Method for laser-based two-dimensional navigation system in a structured environment
Boultinghouse, Karlan D.; Schoeneman, J. Lee; Tise, Bertice L.
1989-01-01
A low power, narrow laser beam, generated by a laser carried by a mobile vehicle, is rotated about a vertical reference axis as the vehicle navigates within a structured environment. At least three stationary retroreflector elements are located at known positions, preferably at the periphery of the structured environment, with one of the elements having a distinctive retroreflection. The projected rotating beam traverses each retroreflector in succession, and the corresponding retroreflections are received at the vehicle and focussed on a photoelectric cell to generate corresponding electrical signals. The signal caused by the distinctive retroreflection serves as an angle-measurement datum. An angle encoder coupled to the apparatus rotating the projected laser beam provides the angular separation from this datum of the lines connecting the mobile reference axis to successive retroreflectors. This real-time angular data is utilized with the known locations of the retroreflectors to trigonometrically compute using three point resection, the exact real-time location of the mobile reference axis (hence the navigating vehicle) vis-a-vis the structured environment, e.g., in terms of two-dimensional Cartesian coordinates associated with the environment.
High mobility, dual layer, c-axis aligned crystalline/amorphous IGZO thin film transistor
NASA Astrophysics Data System (ADS)
Chung, Chen-Yang; Zhu, Bin; Greene, Raymond G.; Thompson, Michael O.; Ast, Dieter G.
2015-11-01
We demonstrate a dual layer IGZO thin film transistor (TFT) consisting of a 310 °C deposited c-axis aligned crystal (CAAC) 20 nm thick channel layer capped by a second, 30 nm thick, 260 °C deposited amorphous IGZO layer. The TFT exhibits a saturation field-effect mobility of ˜20 cm2/V s, exceeding the mobility of 50 nm thick single layer reference TFTs fabricated with either material. The deposition temperature of the second layer influences the mobility of the underlying transport layer. When the cap layer is deposited at room temperature (RT), the mobility in the 310 °C deposited CAAC layer is initially low (6.7 cm2/V s), but rises continuously with time over 58 days to 20.5 cm2/V s, i.e., to the same value as when the second layer is deposited at 260 °C. This observation indicates that the two layers equilibrate at RT with a time constant on the order of 5 × 106 s. An analysis based on diffusive transport indicates that the room temperature diffusivity must be of the order of 1 × 10-18 cm2 s-1 with an activation enthalpy EA < 0.2 eV for the mobility limiting species. The findings are consistent with a hypothesis that the amorphous layer deposited on top of the CAAC has a higher solubility for impurities and/or structural defects than the underlying nanocrystalline transport layer, and that the equilibration of the mobility limiting species is rate limited by hydrogen diffusion, whose known diffusivity fits these estimates.
Reliability of frames of reference used for tibial component rotation in total knee arthroplasty.
Page, Stephen R; Deakin, Angela H; Payne, Anthony P; Picard, Frederic
2011-01-01
This study evaluated seven different frames of reference used for tibial component rotation in total knee arthroplasty (TKA) to determine which ones showed good reliability between bone specimens. An optoelectronic system based around a computer-assisted surgical navigation system was used to measure and locate 34 individual anatomical landmarks on 40 tibias. Each particular frame of reference was reconstructed from a group of data points taken from the surface of each bone. The transverse axis was used as the baseline to which the other axes were compared, and the differences in angular rotation between the other six reference frames and the transverse axis were calculated. There was high variability in the tibial rotational alignment associated with all frames of reference. Of the references widely used in current TKA procedures, the tibial tuberosity axis and the anterior condylar axis had lower standard deviations (6.1° and 7.3°, respectively) than the transmalleolar axis and the posterior condylar axis (9.3° for both). In conclusion, we found high variability in the frames of reference used for tibial rotation alignment. However, the anterior condylar axis and transverse axis may warrant further tests with the use of navigation. Combining different frames of reference such as the tibial tuberosity axis, anterior condylar axis and transverse axis may reduce the range of errors found in all of these measurements.
Ikuta, N; Yamada, Y; Hirokawa, T
2000-01-01
For capillary zone electrophoresis, a new method of transformation from migration time to effective mobility was proposed, in which the mobility increase due to Joule heating and the relaxation effect of the potential gradient were eliminated successfully. The precision of the mobility evaluated by the proposed transformation was discussed in relation to the analysis of rare earth ions. By using the transformation, almost the same pherograms could be obtained even from the pherograms obtained originally at different applied voltages.
Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro
2015-05-01
A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1=ω2+ω3. This relation enabled to lay out the flow tube without twisting by the simultaneous rotation of three axes. The flow tube was introduced from the bottom side of the apparatus into the sun axis of the first rotary frame reaching the upper side of the planet axis and connected to the column in the satellite axis. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3:2:5, v/v) for lower phase mobile and (1:4:5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) - CCW (ω2) - CCW (ω3) by the flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) - CW (ω2) - CW (ω3) by the flow tube distribution. A series of experiments on peak resolution and stationary phase retention revealed that better partition efficiencies were obtained at the flow rate of 0.5 mL/min (column 1) and 0.8 mL/min (column 2) for lower phase mobile and 0.2 mL/min (column 1) and 0.4 mL/min (column 2) for upper phase mobile when using the left-handed multilayer coil (total capacity: 57.0 mL for column 1 and 75.0 mL for column 2) under the rotation speeds of approximately ω1=300 rpm, ω2=150 rpm and ω3=150 rpm. Copyright © 2015 Elsevier B.V. All rights reserved.
Can mobile phones used in strong motion seismology?
NASA Astrophysics Data System (ADS)
D'Alessandro, Antonino; D'Anna, Giuseppe
2013-04-01
Micro Electro-Mechanical Systems (MEMS) accelerometers are electromechanical devices able to measure static or dynamic accelerations. In the 1990s MEMS accelerometers revolutionized the automotive-airbag system industry and are currently widely used in laptops, game controllers and mobile phones. Nowadays MEMS accelerometers seems provide adequate sensitivity, noise level and dynamic range to be applicable to earthquake strong motion acquisition. The current use of 3 axes MEMS accelerometers in mobile phone maybe provide a new means to easy increase the number of observations when a strong earthquake occurs. However, before utilize the signals recorded by a mobile phone equipped with a 3 axes MEMS accelerometer for any scientific porpoise, it is fundamental to verify that the signal collected provide reliable records of ground motion. For this reason we have investigated the suitability of the iPhone 5 mobile phone (one of the most popular mobile phone in the world) for strong motion acquisition. It is provided by several MEMS devise like a three-axis gyroscope, a three-axis electronic compass and a the LIS331DLH three-axis accelerometer. The LIS331DLH sensor is a low-cost high performance three axes linear accelerometer, with 16 bit digital output, produced by STMicroelectronics Inc. We have tested the LIS331DLH MEMS accelerometer using a vibrating table and the EpiSensor FBA ES-T as reference sensor. In our experiments the reference sensor was rigidly co-mounted with the LIS331DHL MEMS sensor on the vibrating table. We assessment the MEMS accelerometer in the frequency range 0.2-20 Hz, typical range of interesting in strong motion seismology and earthquake engineering. We generate both constant and damped sine waves with central frequency starting from 0.2 Hz until 20 Hz with step of 0.2 Hz. For each frequency analyzed we generate sine waves with mean amplitude 50, 100, 200, 400, 800 and 1600 mg0. For damped sine waves we generate waveforms with initial amplitude of 2 g0. Our tests show as, in the frequency and amplitude range analyzed (0.2-20 Hz, 10-2000 mg0), the LIS331DLH MEMS accelerometer have excellent frequency and phase response, comparable with that of some standard FBA accelerometer used in strong motion seismology. However, we found that the signal recorded by the LIS331DLH MEMS accelerometer slightly underestimates the real acceleration (of about 2.5%). This suggests that may be important to calibrate a MEMS sensor before using it in scientific applications. A drawback of the LIS331DLH MEMS accelerometer is its low sensitivity. This is an important limitation of all the low cost MEMS accelerometers; therefore nowadays they are desirable to use only in strong motion seismology. However, the rapid development of this technology will lead in the coming years to the development of high sensitivity and low noise digital MEMS sensors that may be replace the current seismic accelerometer used in seismology. Actually, the real main advantage of these sensors is their common use in the mobile phones.
The Role of Mean-motion Resonances in Semimajor Axis Mobility of Asteroids
NASA Astrophysics Data System (ADS)
Milić Žitnik, Ivana; Novaković, Bojan
2016-01-01
Here, we report our findings about the effect of 11 two-body mean-motion resonances (MMRs) with Jupiter, on the mobility of an asteroid’s semimajor axis caused by the Yarkovsky effect. This study is accomplished using numerical integrations of test particles. The obtained results reveal that MMRs could either speed up or slow down the drift in the semimajor axis. Moreover, this allows us to determine the distribution that represents the best data obtained for time delays dtr caused by the resonances on the mobility of an asteroid. We also found a certain functional relationship that describes dependence of the average time lead/lag < {dtr}> on the strength of the resonance SR and the semimajor axis drift speed da/dt. As the Yarkovsky effect scales as 1/D, an important consequence of this relationship is that average time lead/lag < {dtr}> is directly proportional to the diameter D of an asteroid.
Awake craniotomy using electromagnetic navigation technology without rigid pin fixation.
Morsy, Ahmed A; Ng, Wai Hoe
2015-11-01
We report our institutional experience using an electromagnetic navigation system, without rigid head fixation, for awake craniotomy patients. The StealthStation® S7 AxiEM™ navigation system (Medtronic, Inc.) was used for this technique. Detailed preoperative clinical and neuropsychological evaluations, patient education and contrast-enhanced MRI (thickness 1.5mm) were performed for each patient. The AxiEM Mobile Emitter was typically placed in a holder, which was mounted to the operating room table, and a non-invasive patient tracker was used as the patient reference device. A monitored conscious sedation technique was used in all awake craniotomy patients, and the AxiEM Navigation Pointer was used for navigation during the procedure. This offers the same accuracy as optical navigation, but without head pin fixation or interference with intraoperative neurophysiological techniques and surgical instruments. The application of the electromagnetic neuronavigation technology without rigid head fixation during an awake craniotomy is accurate, and offers superior patient comfort. It is recommended as an effective adjunctive technique for the conduct of awake surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.
Steerable vertical to horizontal energy transducer for mobile robots
Spletzer, Barry L.; Fischer, Gary J.; Feddema, John T.
2001-01-01
The present invention provides a steerable vertical to horizontal energy transducer for mobile robots that less complex and requires less power than two degree of freedom tilt mechanisms. The present invention comprises an end effector that, when mounted with a hopping actuator, translates along axis (typically vertical) actuation into combined vertical and horizontal motion. The end effector, or foot, mounts with an end of the actuator that moves toward the support surface (typically a floor or the earth). The foot is shaped so that the first contact with the support surface is off the axis of the actuator. Off-axis contact with the support surface generates an on-axis force (typically resulting in vertical motion) and a moment orthogonal to the axis. The moment initiates a horizontal tumbling motion, and tilts the actuator so that its axis is oriented with a horizontal component and continued actuation generates both vertical and horizontal force.
Witoolkollachit, Polawat; Seubchompoo, Onuma
2008-07-01
The tibial axis referencing method with a balanced tension flexion gap at 90 degrees knee flexion provides adequate femoral component rotation usually in external rotation, the trans-epicondylar line being parallel to the proximal tibial cut. The LCS mobile bearing TKA uses this technique to automatically determine the femoral component rotation with desired tension. The determination of the epicondyles may lead to some confusion. On the lateral side, the prominence of the lateral condyle makes it easy to define. However on the medial side, some surgeons use the prominent part of the medial epicondyle (well recognized on CT scan as the most proximal ridge that gives insertion to the superficial collateral ligament) and use the anatomical transepicondylar axis (aTEA). Other surgeons use the depression below called sulcus that defines the surgical transepicondylar axis (sTEA). The authors evaluated 40 clinically successful mobile bearing TKA in 33 patients. All the knees were performed by single surgeon and the rotational alignment of the femoral component was applied with balanced flexion gap technique. Post-op CT-scans were done in all knees with 2-mm interval and measurement of the different angles (between aTEA and the prosthetic posterior condylar line and between the sTEA and the prosthetic posterior condylar line) with the UTHSCSA Imagetool (IT) version 3 from the University of Texas Health Science Center at San Antonio. The authors found that the mean femoral implant angle was in 2.39 degrees (SD = 2.80) of internal rotation with reference to the aTEA and in 1.34 degrees (SD = 1.57 degrees) of external rotation with reference to the sTEA when the medial sulcus was perfectly detected (nine knees, 22.5%). The angle between the aTEA and the sTEA was -3.98 degrees (SD = 1.05 degrees). No patella subluxation was identified. Nineteen or 47.5% of the femoral components were in internal or external femoral rotation of more than 3 degrees to the aTEA. When sTEA was detected, no knee was in internal or external rotation more than 3 degrees to sTEA. The balanced flexion gap technique positions the femoral component in external rotation with the LCS TKA. Within 3 degrees to aTEA or sTEA, this technique produced femoral rotational angle closer to sTEA when the sulcus was detected and produced a wide range of different angles when compared to aTEA. However sTEA is not the consistent bony landmark. This technique is a reliable method to determine femoral rotational alignment.
Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro
2015-01-01
A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1 = ω2 + ω3. This relation enabled to lay out the flow tube by two different ways, the SS type and the JS type. In the SS type, the flow tube was introduced from the upper side of the apparatus into the sun axis of the first rotary frame and connected to the planet axis of the second rotary frame like a double letter SS. In the JS type, the flow tube was introduced from the bottom of the apparatus into the sun axis reaching the upper side of the planet axis an inversed letter J, followed by distribution as in the SS type. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for lower phase mobile and (1 : 4 : 5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) – CCW (ω2) – CCW (ω3) by the JS type flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) – CW (ω2) – CW (ω3) by the JS type flow tube distribution. A series of experiments on peak resolution and stationary phase retention revealed that better partition efficiencies were obtained at the flow rate of 0.5 mL/min (column 1) and 0.8 mL/min (column 2) for lower phase mobile and 0.2 mL/min (column 1) and 0.4 mL/min (column 2) for upper phase mobile when using the left-handed multilayer coil (total capacity: 57.0 mL for column 1 and 75.0 mL for column 2) under the rotation speeds of approximately ω1 = 300 rpm, ω2 = 150 rpm and ω3 = 150 rpm. PMID:25805719
Off-axis illumination direct-to-digital holography
Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.
2004-06-08
Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.
Chang, Daniel H; Waring, George O
2014-11-01
To describe the inconsistencies in definition, application, and usage of the ocular reference axes (optical axis, visual axis, line of sight, pupillary axis, and topographic axis) and angles (angle kappa, lambda, and alpha) and to propose a precise, reproducible, clinically defined reference marker and axis for centration of refractive treatments and devices. Perspective. Literature review of papers dealing with ocular reference axes, angles, and centration. The inconsistent definitions and usage of the current ocular axes, as derived from eye models, limit their clinical utility. With a clear understanding of Purkinje images and a defined alignment of the observer, light source/fixation target, and subject eye, the subject-fixated coaxially sighted corneal light reflex can be a clinically useful reference marker. The axis formed by connecting the subject-fixated coaxially sighted corneal light reflex and the fixation point, the subject-fixated coaxially sighted corneal light reflex axis, is independent of pupillary dilation and phakic status of the eye. The relationship of the subject-fixated coaxially sighted corneal light reflex axis to a refined definition of the visual axis without reference to nodal points, the foveal-fixation axis, is discussed. The displacement between the subject-fixated coaxially sighted corneal light reflex and pupil center is described not by an angle, but by a chord, here termed chord mu. The application of the subject-fixated coaxially sighted corneal light reflex to the surgical centration of refractive treatments and devices is discussed. As a clinically defined reference marker, the subject-fixated coaxially sighted corneal light reflex avoids the shortcomings of current ocular axes for clinical application and may contribute to better consensus in the literature and improved patient outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.
Simple steep-axis marking technique using a corneal analyzer.
Ng, Alex L K; Chan, Tommy C Y; Jhanji, Vishal; Cheng, George P M
2017-02-01
We describe a simple steep-axis marking technique that uses a corneal analyzer (OPD III scan) during arcuate keratotomy in femtosecond laser-assisted cataract surgery. The technique requires a single reference mark at the limbus, which does not have to be on the horizontal axis. Using the corneal analyzer, the angle between the steep axis and the reference line between the reference mark and the center of the cornea can be determined. The angle from the reference mark is used intraoperatively to locate the steep axis. This eliminates the potential error from different head positions during keratometry measurement and during traditional marking under the slitlamp. The marking technique can also be applied to toric intraocular lens implantation during cataract surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Mohanraj, A. P.; Elango, A.; Reddy, Mutra Chanakya
2016-01-01
Omnidirectional robots can move in all directions without steering their wheels and it can rotate clockwise and counterclockwise with reference to their axis. In this paper, we focused only on front and back movement, to analyse the square- and triangle-structured omnidirectional robot movements. An omnidirectional mobile robot shows different performances with the different number of wheels and the omnidirectional mobile robot's chassis design. Research is going on in this field to improve the accurate movement capability of omnidirectional mobile robots. This paper presents a design of a unique device of Angle Variable Chassis (AVC) for linear movement analysis of a three-wheeled omnidirectional mobile robot (TWOMR), at various angles (θ) between the wheels. Basic mobility algorithm is developed by varying the angles between the two selected omnidirectional wheels in TWOMR. The experiment is carried out by varying the angles (θ = 30°, 45°, 60°, 90°, and 120°) between the two selected omniwheels and analysing the movement of TWOMR in forward direction and reverse direction on a smooth cement surface. Respectively, it is compared to itself for various angles (θ), to get its advantages and weaknesses. The conclusion of the paper provides effective movement of TWOMR at a particular angle (θ) and also the application of TWOMR in different situations. PMID:26981585
Mohanraj, A P; Elango, A; Reddy, Mutra Chanakya
2016-01-01
Omnidirectional robots can move in all directions without steering their wheels and it can rotate clockwise and counterclockwise with reference to their axis. In this paper, we focused only on front and back movement, to analyse the square- and triangle-structured omnidirectional robot movements. An omnidirectional mobile robot shows different performances with the different number of wheels and the omnidirectional mobile robot's chassis design. Research is going on in this field to improve the accurate movement capability of omnidirectional mobile robots. This paper presents a design of a unique device of Angle Variable Chassis (AVC) for linear movement analysis of a three-wheeled omnidirectional mobile robot (TWOMR), at various angles (θ) between the wheels. Basic mobility algorithm is developed by varying the angles between the two selected omnidirectional wheels in TWOMR. The experiment is carried out by varying the angles (θ = 30°, 45°, 60°, 90°, and 120°) between the two selected omniwheels and analysing the movement of TWOMR in forward direction and reverse direction on a smooth cement surface. Respectively, it is compared to itself for various angles (θ), to get its advantages and weaknesses. The conclusion of the paper provides effective movement of TWOMR at a particular angle (θ) and also the application of TWOMR in different situations.
Phase-field modeling of void anisotropic growth behavior in irradiated zirconium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, G. M.; Wang, H.; Lin, De-Ye
2017-06-01
A three-dimensional (3D) phase field model was developed to study the effects of surface energy and diffusivity anisotropy on void growth behavior in irradiated Zr. The gamma surface energy function, which is used in the phase field model, was developed with the surface energy anisotropy calculated from the molecular dynamics (MD) simulations. It is assumed that vacancies have much larger mobility in c-axis than a- and b- axes while interstitials have much larger mobility in basal plane then that in c-axis. With the model, the equilibrium void morphology and the effect of defect concentrations and defect mobility anisotropy on voidmore » growth behavior were simulated. The simulations demonstrated that 1) The developed phase-field model can correctly reproduce the faceted void morphology predicted by the Wullf construction. 2) With isotropic diffusivity the void prefers to grow on the basal plane. 3) When the vacancy has large mobility along c-axis and interstitial has a large mobility on the basal plane of hexagonal closed packed (hcp) Zr alloys a platelet void grows in c-direction and shrinks on the basal plane, which is in agreement with the experimental observation of void growth behavior in irradiated Zr.« less
Determination of a sagittal plane axis of rotation for a dynamic office chair.
Bauer, C M; Rast, F M; Böck, C; Kuster, R P; Baumgartner, D
2018-10-01
This study investigated the location of the axis of rotation in sagittal plane movement of the spine in a free sitting condition to adjust the kinematics of a mobile seat for a dynamic chair. Dynamic office chairs are designed to avoid continuous isometric muscle activity, and to facilitate increased mobility of the back during sitting. However, these chairs incorporate increased upper body movement which could distract office workers from the performance of their tasks. A chair with an axis of rotation above the seat would facilitate a stable upper back during movements of the lower back. The selection of a natural kinematic pattern is of high importance in order to match the properties of the spine. Twenty-one participants performed four cycles of flexion and extension of the spine during an upper arm hang on parallel bars. The location of the axis of rotation relative to the seat was estimated using infrared cameras and reflective skin markers. The median axis of rotation across all participants was located 36 cm above the seat for the complete movement and 39 cm for both the flexion and extension phases, each with an interquartile range of 20 cm. There was no significant effect of the movement direction on the location of the axis of rotation and only a weak, non-significant correlation between body height and the location of the axis of rotation. Individual movement patterns explained the majority of the variance. The axis of rotation for a spinal flexion/extension movement is located above the seat. The recommended radius for a guide rail of a mobile seat is between 36 cm and 39 cm. Copyright © 2018 Elsevier Ltd. All rights reserved.
Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi
2013-05-01
Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.
Umberger, D.K.; Osterman, L.E.; Smith, C.G.; Frazier, J.; Richwine, K.A.
2012-01-01
A study was undertaken in order to document and quantify recent environmental change in Mobile Bay, Alabama. The study was part of the Northern Gulf of Mexico (NGOM) Ecosystem Change and Hazard Susceptibility project, a regional project funded by the Coastal and Marine Geology Program to understand how natural forcings and anthropogenic modifications influence coastal ecosystems and their susceptibility to coastal hazards. Mobile Bay is a large drowned-river estuary that has been modified significantly by humans to accommodate the Port of Mobile. Examples include repeated dredging of a large shipping channel down the central axis of the bay and construction of a causeway across the head of the bay and at the foot of the bayhead delta. In addition to modifications, the bay is also known to have episodic periods of low oxygen (hypoxia) that result in significant mortality to fish and benthic organisms (May, 1973). For this study a series of surface sediment samples were collected. Surface benthic foraminiferal and bulk geochemical data provide the modern baseline conditions of the bay and can be used as a reference to changing environmental parameters in the past (Osterman and Smith, in press) and into the future. This report archives data collected as part of the Mobile Bay Study that may be used in future environmental change studies.
Acquisition and replay systems for direct-to-digital holography and holovision
Thomas, Clarence E.; Hanson, Gregory R.
2003-02-25
Improvements to the acquisition and replay systems for direct-to-digital holography and holovision are described. A method of recording an off-axis hologram includes: splitting a laser beam into an object beam and a reference beam; reflecting the reference beam from a reference beam mirror; reflecting the object beam from an illumination beamsplitter; passing the object beam through an objective lens; reflecting the object beam from an object; focusing the reference beam and the object beam at a focal plane of a digital recorder to form an off-axis hologram; digitally recording the off-axis hologram; and transforming the off-axis hologram in accordance with a Fourier transform to obtain a set of results. A method of writing an off-axis hologram includes: passing a laser beam through a spatial light modulator; and focusing the laser beam at a focal plane of a photorefractive crystal to impose a holographic diffraction grating pattern on the photorefractive crystal. A method of replaying an off-axis hologram includes: illuminating a photorefractive crystal having a holographic diffraction grating with a replay beam.
Mikrut, Sławomir; Kohut, Piotr; Pyka, Krystian; Tokarczyk, Regina; Barszcz, Tomasz; Uhl, Tadeusz
2016-01-01
The paper contains a survey of mobile scanning systems for measuring the railway clearance gauge. The research was completed as part of the project carried out for the PKP (PKP Polish Railway Lines S.A., Warsaw, Poland) in 2011–2013. The authors conducted experiments, including a search for the latest solutions relating to mobile measurement systems that meet the basic requirement. At the very least, these solutions needed to be accurate and have the ability for quick retrieval of data. In the paper, specifications and the characteristics of the component devices of the scanning systems are described. Based on experiments, the authors did some examination of the selected mobile systems to be applied for measuring the clearance gauge. The Riegl (VMX-250) and Z+F (Zoller + Fröhlich) Solution were tested. Additional test measurements were carried out within a 30-kilometer section of the Warsaw-Kraków route. These measurements were designed so as to provide various elements of the railway infrastructure, the track geometry and the installed geodetic control network. This ultimately made it possible to reduce the time for the preparation of geodetic reference measurements for the testing of the accuracy of the selected systems. Reference measurements included the use of the polar method to select profiles perpendicular to the axis of the track. In addition, the coordinates selected were well defined as measuring points of the objects of the infrastructure of the clearance gauge. All of the tested systems meet the accuracy requirements initially established (within the range of 2 cm as required by the PKP). The tested systems have shown their advantages and disadvantages. PMID:27187400
Content-based fused off-axis object illumination direct-to-digital holography
Price, Jeffery R.
2006-05-02
Systems and methods are described for content-based fused off-axis illumination direct-to-digital holography. A method includes calculating an illumination angle with respect to an optical axis defined by a focusing lens as a function of data representing a Fourier analyzed spatially heterodyne hologram; reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object the object beam incident upon the object at the illumination angle; focusing the reference beam and the object beam at a focal plane of a digital recorder to from the content-based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording the content based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
Smart and precise alignment of optical systems
NASA Astrophysics Data System (ADS)
Langehanenberg, Patrik; Heinisch, Josef; Stickler, Daniel
2013-09-01
For the assembly of any kind of optical systems the precise centration of every single element is of particular importance. Classically the precise alignment of optical components is based on the precise centering of all components to an external axis (usually a high-precision rotary spindle axis). Main drawback of this timeconsuming process is that it is significantly sensitive to misalignments of the reference (e.g. the housing) axis. In order to facilitate process in this contribution we present a novel alignment strategy for the TRIOPTICS OptiCentric® instrument family that directly aligns two elements with respect to each other by measuring the first element's axis and using this axis as alignment reference without the detour of considering an external reference. According to the optical design any axis in the system can be chosen as target axis. In case of the alignment to a barrel this axis is measured by using a distance sensor (e.g., the classically used dial indicator). Instead of fine alignment the obtained data is used for the calculation of its orientation within the setup. Alternatively, the axis of an optical element (single lens or group of lenses) whose orientation is measured with the standard OptiCentric MultiLens concept can be used as a reference. In the instrument's software the decentering of the adjusting element to the calculated axis is displayed in realtime and indicated by a target mark that can be used for the manual alignment. In addition, the obtained information can also be applied for active and fully automated alignment of lens assemblies with the help of motorized actuators.
Fiorina, Paolo; Jurewicz, Mollie; Vergani, Andrea; Petrelli, Alessandra; Carvello, Michele; D’Addio, Francesca; Godwin, Jonathan G.; Law, Kenneth; Wu, Erxi; Tian, Ze; Thoma, Gebhard; Kovarik, Jiri; La Rosa, Stefano; Capella, Carlo; Rodig, Scott; Zerwes, Hans-Guenter; Sayegh, Mohamed H.; Abdi, Reza
2012-01-01
Antagonism of CXCR4 disrupts the interaction between the CXCR4 receptor on HSCs and the CXCL12 expressed by stromal cells in the bone marrow, which subsequently results in the shedding of hematopoietic stem cells (HSCs) to the periphery. Due to their profound immunomodulatory effects, HSCs have emerged as a promising therapeutic strategy for autoimmune disorders. We sought to investigate the immunomodulatory role of mobilized autologous HSCs, via target of the CXCR4-CXL12 axis, to promote engraftment of islet cell transplantation. Islets from BALB/c mice were transplanted beneath the kidney capsule of hyperglycemic C57BL/6 mice, and treatment of recipients with CXCR4 antagonist resulted in mobilization of HSCs and in prolongation of islet graft survival. Addition of Rapamycin to anti-CXCR4 therapy further promoted HSC mobilization and islet allograft survival, inducing a robust and transferable host hyporesponsiveness, while administration of an ACK2 (anti-CD117) mAb halted CXCR4 antagonist-mediated HSC release and restored allograft rejection. Mobilized HSCs were shown to express high levels of the negative co-stimulatory molecule PD-L1, and HSCs extracted from WT mice, but not from PD-L1 KO, suppressed the in vitro alloimmune response. Moreover, HSC mobilization in PD-L1 KO mice failed to prolong islet allograft survival. Targeting the CXCR4-CXCL12 axis thus mobilizes autologous HSCs and promotes long-term survival of islet allografts via a PD-L1-mediated mechanism. PMID:21131428
Anisotropic charge transport in large single crystals of π-conjugated organic molecules.
Hourani, Wael; Rahimi, Khosrow; Botiz, Ioan; Koch, Felix Peter Vinzenz; Reiter, Günter; Lienerth, Peter; Heiser, Thomas; Bubendorff, Jean-Luc; Simon, Laurent
2014-05-07
The electronic properties of organic semiconductors depend strongly on the nature of the molecules, their conjugation and conformation, their mutual distance and the orientation between adjacent molecules. Variations of intramolecular distances and conformation disturb the conjugation and perturb the delocalization of charges. As a result, the mobility considerably decreases compared to that of a covalently well-organized crystal. Here, we present electrical characterization of large single crystals made of the regioregular octamer of 3-hexyl-thiophene (3HT)8 using a conductive-atomic force microscope (C-AFM) in air. We find a large anisotropy in the conduction with charge mobility values depending on the crystallographic orientation of the single crystal. The smaller conduction is in the direction of π-π stacking (along the long axis of the single crystal) with a mobility value in the order of 10(-3) cm(2) V(-1) s(-1), and the larger one is along the molecular axis (in the direction normal to the single crystal surface) with a mobility value in the order of 0.5 cm(2) V(-1) s(-1). The measured current-voltage (I-V) curves showed that along the molecular axis, the current followed an exponential dependence corresponding to an injection mode. In the π-π stacking direction, the current exhibits a space charge limited current (SCLC) behavior, which allows us to estimate the charge carrier mobility.
Experimental Testing of a Generic Submarine Model in the DSTO Low Speed Wind Tunnel. Phase 2
2014-03-01
axis, z-axis (Nm) l Model reference length (1.35 m) L Lift force (N) MRP Moment Reference Point q Dynamic pressure 2 2 1 Uρ (Pa...moment reference point ( MRP ). The moment reference point was defined as the mid-length position on the centre-line of the model. Figure 5 presents the
Muccifora, Simonetta; Guerranti, Roberto; Muzzi, Chiara; Hope-Onyekwere, Nnadozies S; Pagani, Roberto; Leoncini, Roberto; Bellani, Lorenza M
2010-03-01
The mobilization of storage reserves, with particular emphasis on storage proteins of Mucuna pruriens (L.) DC., cotyledons, and embryo was investigated from the ultrastructural and biochemical points of view. Proteins and starch were the two main storage substances in cotyledons, and proteins and lipids were the main ones in the embryo. Embryo protein bodies were smaller and fewer in number than those of cotyledons. Structural and ultrastructural data determined between 24 and 48 h after imbibition and between 48 and 72 h after imbibition, the end of significant embryo and cotyledon protein mobilization, respectively, indicating more precocious storage protein mobilization in the axis than cotyledons. Moreover, storage protein mobilization in embryo and cotyledons occurred before the end of germination. Water soluble proteins were separated by sodium dodecyl sulfate polyacrylamide gel electrophoresis, producing 29 bands with molecular weights from 14 to 90 KDa. Embryo extract contained more proteins than cotyledon extract, contained seven characteristic bands, and showed a higher variability of the optical density trend than cotyledon.
A new mobile phone-based ECG monitoring system.
Iwamoto, Junichi; Yonezawa, Yoshiharu; Ogawa, Hiromichi Maki Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton
2007-01-01
We have developed a system for monitoring a patient's electrocardiogram (ECG) and movement during daily activities. The complete system is mounted on chest electrodes and continuously samples the ECG and three axis accelerations. When the patient feels a heart discomfort, he or she pushes the data transmission switch on the recording system and the system sends the recorded ECG waveforms and three axis accelerations of the two prior minutes, and for two minutes after the switch is pressed. The data goes directly to a hospital server computer via a 2.4 GHz low power mobile phone. These data are stored on a server computer and downloaded to the physician's Java mobile phone. The physician can display the data on the phone's liquid crystal display.
Schiffman, Eric L.; Truelove, Edmond L.; Ohrbach, Richard; Anderson, Gary C.; John, Mike T.; List, Thomas; Look, John O.
2011-01-01
AIMS The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. An overview is presented, including Axis I and II methodology and descriptive statistics for the study participant sample. This paper details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. Validity testing for the Axis II biobehavioral instruments was based on previously validated reference standards. METHODS The Axis I reference standards were based on the consensus of 2 criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion exam reliability was also assessed within study sites. RESULTS Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas ≥ 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion exam agreement with reference standards was excellent (k ≥ 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). CONCLUSION The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods. PMID:20213028
Spacecraft attitude calibration/verification baseline study
NASA Technical Reports Server (NTRS)
Chen, L. C.
1981-01-01
A baseline study for a generalized spacecraft attitude calibration/verification system is presented. It can be used to define software specifications for three major functions required by a mission: the pre-launch parameter observability and data collection strategy study; the in-flight sensor calibration; and the post-calibration attitude accuracy verification. Analytical considerations are given for both single-axis and three-axis spacecrafts. The three-axis attitudes considered include the inertial-pointing attitudes, the reference-pointing attitudes, and attitudes undergoing specific maneuvers. The attitude sensors and hardware considered include the Earth horizon sensors, the plane-field Sun sensors, the coarse and fine two-axis digital Sun sensors, the three-axis magnetometers, the fixed-head star trackers, and the inertial reference gyros.
Johnson, Timothy J; Locascio, Laurie E
2002-08-01
Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a). two confluent streams in steady-state or (b). the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1). increasing the well depth, (2). decreasing the well angle relative to the axis of the channel, and (3). increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (microTAS) devices that are driven by electroosmosis.
Location memory biases reveal the challenges of coordinating visual and kinesthetic reference frames
Simmering, Vanessa R.; Peterson, Clayton; Darling, Warren; Spencer, John P.
2008-01-01
Five experiments explored the influence of visual and kinesthetic/proprioceptive reference frames on location memory. Experiments 1 and 2 compared visual and kinesthetic reference frames in a memory task using visually-specified locations and a visually-guided response. When the environment was visible, results replicated previous findings of biases away from the midline symmetry axis of the task space, with stability for targets aligned with this axis. When the environment was not visible, results showed some evidence of bias away from a kinesthetically-specified midline (trunk anterior–posterior [a–p] axis), but there was little evidence of stability when targets were aligned with body midline. This lack of stability may reflect the challenges of coordinating visual and kinesthetic information in the absence of an environmental reference frame. Thus, Experiments 3–5 examined kinesthetic guidance of hand movement to kinesthetically-defined targets. Performance in these experiments was generally accurate with no evidence of consistent biases away from the trunk a–p axis. We discuss these results in the context of the challenges of coordinating reference frames within versus between multiple sensori-motor systems. PMID:17703284
Izewska, Joanna; Georg, Dietmar; Bera, Pranabes; Thwaites, David; Arib, Mehenna; Saravi, Margarita; Sergieva, Katia; Li, Kaibao; Yip, Fernando Garcia; Mahant, Ashok Kumar; Bulski, Wojciech
2007-07-01
A strategy for national TLD audit programmes has been developed by the International Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for high-energy photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon and electron beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and asymmetric fields for photon beams. Through a co-ordinated research project the IAEA developed the methodology to extend the scope of national TLD auditing activities to more complex audit measurements for regular fields. Based on the IAEA standard TLD holder for high-energy photon beams, a TLD holder was developed with horizontal arm to enable measurements 5cm off the central axis. Basic correction factors were determined for the holder in the energy range between Co-60 and 25MV photon beams. New procedures were developed for the TLD irradiation in hospitals. The off-axis measurement methodology for photon beams was tested in a multi-national pilot study. The statistical distribution of dosimetric parameters (off-axis ratios for open and wedge beam profiles, output factors, wedge transmission factors) checked in 146 measurements was 0.999+/-0.012. The methodology of TLD audits in non-reference conditions with a modified IAEA TLD holder has been shown to be feasible.
New Trends on Mobile Learning in the Light of Recent Studies
ERIC Educational Resources Information Center
Korkmaz, Özgen
2015-01-01
Since the beginning of the century, with the introduction of mobile devices, use of the concept of mobile learning, became frequent, along with e-learning, m-learning, concept began to come on the agenda. It can be said that determining in what proportion and in which axis m-learning concept discussed in the literature would be important for…
Electron gun for a multiple beam klystron with magnetic compression of the electron beams
Ives, R. Lawrence; Tran, Hien T; Bui, Thuc; Attarian, Adam; Tallis, William; David, John; Forstall, Virginia; Andujar, Cynthia; Blach, Noah T; Brown, David B; Gadson, Sean E; Kiley, Erin M; Read, Michael
2013-10-01
A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.
Sacroiliac joint motion in patients with degenerative lumbar spine disorders.
Nagamoto, Yukitaka; Iwasaki, Motoki; Sakaura, Hironobu; Sugiura, Tsuyoshi; Fujimori, Takahito; Matsuo, Yohei; Kashii, Masafumi; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2015-08-01
OBJECT Usually additional anchors into the ilium are necessary in long fusion to the sacrum for degenerative lumbar spine disorders (DLSDs), especially for adult spine deformity. Although the use of anchors is becoming quite common, surgeons must always keep in mind that the sacroiliac (SI) joint is mobile and they should be aware of the kinematic properties of the SI joint in patients with DLSDs, including adult spinal deformity. No previous study has clarified in vivo kinematic changes in the SI joint with respect to patient age, sex, or parturition status or the presence of DLSDs. The authors conducted a study to clarify the mobility and kinematic characteristics of the SI joint in patients with DLSDs in comparison with healthy volunteers by using in vivo 3D motion analysis with voxel-based registration, a highly accurate, noninvasive method. METHODS Thirteen healthy volunteers (the control group) and 20 patients with DLSDs (the DLSD group) underwent low-dose 3D CT of the lumbar spine and pelvis in 3 positions (neutral, maximal trunk flexion, and maximal trunk extension). SI joint motion was calculated by computer processing of the CT images (voxel-based registration). 3D motion of the SI joint was expressed as both 6 df by Euler angles and translations on the coordinate system and a helical axis of rotation. The correlation between joint motion and the cross-sectional area of the trunk muscles was also investigated. RESULTS SI joint motion during trunk flexion-extension was minute in healthy volunteers. The mean rotation angles during trunk flexion were 0.07° around the x axis, -0.02° around the y axis, and 0.16° around the z axis. The mean rotation angles during trunk extension were 0.38° around the x axis, -0.08° around the y axis, and 0.08° around the z axis. During trunk flexion-extension, the largest amount of motion occurred around the x axis. In patients with DLSDs, the mean rotation angles during trunk flexion were 0.57° around the x axis, 0.01° around the y axis, and 0.19° around the z axis. The mean rotation angles during trunk extension were 0.68° around the x axis, -0.11° around the y axis, and 0.05° around the z axis. Joint motion in patients with DLSDs was significantly greater, with greater individual difference, than in healthy volunteers. Among patients with DLSDs, women had significantly more motion than men did during trunk extension. SI joint motion was significantly negatively correlated with the cross-sectional area of the trunk muscles during both flexion and extension of the trunk. CONCLUSIONS The authors elucidated the mobility and kinematic characteristics of the SI joint in patients with DLSDs compared with healthy volunteers for the first time. This information is useful for spine surgeons because of the recent increase in spinopelvic fusion for the treatment of DLSDs.
THE LIMITED EFFECT OF COINCIDENT ORIENTATION ON THE CHOICE OF INTRINSIC AXIS (.).
Li, Jing; Su, Wei
2015-06-01
The allocentric system computes and represents general object-to-object spatial relationships to provide a spatial frame of reference other than the egocentric system. The intrinsic frame-of-reference system theory, which suggests people learn the locations of objects based upon an intrinsic axis, is important in research about the allocentric system. The purpose of the current study was to determine whether the effect of coincident orientation on the choice of intrinsic axis was limited. Two groups of participants (24 men, 24 women; M age = 24 yr., SD = 2) encoded different spatial layouts in which the objects shared the coincident orientation of 315° and 225° separately at learning perspective (0°). The response pattern of partial-scene-recognition task following learning reflected different strategies for choosing the intrinsic axis under different conditions. Under the 315° object-orientation condition, the objects' coincident orientation was as important as the symmetric axis in the choice of the intrinsic axis. However, participants were more likely to choose the symmetric axis as the intrinsic axis under the 225° object-orientation condition. The results suggest the effect of coincident orientation on the choice of intrinsic axis is limited.
Methods for separating particles and/or nucleic acids using isotachophoresis
Jung, Byoungsok; Ness, Kevin; Rose, Klint A.
2016-03-15
According to one embodiment, a method includes co-feeding fluids comprising a leading electrolyte, a trailing electrolyte, and at least one of DNA and RNA to a channel, and applying an electric field to the fluids in a direction perpendicular to an axis of the channel for inducing transverse isotachophoresis. In another embodiment, a method includes co-feeding fluids to a channel. The fluids include a leading electrolyte, a trailing electrolyte, biological objects, at least one of DNA and RNA, and a spacer electrolyte having an electrophoretic mobility that is between an electrophoretic mobility of at least some of the biological objects and an electrophoretic mobility of the at least one of the DNA and the RNA. The method also includes applying an electric field to the fluids in a direction perpendicular to an axis of the channel for inducing transverse isotachophoresis. Other methods of isotachophoresis are disclosed in addition to these.
Evaluation of the Environmental Instruments, Incorporated Series 200 Dual Component Wind Set.
1980-09-01
elements is sensed to derive the sign (+ or -), which indicates the wind direction across the element pair. The reference arm of the Wheatstone bridge...Csine a for the crosswind axis, r and PF=a Vw Sine a for the headwind axis, r where Pa is the ambient air density, Pr is reference density at standard...pressure transducer is a hybrid linear silicon device which consists of a diaphragm and pressure reference , piezoresistive sensor, signal discriminator
Two spinning ways for precession dynamo.
Cappanera, L; Guermond, J-L; Léorat, J; Nore, C
2016-04-01
It is numerically demonstrated by means of a magnetohydrodynamic code that precession can trigger dynamo action in a cylindrical container. Fixing the angle between the spin and the precession axis to be 1/2π, two limit configurations of the spinning axis are explored: either the symmetry axis of the cylinder is parallel to the spin axis (this configuration is henceforth referred to as the axial spin case), or it is perpendicular to the spin axis (this configuration is referred to as the equatorial spin case). In both cases, the centro-symmetry of the flow breaks when the kinetic Reynolds number increases. Equatorial spinning is found to be more efficient in breaking the centro-symmetry of the flow. In both cases, the average flow in the reference frame of the mantle converges to a counter-rotation with respect to the spin axis as the Reynolds number grows. We find a scaling law for the average kinetic energy in term of the Reynolds number in the axial spin case. In the equatorial spin case, the unsteady asymmetric flow is shown to be capable of sustaining dynamo action in the linear and nonlinear regimes. The magnetic field is mainly dipolar in the equatorial spin case, while it is is mainly quadrupolar in the axial spin case.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
...'' include any line extending parallel to the central axis of the roller? Or, does this refer to the central... ``a longitudinal direction'' can include any line extending parallel to the central axis of the roller...) The finding that the Taylor reference (``A Telerobot on the World Wide Web'') (RX-281) does not...
Examining reference frame interaction in spatial memory using a distribution analysis.
Street, Whitney N; Wang, Ranxiao Frances
2016-02-01
Previous research showed competition among reference frames in spatial attention and language. The present studies developed a new distribution analysis to examine reference frame interactions in spatial memory. Participants viewed virtual arrays of colored pegs and were instructed to remember them either from their own perspective or from the perspective aligned with the rectangular floor. Then they made judgments of relative directions from their respective encoding orientation. Those taking the floor-axis perspective showed systematic bias in the signed errors toward their egocentric perspective, while those taking their own perspective showed no systematic bias, both for random and symmetrical object arrays. The bias toward the egocentric perspective was observed when learning a real symmetric regular object array with strong environmental cues for the aligned axis. These results indicate automatic processing of the self reference while taking the floor-axis perspective but not vice versa, and suggest that research on spatial memory needs to consider the implications of competition effects in reference frame use.
Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar
Gabella, Marco; Leuenberger, Andreas
2017-01-01
The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of −0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the “small” (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB. PMID:28531164
Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar.
Gabella, Marco; Leuenberger, Andreas
2017-05-22
The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of -0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the "small" (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB.
Kainz, Hans; Lloyd, David G; Walsh, Henry P J; Carty, Christopher P
2016-05-01
In motion analysis, pelvis angles are conventionally calculated as the rotations between the pelvis and laboratory reference frame. This approach assumes that the participant's motion is along the anterior-posterior laboratory reference frame axis. When this assumption is violated interpretation of pelvis angels become problematic. In this paper a new approach for calculating pelvis angles based on the rotations between the pelvis and an instantaneous progression reference frame was introduced. At every time-point, the tangent to the trajectory of the midpoint of the pelvis projected into the horizontal plane of the laboratory reference frame was used to define the anterior-posterior axis of the instantaneous progression reference frame. This new approach combined with the rotation-obliquity-tilt rotation sequence was compared to the conventional approach using the rotation-obliquity-tilt and tilt-obliquity-rotation sequences. Four different movement tasks performed by eight healthy adults were analysed. The instantaneous progression reference frame approach was the only approach that showed reliable and anatomically meaningful results for all analysed movement tasks (mean root-mean-square-differences below 5°, differences in pelvis angles at pre-defined gait events below 10°). Both rotation sequences combined with the conventional approach led to unreliable results as soon as the participant's motion was not along the anterior-posterior laboratory axis (mean root-mean-square-differences up to 30°, differences in pelvis angles at pre-defined gait events up to 45°). The instantaneous progression reference frame approach enables the gait analysis community to analysis pelvis angles for movements that do not follow the anterior-posterior axis of the laboratory reference frame. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wilde, C.; Langehanenberg, P.; Schenk, T.
2017-10-01
For modern production of micro lens systems, such as cementing of doublets or more lenses, precise centering of the lens edge is crucial. Blocking the lens temporarily on a centering arbor ensures that the centers of all optical lens surfaces coincide with the lens edge, while the arbor's axis serves as reference for both alignment and edging process. This theoretical assumption of the traditional cementing technology is not applicable for high-end production. In reality cement wedges between the bottom lens surface and the arbor's ring knife edge may occur and even expensive arbors with single-micron precision suffer from reduced quality of the ring knife edge after multiple usages and cleaning cycles. Consequently, at least the position of the bottom lens surface is undefined and the optical axis does not coincide with the arbor's reference axis! In order to overcome this basic problem in using centering arbors, we present a novel and efficient technique which can measure and align both surfaces of a lens with respect to the arbor axis with high accuracy and furthermore align additional lenses to the optical axis of the bottom lens. This is accomplished by aligning the lens without mechanical contact to the arbor. Thus the lens can be positioned in four degrees of freedom, while the centration errors of all lens surfaces are measured and considered. Additionally the arbor's reference axis is not assumed to be aligned to the rotation axis, but simultaneously measured with high precision.
Spherical Coordinate Systems for Streamlining Suited Mobility Analysis
NASA Technical Reports Server (NTRS)
Benson, Elizabeth; Cowley, Matthew S.; Harvill. Lauren; Rajulu, Sudhakar
2014-01-01
When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. One of our key functions is to help design engineers understand how a human will perform with new designs and all too often traditional use of Euler rotations becomes as much of a hindrance as a help. It is believed that using a spherical coordinate system will allow ABF personnel to more quickly and easily transmit important mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project is to establish new analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub-projects, meant to validate and verify the method before it was implemented in the ABF's data analysis practices. The first stage was a proof of concept, where a mechanical test rig was built and instrumented with an inclinometer, so that its angle from horizontal was known. The test rig was tracked in 3D using an optical motion capture system, and its position and orientation were reported in both Euler and spherical reference systems. The rig was meant to simulate flexion/extension, transverse rotation and abduction/adduction of the human shoulder, but without the variability inherent in human motion. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder, to include the torso, knees, ankle, elbows, wrists and neck. Part of this update included adding a representation of 'roll' about an axis, for upper arm and lower leg rotations. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. This visualization method will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development.
The punctum fixum-punctum mobile model: a neuromuscular principle for efficient movement generation?
von Laßberg, Christoph; Rapp, Walter
2015-01-01
According to the "punctum fixum-punctum mobile model" that was introduced in prior studies, for generation of the most effective intentional acceleration of a body part the intersegmental neuromuscular onset succession has to spread successively from the rotation axis (punctum fixum) toward the body part that shall be accelerated (punctum mobile). The aim of the present study was to investigate whether this principle is, indeed, fundamental for any kind of efficient rotational accelerations in general, independent of the kind of movements, type of rotational axis, the current body position, or movement direction. Neuromuscular onset succession was captured by surface electromyography of relevant muscles of the anterior and posterior muscle chain in 16 high-level gymnasts during intentional accelerating movement phases while performing 18 different gymnastics elements (in various body positions to forward and backward, performed on high bar, parallel bars, rings and trampoline), as well as during non-sport specific pivot movements around the longitudinal axis. The succession patterns to generate the acceleration phases during these movements were described and statistically evaluated based on the onset time difference between the muscles of the corresponding muscle chain. In all the analyzed movement phases, the results clearly support the hypothesized succession pattern from punctum fixum to punctum mobile. This principle was further underlined by the finding that the succession patterns do change their direction running through the body when the rotational axis (punctum fixum) has been changed (e.g., high bar or rings [hands] vs. floor or trampoline [feet]). The findings improve our understanding of intersegmental neuromuscular coordination patterns to generate intentional movements most efficiently. This could help to develop more specific methods to facilitate such patterns in particular contexts, thus allowing for shorter motor learning procedures of context-specific key movement sequences in different disciplines of sports, as well as during non-sport specific movements.
The Punctum Fixum-Punctum Mobile Model: A Neuromuscular Principle for Efficient Movement Generation?
von Laßberg, Christoph; Rapp, Walter
2015-01-01
According to the “punctum fixum–punctum mobile model” that was introduced in prior studies, for generation of the most effective intentional acceleration of a body part the intersegmental neuromuscular onset succession has to spread successively from the rotation axis (punctum fixum) toward the body part that shall be accelerated (punctum mobile). The aim of the present study was to investigate whether this principle is, indeed, fundamental for any kind of efficient rotational accelerations in general, independent of the kind of movements, type of rotational axis, the current body position, or movement direction. Neuromuscular onset succession was captured by surface electromyography of relevant muscles of the anterior and posterior muscle chain in 16 high-level gymnasts during intentional accelerating movement phases while performing 18 different gymnastics elements (in various body positions to forward and backward, performed on high bar, parallel bars, rings and trampoline), as well as during non-sport specific pivot movements around the longitudinal axis. The succession patterns to generate the acceleration phases during these movements were described and statistically evaluated based on the onset time difference between the muscles of the corresponding muscle chain. In all the analyzed movement phases, the results clearly support the hypothesized succession pattern from punctum fixum to punctum mobile. This principle was further underlined by the finding that the succession patterns do change their direction running through the body when the rotational axis (punctum fixum) has been changed (e.g., high bar or rings [hands] vs. floor or trampoline [feet]). The findings improve our understanding of intersegmental neuromuscular coordination patterns to generate intentional movements most efficiently. This could help to develop more specific methods to facilitate such patterns in particular contexts, thus allowing for shorter motor learning procedures of context-specific key movement sequences in different disciplines of sports, as well as during non-sport specific movements. PMID:25822498
2011-11-01
trajectory of the ship-fixed reference system relative to an earth-fixed reference system. The earth-fixed reference frame, EEE ZYX O , is assumed to be...the ship and moves with all the motions of the ship. The EEE ZYX O axis system is fixed to the earth. A third axis system, ’’’ zyxO , is required...added to account for the turbulence in the propeller slipstream: 2075.0445.0225.1 eeS aa radians for aeɛ.0 565.0S radians for ae
A daily living activity remote monitoring system for solitary elderly people.
Maki, Hiromichi; Ogawa, Hidekuni; Matsuoka, Shingo; Yonezawa, Yoshiharu; Caldwell, W Morton
2011-01-01
A daily living activity remote monitoring system has been developed for supporting solitary elderly people. The monitoring system consists of a tri-axis accelerometer, six low-power active filters, a low-power 8-bit microcontroller (MC), a 1GB SD memory card (SDMC) and a 2.4 GHz low transmitting power mobile phone (PHS). The tri-axis accelerometer attached to the subject's chest can simultaneously measure dynamic and static acceleration forces produced by heart sound, respiration, posture and behavior. The heart rate, respiration rate, activity, posture and behavior are detected from the dynamic and static acceleration forces. These data are stored in the SD. The MC sends the data to the server computer every hour. The server computer stores the data and makes a graphic chart from the data. When the caregiver calls from his/her mobile phone to the server computer, the server computer sends the graphical chart via the PHS. The caregiver's mobile phone displays the chart to the monitor graphically.
MIMO H∞ control of three-axis ship-mounted mobile antenna systems
NASA Astrophysics Data System (ADS)
Kuseyri, İ. Sina
2018-02-01
The need for on-line information in any environment has led to the development of mobile satellite communication terminals. These high data-rate terminals require inertial antenna pointing error tolerance within fractions of a degree. However, the base motion of the antenna platform in mobile applications complicates this pointing problem and must be accounted for. Gimbaled motorised pedestals are used to eliminate the effect of disturbance and maintain uninterrupted communication. In this paper, a three-axis ship-mounted antenna on a pedestal gimbal system is studied. Based on the derived dynamic model of the antenna pedestal multi input-multi output PID and H∞ linear controllers are designed to stabilise the antenna to keep its orientation unaltered towards the satellite while the sea waves disturb the antenna. Simulation results are presented to show the stabilisation performance of the system with the synthesised controllers. It is shown through performance comparison and analysis that the proposed H∞ control structure is preferable over PID controlled system in terms of system stability and the disturbance rejection.
Choun, Kimcheng; Achanta, Shanta; Naik, Balaji; Tripathy, Jaya Prasad; Thai, Sopheak; Lorent, Natalie; Khun, Kim Eam; van Griensven, Johan; Kumar, Ajay M V; Zachariah, Rony
2017-08-22
Over the last decade, the availability and use of mobile phones have grown exponentially globally and in Cambodia. In the Sihanouk Hospital Centre of Hope(SHCH) in Cambodia about half of all tuberculosis patients referred out to peripheral health facilities for TB treatment initiation or continuation were lost to contact after referral ranging from 19 to 69% between 2008 and 2013. To address this, we implemented a mobile phone-based patient tracking intervention. Here, we report the number and proportion of referred TB patients who could be contacted through a mobile phone and retained in care after the introduction of mobile phone tracking. A descriptive study involving follow-up of TB patients referred out from SHCH to peripheral health facilities during May-October 2014. Standard operating procedures were used to contact individual patients and/or health facilities using a mobile phone. Among 109 TB patients referred to peripheral health facilities, 107(98%) had access to a mobile phone of whom, 103(97%) could be contacted directly while 5(2%) were contacted through their health care providers. A total of 108(99%) of 109 referred TB patients in intervention period were thus placed on TB treatment. This study provides preliminary, but promising evidence that using mobile phones was accompanied with improved retention of referred TB patients compared to historical cohorts. Given the limitations associated with historical controls, we need better designed studies with larger sample size to strengthen the evidence before national scale-up.
Hydrodynamic mobility of a sphere moving on the centerline of an elastic tube
NASA Astrophysics Data System (ADS)
Daddi-Moussa-Ider, Abdallah; Lisicki, Maciej; Gekle, Stephan
2017-11-01
Elastic channels are an important component of many soft matter systems, in which hydrodynamic interactions with confining membranes determine the behavior of particles in flow. In this work, we derive analytical expressions for Green's functions associated with a point-force (Stokeslet) directed parallel or perpendicular to the axis of an elastic cylindrical channel exhibiting resistance against shear and bending. We then compute the leading order self- and pair mobility functions of particles on the cylinder axis, finding that the mobilities are primarily determined by membrane shear and that bending does not play a significant role. In the quasi-steady limit of vanishing frequency, the particle self- and pair mobilities near a no-slip hard cylinder are recovered only if the membrane possesses a non-vanishing shear rigidity. We further compute the membrane deformation, finding that deformation is generally more pronounced in the axial (radial) directions, for the motion along (perpendicular to) the cylinder centerline, respectively. Our analytical calculations for Green's functions in an elastic cylinder can serve as a fundamental building block for future studies and are verified by fully resolved boundary integral simulations where very good agreement is obtained.
Three-dimensional anthropometry of the adult face.
DOT National Transportation Integrated Search
1978-03-01
This study describes a new three-dimensional anatomical axis system based on four conventional anthropometrical face landmarks. Coincident as a coordinate (orthogonal) axis system, this reference system was developed to provide convenient orientation...
