galantamine formulations as medical countermeasure products, an ultra-performance liquid chromatography-single quadrupole mass spectrometry (UPLC-MS) method was developed and validated for quantifying galantamine in guinea pig plasma using solid-phase extraction with a mixed mode strong cation exchange reversed-phase cartridge. Chromatographic separation was achieved on a Waters Acquity UPLC BEH C 18 column maintained at 40°C. The mobile phases were solution A, acetonitrile-water, 5:95 (v/v) and solution B, acetonitrile-water 90:10 (v/v), both containing 2 mM ammonium formate and 0.2% formic acid. The mobile phase was delivered utilizing a 3 min gradient program start with 95%A-5%B at a flow rate of 0.6 mL/min. The analyte and internal standard, galantamine-d3, were detected by selected ion monitoring mode on a Waters 3100 single quadrupole mass spectrometer with positive electrospray ionization. The method was validated according to the US Food and Drug Administration bioanalytical guidance. The method was selective and was linear over the analytical range of 2-2000 ng/mL. Accuracy and precision were acceptable with intra- and inter-day accuracies between 96.8 and 101% and precisions (RSD) <4.88%. The method was successfully implemented to measure galantamine plasma levels in a series of pre-clinical bioavailability studies for the evaluation of novel galantamine formulations. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Kline, David; Ritruthai, Vicha; Babajanian, Silva; Gao, Quanyin; Ingle, Prashant; Chang, Peter; Swanson, Gary
2017-05-01
A single-laboratory validation study is described for a method of quantitative analysis of aloins (aloins A and B) and aloe-emodin in aloe vera raw materials and finished products. This method used HPLC coupled with UV detection at 380 nm for the aloins and 430 nm for aloe-emodin. The advantage of this test method is that the target analytes are concentrated from the sample matrix (either liquid or solid form) using stepwise liquid-liquid extraction (water-ethyl acetate-methanol), followed by solvent evaporation and reconstitution. This sample preparation process is suitable for different forms of products. The concentrating step for aloins and aloe-emodin has enhanced the method quantitation level to 20 parts per billion (ppb). Reversed-phase chromatography using a 250 × 4.6 mm column under gradient elution conditions was used. Mobile phase A is 0.1% acetic acid in water and mobile phase B is 0.1% acetic acid in acetonitrile. The HPLC run starts with a 20% mobile phase B that reaches 35% at 13 min. From 13 to 30 min, mobile phase B is increased from 35 to 100%. From 30 to 40 min, mobile phase B is changed from 100% back to the initial condition of 20% for re-equilibration. The flow rate is 1 mL/min, with a 100 μL injection volume. Baseline separation (Rs > 2.0) for aloins A and B and aloe-emodin was observed under this chromatographic condition. This test method was validated with raw materials of aloe vera 5× (liquid) and aloe vera 200× (powder) and finished products of aloe concentrate (liquid) and aloe (powder). The linearity of the method was studied from 10 to 500 ppb for aloins A and B and aloe-emodin, with correlation coefficients of 0.999964, 0.999957, and 0.999980, respectively. The test method was proven to be specific, precise, accurate, rugged, and suitable for the intended quantitative analysis of aloins and aloe-emodin in raw materials and finished products. The S/N for aloins A and B and aloe-emodin at 10 ppb level were 12, 10, and 8, respectively, indicating our conservative LOD level at 10 ppb (the typical LOD level S/N is about 3). The S/N for aloins A and B and aloe-emodin at the 20 ppb level were 17, 14, and 16, respectively, indicating our conservative LOQ level at 20 ppb (the typical LOQ level S/N is about 10). The stock standard solution of a mixture of aloins and aloe-emodin and a working standard solution were found to be stable for at least 19 days when stored refrigerated at 2-8°C, with a recovery of 100 ± 5%.
Observations of wave-induced pore pressure gradients and bed level response on a surf zone sandbar
NASA Astrophysics Data System (ADS)
Anderson, Dylan; Cox, Dan; Mieras, Ryan; Puleo, Jack A.; Hsu, Tian-Jian
2017-06-01
Horizontal and vertical pressure gradients may be important physical mechanisms contributing to onshore sediment transport beneath steep, near-breaking waves in the surf zone. A barred beach was constructed in a large-scale laboratory wave flume with a fixed profile containing a mobile sediment layer on the crest of the sandbar. Horizontal and vertical pore pressure gradients were obtained by finite differences of measurements from an array of pressure transducers buried within the upper several centimeters of the bed. Colocated observations of erosion depth were made during asymmetric wave trials with wave heights between 0.10 and 0.98 m, consistently resulting in onshore sheet flow sediment transport. The pore pressure gradient vector within the bed exhibited temporal rotations during each wave cycle, directed predominantly upward under the trough and then rapidly rotating onshore and downward as the wavefront passed. The magnitude of the pore pressure gradient during each phase of rotation was correlated with local wave steepness and relative depth. Momentary bed failures as deep as 20 grain diameters were coincident with sharp increases in the onshore-directed pore pressure gradients, but occurred at horizontal pressure gradients less than theoretical critical values for initiation of the motion for compact beds. An expression combining the effects of both horizontal and vertical pore pressure gradients with bed shear stress and soil stability is used to determine that failure of the bed is initiated at nonnegligible values of both forces.
Extraction and identification of flavonoids from parsley extracts by HPLC analysis
NASA Astrophysics Data System (ADS)
Stan, M.; Soran, M. L.; Varodi, C.; Lung, I.
2012-02-01
Flavonoids are phenolic compounds isolated from a wide variety of plants, and are valuable for their multiple properties, including antioxidant and antimicrobial activities. In the present work, parsley (Petroselinum crispum L.) extracts were obtained by three different extraction techniques: maceration, ultrasonic-assisted and microwave-assisted solvent extractions. The extractions were performed with ethanol-water mixtures in various ratios. From these extracts, flavonoids like the flavones apigenin and luteolin, and the flavonols quercetin and kaempferol were identified using an HPLC Shimadzu apparatus equipped with PDA and MS detectors. The separation method involved a gradient step. The mobile phase consisted of two solvents: acetonitrile and distilled water with 0.1% formic acid. The separation was performed on a RP-C18 column.
NASA Astrophysics Data System (ADS)
Salikin, Jamilah; Abdullah, Aminah
2013-11-01
A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.
Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O
2010-02-01
The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.
Sinha, Arun Kumar; Verma, Subash Chandra; Sharma, Upendra Kumar
2007-01-01
A simple and fast method was developed using RP-HPLC for separation and quantitative determination of vanillin and related phenolic compounds in ethanolic extract of pods of Vanilla planifolia. Ten phenolic compounds, namely 4-hydroxybenzyl alcohol, vanillyl alcohol, 3,4-dihydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid, 4-hydroxybenzaldehyde, vanillin, p-coumaric acid, ferulic acid, and piperonal were quantitatively determined using ACN, methanol, and 0.2% acetic acid in water as a mobile phase with a gradient elution mode. The method showed good linearity, high precision, and good recovery of compounds of interest. The present method would be useful for analytical research and for routine analysis of vanilla extracts for their quality control.
Predicting ESI/MS Signal Change for Anions in Different Solvents.
Kruve, Anneli; Kaupmees, Karl
2017-05-02
LC/ESI/MS is a technique widely used for qualitative and quantitative analysis in various fields. However, quantification is currently possible only for compounds for which the standard substances are available, as the ionization efficiency of different compounds in ESI source differs by orders of magnitude. In this paper we present an approach for quantitative LC/ESI/MS analysis without standard substances. This approach relies on accurately predicting the ionization efficiencies in ESI source based on a model, which uses physicochemical parameters of analytes. Furthermore, the model has been made transferable between different mobile phases and instrument setups by using a suitable set of calibration compounds. This approach has been validated both in flow injection and chromatographic mode with gradient elution.
Miller, N T; Feibush, B; Karger, B L
1984-12-21
This paper examines the use of wide-pore silica-based hydrophilic ether-bonded phases for the chromatographic separation of proteins under mild elution conditions. In particular, ether phases of the following structure identical to Si-(CH2)3-O-(CH2-CH2-O)n-R, where n = 1, 2, 3 and R = methyl, ethyl or n-butyl, have been prepared. These phases can be employed either in high-performance hydrophobic-interaction or size-exclusion chromatography, depending on mobile phase conditions. In the hydrophobic-interaction mode, a gradient of decreasing salt concentration, e.g., from 3 M ammonium sulfate (pH 6.0, 25 degrees C), yields sharp peaks with high mass recovery of active proteins. In this mode, retention can be controlled by salt type and concentration, as well as by column temperature. In the size-exclusion mode, use of medium ionic strength, e.g., 0.5 M ammonium acetate (pH 6.0) yields linear calibration of log (MW[eta]) vs. retention volume. Even at 0.05 M salt concentration, no stationary phase charge effects on protein elution are observed. These bonded-phase columns exhibit good column-to-column reproducibility and constant retention for at least five months of continual use. Examples of the high-performance separation of proteins in both modes are illustrated.
Eom, Han Young; Park, So-Young; Kim, Min Kyung; Suh, Joon Hyuk; Yeom, Hyesun; Min, Jung Won; Kim, Unyong; Lee, Jeongmi; Youm, Jeong-Rok; Han, Sang Beom
2010-06-25
Saikosaponins are triterpene saponins derived from the roots of Bupleurum falcatum L. (Umbelliferae), which has been traditionally used to treat fever, inflammation, liver diseases, and nephritis. It is difficult to analyze saikosaponins using HPLC-UV due to the lack of chromophores. Therefore, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) method has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we compared CAD and ELSD methods in the simultaneous analysis of 10 saikosaponins, including saikosaponins-A, -B(1), -B(2), -B(3), -B(4), -C, -D, -G, -H and -I. A mixture of the 10 saikosaponins was injected into the Ascentis Express C18 column (100 mm x 4.6 mm, 2.7 microm) with gradient elution and detection with CAD and ELSD by splitting. We examined various factors that could affect the sensitivity of the detectors including various concentrations of additives, pH and flow rate of the mobile phase, purity of nitrogen gas and the CAD range. The sensitivity was determined based on the signal-to-noise ratio. The best sensitivity for CAD was achieved with 0.1 mM ammonium acetate at pH 4.0 in the mobile phase with a flow rate of 1.0 mL/min, and the CAD range at 100 pA, whereas that for ELSD was achieved with 0.01% acetic acid in the mobile phase with a flow rate at 0.8 mL/min. The purity of the nitrogen gas had only minor effects on the sensitivities of both detectors. Finally, the sensitivity for CAD was two to six times better than that of ELSD. Taken together, these results suggest that CAD provides a more sensitive analysis of the 10 saikosaponins than does ELSD. Copyright 2010 Elsevier B.V. All rights reserved.
Detection of ferromagnetic target based on mobile magnetic gradient tensor system
NASA Astrophysics Data System (ADS)
Gang, Y. I. N.; Yingtang, Zhang; Zhining, Li; Hongbo, Fan; Guoquan, Ren
2016-03-01
Attitude change of mobile magnetic gradient tensor system critically affects the precision of gradient measurements, thereby increasing ambiguity in target detection. This paper presents a rotational invariant-based method for locating and identifying ferromagnetic targets. Firstly, unit magnetic moment vector was derived based on the geometrical invariant, such that the intermediate eigenvector of the magnetic gradient tensor is perpendicular to the magnetic moment vector and the source-sensor displacement vector. Secondly, unit source-sensor displacement vector was derived based on the characteristic that the angle between magnetic moment vector and source-sensor displacement is a rotational invariant. By introducing a displacement vector between two measurement points, the magnetic moment vector and the source-sensor displacement vector were theoretically derived. To resolve the problem of measurement noises existing in the realistic detection applications, linear equations were formulated using invariants corresponding to several distinct measurement points and least square solution of magnetic moment vector and source-sensor displacement vector were obtained. Results of simulation and principal verification experiment showed the correctness of the analytical method, along with the practicability of the least square method.
First gas-phase metallicity gradients of 0.1 ≲ z ≲ 0.8 galaxies with MUSE
NASA Astrophysics Data System (ADS)
Carton, David; Brinchmann, Jarle; Contini, Thierry; Epinat, Benoît; Finley, Hayley; Richard, Johan; Patrício, Vera; Schaye, Joop; Nanayakkara, Themiya; Weilbacher, Peter M.; Wisotzki, Lutz
2018-05-01
Galaxies at low-redshift typically possess negative gas-phase metallicity gradients (centres more metal-rich than their outskirts). Whereas, it is not uncommon to observe positive metallicity gradients in higher-redshift galaxies (z ≳ 0.6). Bridging these epochs, we present gas-phase metallicity gradients of 84 star-forming galaxies between 0.08 < z < 0.84. Using the galaxies with reliably determined metallicity gradients, we measure the median metallicity gradient to be negative (-0.039^{+0.007}_{-0.009} dex/kpc). Underlying this, however, is significant scatter: (8 ± 3)% [7] of galaxies have significantly positive metallicity gradients, (38 ± 5)% [32] have significantly negative gradients, (31 ± 5)% [26] have gradients consistent with being flat. (The remaining (23 ± 5)% [19] have unreliable gradient estimates.) We notice a slight trend for a more negative metallicity gradient with both increasing stellar mass and increasing star formation rate (SFR). However, given the potential redshift and size selection effects, we do not consider these trends to be significant. Indeed, once we normalize the SFR relative to that of the main sequence, we do not observe any trend between the metallicity gradient and the normalized SFR. This is contrary to recent studies of galaxies at similar and higher redshifts. We do, however, identify a novel trend between the metallicity gradient of a galaxy and its size. Small galaxies (rd < 3 kpc) present a large spread in observed metallicity gradients (both negative and positive gradients). In contrast, we find no large galaxies (rd > 3 kpc) with positive metallicity gradients, and overall there is less scatter in the metallicity gradient amongst the large galaxies. These large (well-evolved) galaxies may be analogues of present-day galaxies, which also show a common negative metallicity gradient.
Semanjski, Ivana; Gautama, Sidharta
2015-07-03
Mobility management represents one of the most important parts of the smart city concept. The way we travel, at what time of the day, for what purposes and with what transportation modes, have a pertinent impact on the overall quality of life in cities. To manage this process, detailed and comprehensive information on individuals' behaviour is needed as well as effective feedback/communication channels. In this article, we explore the applicability of crowdsourced data for this purpose. We apply a gradient boosting trees algorithm to model individuals' mobility decision making processes (particularly concerning what transportation mode they are likely to use). To accomplish this we rely on data collected from three sources: a dedicated smartphone application, a geographic information systems-based web interface and weather forecast data collected over a period of six months. The applicability of the developed model is seen as a potential platform for personalized mobility management in smart cities and a communication tool between the city (to steer the users towards more sustainable behaviour by additionally weighting preferred suggestions) and users (who can give feedback on the acceptability of the provided suggestions, by accepting or rejecting them, providing an additional input to the learning process).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brand, H.; Doerfle, M.
1981-02-01
We present the gradient free energy in the BCS approximation for the A phase in high magnetic fields and the A/sub 1/ phase. The A phase without external magnetic field, which has been considered previously by Blount and Cross, emerges as a special case of the result for the A phase in high magnetic fields.
Ji, Chao; Feng, Feng; Chen, Zhengxing; Sun, Li; Chu, Xiaogang
2010-08-01
A high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS) method for the determination of five synthetic sweeteners (acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame) in wines has been developed. The HPLC separation was carried out on an Ultimate C18 column (100 mm x 2.1 mm, 3 microm). Several parameters, including the composition and pH of the mobile phase, column temperature and the monitor ions, were optimized for improving the chromatographic performance and the sensitivity of determination. The results demonstrated that the separation can be completed in less than 5 min by gradient elution with 20 mmol/L ammonium formate and 0.1% (v/v) formic acid (pH 3.8) and methanol as the mobile phase. The column temperature was kept at 45 degrees C. When the analytes were detected by ESI -MS/MS under multiple reaction monitoring mode, the detection limits were 0.6, 5, 1, 0.8 and 0.2 microg/L for acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame, respectively. The average recoveries ranged from 87.2% to 103%. The relative standard deviations were not more than 1.2%. This method is rapid, accurate, highly sensitive and suitable for the quality control of low concentration of the synthetic sweeteners, which are illegally added to wines and other foods with complex matrices.
Joo, Kyung-Mi; Han, Ji Yeon; Son, Eui Dong; Nam, Gae-Won; Chung, Han Young; Jeong, Hye-Jin; Cho, Jun-Cheol; Lim, Kyung-Min
2012-05-15
A rapid, sensitive and specific hydrophilic interaction liquid chromatography coupled to tandem mass spectrometric (HILIC-MS/MS) method for the simultaneous determination of pyroglutamic acid, cis- and trans-urocanic acid in human skin stratum corneum (SC) were developed and validated. This method was carried out without derivatization or addition of ion-pair additives in mobile phase. The analytes were extracted by PBS buffer solution and analyzed using an electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. Chromatographic separation was performed on an AQUITY UPLC amide column using gradient elution with the mobile phase of water and acetonitrile. The standard curves were linear over the concentration range of 1.0-250 ng/mL with a correlation coefficient higher than 0.999 with an LLOQ of 0.5 ng/mL. The lower limits of detection (LLOD) of these analytes were lower than 0.2 ng/mL. The intra- and inter-day precisions were measured to be below 7.7% and accuracies were within the range of 94.3-102.6%. The validated method was successfully applied to determine the level of pyroglutamic acid and cis-/trans-urocanic acid in the SC samples from forearm and forehead region of 19 human volunteers. Copyright © 2012 Elsevier B.V. All rights reserved.
Hargiss, Leonard O; Zipp, G Greg; Jessop, Theodore C; Sun, Xuejun; Keyes, Philip; Rawlins, David B; Liang, Zhi; Park, Kum Joo; Gu, Huizhong
2014-11-15
An ultra high-pressure liquid chromatography/mass spectrometry (UHPLC/MS) separation and analysis method has been devised for open access analysis of synthetic reactions used in the production of DNA-encoded chemical libraries. The aqueous mobile phase is 100mM hexafluoroisopropanol and 8.6mM triethylamine; the organic mobile phase is methanol. The UHPLC separation uses a C18 OST column (50mm×2.1mm×1.7μm) at 60°C, with a flow rate of 0.6mL/min. Gradient concentration is from 10 to 40% B in 1.0min, increasing to 95% B at 1.2min. Cycle time was about 5min. This method provides a detection limit of a 20-mer oligonucleotide by mass spectrometry of better than 1pmol on-column. Linear UV response for 20-mer extends from 2 to 200pmol/μL in concentration, same-day relative average deviations are less than 5% and bias (observed minus expected) is less than 10%. Deconvoluted mass spectra are generated for components in the predicted mass range using a maximum entropy algorithm. Mass accuracy of deconvoluted spectra is typically 20ppm or better for isotopomers of oligonucleotides up to 7000Da. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, R; Di, Z M; Chen, G L
2001-09-01
The effects of the nature and concentration of salts, pH value and competitive eluent in the mobile phase on the protein retention have been systematically investigated. A mathematical expression describing the protein retention in metal chelate chromatography has been derived. It is proposed that the eluting power of the salt solution can be expressed by the eluent strength exponent epsilon. According to the retention characters of protein under different chromatographic conditions, the interaction between the various metal chelate ligands and proteins is discussed. The protein retention on the metal chelate column is a cooperative interactions of coordination, electrostatic and hydrophobic interaction. For the strong combined metal column with proteins such as IDA-Cu, the coordination is the most important, and the electrostatic interaction is secondary in chromatographic process. However, for the weak combined metal columns with proteins such as IDA-Ni, IDA-Co and IDA-Zn, the electrostatic interaction between the metal chelate ligands and proteins is the chief one, while the coordination is the next in importance. When the mobile phase contains high concentration of salt which can't form complex with the immobilized metal, the hydrophobic interaction between the protein and stationary phase will be increased. As the interaction between the metal chelate ligand and proteins relates to chromatographic operating conditions closely, different elution processes may be selected for different metal chelate columns. The gradient elution is generally performed by the low concentration of salt or different pH for weakly combined columns with proteins, however the competitive elution procedure is commonly utilized for strongly combined column. The experiment showed that NH3 is an excellent competitive eluent. It isn't only give the efficient separation of proteins, but also has the advantages of cheapness, less bleeding of the immobilized metals and ease of controlling NH3 concentration. The interaction between the metal chelate ligand and proteins and the selectivity of metal chelate chromatography can be changed through changing chromatographic conditions.
NASA Astrophysics Data System (ADS)
Hersey, S. P.; DiVerdi, R.; Gadtaula, P.; Sheneman, T.; Flores, K.; Chen, Y. H.; Jayne, J. T.; Cross, E. S.
2017-12-01
Throughout the 2016-2017 academic year, a new partnership between Olin College of Engineering and Aerodyne Research, Inc. developed an affordable, self-contained air quality monitoring instrument called Modulair. The Modulair instrument is based on the same operating principles as Aerodyne's newly-developed ARISense integrated sensor system, employing electrochemical sensors for gas-phase measurements of CO, NO, NO2, and O3 and an off-the-shelf optical particle counter for particle concentration, number, and size distribution information (0.4 < dp < 17 microns). High Dimensional Model Representation (HDMR) has been used to model the interference derived from relative humidity and temperature as well as the cross-sensitivity of the electrochemical sensors to non-target gas-phase species. The aim of the modeling effort is to provide transparent and robust calibration of electrical signals to pollutant concentrations from a set of electrochemical sensors. Modulair was designed from the ground-up, with custom electronics - including a more powerful microcontroller, a fully re-designed housing and a device-specific backend with a mobile, cloud-based data management system for real-time data posting and analysis. Open source tools and software were utilized in the development of the instrument. All initial work was completed by a team of undergraduate students as part of the Senior Capstone Program in Engineering (SCOPE) at Olin College. Deployment strategies for Modulair include distributed, mobile measurements and drone-based aerial sampling. Design goals for the drone integration include maximizing airborne sampling time and laying the foundation for software integration with the drone's autopilot system to allow for autonomous plume sampling across concentration gradients. Modulair and its flexible deployments enable real-time mapping of air quality data at exposure-relevant spatial scales, as well as regular, autonomous characterization of sources and dispersion of atmospheric pollutants. We will present an overview of the Modulair instrument and results from benchtop and field validation, including mobile and drone-based plume sampling in the Boston area.
Communication: Slow relaxation, spatial mobility gradients, and vitrification in confined films.
Mirigian, Stephen; Schweizer, Kenneth S
2014-10-28
Two decades of experimental research indicate that spatial confinement of glass-forming molecular and polymeric liquids results in major changes of their slow dynamics beginning at large confinement distances. A fundamental understanding remains elusive given the generic complexity of activated relaxation in supercooled liquids and the major complications of geometric confinement, interfacial effects, and spatial inhomogeneity. We construct a predictive, quantitative, force-level theory of relaxation in free-standing films for the central question of the nature of the spatial mobility gradient. The key new idea is that vapor interfaces speed up barrier hopping in two distinct, but coupled, ways by reducing near surface local caging constraints and spatially long range collective elastic distortion. Effective vitrification temperatures, dynamic length scales, and mobile layer thicknesses naturally follow. Our results provide a unified basis for central observations of dynamic and pseudo-thermodynamic measurements.
Communication: slow relaxation, spatial mobility gradients, and vitrification in confined films
Mirigian, Stephen; Schweizer, Kenneth S.
2014-10-31
Two decades of experimental research indicate that spatial confinement of glass-forming molecular and polymeric liquids results in major changes of their slow dynamics beginning at large confinement distances. A fundamental understanding remains elusive given the generic complexity of activated relaxation in supercooled liquids and the major complications of geometric confinement, interfacial effects, and spatial inhomogeneity. For this research, we construct a predictive, quantitative, force-level theory of relaxation in free-standing films for the central question of the nature of the spatial mobility gradient. The key new idea is that vapor interfaces speed up barrier hopping in two distinct, but coupled, waysmore » by reducing near surface local caging constraints and spatially long range collective elastic distortion. Effective vitrification temperatures, dynamic length scales, and mobile layer thicknesses naturally follow. In conclusion, our results provide a unified basis for central observations of dynamic and pseudo-thermodynamic measurements.« less
Rapid and sensitive method for determination of withaferin-A in human plasma by HPLC.
Patial, Pankaj; Gota, Vikram
2011-02-01
To develop and validate a rapid and sensitive high-performance liquid chromatographic method for determination of withaferin-A in human plasma. Withaferin-A, the active molecule of a traditional Indian herb, has demonstrated several biological activities in preclinical models. A validated bioassay is not available for its pharmacokinetic evaluation. The chromatographic system used a reverse-phase C18 column with UV-visible detection at 225 nm. The mobile phase consisted of water and acetonitrile applied in a gradient flow. Withaferin-A was extracted by simple protein-precipitation technique. The calibration curve was linear in the concentration range of 0.05-1.6 µg/ml. The method has the desired sensitivity to detect the plasma concentration range of withaferin-A that is likely to show biological activity based on in vitro data. This is the first HPLC method ever described for the estimation of withaferin-A in human plasma which could be applied for pharmacokinetic studies.
EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.
2013-01-01
Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049
Numerical analysis of azimuthal rotating spokes in a crossed-field discharge plasma
NASA Astrophysics Data System (ADS)
Kawashima, R.; Hara, K.; Komurasaki, K.
2018-03-01
Low-frequency rotating spokes are obtained in a cross-field discharge plasma using two-dimensional numerical simulations. A particle-fluid hybrid model is used to model the plasma flow in a configuration similar to a Hall thruster. It has been reported that the drift-diffusion approximation for an electron fluid results in an ill-conditioned matrix when solving for the potential because of the differences in the electron mobilities across the magnetic field and in the direction of the E × B drift. In this paper, we employ a hyperbolic approach that enables stable calculation, namely, better iterative convergence of the electron fluid model. Our simulation results show a coherent rotating structure propagating in the E × B direction with a phase velocity of 2500 m s‑1, which agrees with experimental data. The phase velocity obtained from the numerical simulations shows good agreement with that predicted by the dispersion relation of the gradient drift instability.
Novak, Ana; Gutiérrez-Zamora, Mercè; Domenech, Lluís; Suñé-Negre, Josep M; Miñarro, Montserrat; García-Montoya, Encarna; Llop, Josep M; Ticó, Josep R; Pérez-Lozano, Pilar
2018-02-01
A simple analytical method for simultaneous determination of phytosterols, cholesterol and squalene in lipid emulsions was developed owing to increased interest in their clinical effects. Method development was based on commonly used stationary (C 18 , C 8 and phenyl) and mobile phases (mixtures of acetonitrile, methanol and water) under isocratic conditions. Differences in stationary phases resulted in peak overlapping or coelution of different peaks. The best separation of all analyzed compounds was achieved on Zorbax Eclipse XDB C 8 (150 × 4.6 mm, 5 μm; Agilent) and ACN-H 2 O-MeOH, 80:19.5:0.5 (v/v/v). In order to achieve a shorter time of analysis, the method was further optimized and gradient separation was established. The optimized analytical method was validated and tested for routine use in lipid emulsion analyses. Copyright © 2017 John Wiley & Sons, Ltd.
Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.
Valto, Piia; Knuutinen, Juha; Alén, Raimo
2011-04-01
A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Carranco, Núria; Farrés-Cebrián, Mireia; Saurina, Javier
2018-01-01
High performance liquid chromatography method with ultra-violet detection (HPLC-UV) fingerprinting was applied for the analysis and characterization of olive oils, and was performed using a Zorbax Eclipse XDB-C8 reversed-phase column under gradient elution, employing 0.1% formic acid aqueous solution and methanol as mobile phase. More than 130 edible oils, including monovarietal extra-virgin olive oils (EVOOs) and other vegetable oils, were analyzed. Principal component analysis results showed a noticeable discrimination between olive oils and other vegetable oils using raw HPLC-UV chromatographic profiles as data descriptors. However, selected HPLC-UV chromatographic time-window segments were necessary to achieve discrimination among monovarietal EVOOs. Partial least square (PLS) regression was employed to tackle olive oil authentication of Arbequina EVOO adulterated with Picual EVOO, a refined olive oil, and sunflower oil. Highly satisfactory results were obtained after PLS analysis, with overall errors in the quantitation of adulteration in the Arbequina EVOO (minimum 2.5% adulterant) below 2.9%. PMID:29561820
Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric
2017-08-15
A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Phased Arrays of Ground and Airborne Mobile Terminals for Satellite Communications
NASA Technical Reports Server (NTRS)
Huang, John
1996-01-01
Phased array antenna is beginning to play an important in the arena of mobile/satellite communications. Two examples of mobile terminal phased arrays will be shown. Their technical background, challenges, and cost drivers will be discussed. A possible solution to combat some of the deficiencies of the conventional phased array by exploiting the phased reflectarray technology will be briefly presented.
NASA Astrophysics Data System (ADS)
Vaxelaire, N.; Kovacova, V.; Bernasconi, A.; Le Rhun, G.; Alvarez-Murga, M.; Vaughan, G. B. M.; Defay, E.; Gergaud, P.
2016-09-01
A direct quantification of a structural in-depth composition in the lead zirconate titanate Pb(Zr,Ti)O3 thin films of morphotropic composition has been conducted using the newly available X-ray nano-pencil beam (i.e., beam size of 100 nm × 1 μm) diffraction approach. We tested two samples with different Zr/Ti chemical gradients. Here, we demonstrate the presence of a significant microstructural gradient between the rhombohedral and tetragonal phases through PbZrxTi1-xO3 (PZT) films with a 100 nm in-depth resolution. The phase gradient extends over around 350 nm, and it is repeated through the PZT film three times, which corresponds to the number of thermal annealings. Moreover, this microstructural gradient is in agreement with the Zr/Ti chemical gradient observed by the secondary ion mass spectroscopy (SIMS). Indeed, the quantity of tetragonal phases rises in the Ti-rich zones as revealed by SIMS, and the quantity of rhombohedral phases rises in the Zr-rich zones. We also demonstrated a huge difference in the in-depth phase variation between the two tested samples. The gradient free sample still contains 4.7% of phase variation through the film and the amplified gradient contains 9.6% of phase variation through the film. Knowing that the gradient free sample shows better electric and piezoelectric coefficients, one can draw a correlation between the chemical composition, crystallographic homogeneity, and electro-mechanical properties of the film. The more close the film is to the morphotropic composition and the more it is crystallographically homogeneous, the higher the piezoelectric coefficients of the PZT are. Finally, the adequate knowledge of phase variation and its relation to the fabrication technique are crucial for the enhancement of the PZT electro-mechanical properties. Our methodology and findings open up new perspectives in establishing a relevant quantitative feedback to reach an ultimate electro-mechanical coupling in the sol-gel PZT thin films.
Goto, Tomomi; Mikami, Eiichi; Ohno, Tsutomu; Matsumoto, Hiroshi
2002-04-01
A high-performance liquid chromatographic (HPLC) method for the simultaneous analysis of triamterene, trichlormethiazide, furosemide and spironolactone is presented for application in the examination of health food supplements advertising weight reduction and in the analysis of pharmaceuticals. The HPLC assay was performed under gradient conditions using a Wakosil ODS 5C18 column (5 microns, 150 x 4.6 mm i.d.). The mobile phase consisted of a gradient program with a mixture of water and acetonitrile containing 0.1% triethylamine adjusted with phosphoric acid to pH 3.0: from 0 to 6 min, 15% acetonitrile; from 6 to 20 min, linear gradient from 15 to 50% acetonitrile; and from 20 to 40 min, 50% acetonitrile. The column effluent was monitored from 0 to 20 min at 260 nm and from 20 to 40 min at 235 nm. The calibration curves of the four drugs showed good linearity and the correlation coefficients were better than 0.999 in all cases. The lower limits of detection were approximately 40 ng for each drug. Commercially available health food supplements and pharmaceuticals were analyzed after extraction with a mixture of methanol and acetic acid (99:1). The procedure described here is suitable for the screening of four diuretic drugs in adulterated supplements and for the quality control of pharmaceuticals with minimal sample preparation.
