Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2017-07-01
With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
In Vitro Simulation and Validation of the Circulation with Congenital Heart Defects
Figliola, Richard S.; Giardini, Alessandro; Conover, Tim; Camp, Tiffany A.; Biglino, Giovanni; Chiulli, John; Hsia, Tain-Yen
2010-01-01
Despite the recent advances in computational modeling, experimental simulation of the circulation with congenital heart defect using mock flow circuits remains an important tool for device testing, and for detailing the probable flow consequences resulting from surgical and interventional corrections. Validated mock circuits can be applied to qualify the results from novel computational models. New mathematical tools, coupled with advanced clinical imaging methods, allow for improved assessment of experimental circuit performance relative to human function, as well as the potential for patient-specific adaptation. In this review, we address the development of three in vitro mock circuits specific for studies of congenital heart defects. Performance of an in vitro right heart circulation circuit through a series of verification and validation exercises is described, including correlations with animal studies, and quantifying the effects of circuit inertiance on test results. We present our experience in the design of mock circuits suitable for investigations of the characteristics of the Fontan circulation. We use one such mock circuit to evaluate the accuracy of Doppler predictions in the presence of aortic coarctation. PMID:21218147
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.
Donovan, F M
1975-01-01
A major problem in improving artificial heart designs is the absence of methods for accurate in vitro testing of artificial heart systems. A mock circulatory system has been constructed which hydraulically simulates the systemic and pulmonary circulations of the normal human. The device is constructed of 1/2 in. acrylic sheet and has overall dimensions of 24 in. wide, 16 in. tall, and 8 in. deep. The artificial heart to be tested is attached to the front of the device, and pumps fluid from the systemic venous chamber into the pulmonary arterial chamber and from the pulmonary venous chamber into the systemic arterial chamber. Each of the four chambers is hermetically sealed. The compliance of each chamber is determined by the volume of air trapped above the fluid in that chamber. The pulmonary and systemic resistances are set automatically by bellows-operated valves to simulate the barroreceptor response in the systemic arteries and the passive pulmonary resistance response in the pulmonary arteries. Cardiac output is measured by a turbine flowmeter in the systemic circulation. Results using the Kwan-Gett artificial heart show a good comparison between the mock circulatory system response and the calf response.
The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.
Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard
2017-10-01
Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.
Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J
2017-10-01
The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing.
Jansen-Park, So-Hyun; Hsu, Po-Lin; Müller, Indra; Steinseifer, Ulrich; Abel, Dirk; Autschbach, Rüdiger; Rossaint, Rolf; Schmitz-Rode, Thomas
2017-04-01
Mock heart circulation loops (MHCLs) serve as in-vitro platforms to investigate the physiological interaction between circulatory systems and cardiovascular devices. A mock heart (MH) engineered with silicone walls and helical aramid fibers, to mimic the complex contraction of a natural heart, has been developed to advance the MHCL previously developed in our group. A mock aorta with an anatomical shape enables the evaluation of a cannulation method for ventricular assist devices (VADs) and investigation of the usage of clinical measurement systems like pressure-volume catheters. Ventricle and aorta molds were produced based on MRI data and cast with silicone. Aramid fibers were layered in the silicone ventricle to reproduce ventricle torsion. A rotating hollow shaft was connected to the apex enabling the rotation of the MH and the connection of a VAD. Silicone wall thickness, aramid fiber angle and fiber pitch were varied to generate different MH models. All MH models were placed in a tank filled with variable amounts of water and air simulating the compliance. In this work, physiological ventricular torsion angles (15°-26°) and physiological pressure-volume loops were achieved. This MHCL can serve as a comprehensive testing platform for cardiovascular devices, such as artificial heart valves and cannulation of VADs.
Efficacy of bacteriophage therapy in a model of Burkholderia cenocepacia pulmonary infection
Carmody, Lisa A.; Gill, Jason J.; Summer, Elizabeth J.; Sajjan, Uma S.; Gonzalez, Carlos F.; Young, Ryland F.; LiPuma, John J.
2009-01-01
The therapeutic potential of bacteriophage (phage) in a mouse model of acute B. cenocepacia pulmonary infection was assessed. Phage were administered by either intranasal (i.n.) inhalation or intraperitoneal (i.p.) injection. Bacterial density, macrophage inflammatory protein-2 (MIP-2), and tumor necrosis factor-α (TNFα) levels were significantly reduced in lungs of mice treated with i.p. phage. No significant differences in lung bacterial density or MIP-2 levels were found between untreated mice and mice treated with i.n. phage, i.p. UV-inactivated phage, or i.p. λ phage controls. Mock-infected mice treated with phage showed no significant increase in lung MIP-2 or TNFα levels compared to mock-infected / mock-treated mice. We have demonstrated the efficacy of phage therapy in an acute B. cenocepacia lung infection model. Systemic administration of phage was more effective than inhalational administration, suggesting that circulating phage have better access to bacteria in lung compared to topical phage. PMID:20001604
Fereres, Alberto; Peñaflor, Maria Fernanda G. V.; Favaro, Carla F.; Azevedo, Kamila E. X.; Landi, Carolina H.; Maluta, Nathalie K. P.; Bento, José Mauricio S.; Lopes, Joao R.S.