Schiffman, Eric L; Truelove, Edmond L; Ohrbach, Richard; Anderson, Gary C; John, Mike T; List, Thomas; Look, John O
2010-01-01
The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites. Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.
Mobile Transcripts and Intercellular Communication in Plants.
Saplaoura, E; Kragler, F
2016-01-01
Phloem serves as a highway for mobile signals in plants. Apart from sugars and hormones, proteins and RNAs are transported via the phloem and contribute to the intercellular communication coordinating growth and development. Different classes of RNAs have been found mobile and in the phloem exudate such as viral RNAs, small interfering RNAs (siRNAs), microRNAs, transfer RNAs, and messenger RNAs (mRNAs). Their transport is considered to be mediated via ribonucleoprotein complexes formed between phloem RNA-binding proteins and mobile RNA molecules. Recent advances in the analysis of the mobile transcriptome indicate that thousands of transcripts move along the plant axis. Although potential RNA mobility motifs were identified, research is still in progress on the factors triggering siRNA and mRNA mobility. In this review, we discuss the approaches used to identify putative mobile mRNAs, the transport mechanism, and the significance of mRNA trafficking. © 2016 Elsevier Inc. All rights reserved.
Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro
2017-01-20
Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω 1 ), the planet axis (ω 2 ) and the satellite axis (the central axis of the column) (ω 3 ) according to the following formula: ω 1 =ω 2 +ω 3 . Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3: 2: 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω 1 , ω 2 , ω 3 )=(300, 150, 150rpm), and (1:4:5, v/v) for the upper mobile phase at (300:100:200rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω 2 and ω 3 under the constant revolution speed at ω 1 =300rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω 2 and ω 3 , while with the upper mobile phase these two values were sensitively varied according to the different combination of ω 2 and ω 3 . For example, when ω 2 =147 or 200rpm is used, no stationary phase was retained in the coiled column while ω 2 =150rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω 1 , ω 2 , ω 3 )=(300, 300, 0rpm) or (300, 0, 300rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300rpm) with the upper mobile phase. At lower rotation speed of ω 1 =300rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω 3 ) than by the planetary motion (ω 2 ), or ω 3 >ω 2 . The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n-hexane/ethyl acetate/1-butanol/methanol/water system at different volume ratios. In the satellite motion at (ω 1 , ω 2 , ω 3 )=(300, 150, 150rpm), almost constant stationary phase retention was obtained with the lower mobile phase regardless of the hydrophobicity of the solvent system whereas the stationary phase retention varied according to the volume ratio of the two-phase solvent system for the upper mobile phase. However, stable stationary phase retention was observed with either phase used as the mobile phase. In order to analyze the acceleration acting on the coiled column, an acceleration sensor was set on the column holder by displacing the multilayer column. The combination of the rotation speeds at (300, 100, 200rpm) showed double loops in the acceleration track, whereas (300, 150, 150rpm) showed a single loop, and all other combinations showed, complex tracks. The overall results indicate that the satellite motion is seriously affected by the combination of rotation speeds and the hydrophobicity of the two-phase solvent system when the upper phase was used as the mobile phase for separation. Copyright © 2016 Elsevier B.V. All rights reserved.
Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro
2016-01-01
Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3) according to the following formula: ω1 = ω2 + ω3. Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω1, ω2, ω3) = (300, 150, 150 rpm), and (1 : 4 : 5, v/v) for the upper mobile phase at (300 : 100 : 200 rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω2 and ω3 under the constant revolution speed at ω1 = 300 rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω2 and ω3, while with the upper mobile phase these two values were sensitively varied according to the different combination of ω2 and ω3. For example, when ω2 = 147 or 200 rpm is used, no stationary phase was retained in the coiled column while ω2 = 150 rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω1, ω2, ω3) = (300, 300, 0 rpm) or (300, 0, 300 rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300 rpm) with the upper mobile phase. At lower rotation speed of ω1 = 300 rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω3) than by the planetary motion (ω2), or ω3 > ω2. The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n-hexane/ethyl acetate/1-butanol/methanol/water system at different volume ratios. In the satellite motion at (ω1, ω2, ω3) = (300, 150, 150 rpm), almost constant stationary phase retention was obtained with the lower mobile phase regardless of the hydrophobicity of the solvent system whereas the stationary phase retention varied according to the volume ratio of the two-phase solvent system for the upper mobile phase. However, stable stationary phase retention was observed with either phase used as the mobile phase. In order to analyze the acceleration acting on the coiled column, an acceleration sensor was set on the column holder by displacing the multilayer column. The combination of the rotation speeds at (300, 100, 200 rpm) showed double loops in the acceleration track, whereas (300, 150, 150 rpm) showed a single loop, and all other combinations showed, complex tracks. The overall results indicate that the satellite motion is seriously affected by the combination of rotation speeds and the hydrophobicity of the two-phase solvent system when the upper phase was used as the mobile phase for separation. PMID:28040269
Effect of gravito-inertial cues on the coding of orientation in pre-attentive vision.
Stivalet, P; Marendaz, C; Barraclough, L; Mourareau, C
1995-01-01
To see if the spatial reference frame used by pre-attentive vision is specified in a retino-centered frame or in a reference frame integrating visual and nonvisual information (vestibular and somatosensory), subjects were centrifuged in a non-pendular cabin and were asked to search for a target distinguishable from distractors by difference in orientation (Treisman's "pop-out" paradigm [1]). In a control condition, in which subjects were sitting immobilized but not centrifuged, this task gave an asymmetric search pattern: Search was rapid and pre-attentional except when the target was aligned with the horizontal retinal/head axis, in which case search was slow and attentional (2). Results using a centrifuge showed that slow/serial search patterns were obtained when the target was aligned with the subjective horizontal axis (and not with the horizontal retinal/head axis). These data suggest that a multisensory reference frame is used in pre-attentive vision. The results are interpreted in terms of Riccio and Stoffregen's "ecological theory" of orientation in which the vertical and horizontal axes constitute independent reference frames (3).
Cansiz, Mustafa; Abbasov, Teymuraz; Kurt, M Bahattin; Celik, A Recai
2018-03-01
In this study, radio frequency electromagnetic field exposure levels were measured on the main streets in the city center of Diyarbakır, Turkey. Measured electric field levels were plotted on satellite imagery of Diyarbakır and were compared with exposure guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Exposure measurements were performed in dense urban, urban and suburban areas each day for 7 consecutive days. The measurement system consisted of high precision and portable spectrum analyzer, three-axis electric field antenna, connection cable and a laptop which was used to record the measurement samples as a data logger. The highest exposure levels were detected for two places, which are called Diclekent and Batıkent. It was observed that the highest instantaneous electric field strength value for Batıkent was 7.18 V/m and for Diclekent was 5.81 V/m. It was statistically determined that the main contributor band to the total exposure levels was Universal Mobile Telecommunications System band. Finally, it was concluded that all measured exposure levels were lower than the reference levels recommended by ICNIRP for general public health.
Early carbon mobilization and radicle protrusion in maize germination.
Sánchez-Linares, Luis; Gavilanes-Ruíz, Marina; Díaz-Pontones, David; Guzmán-Chávez, Fernando; Calzada-Alejo, Viridiana; Zurita-Villegas, Viridiana; Luna-Loaiza, Viridiana; Moreno-Sánchez, Rafael; Bernal-Lugo, Irma; Sánchez-Nieto, Sobeida
2012-07-01
Considerable amounts of information is available on the complex carbohydrates that are mobilized and utilized by the seed to support early seedling development. These events occur after radicle has protruded from the seed. However, scarce information is available on the role of the endogenous soluble carbohydrates from the embryo in the first hours of germination. The present work analysed how the soluble carbohydrate reserves in isolated maize embryos are mobilized during 6-24 h of water imbibition, an interval that exclusively embraces the first two phases of the germination process. It was found that sucrose constitutes a very significant reserve in the scutellum and that it is efficiently consumed during the time in which the adjacent embryo axis is engaged in an active metabolism. Sucrose transporter was immunolocalized in the scutellum and in vascular elements. In parallel, a cell-wall invertase activity, which hydrolyses sucrose, developed in the embryo axis, which favoured higher glucose uptake. Sucrose and hexose transporters were active in the embryo tissues, together with the plasma membrane H(+)-ATPase, which was localized in all embryo regions involved in both nutrient transport and active cell elongation to support radicle extension. It is proposed that, during the initial maize germination phases, a net flow of sucrose takes place from the scutellum towards the embryo axis and regions that undergo elongation. During radicle extension, sucrose and hexose transporters, as well as H(+)-ATPase, become the fundamental proteins that orchestrate the transport of nutrients required for successful germination.
Coordination of multiple robot arms
NASA Technical Reports Server (NTRS)
Barker, L. K.; Soloway, D.
1987-01-01
Kinematic resolved-rate control from one robot arm is extended to the coordinated control of multiple robot arms in the movement of an object. The structure supports the general movement of one axis system (moving reference frame) with respect to another axis system (control reference frame) by one or more robot arms. The grippers of the robot arms do not have to be parallel or at any pre-disposed positions on the object. For multiarm control, the operator chooses the same moving and control reference frames for each of the robot arms. Consequently, each arm then moves as though it were carrying out the commanded motions by itself.
Analysis of Ejection Seat Stability Using Easy Program. Volume I.
1980-09-01
BODY AXiS FURCE COMPONENT. L ACTING ON THE AiRPLANc FROM THE CATAPULT (Ld) C ILA1(3) - PORT ONE X,Y,L AIRPLANE BODY AXIS TORQUE COMPONENTS C ACrINu...THE AIRPLANE (FT) C EAPI3) - EARTH TO AIRPLANc . EULER ANGLES (DEG) C SKPt3) - XtYZ EARTh POSITIGN VECTOR OF THE SEAT REFERENCE L POINT (FT) f- LST(3
Winship, I R; Wylie, D R
2001-11-01
The responses of neurons in the medial column of the inferior olive to translational and rotational optic flow were recorded from anaesthetized pigeons. Panoramic translational or rotational flowfields were produced by mechanical devices that projected optic flow patterns onto the walls, ceiling and floor of the room. The axis of rotation/translation could be positioned to any orientation in three-dimensional space such that axis tuning could be determined. Each neuron was assigned a vector representing the axis about/along which the animal would rotate/translate to produce the flowfield that elicited maximal modulation. Both translation-sensitive and rotation-sensitive neurons were found. For neurons responsive to translational optic flow, the preferred axis is described with reference to a standard right-handed coordinate system, where +x, +y and +z represent rightward, upward and forward translation of the animal, respectively (assuming that all recordings were from the right side of the brain). t(+y) neurons were maximally excited in response to a translational optic flowfield that results from self-translation upward along the vertical (y) axis. t(-y) neurons also responded best to translational optic flow along the vertical axis but showed the opposite direction preference. The two remaining groups, t(-x+z) and t(-x-z) neurons, responded best to translational optic flow along horizontal axes that were oriented 45 degrees to the midline. There were two types of neurons responsive to rotational optic flow: rVA neurons preferred rotation about the vertical axis, and rH135c neurons preferred rotation about a horizontal axis at 135 degrees contralateral azimuth. The locations of marking lesions indicated a clear topographical organization of the six response types. In summary, our results reinforce that the olivo-cerebellar system dedicated to the analysis of optic flow is organized according to a reference frame consisting of three approximately orthogonal axes: the vertical axis, and two horizontal axes oriented 45 degrees to either side the midline. Previous research has shown that the eye muscles, vestibular semicircular canals and postural control system all share a similar spatial frame of reference.
Regulatory frameworks for mobile medical applications.
Censi, Federica; Mattei, Eugenio; Triventi, Michele; Calcagnini, Giovanni
2015-05-01
A mobile application (app) is a software program that runs on mobile communication devices such as a smartphone. The concept of a mobile medical app has gained popularity and diffusion but its reference regulatory context has raised discussion and concerns. Theoretically, a mobile app can be developed and uploaded easily by any person or entity. Thus, if an app can have some effects on the health of the users, it is mandatory to identify its reference regulatory context and the applicable prescriptions.
Medical applications for pharmacists using mobile devices.
Aungst, Timothy Dy
2013-01-01
Mobile devices (eg, smartphones, tablet computers) have become ubiquitous and subsequently there has been a growth in mobile applications (apps). Concurrently, mobile devices have been integrated into health care practice due to the availability and quality of medical apps. These mobile medical apps offer increased access to clinical references and point-of-care tools. However, there has been little identification of mobile medical apps suitable for the practice of pharmacy. To address the shortage of recommendations of mobile medical apps for pharmacists in daily practice. Mobile medical apps were identified via the iTunes and Google Play Stores via the "Medical" app categories and key word searches (eg, drug information, medical calculators). In addition, reviews provided by professional mobile medical app review websites were used to identify apps. Mobile medical apps were included if they had been updated in the previous 3 months, were available in the US, used evidence-based information or literature support, had dedicated app support, and demonstrated stability. Exclusion criteria included apps that were not available in English, had advertisement bias, used nonreferenced sources, were available only via an institution-only subscription, and were web-based portals. Twenty-seven mobile apps were identified and reviewed that involved general pharmacy practice, including apps that involved drug references, clinical references, medical calculators, laboratory references, news and continuing medical education, and productivity. Mobile medical apps have a variety of features that are beneficial to pharmacy practice. Individual clinicians should consider several characteristics of these apps to determine which are suitable to incorporate into their daily practice.
Off-axis digital holographic microscopy with LED illumination based on polarization filtering.
Guo, Rongli; Yao, Baoli; Gao, Peng; Min, Junwei; Zhou, Meiling; Han, Jun; Yu, Xun; Yu, Xianghua; Lei, Ming; Yan, Shaohui; Yang, Yanlong; Dan, Dan; Ye, Tong
2013-12-01
A reflection mode digital holographic microscope with light emitting diode (LED) illumination and off-axis interferometry is proposed. The setup is comprised of a Linnik interferometer and a grating-based 4f imaging unit. Both object and reference waves travel coaxially and are split into multiple diffraction orders in the Fourier plane by the grating. The zeroth and first orders are filtered by a polarizing array to select orthogonally polarized object waves and reference waves. Subsequently, the object and reference waves are combined again in the output plane of the 4f system, and then the hologram with uniform contrast over the entire field of view can be acquired with the aid of a polarizer. The one-shot nature in the off-axis configuration enables an interferometric recording time on a millisecond scale. The validity of the proposed setup is illustrated by imaging nanostructured substrates, and the experimental results demonstrate that the phase noise is reduced drastically by an order of 68% when compared to a He-Ne laser-based result.
1981-01-31
geometric factor. For the low energy FSA detectors, the background counts must be subtracted from the measured (actual) counts before the geometric factor...and high energy) each provide a background measure - ment. The background counts for the low energy ESA (LE ESA) were subtracted from the other four LE...perpendicular to the spacecraft +X reference spin axis and 189.660 around from the +Z axis (with this angle measured from the +Z axis in the direction
NASA Astrophysics Data System (ADS)
Yong, J. S.; Ung, N. M.; Jamalludin, Z.; Malik, R. A.; Wong, J. H. D.; Liew, Y. M.; Ng, K. H.
2016-02-01
We investigated the dosimetric impact of applicator displacement on dose specification during high dose rate (HDR) Cobalt-60 (Co-60) brachytherapy for cervical cancer through a planning study. Eighteen randomly selected HDR full insertion plans were restrospectively studied. The tandem and ovoids were virtually shifted translationally and rotationally in the x-, y- and z-axis directions on the treatment planning system. Doses to reference points and volumes of interest in the plans with shifted applicators were compared with the original plans. The impact of dose displacement on 2D (point-based) and 3D (volume-based) treatment planning techniques was also assessed. A ±2 mm translational y-axis applicator shift and ±4° rotational x-axis applicator shift resulted in dosimetric changes of more than 5% to organs at risk (OAR) reference points. Changes to the maximum doses to 2 cc of the organ (D2cc) in 3D planning were statistically significant and higher than the reference points in 2D planning for both the rectum and bladder (p<0.05). Rectal D2cc was observed to be the most sensitive to applicator displacement among all dose metrics. Applicator displacement that is greater than ±2 mm translational y-axis and ±4° rotational x-axis resulted in significant dose changes to the OAR. Thus, steps must be taken to minimize the possibility of applicator displacement during brachytherapy.
Le Fort III Distraction With Internal vs External Distractors: A Cephalometric Analysis.
Robertson, Kevin J; Mendez, Bernardino M; Bruce, William J; McDonnell, Brendan D; Chiodo, Michael V; Patel, Parit A
2018-05-01
This study compares the change in midface position following Le Fort III advancement using either rigid external distraction (group 1) or internal distraction (group 2). We hypothesized that, with reference to right-facing cephalometry, internal distraction would result in increased clockwise rotation and inferior displacement of the midface. Le Fort III osteotomies and standardized distraction protocols were performed on 10 cadaveric specimens per group. Right-facing lateral cephalograms were traced and compared across time points to determine change in position at points orbitale, anterior nasal spine (ANS), A-point, and angle ANB. Institutional. Twenty cadaveric head specimens. Standard subcranial Le Fort III osteotomies were performed from a coronal approach and adequately mobilized. The specified distraction mechanism was applied and advanced by 15 mm. Changes of position were calculated at various skeletal landmarks: orbitale, ANS, A-point, and ANB. Group 1 demonstrated relatively uniform x-axis advancement with minimal inferior repositioning at the A-point, ANS, and orbitale. Group 2 demonstrated marked variation in x-axis advancement among the 3 points, along with a significant inferior repositioning and clockwise rotation of the midface ( P < .0001). External distraction resulted in more uniform advancement of the midface, whereas internal distraction resulted in greater clockwise rotation and inferior displacement. External distraction appears to provide increased vector control of the midface, which is important in creating a customized distraction plan based on the patient's individual occlusal and skeletal needs.
40 CFR 75.41 - Precision criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for the entire 30- to 90-day period. (9) The owner or operator shall provide two separate time series... time where the vertical axis represents the percentage difference between each paired hourly reading... monitoring system (or reference method) readings versus time where the vertical axis represents hourly...
40 CFR 75.41 - Precision criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for the entire 30- to 90-day period. (9) The owner or operator shall provide two separate time series... time where the vertical axis represents the percentage difference between each paired hourly reading... monitoring system (or reference method) readings versus time where the vertical axis represents hourly...
40 CFR 75.41 - Precision criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for the entire 30- to 90-day period. (9) The owner or operator shall provide two separate time series... time where the vertical axis represents the percentage difference between each paired hourly reading... monitoring system (or reference method) readings versus time where the vertical axis represents hourly...
40 CFR 75.41 - Precision criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for the entire 30- to 90-day period. (9) The owner or operator shall provide two separate time series... time where the vertical axis represents the percentage difference between each paired hourly reading... monitoring system (or reference method) readings versus time where the vertical axis represents hourly...
40 CFR 75.41 - Precision criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for the entire 30- to 90-day period. (9) The owner or operator shall provide two separate time series... time where the vertical axis represents the percentage difference between each paired hourly reading... monitoring system (or reference method) readings versus time where the vertical axis represents hourly...
Shinomiya, Kazufusa; Umezawa, Motoki; Seki, Manami; Nitta, Jun; Zaima, Kazumasa; Harikai, Naoki; Ito, Yoichiro
2016-12-01
Countercurrent chromatography (CCC) is liquid-liquid partition chromatography without using a solid support matrix. This technique requires further improvement of partition efficiency and shortening theseparation time. The locular multilayer coils modified with and without mixer glass beads were developed for the separation of proteins and 4-methylumbelliferyl (MU) sugar derivatives using the small-scale cross-axis coil planet centrifuge. Proteins were well separated from each other and the separation was improved at a low flow rate of the mobile phase. On the other hand, 4-MU sugar derivatives were sufficiently resolved with short separation time at a highflow rate of the mobile phase under satisfactory stationary phase retention. Effective separations were achieved using the locular multilayer coil for proteins with aqueous-aqueous polymer phase systems and for 4-MU sugar derivatives with organic-aqueous two-phase solvent systems by inserting a glass bead into each locule.
NASA Astrophysics Data System (ADS)
Frins, E.; Bobrowski, N.; Osorio, M.; Casaballe, N.; Belsterli, G.; Wagner, T.; Platt, U.
2014-12-01
In March 2012 the emissions of NO2 and SO2 from a power station located on the east side of Montevideo Bay (34° 53‧ 10″ S, 56° 11‧ 49″ W) were quantified by simultaneously using mobile and scanning multi-axis differential optical absorption spectroscopy (in the following mobile DOAS and scanning DOAS, respectively). The facility produces electricity by means of two technologies: internal combustion motors and steam generators. The motors are powered with centrifuged heavy oil and produce a maximum power of 80 MW approximately. The steam generators produce approximately 305 MW and are powered with heavy fuel oil. We compare the emissions obtained from the measured slant column densities (mobile DOAS and scanning DOAS) with the emissions estimated from fuel mass balance. On one occasion it was possible to distinguish between the two types of sources, observing two plumes with different SO2 and NO2 emission rates. During the period of the campaign the mean SO2 emission flux was determined to be 0.36 (±0.12) kg s-1 and 0.26 (±0.09) kg s-1 retrieved from mobile and scanning DOAS respectively, while the calculated SO2 flux from the sulphur content of the fuel was 0.34 (±0.03) kg s-1. The average NO2 flux calculated from mobile DOAS was determined to be 11 (±3) × 10-3 kg s-1. Using the scanning DOAS approach a mean NO2 flux of 5.4 (±1.7) × 10-3 kg s-1 was obtained, which is significantly lower than by the mobile measurements. The differences between the results of mobile MAX-DOAS measurements and scanning DOAS measurements are most probably caused by the variability and the limited knowledge of the wind speed and direction.
Mobile source reference material for activity data collection from the Emissions Inventory Improvement Program (EIIP). Provides complete methods for collecting key inputs to onroad mobile and nonroad mobile emissions models.
Respiratory metabolism in the embryonic axis of germinating pea seed exposed to cadmium.
Smiri, Moêz; Chaoui, Abdelilah; El Ferjani, Ezzedine
2009-02-15
Seeds of pea (Pisum sativum L.) were germinated for 5d by soaking in distilled water or 5mM cadmium nitrate. The relationships among cadmium stress, germination rate, changes in respiratory enzyme activities and carbohydrates mobilization were studied. Two cell fractions were obtained from embryonic axis: (1) mitochondria, used to determine enzyme activities of citric acid cycle and electron transport chain, and (2) soluble, to measure some enzyme activities involved in fermentation and pentose phosphate pathway. Activities of malate- and succinate-dehydrogenases (MDH, SDH) and NADH- and succinate-cytochrome c reductases (NCCR, SCCR) were rapidly inhibited, while cytochrome c oxidase (CCO) was unaltered by cadmium treatment. However, this stimulated the NADPH-generating enzyme activities of the pentose phosphate pathway, glucose-6-phosphate- and 6-phosphogluconate-dehydrogenases (G6PDH, 6PGDH), as well as enzyme activity of fermentation, alcohol dehydrogenase (ADH), with concomitant inhibition in the capacity of enzyme inactivator (INADH). Moreover, Cd restricted carbohydrate mobilization in the embryonic axis. Almost no glucose and less than 7% of control fructose and total soluble sugars were available in the embryo tissues after 5d of exposure to cadmium. Cotyledonary invertase isoenzyme activity was also inhibited by Cd. The results indicate that cadmium induces disorder in the resumption of respiration in germinating pea seeds. The contribution of Cd-stimulated alternative metabolic pathways to compensate for the failure in mitochondrial respiration is discussed in relation to the delay in seed germination and embryonic axis growth.
Off-axis low coherence digital holographic interferometry for quantitative phase imaging with an LED
NASA Astrophysics Data System (ADS)
Guo, Rongli; Wang, Fan; Hu, Xiaoying; Yang, Wenqian
2017-11-01
Off-axis digital holographic interferometry with the light source of a light emitting diode (LED) is presented and its application for quantitative phase imaging in a large range with low noise is demonstrated. The scheme is implemented in a grating based Mach-Zehnder interferometer. To achieve off-axis interferometry, firstly, the collimated beam emitted from an LED is diffracted into multiple orders by a grating and they are split into two copies by a beam splitter; secondly, in the object arm the zero order of one copy is filtered in the Fourier plane and is reshaped to illuminate the sample, while in the reference arm one of its first order of another copy is selected to serve as the reference beam, and then an off-axis hologram can be obtained at the image plane. The main advantage stemming from an LED illumination is its high spatial phase resolution, due to the subdued speckle effect. The off-axis geometry enables one-shot recording of the hologram in the millisecond scale. The utility of the proposed setup is illustrated with measurements of a resolution target and part of a wing of green-lacewing, and dynamic evaporation process of an ethanol film.
Mental rotation of tactile stimuli: using directional haptic cues in mobile devices.
Gleeson, Brian T; Provancher, William R
2013-01-01
Haptic interfaces have the potential to enrich users' interactions with mobile devices and convey information without burdening the user's visual or auditory attention. Haptic stimuli with directional content, for example, navigational cues, may be difficult to use in handheld applications; the user's hand, where the cues are delivered, may not be aligned with the world, where the cues are to be interpreted. In such a case, the user would be required to mentally transform the stimuli between different reference frames. We examine the mental rotation of directional haptic stimuli in three experiments, investigating: 1) users' intuitive interpretation of rotated stimuli, 2) mental rotation of haptic stimuli about a single axis, and 3) rotation about multiple axes and the effects of specific hand poses and joint rotations. We conclude that directional haptic stimuli are suitable for use in mobile applications, although users do not naturally interpret rotated stimuli in any one universal way. We find evidence of cognitive processes involving the rotation of analog, spatial representations and discuss how our results fit into the larger body of mental rotation research. For small angles (e.g., less than 40 degree), these mental rotations come at little cost, but rotations with larger misalignment angles impact user performance. When considering the design of a handheld haptic device, our results indicate that hand pose must be carefully considered, as certain poses increase the difficulty of stimulus interpretation. Generally, all tested joint rotations impact task difficulty, but finger flexion and wrist rotation interact to greatly increase the cost of stimulus interpretation; such hand poses should be avoided when designing a haptic interface.
Lim, Eugene Y; Lee, Chiang; Cai, Weidong; Feng, Dagan; Fulham, Michael
2007-01-01
Medical practice is characterized by a high degree of heterogeneity in collaborative and cooperative patient care. Fast and effective communication between medical practitioners can improve patient care. In medical imaging, the fast delivery of medical reports to referring medical practitioners is a major component of cooperative patient care. Recently, mobile phones have been actively deployed in telemedicine applications. The mobile phone is an ideal medium to achieve faster delivery of reports to the referring medical practitioners. In this study, we developed an electronic medical report delivery system from a medical imaging department to the mobile phones of the referring doctors. The system extracts a text summary of medical report and a screen capture of diagnostic medical image in JPEG format, which are transmitted to 3G GSM mobile phones.
Noels, Heidi; Zhou, Baixue; Tilstam, Pathricia V; Theelen, Wendy; Li, Xiaofeng; Pawig, Lukas; Schmitz, Corinna; Akhtar, Shamima; Simsekyilmaz, Sakine; Shagdarsuren, Erdenechimeg; Schober, Andreas; Adams, Ralf H; Bernhagen, Jürgen; Liehn, Elisa A; Döring, Yvonne; Weber, Christian
2014-06-01
The Cxcl12/Cxcr4 chemokine ligand/receptor axis mediates the mobilization of smooth muscle cell progenitors, driving injury-induced neointimal hyperplasia. This study aimed to investigate the role of endothelial Cxcr4 in neointima formation. β-Galactosidase staining using bone marrow x kinase (Bmx)-CreER(T2) reporter mice and double immunofluorescence revealed an efficient and endothelial-specific deletion of Cxcr4 in Bmx-CreER(T2+) compared with Bmx-CreER(T2-) Cxcr4-floxed apolipoprotein E-deficient (Apoe(-/-)) mice (referred to as Cxcr4(EC-KO)ApoE(-/-) and Cxcr4(EC-WT) ApoE(-/-), respectively). Endothelial Cxcr4 deficiency significantly increased wire injury-induced neointima formation in carotid arteries from Cxcr4(EC-KO)ApoE(-/-) mice. The lesions displayed a higher number of macrophages, whereas the smooth muscle cell and collagen content were reduced. This was associated with a significant reduction in reendothelialization and endothelial cell proliferation in injured Cxcr4(EC-KO)ApoE(-/-) carotids compared with Cxcr4(EC-WT)ApoE(-/-) controls. Furthermore, stimulation of human aortic endothelial cells with chemokine (C-X-C motif) ligand 12 (CXCL12) significantly enhanced their wound-healing capacity in an in vitro scratch assay, an effect that could be reversed with the CXCR4 antagonist AMD3100. Also, flow cytometric analysis showed a reduced mobilization of Sca1(+)Flk1(+)Cd31(+) and of Lin(-)Sca1(+) progenitors in Cxcr4(EC-KO) ApoE(-/-) mice after vascular injury, although Cxcr4 surface expression was unaltered. No differences could be detected in plasma concentrations of Cxcl12, vascular endothelial growth factor, sphingosine 1-phosphate, or Flt3 (fms-related tyrosine kinase 3) ligand, all cytokines with an established role in progenitor cell mobilization. Nonetheless, double immunofluorescence revealed a significant reduction in local endothelial Cxcl12 staining in injured carotids from Cxcr4(EC-KO)ApoE(-/-) mice. Endothelial Cxcr4 is crucial for efficient reendothelialization after vascular injury through endothelial wound healing and proliferation, and through the mobilization of Sca1(+)Flk1(+)Cd31(+) cells, often referred to as circulating endothelial progenitor cells. © 2014 American Heart Association, Inc.
He, Peiheng; Zhu, Qi; Zhang, Zhaohui; Zou, Xuenong; Xu, Dongliang
2013-01-01
To investigate relationship between the tibial mechanical axis and bony landmarks of the calf and foot by developing a new laser-calibrated position for radiography of the lower limb. A total of 120 volunteers were randomly divided into two groups. All subjects were marked with skin projection of the hypothetical axis of the calf on the frontal and sagittal planes. Radiographs of weight-bearing full-length lower-limb were obtained by the laser-calibrated positioning in the experimental group, and by the use of conventional technique in the control group. To consider the rotation of the calf, radiological features of the knee and ankle were investigated. The relationship between the tibial mechanical axis and the bony landmarks of the calf and foot were also measured. Anteroposterior view depicted a tangential projection on the superior/inferior tibiofibular syndesmosis and between lateral malleolus and talus in ankle mortise in the experimental group. Bony overlap on the superior/inferior tibiofibular syndesmosis and between lateral malleolus and talus was seen in control group. On the tangential projection, it also presented a clear wheel-like contour of the medial femoral condyle, but a partial overlap between medial femoral condyle and tibial plateau. The femoral joint angle between the connecting line at the lowest point of the medial and lateral femoral condyles and the tibial mechanical axis was 83.6° ± 2.49° in the experimental group and 85.3° ± 2.18° in the control group (P < 0.001). The tibial tubercle-axis distance from the center of the medial and middle one-third of the tibial tubercle to the tibial mechanical axis was 1.5 mm in the experimental group and 3.7 mm in the control group (P < 0.05). The malleoli-axis distance from the midpoint of the bimalleolar line joining the tips of the medial and lateral malleoli to the tibial mechanical axis was 1.9 mm in the experimental group and 6.9 mm in the control group (P < 0.001). Lateral view showed no difference between the tibial mechanical axis and the fibular reference line within two groups. In the new radiographic position, our data indicate that the hypothetical tibial mechanical axis and fibular reference line, obtained by marking the specified anatomic landmarks of the calf and foot, are located more closely to the tibial mechanical axis by correcting the rotation of the calf and foot during the radiography. On anteroposterior view, the tibial mechanical axis was approximately 2 mm medial to the center of the ankle. This indicates that the hypothetical tibial mechanical axis marked on the skin could be referred to guide the tibial osteotomy in total knee arthroplasty.
NASA Astrophysics Data System (ADS)
Matsuda, Shinpei; Kikuchi, Erumu; Yamane, Yasumasa; Okazaki, Yutaka; Yamazaki, Shunpei
2015-04-01
Field-effect transistors (FETs) with c-axis-aligned crystalline In-Ga-Zn-O (CAAC-IGZO) active layers have extremely low off-state leakage current. Exploiting this feature, we investigated the application of CAAC-IGZO FETs to LSI memories. A high on-state current is required for the high-speed operation of these LSI memories. The field-effect mobility μFE of a CAAC-IGZO FET is relatively low compared with the electron mobility of single-crystal Si (sc-Si). In this study, we measured and calculated the channel length L dependence of μFE for CAAC-IGZO and sc-Si FETs. For CAAC-IGZO FETs, μFE remains almost constant, particularly when L is longer than 0.3 µm, whereas that of sc-Si FETs decreases markedly as L shortens. Thus, the μFE difference between both FET types is reduced by miniaturization. This difference in μFE behavior is attributed to the different susceptibilities of electrons to phonon scattering. On the basis of this result and the extremely low off-state leakage current of CAAC-IGZO FETs, we expect high-speed LSI memories with low power consumption.
Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).
Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E
2015-08-01
To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.
Tool calibration system for micromachining system
Miller, Donald M.
1979-03-06
A tool calibration system including a tool calibration fixture and a tool height and offset calibration insert for calibrating the position of a tool bit in a micromachining tool system. The tool calibration fixture comprises a yokelike structure having a triangular head, a cavity in the triangular head, and a port which communicates a side of the triangular head with the cavity. Yoke arms integral with the triangular head extend along each side of a tool bar and a tool head of the micromachining tool system. The yoke arms are secured to the tool bar to place the cavity around a tool bit which may be mounted to the end of the tool head. Three linear variable differential transformer's (LVDT) are adjustably mounted in the triangular head along an X axis, a Y axis, and a Z axis. The calibration insert comprises a main base which can be mounted in the tool head of the micromachining tool system in place of a tool holder and a reference projection extending from a front surface of the main base. Reference surfaces of the calibration insert and a reference surface on a tool bar standard length are used to set the three LVDT's of the calibration fixture to the tool reference position. These positions are transferred permanently to a mastering station. The tool calibration fixture is then used to transfer the tool reference position of the mastering station to the tool bit.
Masalski, Marcin; Kipiński, Lech; Grysiński, Tomasz; Kręcicki, Tomasz
2016-05-30
Hearing tests carried out in home setting by means of mobile devices require previous calibration of the reference sound level. Mobile devices with bundled headphones create a possibility of applying the predefined level for a particular model as an alternative to calibrating each device separately. The objective of this study was to determine the reference sound level for sets composed of a mobile device and bundled headphones. Reference sound levels for Android-based mobile devices were determined using an open access mobile phone app by means of biological calibration, that is, in relation to the normal-hearing threshold. The examinations were conducted in 2 groups: an uncontrolled and a controlled one. In the uncontrolled group, the fully automated self-measurements were carried out in home conditions by 18- to 35-year-old subjects, without prior hearing problems, recruited online. Calibration was conducted as a preliminary step in preparation for further examination. In the controlled group, audiologist-assisted examinations were performed in a sound booth, on normal-hearing subjects verified through pure-tone audiometry, recruited offline from among the workers and patients of the clinic. In both the groups, the reference sound levels were determined on a subject's mobile device using the Bekesy audiometry. The reference sound levels were compared between the groups. Intramodel and intermodel analyses were carried out as well. In the uncontrolled group, 8988 calibrations were conducted on 8620 different devices representing 2040 models. In the controlled group, 158 calibrations (test and retest) were conducted on 79 devices representing 50 models. Result analysis was performed for 10 most frequently used models in both the groups. The difference in reference sound levels between uncontrolled and controlled groups was 1.50 dB (SD 4.42). The mean SD of the reference sound level determined for devices within the same model was 4.03 dB (95% CI 3.93-4.11). Statistically significant differences were found across models. Reference sound levels determined in the uncontrolled group are comparable to the values obtained in the controlled group. This validates the use of biological calibration in the uncontrolled group for determining the predefined reference sound level for new devices. Moreover, due to a relatively small deviation of the reference sound level for devices of the same model, it is feasible to conduct hearing screening on devices calibrated with the predefined reference sound level.
2011-09-01
magnetometer as the sensor, and the ACS controller. The magnetic control approach of NPSAT1 relies on favorable moments of inertia by optimum equipment...parallel with the HAAS rotational axis. To cancel the earth’s rotational effects, the turntable was tilted at -36.4° (accounts for the geocentric ...this initialization. 108 a. Gyro Bias Calibration from Three-Axis Magnetometer Measurements Reference [35] presents a real-time approach for gyro
Viking lander location and spin axis of Mars: determination from radio tracking data.
Michael, W H; Tolson, R H; Mayo, A P; Blackshear, W T; Kelly, G M; Cain, D L; Brenkle, J P; Shapiro, I I; Reasenberg, R D
1976-08-27
Radio tracking data from the Viking lander have been used to determine the lander position and the orientation of the spin axis of Mars. The areocentric coordinates of the lander are 22.27 degrees N, 48.00 degrees W, and 3389.5 kilometers from the center of mass; the spin axis orientation, referred to Earth's mean equator and equinox of 1950.0, is 317.35 degrees right ascension and 52.71 degrees declination.
Study of mobile satellite network based on GEO/LEO satellite constellation
NASA Astrophysics Data System (ADS)
Hu, Xiulin; Zeng, Yujiang; Wang, Ying; Wang, Xianhui
2005-11-01
Mobile satellite network with Inter Satellite Links (ISLs), which consists of non-geostationary satellites, has the characteristic of network topology's variability. This is a great challenge to the design and management of mobile satellite network. This paper analyzes the characteristics of mobile satellite network, takes multimedia Quality of Service (QoS) as the chief object and presents a reference model based on Geostationary Earth Orbit (GEO)/ Low Earth Orbit (LEO) satellite constellation which adapts to the design and management of mobile satellite network. In the reference model, LEO satellites constitute service subnet with responsibility for the access, transmission and switch of the multimedia services for mobile users, while GEO satellites constitute management subnet taking on the centralized management to service subnet. Additionally ground control centre realizes the whole monitoring and control via management subnet. Comparing with terrestrial network, the above reference model physically separates management subnet from service subnet, which not only enhances the advantage of centralized management but also overcomes the shortcoming of low reliability in terrestrial network. Routing of mobile satellite network based on GEO/LEO satellite constellation is also discussed in this paper.
Handler, Steven M.; Boyce, Richard D.; Ligons, Frank; Perera, Subashan; Nace, David A.; Hochheiser, Harry
2015-01-01
Objective Although mobile devices equipped with drug reference software may help prevent adverse drug events (ADEs) in the nursing home (NH) by providing medication information at the point-of-care, little is known about their use and perceived benefits. The goal of this study was to conduct a survey of a nationally representative sample of NH physicians to quantify the use and perceived benefits of mobile devices in preventing ADEs in the NH setting. Design/Setting/Participants We surveyed physicians who attended the 2010 the AMDA Annual Symposium about their use of mobile devices and beliefs about the effectiveness of drug reference software in preventing ADEs. Results The overall net valid response rate was 70% (558/800) with 42% (236/558) using mobile devices to assist with prescribing in the NH. Physicians with ≤15 years clinical experience were 67% more likely to be mobile device users, compared to those with >15 years of clinical experience (odds ratio=1.68; 95% confidence interval=1.17-2.41; p=0.005). For those who used a mobile device to assist with prescribing, almost all (98%) reported performing an average of one or more drug look-ups per day, performed an average of 1-2 lookups per day for potential drug-drug interactions (DDIs), and most (88%) believed that drug reference software had helped to prevent at least one potential ADE in the preceding four-week period. Conclusions The proportion of NH physicians who use mobile devices with drug reference software, while significant, is lower than in other clinical environments. Our results suggest that NH physicians who use mobile devices equipped with drug reference software believe they are helpful for reducing ADEs. Further research is needed to better characterize the facilitators and barriers to adoption of the technology in the NH and its precise impact on NH ADEs. PMID:24094901
Handler, Steven M; Boyce, Richard D; Ligons, Frank M; Perera, Subashan; Nace, David A; Hochheiser, Harry
2013-12-01
Although mobile devices equipped with drug reference software may help prevent adverse drug events (ADEs) in the nursing home (NH) by providing medication information at the point of care, little is known about their use and perceived benefits. The goal of this study was to conduct a survey of a nationally representative sample of NH physicians to quantify the use and perceived benefits of mobile devices in preventing ADEs in the NH setting. We surveyed physicians who attended the 2010 American Medical Directors Association Annual Symposium about their use of mobile devices, and beliefs about the effectiveness of drug reference software in preventing ADEs. The overall net valid response rate was 70% (558/800) with 42% (236/558) using mobile devices to assist with prescribing in the NH. Physicians with 15 or fewer years of clinical experience were 67% more likely to be mobile device users, compared with those with more than 15 years of clinical experience (odds ratio = 1.68; 95% confidence interval = 1.17-2.41; P = .005). For those who used a mobile device to assist with prescribing, almost all (98%) reported performing an average of 1 or more drug look-ups per day, performed an average of 1 to 2 lookups per day for potential drug-drug interactions (DDIs), and most (88%) believed that drug reference software had helped to prevent at least 1 potential ADE in the preceding 4-week period. The proportion of NH physicians who use mobile devices with drug reference software, although significant, is lower than in other clinical environments. Our results suggest that NH physicians who use mobile devices equipped with drug reference software believe they are helpful for reducing ADEs. Further research is needed to better characterize the facilitators and barriers to adoption of the technology in the NH and its precise impact on NH ADEs. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Tao, Donghua; McCarthy, Patrick G; Krieger, Mary M; Webb, Annie B
2009-01-01
The School of Public Health at Saint Louis University is located at a greater distance from the library than other programs on the main medical center campus. Physical distance diminishes the ease of access to direct reference services for public health users. To bridge the gap, the library developed the Mobile Reference Service to deliver on-site information assistance with regular office hours each week. Between September 2006 and April 2007, a total of 57 in-depth reference transactions took place over 25 weeks, averaging 2 transactions per week in a 2-hour period. Overall reference transactions from public health users went up 28%, while liaison contacts with public health users doubled compared to the same period the year before. The Mobile Reference Service program has improved library support for research and scholarship, cultivated and strengthened liaison relationships, and enhanced marketing and delivery of library resources and services to the Saint Louis University School of Public Health.
Tao, Donghua; McCarthy, Patrick G.; Krieger, Mary M.; Webb, Annie B.
2009-01-01
The School of Public Health at Saint Louis University is located at a greater distance from the library than other programs on the main medical center campus. Physical distance diminishes the ease of access to direct reference services for public health users. To bridge the gap, the library developed the Mobile Reference Service to deliver onsite information assistance with regular office hours each week. Between September 2006 and April 2007, a total of 57 in-depth reference transactions took place over 25 weeks, averaging 2 transactions per week in a 2-hour period. Overall reference transactions from public health users went up 28%, while liaison contacts with public health users doubled compared to the same period the year before. The Mobile Reference Service program has improved library support for research and scholarship, cultivated and strengthened liaison relationships, and enhanced marketing and delivery of library resources and services to the Saint Louis University School of Public Health. PMID:19159004
Miller, Jeffrey W; Diani, Art; Docsa, Steve; Ashton, Kristi; Sciamanna, Michele
2017-09-01
Percutaneous sacroplasty involves image-guided injection of bone cement for sacral insufficiency fractures to alleviate pain and facilitate mobility. Correct sacral placement of the cement and the risk of cement extravasation present procedural challenges. This study compares the occurrence, number, location, and surface area of high viscosity radiopaque bone cement extravasation via biplane fluoroscopy with Dyna CT between the fluoroscopically-guided intraoperative long-axis and short-axis sacroplasty techniques in osteoporotic cadavers. Ten osteoporotic cadavers underwent bilateral percutaneous instillation of VertaPlex HV High Viscosity Radiopaque Bone Cement. Long- and short-axis sacroplasty techniques were randomly assigned to zone 1 of the left or right sacral ala of each cadaver. Cement extravasation data were summarized by technique (long-axis vs short-axis) and time period (15-min and 3-hour post-procedure syngo DynaCT scan) in the form of point and CI estimates for the true proportions of cement extravasation. No procedural sacral extravasation differences were observed between the long-axis and short-axis sacroplasty techniques. There were no occurrences of intra-procedural or post-procedural cement extravasation at 15 min or 3 hours in association with either the long-axis sacroplasty technique or the short-axis sacroplasty technique. The long- and short-axis sacroplasty techniques, using high viscosity cement with careful post-procedural positioning, result in no occurrence of cement extravasation in porous osteoporotic cadaver bone. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
DOT National Transportation Integrated Search
2013-03-01
The Guide to Transportation Management Center (TMC) Data Capture for Performance and Mobility Measures is a two-volume document consisting of a summary Guidebook and this Reference Manual. These documents provide technical guidance and recommended pr...
Spherical Coordinate Systems for Streamlining Suited Mobility Analysis
NASA Technical Reports Server (NTRS)
Benson, Elizabeth; Cowley, Matthew; Harvill, Lauren; Rajulu. Sudhakar
2015-01-01
Introduction: When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. It has been shown that using a spherical coordinate system allows Anthropometry and Biomechanics Facility (ABF) personnel to increase their ability to transmit important human mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project was to use innovative analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub-projects, meant to validate and verify a new method before it was implemented in the ABF's data analysis practices. A mechanical test rig was built and tracked in 3D using an optical motion capture system. Its position and orientation were reported in both Euler and spherical reference systems. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder to include the rest of the joints of the body. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. These visualization methods will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development. Results: Initial results demonstrated that a spherical coordinate system is helpful in describing and visualizing the motion of a space suit. The system is particularly useful in describing the motion of the shoulder, where multiple degrees of freedom can lead to very complex motion paths.
NASA Astrophysics Data System (ADS)
Zhong, Chongquan; Lin, Yaoyao
2017-11-01
In this work, a model reference adaptive control-based estimated algorithm is proposed for online multi-parameter identification of surface-mounted permanent magnet synchronous machines. By taking the dq-axis equations of a practical motor as the reference model and the dq-axis estimation equations as the adjustable model, a standard model-reference-adaptive-system-based estimator was established. Additionally, the Popov hyperstability principle was used in the design of the adaptive law to guarantee accurate convergence. In order to reduce the oscillation of identification result, this work introduces a first-order low-pass digital filter to improve precision regarding the parameter estimation. The proposed scheme was then applied to an SPM synchronous motor control system without any additional circuits and implemented using a DSP TMS320LF2812. For analysis, the experimental results reveal the effectiveness of the proposed method.
Positional reference system for ultraprecision machining
Arnold, Jones B.; Burleson, Robert R.; Pardue, Robert M.
1982-01-01
A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.
Positional reference system for ultraprecision machining
Arnold, J.B.; Burleson, R.R.; Pardue, R.M.
1980-09-12
A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.
Pulse Power Hybrid Energy Storage Module Development Program
2015-05-01
consumed by the PFN. The energy stored in the HESM is displayed 12 as flywheel speed (RPM) against the right-side vertical axis . The flywheel speed...energy consumed by the PFN. The energy stored in the HESM is shown in Joules on the left-side vertical axis and in terms of flywheel speed (RPM) on the...right-side vertical axis . A noticeable difference in the charging variants is seen in the energy transfer through the HESM. Referring to Fig. 8, the
Implementation of Unsteady Double-Axis of Rotation Motion to Predict Pitch-Damping Moment
2016-10-18
2014;51(5). 4. Dupuis A. Aeroballistic range and wind tunnel tests of the basic finner reference projectile from subsonic to high supersonic velocities... modelled . Typically, when computing aerodynamic coefficients, motion about each axis is considered individually (i.e., spin around body-axis, pitch about...has a diameter, , of 0.03 m (1 caliber) and consists of a 10° half- angle cone that is 2.84-calibers long, followed by a 7.16-caliber cylindrical
Graf, Eveline S.; Wright, Ian C.; Stefanyshyn, Darren J.
2012-01-01
The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location. PMID:22666303
Langelaan, Saar; Bakker, Arnold B; Schaufeli, Wilmar B; van Rhenen, Willem; van Doornen, Lorenz J P
2006-10-01
The central aim of the present study was to examine differences in the functioning of the hypothalamic-pituitary-adrenal (HPA) axis between 29 burned-out, 33 work-engaged, and 26 healthy reference managers, as identified with the Maslach Burnout Inventory-General Survey and the Utrecht Work Engagement Scale. All of the managers were employed in a large Dutch telecommunications company. Salivary cortisol was sampled on three consecutive workdays and one nonworkday to determine the cortisol awakening response. Salivary dehydroepiandrosterone-sulfate (DHEAS), a cortisol counterbalancing product of the HPA axis, was measured on these days 1 hour after managers awakened. The dexamethasone suppression test was used to investigate the feedback sensitivity of the HPA axis. The morning cortisol levels were higher on the workdays than on the nonworkday, but this effect did not differ between the three groups. The burned-out, work-engaged, and reference groups did not differ in the cortisol and DHEAS levels, the slope of the cortisol awakening response, and the cortisol : DHEAS ratio. The work-engaged group showed a stronger cortisol suppression in response to the dexamethasone suppression test than the other two groups, the finding suggesting higher feedback sensitivity among work-engaged managers. Burned-out and work-engaged managers only differ marginally in HPA-axis functioning.
Transcendence, ethics, and Mobil Oil: a rhetorical investigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williamson, L.A.
1982-01-01
Since 1970 the Mobil Oil Corporation has been widely recognized as the self-appointed champion of corporate America's right to advocate. Corporate advocacy, as distinguished from other forms of external corporate communication, is concerned with the modification of corporate images and those social and political issues directly linked to the well-being of the corporation. Kenneth Burke's theory of transcendence serves as the central critical referent in the critique of Mobil's advocacy. By evoking elaborate transcendent frames of reference, Mobil seeks to identify its actions with higher syntheses that allow them to transcend the guilt produced by identifications with lesser orders. Mobilmore » evokes two ultimate frames which are recurrent in their transcendent identifications: American energy independence and freedom of expression. In the latter part of this investigation, Sidney Hook's ethics of controversy was offered as an ethical referent. Two levels of analysis were conducted: first, three major types of arguments against Mobil's advocacy were evaluated; second, Mobil's discourse was evaluated. The conclusion was reached that Mobil's advocacy is largely an ethical form of American democratic discourse. In the final section of this investigation, the heuristic values of this critique were discussed.« less
Zhang, Xu; Yang, Xiaodi; Geng, Hua; Nan, Guangjun; Sun, Xingwen; Xi, Jinyang; Xu, Xin
2015-05-05
Pentacene derivative 6,13-dichloropentacene (DCP) is one of the latest additions to the family of organic semiconductors with a great potential for use in transistors. We carry out a detailed theoretical calculation for DCP, with systematical comparison to pentacene, pentathienoacene (PTA, the thiophene equivalent of pentacene), to gain insights in the theoretical design of organic transport materials. The charge transport parameters and carrier mobilities are investigated from the first-principles calculations, based on the widely used Marcus electron transfer theory and quantum nuclear tunneling model, coupled with random walk simulation. Molecular structure and the crystal packing type are essential to understand the differences in their transport behaviors. With the effect of molecule modification, significant one-dimensional π-stacks are found within the molecular layer in PTA and DCP crystals. The charge transport along the a-axis plays a dominant role for the carrier mobilities in the DCP crystal due to the strong transfer integrals within the a-axis. Pentacene shows a relatively large 3D mobility. This is attributed to the relatively uniform electronic couplings, which thus provides more transport pathways. PTA has a much smaller 3D mobility than pentacene and DCP for the obvious increase of the reorganization energy with the introduction of thiophene. It is found that PTA and DCP exhibit lower HOMO (highest occupied molecular orbital) levels and better environmental stability, indicating the potential applications in organic electronics. © 2015 Wiley Periodicals, Inc.
Finite-time tracking control for multiple non-holonomic mobile robots based on visual servoing
NASA Astrophysics Data System (ADS)
Ou, Meiying; Li, Shihua; Wang, Chaoli
2013-12-01
This paper investigates finite-time tracking control problem of multiple non-holonomic mobile robots via visual servoing. It is assumed that the pinhole camera is fixed to the ceiling, and camera parameters are unknown. The desired reference trajectory is represented by a virtual leader whose states are available to only a subset of the followers, and the followers have only interaction. First, the camera-objective visual kinematic model is introduced by utilising the pinhole camera model for each mobile robot. Second, a unified tracking error system between camera-objective visual servoing model and desired reference trajectory is introduced. Third, based on the neighbour rule and by using finite-time control method, continuous distributed cooperative finite-time tracking control laws are designed for each mobile robot with unknown camera parameters, where the communication topology among the multiple mobile robots is assumed to be a directed graph. Rigorous proof shows that the group of mobile robots converges to the desired reference trajectory in finite time. Simulation example illustrates the effectiveness of our method.
Shinomiya, Kazufusa; Umezawa, Motoki; Seki, Manami; Nitta, Jun; Zaima, Kazumasa; Harikai, Naoki; Ito, Yoichiro
2016-01-01
1) Background Countercurrent chromatography (CCC) is liquid-liquid partition chromatography without using a solid support matrix. This technique requires further improvement of partition efficiency and shortening theseparation time. 2) Methods The locular multilayer coils modified with and without mixer glass beads were developed for the separation of proteins and 4-methylumbelliferyl (MU) sugar derivatives using the small-scale cross-axis coil planet centrifuge. 3) Results Proteins were well separated from each other and the separation was improved at a low flow rate of the mobile phase. On the other hand, 4-MU sugar derivatives were sufficiently resolved with short separation time at a highflow rate of the mobile phase under satisfactory stationary phase retention. 4) Conclusion Effective separations were achieved using the locular multilayer coil for proteins with aqueous-aqueous polymer phase systems and for 4-MU sugar derivatives with organic-aqueous two-phase solvent systems by inserting a glass bead into each locule. PMID:27891507
Research of misalignment between dithered ring laser gyro angle rate input axis and dither axis
NASA Astrophysics Data System (ADS)
Li, Geng; Wu, Wenqi; FAN, Zhenfang; LU, Guangfeng; Hu, Shaomin; Luo, Hui; Long, Xingwu
2014-12-01
The strap-down inertial navigation system (SINS), especially the SINS composed by dithered ring laser gyroscope (DRLG) is a kind of equipment, which providing high reliability and performance for moving vehicles. However, the mechanical dither which is used to eliminate the "Lock-In" effect can cause vibration disturbance to the INS and lead to dithering coupling problem in the inertial measurement unit (IMU) gyroscope triad, so its further application is limited. Among DRLG errors between the true gyro rotation rate and the measured rotation rate, the frequently considered one is the input axis misalignment between input reference axis which is perpendicular to the mounting surface and gyro angular rate input axis. But the misalignment angle between DRLG dither axis and gyro angular rate input axis is often ignored by researchers, which is amplified by dither coupling problem and that would lead to negative effects especially in high accuracy SINS. In order to study the problem more clearly, the concept of misalignment between DRLG dither axis and gyro angle rate input axis is researched. Considering the error of misalignment is of the order of 10-3 rad. or even smaller, the best way to measure it is using DRLG itself by means of an angle exciter as an auxiliary. In this paper, the concept of dither axis misalignment is explained explicitly firstly, based on this, the frequency of angle exciter is induced as reference parameter, when DRLG is mounted on the angle exciter in a certain angle, the projections of angle exciter rotation rate and mechanical oscillation rate on the gyro input axis are both sensed by DRLG. If the dither axis has misalignment error with the gyro input axis, there will be four major frequencies detected: the frequency of angle exciter, the dither mechanical frequency, sum and difference frequencies of the former two frequencies. Then the amplitude spectrum of DRLG output signal obtained by the using LabVIEW program. if there are only angle exciter and the dither mechanical frequencies, the misalignment may be too small to be detected, otherwise, the amplitude of the sum and difference frequencies will show the misalignment angle between the gyro angle rate input axis and the dither axis. Finally, some related parameters such as frequency and amplitude of the angle exciter and sample rate are calculated and the results are analyzed. The simulation and experiment result prove the effectiveness of the proposed method..
46 CFR 108.101 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Incorporation by reference. 108.101 Section 108.101 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN....105. Resolution A.649(16), Code for the Construction and Equipment of Mobile Offshore Drilling Units...
46 CFR 108.101 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Incorporation by reference. 108.101 Section 108.101 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN....105. Resolution A.649(16), Code for the Construction and Equipment of Mobile Offshore Drilling Units...