Arumugam, Abiramasundari; Joshi, Amita; Vasu, Kamala K
2017-11-01
The present work focused on the application of design of experiment (DoE) principles to the development and optimization of a stability-indicating method (SIM) for the drug imidapril hydrochloride and its degradation products (DPs). The resolution of peaks for the DPs and their drug in a SIM can be influenced by many factors. The factors studied here were pH, gradient time, organic modifier, flow rate, molar concentration of the buffer, and wavelength, with the aid of a Plackett-Burman design. Results from the Plackett-Burman study conspicuously showed influence of two factors, pH and gradient time, on the analyzed response, particularly, the resolution of the closely eluting DPs (DP-5 and DP-6) and the retention time of the last peak. Optimization of the multiresponse processes was achieved through Derringer's desirability function with the assistance of a full factorial design. Separation was achieved using a C18 Phenomenex Luna column (250 × 4.6 mm id, 5 µm particle size) at a flow rate of 0.8 mL/min at 210 nm. The optimized mobile phase composition was ammonium-acetate buffer (pH 5) in pump A and acetonitrile-methanol (in equal ratio) in pump B with a run time of 40 min using a gradient method.
Simulated molecular-scale interaction of supercritical fluid mobile and stationary phases.
Siders, Paul D
2017-12-08
In supercritical fluid chromatography, molecules from the mobile phase adsorb on the stationary phase. Stationary-phase alkylsilane-terminated silica surfaces might adsorb molecules at the silica, among the silanes, on a silane layer, or in pore space between surfaces. Mobile phases of carbon dioxide, pure and modified with methanol, and stationary phases were simulated at the molecular scale. Classical atomistic force fields were used in Gibbs-ensemble hybrid Monte Carlo calculations. Excess adsorption of pure carbon dioxide mobile phase peaked at fluid densities of 0.002-0.003Å -3 . Mobile phase adsorption from 7% methanol in carbon dioxide peaked at lower fluid density. Methanol was preferentially adsorbed from the mixed fluid. Surface silanes prevented direct interaction of fluid-phase molecules with silica. Some adsorbed molecules mixed with tails of bonded silanes; some formed layers above the silanes. Much adsorption occurred by filling the space between surfaces in the stationary-phase model. The distribution in the stationary phase of methanol molecules from a modified fluid phase varied with pressure. Copyright © 2017 Elsevier B.V. All rights reserved.
Downes, Katherine; Terry, Leon A
2010-06-30
Onion soluble non-structural carbohydrates consist of fructose, glucose and sucrose plus fructooligosaccharides (FOS) with degrees of polymerisation (DP) in the range of 3-19. In onion, sugars and FOS are typically separated using liquid chromatography (LC) with acetonitrile (ACN) as a mobile phase. In recent times, however, the production of ACN has diminished due, in part, to the current worldwide economic recession. A study was therefore undertaken, to find an alternative LC method to quantify sugars and FOS from onion without the need for ACN. Two mobile phases were compared; the first taken from a paper by Vågen and Slimestad (2008) using ACN mobile phase, the second, a newly reported method using ethanol (EtOH). The EtOH mobile phase eluted similar concentrations of all FOS compared to the ACN mobile phase. In addition, limit of detection, limit of quantification and relative standard deviation values were sufficiently and consistently lower for all FOS using the EtOH mobile phase. The drawback of the EtOH mobile phase was mainly the inability to separate all individual sugar peaks, yet FOS could be successfully separated. However, using the same onion extract, a previously established LC method based on an isocratic water mobile phase could be used in a second run to separate sugars. Although the ACN mobile phase method is more convenient, in the current economic climate a method based on inexpensive and plentiful ethanol is a valid alternative and could potentially be applied to other fresh produce types. In addition to the mobile phase solvent, the effect of extraction solvents on sugar and FOS concentration was also investigated. EtOH is still widely used to extract sugars from onion although previous literature has concluded that MeOH is a superior solvent. For this reason, an EtOH-based extraction method was compared with a MeOH-based method to extract both sugars and FOS. The MeOH-based extraction method was more efficacious at extracting sugars and FOS from onion flesh, eluting significantly higher concentrations of glucose, kestose, nystose and DP5-DP8. Copyright 2010 Elsevier B.V. All rights reserved.
Ikuta, N; Yamada, Y; Hirokawa, T
2000-01-01
For capillary zone electrophoresis, a new method of transformation from migration time to effective mobility was proposed, in which the mobility increase due to Joule heating and the relaxation effect of the potential gradient were eliminated successfully. The precision of the mobility evaluated by the proposed transformation was discussed in relation to the analysis of rare earth ions. By using the transformation, almost the same pherograms could be obtained even from the pherograms obtained originally at different applied voltages.
Gradient stationary phase optimized selectivity liquid chromatography with conventional columns.
Chen, Kai; Lynen, Frédéric; Szucs, Roman; Hanna-Brown, Melissa; Sandra, Pat
2013-05-21
Stationary phase optimized selectivity liquid chromatography (SOSLC) is a promising technique to optimize the selectivity of a given separation. By combination of different stationary phases, SOSLC offers excellent possibilities for method development under both isocratic and gradient conditions. The so far available commercial SOSLC protocol utilizes dedicated column cartridges and corresponding cartridge holders to build up the combined column of different stationary phases. The present work is aimed at developing and extending the gradient SOSLC approach towards coupling conventional columns. Generic tubing was used to connect short commercially available LC columns. Fast and base-line separation of a mixture of 12 compounds containing phenones, benzoic acids and hydroxybenzoates under both isocratic and linear gradient conditions was selected to demonstrate the potential of SOSLC. The influence of the connecting tubing on the deviation of predictions is also discussed.
On the relation between phase-field crack approximation and gradient damage modelling
NASA Astrophysics Data System (ADS)
Steinke, Christian; Zreid, Imadeddin; Kaliske, Michael
2017-05-01
The finite element implementation of a gradient enhanced microplane damage model is compared to a phase-field model for brittle fracture. Phase-field models and implicit gradient damage models share many similarities despite being conceived from very different standpoints. In both approaches, an additional differential equation and a length scale are introduced. However, while the phase-field method is formulated starting from the description of a crack in fracture mechanics, the gradient method starts from a continuum mechanics point of view. At first, the scope of application for both models is discussed to point out intersections. Then, the analysis of the employed mathematical methods and their rigorous comparison are presented. Finally, numerical examples are introduced to illustrate the findings of the comparison which are summarized in a conclusion at the end of the paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raats, P.A.C.
1975-12-01
Balances of mass for the water in N distinct phases and a balance of heat for the medium as a whole were formulated. Following Philip and de Vries, it was assumed that the flux of water in each phase is proportional to the gradient of the pressure in that phase and that the diffusive component of the flux of heat is proportional to the gradient of the temperature. Clapeyron equations were used to express the gradient of the pressure in any phase in terms of the gradient of the pressure in a reference state and of the temperature. The referencemore » state may be the water in one of the phases or the water in some measuring device such as a tensiometer or a psychrometer. Expressions for the total flux of water and for the diffusive flux of heat plus the convective flux of heat associated with the conversion from any phase to the reference state were shown to satisfy the onsager reciprocal relations. A theorem due to Meixner was used to delineate the class of fluxes and forces that preserves these relations. In particular, it was shown that if the gradients of water content and temperature are used as the driving forces, the onsager relations are no longer satisfied.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-31
... Mobility Fund Phase I support they seek, including any agreements relating to post-auction market structure... FEDERAL COMMUNICATIONS COMMISSION [AU Docket No. 12-25; DA 12-641 and DA 12-721] Mobility Fund... million in one-time Mobility Fund Phase I support scheduled to commence on September 27, 2012. The Bureaus...
Wiese, Steffen; Teutenberg, Thorsten; Schmidt, Torsten C
2011-09-28
In the present work it is shown that the linear elution strength (LES) model which was adapted from temperature-programming gas chromatography (GC) can also be employed to predict retention times for segmented-temperature gradients based on temperature-gradient input data in liquid chromatography (LC) with high accuracy. The LES model assumes that retention times for isothermal separations can be predicted based on two temperature gradients and is employed to calculate the retention factor of an analyte when changing the start temperature of the temperature gradient. In this study it was investigated whether this approach can also be employed in LC. It was shown that this approximation cannot be transferred to temperature-programmed LC where a temperature range from 60°C up to 180°C is investigated. Major relative errors up to 169.6% were observed for isothermal retention factor predictions. In order to predict retention times for temperature gradients with different start temperatures in LC, another relationship is required to describe the influence of temperature on retention. Therefore, retention times for isothermal separations based on isothermal input runs were predicted using a plot of the natural logarithm of the retention factor vs. the inverse temperature and a plot of the natural logarithm of the retention factor vs. temperature. It could be shown that a plot of lnk vs. T yields more reliable isothermal/isocratic retention time predictions than a plot of lnk vs. 1/T which is usually employed. Hence, in order to predict retention times for temperature-gradients with different start temperatures in LC, two temperature gradient and two isothermal measurements have been employed. In this case, retention times can be predicted with a maximal relative error of 5.5% (average relative error: 2.9%). In comparison, if the start temperature of the simulated temperature gradient is equal to the start temperature of the input data, only two temperature-gradient measurements are required. Under these conditions, retention times can be predicted with a maximal relative error of 4.3% (average relative error: 2.2%). As an example, the systematic method development for an isothermal as well as a temperature gradient separation of selected sulfonamides by means of the adapted LES model is demonstrated using a pure water mobile phase. Both methods are compared and it is shown that the temperature-gradient separation provides some advantages over the isothermal separation in terms of limits of detection and analysis time. Copyright © 2011 Elsevier B.V. All rights reserved.
Diffusion models for corona formation in metagabbros from the Western Grenville Province, Canada
NASA Astrophysics Data System (ADS)
Grant, Shona M.
1988-01-01
Metagabbro bodies in SW Grenville Province display a variety of disequilibrium corona textures between spinel-clouded plagioclase and primary olivine or opaque oxide. Textural evidence favours a single-stage, subsolidus origin for the olivine coronas and diffusive mass transfer is believed to have been the rate-controlling process. Irreversible thermodynamics have been used to model two different garnet symplectite-bearing corona sequences in terms of steady state diffusion. In the models the flux of each component is related to the chemical potential gradients of all diffusing species by the Onsager or L-coefficients for diffusion. These coefficients are analogous to experimentally determined diffusion coefficients ( d), but relate the flux of components to chemical potential rather than concentration gradients. The major constraint on the relative values of Onsager coefficients comes from the observed mole fraction, X, of garnet in the symplectites; in (amph-gt) symplectites X {Gt/Sym}˜0.80, compared with ˜0.75 in (cpx-gt) symplectites. Several models using simple oxide components, and two different modifications of the reactant plagioclase composition, give the following qualitative results: the very low mobility of aluminium appears to control the rate of corona formation. Mg and Fe have similar mobility, and Mg can be up to 6 8 times more mobile than sodium. Determination of calcium mobility is problematical because of a proposed interaction with cross-coefficient terms reflecting “uphill” Ca-diffusion, i.e., calcium diffusing up its own chemical potential gradient. If these terms are not introduced, it is difficult to generate the required proportions of garnet in the symplectite. However, at moderate values of the cross-coefficient ratios, Mg can be up to 4 6 times more mobile than calcium ( L MgMg/LCaCa<4 6) and calcium must be 3 4 times more mobile than aluminium ( L CaCa/LAlAl>3).
Generalized gradient algorithm for trajectory optimization
NASA Technical Reports Server (NTRS)
Zhao, Yiyuan; Bryson, A. E.; Slattery, R.
1990-01-01
The generalized gradient algorithm presented and verified as a basis for the solution of trajectory optimization problems improves the performance index while reducing path equality constraints, and terminal equality constraints. The algorithm is conveniently divided into two phases, of which the first, 'feasibility' phase yields a solution satisfying both path and terminal constraints, while the second, 'optimization' phase uses the results of the first phase as initial guesses.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy
2012-01-01
A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.
NASA Technical Reports Server (NTRS)
Schobeiri, M. T.; John, J.
1996-01-01
The turbomachinery wake flow development is largely influenced by streamline curvature and streamwise pressure gradient. The objective of this investigation is to study the development of the wake under the influence of streamline curvature and streamwise pressure gradient. The experimental investigation is carried out in two phases. The first phase involves the study of the wake behind a stationary circular cylinder (steady wake) in curved channels at positive, zero, and negative streamwise pressure gradients. The mean velocity and Reynolds stress components are measured using a X-hot-film probe. The measured quantities obtained in probe coordinates are transformed to a curvilinear coordinate system along the wake centerline and are presented in similarity coordinates. The results of the steady wakes suggest strong asymmetry in velocity and Reynolds stress components. However, the velocity defect profiles in similarity coordinates are almost symmetrical and follow the same distribution as the zero pressure gradient straight wake. The results of Reynolds stress distributions show higher values on the inner side of the wake than the outer side. Other quantities, including the decay of maximum velocity defect, growth of wake width, and wake integral parameters, are also presented for the three different pressure gradient cases of steady wake. The decay rate of velocity defect is fastest for the negative streamwise pressure gradient case and slowest for the positive pressure gradient case. Conversely, the growth of the wake width is fastest for the positive streamwise pressure gradient case and slowest for the negative streamwise pressure gradient. The second phase studies the development of periodic unsteady wakes generated by the circular cylinders of the rotating wake generator in a curved channel at zero streamwise pressure gradient. Instantaneous velocity components of the periodic unsteady wakes, measured with a stationary X-hot-film probe, are analyzed by the phase averaging techniques. The temporal distribution of velocity and Reynolds stress components obtained in a stationary frame of reference are transformed to a spatial distribution in a relative frame of reference. Profiles of phase-averaged velocity and Reynolds stress distributions in the relative frame of reference and similarity coordinates are presented. The velocity defect and Reynolds stress distributions agree with the results of the wake development behind a stationary cylinder in the curved channel at zero streamwise pressure gradient. The phase-averaged third-order correlations, presented in the relative frame of reference and similarity coordinates, show pronounced asymmetric features.
NASA Astrophysics Data System (ADS)
Woellner, Cristiano F.; Li, Zi; Freire, José A.; Lu, Gang; Nguyen, Thuc-Quyen
2013-09-01
In this paper we use a three-dimensional Pauli master equation to investigate the charge carrier mobility of a two-phase system which can mimic donor-acceptor and amorphous-crystalline bulk heterojunctions. By taking the energetic disorder of each phase, their energy offset, and domain morphology into consideration, we show that the carrier mobility can have a completely different behavior when compared to a one-phase system. When the energy offset is equal to zero, the mobility is controlled by the more disordered phase. When the energy offset is nonzero, we show that the mobility electric field dependence switches from negative to positive at a threshold field proportional to the energy offset. Additionally, the influence of morphology, through the domain size and volume ratio parameters, on the transport is investigated and an approximate analytical expression for the zero field mobility is provided.
[HPLC fingerprint of Calendula officinalis flower].
Xing, Zhan-Fen; Cheng, Hong-Da; Zhang, Ping-Ping; Gong, Lei; Ma, Li-Ya
2014-07-01
To establish an HPLC fingerprint of Calendula officinalis flower for its quality control. Hypersil ODS C18 column (250 mm x 4.6 mm, 5 μm) was used with acetonitrile and water as mobile phase in a gradient mode at the flow rate of 1.0 mL/min. The detection wavelength was 220 nm and the temperature of column was set at 35 degrees C. The similarity was analyzed with the Estimating System of Similarity on the Chinese Medicine Fingerprint Chromatogram. The HPLC fingerprint of Calendula officinalis flower containing eleven peaks was set up. The similarity of Calendula officinalis flower from different habitats was greater than 0.90. This method is easy and reliable, which can be used to judge the habitat and control the quality of Calendula officinalis flower.
Determination of para red, Sudan dyes, canthaxanthin, and astaxanthin in animal feeds using UPLC.
Hou, Xiaolin; Li, Yonggang; Wu, Guojuan; Wang, Lei; Hong, Miao; Wu, Yongnin
2010-01-01
A simple high-performance liquid chromatography method was developed for quantitative determination of para red, Sudan I, Sudan II, Sudan III, Sudan IV, canthaxanthin, and astaxanthin in feedstuff. The sample was extracted using acetonitrile and cleaned up on a C(18) SPE column. The residues were analyzed using ultra-performance liquid chromatography coupled to a diode array detector at 500 nm. The mobile phase was acetonitrile-formic acid-water with a gradient elution condition. The external standard curves were calibrated. The mean recoveries of the seven colorants were 62.7-91.0% with relative standard deviation 2.6-10.4% (intra-day) and 4.0-13.2% (inter-day). The detection limits were in the range of 0.006-0.02 mg/kg.
[Simultaneous determination of five active constitutents in Xiaochaihu Tang by HPLC].
Liu, Qingchun; Zhao, Junning; Yan, Liangchun; Yi, Jinhai; Song, Jun
2010-03-01
To establish a HPLC-PDA method for the determination of baicalin, wogonoside, baicalein, wogonin and glycyrrhizic acid in Xiaochaihu Tang. A Symmetry Shield RP18 (4.6 mm x 250 mm, 5.0 microm) was used with a mobile phase of acetonitrile-0.01% H3PO4 in gradient elution. The detection wavelength was 251 nm,the flow rate was 0.45 mL x min(-1) and the column temperature was maintained at 30 degrees C. The accuracy, precision, sensitivity, specificity and linearity of this method met the requirements. The contents of the five effective fractions were determined simultaneously. The method is rapid,simple and accurate and it can be suitable for the determination of baicalin, wogonoside, baicalein, wogonin and glycyrrhizic acid in Xiaochaihu Tang simultaneously.
[UPLC characteristic chromatographic profile of Poria].
Zhang, Qi; Wang, Zhenzhong; Xiao, Wei; Zhang, Liangqi; Bi, Kaishun; Jia, Ying
2012-04-01
To establish a UPLC characteristic chromatographic profile analysis method to quickly assess Poria quality and provide basis fro controlling Poria quality. The UPLC characteristic chromatographic profiles of fifteen batches of Poria were determined by ACQUITY UPLC, with HSS T3 Column (2.1 mm x 100 mm, 1.8 microm) eluted with the mobile phases of water containing 0.05% phosphoric acid and acetonitrile in gradient mode. The detection wavelength was set at 243 nm. The common mode of the UPLC characteristic chromatographic profile was set up. There were 20 common peaks, seven of which were identified, and the similar degrees of the fifteen samples to the common mode were between 0.787 and 0.974. The method was so time-saving that it can be used for the quality control of Poria.
NASA Astrophysics Data System (ADS)
Clark, L.; Brown, H. G.; Paganin, D. M.; Morgan, M. J.; Matsumoto, T.; Shibata, N.; Petersen, T. C.; Findlay, S. D.
2018-04-01
The rigid-intensity-shift model of differential-phase-contrast imaging assumes that the phase gradient imposed on the transmitted probe by the sample causes the diffraction pattern intensity to shift rigidly by an amount proportional to that phase gradient. This behavior is seldom realized exactly in practice. Through a combination of experimental results, analytical modeling and numerical calculations, using as case studies electron microscope imaging of the built-in electric field in a p-n junction and nanoscale domains in a magnetic alloy, we explore the breakdown of rigid-intensity-shift behavior and how this depends on the magnitude of the phase gradient and the relative scale of features in the phase profile and the probe size. We present guidelines as to when the rigid-intensity-shift model can be applied for quantitative phase reconstruction using segmented detectors, and propose probe-shaping strategies to further improve the accuracy.
NASA Astrophysics Data System (ADS)
Haoxiang, Chen; Qi, Chengzhi; Peng, Liu; Kairui, Li; Aifantis, Elias C.
2015-12-01
The occurrence of alternating damage zones surrounding underground openings (commonly known as zonal disintegration) is treated as a "far from thermodynamic equilibrium" dynamical process or a nonlinear continuous phase transition phenomenon. The approach of internal variable gradient theory with diffusive transport, which may be viewed as a subclass of Landau's phase transition theory, is adopted. The order parameter is identified with an irreversible strain quantity, the gradient of which enters into the expression for the free energy of the rock system. The gradient term stabilizes the material behavior in the post-softening regime, where zonal disintegration occurs. The results of a simplified linearized analysis are confirmed by the numerical solution of the nonlinear problem.
Assessing the scalability of dynamic field gradient focusing by linear modeling
Tracy, Noah I.; Ivory, Cornelius F.
2010-01-01
Dynamic field gradient focusing (DFGF) separates and concentrates proteins in native buffers, where proteins are most soluble, using a computer-controlled electric field gradient which lets the operator adjust the pace and resolution of the separation in real-time. The work in this paper assessed whether DFGF could be scaled up from microgram analytical-scale protein loads to milligram preparative-scale loads. Linear modeling of the electric potential, protein transport, and heat transfer simulated the performance of a preparative-scale DFGF instrument. The electric potential model showed where the electrodes should be placed to optimize the shape and strength of the electric field gradient. Results from the protein transport model suggested that in 10 min the device should separate 10 mg each of two proteins whose electrophoretic mobilities differ by 5 ×. Proteins with electrophoretic mobilities differing by only 5% should separate in 3 h. The heat transfer model showed that the preparative DFGF design could dissipate 1 kW of Joule heat while keeping the separation chamber at 25°C. Model results pointed to DFGF successfully scaling up by 1000 × using the proposed instrument design. PMID:18196522
Developing operation algorithms for vision subsystems in autonomous mobile robots
NASA Astrophysics Data System (ADS)
Shikhman, M. V.; Shidlovskiy, S. V.
2018-05-01
The paper analyzes algorithms for selecting keypoints on the image for the subsequent automatic detection of people and obstacles. The algorithm is based on the histogram of oriented gradients and the support vector method. The combination of these methods allows successful selection of dynamic and static objects. The algorithm can be applied in various autonomous mobile robots.
He, Gaoli; Guo, Beining; Zhang, Jing; Li, Yi; Wu, Xiaojie; Fan, Yaxin; Chen, Yuancheng; Cao, Guoying; Yu, Jicheng
2018-04-01
Levornidazole is a novel third-generation nitroimidazoles antibiotic which metabolism and disposition in human are not well known. We have previously developed two methods to quantify levornidazole and its phase I metabolites, Ml (Hydroxylation metabolite), M2 (N-dealkylation metabolite) and M4 (Oxidative dechlorination metabolite), in human plasma and urine. In this study, we developed three novel liquid chromatographic-tandem mass spectrometric (LC-MS/MS) methods and analyzed its phase II metabolites, sulfate conjugate (M6) and glucuronide conjugate (M16), in human plasma and urine, and the parent drug and above-mentioned five metabolites in human feces samples. Analytes and internal standard (IS) in human plasma were extracted by a solid-phase extraction procedure and separated on an ACQUITY UPLC CSH C18 column in gradient elution using acetonitrile and 0.1% formic acid aqueous solution as the mobile phase. The pretreatment procedures for urine and feces homogenate samples involved a protein precipitation followed by liquid-liquid extraction, and chromatographic separations were performed on the Atlantis T3 columns of different lengths and particle sizes (2.1 × 50 mm, 3 μm and 2.1 × 150 mm, 5 μm), respectively. The mobile phases consisted of formic acid and acetonitrile-methanol solution (v/v, 50:50) in gradient elution. The MS/MS analysis was conducted on TSQ Quantum triple quadrupole mass spectrometer using electrospray ionization with selected reaction monitoring (SRM) in the positive ion mode. The calibration curves for all analytes were linear and the validation ranges were as follows: 0.005-0.500 μg/mL for M6 and 0.005-2.500 μg/mL for M16 in plasma; 0.010-10.000 μg/mL for M6 and M16 in urine; 0.005-1.000 μg/mL for levornidazole, M2, M4 and M16, and 0.010-2.000 μg/mL for M1 and M6 in human feces homogenate. Across these matrices, mean intra- and inter- batch accuracy values were in the ranges of 80.0%-120.0%, and intra- and inter-batch precision values did not exceed 20%. It was fully validated including selectivity, linearity, matrix effect, extraction recovery, stability, dilution integrity, carryover and incurred sample analysis (ISR). These newly developed methods were successfully applied in pharmacokinetics, metabolism and disposition study of levornidazole in 12 healthy Chinese subjects. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Perron, Aurelien; Roehling, John D.; Turchi, Patrice E. A.; Fattebert, Jean-Luc; McKeown, Joseph T.
2018-01-01
A combination of dynamic transmission electron microscopy (DTEM) experiments and CALPHAD-informed phase-field simulations was used to study rapid solidification in Cu-Ni thin-film alloys. Experiments—conducted in the DTEM—consisted of in situ laser melting and determination of the solidification kinetics by monitoring the solid-liquid interface and the overall microstructure evolution (time-resolved measurements) during the solidification process. Modelling of the Cu-Ni alloy microstructure evolution was based on a phase-field model that included realistic Gibbs energies and diffusion coefficients from the CALPHAD framework (thermodynamic and mobility databases). DTEM and post mortem experiments highlighted the formation of microsegregation-free columnar grains with interface velocities varying from ˜0.1 to ˜0.6 m s-1. After an ‘incubation’ time, the velocity of the planar solid-liquid interface accelerated until solidification was complete. In addition, a decrease of the temperature gradient induced a decrease in the interface velocity. The modelling strategy permitted the simulation (in 1D and 2D) of the solidification process from the initially diffusion-controlled to the nearly partitionless regimes. Finally, results of DTEM experiments and phase-field simulations (grain morphology, solute distribution, and solid-liquid interface velocity) were consistent at similar time (μs) and spatial scales (μm).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perron, Aurelien; Roehling, John D.; Turchi, Patrice E. A.
A combination of dynamic transmission electron microscopy (DTEM) experiments and CALPHAD-informed phase-field simulations was used to study rapid solidification in Cu–Ni thin-film alloys. Experiments—conducted in the DTEM—consisted of in situ laser melting and determination of the solidification kinetics by monitoring the solid–liquid interface and the overall microstructure evolution (time-resolved measurements) during the solidification process. Modelling of the Cu–Ni alloy microstructure evolution was based on a phase-field model that included realistic Gibbs energies and diffusion coefficients from the CALPHAD framework (thermodynamic and mobility databases). DTEM and post mortem experiments highlighted the formation of microsegregation-free columnar grains with interface velocities varying frommore » ~0.1 to ~0.6 m s –1. After an 'incubation' time, the velocity of the planar solid–liquid interface accelerated until solidification was complete. In addition, a decrease of the temperature gradient induced a decrease in the interface velocity. The modelling strategy permitted the simulation (in 1D and 2D) of the solidification process from the initially diffusion-controlled to the nearly partitionless regimes. Lastly, results of DTEM experiments and phase-field simulations (grain morphology, solute distribution, and solid–liquid interface velocity) were consistent at similar time (μs) and spatial scales (μm).« less
Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi
2008-03-10
Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.
Perron, Aurelien; Roehling, John D.; Turchi, Patrice E. A.; ...
2017-12-05
A combination of dynamic transmission electron microscopy (DTEM) experiments and CALPHAD-informed phase-field simulations was used to study rapid solidification in Cu–Ni thin-film alloys. Experiments—conducted in the DTEM—consisted of in situ laser melting and determination of the solidification kinetics by monitoring the solid–liquid interface and the overall microstructure evolution (time-resolved measurements) during the solidification process. Modelling of the Cu–Ni alloy microstructure evolution was based on a phase-field model that included realistic Gibbs energies and diffusion coefficients from the CALPHAD framework (thermodynamic and mobility databases). DTEM and post mortem experiments highlighted the formation of microsegregation-free columnar grains with interface velocities varying frommore » ~0.1 to ~0.6 m s –1. After an 'incubation' time, the velocity of the planar solid–liquid interface accelerated until solidification was complete. In addition, a decrease of the temperature gradient induced a decrease in the interface velocity. The modelling strategy permitted the simulation (in 1D and 2D) of the solidification process from the initially diffusion-controlled to the nearly partitionless regimes. Lastly, results of DTEM experiments and phase-field simulations (grain morphology, solute distribution, and solid–liquid interface velocity) were consistent at similar time (μs) and spatial scales (μm).« less
First-principles study of defects and phase transition in UO(2).
Yu, Jianguo; Devanathan, Ram; Weber, William J
2009-10-28
Defect properties and phase transition in UO(2) have been studied from first principles by the all-electron projector-augmented-wave (PAW) method. The generalized gradient approximation with empirical self-interaction correction, (GGA)+U, formalism has been used to account for the strong on-site Coulomb repulsion among the localized U 5f electrons. The Hubbard parameter U(eff), magnetic ordering, chemical potential and heat of formation have been systematically examined. By choosing an appropriate U(eff) = 3.0 eV it is possible to consistently describe structural properties of UO(2) and model the phase transition processes. The phase transition pressure for UO(2) is about 20 GPa, which is less than the experimental value of 42 GPa but better than the LDA+U value of 7.8 GPa. Meanwhile our results for the formation energies of intrinsic defects partly confirm earlier calculations for the intrinsic charge neutral defects but reveal large variations depending on the determination of the chemical potential and whether the environment is O-rich or U-rich. Moreover, the results for extrinsic defects of Xe, which are representative of mobile insoluble fission product in UO(2), are consistent with experimental data in which Xe prefers to be trapped by Schottky defects.
78 FR 45071 - Annual Report for Mobility Fund Phase I Support and Record Retention
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... for Mobility Fund Phase I Support and Record Retention AGENCY: Federal Communications Commission... information collection associated with the Commission's Annual Report for Mobility Fund Phase I Support and... or sponsor a collection of information unless it displays a current, valid OMB Control Number. No...
47 CFR 54.1005 - Application process.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for Mobility Fund Phase I Support. In addition to providing information specified in § 1.21001(b) of... competitive bidding for Mobility Fund Phase I support also shall: (1) Provide ownership information as set... Mobility Fund Phase I Support—(1) Deadline. Unless otherwise provided by public notice, winning bidders for...
47 CFR 54.1005 - Application process.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for Mobility Fund Phase I support. In addition to providing information specified in § 1.21001(b) of... competitive bidding for Mobility Fund Phase I support also shall: (1) Provide ownership information as set... Mobility Fund Phase I support.—(1) Deadline. Unless otherwise provided by public notice, winning bidders...
47 CFR 54.1005 - Application process.
Code of Federal Regulations, 2014 CFR
2014-10-01
... for Mobility Fund Phase I support. In addition to providing information specified in § 1.21001(b) of... competitive bidding for Mobility Fund Phase I support also shall: (1) Provide ownership information as set... Mobility Fund Phase I support.—(1) Deadline. Unless otherwise provided by public notice, winning bidders...
Baranowska, Irena; Adolf, Weronika; Magiera, Sylwia
2015-11-01
A sensitive, stereoselective assay using solid phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection (FLD) was developed and validated for the analysis of enantiomers of metoprolol and its metabolites (α-hydroxymetoprolol, O-desmethylmetoprolol). Chiral separation was achieved using a CHIRALCEL OD-RH column, packed with cellulose tris-(3,5-dimethylphenyl-carbamate) stationary phase, employing a mobile phase composed by a mixture of 0.2% diethylamine in water and acetonitrile in gradient elution mode. Linear calibration curves were obtained over the range of 0.025-2.0μg/mL (R(2)>0.994) in urine for both enantiomers of metoprolol and its metabolites with quantitation limit of 0.025μg/mL. Intra and inter-day precision and accuracy were below 15% for both metoprolol and metabolites enantiomers. The recovery of enantiomer of metoprolol and its metabolite was greater than 68.0%, utilizing a SPE procedure. The method was tested with urine quality control samples and human urine fractions after administration of 50mg rac-metoprolol. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhang, Juzhou; Li, Jing; Shao, Dongliang; Yao, Bangben; Jiang, Junshu
2012-02-01
An effective high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials. The food packaging samples were firstly extracted by methanol-ethyl acetate, and then purified by a C18 solid-phase extraction (SPE) column. The target compounds were separated on a ZORBAX SB-C18 column (250 mm x 4.6 mm, 5 microm) in gradient elution mode using methanol and water as mobile phases. The detection wavelength was at 310 nm. The linear plots of the nine ultraviolet stabilizers were obtained between 0.2 and 10 mg/L, with the correlation coefficients of above 0. 999 for the nine ultraviolet stabilizers. The limits of detection for this method were in the range from 0.05 to 0.1 mg/L. The recoveries spiked in commercial food plastic packaging materials were in the range of 70.2% - 89.0% with the relative standard deviations of 0.4% - 4.5%. The results indicated that the method is simple, accurate, and suitable for the simultaneous determination of the nine ultraviolet stabilizers in food plastic packaging materials.