2016-01-01
Virus infection frequently modifies plant phenotypes, leading to changes in behaviour and performance of their insect vectors in a way that transmission is enhanced, although this may not always be the case. Here, we investigated Bemisia tabaci response to tomato plants infected by Tomato chlorosis virus (ToCV), a non-circulative-transmitted crinivirus, and Tomato severe rugose virus (ToSRV), a circulative-transmitted begomovirus. Moreover, we examined the role of visual and olfactory cues in host plant selection by both viruliferous and non-viruliferous B. tabaci. Visual cues alone were assessed as targets for whitefly landing by placing leaves underneath a Plexiglas plate. A dual-choice arena was used to assess whitefly response to virus-infected and mock-inoculated tomato leaves under light and dark conditions. Thereafter, we tested the whitefly response to volatiles using an active air-flow Y-tube olfactometer, and chemically characterized the blends using gas chromatography coupled to mass spectrometry. Visual stimuli tests showed that whiteflies, irrespective of their infectious status, always preferred to land on virus-infected rather than on mock-inoculated leaves. Furthermore, whiteflies had no preference for either virus-infected or mock-inoculated leaves under dark conditions, but preferred virus-infected leaves in the presence of light. ToSRV-infection promoted a sharp decline in the concentration of some tomato volatiles, while an increase in the emission of some terpenes after ToCV infection was found. ToSRV-viruliferous whiteflies preferred volatiles emitted from mock-inoculated plants, a conducive behaviour to enhance virus spread, while volatiles from ToCV-infected plants were avoided by non-viruliferous whiteflies, a behaviour that is likely detrimental to the secondary spread of the virus. In conclusion, the circulative persistent begomovirus, ToSRV, seems to have evolved together with its vector B. tabaci to optimise its own spread. However, this type of virus-induced manipulation of vector behaviour was not observed for the semi persistent crinivirus, ToCV, which is not specifically transmitted by B. tabaci and has a much less intimate virus-vector relationship. PMID:27529271
Fereres, Alberto; Peñaflor, Maria Fernanda G V; Favaro, Carla F; Azevedo, Kamila E X; Landi, Carolina H; Maluta, Nathalie K P; Bento, José Mauricio S; Lopes, Joao R S
2016-08-11
Virus infection frequently modifies plant phenotypes, leading to changes in behaviour and performance of their insect vectors in a way that transmission is enhanced, although this may not always be the case. Here, we investigated Bemisia tabaci response to tomato plants infected by Tomato chlorosis virus (ToCV), a non-circulative-transmitted crinivirus, and Tomato severe rugose virus (ToSRV), a circulative-transmitted begomovirus. Moreover, we examined the role of visual and olfactory cues in host plant selection by both viruliferous and non-viruliferous B. tabaci. Visual cues alone were assessed as targets for whitefly landing by placing leaves underneath a Plexiglas plate. A dual-choice arena was used to assess whitefly response to virus-infected and mock-inoculated tomato leaves under light and dark conditions. Thereafter, we tested the whitefly response to volatiles using an active air-flow Y-tube olfactometer, and chemically characterized the blends using gas chromatography coupled to mass spectrometry. Visual stimuli tests showed that whiteflies, irrespective of their infectious status, always preferred to land on virus-infected rather than on mock-inoculated leaves. Furthermore, whiteflies had no preference for either virus-infected or mock-inoculated leaves under dark conditions, but preferred virus-infected leaves in the presence of light. ToSRV-infection promoted a sharp decline in the concentration of some tomato volatiles, while an increase in the emission of some terpenes after ToCV infection was found. ToSRV-viruliferous whiteflies preferred volatiles emitted from mock-inoculated plants, a conducive behaviour to enhance virus spread, while volatiles from ToCV-infected plants were avoided by non-viruliferous whiteflies, a behaviour that is likely detrimental to the secondary spread of the virus. In conclusion, the circulative persistent begomovirus, ToSRV, seems to have evolved together with its vector B. tabaci to optimise its own spread. However, this type of virus-induced manipulation of vector behaviour was not observed for the semi persistent crinivirus, ToCV, which is not specifically transmitted by B. tabaci and has a much less intimate virus-vector relationship.
Mueller, Indra; Jansen-Park, So-Hyun; Neidlin, Michael; Steinseifer, Ulrich; Abel, Dirk; Autschbach, Rüdiger; Rossaint, Rolf; Schmitz-Rode, Thomas; Sonntag, Simon Johannes
2017-04-01
Right heart failure (RHF), e.g. due to pulmonary hypertension (PH), is a serious health issue with growing occurrence and high mortality rate. Limited efficacy of medication in advanced stages of the disease constitutes the need for mechanical circulatory support of the right ventricle (RV). An essential contribution to the process of developing right ventricular assist devices (RVADs) is the in vitro test bench, which simulates the hemodynamic behavior of the native circulatory system. To model healthy and diseased arterial-pulmonary hemodynamics in adults (mild and severe PH and RHF), a right heart mock circulation loop (MCL) was developed. Incorporating an anatomically shaped silicone RV and a silicone atrium, it not only enables investigations of hemodynamic values but also suction events or the handling of minimal invasive RVADs in an anatomical test environment. Ventricular pressure-volume loops of all simulated conditions as well as pressure and volume waveforms were recorded and compared to literature data. In an exemplary test, an RVAD was connected to the apex to further test the feasibility of studying such devices with the developed MCL. In conclusion, the hemodynamic behavior of the native system was well reproduced by the developed MCL, which is a useful basis for future RVAD tests.
Fixation and mounting of porcine aortic valves for use in mock circuits.
Schlöglhofer, Thomas; Aigner, Philipp; Stoiber, Martin; Schima, Heinrich
2013-10-01
Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits. Porcine aortic roots were obtained from the abattoir and used either in native condition or after fixation. Fixation was performed at a constant retrograde pressure to ensure closed valve position. Fixation time was 4 h in a 0.5%-glutaraldehyde phosphate buffer. The fixed valves were molded into a modular mock circulation connector using a fast curing silicone. Valve functionality was evaluated in a pulsatile setting (cardiac output = 4.7 l/min, heart rate = 80 beats/min) and compared before and after fixation. Leaflet motion was recorded with a high-speed camera and valve insufficiency was quantified by leakage flow under steady pressure application (80 mmHg). Under physiological conditions the aortic valves showed almost equal leaflet motion in native and fixed conditions. However, the leaflets of the native valves showed lower stiffness and more fluttering during systole than the fixed specimens. Under retrograde pressure, fresh and fixed valves showed small leakage flows of <30 ml/min. The new mounting and fixation procedure is a fast method to fabricate low cost biologic valves for the use in mock circuits.
Vukicevic, M.; Chiulli, J.A.; Conover, T.; Pennati, G.; Hsia, T.Y.; Figliola, R.S.
2013-01-01
We describe an in vitro model of the Fontan circulation with respiration to study subdiaphragmatic venous flow behavior. The venous and arterial connections of a total cavopulmonary connection (TCPC) test section were coupled with a physical lumped parameter (LP) model of the circulation. Intrathoracic and subdiaphragmatic pressure changes associated with normal breathing were applied. This system was tuned for two patients (5 years, 0.67 m2; 10 years, 1.2 m2) to physiological values. System function was verified by comparison to the analytical model on which it was based and by consistency with published clinical measurements. Overall, subdiaphragmatic venous flow was influenced by respiration. Flow within the arteries and veins increased during inspiration but decreased during expiration with retrograde flow in the inferior venous territories. System pressures and flows showed close agreement with the analytical LP model (p < 0.05). The ratio of the flow rates occurring during inspiration to expiration were within the clinical range of values reported elsewhere. The approach used to setup and control the model was effective and provided reasonable comparisons with clinical data. PMID:23644612
An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.
Tozzi, Piergiorgio; Maertens, Audrey; Emery, Jonathan; Joseph, Samuel; Kirsch, Matthias; Avellan, François
2017-11-24
We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population. The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured. At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%. The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.
Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko
2010-03-01
We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.
System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.
Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero
2015-01-01
Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Physiological Characterization of the SynCardia Total Artificial Heart in a Mock Circulation System
Crosby, Jessica R.; DeCook, Katrina J.; Tran, Phat L.; Smith, Richard G.; Larson, Douglas F.; Khalpey, Zain I.; Burkhoff, Daniel; Slepian, Marvin J.
2014-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving bi-ventricular replacement system for a wide variety of patients with end-stage heart failure. While the clinical performance of the TAH is established, modern physiologic characterization, in terms of elastance behavior and pressure-volume characterization has not been defined. Herein we examine the TAH in terms of elastance using a non-ejecting left-ventricle, and then characterize the pressure-volume relationship of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Further, we show that the TAH has a pressure-volume relationship behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload, however this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared to the human heart. PMID:25551416
Physiological characterization of the SynCardia total artificial heart in a mock circulation system.
Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2015-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.
Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B
1997-01-01
An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.
Vukicevic, M; Conover, T; Jaeggli, M; Zhou, J; Pennati, G; Hsia, TY; Figliola, RS
2014-01-01
Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only while the valve leaflets were closed while cycle-averaged pressures improved only slightly (italic>1 mm Hg). Increased pulmonary vascular resistance raised mean circulation pressures but the valve functioned and cardiac output improved and stabilized. Power loss across the TCPC improved by 12–15% (pbold>0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance. PMID:24814833
Massive Air Embolism in a Fontan Patient
Matte, Gregory S.; Kussman, Barry D.; Wagner, Joseph W.; Boyle, Sharon L.; Howe, Robert J.; Pigula, Frank A.; Emani, Sitaram M.
2011-01-01
Abstract: Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit. PMID:21848177
Massive air embolism in a Fontan patient.
Matte, Gregory S; Kussman, Barry D; Wagner, Joseph W; Boyle, Sharon L; Howe, Robert J; Pigula, Frank A; Emani, Sitaram M
2011-06-01
Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit.
Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Hunt, Elizabeth A; Walker, Allen R; Shaffner, Donald H; Miller, Marlene R; Pronovost, Peter J
2008-01-01
Outcomes of in-hospital pediatric cardiopulmonary arrest are dismal. Recent data suggest that the quality of basic and advanced life support delivered to adults is low and contributes to poor outcomes, but few data regarding pediatric events have been reported. The objectives of this study were to (1) measure the median elapsed time to initiate important resuscitation maneuvers in simulated pediatric medical emergencies (ie, "mock codes") and (2) identify the types and frequency of errors committed during pediatric mock codes. A prospective, observational study was conducted of 34 consecutive hospital-based mock codes. A mannequin or computerized simulator was used to enact unannounced, simulated crisis situations involving children with respiratory distress or insufficiency, respiratory arrest, hemodynamic instability, and/or cardiopulmonary arrest. Assessment included time elapsed to initiation of specific resuscitation maneuvers and deviation from American Heart Association guidelines. Among the 34 mock codes, the median time to assessment of airway and breathing was 1.3 minutes, to administration of oxygen was 2.0 minutes, to assessment of circulation was 4.0 minutes, to arrival of any physician was 3.0 minutes, and to arrival of first member of code team was 6.0 minutes. Among cardiopulmonary arrest scenarios, elapsed time to initiation of compressions was 1.5 minutes and to request for defibrillator was 4.3 minutes. In 75% of mock codes, the team deviated from American Heart Association pediatric basic life support protocols, and in 100% of mock codes there was a communication error. Alarming delays and deviations occur in the major components of pediatric resuscitation. Future educational and organizational interventions should focus on improving the quality of care delivered during the first 5 minutes of resuscitation. Simulation of pediatric crises can identify targets for educational intervention to improve pediatric cardiopulmonary resuscitation and, ideally, outcomes.
Design guidelines for robotically serviceable hardware
NASA Technical Reports Server (NTRS)
Gordon, Scott A.
1988-01-01
Research being conducted at the Goddard Space Flight Center into the development of guidelines for the design of robotically serviceable spaceflight hardware is described. A mock-up was built based on an existing spaceflight system demonstrating how these guidelines can be applied to actual hardware. The report examines the basic servicing philosophy being studied and how this philosophy is reflected in the formulation of design guidelines for robotic servicing. A description of the mock-up is presented with emphasis on the design features that make it robot friendly. Three robotic servicing schemes fulfilling the design guidelines were developed for the mock-up. These servicing schemes are examined as to how their implementation was affected by the constraints of the spacecraft system on which the mock-up is based.
The Rhetoric of Mock Trial Debate: Using Logos, Pathos and Ethos in Undergraduate Competition
ERIC Educational Resources Information Center
Walker, Felicia R.
2005-01-01
While engaging in learning about roles of evidence, rules of procedure and case law, undergraduate mock trial students must also learn how to effectively communicate their evidence to the fact-finder. In mock trial, as in real courtroom trials in the United States legal system, communication skills and the ability to persuade are essential. This…
Evaluation of a mock interview session on residency interview skills.
Buckley, Kelsey; Karr, Samantha; Nisly, Sarah A; Kelley, Kristi
2018-04-01
To evaluate the impact of student pharmacist participation in a mock interview session on confidence level and preparation regarding residency interview skills. The study setting was a mock interview session, held in conjunction with student programming at the American College of Clinical Pharmacy (ACCP) Annual Meeting. Prior to the mock interview session, final year student pharmacists seeking residency program placement were asked to complete a pre-session survey assessing confidence level for residency interviews. Each student pharmacist participated in up to three mock interviews. A post-session survey evaluating confidence level was then administered to consenting participants. Following the American Society for Health-System Pharmacists (ASHP) Pharmacy Resident Matching Program (RMP), a post-match electronic survey was sent to study participants to determine their perception of the influence of the mock interview session on achieving successful interactions during residency interviews. A total of 59 student pharmacists participated in the mock interview session and completed the pre-session survey. Participants completing the post-session survey (88%, n = 52) unanimously reported an enhanced confidence in interviewing skills following the session. Thirty responders reported a program match rate of 83%. Approximately 97% (n = 29) of the respondents agreed or strongly agreed that the questions asked during the mock interview session were reflective of questions asked during residency interviews. Lessons learned from this mock interview session can be applied to PGY1 residency mock interview sessions held locally, regionally, and nationally. Students participating in the ACCP Mock Interview Session recognized the importance of the interview component in obtaining a postgraduate year 1 (PGY1) pharmacy residency. Copyright © 2017 Elsevier Inc. All rights reserved.
A faculty-led mock residency interview exercise for fourth-year doctor of pharmacy students.