Weitoft, T; Rönnblom, L
2006-01-01
Background Studies have shown that intra‐articular glucocorticoid injection treatment for knee synovitis has a better outcome in resting patients than in mobile patients. One reason for this observation might be that rest retards steroid resorption, causing an enhanced local treatment effect. Objectives To study drug resorption and the impact on hormone production in the hypothalamic‐pituitary‐adrenal axis after intra‐articular glucocorticoid administration, with and without postinjection rest. Methods Twenty patients with rheumatoid arthritis and knee synovitis were randomised to either 24 hour bed rest or normal activity after intra‐articular glucocorticoid treatment with 20 mg triamcinolone hexacetonide (THA). Serum levels of THA, cortisol, and adrenocorticotropic hormone (ACTH) were followed during 2 weeks. Results Short term and reversible decreases in serum cortisol and ACTH levels (p<0.001) were seen, without any significant differences between resting and mobile patients. The THA levels increased similarly in both groups, with the median serum peak seen after 8 hours. Conclusion Immobilisation does not appear to retard glucocorticoid resorption after intra‐articular administration. Further studies are therefore needed to clarify the mechanism behind the beneficial effects of rest after intra‐articular glucocorticoid treatment for knee synovitis. PMID:16769782
Karpova, Darja; Ritchey, Julie K; Holt, Matthew S; Abou-Ezzi, Grazia; Monlish, Darlene; Batoon, Lena; Millard, Susan; Spohn, Gabriele; Wiercinska, Eliza; Chendamarai, Ezhil; Yang, Wei; Christ, Stephanie; Gehrs, Leah; Schuettpelz, Laura G; Dembowsky, Klaus; Pettit, Allison R; Rettig, Michael P; Bonig, Halvard; DiPersio, John F
2017-05-25
Interaction between the chemokine receptor CXCR4 and its chief ligand CXCL12 plays a critical role in the retention and migration of hematopoietic stem and progenitor cells (HSPCs) in the bone marrow (BM) microenvironment. In this study, qualitative and quantitative effects of long-term pharmacologic inhibition of the CXCR4/CXCL12 axis on the HSPC compartment were investigated by using 3 structurally unrelated small molecule CXCR4 antagonists. A >10-fold increase in mobilization efficiency was achieved by administering the antagonists as a subcutaneous continuous infusion for 2 weeks compared to a single bolus injection. A concurrent increase in self-renewing proliferation leading to a twofold to fourfold expansion of the HSPC pool in the BM was observed. The expanded BM showed a distinct repopulating advantage when tested in serial competitive transplantation experiments. Furthermore, major changes within the HSPC niche associated with previously described HSPC expansion strategies were not detected in bones treated with a CXCR4 antagonist infusion. Our data suggest that prolonged but reversible pharmacologic blockade of the CXCR4/CXCL12 axis represents an approach that releases HSPC with efficiency superior to any other known mobilization strategy and may also serve as an effective method to expand the BM HSPC pool. © 2017 by The American Society of Hematology.
Karpova, Darja; Ritchey, Julie K.; Holt, Matthew S.; Abou-Ezzi, Grazia; Monlish, Darlene; Batoon, Lena; Millard, Susan; Spohn, Gabriele; Wiercinska, Eliza; Chendamarai, Ezhil; Yang, Wei; Christ, Stephanie; Gehrs, Leah; Schuettpelz, Laura G.; Dembowsky, Klaus; Pettit, Allison R.; Rettig, Michael P.; Bonig, Halvard
2017-01-01
Interaction between the chemokine receptor CXCR4 and its chief ligand CXCL12 plays a critical role in the retention and migration of hematopoietic stem and progenitor cells (HSPCs) in the bone marrow (BM) microenvironment. In this study, qualitative and quantitative effects of long-term pharmacologic inhibition of the CXCR4/CXCL12 axis on the HSPC compartment were investigated by using 3 structurally unrelated small molecule CXCR4 antagonists. A >10-fold increase in mobilization efficiency was achieved by administering the antagonists as a subcutaneous continuous infusion for 2 weeks compared to a single bolus injection. A concurrent increase in self-renewing proliferation leading to a twofold to fourfold expansion of the HSPC pool in the BM was observed. The expanded BM showed a distinct repopulating advantage when tested in serial competitive transplantation experiments. Furthermore, major changes within the HSPC niche associated with previously described HSPC expansion strategies were not detected in bones treated with a CXCR4 antagonist infusion. Our data suggest that prolonged but reversible pharmacologic blockade of the CXCR4/CXCL12 axis represents an approach that releases HSPC with efficiency superior to any other known mobilization strategy and may also serve as an effective method to expand the BM HSPC pool. PMID:28400375
NASA Technical Reports Server (NTRS)
Wilcox, Brian H. (Inventor); Nasif, Annette K. (Inventor)
2001-01-01
A vehicle, for driving over a ground surface, has a body with a left side, a right side, a front and a back. The vehicle includes left and right drive mechanisms. Each mechanism includes first and second traction elements for engaging the ground surface and transmitting a driving force between the vehicle and ground surface. Each mechanism includes first and second arms coupled to the first and second traction elements for relative rotation about first and second axis respectively. Each mechanism includes a rotor having a third axis, the rotor coupled to the body for rotation about the third axis and coupled to the first and second arms for relative rotation about the third axis. The mechanism includes first and second drive motors for driving the first and second traction elements and first and second transmissions, driven by the first and second motors and engaging the rotor. Driving the first and second traction elements simultaneously rotates the rotor relative to the first and second arms, respectively.
ERIC Educational Resources Information Center
Waller, David; Lippa, Yvonne; Richardson, Adam
2008-01-01
Several lines of research have suggested the importance of egocentric reference systems for determining how the spatial properties of one's environment are mentally organized. Yet relatively little is known about the bases for egocentric reference systems in human spatial memory. In three experiments, we examine the relative importance of…
Connected Vehicle Applications : Mobility
DOT National Transportation Integrated Search
2017-03-03
Connected vehicle mobility applications are commonly referred to as dynamic mobility applications (DMAs). DMAs seek to fully leverage frequently collected and rapidly disseminated multi-source data gathered from connected travelers, vehicles, and inf...
2009-10-07
SECTION A. BUSINESS ENVIRONMENT 1 INTRODUCTION The Strategic Mobility 21 (SM21) program is currently in the process of developing the Joint...Platform ( BPP ) which enables the ability to rapidly compose new business processes and expand the core TMS feature-set to adapt to the challenges...Reference: Strategic Mobility 21 Contract N00014-06-C-0060 Dear Paul, In accordance with the requirements of referenced contract, we are pleased to
Dieleman, Gwendolyn C; Huizink, Anja C; Tulen, Joke H M; Utens, Elisabeth M W J; Creemers, Hanneke E; van der Ende, Jan; Verhulst, Frank C
2015-01-01
It is of debate whether or not childhood anxiety disorders (AD) can be captured by one taxonomic construct. This study examined whether perceived arousal (PA), autonomic nervous system (ANS) and hypothalamic-pituitary-adrenal (HPA) axis measures can distinguish children with different primary diagnoses of clinical anxiety disorders (AD) from each other, and from a general population reference group (GP). The study sample consisted of 152 AD children (comparing separation anxiety disorder, generalized anxiety disorder, social phobia and specific phobia), aged 8- to 12-years, and 200 same-aged reference children. HPA-axis functioning was measured by a diurnal cortisol profile. ANS functioning was measured by continuous measures of skin conductance level in rest and during a mental arithmetic task and high frequency heart rate variability in rest. PA was assessed by a questionnaire. The AD sample showed lower high frequency heart rate variability during rest, heightened anticipatory PA, higher basal and reactive skin conductance levels and lower basal HPA-axis functioning compared to the GP sample. The existence of three or more clinical disorders, i.e. a high clinical 'load', was associated with lower basal HPA-axis functioning, higher skin conductance level and lower posttest PA. Specific phobia could be discerned from social phobia and separation anxiety disorder on higher skin conductance level. Our findings indicated that children with AD have specific psychophysiological characteristics, which resemble the psychophysiological characteristics of chronic stress. A high clinical 'load' is associated with an altered ANS and HPA-axis functioning. Overall, ANS and HPA-axis functioning relate to AD in general, accept for specific phobia. Copyright © 2014 Elsevier Ltd. All rights reserved.
46 CFR 108.101 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Incorporation by reference. 108.101 Section 108.101 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN... Equipment of Mobile Offshore Drilling Units (MODU Code), 19 October 1989 with amendments of June 1991 108...
46 CFR 108.101 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Incorporation by reference. 108.101 Section 108.101 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN... Equipment of Mobile Offshore Drilling Units (MODU Code), 19 October 1989 with amendments of June 1991 108...
46 CFR 108.101 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Incorporation by reference. 108.101 Section 108.101 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN... Equipment of Mobile Offshore Drilling Units (MODU Code), 19 October 1989 with amendments of June 1991 108...
Using Arago's spot to monitor optical axis shift in a Petzval refractor.
Bruns, Donald G
2017-03-10
Measuring the change in the optical alignment of a camera attached to a telescope is necessary to perform astrometric measurements. Camera movement when the telescope is refocused changes the plate constants, invalidating the calibration. Monitoring the shift in the optical axis requires a stable internal reference source. This is easily implemented in a Petzval refractor by adding an illuminated pinhole and a small obscuration that creates a spot of Arago on the camera. Measurements of the optical axis shift for a commercial telescope are given as an example.
James, Susan H; Wald, Rachel; Wintersperger, Bernd J; Jimenez-Juan, Laura; Deva, Djeven; Crean, Andrew M; Nguyen, Elsie; Paul, Narinder S; Ley, Sebastian
2013-08-01
The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes. Copyright © 2013 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Pritchard, Caroline; O'Connor, Gavin; Ashcroft, Alison E
2013-08-06
To achieve comparability of measurement results of protein amount of substance content between clinical laboratories, suitable reference materials are required. The impact on measurement comparability of potential differences in the tertiary and quaternary structure of protein reference standards is as yet not well understood. With the use of human growth hormone as a model protein, the potential of ion mobility spectrometry-mass spectrometry as a tool to assess differences in the structure of protein reference materials and their interactions with antibodies has been investigated here.
NASA Astrophysics Data System (ADS)
Kim, Hyoung Woo; Seok, Ogyun; Moon, Jeong Hyun; Bahng, Wook; Jo, Jungyol
2017-12-01
4H-SiC lateral double implanted metal-oxide-semiconductor field effect transistors (LDIMOSFET) were fabricated on on-axis semi-insulating SiC substrates without using an epi-layer. The LDIMOSFET adopted a current path layer (CPL), which was formed by ion-implantation. The CPL works as a drift region between gate and drain. By using on-axis semi-insulating substrate and optimized CPL parameters, breakdown voltage (BV) of 1093 V and specific on-resistance (R on,sp) of 89.8 mΩ·cm2 were obtained in devices with 20 µm long CPL. Experimentally extracted field-effect channel mobility was 21.7 cm2·V-1·s-1 and the figure-of-merit (BV2/R on,sp) was 13.3 MW/cm2.
Urbinello, Damiano; Röösli, Martin
2013-01-01
When moving around, mobile phones in stand-by mode periodically send data about their positions. The aim of this paper is to evaluate how personal radiofrequency electromagnetic field (RF-EMF) measurements are affected by such location updates. Exposure from a mobile phone handset (uplink) was measured during commuting by using a randomized cross-over study with three different scenarios: disabled mobile phone (reference), an activated dual-band phone and a quad-band phone. In the reference scenario, uplink exposure was highest during train rides (1.19 mW/m(2)) and lowest during car rides in rural areas (0.001 mW/m(2)). In public transports, the impact of one's own mobile phone on personal RF-EMF measurements was not observable because of high background uplink radiation from other people's mobile phone. In a car, uplink exposure with an activated phone was orders of magnitude higher compared with the reference scenario. This study demonstrates that personal RF-EMF exposure is affected by one's own mobile phone in stand-by mode because of its regular location update. Further dosimetric studies should quantify the contribution of location updates to the total RF-EMF exposure in order to clarify whether the duration of mobile phone use, the most common exposure surrogate in the epidemiological RF-EMF research, is actually an adequate exposure proxy.
High aperture off-axis parabolic mirror applied in digital holographic microscopy
NASA Astrophysics Data System (ADS)
Kalenkov, Georgy S.; Kalenkov, Sergey G.; Shtanko, Alexander E.
2018-04-01
An optical scheme of recording digital holograms of micro-objects based on high numerical aperture off-axis parabolic mirror forming a high aperture reference wave is suggested. Registration of digital holograms based on the proposed optical scheme is confirmed experimentally. Application of the proposed approach for hyperspectral holograms registration of micro-objects in incoherent light is discussed.
Parr, W C H; Chatterjee, H J; Soligo, C
2012-04-05
Orientation of the subtalar joint axis dictates inversion and eversion movements of the foot and has been the focus of evolutionary and clinical studies for a number of years. Previous studies have measured the subtalar joint axis against the axis of the whole foot, the talocrural joint axis and, recently, the principal axes of the talus. The present study introduces a new method for estimating average joint axes from 3D reconstructions of bones and applies the method to the talus to calculate the subtalar and talocrural joint axes. The study also assesses the validity of the principal axes as a reference coordinate system against which to measure the subtalar joint axis. In order to define the angle of the subtalar joint axis relative to that of another axis in the talus, we suggest measuring the subtalar joint axis against the talocrural joint axis. We present corresponding 3D vector angles calculated from a modern human skeletal sample. This method is applicable to virtual 3D models acquired through surface-scanning of disarticulated 'dry' osteological samples, as well as to 3D models created from CT or MRI scans. Copyright © 2012 Elsevier Ltd. All rights reserved.
Isotopic and trace element variability in altered and unaltered tuffs at Yucca Mountain, Nevada
Peterman, Z.E.; Spengler, R.W.; Singer, F.R.; Dickerson, R.P.
1993-01-01
Reference stratigraphic sections near Yucca Mountain, Nevada were established and sampled in outcrop areas where the volcanic rocks have been minimally altered. Isotopic and trace element analyses obtained for these reference sections are baseline data for assessing the degree and extent of element mobility attendant with past zonal alteration of the rock mass. In agreement with earlier studies, zeolitization is shown to have occurred under wholesale open-system conditions. Calcium was increased by two three times the baseline values and strontium up to twenty times. In contrast, barium displays less variability, and the high-field strength elements zirconium and titanium were the least mobile during zeolitization. The data reported here establish the usefulness of reference sections of assessing past elements mobility. The information gained will be helpful in predicting possible future element mobility induced by thermally activated fluids in the near field of a potential repository.
Model Predictive Control considering Reachable Range of Wheels for Leg / Wheel Mobile Robots
NASA Astrophysics Data System (ADS)
Suzuki, Naito; Nonaka, Kenichiro; Sekiguchi, Kazuma
2016-09-01
Obstacle avoidance is one of the important tasks for mobile robots. In this paper, we study obstacle avoidance control for mobile robots equipped with four legs comprised of three DoF SCARA leg/wheel mechanism, which enables the robot to change its shape adapting to environments. Our previous method achieves obstacle avoidance by model predictive control (MPC) considering obstacle size and lateral wheel positions. However, this method does not ensure existence of joint angles which achieves reference wheel positions calculated by MPC. In this study, we propose a model predictive control considering reachable mobile ranges of wheels positions by combining multiple linear constraints, where each reachable mobile range is approximated as a convex trapezoid. Thus, we achieve to formulate a MPC as a quadratic problem with linear constraints for nonlinear problem of longitudinal and lateral wheel position control. By optimization of MPC, the reference wheel positions are calculated, while each joint angle is determined by inverse kinematics. Considering reachable mobile ranges explicitly, the optimal joint angles are calculated, which enables wheels to reach the reference wheel positions. We verify its advantages by comparing the proposed method with the previous method through numerical simulations.
Student Transitions Project: Mobility of Transfer Students Sub-Committee Terms of Reference
ERIC Educational Resources Information Center
Ministry of Advanced Education, 2007
2007-01-01
The Student Transitions Project Steering Committee's terms of reference allow it to appoint sub-committees to provide advice. Recently, the committee appointed a Mobility of Transfer Students Sub-Committee (formerly the Enrolment Planning Data Sub-Committee, a sub-committee of the British Columbia Council on Admissions and Transfer). The…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mann, R.C.; Fujimura, K.; Unseren, M.A.
One of the frontiers in intelligent machine research is the understanding of how constructive cooperation among multiple autonomous agents can be effected. The effort at the Center for Engineering Systems Advanced Research (CESAR)at the Oak Ridge National Laboratory (ORNL) focuses on two problem areas: (1) cooperation by multiple mobile robots in dynamic, incompletely known environments; and (2) cooperating robotic manipulators. Particular emphasis is placed on experimental evaluation of research and developments using the CESAR robot system testbeds, including three mobile robots, and a seven-axis, kinematically redundant mobile manipulator. This paper summarizes initial results of research addressing the decoupling of positionmore » and force control for two manipulators holding a common object, and the path planning for multiple robots in a common workspace. 15 refs., 3 figs.« less
Mobile Digest of Education Statistics, 2013. NCES 2014-086
ERIC Educational Resources Information Center
Snyder, Thomas D.
2014-01-01
This is the first edition of the "Mobile Digest of Education Statistics." This compact compilation of statistical information covers prekindergarten through graduate school to describe the current American education scene. The "Mobile Digest" is designed as an easy mobile reference for materials found in detail in the…
The size and mobility of streambed particles are sensitive to changes in the balance between sediment supply and transport. Therefore, changes in mobility can be an indicator of natural or anthropogenic alterations in this balance. Predictions of the critical diameter for mobil...
Off-axis full-field swept-source optical coherence tomography using holographic refocusing
NASA Astrophysics Data System (ADS)
Hillmann, Dierck; Franke, Gesa; Hinkel, Laura; Bonin, Tim; Koch, Peter; Hüttmann, Gereon
2013-03-01
We demonstrate a full-field swept-source OCT using an off-axis geometry of the reference illumination. By using holographic refocusing techniques, a uniform lateral resolution is achieved over the measurement depth of approximately 80 Rayleigh lengths. Compared to a standard on-axis setup, artifacts and autocorrelation signals are suppressed and the measurement depth is doubled by resolving the complex conjugate ambiguity. Holographic refocusing was done efficiently by Fourier-domain resampling as demonstrated before in inverse scattering and holoscopy. It allowed to reconstruct a complete volume with about 10μm resolution over the complete measurement depth of more than 10mm. Off-axis full-field swept-source OCT enables high measurement depths, spanning many Rayleigh lengths with reduced artifacts.
A Simple Interface for 3D Position Estimation of a Mobile Robot with Single Camera
Chao, Chun-Tang; Chung, Ming-Hsuan; Chiou, Juing-Shian; Wang, Chi-Jo
2016-01-01
In recent years, there has been an increase in the number of mobile robots controlled by a smart phone or tablet. This paper proposes a visual control interface for a mobile robot with a single camera to easily control the robot actions and estimate the 3D position of a target. In this proposal, the mobile robot employed an Arduino Yun as the core processor and was remote-controlled by a tablet with an Android operating system. In addition, the robot was fitted with a three-axis robotic arm for grasping. Both the real-time control signal and video transmission are transmitted via Wi-Fi. We show that with a properly calibrated camera and the proposed prototype procedures, the users can click on a desired position or object on the touchscreen and estimate its 3D coordinates in the real world by simple analytic geometry instead of a complicated algorithm. The results of the measurement verification demonstrates that this approach has great potential for mobile robots. PMID:27023556
Combined corona discharge and UV photoionization source for ion mobility spectrometry.
Bahrami, Hamed; Tabrizchi, Mahmoud
2012-08-15
An ion mobility spectrometer is described which is equipped with two non-radioactive ion sources, namely an atmospheric pressure photoionization and a corona discharge ionization source. The two sources cannot only run individually but are additionally capable of operating simultaneously. For photoionization, a UV lamp was mounted parallel to the axis of the ion mobility cell. The corona discharge electrode was mounted perpendicular to the UV radiation. The total ion current from the photoionization source was verified as a function of lamp current, sample flow rate, and drift field. Simultaneous operation of the two ionization sources was investigated by recording ion mobility spectra of selected samples. The design allows one to observe peaks from either the corona discharge or photoionization individually or simultaneously. This makes it possible to accurately compare peaks in the ion mobility spectra from each individual source. Finally, the instrument's capability for discriminating two peaks appearing in approximately identical drift times using each individual ionization source is demonstrated. Copyright © 2012 Elsevier B.V. All rights reserved.
Speed control for a mobile robot
NASA Astrophysics Data System (ADS)
Kolli, Kaylan C.; Mallikarjun, Sreeram; Kola, Krishnamohan; Hall, Ernest L.
1997-09-01
Automated guided vehicles (AGVs) have many potential applications in manufacturing, medicine, space and defense. The purpose of this paper is to describe exploratory research on the design of a speed control for a modular autonomous mobile robot controller. The speed control of the traction motor is essential for safe operation of a mobile robot. The challenges of autonomous operation of a vehicle require safe, runaway and collision free operation. A mobile robot test-bed has been constructed using a golf cart base. The computer controlled speed control has been implemented and works with guidance provided by vision system and obstacle avoidance using ultrasonic sensors systems. A 486 computer through a 3- axis motion controller supervises the speed control. The traction motor is controlled via the computer by an EV-1 speed control. Testing of the system was done both in the lab and on an outside course with positive results. This design is a prototype and suggestions for improvements are also given. The autonomous speed controller is applicable for any computer controlled electric drive mobile vehicle.
A Simple Interface for 3D Position Estimation of a Mobile Robot with Single Camera.
Chao, Chun-Tang; Chung, Ming-Hsuan; Chiou, Juing-Shian; Wang, Chi-Jo
2016-03-25
In recent years, there has been an increase in the number of mobile robots controlled by a smart phone or tablet. This paper proposes a visual control interface for a mobile robot with a single camera to easily control the robot actions and estimate the 3D position of a target. In this proposal, the mobile robot employed an Arduino Yun as the core processor and was remote-controlled by a tablet with an Android operating system. In addition, the robot was fitted with a three-axis robotic arm for grasping. Both the real-time control signal and video transmission are transmitted via Wi-Fi. We show that with a properly calibrated camera and the proposed prototype procedures, the users can click on a desired position or object on the touchscreen and estimate its 3D coordinates in the real world by simple analytic geometry instead of a complicated algorithm. The results of the measurement verification demonstrates that this approach has great potential for mobile robots.
NASA Technical Reports Server (NTRS)
1982-01-01
A design concept that will implement a mapping capability for the Orbital Camera Payload System (OCPS) when ground control points are not available is discussed. Through the use of stellar imagery collected by a pair of cameras whose optical axis are structurally related to the large format camera optical axis, such pointing information is made available.
Comparison of Fixed-Stabilizer, Adjustable-Stabilizer and All-Moveable Horizontal Tails
1945-10-01
the thrust axis and wind direction at Infinity, degrees; primed to indicate that a is corrected for ground interference effects 5 angular ...deflection of control surface, degrees i+- maximum angular deflection of stabilizer measured with reference to thrust axis, degrees hnax...5e maximum negative angular deflection of elevator, degrees E downwash angle at teil, degrees; primed to indicate that e Is
Control System for Bearingless Motor-generator
NASA Technical Reports Server (NTRS)
Kascak, Peter E. (Inventor); Jansen, Ralph H. (Inventor); Dever, Timothy P. (Inventor)
2008-01-01
A control system for an electromagnetic rotary drive for bearingless motor-generators comprises a winding configuration comprising a plurality of individual pole pairs through which phase current flows, each phase current producing both a lateral force and a torque. A motor-generator comprises a stator, a rotor supported for movement relative to the stator, and a control system. The motor-generator comprises a winding configuration supported by the stator. The winding configuration comprises at least three pole pairs through which phase current flows resulting in three three-phase systems. Each phase system has a first rotor reference frame axis current that produces a levitating force with no average torque and a second rotor reference frame axis current that produces torque.
Generation of mechanical oscillation applicable to vibratory rate gyroscopes
NASA Technical Reports Server (NTRS)
Lemkin, Mark A. (Inventor); Juneau, Thor N. (Inventor); Clark, William A. (Inventor); Roessig, Allen W. (Inventor)
2001-01-01
To achieve a drive-axis oscillation with improved frequency and amplitude stability, additional feedback loops are used to adjust force-feedback loop parameters. An amplitude-control loop measures oscillation amplitude, compares this value to the desired level, and adjusts damping of the mechanical sense-element to grow or shrink oscillation amplitude as appropriate. A frequency-tuning loop measures the oscillation frequency, compares this value with a highly stable reference, and adjusts the gain in the force-feedback loop to keep the drive-axis oscillation frequency at the reference value. The combined topology simultaneously controls both amplitude and frequency. Advantages of the combined topology include improved stability, fast oscillation start-up, low power consumption, and excellent shock rejection.
Inflight alignment of payload inertial reference from Shuttle navigation system
NASA Astrophysics Data System (ADS)
Treder, A. J.; Norris, R. E.; Ruprecht, R.
Two methods for payload attitude initialization from the STS Orbiter have been proposed: body axis maneuvers (BAM) and star line maneuvers (SLM). The first achieves alignment directly through the Shuttle star tracker, while the second, indirectly through the stellar-updated Shuttle inertial platform. The Inertial Upper Stage (IUS) with its strapdown navigation system is used to demonstrate in-flight alignment techniques. Significant accuracy can be obtained with minimal impact on Orbiter operations, with payload inertial reference potentially approaching the accuracy of the Shuttle star tracker. STS-6 flight performance parameters, including alignment stability, are discussed and compared with operational complexity. Results indicate overall alignment stability of .06 deg, 3 sigma per axis.
Control system for bearingless motor-generator
NASA Technical Reports Server (NTRS)
Jansen, Ralph H. (Inventor); Dever, Timothy P. (Inventor); Kascak, Peter E. (Inventor)
2010-01-01
A control system for an electromagnetic rotary drive for bearingless motor-generators comprises a winding configuration comprising a plurality of individual pole pairs through which phase current flows, each phase current producing both a lateral force and a torque. A motor-generator comprises a stator, a rotor supported for movement relative to the stator, and a control system. The motor-generator comprises a winding configuration supported by the stator. The winding configuration comprises at least three pole pairs through which phase current flows resulting in three three-phase systems. Each phase system has a first rotor reference frame axis current that produces a levitating force with no average torque and a second rotor reference frame axis current that produces torque.
Effect of crystal orientation on conductivity and electron mobility in single-crystal alumina
NASA Technical Reports Server (NTRS)
Will, Fritz G.; Delorenzi, Horst G.; Janora, Kevin H.
1992-01-01
The electrical conductivity of high-purity, single-crystal alumina is determined parallel to and perpendicular to the c-axis. The mean conductivity of four samples of each orientation is a factor 3.3 higher parallel to the c-axis than perpendicular to it. The conductivity as a function of temperature is attributed to extrinsic electron conduction at temperatures from 400 to 900 C, and intrinsic semiconduction at temperatures from 900 to 1300 C. In the high-temperature regime, the slope on all eight specimens is 4.7 +/- 0.1 eV. Hence, the thermal bandgap at O K is 9.4 +/- 0.2 eV.
Quantifying functional mobility progress for chronic disease management.
Boyle, Justin; Karunanithi, Mohan; Wark, Tim; Chan, Wilbur; Colavitti, Christine
2006-01-01
A method for quantifying improvements in functional mobility is presented based on patient-worn accelerometer devices. For patients with cardiovascular, respiratory, or other chronic disease, increasing the amount of functional mobility is a large component of rehabilitation programs. We have conducted an observational trial on the use of accelerometers for quantifying mobility improvements in a small group of chronic disease patients (n=15, 48 - 86 yrs). Cognitive impairments precluded complex instrumentation of patients, and movement data was obtained from a single 2-axis accelerometer device worn at the hip. In our trial, movement data collected from accelerometer devices was classified into Lying vs Sitting/Standing vs Walking/Activity movements. This classification enabled the amount of walking to be quantified and graphically presented to clinicians and carers for feedback on exercise efficacy. Presenting long term trends in this data to patients also provides valuable feedback for self managed care and assisting with compliance.
Mobile Technologies and Roving Reference
ERIC Educational Resources Information Center
Penner, Katherine
2011-01-01
As 21st century librarians, we have made apt adjustments for reaching out into the digital world, but we need to consider the students who still use library services within our walls. We can use available handheld, mobile technologies to help patrons too shy to approach the desk and free library staff to bring reference service directly to patrons.
Laser-Camera Vision Sensing for Spacecraft Mobile Robot Navigation
NASA Technical Reports Server (NTRS)
Maluf, David A.; Khalil, Ahmad S.; Dorais, Gregory A.; Gawdiak, Yuri
2002-01-01
The advent of spacecraft mobile robots-free-flyng sensor platforms and communications devices intended to accompany astronauts or remotely operate on space missions both inside and outside of a spacecraft-has demanded the development of a simple and effective navigation schema. One such system under exploration involves the use of a laser-camera arrangement to predict relative positioning of the mobile robot. By projecting laser beams from the robot, a 3D reference frame can be introduced. Thus, as the robot shifts in position, the position reference frame produced by the laser images is correspondingly altered. Using normalization and camera registration techniques presented in this paper, the relative translation and rotation of the robot in 3D are determined from these reference frame transformations.
Prieur, J-M; Bourdin, C; Sarès, F; Vercher, J-L
2006-01-01
A major issue in motor control studies is to determine whether and how we use spatial frames of reference to organize our spatially oriented behaviors. In previous experiments we showed that simulated body tilt during off-axis rotation affected the performance in verbal localization and manual pointing tasks. It was hypothesized that the observed alterations were at least partly due to a change in the orientation of the egocentric frame of reference, which was indeed centered on the body but aligned with the gravitational vector. The present experiments were designed to test this hypothesis in a situation where no inertial constraints (except the usual gravitational one) exist and where the orientation of the body longitudinal z-axis was not aligned with the direction of the gravity. Eleven subjects were exposed to real static body tilt and were required to verbally localize (experiment 1) and to point as accurately as possible towards (experiment 2) memorized visual targets, in two conditions, Head-Free and Head-Fixed conditions. Results show that the performance was only affected by real body tilt in the localization task performed when the subject's head was tilted relative to the body. Thus, dissociation between gravity and body longitudinal z-axis alone is not responsible for localization nor for pointing errors. Therefore, the egocentric frame of reference seems independent from the orientation of the gravity with regard to body z-axis as expected from our previous studies. Moreover, the use of spatial referentials appears to be less mandatory than expected for pointing movements (motor task) than for localization task (cognitive task).
A Study on Mobile Learning as a Learning Style in Modern Research Practice
ERIC Educational Resources Information Center
Joan, D. R. Robert
2013-01-01
Mobile learning is a kind of learning that takes place via a portable handheld electronic device. It also refers to learning via other kinds of mobile devices such as tablet computers, net-books and digital readers. The objective of mobile learning is to provide the learner the ability to assimilate learning anywhere and at anytime. Mobile devices…
Interactions between CXCR4 and CXCL12 promote cell migration and invasion of canine hemangiosarcoma.
Im, K S; Graef, A J; Breen, M; Lindblad-Toh, K; Modiano, J F; Kim, J-H
2017-06-01
The CXCR4/CXCL12 axis plays an important role in cell locomotion and metastasis in many cancers. In this study, we hypothesized that the CXCR4/CXCL12 axis promotes migration and invasion of canine hemangiosarcoma (HSA) cells. Transcriptomic analysis across 12 HSA cell lines and 58 HSA whole tumour tissues identified heterogeneous expression of CXCR4 and CXCL12, which was associated with cell movement. In vitro, CXCL12 promoted calcium mobilization, cell migration and invasion that were directly proportional to surface expression of CXCR4; furthermore, these responses proved sensitive to the CXCR4 antagonist, AMD3100, in HSA cell lines. These results indicate that CXCL12 potentiates migration and invasion of canine HSA cells through CXCR4 signalling. The direct relationship between these responses in HSA cells suggests that the CXCR4/CXCL12 axis contributes to HSA progression. © 2015 John Wiley & Sons Ltd.
theoretically. Negative ions are produced by a corona discharge from a needle placed along the axis of a nozzle. A dense air-vapor mixture is...interaction with the gas molecules to an electrode of high potential. The effectiveness of the viscous coupling depends on the charge mobility being
Friction Stir Weld System for Welding and Weld Repair
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor); Romine, Peter L. (Inventor); Oelgoetz, Peter A. (Inventor)
2001-01-01
A friction stir weld system for welding and weld repair has a base foundation unit connected to a hydraulically controlled elevation platform and a hydraulically adjustable pin tool. The base foundation unit may be fixably connected to a horizontal surface or may be connected to a mobile support in order to provide mobility to the friction stir welding system. The elevation platform may be utilized to raise and lower the adjustable pin tool about a particular axis. Additional components which may be necessary for the friction stir welding process include back plate tooling, fixturing and/or a roller mechanism.
Research Diagnostic Criteria for Temporomandibular Disorders: Validity of Axis I Diagnoses
Truelove, Edmond; Pan, Wei; Look, John O.; Mancl, Lloyd A.; Ohrbach, Richard K.; Velly, Ana; Huggins, Kimberly; Lenton, Patricia; Schiffman, Eric L.
2011-01-01
AIMS To estimate the criterion validity of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I TMD diagnoses. METHODS A combined total of 614 TMD community and clinic cases and 91 controls were examined at 3 study sites. RDC/TMD Axis I diagnoses were algorithmically derived from an examination performed by calibrated dental hygienists. Reference standards (Gold Standards) were established by means of consensus diagnoses rendered by 2 TMD experts using all available clinical data, including imaging studies. Validity of the RDC/TMD Axis I TMD diagnoses was estimated relative to reference-standard diagnoses (gold standard diagnoses). Target sensitivity and specificity were set a priori at ≥ 0.70 and ≥ 0.95, respectively. RESULTS Target sensitivity and specificity were not observed for any of the 8 RDC/TMD diagnoses. The highest validity was achieved for Group Ia myofascial pain (sensitivity 0.65, specificity 0.92) and Group Ib myofascial pain with limited opening (sensitivity 0.79, specificity 0.92). Target sensitivity and specificity were observed only when both Group I diagnoses were combined (0.87 and 0.98, respectively). For Group II (disc displacements) and Group III (arthralgia, arthritis, arthrosis) diagnoses, all estimates for sensitivity were below target (0.03 to 0.53), and specificity ranged from below to on target (0.86 to 0.99). CONCLUSION The RDC/TMD Axis I TMD diagnoses did not reach the targets set at sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Target validity was obtained only for myofascial pain without differentiation between normal and limited opening. Revision of the current Axis I TMD diagnostic algorithms is warranted to improve their validity. PMID:20213030
NASA Astrophysics Data System (ADS)
Carlson, C. W.; Pluhar, C. J.; Glen, J. M.; Farner, M. J.
2012-12-01
Accommodating ~20-25% of the dextral-motion between the Pacific and North American plates the Walker Lane is represented as an elongate, NW oriented, region of active tectonics positioned between the northwesterly-translating Sierra Nevada microplate and the east-west extension of the Basin and Range. This region of transtension is being variably accommodated on regional-scale systems of predominantly strike-slip faulting. At the western edge of the central Walker Lane (ca. 38°-39°N latitude) is a region of crustal-scale blocks bounded by wedge-shaped depositional-basins and normal-fault systems, here defined as the west-central Walker Lane (WCWL). Devoid of obvious strike-slip faulting, the presence of tectonic-block vertical-axis rotations in the WCWL represents unrecognized components of dextral-shearing and/or changes of strain-accommodation over time. We use paleomagnetic reference directions for Eureka Valley Tuff (EVT) members of the late Miocene Stanislaus Group as spatial and temporal markers for documentation of tectonic-block vertical-axis rotations near Bridgeport, CA. Study-site rotations revealed discrete rotational domains of mean vertical-axis rotation ranging from ~10°-30° with heterogeneous regional distribution. Additionally, the highest measured magnitudes of vertical-axis rotation (~50°-60° CW) define a 'Region of High Strain' that includes the wedge-shaped Bridgeport Valley (Basin). This study revealed previously-unrecognized tectonic rotation of reference direction sites from prior studies for two (By-Day and Upper) of the three members of the EVT, resulting in under-estimates of regional strain accommodation by these studies. Mean remanent directions and virtual geomagnetic poles utilized in our study yielded a recalculated reference direction for the By-Day member of: Dec.=353.2°; Inc.= 43.7°; α95=10.1, in agreement with new measurements in the stable Sierra Nevada. This recalculated direction confirmed the presence of previously unrecognized reference site rotations, and provided an additional reference direction for determining vertical-axis rotation magnitudes. We present a kinematic model based on mean rotation magnitudes of ~30° CW for the Sweetwater Mountains and Bodie Hills that accounts for rotational-strain accommodation of dextral shear in the WCWL since the late Miocene. This model considers rotational magnitudes, paleostrain indicators, edge-effects, and strain-accommodating structures of rotating crustal blocks to represent changes in regional strain accommodation over time. The results and models presented here elucidate the complicated and evolving nature of the WCWL, and further understanding of variations in strain accommodation for the Walker Lane.
ERIC Educational Resources Information Center
Ozdemir, Oguzhan; Erdemci, Husamettin
2017-01-01
The term mobile portfolio refers to creating, evaluating and sharing portfolios in mobile environments. Many of the states that pose an obstacle for portfolio usage are now extinguished through mobile portfolios. The aim in this research is to determine the effect of mobile portfolio supported mastery learning model on students' success and…
System Identification and Automatic Mass Balancing of Ground-Based Three-Axis Spacecraft Simulator
2006-08-01
commanded torque to move away from these singularity points. The introduction of this error may not degrade the performance for large slew angle ...trajectory has been generated and quaternion feedback control has been implemented for reference trajectory tracking. The testbed was reasonably well...System Identification and Automatic Mass Balancing of Ground-Based Three-Axis Spacecraft Simulator Jae-Jun Kim∗ and Brij N. Agrawal † Department of
Radius of Curvature of Off-Axis Paraboloids
NASA Technical Reports Server (NTRS)
Robinson, Brian; Reardon, Patrick; Hadaway, James; Geary, Joseph; Russell, Kevin (Technical Monitor)
2002-01-01
We present several methods for measuring the vertex radius of curvature of off-axis paraboloidal mirrors. One is based on least-squares fitting of interferometer output, one on comparison of sagittal and tangential radii of curvature, and another on measurement of displacement of the nulled test article from the ideal reference wave. Each method defines radius of curvature differently and, as a consequence, produces its own sort of errors.
Control of an automated mobile manipulator using artificial immune system
NASA Astrophysics Data System (ADS)
Deepak, B. B. V. L.; Parhi, Dayal R.
2016-03-01
This paper addresses the coordination and control of a wheeled mobile manipulator (WMM) using artificial immune system. The aim of the developed methodology is to navigate the system autonomously and transport jobs and tools in manufacturing environments. This study integrates the kinematic structures of a four-axis manipulator and a differential wheeled mobile platform. The motion of the developed WMM is controlled by the complete system of parametric equation in terms of joint velocities and makes the robot to follow desired trajectories by the manipulator and platform within its workspace. The developed robot system performs its action intelligently according to the sensed environmental criteria within its search space. To verify the effectiveness of the proposed immune-based motion planner for WMM, simulations as well as experimental results are presented in various unknown environments.
NASA Technical Reports Server (NTRS)
Mann, R. C.; Fujimura, K.; Unseren, M. A.
1992-01-01
One of the frontiers in intelligent machine research is the understanding of how constructive cooperation among multiple autonomous agents can be effected. The effort at the Center for Engineering Systems Advanced Research (CESAR) at the Oak Ridge National Laboratory (ORNL) focuses on two problem areas: (1) cooperation by multiple mobile robots in dynamic, incompletely known environments; and (2) cooperating robotic manipulators. Particular emphasis is placed on experimental evaluation of research and developments using the CESAR robot system testbeds, including three mobile robots, and a seven-axis, kinematically redundant mobile manipulator. This paper summarizes initial results of research addressing the decoupling of position and force control for two manipulators holding a common object, and the path planning for multiple robots in a common workspace.
NASA Astrophysics Data System (ADS)
Green, K. N.; van Alstine, R. L.
This paper presents the current performance levels of the SDG-5 gyro, a high performance two-axis dynamically tuned gyro, and the DRIRU II redundant inertial reference unit relating to stabilization and pointing applications. Also presented is a discussion of a product improvement program aimed at further noise reductions to meet the demanding requirements of future space defense applications.
Predictive momentum management for a space station measurement and computation requirements
NASA Technical Reports Server (NTRS)
Adams, John Carl
1986-01-01
An analysis is made of the effects of errors and uncertainties in the predicting of disturbance torques on the peak momentum buildup on a space station. Models of the disturbance torques acting on a space station in low Earth orbit are presented, to estimate how accurately they can be predicted. An analysis of the torque and momentum buildup about the pitch axis of the Dual Keel space station configuration is formulated, and a derivation of the Average Torque Equilibrium Attitude (ATEA) is presented, for the case of no MRMS (Mobile Remote Manipulation System) motion, Y vehicle axis MRMS motion, and Z vehicle axis MRMS motion. Results showed the peak momentum buildup to be approximately 20000 N-m-s and to be relatively insensitive to errors in the predicting torque models, for Z axis motion of the MRMS was found to vary significantly with model errors, but not exceed a value of approximately 15000 N-m-s for the Y axis MRMS motion with 1 deg attitude hold error. Minimum peak disturbance momentum was found not to occur at the ATEA angle, but at a slightly smaller angle. However, this minimum peak momentum attitude was found to produce significant disturbance momentum at the end of the predicting time interval.
Information Use and Barriers on a Mobile App in Distance Learning
ERIC Educational Resources Information Center
Du, Yunfei
2015-01-01
Mobile technologies such as iPhone apps make it possible for learners to freely access course content management systems, library Web sites, as well as reference services from anywhere, anytime. This paper reviewed the current status of mobile learning and suggested possible factors influencing the use of mobile apps in online learning. The author…
Schutte, Anne R.; Spencer, John P.
2009-01-01
This study tested a dynamic field theory (DFT) of spatial working memory and an associated spatial precision hypothesis (SPH). Between three and six years of age there is a qualitative shift in how children use reference axes to remember locations: 3-year-olds’ spatial recall responses are biased toward reference axes after short memory delays, whereas 6-year-olds’ responses are biased away from reference axes. According to the DFT and the SPH, quantitative improvements over development in the precision of excitatory and inhibitory working memory processes lead to this qualitative shift. Simulations of the DFT in Experiment 1 predict that improvements in precision should cause the spatial range of targets attracted toward a reference axis to narrow gradually over development with repulsion emerging and gradually increasing until responses to most targets show biases away from the axis. Results from Experiment 2 with 3- to 5-year-olds support these predictions. Simulations of the DFT in Experiment 3 quantitatively fit the empirical results and offer insights into the neural processes underlying this developmental change. PMID:19968430
Comfort Contours: Inter-Axis Equivalence
NASA Astrophysics Data System (ADS)
Griefahn, B.; Bröde, P.
1997-07-01
Inter-axis equivalence for sinusoidal vibrations as stipulated by ISO/DIS 2631 for seated persons was studied by adjusting the acceleration of a horizontal sinusoidal test vibration (x∨y) until it caused equal sensation as a vertical sinusoidal reference motion of the same frequency. The reference vibrations consisted of sine waves ranging from 1·6 to 12·5Hz and were presented with three weighted accelerations ofazw=0·3, 0·6 and 1·2ms-2r.m.s. (reference contours). 26 subjects (15 men, 11 women, 20-55yrs, 153-187cm) participated in the respective experiments. Based on the three reference contours, predicted values for horizontal motions were calculated by using the weighting factors provided in ISO/DIS 2631. The International standard was confirmed insofar as the shape of the contours determined for horizontal motions was independent from vibration magnitudes as sensitivity to fore-and-aft and to lateral motions was similar. However, the accelerations adjusted for horizontal vibrations were considerably lower than predicted, suggesting that the weighing factors provided in ISO/DIS 2631 need to be corrected.
Experiences with the DSM-III in a psychiatric consultation/liaison service.
Larsen, F
1986-01-01
375 patients referred to consultation/liaison service at a general hospital from the neurological and internal medical department were diagnosed according to the DSM-III criteria for axis I and II. The sample represents all the patients referred from the two departments in a two year period. The phenomenological approach of the DSM-III and its reliability, is an advantage over older classification systems in the psychiatric consultation/liaison work. The system was easily applicable in this setting, leaving only 4 percent with "Diagnoses deferred" on both axes. From the consultation/liaison psychiatrist's point of view, special problems seemed to exist concerning the categories "Somatoform disorders" and "Psychological factors affecting physical condition", and the concepts of the axis II.
NASA Technical Reports Server (NTRS)
Bennett, R. L.
1975-01-01
The analytical techniques and computer program developed in the fully-coupled rotor vibration study are described. The rotor blade natural frequency and mode shape analysis was implemented in a digital computer program designated DF1758. The program computes collective, cyclic, and scissor modes for a single blade within a specified range of frequency for specified values of rotor RPM and collective angle. The analysis includes effects of blade twist, cg offset from reference axis, and shear center offset from reference axis. Coupled inplane, out-of-plane, and torsional vibrations are considered. Normalized displacements, shear forces and moments may be printed out and Calcomp plots of natural frequencies as a function of rotor RPM may be produced.
OPTICAL TRANSCRIBING OSCILLOSCOPE
Kerns, Q.A.
1961-09-26
A device is designed for producing accurate graphed waveforms of very fast electronic pulses. The fast pulse is slowly tracked on a cathode ray tube and a pair of photomultiplier tubes, exposed to the pulse trace, view separate vertical portions thereof at each side of a fixed horizontal reference. Each phototube produces an output signal indicative of vertical movement of the exposed trace, which simultaneous signals are compared in a difference amplifier. The amplifier produces a difference signal which, when applied to the cathode ray tube, maintains the trace on the reference. A graphic recorder receives the amplified difference signal at an x-axis input, while a y-axis input is synchronized with the tracking time of the cathode ray tube and therefore graphs the enlarged waveshape.
Chemokine GPCR Signaling Inhibits β-Catenin during Zebrafish Axis Formation
Wu, Shu-Yu; Shin, Jimann; Sepich, Diane S.; Solnica-Krezel, Lilianna
2012-01-01
Embryonic axis formation in vertebrates is initiated by the establishment of the dorsal Nieuwkoop blastula organizer, marked by the nuclear accumulation of maternal β-catenin, a transcriptional effector of canonical Wnt signaling. Known regulators of axis specification include the canonical Wnt pathway components that positively or negatively affect β-catenin. An involvement of G-protein coupled receptors (GPCRs) was hypothesized from experiments implicating G proteins and intracellular calcium in axis formation, but such GPCRs have not been identified. Mobilization of intracellular Ca2+ stores generates Ca2+ transients in the superficial blastomeres of zebrafish blastulae when the nuclear accumulation of maternal β-catenin marks the formation of the Nieuwkoop organizer. Moreover, intracellular Ca2+ downstream of non-canonical Wnt ligands was proposed to inhibit β-catenin and axis formation, but mechanisms remain unclear. Here we report a novel function of Ccr7 GPCR and its chemokine ligand Ccl19.1, previously implicated in chemotaxis and other responses of dendritic cells in mammals, as negative regulators of β-catenin and axis formation in zebrafish. We show that interference with the maternally and ubiquitously expressed zebrafish Ccr7 or Ccl19.1 expands the blastula organizer and the dorsoanterior tissues at the expense of the ventroposterior ones. Conversely, Ccr7 or Ccl19.1 overexpression limits axis formation. Epistatic analyses demonstrate that Ccr7 acts downstream of Ccl19.1 ligand and upstream of β-catenin transcriptional targets. Moreover, Ccl19/Ccr7 signaling reduces the level and nuclear accumulation of maternal β-catenin and its axis-inducing activity and can also inhibit the Gsk3β -insensitive form of β-catenin. Mutational and pharmacologic experiments reveal that Ccr7 functions during axis formation as a GPCR to inhibit β-catenin, likely by promoting Ca2+ transients throughout the blastula. Our study delineates a novel negative, Gsk3β-independent control mechanism of β-catenin and implicates Ccr7 as a long-hypothesized GPCR regulating vertebrate axis formation. PMID:23055828
The diagnosed mobile limiters of the TJ-II stellarator for plasma boundary studies
NASA Astrophysics Data System (ADS)
de la Cal, E.; Tabarés, F. L.; Tafalla, D.; Cortés, I. García.; Hidalgo, C.; López-Fraguas, A.
TJ-II is a medium size (major radius R=1.5 m, average plasma radius a <0.25 m, on axis magnetic field B=1 T) helical axis stellarator. The main characteristic is its magnetic configuration flexibility, due to the separate control of the different magnetic field coils. The two diagnosed mobile limiters are installed to reduce thermal loads on the thin protection plates of the contacting plasma-chamber regions and to study the plasma edge. First diagnostics are a set of thermocouples, Langmuir probes, H α-detectors and a CCD video camera with different filters (atomic lines of HeI, H α and near IR) looking at the limiter. A method of passive spectroscopy is proposed to map the electron temperature and density over the whole limiter surface by analysing the emission of helium recycling neutrals. It is expected from previous results of other stellarators, that the boundary magnetic topology will have a strong influence on the plasma-wall interaction. The mobile limiters can control the last closed magnetic surface and diagnose the plasma boundary. A qualitative different plasma edge scenario is foreseen between the limiter and the natural island divertor configuration (rational rotational transform inside the limiter radius). Plasma-wall interaction in TJ-II shows very specific features and the optimisation of the plasma edge topology can influence strongly the core plasma parameters. In particular, impurity screening will be a challenge due to the large power density which will be available in future (up to 2 MW NBI for 0.5 s). A safe operation for future high β-plasmas is also required and the mobile limiters should help to remove a fraction of the conductive/convective power.
Alatise, Mary B; Hancke, Gerhard P
2017-09-21
Using a single sensor to determine the pose estimation of a device cannot give accurate results. This paper presents a fusion of an inertial sensor of six degrees of freedom (6-DoF) which comprises the 3-axis of an accelerometer and the 3-axis of a gyroscope, and a vision to determine a low-cost and accurate position for an autonomous mobile robot. For vision, a monocular vision-based object detection algorithm speeded-up robust feature (SURF) and random sample consensus (RANSAC) algorithms were integrated and used to recognize a sample object in several images taken. As against the conventional method that depend on point-tracking, RANSAC uses an iterative method to estimate the parameters of a mathematical model from a set of captured data which contains outliers. With SURF and RANSAC, improved accuracy is certain; this is because of their ability to find interest points (features) under different viewing conditions using a Hessain matrix. This approach is proposed because of its simple implementation, low cost, and improved accuracy. With an extended Kalman filter (EKF), data from inertial sensors and a camera were fused to estimate the position and orientation of the mobile robot. All these sensors were mounted on the mobile robot to obtain an accurate localization. An indoor experiment was carried out to validate and evaluate the performance. Experimental results show that the proposed method is fast in computation, reliable and robust, and can be considered for practical applications. The performance of the experiments was verified by the ground truth data and root mean square errors (RMSEs).
Hancke, Gerhard P.
2017-01-01
Using a single sensor to determine the pose estimation of a device cannot give accurate results. This paper presents a fusion of an inertial sensor of six degrees of freedom (6-DoF) which comprises the 3-axis of an accelerometer and the 3-axis of a gyroscope, and a vision to determine a low-cost and accurate position for an autonomous mobile robot. For vision, a monocular vision-based object detection algorithm speeded-up robust feature (SURF) and random sample consensus (RANSAC) algorithms were integrated and used to recognize a sample object in several images taken. As against the conventional method that depend on point-tracking, RANSAC uses an iterative method to estimate the parameters of a mathematical model from a set of captured data which contains outliers. With SURF and RANSAC, improved accuracy is certain; this is because of their ability to find interest points (features) under different viewing conditions using a Hessain matrix. This approach is proposed because of its simple implementation, low cost, and improved accuracy. With an extended Kalman filter (EKF), data from inertial sensors and a camera were fused to estimate the position and orientation of the mobile robot. All these sensors were mounted on the mobile robot to obtain an accurate localization. An indoor experiment was carried out to validate and evaluate the performance. Experimental results show that the proposed method is fast in computation, reliable and robust, and can be considered for practical applications. The performance of the experiments was verified by the ground truth data and root mean square errors (RMSEs). PMID:28934102
Ryan, Karen K; Packard, Amy E B; Larson, Karlton R; Stout, Jayna; Fourman, Sarah M; Thompson, Abigail M K; Ludwick, Kristen; Habegger, Kirk M; Stemmer, Kerstin; Itoh, Nobuyuki; Perez-Tilve, Diego; Tschöp, Matthias H; Seeley, Randy J; Ulrich-Lai, Yvonne M
2018-01-01
In response to an acute threat to homeostasis or well-being, the hypothalamic-pituitary-adrenocortical (HPA) axis is engaged. A major outcome of this HPA axis activation is the mobilization of stored energy, to fuel an appropriate behavioral and/or physiological response to the perceived threat. Importantly, the extent of HPA axis activity is thought to be modulated by an individual's nutritional environment. In this study, we report that nutritional manipulations signaling a relative depletion of dietary carbohydrates, thereby inducing nutritional ketosis, acutely and chronically activate the HPA axis. Male rats and mice maintained on a low-carbohydrate high-fat ketogenic diet (KD) exhibited canonical markers of chronic stress, including increased basal and stress-evoked plasma corticosterone, increased adrenal sensitivity to adrenocorticotropin hormone, increased stress-evoked c-Fos immunolabeling in the paraventricular nucleus of the hypothalamus, and thymic atrophy, an indicator of chronic glucocorticoid exposure. Moreover, acutely feeding medium-chain triglycerides (MCTs) to rapidly induce ketosis among chow-fed male rats and mice also acutely increased HPA axis activity. Lastly, and consistent with a growing literature that characterizes the hepatokine fibroblast growth factor-21 (FGF21) as both a marker of the ketotic state and as a key metabolic stress hormone, the HPA response to both KD and MCTs was significantly blunted among mice lacking FGF21. We conclude that dietary manipulations that induce ketosis lead to increased HPA axis tone, and that the hepatokine FGF21 may play an important role to facilitate this effect. Copyright © 2018 Endocrine Society.
Fornaro, Michele; Iovieno, Nadia; Clementi, Nicoletta; Boscaro, Marco; Paggi, Francesca; Balercia, Giancarlo; Fava, Maurizio; Papakostas, George I
2010-12-01
To determine the prevalence of major depressive disorder (MDD) and other selected axis-I disorders among women with newly diagnosed, untreated endocrine disorders. Two hundred and eighteen consecutive women, aged 18-65, with newly diagnosed, untreated endocrine disorders were referred for potential diagnosis of co-morbid axis-I disorders with the use of the Structured Clinical Interview for Axis I-Patient Edition (SCID-P). The SCID-P was re-administered after 12 weeks. At baseline, 64 (29.3%) women met criteria for at least one axis-I disorder. Women who were diagnosed with hyperthyroidism were more likely to meet criteria for generalized anxiety disorder and panic disorder than women without hyperthyroidism. Nine of 154 (5.8 %) women who did not meet criteria for an axis-I disorder at baseline met criteria for at least one axis-I disorder during follow-up. Among them, the presence of diabetes mellitus was statistically correlated with a higher probability of developing major depressive disorder at follow-up. Although preliminary, our findings are consistent with previous studies and suggest an increased prevalence of MDD and other axis-I disorders among women with newly diagnosed endocrine disorders, providing further evidence suggesting that women with endocrine abnormalities may be at increased risk of depression and/or anxiety disorders.
Hung, Chiao-Fang; Yeh, Po-Chen; Chung, Tien-Kan
2017-02-08
In this paper, we demonstrate a miniature magnetic-force-based, three-axis, AC magnetic sensor with piezoelectric/vibrational energy-harvesting functions. For magnetic sensing, the sensor employs a magnetic-mechanical-piezoelectric configuration (which uses magnetic force and torque, a compact, single, mechanical mechanism, and the piezoelectric effect) to convert x -axis and y -axis in-plane and z -axis magnetic fields into piezoelectric voltage outputs. Under the x -axis magnetic field (sine-wave, 100 Hz, 0.2-3.2 gauss) and the z -axis magnetic field (sine-wave, 142 Hz, 0.2-3.2 gauss), the voltage output with the sensitivity of the sensor are 1.13-26.15 mV with 8.79 mV/gauss and 1.31-8.92 mV with 2.63 mV/gauss, respectively. In addition, through this configuration, the sensor can harness ambient vibrational energy, i.e., possessing piezoelectric/vibrational energy-harvesting functions. Under x -axis vibration (sine-wave, 100 Hz, 3.5 g) and z -axis vibration (sine-wave, 142 Hz, 3.8 g), the root-mean-square voltage output with power output of the sensor is 439 mV with 0.333 μW and 138 mV with 0.051 μW, respectively. These results show that the sensor, using this configuration, successfully achieves three-axis magnetic field sensing and three-axis vibration energy-harvesting. Due to these features, the three-axis AC magnetic sensor could be an important design reference in order to develop future three-axis AC magnetic sensors, which possess energy-harvesting functions, for practical industrial applications, such as intelligent vehicle/traffic monitoring, processes monitoring, security systems, and so on.