Baños, Clara-Eugenia; Silva, Manuel
2009-03-15
A rapid and straightforward continuous solid-phase extraction system has been developed for in situ derivatization and pre-concentration of carbonyl compounds in aqueous samples. Initially 2,4-dinitrophenylhydrazine, the derivatizing agent, was adsorbed on a C(18) mini-column and then 15-ml of sample were continuously aspirated into the flow system, where the derivatization and pre-concentration of the analytes (low-molecular mass aldehydes) were performed simultaneously. Following elution, 20 microl of the extract were injected into a LC-DAD system, in which hydrazones were successfully separated in 12 min on a RP-C(18) column using a linear gradient mobile phase of acetonitrile-water of 60-100% acetonitrile for 8 min, flowing at 0.5 ml/min. The whole analytical process can be accomplished within ca. 35 min. Under optimum conditions, limits of detection were obtained between 0.3 and 1.0 microg/l and RSDs (inter-day precision) from 1.2 to 4.6%. Finally, some applications on water samples are presented with recoveries ranged from 95.8 to 99.4%.
Castillo-Pichardo, Linette; Dharmawardhane, Suranganie; Rodríguez-Orengo, José F
2014-12-01
The objective of this study was to develop a rapid and sensitive method for the quantification of resveratrol, a polyphenolic compound with multiple health beneficial effects, in mouse plasma. We used reversed-phase ultra high pressure-liquid chromatography with tandem mass spectrometry detection for the determination of resveratrol levels in mouse plasma. An Agilent Zorbax Eclipse Plus C18 column (2.1 mm x 50 mm, 1.8 μm) was used as the stationary phase. The mobile phase consisted of a gradient formed using 1 mM ammonium fluoride and methanol. Using this improved method, we obtained a retention time of 2.2 min and a total run time of 5 min, for resveratrol. The calibration curve for resveratrol showed a linear range from 0.5 to 100 ng/mL. The average coefficient of variation was 6% for interday variation and 4% for intraday variation. The recovery for resveratrol in mouse plasma was 85 ± 10% (mean ± standard deviation). The method presented herein allows a rapid and very sensitive quantification of resveratrol in mouse plasma at concentrations as low as 500 ppt.
Matějíček, David
2012-03-30
The multi-heart-cutting two-dimensional liquid chromatography-tandem mass spectrometry method using atmospheric pressure photoionization has been developed and successfully validated for the determination of nine endocrine disrupting compounds in river water. The method is based on the use of two different reverse-phase columns connected through a six-port two-position switching valve equipped with a 200 μl loop. An orthogonal separation was achieved by proper selection of stationary phases, mobile phases, and the use of a gradient elution in both dimensions. The method shows excellent performance in terms of accuracy (86.2-111.1%), precision (intra-batch: 6.7-11.2%, inter-batch: 7.2-13.5%), and sensitivity (1.2-7.1 ng l(-1)). Twenty real samples collected from the Loučka and the Svratka rivers were analyzed, the studied compounds were found in all Svratka samples (9.7-11.2 ng l(-1) for β-estradiol, 7.6-9.3 ng l(-1) for estrone, and 24.6-38.7 ng l(-1) for bisphenol A). Copyright © 2012 Elsevier B.V. All rights reserved.
A Laterally-Mobile Mixed Polymer/Polyelectrolyte Brush Undergoes a Macroscopic Phase Separation
NASA Astrophysics Data System (ADS)
Lee, Hoyoung; Park, Hae-Woong; Tsouris, Vasilios; Choi, Je; Mustafa, Rafid; Lim, Yunho; Meron, Mati; Lin, Binhua; Won, You-Yeon
2013-03-01
We studied mixed PEO and PDMAEMA brushes. The question we attempted to answer was: When the chain grafting points are laterally mobile, how will this lateral mobility influence the structure and phase behavior of the mixed brush? Two different model mixed PEO/PDMAEMA brush systems were prepared: a mobile mixed brush by spreading a mixture of two diblock copolymers, PEO-PnBA and PDMAEMA-PnBA, onto the air-water interface, and an inseparable mixed brush using a PEO-PnBA-PDMAEMA triblock copolymer having respective brush molecular weights matched to those of the diblock copolymers. These two systems were investigated by surface pressure-area isotherm, X-ray reflectivity and AFM imaging measurements. The results suggest that the mobile mixed brush undergoes a lateral macroscopic phase separation at high chain grafting densities, whereas the inseparable system is only microscopically phase separated under comparable brush density conditions. We also conducted an SCF analysis of the phase behavior of the mixed brush system. This analysis further supported the experimental findings. The macroscopic phase separation observed in the mobile system is in contrast to the microphase separation behavior commonly observed in two-dimensional laterally-mobile small molecule mixtures.
Magiera, Sylwia; Baranowska, Irena; Lautenszleger, Anna
2015-01-01
A simple and rapid ultra-high performance liquid chromatographic (UHPLC) method coupled with an ultraviolet detector (UV) has been developed and validated for the separation and determination of 14 major flavonoids ((±)-catechin, (-)-epicatechin, glycitin, (-)-epicatechin gallate, rutin, quercitrin, hesperidine, neohesperidine, daidzein, glycitein, quercetin, genistein, hesperetin, and biochanin A) in herbal dietary supplements. The flavonoids have been separated on a Chromolith Fast Gradient Monolithic RP-18e column utilizing a mobile phase composed of 0.05% trifluoroacetic acid in water and acetonitrile in gradient elution mode. Under these conditions, flavonoids were separated in a 5 min run. The selectivity of the developed UHPLC-UV method was confirmed by comparison with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The validation parameters such as linearity, sensitivity, precision, and accuracy were found to be highly satisfactory. The optimized method was applied to determination of flavonoids in different dietary supplements. Additionally, the developed HPLC-UV method combined with 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) assay was used in the evaluation of antioxidant activity of the selected flavonoids. Copyright © 2014 Elsevier B.V. All rights reserved.
[Fast identification of constituents of Lagotis brevituba by using UPLC-Q-TOF-MS/MS method].
Xie, Jing; Zhang, Li; Zeng, Jin-Xiang; Li, Min; Wang, Juan; Xie, Xiong-Xiong; Zhong, Guo-Yue; Luo, Guang-Ming; Yuan, Jin-Bin; Liang, Jian
2017-06-01
The chemical constituents of Lagotis brevituba were rapidly determined and analyzed by using ultra performance liquid chromatography tandem quadrupole time of flight mass spectrometry (UPLC-Q-TOF-MS/MS) method, providing material basis for the clinical application of L. brevituba. The separation was performed on UPLC YMC-Triart C₁₈ (2.1 mm×100 mm, 1.9 μm) column, with acetonitrile-water containing 0.2% formic acid as mobile phase for gradient elution. The flow rate was 0.4 mL•min-1 gradient elution and column temperature was 40 ℃, the injection volume was 2 μL. ESI ion source was used to ensure the data collected in a negative ion mode. The chemical components of L. brevituba were identified through retention time, exact relative molecular mass, cleavage fragments of MS/MS and reported data. The results showed that a total of 22 compounds were identified, including 11 flavones, 6 phenylethanoid glycosides, 1 iridoid glucosides, and 4 organic acid. The UPLC-Q-TOF-MS/MS method could fast identify the chemical components of L. brevituba, providing valuable information about L. brevituba for its clinical application. Copyright© by the Chinese Pharmaceutical Association.
A Microwave Flow Detector for Gradient Elution Liquid Chromatography.
Ye, Duye; Wang, Weizheng; Moline, David; Islam, Md Saiful; Chen, Feng; Wang, Pingshan
2017-10-17
This study presents a microwave flow detector technique for liquid chromatography (LC) application. The detector is based on a tunable microwave interferometer (MIM) with a vector network analyzer (VNA) for signal measurement and a computer for system control. A microstrip-line-based 0.3 μL flow cell is built and incorporated into the MIM. With syringe pump injection, the detector is evaluated by measuring a few common chemicals in DI water at multiple frequencies from 0.98 to 7.09 GHz. Less than 30 ng minimum detectable quantity (MDQ) is demonstrated. An algorithm is provided and used to obtain sample dielectric permittivity at each frequency point. When connected to a commercial HPLC system and injected with a 10 μL aliquot of 10 000 ppm caffeine DI-water solution, the microwave detector yields a signal-to-noise ratio (SNR) up to 10 under isocratic and gradient elution operations. The maximum sampling rate is 20 Hz. The measurements show that MIM tuning, aided by a digital tunable attenuator (DTA), can automatically adjust MIM operation to retain detector sensitivity when mobile phase changes. Furthermore, the detector demonstrates a capability to quantify coeluted vitamin E succinate (VES) and vitamin D 3 (VD 3 ).
Applications of the solvation parameter model in reversed-phase liquid chromatography.
Poole, Colin F; Lenca, Nicole
2017-02-24
The solvation parameter model is widely used to provide insight into the retention mechanism in reversed-phase liquid chromatography, for column characterization, and in the development of surrogate chromatographic models for biopartitioning processes. The properties of the separation system are described by five system constants representing all possible intermolecular interactions for neutral molecules. The general model can be extended to include ions and enantiomers by adding new descriptors to encode the specific properties of these compounds. System maps provide a comprehensive overview of the separation system as a function of mobile phase composition and/or temperature for method development. The solvation parameter model has been applied to gradient elution separations but here theory and practice suggest a cautious approach since the interpretation of system and compound properties derived from its use are approximate. A growing application of the solvation parameter model in reversed-phase liquid chromatography is the screening of surrogate chromatographic systems for estimating biopartitioning properties. Throughout the discussion of the above topics success as well as known and likely deficiencies of the solvation parameter model are described with an emphasis on the role of the heterogeneous properties of the interphase region on the interpretation and understanding of the general retention mechanism in reversed-phase liquid chromatography for porous chemically bonded sorbents. Copyright © 2016 Elsevier B.V. All rights reserved.
Schicks, J M; Luzi, M; Beeskow-Strauch, B
2011-11-24
Microscopy, confocal Raman spectroscopy and powder X-ray diffraction (PXRD) were used for in situ investigations of the CO(2)-hydrocarbon exchange process in gas hydrates and its driving forces. The study comprises the exposure of simple structure I CH(4) hydrate and mixed structure II CH(4)-C(2)H(6) and CH(4)-C(3)H(8) hydrates to gaseous CO(2) as well as the reverse reaction, i.e., the conversion of CO(2)-rich structure I hydrate into structure II mixed hydrate. In the case of CH(4)-C(3)H(8) hydrates, a conversion in the presence of gaseous CO(2) from a supposedly more stable structure II hydrate to a less stable structure I CO(2)-rich hydrate was observed. PXRD data show that the reverse process requires longer initiation times, and structural changes seem to be less complete. Generally, the exchange process can be described as a decomposition and reformation process, in terms of a rearrangement of molecules, and is primarily induced by the chemical potential gradient between hydrate phase and the provided gas phase. The results show furthermore the dependency of the conversion rate on the surface area of the hydrate phase, the thermodynamic stability of the original and resulting hydrate phase, as well as the mobility of guest molecules and formation kinetics of the resulting hydrate phase.
Belzunces, L P; Toutant, J P; Bounias, M
1988-01-01
The polymorphism of bee acetylcholinesterase was studied by sucrose-gradient-sedimentation analysis and non-denaturing electrophoretic analysis of fresh extracts. Lubrol-containing extracts exhibited only one form, which sedimented at 5 S when analysed on high-salt Lubrol-containing gradients and 6 S when analysed on low-salt Lubrol-containing gradients. The 5 S/6 S form aggregated upon removal of the detergent when sedimented on detergent-free gradients and was recovered in the detergent phase after Triton X-114 phase separation. Thus the 5 S/6 S enzyme corresponds to an amphiphilic acetylcholinesterase form. In detergent-free extracts three forms, whose apparent sedimentation coefficients are 14 S, 11 S and 7 S, were observed when sedimentations were performed on detergent-free gradients. Sedimentation analyses on detergent-containing gradients showed only a 5 S peak in high-salt detergent-free extracts and a 6 S peak, with a shoulder at about 7 S, in low-salt detergent-free extracts. Electrophoretic analysis in the presence of detergent demonstrated that the 14 S and 11 S peaks corresponded to aggregates of the 5 S/6 S form, whereas the 7 S peak corresponded to a hydrophilic acetylcholinesterase form which was recovered in the aqueous phase following Triton X-114 phase separation. The 5 S/6 S amphiphilic form could be converted into a 7.1 S hydrophilic form by phosphatidylinositol-specific phospholipase C digestion. Images Fig. 3. Fig. 6. PMID:2849414
Kodama, Nao; Setoi, Ayana; Kose, Katsumi
2018-01-01
Spiral MRI sequences were developed for a 9.4T vertical standard bore (54 mm) superconducting magnet using unshielded and self-shielded gradient coils. Clear spiral images with 64-shot scan were obtained with the self-shielded gradient coil, but severe shading artifacts were observed for the spiral-scan images acquired with the unshielded gradient coil. This shading artifact was successfully corrected with a phase-correction technique using reference scans that we developed based on eddy current field measurements. We therefore concluded that spiral imaging sequences can be installed even for unshielded gradient coils if phase corrections are performed using the reference scans. PMID:28367906
Kodama, Nao; Setoi, Ayana; Kose, Katsumi
2018-04-10
Spiral MRI sequences were developed for a 9.4T vertical standard bore (54 mm) superconducting magnet using unshielded and self-shielded gradient coils. Clear spiral images with 64-shot scan were obtained with the self-shielded gradient coil, but severe shading artifacts were observed for the spiral-scan images acquired with the unshielded gradient coil. This shading artifact was successfully corrected with a phase-correction technique using reference scans that we developed based on eddy current field measurements. We therefore concluded that spiral imaging sequences can be installed even for unshielded gradient coils if phase corrections are performed using the reference scans.
Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei
2015-08-01
In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.
El-Yazbi, Amira F; El-Hawiet, Amr
2017-05-01
Two simple, direct and environment-friendly chromatographic methods, high-performance liquid chromatography (HPLC) and high-performance thin layer chromatographic (HPTLC), were developed for the determination of a binary mixture of fish oil (FO) and wheat germ oil (WGO), for the first time, in their pharmaceutical dosage forms with no need for any sample pretreatment. The HPLC separation was carried out using C-18 stationary phase with mobile phase of 15% formic acid (pH 6), methanol and acetonitrile through gradient-elution, 1.5 mL min-1 flow-rate and detection at 215 nm for FO and 280 nm for WGO. HPTLC separation was carried out on silica-coated plates using diethyl ether-petroleum ether (0.5:9.5, v/v) as mobile phase. Detection was at 215 nm for FO and 240 nm for WGO. Regression analysis showed good linear relationship with r > 0.999 in the concentration-ranges of 0.2-2 mg mL-1 and 2.5-20 μg band-1 for WGO by HPLC and HPTLC methods, respectively, and 0.4-10 mg mL-1 and 25-200 μg band-1 for FO by HPLC and HPTLC methods, respectively. The methods were validated, showed good analytical performance and were successfully applied for the analysis of pharmaceutical formulations and synthetic mixtures of the analytes with good recoveries. Therefore, the two methods could be conveniently adopted for routine analysis of similar products in quality control laboratories of pharmaceutical industries especially that simultaneous determination of FO-WGO mixture has not been reported previously. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Sunil P
2012-10-01
The objective of the current investigation was to study the degradation behavior of irinotecan hydrochloride under different International Conference on Harmonization (ICH) recommended stress conditions using ultra-performance liquid chromatography and liquid chromatography-mass spectrometry and to establish a validated stability-indicating reverse-phase ultra-performance liquid chromatographic method for the quantitative determination of irinotecan hydrochloride and its seven impurities and degradation products in pharmaceutical dosage forms. Irinotecan hydrochloride was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Irinotecan hydrochloride was found to degrade significantly in oxidative and base hydrolysis and photolytic degradation conditions. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating power of the method. Chromatographic separation was achieved on a Waters Acquity BEH C8 (100 × 2.1 mm) 1.7-µm column with a mobile phase containing a gradient mixture of solvent A (0.02M KH(2)PO(4) buffer, pH 3.4) and solvent B (a mixture of acetonitrile and methanol in the ratio of 62:38 v/v). The mobile phase was delivered at a flow rate of 0.3 mL/min with ultraviolet detection at 220 nm. The run time was 8 min, within which irinotecan and its seven impurities and degradation products were satisfactorily separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of irinotecan hydrochloride in pharmaceutical dosage forms.
Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor
2011-09-01
Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.
Lu, Baiyi; Ren, Yiping; Huang, Baifen; Liao, Wenqun; Cai, Zengxuan; Tie, Xiaowei
2008-03-01
A novel ultra-performance liquid chromatography electrospray ionization tandem triple quadrupole mass spectrometry method for the simultaneous determination of four water-soluble vitamins, including vitamin B5 (VB5), vitamin B8 (VB8), vitamin B9 (VB9), and vitamin B12 (VB12) in fortified infant foods is developed and validated. A reverse phase UPLC separation system consisting of a Waters ACQUITY UPLC BEH C-18 column (2.1 mm x 100 mm i.d., 1.7 microm) and a binary gradient acetonitrile-water mobile phase is applied for the separation of the four water-soluble vitamins. Formic acid is spiked into the mobile phase to enhance the ionization efficiency. Tandem MS-MS analysis is performed in multi-reaction monitoring mode (MRM). Product-ion traces at m/z 220.1 --> 89.9 for VB5, 245.1 --> 227.1 for VB8, 442.3 --> 295.2 for VB9, and 678.9 --> 147.0 for VB12 are used for quantitation of the corresponding vitamins, and traces at m/z 455.5 --> 308.0 are used for methotrexate (internal standard). Limits of quantitation (LOQs) are 0.016, 0.090, 0.020, and 0.019 microg/L for VB5, VB8, VB9, and VB12, respectively. Intra- and inter-day precisions for the determination of the four vitamins are better than 6.84% and 12.26% in relative standard deviations, and recoveries for the four vitamins are in the range of 86.0~101.5%. The developed approach is applied for the determination of the trace amounts of the vitamins in fortified milk powers and fortified rice powers.
NASA Technical Reports Server (NTRS)
Grugel, Richard N.
2003-01-01
Porosity in the form of "bubbles and pipes" can occur during controlled directional solidification processing of metal alloys. This is a consequence that 1) precludes obtaining any meaningful scientific results and 2) is detrimental to desired material properties. Unfortunately, several Microgravity experiments have been compromised by porosity. The intent of the PFMl investigation is to conduct a systematic effort directed towards understanding porosity formation and mobility during controlled directional solidification (DS) in a microgravity environment. PFMl uses a pure transparent material, succinonitrile (SCN), as well as SCN "alloyed" with water, in conjunction with a translating temperature gradient stage so that direct observation and recording of pore generation and mobility can be made. PFMl is investigating the role of thermocapillary forces and temperature gradients in affecting bubble dynamics as well as other solidification processes in a microgravity environment. This presentation will cover the concept, hardware development, operations, and the initial results from experiments conducted aboard the International Space Station.
NASA Technical Reports Server (NTRS)
Grugel, Richard N.
2004-01-01
Porosity in the form of "bubbles and pipes" can occur during controlled directional solidification processing of metal alloys. This is a consequence that 1) precludes obtaining any meaningful scientific results and 2) is detrimental to desired material properties. Unfortunately, several Microgravity experiments have been compromised by porosity. The intent of the PFMI investigation is to conduct a systematic effort directed towards understanding porosity formation and mobility during controlled directional solidification (DS) in a microgravity environment. PFMI uses a pure transparent material, succinonitrile (SCN), as well as SCN "alloyed" with water, in conjunction with a translating temperature gradient stage so that direct observation and recording of pore generation and mobility can be made. PFMI is investigating the role of thermocapillary forces and temperature gradients in affecting bubble dynamics as well as other solidification processes in a microgravity Environment. This presentation will cover the concept, hardware development, operations, and the initial results from experiments conducted aboard the International Space Station. .
NASA Astrophysics Data System (ADS)
Qin, Tongran; Grigoriev, Roman
2017-11-01
We consider convection in a layer of binary fluid with free surface subject to a horizontal temperature gradient in the presence of noncondensable gases, which is driven by a combination of three different forces: buoyancy, thermocapillarity, and solutocapillarity. Unlike buoyancy, both thermo- and solutocapillary stresses depend sensitively on the local phase equilibrium at the liquid-gas interface. In particular, thermocapillarity associated with the interfacial temperature gradient is controlled by the vapors' concentration along the interface, and solutocapillarity associated with the interfacial concentration gradient is controlled by differential phase change of two components of the liquid, which is strongly influenced by the presence of noncondensables. Therefore, flows in both phases, phase change, and effect of noncondensables all have to be considered. Numerical simulations based on a comprehensive model taking these effects into account show qualitative agreement with recent experiments which identified a number of flow regimes at various compositions of both phases. In particular,we find that the composition of both the gas and liquid phase have a significant effect on the observed convection patterns; this dependence can be understood using a simple analytical model. This material is based upon work supported by the National Science Foundation under Grant No. 1511470.
Zhao, Shan; Zhang, Jing; Yang, Yi; Shao, Bing
2010-04-01
A method for the determination of 27 industrial dyes in juice and wine has been developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS). Acetonitrile was used as extraction solvent, and sodium chloride was added to salt out the analytes from the samples. Chromatographic separation was performed on a C18 column with the gradient elution and the mass spectrometric acquisition was carried out under the mode of multiple reaction monitoring (MRM). Twenty-four of the 27 dyes were detected under positive ionization mode using the mobile phase of acetonitrile and water containing 0.1% formic acid. The other 3 dyes were analyzed under negative ionization mode with the mobile phase of acetonitrile and water. As a result, the average recoveries of 27 dyes spiked in juice ranged from 57.0% to 117.7% with the relative standard deviations (RSDs) of 2.4%-17.7%, and the average recoveries of 27 dyes spiked in wine ranged from 40.8% to 109.4% with the RSDs of 1.6%-17.9%. The limits of quantification (LOQs) of 27 dyes spiked in juice were in the range of 0.1-50 microg/kg, and 0.2-50 microg/kg for those spiked in wine. This method can be applied to rapid detection of illegally added dyes in soft drinks due to its simplicity and high sensitivity.
Mobile quantum gravity sensor with unprecedented stability
NASA Astrophysics Data System (ADS)
Leykauf, Bastian; Freier, Christian; Schkolnik, Vladimir; Krutzik, Markus; Peters, Achim
2017-04-01
The gravimetric atom interferometer GAIN is based on interfering ensembles of laser-cooled 87Rb atoms in a fountain setup, using stimulated Raman transitions. GAIN's rugged design allows for transports to sites of geodetic and geophysical interest while maintaining a high accuracy compatible with the best classical instruments. We compared our instrument's performance with falling corner-cube and superconducting gravimeters in two measurement campaigns at geodetic observatories in Wettzell, Germany and Onsala, Sweden. Our instrument's long-term stability of 0.5 nm/s2 is the best value for absolute gravimeters reported to date [1]. Our measured gravity value agrees with other state-of-the-art gravimeters on the 10-9 level in g, demonstrating effective control over systematics including wavefront distortions of the Raman beams [2]. By using the juggling technique [3], we are able to perform gravity measurements on two atomic clouds simultaneously. Advantages include the suppression of common mode phase noise, enabling differential phase shift extraction without the need for vibration isolation. We will present the results of our first gravity gradient measurements. [1] Freier, Hauth, Schkolnik, Leykauf, Schilling, Wziontek, Scherneck, Müller and Peters (2016). Mobile quantum gravity sensor with unprecedented stability. Journal of Physics: Conference Series, 8th Symposium on Frequency Standards and Metrology 2015, 723, 12050. [2] Schkolnik, Leykauf, Hauth, Freier and Peters (2015). The effect of wavefront aberrations in atom interferometry. Applied Physics B, 120(2), 311 - 316. [3] Legere and Gibble (1998). Quantum Scattering in a Juggling Atomic Fountain. Physical Review Letters, 81(1), 5780 - 5783.
Intracellular diffusion in the presence of mobile buffers. Application to proton movement in muscle.
Irving, M; Maylie, J; Sizto, N L; Chandler, W K
1990-04-01
Junge and McLaughlin (1987) derived an expression for the apparent diffusion constant of protons in the presence of both mobile and immobile buffers. Their derivation applies only to cases in which the values of pH are considerably greater than the largest pK of the individual buffers, a condition that is not expected to hold in skeletal muscle or many other cell types. Here we show that, if the pH gradients are small, the same expression for the apparent diffusion constant of protons can be derived without such constraints on the values of the pK's. The derivation is general and can be used to estimate the apparent diffusion constant of any substance that diffuses in the presence of both mobile and immobile buffers. The apparent diffusion constant of protons is estimated to be 1-2 x 10(-6) cm2/s at 18 degrees C inside intact frog twitch muscle fibers. It may be smaller inside cut fibers, owing to a reduction in the concentration of mobile myoplasmic buffers, so that in this preparation a pH gradient, if established within a sarcomere following action potential stimulation, could last 10 ms or longer after stimulation ceased.
Sedimentation and mobility of PDCs: a reappraisal of ignimbrites' aspect ratio.
Giordano, Guido; Doronzo, Domenico M
2017-06-30
The aspect ratio of ignimbrites is a commonly used parameter that has been related to the energy of the parent pyroclastic density currents (PDCs). However this parameter, calculated as the ratio between the average thickness and the average lateral extent of ignimbrites, does not capture fundamental differences in pyroclastic flow mobility nor relates to lithofacies variations of the final deposits. We herein introduce the "topological aspect ratio" (ARt) as the ratio of the local deposit thickness (Ht) to the distance between the local site and the maximum runout distance (Lt), where Ht is a proxy for the PDC tendency to deposit, and Lt a proxy for the PDC mobility or its tendency to further transport the pyroclastic material. The positive versus negative spatial gradient d(ARt)/dx along flow paths discriminate zones where PDCs are forced (i.e. where they transport the total energy under the action of mass discharge rate) from zones where they are inertial (i.e. where they transport the total energy under the action of viscous or turbulent fluidization). Though simple to apply, the topological aspect ratio and its spatial gradient are powerful descriptors of the interplay between sedimentation and mobility of PDCs, and of the resulting lithofacies variations.
A multimodal histamine ligand for chromatographic purification of plasmid DNA.
Černigoj, Urh; Vidic, Urška; Barut, Miloš; Podgornik, Aleš; Peterka, Matjaž; Štrancar, Aleš
2013-03-15
To exploit different chromatographic modes for efficient plasmid DNA (pDNA) purification a novel monolithic chromatographic support bearing multimodal histamine (HISA) groups was developed and characterized. Electrostatic charge of HISA groups depends on the pH of the mobile phase, being neutral above pH 7 and becoming positively charged below. As a consequence, HISA groups exhibit predominantly ion-exchange character at low pH values, which decreases with titration of the HISA groups resulting in increased hydrophobicity. This feature enabled separation of supercoiled (sc) pDNA from other plasmid isoforms (and other process related impurities) by adjusting salt or pH gradient. The dynamic binding capacity (DBC) for a 5.1kbp large plasmid at pH 5 was 4.0 mg/ml under low salt binding conditions, remaining relatively high (3.0 mg/ml) even in the presence of 1.0 M NaCl due to the multimodal nature of HISA ligand. Only slightly lower DBC (2.7 mg/ml) was determined under preferentially hydrophobic conditions in 3.0 M (NH(4))(2)SO(4), pH 7.4. Open circular and sc pDNA isoforms were baseline separated in descending (NH(4))(2)SO(4) gradient. Furthermore, an efficient plasmid DNA separation was possible both on analytical as well as on preparative scale by applying the descending pH gradient at a constant concentration (above 3.0 M) of (NH(4))(2)SO(4). Copyright © 2013 Elsevier B.V. All rights reserved.
Monolithic stationary phases with a longitudinal gradient of porosity.
Urban, Jiří; Hájek, Tomáš; Svec, Frantisek
2017-04-01
The duration of the hypercrosslinking reaction has been used to control the extent of small pores formation in polymer-based monolithic stationary phases. Segments of five columns hypercrosslinked for 30-360 min were coupled via zero-volume unions to prepare columns with segmented porosity gradients. The steepness of the porosity gradient affected column efficiency, mass transfer resistance, and separation of both small-molecule alkylbenzenes and high-molar-mass polystyrene standards. In addition, the segmented column with the steepest porosity gradient was prepared as a single column with a continuous porosity gradient. The steepness of porosity gradient in this type column was tuned. Compared to a completely hypercrosslinked column, the column with the shallower gradient produced comparable size-exclusion separation of polystyrene standards but allowed higher column permeability. The completely hypercrosslinked column and the column with porosity gradient were successfully coupled in online two-dimensional liquid chromatography of polymers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Phase correction system for automatic focusing of synthetic aperture radar
Eichel, Paul H.; Ghiglia, Dennis C.; Jakowatz, Jr., Charles V.
1990-01-01
A phase gradient autofocus system for use in synthetic aperture imaging accurately compensates for arbitrary phase errors in each imaged frame by locating highlighted areas and determining the phase disturbance or image spread associated with each of these highlight areas. An estimate of the image spread for each highlighted area in a line in the case of one dimensional processing or in a sector, in the case of two-dimensional processing, is determined. The phase error is determined using phase gradient processing. The phase error is then removed from the uncorrected image and the process is iteratively performed to substantially eliminate phase errors which can degrade the image.
Gwarda, Radosław Ł; Dzido, Tadeusz H
2018-07-13
In our previous papers we have investigated the influence of the mobile phase composition on mechanism of retention, selectivity and efficiency of peptide separation in various high-performance thin-layer chromatography (HPTLC) systems with commercially available silica-based adsorbents. We have also investigated the influence of pH of the mobile phase buffer on migration and separation of peptides in pressurized planar electrochromatography (PPEC). Here we investigate the influence of concentration of ion-pairing additive, and concentration and type of organic modifier of the mobile phase on migration of peptides in PPEC system with octadecyl silica-based adsorbent, and with the same set of the solutes as before. We compare our current results with the results obtained before for similar HPTLC and PPEC systems, and discuss the influence of particular variables on retention, electrophoretic mobility of solutes and electroosmotic flow of the mobile phase. We show, that the final selectivity of peptide separation results from co-influence of all the three factors mentioned. Concentration of organic modifier of the mobile phase, as well as concentration of ion-pairing additive, affect the retention, the electrophoretic mobility, and the electroosmotic flow simultaneously. This makes independent optimization of these factors rather difficult. Anyway PPEC offers much faster separation of peptides with quite different selectivity, in comparison to HPTLC, with similar adsorbents and similar mobile phase composition. However, we also present and discuss the issue of extensive tailing of peptide zones in the PPEC in comparison to similar HPTLC systems. Copyright © 2018 Elsevier B.V. All rights reserved.
Fgf8 morphogen gradient forms by a source-sink mechanism with freely diffusing molecules.
Yu, Shuizi Rachel; Burkhardt, Markus; Nowak, Matthias; Ries, Jonas; Petrásek, Zdenek; Scholpp, Steffen; Schwille, Petra; Brand, Michael
2009-09-24
It is widely accepted that tissue differentiation and morphogenesis in multicellular organisms are regulated by tightly controlled concentration gradients of morphogens. How exactly these gradients are formed, however, remains unclear. Here we show that Fgf8 morphogen gradients in living zebrafish embryos are established and maintained by two essential factors: fast, free diffusion of single molecules away from the source through extracellular space, and a sink function of the receiving cells, regulated by receptor-mediated endocytosis. Evidence is provided by directly examining single molecules of Fgf8 in living tissue by fluorescence correlation spectroscopy, quantifying their local mobility and concentration with high precision. By changing the degree of uptake of Fgf8 into its target cells, we are able to alter the shape of the Fgf8 gradient. Our results demonstrate that a freely diffusing morphogen can set up concentration gradients in a complex multicellular tissue by a simple source-sink mechanism.