Koenigsfeld, Carrie F; Wall, Geoffrey C; Miesner, Andrew R; Schmidt, Ginelle; Haack, Sally L; Eastman, Darla K; Grady, Sarah; Fornoff, Anisa
2012-02-01
To determine whether a faculty-led mock-interview activity enhanced pharmacy student preparation for the residency interview process and increased match rates. Twenty-eight doctor of pharmacy students volunteered for a 40-minute mock-interview session with 2-person faculty teams. A standard roster of 12 interview questions was derived from published literature and the faculty members' experience. Feedback on the student's interview performance was provided verbally during the session. Following the interview, students were given a 2-part survey instrument. The first part of the survey was administered immediately following the mock-interview session and the second part was administered after the standard date for residency program results (known as "Match Day"). Participant match rates were compared to American Society of Health-System Pharmacists (ASHP) national rates. 82.5% (23 of 27) of students in the mock-interview group matched a postgraduate year 1 (PGY1) program. Compared to national rates (61.9%), more students in our surveyed mock-interview group matched a PGY1 residency (P = .015; odds ratio [OR] 3.546, 95% CI 1.161-12.116). Higher match rates were seen in the students completing the mock residency interview compared to ASHP national rates. In general, students completing the mock interview found the process helpful and felt better prepared for their residency interviews.
ERIC Educational Resources Information Center
Henderson, Kamina A.; Roe, Richard L.
This packet of materials contains law-related materials for students to conduct a mock trial. In this case a faulty water system, containing the parasite Pindia, contributed to the death of an AIDS patient. Statements from the plaintiff, a representative of the Metro City Water Department, health officials, and others are presented. New releases,…
Takahashi, K; Kajiwara, K; Oda, Y; Kasugai, A; Kobayashi, N; Sakamoto, K; Doane, J; Olstad, R; Henderson, M
2011-06-01
High power, long pulse millimeter (mm) wave experiments of the RF test stand (RFTS) of Japan Atomic Energy Agency (JAEA) were performed. The system consists of a 1 MW/170 GHz gyrotron, a long and short distance transmission line (TL), and an equatorial launcher (EL) mock-up. The RFTS has an ITER-relevant configuration, i.e., consisted by a 1 MW-170 GHz gyrotron, a mm wave TL, and an EL mock-up. The TL is composed of a matching optics unit, evacuated circular corrugated waveguides, 6-miter bends, an in-line waveguide switch, and an isolation valve. The EL-mock-up is fabricated according to the current design of the ITER launcher. The Gaussian-like beam radiation with the steering capability of 20°-40° from the EL mock-up was also successfully proved. The high power, long pulse power transmission test was conducted with the metallic load replaced by the EL mock-up, and the transmission of 1 MW/800 s and 0.5 MW/1000 s was successfully demonstrated with no arcing and no damages. The transmission efficiency of the TL was 96%. The results prove the feasibility of the ITER electron cyclotron heating and current drive system. © 2011 American Institute of Physics
Visualization of the contact line during the water exit of flat plates
NASA Astrophysics Data System (ADS)
Tassin, A.; Breton, T.; Forest, B.; Ohana, J.; Chalony, S.; Le Roux, D.; Tancray, A.
2017-08-01
We investigate experimentally the time evolution of the wetted surface during the lifting of a body initially floating at the water surface. This phenomenon is referred to as the water exit problem. The water exit experiments were conducted with transparent (PMMA) mock-ups of two different shapes: a circular disc and a square flat plate. Two different lighting systems were used to diffuse light in the mock-up material: a central high-power LED light normal to the surface and an edge-lighting system featuring an array of LED lights. These setups make it possible to illuminate the contact line, which delimits the surface of contact between the mock-up and the water. The characteristic size of the mock-ups is about 20 cm and the acceleration of the mock-up oscillates between 0 and 25 m/s^2. We show that the central light setup gives satisfactory results for the circular disc and that the edge lighting technique makes it possible to follow a contact line with a time-evolving complex shape (strong changes of convexity) up to 1000 fps. The observations presented in the paper support the possibility of extending this promising technique to more general three-dimensional bodies with arbitrary motion (e.g., including pitch motion).
Study of Cycling Air-Cooling System with a Cold Accumulator for Micro Gas-Turbine Installations
NASA Astrophysics Data System (ADS)
Ochkov, V. F.; Stepanova, T. A.; Katenev, G. M.; Tumanovskii, V. A.; Borisova, P. N.
2018-05-01
Using the cycling air-cooling systems of the CTIC type (Combustion Turbine Inlet Cooling) with a cold accumulator in a micro gas-turbine installation (micro-GTI) to preserve its capacity under the seasonal temperature rise of outside air is described. Water ice is used as the body-storage in the accumulators, and ice water (water at 0.5-1.0°C) is used as the body that cools air. The ice water circulates between the accumulator and the air-water heat exchanger. The cold accumulator model with renewable ice resources is considered. The model contains the heat-exchanging tube lattice-evaporator covered with ice. The lattice is cross-flowed with water. The criterion heat exchange equation that describes the process in the cold accumulator under consideration is presented. The calculations of duration of its active operation were performed. The dependence of cold accumulator service life on water circulation rate was evaluated. The adequacy of the design model was confirmed experimentally in the mock-up of the cold accumulator with a refrigerating machine periodically creating a 200 kg ice reserve in the reservoir-storage. The design model makes it possible to determine the weight of ice reserve of the discharged cold accumulator for cooling the cycle air in the operation of a C-30 type micro- GTI produced by the Capstone Company or micro-GTIs of other capacities. Recommendations for increasing the working capacity of cold accumulators of CTIC-systems of a micro-GTI were made.
Autonomous identification of matrices in the APNea system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hensley, D.
1995-12-31
The APNea System is a passive and active neutron assay device which features imaging to correct for nonuniform distributions of source material. Since the imaging procedure requires a detailed knowledge of both the detection efficiency and the thermal neutron flux for (sub)volumes of the drum of interest, it is necessary to identify which mocked-up matrix, to be used for detailed characterization studies, best matches the matrix of interest. A methodology referred to as the external matrix probe (EMP) has been established which links external measures of a drum matrix to those of mocked-up matrices. These measures by themselves are sufficientmore » to identify the appropriate mock matrix, from which the necessary characterization data are obtained. This independent matrix identification leads to an autonomous determination of the required system response parameters for the assay analysis.« less
Autonomous identification of matrices in the APNea System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hensley, D.