Hung, Chiao-Fang; Yeh, Po-Chen; Chung, Tien-Kan
2017-01-01
In this paper, we demonstrate a miniature magnetic-force-based, three-axis, AC magnetic sensor with piezoelectric/vibrational energy-harvesting functions. For magnetic sensing, the sensor employs a magnetic–mechanical–piezoelectric configuration (which uses magnetic force and torque, a compact, single, mechanical mechanism, and the piezoelectric effect) to convert x-axis and y-axis in-plane and z-axis magnetic fields into piezoelectric voltage outputs. Under the x-axis magnetic field (sine-wave, 100 Hz, 0.2–3.2 gauss) and the z-axis magnetic field (sine-wave, 142 Hz, 0.2–3.2 gauss), the voltage output with the sensitivity of the sensor are 1.13–26.15 mV with 8.79 mV/gauss and 1.31–8.92 mV with 2.63 mV/gauss, respectively. In addition, through this configuration, the sensor can harness ambient vibrational energy, i.e., possessing piezoelectric/vibrational energy-harvesting functions. Under x-axis vibration (sine-wave, 100 Hz, 3.5 g) and z-axis vibration (sine-wave, 142 Hz, 3.8 g), the root-mean-square voltage output with power output of the sensor is 439 mV with 0.333 μW and 138 mV with 0.051 μW, respectively. These results show that the sensor, using this configuration, successfully achieves three-axis magnetic field sensing and three-axis vibration energy-harvesting. Due to these features, the three-axis AC magnetic sensor could be an important design reference in order to develop future three-axis AC magnetic sensors, which possess energy-harvesting functions, for practical industrial applications, such as intelligent vehicle/traffic monitoring, processes monitoring, security systems, and so on. PMID:28208693
Akopian, E S; Ter-Marganian, N G
2009-01-01
As known, all movements in the vertebral column are effected in the perpendicular planes and its training is required in all directions. Rotational movements make it possible to activate fixed spinal (thoracic, sacral) mobility, to improve their trophism and innervation and aid to interact all the spinal segments as an integral train. That is the reason why studying the rotational mobility of the vertebral column in children of school age is critically important. The algorithm developed and tested in practice was used to evaluate rotational mobility of the vertebral column (its movement about its axis) in the cervical and lumbar portions. The results of examining the rotational mobility of the cervical portion, which are fixed in all age groups, suggest that it is this spinal portion that is the most vulnerable, sensitive link that is rapidly responsive to its inadequate movements. All the above lends support to the necessity of making the special training of the cervical spine. The results of a pedagogical experiment have allowed the authors to be the first in physical educational practice to develop regional standard scales used to evaluate spinal rotational mobility in schoolchildren.
1959-11-01
Multi-Axis Test Facility, Space Progress Report, November 1, 1959: The Multi Axis Space Test Inertia Facility [MASTIF], informally referred to as the Gimbal Rig, was installed inside the Altitude Wind Tunnel. The rig, which spun on three axis simultaneously, was used to train the Mercury astronauts on how to bring a spinning spacecraft under control and to determine the effects of rapid spinning on the astronaut's eyesight and psyche. Small gaseous nitrogen jets were operated by the pilot to gain control of the rig after it had been set in motion. Part 1 shows pilot Joe Algranti in the rig as it rotates over one, two, and three axis. It also has overall views of the test set-up with researchers and technicians on the test platform. Part 2 shows Algranti being secured in the rig prior to the test. The rig is set in motion and the pilot slowly brings it under control. The Mercury astronauts trained on the MASTIF in early spring of 1960.
Compact reflection holographic recording system with high angle multiplexing
NASA Astrophysics Data System (ADS)
Kanayasu, Mayumi; Yamada, Takehumi; Takekawa, Shunsuke; Akieda, Kensuke; Goto, Akiyo; Yamamoto, Manabu
2011-02-01
Holographic memory systems have been widely researched since 1963. However, the size of the drives required and the deterioration of reconstructed data resulting from shrinkage of the medium have made practical use of a hologram memory difficult. In light of this, we propose a novel holographic recording/reconstructing system: a dual-reference beam reflection system that is smaller than conventional systems such as the off-axis or co-axis types, and which is expected to increase the number of multiplexing in angle multiplexed recording. In this multiplex recording system, two laser beams are used as reference beams, and the recorded data are reconstructed stably, even if there is shrinkage of the recording medium. In this paper, a reflection holographic memory system is explained in detail. In addition, the change in angle selectivity resulting from shrinkage of the medium is analyzed using the laminated film three-dimensional simulation method. As a result, we demonstrate that a dual-reference beam multiplex recording system is effective in reducing the influence of medium shrinkage.
ERIC Educational Resources Information Center
Nandi, Santosh; Nandi, Madhavi L.
2015-01-01
Mobility has become an important extension to the business strategies of present-day organizations. Thus, organizations are increasingly seeking managers with knowledge of value chain related to mobile-oriented business activities, usually referred to as mobile commerce (m-commerce). Accordingly, business management schools are interesting in…
Anthropometry and Standards for Wheeled Mobility: An International Comparison
ERIC Educational Resources Information Center
Steinfeld, Edward; Maisel, Jordana; Feathers, David; D'Souza, Clive
2010-01-01
Space requirements for accommodating wheeled mobility devices and their users in the built environment are key components of standards for accessible design. These requirements typically include dimensions for clear floor areas, maneuvering clearances, seat and knee clearance heights, as well as some reference dimensions on wheeled mobility device…
Intergenerational Mobility, Sibling Inequality and Borrowing Constraints.
ERIC Educational Resources Information Center
Gaviria, Alejandro
2002-01-01
Studies differences in social mobility between rich and poor families. Finds that borrowing constraints retard social mobility among the poor by preventing poor parents from investing optimally in their children's human capital. Also finds that sibling inequality appears to be independent of parental wealth. (Contains 18 references.) (Author/PKP)
NASA Astrophysics Data System (ADS)
Setterfield, T.
The rocker-bogie mobility system is a six-wheeled mobility system with the ability to equilibrate ground pressure amongst its wheels and traverse obstacles up to one wheel diameter in height; it has been used previously on NASA's Sojourner, Spirit, Opportunity and Curiosity rovers. This paper presents the mechanical design of an instrumented rocker-bogie mobility system for Kapvik, a 30 kg planetary micro-rover prototype developed for the Canadian Space Agency. The design of the wheel drive system is presented, including: motor selection, gear train selection, and performance limits. The design of a differential mechanism, which minimizes the pitch angle of the rover body, is provided. Design considerations for the integration of single-axis force sensors above the wheel hubs are presented. Structural analysis of the rocker and bogie links is outlined. The cross-hill and uphill-downhill static stability of Kapvik is investigated. Load cell and joint position data from testing during obstacle negotiation and uphill operation are presented.
JXTA: A Technology Facilitating Mobile P2P Health Management System
Rajkumar, Rajasekaran; Nallani Chackravatula Sriman, Narayana Iyengar
2012-01-01
Objectives Mobile JXTA (Juxtapose) gaining momentum and has attracted the interest of doctors and patients through P2P service that transmits messages. Audio and video can also be transmitted through JXTA. The use of mobile streaming mechanism with the support of mobile hospital management and healthcare system would enable better interaction between doctors, nurses, and the hospital. Experimental results demonstrate good performance in comparison with conventional systems. This study evaluates P2P JXTA/JXME (JXTA functionality to MIDP devices.) which facilitates peer-to-peer application+ using mobile-constraint devices. Also a proven learning algorithm was used to automatically send and process sorted patient data to nurses. Methods From December 2010 to December 2011, a total of 500 patients were referred to our hospital due to minor health problems and were monitored. We selected all of the peer groups and the control server, which controlled the BMO (Block Medical Officer) peer groups and BMO through the doctor peer groups, and prescriptions were delivered to the patient’s mobile phones through the JXTA/ JXME network. Results All 500 patients were registered in the JXTA network. Among these, 300 patient histories were referred to the record peer group by the doctors, 100 patients were referred to the external doctor peer group, and 100 patients were registered as new users in the JXTA/JXME network. Conclusion This system was developed for mobile streaming applications and was designed to support the mobile health management system using JXTA/ JXME. The simulated results show that this system can carry out streaming audio and video applications. Controlling and monitoring by the doctor peer group makes the system more flexible and structured. Enhanced studies are needed to improve knowledge mining and cloud-based M health management technology in comparison with the traditional system. PMID:24159509
46 CFR 109.105 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...
46 CFR 109.105 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...
46 CFR 109.105 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...
46 CFR 109.105 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...
46 CFR 109.105 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...
High performance magnetic bearing systems using high temperature superconductors
Abboud, Robert G.
1998-01-01
A magnetic bearing apparatus and a method for providing at least one stabilizing force in a magnetic bearing structure with a superconducting magnetic assembly and a magnetic assembly, by providing a superconducting magnetic member in the superconducting magnetic assembly with a plurality of domains and arranging said superconducting magnetic member such that at least one domain has a domain C-axis vector alignment angularly disposed relative to a reference axis of the magnetic member in the magnetic assembly.
Mobile Applications for Women's Health and Midwifery Care: A Pocket Reference for the 21st Century.
Arbour, Megan W; Stec, Melissa A
2018-05-01
Midwives and other women's health care providers are charged with providing high-quality care to women based on the most current available evidence. Quick, reliable, and accurate access to evidence-based information is essential. Numerous smartphone and mobile device applications (apps) are available to assist clinicians in providing care for women. This article discusses clinical reference apps, including those for evidence-based care guidelines, women's health care, pharmacologic reference, laboratory and diagnostic guides, as well as apps for information storage and management, electronic health records, and client education. Midwives and other clinicians are encouraged to thoughtfully integrate mobile apps into their clinical practices to improve client outcomes and clinician and client satisfaction. Although the thousands of health care apps that are available may seem daunting, this article highlights key apps that may help clinicians improve their care of women. By adding one app at a time, midwives and other women's health care providers can successfully integrate mobile apps into clinical practice. © 2018 by the American College of Nurse-Midwives.
Berger, L; Chuzel, M; Buisson, G; Rougier, P
2005-09-01
The authors investigated age-related changes in postural control in 33 healthy young adults (18-31 years), 29 seniors (62-75 years), and 22 elderly people (75-96 years). A force platform recorded the results. The horizontal motions of the center of gravity (CGh) and their difference in the plane of support CP - CGv were deduced from the complex center of pressure (CP) trajectories. With fractional Brownian modeling, one can establish that the aging process seems to induce a transition phase in which seniors take more time to initiate the corrective process in the mediolateral (ML) axis than do younger people. The elderly develop a new strategy characterized by the mobilization of higher neuromuscular energy to maintain equilibrium. In the ML axis, the larger displacements could be caused mainly by a hip strategy that could facilitate step initiation. In the anteroposterior (AP) axis, seniors and elderly individuals maintain a relative ability to stabilize their CG into the base of support compared with younger people.
46 CFR 107.115 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Incorporation by reference. 107.115 Section 107.115 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.115 Incorporation by reference. (a) The standards referred to in...
46 CFR 107.115 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Incorporation by reference. 107.115 Section 107.115 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.115 Incorporation by reference. (a) The standards referred to in...
46 CFR 107.115 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Incorporation by reference. 107.115 Section 107.115 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.115 Incorporation by reference. (a) The standards referred to in...
46 CFR 107.115 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Incorporation by reference. 107.115 Section 107.115 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.115 Incorporation by reference. (a) The standards referred to in...
46 CFR 107.115 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Incorporation by reference. 107.115 Section 107.115 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.115 Incorporation by reference. (a) The standards referred to in...
Dunbar, Donald C.; Macpherson, Jane M.; Simmons, Roger W.; Zarcades, Athina
2009-01-01
SUMMARY Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (>20deg.) and stability (≤20deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head–neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame. PMID:19043061
Dunbar, Donald C; Macpherson, Jane M; Simmons, Roger W; Zarcades, Athina
2008-12-01
Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (> 20 deg.) and stability (< or = 20 deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head-neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame.
2012-01-01
Background A mobile health unit may be useful to follow up adult and pediatric patients on antiretroviral treatment and living in remote areas devoid of laboratory facilities. The study evaluated the use of the simplified, robust, single-plateform, volumetric, pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) for CD4 T cell numeration in a mobile unit, compared against a reference flow cytometry method. Methods The therapeutic mobile unit of the Laboratoire National de Santé Hygiène Mobile, Yaoundé, Cameroon, was equipped with the Auto40. A FACSCalibur flow cytometer (Becton Dickinson Immuno-cytometry System, San Jose, CA, USA) was used as reference method. EDTA-blood samples from volunteers were first subjected to CD4 T cell count in the mobile unit, and an aliquot was sent within 4 hours to Centre International de Référence Chantal Biya, Yaoundé, for FACSCalibur assay. Results Two HIV screening campaigns with the mobile unit were organised in December 2009 and January 2010. The campaign in the suburb of Yaoundé which was 20 km from the reference laboratory included 188 volunteers comprising 93 children less than 5 years old. The campaign in Ambang Bikok (53 km far from Yaoundé) included 69 adult volunteers. In Yaoundé suburb, mean ± standard deviation (SD) CD4 T cell count was 996 ± 874 cells/μl by Auto40, and 989 ± 883 cells/μl by FACSCalibur; in Ambang Bikok, mean ± SD CD4 T cell count was 1041 ± 317 cells/μl by Auto40, and 1032 ± 294 cells/μl by FACSCalibur. Results by Auto40 and FACSCalibur were highly correlated in Yaoundé (r2 = 0.982) as in Ambang Bikok (r2 = 0.921). Bland-Altman analysis showed a close agreement between Auto40 and FACSCalibur results expressed in absolute count as in percentage in Yaoundé and Ambang Bikok. When pooling the 257 CD4 T cell count measurements, the Auto40 yielded a mean difference of +7.6 CD4 T cells/μl higher than by reference flow cytometry; and the sensitivity and specificity of Auto40 in enumerating absolute CD4 T cell counts of less than 200 cells/μl were 87% and 99%, respectively, and in enumerating absolute CD4 T cell counts of less than 350 cells/μl were 87% and 98%, respectively. The intrarun and interun precisions of the Auto40 assay assessed in the mobile unit were 5.5% and 7.9%, respectively. Conclusions The Auto40 flow cytometer installed in a therapeutic mobile unit and operated far from its reference laboratory gave a perfect correlation with the reference method, and could be useful in carrying out immunological monitoring of HIV-infected patients living in areas without access to laboratory facilities. PMID:22309994
Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon
2016-11-01
Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.
Research the mobile phone operation interfaces for vision-impairment.
Yao, Yen-Ting; Leung, Cherng-Yee
2012-01-01
Due to the vision-impaired users commonly having difficulty with mobile-phone function operations and adaption any manufacturer's user interface design, the goals for this research are established for evaluating how to improve for them the function operation convenience and user interfaces of either mobile phones or electronic appliances in the market currently. After applying collecting back 30 effective questionnaires from 30 vision-impairment, the comments have been concluded from this research include: (1) All mobile phone manufactures commonly ignorant of the vision-impairment difficulty with operating mobile phone user interfaces; (2) The vision-impairment preferential with audio alert signals; (3) The vision-impairment incapable of mobile-phone procurement independently unless with assistance from others; (4) Preferential with adding touch-usage interface design by the vision-impairment; in contrast with the least requirement for such functions as braille, enlarging keystroke size and diversifying-function control panel. With exploring the vision-impairment's necessary improvements and obstacles for mobile phone interface operation, this research is established with goals for offering reference possibly applied in electronic appliance design and . Hopefully, the analysis results of this research could be used as data references for designing electronic and high-tech products and promoting more usage convenience for those vision-impaired.
Issues Surrounding Mobility with Particular Reference to Japan.
ERIC Educational Resources Information Center
Kameoka, Yu
1996-01-01
Several issues in college student mobility between Japan and other member countries of the Organisation for Economic Cooperation and Development (OECD) are examined, including the role of organized regional mobility in various areas of the world, curriculum development to meet the needs of international students, and the need for more analysis of…
Layout Geometry in the Selection of Intrinsic Frames of Reference from Multiple Viewpoints
ERIC Educational Resources Information Center
Mou, Weimin; Zhao, Mintao; McNamara, Timothy P.
2007-01-01
Four experiments investigated the roles of layout geometry in the selection of intrinsic frames of reference in spatial memory. Participants learned the locations of objects in a room from 2 or 3 viewing perspectives. One view corresponded to the axis of bilateral symmetry of the layout, and the other view(s) was (were) nonorthogonal to the axis…
NASA Astrophysics Data System (ADS)
Zhuk, D. I.; Denisyuk, I. Yu.; Gutner, I. E.
2015-07-01
A way to construct a holographic indicator of the position of the central axis of a distant object based on recording a transmission hologram in a layer of photosensitive material and forming a remote real image before a light source is considered. A light source with a holographically formed marker designed for visual guidance to the object axis; it can be used to simplify aircraft landing on a glide path, preliminary visual alignment of large coaxial details of various machines, etc. Specific features of the scheme of recording a holographic marker and the reconstruction of its image are considered. The possibility of forming a remote holographic image marker, which can be aligned with a simultaneously operating reference laser system for determining the direction to an object and its optical axis, has been demonstrated experimentally.
Development Strategy for Mobilecommunications Market in Chinese Rural Area
NASA Astrophysics Data System (ADS)
Zhang, Liwei; Zhang, Yanjun; Xu, Liying; Li, Daoliang
Based on full analysis of rural mobile communication market, in order to explore mobile operators in rural areas of information services for sustainable development model, this paper presents three different aspects, including rural mobile communications market demand, the rural market for mobile communications business model and development strategies for rural mobile communications market research business. It supplies some valuable references for operators to develop rural users rapidly, develop the rural market effectively and to get access to develop a broad space.
Strength, mobility and falling in women referred to a geriatric outpatient clinic.
Janssen, Hennie C J P; Samson, Monique M; Meeuwsen, Ingrid B A E; Duursma, Sijmen A; Verhaar, Harald J J
2004-04-01
Mobility impairment and falling have a multifactorial etiology in frail older people. Muscle weakness is one of the risk factors and is accessible to intervention. The aim of this study was to determine the most important contributors of mobility and indicators of fall occurrence in women referred to a geriatric outpatient clinic. Mobility was assessed using the Timed 'Get-Up-and-Go' test (TGUG) and the modified Coopertest (COOP). Falling was assessed retrospectively and isometric knee extension force was measured using fixed dynamometry. Habitual physical activity was quantified using a questionnaire for the elderly. Height, weight, medical conditions and current medication were recorded. Isometric knee extension strength and habitual physical activity, which consisted predominantly of household work, were independent variables of performance on TGUG and COOP and together explained 57% of the variance in TGUG (r=0.75, p<0.001), and 64% of that in COOP, (r=0.80, p<0.001). Age, total number of medical conditions, and presence of cardiovascular disease were not significant in the model. Women in the lowest tertile of knee extension strength had a significantly higher probability of falling (0.75, 95% CI 0.56-0.91) compared with women in the highest tertile (0.27, 95% CI 0.14-0.50). Knee extension strength remains a strong determinant of mobility and fall occurrence in women referred to a geriatric outpatient clinic. Performing light to moderate household work remains independently associated with functional mobility.
A magnetic-piezoelectric smart material-structure sensing three axis DC and AC magnetic-fields
NASA Astrophysics Data System (ADS)
Hung, Chiao-Fang; Chen, Chin-Chung; Yeh, Po-Chen; Chen, Po-Wen; Chung, Tien-Kan
2017-12-01
In this paper, we demonstrate a smart material-structure can sense not only three-axis AC magnetic-fields but also three-axis DC magnetic-fields. Under x-axis and z-axis AC magnetic field ranging from 0.2 to 3.2 gauss, sensing sensitivity of the smart material-structure stimulated at resonant frequency is approximate 8.79 and 2.80 mV/gauss, respectively. In addition, under x-axis and z-axis DC magnetic fields ranging from 2 to 12 gauss, the sensitivity of the smart material-structure is 1.24-1.54 and 1.25-1.41 mV/gauss, respectively. In addition, under x-axis and z-axis DC magnetic fields ranging from 12 to 20 gauss, the sensitivity of the smart material-structure is 5.17-6.2 and 3.97-4.57 mV/gauss, respectively. These experimental results show that the smart material-structure successfully achieves three-axis DC and AC magnetic sensing as we designed. Furthermore, we also compare the results of the AC and DC magnetic-field sensing to investigate discrepancies. Finally, when applying composite magnetic-fields to the smart material-structure, the smart material-structure shows decent outputs as expected (consistent to the sensing principle). In the future, we believe the smart material-structure capable of sensing AC and DC magnetic fields will have more applications than conventional structures capable of sensing only DC or AC magnetic field. Thus, the smart material-structure will be an important design reference for future magnetic-field sensing technologies.
High performance magnetic bearing systems using high temperature superconductors
Abboud, R.G.
1998-05-05
Disclosed are a magnetic bearing apparatus and a method for providing at least one stabilizing force in a magnetic bearing structure with a superconducting magnetic assembly and a magnetic assembly, by providing a superconducting magnetic member in the superconducting magnetic assembly with a plurality of domains and arranging said superconducting magnetic member such that at least one domain has a domain C-axis vector alignment angularly disposed relative to a reference axis of the magnetic member in the magnetic assembly. 7 figs.
NASA Astrophysics Data System (ADS)
West, S. C.; Burge, J. H.; Cuerden, B.; Davison, W.; Hagen, J.; Martin, H. M.; Tuell, M. T.; Zhao, C.; Zobrist, T.
2010-07-01
The Giant Magellan Telescope has a 25 meter f/0.7 near-parabolic primary mirror constructed from seven 8.4 meter diameter segments. Several aspects of the interferometric optical test used to guide polishing of the six off-axis segments go beyond the demonstrated state of the art in optical testing. The null corrector is created from two obliquelyilluminated spherical mirrors combined with a computer-generated hologram (the measurement hologram). The larger mirror is 3.75 m in diameter and is supported at the top of a test tower, 23.5 m above the GMT segment. Its size rules out a direct validation of the wavefront produced by the null corrector. We can, however, use a reference hologram placed at an intermediate focus between the two spherical mirrors to measure the wavefront produced by the measurement hologram and the first mirror. This reference hologram is aligned to match the wavefront and thereby becomes the alignment reference for the rest of the system. The position and orientation of the reference hologram, the 3.75 m mirror and the GMT segment are measured with a dedicated laser tracker, leading to an alignment accuracy of about 100 microns over the 24 m dimensions of the test. In addition to the interferometer that measures the GMT segment, a separate interferometer at the center of curvature of the 3.75 m sphere monitors its figure simultaneously with the GMT measurement, allowing active correction and compensation for residual errors. We describe the details of the design, alignment, and use of this unique off-axis optical test.
Homography-based visual servo regulation of mobile robots.
Fang, Yongchun; Dixon, Warren E; Dawson, Darren M; Chawda, Prakash
2005-10-01
A monocular camera-based vision system attached to a mobile robot (i.e., the camera-in-hand configuration) is considered in this paper. By comparing corresponding target points of an object from two different camera images, geometric relationships are exploited to derive a transformation that relates the actual position and orientation of the mobile robot to a reference position and orientation. This transformation is used to synthesize a rotation and translation error system from the current position and orientation to the fixed reference position and orientation. Lyapunov-based techniques are used to construct an adaptive estimate to compensate for a constant, unmeasurable depth parameter, and to prove asymptotic regulation of the mobile robot. The contribution of this paper is that Lyapunov techniques are exploited to craft an adaptive controller that enables mobile robot position and orientation regulation despite the lack of an object model and the lack of depth information. Experimental results are provided to illustrate the performance of the controller.
Can the recovery of lower limb fractures be achieved by use of 3D printing mirror model?
Zhang, Wenxi; Ji, Yueping; Wang, Xinming; Liu, Jie; Li, Dong
2017-11-01
The mirror imaging 3D printing model can be used a as a reference for anatomical reduction in unilateral lower limb fractures. However, the premise of using mirror technology is that the bilateral lower limb bones are similar enough. Because one side had a fracture, it was impossible to compare this directly to the other side. Usually, surgeons think that the bilateral bones are symmetrical and use mirror technology without judging their symmetry. In patients with a unilateral lower limb bone fracture, we measured the long axis and short axis of the three selected transverse sections of the bilateral long bone for comparison to judge the symmetry of the bilateral long bones on CT images. Then, we printed a life-size normal mirror image of the long bone that is similar to the affected side. The model was used as a reference for the anatomical reduction of fractures and preoperative practice. Seventy-eight patients with lower limb bone fracture were included in this study. 24 groups of data were generated according to the same level and same axis. There were significant differences between the short axis of the left and right femoral condyle 5cm from the intercondylar keel (p=0.011), and the short axis of the distal tibia 15cm from the ankle dome (p=0.026). There was no significant difference between the left and right sides in the other 22 groups. Of all of the patients in our research, 3 patients decided to forego the surgical treatment and the operation was performed on the model instead, and the lengths of 2 patients showed deviation in actual operations, preventing anatomical reduction. The remaining 73 patients used the pre-bended plates and screws from preoperative practice in the actual operations, and postoperative X-ray examinations showed that the length of the deviation was within the permissible range. The "Comparison of long axis and short axis of three equidistant transverse sections" method makes it easy to judge the symmetry of the bilateral long bones, and prevents the blindness of preoperative planning using the contralateral mirror model directly. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pelus, Louis M; Fukuda, Seiji
2006-08-01
Chemokines direct the movement of leukocytes, including hematopoietic stem and progenitor cells, and can mobilize hematopoietic cells from marrow to peripheral blood where they can be used for transplantation. In this review, we will discuss the stem cell mobilizing activities and mechanisms of action of GRObeta, a CXC chemokine ligand for the CXCR2 receptor. GRObeta rapidly mobilizes short- and long-term repopulating cells in mice and/or monkeys and synergistically enhances mobilization responses when combined with the widely used clinical mobilizer, granulocyte colony-stimulating factor (G-CSF). The hematopoietic graft mobilized by GRObeta contains significantly more CD34(neg), Sca-1+, c-kit+, lineage(neg) (SKL) cells than the graft mobilized by G-CSF. In mice, stem cells mobilized by GRObeta demonstrate a competitive advantage upon long-term repopulation analysis and restore neutrophil and platelet counts significantly faster than cells mobilized by G-CSF. Even greater advantage in repopulation and restoration of hematopoiesis are observed with stem cells mobilized by the combination of GRObeta and G-CSF. GRObeta-mobilized SKL cells demonstrate enhanced adherence to vascular cell adhesion molecule-1 and VCAM(pos) endothelial cells and home more efficiently to bone marrow in vivo. The marrow homing ability of GRObeta-mobilized cells is less dependent on the CXCR4/SDF-1 axis than cells mobilized by G-CSF. The mechanism of mobilization by GRObeta requires active matrix metalloproteinase-9 (MMP-9), which results from release of pro-MMP-9 from peripheral blood, and marrow neutrophils, which alters the stoichiometry between pro-MMP-9 and its inhibitor tissue inhibitor of metalloproteinase-1, resulting in MMP-9 activation. The efficacy and rapid action of GRObeta and lack of proinflammatory activity make it an attractive agent to supplement mobilization by G-CSF. In addition, GRObeta may also have clinical mobilizing efficacy on its own, reducing the overall time and costs associated with peripheral blood stem cell transplantation.
Superenergy flux of Einstein-Rosen waves
NASA Astrophysics Data System (ADS)
Domínguez, P. J.; Gallegos, A.; Macías-Díaz, J. E.; Vargas-Rodríguez, H.
In this work, we consider the propagation speed of the superenergy flux associated to the Einstein-Rosen cylindrical waves propagating in vacuum and over the background of the gravitational field of an infinitely long mass line distribution. The velocity of the flux is determined considering the reference frame in which the super-Poynting vector vanishes. This reference frame is then considered as comoving with the flux. The explicit expressions for the velocities are given with respect to a reference frame at rest with the symmetry axis.
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry
Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-01
Background Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. Objective This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Methods Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. Results A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. Conclusions The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. PMID:29321124
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry.
Masalski, Marcin; Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-10
Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. ©Marcin Masalski, Tomasz Grysiński, Tomasz Kręcicki. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 10.01.2018.
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
Copper excess impairs mobilization of storage proteins in bean cotyledons.
Karmous, Inès; El Ferjani, Ezzedine; Chaoui, Abdelilah
2011-12-01
Germination represents a limiting stage of plant life cycle. One of the underlying metabolic activities following imbibition of seed is the reserve mobilization. Seeds of bean (Phaseolus vulgaris L. var. soisson nain hatif) were germinated by soaking in distilled water or 200 μM CuCl(2). Storage proteins breakdown and amino acids freeing from reserve tissues were investigated. Compared to the control, Cu caused a reduction in germination rate, embryo growth, and in mobilization of cotyledonary biomass. The failure in albumin and globulin hydrolysis after the exposure to the pollutant was argued by (1) higher contents of remaining proteins than control ones, (2) persistence of some polypeptide bands resolved by polyacrylamide gel electrophoresis of albumin and globulin-rich fractions, and (3) decrease in the availability of amino acids. Nitrogen starvation in embryonic axis should be associated with the Cu-imposed delay in growth.
ERIC Educational Resources Information Center
Altshuler, Ken
1994-01-01
Presents a method using art classics to teach that a third vector axis is required to represent orientations in three-dimensional space. Helps students understand the importance of perspective, frame of reference, balance, and color theory. (MVL)
Functional integrity of the interrenal tissue of yellow perch from contaminated sites tested in vivo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girard, C.; Brodeur, J.C.; Hontela, A.
1995-12-31
The normal activation of the hypothalamo-pituitary-interrenal axis (HPI axis) in response to capture is disrupted in fish subjected to life-long exposure to heavy metals, PCBs and PAHs. The ability to increase plasma cortisol in yellow perch (Perca flavescens) from sites contaminated by heavy metals and organic compounds, and from a reference site was assessed by the Capture stress test and by the ACTH Challenge test, a new standardized in vivo method designed for field studies. The effects of seasonal factors, such as temperature and gonadal maturity on these tests were investigated. Measures of liver and muscle glycogen and histopathology weremore » made to further characterize the biochemical and structural changes that may occur along with hormonal changes. The Capture stress test showed that an acute source of stress induced a lower cortisol response in fish from the highly contaminated site compared to the reference site, revealing a functional impairment of the HPI axis. The ACTH Challenge test showed that the hormonal responsiveness of the cortisol-secreting interrenal tissue, stimulated by a standard dose of ACTH injected i.p., was lower in fish from the highly contaminated site than the reference site. Spring is the season during which the impairment was the most evident. The possibility of using the reduced capacity of feral fish to respond to a standardized ACTH Challenge as an early bioindicator of toxic stress is discussed.« less
NASA Astrophysics Data System (ADS)
Yang, C. L.; Du, R. R.; Pfeiffer, L. N.; West, K. W.
2006-07-01
Using a two-axis magnet, we have studied experimentally the influence of a parallel magnetic field (B//) on microwave-induced resistance oscillations (MIROs) and zero-resistance states (ZRS) previously discovered in a high-mobility two-dimensional electron system. We have observed a strong suppression of MIRO/ZRS by a modest B//˜1T . In Hall bar samples, magnetoplasmon resonance (MPR) has also been observed concurrently with the MIRO/ZRS. In contrast to the suppression of MIRO/ZRS, the MPR peak is apparently enhanced by B// . These findings cannot be explained by a simple modification of single-particle energy spectrum and/or scattering parameters by B// .
Chemical disorder as an engineering tool for spin polarization in Mn3Ga -based Heusler systems
NASA Astrophysics Data System (ADS)
Chadov, S.; D'Souza, S. W.; Wollmann, L.; Kiss, J.; Fecher, G. H.; Felser, C.
2015-03-01
Our study highlights spin-polarization mechanisms in metals by focusing on the mobilities of conducting electrons with different spins instead of their quantities. Here, we engineer electron mobility by applying chemical disorder induced by nonstoichiometric variations. As a practical example, we discuss the scheme that establishes such variations in tetragonal Mn3Ga Heusler material. We justify this approach using first-principles calculations of the spin-projected conductivity components based on the Kubo-Greenwood formalism. It follows that, in the majority of cases, even a small substitution of some other transition element instead of Mn may lead to a substantial increase in spin polarization along the tetragonal axis.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-05
... Decree in United States v. Exxon Mobil Corporation, et al., C.A. No. 4:11-cv-01037 (S.D. Tex.), was... as defendants Exxon Mobil Corporation, Ashland, Inc., Eurecat U.S. Incorporated, Akzo Nobel, Inc... Justice, Washington, DC 20044-7611, and should refer to United States v. Exxon Mobil Corporation, et al...
ERIC Educational Resources Information Center
Dervin, Fred
2009-01-01
Study abroad is often referred to, first and foremost, as an intercultural experience during which "cultures" are encountered and for which mobile students should be prepared. This article, which is based on research carried out on various aspects of student mobility in Europe, and more precisely in Finland, aims to go beyond the…
Mobile Technology: Implications of Its Application on Learning
ERIC Educational Resources Information Center
Adeyemo, Samuel Adesola; Adedoja, Gloria Olusola; Adelore, Omobola
2013-01-01
Learning in Nigeria is considered to have taken a new dimension as the Distance Learning Centre (DLC) of the University of Ibadan has created wider access to learning through the application of mobile technology to learning with particular reference to mobile phones use for the teaching and learning process. By this, the Centre seeks to achieve…
Barriers to International Student Mobility: Evidence from the Erasmus Program
ERIC Educational Resources Information Center
Souto-Otero, Manuel; Huisman, Jeroen; Beerkens, Maarja; de Wit, Hans; Vujic, Suncica
2013-01-01
In this article, we look at the barriers to international student mobility, with particular reference to the European Erasmus program. Much is known about factors that support or limit student mobility, but very few studies have made comparisons between participants and nonparticipants. Making use of a large data set on Erasmus and non-Erasmus…
NASA Astrophysics Data System (ADS)
Kurzych, A.; Kowalski, J. K.; Sakowicz, B.; Krajewski, Z.; Jaroszewicz, L. R.
2016-09-01
The main objective of this work is to characterize the performance of an interferometric fibre sensor which has been designed in order to register rotational phenomena, both in seismological observatories and engineering constructions. It is based on a well-known Sagnac effect which enables to detect one-axis rotational motions in a direct way and without any reference system. The presented optical fibre sensor - FOSREM allows to measure a component of rotation in a wide range of signal amplitude form 10-8 rad/s to 10 rad/s, as well as frequency from 0 Hz to the upper frequency from 2.56 Hz to 328.12 Hz. The laboratory investigation of our system indicated that it keeps theoretical sensitivity equal to 2·10-8 rad/s/Hz1/2 and accuracy no less than 3·1-8 to 1.6·10-6 rad/s in the above mentioned frequency band. Moreover, system size that equals 0.36×0.36×0.16 m and opportunity to remotely control the system via Internet by special server make FOSREM a mobile and autonomous device.
NASA Astrophysics Data System (ADS)
Pástor, P.
2016-07-01
The equations of secular evolution for dust grains in mean motion resonances with a planet are solved for stationary points. Non-gravitational effects caused by stellar radiation (the Poynting-Robertson effect and the stellar wind) are taken into account. The solutions are stationary in the semimajor axis, eccentricity and resonant angle, but allow the pericentre to advance. The semimajor axis of stationary solutions can be slightly shifted from the exact resonant value. The periodicity of the stationary solutions in a reference frame orbiting with the planet is proved analytically. The existence of periodic solutions in mean motion resonances means that analytical theory enables infinitely long capture times for dust particles. The stationary solutions are periodic motions to which the eccentricity asymptotically approaches and around which the libration occurs. Initial conditions corresponding to the stationary solutions are successfully found by numerically integrating the equation of motion. Numerically and analytically determined shifts of the semimajor axis from the exact resonance for the stationary solutions are in excellent agreement. The stationary solutions can be plotted by the locations of pericentres in the reference frame orbiting with the planet. The pericentres are distributed in space according to the properties of the dust particles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, Michael R; Sengupta, Manajit; Vignola, Frank
A variety of sensors are studied on a one-axis tracking surface and a horizontal surface in Golden, Colorado, and Eugene, Oregon. This is the first year of a long-term study that will look at not only a comparison between the instruments but also the longer-term degradation in calibration and/or performance. Initially, results from each location will be analyzed, and then results will be compared and contrasted between the two locations. A quick comparison at Eugene indicates that reference solar cells seem to compare better against a secondary standard pyranometer on a one-axis tracker than photodiode-based pyranometers. More study is neededmore » to characterize and confirm this finding.« less
Klyachkin, Yuri M.; Karapetyan, Anush V.; Ratajczak, Mariusz Z.; Abdel-Latif, Ahmed
2014-01-01
Despite significant advances in medical therapy and interventional strategies, the prognosis of millions of patients with acute myocardial infarction (AMI) and ischemic heart disease (IHD) remains poor. Currently, short of heart transplantation with all of its inherit limitations, there are no available treatment strategies that replace the infarcted myocardium. It is now well established that cardiomyocytes undergo continuous renewal, with contribution from bone marrow (BM)-derived stem/progenitor cells (SPCs). This phenomenon is upregulated during AMI by initiating multiple innate reparatory mechanisms through which BMSPCs are mobilized towards the ischemic myocardium and contribute to myocardial regeneration. While a role for the SDF-1/CXCR4 axis in retention of BMSPCs in bone marrow is undisputed, its exclusive role in their mobilization and homing to a highly proteolytic microenvironment, such as the ischemic/infarcted myocardium, is currently being challenged. Recent evidence suggests a pivotal role for bioactive lipids in the mobilization of BMSPCs at the early stages following AMI and their homing towards ischemic myocardium. This review highlights the recent advances in our understanding of the mechanisms of stem cell mobilization, provides newer evidence implicating bioactive lipids in BMSPC mobilization and differentiation, and discusses their potential as therapeutic agents in the treatment of IHD. PMID:24672794
[Progress in research of mobile health intervention].
Huang, Z; Ning, P S; Cheng, P X; Hu, G Q
2016-10-10
With the rapid development of mobile communication technology and the growing popularity of smartphones worldwide, mobile health has become an extension of e-Health and Tele-Health, and is of value in the research and practice of public health. In this paper, we systematically assessed research literature of mobile health' s application on disease prevention and control as well as health promotion. Based on the characteristics of current literature, this paper focused on the application of mobile health in maternal health promotion, chronic disease management, and communicable disease prevention and control to provide reference for the mobile health intervention research in China.
Large-aperture interferometer using local reference beam
NASA Technical Reports Server (NTRS)
Howes, W. L.
1982-01-01
A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed.
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
Modeling the hypothalamus-pituitary-adrenal axis: A review and extension.
Hosseinichimeh, Niyousha; Rahmandad, Hazhir; Wittenborn, Andrea K
2015-10-01
Multiple models of the hypothalamus-pituitary-adrenal (HPA) axis have been developed to characterize the oscillations seen in the hormone concentrations and to examine HPA axis dysfunction. We reviewed the existing models, then replicated and compared five of them by finding their correspondence to a dataset consisting of ACTH and cortisol concentrations of 17 healthy individuals. We found that existing models use different feedback mechanisms, vary in the level of details and complexities, and offer inconsistent conclusions. None of the models fit the validation dataset well. Therefore, we re-calibrated the best performing model using partial calibration and extended the model by adding individual fixed effects and an exogenous circadian function. Our estimated parameters reduced the mean absolute percent error significantly and offer a validated reference model that can be used in diverse applications. Our analysis suggests that the circadian and ultradian cycles are not created endogenously by the HPA axis feedbacks, which is consistent with the recent literature on the circadian clock and HPA axis. Copyright © 2015 Elsevier Inc. All rights reserved.
On the Long-Term "Hesitation Waltz" Between the Earth's Figure and Rotation Axes
NASA Astrophysics Data System (ADS)
Couhert, A.; Mercier, F.; Bizouard, C.
2017-12-01
The principal figure axis of the Earth refers to its axis of maximum inertia. In the absence of external torques, the latter should closely coincide with the rotation pole, when averaged over many years. However, because of tidal and non-tidal mass redistributions within the Earth system, the rotational axis executes a circular motion around the figure axis essentially at seasonal time scales. In between, it is not clear what happens at decadal time spans and how well the two axes are aligned. The long record of accurate Satellite Laser Ranging (SLR) observations to Lageos makes possible to directly measure the long time displacement of the figure axis with respect to the crust, through the determination of the degree 2 order 1 geopotential coefficients for the 34-year period 1983-2017. On the other hand, the pole coordinate time series (mainly from GNSS and VLBI data) yield the motion of the rotation pole with even a greater accuracy. This study is focused on the analysis of the long-term behavior of the two time series, as well as the derivation of possible explanations for their discrepancies.
Global plate motion frames: Toward a unified model
NASA Astrophysics Data System (ADS)
Torsvik, Trond H.; Müller, R. Dietmar; van der Voo, Rob; Steinberger, Bernhard; Gaina, Carmen
2008-09-01
Plate tectonics constitutes our primary framework for understanding how the Earth works over geological timescales. High-resolution mapping of relative plate motions based on marine geophysical data has followed the discovery of geomagnetic reversals, mid-ocean ridges, transform faults, and seafloor spreading, cementing the plate tectonic paradigm. However, so-called "absolute plate motions," describing how the fragments of the outer shell of the Earth have moved relative to a reference system such as the Earth's mantle, are still poorly understood. Accurate absolute plate motion models are essential surface boundary conditions for mantle convection models as well as for understanding past ocean circulation and climate as continent-ocean distributions change with time. A fundamental problem with deciphering absolute plate motions is that the Earth's rotation axis and the averaged magnetic dipole axis are not necessarily fixed to the mantle reference system. Absolute plate motion models based on volcanic hot spot tracks are largely confined to the last 130 Ma and ideally would require knowledge about the motions within the convecting mantle. In contrast, models based on paleomagnetic data reflect plate motion relative to the magnetic dipole axis for most of Earth's history but cannot provide paleolongitudes because of the axial symmetry of the Earth's magnetic dipole field. We analyze four different reference frames (paleomagnetic, African fixed hot spot, African moving hot spot, and global moving hot spot), discuss their uncertainties, and develop a unifying approach for connecting a hot spot track system and a paleomagnetic absolute plate reference system into a "hybrid" model for the time period from the assembly of Pangea (˜320 Ma) to the present. For the last 100 Ma we use a moving hot spot reference frame that takes mantle convection into account, and we connect this to a pre-100 Ma global paleomagnetic frame adjusted 5° in longitude to smooth the reference frame transition. Using plate driving force arguments and the mapping of reconstructed large igneous provinces to core-mantle boundary topography, we argue that continental paleolongitudes can be constrained with reasonable confidence.
Day, Yuan-Ji
2016-01-01
We examined the role of tissue plasminogen activator- (tPA-) matrix metalloproteinase- (MMP-) 9 in mobilizing endothelial progenitor cells (EPCs) from bone marrow to circulation and critical limb ischemia (CLI) region. Male C57BL/6J mice having been irradiated were categorized into wild-type mice (WT) receiving WT bone marrow cell (BMC) transfusion (group 1), WT mice receiving MMP-9 knockout (MMP-9−/−) BMC (group 2), MMP-9−/− receiving MMP-9−/− BMC (group 3), and MMP-9−/− receiving WT BMC (group 4), each of which was subdivided into sham control (SC), CLI, SC-tPA, and CLI-tPA. In groups 1 and 4, by post-CLI 18 h and day 14, circulating EPC (C-kit+/CD31+, Sca-1+/KDR+) levels were highest in CLI-tPA subgroup. In groups 2 and 3, EPC levels did not differ among all subgroups. The EPC levels in bone marrow were higher in groups 2 and 3 than those in groups 1 and 4. By day 14, in animals with CLI, expression levels of proangiogenic factors (CXCR4, SDF-1α, and VEGF) showed similar trends as circulating EPC levels. Moreover, the number of infiltrated neutrophils and macrophages in quadriceps was higher in groups 1 and 4 than groups in 2 and 3. In conclusion, tPA-MMP-9 axis plays a crucial role in EPC mobilization and angiogenesis in experimental CLI. PMID:27610138
Algorithms for Automatic Alignment of Arrays
NASA Technical Reports Server (NTRS)
Chatterjee, Siddhartha; Gilbert, John R.; Oliker, Leonid; Schreiber, Robert; Sheffler, Thomas J.
1996-01-01
Aggregate data objects (such as arrays) are distributed across the processor memories when compiling a data-parallel language for a distributed-memory machine. The mapping determines the amount of communication needed to bring operands of parallel operations into alignment with each other. A common approach is to break the mapping into two stages: an alignment that maps all the objects to an abstract template, followed by a distribution that maps the template to the processors. This paper describes algorithms for solving the various facets of the alignment problem: axis and stride alignment, static and mobile offset alignment, and replication labeling. We show that optimal axis and stride alignment is NP-complete for general program graphs, and give a heuristic method that can explore the space of possible solutions in a number of ways. We show that some of these strategies can give better solutions than a simple greedy approach proposed earlier. We also show how local graph contractions can reduce the size of the problem significantly without changing the best solution. This allows more complex and effective heuristics to be used. We show how to model the static offset alignment problem using linear programming, and we show that loop-dependent mobile offset alignment is sometimes necessary for optimum performance. We describe an algorithm with for determining mobile alignments for objects within do loops. We also identify situations in which replicated alignment is either required by the program itself or can be used to improve performance. We describe an algorithm based on network flow that replicates objects so as to minimize the total amount of broadcast communication in replication.
Visualizing Mobility of Public Transportation System.
Zeng, Wei; Fu, Chi-Wing; Arisona, Stefan Müller; Erath, Alexander; Qu, Huamin
2014-12-01
Public transportation systems (PTSs) play an important role in modern cities, providing shared/massive transportation services that are essential for the general public. However, due to their increasing complexity, designing effective methods to visualize and explore PTS is highly challenging. Most existing techniques employ network visualization methods and focus on showing the network topology across stops while ignoring various mobility-related factors such as riding time, transfer time, waiting time, and round-the-clock patterns. This work aims to visualize and explore passenger mobility in a PTS with a family of analytical tasks based on inputs from transportation researchers. After exploring different design alternatives, we come up with an integrated solution with three visualization modules: isochrone map view for geographical information, isotime flow map view for effective temporal information comparison and manipulation, and OD-pair journey view for detailed visual analysis of mobility factors along routes between specific origin-destination pairs. The isotime flow map linearizes a flow map into a parallel isoline representation, maximizing the visualization of mobility information along the horizontal time axis while presenting clear and smooth pathways from origin to destinations. Moreover, we devise several interactive visual query methods for users to easily explore the dynamics of PTS mobility over space and time. Lastly, we also construct a PTS mobility model from millions of real passenger trajectories, and evaluate our visualization techniques with assorted case studies with the transportation researchers.
Smoking Cessation: Services and Applications for Mobile Devices.
Kefaliakos, Antonios; Pliakos, Ioannis; Chardalias, Kostis; Charalampidou, Martha; Diomidous, Marianna
2016-01-01
The aim of this review is to present mobile health applications which help individuals to change their smoking habit. An online search on scientific databases and mobile application stores was conducted to collect information about m-Health and the smoking cessation. 12 papers found discussing about mobile applications and solutions for quit smoking referred to 4 different technological approaches. Based on the research results, mobile devices and their applications constitute an excellent mean that can help smokers by providing counseling and give them the necessary motivation to smoking cessation.
Hunt, Brady; Fregnani, José Humberto Tavares Guerreiro; Schwarz, Richard A; Pantano, Naitielle; Tesoni, Suelen; Possati-Resende, Júlio César; Antoniazzi, Marcio; de Oliveira Fonseca, Bruno; de Macêdo Matsushita, Graziela; Scapulatempo-Neto, Cristovam; Kerr, Ligia; Castle, Philip E; Schmeler, Kathleen; Richards-Kortum, Rebecca
2018-06-01
Cervical cancer is a leading cause of death in underserved areas of Brazil. This prospective randomized trial involved 200 women in southern/central Brazil with abnormal Papanicolaou tests. Participants were randomized by geographic cluster and referred for diagnostic evaluation either at a mobile van upon its scheduled visit to their local community, or at a central hospital. Participants in both arms underwent colposcopy, in vivo microscopy, and cervical biopsies. We compared rates of diagnostic follow-up completion between study arms, and also evaluated the diagnostic performance of in vivo microscopy compared with colposcopy. There was a 23% absolute and 37% relative increase in diagnostic follow-up completion rates for patients referred to the mobile van (102/117, 87%) compared with the central hospital (53/83, 64%; P = 0.0001; risk ratio = 1.37, 95% CI, 1.14-1.63). In 229 cervical sites in 144 patients, colposcopic examination identified sites diagnosed as cervical intraepithelial neoplasia grade 2 or more severe (CIN2+; 85 sites) with a sensitivity of 94% (95% CI, 87%-98%) and specificity of 50% (95% CI, 42%-58%). In vivo microscopy with real-time automated image analysis identified CIN2+ with a sensitivity of 92% (95% CI, 84%-97%) and specificity of 48% (95% CI, 40%-56%). Women referred to the mobile van were more likely to complete their diagnostic follow-up compared with those referred to a central hospital, without compromise in clinical care. In vivo microscopy in a mobile van provides automated diagnostic imaging with sensitivity and specificity similar to colposcopy. Cancer Prev Res; 11(6); 359-70. ©2018 AACR . ©2018 American Association for Cancer Research.
Practical wavelength calibration considerations for UV-visible Fourier-transform spectroscopy.
Salit, M L; Travis, J C; Winchester, M R
1996-06-01
The intrinsic wavelength scale in a modern reference laser-controlled Michelson interferometer-sometimes referred to as the Connes advantage-offers excellent wavelength accuracy with relative ease. Truly superb wavelength accuracy, with total relative uncertainty in line position of the order of several parts in 10(8), should be within reach with single-point, multiplicative calibration. The need for correction of the wavelength scale arises from two practical effects: the use of a finite aperture, from which off-axis rays propagate through the interferometer, and imperfect geometric alignment of the sample beam with the reference beam and the optical axis of the moving mirror. Although an analytical correction can be made for the finite-aperture effect, calibration with a trusted wavelength standard is typically used to accomplish both corrections. Practical aspects of accurate calibration of an interferometer in the UV-visible region are discussed. Critical issues regarding accurate use of a standard external to the sample source and the evaluation and selection of an appropriate standard are addressed. Anomalous results for two different potential wavelength standards measured by Fabry-Perot interferometry (Ar II and (198)Hg I) are observed.
MTPA control of mechanical sensorless IPMSM based on adaptive nonlinear control.
Najjar-Khodabakhsh, Abbas; Soltani, Jafar
2016-03-01
In this paper, an adaptive nonlinear control scheme has been proposed for implementing maximum torque per ampere (MTPA) control strategy corresponding to interior permanent magnet synchronous motor (IPMSM) drive. This control scheme is developed in the rotor d-q axis reference frame using adaptive input-output state feedback linearization (AIOFL) method. The drive system control stability is supported by Lyapunov theory. The motor inductances are online estimated by an estimation law obtained by AIOFL. The estimation errors of these parameters are proved to be asymptotically converged to zero. Based on minimizing the motor current amplitude, the MTPA control strategy is performed by using the nonlinear optimization technique while considering the online reference torque. The motor reference torque is generated by a conventional rotor speed PI controller. By performing MTPA control strategy, the generated online motor d-q reference currents were used in AIOFL controller to obtain the SV-PWM reference voltages and the online estimation of the motor d-q inductances. In addition, the stator resistance is online estimated using a conventional PI controller. Moreover, the rotor position is detected using the online estimation of the stator flux and online estimation of the motor q-axis inductance. Simulation and experimental results obtained prove the effectiveness and the capability of the proposed control method. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Spherical grating monochromator with interferometer control and in-vacuum reference
NASA Astrophysics Data System (ADS)
Holly, D. J.; Mason, W. P.; Sailor, T.; Smith, R. E.; Wahl, D.
2002-03-01
Physical Science Laboratory's new generation of spherical grating monochromators incorporates a laser interferometer to control scan angle and an in-vacuum absolute angle reference, as well as other improvements. The design accommodates up to six gratings which can be moved axially (under motor control, with encoder position readback) at any scan angle. The gratings are cooled by means of spring-loaded clamps which conduct heat to a water-cooled plate. The instruments feature hollow roller bearings on the scan axis to minimize bearing runout, and a pseudosine-bar drive for precise control of grating angle. The interferometer angle-measuring optics are mounted inside the vacuum chamber and measure the angle between the grating scan axis and the instrument's granite base. The laser interferometer measures the grating angle with a resolution of approximately 0.02 arcsec over the entire scan range of 40°. To provide a reference for the interferometer angle measurement, we have built an in-vacuum optical reference which uses custom chrome-on-glass reticles mounted inside the vacuum chamber. Collimated light from a source outside the vacuum passes through the reticles to yield quadrature signals which precisely define an absolute reference angle for the interferometer. Repeatability of the grating angle is within a range of ±0.05 arcsec. Two of these instruments are in operation at SRRC (Taiwan) and a third instrument has been delivered to NSLS (Brookhaven).
Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, Michael R; Sengupta, Manajit; Vignola, Frank
Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focusesmore » on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.« less
Techno-economic assessment of the Mobil Two-Stage Slurry Fischer-Tropsch/ZSM-5 process
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Sawy, A.; Gray, D.; Neuworth, M.
1984-11-01
A techno-economic assessment of the Mobil Two-Stage Slurry Fischer-Tropsch reactor system was carried out. Mobil bench-scale data were evaluated and scaled to a commercial plant design that produced specification high-octane gasoline and high-cetane diesel fuel. Comparisons were made with three reference plants - a SASOL (US) plant using dry ash Lurgi gasifiers and Synthol synthesis units, a modified SASOL plant with a British Gas Corporation slagging Lurgi gasifier (BGC/Synthol) and a BGC/slurry-phase process based on scaled data from the Koelbel Rheinpreussen-Koppers plant. A conceptual commercial version of the Mobil two-stage process shows a higher process efficiency than a SASOL (US)more » and a BGC/Synthol plant. The Mobil plant gave lower gasoline costs than obtained from the SASOL (US) and BGC/Synthol versions. Comparison with published data from a slurry-phase Fischer-Tropsch (Koelbel) unit indicated that product costs from the Mobil process were within 6% of the Koelbel values. A high-wax version of the Mobil process combined with wax hydrocracking could produce gasoline and diesel fuel at comparable cost to the lowest values achieved from prior published slurry-phase results. 27 references, 18 figures, 49 tables.« less
The Longitudinal Impact of Cognitive Speed of Processing Training on Driving Mobility
Edwards, Jerri D.; Myers, Charlsie; Ross, Lesley A.; Roenker, Daniel L.; Cissell, Gayla M.; McLaughlin, Alexis M.; Ball, Karlene K.
2009-01-01
Purpose: To examine how cognitive speed of processing training affects driving mobility across a 3-year period among older drivers. Design and Methods: Older drivers with poor Useful Field of View (UFOV) test performance (indicating greater risk for subsequent at-fault crashes and mobility declines) were randomly assigned to either a speed of processing training or a social and computer contact control group. Driving mobility of these 2 groups was compared with a group of older adults who did not score poorly on the UFOV test (reference group) across a 3-year period. Results: Older drivers with poor UFOV test scores who did not receive training experienced greater mobility declines as evidenced by decreased driving exposure and space and increased driving difficulty at 3 years. Those at risk for mobility decline who received training did not differ across the 3-year period from older adults in the reference group with regard to driving exposure, space, and most aspects of driving difficulty. Implications: Cognitive speed of processing training can not only improve cognitive performance but also protect against mobility declines among older drivers. Scientifically proven cognitive training regimens have the potential to enhance the everyday lives of older adults. PMID:19491362
Wang, Hong-Xing; Wang, Yu-Ping
2016-01-01
Objective: To systematically review the updated information about the gut microbiota-brain axis. Data Sources: All articles about gut microbiota-brain axis published up to July 18, 2016, were identified through a literature search on PubMed, ScienceDirect, and Web of Science, with the keywords of “gut microbiota”, “gut-brain axis”, and “neuroscience”. Study Selection: All relevant articles on gut microbiota and gut-brain axis were included and carefully reviewed, with no limitation of study design. Results: It is well-recognized that gut microbiota affects the brain's physiological, behavioral, and cognitive functions although its precise mechanism has not yet been fully understood. Gut microbiota-brain axis may include gut microbiota and their metabolic products, enteric nervous system, sympathetic and parasympathetic branches within the autonomic nervous system, neural-immune system, neuroendocrine system, and central nervous system. Moreover, there may be five communication routes between gut microbiota and brain, including the gut-brain's neural network, neuroendocrine-hypothalamic-pituitary-adrenal axis, gut immune system, some neurotransmitters and neural regulators synthesized by gut bacteria, and barrier paths including intestinal mucosal barrier and blood-brain barrier. The microbiome is used to define the composition and functional characteristics of gut microbiota, and metagenomics is an appropriate technique to characterize gut microbiota. Conclusions: Gut microbiota-brain axis refers to a bidirectional information network between the gut microbiota and the brain, which may provide a new way to protect the brain in the near future. PMID:27647198
Al-implanted on-axis 4H-SiC MOSFETs
NASA Astrophysics Data System (ADS)
Florentin, M.; Cabello, M.; Rebollo, J.; Montserrat, J.; Brosselard, P.; Henry, A.; Godignon, P.