Fabrication and microstructures of functional gradient SiBCN–Nb composite by hot pressing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Min, E-mail: lcxsunmin@163.com; Fu, Ruoyu; Chen, Jun
2016-04-15
A functional gradient material with five layers composed of SiBCN ceramic and niobium (Nb) was prepared successfully by hot pressing. The phase composition, morphology features and microstructures were investigated in each layer of the gradient material. The Nb-containing compounds involving NbC, Nb{sub 6}C{sub 5}, Nb{sub 4}C{sub 3}, Nb{sub 5}Si{sub 3} and NbN increase with the volume fraction of Nb increasing in the sub-layer. They are randomly scattered (≤ 25 vol.% Nb), then strip-like, and finally distribute continuously (≥ 75 vol.% Nb). The size of BN(C) and SiC grains in Nb-containing layers is larger than in 100% SiBCN layer due tomore » the loss of the capsule-like structures. No distinct interfaces form in the transition regions indicating the gradual changes in phase composition and microstructures. - Highlights: • A functional gradient SiBCN–Nb material was prepared successfully by hot pressing. • Phase composition, morphology features and microstructures were investigated. • Thermodynamic calculation was used to aid in the phase analysis. • No distinct interfaces form typical of the functional gradient material.« less
Tsonev, Latchezar I; Hirsh, Allen G
2016-10-14
We have previously described a liquid chromatographic (LC) method for uncoupling controlled, wide range pH gradients and simultaneous controlled gradients of a non-buffering solute on ion exchange resins (Hirsh and Tsonev, 2012) [1]. Here we report the application of this two dimensional LC technique to the problem of resolving Human Transferrin (HT) isoforms. This important iron transporting protein should theoretically occur in several thousand glycoforms, but only about a dozen have been reported. Using dual simultaneous independent gradients (DSIGs) of acetonitrile (ACN) and pH on a mixed bed stationary phase (SP) consisting of a mixture of an anion exchange resin and a reversed phase (RP) resin we partially resolve about 60 isoforms. These are likely to be partially refolded glycoforms generated by interaction of HT with the highly hydrophobic RP SP, as well as distinct folded glycoforms. Thus this study should have interesting implications for both glycoform separation and the study of protein folding. Copyright © 2016 Elsevier B.V. All rights reserved.
The Phase Rule in a System Subject to a Pressure Gradient
NASA Astrophysics Data System (ADS)
Podladchikov, Yuri; Connolly, James; Powell, Roger; Aardvark, Alberto
2015-04-01
It can be shown by diligent application of Lagrange's method of undetermined multipliers that the phase rule in a system subject to a pressure gradient is: � + 赑 ≥ ρ. We explore the consequence of this important relationship for natural systems.
Geographic Mobility of Postsecondary Occupational Education Graduates. Phase II.
ERIC Educational Resources Information Center
Winter, Gene M.; Fadale, LaVerna M.
This report of the second phase of a study of the geographic mobility patterns of postsecondary occupational education graduates in New York State provides a further examination of reasons for the mobility of program completers, verifies the general magnitude of the identified mobility trends, and examines the occupational status of program…
Matarashvili, Iza; Shvangiradze, Iamze; Chankvetadze, Lali; Sidamonidze, Shota; Takaishvili, Nino; Farkas, Tivadar; Chankvetadze, Bezhan
2015-12-01
The separation of the stereoisomers of 23 chiral basic agrochemicals was studied on six different polysaccharide-based chiral columns in high-performance liquid chromatography with various polar organic mobile phases. Along with the successful separation of analyte stereoisomers, emphasis was placed on the effect of the chiral selector and mobile phase composition on the elution order of stereoisomers. The interesting phenomenon of reversal of enantiomer/stereoisomer elution order function of the polysaccharide backbone (cellulose or amylose), type of derivative (carbamate or benzoate), nature, and position of the substituent(s) in the phenylcarbamate moiety (methyl or chloro) and the nature of the mobile phase was observed. For several of the analytes containing two chiral centers all four stereoisomers were resolved with at least one chiral selector/mobile phase combination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Haidekker, M A; White, C R; Frangos, J A
2001-10-01
Endothelial cells in blood vessels are exposed to bloodflow and thus fluid shear stress. In arterial bifurcations and stenoses, disturbed flow causes zones of recirculation and stagnation, which are associated with both spatial and temporal gradients of shear stress. Such gradients have been linked to the generation of atherosclerotic plaques. For in-vitro studies of endothelial cell responses, the sudden-expansion flow chamber has been widely used and described. A two-dimensional numerical simulation of the onset phase of flow through the chamber was performed. The wall shear stress action on the bottom plate was computed as a function of time and distance from the sudden expansion. The results showed that depending on the time for the flow to be established, significant temporal gradients occurred close to the second stagnation point of flow. Slowly ramping the flow over 15 s instead of 200 ms reduces the temporal gradients by a factor of 300, while spatial gradients are reduced by 23 percent. Thus, the effects of spatial and temporal gradients can be observed separately. In experiments on endothelial cells, disturbed flow stimulated cell proliferation only when flow onset was sudden. The spatial patterns of proliferation rate match the exposure to temporal gradients. This study provides information on the dynamics of spatial and temporal gradients to which the cells are exposed in a sudden-expansion flow chamber and relates them to changes in the onset phase of flow.
Proton transport by phosphate diffusion--a mechanism of facilitated CO2 transfer
1976-01-01
We have measured CO2 fluxes across phosphate solutions at different carbonic anhydrase concentrations, bicarbonate concentration gradients, phosphate concentrations, and mobilities. Temperature was 22-25 degrees C, the pH of the phosphate solutions was 7.0-7.3. We found that under physiological conditions of pH and pCO2 a facilitated diffusion of CO2 occurs in addition to free diffusion when (a) sufficient carbonic anhydrase is present, and (b) a concentration gradient of HCO3- is established along with a pCO2 gradient, and (c) the phosphate buffer has a mobility comparable to that of bicarbonate. When the phosphate was immobilized by attaching 0.25-mm-long cellulose particles, no facilitation of CO2 diffusion was detectable. A mechanism of facilitated CO2 diffusion in phosphate solutions analogous to that in albumin solutions was proposed on the basis of these findings: bicarbonate diffusion together with a facilitated proton transport by phosphate diffusion. A mathematical model of this mechanism was formulated. The CO2 fluxed predicted by the model agree quantitatively with the experimentally determined fluxes. It is concluded that a highly effective proton transport mechanism acts in solutions of mobile phosphate buffers. By this mechanism; CO2 transfer may be increased up to fivefold and proton transfer may be increased to 10,000-fold. PMID:6619
Baeza-Baeza, J J; Ruiz-Angel, M J; García-Alvarez-Coque, M C
2007-09-07
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC, both modifiers (surfactant and acetonitrile) were observed to decrease or improve the efficiencies in the same percentage, at least in the studied concentration ranges. The study also revealed that the problem of achieving smaller efficiencies in this chromatographic mode, compared to hydro-organic RPLC, is not only related to the presence of surfactant covering the stationary phase, but also to the smaller concentration of organic solvent in the mobile phase.
Teichtmeister, S.; Aldakheel, F.
2016-01-01
This work outlines a novel variational-based theory for the phase-field modelling of ductile fracture in elastic–plastic solids undergoing large strains. The phase-field approach regularizes sharp crack surfaces within a pure continuum setting by a specific gradient damage modelling. It is linked to a formulation of gradient plasticity at finite strains. The framework includes two independent length scales which regularize both the plastic response as well as the crack discontinuities. This ensures that the damage zones of ductile fracture are inside of plastic zones, and guarantees on the computational side a mesh objectivity in post-critical ranges. PMID:27002069
Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS.
Berg, Thomas; Lundanes, Elsa; Christophersen, Asbjørg S; Strand, Dag Helge
2009-02-01
A fast and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of opiates (morphine, codeine, 6-monoacetylmorphine (6-MAM), pholcodine, oxycodone, ethylmorphine), cocaine and benzoylecgonine in urine has been developed and validated. Sample preparation was performed by solid phase extraction (SPE) on a mixed mode cation exchange (MCX) cartridge. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing of all analytes at the column inlet at gradient start, a basic mobile phase consisting of 5mM ammonium bicarbonate, pH 10.2, and methanol (MeOH) was chosen. Positive electrospray ionization (ESI(+)) MS/MS detection was performed with a minimum of two multiple reaction monitoring (MRM) transitions for each analyte. Deuterium labelled-internal standards were used for six of the analytes. Between-assay retention time repeatabilities (n=10 series, 225 injections in total) had relative standard deviation (RSD) values within 0.1-0.6%. Limit of detection (LOD) and limit of quantification (LOQ) values were in the range 0.003-0.05 microM (0.001-0.02 microg/mL) and 0.01-0.16 microM (0.003-0.06 microg/mL), respectively. The RSD values of the between-assay repeatabilities of concentrations were
Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro
2017-01-20
Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω 1 ), the planet axis (ω 2 ) and the satellite axis (the central axis of the column) (ω 3 ) according to the following formula: ω 1 =ω 2 +ω 3 . Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3: 2: 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω 1 , ω 2 , ω 3 )=(300, 150, 150rpm), and (1:4:5, v/v) for the upper mobile phase at (300:100:200rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω 2 and ω 3 under the constant revolution speed at ω 1 =300rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω 2 and ω 3 , while with the upper mobile phase these two values were sensitively varied according to the different combination of ω 2 and ω 3 . For example, when ω 2 =147 or 200rpm is used, no stationary phase was retained in the coiled column while ω 2 =150rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω 1 , ω 2 , ω 3 )=(300, 300, 0rpm) or (300, 0, 300rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300rpm) with the upper mobile phase. At lower rotation speed of ω 1 =300rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω 3 ) than by the planetary motion (ω 2 ), or ω 3 >ω 2 . The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n-hexane/ethyl acetate/1-butanol/methanol/water system at different volume ratios. In the satellite motion at (ω 1 , ω 2 , ω 3 )=(300, 150, 150rpm), almost constant stationary phase retention was obtained with the lower mobile phase regardless of the hydrophobicity of the solvent system whereas the stationary phase retention varied according to the volume ratio of the two-phase solvent system for the upper mobile phase. However, stable stationary phase retention was observed with either phase used as the mobile phase. In order to analyze the acceleration acting on the coiled column, an acceleration sensor was set on the column holder by displacing the multilayer column. The combination of the rotation speeds at (300, 100, 200rpm) showed double loops in the acceleration track, whereas (300, 150, 150rpm) showed a single loop, and all other combinations showed, complex tracks. The overall results indicate that the satellite motion is seriously affected by the combination of rotation speeds and the hydrophobicity of the two-phase solvent system when the upper phase was used as the mobile phase for separation. Copyright © 2016 Elsevier B.V. All rights reserved.
Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro
2016-01-01
Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3) according to the following formula: ω1 = ω2 + ω3. Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω1, ω2, ω3) = (300, 150, 150 rpm), and (1 : 4 : 5, v/v) for the upper mobile phase at (300 : 100 : 200 rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω2 and ω3 under the constant revolution speed at ω1 = 300 rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω2 and ω3, while with the upper mobile phase these two values were sensitively varied according to the different combination of ω2 and ω3. For example, when ω2 = 147 or 200 rpm is used, no stationary phase was retained in the coiled column while ω2 = 150 rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω1, ω2, ω3) = (300, 300, 0 rpm) or (300, 0, 300 rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300 rpm) with the upper mobile phase. At lower rotation speed of ω1 = 300 rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω3) than by the planetary motion (ω2), or ω3 > ω2. The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n-hexane/ethyl acetate/1-butanol/methanol/water system at different volume ratios. In the satellite motion at (ω1, ω2, ω3) = (300, 150, 150 rpm), almost constant stationary phase retention was obtained with the lower mobile phase regardless of the hydrophobicity of the solvent system whereas the stationary phase retention varied according to the volume ratio of the two-phase solvent system for the upper mobile phase. However, stable stationary phase retention was observed with either phase used as the mobile phase. In order to analyze the acceleration acting on the coiled column, an acceleration sensor was set on the column holder by displacing the multilayer column. The combination of the rotation speeds at (300, 100, 200 rpm) showed double loops in the acceleration track, whereas (300, 150, 150 rpm) showed a single loop, and all other combinations showed, complex tracks. The overall results indicate that the satellite motion is seriously affected by the combination of rotation speeds and the hydrophobicity of the two-phase solvent system when the upper phase was used as the mobile phase for separation. PMID:28040269
Maire, Julien; Joubert, Antoine; Kaifas, Delphine; Invernizzi, Thomas; Marduel, Julien; Colombano, Stéfan; Cazaux, David; Marion, Cédric; Klein, Pierre-Yves; Dumestre, Alain; Fatin-Rouge, Nicolas
2018-01-15
Immiscible mobilization and foam flushing were assessed as low surfactant consuming technologies, for the enhanced recovery of dense non-aqueous phase liquid (DNAPL) residual at a site contaminated by heavy chlorinated compounds. Preliminary experiments in well-controlled conditions demonstrated the phenomena involved in these remediation technologies and their limitations. Furthermore, we characterized the technologies according to by their surfactant consumption (per kg of DNAPL recovered) and the final DNAPL saturation reached. Surfactant foam flushing (SFF) produced lower DNAPL saturation than immiscible mobilization, thanks to its higher viscosity. However, its efficiency is strongly correlated to the pressure gradient (▽P) used during injection, and that is limited by risks of soil fracturing. The two technologies were tested in field cells (10m×10m×10m) delimited by cement/bentonite walls anchored in the clayey substratum. The deepest soil layer was the most contaminated. It was composed of silt-sandy soil and had an average hydraulic conductivity of 10 -4 ms -1 . Field results show that we should now model flushing fluid propagation to design efficient set-ups for recovering the displaced DNAPL. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volkov, M V; Garanin, S G; Dolgopolov, Yu V
2014-11-30
A seven-channel fibre laser system operated by the master oscillator – multichannel power amplifier scheme is the phase locked using a stochastic parallel gradient algorithm. The phase modulators on lithium niobate crystals are controlled by a multichannel electronic unit with the microcontroller processing signals in real time. The dynamic phase locking of the laser system with the bandwidth of 14 kHz is demonstrated, the time of phasing is 3 – 4 ms. (fibre and integrated-optical structures)
Effects of elevated temperature and mobile phase composition on a novel C18 silica column.
Lippert, J Andreas; Johnson, Todd M; Lloyd, Jarem B; Smith, Jared P; Johnson, Bryce T; Furlow, Jason; Proctor, Angela; Marin, Stephanie J
2007-05-01
A novel polydentate C18 silica column was evaluated at an elevated temperature under acidic, basic, and neutral mobile phase conditions using ACN and methanol as the mobile phase organic modifier. The temperature range was 40-200 degrees C. The mobile phase compositions were from 0 to 80% organic-aqueous v/v and the mobile phase pH levels were between 2 and 12. The maximum operating temperature of the column was affected by the amount and type of organic modifier used in the mobile phase. Under neutral conditions, the column showed good column thermal stability at temperatures ranging between 120 and 200 degrees C in methanol-water and ACN-water solvent systems. At pH 2 and 3, the column performed well up to about 160 degrees C at two fixed ACN-buffer compositions. Under basic conditions at elevated temperatures, the column material deteriorated more quickly, but still remained stable up to 100 degrees C at pH 9 and 60 degrees C at pH 10. The results of this study indicate that this novel C18 silica-based column represents a significant advancement in RPLC column technology with enhanced thermal and pH stability when compared to traditional bonded phase silica columns.
[Influence of mobile phase composition on chiral separation of organic selenium racemates].
Han, Xiao-qian; Qi, Bang-feng; Dun, Hui-juan; Zhu, Xin-yi; Na, Peng-jun; Jiang, Sheng-xiang; Chen, Li-ren
2002-05-01
The chiral separation of some chiral compounds with similar structure on the cellulose tris (3,5-dimethylphenylcarbamate) chiral stationary phase prepared by us was obtained. Ternary mobile phases influencing chiral recognition were investigated. A mode of interaction between the structural character of samples and chiral stationary phase is discussed. The results indicated that the retention and chiral separation of the analytes had a bigger change with minute addition of alcohols or acetonitrile as modifier in n-hexane/2-propanol (80/20, volume ratio) binary mobile phase.
Xie, Chenchen; Gao, Xiang; Luo, Yong; Pang, Yueshan; Li, Man
2016-10-01
Stromal cell-derived factor-1α(SDF-1α) plays a crucial role in regulating the mobilization, migration and homing of endothelial progenitor cells(EPCs). Electroacupuncture(EA), a modern version of Traditional Chinese Medicine, can improve neurological recovery and angiogenesis in cerebral ischemic area. This study aimed to investigate the effects of electroacupuncture(EA) on the mobilization and migration of bone marrow EPCs and neurological functional recovery in rats model after focal cerebral ischemia/reperfusion and the potentially involved mechanisms. Sprague-Dawley rats received filament occlusion of the right middle cerebral artery for 2h followed by reperfusion for 12h, 1d, 2d, 3d, 7d respectively. Rats were randomly divided into sham group, model group and EA group. After 2h of the reperfusion, EA was given at the "Baihui" (GV 20)/Siguan ("Hegu" (LI 4)/"Taichong" (LR 3)) acupoints in the EA group. Modified neurological severity score (mNSS) was used to assess the neurological functional recovery. EPCs number and SDF-1α level in bone marrow(BM) and peripheral blood(PB) were detected by using fluorescence-activated cell sorting (FACS) analysis and quantitative real time polymerase chain reaction (qRT-PCR) respectively. An mNSS test showed that EA treatment significantly improved the neurological functional outcome. EPCs number in PB and BM were obviously increased in the EA group. After cerebral ischemia, the SDF-1α level was decreased in BM while it was increased in PB, which implied a gradient of SDF-1α among BM and PB after ischemia. It suggested that the forming of SDF-1α concentration gradient can induce the mobilization and homing of EPCs. Eletroacupuncture as a treatment can accelerate and increase the forming of SDF-1α concentration gradient to further induce the mobilization of EPCs and angiogenesis in ischemic brain and improve the neurological function recovery. Copyright © 2016 Elsevier B.V. All rights reserved.
DOT National Transportation Integrated Search
2015-01-01
As mobile technology becomes widely available and affordable, transportation agencies can use this : technology to streamline operations involved within project inspection. This research, conducted in two : phases, identified opportunities for proces...
Lv, Jin-Li; Yang, Biao; Li, Meng-Xuan; Meng, Zhao-Qing; Ma, Shi-Ping; Wang, Zhen-Zhong; Ding, Gang; Huang, Wen-Zhe; Xiao, Wei
2017-03-01
To study Ginkgo biloba leaves in different producing area, we establish an HPLC method for the simultaneously determination of seven flavonoids glycosides and four biflavonoids in G. biloba leaves. The analysis was performed on an Agilent ZORBAX SB-C₁₈ column(4.6 mm×250 mm, 5 μm) wich acetonitrile, and 0.4% phosphoric acid as mobile phase at flow rate of 1 mL•min⁻¹ in a gradient edution, and the detection was carried out at 254 nm.The calibration curves of the seven flavonoids glycosides and four biflavonoids had a good linearitiy with good recoveries. The established HPLC method is simple, rapid, accurate, reliable, and sensitive, and can be applied to the identification and quality control of G. biloba leaves. Copyright© by the Chinese Pharmaceutical Association.
[HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].
Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan
2014-11-01
To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.
Qin, Feng; Huang, Jun; Qiu, Xinjian; Hu, Sihang; Huang, Xi
2011-01-01
A simple, sensitive, and reliable ultra-performance liquid chromatography (UPLC) method has been developed for simultaneous determination of 22 major constituents in modified xiaoyao san (MXS), a multiherbal formula. The chromatographic separation was performed on an ACQUITY UPLC BEH C18 column (150 x 2.1 mm, 1.7 microm, particle size), with an aqueous 0.5% acetic acid and acetonitrile mobile phase gradient. The method was validated for linearity (r2 >0.9937), intraday and interday precision (RSD <8.51%), recovery (91.18-107.73%), LOD (0.02-4.17 ng/mL), and LOQ (0.05-12.50 ng/mL). The established method was successfully applied to quantify the 22 marker compounds in MXS, which provided a useful basis of overall evaluation of the quality of MXS.
Simultaneous determination of three anticonvulsants using hydrophilic interaction LC-MS.
Oertel, Reinhard; Arenz, Norman; Pietsch, Jörg; Kirch, Wilhelm
2009-01-01
A specific and automated method was developed to quantify the anticonvulsants gabapentin, pregabalin and vigabatrin simultaneously in human serum. Samples were prepared with a protein precipitation. The hydrophilic interaction chromatography (HILIC) with a mobile phase gradient was used to divide off ions of the matrix and for separation of the analytes. Four different HILIC-columns and two different column temperatures were tested. The Tosoh-Amid column gave the best results: single small peaks. The anticonvulsants were detected in the multiple reaction monitoring mode (MRM) with ESI-MS-MS. Using a volume of 100 microL biological sample the lowest point of the standard curve, i.e. the lower LOQs were 312 ng/mL. The described HILIC-MS-MS method is suitable for therapeutic drug monitoring and for clinical and pharmcokinetical investigations of the anticonvulsives.
Tylová, Tereza; Kolařík, Miroslav; Olšovská, Jana
2011-07-01
A new simple ultra-high-performance liquid chromatography method with diode array detection (UHPLC-DAD) was developed for chemical fingerprinting analysis of extracellular metabolites in fermentation broth of Geosmithia spp. The SPE method employing Oasis MCX strong cation-exchange mixed-mode polymeric sorbent was chosen for extraction of the metabolites. The analyses were performed on an Acquity UPLC BEH C18 column (100 × 2.1 mm i.d.; particle size, 1.7 μm; Waters) using a gradient elution program with an aqueous solution of trifluoroacetic acid and acetonitrile as the mobile phase. The applicability of the method was proved by analysis of 38 strains produced by different species and isolated from different sources (hosts). The results revealed the correlation of obtained UHPLC-DAD fingerprints with taxonomical identity.
NASA Astrophysics Data System (ADS)
Zhang, S. L.; Zhang, J.; Wang, Z. G.; Wang, Y. Z.; Liang, S. T.; Liu, C.; Wang, Z.
2017-08-01
Several samples collected from lakes, rivers and reservoirs in Haihe river basin of China were analyzed for 8 sulfonamide antibiotics by using solid-phase extraction and liquid chromatography with tandem mass spectrometry (HPLC-MS/MS). All water samples were enriched with HLB extraction cartridges. The antibiotics were separated by gradient elution with methanol as the mobile phase adding 0.1% formic acid. The eluate was then analyzed by the mode of multiple reaction monitoring (MRM). The limits of detection (LOD) and quantification (LOQ) were 0.4-1.0 ng/L and 1.0-3.0 ng/L respectively. The method was used for the analysis of 13 samples from Haihe river basin in China. The results showed that sulfamethoxazole was present in all water samples with maximum concentration of 107.59 ng/L. Sulfadiazine was also frequently detected, concentrations ranging from 2.81 ng/L to 85.35 ng/L. Other sulfonamide antibiotics were not detected in most water samples, especially for those samples from drinking water resources.
[Application of fingerprint chromatogram in quality control of Shen-Mai injection].
Shi, Xian-zhe; Yang, Jun; Zhao, Chun-xia; Xiong, Jian-hui; Xu, Guo-wang
2002-07-01
The theory and practice of traditional Chinese medicine require some comprehensive methods to assess quality of the Chinese herbal medication. Fingerprint chromatogram is one of the feasible approaches to evaluate the quality of Chinese herbal medication. So the fingerprint chromatogram of Shen-Mai injection was established by using reversed-phase high performance liquid chromatography. The chromatographic conditions were as follows: a Hypersil C18 column was used; the mobile phase was composed of water (A) and acetontrile (B) with linear gradient elution (0-50 min, 5%-95% B, volume fraction); the flow rate was 1.0 mL/min and the UV absorbance detection was set at 202 nm. The peak-area ratios of twenty-three fingerprint peaks and internal standard (diphenyl) were taken as the criteria for quality control. The quality differences in various batches and various manufacturers of Shen-Mai injections were investigated by projection discriminance based on principal component analysis. The results show the method developed is convenient, reliable and applicable for the quality control analysis of Shen-Mai injection.
Zhuang, Yan-Shuang; Cai, Hao; Liu, Xiao; Cai, Bao-Chang
2012-01-01
Reversed phase high performance liquid chromatography with diode array detector was employed for simultaneous determination of five main index components and specific chromatograms analysis in Xiaochaihu granules with a linear gradient elution of acetonitrile-water (containing 0.1% phosphoric acid) as mobile phase. The results showed that five main index components (baicalin, baicalein, wogonoside, wogonin, enoxolone) were separated well under the analytical condition. The linear ranges of five components were 0.518 - 16.576, 0.069 - 2.197, 0.167 - 5.333, 0.009 - 0.297 and 0.006 - 0.270 mg x g(-1), respectively. The correlation coefficients were 0.999 9, and the average recoveries ranged from 95% to 105%. Twelve common peaks were selected as the specific chromatograms of Xiaochaihu granules with baicalin as the reference peak. There were good similarities between the reference and the ten batches of samples. The similarity coefficients were no less than 0.9. The analytical method established is highly sensitive with strong specificity and it can be used efficiently in the quality control of Xiaochaihu granules.
[HPLC Fingerprint of QingGuangAn and Determination of the Main Components].
Wang, Min; Shen, Bing-bing; Luo, Juan; Chen, Yang; Yang, Yu-pei; Chen, Sheng-huang
2015-10-01
To establish an HPLC fingerprint of ethanol extract of QingGuangAn, and to determine the contents of paeoniflorin and calycosin-7-glucosid. HPLC analysis was performed on an Agilent 1260 Infinity LC system and carried out at 35 degrees C on a column of GRACE Alltima C18 (250 mm x 4.6 mm, 5 μm). A binary gradient elution system was composed of acetonitrile (phase A) and water solution (phase B). Detection was performed at the wavelength of 254 nm, the mobile flow rate was 0.8 mL/min. A matrix including 20 variations (characteristic peaks area) and 10 samples was constructed for similarity evaluation. The results showed that the collected samples had a good similarity. A specificity fingerprint was produced and 20 characteristic peaks were designated. The content of paeoniflorin and calycosin-7-glucosid was 0.368 and 0.049 mg/g, respectively. It is a reliable, available and quick method for quality control of QingGuangAn,which provides some reference for the comparison of different extracting methods of QingGuangAn and the differences of pharmacodynamic.
Stipcovich, Tea; Barbero, Gerardo F; Ferreiro-González, Marta; Palma, Miguel; Barroso, Carmelo G
2018-01-15
A rapid high-performance liquid chromatography method with a C18 reverse-phase fused-core column has been developed for the determination and quantification of the main capsaicinoids (nornordihydrocapsaicin, nordihydrocapsaicin, capsaicin, dihydrocapsaicin, homocapsaicin and homodihydrocapsaicin) present in Naga Jolokia peppers. A fused-core Kinetex™ C18 column (50×2.1mm i.d.; 2.6μm) was used for the analysis. The chromatographic separation was obtained with a gradient method in which the mobile phase was water (0.1% acetic acid) as solvent A and acetonitrile (0.1% acetic acid) as solvent B. The separation of all compounds was achieved in less than 3min with a total analysis time (sample-to-sample) of 10min. The robustness of the method was evaluated. The method showed excellent repeatability and intermediate precision expressed as coefficient of variance of less than 2%. The developed method was employed for the quantification of the major capsaicinoids present in different peppers and commercial products containing chilli peppers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Han, Stanislaw; Karlowicz-Bodalska, Katarzyna; Ozimek, Lukasz
2013-01-01
In the course of research and development of a new pharmaceutical formulation of azelaic acid in the liposomal form, we developed a rapid and accurate method for the detection of impurities using high-performance liquid chromatography. A chromatographic column from Merck (Purospher Star RP C18, 250–4 mm (5 μm) was used in the assay, and the mobile phase gradient consisted of three phases: A—methanol : water (5 : 95) + 1.5% (v/v) acetic acid; B—water : methanol (5 : 95) + 1.5% (v/v) acetic acid; and C—chloroform. Detection of the impurities and the active substance was performed by an evaporative light-scattering detector. The method was validated for selectivity, system precision, method precision, limit of detection, and response rates. The proposed method can be used to detect impurities in the liposomal formulation of azelaic acid. The method enables separation of azelaic acid from the identified and unidentified impurities and from the excipients used in the drug form. PMID:24228008
Li, Jin; Zhang, Qiu-Hong; He, Jun; Liu, Er-wei; Gao, Xiu-mei; Chang, Yan-xu
2015-01-01
An improved LC-MS/MS method was developed for simultaneous determination of eleven bioactive constituents of Radix Angelicae Pubescentis and its related preparations. It was the first report on the quantification of bioactive constituents in different preparations of Radix Angelicae Pubescentis by LC-MS/MS analytical method. These samples were separated with an Agilent Zorbax Extend reversed-phase C18 column (1.8 μm, 4.6 × 100 mm) by linear gradient elution using aqueous ammonium acetate and acetonitrile as mobile phase. The flow rate was 0.3 mL min−1. The eleven bioactive constituents showed good regression (R > 0.990) within test ranges and the recoveries were in the range of 87.1–110%. The limit of detections and quantifications for most of the major constituents were less than 0.5 and 1.0 ng mL−1, respectively. All results indicated that the developed method could be readily utilized as a suitable quality control method for Radix Angelicae Pubescentis and related preparations. PMID:26078992
Reddy, G V Ram; Kumar, A Praveen; Reddy, B Venkateswara; Sreeramulu, J
2009-10-01
Anhydro-simvastatin and simvastatin dimer are the two main impurities in the fermentation broth as well as in the final product of simvastatin, which is a hypolipidemic drug. An unknown impurity with m/z 451 for [(M + H)(+)] was detected in the analysis of final simvastatin drug sample. By using reverse phase high performance liquid chromatography (HPLC)-mass spectrometry (MS) and MS/MS spectra, the unknown impurity was detected and identified. Separation was achieved on ACE-5 C18 (150 x 4.6 mm, 3 microm column) at the flow rate of 1.2 ml min(-1) applying gradient elution of mobile phase A consisting of Milli-Q water of pH 3.0 with formic acid and B consisting of acetonitrile. MS/MS spectrum of the unknown impurity was obtained using HPLC-MS equipped with positive electrosoray ionization (ESI). The unknown impurity is named as 7-[7-(2,2-dimethyl-butyryloxy)-2,6-dimethyl-1,2,6,7,8,8a-hexahydro-naphthalen-1 -yl]-3-hydroxy-5-hydroxymethyl-heptanoic acid.
Han, Stanislaw; Karlowicz-Bodalska, Katarzyna; Szura, Dorota; Ozimek, Lukasz; Musial, Witold
2013-01-01
In the course of research and development of a new pharmaceutical formulation of azelaic acid in the liposomal form, we developed a rapid and accurate method for the detection of impurities using high-performance liquid chromatography. A chromatographic column from Merck (Purospher Star RP C18, 250-4 mm (5 μm) was used in the assay, and the mobile phase gradient consisted of three phases: A--methanol : water (5 : 95) + 1.5% (v/v) acetic acid; B--water : methanol (5 : 95) + 1.5% (v/v) acetic acid; and C--chloroform. Detection of the impurities and the active substance was performed by an evaporative light-scattering detector. The method was validated for selectivity, system precision, method precision, limit of detection, and response rates. The proposed method can be used to detect impurities in the liposomal formulation of azelaic acid. The method enables separation of azelaic acid from the identified and unidentified impurities and from the excipients used in the drug form.