1995-12-31
The APNea System is a passive and active neutron assay device which features imaging to correct for nonuniform distributions of source material. Since the imaging procedure requires a detailed knowledge of both the detection efficiency and the thermal neutron flux for (sub)volumes of the drum of interest, it is necessary to identify which mocked-up matrix, to be used for detailed characterization studies, best matches the matrix of interest. A methodology referred to as the external matrix probe (EMP) has been established which links external measures of a drum matrix to those of mocked-up matrices. These measures by themselves are sufficientmore » to identify the appropriate mock matrix, from which the necessary characterization data are obtained. This independent matrix identification leads to an autonomous determination of the required system response parameters for the assay analysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krichinsky, Alan M; Bates, Bruce E; Chesser, Joel B
2009-12-01
This report describes an engineering-scale, mock UF6 feed and withdrawal (F&W) system, its operation, and its intended uses. This system has been assembled to provide a test bed for evaluating and demonstrating new methodologies that can be used in remote, unattended, continuous monitoring of nuclear material process operations. These measures are being investigated to provide independent inspectors improved assurance that operations are being conducted within declared parameters, and to increase the overall effectiveness of safeguarding nuclear material. Testing applicable technologies on a mock F&W system, which uses water as a surrogate for UF6, enables thorough and cost-effective investigation of hardware,more » software, and operational strategies before their direct installation in an industrial nuclear material processing environment. Electronic scales used for continuous load-cell monitoring also are described as part of the basic mock F&W system description. Continuous monitoring components on the mock F&W system are linked to a data aggregation computer by a local network, which also is depicted. Data collection and storage systems are described only briefly in this report. The mock UF{sub 6} F&W system is economical to operate. It uses a simple process involving only a surge tank between feed tanks and product and withdrawal (or waste) tanks. The system uses water as the transfer fluid, thereby avoiding the use of hazardous UF{sub 6}. The system is not tethered to an operating industrial process involving nuclear materials, thereby allowing scenarios (e.g., material diversion) that cannot be conducted otherwise. These features facilitate conducting experiments that yield meaningful results with a minimum of expenditure and quick turnaround time. Technologies demonstrated on the engineering-scale system lead to field trials (described briefly in this report) for determining implementation issues and performance of the monitoring technologies under plant operating conditions. The ultimate use of technologies tested on the engineering-scale test bed is to work with safeguards agencies to install them in operating plants (e.g., enrichment and fuel processing plants), thereby promoting new safeguards measures with minimal impact to operating plants. In addition, this system is useful in identifying features for new plants that can be incorporated as part of 'safeguards by design,' in which load cells and other monitoring technologies are specified to provide outputs for automated monitoring and inspector evaluation.« less
Mock Trials: Scripts for Wisconsin Lawyers and Teachers.
ERIC Educational Resources Information Center
Wisconsin State Dept. of Public Instruction, Madison. Div. of Instructional Services.
The document presents scripts prepared by experienced lawyers for seven mock trials. Designed for high school or adult audiences as introductions to the American legal system, the scripts use community lawyers, judges, and law officers as well as actors. Script topics include cases concerning automobile accidents, drunken driving, homicide,…
Knoops, Paul G M; Biglino, Giovanni; Hughes, Alun D; Parker, Kim H; Xu, Linzhang; Schievano, Silvia; Torii, Ryo
2017-07-01
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an anatomically representative arterial model suitable for testing clinically relevant scenarios. A second objective of the study was to ensure the system's compatibility with magnetic resonance imaging (MRI) for additional measurements. A latex pulmonary arterial model with two generations of bifurcations was manufactured starting from a 3D-printed mold reconstructed from patient data. The model was incorporated into a MCS for in vitro hydrodynamic measurements. The setup was tested under physiological pulsatile flow conditions and results were evaluated using wave intensity analysis (WIA) to investigate waves traveling in the arterial system. Increased pulmonary vascular resistance (IPVR) was simulated as an example of one pathological scenario. Flow split between right and left pulmonary artery was found to be realistic (54 and 46%, respectively). No substantial difference in pressure waveform was observed throughout the various generations of bifurcations. Based on WIA, three main waves were identified in the main pulmonary artery (MPA), that is, forward compression wave, backward compression wave, and forward expansion wave. For IPVR, a rise in mean pressure was recorded in the MPA, within the clinical range of pulmonary arterial hypertension. The feasibility of using the MCS in the MRI scanner was demonstrated with the MCS running 2 h consecutively while acquiring preliminary MRI data. This study shows the development and verification of a pulmonary MCS, including an anatomically correct, compliant latex phantom. The setup can be useful to explore a wide range of hemodynamic questions, including the development of patient- and pathology-specific models, considering the ease and low cost of producing rapid prototyping molds, and the versatility of the setup for invasive and noninvasive (i.e., MRI) measurements. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Knoops, Paul G.M.; Biglino, Giovanni; Hughes, Alun D.; Parker, Kim H.; Xu, Linzhang; Schievano, Silvia; Torii, Ryo
2017-01-01
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an anatomically representative arterial model suitable for testing clinically relevant scenarios. A second objective of the study was to ensure the system's compatibility with magnetic resonance imaging (MRI) for additional measurements. A latex pulmonary arterial model with two generations of bifurcations was manufactured starting from a 3D-printed mold reconstructed from patient data. The model was incorporated into a MCS for in vitro hydrodynamic measurements. The setup was tested under physiological pulsatile flow conditions and results were evaluated using wave intensity analysis (WIA) to investigate waves traveling in the arterial system. Increased pulmonary vascular resistance (IPVR) was simulated as an example of one pathological scenario. Flow split between right and left pulmonary artery was found to be realistic (54 and 46%, respectively). No substantial difference in pressure waveform was observed throughout the various generations of bifurcations. Based on WIA, three main waves were identified in the main pulmonary artery (MPA), that is, forward compression wave, backward compression wave, and forward expansion wave. For IPVR, a rise in mean pressure was recorded in the MPA, within the clinical range of pulmonary arterial hypertension. The feasibility of using the MCS in the MRI scanner was demonstrated with the MCS running 2 h consecutively while acquiring preliminary MRI data. This study shows the development and verification of a pulmonary MCS, including an anatomically correct, compliant latex phantom. The setup can be useful to explore a wide range of hemodynamic questions, including the development of patient- and pathology-specific models, considering the ease and low cost of producing rapid prototyping molds, and the versatility of the setup for invasive and noninvasive (i.e., MRI) measurements. PMID:27925228
State of Oklahoma v. Tracy Smith. 1999-2000 Oklahoma High School Mock Trial Program.