2017-03-01
In this paper, the impact of temperature and time stress on gate oxide stability of several multi-implanted and epitaxied 4H-SiC nMOSFET is presented. The oxide layer was processed under a rapid thermal process (RTP) furnace. The variation of the main electrical parameters is shown. We report the high quality and stability of such implanted MOSFETs, and point out the very low roughness effect of the on-axis-cut sample. Particularly, in the best case, effective channel mobility (μ fe) overcomes 20 cm2.V-1.s-1 at 300 °C for a channel length of 12 μm, which is very encouraging for implantation technology. Starting from 200 °C, the apparent increase of the μ fe peak of the MOSFET ceases and tends to saturate with further temperature increase. This is an indication of the potential of MOSFETs built on on-axis substrates. Thus, starting from the real case of an implanted MOSFET, the global purpose is to show that the electrical performance of such an on-axis-built device can tend to reach that of the ideal case, i.e. epitaxied MOSFET, and even overcome its electrical limitation, e.g. in terms of threshold voltage stability at high temperature.
Transportation management center data capture for performance and mobility measures guidebook.
DOT National Transportation Integrated Search
2013-03-01
The Guide to Transportation Management Center (TMC) Data Capture for Performance and Mobility Measures is a two-volume document consisting of this summary Guidebook and a Reference Manual. These documents provide technical guidance and recommended pr...
Mobile Robot Self-Localization by Matching Range Maps Using a Hausdorff Measure
NASA Technical Reports Server (NTRS)
Olson, C. F.
1997-01-01
This paper examines techniques for a mobile robot to perform self-localization in natural terrain by comparing a dense range map computed from stereo imagery to a range map in a known frame of reference.
Johnson, T S; Andriacchi, T P; Erdman, A G
2004-01-01
Various uses of the screw or helical axis have previously been reported in the literature in an attempt to quantify the complex displacements and coupled rotations of in vivo human knee kinematics. Multiple methods have been used by previous authors to calculate the axis parameters, and it has been theorized that the mathematical stability and accuracy of the finite helical axis (FHA) is highly dependent on experimental variability and rotation increment spacing between axis calculations. Previous research has not addressed the sensitivity of the FHA for true in vivo data collection, as required for gait laboratory analysis. This research presents a controlled series of experiments simulating continuous data collection as utilized in gait analysis to investigate the sensitivity of the three-dimensional finite screw axis parameters of rotation, displacement, orientation and location with regard to time step increment spacing, utilizing two different methods for spatial location. Six-degree-of-freedom motion parameters are measured for an idealized rigid body knee model that is constrained to a planar motion profile for the purposes of error analysis. The kinematic data are collected using a multicamera optoelectronic system combined with an error minimization algorithm known as the point cluster method. Rotation about the screw axis is seen to be repeatable, accurate and time step increment insensitive. Displacement along the axis is highly dependent on time step increment sizing, with smaller rotation angles between calculations producing more accuracy. Orientation of the axis in space is accurate with only a slight filtering effect noticed during motion reversal. Locating the screw axis by a projected point onto the screw axis from the mid-point of the finite displacement is found to be less sensitive to motion reversal than finding the intersection of the axis with a reference plane. A filtering effect of the spatial location parameters was noted for larger time step increments during periods of little or no rotation.
Chiarella, Deborah
2016-01-01
The University at Buffalo Health Sciences Library provides reference and instructional services to support research, curricular, and clinical programs of the University at Buffalo. With funding from an NN/LM MAR Technology Improvement Award, the University at Buffalo Health Sciences Library (UBHSL) purchased iPads to develop embedded reference and educational services. Usage statistics were collected over a ten-month period to measure the frequency of iPad use for mobile services. While this experiment demonstrates that the iPad can be used to meet the library user's needs outside of the physical library space, this paper will also offer advice for others who are considering implementing their own program. PMID:26496394
Stellrecht, Elizabeth; Chiarella, Deborah
2015-01-01
The University at Buffalo Health Sciences Library provides reference and instructional services to support research, curricular, and clinical programs of the University at Buffalo. With funding from an NN/LM MAR Technology Improvement Award, the University at Buffalo Health Sciences Library (UBHSL) purchased iPads to develop embedded reference and educational services. Usage statistics were collected over a ten-month period to measure the frequency of iPad use for mobile services. While this experiment demonstrates that the iPad can be used to meet the library user's needs outside of the physical library space, this article will also offer advice for others who are considering implementing their own program.
Method and apparatus for electron-only radiation detectors from semiconductor materials
Lund, James C.
2000-01-01
A system for obtaining improved resolution in room temperature semiconductor radiation detectors such as CdZnTe and Hgl.sub.2, which exhibit significant hole-trapping. A electrical reference plane is established about the perimeter of a semiconductor crystal and disposed intermediately between two oppositely biased end electrodes. The intermediate reference plane comprises a narrow strip of wire in electrical contact with the surface of the crystal, biased at a potential between the end electrode potentials and serving as an auxiliary electrical reference for a chosen electrode--typically the collector electrode for the more mobile charge carrier. This arrangement eliminates the interfering effects of the less mobile carriers as these are gathered by their electrode collector.
Are Reference Desks Dying Out?
ERIC Educational Resources Information Center
Carlson, Scott
2007-01-01
This article examines how librarians are struggling to redefine, and in some cases eliminate, the venerable institution of reference desk services and it explores the new ways in which reference questions get answered at university libraries. These include fielding questions through e-mail, instant messaging, and other mobile technologies, making…
Arch-Axis Coefficient Optimization of Long-Span Deck-Type Concrete-Filled Steel Tubular Arch Bridge
NASA Astrophysics Data System (ADS)
Liu, Q. J.; Wan, S.; Liu, H. C.
2017-11-01
This paper is based on Nanpuxi super major bridge which is under construction and starts from Wencheng Zhejiang province to Taishun highway. A finite element model of the whole bridge is constructed using Midas Civil finite element software. The most adverse load combination in the specification is taken into consideration to determine the method of calculating the arch-axis coefficient of long-span deck-type concrete-filled steel tubular arch bridge. By doing this, this paper aims at providing references for similar engineering projects.
Permanent magnet flux-biased magnetic actuator with flux feedback
NASA Technical Reports Server (NTRS)
Groom, Nelson J. (Inventor)
1991-01-01
The invention is a permanent magnet flux-biased magnetic actuator with flux feedback for adjustably suspending an element on a single axis. The magnetic actuator includes a pair of opposing electromagnets and provides bi-directional forces along the single axis to the suspended element. Permanent magnets in flux feedback loops from the opposing electromagnets establish a reference permanent magnet flux-bias to linearize the force characteristics of the electromagnets to extend the linear range of the actuator without the need for continuous bias currents in the electromagnets.
Temperature dependence of broadline NMR spectra of water-soaked, epoxy-graphite composites
NASA Astrophysics Data System (ADS)
Lawing, David; Fornes, R. E.; Gilbert, R. D.; Memory, J. D.
1981-10-01
Water-soaked, epoxy resin-graphite fiber composites show a waterline in their broadline proton NMR spectrum which indicates a state of intermediate mobility between the solid and free water liquid states. The line is still present at -42 °C, but shows a reversible decrease in amplitude with decreasing temperature. The line is isotropic upon rotation of the fiber axis with respect to the external magnetic field.
NASA Technical Reports Server (NTRS)
Lewis, Carl E. (Inventor); Carlton, Lindley A. (Inventor); Saeks, Richard E. (Inventor)
2004-01-01
A control surface for an air vehicle (e.g., an aircraft, rocket, or missile) is useful for flight control at both subsonic and supersonic speeds. The control surface defines the outboardmost tip of a flight structure (e.g., a wing, tail or other stabilizer) of the air vehicle. Hence, the control surface is referred to as a `tiperon`. The tiperon has an approximately L-shaped configuration, and can be rotated relative to a fixed portion of the flight structure about a control axis. The respective surface areas of the tiperon sections forward and aft of the control axis are proportioned to place the subsonic center of pressure aft of the control axis to enhance aircraft control, and preferably also forward of the centroid of tiperon surface area. Also, the control surface sections forward and aft of the control axis are preferably mass-balanced, or at least nearly so, to enhance aircraft control at supersonic speeds. Either of the tiperon sections forward and aft of the control axis can be tapered to reduce the dependence of the moment exerted by air flow about the control axis, upon the tiperon's angle-of-attack. The tiperon also has enough surface area to control the air vehicle, even at low airspeeds. The invention is also directed to air vehicles incorporating one or more such control surfaces.
NASA Astrophysics Data System (ADS)
Tsai, Nan-Chyuan; Sue, Chung-Yang
2010-02-01
Owing to the imposed but undesired accelerations such as quadrature error and cross-axis perturbation, the micro-machined gyroscope would not be unconditionally retained at resonant mode. Once the preset resonance is not sustained, the performance of the micro-gyroscope is accordingly degraded. In this article, a direct model reference adaptive control loop which is integrated with a modified disturbance estimating observer (MDEO) is proposed to guarantee the resonant oscillations at drive mode and counterbalance the undesired disturbance mainly caused by quadrature error and cross-axis perturbation. The parameters of controller are on-line innovated by the dynamic error between the MDEO output and expected response. In addition, Lyapunov stability theory is employed to examine the stability of the closed-loop control system. Finally, the efficacy of numerical evaluation on the exerted time-varying angular rate, which is to be detected and measured by the gyroscope, is verified by intensive simulations.
Voyager Saturn encounter attitude and articulation control experience
NASA Technical Reports Server (NTRS)
Carlisle, G.; Hill, M.
1981-01-01
The Voyager attitude and articulation control system is designed for a three-axis stabilized spacecraft; it uses a biasable sun sensor and a Canopus Star Tracker (CST) for celestial control, as well as a dry inertial reference unit, comprised of three dual-axis dry gryos, for inertial control. A series of complex maneuvers was required during the first of two Voyager spacecraft encounters with Saturn (November 13, 1980); these maneuvers involved rotating the spacecraft simultaneously about two or three axes while maintaining accurate pointing of the scan platform. Titan and Saturn earth occulation experiments and a ring scattering experiment are described. Target motion compensation and the effects of celestial sensor interference are also considered. Failure of the CST, which required an extensive reevaluation of the star reference and attitude control mode strategy, is discussed. Results analyzed thus far show that the system performed with high accuracy, gathering data deeper into Saturn's atmosphere than on any previous planetary encounter.
Spatial and physical frames of reference in positioning a limb.
Garrett, S R; Pagano, C; Austin, G; Turvey, M T
1998-10-01
Splints attached to the right forearm were used to rotate the forearm's physical reference frame, as defined by the eigenvectors of its inertia tensor, relative to its spatial reference frame. In two experiments, when subjects were required to orient the forearm parallel to, or at 45 degrees to, the environmental horizontal, they produced limb orientations that were systematically deflected from the forearm's longitudinal spatial axis in the direction of the forearm's physical axes. The position sense seems to be based on inertial eigenvectors rather than on joint angles or gravitational torques.
Thompson, Donald O.; Wormley, Samuel J.
1989-03-28
A multi-viewing ultrasound transducer acquisition system for non-destructive evaluation, flaw detection and flaw reconstruction in materials. A multiple transducer assembly includes a central transducer surrounded by a plurality of perimeter transducers, each perimeter transducer having an axis of transmission which can be angularly oriented with respect to the axis of transmission of the central transducer to intersect the axis of transmission of the central transducer. A control apparatus automatically and remotely positions the transducer assembly with respect to the material by a positioning apparatus and adjusts the pe GRANT REFERENCE This invention was conceived and reduced to practice at least in part under a grant from the Department of Energy under Contract No. W-7407-ENG-82.
Uniaxial alignment of triisopropylsilylethynyl pentacene via zone-casting technique.
Su, Yajun; Gao, Xiang; Liu, Jiangang; Xing, Rubo; Han, Yanchun
2013-09-14
Uniaxially aligned triisopropylsilylethynyl pentacene (TIPS-pentacene) crystals over a large area were fabricated using zone-casting technique. The array of TIPS-pentacene displayed a high orientation degree with a dichroic ratio (DR) of 0.80. The crystals were arranged with c axis perpendicular to the substrate and the long axis of the ribbon corresponded to the a axis of TIPS-pentacene. The properties of the solutions and the processing parameters were shown to influence the formation of the oriented TIPS-pentacene crystalline array. Solvent with a low boiling point (such as chloroform) favoured the orientation of the ribbon-like crystals. The concentration of the solution should be appropriate, ensuring the crystallization velocity of TIPS-pentacene matching with the receding of the meniscus. Besides, we proved that the casting speed should be large enough to induce a sufficient concentration gradient. The orientation mechanism of TIPS-pentacene was attributed to a synergy of the ordered nuclei and a match between the crystallization velocity and the casting speed. Field effect transistors (FETs) based on the oriented TIPS-pentacene crystalline array showed a mobility of 0.67 cm(2) V(-1) s(-1).
Extreme-UV scanning wafer and reticle stages
Williams, Mark E.
2002-01-01
A stage for precise positioning of a chuck in three orthogonal linear axes and in three orthogonal rotation axes that includes first and second subassemblies. The a first subassembly includes (i) a monolithic mirror that supports the chuck wherein the monolithic mirror has at least two polished orthogonal faces for interferometric determination of the X, Y, and .THETA.z positions; (ii) a plurality of electromagnetic actuators that control fine positioning in all six axes and coarse positioning in one axis; (iii) a position sensor for measuring the vertical Z position of the monolithic mirror; and (iv) a Lorentz actuator, that includes magnet array, for effecting motion in the Y axis. The a second subassembly comprising a stepping axis beam over which the first subassembly is suspended, wherein the stepping axis beam includes a drive coil array for the Lorentz actuator. T the stage can also include a cable stage subassembly that is positioned a fixed distance away from the monolithic mirror and/or a mechanical zero reference for the first subassembly.
A Study of Airplane Maneuvers with Special Reference to Angular Velocities
NASA Technical Reports Server (NTRS)
Reid, J E
1923-01-01
This investigation was undertaken by the National Advisory Committee for Aeronautics for the purpose of increasing our knowledge on the behavior of the airplane during various maneuvers and to obtain values of the maximum angular velocities and accelerations in flight. The method consisted in flying a JN4H airplane through various maneuvers while records were being taken of the control position, the air speed, the angular velocity and the acceleration along the Z axis. The results showed that the maximum angular velocity about the X axis of radians per second in a barrel roll. The maximum angular acceleration about the X axis of -2.10 radians per (second) to the 2nd power occurred in a spin, while the maximum about the Y axis was 1.40 radians per (second) to the 2nd power when pulling suddenly out of a dive. These results have direct application to the design of airplane parts, such as propeller shaft and instruments.
The Environment Friendly Power Source for Power Supply of Mobile Communication Base Stations
NASA Astrophysics Data System (ADS)
Rudenko, N. V.; Ershov, V. V.; Evstafiev, V. V.
2017-05-01
The article describes the technical proposals to improve environmental and resource characteristics of the autonomous power supply systems of mobile communication base stations based on renewable energy sources, while ensuring the required reliability and security of power supply. These include: the replacement of diesel-generator with clean energy source - an electrochemical generator based on hydrogen fuel cells; the use of wind turbines with a vertical axis; use of specialized batteries. Based on the analysis of the know technical solutions, the structural circuit diagram of the hybrid solar-wind-hydrogen power plant and the basic principles of the algorithm of its work were proposed. The implementation of these proposals will improve the environmental and resource characteristics.
Mobile Applications as Tool for Exploiting Cultural Heritage in the Region of Turin and Milan
NASA Astrophysics Data System (ADS)
Rolando, A.; Scandiffio, A.
2013-07-01
The current research aims at showing as applications working on personal mobile communication terminals such as smartphones, can be useful for exploration of places and, at the same time, as tools able to develop interaction between cultural heritage and users. In this sense, the use of smartphone applications can be combined with GIS in order to make a platform of knowledge useful to support research studies in the field of cultural heritage, with specific reference to accessibility issues and to the combined use of integrated technologies like GPS, QR code and GIS, with the final aim to find an useful methodology for collecting data by visitors and visualizing them through mapping techniques. The research shows how the integration of different systems and technologies can be used as method for inquiring the interactions between users and cultural heritage in terms of accessibility to places. GPS devices can be used to record visitors movements (cultural routes) in terms of space and time; QR code can be used for users interaction with cultural heritage (tourists opinion, heritage ranking, facilities, accessibility); GIS software can be used for data management, analysis and mapping (tourist flows, more visited places). The focus of research is about a combination of information related to cultural routes with the information related to single cultural places. The focus of research is about a combination of information related to cultural routes with the information related to single cultural places. The current research shows the potential use of smartphone applications, as mobile device for collecting data, as means to record rides and more visited places by tourists. The research could be divided into three steps; the first one concerns with GPS that can be used to record routes; the second one deals with interaction between tourists and cultural heritage through a system based on QR code; the third one is about GIS, used as tool for management, analysis and visualization of data flows. In the current research, the field of investigation refers both to the territorial scale of Turin - Milan axis, and to the local scale of small cities localized in the territories in between. The research has been applied to Turin - Milan infrastructural axis, with the aim to represent the relationships that can be established between mobility infrastructure and cultural heritage. Such relationships should be intended in terms of accessibility from mobility infrastructure (motorway exit, service areas, railways stations) to cultural heritage localized in the surrounding landscape. The richness of cultural heritage and landscape along the chosen infrastructural bundle represent a great opportunity for territorial development in terms of attractiveness, both for local inhabitants and for tourists. Nowadays, the use of tracking technologies can be applied to investigate tourist flows, behaviors of local inhabitants in the historic city centre, number of visitors in the city and so on. In this sense it is possible to apply these technologies, which are particularly relevant in urban studies, extending them to the territorial scale of the Turin - Milan region. The large amount of available geo-referenced data can be used in different ways and it is very potential for different kind of analysis: it is possible to show tourist flows in the territory, receive information about more visited places, obtain interaction from users and cultural heritage in terms of visitors opinion about the places, give information to tourists about cultural places, monitor the accessibility to the places, understand the use of means of transport and keep under control the impacts of tourism (social, cultural, environmental) on territory. Applications based on smartphones can be considered a powerful device for visitors but also for institutions that are involved in tourism and cultural heritage management. In fact, the use of mobile applications it can produce a real time data exchange between geographical position of users and system that receives data. The research shows the opportunity to use GPS and QR code, integrated in a single smartphone application, with GIS software. In the current step of the research only the interaction with GPS and GIS has been tested on the case study of Turin - Milan. Further development of research could be realized to test the real integration of QR code with other systems, developing an application that supports QR code and GPS, and installing a barcode or other interactive devices such as NFC (Near Field Communication) on each relevant cultural places. It is evident that different actors, such as tourists, cultural heritage institutions and employers, have to be involved in this process, in order to have a deeper understanding of the problem, also integrating bottom up and top down contributions.
DOT National Transportation Integrated Search
2018-01-01
Connected vehicle mobility applications are commonly referred to as dynamic mobility applications (DMAs). DMAs seek to fully leverage frequently collected and rapidly disseminated multi-source data gathered from connected travelers, vehicles, and inf...
Direct-to-digital holography reduction of reference hologram noise and fourier space smearing
Voelkl, Edgar
2006-06-27
Systems and methods are described for reduction of reference hologram noise and reduction of Fourier space smearing, especially in the context of direct-to-digital holography (off-axis interferometry). A method of reducing reference hologram noise includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference image waves; and transforming the corresponding plurality of reference image waves into a reduced noise reference image wave. A method of reducing smearing in Fourier space includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference complex image waves; transforming the corresponding plurality of reference image waves into a reduced noise reference complex image wave; recording a hologram of an object; processing the hologram of the object into an object complex image wave; and dividing the complex image wave of the object by the reduced noise reference complex image wave to obtain a reduced smearing object complex image wave.
NASA Astrophysics Data System (ADS)
Li, Xi; Glisic, Branko
2016-04-01
By definition, the neutral axis of a loaded composite beam structure is the curve along which the section experiences zero bending strain. When no axial loading is present, the location of the neutral axis passes through the centroid of stiffness of the beam cross-section. In the presence of damage, the centroid of stiffness, as well as the neutral axis, shift from the healthy position. The concept of neutral axis can be widely applied to all beam-like structures. According to literature, a change in location of the neutral axis can be associated with damage in the corresponding cross-section. In this paper, the movement of neutral axis near locations of minute damage in a composite bridge structure was studied using finite element analysis and experimental results. The finite element model was developed based on a physical scale model of a composite simply-supported structure with controlled minute damage in the reinforced concrete deck. The structure was equipped with long-gauge fiber optic strain and temperature sensors at a healthy reference location as well as two locations of damage. A total of 12 strain sensors were installed during construction and used to monitor the structure during various loading events. This paper aims to explain previous experimental results which showed that the observed positions of neutral axis near damage locations were higher than the predicted healthy locations in some loading events. Analysis has shown that finite element analysis has potential to simulate and explain the physical behavior of the test structure.
Light field creating and imaging with different order intensity derivatives
NASA Astrophysics Data System (ADS)
Wang, Yu; Jiang, Huan
2014-10-01
Microscopic image restoration and reconstruction is a challenging topic in the image processing and computer vision, which can be widely applied to life science, biology and medicine etc. A microscopic light field creating and three dimensional (3D) reconstruction method is proposed for transparent or partially transparent microscopic samples, which is based on the Taylor expansion theorem and polynomial fitting. Firstly the image stack of the specimen is divided into several groups in an overlapping or non-overlapping way along the optical axis, and the first image of every group is regarded as reference image. Then different order intensity derivatives are calculated using all the images of every group and polynomial fitting method based on the assumption that the structure of the specimen contained by the image stack in a small range along the optical axis are possessed of smooth and linear property. Subsequently, new images located any position from which to reference image the distance is Δz along the optical axis can be generated by means of Taylor expansion theorem and the calculated different order intensity derivatives. Finally, the microscopic specimen can be reconstructed in 3D form using deconvolution technology and all the images including both the observed images and the generated images. The experimental results show the effectiveness and feasibility of our method.
Community mobilization, organizing, and media advocacy. A discussion of methodological issues.
Treno, A J; Holder, H D
1997-04-01
Community Mobilization refers to those activities that prepare communities to accept, receive, and support prevention interventions designed to reduce alcohol-involved trauma. Media advocacy refers to the strategic use of media by those seeking to advance a social or public policy initiative. Within the Community Prevention Trial, both of these activities were critical elements. This article presents the evaluation design for community mobilization and media advocacy implemented for the project. Here the authors argue for the need to include both structured and unstructured community monitoring instruments, coding of local alcohol-related news coverage, and surveying community members about the exposure to alcohol-related problems, and support for project interventions. This article also presents an audience segmentation analysis and discusses the implications of this analysis for media advocacy efforts.
Scattering and Polarization Measurements Using the PL/OPA Low Altitude Lidar
1990-12-20
66 A.3.2 Application to Lidar Data .. .. .. .. .. ... ... ... .. 70 References 72 iv List of Figures 1 The Poincare ... the vcctor in the I __ plane is the degree of linear polarization (defined as [Q2 + U2 II/2 /1). The component of the vector along the K axis is the ...scattering refers to the scattering of a monochromatic electromagr1tic plane wave by a spherically shaped, homogeneous, isotropic dielectric and conducting
Vo, Evanly; Horvatin, Matthew; Zhuang, Ziqing
2018-05-21
This study compared the performance of the following field portable aerosol instrument sets to performance of the reference Scanning Mobility Particle Sizer (SMPS): the handheld CPC-3007, the portable aerosol mobility spectrometer (PAMS), the NanoScan scanning mobility particle sizer (NanoScan SMPS) combined with an optical particle sizer (OPS). Tests were conducted with monodispersed and polydispersed aerosols. Monodispersed aerosols were controlled at the approximate concentration of 1 × 105 particles cm-3 and four monodispersed particle sizes of 30, 60, 100, and 300 nm were selected and classified for the monodispersed aerosol test, while three different steady-state concentration levels (low, medium, and high: ~8 × 103, 5 × 104, and 1 × 105 particles cm-3, respectively) were selected for the polydispersed aerosol test. For all four monodispersed aerosol sizes, particle concentrations measured with the NanoScan SMPS were within 13% of those measured with the reference SMPS. Particle concentrations measured with the PAMS were within 25% of those measured with the reference SMPS. Concentrations measured with the handheld condensation particle counter were within 30% of those measured with the reference SMPS. For the polydispersed aerosols, the particle sizes and concentrations measured with the NanoScan-OPS compared most favorably with those measured with the reference SMPS for three different concentration levels of low, medium, and high (concentration deviations ≤10% for all three concentration levels; deviations of particle size ≤4%). Although the particle-size comparability between the PAMS and the reference SMPS was quite reasonable with the deviations within 10%, the polydispersed particle concentrations measured with the PAMS were within 36% of those measured with the reference SMPS. The results of this evaluation will be useful for selecting a suitable portable device for our next workplace study phase of respiratory protection assessment. This study also provided the advantages and limitations of each individual portable instrument and therefore results from this study can be used by industrial hygienists and safety professionals, with appropriate caution, when selecting a suitable portable instrument for aerosol particle measurement in nanotechnology workplaces.
Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones
Bennett, Paul
2015-01-01
Background In recent years, there has been a great interest in analyzing upper-limb kinematics. Inertial measurement with mobile phones is a convenient and portable analysis method for studying humerus kinematics in terms of angular mobility and linear acceleration. Objective The aim of this analysis was to study upper-limb kinematics via mobile phones through six physical properties that correspond to angular mobility and acceleration in the three axes of space. Methods This cross-sectional study recruited healthy young adult subjects. Humerus kinematics was studied in 10 young adults with the iPhone4. They performed flexion and abduction analytical tasks. Mobility angle and lineal acceleration in each of its axes (yaw, pitch, and roll) were obtained with the iPhone4. This device was placed on the right half of the body of each subject, in the middle third of the humerus, slightly posterior. Descriptive statistics were calculated. Results Descriptive graphics of analytical tasks performed were obtained. The biggest range of motion was found in pitch angle, and the biggest acceleration was found in the y-axis in both analytical tasks. Focusing on tridimensional kinematics, bigger range of motion and acceleration was found in abduction (209.69 degrees and 23.31 degrees per second respectively). Also, very strong correlation was found between angular mobility and linear acceleration in abduction (r=.845) and flexion (r=.860). Conclusions The use of an iPhone for humerus tridimensional kinematics is feasible. This supports use of the mobile phone as a device to analyze upper-limb kinematics and to facilitate the evaluation of the patient. PMID:28582241
Mobile Technologies and Augmented Reality in Open Education
ERIC Educational Resources Information Center
Kurubacak, Gulsun, Ed.; Altinpulluk, Hakan, Ed.
2017-01-01
Novel trends and innovations have enhanced contemporary educational environments. When applied properly, these computing advances can create enriched learning opportunities for students. "Mobile Technologies and Augmented Reality in Open Education" is a pivotal reference source for the latest academic research on the integration of…
Huhn, Carolin; Pyell, Ute
2008-07-11
It is investigated whether those relationships derived within an optimization scheme developed previously to optimize separations in micellar electrokinetic chromatography can be used to model effective electrophoretic mobilities of analytes strongly differing in their properties (polarity and type of interaction with the pseudostationary phase). The modeling is based on two parameter sets: (i) carbon number equivalents or octanol-water partition coefficients as analyte descriptors and (ii) four coefficients describing properties of the separation electrolyte (based on retention data for a homologous series of alkyl phenyl ketones used as reference analytes). The applicability of the proposed model is validated comparing experimental and calculated effective electrophoretic mobilities. The results demonstrate that the model can effectively be used to predict effective electrophoretic mobilities of neutral analytes from the determined carbon number equivalents or from octanol-water partition coefficients provided that the solvation parameters of the analytes of interest are similar to those of the reference analytes.
Ballemans, Judith; Kempen, Gertrudis IJM; Zijlstra, GA Rixt
2011-01-01
Objective: This study aimed to provide an overview of the development, content, feasibility, and effectiveness of existing orientation and mobility training programmes in the use of the identification cane. Data sources: A systematic bibliographic database search in PubMed, PsychInfo, ERIC, CINAHL and the Cochrane Library was performed, in combination with the expert consultation (n = 42; orientation and mobility experts), and hand-searching of reference lists. Review methods: Selection criteria included a description of the development, the content, the feasibility, or the effectiveness of orientation and mobility training in the use of the identification cane. Two reviewers independently agreed on eligibility and methodological quality. A narrative/qualitative data analysis method was applied to extract data from obtained documents. Results: The sensitive database search and hand-searching of reference lists revealed 248 potentially relevant abstracts. None met the eligibility criteria. Expert consultation resulted in the inclusion of six documents in which the information presented on the orientation and mobility training in the use of the identification cane was incomplete and of low methodological quality. Conclusion: Our review of the literature showed a lack of well-described protocols and studies on orientation and mobility training in identification cane use. PMID:21795405
Thermal balance testing of the MSAT spacecraft
NASA Technical Reports Server (NTRS)
Samson, Serge; Choueiry, Elie; Pang, Kenneth
1994-01-01
This paper reports on the recently completed thermal balance/thermal vacuum testing of an MSAT satellite, the first satellite to provide mobile communications service for all of continental North America. MSAT is a two-spacecraft program, using a three-axis-stabilized HUGHES HS-601 series bus as the vehicle for the Canadian-designed payload. The thermal tests performed at the Canadian Space Agency's David Florida Laboratory in Ottawa, Canada, lasted approximately 32 days.
Comparison of Pyranometers and Reference Cells on Fixed and One-Axis Tracking Surfaces: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, Michael R; Sengupta, Manajit; Vignola, Frank
A wide variety of sensors are used to monitor the irradiance incident on solar modules to evaluate the performance of photovoltaic (PV) systems. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules, a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface,more » a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles of incidence, even though both instruments are based on measuring the short-circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded-base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer, which has a response nearly independent of the wavelength of light used by PV modules.« less
Rare cause of knee pain after martial arts demonstration: a case report.
Armstrong, Marc B; Thurber, Jalil
2013-04-01
Patellar dislocations are a commonly treated injury in the Emergency Department (ED), with a majority of cases involving lateral subluxation of the patella outside of the joint space. Intra-condylar dislocations of the patella are rare. Of the two types of axis rotation, vertical and horizontal, the vertical occurs five times less frequently. These injuries most often undergo open reduction or, at best, closed reduction under general anesthesia. To remind Emergency Physicians to consider this injury in any patient with severe knee pain and limited mobility, even with a history that is lacking significant trauma. We present a case of intra-condylar patellar dislocation with vertical axis rotation. This injury is no longer primarily attributed to the young and, barring fracture, closed reduction in the ED should be considered. Copyright © 2013 Elsevier Inc. All rights reserved.
Estébanez-de-Miguel, Elena; Fortún-Agud, María; Jimenez-Del-Barrio, Sandra; Caudevilla-Polo, Santos; Bueno-Gracia, Elena; Tricás-Moreno, José Miguel
2018-05-29
Manual therapy has been shown to increase range of motion (ROM) in hip osteoarthritis (OA). However, the optimal intensity of force during joint mobilization is not known. To compare the effectiveness of high, medium and low mobilization forces for increasing range of motion (ROM) in patients with hip OA and to analyze the effect size of the mobilization. Randomized controlled trial. Sixty patients with unilateral hip OA were randomized to three groups: low, medium or high force mobilization group. Participants received three treatment sessions of long-axis distraction mobilization (LADM) in open packed position and distraction forces were measured at each treatment. Primary outcomes: passive hip ROM assessed before and after each session. pain recorded with Western Ontario and McMaster Universities (WOMAC) pain subscale before and after the three treatment sessions. Hip ROM increased significantly (p < 0.05) in the high-force mobilization group (flexion: 10.6°, extension: 8.0°, abduction:6.4°, adduction: 3.3°, external rotation: 5.6°, internal rotation: 7.6°). These improvements in hip ROM were statistically significant (p < 0.05) compared to the low-force group. There were no significant changes in the low-force and medium-force groups for hip ROM. No significant differences in hip pain were found between treatment groups. A high force LADM in open packed position significantly increased hip ROM in all planes of motion compared to a medium or low force mobilization in patients with hip OA. A specific intensity of force mobilization appears to be necessary for increasing ROM in hip OA. Copyright © 2018 Elsevier Ltd. All rights reserved.
Open the gates: vascular neurocrine signaling mobilizes hematopoietic stem and progenitor cells.
Itkin, Tomer; Gómez-Salinero, Jesús María; Rafii, Shahin
2017-12-01
Mobilization of hematopoietic stem and progenitor cells (HSPCs) from the bone marrow (BM) into the peripheral blood is a complex process that is enhanced dramatically under stress-induced conditions. A better understanding of how the mobilization process is regulated will likely facilitate the development of improved clinical protocols for stem cell harvesting and transplantation. In this issue of the JCI, Singh et al. (1) showed that the truncated cleaved form of neurotransmitter neuropeptide Y (NPY) actively promotes a breach of BM vascular sinusoidal portals, thereby augmenting HSPC trafficking to the circulation. The authors report a previously unrecognized axis, in which expression of the enzyme dipeptidylpeptidase-4 (DPP4)/CD26 by endothelial cells activates NPY-mediated signaling by increasing the bioavailability of the truncated form of NPY. These findings underscore the importance of and urgency to develop pharmacological therapies that target the vasculature and regulate diverse aspects of hematopoiesis, such as HSPC trafficking, in steady-state and stress-induced conditions.
Wedge-Shaped GaN Nanowalls: A Potential Candidate for Two-Dimensional Electronics and Spintronics
NASA Astrophysics Data System (ADS)
Deb, Swarup; Dhar, Subhabrata
Schrödingerand Poisson equations are solved self-consistently in order to obtain the potential and charge density distribution in n-type GaN nanowalls tapered along c-axis by different angles. The study shows two-dimensional (2D) quantum confinement of electrons in the central vertical plane of the wall for the entire range of tapering. Calculation of room temperature electron mobility in the 2D channel shows a steady decrease with the increase of the inclination angle of the side facets with respect to the base. However, it is interesting to note that the mobility remains to be much larger than that of bulk GaN even for the inclination angle of 65∘. The properties of high mobility and the vertical orientation of the 2DEG plane in this system can be exploited in fabricating highly conducting transparent interconnects and field effect transistors, which can lead to large scale integration of 2D devices in future.
Frequency stabilization for mobile satellite terminals via LORAN
NASA Technical Reports Server (NTRS)
Ernst, Gregory J.; Kee, Steven M.; Marquart, Robert C.
1990-01-01
Digital satellite communication systems require careful management of frequency stability. Historically, frequency stability has been accomplished by continuously powered, high cost, high performance reference oscillators. Today's low cost mobile satellite communication equipment must operate under wide ranging environmental conditions, stabilize quickly after application of power, and provide adequate performance margin to overcome RF link impairments unique to the land mobile environment. Methods for frequency stabilization in land mobile applications must meet these objectives without incurring excessive performance degradation. A frequency stabilization scheme utilizing the LORAN (Long Range Navigation) system is presented.
1983-12-01
national gateway closest to an MCI interconnection point would be chosen.) Another significant principle is that mobile users area to be addresses the...duplication with E.16n. It was agreed that, from an addressing viewpoint, mobile subscribers are .. like fixed subscribers; i.e., mobile subscribers have TEs...reference points S and T, NTl, and may have NT2. Therefore, an ISDN number has the same ability to unambiguously identify points in mobile subscriber
The rotational elements of Mars and its satellites
NASA Astrophysics Data System (ADS)
Jacobson, R. A.; Konopliv, A. S.; Park, R. S.; Folkner, W. M.
2018-03-01
The International Astronomical Union (IAU) defines planet and satellite coordinate systems relative to their axis of rotation and the angle about that axis. The rotational elements of the bodies are the right ascension and declination of the rotation axis in the International Celestial Reference Frame and the rotation angle, W, measured easterly along the body's equator. The IAU specifies the location of the body's prime meridian by providing a value for W at epoch J2000. We provide new trigonometric series representations of the rotational elements of Mars and its satellites, Phobos and Deimos. The series for Mars are from a least squares fit to the rotation model used to orient the Martian gravity field. The series for the satellites are from a least squares fit to rotation models developed in accordance with IAU conventions from recent ephemerides.
Rotor instrumentation circuits for the Sandia 34-meter vertical axis wind turbine
NASA Astrophysics Data System (ADS)
Sutherland, Herbert J.; Stephenson, William A.
1988-07-01
Sandia National Laboratories has erected a research oriented, 34-meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas, which has been designated the Sandia 34-m VAWT Test Bed. To meet present and future research needs, the machine was equipped with a large array of sensors. This manuscript details the sensors initially placed on the rotor, their respective instrumentation circuits, and the provisions incorporated into the design of the rotor instrumentation circuits for future research. This manuscript was written as a reference manual for the rotor instrumentation of the Test Bed.
Noten, Suzie; Meeus, Mira; Stassijns, Gaetane; Van Glabbeek, Francis; Verborgt, Olivier; Struyf, Filip
2016-05-01
To systematically review the literature for efficacy of isolated articular mobilization techniques in patients with primary adhesive capsulitis (AC) of the shoulder. PubMed and Web of Science were searched for relevant studies published before November 2014. Additional references were identified by manual screening of the reference lists. All English language randomized controlled trials evaluating the efficacy of mobilization techniques on range of motion (ROM) and pain in adult patients with primary AC of the shoulder were included in this systematic review. Twelve randomized controlled trials involving 810 patients were included. Two reviewers independently screened the articles, scored methodologic quality, and extracted data for analysis. The review was conducted and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. All studies were assessed in duplicate for risk of bias using the Physiotherapy Evidence Database Scale for randomized controlled trials. The efficacy of 7 different types of mobilization techniques was evaluated. Angular mobilization (n=2), Cyriax approach (n=1), and Maitland technique (n=6) showed improvement in pain score and ROM. With respect to translational mobilizations (n=1), posterior glides are preferred to restore external rotation. Spine mobilizations combined with glenohumeral stretching and both angular and translational mobilization (n=1) had a superior effect on active ROM compared with sham ultrasound. High-intensity mobilization (n=1) showed less improvement in the Constant Murley Score than a neglect group. Finally, positive long-term effects of the Mulligan technique (n=1) were found on both pain and ROM. Overall, mobilization techniques have beneficial effects in patients with primary AC of the shoulder. Because of preliminary evidence for many mobilization techniques, the Maitland technique and combined mobilizations seem recommended at the moment. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
McKeown, Mark H.; Beason, Steven C.; Fairer, George
1992-01-01
The apparatus of the present invention provides means for obtaining accurate, dependable, measurement of bearings and directions for geologic mapping in subterranean shafts, such as, for example, nuclear waste storage investigations. In operation, a laser beam is projected along a reference bearing. A pyramid is mounted such that the laser beam is parallel to the pyramid axis and can impinge on the apex of the pyramid thus splitting the beam several ways into several beams at right angles to each other and at right angles to the reference beam. The pyramid is also translatable and rotatable in a plane perpendicular to the reference beam.
NASA Astrophysics Data System (ADS)
Meng, Fanwei; Liu, Chengying; Li, Zhijun; Wang, Liping
2013-01-01
Due to low damping ratio, flat permanent magnet linear synchronous motor's vibration is difficult to be damped and the accuracy is limited. The vibration suppressing results are not good enough in the existing research because only the longitudinal direction vibration is considered while the normal direction vibration is neglected. The parameters of the direct-axis current controller are set to be the same as those of the quadrature-axis current controller commonly. This causes contradiction between signal noise and response. To suppress the vibration, the electromagnetic force model of the flat permanent magnet synchronous linear motor is formulated first. Through the analysis of the effect that direct-axis current noise and quadrature-axis current noise have on both direction vibration, it can be declared that the conclusion that longitudinal direction vibration is only related to the quadrature-axis current noise while the normal direction vibration is related to both the quadrature-axis current noise and direct-axis current noise. Then, the simulation test on current loop with a low-pass filter is conducted and the results show that the low-pass filter can not suppress the vibration but makes the vibration more severe. So a vibration suppressing strategy that the proportional gain of direct-axis current controller adapted according to quadrature-axis reference current is proposed. This control strategy can suppress motor vibration by suppressing direct-axis current noise. The experiments results about the effect of K p and T i on normal direction vibration, longitudinal vibration and the position step response show that this strategy suppresses vibration effectively while the motor's motion performance is not affected. The maximum reduction of vibration can be up to 40%. In addition, current test under rated load condition is also conducted and the results show that the control strategy can avoid the conflict between the direct-axis current and the quadrature-axis current under typical load. Adaptive PI control strategy can effectively suppress the flat permanent magnet linear synchronous motor's vibration without affecting the motor's performance.
Four dimensional studies in earth space
NASA Technical Reports Server (NTRS)
Mather, R. S.
1972-01-01
A system of reference which is directly related to observations, is proposed for four-dimensional studies in earth space. Global control network and polar wandering are defined. The determination of variations in the earth's gravitational field with time also forms part of such a system. Techniques are outlined for the unique definition of the motion of the geocenter, and the changes in the location of the axis of rotation of an instantaneous earth model, in relation to values at some epoch of reference. The instantaneous system referred to is directly related to a fundamental equation in geodynamics. The reference system defined would provide an unambiguous frame for long period studies in earth space, provided the scale of the space were specified.
Perceptual analysis of vibrotactile flows on a mobile device.
Seo, Jongman; Choi, Seungmoon
2013-01-01
"Vibrotactile flow" refers to a continuously moving sensation of vibrotactile stimulation applied by a few actuators directly onto the skin or through a rigid medium. Research demonstrated the effectiveness of vibrotactile flow for conveying intuitive directional information on a mobile device. In this paper, we extend previous research by investigating the perceptual characteristics of vibrotactile flows rendered on a mobile device and proposing a synthesis framework for vibrotactile flows with desired perceptual properties.
Fixing the Mobility Air Forces New Way
2013-03-01
Stenner explains, “Our units and people make outstanding contributions to the national defense. Every day, we leverage a portion of the strategic...calculate the ARC’s contribution to the military’s global reach.78 The cost effectiveness that General Stenner refers to is only one of at least three...Department of the Air Force, Mobilization Planning, 18. 60 Ibid. 61 U.S. Department of the Air Force, Mobilization Planning, 9. 62 Charles E. Stenner
Q-Flex Accelerometer Thermal Performance Study
1976-09-01
change which has a significantly long time constant. This newly acquired knowledge strongly suggests elastic meterial property changes, probably due to...hinge axis reference to proof mass center of gravity and rim lands plane). In similar fashion, the Invar excitation rings serve as pickoff
A Hop-Sensitive Mechanism to Establish Route Optimization in Mobile Networks
NASA Astrophysics Data System (ADS)
Gnanaraj, J. Isac; Newton, P. Calduwel; Arockiam, L.; Kim, Tai-Hoon
The mobile network plays a vital role in mobile communications. It supports both host mobility and network mobility. The mobile network which supports network mobility can be called as NEMO. The NEMO refers to NEtwork MObility or mobile network that moves. Though NEMO provides many supports, it also suffers due to Quality of Service (QoS) issues. One such issue is Route Optimization (RO). When a Mobile Node (MN) is away from Home Network (HN), it will send a binding update to Home Agent (HA) in HN to inform its movement. If the Correspondent Node (CN) wants to send data to MN, it will send data through HA. In this scenario, three networks such as HN, Foreign Network (FN) and Correspondent Network are involved in data transfer. The involvement of these three networks affects the QoS. This paper concentrates on some of the QoS parameters to propose a QoS mechanism to establish RO among these three networks and significantly increases performance of the mobile network.
46 CFR 110.10-1 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-31; 111.105-39; 111.105-40; 113.05-7; and (2) Rules for Building and Classing Mobile Offshore... Installations of Ships and Mobile and Fixed Offshore Units—Part 1: Procedures for Calculating Short-Circuit... Park, NC 27709: (1) RP 12.6, Wiring Practices for Hazardous (Classified) Locations Instrumentation Part...
Auger, Claudine; Demers, Louise; Gélinas, Isabelle; Miller, William C; Jutai, Jeffrey W; Noreau, Luc
2010-05-01
To examine whether the impact of power mobility devices (PMDs) varies as a function of stage of usage and to explore key factors associated with greater life-space mobility for middle-aged and older adults. Multicohort study with respondents grouped as a function of stage of PMD usage (reference group with mobility impairments, n=42; initial users, 1-6mo, n=35; long-term users, 12-18mo, n=39). Cohorts were compared with respect to life-space mobility in a continuum of environments ranging from home to outside town, using analysis of variance and chi-square tests. Baseline personal, assistive device, intervention, and environmental factors associated with life-space mobility were explored with age-adjusted linear regression models. Four Canadian rehabilitation centers. Random sample of middle-aged and older adults (N=116; 50-89y) living in the community or residential care. Procurement of a powered wheelchair or scooter. Life-Space Assessment composite score. Cohort comparisons showed higher frequency of outings for PMD users in the neighborhood (P<.001) and around home (P<.05) and significantly greater Life-Space Assessment composite scores for initial and long-term users than for the reference group (P<.05). Factors such as sex, the nature of activities, and device type explained variances in Life-Space Assessment composite score ranging from 15.9% to 18.0% (P<.006). Life-space mobility increases after PMD use and remains stable across the stages of initial and long-term use. To appreciate the impact of PMDs, clinicians should consider the environment and a combination of personal and device factors that are associated with the range of life-space mobility in the first 18 months after procurement.
Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry
2008-05-01
AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Simulations were performed on tomato plants to demonstrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment.
Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry
2008-01-01
Background and Aims AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. Methods The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Key Results Simulations were performed on tomato plants to demostrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. Conclusions The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment. PMID:17766310
Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.
Kroutilķková, Daniela; Novotný, Josef; Judas, Libor
2003-02-01
The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.
Cooperative path following control of multiple nonholonomic mobile robots.
Cao, Ke-Cai; Jiang, Bin; Yue, Dong
2017-11-01
Cooperative path following control problem of multiple nonholonomic mobile robots has been considered in this paper. Based on the framework of decomposition, the cooperative path following problem has been transformed into path following problem and cooperative control problem; Then cascaded theory of non-autonomous system has been employed in the design of controllers without resorting to feedback linearization. One time-varying coordinate transformation based on dilation has been introduced to solve the uncontrollable problem of nonholonomic robots when the whole group's reference converges to stationary point. Cooperative path following controllers for nonholonomic robots have been proposed under persistent reference or reference target that converges to stationary point respectively. Simulation results using Matlab have illustrated the effectiveness of the obtained theoretical results. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Leen, J. B.; Spillane, S.; Gardner, A.; Hansen, P. C.; Gupta, M.; Baer, D. S.
2015-12-01
Natural gas leaks pose a risk to public safety both because of potential explosions as well as from the greenhouse gas potential of fugitive methane. The rapid and cost effective detection of leaks in natural gas distribution is critical to providing a system that is safe for the public and the environment. Detection of methane from a mobile platform (vehicles, aircraft, etc.) is an accepted method of identifying leaks. A robust approach to differentiating pipeline gas (thermogenic) from other biogenic sources is the detection of ethane along with methane. Ethane is present in nearly all thermogenic gas but not in biogenic sources and its presence can be used to positively identify a gas sample. We present a mobile system for the simultaneous measurement of methane and ethane that is capable of detecting pipeline leaks and differentiating pipeline gas from other biogenic sources such as landfills, swamps, sewers, and enteric fermentation. The mobile system consists of a high precision GPS, sonic anemometer, and methane/ethane analyzer based on off-axis integrated cavity output spectroscopy (OA-ICOS). In order to minimize the system cost and facilitate the wide use of mobile leak detection, the analyzer operates in the near-infrared portion of the spectrum where lasers and optics are significantly less costly than in the mid-infrared. The analyzer is capable of detecting methane with a precision of <2 ppb (1σ in 1 sec) and detecting ethane with a precision of <30 ppb (1σ in 1 sec). Additionally, measurement rates of 5 Hz allow for detection of leaks at speeds up to 50 mph. The sonic anemometer, GPS and analyzer inlet are mounted to a generic roof rack for attachment to available fleet vehicles. The system can detect leaks having a downwind concentration of as little as 10 ppb of methane above ambient, while leaks 500 ppb above ambient can be identified as thermogenic with greater than 99% certainty (for gas with 6% ethane). Finally, analysis of wind data provides an estimate of leak direction and distance. The system presented provides a robust, cost effective solution to natural gas leak detection and attribution to maximize safety and minimize greenhouse gas impacts of distribution systems.
Moritz, Sabine; Codd, Jonathan; Sellers, William I.
2017-01-01
ABSTRACT The current hypothesis regarding the mechanics of breathing in crocodylians is that the double-headed ribs, with both a capitulum and tuberculum, rotate about a constrained axis passing through the two articulations; moreover, this axis shifts in the caudal thoracic ribs, as the vertebral parapophysis moves from the centrum to the transverse process. Additionally, the ventral ribcage in crocodylians is thought to possess additional degrees of freedom through mobile intermediate ribs. In this study, X-ray reconstruction of moving morphology (XROMM) was used to quantify rib rotation during breathing in American alligators. Whilst costovertebral joint anatomy predicted overall patterns of motion across the ribcage (decreased bucket handle motion and increased calliper motion), there were significant deviations: anatomical axes overestimated pump handle motion and, generally, ribs in vivo rotate about all three body axes more equally than predicted. The intermediate ribs are mobile, with a high degree of rotation measured about the dorsal intracostal joints, especially in the more caudal ribs. Motion of the sternal ribs became increasingly complex caudally, owing to a combination of the movements of the vertebral and intermediate segments. As the crocodylian ribcage is sometimes used as a model for the ancestral archosaur, these results have important implications for how rib motion is reconstructed in fossil taxa, and illustrate the difficulties in reconstructing rib movement based on osteology alone. PMID:28855323
Absolute plate motions and true polar wander in the absence of hotspot tracks.
Steinberger, Bernhard; Torsvik, Trond H
2008-04-03
The motion of continents relative to the Earth's spin axis may be due either to rotation of the entire Earth relative to its spin axis--true polar wander--or to the motion of individual plates. In order to distinguish between these over the past 320 Myr (since the formation of the Pangaea supercontinent), we present here computations of the global average of continental motion and rotation through time in a palaeomagnetic reference frame. Two components are identified: a steady northward motion and, during certain time intervals, clockwise and anticlockwise rotations, interpreted as evidence for true polar wander. We find approximately 18 degrees anticlockwise rotation about 250-220 Myr ago and the same amount of clockwise rotation about 195-145 Myr ago. In both cases the rotation axis is located at about 10-20 degrees W, 0 degrees N, near the site that became the North American-South American-African triple junction at the break-up of Pangaea. This was followed by approximately 10 degrees clockwise rotation about 145-135 Myr ago, followed again by the same amount of anticlockwise rotation about 110-100 Myr ago, with a rotation axis in both cases approximately 25-50 degrees E in the reconstructed area of North Africa and Arabia. These rotation axes mark the maxima of the degree-two non-hydrostatic geoid during those time intervals, and the fact that the overall net rotation since 320 Myr ago is nearly zero is an indication of long-term stability of the degree-two geoid and related mantle structure. We propose a new reference frame, based on palaeomagnetism, but corrected for the true polar wander identified in this study, appropriate for relating surface to deep mantle processes from 320 Myr ago until hotspot tracks can be used (about 130 Myr ago).
Analytical drafting curves provide exact equations for plotted data
NASA Technical Reports Server (NTRS)
Stewart, R. B.
1967-01-01
Analytical drafting curves provide explicit mathematical expressions for any numerical data that appears in the form of graphical plots. The curves each have a reference coordinate axis system indicated on the curve as well as the mathematical equation from which the curve was generated.
Numerical Simulations of Lightcurves of Non-principal Axis Rotators
NASA Astrophysics Data System (ADS)
Mueller, Beatrice E. A.; Samarasinha, N. H.
2012-10-01
Theory predicts that most short-period comets should be in non-principal axis (NPA) rotational states (Jewitt 1997) due to torques caused by outgassing from the nuclei. However the fraction that is currently observed to be in such a state is small (less than 15%; Samarasinha et al 2004, and references therein). This suggests that NPA states naturally occurring as a consequence of cometary jetting are more rapidly damped because comets are structurally far weaker than has been assumed. However, there is a serious question whether this discrepancy is real or an artifact of interpreting lightcurve observations. We will present initial results of our numerical simulation of the observational manifestation of lightcurves over the range of possible NPA rotation states and determine the effects of observing geometry, signal-to-noise, and sampling. References: Jewitt, D. 1997. Cometary Rotation: An Overview. Earth, Moon, and Planets 79, 35-53. Samarasinha, N.H., B.E.A. Mueller, M.J.S. Belton,L. Jorda 2004. Rotation of Cometary Nuclei. In Comets II, pp. 281-299.
Lam, Walter Y H; Hsung, Richard T C; Choi, Winnie W S; Luk, Henry W K; Cheng, Leo Y Y; Pow, Edmond H N
2017-09-29
Accurate articulator-mounted casts are essential for occlusion analysis and for fabrication of dental prostheses. Although the axis orbital plane has been commonly used as the reference horizontal plane, some clinicians prefer to register the horizontal plane with a spirit level when the patient is in the natural head position (NHP) to avoid anatomic landmark variations. This article presents a digital workflow for registering the patient's horizontal plane in NHP on a virtual articulator. An orientation reference board is used to calibrate a stereophotogrammetry device and a 3-dimensional facial photograph with the patient in NHP. The horizontal plane can then be automatically registered to the patient's virtual model and aligned to the virtual articulator at the transverse horizontal axis level. This technique showed good repeatability with positional differences of less than 1 degree and 1 mm in 5 repeated measurements in 1 patient. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Inflight redesign of the IUE attitude control system
NASA Technical Reports Server (NTRS)
Femiano, M. D.
1986-01-01
The one- and two-gyro system designs of the International Ultraviolet Explorer (IUE) attitude control system (ACS) are examined. The inertial reference assembly that provides the primary attitude reference for IUE consists of six rate sensors which are single-axis rate integrating gyros. The gyros operate in a pulse rebalanced mode that produces an output pulse for 0.01 arcsec of motion about the input axis. The functions of the fine error sensor, fine sun sensor (FSS), the IUE reaction wheels, the onboard computer, and the hold/slew algorithm are described. The use of the hold/slew algorithm to compute the control voltage for the ACS based on the Kalman filter is studied. A two-gyro system was incorporated into IUE following gyro failure. The procedures for establishing attitude control with the two-gyro design based on the FSS is analyzed. The performance of the two-gyro system is evaluated; it is observed that the pitch and yaw gyro control is 0.24 arcsec and the control is sufficient to permit extended periods of observation.
Off-axis digital holographic camera for quantitative phase microscopy.
Monemhaghdoust, Zahra; Montfort, Frédéric; Emery, Yves; Depeursinge, Christian; Moser, Christophe
2014-06-01
We propose and experimentally demonstrate a digital holographic camera which can be attached to the camera port of a conventional microscope for obtaining digital holograms in a self-reference configuration, under short coherence illumination and in a single shot. A thick holographic grating filters the beam containing the sample information in two dimensions through diffraction. The filtered beam creates the reference arm of the interferometer. The spatial filtering method, based on the high angular selectivity of the thick grating, reduces the alignment sensitivity to angular displacements compared with pinhole based Fourier filtering. The addition of a thin holographic grating alters the coherence plane tilt introduced by the thick grating so as to create high-visibility interference over the entire field of view. The acquired full-field off-axis holograms are processed to retrieve the amplitude and phase information of the sample. The system produces phase images of cheek cells qualitatively similar to phase images extracted with a standard commercial DHM.
Attitude Heading Reference System Using MEMS Inertial Sensors with Dual-Axis Rotation
Kang, Li; Ye, Lingyun; Song, Kaichen; Zhou, Yang
2014-01-01
This paper proposes a low cost and small size attitude and heading reference system based on MEMS inertial sensors. A dual-axis rotation structure with a proper rotary scheme according to the design principles is applied in the system to compensate for the attitude and heading drift caused by the large gyroscope biases. An optimization algorithm is applied to compensate for the installation angle error between the body frame and the rotation table's frame. Simulations and experiments are carried out to evaluate the performance of the AHRS. The results show that the proper rotation could significantly reduce the attitude and heading drifts. Moreover, the new AHRS is not affected by magnetic interference. After the rotation, the attitude and heading are almost just oscillating in a range. The attitude error is about 3° and the heading error is less than 3° which are at least 5 times better than the non-rotation condition. PMID:25268911
Integrating intrinsic mobility into unmanned ground vehicle systems
NASA Astrophysics Data System (ADS)
Brosinsky, Chris A.; Penzes, Steven G.; Buehler, Martin G.; Steeves, Carl
2001-09-01
The ability of an Unmanned Ground Vehicle (UGV) to successfully move about in its environment is enabled by the synergistic combination of perception, control and platform (mobility and utility). Vast effort is being expended on the former technologies but little demonstrable evidence has been produced to indicate that the latter (mobility/utility) has been considered as an integral part of the UGV systems level capability; a concept commonly referred to as intrinsic mobility. While past work described the rationale for hybrid locomotion, this paper aims to demonstrate that integrating intrinsic mobility into a UGV systems mobility element or 'vehicle' will be a key contributor to the magnitude of autonomy that the system can achieve. This paper serves to provide compelling evidence that 1) intrinsic mobility improvements provided by hybrid locomotion configurations offer the best generic mobility, that 2) strict attention must be placed on the optimization of both utility (inherent vehicle capabilities) and mobility and that 3) the establishment of measures of performance for unmanned vehicle mobility is an unmet and latent need.
Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones.