Ultra-Performance Liquid Chromatographic Determination of Tocopherols and Retinol in Human Plasma
Bell, Edward C.; John, Mathew; Hughes, Rodney J.; Pham, Thu
2014-01-01
A rapid, selective and sensitive ultra-performance liquid chromatography method has been developed for the detection and quantification of tocopherols and retinol in human plasma. Alpha-tocopherol, gamma-tocopherol and retinol are assayed using fluorescence detection. Excitation/emission wavelengths are 295/330 nm and 325/470 nm for the analysis of both tocopherols and retinol, respectively. Retinol acetate is employed as the internal standard. The reversed-phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds is achieved using a bridged ethyl hybrid C18 column. The retention times for retinol, retinol acetate, gamma-tocopherol and alpha-tocopherol are 1.6, 1.8, 3.9 and 4.3 min, respectively. The limits of quantification for retinol, gamma-tocopherol and alpha-tocopherol were 0.02, 0.02 and 0.1 µg/mL, respectively. The assay method is suitable for the analysis of tocopherols and retinol in human plasma. The method may be applied following the ingestion of foods fortified with these fat-soluble vitamins. PMID:24170122
Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A
1990-01-01
A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.
Williams, Paul N; Zhang, Hao; Davison, William; Meharg, Andrew A; Hossain, Mahmud; Norton, Gareth J; Brammer, Hugh; Islam, M Rafiqul
2011-07-15
Agroecological zones within Bangladesh with low levels of arsenic in groundwater and soils produce rice that is high in arsenic with respect to other producing regions of the globe. Little is known about arsenic cycling in these soils and the labile fractions relevant for plant uptake when flooded. Soil porewater dynamics of field soils (n = 39) were recreated under standardized laboratory conditions to investigate the mobility and interplay of arsenic, Fe, Si, C, and other elements, in relation to rice grain element composition, using the dynamic sampling technique diffusive gradients in thin films (DGT). Based on a simple model using only labile DGT measured arsenic and dissolved organic carbon (DOC), concentrations of arsenic in Aman (Monsoon season) rice grain were predicted reliably. DOC was the strongest determinant of arsenic solid-solution phase partitioning, while arsenic release to the soil porewater was shown to be decoupled from that of Fe. This study demonstrates the dual importance of organic matter (OM), in terms of enhancing arsenic release from soils, while reducing bioavailability by sequestering arsenic in solution.
Yekkala, Raja Satyanarayana; Vandenwayenberg, Stephanie; Hoogmartens, Jos; Adams, Erwin
2006-11-17
A gradient LC method for the determination of related substances in nelfinavir mesilate (NFVM) has been recently published in the International Pharmacopoeia. The method uses a base deactivated reversed phase C18 column (25 cm x 4.6 mm I.D.), 5 microm kept at a temperature of 35 degrees C. The mobile phases consist of acetonitrile, methanol, phosphate buffer pH 3.4 and water. The flow rate is 1.0 ml/min. UV detection is performed at 225 nm. A system suitability test (SST) is described to govern the quality of the separation. The separation towards NFVM components was investigated on 18 C18 columns and correlation was made with the column classification system developed in our laboratory. The method was evaluated using a Hypersil BDS C18 column (25 cm x 4.6 mm I.D.), 5 microm. A two level fractional factorial design was applied to examine the robustness of the method. The method shows good selectivity, precision, linearity and sensitivity. Seven commercial samples were examined using this method.
Malintan, Nancy T; Mohd, Mustafa Ali
2006-09-15
An analytical HPLC method for the simultaneous determination of eight sulfonamides in swine wastewater was developed. The samples were collected from three states in Malaysia. Sample clean up was carried out by employing solid-phase extraction using a 60 mg Oasis HLB (Waters) cartridge with 3 ml reservoir. The HPLC column used was Supelcosil C18 (250 mm x 4.6mm I.D.) and elution was carried out using gradient mode. The mobile phases used were acetonitrile and 0.5% acetic acid in purified water. Antibiotics were detected using UV absorbance at 272 nm. Recoveries obtained for sulphanilamide ranged from 31.9+/-5.1% to 36.2+/-1.0%, while recoveries for other sulfa drugs studied were from 91.9+/-5.0% to 106.0+/-1.1%. The limit of quantitation (LOQ) for sulfamerazine, sulfamethazine and sulfamethoxypyridazine was 7.5 ng/L, while the LOQ for the other studied antibiotics was 5.0 ng/L. The method was used to analyse sulfonamides in wastewater collected from selected Malaysian swine facilities.
MobileSat (R): A characteristically Australian MSS
NASA Technical Reports Server (NTRS)
Wagg, Michael; Jansen, Michael
1995-01-01
Optus launched its mobile satellite telephone service MobileSat in August 1994. This provided Australia and its neighboring waters with nation-wide mobile telephone coverage and still is the world's only domestic mobile satellite telephone system. This paper provides details of Optus' experience in developing and launching the MobileSat service, including (1) a retrospective of the issues that have waxed and waned in importance during the development and implementation phases, and (2) the strategy for future activities based on the experience gained in the development phase.
NASA Astrophysics Data System (ADS)
Laufek, František; Veselovsky, František; Drábek, Milan; Kříbek, Bohdan; Klementová, Mariana
2017-04-01
The formation of sulfides, selenides and chlorides was experimentally studied at 800 or 900°C in the presence of sal ammoniac in a sealed silica glass tube. Synthetic PbS, PbSe, SnS, GeS, SnGeS2, PbSnS3, SnS and Sb2S3 or natural uraninite were used as a starting charge. Depending on the chemical composition of the sulfide/selenide charge, galena, unnamed SnGeS3 phase, herzenbergite, berndite, ottenmannite, stibnite and unnamed SnSb2S4 and Sn2Sb3S6 phases were identified in sublimates, together with cotunnite and an unnamed (NH4)2SnCl6 phase. When natural uraninite in a mixture with sal ammoniac was used as a charge, the reaction product comprised abundant cotunnite and minor challacolloite due to volatilization of radiogenic lead. When sulfur was introduced to the charge with uraninite and sal ammoniac, galena was found in reaction products. The results of our experiments revealed that if sulfide or selenide phases and NH4Cl are placed in a thermal gradient, it is possible to accelerate their mobility through a process of hydrogen chloride vapor transport. Within the transport process, new solid products are either isochemical or non-isochemical. The isochemical composition of resulting phases with charge probably represents simple sublimation of the original solid phase in form of self-vapor. The non-isochemical phases are probably formed due to combination of sublimation and condensation of various gas components including gaseous HCl. The valency change of metals (e.g. Sn2+ to Sn3+) in several reaction products indicates redox reactions in the gas mixture or during the solidification of resulting products. The role of ammoniac is not clear; however, formation of unnamed (NH4)2SnCl6 compound identified in one of our experiment, indicate possible formation of ammonium complexes. In contrast to experiments where sulfides or selenides were used as a part of charge, mobility of uraninite was not proved under experimental conditions employed. It is consistent with an absence of uranium minerals in products of self-burning. The product of uraninite thermal decomposition was predominantly lead chloride (cotunnite) resulting from the release of radiogenic lead from uraninite structure. However, when sulfur was added to the charge, skeletal crystals of galena were found in the reaction products. Acknowledgments: This study was carried out within the Czech Science Foundation grant project "A model of mobilization and geochemical cycles of potentially hazardous elements and organic compounds in burnt coal heaps" (GACR 15-11674S panel P210).
High-efficiency polarization conversion phase gradient metasurface for wideband anomalous reflection
NASA Astrophysics Data System (ADS)
Zhang, Jiameng; Yang, Lan; Li, Linpeng; Zhang, Tong; Li, Haihong; Wang, Qingmin; Hao, Yanan; Lei, Ming; Bi, Ke
2017-07-01
An ultra-wideband polarization conversion metasurface based on S-shaped metallic structure is designed and prepared. The simulation results show that the polarization conversion bandwidth is 14 GHz for linearly polarized normally incident electromagnetic waves and the cross-polarized reflectance is more than 99% in the range of 10.3 GHz-20.5 GHz. On the premise of high reflection efficiency, the reflective phase can be regulated by changing the geometrical parameter of the S-shaped metallic structure. A phase gradient metasurface composed of six periodically arrayed S-shaped unit cells is proposed and further demonstrated both numerically and experimentally. The specular cross-polarization reflection of the phase gradient metasurface is below -10 dB, which shows a good performance on manipulating the direction of the reflected electromagnetic waves.
Optimized distortion correction technique for echo planar imaging.
Chen , N K; Wyrwicz, A M
2001-03-01
A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effectively remove geometric distortions in subsequent EPI scans. The proposed EPI distortion correction technique has been shown to be effective in removing distortions due to gradient waveform imperfections and phase gradient-induced eddy current effects. In addition, this new method retains advantages of the earlier method, such as simultaneous correction of different off-resonance factors without use of a complicated phase unwrapping procedure. The effectiveness of this technique is illustrated with EPI studies on phantoms and animal subjects. Implementation to different versions of EPI sequences is also described. Magn Reson Med 45:525-528, 2001. Copyright 2001 Wiley-Liss, Inc.
Albrecht, Sandra S.; Gordon-Larsen, Penny
2014-01-01
Background Despite comparatively lower socioeconomic status (SES), immigrants tend to have lower body weight and weaker SES gradients relative to U.S.-born individuals. Yet, it is unknown how changes in SES over the life-course relate to body weight in immigrants versus US-born individuals. Methods We used longitudinal data from a nationally-representative, diverse sample of 13701 adolescents followed into adulthood to investigate whether associations between SES mobility categories (educational attainment reported by individuals as adults and by their parents during adolescence) and body mass index (BMI) measured in adulthood varied by immigrant generation. Weighted multivariable linear regression models were adjusted for age, sex, race/ethnicity, and immigrant generation. Results Among first generation immigrants, although parental education was not associated with adult BMI, an immigrant’s own education attainment was inversely associated with BMI (β=−2.6 kg/m2; standard error (SE)=0.9, p<0.01). In addition, upward educational mobility was associated with lower adult mean BMI than remaining low SES (β= −2.5 kg/m2; SE=1.2, p<0.05). In contrast, among U.S.-born respondents, college education in adulthood did not attenuate the negative association between parental education and adult BMI. Although an SES gradient emerged in adulthood for immigrants, remaining low SES from adolescence to adulthood was not associated with loss of health advantage relative to U.S.-born respondents of U.S.-born parents of similar SES. Conclusion Immigrants were able to translate higher SES in adulthood into a lower adult mean BMI regardless of childhood SES, whereas the consequences of lower childhood SES had a longer reach even among the upwardly mobile U.S.-born. PMID:24847088
Han, Shu-ying; Liang, Chao; Zou, Kuan; Qiao, Jun-qin; Lian, Hong-zhen; Ge, Xin
2012-11-15
The variation in mobile phase pH and ionizable solute dissociation constant (pK(a)) with the change of organic modifier fraction in hydroorganic mobile phase has seemingly been a troublesome problem in studies and applications of reversed phase high performance liquid chromatography (RP-HPLC). Most of the early studies regarding the RP-HPLC of acid-base compounds have to measure the actual pH of the mixed mobile phase rigorously, sometimes bringing difficulties in the practices of liquid chromatographic separation. In this paper, the effect of this variation on the apparent n-octanol/water partition coefficient (K(ow)″) and the related quantitative structure-retention relationship (QSRR) of logK(ow)″ vs. logk(w), the logarithm of retention factor of analytes in neat aqueous mobile phases, was investigated for weakly acidic compounds. This QSRR is commonly used as a classical method for K(ow) measurement by RP-HPLC. The theoretical and experimental derivation revealed that the variation in mobile phase pH and solute pK(a) will not affect the QSRRs of acidic compounds. This conclusion is proved to be suitable for various types of ion-suppressors, i.e., strong acid (perchloric acid), weak acid (acetic acid) and buffer salt (potassium dihydrogen phosphate/phosphoric acid, PBS). The QSRRs of logK(ow)″ vs. logk(w) were modeled by 11 substituted benzoic acids using different types of ion-suppressors in a binary methanol-water mobile phase to confirm our deduction. Although different types of ion-suppressor all can be used as mobile phase pH modifiers, the QSRR model obtained by using perchloric acid as the ion-suppressor was found to have the best result, and the slightly inferior QSRRs were obtained by using acetic acid or PBS as the ion-suppressor. Copyright © 2012 Elsevier B.V. All rights reserved.
Quigley, W W; Ecker, S T; Vahey, P G; Synovec, R E
1999-10-01
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.
Toward development of mobile application for hand arthritis screening.
Akhbardeh, Farhad; Vasefi, Fartash; Tavakolian, Kouhyar; Bradley, David; Fazel-Rezai, Reza
2015-01-01
Arthritis is one of the most common health problems affecting people throughout the world. The goal of the work presented in this paper is to provide individuals, who may be developing or have developed arthritis, with a mobile application to assess and monitor the progress of their disease using their smartphone. The image processing algorithm includes finger border detection algorithm to monitor joint thickness and angular deviation abnormalities, which are common symptoms of arthritis. In this work, we have analyzed and compared gradient, thresholding and Canny algorithms for border detection. The effect of image spatial resolution (down-sampling) is also investigated. The results calculated based on 36 joint measurements show that the mean errors for gradient, thresholding, and Canny methods are 0.20, 2.13, and 2.03 mm, respectively. In addition, the average error for different image resolutions is analyzed and the minimum required resolution is determined for each method. The results confirm that recent smartphone imaging capabilities can provide enough accuracy for hand border detection and finger joint analysis based on gradient method.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-17
... FEDERAL COMMUNICATIONS COMMISSION [AU Docket No. 12-25; DA 12-1446] Mobility Fund Phase I Auction... Mobility Fund Phase I support to be offered in Auction 901, which is to be held on September 27, 2012, and the change of the mock auction date from September 25, 2012 to September 21, 2012. DATES: The mock...
Tao, Shengzhen; Weavers, Paul T.; Trzasko, Joshua D.; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M.; Bernstein, Matt A.
2016-01-01
PURPOSE To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. METHODS After reviewing the first-order concomitant fields that are present on asymmetric gradients, a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms is developed to counteract their effects. A numerically straightforward, simple to implement approximate solution to this pre-emphasis problem is derived, which is compatible with the current hardware infrastructure used on conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver sub-system, and its real-time use was tested using a series of phantom and in vivo data acquired from 2D Cartesian phase-difference, echo-planar imaging (EPI) and spiral acquisitions. RESULTS The phantom and in vivo results demonstrate that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images exhibiting spatially dependent blurring/distortion. The resulting artifacts are effectively prevented using the proposed gradient pre-emphasis. CONCLUSION An efficient and effective gradient pre-emphasis framework is developed to counteract the effects of first-order concomitant fields of asymmetric gradient systems. PMID:27373901
Cui, Xiquan; Ren, Jian; Tearney, Guillermo J.; Yang, Changhuei
2010-01-01
We report the implementation of an image sensor chip, termed wavefront image sensor chip (WIS), that can measure both intensity/amplitude and phase front variations of a light wave separately and quantitatively. By monitoring the tightly confined transmitted light spots through a circular aperture grid in a high Fresnel number regime, we can measure both intensity and phase front variations with a high sampling density (11 µm) and high sensitivity (the sensitivity of normalized phase gradient measurement is 0.1 mrad under the typical working condition). By using WIS in a standard microscope, we can collect both bright-field (transmitted light intensity) and normalized phase gradient images. Our experiments further demonstrate that the normalized phase gradient images of polystyrene microspheres, unstained and stained starfish embryos, and strongly birefringent potato starch granules are improved versions of their corresponding differential interference contrast (DIC) microscope images in that they are artifact-free and quantitative. Besides phase microscopy, WIS can benefit machine recognition, object ranging, and texture assessment for a variety of applications. PMID:20721059
DOT National Transportation Integrated Search
2013-08-01
As mobile technology becomes widely available and affordable, transportation agencies can use this technology to : streamline operations involved within project inspection. This research, conducted in two phases, identified : opportunities for proces...
Design and fabrication of a metamaterial gradient index diffraction grating at infrared wavelengths.
Tsai, Yu-Ju; Larouche, Stéphane; Tyler, Talmage; Lipworth, Guy; Jokerst, Nan M; Smith, David R
2011-11-21
We demonstrate the design, fabrication and characterization of an artificially structured, gradient index metamaterial with a linear index variation of Δn ~ 3.0. The linear gradient profile is repeated periodically to form the equivalent of a blazed grating, with the gradient occurring across a spatial distance of 61 μm. The grating, which operates at a wavelength of 10.6 μm, is composed of non-resonant, progressively modified "I-beam" metamaterial elements and approximates a linear phase shift gradient using 61 distinguishable phase levels. The grating structure consists of four layers of lithographically patterned metallic I-beam elements separated by dielectric layers of SiO(2). The index gradient is confirmed by comparing the measured magnitudes of the -1, 0 and +1 diffracted orders to those obtained from full wave simulations incorporating all material properties of the metals and dielectrics of the structures. The large index gradient has the potential to enable compact infrared diffractive and gradient index optics, as well as more exotic transformation optical media. © 2011 Optical Society of America
Microbial phosphorous mobilization strategies across a natural nutrient limitation gradient
NASA Astrophysics Data System (ADS)
Walker, R.; Wang, S.; Nico, P. S.; Fox, P. M.; Hao, Z.; Karaoz, U.; Torok, T.; Brodie, E.; Chakraborty, R.; Hao, Z.
2016-12-01
Phosphorus (P) is a critical nutrient and frequently limits primary productivity in terrestrial ecosystems. Microorganisms have evolved an array of strategies to mobilize occluded and insoluble P and may be important regulators of P availability to vegetation. Understanding the mechanisms of P mobilization, the breadth of microorganisms responsible, and the impact of these organisms on vegetation growth remains an important knowledge gap for both predicting ecosystem productivity and harnessing microbial functions to improve vegetation growth. To determine the relationship between soil development, phosphorus availability and P mobilizing microorganisms and their strategies we are studying a marine terrace chronosequence (Ecological Staircase, Mendocino County, CA) representing a fertility gradient culminating in P-limited pygmy forests that provide an ideal natural observatory to investigate how plant-microbe interactions co-evolve in response to P stress. Soil mineralogical analysis identified acidic soils bearing iron and aluminum phosphates and phytate as the dominant forms of occluded inorganic and organic P, respectively. Several diverse bacterial and fungal strains were isolated on media with AlPO4, FePO4, or phytate as the sole P source. Most microorganisms were able to utilize AlPO4 as a sole P source, with fewer subsisting on FePO4 or phytate. Terraces with a higher fraction of occluded and organic P harbored the greatest abundance of P-mobilizing microorganisms, with a significant proportion coming from the Burkholderia. Isolates that exhibited significant excess P mobilization were inoculated with Arabidopsis and Switchgrass plants grown with insoluble P forms had a positive impact on growth. These results indicate that rhizosphere microorganisms that have evolved under extreme nutrient limitation have an extended capacity for P solubilization, and could potentially be harnessed to alleviate P stress for plants. The detailed mechanisms for P mobilization by these isolates is under investigation.
Miehe, C; Teichtmeister, S; Aldakheel, F
2016-04-28
This work outlines a novel variational-based theory for the phase-field modelling of ductile fracture in elastic-plastic solids undergoing large strains. The phase-field approach regularizes sharp crack surfaces within a pure continuum setting by a specific gradient damage modelling. It is linked to a formulation of gradient plasticity at finite strains. The framework includes two independent length scales which regularize both the plastic response as well as the crack discontinuities. This ensures that the damage zones of ductile fracture are inside of plastic zones, and guarantees on the computational side a mesh objectivity in post-critical ranges. © 2016 The Author(s).
Controlling propagation and coupling of waveguide modes using phase-gradient metasurfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhaoyi; Kim, Myoung -Hwan; Wang, Cheng
Here, research on two-dimensional designer optical structures, or metasurfaces, has mainly focused on controlling the wavefronts of light propagating in free space. Here, we show that gradient metasurface structures consisting of phased arrays of plasmonic or dielectric nanoantennas can be used to control guided waves via strong optical scattering at subwavelength intervals. Based on this design principle, we experimentally demonstrate waveguide mode converters, polarization rotators and waveguide devices supporting asymmetric optical power transmission. We also demonstrate all-dielectric on-chip polarization rotators based on phased arrays of Mie resonators with negligible insertion losses. Our gradient metasurfaces can enable small-footprint, broadband and low-lossmore » photonic integrated devices.« less
Controlling propagation and coupling of waveguide modes using phase-gradient metasurfaces
Li, Zhaoyi; Kim, Myoung -Hwan; Wang, Cheng; ...
2017-04-17
Here, research on two-dimensional designer optical structures, or metasurfaces, has mainly focused on controlling the wavefronts of light propagating in free space. Here, we show that gradient metasurface structures consisting of phased arrays of plasmonic or dielectric nanoantennas can be used to control guided waves via strong optical scattering at subwavelength intervals. Based on this design principle, we experimentally demonstrate waveguide mode converters, polarization rotators and waveguide devices supporting asymmetric optical power transmission. We also demonstrate all-dielectric on-chip polarization rotators based on phased arrays of Mie resonators with negligible insertion losses. Our gradient metasurfaces can enable small-footprint, broadband and low-lossmore » photonic integrated devices.« less
Bobály, Balázs; Guillarme, Davy; Fekete, Szabolcs
2014-02-01
The aim of this study was to evaluate the possibilities/limitations of recent RP-LC columns packed with 1.6 μm superficially porous particles (Waters Cortecs) and to compare its potential to other existing sub-2 μm core-shell packings. The kinetic performance of Kinetex 1.3 μm, Kinetex 1.7 μm and Cortecs 1.6 μm stationary phases was assessed. It was found that the Kinetex 1.3 μm phase outperforms its counterparts for ultra-fast separations. Conversely, the Cortecs 1.6 μm packing seemed to be the best stationary phase for assays with longer analysis time in isocratic and gradient modes, considering small molecules and peptides as test probes. This exceptional behaviour was attributed to its favourable permeability and somewhat higher mechanical stability (ΔPmax of 1200 bar). The loading capacity of these three columns was also investigated with basic and neutral drugs analysed under acidic conditions. It appears that the loading capacities of Cortecs 1.6 μm and Kinetex 1.7 μm were very close, while it was reduced by 2-7-fold on the Kinetex 1.3 μm packing. However, this observation is dependent on the nature of the compound and certainly also on mobile phase conditions. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen
2014-05-01
A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.
Lei, Meikang; Peng, Fang; Ding, Tao; Zhu, Zitong; Xu, Jiawen; Wu, Xiaoqin
2015-01-01
A method based on solid phase extraction and ultra performance liquid chromatography coupled with tandem mass spectrometry (SPE-UPLC-MS/MS) has been proposed for the determination of wilforine residue in honey. After the sample was dissolved with water, concentrated and purified by an HLB solid phase extraction cartridge, the UPLC separation was performed on a Hypersil GOLD C18 column (50 mm x 2.1 mm, 1.9 microm) utilizing a gradient elution program of methanol (containing 0.15% formic acid) and water as mobile phases at a flow rate of 0. 25 mL/min. The determination was carried out with electrospray ion source in the positive mode (ESI) and multiple reaction monitoring (MRM) mode. The mass concentration of wilforine in the range of 0.01-2 microg/L was linearly correlated with the peak area, and the correlation coefficients was greater than 0.998. The limit of quantification (S/N>10) for wilforine was 0.01 microg/kg. The recoveries were 76.1% to 96.2% in the spiked levels of 0.01, 0.05 and 0.5 microg/kg with the relative standard deviations (RSD, n=6) lower than 10%. The results indicate that the method is rapid, sensitive and accurate, and can be applied for the qualitative and quantitative analysis of wilforine in honey.
Zhang, Ming; Tang, Fangliang; Xu, Jianfen; Yu, Bo; Zhang, Wei; Yao, Jianliang; Hu, Minhua
2017-10-08
A high-throughput detection method has been developed for the determination of nine perfluorinated compound precursors (PFCPs) in atmospheric precipitation by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The atmospheric precipitation samples were concentrated and purified with HLB solid phase extraction cartridges. The UPLC separation was performed on an HSS T 3 column (100 mm×2.1 mm, 1.7 μm) utilizing a gradient elution program of methanol and water as the mobile phases at a flow rate of 0.2 mL/min. The MS/MS detection was performed under negative electrospray ionization (ESI - ) in multiple reaction monitoring (MRM) mode. Good linearity was observed in the range of 0.05-5.00 μg/L, 0.50-50.0 μg/L or 5.00-500 μg/L with correlation coefficients from 0.9921 to 0.9995. The limits of detection (LODs) for the nine perfluorinated compound precursors were in the ranges of 0.05-7.9 ng/L. The recoveries ranged from 76.0% to 106% with the relative standard deviations between 0.72% and 13.7%. This method is characterized by high sensitivity and precision, extensive analytical range and quick analytical rate, and can be applied for the analysis of perfluorinated compound precursors in atmospheric precipitation.
Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao
2012-11-01
A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.
Torres-Lapasió, J R; Ruiz-Angel, M J; García-Alvarez-Coque, M C
2007-09-28
Solvation parameter models relate linearly compound properties with five fundamental solute descriptors (excess molar refraction, dipolarity/polarizability, effective hydrogen-bond acidity and basicity, and McGowan volume). These models are widely used, due to the availability of protocols to obtain the descriptors, good performance, and general applicability. Several approaches to predict retention in reversed-phase liquid chromatography (RPLC) as a function of these descriptors and mobile phase composition are compared, assaying the performance with a set of 146 organic compounds of diverse nature, eluted with acetonitrile and methanol. The approaches are classified in two groups: those that only allow predictions of retention for the mobile phases used to build the models, and those valid at any other mobile phase composition. The first group includes the use of ratios between the regressed coefficients of the solvation models that are assumed to be characteristic for a column/solvent system, and the application of offsets to transfer the retention from a reference mobile phase to any other. Maximal accuracy in predictions corresponded, however, to the approaches in the second group, which were based on models that describe the retention as a function of mobile phase composition (expressed as the solvent volume fraction or a normalised polarity measurement), where the coefficients were made dependent on the solvent descriptors. The study revealed the properties that influence the retention and distinguish the particular behaviour of acetonitrile and methanol in RPLC.
Nguyen, Thao T T; Kundan, Akshay; Wayner, Peter C; Plawsky, Joel L; Chao, David F; Sicker, Ronald J
2017-02-15
Understanding the dynamics of phase change heat and mass transfer in the three-phase contact line region is a critical step toward improving the efficiency of phase change processes. Phase change becomes especially complicated when a fluid mixture is used. In this paper, a wickless heat pipe was operated on the International Space Station (ISS) to study the contact line dynamics of a pentane/isohexane mixture. Different interfacial regions were identified, compared, and studied. Using high resolution (50×), interference images, we calculated the curvature gradient of the liquid-vapor interface at the contact line region along the edges of the heat pipe. We found that the curvature gradient in the evaporation region increases with increasing heat flux magnitude and decreasing pentane concentration. The curvature gradient for the mixture case is larger than for the pure pentane case. The difference between the two cases increases as pentane concentration decreases. Our data showed that the curvature gradient profile within the evaporation section is separated into two regions with the boundary between the two corresponding to the location of a thick, liquid, "central drop" region at the point of maximum internal local heat flux. We found that the curvature gradients at the central drop and on the flat surfaces where condensation begins are one order of magnitude smaller than the gradients in the corner meniscus indicating the driving forces for fluid flow are much larger in the corners. Copyright © 2016 Elsevier Inc. All rights reserved.
Why do disk galaxies present a common gas-phase metallicity gradient?
NASA Astrophysics Data System (ADS)
Chang, R.; Zhang, Shuhui; Shen, Shiyin; Yin, Jun; Hou, Jinliang
2017-03-01
CALIFA data show that isolated disk galaxies present a common gas-phase metallicity gradient, with a characteristic slope of -0.1dex/re between 0.3 and 2 disk effective radius re (Sanchez et al. 2014). Here we construct a simple model to investigate which processes regulate the formation and evolution.
NASA Technical Reports Server (NTRS)
Varshney, Usha; Eichelberger, B. Davis, III
1995-01-01
This paper summarizes the technique of laser-driven directional solidification in a controlled thermal gradient of yttria stabilized zirconia core coated Y-Ba-Cu-O materials to produce textured high T(sub c) superconducting polycrystalline fibers/wires with improved critical current densities in the extended range of magnetic fields at temperatures greater than 77 K. The approach involves laser heating to minimize phase segregation by heating very rapidly through the two-phase incongruent melt region to the single phase melt region and directionally solidifying in a controlled thermal gradient to achieve highly textured grains in the fiber axis direction. The technique offers a higher grain growth rate and a lower thermal budget compared with a conventional thermal gradient and is amenable as a continuous process for improving the J(sub c) of high T(sub c) superconducting polycrystalline fibers/wires. The technique has the advantage of suppressing weak-link behavior by orientation of crystals, formation of dense structures with enhanced connectivity, formation of fewer and cleaner grain boundaries, and minimization of phase segregation in the incongruent melt region.
Tsonev, Latchezar I; Hirsh, Allen G
2008-07-25
pISep is a major new advance in low ionic strength ion exchange chromatography. It enables the formation of externally controlled pH gradients over the very broad pH range from 2 to 12. The gradients can be generated on either cationic or anionic exchangers over arbitrary pH ranges wherein the stationary phases remain totally charged. Associated pISep software makes possible the calculation of either linear, nonlinear or combined, multi-step, multi-slope pH gradients. These highly reproducible pH gradients, while separating proteins and glycoproteins in the order of their electrophoretic pIs, provide superior chromatographic resolution compared to salt. This paper also presents a statistical mechanical model for protein binding to ion exchange stationary phases enhancing the electrostatic interaction theory for the general dependence of retention factor k, on both salt and pH simultaneously. It is shown that the retention factors computed from short time isocratic salt elution data of a model protein can be used to accurately predict its salt elution concentration in varying slope salt elution gradients formed at varying isocratic pH as well as the pH at which it will be eluted from an anionic exchange column by a pISep pH gradient in the absence of salt.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirigian, Stephen, E-mail: kschweiz@illinois.edu, E-mail: smirigian@gmail.com; Schweizer, Kenneth S., E-mail: kschweiz@illinois.edu, E-mail: smirigian@gmail.com
2015-12-28
We have constructed a quantitative, force level, statistical mechanical theory for how confinement in free standing thin films introduces a spatial mobility gradient of the alpha relaxation time as a function of temperature, film thickness, and location in the film. The crucial idea is that relaxation speeds up due to the reduction of both near-surface barriers associated with the loss of neighbors in the local cage and the spatial cutoff and dynamical softening near the vapor interface of the spatially longer range collective elasticity cost for large amplitude hopping. These two effects are fundamentally coupled. Quantitative predictions are made formore » how an apparent glass temperature depends on the film thickness and experimental probe technique, the emergence of a two-step decay and mobile layers in time domain measurements, signatures of confinement in frequency-domain dielectric loss experiments, the dependence of film-averaged relaxation times and dynamic fragility on temperature and film thickness, surface diffusion, and the relationship between kinetic experiments and pseudo-thermodynamic measurements such as ellipsometry.« less
Mirigian, Stephen; Schweizer, Kenneth S
2015-12-28
We have constructed a quantitative, force level, statistical mechanical theory for how confinement in free standing thin films introduces a spatial mobility gradient of the alpha relaxation time as a function of temperature, film thickness, and location in the film. The crucial idea is that relaxation speeds up due to the reduction of both near-surface barriers associated with the loss of neighbors in the local cage and the spatial cutoff and dynamical softening near the vapor interface of the spatially longer range collective elasticity cost for large amplitude hopping. These two effects are fundamentally coupled. Quantitative predictions are made for how an apparent glass temperature depends on the film thickness and experimental probe technique, the emergence of a two-step decay and mobile layers in time domain measurements, signatures of confinement in frequency-domain dielectric loss experiments, the dependence of film-averaged relaxation times and dynamic fragility on temperature and film thickness, surface diffusion, and the relationship between kinetic experiments and pseudo-thermodynamic measurements such as ellipsometry.