ERIC Educational Resources Information Center
Stucky, Melanie; Eberle, April; Cale, Stephen
This mock trial curriculum is intended to help high school students learn about the law and the legal system. The curriculum is divided into the following sections: Statement of the Case, Stipulations, Legal Authorities, Witness Statements/Narrative Report (Prosecution Witnesses; Defense Witnesses), and Exhibits (Statement of Miranda Rights; Front…
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
Biglino, Giovanni; Kolyva, Christina; Khir, Ashraf W
2012-01-01
Despite decades of successful clinical use of the intra aortic balloon pump (IABP), certain aspects of its operation are not yet fully understood. This work aims to investigate in vitro the mechanism underlying balloon inflation and deflation with varying assisting frequency and operating angle with respect to the horizontal, by studying the corresponding pressure and wave energy changes. A mock circulatory system (MCS), with physiological distribution of peripheral resistance and compliance, presented a controllable test bed. We used Wave Intensity Analysis (WIA) to identify balloon-generated waves and quantify their energy. Conventional hemodynamic parameters were also calculated. Tests were repeated at varying operating angles (0°-45°), resembling the semi-recumbent position in the ICU, and at different assisting frequencies (1:1, 1:2, 1:3). Two balloons (25 cc and 40 cc in volume) were tested. The main waves associated with counterpulsation were identified as a backward compression wave associated with balloon inflation and a backward expansion wave associated with balloon deflation. Results showed that the IABP inflation and deflation benefits are reduced with increasing angle, in terms of the size of the inflation and deflation waves as well as in terms of diastolic pressure augmentation and end-diastolic pressure reduction. Both WIA findings and pressure parameters indicated 1:1 as the most effective mode of pumping. This study shows that, in vitro, a greater benefit of counterpulsation can be achieved in the horizontal position at 1:1 assisting frequency, with a good correlation between wave and pressure results.
The influence of sex on mock jurors' verdicts across type of child abuse cases.
Pettalia, Jennifer; Pozzulo, Joanna D; Reed, Jennifer
2017-07-01
This study examined the influence of victim sex, mock juror sex, and type of child abuse (physical, sexual, emotional, and neglect) on mock jurors' assessments of eyewitness and defendant integrity, continuous guilt ratings, dichotomous verdicts, and sentencing recommendations. Participants read one of eight versions of a trial transcript and then answered a self-report questionnaire. Female mock jurors were significantly more likely to find the defendant guilty overall. Moreover, female mock jurors recommended significantly longer sentences for defendants in sexual abuse cases; whereas, male mock jurors recommended significantly longer sentences for defendants in sexual and physical abuse cases. Male mock jurors perceived the defendant more favorably than female mock jurors; whereas, female mock jurors perceived the alleged victim more favorable than male mock jurors. These results suggest that juror sex may be an influential factor in child abuse cases overall. Copyright © 2017 Elsevier Ltd. All rights reserved.
Developmental nephrotoxicity of aristolochic acid in a zebrafish model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Yu-Ju; Chen, Yau-Hung, E-mail: yauhung@mail.tku.edu.tw
2012-05-15
Aristolochic acid (AA) is a component of Aristolochia plant extracts which is used as a treatment for different pathologies and their toxicological effects have not been sufficiently studied. The aim of this study was to evaluate AA-induced nephrotoxicity in zebrafish embryos. After soaking zebrafish embryos in AA, the embryos displayed malformed kidney phenotypes, such as curved, cystic pronephric tubes, pronephric ducts, and cases of atrophic glomeruli. The percentages of embryos with malformed kidney phenotypes increased as the exposure dosages of AA increased. Furthermore, AA-treated embryos exhibited significantly reduced glomerular filtration rates (GFRs) in comparison with mock-control littermates (mock-control: 100 ±more » 2.24% vs. 10 ppm AA treatment for 3–5 h: 71.48 ± 18.84% ∼ 39.41 ± 15.88%), indicating that AA treatment not only caused morphological kidney changes but also induced renal failure. In addition to kidney malformations, AA-treated zebrafish embryos also exhibited deformed hearts, swollen pericardiums, impaired blood circulation and the accumulation(s) of red blood cells. Whole-mount in situ hybridization studies using cmlc2 and wt1b as riboprobes indicated that the kidney is more sensitive than the heart to AA damage. Real-time PCR showed that AA can up-regulate the expression of proinflammatory genes like TNFα, cox2 and mpo. These results support the following conclusions: (1) AA-induced renal failure is mediated by inflammation, which causes circulation dysfunction followed by serious heart malformation; and (2) the kidney is more sensitive than the heart to AA injury. -- Highlights: ► Zebrafish were used to evaluate aristolochic acid (AA)-induced nephrotoxicity. ► AA-treated zebrafish embryos exhibited deformed heart as well as malformed kidney. ► Kidney is more sensitive to AA injury than the heart.« less
Advanced Spacesuit Portable Life Support System Packaging Concept Mock-Up Design & Development
NASA Technical Reports Server (NTRS)
O''Connell, Mary K.; Slade, Howard G.; Stinson, Richard G.
1998-01-01
A concentrated development effort was begun at NASA Johnson Space Center to create an advanced Portable Life Support System (PLSS) packaging concept. Ease of maintenance, technological flexibility, low weight, and minimal volume are targeted in the design of future micro-gravity and planetary PLSS configurations. Three main design concepts emerged from conceptual design techniques and were carried forth into detailed design, then full scale mock-up creation. "Foam", "Motherboard", and "LEGOtm" packaging design concepts are described in detail. Results of the evaluation process targeted maintenance, robustness, mass properties, and flexibility as key aspects to a new PLSS packaging configuration. The various design tools used to evolve concepts into high fidelity mock ups revealed that no single tool was all encompassing, several combinations were complimentary, the devil is in the details, and, despite efforts, many lessons were learned only after working with hardware.
Flowpath evaluation and reconnaissance by remote field Eddy current testing (FERRET)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smoak, A.E.; Zollinger, W.T.
1993-12-31
This document describes the design and development of FERRET (Flowpath Evaluation and Reconnaisance by Remote-field Eddy current Testing). FERRET is a system for inspecting the steel pipes which carry cooling water to underground nuclear waste storage tanks. The FERRET system has been tested in a small scale cooling pipe mock-up, an improved full scale mock-up, and in flaw detection experiments. Early prototype designs of FERRET and the FERRET launcher (a device which inserts, moves, and retrieves probes from a piping system) as well as the field-ready design are discussed.
Initial in vitro testing of a paediatric continuous-flow total artificial heart.
Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader
2018-06-01
Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
Computerized Biomechanical Man-Model
1976-07-01
Force Systems Command Wright-Patterson AFB, Ohio ABSTRACT The COMputerized BIomechanical MAN-Model (called COMBIMAN) is a computer interactive graphics...concept was to build a mock- The use of mock-ups for biomechanical evalua- up which permitted the designer to visualize the tion has long been a tool...of the can become an obstacle to design change. Aerospace Medical Research Laboratory, we are developing a computerized biomechanical man-model
Kumazaki, Hirokazu; Warren, Zachary; Corbett, Blythe A.; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Higashida, Haruhiro; Yuhi, Teruko; Ikeda, Takashi; Ishiguro, Hiroshi; Kikuchi, Mitsuru
2017-01-01
The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18–25 years) with autism spectrum disorder (ASD) were randomized to participate either in a mock job interview training with our android robot system (n = 7) or a self-paced review of materials about job-interviewing skills (n = 8). Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning. PMID:28955254
Kumazaki, Hirokazu; Warren, Zachary; Corbett, Blythe A; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Higashida, Haruhiro; Yuhi, Teruko; Ikeda, Takashi; Ishiguro, Hiroshi; Kikuchi, Mitsuru
2017-01-01
The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18-25 years) with autism spectrum disorder (ASD) were randomized to participate either in a mock job interview training with our android robot system ( n = 7) or a self-paced review of materials about job-interviewing skills ( n = 8). Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning.
NASA Technical Reports Server (NTRS)
Schifer, Nicholas A.; Briggs, Maxwell H.
2012-01-01
The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a specified electrical power output for a given net heat input. While electrical power output can be precisely quantified, thermal power input to the Stirling cycle cannot be directly measured. In an effort to improve net heat input predictions, the Mock Heater Head was developed with the same relative thermal paths as a convertor using a conducting rod to represent the Stirling cycle and tested to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. The Mock Heater Head also served as the pathfinder for a higher fidelity version of validation test hardware, known as the Thermal Standard. This paper describes how the Mock Heater Head was tested and utilized to validate a process for the Thermal Standard.
Latent infection by γherpesvirus stimulates profibrotic mediator release from multiple cell types.
Stoolman, Joshua S; Vannella, Kevin M; Coomes, Stephanie M; Wilke, Carol A; Sisson, Thomas H; Toews, Galen B; Moore, Bethany B
2011-02-01
Although γherpesvirus infections are associated with enhanced lung fibrosis in both clinical and animal studies, there is limited understanding about fibrotic effects of γherpesviruses on cell types present in the lung, particularly during latent infection. Wild-type mice were intranasally infected with a murine γherpesvirus (γHV-68) or mock-infected with saline. Twenty-eight days postinfection (dpi), ∼14 days following clearance of the lytic infection, alveolar macrophages (AMs), mesenchymal cells, and CD19-enriched cell populations from the lung and spleen express M(3) and/or glycoprotein B (gB) viral mRNA and harbor viral genome. AMs from infected mice express more transforming growth factor (TGF)-β(1), CCL2, CCL12, TNF-α, and IFN-γ than AMs from mock-infected mice. Mesenchymal cells express more total TGF-β(1), CCL12, and TNF-α than mesenchymal cells from mock-infected mice. Lung and spleen CD19-enriched cells express more total TGF-β(1) 28 dpi compared with controls. The CD19-negative fraction of the spleen overexpresses TGF-β(1) and harbors viral genome, but this likely represents infection of monocytes. Purified T cells from the lung harbor almost no viral genome. Purified T cells overexpress IL-10 but not TGF-β(1). Intracellular cytokine staining demonstrated that lung T cells at 28 dpi produce IFN-γ but not IL-4. Thus infection with a murine γherpesvirus is sufficient to upregulate profibrotic and proinflammatory factors in a variety of lung resident and circulating cell types 28 dpi. Our results provide new information about possible contributions of these cells to fibrogenesis in the lungs of individuals harboring a γherpesvirus infection and may help explain why γHV-68 infection can augment or exacerbate fibrotic responses in mice.
In Vitro Study of Flow Regulation for Pulmonary Insufficiency
Camp, T. A.; Stewart, K. C.; Figliola, R. S.; McQuinn, T.
2007-01-01
Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device. PMID:17408334
Parallel Execution of Functional Mock-up Units in Buildings Modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozmen, Ozgur; Nutaro, James J.; New, Joshua Ryan
2016-06-30
A Functional Mock-up Interface (FMI) defines a standardized interface to be used in computer simulations to develop complex cyber-physical systems. FMI implementation by a software modeling tool enables the creation of a simulation model that can be interconnected, or the creation of a software library called a Functional Mock-up Unit (FMU). This report describes an FMU wrapper implementation that imports FMUs into a C++ environment and uses an Euler solver that executes FMUs in parallel using Open Multi-Processing (OpenMP). The purpose of this report is to elucidate the runtime performance of the solver when a multi-component system is imported asmore » a single FMU (for the whole system) or as multiple FMUs (for different groups of components as sub-systems). This performance comparison is conducted using two test cases: (1) a simple, multi-tank problem; and (2) a more realistic use case based on the Modelica Buildings Library. In both test cases, the performance gains are promising when each FMU consists of a large number of states and state events that are wrapped in a single FMU. Load balancing is demonstrated to be a critical factor in speeding up parallel execution of multiple FMUs.« less
Defendant remorse, need for affect, and juror sentencing decisions.
Corwin, Emily P; Cramer, Robert J; Griffin, Desiree A; Brodsky, Stanley L
2012-01-01
Defendant remorse is generally accepted as a mitigating factor in capital murder sentencing in the legal system. The current study addressed whether verbal and nonverbal expressions of defendant remorse are perceived as remorseful by mock jurors. Moreover, this study investigated the associations of defendant behaviors and mock juror need for affect on sentencing decisions. Participants watched a video of a defendant depicting either high or low levels of verbal and nonverbal remorseful behavior. Results indicated that nonverbal behaviors were more important than verbal cues for perception of remorse. Incongruent verbal and nonverbal behavior, as well as mock juror willingness to approach emotional situations (i.e., high need for affect (NFA)) resulted in more lenient sentences for defendants. Implications for the remorse construct, for witness preparation, and for jury selection are discussed.