Roldan-Jimenez, Cristina; Cuesta-Vargas, Antonio; Bennett, Paul
2015-05-20
In recent years, there has been a great interest in analyzing upper-limb kinematics. Inertial measurement with mobile phones is a convenient and portable analysis method for studying humerus kinematics in terms of angular mobility and linear acceleration. The aim of this analysis was to study upper-limb kinematics via mobile phones through six physical properties that correspond to angular mobility and acceleration in the three axes of space. This cross-sectional study recruited healthy young adult subjects. Humerus kinematics was studied in 10 young adults with the iPhone4. They performed flexion and abduction analytical tasks. Mobility angle and lineal acceleration in each of its axes (yaw, pitch, and roll) were obtained with the iPhone4. This device was placed on the right half of the body of each subject, in the middle third of the humerus, slightly posterior. Descriptive statistics were calculated. Descriptive graphics of analytical tasks performed were obtained. The biggest range of motion was found in pitch angle, and the biggest acceleration was found in the y-axis in both analytical tasks. Focusing on tridimensional kinematics, bigger range of motion and acceleration was found in abduction (209.69 degrees and 23.31 degrees per second respectively). Also, very strong correlation was found between angular mobility and linear acceleration in abduction (r=.845) and flexion (r=.860). The use of an iPhone for humerus tridimensional kinematics is feasible. This supports use of the mobile phone as a device to analyze upper-limb kinematics and to facilitate the evaluation of the patient. ©Cristina Roldan-Jimenez, Antonio Cuesta-Vargas, Paul Bennett. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 20.05.2015.
Chen, Chong; Cao, Jiang; Song, Xuguang; Zeng, Lingyu; Li, Zhenyu; Li, Yong; Xu, Kailin
2013-01-01
A high dose of granulocyte colony stimulating factor (G-CSF) is widely used to mobilize hematopoietic stem and progenitor cells (HSPC), but G-CSF is relatively inefficient and may cause adverse effects. Recently, adrenaline has been found to play important roles in HSPC mobilization. In this study, we explored whether adrenaline combined with G-CSF could induce HSPC mobilization in a mouse model. Mice were treated with adrenaline and either a high or low dose of G-CSF alone or in combination. Peripheral blood HSPC counts were evaluated by flow cytometry. Levels of bone marrow SDF-1 were measured by ELISA, the transcription of CXCR4 and SDF-1 was measured by real-time RT-PCR, and CXCR4 protein was detected by Western blot. Our results showed that adrenaline alone fails to mobilize HSPCs into the peripheral blood; however, when G-CSF and adrenaline are combined, the WBC counts and percentages of HSPCs are significantly higher compared to those in mice that received G-CSF alone. The combined use of adrenaline and G-CSF not only accelerated HSPC mobilization, but also enabled the efficient mobilization of HSPCs into the peripheral blood at lower doses of G-CSF. Adrenaline/G-CSF treatment also extensively downregulated levels of SDF-1 and CXCR4 in mouse bone marrow. These results demonstrated that adrenaline combined with G-CSF can induce HSPC mobilization by down-regulating the CXCR4/SDF-1 axis, indicating that the use of adrenaline may enable the use of reduced dosages or durations of G-CSF treatment, minimizing G-CSF-associated complications.
Enhancing emergency care in low-income countries using mobile technology-based training tools
Edgcombe, Hilary; Paton, Chris; English, Mike
2016-01-01
In this paper, we discuss the role of mobile technology in developing training tools for health workers, with particular reference to low-income countries (LICs). The global and technological context is outlined, followed by a summary of approaches to using and evaluating mobile technology for learning in healthcare. Finally, recommendations are made for those developing and using such tools, based on current literature and the authors' involvement in the field. PMID:27658948
Fleming, R.W.; Ellen, S.D.; Algus, M.A.
1989-01-01
The severe rainstorm of January 3, 4 and 5, 1982, in the San Francisco Bay area, California, produced numerous landslides, many of which transformed into damaging debris flows. The process of transformation was studied in detail at one site where only part of a landslide mobilized into several episodes of debris flow. The focus of our investigation was to learn whether the landslide debris dilated or contracted during the transformation from slide to flow. The landslide debris consisted of sandy colluvium that was separable into three soil horizons that occupied the axis of a small topographic swale. Failure involved the entire thickness of colluvium; however, over parts of the landslide, the soil A-horizon failed separately from the remainder of the colluvium. Undisturbed samples were taken for density measurements from outside the landslide, from the failure zone and overlying material from the part of the landslide that did not mobilize into debris flows, and from the debris-flow deposits. The soil A-horizon was contractive and mobilized to flows in a process analogous to liquefaction of loose, granular soils during earthquakes. The soil B- and C-horizons were dilative and underwent 2 to 5% volumetric expansion during landslide movement that permitted mobilization of debris-flow episodes. Several criteria can be used in the field to differentiate between contractive and dilative behavior including lag time between landsliding and mobilization of flow, episodic mobilization of flows, and partial or complete transformation of the landslide. ?? 1989.
Off-axis impact of unidirectional composites with cracks: Dynamic stress intensification
NASA Technical Reports Server (NTRS)
Sih, G. C.; Chen, E. P.
1979-01-01
The dynamic response of unidirectional composites under off axis (angle loading) impact is analyzed by assuming that the composite contains an initial flaw in the matrix material. The analytical method utilizes Fourier transform for the space variable and Laplace transform for the time variable. The off axis impact is separated into two parts, one being symmetric and the other skew-symmetric with reference to the crack plane. Transient boundary conditions of normal and shear tractions are applied to a crack embedded in the matrix of the unidirectional composite. The two boundary conditions are solved independently and the results superimposed. Mathematically, these conditions reduce the problem to a system of dual integral equations which are solved in the Laplace transform plane for the transformation of the dynamic stress intensity factor. The time inversion is carried out numerically for various combinations of the material properties of the composite and the results are displayed graphically.
Three-axis attitude determination via Kalman filtering of magnetometer data
NASA Technical Reports Server (NTRS)
Martel, Francois; Pal, Parimal K.; Psiaki, Mark L.
1988-01-01
A three-axis Magnetometer/Kalman Filter attitude determination system for a spacecraft in low-altitude Earth orbit is developed, analyzed, and simulation tested. The motivation for developing this system is to achieve light weight and low cost for an attitude determination system. The extended Kalman filter estimates the attitude, attitude rates, and constant disturbance torques. Accuracy near that of the International Geomagnetic Reference Field model is achieved. Covariance computation and simulation testing demonstrate the filter's accuracy. One test case, a gravity-gradient stabilized spacecraft with a pitch momentum wheel and a magnetically-anchored damper, is a real satellite on which this attitude determination system will be used. The application to a nadir pointing satellite and the estimation of disturbance torques represent the significant extensions contributed by this paper. Beyond its usefulness purely for attitude determination, this system could be used as part of a low-cost three-axis attitude stabilization system.
Science observations with the IUE using the one-gyro mode
NASA Technical Reports Server (NTRS)
Imhoff, C.; Pitts, R.; Arquilla, R.; Shrader, Chris R.; Perez, M. R.; Webb, J.
1990-01-01
The International Ultraviolet Explorer (IUE) attitude control system originally included an inertial reference package containing six gyroscopes for three axis stabilization. The science instrument includes a prime and redundant Field Error Sensor (FES) camera for target acquisition and offset guiding. Since launch, four of the six gyroscopes have failed. The current attitude control system utilizes the remaining two gyros and a Fine Sun Sensor (FSS) for three axis stabilization. When the next gyro fails, a new attitude control system will be uplinked which will rely on the remaining gyro and the FSS for general three axis stabilization. In addition to the FSS, the FES cameras will be required to assist in maintaining fine attitude control during target acquisition. This has required thoroughly determining the characteristics of the FES cameras and the spectrograph aperture plate as well as devising new target acquisition procedures. The results of this work are presented.
Science observations with the IUE using the one-gyro mode
NASA Technical Reports Server (NTRS)
Imhoff, C.; Pitts, R.; Arquilla, R.; Shrader, C.; Perez, M.; Webb, J.
1990-01-01
The International Ultraviolet Explorer (IUE) attitude control system originally included an inertial reference package containing six gyroscopes for three axis stabilization. The science instrument includes a prime and redundant Field Error Sensor (FES) camera for target acquisition and offset guiding. Since launch, four of the six gyroscopes have failed. The current attitude control system utilizes the remaining two gyros and a Fine Sun Sensor (FSS) for three axis stabilization. When the next gyro fails, a new attitude control system will be uplinked, which will relay on the remaining gyro and the FSS for general three axis stabilization. In addition to the FSS, the FES cameras will be required to assist in maintaining fine attitude control during target acquisition. This has required thoroughly determining the characteristics of the FES cameras and the spectrograph aperture plate as well as devising new target acquisition procedures. The results of this work are presented.
Parallel-quadrature phase-shifting digital holographic microscopy using polarization beam splitter
Das, Bhargab; Yelleswarapu, Chandra S; Rao, DVGLN
2012-01-01
We present a digital holography microscopy technique based on parallel-quadrature phase-shifting method. Two π/2 phase-shifted holograms are recorded simultaneously using polarization phase-shifting principle, slightly off-axis recording geometry, and two identical CCD sensors. The parallel phase-shifting is realized by combining circularly polarized object beam with a 45° degree polarized reference beam through a polarizing beam splitter. DC term is eliminated by subtracting the two holograms from each other and the object information is reconstructed after selecting the frequency spectrum of the real image. Both amplitude and phase object reconstruction results are presented. Simultaneous recording eliminates phase errors caused by mechanical vibrations and air turbulences. The slightly off-axis recording geometry with phase-shifting allows a much larger dimension of the spatial filter for reconstruction of the object information. This leads to better reconstruction capability than traditional off-axis holography. PMID:23109732
Blum, Werner F; Alherbish, Abdullah; Alsagheir, Afaf; El Awwa, Ahmed; Kaplan, Walid; Koledova, Ekaterina; Savage, Martin O
2018-01-01
The growth hormone (GH)–insulin-like growth factor (IGF)-I axis is a key endocrine mechanism regulating linear growth in children. While paediatricians have a good knowledge of GH secretion and assessment, understanding and use of measurements of the components of the IGF system are less current in clinical practice. The physiological function of this axis is to increase the anabolic cellular processes of protein synthesis and mitosis, and reduction of apoptosis, with each being regulated in the appropriate target tissue. Measurement of serum IGF-I and IGF-binding protein (IGFBP)-3 concentrations can complement assessment of GH status in the investigation of short stature and contribute to prediction of growth response during GH therapy. IGF-I monitoring during GH therapy also informs the clinician about adherence and provides a safety reference to avoid over-dosing during long-term management. PMID:29724795
Determination of the accuracy and operating constants in a digitally biased ring core magnetometer
Green, A.W.
1990-01-01
By using a very stable voltage reference and a high precision digital-to-analog converter to set bias in digital increments, the inherently high stability and accuracy of a ring core magnetometer can be significantly enhanced. In this case it becomes possible to measure not only variations about the bias level, but to measure the entire value of the field along each magnetometer sensing axis in a nearly absolute sense. To accomplish this, one must accurately determine the value of the digital bias increment for each axis, the zero field offset value for each axis, the scale values, and the transfer coefficients (or nonorthogonality angles) for pairs of axes. This determination can be carried out very simply, using only the Earth's field, a proton magnetometer, and a tripod-mounted fixture which is capable of rotations about two axes that are mutually perpendicular to the Earth's magnetic field vector. ?? 1990.
NASA Astrophysics Data System (ADS)
Lee, Dukhyung; Kim, Dai-Sik
2016-01-01
We study light scattering off rectangular slot nano antennas on a metal film varying incident polarization and incident angle, to examine which field vector of light is more important: electric vector perpendicular to, versus magnetic vector parallel to the long axis of the rectangle. While vector Babinet’s principle would prefer magnetic field along the long axis for optimizing slot antenna function, convention and intuition most often refer to the electric field perpendicular to it. Here, we demonstrate experimentally that in accordance with vector Babinet’s principle, the incident magnetic vector parallel to the long axis is the dominant component, with the perpendicular incident electric field making a small contribution of the factor of 1/|ε|, the reciprocal of the absolute value of the dielectric constant of the metal, owing to the non-perfectness of metals at optical frequencies.
Blum, Werner; Alherbish, Abdullah; Alsagheir, Afaf; El Awwa, Ahmed; Kaplan, Walid; Koledova, Ekaterina; Savage, Martin O
2018-05-03
The growth hormone (GH)-insulin-like growth factor (IGF)-I axis is a key endocrine mechanism regulating linear growth in children. While paediatricians have a good knowledge of GH secretion and assessment, understanding and use of measurements of the components of the IGF system are less current in clinical practice. The physiological function of this axis is to increase the anabolic cellular processes of protein synthesis and mitosis, and reduction of apoptosis, with each being regulated in the appropriate target tissue. Measurement of serum IGF-I and IGFBP-3 concentrations can complement assessment of GH status in the investigation of short stature and contribute to prediction of growth response during GH therapy. IGF-I monitoring during GH therapy also informs the clinician about adherence and provides a safety reference to avoid over-dosing during long-term management.
Yagai, Shiki; Seki, Tomohiro; Murayama, Haruno; Wakikawa, Yusuke; Ikoma, Tadaaki; Kikkawa, Yoshihiro; Karatsu, Takashi; Kitamura, Akihide; Honsho, Yoshihito; Seki, Shu
2010-12-06
Extremely long nanofibers, whose lengths reach the millimeter regime, are generated via co-aggregation of a melamine-appended perylene bisimide semiconductor and a substituted cyanurate, both of which are ditopic triple-hydrogen-bonding building blocks; they co-aggregate in an unexpected stoichiometrically mismatched 1:2 ratio. Various microscopic and X-ray diffraction studies suggest that hydrogen-bonded polymeric chains are formed along the long axis of the nanofibers by the 1:2 complexation of the two components, which further stack along the short axis of the nanofibers. The photocarrier generation mechanism in the nanofibers is investigated by time-of-flight (TOF) experiments under electric and magnetic fields, revealing the birth and efficient recombination of singlet geminate electron-hole pairs. Flash-photolysis time-resolved microwave conductivity (FP-TRMC) measurements revealed intrinsic 1D electron mobilities up to 0.6 cm(2) V(-1) s(-1) within nanofibers.
Mechanical responses of a-axis GaN nanowires under axial loads
NASA Astrophysics Data System (ADS)
Wang, R. J.; Wang, C. Y.; Feng, Y. T.; Tang, Chun
2018-03-01
Gallium nitride (GaN) nanowires (NWs) hold technological significance as functional components in emergent nano-piezotronics. However, the examination of their mechanical responses, especially the mechanistic understanding of behavior beyond elasticity (at failure) remains limited due to the constraints of in situ experimentation. We therefore performed simulations of the molecular dynamics (MD) of the mechanical behavior of [1\\bar{2}10]-oriented GaN NWs subjected to tension or compression loading until failure. The mechanical properties and critical deformation processes are characterized in relation to NW sizes and loading conditions. Detailed examinations revealed that the failure mechanisms are size-dependent and controlled by the dislocation mobility on shuffle-set pyramidal planes. The size dependence of the elastic behavior is also examined in terms of the surface structure determined modification of Young’s modulus. In addition, a comparison with c-axis NWs is made to show how size-effect trends vary with the growth orientation of NWs.
Light-Directed Ranging System Implementing Single Camera System for Telerobotics Applications
NASA Technical Reports Server (NTRS)
Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)
1997-01-01
A laser-directed ranging system has utility for use in various fields, such as telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a single video camera and a directional light source such as a laser mounted on a camera platform, and a remotely positioned operator. In one embodiment, the position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. The laser is offset vertically and horizontally from the camera, and the laser/camera platform is directed by the user to point the laser and the camera toward a target device. The image produced by the video camera is processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. A reference point is defined at a point in the video frame, which may be located outside of the image area of the camera. The disparity between the digital image of the laser spot and the reference point is calculated for use in a ranging analysis to determine range to the target.
1947-04-01
EXPERS5EHTAL RESULTS By G-arry C. Myers, Jr. STHMÄRY Hi order to provide " basic data on helicopter rotor-"blade motion, photographic .records of...ABOUT 2HE AXIS OF NO FEATHERING Reason for conversion.- At the time that the " basic theoretical treatments, such as that of reference 1, were made...of the machanical means used for achieving it. This fact may be confirmed by inspection but has also been demonstrated mathematically in reference
Obsessive-compulsive personality disorder and behavioral disinhibition.
Villemarette-Pittman, Nicole R; Stanford, Matthew S; Greve, Kevin W; Houston, Rebecca J; Mathias, Charles W
2004-01-01
Although obsessive-compulsive personality disorder (OCPD) is an Axis II diagnosis that is not commonly associated with behavioral disinhibition, the literature contains reports of occasional explosive aggressive outbursts. Existing explanations of OCPD etiology do not address the coexistence of compulsive and impulsive features witnessed in some subpopulations of patients. In this study, the authors present a compensatory theory of OCPD in an effort to explain clinical observations of an unexpectedly large number of OCPD diagnoses among patients clinic referred and self-referred for aggression problems.
Place affinities, lifestyle mobilities and quality-of-life
Daniel R. Williams; Norman McIntyre
2012-01-01
Tourism is a spatial practice involving two seemingly opposing geographic processes. One is aptly captured by McHugh's (2006b) phrase "nomads of desire" referring to the ways amenity-seeking mobilities and travel are deeply rooted in the Western imagination. The other is succinctly expressed in Lippard's (1997) book titled "The Lure of the...
46 CFR 110.10-1 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; 111.105-40; 113.05-7; and (2) Rules for Building and Classing Mobile Offshore Drilling Units, Part 4...-1; (31) IEC 61363-1 Electrical Installations of Ships and Mobile and Fixed Offshore Units—Part 1.... Box 12277, Research Triangle Park, NC 27709: (1) RP 12.6, Wiring Practices for Hazardous (Classified...
Create a Sense of Place for the Mobile Learner
ERIC Educational Resources Information Center
Hemmig, William; Johnstone, Brian T.; Montet, Margaret
2012-01-01
"Sense of place" no longer applies only to the physical library. All students are distance learners to one extent or another, and all distance services must be considered as a single virtual learning commons. Librarians at Bucks County (PA) Community College implement and integrate current teaching, learning, virtual reference, and mobile access…
Identity as Immunology: History Teaching in Two Ethnonational Borders of Europe
ERIC Educational Resources Information Center
Klerides, Eleftherios; Zembylas, Michalinos
2017-01-01
The power of local borders to resist and prevent transnational mobilities in education has received little attention in comparative education. In this article we explore the motif of "border immunology' with reference to new history, a mobile paradigm of history teaching, and Greek-Cypriot and Turkish-Cypriot history textbooks as types of…
Mobile, Collaborative Situated Knowledge Creation for Urban Planning
Zurita, Gustavo; Baloian, Nelson
2012-01-01
Geo-collaboration is an emerging research area in computer sciences studying the way spatial, geographically referenced information and communication technologies can support collaborative activities. Scenarios in which information associated to its physical location are of paramount importance are often referred as Situated Knowledge Creation scenarios. To date there are few computer systems supporting knowledge creation that explicitly incorporate physical context as part of the knowledge being managed in mobile face-to-face scenarios. This work presents a collaborative software application supporting visually-geo-referenced knowledge creation in mobile working scenarios while the users are interacting face-to-face. The system allows to manage data information associated to specific physical locations for knowledge creation processes in the field, such as urban planning, identifying specific physical locations, territorial management, etc.; using Tablet-PCs and GPS in order to geo-reference data and information. It presents a model for developing mobile applications supporting situated knowledge creation in the field, introducing the requirements for such an application and the functionalities it should have in order to fulfill them. The paper also presents the results of utility and usability evaluations. PMID:22778639
Mobile, collaborative situated knowledge creation for urban planning.
Zurita, Gustavo; Baloian, Nelson
2012-01-01
Geo-collaboration is an emerging research area in computer sciences studying the way spatial, geographically referenced information and communication technologies can support collaborative activities. Scenarios in which information associated to its physical location are of paramount importance are often referred as Situated Knowledge Creation scenarios. To date there are few computer systems supporting knowledge creation that explicitly incorporate physical context as part of the knowledge being managed in mobile face-to-face scenarios. This work presents a collaborative software application supporting visually-geo-referenced knowledge creation in mobile working scenarios while the users are interacting face-to-face. The system allows to manage data information associated to specific physical locations for knowledge creation processes in the field, such as urban planning, identifying specific physical locations, territorial management, etc.; using Tablet-PCs and GPS in order to geo-reference data and information. It presents a model for developing mobile applications supporting situated knowledge creation in the field, introducing the requirements for such an application and the functionalities it should have in order to fulfill them. The paper also presents the results of utility and usability evaluations.
NASA Astrophysics Data System (ADS)
Wiedensohler, A.; Birmili, W.; Nowak, A.; Sonntag, A.; Weinhold, K.; Merkel, M.; Wehner, B.; Tuch, T.; Pfeifer, S.; Fiebig, M.; Fjäraa, A. M.; Asmi, E.; Sellegri, K.; Depuy, R.; Venzac, H.; Villani, P.; Laj, P.; Aalto, P.; Ogren, J. A.; Swietlicki, E.; Williams, P.; Roldin, P.; Quincey, P.; Hüglin, C.; Fierz-Schmidhauser, R.; Gysel, M.; Weingartner, E.; Riccobono, F.; Santos, S.; Grüning, C.; Faloon, K.; Beddows, D.; Harrison, R.; Monahan, C.; Jennings, S. G.; O'Dowd, C. D.; Marinoni, A.; Horn, H.-G.; Keck, L.; Jiang, J.; Scheckman, J.; McMurry, P. H.; Deng, Z.; Zhao, C. S.; Moerman, M.; Henzing, B.; de Leeuw, G.; Löschau, G.; Bastian, S.
2012-03-01
Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers) or SMPS (Scanning Mobility Particle Sizers) have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer. We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data. Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research) and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the peak particle number concentration when all settings were done carefully. The consistency of these reference instruments to the total particle number concentration was demonstrated to be less than 5%. Additionally, a new data structure for particle number size distributions was introduced to store and disseminate the data at EMEP (European Monitoring and Evaluation Program). This structure contains three levels: raw data, processed data, and final particle size distributions. Importantly, we recommend reporting raw measurements including all relevant instrument parameters as well as a complete documentation on all data transformation and correction steps. These technical and data structure standards aim to enhance the quality of long-term size distribution measurements, their comparability between different networks and sites, and their transparency and traceability back to raw data.
WebGIS based community services architecture by griddization managements and crowdsourcing services
NASA Astrophysics Data System (ADS)
Wang, Haiyin; Wan, Jianhua; Zeng, Zhe; Zhou, Shengchuan
2016-11-01
Along with the fast economic development of cities, rapid urbanization, population surge, in China, the social community service mechanisms need to be rationalized and the policy standards need to be unified, which results in various types of conflicts and challenges for community services of government. Based on the WebGIS technology, the article provides a community service architecture by gridding management and crowdsourcing service. The WEBGIS service architecture includes two parts: the cloud part and the mobile part. The cloud part refers to community service centres, which can instantaneously response the emergency, visualize the scene of the emergency, and analyse the data from the emergency. The mobile part refers to the mobile terminal, which can call the centre, report the event, collect data and verify the feedback. This WebGIS based community service systems for Huangdao District of Qingdao, were awarded the “2015’ national innovation of social governance case of typical cases”.
Psychopathology in Women Arrested for Domestic Violence
ERIC Educational Resources Information Center
Stuart, Gregory L.; Moore, Todd M.; Gordon, Kristina Coop; Ramsey, Susan E.; Kahler, Christopher W.
2006-01-01
This study examined the prevalence of psychopathology among women arrested for violence and whether the experience of intimate partner violence (IPV) was associated with Axis I psychopathology. Women who were arrested for domestic violence perpetration and court referred to violence intervention programs (N=103) completed measures of IPV…
Determination of Flux-Gate Magnetometer Spin Axis Offsets with the Electron Drift Instrument
NASA Astrophysics Data System (ADS)
Plaschke, Ferdinand; Nakamura, Rumi; Giner, Lukas; Teubenbacher, Robert; Chutter, Mark; Leinweber, Hannes K.; Magnes, Werner
2014-05-01
Spin-stabilization of spacecraft enormously supports the in-flight calibration of onboard flux-gate magnetometers (FGMs): eight out of twelve calibration parameters can be determined by minimization of spin tone and harmonics in the calibrated magnetic field measurements. From the remaining four parameters, the spin axis offset is usually obtained by analyzing observations of Alfvénic fluctuations in the solar wind. If solar wind measurements are unavailable, other methods for spin axis offset determination need to be used. We present two alternative methods that are based on the comparison of FGM and electron drift instrument (EDI) data: (1) EDI measures the gyration periods of instrument-emitted electrons in the ambient magnetic field. They are inversely proportional to the magnetic field strength. Differences between FGM and EDI measured field strengths can be attributed to inaccuracies in spin axis offset, if the other calibration parameters are accurately known. (2) For EDI electrons to return to the spacecraft, they have to be sent out in perpendicular direction to the ambient magnetic field. Minimization of the variance of electron beam directions with respect to the FGM-determined magnetic field direction also yields an estimate of the spin axis offset. Prior to spin axis offset determination, systematic inaccuracies in EDI gyration period measurements and in the transformation of EDI beam directions into the FGM spin-aligned reference coordinate system have to be corrected. We show how this can be done by FGM/EDI data comparison, as well.
Analysis of off-axis holographic system based on improved Jamin interferometer
NASA Astrophysics Data System (ADS)
Li, Baosheng; Dong, Hang; Chen, Lijuan; Zhong, Qi
2018-02-01
In this paper, an improved Interferometer was introduced which based on traditional Jamin Interferometer to solve the twin image where appear in on-axis holographic. Adjust the angle of reference light and object light that projected onto the CCD by change the reflector of the system to separate the zero order of diffraction, the virtual image and the real image, so that could eliminate the influence of the twin image. The result of analysis shows that the system could be realized in theory. After actually building the system, the hologram of the calibration plate is reconstructed and the result is shown to be feasible.
Distributed Combinatorial Optimization Using Privacy on Mobile Phones
NASA Astrophysics Data System (ADS)
Ono, Satoshi; Katayama, Kimihiro; Nakayama, Shigeru
This paper proposes a method for distributed combinatorial optimization which uses mobile phones as computers. In the proposed method, an ordinary computer generates solution candidates and mobile phones evaluates them by referring privacy — private information and preferences. Users therefore does not have to send their privacy to any other computers and does not have to refrain from inputting their preferences. They therefore can obtain satisfactory solution. Experimental results have showed the proposed method solved room assignment problems without sending users' privacy to a server.
Antony, Bhavna J; Stetson, Paul F; Abramoff, Michael D; Lee, Kyungmoo; Colijn, Johanna M; Buitendijk, Gabriëlle H S; Klaver, Caroline C W; Roorda, Austin; Lujan, Brandon J
2015-07-01
Off-axis acquisition of spectral domain optical coherence tomography (SDOCT) images has been shown to increase total retinal thickness (TRT) measurements. We analyzed the reproducibility of TRT measurements obtained using either the retinal pigment epithelium (RPE) or Bruch's membrane as reference surfaces in off-axis scans intentionally acquired through multiple pupil positions. Five volumetric SDOCT scans of the macula were obtained from one eye of 25 normal subjects. One scan was acquired through a central pupil position, while subsequent scans were acquired through four peripheral pupil positions. The internal limiting membrane, the RPE, and Bruch's membrane were segmented using automated approaches. These volumes were registered to each other and the TRT was evaluated in 9 Early Treatment of Diabetic Retinopathy Study (ETDRS) regions. The reproducibility of the TRT obtained using the RPE was computed using the mean difference, coefficient of variation (CV), and the intraclass correlation coefficient (ICC), and compared to those obtained using Bruch's membrane as the reference surface. A secondary set of 1545 SDOCT scans was also analyzed in order to gauge the incidence of off-axis scans in a typical acquisition environment. The photoreceptor tips were dimmer in off-axis images, which affected the RPE segmentation. The overall mean TRT difference and CV obtained using the RPE were 7.04 ± 4.31 μm and 1.46%, respectively, whereas Bruch's membrane was 1.16 ± 1.00 μm and 0.32%, respectively. The ICCs at the subfoveal TRT were 0.982 and 0.999, respectively. Forty-one percent of the scans in the secondary set showed large tilts (> 6%). RPE segmentation is confounded by its proximity to the interdigitation zone, a structure strongly affected by the optical Stiles-Crawford effect. Bruch's membrane, however, is unaffected leading to a more robust segmentation that is less dependent upon pupil position. The way in which OCT images are acquired can independently affect the accuracy of automated retinal thickness measurements. Assessment of scan angle in a clinical dataset demonstrates that off-axis scans are common, which emphasizes the need for caution when relying on automated thickness parameters when this component of scan acquisition is not controlled for.
Thomas, Silke; Kühnlein, Anja; Heinrich, Sabine; Praml, Georg; Nowak, Dennis; von Kries, Rüdiger; Radon, Katja
2008-09-01
The use of mobile phone telecommunication has increased in recent years. In parallel, there is growing concern about possible adverse health effects of cellular phone networks. We used personal dosimetry to investigate the association between exposure to mobile phone frequencies and well-being in adults. A random population-based sample of 329 adults living in four different Bavarian towns was assembled for the study. Using a dosimeter (ESM-140 Maschek Electronics), we obtained an exposure profile over 24 h for three mobile phone frequency ranges (measurement interval 1 s, limit of determination 0.05 V/m). Exposure levels over waking hours were totalled and expressed as mean percentage of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level. Each participant reported acute symptoms in a day-long diary. Data on five groups of chronic symptoms and potential confounders were assessed during an interview. The overall exposure to high-frequency electromagnetic fields was markedly below the ICNIRP reference level. We did not find any statistically significant association between the exposure and chronic symptoms or between the exposure and acute symptoms. Larger studies using mobile phone dosimetry are warranted to confirm these findings. Copyright 2008 Wiley-Liss, Inc.
Prolonged mechanical ventilation in Canadian intensive care units: a national survey.
Rose, Louise; Fowler, Robert A; Fan, Eddy; Fraser, Ian; Leasa, David; Mawdsley, Cathy; Pedersen, Cheryl; Rubenfeld, Gordon
2015-02-01
We sought to describe prevalence and care practices for patients experiencing prolonged mechanical ventilation (PMV), defined as ventilation for 21 or more consecutive days and medical stability. We provided the survey to eligible units via secure Web link to a nominated unit champion from April to November 2012. Weekly telephone and e-mail reminders were sent for 6 weeks. Response rate was 215 (90%) of 238 units identifying 308 patients requiring PMV on the survey day occupying 11% of all Canadian ventilator-capable beds. Most units (81%) used individualized plans for both weaning and mobilization. Weaning and mobilization protocols were available in 48% and 38% of units, respectively. Of those units with protocols, only 25% reported weaning guidance specific to PMV, and 11% reported mobilization content for PMV. Only 30% of units used specialized mobility equipment. Most units referred to speech language pathologists (88%); use of communication technology was infrequent (11%). Only 29% routinely referred to psychiatry/psychology, and 17% had formal discharge follow-up services. Prolonged mechanical ventilation patients occupied 11% of Canadian acute care ventilator bed capacity. Most units preferred an individualized approach to weaning and mobilization with considerable variation in weaning methods, protocol availability, access to specialized rehabilitation equipment, communication technology, psychiatry, and discharge follow-up. Copyright © 2014 Elsevier Inc. All rights reserved.
Web and Mobile Based HIV Prevention and Intervention Programs Pros and Cons - A Review.
Niakan, Sharareh; Mehraeen, Esmaeil; Noori, Tayebeh; Gozali, Elahe
2017-01-01
With the increasing growth of HIV positive people the use of information and communication technologies (ICT) can play an important role in controlling the spread of the AIDS. Web and Mobile are the new technologies that young people take advantage from them. In this study a review to investigate the web and mobile based HIV prevention and intervention programs was carried out. A scoping review was conducted including PubMed, Science direct, Web of Science and Proquest to find relevant sources that published in 2009 to 2016. To identify published, original research that reported the web and mobile-based HIV prevention and intervention programs, an organized search was conducted with the following search keywords in combination: HIV, AIDS, m-Health, Mobile phone, Cell phone, Smartphone, Mobile health, internet, and web. Using the employed strategies, 173 references retrieved. Searched articles were compared based on their titles and abstracts. To identify duplicated articles, the title and abstracts were considered and 101 duplicated references were excluded. By going through the full text of related papers, 35 articles were found to be more related to the questions of this paper from which 72 final included. The advantages of web and mobile-based interventions include the possibility to provide constancy in the delivery of an intervention, impending low cost, and the ability to spread the intervention to an extensive community. Online programs such as Chat room-based Education program, Web-based therapeutic education system, and Online seek information can use for HIV/AIDS prevention. To use of mobile for HIV/AIDS prevention and intervention, programs including in: Health system focused applications, Population health focused applications, and Health messaging can be used.
Operating System Support for Mobile Interactive Applications
2002-08-01
Buckingham Palace (inte- rior) Scene Number of polygons Taj Mahal 127406 Café 138598 Notre Dame 160206 Buckingham Palace 235572...d em an d (m ill io ns o f c yc le s) ª Number of polygons rendered Taj Mahal Café Notre Dame Buckingham Palace (a) Random camera position 0 100 200...Notre Dame Buckingham Palace (b) Fixed camera position The « -axis is the number of polygons rendered, i.e. ¬G where ¬ is the original model size
Interaction Between the Celestial and the Terrestrial Reference Frames
NASA Technical Reports Server (NTRS)
Gordon, David; MacMillan, Dan; Bolotin, Sergei; Le Bail, Karine; Gipson, John; Ma, Chopo
2010-01-01
Effects of International Celestial Reference Frame (ICRF2) on the Terrestrial Reference Frames (TRF), CRF and EOP's, The ICRF2 became official on Jan. 1, 2010. It includes positions of 3414 compact radio astronomical sources observed with VLBI, a fivefold increase from the first ICRF. Numerous new VLBI models were used and the most unstable sources were treated as arc parameters to avoid distortions of the frame. The ICRF2 has a noise floor of 40 micro-arc-seconds and an axis stability of 10 micro-arc-seconds. It was aligned with the ICRS using 138 stable sources common to ICRF2 and ICRF-Ext2. Maintenance of ICRF2 is to be made using 295 defining sources chosen for their historical positional stability, minimal source structure, and sky distribution. Their stability and their more uniform sky distribution eliminate the two largest weaknesses of ICRF I. The switchover to ICRF2 has some small effects on the TRF, CRF and Earth Orientation Parameters (EOP). A CRF based on ICRF2 shows a relative rotation of 40 micro-arc-seconds, mostly about the Y-axis. Small shifts are also seen in the EOP's, the largest being 11 micro-arc-seconds in X-pole. Some small but insignificant differences are also seen in the TRF. These results will be presented and discussed.
Developing a passive load reduction blade for the DTU 10 MW reference turbine
NASA Astrophysics Data System (ADS)
de Vaal, J. B.; Nygaard, T. A.; Stenbro, R.
2016-09-01
This paper presents the development of a passive load reduction blade for the DTU 10 MW reference wind turbine, using the aero-hydro-servo-elastic analysis tool 3DFloat. Passive load reduction is achieved by introducing sweep to the path of the blade elastic axis, so that out-of-plane bending deflections result in load alleviating torsional deformations of the blade. Swept blades are designed to yield similar annual energy production as a rotor with a reference straight blade. This is achieved by modifying the aerodynamic twist distribution for swept blades based on non-linear blade deflection under steady state loads. The passive load reduction capability of a blade design is evaluated by running a selection of fatigue- and extreme load cases with the analysis tool 3DFloat and determining equivalent fatigue loads, fatigue damage and extreme loads at the blade root and tower base. The influence of sweep on the flutter speed of a blade design is also investigated. A large number of blade designs are evaluated by varying the parameters defining the sweep path of a blade's elastic axis. Results show that a moderate amount of sweep can effectively reduce equivalent fatigue damage and extreme loads, without significantly reducing the flutter speed, or compromising annual energy production.
Multipass Steering: A Reference Implementation
NASA Astrophysics Data System (ADS)
Hennessey, Michael; Tiefenback, Michael
2015-10-01
We introduce a reference implementation of a protocol to compute corrections that bring all beams in one of the CEBAF linear accelerators (linac) to axis, including, with a larger tolerance, the lowest energy pass using measured beam trajectory data. This method relies on linear optics as representation of the system; we treat beamline perturbations as magnetic field errors localized to regions between cryomodules, providing the same transverse momentum kick to each beam. We produce a vector of measured beam position data with which we left-multiply the pseudo-inverse of a coefficient array, A, that describes the transport of the beam through the linac using parameters that include the magnetic offsets of the quadrupole magnets, the instrumental offsets of the BPMs, and the beam initial conditions. This process is repeated using a reduced array to produce values that can be applied to the available correcting magnets and beam initial conditions. We show that this method is effective in steering the beam to a straight axis along the linac by using our values in elegant, the accelerator simulation program, on a model of the linac in question. The algorithms in this reference implementation provide a tool for systematic diagnosis and cataloging of perturbations in the beam line. Supported by Jefferson Lab, Old Dominion University, NSF, DOE.
Friction Effects on Inertia Compensators used for Heliostat Base Motion Isolation.
The base motion isolation of an optical beam deflector with a two-axis gimbal support ( heliostat ) is discussed. The use of an auxiliary inertia...coupled between the elevation gimbal and the heliostat mirror to produce a compensating torque referred to as a gear compensator and a belt compensator
HUMAN HEALTH DAMAGES FROM MOBILE SOURCE AIR POLLUTION: ADDITIONAL DELPHI DATA ANALYSIS. VOLUME II
The report contains the results of additional analyses of the data generated by a panel of medical experts for a study of Human Health Damages from Mobile Source Air Pollution (hereafter referred to as HHD) conducted by the California Air Resources Board in 1973-75 for the U.S. E...
ERIC Educational Resources Information Center
Nashif, Taysir
Technological education is more effective than general education in improving social mobility. Remarkable gender disparities currently exist in overall enrollment in secondary and higher education in the Arab states. Encouraging more Arab women to enroll in technological education would lead to higher percentages of women in higher-paying jobs,…
Learning Chinese Characters via Mobile Technology in a Primary School Classroom
ERIC Educational Resources Information Center
Lu, Jie; Meng, Sue; Tam, Vincent
2014-01-01
This paper describes a project, including the design, development, and use of a mobile application (referred to as application hereafter) for learning Chinese as a second language in a bilingual primary school. The application was designed for iPod Touch Apple technology with the purpose to facilitate learning of a fundamental set of 200 Chinese…
A Paleolatitude Calculator for Paleoclimate Studies
van Hinsbergen, Douwe J. J.; de Groot, Lennart V.; van Schaik, Sebastiaan J.; Spakman, Wim; Bijl, Peter K.; Sluijs, Appy; Langereis, Cor G.; Brinkhuis, Henk
2015-01-01
Realistic appraisal of paleoclimatic information obtained from a particular location requires accurate knowledge of its paleolatitude defined relative to the Earth’s spin-axis. This is crucial to, among others, correctly assess the amount of solar energy received at a location at the moment of sediment deposition. The paleolatitude of an arbitrary location can in principle be reconstructed from tectonic plate reconstructions that (1) restore the relative motions between plates based on (marine) magnetic anomalies, and (2) reconstruct all plates relative to the spin axis using a paleomagnetic reference frame based on a global apparent polar wander path. Whereas many studies do employ high-quality relative plate reconstructions, the necessity of using a paleomagnetic reference frame for climate studies rather than a mantle reference frame appears under-appreciated. In this paper, we briefly summarize the theory of plate tectonic reconstructions and their reference frames tailored towards applications of paleoclimate reconstruction, and show that using a mantle reference frame, which defines plate positions relative to the mantle, instead of a paleomagnetic reference frame may introduce errors in paleolatitude of more than 15° (>1500 km). This is because mantle reference frames cannot constrain, or are specifically corrected for the effects of true polar wander. We used the latest, state-of-the-art plate reconstructions to build a global plate circuit, and developed an online, user-friendly paleolatitude calculator for the last 200 million years by placing this plate circuit in three widely used global apparent polar wander paths. As a novelty, this calculator adds error bars to paleolatitude estimates that can be incorporated in climate modeling. The calculator is available at www.paleolatitude.org. We illustrate the use of the paleolatitude calculator by showing how an apparent wide spread in Eocene sea surface temperatures of southern high latitudes may be in part explained by a much wider paleolatitudinal distribution of sites than previously assumed. PMID:26061262
A Paleolatitude Calculator for Paleoclimate Studies.
van Hinsbergen, Douwe J J; de Groot, Lennart V; van Schaik, Sebastiaan J; Spakman, Wim; Bijl, Peter K; Sluijs, Appy; Langereis, Cor G; Brinkhuis, Henk
2015-01-01
Realistic appraisal of paleoclimatic information obtained from a particular location requires accurate knowledge of its paleolatitude defined relative to the Earth's spin-axis. This is crucial to, among others, correctly assess the amount of solar energy received at a location at the moment of sediment deposition. The paleolatitude of an arbitrary location can in principle be reconstructed from tectonic plate reconstructions that (1) restore the relative motions between plates based on (marine) magnetic anomalies, and (2) reconstruct all plates relative to the spin axis using a paleomagnetic reference frame based on a global apparent polar wander path. Whereas many studies do employ high-quality relative plate reconstructions, the necessity of using a paleomagnetic reference frame for climate studies rather than a mantle reference frame appears under-appreciated. In this paper, we briefly summarize the theory of plate tectonic reconstructions and their reference frames tailored towards applications of paleoclimate reconstruction, and show that using a mantle reference frame, which defines plate positions relative to the mantle, instead of a paleomagnetic reference frame may introduce errors in paleolatitude of more than 15° (>1500 km). This is because mantle reference frames cannot constrain, or are specifically corrected for the effects of true polar wander. We used the latest, state-of-the-art plate reconstructions to build a global plate circuit, and developed an online, user-friendly paleolatitude calculator for the last 200 million years by placing this plate circuit in three widely used global apparent polar wander paths. As a novelty, this calculator adds error bars to paleolatitude estimates that can be incorporated in climate modeling. The calculator is available at www.paleolatitude.org. We illustrate the use of the paleolatitude calculator by showing how an apparent wide spread in Eocene sea surface temperatures of southern high latitudes may be in part explained by a much wider paleolatitudinal distribution of sites than previously assumed.
Tetreault, J.; Jones, C.H.; Erslev, E.; Larson, S.; Hudson, M.; Holdaway, S.
2008-01-01
Significant fold-axis-parallel slip is accommodated in the folded strata of the Grayback monocline, northeastern Front Range, Colorado, without visible large strike-slip displacement on the fold surface. In many cases, oblique-slip deformation is partitioned; fold-axis-normal slip is accommodated within folds, and fold-axis-parallel slip is resolved onto adjacent strike-slip faults. Unlike partitioning strike-parallel slip onto adjacent strike-slip faults, fold-axis-parallel slip has deformed the forelimb of the Grayback monocline. Mean compressive paleostress orientations in the forelimb are deflected 15??-37?? clockwise from the regional paleostress orientation of the northeastern Front Range. Paleomagnetic directions from the Permian Ingleside Formation in the forelimb are rotated 16??-42?? clockwise about a bedding-normal axis relative to the North American Permian reference direction. The paleostress and paleomagnetic rotations increase with the bedding dip angle and decrease along strike toward the fold tip. These measurements allow for 50-120 m of fold-axis-parallel slip within the forelimb, depending on the kinematics of strike-slip shear. This resolved horizontal slip is nearly equal in magnitude to the ???180 m vertical throw across the fold. For 200 m of oblique-slip displacement (120 m of strike slip and 180 m of reverse slip), the true shortening direction across the fold is N90??E, indistinguishable from the regionally inferred direction of N90??E and quite different from the S53??E fold-normal direction. Recognition of this deformational style means that significant amounts of strike slip can be accommodated within folds without axis-parallel surficial faulting. ?? 2008 Geological Society of America.
Fletcher, Richard Ribón; Tam, Sharon; Omojola, Olufemi; Redemske, Richard; Kwan, Joyce
2011-01-01
We present a wearable sensor platform designed for monitoring and studying autonomic nervous system (ANS) activity for the purpose of mental health treatment and interventions. The mobile sensor system consists of a sensor band worn on the ankle that continuously monitors electrodermal activity (EDA), 3-axis acceleration, and temperature. A custom-designed ECG heart monitor worn on the chest is also used as an optional part of the system. The EDA signal from the ankle bands provides a measure sympathetic nervous system activity and used to detect arousal events. The optional ECG data can be used to improve the sensor classification algorithm and provide a measure of emotional "valence." Both types of sensor bands contain a Bluetooth radio that enables communication with the patient's mobile phone. When a specific arousal event is detected, the phone automatically presents therapeutic and empathetic messages to the patient in the tradition of Cognitive Behavioral Therapy (CBT). As an example of clinical use, we describe how the system is currently being used in an ongoing study for patients with drug-addiction and post-traumatic stress disorder (PTSD).
Dodds, James N; May, Jody C; McLean, John A
2017-11-21
Here we examine the relationship among resolving power (R p ), resolution (R pp ), and collision cross section (CCS) for compounds analyzed in previous ion mobility (IM) experiments representing a wide variety of instrument platforms and IM techniques. Our previous work indicated these three variables effectively describe and predict separation efficiency for drift tube ion mobility spectrometry experiments. In this work, we seek to determine if our previous findings are a general reflection of IM behavior that can be applied to various instrument platforms and mobility techniques. Results suggest IM distributions are well characterized by a Gaussian model and separation efficiency can be predicted on the basis of the empirical difference in the gas-phase CCS and a CCS-based resolving power definition (CCS/ΔCCS). Notably traveling wave (TWIMS) was found to operate at resolutions substantially higher than a single-peak resolving power suggested. When a CCS-based R p definition was utilized, TWIMS was found to operate at a resolving power between 40 and 50, confirming the previous observations by Giles and co-workers. After the separation axis (and corresponding resolving power) is converted to cross section space, it is possible to effectively predict separation behavior for all mobility techniques evaluated (i.e., uniform field, trapped ion mobility, traveling wave, cyclic, and overtone instruments) using the equations described in this work. Finally, we are able to establish for the first time that the current state-of-the-art ion mobility separations benchmark at a CCS-based resolving power of >300 that is sufficient to differentiate analyte ions with CCS differences as small as 0.5%.
Description of a Mobile-based Electronic Informed Consent System Development.
Hwang, Min-A; Kwak, In Ja
2015-01-01
Seoul National University Hospital constructed and implemented a computer-based informed consent system in December 2011. As of 2013, 30% of the informed consents were still filled out manually on paper. Patients and medical staff continuously suggested the implementation of a system for electronic informed consent using portable devices. Therefore, a mobile-based system for electronic informed consent was developed in 2013 to prevent the issues that arise with computer-based systems and paper informed consent. The rate of filling out electronic informed consent increased from 69% to 95% following the implementation of the mobile-based electronic informed consent. This construction of a mobile-based electronic informed consent system would be a good reference point for the development of a mobile-based Electronic Medical Record and for various mobile system environments in medical institutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varady, D.P.
This article is one of the first to test for the relative importance of concerns about public services in affecting residential mobility decisions over and beyond normal mobility factors. A secondary aim is to test for the validity of a residential mobility model formulated by Speare and associates. Multiple regression analysis was employed using 1974 to 1977 data from the longitudinal version of the Annual Housing Survey. Concerns about public services did not play a meaningful role in the analysis. This implies that efforts to hold middle-income residents in declining neighborhoods, through improved services, will not succeed. The results supportedmore » the Speare mobility model; housing satisfaction acted as an intermediary variable between background characteristics and mobility behavior. 30 references, 4 figures, 5 tables.« less
Safety Factors in Educational Facilities. An Annotated Reference List.
ERIC Educational Resources Information Center
Wakefield, Howard E.
Abstracts and descriptor terms are presented for 26 selected references with safety orientation. Included in addition to several general planning handbooks are topics related to--(1) stairways, (2) air structures, (3) site planning, (4) lighting, (5) bidding practice, (6) physically handicapped, (7) laboratory design, (8) mobile classrooms, (9)…
Point Cloud Refinement with a Target-Free Intrinsic Calibration of a Mobile Multi-Beam LIDAR System
NASA Astrophysics Data System (ADS)
Nouiraa, H.; Deschaud, J. E.; Goulettea, F.
2016-06-01
LIDAR sensors are widely used in mobile mapping systems. The mobile mapping platforms allow to have fast acquisition in cities for example, which would take much longer with static mapping systems. The LIDAR sensors provide reliable and precise 3D information, which can be used in various applications: mapping of the environment; localization of objects; detection of changes. Also, with the recent developments, multi-beam LIDAR sensors have appeared, and are able to provide a high amount of data with a high level of detail. A mono-beam LIDAR sensor mounted on a mobile platform will have an extrinsic calibration to be done, so the data acquired and registered in the sensor reference frame can be represented in the body reference frame, modeling the mobile system. For a multibeam LIDAR sensor, we can separate its calibration into two distinct parts: on one hand, we have an extrinsic calibration, in common with mono-beam LIDAR sensors, which gives the transformation between the sensor cartesian reference frame and the body reference frame. On the other hand, there is an intrinsic calibration, which gives the relations between the beams of the multi-beam sensor. This calibration depends on a model given by the constructor, but the model can be non optimal, which would bring errors and noise into the acquired point clouds. In the litterature, some optimizations of the calibration parameters are proposed, but need a specific routine or environment, which can be constraining and time-consuming. In this article, we present an automatic method for improving the intrinsic calibration of a multi-beam LIDAR sensor, the Velodyne HDL-32E. The proposed approach does not need any calibration target, and only uses information from the acquired point clouds, which makes it simple and fast to use. Also, a corrected model for the Velodyne sensor is proposed. An energy function which penalizes points far from local planar surfaces is used to optimize the different proposed parameters for the corrected model, and we are able to give a confidence value for the calibration parameters found. Optimization results on both synthetic and real data are presented.
NASA Astrophysics Data System (ADS)
Chen, Yuanpei; Wang, Lingcao; Li, Kui
2017-10-01
Rotary inertial navigation modulation mechanism can greatly improve the inertial navigation system (INS) accuracy through the rotation. Based on the single-axis rotational inertial navigation system (RINS), a self-calibration method is put forward. The whole system is applied with the rotation modulation technique so that whole inertial measurement unit (IMU) of system can rotate around the motor shaft without any external input. In the process of modulation, some important errors can be decoupled. Coupled with the initial position information and attitude information of the system as the reference, the velocity errors and attitude errors in the rotation are used as measurement to perform Kalman filtering to estimate part of important errors of the system after which the errors can be compensated into the system. The simulation results show that the method can complete the self-calibration of the single-axis RINS in 15 minutes and estimate gyro drifts of three-axis, the installation error angle of the IMU and the scale factor error of the gyro on z-axis. The calibration accuracy of optic gyro drifts could be about 0.003°/h (1σ) as well as the scale factor error could be about 1 parts per million (1σ). The errors estimate reaches the system requirements which can effectively improve the longtime navigation accuracy of the vehicle or the boat.
NASA Technical Reports Server (NTRS)
Burken, John J.; Burcham, Frank W., Jr.; Maine, Trindel A.; Feather, John; Goldthorpe, Steven; Kahler, Jeffrey A.
1996-01-01
A large, civilian, multi-engine transport MD-11 airplane control system was recently modified to perform as an emergency backup controller using engine thrust only. The emergency backup system, referred to as the propulsion-controlled aircraft (PCA) system, would be used if a major primary flight control system fails. To allow for longitudinal and lateral-directional control, the PCA system requires at least two engines and is implemented through software modifications. A flight-test program was conducted to evaluate the PCA system high-altitude flying characteristics and to demonstrate its capacity to perform safe landings. The cruise flight conditions, several low approaches and one landing without any aerodynamic flight control surface movement, were demonstrated. This paper presents results that show satisfactory performance of the PCA system in the longitudinal axis. Test results indicate that the lateral-directional axis of the system performed well at high attitude but was sluggish and prone to thermal upsets during landing approaches. Flight-test experiences and test techniques are also discussed with emphasis on the lateral-directional axis because of the difficulties encountered in flight test.
NASA Astrophysics Data System (ADS)
Gao, Chunfeng; Wei, Guo; Wang, Qi; Xiong, Zhenyu; Wang, Qun; Long, Xingwu
2016-10-01
As an indispensable equipment in inertial technology tests, the three-axis turntable is widely used in the calibration of various types inertial navigation systems (INS). In order to ensure the calibration accuracy of INS, we need to accurately measure the initial state of the turntable. However, the traditional measuring method needs a lot of exterior equipment (such as level instrument, north seeker, autocollimator, etc.), and the test processing is complex, low efficiency. Therefore, it is relatively difficult for the inertial measurement equipment manufacturers to realize the self-inspection of the turntable. Owing to the high precision attitude information provided by the laser gyro strapdown inertial navigation system (SINS) after fine alignment, we can use it as the attitude reference of initial state measurement of three-axis turntable. For the principle that the fixed rotation vector increment is not affected by measuring point, we use the laser gyro INS and the encoder of the turntable to provide the attitudes of turntable mounting plat. Through this way, the high accuracy measurement of perpendicularity error and initial attitude of the three-axis turntable has been achieved.
Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane.
Daniilidis, Kiriakos; Höll, Steffen; Gosheger, Georg; Dieckmann, Ralf; Martinelli, Nicolo; Ostermeier, Sven; Tibesku, Carsten O
2013-10-01
Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint. Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control. The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses. Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.
Orientation of human optokinetic nystagmus to gravity: a model-based approach
NASA Technical Reports Server (NTRS)
Gizzi, M.; Raphan, T.; Rudolph, S.; Cohen, B.
1994-01-01
Optokinetic nystagmus (OKN) was induced by having subjects watch a moving display in a binocular, head-fixed apparatus. The display was composed of 3.3 degrees stripes moving at 35 degrees/s for 45 s. It subtended 88 degrees horizontally by 72 degrees vertically of the central visual field and could be oriented to rotate about axes that were upright or tilted 45 degrees or 90 degrees. The head was held upright or was tilted 45 degrees left or right on the body during stimulation. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined and compared with the axis of stimulation and the spatial vertical (gravity axis). With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted, a significant vertical component of eye velocity appeared during yaw axis stimulation. As a result the axis of eye rotation shifted from the stimulus axis toward the spatial vertical. Vertical components developed within 1-2 s of stimulus onset and persisted until the end of stimulation. In the six subjects there was a mean shift of the axis of eye rotation during yaw axis stimulation of approximately 18 degrees with the head tilted 45 degrees on the body. Oblique optokinetic stimulation with the head upright was associated with a mean shift of the axis of eye rotation toward the spatial vertical of 9.2 degrees. When the head was tilted and the same oblique stimulation was given, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 degrees. This counterrotation of the axis of eye rotation is similar to the "Muller (E) effect," in which the perception of the upright is counterrotated to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN with a "direct" and "indirect" pathway. It was assumed that the direct visual pathway is oriented in a body, not a spatial frame of reference. Despite the short optokinetic after-nystagmus time constants, strong horizontal to vertical cross-coupling could be produced if the horizontal and vertical time constants were in proper ratio and there were no suppression of nystagmus in directions orthogonal to the stimulus direction. The model demonstrates that the spatial orientation of OKN can be achieved by restructuring the system matrix of velocity storage. We conclude that an important function of velocity storage is to orient slow-phase velocity toward the spatial vertical during movement in a terrestrial environment.
Franzén, Erika; Paquette, Caroline; Gurfinkel, Victor S; Cordo, Paul J; Nutt, John G; Horak, Fay B
2009-01-01
Rigidity or hypertonicity is a cardinal symptom of Parkinson's disease (PD). We hypothesized that hypertonicity of the body axis affects functional performance of tasks involving balance, walking and turning. The magnitude of axial postural tone in the neck, trunk and hip segments of 15 subjects with PD (both ON and OFF levodopa) and 15 control subjects was quantified during unsupported standing in an axial twisting device in our laboratory as resistance to torsional rotation. Subjects also performed six functional tests (walking in a figure of eight [Figure of Eight], Timed Up & Go, Berg Balance Scale, supine rolling task [rollover], Functional Reach, and standing 360-deg turn-in-place) in the ON and OFF state. Results showed that PD subjects had increased tone throughout the axis compared to control subjects (p=0.008) and that this increase was most prominent in the neck. In PD subjects, axial tone was related to functional performance, but most strongly for tone at the neck and accounted for an especially large portion of the variability in the performance of the Figure of Eight test (rOFF=0.68 and rON=0.74, p<0.05) and the Rollover test (rOFF=0.67and rON=0.55, p<0.05). Our results suggest that neck tone plays a significant role in functional mobility and that abnormally high postural tone may be an important contributor to balance and mobility disorders in individuals with PD. PMID:19573528
Hydride vapor phase epitaxy of high structural perfection thick AlN layers on off-axis 6H-SiC
NASA Astrophysics Data System (ADS)
Volkova, Anna; Ivantsov, Vladimir; Leung, Larry
2011-01-01
The employment of more than 10 μm thick AlN epilayers on SiC substrates for AlGaN/GaN high-electron-mobility transistors (HEMTs) substantially raises their performance in high-power energy-efficient amplifiers for 4G wireless mobile stations. In this paper, structural properties and surface morphology of thick AlN epilayers deposited by hydride vapor phase epitaxy (HVPE) on off-axis conductive 6H-SiC substrates are reported. The epilayers were examined in detail by high-resolution X-ray diffraction (XRD), atomic force microscopy (AFM), Nomarski differential interference contrast (DIC), scanning electron microscopy (SEM), and selective wet chemical etching. At optimal substrate preparation and growth conditions, a full width at half-maximum (FWHM) of the XRD rocking curve (RC) for the symmetric (00.2) reflex was very close to that of the substrate (less than 40 arcsec) suggesting low screw dislocation density in the epilayer (˜10 6 cm -2) and small in-plane tilt misorientation. Reciprocal space mapping around asymmetric reflexes and measured lattice parameters indicated a fully relaxed state of the epilayers. The unit-cell-high stepped areas of the epilayers with 0.5 nm root mean square (RMS) roughness over 1×1 μm 2 scan were alternated with step-bunching instabilities up to 350 nm in height. Low warp of the substrates makes them suitable for precise epitaxy of HEMT structures.