Mensink, M A; Šibík, J; Frijlink, H W; van der Voort Maarschalk, K; Hinrichs, W L J; Zeitler, J A
2017-10-02
Protein drugs play an important role in modern day medicine. Typically, these proteins are formulated as liquids requiring cold chain processing. To circumvent the cold chain and achieve better storage stability, these proteins can be dried in the presence of carbohydrates. We demonstrate that thermal gradient mid- and far-infrared spectroscopy (FTIR and THz-TDS, respectively) can provide useful information about solid-state protein carbohydrate formulations regarding mobility and intermolecular interactions. A model protein (BSA) was lyophilized in the presence of three carbohydrates with different size and protein stabilizing capacity. A gradual increase in mobility was observed with increasing temperature in formulations containing protein and/or larger carbohydrates (oligo- or polysaccharides), lacking a clear onset of fast mobility as was observed for smaller molecules. Furthermore, both techniques are able to identify the glass transition temperatures (T g ) of the samples. FTIR provides additional information as it can independently monitor changes in protein and carbohydrate bands at the T g . Lastly, THz-TDS confirms previous findings that protein-carbohydrate interactions decrease with increasing molecular weight of the carbohydrate, which results in decreased protein stabilization.
Fanali, Salvatore; Catarcini, Paolo; Quaglia, Maria Giovanna
2002-02-01
The separation of basic compounds into their enantiomers was achieved using capillary electrochromatography in 50 or 75 microm inner diameter (ID) fused-silica capillaries packed with silica a stationary phase derivatized with vancomycin and mobile phases composed of mixtures of polar organic solvents containing 13 mM ammonium acetate. Enantiomer resolution, electroosmotic flow, and the number of theoretical plates were strongly influenced by the type and concentration of the organic solvent. Mobile phases composed of 13 mM ammonium acetate dissolved in mixtures of acetonitrile/methanol, ethanol, n-propanol, or isopropanol were tested and the highest enantioresolutions were achieved using the first mobile phase, allowing the separation of almost all investigated enantiomers (9 from 11 basic compounds). The use of capillaries with different ID (50 and 75 microm ID) packed with the same chiral stationary phase revealed that a higher number of theoretical plates and higher enantioresolution was achieved with the tube with lowest ID.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.
Weavers, Paul T; Tao, Shengzhen; Trzasko, Joshua D; Frigo, Louis M; Shu, Yunhong; Frick, Matthew A; Lee, Seung-Kyun; Foo, Thomas K-F; Bernstein, Matt A
2018-03-01
Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second-order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth-order or B 0 ) and linear (first-order) spatial dependence. This work demonstrates a general solution to eliminate the zeroth-order concomitant field by applying the correct B 0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo-planar imaging (EPI), and fast spin-echo imaging. A global phase offset is reduced in the phase-contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase-encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast-spin echo images. A user-transparent method to compensate the zeroth-order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences-both product and research-to be retained without any modifications. Magn Reson Med 79:1538-1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Enhanced mobility of non aqueous phase liquid (NAPL) during drying of wet sand
NASA Astrophysics Data System (ADS)
Govindarajan, Dhivakar; Deshpande, Abhijit P.; Raghunathan, Ravikrishna
2018-02-01
Enhanced upward mobility of a non aqueous phase liquid (NAPL) present in wet sand during natural drying, and in the absence of any external pressure gradients, is reported for the first time. This mobility was significantly higher than that expected from capillary rise. Experiments were performed in a glass column with a small layer of NAPL-saturated sand trapped between two layers of water-saturated sand. Drying of the wet sand was induced by flow of air across the top surface of the wet sand. The upward movement of the NAPL, in the direction of water transport, commenced when the drying effect reached the location of the NAPL and continued as long as there was significant water evaporation in the vicinity of NAPL, indicating a clear correlation between the NAPL rise and water evaporation. The magnitude and the rate of NAPL rise was measured at different water evaporation rates, different initial locations of the NAPL, different grain size of the sand and the type of NAPL (on the basis of different NAPL-glass contact angle, viscosity and density). A positive correlation was observed between average rate of NAPL rise and the water evaporation while a negative correlation was obtained between the average NAPL rise rate and the NAPL properties of contact angle, viscosity and density. There was no significant correlation of average NAPL rise rate with variation of sand grain size between 0.1 to 0.5 mm. Based on these observations and on previous studies reported in the literature, two possible mechanisms are hypothesized -a) the effect of the spreading coefficient resulting in the wetting of NAPL on the water films created and b) a moving water film due to evaporation that "drags" the NAPL upwards. The NAPL rise reported in this paper has implications in fate and transport of chemicals in NAPL contaminated porous media such as soils and exposed dredged sediment material, which are subjected to varying water saturation levels due to drying and rewetting.
HPLC Determination of Esculin and Esculetin in Rat Plasma for Pharmacokinetic Studies.
Rehman, Shaheed Ur; Kim, In Sook; Kang, Ki Sung; Yoo, Hye Hyun
2015-09-01
An optimized, sensitive and validated reversed-phase high-performance liquid chromatography (RP-HPLC) method with UV detection is described for simultaneous determination of esculin and its aglycone, esculetin, in rat plasma. After addition of internal standard (chrysin), plasma samples were pretreated by solid-phase extraction and introduced into the HPLC system. Analytes were separated on a RP C18 column with a mobile phase of 0.075% acetic acid in water (solvent A) and 90% acetonitrile in solvent A (solvent B) using gradient elution at a flow rate of 1.0 mL/min. The wavelength for UV detection was set at 338 nm. Calibration curves for esculin and esculetin were constructed over a range of 10-1,000 ng/mL. The developed method was found to be specific, precise and accurate. The method was successfully applied to study the pharmacokinetics of esculin and esculetin in rats. After oral administration of 120 mg/kg, the mean Cmax values were 340.3 and 316.5 ng/mL and the AUClast values were 377.3 and 1276.5 h ng/mL for esculin and esculetin, respectively. The bioavailability of esculin was calculated to be 0.62%. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria
2008-12-23
Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.
Yuan, Jie; Zhou, Huifang; Yang, Yicong; Li, Weimin; Wan, Yi; Wang, Lili
2015-05-01
Protein-folding liquid chromatography (PFLC) is an effective and scalable method for protein renaturation with simultaneous purification. However, it has been a challenge to fully refold inclusion bodies in a PFLC column. In this work, refolding with simultaneous purification of recombinant human proinsulin (rhPI) from inclusion bodies from Escherichia coli were investigated using the surface of stationary phases in immobilized metal ion affinity chromatography (IMAC) and high-performance size-exclusion chromatography (HPSEC). The results indicated that both the ligand structure on the surface of the stationary phase and the composition of the mobile phase (elution buffer) influenced refolding of rhPI. Under optimized chromatographic conditions, the mass recoveries of IMAC column and HPSEC column were 77.8 and 56.8% with purifies of 97.6 and 93.7%, respectively. These results also indicated that the IMAC column fails to refold rhPI, and the HPSEC column enables efficient refolding of rhPI with a low-urea gradient-elution method. The refolded rhPI was characterized by circular dichroism spectroscopy. The molecular weight of the converted human insulin was further confirmed with SDS-18% PAGE, Matrix-Assisted Laser Desorption/ Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS) and the biological activity assay by HP-RPLC. Copyright © 2014 John Wiley & Sons, Ltd.
Li, Yan; Dvořák, Miloš; Nesterenko, Pavel N; Stanley, Roger; Nuchtavorn, Nantana; Krčmová, Lenka Kujovská; Aufartová, Jana; Macka, Mirek
2015-10-08
Trends towards portable analytical instrumentation of the last decades have not been equally reflected in developments of portable liquid chromatography (LC) instrumentation for rapid on-site measurements. A miniaturised medium pressure capillary LC (MPLC) system with gradient elution capability has been designed based on a flexible modular microfluidic system using primarily off-the-shelf low cost components to ensure wide accessibility to other analysts. The microfluidic platform was assembled on a breadboard and contained microsyringe pumps and switch valves, complemented with an injection valve and on-capillary detectors, all controlled by a PC. Four miniaturised microsyringe pumps, with 5, 20 and 100 μL syringe volume options, formed the basis of the pumping system. Two pairs of pumps were used for each mobile phase to create gradient elution capability. The two microsyringe pumps in each pairs were linked by two electrically operated microfluidic switching valves and both pairs of pumps were connected through a zero void volume cross-connector, thus providing a low hold-up volume for gradient formation. Sample was injected by a 20 nL nano-LC sampling valve, directly connected to a 18 cm long 100 μm i.d. Chromolith CapRod RP-18 monolithic capillary column. On-capillary LED-based UV-vis photometric detection was conducted through a piece of equal diameter fused silica capillary connected after the column. The performance of the portable LC system was evaluated theoretically and experimentally, including the maximum operating pressure, gradient mixing performance, and the performance of the detectors. The 5 μL microsyringe pump offered the best performance, with typical maximum operating pressures up to 11.4 ± 0.4 MPa (water) and gradient pumping repeatability of between 4 and 9% for gradients between 0.10% s(-1) and 0.33% s(-1). Test analytes of charged and uncharged dyes and pharmaceuticals of varying hydrophobicity showed typical RSD values of 0.7-1.4% and 3.3-4.8% in isocratic mode and 1.2-4.6% and 3.2-6.4% in gradient mode, respectively for retention time and peak area repeatability. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Immobilization and Natural Attenuation of Arsenic in Surface and Subsurface Sediments
NASA Astrophysics Data System (ADS)
O'Day, P. A.; Illera, V.; Choi, S.; Vlassopoulos, D.
2008-12-01
Understanding of molecular-scale biogeochemical processes that control the mobilization and distribution of As and other oxyanions can be used to develop remediation strategies that take advantage of natural geochemical and hydrologic gradients. Arsenic and other toxic oxyanions can be mobilized at low bulk sediment concentrations (ppm range) and thus, treatment technologies are challenged by low contaminant concentrations, widespread sources, variable pH and Eh conditions, and inaccessibility of subsurface environments. In situ chemical amendments to soils and sediments can be used to decrease the mobility and bioaccessibility of As and oxyanions through sorption to, or precipitation with, stabilizing phases. At a site near San Francisco Bay (CA, USA), treatment of As-contaminated soils with sulfate-cement amendments has effectively immobilized As. Laboratory experiments with field soils and spectroscopic characterizations showed that in high pH cement-type treatments, As is precipitated in ettringite-type phases (Ca-Al sulfates), whereas in low pH ferrous sulfate treatments, As is associated with an iron-arsenate phase (angellelite). The presence of As-associated ettringite-type phases in field sediments amended more than a decade ago indicates long-term stability of these neophases, as long as environmental conditions are relatively constant. At sites of subsurface contamination, monitored natural attenuation (MNA) as a remediation approach for As is gaining interest and acceptance. Successful implementation of MNA requires a mechanistic understanding of As sequestration processes and of the subsurface conditions that may enhance or reduce long-term effectiveness. At a former military site (MA, USA), naturally occurring As was mobilized from sediments as a result of reducing conditions from addition of organic carbon as a biodegradation treatment of chlorinated solvents. Elevated As concentrations were not detected further than about 30 m downgradient of the injection, indicating that As sequestration was also occurring by natural processes in the aquifer. Laboratory experiments with aquifer sediments and spectroscopic characterization of reaction products were used to quantify the extent of As(III) sorption and abiotic oxidation to As(V), probably by Mn(III,IV) present in sediment minerals. Interrogation by XANES spectroscopy and analysis of uptake data indicated that sediments have a limited abiotic oxidation capacity for As(III), which did not exceed 30% of the total amount of As sorbed and was estimated at 0.025 to 0.4 mmol/kg sediment. Results indicate that pH-controlled sorption is the primary mechanism for As uptake and sediment capacity for oxidative sorption is limited. As such, MNA may be temporarily effective at this site, depending on the size of the contaminant plume and the rate of groundwater flow.
Thermal-gradient migration of brine inclusions in salt crystals
NASA Astrophysics Data System (ADS)
Yagnik, S. K.
1982-09-01
High level nuclear waste disposal in a geologic repository was proposed. Natural salt deposits which are considered contain a small volume fraction of water in the form of brine inclusions distributed throughout the salt. Radioactive decay heating of the nuclear wastes will impose a temperature gradient on the surrounding salt which mobilizes the brine inclusions. Inclusions filled completely with brine migrate up the temperature gradient and eventually accumulate brine near the buried waste forms. The brine may slowly corrode or degrade the waste forms which is undesirable. In this work, thermal gradient migration of both all liquid and gas liquid inclusions was experimentally studied in synthetic single crystals of NaCl and KCl using a hot stage attachment to an optical microscope which was capable of imposing temperature gradients and axial compressive loads on the crystals. The migration velocities of the inclusion shape and size are discussed.
The rigidity and mobility of screw dislocations in a thin film
NASA Astrophysics Data System (ADS)
Wang, Fei
2018-07-01
An equation of screw dislocations in a thin film is derived for arbitrary boundary conditions. The boundary conditions can be the free surface, the fixed surface or the gradient loading imposed on the surface. The new equation makes it possible to study changes in the dislocation structure under various gradient stress applied to the surface. The rigidity and mobility of screw dislocations in a thin film are explored by using the equation. It is found that the screw dislocation core in a thin film is like a Hookean body with a specific shear stress applied to the surface. Free-surface effects on the Peierls stress are investigated and compared with previous studies. An abnormal behavior of the Peierls stress of screw dislocations in a soft-inclusion film between two rigid films is predicted theoretically.
Kao, T H; Huang, S C; Inbaraj, B Stephen; Chen, B H
2008-09-26
Gynostemma pentaphyllum (Thunb.) Makino, a traditional Chinese herb possessing antitumor and antioxidant activities, has been shown to contain several functional components like saponins and flavonoids. However, their identities remain uncertain. The objectives of this study were to develop an appropriate extraction, purification and HPLC-MS method to determine saponins and flavonoids in G. pentaphyllum. Both flavonoids and saponins were extracted with methanol, followed by purification with a C18 cartridge to elute the former with 50% methanol and the latter with 100% methanol. A total of 34 saponins were separated within 40 min by a Gemini C18 column and a gradient mobile phase of acetonitrile and 0.1% formic acid in water, in which 18 saponins were identified by LC-MS with ESI mode and Q-TOF (LC/MS/MS). Similarly, a total of eight flavonoids were separated within 45 min by the same column and a gradient solvent system of methanol and 0.1% formic acid in water, with identification being carried out by a post-column derivatization method and LC-MS with ESI mode. The amounts of flavonoids in G. pentaphyllum ranged from 170.7 to 2416.5 mug g(-1), whereas saponins were from 491.0 to 89,888.9 mug g(-1).
Lin, Q-B; Wang, T-J; Song, H; Li, B
2010-12-01
A novel and simple method to detect isothiazolinone-type biocides (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT) and 2-octyl-3-isothiazolinone (OIT)) in paper used for food packaging by ultrasonic extraction coupled with UPLC-MS/MS was developed. Parameters affecting process efficiency such as extraction solvents, UPLC mobile phase, gradient elution procedure and MS/MS conditions were studied to optimise the operating conditions. Using the optimised gradient elution procedure, the retention time was less than 6 min. The limits of detection (LODs) were found to be between 0.001 and 0.010 mg kg⁻¹, which was validated using actual concentrations. After diluting the standard solution with a blank matrix, the linear calibration curve ranges were 0.002-1.000 mg kg⁻¹ for BIT and OIT, 0.005-1.000 mg kg⁻¹ for MI, and 0.020-1.000 mg kg⁻¹ for CMI, with correlation coefficients higher than 0.9985 (n = 6). A good level of precision with a mean recovery greater than 81.3% and a relative standard deviation (RSD) less than 6.2% were also obtained. A methodology has been proposed for the analysis of isothiazolinones in paper.
Zhuang, Yaqiang; Wang, Guangming; Liang, Jiangang; Cai, Tong; Tang, Xiao-Lan; Guo, Tongfeng; Zhang, Qingfeng
2017-11-29
This paper proposes an easy, efficient strategy for designing broadband, wide-angle and polarization-independent diffusion metasurface for radar cross section (RCS) reduction. A dual-resonance unit cell, composed of a cross wire and cross loop (CWCL), is employed to enhance the phase bandwidth covering the 2π range. Both oblique-gradient and horizontal-gradient phase supercells are designed for illustration. The numerical results agree well with the theoretical ones. To significantly reduce backward scattering, the random combinatorial gradient metasurface (RCGM) is subsequently constructed by collecting eight supercells with randomly distributed gradient directions. The proposed metasurface features an enhanced specular RCS reduction performance and less design complexity compared to other candidates. Both simulated and measured results show that the proposed RCGM can significantly suppress RCS and exhibits broadband, wide-angle and polarization independence features.
Use of low volatility mobile phases in electroosmotic thin-layer chromatography.
Berezkin, V G; Balushkin, A O; Tyaglov, B V; Litvin, E F
2005-08-19
A variant of electroosmotic thin-layer chromatography is suggested with the use of low volatility compounds as mobile phases aimed at drastically decreasing the evaporation of the mobile phase and improving the reproducibility of the method. The linear movement velocity of zones of separated compounds is experimentally shown to increase 2-12-fold in electroosmotic chromatography (compared to similar values in traditional TLC). The separation efficiency is also considerably increased.
Tao, Shengzhen; Weavers, Paul T; Trzasko, Joshua D; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M; Bernstein, Matt A
2017-06-01
To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Zhang, Shuiying; Zhang, Qian; Guo, Qiang; Zhao, Yunfang; Gao, Xiaoli; Chai, Xingyun; Tu, Pengfei
2015-08-01
The root and rhizome of Litsea cubeba (Lour) Pers., named 'Dou-chi-jiang' in Chinese, has been traditionally used for treatment of cardiovascular and cerebrovascular diseases, rheumatic arthralgia, and other diseases in China. Aporphine alkaloids are its characteristic ingredients and responsible for its bioactivities, especially anti-inflammatory and analgesic effects. A sensitive and reliable high-performance liquid chromatography with diode array detection-tandem mass spectrometry method was developed for characterization and simultaneous determination of biological aporphine alkaloids in 'Dou-chi-jiang'. The optimized chromatographic conditions were performed on an Eclipse XDB C18 column with a gradient of acetonitrile/water containing 0.1% formic acid as the mass spectrometry mobile phase and acetonitrile/water containing 0.2% diethylamine (pH 3.10, adjusted by acetic acid) as the liquid chromatography mobile phase. The fragmentation pathways by loss of CO, ·CH3 , ·NH3 , and ·NH2 CH3 were detected as characteristic for aporphine alkaloids. Based on these characteristics, total 12 analogues were identified. The quantification method was validated in terms of linearity, precision, and accuracy for six major aporphine alkaloids, which was successfully applied for simultaneous determination in ten batches of samples. The established method is simple, rapid, and specific for characterization and quantitation of aporphine alkaloids in 'Dou-chi-jiang' and other traditional Chinese medicines rich in this kind of ingredient. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gao, Wenhui; Legido-Quigley, Cristina
2011-07-15
A fast and sensitive HPLC method for analysis of cosmetic creams for hydroquinone, phenol and six preservatives has been developed. The influence of sample preparation conditions and the composition of the mobile phase and elution mode were investigated to optimize the separation of the eight studied components. Final conditions were 60% methanol and 40% water (v/v) extraction of the cosmetic creams. A C18 column (100 mm × 2.1 mm) was used as the separation column and the mobile phase consisted of methanol and 0.05 mol/L ammonium formate in water (pH=3.0) with gradient elution. The results showed that complete separation of the eight studied components was achieved within 10 min, the linear ranges were 1.0-200 μg/mL for phenol, 0.1-150 μg/mL for sorbic acid, 2.0-200 μg/mL for benzoic acid, 0.5-200 μg/mL for hydroquinone, methyl paraben, ethyl paraben and propyl paraben, butyl paraben, and good linear correlation coefficient (≥0.9997) were obtained, the detection limit was in the range of 0.05-1.0 μg/mL, the average recovery was between 86.5% and 116.3%, and the relative standard deviation (RSD) was less than 5.0% (n=6). The method is easy, fast and sensitive, it can be employed to analyze component residues in cosmetic creams especially in a quality control setting. Copyright © 2011 Elsevier B.V. All rights reserved.
Roberts, Michael S.; Selvo, Nicholas S.; Roberts, Jessica K.; Daryani, Vinay M.; Owens, Thandranese S.; Harstead, K. Elaine; Gajjar, Amar; Stewart, Clinton F.
2017-01-01
A rapid and robust method for measuring methotrexate (MTX) and its two primary metabolites, 7-hydroxymethotrexate (7-OHMTX) and 2,4-diamino-N10-methylpteroic acid (DAMPA), was developed for use in pharmacokinetic studies of plasma and cerebrospinal fluid samples collected from infants with malignant brain tumors. Sample aliquots (100μL) were prepared for bioanalysis of MTX and metabolites using a Waters Oasis HLB microelution SPE plate. Chromatography was performed using a Phenomenex Synergi Polar-RP 4μ 75 × 2.0mm ID column heated to 40°C. A rapid gradient elution on a Shimadzu HPLC system was used, with mobile phase A consisting of water/formic acid (100/0.1 v/v) and mobile phase B consisting of acetonitrile/formic acid (100/0.1 v/v). Column eluent was analyzed using AB Sciex QTRAP 5500 instrumentation in electrospray ionization mode. The ion transitions (m/z) monitored were 455.2→308.1, 471.1→324.1, and 326.2→175.1 for MTX, 7-OHMTX, and DAMPA respectively. The method was linear over a range of 0.0022 – 5.5 μM for MTX, 0.0085 – 21 μM for 7-OHMTX, and 0.0031 – 7.7 μM for DAMPA. The method was applied to the analysis of serial plasma samples obtained from infants diagnosed with malignant brain tumors receiving high-dose MTX and results were compared to MTX concentrations from a TDx-FLx FPIA. PMID:28824272
Tejada-Casado, Carmen; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud
2018-03-30
Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and flow rate were carefully studied, establishing a gradient mode with a mobile phase consisted of water (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. The separation was performed on a Zorbax Eclipse Plus RRHD C 18 column (50 × 2.1 mm, 1.8 μm), involving a total analysis time lower than 12 min. Salting-out assisted liquid-liquid extraction (SALLE) was applied as sample treatment to different types of farmed fish (trout, sea bream and sea bass). To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt used. Characterization of the method in terms of performance characteristics was carried out, obtaining satisfactory results for the linearity (R 2 ≥ 0.997), repeatability (RSD ≤ 6.1%), reproducibility (RSD ≤ 10.8%) and recoveries (R ≥ 79%; RSD ≤ 7.8%). Detection limits between 0.04-29.9 μg kg -1 were obtained, demonstrating the applicability of this fast, simple and environmentally friendly method. Copyright © 2018 Elsevier B.V. All rights reserved.
Fan, Ying-Li; Ma, Ming; Cui, He-Zhen; Liu, Shu; Yang, Min-Li; Hou, Xiu-Feng
2018-05-29
A method for the determination of 22 phthalate esters in polystyrene food-contact materials has been established using ultra performance convergence chromatography with tandem mass spectrometry. In this method, 22 phthalate esters were analyzed in less than 3.5 min on an ACQUITY Tours 1-AA column by gradient elution. The mobile phase, the compensation solvent, the flow rate of mobile phase, column temperature and automatic back pressure regulator pressure were optimized, respectively. There was a good linearity of 20 phthalate esters with a range of 0.05-10 mg/L, diisodecyl phthalate and diisononyl phthalate were 0.25-10 mg/L, and the correlation coefficients of all phthalates were higher than 0.99 and those of 16 phthalates were higher than 0.999. The limits of detection and the limits of quantification of 15 phthalates were 0.02 and 0.05 mg/kg, meanwhile diallyl phthalate, diisobutyl phthalate, dimethyl phthalate, di-n-butyl phthalate and di(2-ethylhexyl) phthalate were 0.05 and 0.10 mg/kg, diisodecyl phthalate and diisononyl phthalate were 0.10 and 0.25 mg/kg. The spiked recoveries were 76.26-107.76%, and the relative standard deviations were 1.78-12.10%. Results support this method as an efficient alternative to apply for the simultaneous determination of 22 phthalate esters in common polystyrene food-contact materials. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
The effects of blocking in the subtropics on the phase speed of the MJO
NASA Astrophysics Data System (ADS)
Roundy, P. E.
2016-12-01
The phase speed of the MJO might be regulated by many different factors. Previous works have suggested that moist processes govern the phase speed, and our results show that intensification of convection is associated with reduction of phase speed down to about 5 ms-1. However, convection and rainfall decline with declining phase speeds below 5 ms-1. This presentation shows that increased Rossby wave breaking and blocking east of MJO deep convection is associated with reduced phase speed below about 6 ms-1. A wavelet filter is applied to extract time series characterized by selected zonal wavenumbers and frequencies at select equatorial base longitudes over the Indian and West Pacific Oceans. Results show that anomalies of active convection characterized by wavenumber 2 (the dominant scale of MJO convection over the warm pool) are associated with meridional potential vorticity (PV) gradients across the tropics to the east of the active convection that are near climatology for events moving east at 5 ms-1. These gradients are much weaker for slower events. The slowest phase speed events have almost no meridional PV gradients across the tropics between the mean latitudes of the subtropical jet streams, suggesting that jet exit regions occur immediately east of the deep convection, dumping mass in the upper troposphere over the region of suppressed convection. In the absence of PV gradients, synoptic to planetary scale waves moving into that environment break or cease to propagate linearly.
Zhang, Xia; Hu, Changqin
2017-09-08
Penicillins are typical of complex ionic samples which likely contain large number of degradation-related impurities (DRIs) with different polarities and charge properties. It is often a challenge to develop selective and robust high performance liquid chromatography (HPLC) methods for the efficient separation of all DRIs. In this study, an analytical quality by design (AQbD) approach was proposed for stability-indicating method development of cloxacillin. The structures, retention and UV characteristics rules of penicillins and their impurities were summarized and served as useful prior knowledge. Through quality risk assessment and screen design, 3 critical process parameters (CPPs) were defined, including 2 mixture variables (MVs) and 1 process variable (PV). A combined mixture-process variable (MPV) design was conducted to evaluate the 3 CPPs simultaneously and a response surface methodology (RSM) was used to achieve the optimal experiment parameters. A dual gradient elution was performed to change buffer pH, mobile-phase type and strength simultaneously. The design spaces (DSs) was evaluated using Monte Carlo simulation to give their possibility of meeting the specifications of CQAs. A Plackett-Burman design was performed to test the robustness around the working points and to decide the normal operating ranges (NORs). Finally, validation was performed following International Conference on Harmonisation (ICH) guidelines. To our knowledge, this is the first study of using MPV design and dual gradient elution to develop HPLC methods and improve separations for complex ionic samples. Copyright © 2017 Elsevier B.V. All rights reserved.
A broadband high-transmission gradient phase discontinuity metasurface
NASA Astrophysics Data System (ADS)
Liu, Yahong; Liu, Congcong; Song, Kun; Li, Meize; Zhao, Xiaopeng
2018-03-01
Metasurfaces have attracted significant attention due to the control of the electromagnetic waves that they enable. In this paper, we demonstrate a high-transmission gradient phase discontinuity metasurface composed of metallic rods and cylindrical dielectric resonators operating at a broadband microwave frequency from 8 GHz to 9.8 GHz, with a fractional bandwidth of 20.2%. The proposed gradient phase discontinuity metasurface can achieve complete 2π transmission phase coverage with π/4 phase intervals by varying the geometric parameters of the dielectric resonators and metallic rods. It is shown that the proposed metasurface can refract a normally incident plane wave to an angle of 30°. The broadband metasurface is flexible, and the refracted angle can be adjusted easily by varying the lattice constant. Besides the broadband anomalous refraction, we also demonstrate the metasurface can produce an interesting vortex and wave-focusing in the wide frequency range from 8 GHz to 9.8 GHz. Finally, we demonstrate that the present metasurface can tailor interference wavefronts to plane wavefronts.
Satellite mobile data service for Canada
NASA Technical Reports Server (NTRS)
Egan, Glenn R.; Sward, David J.
1990-01-01
A commercial mobile satellite system which is to be constructed and operated in Canada is examined. This is done in two phases. First, mobile data services was introduced. Hub equipment and 3000 mobile data terminals were supplied. Over the satellite tests were performed. The mobile data service provides full two way digital messaging automatic vehicle location and fleet management services. The second phase is to construct, launch and make operational the MSAT satellite and associated network control facilities. The implementation is examined of the mobile data service in Canada, including the technical description. Marketing and applications are also examined.
Liu, Yazhong; Zhou, Fang; Sang, Hua; Ye, Hui; Chen, Qianying; Yao, Lan; Ni, Ping; Wang, Guangji; Zhang, Jingwei
2017-04-15
Lysine-MCC-DM1, MCC-DM1 and DM1 are potential catabolites of trastuzumab emtansine (T-DM1). A convenient liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to detect these catabolites simultaneously in in vitro investigations for the first time. Protein precipitation was utilized to prepare the samples. Chromatographic separation was achieved on a Phenomenex Kinetex C18 column (100×2.1mm, 2.6μm) with mobile-phase gradient elution. The calibration curves of each analyte ranging from 1 to 100nM showed good linearity (r 2 >0.995). The method was validated successfully and applied to the intracellular catabolism and regulation of T-DM1. Copyright © 2017 Elsevier B.V. All rights reserved.
Instrumentation for analytical scale supercritical fluid chromatography.
Berger, Terry A
2015-11-20
Analytical scale supercritical fluid chromatography (SFC) is largely a sub-discipline of high performance liquid chromatography (HPLC), in that most of the hardware and software can be used for either technique. The aspects that separate the 2 techniques stem from the use of carbon dioxide (CO2) as the main component of the mobile phase in SFC. The high compressibility and low viscosity of CO2 mean that pumps, and autosamplers designed for HPLC either need to be modified or an alternate means of dealing with compressibility needs to be found. The inclusion of a back pressure regulator and a high pressure flow cell for any UV-Vis detector are also necessary. Details of the various approaches, problems and solutions are described. Characteristics, such as adiabatic vs. isothermal compressibility, thermal gradients, and refractive index issues are dealt with in detail. Copyright © 2015 Elsevier B.V. All rights reserved.
Móricz, Agnes M; Ott, Péter G; Alberti, Agnes; Böszörményi, Andrea; Lemberkovics, Eva; Szoke, Eva; Kéry, Agnes; Mincsovics, Emil
2013-01-01
In situ sample preparation and preparative overpressured layer chromatography (OPLC) fractionation on a 0.5 mm thick adsorbent layer of chamomile flower methanol extract prepurified by conventional gravitation accelerated column chromatography were applied in searching for bioactive components. Sample cleanup in situ on the adsorbent layer subsequent to sample application was performed using mobile phase flow in the opposite direction (the input and output of the eluent was exchanged). The antibacterial effect of the fractions obtained from the stepwise gradient OPLC separation with the flow in the normal direction was evaluated by direct bioautography against two Gram-negative bacteria: the luminescence gene tagged plant pathogenic Pseudomonas syringae pv. maculicola, and the naturally luminescent marine bacterium Vibrio fischeri. The fractions having strong activity were analyzed by SPME-GC/MS and HPLC/MS/MS. Mainly essential oil components, coumarins, flavonoids, phenolic acids, and fatty acids were tentatively identified in the fractions.
Lestremau, François; Cooper, Andrew; Szucs, Roman; David, Frank; Sandra, Pat
2006-03-24
High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.
Sun, Jianghao; Chen, Pei
2012-03-05
A practical ultra high-performance liquid chromatography (UHPLC) method was developed for fingerprint analysis of and determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity BEH C(18) column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The study is the first reported chromatographic method that separates corynanthine from yohimbine in yohimbe bark extract. The chromatographic fingerprint analysis was applied to the analysis of 18 yohimbe commercial dietary supplement samples. Quantitation of yohimbine, the traditional method for analysis of yohimbe barks, were also performed to evaluate the results of the fingerprint analysis. Wide variability was observed in fingerprints and yohimbine content among yohimbe dietary supplement samples. For most of the dietary supplements, the yohimbine content was not consistent with the label claims. Copyright © 2011. Published by Elsevier B.V.
Three filters for visualization of phase objects with large variations of phase gradients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sagan, Arkadiusz; Antosiewicz, Tomasz J.; Szoplik, Tomasz
2009-02-20
We propose three amplitude filters for visualization of phase objects. They interact with the spectra of pure-phase objects in the frequency plane and are based on tangent and error functions as well as antisymmetric combination of square roots. The error function is a normalized form of the Gaussian function. The antisymmetric square-root filter is composed of two square-root filters to widen its spatial frequency spectral range. Their advantage over other known amplitude frequency-domain filters, such as linear or square-root graded ones, is that they allow high-contrast visualization of objects with large variations of phase gradients.
Liu, Bingyi; Zhao, Jiajun; Xu, Xiaodong; Zhao, Wenyu; Jiang, Yongyuan
2017-10-23
Metasurface with gradient phase response offers new alternative for steering the propagation of waves. Conventional Snell's law has been revised by taking the contribution of local phase gradient into account. However, the requirement of momentum matching along the metasurface sets its nontrivial beam manipulation functionality within a limited-angle incidence. In this work, we theoretically and experimentally demonstrate that the acoustic gradient metasurface supports the negative reflection for all-angle incidence. The mode expansion theory is developed to help understand how the gradient metasurface tailors the incident beams, and the all-angle negative reflection occurs when the first negative order Floquet-Bloch mode dominates inside the metasurface slab. The coiling-up space structures are utilized to build desired acoustic gradient metasurface, and the all-angle negative reflections have been perfectly verified by experimental measurements. Our work offers the Floquet-Bloch modes perspective for qualitatively understanding the reflection behaviors of the acoustic gradient metasurface, and the all-angle negative reflection characteristic possessed by acoustic gradient metasurface could enable a new degree of the acoustic wave manipulating and be applied in the functional diffractive acoustic elements, such as the all-angle acoustic back reflector.
Subirats, Xavier; Bosch, Elisabeth; Rosés, Martí
2007-01-05
The use of methanol-aqueous buffer mobile phases in HPLC is a common election when performing chromatographic separations of ionisable analytes. The addition of methanol to the aqueous buffer to prepare such a mobile phase changes the buffer capacity and the pH of the solution. In the present work, the variation of these buffer properties is studied for acetic acid-acetate, phosphoric acid-dihydrogenphosphate-hydrogenphosphate, citric acid-dihydrogencitrate-hydrogencitrate-citrate, and ammonium-ammonia buffers. It is well established that the pH change of the buffers depends on the initial concentration and aqueous pH of the buffer, on the percentage of methanol added, and on the particular buffer used. The proposed equations allow the pH estimation of methanol-water buffered mobile phases up to 80% in volume of organic modifier from initial aqueous buffer pH and buffer concentration (before adding methanol) between 0.001 and 0.01 mol L(-1). From both the estimated pH values of the mobile phase and the estimated pKa of the ionisable analytes, it is possible to predict the degree of ionisation of the analytes and therefore, the interpretation of acid-base analytes behaviour in a particular methanol-water buffered mobile phase.
Ludewig, Ronny; Nietzsche, Sandor; Scriba, Gerhard K E
2011-01-01
A CEC weak cation-exchange monolith has been prepared by in situ polymerization of acrylamide, methylenebisacrylamide and 4-acrylamidobutyric acid in a decanol-dimethylsulfoxide mixture as porogen. The columns were evaluated by SEM and characterized with regard to the separation of diastereomers and α/β-isomers of aspartyl peptides. Column preparation was reproducible as evidenced by comparison of the analyte retention times of several columns prepared simultaneously. Analyte separation was achieved using mobile phases consisting of acidic phosphate buffer and ACN. Under these conditions the peptides migrated due to their electrophoretic mobility but the EOF also contributed as driving force as a function of the pH of the mobile phase due to increasing dissociation of the carboxyl groups of the polymer. Raising the pH of the mobile phase also resulted in deprotonation of the peptides reducing analyte mobility. Due to these mechanisms each pair of diastereomeric peptides displayed the highest resolution at a different pH of the buffer component of the mobile phase. Comparing the weak-cation exchange monolith to an RP monolith and a strong cation-exchange monolith different elution order of some peptide diastereomers was observed, clearly illustrating that interactions with the stationary phase contribute to the CEC separations. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Regularized lattice Boltzmann model for immiscible two-phase flows with power-law rheology
NASA Astrophysics Data System (ADS)
Ba, Yan; Wang, Ningning; Liu, Haihu; Li, Qiang; He, Guoqiang
2018-03-01
In this work, a regularized lattice Boltzmann color-gradient model is developed for the simulation of immiscible two-phase flows with power-law rheology. This model is as simple as the Bhatnagar-Gross-Krook (BGK) color-gradient model except that an additional regularization step is introduced prior to the collision step. In the regularization step, the pseudo-inverse method is adopted as an alternative solution for the nonequilibrium part of the total distribution function, and it can be easily extended to other discrete velocity models no matter whether a forcing term is considered or not. The obtained expressions for the nonequilibrium part are merely related to macroscopic variables and velocity gradients that can be evaluated locally. Several numerical examples, including the single-phase and two-phase layered power-law fluid flows between two parallel plates, and the droplet deformation and breakup in a simple shear flow, are conducted to test the capability and accuracy of the proposed color-gradient model. Results show that the present model is more stable and accurate than the BGK color-gradient model for power-law fluids with a wide range of power-law indices. Compared to its multiple-relaxation-time counterpart, the present model can increase the computing efficiency by around 15%, while keeping the same accuracy and stability. Also, the present model is found to be capable of reasonably predicting the critical capillary number of droplet breakup.
Gao, Chan; Zhang, Xueyong; Zhang, Chuanchao; Sui, Zhilei; Hou, Meng; Dai, Rucheng; Wang, Zhongping; Zheng, Xianxu; Zhang, Zengming
2018-05-17
Herein, pressure-induced phase transitions of RDX up to 50 GPa were systematically studied under different compression conditions. Precise phase transition points were obtained based on high-quality Raman spectra with small pressure intervals. This favors the correctness of the theoretical formula for detonation and the design of a precision weapon. The experimental results indicated that α-RDX immediately transformed to γ-RDX at 3.5 GPa due to hydrostatic conditions and possible interaction between the penetrating helium and RDX, with helium gas as the pressure-transmitting medium (PTM). Mapping of pressure distribution in samples demonstrates that the pressure gradient is generated in the chamber and independent of other PTMs. The gradient induced the first phase transition starts at 2.3 GPa and completed at 4.1 GPa. The larger pressure gradient promoted phase transition in advance under higher pressures. Experimental results supported that there existed two conformers of AAI and AAE for γ-RDX, as proposed by another group. δ-RDX was considered to only occur in a hydrostatic environment around 18 GPa using helium as the PTM. This study confirms that δ-RDX is independent of PTM and exists under non-hydrostatic conditions. Evidence for a new phase (ζ) was found at about 28 GPa. These 4 phases have also been verified via XRD under high pressures. In addition to this, another new phase (η) may exist above 38 GPa, and it needs to be further confirmed in the future. Moreover, all the phase transitions were reversible after the pressure was released, and original α-RDX was always obtained at ambient pressure.
Slow equilibration of reversed-phase columns for the separation of ionized solutes.
Marchand, D H; Williams, L A; Dolan, J W; Snyder, L R
2003-10-10
Reversed-phase columns that have been stored in buffer-free solvents can exhibit pronounced retention-time drift when buffered, low-pH mobile phases are used with ionized solutes. Whereas non-ionized compounds exhibit constant retention times within 20 min of the beginning of mobile phase flow, the retention of ionized compounds can continue to change (by 20% or more) for several hours. If mobile phase pH is changed from low to high and back again, an even longer time may be required before the column reaches equilibration at low pH. The speed of column equilibration for ionized solutes can vary significantly among different reversed-phase columns and is not affected by flow rate.
Demiralay, Ebru Cubuk; Cubuk, Burcu; Ozkan, Sibel A; Alsancak, Guleren
2010-11-02
In the present study, the combined effect of mobile phase polarity and pH on retention behavior of some ARA-IIs (irbesartan, losartan, valsartan and telmisartan) is investigated. The linear relationships established between retention factors of the species and the polarity parameter of the mobile phase has proved to predict accurately retention in LC as a function of the acetonitrile content (50%, 55%, 60%, v/v). The suggested model uses the pH value in the acetonitrile-water mixture as mobile phase instead of pH value in water and takes into account the effect of activity coefficients. Moreover, correlation between retention and the mobile phase pH can be established allowing prediction of the retention behavior as a function of the mobile phase pH. The model can be used to estimate the pKa in an acetonitrile percentage between 50% and 60%, at 30 degrees C. The developed method was successfully applied to both the simultaneous separation of these drug-active compounds and individual determination in their commercial pharmaceutical dosage forms.
Understanding the spreading patterns of mobile phone viruses.
Wang, Pu; González, Marta C; Hidalgo, César A; Barabási, Albert-László
2009-05-22
We modeled the mobility of mobile phone users in order to study the fundamental spreading patterns that characterize a mobile virus outbreak. We find that although Bluetooth viruses can reach all susceptible handsets with time, they spread slowly because of human mobility, offering ample opportunities to deploy antiviral software. In contrast, viruses using multimedia messaging services could infect all users in hours, but currently a phase transition on the underlying call graph limits them to only a small fraction of the susceptible users. These results explain the lack of a major mobile virus breakout so far and predict that once a mobile operating system's market share reaches the phase transition point, viruses will pose a serious threat to mobile communications.
Phase space gradient of dissipated work and information: A role of relative Fisher information
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamano, Takuya, E-mail: yamano@amy.hi-ho.ne.jp
2013-11-15
We show that an information theoretic distance measured by the relative Fisher information between canonical equilibrium phase densities corresponding to forward and backward processes is intimately related to the gradient of the dissipated work in phase space. We present a universal constraint on it via the logarithmic Sobolev inequality. Furthermore, we point out that a possible expression of the lower bound indicates a deep connection in terms of the relative entropy and the Fisher information of the canonical distributions.
Convective flows in enclosures with vertical temperature or concentration gradients
NASA Technical Reports Server (NTRS)
Wang, L. W.; Chai, A. T.; Sun, D. J.
1988-01-01
The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.
Convective flows in enclosures with vertical temperature or concentration gradients
NASA Technical Reports Server (NTRS)
Wang, L. W.; Chai, A. T.; Sun, D. J.
1989-01-01
The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.
Method for determining asphaltene stability of a hydrocarbon-containing material
Schabron, John F; Rovani, Jr., Joseph F
2013-02-05
A method for determining asphaltene stability in a hydrocarbon-containing material having solvated asphaltenes therein is disclosed. In at least one embodiment, it involves the steps of: (a) precipitating an amount of the asphaltenes from a liquid sample of the hydrocarbon-containing material with an alkane mobile phase solvent in a column; (b) dissolving a first amount and a second amount of the precipitated asphaltenes by changing the alkane mobile phase solvent to a final mobile phase solvent having a solubility parameter that is higher than the alkane mobile phase solvent; (c) monitoring the concentration of eluted fractions from the column; (d) creating a solubility profile of the dissolved asphaltenes in the hydrocarbon-containing material; and (e) determining one or more asphaltene stability parameters of the hydrocarbon-containing material.
Iterated unscented Kalman filter for phase unwrapping of interferometric fringes.
Xie, Xianming
2016-08-22
A fresh phase unwrapping algorithm based on iterated unscented Kalman filter is proposed to estimate unambiguous unwrapped phase of interferometric fringes. This method is the result of combining an iterated unscented Kalman filter with a robust phase gradient estimator based on amended matrix pencil model, and an efficient quality-guided strategy based on heap sort. The iterated unscented Kalman filter that is one of the most robust methods under the Bayesian theorem frame in non-linear signal processing so far, is applied to perform simultaneously noise suppression and phase unwrapping of interferometric fringes for the first time, which can simplify the complexity and the difficulty of pre-filtering procedure followed by phase unwrapping procedure, and even can remove the pre-filtering procedure. The robust phase gradient estimator is used to efficiently and accurately obtain phase gradient information from interferometric fringes, which is needed for the iterated unscented Kalman filtering phase unwrapping model. The efficient quality-guided strategy is able to ensure that the proposed method fast unwraps wrapped pixels along the path from the high-quality area to the low-quality area of wrapped phase images, which can greatly improve the efficiency of phase unwrapping. Results obtained from synthetic data and real data show that the proposed method can obtain better solutions with an acceptable time consumption, with respect to some of the most used algorithms.
Canceling the Gravity Gradient Phase Shift in Atom Interferometry.
D'Amico, G; Rosi, G; Zhan, S; Cacciapuoti, L; Fattori, M; Tino, G M
2017-12-22
Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.
Canceling the Gravity Gradient Phase Shift in Atom Interferometry
NASA Astrophysics Data System (ADS)
D'Amico, G.; Rosi, G.; Zhan, S.; Cacciapuoti, L.; Fattori, M.; Tino, G. M.
2017-12-01
Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.
Continuous gradient temperature Raman spectroscopy of oleic and linoleic acids from -100 to 50°C
USDA-ARS?s Scientific Manuscript database
Gradient Temperature Raman spectroscopy (GTRS) applies the temperature gradients utilized in differential scanning calorimetry (DSC) to Raman spectroscopy, providing a straightforward technique to identify molecular rearrangements that occur near and at phase transitions. Herein we apply GTRS and DS...
Carrier recovery techniques on satellite mobile channels
NASA Technical Reports Server (NTRS)
Vucetic, B.; Du, J.
1990-01-01
An analytical method and a stored channel model were used to evaluate error performance of uncoded quadrature phase shift keying (QPSK) and M-ary phase shift keying (MPSK) trellis coded modulation (TCM) over shadowed satellite mobile channels in the presence of phase jitter for various carrier recovery techniques.
Gradient Scouting in Reversed-Phase HPLC Revisited
ERIC Educational Resources Information Center
Alcazar, A.; Jurado, J. M.; Gonzalez, A. G.
2011-01-01
Gradient scouting is the best way to decide the most suitable elution mode in reversed-phase high-performance liquid chromatography (RP-HPLC). A simple rule for this decision involves the evaluation of the ratio [delta]t/t[subscript G] (where [delta]t is the difference in the retention time between the last and the first peak and t[subscript G] is…
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks.
Zhang, Qingguo; Fok, Mable P
2017-01-09
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate's target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate's target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage-distance rate and the number of moved mobile sensors, when compare with other approaches.
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks
Zhang, Qingguo; Fok, Mable P.
2017-01-01
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate’s target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate’s target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage–distance rate and the number of moved mobile sensors, when compare with other approaches. PMID:28075365
NASA Technical Reports Server (NTRS)
Palusinski, O. A.; Allgyer, T. T.
1979-01-01
The elimination of Ampholine from the system by establishing the pH gradient with simple ampholytes is proposed. A mathematical model was exercised at the level of the two-component system by using values for mobilities, diffusion coefficients, and dissociation constants representative of glutamic acid and histidine. The constants assumed in the calculations are reported. The predictions of the model and computer simulation of isoelectric focusing experiments are in direct importance to obtain Ampholine-free, stable pH gradients.
Politi, Lucia; Groppi, Angelo; Polettini, Aldo; Montagna, Maria
2004-05-10
A high performance liquid chromatographic method for toxicological drug screening of gastric content has been developed. The samples were diluted (1:3-1:30) in 0.01 N hydrochloric acid and injected into a reverse phase column for separation by gradient elution. Mobile phase consisted of solvent A (acetonitrile/water 90:10, 0.01 M sodium dodecylsulphate, 0.5% v/v glacial acetic acid) and solvent B (water/acetonitrile 90:10, 0.01 M sodium dodecylsulphate, 0.5% v/v glacial acetic acid); the gradient was programmed from 20 to 80% A in 30 min. The flow was kept constant at 1.5 ml/min. Two home-made internal standards, butyrylsalicylic acid and diacetyltubocurarine with retention times of 5.6 and 21.4 min, respectively, were used. Drugs are identified by matching their relative retention times and UV spectra (200-400 nm) with those contained in a home made library of more than 340 reference compounds (9 analgesics, 22 antidepressants, 30 antihistamines, 14 antihypertensives, 21 antirheumatics, 15 beta-blockers, 9 bronchodilators, 10 Ca antagonists, 14 diuretics, 26 neuroleptics, 25 tranquilizers, and other significant xenobiotic compounds). The fluorometric (FLD) emission spectrum (280-700 nm; excitation wavelength, 230 nm) was used as a further identification. At 50mg/l analyte concentrations, the injection of gastric content after dilution (1:3) produced S/N ratios in the range 8-140. The method is simple, rapid, rather inexpensive and proved to be a useful means of investigation if used in combination with GC-MS screening in blood. On the other hand, the system suffers from a relatively limited sensitivity for compounds with a low UV absorption and from interferences due to the presence in the matrix of some highly UV- and FL-responsive compounds (e.g. tryptophan).
Mobile, stationary and mixed phase tracers: consequences to sea ice biogeochemistry
NASA Astrophysics Data System (ADS)
Jeffery, N.; Elliott, S.; Hunke, E. C.; Deal, C.; Jin, M.
2016-02-01
Models of brine motion in sea ice have offered mechanisms for transporting biogeochemical compounds vertically within the ice and between the ice-ocean interface. In these models, sea ice microstructure and/or gross physical properties determine the resupply of nitrate, for example, to sympagic algae and that resupply, in large part, constrains sea ice primary production. The assumption of brine transport models is that the transported matter exists in a purely mobile phase within the ice brine channels. As a result, non-reacting, mobile phase tracers evolve like salinity in dynamic sea ice. Field and laboratory observations indicate that this is a good approximation for the primary algal macronutrients - nitrate, silicate and phosphate, but clear deviations are evident for ammonium, micronutrients such as iron, humic substances, algal bi-products such as gels and extracellular polysaccharides, and the algae themselves. This wide range of biogeochemical matter resists brine motion and is present in both the mobile and stationary phases, i.e. these tracers are "mixed" with respect to their transport phases. Although the precise mechanism for this resistance may be due to attachment by frustules, "stickiness" of the material surface, adsorption, or, in the case of microorganisms, active motility, a key common element in all cases is the presence of the ice matrix. In this presentation we investigate the consequences of mixed phase tracers in sea ice on algal concentrations, vertical distributions, and the potential accumulation of biogeochemical matter within the ice. We assume that sea ice growth promotes retention to the stationary phase, while melt and the disintegration of the ice matrix promotes release into the mobile phase. By varying the retention and release timescales of this formulation, we retrieve the purely mobile and maximal accumulation limits.
Pan, Wenbo; Huang, Cheng; Pu, Mingbo; Ma, Xiaoliang; Cui, Jianhua; Zhao, Bo; Luo, Xiangang
2016-02-19
The absorptive and radiative losses are two fundamental aspects of the electromagnetic responses, which are widely occurring in many different systems such as waveguides, solar cells, and antennas. Here we proposed a metasurface to realize the control of the absorptive and radiative loss and to reduce the radar cross section (RCS) in multi-frequency bands. The anti-phase gradient and absorptive metasurfaces were designed that consists of metallic square patch and square loop structure inserted with resistors, acting as an phase gradient material in the X and Ku band, while behaving as an absorber in the S band. The simulation and experiment results verified the double-band, wideband and polarization-independent RCS reduction by the absorptive and anti-phase gradient metasurfaces.
Phase II Historic Resources Survey Archaeological Testing of Site 9FU416 Fulton County, Georgia
2003-06-01
Archaeological Park, Moundville, Alabama ) for final curation. 6 Phase 11 Testing 9FUJ 416 Chapter 3. Environmental and Cultural Overview Human...Corps of Engineers, Mobile District PO Box 2288 Mobile, Alabama 36628-0001 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING...MONITORING AGENCY REPORT NUMBER US Army Corps of Engineers, Mobile District PO Box 2288 Mobile, Alabama 36628-0001 1I. SUPPLEMENTARY NOTES DISTIR 11IT!O N
Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui
2011-09-01
The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues. Copyright © 2011 Elsevier B.V. All rights reserved.
Explaining social class differences in depression and well-being.
Stansfeld, S A; Head, J; Marmot, M G
1998-01-01
Work characteristics, including skill discretion and decision authority, explain most of the socioeconomic status gradient in well-being and depression in middle-aged British civil servants from the Whitehall II Study, London. Social support explained about one-third of the gradient, life events and material difficulties less than one-third. Socioeconomic status was measured by employment grade. Work characteristics were based on the Karasek model, social support was measured by the Close Persons Questionnaire, depression by the General Health Questionnaire and well-being by the Affect Balance Scale. Despite a small contribution from social selective factors measured by upward mobility, the psychosocial work environment explained most of the cross-sectional socioeconomic status gradient in well-being and depression.
Phase gradient metasurface with broadband anomalous reflection based on cross-shaped units
NASA Astrophysics Data System (ADS)
Chen, Zhaobin; Deng, Hui; Xiong, Qingxu; Liu, Chen
2018-03-01
It has been pointed out by many documents that a phase gradient metasurface with wideband characteristics can be designed by the unit with a low-quality factor ( Q value). In this paper, a cross-shaped unit with a low-quality factor Q is proposed. By changing the variable parameters of the unit, it is found that the reflection phase of the unit can achieve a stable distribution of phase gradient in the frequency range of 8.0-20.0 GHz. we analyze variation of the electromagnetic field distribution on the unit with frequency and find that the size along electrical field polarization of electromagnetic field distribution area changes with frequency. Based on our design, effective size of electromagnetic field distribution area keeps meeting the subwavelength condition, thus stable phase distribution is gained across broadened bandwidth. It is found by the analysis of the phase gradient metasurface composed of seven units that the metasurface can exhibit anomalous reflection in the wide frequency band of 8.0-20.0 GHz, and the efficiency of abnormal reflection is higher in the range of 10.0-18.0 GHz. The error between the simulation results of abnormal reflection angle and the theoretical result is only - 1.5° to 0.5° after the work of comparison. Therefore, the metasurface designed by the new cross-shaped unit has a good control on the deflection direction of the reflected wave, and shows obvious advantages in widening the bandwidth.
Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto; Kudoh, Shoji
2017-07-01
To compare the craniocaudal gradients of the maximum pixel value change rate (MPCR) during tidal breathing between chronic obstructive pulmonary disease (COPD) patients and normal subjects using dynamic chest radiography. This prospective study was approved by the institutional review board and all participants provided written informed consent. Forty-three COPD patients (mean age, 71.6±8.7 years) and 47 normal subjects (non-smoker healthy volunteers) (mean age, 54.8±9.8 years) underwent sequential chest radiographs during tidal breathing in a standing position using dynamic chest radiography with a flat panel detector system. We evaluated the craniocaudal gradient of MPCR. The results were analyzed using an unpaired t-test and the Tukey-Kramer method. The craniocaudal gradients of MPCR in COPD patients were significantly lower than those in normal subjects (right inspiratory phase, 75.5±48.1 vs. 108.9±42.0s -1 cm -1 , P<0.001; right expiratory phase, 66.4±40.6 vs. 89.8±31.6s -1 cm -1 , P=0.003; left inspiratory phase, 75.5±48.2 vs. 108.2±47.2s -1 cm -1 , P=0.002; left expiratory phase, 60.9±38.2 vs. 84.3±29.5s -1 cm -1 , P=0.002). No significant differences in height, weight, or BMI were observed between COPD and normal groups. In the sub-analysis, the gradients in severe COPD patients (global initiative for chronic obstructive lung disease [GOLD] 3 or 4, n=26) were significantly lower than those in mild COPD patients (GOLD 1 or 2, n=17) for both right and left inspiratory/expiratory phases (all P≤0.005). A decrease of the craniocaudal gradient of MPCR was observed in COPD patients. The craniocaudal gradient was lower in severe COPD patients than in mild COPD patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Ammonium fluoride as a mobile phase additive in aqueous normal phase chromatography.
Pesek, Joseph J; Matyska, Maria T
2015-07-03
The use of ammonium fluoride as a mobile phase additive in aqueous normal phase chromatography with silica hydride-based stationary phases and mass spectrometry detection is evaluated. Retention times, peak shape, efficiency and peak intensity are compared to the more standard additives formic acid and ammonium formate. The test solutes were NAD, 3-hydroxyglutaric acid, α-ketoglutaric acid, p-aminohippuric acid, AMP, ATP, aconitic acid, threonine, N-acetyl carnitine, and 3-methyladipic acid. The column parameters are assessed in both the positive and negative ion detection modes. Ammonium fluoride is potentially an aggressive mobile phase additive that could have detrimental effects on column lifetime. Column reproducibility is measured and the effects of switching between different additives are also tested. Copyright © 2015 Elsevier B.V. All rights reserved.
Gachon, B; Desseauve, D; Fradet, L; Decatoire, A; Lacouture, P; Pierre, F; Fritel, X
2016-06-01
The role of pregnancy in pelvic floor disorders occurrence remains poorly known. It might exist a link between changes in ligamentous laxity and changes in pelvic organ mobility during this period. Our objective was to conduct a non-systematic review of literature about changes in pelvic organ mobility as well as in ligamentous laxity during pregnancy and postpartum. From the PubMed, Medline, Cochrane Library and Web of Science database we have selected works which pertains clinical assessment of pelvic organ mobility (pelvic organ prolapse quantification), ultrasound assessment of levator hiatus and urethral mobility, ligamentous laxity assessment during pregnancy and postpartum. Clinical assessments performed in these works show an increase of pelvic organ mobility and perineal distension during pregnancy followed by a recovery phase during postpartum. Pelvic floor imaging shows an increase of levator hiatus area and urethral mobility during pregnancy then a recovery phase in postpartum. Different authors also report an increase of ligamentous laxity (upper and lower limbs) during pregnancy followed by a decrease phase in postpartum. Pelvic organ mobility, ligamentous laxity, levator hiatus and urethral mobility change in a similarly way during pregnancy (increase of mobility or distension) and postpartum (recovery). 3. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Ye, Jincui; Yu, Wenying; Chen, Guosheng; Shen, Zhengrong; Zeng, Su
2010-08-01
The enantio-separations of eight 2-arylpropionic acid nonsteroidal anti-inflammatory drugs (2-APA NSAIDs) were established using reversed-phase high-performance liquid chromatography with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive for studying the stereoselective skin permeation of suprofen, ketoprofen, naproxen, indoprofen, fenoprofen, furbiprofen, ibuprofen and carprofen. The effects of the mobile phase composition, concentration of HP-beta-CD and column temperature on retention and enantioselective separation were investigated. With 2-APA NSAIDs as acidic analytes, the retention times and resolutions of the enantiomers were strongly related to the pH of the mobile phase. In addition, both the concentration of HP-beta-CD and temperature had a great effect on retention time, but only a slight or almost no effect on resolutions of the analytes. Enantioseparations were achieved on a Shimpack CLC-ODS (150 x 4.6 mm i.d., 5 microm) column. The mobile phase was a mixture of methanol and phosphate buffer (pH 4.0-5.5, 20 mM) containing 25 mM HP-beta-CD. This method was flexible, simple and economically advantageous over the use of chiral stationary phase, and was successfully applied to the enantioselective determination of the racemic 2-APA NSAIDs in an enantioselective skin permeation study.
Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian
2017-01-01
Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of “true” normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations. PMID:29190788
Ringstad, Geir; Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian
2017-01-01
Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations.
Wang, Qing; Chen, Xianbo; Qiu, Bin; Zhou, Liang; Zhang, Hui; Xie, Juan; Luo, Yan; Wang, Bin
2016-04-01
In the present study, 11 4,4'-diaminostilbene-2,2'-disulfonic acid based fluorescent whitening agents with different numbers of sulfonic acid groups were separated by using an ionic liquid as a mobile phase additive in high-performance liquid chromatography with fluorescence detection. The effects of ionic liquid concentration, pH of mobile phase B, and composition of mobile phase A on the separation of fluorescent whitening agents were systematically investigated. The ionic liquid tetrabutylammonium tetrafluoroborate is superior to tetrabutylammomnium bromide for the separation of the fluorescent whitening agents. The optimal separation conditions were an ionic liquid concentration at 8 mM and the pH of mobile phase B at 8.5 with methanol as mobile phase A. The established method exhibited low limits of detection (0.04-0.07 ng/mL) and wide linearity ranges (0.30-20 ng/mL) with high linear correlation coefficients from 0.9994 to 0.9998. The optimized procedure was applied to analyze target analytes in paper samples with satisfactory results. Eleven target analytes were quantified, and the recoveries of spiked paper samples were in the range of 85-105% with the relative standard deviations from 2.1 to 5.1%. The obtained results indicated that the method was efficient for detection of 11 fluorescent whitening agents. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Electronic transport in smectic liquid crystals
NASA Astrophysics Data System (ADS)
Shiyanovskaya, I.; Singer, K. D.; Twieg, R. J.; Sukhomlinova, L.; Gettwert, V.
2002-04-01
Time-of-flight measurements of transient photoconductivity have revealed bipolar electronic transport in phenylnaphthalene and biphenyl liquid crystals (LC), which exhibit several smectic mesophases. In the phenylnaphthalene LC, the hole mobility is significantly higher than the electron mobility and exhibits different temperature and phase behavior. Electron mobility in the range ~10-5 cm2/V s is temperature activated and remains continuous at the phase transitions. However, hole mobility is nearly temperature independent within the smectic phases, but is very sensitive to smectic order, 10-3 cm2/V s in the smectic-B (Sm-B) and 10-4 cm2/V s in the smectic-A (Sm-A) mesophases. The different behavior for holes and electron transport is due to differing transport mechanisms. The electron mobility is apparently controlled by rate-limiting multiple shallow trapping by impurities, but hole mobility is not. To explain the lack of temperature dependence for hole mobility within the smectic phases we consider two possible polaron transport mechanisms. The first mechanism is based on the hopping of Holstein small polarons in the nonadiabatic limit. The polaron binding energy and transfer integral values, obtained from the model fit, turned out to be sensitive to the molecular order in smectic mesophases. A second possible scenario for temperature-independent hole mobility involves the competion between two different polaron mechanisms involving so-called nearly small molecular polarons and small lattice polarons. Although the extracted transfer integrals and binding energies are reasonable and consistent with the model assumptions, the limited temperature range of the various phases makes it difficult to distinguish between any of the models. In the biphenyl LCs both electron and hole mobilities exhibit temperature activated behavior in the range of 10-5 cm2/V s without sensitivity to the molecular order. The dominating transport mechanism is considered as multiple trapping in the impurity sites. Temperature-activated mobility was treated within the disorder formalism, and activation energy and width of density of states have been calculated.
Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M
2015-11-20
The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.
Ashraf-Khorassani, M; Yan, Q; Akin, A; Riley, F; Aurigemma, C; Taylor, L T
2015-10-30
Method development for normal phase flash liquid chromatography traditionally employs preliminary screening using thin layer chromatography (TLC) with conventional solvents on bare silica. Extension to green flash chromatography via correlation of TLC migration results, with conventional polar/nonpolar liquid mixtures, and packed column supercritical fluid chromatography (SFC) retention times, via gradient elution on bare silica with a suite of carbon dioxide mobile phase modifiers, is reported. Feasibility of TLC/SFC correlation is individually described for eight ternary mixtures for a total of 24 neutral analytes. The experimental criteria for TLC/SFC correlation was assumed to be as follows: SFC/UV/MS retention (tR) increases among each of the three resolved mixture components; while, TLC migration (Rf) decreases among the same resolved mixture components. Successful correlation of TLC to SFC was observed for most of the polar organic solvents tested, with the best results observed via SFC on bare silica with methanol as the CO2 modifier and TLC on bare silica with a methanol/dichloromethane mixture. Copyright © 2015 Elsevier B.V. All rights reserved.