Mobile contract services: what you need to know.
Inman, M
2000-01-01
With sufficient planning and ongoing attention to detail, the performance of a mobile imaging service provider can exceed expectations and requirements. The relationship can prove to be mutually agreeable and profitable for many years. But, when contracting mobile services, you cannot spend too much time on initial research and detail. Several scenarios present outsourcing or mobile services as an acceptable alternative to purchase or lease: outdated equipment, novel or under-utilized technologies, the need for incrementally added or temporary service. To find suitable providers, check with peer sources in your area for recommendations; look specifically for facilities that are comparable in size and volume to your facility. Expect that larger volume facilities will rate more favorable schedules or pricing. Obtain and check references. Require mobile service providers to adhere to the same state and federal laws, rules and regulations that govern your facility; receive the assurance of compliance in writing if it is not specifically addressed in the contract. JCAHO requires that any contract service provider be governed by the same requirements as the accredited facility. Several other rules or licensing requirements may also pertain to mobile services. A prevailing reason for outsourcing imaging services is high equipment costs that cannot be justified with current volume projections. However, equipment quality should not be compromised; it must meet your needs and be in good repair. The mobile service provider you choose should be an extension of your department; quality standards must exist unilaterally. The set rule for assessing mobile service fees is that there is no set rule. There are many ways to negotiate the fee schedule so that it meets the needs of both parties. An effective marketing campaign lets physicians and patients know what you have available. Work with the mobile service provider to plan an initial announcement or open house. The mobile provider should also have patient education materials for referring physicians and your hospital. Having the mobile technologist meet with the radiologists to discuss written protocols will eliminate misunderstandings concerning expectations of both parties; ongoing communication is vital.
NASA Technical Reports Server (NTRS)
Garner, H. D. (Inventor)
1977-01-01
This invention employs a magnetometer as a magnetic heading reference for a vehicle such as a small aircraft. The magnetometer is mounted on a directional dial in the aircraft in the vicinity of the pilot such that it is free to turn with the dial about the yaw axis of the aircraft. The invention includes a circuit for generating a signal proportional to the northerly turning error produced in the magnetometer due to the vertical component of the earth's magnetic field. This generated signal is then subtracted from the output of the magnetometer to compensate for the northerly turning error.
NASA Technical Reports Server (NTRS)
Campbell, Stefan F.; Kaneshige, John T.
2010-01-01
Presented here is a Predictor-Based Model Reference Adaptive Control (PMRAC) architecture for a generic transport aircraft. At its core, this architecture features a three-axis, non-linear, dynamic-inversion controller. Command inputs for this baseline controller are provided by pilot roll-rate, pitch-rate, and sideslip commands. This paper will first thoroughly present the baseline controller followed by a description of the PMRAC adaptive augmentation to this control system. Results are presented via a full-scale, nonlinear simulation of NASA s Generic Transport Model (GTM).
Spontaneous magnetic alignment behaviour in free-living lizards.
Diego-Rasilla, Francisco J; Pérez-Mellado, Valentín; Pérez-Cembranos, Ana
2017-04-01
Several species of vertebrates exhibit spontaneous longitudinal body axis alignment relative to the Earth's magnetic field (i.e., magnetic alignment) while they are performing different behavioural tasks. Since magnetoreception is still not fully understood, studying magnetic alignment provides evidence for magnetoreception and broadens current knowledge of magnetic sense in animals. Furthermore, magnetic alignment widens the roles of magnetic sensitivity in animals and may contribute to shed new light on magnetoreception. In this context, spontaneous alignment in two species of lacertid lizards (Podarcis muralis and Podarcis lilfordi) during basking periods was monitored. Alignments in 255 P. muralis and 456 P. lilfordi were measured over a 5-year period. The possible influence of the sun's position (i.e., altitude and azimuth) and geomagnetic field values corresponding to the moment in which a particular lizard was observed on lizards' body axis orientation was evaluated. Both species exhibited a highly significant bimodal orientation along the north-northeast and south-southwest magnetic axis. The evidence from this study suggests that free-living lacertid lizards exhibit magnetic alignment behaviour, since their body alignments cannot be explained by an effect of the sun's position. On the contrary, lizard orientations were significantly correlated with geomagnetic field values at the time of each observation. We suggest that this behaviour might provide lizards with a constant directional reference while they are sun basking. This directional reference might improve their mental map of space to accomplish efficient escape behaviour. This study is the first to provide spontaneous magnetic alignment behaviour in free-living reptiles.
Spontaneous magnetic alignment behaviour in free-living lizards
NASA Astrophysics Data System (ADS)
Diego-Rasilla, Francisco J.; Pérez-Mellado, Valentín; Pérez-Cembranos, Ana
2017-04-01
Several species of vertebrates exhibit spontaneous longitudinal body axis alignment relative to the Earth's magnetic field (i.e., magnetic alignment) while they are performing different behavioural tasks. Since magnetoreception is still not fully understood, studying magnetic alignment provides evidence for magnetoreception and broadens current knowledge of magnetic sense in animals. Furthermore, magnetic alignment widens the roles of magnetic sensitivity in animals and may contribute to shed new light on magnetoreception. In this context, spontaneous alignment in two species of lacertid lizards ( Podarcis muralis and Podarcis lilfordi) during basking periods was monitored. Alignments in 255 P. muralis and 456 P. lilfordi were measured over a 5-year period. The possible influence of the sun's position (i.e., altitude and azimuth) and geomagnetic field values corresponding to the moment in which a particular lizard was observed on lizards' body axis orientation was evaluated. Both species exhibited a highly significant bimodal orientation along the north-northeast and south-southwest magnetic axis. The evidence from this study suggests that free-living lacertid lizards exhibit magnetic alignment behaviour, since their body alignments cannot be explained by an effect of the sun's position. On the contrary, lizard orientations were significantly correlated with geomagnetic field values at the time of each observation. We suggest that this behaviour might provide lizards with a constant directional reference while they are sun basking. This directional reference might improve their mental map of space to accomplish efficient escape behaviour. This study is the first to provide spontaneous magnetic alignment behaviour in free-living reptiles.
ERIC Educational Resources Information Center
Shircliffe, Barbara J.; Lance Rowland, M.
2015-01-01
This paper examines civic mobilization for school improvement in Rivergrove, a small suburban city within the inner rings of a large Florida metro (All names of individuals, schools, organizations and communities are pseudonyms per IRB agreement with district. Subsequently, references to local media reports and city documents are disguised to meet…
Learning on the Move: A Reassessment of Mobility through the Lens of Bateson's Learning Theory
ERIC Educational Resources Information Center
Janand, Anne; Notais, Amélie
2018-01-01
Purpose: This paper aims to explore the types of learning engendered by internal mobility (IM) by referring to the principles elaborated by Bateson (1972). Design/methodology/approach: A qualitative methodology is followed with interviews among 50 professionals working at four large French firms. Findings: A system of classification for IM is…
Developing the Next Generation NATO Reference Mobility Model
2016-06-27
acquisition • design UNCLASSIFIED: Distribution Statement A. Approved for public release; distribution is unlimited.(#27992) Vehicle Dynamics Model...and numerical resolution – for use in vehicle design , acquisition and operational mobility planning 27 June 2016 An open architecture was established...the current empirical methods for simulating vehicle and suspension designs . – Industry wide shortfall with tire dynamics and soft soil behavior
Mobile Fatwa (M-Fatwa): The Integration of Islamic Fatwa through Mobile Technology
ERIC Educational Resources Information Center
Nawi, Mohd Aliff Mohd; Hamzah, Mohd Isa
2014-01-01
Fatwa institutions play an important role to disseminate information about the fatwa decision that has been discussed. Fatwa is decided will be a guide and reference to the Muslims for dismantling all the problems related to religious law in everyday life. The purpose of this paper to discuss the integration method fatwa information using a mobile…
Regions of stability of asteroids
NASA Technical Reports Server (NTRS)
Szebehely, V.; Lundberg, J.; Vicente, R.
1983-01-01
Using Hill's modified stability criterion, regions of orbital elements are established for conditions of stability. The model of the three-dimensional restricted problem of three bodies is used with the sun and Jupiter as the primaries. Four different cases are studied: direct and retrograde, outside and inside asteroidal orbits. The directions of the asteroidal orbits refer to the synodical reference frame and the positions refer to Jupiter's orbit. The orbital parameters of the asteroids are the semi-major axis (a), the eccentricity (e), and the inclination from Jupiter's orbital plane (i). The argument of the perihelion and the longitude of the ascending node are fixed at Omega = omega = 90 deg and the time of perihelion passage is T = 0 for all orbits.
New osculating orbits for 110 comets and analysis of original orbits for 200 comets
NASA Technical Reports Server (NTRS)
Marsden, B. G.; Sekanina, Z.; Everhart, E.
1978-01-01
Osculating orbits are presented for 110 nearly parabolic comets. Combining these with selected orbit determinations from other sources, a total of 200 orbits are considered where the available observations yield a result of very good (first-class) or good (second-class) quality. For each of these, the original and future orbits (referred to the barycenter of the solar system) are calculated. The Oort effect (a tendency for original reciprocal semimajor axis values to range from zero to +100 millionths per AU) is clearly seen among the first-class orbits but not among the second-class orbits. Modifications in original reciprocal semimajor axis values due to the effects of nongravitational forces are considered.
Medically unexplained physical symptoms: toward an alternative paradigm for diagnosis and treatment.
Ballas, Christos A; Staab, Jeffrey P
2003-12-01
The treatment of patients with unexplained medical symptoms is difficult because there is neither a clear etiology for the symptoms, nor a useful paradigm with which to understand and treat them. Patients with such symptoms are often referred to psychiatry with vague diagnoses of "somatization" or "hypochondriasis." Rather than considering somatoform diagnoses based on the number or diversity of physical symptoms, evolving research suggests an emphasis on the type of physical symptom as an indicator of Axis I pathology. This article links specific symptomatic complaints, such as chronic pain, chest pain, and dizziness, to the respective Axis I disorders associated with them, such as depression, panic disorder, and anxiety disorders.
Biological and geochemical data of gravity cores from Mobile Bay, Alabama
Richwine, Kathryn A.; Marot, Marci; Smith, Christopher G.; Osterman, Lisa E.; Adams, C. Scott
2013-01-01
A study was conducted to understand the marine-influenced environments of Mobile Bay, Alabama, by collecting a series of box cores and gravity cores. One gravity core in particular demonstrates a long reference for changing paleoenvironmental parameters in Mobile Bay. Due to lack of abundance of foraminifers and (or) lack of diversity, the benthic foraminiferal data for two of the three gravity cores are not included in the results. The benthic foraminiferal data collected and geochemical analyses in this study provide a baseline for recent changes in the bay.
Jonsson, Frida; Sebastian, Miguel San; Hammarström, Anne; Gustafsson, Per E
2017-01-03
Research indicate that social class mobility could be potentially important for health, but whether this is due to the movement itself or a result of people having been integrated in different class contexts is, to date, difficult to infer. In addition, although several theories suggest that transitions between classes in the social hierarchy can be stressful experiences, few studies have empirically examined whether such movements may have health effects, over and above the implications of "being" in these classes. In an attempt to investigate whether intragenerational social mobility is associated with functional somatic symptoms in mid-adulthood, the current study tests three partially contrasting theories. The dissociative theory suggests that mobility in general and upward mobility in particular may be linked to psychological distress, while the falling from grace theory indicates that downward mobility is especially stressful. In contrast, the acculturation theory holds that the health implications of social mobility is not due to the movement itself but attributed to the class contexts in which people find themselves. Diagonal Reference Models were used on a sample of 924 individuals who in 1981 graduated from 9 th grade in the municipality of Luleå, Sweden. Social mobility was operationalized as change in occupational class between age 30 and 42 (measured in 1995 and 2007). The health outcome was functional somatic symptoms at age 42, defined as a clustering self-reported physical symptoms, palpitation and sleeping difficulties during the last 12 months. Overall mobility was not associated with higher levels of functional somatic symptoms compared to being immobile (p = 0.653). After controlling for prior and current class, sex, parental social position, general health, civil status, education and unemployment, the association between downward mobility was borderline significant (p = 0.055) while upward mobility was associated with lower levels of functional somatic symptoms (p = 0.03). The current study did not find unanimous support for any of the theories. Nevertheless, it sheds light on the possibility that upward mobility may be beneficial to reduce stress-related health problems in mid-life over and above the exposure to prior and current class, while downward mobility can be of less importance for middle-age health complaints.
NASA Astrophysics Data System (ADS)
Hutton, J. J.; Gopaul, N.; Zhang, X.; Wang, J.; Menon, V.; Rieck, D.; Kipka, A.; Pastor, F.
2016-06-01
For almost two decades mobile mapping systems have done their georeferencing using Global Navigation Satellite Systems (GNSS) to measure position and inertial sensors to measure orientation. In order to achieve cm level position accuracy, a technique referred to as post-processed carrier phase differential GNSS (DGNSS) is used. For this technique to be effective the maximum distance to a single Reference Station should be no more than 20 km, and when using a network of Reference Stations the distance to the nearest station should no more than about 70 km. This need to set up local Reference Stations limits productivity and increases costs, especially when mapping large areas or long linear features such as roads or pipelines. An alternative technique to DGNSS for high-accuracy positioning from GNSS is the so-called Precise Point Positioning or PPP method. In this case instead of differencing the rover observables with the Reference Station observables to cancel out common errors, an advanced model for every aspect of the GNSS error chain is developed and parameterized to within an accuracy of a few cm. The Trimble Centerpoint RTX positioning solution combines the methodology of PPP with advanced ambiguity resolution technology to produce cm level accuracies without the need for local reference stations. It achieves this through a global deployment of highly redundant monitoring stations that are connected through the internet and are used to determine the precise satellite data with maximum accuracy, robustness, continuity and reliability, along with advance algorithms and receiver and antenna calibrations. This paper presents a new post-processed realization of the Trimble Centerpoint RTX technology integrated into the Applanix POSPac MMS GNSS-Aided Inertial software for mobile mapping. Real-world results from over 100 airborne flights evaluated against a DGNSS network reference are presented which show that the post-processed Centerpoint RTX solution agrees with the DGNSS solution to better than 2.9 cm RMSE Horizontal and 5.5 cm RMSE Vertical. Such accuracies are sufficient to meet the requirements for a majority of airborne mapping applications.
Scala, Stefania
2015-10-01
Evidence suggests that the CXC-chemokine receptor-4 pathway plays a role in cancer cell homing and metastasis, and thus represents a potential target for cancer therapy. The homeostatic microenvironment chemokine CXCL12 binds the CXCR4 and CXCR7 receptors, activating divergent signals on multiple pathways, such as ERK1/2, p38, SAPK/JNK, AKT, mTOR, and the Bruton tyrosine kinase (BTK). An activating mutation in CXCR4 is responsible for a rare disease, WHIM syndrome (warts, hypogammaglobulinemia, infections, and myelokathexis), and dominant CXCR4 mutations have also been reported in Waldenstrom macroglobulinemia. The CXCR4-CXCL12 axis regulates the hematopoietic stem cell niche--a property that has led to the approval of the CXCR4 antagonist plerixafor (AMD3100) for mobilization of hematopoietic precursors. In preclinical models, plerixafor has shown antimetastatic potential in vivo, offering proof of concept. Other antagonists are in preclinical and clinical development. Recent evidence demonstrates that inhibiting CXCR4 signaling restores sensitivity to CTLA-4 and PD-1 checkpoint inhibitors, creating a new line for investigation. Targeting the CXCR4-CXCL12 axis thus offers the possibility of affecting CXCR4-expressing primary tumor cells, modulating the immune response, or synergizing with other targeted anticancer therapies. ©2015 American Association for Cancer Research.
Xu, Chengjian; Zhang, Wenxuan; He, Wenzhi; Li, Guangming; Huang, Juwen
2016-12-01
With the rapid development of electronic industry and improvement of living standards, a large number of waste mobile phones were generated. According to statistics, approximately 400million waste mobile phones are generated each year in the world, and 25% of that are contributed by China. Irregular disposal of waste mobile phones will do great harm to environment and human health, while at the same time recycling of them has the potential for high profits. Given the enormous quantity, great harm and resource properties, developed countries have taken necessary measures to manage waste mobile phones. As the largest developing country, China has also set out to pay close attention to waste mobile phones. This paper reviewed the situation ofwaste mobile phone management in the developed countries, focused on the development of waste mobile phone management in China, and analyzed existing problems. In light of the successful experience of the developed countries, some suggestions were proposed to promote the waste mobile phone management in China and worked as a valuable reference for other countries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Static Atmospheres in a Rotating Space Habitat.
ERIC Educational Resources Information Center
McKinley, John M.
1980-01-01
Discusses O'Neill's proposal for the colonization of space as it offers new problems in pure physics. Addresses specifically the distribution of the atmosphere in O'Neill's habitat and whether there will be enough air at the axis of rotation to allow human-powered flight, with particular reference to the habitat's "artificial gravity."…
Effects of Aeroelastic Tailoring on Anisotropic Composite Material Beam Models of Helicopter Blades
1989-05-01
34 means that a layer of material at some distance above a structural midsurface reference location has the identical ply thickness, angular orientation...and material properties as that of a lamina at an identical distance below the midsurface [1]. If the fibers are placed off-axis in the upper and
Crossmaps: Visualization of overlapping relationships in collections of journal papers
Morris, Steven A.; Yen, Gary G.
2004-01-01
A crossmapping technique is introduced for visualizing multiple and overlapping relations among entity types in collections of journal articles. Groups of entities from two entity types are crossplotted to show correspondence of relations. For example, author collaboration groups are plotted on the x axis against groups of papers (research fronts) on the y axis. At the intersection of each pair of author group/research front pairs a circular symbol is plotted whose size is proportional to the number of times that authors in the group appear as authors in papers in the research front. Entity groups are found by agglomerative hierarchical clustering using conventional similarity measures. Crossmaps comprise a simple technique that is particularly suited to showing overlap in relations among entity groups. Particularly useful crossmaps are: research fronts against base reference clusters, research fronts against author collaboration groups, and research fronts against term co-occurrence clusters. When exploring the knowledge domain of a collection of journal papers, it is useful to have several crossmaps of different entity pairs, complemented by research front timelines and base reference cluster timelines. PMID:14762168
NASA Technical Reports Server (NTRS)
Baumback, J. I.; Davies, A. N.; Vonirmer, A.; Lampen, P. H.
1995-01-01
To assist peak assignment in ion mobility spectrometry it is important to have quality reference data. The reference collection should be stored in a database system which is capable of being searched using spectral or substance information. We propose to build such a database customized for ion mobility spectra. To start off with it is important to quickly reach a critical mass of data in the collection. We wish to obtain as many spectra combined with their IMS parameters as possible. Spectra suppliers will be rewarded for their participation with access to the database. To make the data exchange between users and system administration possible, it is important to define a file format specially made for the requirements of ion mobility spectra. The format should be computer readable and flexible enough for extensive comments to be included. In this document we propose a data exchange format, and we would like you to give comments on it. For the international data exchange it is important, to have a standard data exchange format. We propose to base the definition of this format on the JCAMP-DX protocol, which was developed for the exchange of infrared spectra. This standard made by the Joint Committee on Atomic and Molecular Physical Data is of a flexible design. The aim of this paper is to adopt JCAMP-DX to the special requirements of ion mobility spectra.
Mullaji, Arun B; Shah, Siddharth; Shetty, Gautam M
2017-01-01
Background and purpose — Medial unicompartmental knee arthroplasty (UKA) is undertaken in patients with a passively correctable varus deformity. We investigated whether restoration of natural soft tissue tension would result in a lower limb alignment similar to that of the contralateral unaffected lower limb after mobile-bearing medial UKA. Patients and methods — In this retrospective study, hip-knee-ankle (HKA) angle, position of the weight-bearing axis (WBA), and knee joint line obliquity (KJLO) after mobile-bearing medial UKA was compared with that of the unaffected (clinically and radiologically) contralateral lower limb in 123 patients. Results — Postoperatively, HKA angle was restored to within ±3° of the contralateral lower limb in 87% of the patients and the WBA passed within ±1 Kennedy and White’s tibial zone of the unaffected contralateral lower limb in 95% of the patients. The mean KJLO in the operated limbs was not significantly different from that in the unaffected lower limbs (p = 0.07) and the KJLO in the operated limb was restored to within ±3° of that in the contralateral lower limb in 96% of the patients. Interpretation — Lower limb alignment and knee joint line obliquity after mobile-bearing medial UKA were comparable to that of the unaffected contralateral limb in most patients. Comparison with the contralateral unaffected lower limb is a reliable method for evaluation and validation of limb mechanical alignment after mobile-bearing medial UKA. PMID:27794622
Hydrodynamic interaction of two particles in confined linear shear flow at finite Reynolds number
NASA Astrophysics Data System (ADS)
Yan, Yiguang; Morris, Jeffrey F.; Koplik, Joel
2007-11-01
We discuss the hydrodynamic interactions of two solid bodies placed in linear shear flow between parallel plane walls in a periodic geometry at finite Reynolds number. The computations are based on the lattice Boltzmann method for particulate flow, validated here by comparison to previous results for a single particle. Most of our results pertain to cylinders in two dimensions but some examples are given for spheres in three dimensions. Either one mobile and one fixed particle or else two mobile particles are studied. The motion of a mobile particle is qualitatively similar in both cases at early times, exhibiting either trajectory reversal or bypass, depending upon the initial vector separation of the pair. At longer times, if a mobile particle does not approach a periodic image of the second, its trajectory tends to a stable limit point on the symmetry axis. The effect of interactions with periodic images is to produce nonconstant asymptotic long-time trajectories. For one free particle interacting with a fixed second particle within the unit cell, the free particle may either move to a fixed point or take up a limit cycle. Pairs of mobile particles starting from symmetric initial conditions are shown to asymptotically reach either fixed points, or mirror image limit cycles within the unit cell, or to bypass one another (and periodic images) indefinitely on a streamwise periodic trajectory. The limit cycle possibility requires finite Reynolds number and arises as a consequence of streamwise periodicity when the system length is sufficiently short.
In vivo kinematics of the salto total ankle prosthesis.
Leszko, Filip; Komistek, Richard D; Mahfouz, Mohamed R; Ratron, Yves-Alain; Judet, Thierry; Bonnin, Michel; Colombier, Jean-Alain; Lin, Sheldon S
2008-11-01
Recent technological advancements in total ankle arthroplasty (TAA) have included the introduction of the mobile bearing concept. This bearing has several advantages, but researchers have questioned whether or not increased mobility sacrifices joint stability or durability of the implant. The present study evaluated the kinematics of this type of prosthesis implanted in patients. Fluoroscopy and 3D-to-2D registration techniques were used to determine the in vivo kinematics for 20 TAA subjects performing two activities: gait and step-up. The motion of the prostheses was described in terms of clinical rotations and as rotation about the helical (screw) axis. Then, the anterior-posterior translation and axial rotation of the mobile bearing insert were determined. Among the clinical rotations, the dorsi-/plantarflexion was the most dominant, revealing the greatest pattern change and the largest magnitude. During gait, the orientation of the prosthetic components changed smoothly from plantarflexion to dorsiflexion. The average range of this motion was 9.2 degrees. For step-up activity, the range was 8.0 degrees. However, between 33% and 66% of stance phase, the talar component's orientation changed from dorsiflexion to plantarflexion. The average absolute range of anterior-posterior translation of the mobile bearing insert was 1.5 mm and 2.3 mm for gait and step-up, respectively. These measured translations were relatively small and may suggest that the rotational portion of the motion was more dominant than translational and provided sufficient mobility.
Monitoring and evaluation of rowing performance using mobile mapping data
NASA Astrophysics Data System (ADS)
Mpimis, A.; Gikas, V.
2011-12-01
Traditionally, the term mobile mapping refers to a means of collecting geospatial data using mapping sensors that are mounted on a mobile platform. Historically, this process was mainly driven by the need for highway infrastructure mapping and transportation corridor inventories. However, the recent advances in mapping sensor and telecommunication technologies create the opportunity that, completely new, emergent application areas of mobile mapping to evolve rapidly. This article examines the potential of mobile mapping technology (MMT) in sports science and in particular in competitive rowing. Notably, in this study the concept definition of mobile mapping somehow differs from the traditional one in a way that, the end result is not relevant to the geospatial information acquired as the moving platform travels in space. In contrast, the interest is placed on the moving platform (rowing boat) itself and on the various subsystems which are also in continuous motion.
Using Wireless Devices to Enhance Reference and Information Services
ERIC Educational Resources Information Center
Forsyth, Ellen
2006-01-01
A growing number of libraries have installed wireless data connections as a way of providing access to the Internet for members of the public. Some libraries have used their wireless networks to enable staff to use wireless devices to increase their mobility, effectiveness and responsiveness to client need particularly in providing reference and…
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... General § 25.109 Cross-reference. (a) Space and earth stations in the Amateur Satellite Service are licensed under 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile-Satellite Service transmitting in the 1626.5-1646.5 MHz band are subject to licensing under 47 CFR part 80. (c) Earth stations in...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... General § 25.109 Cross-reference. (a) Space and earth stations in the Amateur Satellite Service are licensed under 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile-Satellite Service transmitting in the 1626.5-1646.5 MHz band are subject to licensing under 47 CFR part 80. (c) Earth stations in...
The Gravity Probe B Experiment
NASA Technical Reports Server (NTRS)
Kolodziejczak, Jeffrey
2008-01-01
This presentation briefly describes the Gravity Probe B (GP-B) Experiment which is designed to measure parts of Einstein's general theory of relativity by monitoring gyroscope orientation relative to a distant guide star. To measure the miniscule angles predicted by Einstein's theory, it was necessary to build near-perfect gyroscopes that were approximately 50 million times more precise than the best navigational gyroscopes. A telescope mounted along the central axis of the dewar and spacecraft provided the experiment's pointing reference to a guide star. The telescope's image divide precisely split the star's beam into x-axis and y-axis components whose brightness could be compared. GP-B's 650-gallon dewar, kept the science instrument inside the probe at a cryogenic temperature for 17.3 months and also provided the thruster propellant for precision attitude and translation control. Built around the dewar, the GP-B spacecraft was a total-integrated system, comprising both the space vehicle and payload, dedicated as a single entity to experimentally testing predictions of Einstein's theory.
Phase derivative method for reconstruction of slightly off-axis digital holograms.
Guo, Cheng-Shan; Wang, Ben-Yi; Sha, Bei; Lu, Yu-Jie; Xu, Ming-Yuan
2014-12-15
A phase derivative (PD) method is proposed for reconstruction of off-axis holograms. In this method, a phase distribution of the tested object wave constrained within 0 to pi radian is firstly worked out by a simple analytical formula; then it is corrected to its right range from -pi to pi according to the sign characteristics of its first-order derivative. A theoretical analysis indicates that this PD method is particularly suitable for reconstruction of slightly off-axis holograms because it only requires the spatial frequency of the reference beam larger than spatial frequency of the tested object wave in principle. In addition, because the PD method belongs to a pure local method with no need of any integral operation or phase shifting algorithm in process of the phase retrieval, it could have some advantages in reducing computer load and memory requirements to the image processing system. Some experimental results are given to demonstrate the feasibility of the method.
Madeddu, Fabio; Prunas, Antonio; Hartmann, Diamante
2009-12-01
The aim of the present study is to assess the prevalence of Axis II disorders (DSM-IV-TR) in a sample of clients requesting sex reassignment surgery (SRS), consecutively admitted to a Gender Identity Disorder (GID) psychiatric unit. Fifty clients self-referred as transsexuals (34 biological males and 16 biological females; mean age = 31.74 +/- 7.06 years) were assessed through the SCID-II after a preliminary evaluation to exclude current major psychiatric disorders. Prevalence of any Axis II disorder was 52% (N = 26), with no significant differences related to biological sex. The most frequent personality disorders were Cluster B PDs (22% of total sample), followed by Cluster C (12%) and Cluster A PDs (2%). A significant prevalence of NOS PD (16%) was also found. Our data offers prevalence estimates slightly higher than those found in previous studies and does not provide evidence for any differences in the psychopathological profile and severity between MtF and FtM transsexuals.
Mobile platform for treatment of stroke: A case study of tele-assistance
Torres Zenteno, Arturo Henry; Fernández, Francisco; Palomino-García, Alfredo; Moniche, Francisco; Escudero, Irene; Jiménez-Hernández, M Dolores; Caballero, Auxiliadora; Escobar-Rodriguez, Germán; Parra, Carlos
2015-01-01
This article presents the technological solution of a tele-assistance process for stroke patients in acute phase in the Seville metropolitan area. The main objective of this process is to reduce time from symptom onset to treatment of acute phase stroke patients by means of telemedicine, regarding mobility between an intensive care unit ambulance and an expert center and activating the pre-hospital care phase. The technological platform covering the process has been defined following an interoperability model based on standards and with a focus on service-oriented architecture focus. Messaging definition has been designed according to the reference model of the CEN/ISO 13606, messages content follows the structure of archetypes. An XDS-b (Cross-Enterprise Document Sharing-b) transaction messaging has been designed according to Integrating the Healthcare Enterprise profile for archetype notifications and update enquiries.This research has been performed by a multidisciplinary group. The Virgen del Rocío University Hospital acts as Reference Hospital and the Public Company for Healthcare as mobility surroundings. PMID:25975806
Choudhri, Asim F; Radvany, Martin G
2011-04-01
Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.
Mardente, Stefania; Mari, Emanuela; Massimi, Isabella; Tafani, Marco; Guerriero, Raffaella; Morsilli, Ornella; Pulcinelli, Fabio M.; Bianchi, Marco E.; Zicari, Alessandra
2018-01-01
Platelets (PLTs) are the major source of high-mobility group box 1 (HMGB1), a protein that is involved in sterile inflammation of blood vessels and thrombosis. Megakaryocytes (MKs) synthesize HMGB1 and transfer both protein and mRNA into PLTs and PLT-derived microvesicles (MV). Free HMGB1 found in supernatants of in vitro differentiated MKs and in a megakaryoblastic cell line (DAMI cells). Aspirin “in vivo” and “in vitro” not only reduces HMGB1 and receptor for advanced glycation end products expression on MKs and PLTs but also drives the movement of HMGB1 from MKs into PLTs and PLT-derived MV. These findings suggest that consumption of low doses of aspirin reduces the risk of atherosclerosis complications as well as reducing PLT aggregation by the inhibition of COX-1. PMID:29375570
Crystal growth and electrical properties of CuFeO 2 single crystals
NASA Astrophysics Data System (ADS)
Dordor, P.; Chaminade, J. P.; Wichainchai, A.; Marquestaut, E.; Doumerc, J. P.; Pouchard, M.; Hagenmuller, P.; Ammar, A.
1988-07-01
Delafossite-type CuFeO 2 single crystals have been prepared by a flux method: crystals obtained in a Cu crucible with LiBO 2 as flux are n-type whereas those prepared in a Pt crucible with a Cu 2O flux are p-type. Electrical measurements have revealed that n-type crystals exhibit weak anisotropic conductivities with large activation energies and small mobilities (r.t. values perpendicular and parallel to the c-axis: μ⊥ = 5 × 10 -5 and μ‖ = 10 -7 cm -2 V -1 sec -1). p-type crystals, less anisotropic, are characterized by low activation energies and higher mobilities ( μ⊥ = 34 and μ‖ = 8.9 cm 2 V -1 sec -1). A two -conduction-band model is proposed to account for the difference observed between the energy gap value deduced from photoelectrochemical measurements and the activation energy of the electrical conductivity in the intrinsic domain.
Electric field-induced reversible trapping of microtubules along metallic glass microwire electrodes
NASA Astrophysics Data System (ADS)
Kim, Kyongwan; Sikora, Aurélien; Nakayama, Koji S.; Umetsu, Mitsuo; Hwang, Wonmuk; Teizer, Winfried
2015-04-01
Microtubules are among bio-polymers providing vital functions in dynamic cellular processes. Artificial organization of these bio-polymers is a requirement for transferring their native functions into device applications. Using electrophoresis, we achieve an accumulation of microtubules along a metallic glass (Pd42.5Cu30Ni7.5P20) microwire in solution. According to an estimate based on migration velocities of microtubules approaching the wire, the electrophoretic mobility of microtubules is around 10-12 m2/Vs. This value is four orders of magnitude smaller than the typical mobility reported previously. Fluorescence microscopy at the individual-microtubule level shows microtubules aligning along the wire axis during the electric field-induced migration. Casein-treated electrodes are effective to reversibly release trapped microtubules upon removal of the external field. An additional result is the condensation of secondary filamentous structures from oriented microtubules.
Research on modified the estimates of NOx emissions combined the OMI and ground-based DOAS technique
NASA Astrophysics Data System (ADS)
Zhang, Qiong; Li*, Ang; Xie, Pinhua; Hu, Zhaokun; Wu, Fengcheng; Xu, Jin
2017-04-01
A new method to calibrate nitrogen dioxide (NO2) lifetimes and emissions from point sources using satellite measurements base on the mobile passive differential optical absorption spectroscopy (DOAS) and multi axis differential optical absorption spectroscopy (MAX-DOAS) is described. It is based on using the Exponentially-Modified Gaussian (EMG) fitting method to correct the line densities along the wind direction by fitting the mobile passive DOAS NO2 vertical column density (VCD). An effective lifetime and emission rate are then determined from the parameters of the fit. The obtained results were then compared with the results acquired by fitting OMI (Ozone Monitoring Instrument) NO2 using the above fitting method, the NOx emission rate was about 195.8mol/s, 160.6mol/s, respectively. The reason why the latter less than the former may be because the low spatial resolution of the satellite.
Chalcogen doping at anionic site: A scheme towards more dispersive valence band in CuAlO2
NASA Astrophysics Data System (ADS)
Mazumder, Nilesh; Sen, Dipayan; Chattopadhyay, Kalyan Kumar
2013-02-01
Using first-principles calculations, we propose to enhance the dispersion of the top of valence band at high-symmetry points by selective introduction of chalcogen (Ch) impurities at oxygen site. As ab-plane hole mobility of CuAlO2 is large enough to support a band-conduction model over a polaronic one at room temperature [M. S. Lee et al. Appl. Phys. Lett. 79, 2029, (2001); J. Tate et al. Phys. Rev. B 80, 165206, (2009)], we examine its electronic and optical properties normal to c-axis. Intrinsic indirectness of energy-gap at Γ-point can be effectively removed along with substantial increase in density of states near Fermi level (EF) upon Ch addition. This can be attributed to S 2p-Cu 3d interaction just at or below EF, which should result in significantly improved carrier mobility and conductivity profile for this important p-type TCO.
Saedt, Eric R I C; Driehuis, Femke; Hoogeboom, Thomas J; van der Woude, Bé H; de Bie, Rob A; Nijhuis-van der Sanden, Maria W G
2018-01-01
The purpose of this study was to describe common clinical practices of manual therapists (MTs) in the Netherlands for infants with indications of upper cervical dysfunction (UCD). A prospective observational cohort study was conducted to gain insight into characteristics, reasons for seeking care, and common clinical practice for infants (<27 weeks) with indications of UCD, referred to MTs. Pre- and posttreatment self-reported questionnaires were used to collect data from parents and MTs. Parents reported on infant characteristics and perceived effect of treatment. Manual therapists reported on diagnostics, therapeutic procedures, and outcomes. Between 2006 and 2007, data regarding 307 referred infants (mean age: 11.2 weeks) were collected by parents and 42 MTs. The most frequent reasons for seeking care were positional preference, restlessness, and/or abnormal head position. Manual therapists observed active, spontaneous, and provoked mobility and passive upper cervical mobility. Of the 307 infants, 295 were diagnosed with UCD based on positive outcomes on the flexion-rotation test and/or lateral flexion test. After treatment with mobilization techniques, positive outcomes on the flexion-rotation test decreased from 78.8% to 6.8%. For the lateral flexion test, the positive outcomes decreased from 91.5% to 6.2%. All parents perceived positive treatment effects. No serious adverse events were reported during this study. This is the first study to describe common clinical practice for infants referred for manual therapy. Infants with UCD were treated mainly with upper cervical mobilization techniques, and the greatest perceived effect was observed after approximately 2 treatment sessions. Copyright © 2018. Published by Elsevier Inc.
2010-01-01
Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167
A Railway Track Geometry Measuring Trolley System Based on Aided INS
Chen, Qijin; Niu, Xiaoji; Zuo, Lili; Zhang, Tisheng; Xiao, Fuqin; Liu, Yi; Liu, Jingnan
2018-01-01
Accurate measurement of the railway track geometry is a task of fundamental importance to ensure the track quality in both the construction phase and the regular maintenance stage. Conventional track geometry measuring trolleys (TGMTs) in combination with classical geodetic surveying apparatus such as total stations alone cannot meet the requirements of measurement accuracy and surveying efficiency at the same time. Accurate and fast track geometry surveying applications call for an innovative surveying method that can measure all or most of the track geometric parameters in short time without interrupting the railway traffic. We provide a novel solution to this problem by integrating an inertial navigation system (INS) with a geodetic surveying apparatus, and design a modular TGMT system based on aided INS, which can be configured according to different surveying tasks including precise adjustment of slab track, providing tamping measurements, measuring track deformation and irregularities, and determination of the track axis. TGMT based on aided INS can operate in mobile surveying mode to significantly improve the surveying efficiency. Key points in the design of the TGMT’s architecture and the data processing concept and workflow are introduced in details, which should benefit subsequent research and provide a reference for the implementation of this kind of TGMT. The surveying performance of proposed TGMT with different configurations is assessed in the track geometry surveying experiments and actual projects. PMID:29439423
Conventional versus computer-navigated TKA: a prospective randomized study.
Todesca, Alessandro; Garro, Luca; Penna, Massimo; Bejui-Hugues, Jacques
2017-06-01
The purpose of this study was to assess the midterm results of total knee arthroplasty (TKA) implanted with a specific computer navigation system in a group of patients (NAV) and to assess the same prosthesis implanted with the conventional technique in another group (CON); we hypothesized that computer navigation surgery would improve implant alignment, functional scores and survival of the implant compared to the conventional technique. From 2008 to 2009, 225 patients were enrolled in the study and randomly assigned in CON and NAV groups; 240 consecutive mobile-bearing ultra-congruent score (Amplitude, Valence, France) TKAs were performed by a single surgeon, 117 using the conventional method and 123 using the computer-navigated approach. Clinical outcome assessment was based on the Knee Society Score (KSS), the Hospital for Special Surgery Knee Score and the Western Ontario Mac Master University Index score. Component survival was calculated by Kaplan-Meier analysis. Median follow-up was 6.4 years (range 6-7 years). Two patients were lost to follow-up. No differences were seen between the two groups in age, sex, BMI and side of implantation. Three patients of CON group referred feelings of instability during walking, but clinical tests were all negative. NAV group showed statistical significant better KSS Score and wider ROM and fewer outliers from neutral mechanical axis, lateral distal femoral angle, medial proximal tibial angle and tibial slope in post-operative radiographic assessment. There was one case of early post-operative superficial infection (caused by Staph. Aureus) successfully treated with antibiotics. No mechanical loosening, mobile-bearing dislocation or patellofemoral complication was seen. At 7 years of follow-up, component survival in relation to the risk of aseptic loosening or other complications was 100 %. There were no implant revisions. This study demonstrates superior accuracy in implant positioning and statistical significant better functional outcomes of computer-navigated TKA. Computer navigation for TKAs should be used routinely in primary implants. II.
Thomas, Silke; Kühnlein, Anja; Heinrich, Sabine; Praml, Georg; von Kries, Rüdiger; Radon, Katja
2008-11-04
Despite the increase of mobile phone use in the last decade and the growing concern whether mobile telecommunication networks adversely affect health and well-being, only few studies have been published that focussed on children and adolescents. Especially children and adolescents are important in the discussion of adverse health effects because of their possibly higher vulnerability to radio frequency electromagnetic fields. We investigated a possible association between exposure to mobile telecommunication networks and well-being in children and adolescents using personal dosimetry. A population-based sample of 1.498 children and 1.524 adolescents was assembled for the study (response 52%). Participants were randomly selected from the population registries of four Bavarian (South of Germany) cities and towns with different population sizes. During a Computer Assisted Personal Interview data on participants' well-being, socio-demographic characteristics and potential confounder were collected. Acute symptoms were assessed three times during the study day (morning, noon, evening).Using a dosimeter (ESM-140 Maschek Electronics), we obtained an exposure profile over 24 hours for three mobile phone frequency ranges (measurement interval 1 second, limit of determination 0.05 V/m) for each of the participants. Exposure levels over waking hours were summed up and expressed as mean percentage of the ICNIRP (International Commission on Non-Ionizing Radiation Protection) reference level. In comparison to non-participants, parents and adolescents with a higher level of education who possessed a mobile phone and were interested in the topic of possible adverse health effects caused by mobile telecommunication network frequencies were more willing to participate in the study. The median exposure to radio frequency electromagnetic fields of children and adolescents was 0.18% and 0.19% of the ICNIRP reference level respectively. In comparison to previous studies this is one of the first to assess the individual level of exposure to mobile telecommunication networks using personal dosimetry, enabling objective assessment of exposure from all sources and longer measurement periods. In total, personal dosimetry was proofed to be a well accepted tool to study exposure to mobile phone frequencies in epidemiologic studies including health effects on children and adolescents.
Evaluating Metrics of Drainage Divide Mobility
NASA Astrophysics Data System (ADS)
Forte, A. M.; Whipple, K. X.; DiBiase, R.; Gasparini, N. M.; Ouimet, W. B.
2016-12-01
Watersheds are the fundamental organizing units in landscapes and thus the controls on drainage divide location and mobility are an essential facet of landscape evolution. Additionally, many common topographic analyses fundamentally assume that river network topology and divide locations are largely static, allowing channel profile form to be interpreted in terms of spatio-temporal patterns of rock uplift rate relative to baselevel, climate, or rock properties. Recently however, it has been suggested that drainage divides are more mobile than previously thought and that divide mobility, and resulting changes in drainage area, can potentially induce changes to fluvial topography comparable to spatio-temporal variation in rock uplift, climate, or rock properties. Ultimately, reliable metrics are needed to diagnose the mobility of divides. One such recently proposed metric is cross-divide contrasts in `chi', a measure of the current topology of the drainage network, but cross-divide contrasts in a number of topographic metrics show promise. Here we use a series of landscape evolution modeling scenarios in which we induce divide mobility under different conditions to test the utility of a suite of plausible topographic metrics of divide mobility and compare these to natural examples. Specifically, we test cross-divide contrasts in mean slope, mean local relief, channel bed elevation at a reference drainage area, and chi. Our results highlight that cross-divide contrasts in chi can only be accurately interpreted in terms of divide mobility when uplift, rock erodibility, climate, and base-level are uniform across both river networks on either side of the divide. This is problematic for application of this metric to natural landscapes as (1) uniformity of all of these parameters is exceedingly unlikely and (2) quantifying the spatial patterns of these parameters is difficult. Consequently, as shown here for both simulated and natural landscapes, simple measures of cross-divide contrasts in mean slope, mean local relief, and channel bed elevation at a reference drainage area are more robust metrics of divide mobility, correctly identifying stable or mobile divides independent of cross-divide differences in rock uplift, climate, erodibility or baselevel.
Mobile Health Applications for Diabetes and Endocrinology: Promise and Peril?
Eng, Donna S; Lee, Joyce M.
2013-01-01
We are in the midst of what some have called a “mobile health revolution”. Medical applications ("apps") for mobile phones are proliferating in the marketplace and clinicians are likely encountering patients with questions about the medical value of these apps. We conducted a review of medical apps focused on endocrine disease. We found a higher percentage of relevant apps in our searches of the iPhone app store compared with the Android marketplace. For our diabetes search in the iPhone store, the majority of apps (33%) focused on health tracking (blood sugars, insulin doses, carbohydrates), requiring manual entry of health data. Only two apps directly inputted blood sugars from glucometers attached to the mobile phone. The remainder of diabetes apps were teaching/training apps (22%), food reference databases (8%), social blogs/forums (5%), and physician directed apps (8%). We found a number of insulin dose calculator apps which technically meet criteria for being a medically regulated mobile application, but did not find evidence for FDA-approval despite their availability to consumers. Far fewer apps were focused on other endocrine disease and included medical reference for the field of endocrinology, access to endocrine journals, height predictors, medication trackers, and fertility apps. Although mobile health apps have great potential for improving chronic disease care, they face a number of challenges including lack of evidence of clinical effectiveness, lack of integration with the health care delivery system, the need for formal evaluation and review and organized searching for health apps, and potential threats to safety and privacy. PMID:23627878
Schuttner, Linnaea; Sindano, Ntazana; Theis, Mathew; Zue, Cory; Joseph, Jessica; Chilengi, Roma; Chi, Benjamin H; Stringer, Jeffrey S A; Chintu, Namwinga
2014-08-01
Mobile health (m-health) utilizes widespread access to mobile phone technologies to expand health services. Community health workers (CHWs) provide first-level contact with health facilities; combining CHW efforts with m-health may be an avenue for improving primary care services. As part of a primary care improvement project, a pilot CHW program was developed using a mobile phone-based application for outreach, referral, and follow-up between the clinic and community in rural Zambia. The program was implemented at six primary care sites. Computers were installed at clinics for data entry, and data were transmitted to central servers. In the field, using a mobile phone to send data and receive follow-up requests, CHWs conducted household health surveillance visits, referred individuals to clinic, and followed up clinic patients. From January to April 2011, 24 CHWs surveyed 6,197 households with 33,304 inhabitants. Of 15,539 clinic visits, 1,173 (8%) had a follow-up visit indicated and transmitted via a mobile phone to designated CHWs. CHWs performed one or more follow-ups on 74% (n=871) of active requests and obtained outcomes on 63% (n=741). From all community visits combined, CHWs referred 840 individuals to a clinic. CHWs completed all planned aspects of surveillance and outreach, demonstrating feasibility. Components of this pilot project may aid clinical care in rural settings and have potential for epidemiologic and health system applications. Thus, m-health has the potential to improve service outreach, guide activities, and facilitate data collection in Zambia.
Schürer, M; Walter, A; Brünner, H; Langenbucher, A
2015-08-01
Colored transparent filters cause a change in color perception and have an impact on the perceptible amount of different colors and especially on the ability to discriminate between them. Yellow or orange tinted contact lenses worn to enhance contrast vision by reducing or blocking short wavelengths also have an effect on color perception. The impact of the yellow and orange tinted contact lenses Wöhlk SPORT CONTRAST on color discrimination was investigated with the Erlangen colour measurement system in a study with 14 and 16 subjects, respectively. In relation to a yellow reference color located at u' = 0.2487/v' = 0.5433, measurements of color discrimination thresholds were taken in up to 6 different color coordinate axes. Based on these thresholds, color discrimination ellipses were calculated. These results are given in the Derrington, Krauskopf and Lennie (DKL) color system. Both contact lenses caused a shift of the reference color towards higher saturated colors. Color discrimination ability with the yellow and orange colored lenses was significantly enhanced along the blue-yellow axis in comparison to the reference measurements without a tinted filter. Along the red-green axis only the orange lens caused a significant reduction of color discrimination threshold distance to the reference color. Yellow and orange tinted contact lenses enhance the ability of color discrimination. If the transmission spectra and the induced changes are taken into account, these results can also be applied to other filter media, such as blue filter intraocular lenses.
Absolute measurements of large mirrors
NASA Astrophysics Data System (ADS)
Su, Peng
The ability to produce mirrors for large astronomical telescopes is limited by the accuracy of the systems used to test the surfaces of such mirrors. Typically the mirror surfaces are measured by comparing their actual shapes to a precision master, which may be created using combinations of mirrors, lenses, and holograms. The work presented here develops several optical testing techniques that do not rely on a large or expensive precision, master reference surface. In a sense these techniques provide absolute optical testing. The Giant Magellan Telescope (GMT) has been designed with a 350 m 2 collecting area provided by a 25 m diameter primary mirror made out from seven circular independent mirror segments. These segments create an equivalent f/0.7 paraboloidal primary mirror consisting of a central segment and six outer segments. Each of the outer segments is 8.4 m in diameter and has an off-axis aspheric shape departing 14.5 mm from the best-fitting sphere. Much of the work in this dissertation is motivated by the need to measure the surfaces or such large mirrors accurately, without relying on a large or expensive precision reference surface. One method for absolute testing describing in this dissertation uses multiple measurements relative to a reference surface that is located in different positions with respect to the test surface of interest. The test measurements are performed with an algorithm that is based on the maximum likelihood (ML) method. Some methodologies for measuring large flat surfaces in the 2 m diameter range and for measuring the GMT primary mirror segments were specifically developed. For example, the optical figure of a 1.6-m flat mirror was determined to 2 nm rms accuracy using multiple 1-meter sub-aperture measurements. The optical figure of the reference surface used in the 1-meter sub-aperture measurements was also determined to the 2 nm level. The optical test methodology for a 1.7-m off axis parabola was evaluated by moving several times the mirror under test in relation to the test system. The result was a separation of errors in the optical test system to those errors from the mirror under test. This method proved to be accurate to 12nm rms. Another absolute measurement technique discussed in this dissertation utilizes the property of a paraboloidal surface of reflecting rays parallel to its optical axis, to its focal point. We have developed a scanning pentaprism technique that exploits this geometry to measure off-axis paraboloidal mirrors such as the GMT segments. This technique was demonstrated on a 1.7 m diameter prototype and proved to have a precision of about 50 nm rms.
2016-09-26
placement. The preamplifier mounted on top of the headset samples EEG signals at 300 Hz; it then transmits the raw EEG data via Bluetooth ® to a data...The preamplifier mounted on the back of the headset samples EEG signals at 256 Hz and then transmits the raw EEG data via Bluetooth ® to a data...electrooculography. The batteries will last 6 hours using Bluetooth ® or 16 hours if data are recorded directly onto a secure digital card. A three-axis
Organic Based Flexible Transistors and Electronic Device
2005-05-01
reactive groups that can act as charge carrier traps . 0.0 0.0 V1 ......3..... ... 10 " -.....-." . ;Z 0. - - -1,6 -V* /7VIDS -04O -2.5 10 -1.0 -0.8...of 2.5 kHz in vacuum with pentacene and DHFCO-4T with 7.5 ptm channel length devices. "* Ring oscillator frequencies of 10 kHz in air with pentacene ...similar herringbone packing in DFCO-4T (c) and DPCO-4T (d), respectively, viewed along the long crystallographic axis. Table 1. Charge carrier mobilities (A
Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta
2018-06-01
The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular pressure measurements in intensive care units. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
A three-dimensional axis for the study of femoral neck orientation
Bonneau, Noémie; Libourel, Paul-Antoine; Simonis, Caroline; Puymerail, Laurent; Baylac, Michel; Tardieu, Christine; Gagey, Olivier
2012-01-01
A common problem in the quantification of the orientation of the femoral neck is the difficulty to determine its true axis; however, this axis is typically estimated visually only. Moreover, the orientation of the femoral neck is commonly analysed using angles that are dependent on anatomical planes of reference and only quantify the orientation in two dimensions. The purpose of this study is to establish a method to determine the three-dimensional orientation of the femoral neck using a three-dimensional model. An accurate determination of the femoral neck axis requires a reconsideration of the complex architecture of the proximal femur. The morphology of the femoral neck results from both the medial and arcuate trabecular systems, and the asymmetry of the cortical bone. Given these considerations, two alternative models, in addition to the cylindrical one frequently assumed, were tested. The surface geometry of the femoral neck was subsequently used to fit one cylinder, two cylinders and successive cross-sectional ellipses. The model based on successive ellipses provided a significantly smaller average deviation than the two other models (P < 0.001) and reduced the observer-induced measurement error. Comparisons with traditional measurements and analyses on a sample of 91 femora were also performed to assess the validity of the model based on successive ellipses. This study provides a semi-automatic and accurate method for the determination of the functional three-dimensional femoral neck orientation avoiding the use of a reference plane. This innovative method has important implications for future studies that aim to document and understand the change in the orientation of the femoral neck associated with the acquisition of a bipedal gait in humans. Moreover, the precise determination of the three-dimensional orientation has implications in current research involved in developing clinical applications in diagnosis, hip surgery and rehabilitation. PMID:22967192
Mobile Technology for the Practice of Pathology.
Hartman, Douglas J
2016-03-01
Recently, several technological advances have been introduced to mobile phones leading some people to refer to them as "smartphones." These changes have led to widespread consumer adoption. A similar adoption has occurred within the medical field and this revolution is changing the practice of medicine, including pathology. Several mobile applications have been published for dermatology, orthopedics, ophthalmology, neurosurgery, and clinical pathology. The applications are wide ranging, including mobile technology to increase patient engagement, self-monitoring by patients, clinical algorithm calculation, facilitation between experts to resource-poor environments. These advances have been received with mixed reviews. For anatomic pathology, mobile technology applications can be broken into 4 broad categories: (a) educational uses, (b) microscope with mobile phone, (c) mobile phone as microscope/acquisition device, and (d) miscellaneous. Using a mobile phone as an acquisition device paired with a microscope seems to be the most interesting current application because of the need for expert consultation with resource-poor environments. However, several emerging uses for mobile technology may become more prominent as the technology matures including image analysis, alternative light sources, and increased opportunities for clinician and patient engagement. The flexibility represented by mobile technology represents a burgeoning field in pathology informatics.
ERIC Educational Resources Information Center
Toh, Yancy; So, Hyo-Jeong; Seow, Peter; Chen, Wenli; Looi, Chee-Kit
2013-01-01
This paper shares the theoretical and methodological frameworks that are deployed in a 3-year study to examine how Singapore primary school students leverage on mobile technology for seamless learning. This notion of seamless learning refers to the integrated and synergistic effects of learning in both formal and informal settings, which is…
Next-Generation NATO Reference Mobility Model (NG-NRMM)
2016-05-11
facilitate comparisons between vehicle design candidates and to assess the mobility of existing vehicles under specific scenarios. Although NRMM has...of different deployed platforms in different areas of operation and routes Improved flexibility as a design and procurement support tool through...Element Method DEM Digital Elevation Model DIL Driver in the Loop DP Drawbar Pull Force DOE Design of Experiments DTED Digital Terrain Elevation Data
ERIC Educational Resources Information Center
Glanzman, Allan; Ducret, Walter
2003-01-01
To select an adapted mobility device for a 5-year-old boy with blindness and spastic diplegic cerebral palsy, a multidisciplinary team used 8-millimeter videography to evaluate the subject's joint angle during ambulation with one of three canes and with no cane. The I-style cane provided optimal posture and gait pattern. (Contains references.) (CR)
Maintaining Limited-Range Connectivity Among Second-Order Agents
2016-07-07
we consider ad-hoc networks of robotic agents with double integrator dynamics. For such networks, the connectivity maintenance problems are: (i) do...hoc networks of mobile autonomous agents. This loose ter- minology refers to groups of robotic agents with limited mobility and communica- tion...connectivity can be preserved. 3.1. Networks of robotic agents with second-order dynamics and the connectivity maintenance problem. We begin by
Estimation Filter for Alignment of the Spitzer Space Telescope
NASA Technical Reports Server (NTRS)
Bayard, David
2007-01-01
A document presents a summary of an onboard estimation algorithm now being used to calibrate the alignment of the Spitzer Space Telescope (formerly known as the Space Infrared Telescope Facility). The algorithm, denoted the S2P calibration filter, recursively generates estimates of the alignment angles between a telescope reference frame and a star-tracker reference frame. At several discrete times during the day, the filter accepts, as input, attitude estimates from the star tracker and observations taken by the Pointing Control Reference Sensor (a sensor in the field of view of the telescope). The output of the filter is a calibrated quaternion that represents the best current mean-square estimate of the alignment angles between the telescope and the star tracker. The S2P calibration filter incorporates a Kalman filter that tracks six states - two for each of three orthogonal coordinate axes. Although, in principle, one state per axis is sufficient, the use of two states per axis makes it possible to model both short- and long-term behaviors. Specifically, the filter properly models transient learning, characteristic times and bounds of thermomechanical drift, and long-term steady-state statistics, whether calibration measurements are taken frequently or infrequently. These properties ensure that the S2P filter performance is optimal over a broad range of flight conditions, and can be confidently run autonomously over several years of in-flight operation without human intervention.