Baranowska, Irena; Płonka, Joanna
2016-04-01
A high-performance liquid chromatography method for simultaneous separation and determination of biogenic amines [dopamine, epinephrine, serotonin and its six metabolites (normetanephrine, metanephrine, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol, homovanilic acid and 5-hydroxyindoloacetic acid)] with drugs from different therapeutically groups [analgesics (paracetamol, metamizol), diuretics (furosemide) and antibiotics (cefazolin, fluconazole)] was developed. A chromatographic column with pre-column with octadecylsilane phase (C18e ) and two detectors - diode array serial connected and fluorescence - was used. Gradient elution of mixture of acetate buffer (pH 4.66) and methanol as a mobile phase was applied. The limit of detection (LOD) of 8-10 ng/mL and limit of quantitation (LOQ) of 24-30 ng/mL for biogenic amines, as well as the LOD of 50-100 ng/mL and the LOQ of 150-300 ng/mL for drugs, were determined. The applied sample preparation method allowed recoveries of 93% for the biogenic amines and 92% for the drugs to be achieved. The developed procedure has been applied to simultaneous determination of the examined compounds in urine samples and could be used in clinical analysis. Copyright © 2015 John Wiley & Sons, Ltd.
Machonis, Philip R; Jones, Matthew A; Kwik-Uribe, Catherine; Dowell, Dawn
2014-01-01
Single-laboratory validation data were reviewed by the Expert Review Panel (ERP) of the Stakeholder Panel on Strategic Food Analytical Methods at the AOAC Mid-Year Meeting, March 12-14, 2013, in Rockville, MD. The ERP determined that the data presented met established standard method performance requirements and adopted a method for determination of flavanols and procyanidins (DP 1-10) in cocoa-based ingredients and products by ultra-HPLC as AOAC Official First Action Method 2013.03 on March 14, 2013. The flavanols and procyanidins (DP 1-10) are eluted using a binary gradient (solvents A and B) consisting of 98 + 2 (v/v) acetonitrile-glacial acetic acid (A) and 95 + 3 + 2 (v/v/v) methanol-water-glacial acetic acid (B). The mobile phase is applied to a diol stationary phase. Detection occurs using fluorescence detection. Recovery of flavanols and procyanidins (DP 1-10) from both high- and low-fat matrixes was 98.4-99.8%. Precision was determined for seven different sample types (cocoa extract, cocoa nib, natural cocoa powder, cocoa liquor, alkalized cocoa powder, dark chocolate, and milk chocolate).
Ultra-performance liquid chromatographic determination of tocopherols and retinol in human plasma.
Bell, Edward C; John, Mathew; Hughes, Rodney J; Pham, Thu
2014-10-01
A rapid, selective and sensitive ultra-performance liquid chromatography method has been developed for the detection and quantification of tocopherols and retinol in human plasma. Alpha-tocopherol, gamma-tocopherol and retinol are assayed using fluorescence detection. Excitation/emission wavelengths are 295/330 nm and 325/470 nm for the analysis of both tocopherols and retinol, respectively. Retinol acetate is employed as the internal standard. The reversed-phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds is achieved using a bridged ethyl hybrid C18 column. The retention times for retinol, retinol acetate, gamma-tocopherol and alpha-tocopherol are 1.6, 1.8, 3.9 and 4.3 min, respectively. The limits of quantification for retinol, gamma-tocopherol and alpha-tocopherol were 0.02, 0.02 and 0.1 µg/mL, respectively. The assay method is suitable for the analysis of tocopherols and retinol in human plasma. The method may be applied following the ingestion of foods fortified with these fat-soluble vitamins. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Hetrick, Evan M; Kramer, Timothy T; Risley, Donald S
2017-03-17
Based on a column-screening exercise, a column ranking system was developed for sample mixtures containing any combination of 26 sugar and sugar alcohol analytes using 16 polar stationary phases in the HILIC mode with acetonitrile/water or acetone/water mobile phases. Each analyte was evaluated on the HILIC columns with gradient elution and the subsequent chromatography data was compiled into a statistical software package where any subset of the analytes can be selected and the columns are then ranked by the greatest separation. Since these analytes lack chromophores, aerosol-based detectors, including an evaporative light scattering detector (ELSD) and a charged aerosol detector (CAD) were employed for qualitative and quantitative detection. Example qualitative applications are provided to illustrate the practicality and efficiency of this HILIC column ranking. Furthermore, the design-space approach was used as a starting point for a quantitative method for the trace analysis of glucose in trehalose samples in a complex matrix. Knowledge gained from evaluating the design-space led to rapid development of a capable method as demonstrated through validation of the following parameters: specificity, accuracy, precision, linearity, limit of quantitation, limit of detection, and range. Copyright © 2017 Elsevier B.V. All rights reserved.
Viñas, Pilar; Campillo, Natalia; Pastor-Belda, Marta; Oller, Ainhoa; Hernández-Córdoba, Manuel
2015-01-09
Phthalic acid esters (PEs) were preconcentrated from cleaning products, detergents and cosmetics using ultrasound assisted extraction (UAE) in the presence of acetonitrile, and then submitted to dispersive liquid-liquid microextraction (DLLME). For DLLME, 3mL of acetonitrile extract, 150μL carbon tetrachloride and 10mL aqueous solution were used. The enriched organic phase was evaporated, reconstituted with 25μL acetonitrile and injected into a liquid chromatograph with a mobile phase (acetonitrile:10mM ammonium acetate, pH 4) under gradient elution. Detection was carried out using both diode-array (DAD) and electrospray-ion trap-tandem mass spectrometry (ESI-IT-MS/MS) in the multiple reaction monitoring mode (MRM) of the positive fragment ions. Quantification was carried out using matrix-matched standards. Detection limits were in the range 0.04-0.45ngmL(-1) for the six PEs considered. The recoveries obtained were in the 84-124% range, with RSDs lower than 10%. Thirty three different cleaning products were analyzed. The most frequently found compound was diethyl phthalate. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali
2013-11-01
In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.
Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei
2009-03-20
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.
Di Sabatino, Marcello; Di Pietra, Anna Maria; Benfenati, Luigi; Di Simone, Bruno
2007-01-01
A liquid chromatography (LC) method is described for the simultaneous determination of 10 commonly used sulfonamide drug residues in meat. The 10 sulfonamide drugs of interest were sulfadiazine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethizole, sulfamonomethoxine, sulfachloropyridazine, sulfadoxine, sulfadimethoxine, and sulfaquinoxaline. The residues were extracted with acetone-chloroform (1 + 1). Sulfonamides were quantitatively retained in the extracting solution and afterwards eluted from a cation-exchanger solid-phase extraction cartridge with a solution of methanol-aqueous ammonia. The solution was dried, reconstituted with 5 mL methanol and filtered before analysis by LC-ultraviolet using a C18 column with a mobile phase gradient of potassium dihydrogen phosphate buffer, pH 2.5, and methanol-acetonitrile (30 + 70, v/v). The method was applied to cattle, swine, chicken, and sheep muscle tissues. The validation was performed with a fortified cattle meat sample at level of 100 ppb, which is the administrative maximum residue limit for sulfonamides in the European Union. The limit of quantitation for all sulfonamides was between 3 and 14 ppb. Recovery was evaluated for different meat matrixes. The mean recovery values were between 66.3% for pork meat samples and 71.5% for cattle meat samples.
Chen, Tse-Hsien; Misra, Tarun Kumar; Liu, Chuen-Ying
2008-04-01
A macrocyclic polyamine, 1,5,9,13,17,21,25,29-octaazacyclodotriacontane ([32]ane-N(8)), in the bonded phase was employed as a molecular receptor for CEC separation of oligopeptides. Parameters affecting the performance of the separations were considered. Baseline separation for the mixture of angiotensin I, angiotensin II, [Sar(1), Thr(8)]-angiotensin II, beta-casomorphin bovine, beta-casomorphin human, oxytocin acetate, tocinoic acid, vasopressin, and FMRF amide could be achieved using phosphate buffer (30 mM, pH 7) as the mobile phase. Column efficiency with average theoretical plate numbers of 69 000 plates/m and RSDs of <1% (n = 6) was achieved. [Met(5)]-enkephalin and [Leu(5)]-enkephalin, which have identical pI values and similar masses could be completely separated using acetate buffer (30 mM) with pH gradient (pH 3 inlet side and pH 4 outlet side). The results suggest that the mechanism for the peptide separation was mediated by a combination of electrophoretic migration and chromatographic retention involving anion coordination and anion exchange. After long-term use, the deviation of the EOF of the column after more than 600 injections was still within 6.0% of that for a freshly prepared column.
Green, Curtis O; Wheatley, Andrew O; Osagie, Anthony U; St A Morrison, Errol Y; Asemota, Helen N
2007-01-01
The concentrations of the polymethoxylated flavones (PMFs) in peels of selected citrus cultivars grown in Jamaica and Mexico were determined. The PMFs were extracted from sun-dried citrus peels with reagent-grade methanol. Analyses were carried out by reverse-phase HPLC and UV detection. The column used was a C(18) 5 microm (150 x 4.6 mm) Discovery column. Elution was in the gradient mode, using a ternary mobile phase. The results showed that all the citrus cultivars used contained at least three of the six major PMFs quantified. Ortanique peel contained the highest quantity of PMFs (34,393 +/- 272 ppm), followed by tangerine (28,389 +/- 343 ppm) and Mexican sweet orange (sample 1; 21,627 +/- 494 ppm). The major PMFs, i.e. sinensetin, nobiletin, tangeretin, heptamethoxyflavone, tetramethylscutellarein and hexamethyl-o-quercetagetin, present in the peels of 20 citrus cultivars, was quantified. The results were compared with those of Florida citrus peels. A large amount of citrus peels and byproducts are produced in the Caribbean which could provide a cheap and convenient source of PMFs. Copyright 2006 John Wiley & Sons, Ltd.
Beňo, Erik; Góra, Róbert; Hutta, Milan
2018-02-01
The work is focused on the development of a high-performance liquid chromatography method with diode-array detection for the separation and quantitation of the three most abundant amino sugars; d-glucosamine, d-galactosamine, and d-mannosamine. The high-performance liquid chromatography separation was carried out by reversed-phase chromatography on Chromolith Performance RP-18e monolithic column after acid hydrolysis (5 M HCl) and precolumn derivatization of samples using diethyl ethoxymethylenemalonate. Gradient elution and a mobile phase composed of ammonium formate buffer solution (10 mmol/L, pH 3.60) and methanol with flow rate of 1.0 mL/min were used. The monitoring wavelength was set at 280 nm. The limits of detection and quantitation for analytes ranged from 0.017 to 0.122 mg/L and from 0.057 to 0.407 mg/L, respectively. The proposed method was successfully applied for the determination of amino sugars in samples of humic acids isolated from different soils and peat. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma.
Kiesel, Brian F; Parise, Robert A; Wong, Alvin; Keyvanjah, Kiana; Jacobs, Samuel; Beumer, Jan H
2017-02-05
Neratinib is an orally available tyrosine kinase inhibitor targeting HER2 (ERBB2) and EGFR (ERBB). It is being clinically evaluated for the treatment of breast and other solid tumors types as a single agent or in combination with other chemotherapies. In support of several phase I/II clinical trials investigating neratinib combinations, we developed and validated a novel LC-MS/MS assay for the quantification of neratinib in 100μL of human plasma with a stable isotopic internal standard. Analytes were extracted from plasma using protein precipitation and evaporation of the resulting supernatant followed by resuspension. Chromatographic separation was achieved using an Acquity UPLC BEH Shield RP18 column and a gradient methanol-water mobile phase containing 10% ammonium acetate. An ABI 4000 mass spectrometer and electrospray positive mode ionization were used for detection. The assay was linear from 2 to 1,000ng/mL and proved to be accurate (98.9-106.5%) and precise (<6.2%CV), and met the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be an essential tool to further define the pharmacokinetics of neratinib. Copyright © 2016 Elsevier B.V. All rights reserved.
Bhatta, R S; Kumar, D; Chhonker, Y S; Jain, G K
2011-09-01
A sensitive and selective liquid chromatography/tandem mass spectrometric method was developed for simultaneous determination of E- and Z-guggulsterone isomers (antihyperlipidemic drug) in rabbit plasma. Both the isomers were resolved on a Symmetry-Shield C(18) (5 µm, 4.6 × 150 mm) column, using gradient elution comprising a mobile phase of methanol, 0.5% v/v formic acid and acetonitrile. With dexamethasone as internal standard, plasma samples were extracted by an automated solid-phase extraction method using C(18) cartridges. Detection was performed by electrospray ionization in multiple reaction monitoring (MRM) in positive mode. The calibration curve was linear over the concentration range of 1.56-200 ng/mL (r(2) ≥ 0.998) for both analytes. The intra-day and inter-day accuracy and precision were within -0.96 to 4.12 (%bias) and 2.73 to 8.00 (%RSD) respectively. The analytes were stable after three freeze-thaw cycles. The method was successfully applied to study steriospecific pharmacokinetics of E- and Z-guggulsterone in NZ rabbit. Copyright © 2011 John Wiley & Sons, Ltd.
Babu, Sainath; Uppu, Sannihith N; Martin, Brittany; Agu, Ogad A; Uppu, Rao M
2015-01-01
We have developed a simple, reversed-phase high-performance liquid chromatography (RP-HPLC) method for the determination of bisphenol A (BPA) in thermal paper cash register receipts (CRs). The method is suitable for analysis of other types of bisphenols and it involves an overnight extraction of CRs with acetonitrile (AN) at 50 °C followed by the HPLC analysis on a Supelcosil LC18 column (150 × 4.6 mm, particle size: 5 μ) using 50% AN in water as the mobile phase (5 min, isocratic). The composition of AN in the mobile phase changed to 100% over a 10 min period (linear gradient) and then held at 100% AN for 10 min (isocratic). The flow rate was set at 1 mL/min (injection volume: 20 μL) and the eluent was monitored at 234 nm. The authentic BPA eluted with a retention time of 5.9 min and gave a linear detector response in the concentration range of 0.23-50 mg/L. BPA in the CR extracts also eluted with the same retention and had identical absorbance properties as the standard. When CR extracts were co-injected with authentic BPA, they were resolved as a single peak. Further, GC/MS/EI analysis of authentic BPA and the HPLC-purified CR extracts have identical ion chromatograms and fragmentation of the molecular ion (m/z = 228). We have analyzed 170 CRs collected from 62 different vendors including supermarkets, fast food restaurants, gas stations and banking outlets. Almost all cash receipts (n = 168) showed the presence of BPA in the concentration range of 0.45-4.26% (M ± SD, 1.54 ± 0.73%).
Effect of enzyme on extraction of ginsenoside Rb1 and Rg3 from Panax notoginseng roots
NASA Astrophysics Data System (ADS)
Phuong, Nguyen Tran Xuan; Thy, Lu Thi Mong; Khang, Nguyen Luu Vinh; My, Huynh Thi Kieu; Tam, Nguyen Le Phuong; Hieu, Nguyen Huu
2018-04-01
Panax notoginseng is distributed throughout the north and northwest of Vietnam, especially Ha Giang, Lao Cai, and Cao Bang provinces. The root of this plant contains ginsenosides (Rb1, Rb2, Rd, Rg3), flavonoids, polyacetylene, polysaccharides, amino acids, fatty acids, and peptides. In this study, the ratios of enzyme (Viscozyme, Termamyl, Cellulase), solvent of components, and time extraction were investigated. The results showed that the highest contents of Rb1 and Rg3 were achieved in the sample extracted with the ratio of enzymes V:C:T = 1:0:0, ethanol:water (60:40, v/v) as extracting solvent in 45 minutes. Then, conditions of high performance liquid chromatography with diode array detector method to determine the content of ginsenosides Rb1 and Rg3 in the roots of Panax notoginseng were studied, including wavelength, mobile phase, and flow rate. The separation was subjected on a reversed-phase C18 column using acetonitrile (A) and water (B) as mobile phase. The gradient elution was set as follow: 0-10 min, 15-25% A; 10-20 min, 25-30% A; 20-40 min, 30-60% A; 40-60 min, 60-80% A; and 60-65 min back to 15% A before the next injection, at a flow rate of 0.5 mL/min, and the wavelength was set at 202 nm. The linear range was from 298.59 to 696.72 µg/mL for Rb1 and from 8.19 to 19.10 µg/L for Rg3. The limits of detection for Rb1 and Rg3 obtained were 0.31 µg/mL and 0.33 µg/mL, respectively. The limits of quantification were 0.95 µg/mL and 1.01 µg/mL for Rb1 and Rg3, respectively. Consequently, the high performance liquid chromatography demonstrated the highly sensitive and accurate method for determination of Rb1 and Rg3 in Panax notoginseng.
Fourier domain preconditioned conjugate gradient algorithm for atmospheric tomography.
Yang, Qiang; Vogel, Curtis R; Ellerbroek, Brent L
2006-07-20
By 'atmospheric tomography' we mean the estimation of a layered atmospheric turbulence profile from measurements of the pupil-plane phase (or phase gradients) corresponding to several different guide star directions. We introduce what we believe to be a new Fourier domain preconditioned conjugate gradient (FD-PCG) algorithm for atmospheric tomography, and we compare its performance against an existing multigrid preconditioned conjugate gradient (MG-PCG) approach. Numerical results indicate that on conventional serial computers, FD-PCG is as accurate and robust as MG-PCG, but it is from one to two orders of magnitude faster for atmospheric tomography on 30 m class telescopes. Simulations are carried out for both natural guide stars and for a combination of finite-altitude laser guide stars and natural guide stars to resolve tip-tilt uncertainty.
Why do high-redshift galaxies show diverse gas-phase metallicity gradients?
NASA Astrophysics Data System (ADS)
Ma, Xiangcheng; Hopkins, Philip F.; Feldmann, Robert; Torrey, Paul; Faucher-Giguère, Claude-André; Kereš, Dušan
2017-04-01
Recent spatially resolved observations of galaxies at z ˜ 0.6-3 reveal that high-redshift galaxies show complex kinematics and a broad distribution of gas-phase metallicity gradients. To understand these results, we use a suite of high-resolution cosmological zoom-in simulations from the Feedback in Realistic Environments project, which include physically motivated models of the multiphase interstellar medium, star formation and stellar feedback. Our simulations reproduce the observed diversity of kinematic properties and metallicity gradients, broadly consistent with observations at z ˜ 0-3. Strong negative metallicity gradients only appear in galaxies with a rotating disc, but not all rotationally supported galaxies have significant gradients. Strongly perturbed galaxies with little rotation always have flat gradients. The kinematic properties and metallicity gradient of a high-redshift galaxy can vary significantly on short time-scales, associated with starburst episodes. Feedback from a starburst can destroy the gas disc, drive strong outflows and flatten a pre-existing negative metallicity gradient. The time variability of a single galaxy is statistically similar to the entire simulated sample, indicating that the observed metallicity gradients in high-redshift galaxies reflect the instantaneous state of the galaxy rather than the accretion and growth history on cosmological time-scales. We find weak dependence of metallicity gradient on stellar mass and specific star formation rate (sSFR). Low-mass galaxies and galaxies with high sSFR tend to have flat gradients, likely due to the fact that feedback is more efficient in these galaxies. We argue that it is important to resolve feedback on small scales in order to produce the diverse metallicity gradients observed.
Yu, Shan; Zuo, Xingang; Shen, Tao; Duan, Yiyuan; Mao, Zhengwei; Gao, Changyou
2018-05-01
Selective adhesion and migration of smooth muscle cells (SMCs) over fibroblasts (FIBs) is required to prevent adventitia fibrosis in vascular regeneration. In this study, a uniform cell-resisting layer of poly(ethylene glycol) (PEG) with a density gradient of azide groups was generated on a substrate by immobilizing two kinds of PEG molecules in a gradient manner. A density gradient of alkynyl-functionalized Val-Ala-Pro-Gly (VAPG) peptides was then prepared on the PEG layer via click chemistry. The VAPG density gradient was characterized by fluorescence imaging, revealing the gradual enhancement of the fluorescent intensity along the substrate direction. The adhesion and mobility of SMCs were selectively enhanced on the VAPG density gradient, leading to directional migration toward the higher peptide density (up to 84%). In contrast, the adhesion and mobility of FIBs were significantly weakened. The net displacement of SMCs also significantly increased compared with that on tissue culture polystyrene (TCPS) and that of FIBs on the gradient. The mitogen-activated protein kinase (MAPK) signaling pathways related to cell migration were studied, showing higher expressions of functional proteins from SMCs on the VAPG-modified surface in a density-dependent manner. For the first time the selective adhesion and directional migration of SMCs over FIBs was achieved by an elaborative design of a gradient surface, leading to a new insight in design of novel vascular regenerative materials. Selective cell adhesion and migration guided by regenerative biomaterials are extremely important for the regeneration of targeted tissues, which can avoid the drawbacks of incorrect and uncontrolled responses of tissue cells to implants. For example, selectivity of smooth muscle cells (SMCs) over fibroblasts (FIBs) is required to prevent adventitia fibrosis in vascular regeneration. Herein we prepare a uniform cell-repelling layer, on which SMCs-selective Val-Ala-Pro-Gly (VAPG) peptides are immobilized in a continuous manner. Selective adhesion and enhanced and directional migration of SMCs over FIBs are achieved by the interplay of cell-repelling layer and gradient SMCs-selective VAPG peptides, paving a new way for the design of novel vascular grafts with enhanced biological performance. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Albrecht, Sandra S; Gordon-Larsen, Penny
2014-09-01
Despite comparatively lower socioeconomic status (SES), immigrants tend to have lower body weight and weaker SES gradients relative to US-born individuals. Yet, it is unknown how changes in SES over the life-course relate to body weight in immigrants versus US-born individuals. We used longitudinal data from a nationally representative, diverse sample of 13 701 adolescents followed into adulthood to investigate whether associations between SES mobility categories (educational attainment reported by individuals as adults and by their parents during adolescence) and body mass index (BMI) measured in adulthood varied by immigrant generation. Weighted multivariable linear regression models were adjusted for age, sex, race/ethnicity and immigrant generation. Among first-generation immigrants, although parental education was not associated with adult BMI, an immigrant's own education attainment was inversely associated with BMI (β=-2.6 kg/m(2); SE=0.9, p<0.01). In addition, upward educational mobility was associated with lower adult mean BMI than remaining low SES (β=-2.5 kg/m(2); SE=1.2, p<0.05). In contrast, among US-born respondents, college education in adulthood did not attenuate the negative association between parental education and adult BMI. Although an SES gradient emerged in adulthood for immigrants, remaining low SES from adolescence to adulthood was not associated with loss of health advantage relative to US-born respondents of US-born parents of similar SES. Immigrants were able to translate higher SES in adulthood into a lower adult mean BMI regardless of childhood SES, whereas the consequences of lower childhood SES had a longer reach even among the upwardly mobile US born. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bussell, S J; Koch, D L; Hammer, D A
1995-01-01
Tracer diffusion coefficients of integral membrane proteins (IMPs) in intact plasma membranes are often much lower than those found in blebbed, organelle, and reconstituted membranes. We calculate the contribution of hydrodynamic interactions to the tracer, gradient, and rotational diffusion of IMPs in plasma membranes. Because of the presence of immobile IMPs, Brinkman's equation governs the hydrodynamics in plasma membranes. Solutions of Brinkman's equation enable the calculation of short-time diffusion coefficients of IMPs. There is a large reduction in particle mobilities when a fraction of them is immobile, and as the fraction increases, the mobilities of the mobile particles continue to decrease. Combination of the hydrodynamic mobilities with Monte Carlo simulation results, which incorporate excluded area effects, enable the calculation of long-time diffusion coefficients. We use our calculations to analyze results for tracer diffusivities in several different systems. In erythrocytes, we find that the hydrodynamic theory, when combined with excluded area effects, closes the gap between existing theory and experiment for the mobility of band 3, with the remaining discrepancy likely due to direct obstruction of band 3 lateral mobility by the spectrin network. In lymphocytes, the combined hydrodynamic-excluded area theory provides a plausible explanation for the reduced mobility of sIg molecules induced by binding concanavalin A-coated platelets. However, the theory does not explain all reported cases of "anchorage modulation" in all cell types in which receptor mobilities are reduced after binding by concanavalin A-coated platelets. The hydrodynamic theory provides an explanation of why protein lateral mobilities are restricted in plasma membranes and why, in many systems, deletion of the cytoplasmic tail of a receptor has little effect on diffusion rates. However, much more data are needed to test the theory definitively. We also predict that gradient and tracer diffusivities are the same to leading order. Finally, we have calculated rotational diffusion coefficients in plasma membranes. They decrease less rapidly than translational diffusion coefficients with increasing protein immobilization, and the results agree qualitatively with the limited experimental data available. PMID:7612825
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wazawa, Tetsuichi; CREST, JST, 4-1-8, Honcho, Kawaguchi, Saitama 332-0012; Sagawa, Takashi
2011-01-28
Research highlights: {yields} Translationally hyper-mobile water has been detected around actin filaments. {yields} Translationally hyper-mobile water is formed upon polymerization of actin. {yields} Low water viscosity was found around F-actin using fluorescence anisotropy. {yields} Formation of hyper-mobile water may explain endothermic actin polymerization. -- Abstract: This paper reports that water molecules around F-actin, a polymerized form of actin, are more mobile than those around G-actin or in bulk water. A measurement using pulse-field gradient spin-echo {sup 1}H NMR showed that the self-diffusion coefficient of water in aqueous F-actin solution increased with actin concentration by {approx}5%, whereas that in G-actin solutionmore » was close to that of pure water. This indicates that an F-actin/water interaction is responsible for the high self-diffusion of water. The local viscosity around actin was also investigated by fluorescence measurements of Cy3, a fluorescent dye, conjugated to Cys 374 of actin. The steady-state fluorescence anisotropy of Cy3 attached to F-actin was 0.270, which was lower than that for G-actin, 0.334. Taking into account the fluorescence lifetimes of the Cy3 bound to actin, their rotational correlation times were estimated to be 3.8 and 9.1 ns for F- and G-actin, respectively. This indicates that Cy3 bound to F-actin rotates more freely than that bound to G-actin, and therefore the local water viscosity is lower around F-actin than around G-actin.« less
Chen, Miao; Xia, Qinghai; Liu, Mousheng; Yang, Yaling
2011-01-01
A cloud-point extraction (CPE) method using Triton X-114 (TX-114) nonionic surfactant was developed for the extraction and preconcentration of propyl gallate (PG), tertiary butyl hydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT) from edible oils. The optimum conditions of CPE were 2.5% (v/v) TX-114, 0.5% (w/v) NaCl and 40 min equilibration time at 50 °C. The surfactant-rich phase was then analyzed by reversed-phase high-performance liquid chromatography with ultraviolet detection at 280 nm, using a gradient mobile phase consisting of methanol and 1.5% (v/v) acetic acid. Under the studied conditions, 4 synthetic phenolic antioxidants (SPAs) were successfully separated within 24 min. The limits of detection (LOD) were 1.9 ng mL(-1) for PG, 11 ng mL(-1) for TBHQ, 2.3 ng mL(-1) for BHA, and 5.9 ng mL(-1) for BHT. Recoveries of the SPAs spiked into edible oil were in the range 81% to 88%. The CPE method was shown to be potentially useful for the preconcentration of the target analytes, with a preconcentration factor of 14. Moreover, the method is simple, has high sensitivity, consumes much less solvent than traditional methods, and is environment-friendly. Practical Application: The method established in this article uses less organic solvent to extract SPAs from edible oils; it is simple, highly sensitive and results in no pollution to the environment.
Shameli, Seyed Mostafa; Glawdel, Tomasz; Ren, Carolyn L
2015-03-01
Counter-flow gradient electrofocusing allows the simultaneous concentration and separation of analytes by generating a gradient in the total velocity of each analyte that is the sum of its electrophoretic velocity and the bulk counter-flow velocity. In the scanning format, the bulk counter-flow velocity is varying with time so that a number of analytes with large differences in electrophoretic mobility can be sequentially focused and passed by a single detection point. Studies have shown that nonlinear (such as a bilinear) velocity gradients along the separation channel can improve both peak capacity and separation resolution simultaneously, which cannot be realized by using a single linear gradient. Developing an effective separation system based on the scanning counter-flow nonlinear gradient electrofocusing technique usually requires extensive experimental and numerical efforts, which can be reduced significantly with the help of analytical models for design optimization and guiding experimental studies. Therefore, this study focuses on developing an analytical model to evaluate the separation performance of scanning counter-flow bilinear gradient electrofocusing methods. In particular, this model allows a bilinear gradient and a scanning rate to be optimized for the desired separation performance. The results based on this model indicate that any bilinear gradient provides a higher separation resolution (up to 100%) compared to the linear case. This model is validated by numerical studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pure phase encode magnetic field gradient monitor.
Han, Hui; MacGregor, Rodney P; Balcom, Bruce J
2009-12-01
Numerous methods have been developed to measure MRI gradient waveforms and k-space trajectories. The most promising new strategy appears to be magnetic field monitoring with RF microprobes. Multiple RF microprobes may record the magnetic field evolution associated with a wide variety of imaging pulse sequences. The method involves exciting one or more test samples and measuring the time evolution of magnetization through the FIDs. Two critical problems remain. The gradient waveform duration is limited by the sample T(2)*, while the k-space maxima are limited by gradient dephasing. The method presented is based on pure phase encode FIDs and solves the above two problems in addition to permitting high strength gradient measurement. A small doped water phantom (1-3 mm droplet, T(1), T(2), T(2)* < 100 micros) within a microprobe is excited by a series of closely spaced broadband RF pulses each followed by FID single point acquisition. Two trial gradient waveforms have been chosen to illustrate the technique, neither of which could be measured by the conventional RF microprobe measurement. The first is an extended duration gradient waveform while the other illustrates the new method's ability to measure gradient waveforms with large net area and/or high amplitude. The new method is a point monitor with simple implementation and low cost hardware requirements.
Power and spectrally efficient M-ARY QAM schemes for future mobile satellite communications
NASA Technical Reports Server (NTRS)
Sreenath, K.; Feher, K.
1990-01-01
An effective method to compensate nonlinear phase distortion caused by the mobile amplifier is proposed. As a first step towards the future use of spectrally efficient modulation schemes for mobile satellite applications, we have investigated effects of nonlinearities and the phase compensation method on 16-QAM. The new method provides about 2 dB savings in power for 16-QAM operation with cost effective amplifiers near saturation and thereby promising use of spectrally efficient linear modulation schemes for future mobile satellite applications.
On Localized Vapor Pressure Gradients Governing Condensation and Frost Phenomena.
Nath, Saurabh; Boreyko, Jonathan B
2016-08-23
Interdroplet vapor pressure gradients are the driving mechanism for several phase-change phenomena such as condensation dry zones, interdroplet ice bridging, dry zones around ice, and frost halos. Despite the fundamental nature of the underlying pressure gradients, the majority of studies on these emerging phenomena have been primarily empirical. Using classical nucleation theory and Becker-Döring embryo formation kinetics, here we calculate the pressure field for all possible modes of condensation and desublimation in order to gain fundamental insight into how pressure gradients govern the behavior of dry zones, condensation frosting, and frost halos. Our findings reveal that in a variety of phase-change systems the thermodynamically favorable mode of nucleation can switch between condensation and desublimation depending upon the temperature and wettability of the surface. The calculated pressure field is used to model the length of a dry zone around liquid or ice droplets over a broad parameter space. The long-standing question of whether the vapor pressure at the interface of growing frost is saturated or supersaturated is resolved by considering the kinetics of interdroplet ice bridging. Finally, on the basis of theoretical calculations, we propose that there exists a new mode of frost halo that is yet to be experimentally observed; a bimodal phase map is developed, demonstrating its dependence on the temperature and wettability of the underlying substrate. We hope that the model and predictions contained herein will assist future efforts to exploit localized vapor pressure gradients for the design of spatially controlled or antifrosting phase-change systems.