NASA Astrophysics Data System (ADS)
Suko, Ayaka; Jia, JunJun; Nakamura, Shin-ichi; Kawashima, Emi; Utsuno, Futoshi; Yano, Koki; Shigesato, Yuzo
2016-03-01
Amorphous indium-gallium-zinc oxide (a-IGZO) films were deposited by DC magnetron sputtering and post-annealed in air at 300-1000 °C for 1 h to investigate the crystallization behavior in detail. X-ray diffraction, electron beam diffraction, and high-resolution electron microscopy revealed that the IGZO films showed an amorphous structure after post-annealing at 300 °C. At 600 °C, the films started to crystallize from the surface with c-axis preferred orientation. At 700-1000 °C, the films totally crystallized into polycrystalline structures, wherein the grains showed c-axis preferred orientation close to the surface and random orientation inside the films. The current-gate voltage (Id-Vg) characteristics of the IGZO thin-film transistor (TFT) showed that the threshold voltage (Vth) and subthreshold swing decreased markedly after the post-annealing at 300 °C. The TFT using the totally crystallized films also showed the decrease in Vth, whereas the field-effect mobility decreased considerably.
A novel collinear optical system with annulus mirrors for holographic disc driver
NASA Astrophysics Data System (ADS)
Wang, Ye
2008-12-01
This paper focus on a novel collinear lens system with annulus mirrors for holographic disc driver, both information beam and reference beam are use same laser beam. The expanded and parallel laser beam, center part of it as the information beam then through Fourier transform lens, the beam around center part as a reference beam. On this axis, the ring reference beam reflected by two annulus shaped mirrors, then became a convergent beam, together with the information beam which through the first Fourier transform lens then produce holographic pattern to be write into the holographic disc behind of them, this lens system with two mirrors made the angle between information beam and reference beam more wide, can improved the multiplex level of holographic storage. Pair of Fourier transform lens with advance performance is designed in this paper.
A mobile mapping system for spatial information based on DGPS/EGIS
NASA Astrophysics Data System (ADS)
Pei, Ling; Wang, Qing; Gu, Juan
2007-11-01
With the rapid developments of mobile device and wireless communication, it brings a new challenge for acquiring the spatial information. A mobile mapping system based on differential global position system (DGPS) integrated with embedded geographic information system (EGIS) is designed. A mobile terminal adapts to various GPS differential environments such as single base mode and network GPS mode like Virtual Reference Station (VRS) and Master- Auxiliary Concept (MAC) by the mobile communication technology. The spatial information collected through DGPS is organized in an EGIS running in the embedded device. A set of mobile terminal in real-time DGPS based on GPRS adopting multithreading technique of serial port in manner of simulating overlapped I/O operating is developed, further more, the GPS message analysis and checkout based on Strategy Pattern for various receivers are included in the process of development. A mobile terminal accesses to the GPS network successfully by NTRIP (Networked Transport of RTCM via Internet Protocol) compliance. Finally, the accuracy and reliability of the mobile mapping system are proved by a lot of testing in 9 provinces all over the country.
Human mobility prediction from region functions with taxi trajectories.
Wang, Minjie; Yang, Su; Sun, Yi; Gao, Jun
2017-01-01
People in cities nowadays suffer from increasingly severe traffic jams due to less awareness of how collective human mobility is affected by urban planning. Besides, understanding how region functions shape human mobility is critical for business planning but remains unsolved so far. This study aims to discover the association between region functions and resulting human mobility. We establish a linear regression model to predict the traffic flows of Beijing based on the input referred to as bag of POIs. By solving the predictor in the sense of sparse representation, we find that the average prediction precision is over 74% and each type of POI contributes differently in the predictor, which accounts for what factors and how such region functions attract people visiting. Based on these findings, predictive human mobility could be taken into account when planning new regions and region functions.
NASA Astrophysics Data System (ADS)
Yamazaki, Taisei; Asubar, Joel T.; Tokuda, Hirokuni; Kuzuhara, Masaaki
2018-05-01
We investigated the impact of rounded electrode corners on the breakdown characteristics of AlGaN/GaN high-electron mobility transistors. For standard reference devices, catastrophic breakdown occurred predominantly near the sharp electrode corners. By introducing a rounded-electrode architecture, premature breakdown at the corners was mitigated. Moreover, the rate of breakdown voltage (V BR) degradation with an increasing gate width (W G) was significantly lower for devices with rounded corners. When W G was increased from 100 µm to 10 mm, the V BR of the reference device dropped drastically, from 1,200 to 300 V, whereas that of the rounded-electrode device only decreased to a respectable value of 730 V.
Communication: translational Brownian motion for particles of arbitrary shape.
Cichocki, Bogdan; Ekiel-Jeżewska, Maria L; Wajnryb, Eligiusz
2012-02-21
A single Brownian particle of arbitrary shape is considered. The time-dependent translational mean square displacement W(t) of a reference point at this particle is evaluated from the Smoluchowski equation. It is shown that at times larger than the characteristic time scale of the rotational Brownian relaxation, the slope of W(t) becomes independent of the choice of a reference point. Moreover, it is proved that in the long-time limit, the slope of W(t) is determined uniquely by the trace of the translational-translational mobility matrix μ(tt) evaluated with respect to the hydrodynamic center of mobility. The result is applicable to dynamic light scattering measurements, which indeed are performed in the long-time limit. © 2012 American Institute of Physics
NASA Astrophysics Data System (ADS)
Lu, Qun; Yu, Li; Zhang, Dan; Zhang, Xuebo
2018-01-01
This paper presentsa global adaptive controller that simultaneously solves tracking and regulation for wheeled mobile robots with unknown depth and uncalibrated camera-to-robot extrinsic parameters. The rotational angle and the scaled translation between the current camera frame and the reference camera frame, as well as the ones between the desired camera frame and the reference camera frame can be calculated in real time by using the pose estimation techniques. A transformed system is first obtained, for which an adaptive controller is then designed to accomplish both tracking and regulation tasks, and the controller synthesis is based on Lyapunov's direct method. Finally, the effectiveness of the proposed method is illustrated by a simulation study.
A generic sun-tracking algorithm for on-axis solar collector in mobile platforms
NASA Astrophysics Data System (ADS)
Lai, An-Chow; Chong, Kok-Keong; Lim, Boon-Han; Ho, Ming-Cheng; Yap, See-Hao; Heng, Chun-Kit; Lee, Jer-Vui; King, Yeong-Jin
2015-04-01
This paper proposes a novel dynamic sun-tracking algorithm which allows accurate tracking of the sun for both non-concentrated and concentrated photovoltaic systems located on mobile platforms to maximize solar energy extraction. The proposed algorithm takes not only the date, time, and geographical information, but also the dynamic changes of coordinates of the mobile platforms into account to calculate the sun position angle relative to ideal azimuth-elevation axes in real time using general sun-tracking formulas derived by Chong and Wong. The algorithm acquires data from open-loop sensors, i.e. global position system (GPS) and digital compass, which are readily available in many off-the-shelf portable gadgets, such as smart phone, to instantly capture the dynamic changes of coordinates of mobile platforms. Our experiments found that a highly accurate GPS is not necessary as the coordinate changes of practical mobile platforms are not fast enough to produce significant differences in the calculation of the incident angle. On the contrary, it is critical to accurately identify the quadrant and angle where the mobile platforms are moving toward in real time, which can be resolved by using digital compass. In our implementation, a noise filtering mechanism is found necessary to remove unexpected spikes in the readings of the digital compass to ensure stability in motor actuations and effectiveness in continuous tracking. Filtering mechanisms being studied include simple moving average and linear regression; the results showed that a compound function of simple moving average and linear regression produces a better outcome. Meanwhile, we found that a sampling interval is useful to avoid excessive motor actuations and power consumption while not sacrificing the accuracy of sun-tracking.
Phase-Contrast versus Off-Axis Illumination: Is a More Complex Microscope Always More Powerful?
ERIC Educational Resources Information Center
Hostounsky, Zdenek; Pelc, Radek
2007-01-01
In this article, a practical demonstration suitable for any biology college classroom is presented. With the examples of a complex biological specimen (slug's radula) and a simple reference specimen (electron microscopical grid imprint in gelatin), both of which can be easily prepared, the capabilities of two imaging modes commonly used in optical…
ERIC Educational Resources Information Center
Erickson, Michael; Ochoa, Romulo; Ochoa, Cris
2013-01-01
In 2010, the Wiimote was upgraded with three-axis gyroscopes that can measure rotational velocities up to 2000 deg/s. The improved remote is referred to as the Wii MotionPlus. We present experiments that use the gyroscope's capabilities and compare data acquired in lab settings with those obtained in playground environments. Van Hook et al.…
An approach to attitude determination for a spin-stabilized spacecraft (IMP 1)
NASA Technical Reports Server (NTRS)
Fang, A. C.
1972-01-01
The analysis and the FORTRAN program are presented for the determination of attitude of a spin-stabilized spacecraft. The use of telemetry data that provide information about two reference vectors and their relation to the spin is outlined. A technique for the determination of the spin-axis orientation that employs only simple calculations is described.
Use of personal digital assistants in diagnostic radiology resident education.
Nishino, Mizuki; Busch, James M; Wei, Jesse; Barbaras, Larry; Yam, Chun-Shan; Hatabu, Hiroto
2004-10-01
Personal digital assistants (PDAs) are gaining widespread use in the medical community. We introduced a PDA-based mobile system that provides departmental and educational information with a seamless connection to the intranet. The objective of this study is to determine the impact a PDA has on educational resources (learning or data reference) brought to work and used at home by a radiology resident based on user surveys. Survey was performed on 32 radiology residents in our department before and 6 months after the release of the PDA-based system. We assessed the changes in (1) sources of learning at home and at work, and in (2) data reference. The second survey also evaluated the usefulness of each component of the system. After the release of the PDA-based mobile system, the use of "digital books and references" as data references and educational resources that were brought to work every day significantly increased (P = .016, P < .0001, respectively). "Traditional books and references" remained the "most useful source in learning radiology"; however, "digital books and references" increased as the residents' first choice from 0% to 16% within 6 months of introducing the package (P = .125). The introduction of a PDA-based system consisting of educational and departmental information had a statistically significant impact in increasing the use of digitized information in radiology resident education.
Dobrev, Ivo; Sim, Jae Hoon; Aqtashi, Baktash; Huber, Alexander M; Linder, Thomas; Röösli, Christof
2018-01-01
Intra-operative quantification of the ossicle mobility could provide valuable feedback for the current status of the patient's conductive hearing. However, current methods for evaluation of middle ear mobility are mostly limited to the surgeon's subjective impression through manual palpation of the ossicles. This study investigates how middle ear transfer function is affected by stapes quasi-static stiffness of the ossicular chain. The stiffness of the middle ear is induced by a) using a novel fiber-optic 3-axis force sensor to quantify the quasi-static stiffness of the middle ear, and b) by artificial reduction of stapes mobility due to drying of the middle ear. Middle ear transfer function, defined as the ratio of the stapes footplate velocity versus the ear canal sound pressure, was measured with a single point LDV in two conditions. First, a controlled palpation force was applied at the stapes head in two in-plane (superior-inferior or posterior-anterior) directions, and at the incus lenticular process near the incudostapedial joint in the piston (lateral-medial) direction with a novel 3-axis PalpEar force sensor (Sensoptic, Losone, Switzerland), while the corresponding quasi-static displacement of the contact point was measured via a 3-axis micrometer stage. The palpation force was applied sequentially, step-wise in the range of 0.1-20 gF (1-200 mN). Second, measurements were repeated with various stages of stapes fixation, simulated by pre-load on the stapes head or drying of the temporal bone, and with severe ossicle immobilization, simulated by gluing of the stapes footplate. Simulated stapes fixation (forced drying of 5-15 min) severely decreases (20-30 dB) the low frequency (<1 kHz) response of the middle ear, while increasing (5-10 dB) the high frequency (>4 kHz) response. Stapes immobilization (gluing of the footplate) severely reduces (20-40 dB) the low and mid frequency response (<4 kHz) but has lesser effect (<10 dB) at higher frequencies. Even moderate levels of palpation force (<3gF, <30 mN), regardless of direction, have negative effect (10-20 dB) on the low frequency (<2 kHz) response, but with less significant (5-10 dB) effect at higher frequencies. Force-displacement measurements around the incudostapedial joint showed quasi-static stiffness in the range of 200-500 N/m for normal middle ears, and 1000-2500 N/m (5-8-fold increase) after artificially (through forced drying) reducing the middle ear transfer function with 10-25 dB at 1 kHz. Effects of the palpation force level and direction, as well as stapes fixation and immobilization have been analyzed based on the measurement of the stapes footplate motion, and controlled application of 3D force and displacement. Copyright © 2017 Elsevier B.V. All rights reserved.
Accuracy of various impression materials and methods for two implant systems: An effect size study.
Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd
2018-04-01
An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Routing in Mobile Wireless Sensor Networks: A Leader-Based Approach.
Burgos, Unai; Amozarrain, Ugaitz; Gómez-Calzado, Carlos; Lafuente, Alberto
2017-07-07
This paper presents a leader-based approach to routing in Mobile Wireless Sensor Networks (MWSN). Using local information from neighbour nodes, a leader election mechanism maintains a spanning tree in order to provide the necessary adaptations for efficient routing upon the connectivity changes resulting from the mobility of sensors or sink nodes. We present two protocols following the leader election approach, which have been implemented using Castalia and OMNeT++. The protocols have been evaluated, besides other reference MWSN routing protocols, to analyse the impact of network size and node velocity on performance, which has demonstrated the validity of our approach.
NASA Astrophysics Data System (ADS)
Yanchun, Wan; Qiucen, Chen
2017-11-01
Purchasing is an important part of export e-commerce of B2C, which plays an important role on risk and cost control in supply management. From the perspective of risk control, the paper construct a CVaR model for portfolio purchase. We select a heavy sales mobile power equipment from a typical B2C e-commerce export retailer as study sample. This study optimizes the purchasing strategy of this type of mobile power equipment. The research has some reference for similar enterprises in purchasing portfolio decision.
Historical development of the windmill
NASA Technical Reports Server (NTRS)
Shepherd, Dennis G.
1990-01-01
Throughout history, windmill technology represented the highest levels of development in those technical fields now referred to as mechanical engineering, civil engineering, and aerodynamics. Key stages are described in the technical development of windmills as prime movers; from antiquity to construction of the well known Smith-Putnam wind turbine generator of the 1940's, which laid the foundation for modern wind turbines. Subjects covered are windmills in ancient times; the vertical axis Persian windmill; the horizontal axis European windmill (including both post mills and tower mills); technology improvements in sails, controls, and analysis; the American farm windmill; the transition from windmills to wind turbines for generating electricity at the end of the 19th century; and wind turbine development in the first half of the 20th century.
Birefringence-balanced polarimetric optical fiber sensor for high-temperature measurements
NASA Technical Reports Server (NTRS)
Wang, Anbo; Wang, George Z.; Murphy, Kent A.; Claus, Richard O.
1992-01-01
A birefringence-balanced polarimetric multimode fiber temperature sensor is proposed and demonstrated. Two single-crystal sapphire rods are incorporated into the sensor head. They are connected end to end in such a way that the slow axis of the first rod is aligned with the fast axis of the second rod, referred to as the referencing rod. Since the lengths of the two rods are chosen to be almost the same, the original birefringence of the first rod is balanced by that of the second rod. A light-emitting diode serves as the light source. This sensor has been experimentally demonstrated for high-temperature measurements as high as 1500 C. A sensitivity of 5 C has been obtained.
NASA Technical Reports Server (NTRS)
Watson, Clifford
2010-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the twodimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and threedimensional charting gives a visual confirmation of the relationship between causes and their controls
NASA Technical Reports Server (NTRS)
Watson, Clifford C.
2011-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.
Risk Presentation Using the Three Dimensions of Likelihood, Severity, and Level of Control
NASA Technical Reports Server (NTRS)
Watson, Clifford
2010-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the leastwell-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.
Research on the measurement technology of effective arm length of swing arm profilometer
NASA Astrophysics Data System (ADS)
Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Li, Jie; Cao, Xuedong
2014-09-01
When the swing arm profilometer(SAP) measuring the mirror, the effective arm length of SAP which haves an obvious influence on the measurement results of the mirror surface shape needs to be measured accurately. It requires the measurement uncertainty of the effective arm length to reach 10μm in order to meet the measurement requirements, in this paper, we present a kind of technology based on laser tracker to measure the effective arm length of SAP. When the swing arm rotates around the shaft axis of swing arm rotary stage, the probe and two laser tracker balls form three sections of circular arc around the shaft axis of swing arm rotary stage in space. Laser tracker tracks and measures the circular arcs of two laser tracker balls, the center coordinates of the circular plane of circular arc can be calculated by data processing. The linear equation that passes through the two center coordinates is the equation of the shaft axis of rotary stage, the vertical distance from the probe to the shaft axis of rotary stage which can be calculated refer to the equation from the point to the line is the effective arm length. After Matlab simulation, this measurement method can meet the measurement accuracy.
1992-08-01
operations and feports, III )"NeforDvis, Highway uteI24, Arigt’on VA r ?0.3 anto the Offfice of Management and Bludgeti. Paflerwork Reduction Project (0704.0...variables jaw*" 50P* (S/ M1 / ir5 (IMMw / M1 / a 0,06.-O 001 324 Table 4 Coniectured Statistical Attributes of Parameters Selected for the Error
ERIC Educational Resources Information Center
Molara, Oyewusi Lawunmi; Joseph, Adamu Boladale
2014-01-01
When many authors were referring to radio and television as "new media" some years ago, little did they realize that a group of media, will later emerge that will sooner be termed "newer." The new development is about the adoption of mobile phones. These trends have emerged in many social contexts including participation in…
Rep. Alexander, Rodney [R-LA-5
2009-12-08
House - 03/29/2010 Referred to the Subcommittee on Department Operations, Oversight, Nutrition and Forestry. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
ERIC Educational Resources Information Center
Brown, Ceri
2012-01-01
This paper is concerned with the role of friendship in the construction of social capital within schools for students in poverty. It undertakes an analysis of friendship through the lens of students who have experienced turbulence. "Turbulence" refers to a type of pupil mobility between schools (not to be confused with social mobility) understood…
Commercial Mobile Alert Service (CMAS) Scenarios
2012-05-01
Commercial Mobile Alert Service (CMAS) Scenarios The WEA Project Team May 2012 SPECIAL REPORT CMU/SEI-2012-SR-020 CERT® Division, Software ...Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally...DISTRIBUTES IT “AS IS.” References herein to any specific commercial product, process, or service by trade name, trade mark, manufacturer, or otherwise
2015-04-24
csenatore@exponent.com (C. Senatore), paramsothy.jayakumar.civ@mail.mil (P. Jayakumar ), and kdi@mit.edu (K. Iagnemma). Report Documentation Page Form...in this paper were from the Reference (Senatore, Jayakumar , and Iagnemma, 2013). The study from which the experimental data were produced was...Lamb, D., Jayakumar , P., Letherwood, M., 2013. Investigating through simulation the mobility of light tracked vehicles operating on discrete granular
Tang, Wan; Chen, Min; Ni, Jin; Yang, Ximin
2011-01-01
The traditional Radio Frequency Identification (RFID) system, in which the information maintained in tags is passive and static, has no intelligent decision-making ability to suit application and environment dynamics. The Second-Generation RFID (2G-RFID) system, referred as 2G-RFID-sys, is an evolution of the traditional RFID system to ensure better quality of service in future networks. Due to the openness of the active mobile codes in the 2G-RFID system, the realization of conveying intelligence brings a critical issue: how can we make sure the backend system will interpret and execute mobile codes in the right way without misuse so as to avoid malicious attacks? To address this issue, this paper expands the concept of Role-Based Access Control (RBAC) by introducing context-aware computing, and then designs a secure middleware for backend systems, named Two-Level Security Enhancement Mechanism or 2L-SEM, in order to ensure the usability and validity of the mobile code through contextual authentication and role analysis. According to the given contextual restrictions, 2L-SEM can filtrate the illegal and invalid mobile codes contained in tags. Finally, a reference architecture and its typical application are given to illustrate the implementation of 2L-SEM in a 2G-RFID system, along with the simulation results to evaluate how the proposed mechanism can guarantee secure execution of mobile codes for the system. PMID:22163983
Tang, Wan; Chen, Min; Ni, Jin; Yang, Ximin
2011-01-01
The traditional Radio Frequency Identification (RFID) system, in which the information maintained in tags is passive and static, has no intelligent decision-making ability to suit application and environment dynamics. The Second-Generation RFID (2G-RFID) system, referred as 2G-RFID-sys, is an evolution of the traditional RFID system to ensure better quality of service in future networks. Due to the openness of the active mobile codes in the 2G-RFID system, the realization of conveying intelligence brings a critical issue: how can we make sure the backend system will interpret and execute mobile codes in the right way without misuse so as to avoid malicious attacks? To address this issue, this paper expands the concept of Role-Based Access Control (RBAC) by introducing context-aware computing, and then designs a secure middleware for backend systems, named Two-Level Security Enhancement Mechanism or 2L-SEM, in order to ensure the usability and validity of the mobile code through contextual authentication and role analysis. According to the given contextual restrictions, 2L-SEM can filtrate the illegal and invalid mobile codes contained in tags. Finally, a reference architecture and its typical application are given to illustrate the implementation of 2L-SEM in a 2G-RFID system, along with the simulation results to evaluate how the proposed mechanism can guarantee secure execution of mobile codes for the system.
Possible interpretation of the precession of comet 67P/Churyumov-Gerasimenko
NASA Astrophysics Data System (ADS)
Gutiérrez, P. J.; Jorda, L.; Gaskell, R. W.; Davidsson, B. J. R.; Capanna, C.; Hviid, S. F.; Keller, H. U.; Maquet, L.; Mottola, S.; Preusker, F.; Scholten, F.; Lara, L. M.; Moreno, F.; Rodrigo, R.; Sierks, H.; Barbieri, C.; Lamy, P.; Koschny, D.; Rickman, H.; Agarwal, J.; A'Hearn, M. F.; Auger, A. T.; Barucci, M. A.; Bertaux, J. L.; Bertini, I.; Cremonese, G.; Da Deppo, V.; Debei, S.; De Cecco, M.; El-Maarry, M. R.; Fornasier, S.; Fulle, M.; Groussin, O.; Gutiérrez-Marques, P.; Güttler, C.; Ip, W. H.; Knollenberg, J.; Kramm, J. R.; Kührt, E.; Küppers, M.; La Forgia, F.; Lazzarin, M.; López-Moreno, J. J.; Magrin, S.; Marchi, S.; Marzari, F.; Naletto, G.; Oklay, N.; Pajola, M.; Pommerol, A.; Sabau, D.; Thomas, N.; Toth, I.; Tubiana, C.; Vincent, J. B.
2016-05-01
Context. Data derived from the reconstruction of the nucleus shape of comet 67P/Churyumov-Gerasimenko (67P) from images of the OSIRIS camera onboard ROSETTA show evidence that the nucleus rotates in complex mode. First, the orientation of the spin axis is not fixed in an inertial reference frame, which suggests a precessing motion around the angular momentum vector with a periodicity of approximately 257 h ± 12 h.Second, periodograms of the right ascension and declination (RA/Dec) coordinates of the body-frame Z axis show a very significant (higher than 99.99%) periodicity at 276 h ± 12 h, different from the rotational period of 12.40 h as previously determined from light-curve analysis. Aims: The main goal is to interpret the data and associated periodicities of the spin axis orientation in space. Methods: We analyzed the spin axis orientation in space and associated periodicities and compared them with solutions of Euler equations under the assumption that the body rotates in torque-free conditions. Statistical tests comparing the observationally derived spin axis orientation with the outcome from simulations were applied to determine the most likely inertia moments, excitation level, and periods. Results: Under the assumption that the body is solid-rigid and rotates in torque-free conditions, the most likely interpretation is that 67P is spinning around the principal axis with the highest inertia moment with a period of about 13 h. At the same time, the comet precesses around the angular momentum vector with a period of about 6.35 h. While the rotating period of such a body would be about 12.4 h, RA/Dec coordinates of the spin axis would have a periodicity of about 270 h as a result of the combination of the two aforementioned motions. Conclusions: The most direct and simple interpretation of the complex rotation of 67P requires a ratio of inertia moments significantly higher than that of a homogeneous body.
The rainfall plot: its motivation, characteristics and pitfalls.
Domanska, Diana; Vodák, Daniel; Lund-Andersen, Christin; Salvatore, Stefania; Hovig, Eivind; Sandve, Geir Kjetil
2017-05-18
A visualization referred to as rainfall plot has recently gained popularity in genome data analysis. The plot is mostly used for illustrating the distribution of somatic cancer mutations along a reference genome, typically aiming to identify mutation hotspots. In general terms, the rainfall plot can be seen as a scatter plot showing the location of events on the x-axis versus the distance between consecutive events on the y-axis. Despite its frequent use, the motivation for applying this particular visualization and the appropriateness of its usage have never been critically addressed in detail. We show that the rainfall plot allows visual detection even for events occurring at high frequency over very short distances. In addition, event clustering at multiple scales may be detected as distinct horizontal bands in rainfall plots. At the same time, due to the limited size of standard figures, rainfall plots might suffer from inability to distinguish overlapping events, especially when multiple datasets are plotted in the same figure. We demonstrate the consequences of plot congestion, which results in obscured visual data interpretations. This work provides the first comprehensive survey of the characteristics and proper usage of rainfall plots. We find that the rainfall plot is able to convey a large amount of information without any need for parameterization or tuning. However, we also demonstrate how plot congestion and the use of a logarithmic y-axis may result in obscured visual data interpretations. To aid the productive utilization of rainfall plots, we demonstrate their characteristics and potential pitfalls using both simulated and real data, and provide a set of practical guidelines for their proper interpretation and usage.
Overall properties of the Gaia DR1 reference frame
NASA Astrophysics Data System (ADS)
Liu, N.; Zhu, Z.; Liu, J.-C.; Ding, C.-Y.
2017-03-01
Aims: The first Gaia data release (Gaia DR1) provides 2191 ICRF2 sources with their positions in the auxiliary quasar solution and five astrometric parameters - positions, parallaxes, and proper motions - for stars in common between the Tycho-2 catalogue and Gaia in the joint Tycho-Gaia astrometric solution (TGAS). We aim to analyze the overall properties of Gaia DR1 reference frame. Methods: We compare quasar positions of the auxiliary quasar solution with ICRF2 sources using different samples and evaluate the influence on the Gaia DR1 reference frame owing to the Galactic aberration effect over the J2000.0-J2015.0 period. Then we estimate the global rotation between TGAS with Tycho-2 proper motion systems to investigate the property of the Gaia DR1 reference frame. Finally, the Galactic kinematics analysis using the K-M giant proper motions is performed to understand the property of Gaia DR1 reference frame. Results: The positional comparison between the auxiliary quasar solution and ICRF2 shows negligible orientation and validates the declination bias of -0.1mas in Gaia quasar positions with respect to ICRF2. Galactic aberration effect is thought to cause an offset 0.01mas of the Z axis direction of Gaia DR1 reference frame. The global rotation between TGAS and Tycho-2 proper motion systems, obtained by different samples, shows a much smaller value than the claimed value 0.24mas yr-1. For the Galactic kinematics analysis of the TGAS K-M giants, we find possible non-zero Galactic rotation components beyond the classical Oort constants: the rigid part ωYG = -0.38±0.15mas yr-1 and the differential part ω^primeYG = -0.29±0.19mas yr-1 around the YG axis of Galactic coordinates, which indicates possible residual rotation in Gaia DR1 reference frame or problems in the current Galactic kinematical model. Conclusions: The Gaia DR1 reference frame is well aligned to ICRF2, and the possible influence of the Galactic aberration effect should be taken into consideration for the future Gaia-ICRF link. The cause of the rather small global rotation between TGAS and Tycho-2 proper motion systems is unclear and needs further investigation. The possible residual rotation in Gaia DR1 reference frame inferred from the Galactic kinematic analysis should be noted and examined in future data release.
Lavender, Danielle; Taraskin, Sergei N; Mason, Matthew J
2011-12-01
The middle ears of seven species of rodents, including four hamster species, were examined under light microscopy and through micro-CT imaging. Hamsters were found to possess a spectrum of ossicular morphologies ranging from something approaching "freely mobile" (Mesocricetus) to something nearer the "microtype" (Cricetulus), although no hamster has an orbicular apophysis of the malleus. Rats, mice and Calomyscus were found to have typically microtype ossicles. To explore the functional effects of these morphological differences, CT scan data were used to calculate the magnitudes of the moments of inertia and positions of the centres of mass and principal rotational axes for the malleus-incus complexes. Microtype species were found to have much greater ossicular inertias, relative to size, about the "anatomical axis" extending between anterior process of the malleus and short process of the incus; ossicular centres of mass were displaced further from this axis. Calculated inertial values were then put into an existing model of middle ear function (Hemilä et al., 1995), in order to see whether the more accurate data would improve predictions of upper hearing limits. For the rat and mouse they did, but this was not so for the hamster Mesocricetus. This might indicate that the inner rather than the middle ear limits hearing in this species, or might simply reflect other shortcomings of the model. Functional differences appear to exist even among rodent ears of the same general type, but the adaptive significance of these differences remains enigmatic. Copyright © 2011 Elsevier B.V. All rights reserved.
2003-09-12
VANDENBERG AFB, CALIF. - The mobile service tower on Space Launch Complex 2, Vandenberg Air Force Base, Calif., rolls back from the Delta II rocket that will launch the Gravity Probe B experiment. The Gravity Probe B will launch a payload of four gyroscopes into low-Earth polar orbit to test two extraordinary predictions of Albert Einstein’s general theory of relativity: the geodetic effect (how space and time are warped by the presence of the Earth) and frame dragging (how Earth’s rotation drags space and time around with it). Once in orbit, for 18 months each gyroscope’s spin axis will be monitored as it travels through local spacetime, observing and measuring these effects. The experiment was developed by Stanford University, Lockheed Martin and NASA’s Marshall Space Flight Center. The targeted launch date is Dec. 6, 2003.
15N NMR study of nitrate ion structure and dynamics in hydrotalcite-like compounds
Hou, X.; James, Kirkpatrick R.; Yu, P.; Moore, D.; Kim, Y.
2000-01-01
We report here the first nuclear magnetic resonance (NMR) spectroscopic study of the dynamical and structural behavior of nitrate on the surface and in the interlayer of hydrotalcite-like compounds (15NO3--HT). Spectroscopically resolvable surface-absorbed and interlayer NO3- have dramatically different dynamical characteristics. The interlayer nitrate shows a well defined, temperature independent uniaxial chemical shift anisotropy (CS A) powder pattern. It is rigidly held or perhaps undergoes rotation about its threefold axis at all temperatures between -100 ??C and +80 ??C and relative humidities (R.H.) from 0 to 100% at room temperature. For surface nitrate, however, the dynamical behavior depends substantially on temperature and relative humidity. Analysis of the temperature and R.H. dependences of the peak width yields reorieritational frequencies which increase from essentially 0 at -100 ??C to 2.6 ?? 105 Hz at 60 ??C and an activation energy of 12.6 kJ/mol. For example, for samples at R.H. = 33%, the surface nitrate is isotropically mobile at frequencies greater than 105 Hz at room temperature, but it becomes rigid or only rotates on its threefold axis at -100 ??C. For dry samples and samples heated at 200 ??C (R.H. near 0%), the surface nitrate is not isotropically averaged at room temperature. In contrast to our previous results for 35Cl--containing hydrotalcite (35Cl--HT), no NMR detectable structural phase transition is observed for 15NO3--HT. The mobility of interlayer nitrate in HT is intermediate between that of carbonate and chloride.
Addressing the Needs of Homeless Students.
ERIC Educational Resources Information Center
Holloway, John H.
2003-01-01
Reviews studies on the plight and needs of homeless students. Includes reports on family mobility and school attendance, dysfunctional families, and school intervention strategies. (Contains 11 references.) (PKP)
The promise and peril of mobile health applications for diabetes and endocrinology.
Eng, Donna S; Lee, Joyce M
2013-06-01
We are in the midst of what some have called a "mobile health revolution". Medical applications ("apps") for mobile phones are proliferating in the marketplace and clinicians are likely encountering patients with questions about the medical value of these apps. We conducted a review of medical apps focused on endocrine disease. We found a higher percentage of relevant apps in our searches of the iPhone app store compared with the Android marketplace. For our diabetes search in the iPhone store, the majority of apps (33%) focused on health tracking (blood sugars, insulin doses, carbohydrates), requiring manual entry of health data. Only two apps directly inputted blood sugars from glucometers attached to the mobile phone. The remainder of diabetes apps were teaching/training apps (22%), food reference databases (8%), social blogs/forums (5%), and physician directed apps (8%). We found a number of insulin dose calculator apps which technically meet criteria for being a medically regulated mobile application, but did not find evidence for FDA-approval despite their availability to consumers. Far fewer apps were focused on other endocrine disease and included medical reference for the field of endocrinology, access to endocrine journals, height predictors, medication trackers, and fertility apps. Although mobile health apps have great potential for improving chronic disease care, they face a number of challenges including lack of evidence of clinical effectiveness, lack of integration with the health care delivery system, the need for formal evaluation and review and organized searching for health apps, and potential threats to safety and privacy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Tomar, J.; Yadav, B. K.
2016-12-01
The aim of this study is to investigate the soil water flow and nitrate movement through vadose zone considering mobile-immobile approach using large scale three dimensional (3D) tank setup. The three dimensional sand tank setup was fabricated having dimension of 60 cm length, 30 cm width and 60 cm height and embedded with horizontal and vertical layers of sampling ports. The tank was filled with a porous media of average size of 0.5 to 1.0 mm homogeneous and nitrate concentration of 300 mg/l was applied with a distributed constant water flux of 150ml/hr. at the top using a sprinkler system. Pore water samples were collected hourly from the sampling ports and were analyzed using UV-spectrophotometer. The soil hydraulic and solute transport parameters were deduced from the laboratory experiments for simulating the considered 3D domain using the mobile-immobile approach. Soil moisture flow and contaminant transport equations are numerically solved for simulating the nitrate movement in the tank setup. The simulated break through curves (BTC) show the nitrate movement is rapid in mobile region by a factor of 1.2 as compared with the immobile region. The results show that the mobile-immobile approach of predicting solute transport in variably saturated zone can be used effectively in field after getting the required parameters using the laboratory experiments under similar environmental conditions. The high concentration 130 ppm was observed in lateral and transverse axis at 05 cm depth. This results will help in further investigation in field and in implementation of decontamination techniques.
How to identify, assess and utilise mobile medical applications in clinical practice.
Aungst, T D; Clauson, K A; Misra, S; Lewis, T L; Husain, I
2014-02-01
There are thousands of medical applications for mobile devices targeting use by healthcare professionals. However, several factors related to the structure of the existing market for medical applications create significant barriers preventing practitioners from effectively identifying mobile medical applications for individual professional use. To define existing market factors relevant to selection of medical applications and describe a framework to empower clinicians to identify, assess and utilise mobile medical applications in their own practice. Resources available on the Internet regarding mobile medical applications, guidelines and published research on mobile medical applications. Mobile application stores (e.g. iTunes, Google Play) are not effective means of identifying mobile medical applications. Users of mobile devices that desire to implement mobile medical applications into practice need to carefully assess individual applications prior to utilisation. Searching and identifying mobile medical applications requires clinicians to utilise multiple references to determine what application is best for their individual practice methods. This can be done with a cursory exploration of mobile application stores and then moving onto other available resources published in the literature or through Internet resources (e.g. blogs, medical websites, social media). Clinicians must also take steps to ensure that an identified mobile application can be integrated into practice after carefully reviewing it themselves. Clinicians seeking to identify mobile medical application for use in their individual practice should use a combination of app stores, published literature, web-based resources, and personal review to ensure safe and appropriate use. © 2014 John Wiley & Sons Ltd.
Determining the Effectiveness Of Flexible Checkpoints
DOT National Transportation Integrated Search
2017-05-01
Flexible checkpoints are sometimes referred to as phantom checkpoints, public awareness checkpoints, mobile awareness patrols, and mock checkpoints. This checkpoint strategy involves staging a checkpoint, but not actually staf...
Rep. Filner, Bob [D-CA-51
2011-01-19
House - 03/23/2011 Referred to the Subcommittee on Insurance, Housing and Community Opportunity. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Mouzon, Dawne M; Watkins, Daphne C; Perry, Ramona; Simpson, Theresa M; Mitchell, Jamie A
2018-04-02
Goal-striving stress refers to the psychological consequences of seeking but failing to reach upward mobility and is more common among low-income and people of color. Intergenerational mobility-or improved socioeconomic standing relative to one's parents-may be an important predictor of goal-striving stress for Blacks. We used the National Survey of American Life to investigate the association between intergenerational mobility and goal-striving stress among U.S.-born African Americans, U.S.-born Caribbean Blacks, and foreign-born Caribbean Blacks. Intergenerational mobility was associated with lower goal-striving stress and U.S.-born African Americans and Caribbean Blacks reported lower goal-striving stress than foreign-born Caribbean Blacks. Goal-striving stress was relatively high among foreign-born Blacks, regardless of level of intergenerational mobility attained. Goal-striving is an important stressor for foreign-born Caribbean Blacks, regardless of their level of educational success. Given increasing Black migration, future studies should disaggregate the Black racial category based on ethnicity and nativity.
Tesfalul, Martha; Littman-Quinn, Ryan; Antwi, Cynthia; Ndlovu, Siphiwo; Motsepe, Didintle; Phuthego, Motsholathebe; Tau, Boitumelo; Mohutsiwa-Dibe, Neo
2016-01-01
Mobile telemedicine involves the use of mobile device (e.g., cell phones, tablets) technology to exchange information to assist in the provision of patient care. Throughout the world, mobile telemedicine initiatives are increasing in number and in scale, but literature on their impact on patient outcomes in low-resource areas is limited. This study explores the potential impact of a mobile oral telemedicine system on the oral health specialty referral system in Botswana. Analysis of 26 eligible cases from June 2012 to July 2013 reveals high diagnosis concordance between dental officers and oral health specialists at 91.3% (21/23) but significant management plan discordance at 64.0% (16/25), over two-thirds of which involved the specialists disagreeing with the referring clinicians about the need for a visit to a specialist. These findings suggest mobile telemedicine can optimize the use of insights and skills of specialists remotely in regions where they are scarce. PMID:26510877
Human mobility prediction from region functions with taxi trajectories
Wang, Minjie; Sun, Yi; Gao, Jun
2017-01-01
People in cities nowadays suffer from increasingly severe traffic jams due to less awareness of how collective human mobility is affected by urban planning. Besides, understanding how region functions shape human mobility is critical for business planning but remains unsolved so far. This study aims to discover the association between region functions and resulting human mobility. We establish a linear regression model to predict the traffic flows of Beijing based on the input referred to as bag of POIs. By solving the predictor in the sense of sparse representation, we find that the average prediction precision is over 74% and each type of POI contributes differently in the predictor, which accounts for what factors and how such region functions attract people visiting. Based on these findings, predictive human mobility could be taken into account when planning new regions and region functions. PMID:29190708
Energy Assessment of Automated Mobility Districts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yuche
Automated vehicles (AVs) are increasingly being discussed as the basis for on-demand mobility services, introducing a new paradigm in which a fleet of AVs displace private automobiles for day-to-day travel in dense activity districts. This project examines such a concept to displace privately owned automobiles within a region containing dense activity generators (jobs, retail, entertainment, etc.), referred to as an automated mobility district (AMDs). The project reviews several such districts including airport, college campuses, business parks, downtown urban cores, and military bases, with examples of previous attempts to meet the mobility needs apart from private automobiles, some with automated technologymore » and others with more traditional transit based solutions. The issues and benefits of AMDs are framed within the perspective of intra-district, inter-district, and border issues, and the requirements for a modeling framework are identified to adequately reflect the breadth of mobility, energy, and emissions impact anticipated with AMDs.« less
The impact of occupational load carriage on carrier mobility: a critical review of the literature.
Carlton, Simon D; Orr, Robin M
2014-01-01
Military personnel and firefighters are required to carry occupational loads and complete tasks in hostile and unpredictable environments where a lack of mobility may risk lives. This review critically examines the literature investigating the impacts of load carriage on the mobility of these specialist personnel. Several literature databases, reference lists, and subject matter experts were employed to identify relevant studies. Studies meeting the inclusion criteria were critiqued using the Downs and Black protocol. Inter-rater agreement was determined by Cohen's κ. Twelve original research studies, which included male and female participants from military and firefighting occupations, were critiqued (κ = .81). A review of these papers found that as the carried load weight increased, carrier mobility during aerobic tasks (like road marching) and anaerobic tasks (like obstacle course negotiation) decreased. As such, it can be concluded that the load carried by some specialist personnel may increase their occupational risk by reducing their mobility.
Mobile robot motion estimation using Hough transform
NASA Astrophysics Data System (ADS)
Aldoshkin, D. N.; Yamskikh, T. N.; Tsarev, R. Yu
2018-05-01
This paper proposes an algorithm for estimation of mobile robot motion. The geometry of surrounding space is described with range scans (samples of distance measurements) taken by the mobile robot’s range sensors. A similar sample of space geometry in any arbitrary preceding moment of time or the environment map can be used as a reference. The suggested algorithm is invariant to isotropic scaling of samples or map that allows using samples measured in different units and maps made at different scales. The algorithm is based on Hough transform: it maps from measurement space to a straight-line parameters space. In the straight-line parameters, space the problems of estimating rotation, scaling and translation are solved separately breaking down a problem of estimating mobile robot localization into three smaller independent problems. The specific feature of the algorithm presented is its robustness to noise and outliers inherited from Hough transform. The prototype of the system of mobile robot orientation is described.
Valley polarization in bismuth
NASA Astrophysics Data System (ADS)
Fauque, Benoit
2013-03-01
The electronic structure of certain crystal lattices can contain multiple degenerate valleys for their charge carriers to occupy. The principal challenge in the development of valleytronics is to lift the valley degeneracy of charge carriers in a controlled way. In bulk semi-metallic bismuth, the Fermi surface includes three cigar-shaped electron valleys lying almost perpendicular to the high symmetry axis known as the trigonal axis. The in-plane mass anisotropy of each valley exceeds 200 as a consequence of Dirac dispersion, which drastically reduces the effective mass along two out of the three orientations. According to our recent study of angle-dependent magnetoresistance in bismuth, a flow of Dirac electrons along the trigonal axis is extremely sensitive to the orientation of in-plane magnetic field. Thus, a rotatable magnetic field can be used as a valley valve to tune the contribution of each valley to the total conductivity. As a consequence of a unique combination of high mobility and extreme mass anisotropy in bismuth, the effect is visible even at room temperature in a magnetic field of 1 T. Thus, a modest magnetic field can be used as a valley valve in bismuth. The results of our recent investigation of angle-dependent magnetoresistance in other semi-metals and doped semiconductors suggest that a rotating magnetic field can behave as a valley valve in a multi-valley system with sizeable mass anisotropy.
James, David T; Frost, Jarvist M; Wade, Jessica; Nelson, Jenny; Kim, Ji-Seon
2013-09-24
The consideration of anisotropic structural properties and their impact on optoelectronic properties in small-molecule thin films is vital to understand the performance of devices incorporating crystalline organic semiconductors. Here we report on the important relationship between structural and optoelectronic anisotropy in aligned, functionalized-pentacene thin films fabricated using the solution-based zone-casting technique. The microstructure of thin films composed of 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-pentacene) and 6,13-bis(triethylsilylethynyl)pentacene (TES-pentacene) is systematically controlled by varying the casting speed. By controlling the structural alignment, we were able to experimentally decouple, for the first time in these films, an intramolecular absorption transition dipole (at ∼440 nm) oriented close to the pentacene short axis and an intermolecular absorption transition dipole (at ∼695 nm) oriented predominantly along the conjugated pentacene-pentacene core stacking axis (crystallographic a-axis) in both films. Using the intermolecular absorption as a signature for intermolecular delocalization, much higher optical dichroism was obtained in TES-pentacene (16 ± 6) than TIPS-pentacene (3.2 ± 0.1), which was attributed to the 1D packing structure of TES-pentacene compared to the 2D packing structure of TIPS-pentacene. This result was also supported by field-effect mobility anisotropy measurements of the films, with TES-pentacene exhibiting a higher anisotropy (∼21-47, depending on the casting speed) than TIPS-pentacene (∼3-10).
Monolithic focused reference beam X-ray holography
Geilhufe, J.; Pfau, B.; Schneider, M.; Büttner, F.; Günther, C. M.; Werner, S.; Schaffert, S.; Guehrs, E.; Frömmel, S.; Kläui, M.; Eisebitt, S.
2014-01-01
Fourier transform holography is a highly efficient and robust imaging method, suitable for single-shot imaging at coherent X-ray sources. In its common implementation, the image contrast is limited by the reference signal generated by a small pinhole aperture. Increased pinhole diameters improve the signal, whereas the resolution is diminished. Here we report a new concept to decouple the spatial resolution from the image contrast by employing a Fresnel zone plate to provide the reference beam. Superimposed on-axis images of distinct foci are separated with a novel algorithm. Our method is insensitive to mechanical drift or vibrations and allows for long integration times common at low-flux facilities like high harmonic generation sources. The application of monolithic focused reference beams improves the efficiency of high-resolution X-ray Fourier transform holography beyond all present approaches and paves the path towards sub-10 nm single-shot X-ray imaging. PMID:24394675
The Neural Network In Coordinate Transformation
NASA Astrophysics Data System (ADS)
Urusan, Ahmet Yucel
2011-12-01
In international literature, Coordinate operations is divided into two categories. They are coordinate conversion and coordinate transformation. Coordinates converted from coordinate system A to coordinate system B in the same datum (mean origine, scale and axis directions are same) by coordinate conversion. There are two different datum in coordinate transformation. The basis of each datum to a different coordinate reference system. In Coordinate transformation, coordinates are transformed from coordinate reference system A to coordinate referance system B. Geodetic studies based on physical measurements. Coordinate transformation needs identical points which were measured in each coordinate reference system (A and B). However it is difficult (and need a big reserved budget) to measure in some places like as top of mountain, boundry of countries and seaside. In this study, this sample problem solution was researched. The method of learning which is one of the neural network methods, was used for solution of this problem.
Mobile platform for treatment of stroke: A case study of tele-assistance.
Torres Zenteno, Arturo Henry; Fernández, Francisco; Palomino-García, Alfredo; Moniche, Francisco; Escudero, Irene; Jiménez-Hernández, M Dolores; Caballero, Auxiliadora; Escobar-Rodriguez, Germán; Parra, Carlos
2016-09-01
This article presents the technological solution of a tele-assistance process for stroke patients in acute phase in the Seville metropolitan area. The main objective of this process is to reduce time from symptom onset to treatment of acute phase stroke patients by means of telemedicine, regarding mobility between an intensive care unit ambulance and an expert center and activating the pre-hospital care phase. The technological platform covering the process has been defined following an interoperability model based on standards and with a focus on service-oriented architecture focus. Messaging definition has been designed according to the reference model of the CEN/ISO 13606, messages content follows the structure of archetypes. An XDS-b (Cross-Enterprise Document Sharing-b) transaction messaging has been designed according to Integrating the Healthcare Enterprise profile for archetype notifications and update enquiries.This research has been performed by a multidisciplinary group. The Virgen del Rocío University Hospital acts as Reference Hospital and the Public Company for Healthcare as mobility surroundings. © The Author(s) 2015.
2008-12-01
Figure 2. Definition of Attitude Angles and Torque Components in Spacecraft Reference Frame...Figure 5. PD controller in ideal three-axis-stabilized spacecraft ADCS. ................................16 Figure 6. Extract Position Angles function in...performance of spacecraft systems. Two categories of system architectures are discussed: recursive data management, found in feedback control systems; and
1952-03-01
to which astro - nomical latitudes and longitudes are referred. Moreover, the direction in space of the axis has a physical reality and maV be used for...product, or mixed product, or box product of three vectors i, U, E is the scalar V -i Bi~ F- iXiU.E - ’Exg . B - FXc i a- =1. .X F- F.x = .cx5 (EI-1) Z
Endocannabinoid Signaling and the Hypothalamic-Pituitary-Adrenal Axis.
Hillard, Cecilia J; Beatka, Margaret; Sarvaideo, Jenna
2016-12-06
The elucidation of Δ9-tetrahydrocannabinol as the active principal of Cannabis sativa in 1963 initiated a fruitful half-century of scientific discovery, culminating in the identification of the endocannabinoid signaling system, a previously unknown neuromodulatory system. A primary function of the endocannabinoid signaling system is to maintain or recover homeostasis following psychological and physiological threats. We provide a brief introduction to the endocannabinoid signaling system and its role in synaptic plasticity. The majority of the article is devoted to a summary of current knowledge regarding the role of endocannabinoid signaling as both a regulator of endocrine responses to stress and as an effector of glucocorticoid and corticotrophin-releasing hormone signaling in the brain. We summarize data demonstrating that cannabinoid receptor 1 (CB1R) signaling can both inhibit and potentiate the activation of the hypothalamic-pituitary-adrenal axis by stress. We present a hypothesis that the inhibitory arm has high endocannabinoid tone and also serves to enhance recovery to baseline following stress, while the potentiating arm is not tonically active but can be activated by exogenous agonists. We discuss recent findings that corticotropin-releasing hormone in the amygdala enables hypothalamic-pituitary-adrenal axis activation via an increase in the catabolism of the endocannabinoid N-arachidonylethanolamine. We review data supporting the hypotheses that CB1R activation is required for many glucocorticoid effects, particularly feedback inhibition of hypothalamic-pituitary-adrenal axis activation, and that glucocorticoids mobilize the endocannabinoid 2-arachidonoylglycerol. These features of endocannabinoid signaling make it a tantalizing therapeutic target for treatment of stress-related disorders but to date, this promise is largely unrealized. © 2017 American Physiological Society. Compr Physiol 7:1-15, 2017. Copyright © 2017 John Wiley & Sons, Inc.
Xie, Zuo-ping; Zhao, Bo-wen; Yuan, Hua; Hua, Qi-qi; Jin, She-hong; Shen, Xiao-yan; Han, Xin-hong; Zhou, Jia-mei; Fang, Min; Chen, Jin-hong
2013-01-01
Background: To establish the reference range of the angle between ascending aorta and main pulmonary artery of fetus in the second and third trimester using spatiotemporal image correlation (STIC), and to investigate the value of this angle in prenatal screening of conotruncal defects (CTDs). Materials and Methods: Volume images of 311 normal fetuses along with 20 fetuses with congenital heart diseases were recruited in this cross-sectional study. An offline analysis of acquired volume datasets was carried out with multiplanar mode. The angle between aorta and pulmonary artery was measured by navigating the pivot point and rotating axes and the reference range was established. The images of ascending aorta and main pulmonary artery in fetuses with congenital heart diseases were observed by rotating the axes within the normal angle reference range. Results: The angle between ascending aorta and main pulmonary artery of the normal fetus (range: 59.1˚~97.0˚, mean ± SD: 78.0˚ ± 9.7˚) was negatively correlated with gestational age (r = -0.52; p<0.01). By rotating the normal angle range corresponding to gestational age, the fetuses with CTD could not display views of their left ventricular long axis and main pulmonary trunk correctly. Conclusion: The left ventricular long axis and main pulmonary trunk views can be displayed using STIC so that the echocardiographic protocol of the cardiovascular joint could be standardized. The reference range of the angle between ascending aorta and main pulmonary artery is clinically useful in prenatal screening of CTD and provides a reliable quantitative standard to estimate the spatial relationship of the large arteries of fetus. PMID:24520485
A minimum drives automatic target definition procedure for multi-axis random control testing
NASA Astrophysics Data System (ADS)
Musella, Umberto; D'Elia, Giacomo; Carrella, Alex; Peeters, Bart; Mucchi, Emiliano; Marulo, Francesco; Guillaume, Patrick
2018-07-01
Multiple-Input Multiple-Output (MIMO) vibration control tests are able to closely replicate, via shakers excitation, the vibration environment that a structure needs to withstand during its operational life. This feature is fundamental to accurately verify the experienced stress state, and ultimately the fatigue life, of the tested structure. In case of MIMO random tests, the control target is a full reference Spectral Density Matrix in the frequency band of interest. The diagonal terms are the Power Spectral Densities (PSDs), representative for the acceleration operational levels, and the off-diagonal terms are the Cross Spectral Densities (CSDs). The specifications of random vibration tests are however often given in terms of PSDs only, coming from a legacy of single axis testing. Information about the CSDs is often missing. An accurate definition of the CSD profiles can further enhance the MIMO random testing practice, as these terms influence both the responses and the shaker's voltages (the so-called drives). The challenges are linked to the algebraic constraint that the full reference matrix must be positive semi-definite in the entire bandwidth, with no flexibility in modifying the given PSDs. This paper proposes a newly developed method that automatically provides the full reference matrix without modifying the PSDs, considered as test specifications. The innovative feature is the capability of minimizing the drives required to match the reference PSDs and, at the same time, to directly guarantee that the obtained full matrix is positive semi-definite. The drives minimization aims on one hand to reach the fixed test specifications without stressing the delicate excitation system; on the other hand it potentially allows to further increase the test levels. The detailed analytic derivation and implementation steps of the proposed method are followed by real-life testing considering different scenarios.
NASA Astrophysics Data System (ADS)
Kim, Y. T.; Lee, J. M.; Hwang, J. H.; Piao, J.; Woo, N. C.
2015-12-01
CO2 is one of the major causes for global climate change. Because stable carbon isotope ratio is used to trace carbon source, several analytical techniques likes IRMS (Isotope Ratio Mass Spectrometry) and LAS (Laser Absorption Spectrometry) were extensively used. Off-axis ICOS, a kind of LAS, has merits on long-term stability and field application, therefore it is widely being used in CCS (Carbon Capture and Storage) field. The aim of this study is to extend the application scope of OA-ICOS to determine dissolved inorganic carbon (DIC). Because OA-ICOS showed dependence of δ13C on CO2 concentration, data processing is required. We tested CO2 Carbon Isotope Analyzer (CCIA-36-EP, Los Gatos Research) with both reference gas (δ13C= -28.28‰) and aqueous solutions prepared by dissolving sodium bicarbonate standards (δ13C= -12.26‰ and +3.96‰). The differences of δ13C between reference and measurement values are plotted by CO2 concentrations, then compared. At first, we checked the similarity between our curve pattern for reference gas and Guillon's research (δ13C= -43.99‰) by other Analyzer. To analyze aqueous samples, more errors can be caused than gas analysis. The carbon isotope fractionation occurs during dissolving standard reagents and extracting DIC as CO2 gas form. This effect is mixed with CO2 concentration dependence effect, therefore the curve patterns are different with that for reference gas. Our experiments are done for various δ13C values. It could be an important point to use OA-ICOS to analyze DIC, too.
NASA Astrophysics Data System (ADS)
Sholihin; Susanti, Eka
2018-02-01
The development of increasingly advanced technology, make people want to be more developed and curiosity to know more to determine the development of advanced technology. Robot is a tool that can be used as a tool for people who have several advantages. Basically humanoid robot is a robot that resembles a human being with all the driving structure. In the application of this humanoid robot manufacture researchers use MPU6050 module which is an important component of the robot because it can provide a response to the angle reference axis X and Y reference axis, the reading corner still has noise if not filtered out beforehand. On the other hand the use of Complementary filters are the answer to reduce the noise. By arranging the filter coefficients and time sampling filter that affects the signal updates corner. The angle value will be the value of the sensor to the process to the PID system which generates output values that are integrated with the servo pulses. Researchers will test to get a reading of the most stable angle for this experiment is the "a" or the value of the filter coefficient = 0.96 and "dt" or the sampling time = 10 ms.
The Kinematics Parameters of the Galaxy Using Data of Modern Astrometric Catalogues
NASA Astrophysics Data System (ADS)
Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.
Based on the Ogorodnikov-Milne model, we analyze the proper motions of XPM2, UCAC4 and PPMXL stars. To estimate distances to the stars we used the method of statistical parallaxes herewith the random errors of the distance estimations do not exceed 10%. The method of statistical parallaxes was used to estimate the distances to stars with random errors no larger than 14%. The linear solar velocity relative to the local standard of rest, which is well determined for the local entroid (d 150 p), was used as a reference. We have established that the model component that describes the rotation of all stars under consideration about the Galactic Y axis differs from zero. For the distant (d < 1000 pc) PPMXL and UCAC4 stars, the mean rotation about the Galactic Y axis has been found to be M-13 = -0.75± 0.04 mas yr-1. As for distances greater than 1 kpc M-13>derived from the data of only XPM2 catalogue becomes positive and exceeds 0.5 mas yr-1. We interpret this rotation found using the distant stars as a residual rotation of the ICRS/Tycho-2 system relative to the inertial reference frame.