Colacino, Francesco Maria; Moscato, Francesco; Piedimonte, Fabio; Danieli, Guido; Nicosia, Salvatore; Arabia, Maurizio
2008-01-01
This article describes an elastance-based mock ventricle able to reproduce the correct ventricular pressure-volume relationship and its correct interaction with the hydraulic circuit connected to it. A real-time control of the mock ventricle was obtained by a new left ventricular mathematical model including resistive and inductive terms added to the classical Suga-Sagawa elastance model throughout the whole cardiac cycle. A valved piston pump was used to mimic the left ventricle. The pressure measured into the pump chamber was fed back into the mathematical model and the calculated reference left ventricular volume was used to drive the piston. Results show that the classical model is very sensitive to pressure disturbances, especially during the filling phase, while the modified model is able to filter out the oscillations thus eliminating their detrimental effects. The presented model is thus suitable to control mock ventricles in real-time, where sudden pressure disturbances represent a key issue and are not negligible. This real-time controlled mock ventricle is able to reproduce the elastance mechanism of a natural ventricle by mimicking its preload (mean atrial pressure) and afterload (mean aortic pressure) sensitivity, i.e., the Starling law. Therefore, it can be used for designing and testing cardiovascular prostheses due to its capability to reproduce the correct ventricle-vascular system interaction.
Sam, Jonathan; Pierse, Michael; Al-Qahtani, Abdullah; Cheng, Adam
2012-02-01
To develop, implement and evaluate a simulation-based acute care curriculum in a paediatric residency program using an integrated and longitudinal approach. Curriculum framework consisting of three modular, year-specific courses and longitudinal just-in-time, in situ mock codes. Paediatric residency program at BC Children's Hospital, Vancouver, British Columbia. The three year-specific courses focused on the critical first 5 min, complex medical management and crisis resource management, respectively. The just-in-time in situ mock codes simulated the acute deterioration of an existing ward patient, prepared the actual multidisciplinary code team, and primed the surrounding crisis support systems. Each curriculum component was evaluated with surveys using a five-point Likert scale. A total of 40 resident surveys were completed after each of the modular courses, and an additional 28 surveys were completed for the overall simulation curriculum. The highest Likert scores were for hands-on skill stations, immersive simulation environment and crisis resource management teaching. Survey results also suggested that just-in-time mock codes were realistic, reinforced learning, and prepared ward teams for patient deterioration. A simulation-based acute care curriculum was successfully integrated into a paediatric residency program. It provides a model for integrating simulation-based learning into other training programs, as well as a model for any hospital that wishes to improve paediatric resuscitation outcomes using just-in-time in situ mock codes.
Bibliography of Mock Trial Materials.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
This catalog lists general articles on mock trials, information for arranging mock trial competitions, mock trial problem sets, and video tapes. The problem sets contain introductory material, applicable law, statements of facts, witness statements, and documents. The cases include issues in family, consumer, criminal, and immigration law. Several…
Using Controversial Mock Trials in "Psychology and Law" Courses: Suggestions from Participants.
ERIC Educational Resources Information Center
Werth, James L., Jr.; Harvey, James; McNamara, Rebecca; Svoboda, Andrea; Gulbrandson, Raina; Hendren, Jennifer; Greedy, Tiffany; Leybold, Christie
2002-01-01
Describes a mock trial focused on Jack Kevorkian and an euthanasia case that was included in a psychology and law course. Discusses the course format, provides the reactions to the mock trial by students and consultants, and includes suggestions for improving the mock trial. (CMK)
Ischemic stroke risk reduction following cardiac surgery by carotid compression
NASA Astrophysics Data System (ADS)
Isingoma, Paul
Every year over 500,000 cardiovascular procedures requiring cardiopulmonary bypass (CPB) are performed in the United States. CPB is a technique that temporarily takes over the function of the heart and lungs during surgery, maintaining the circulation of blood and the oxygen content of the body. During CPB, an aortic cross-clamp is used to clamp the aorta and separate the systemic circulation from the outflow of the heart. Unfortunately, these procedures have been found to cause most cerebral emboli, which produce clinical, subclinical and silent neurologic injuries. Many clinical neurologic injuries occur in the postoperative period, with over 20% of the clinical strokes occurring during this period. In this study, we focus on visualizing the flow distribution in the aortic arch, the effect of carotid compression and the influence of compression time and MAP during CPB on reducing cerebral emboli. Experiments are performed with an aortic arch model in a mock cardiovascular system. Fluorescent particles are used to simulate emboli that are released into circulation immediately after carotid compression. The LVAD is used as the pump to produce flow in the system by gradually adjusting the speed to maintain desired clinical conditions. Aortic and proximal branches MAP of 65.0 +/- 5.0 mmHg (normal MAP) or 95.0 +/- 5.0 mmHg (high MAP), aortic flow of 4.0 +/- 0.5 L/min, and all branches flow (left and right carotids, and subclavian arteries) of 10% of the aortic flow. Flow distribution of particles is visualized using LaVision's DaVis imaging software and analyzed using imagej's particle analysis tool to track, count, and record particle properties from the aortic arch. Carotid compression for 10-20 seconds reduces the number of particles entering the carotid arteries by over 73% at normal MAP, and by over 85% at high MAP. A higher MAP resulted in fewer particles entering the branching vessels both at baseline and during occlusion conditions. A compression duration of 20s does not result in greater particle reduction than one of 10s. Our results demonstrate that brief compression of the common carotid arteries during an embolic shower can reduce the number of dangerous emboli by over 85%.
ERIC Educational Resources Information Center
McGuire, Patricia, Ed.; O'Brien, Edward L.; Arbetman, Lee; Mills, Vivian H.; Pannell, Andrew
Designed to facilitate the expanded use of mock trials, this manual is divided into two principle sections--a teacher's guide and a student's guide. The teacher's guide contains specific advice to teachers on all aspects of preparing for a mock trial and seven specific lesson plans for a 2- to 3-week mock trial unit. Each lesson contains…
Higgins, Rana M; Deal, Rebecca A; Rinewalt, Daniel; Hollinger, Edward F; Janssen, Imke; Poirier, Jennifer; Austin, Delores; Rendina, Megan; Francescatti, Amanda; Myers, Jonathan A; Millikan, Keith W; Luu, Minh B
2016-02-01
Determine the utility of mock oral examinations in preparation for the American Board of Surgery certifying examination (ABS CE). Between 2002 and 2012, blinded data were collected on 63 general surgery residents: 4th and 5th-year mock oral examination scores, first-time pass rates on ABS CE, and an online survey. Fifty-seven residents took the 4th-year mock oral examination: 30 (52.6%) passed and 27 (47.4%) failed, with first-time ABS CE pass rates 93.3% and 81.5% (P = .238). Fifty-nine residents took the 5th-year mock oral examination: 28 (47.5%) passed and 31 (52.5%) failed, with first-time ABS CE pass rates 82.1% and 93.5% (P = .240). Thirty-eight responded to the online survey, 77.1% ranked mock oral examinations as very or extremely helpful with ABS CE preparation. Although mock oral examinations and ABS CE passing rates do not directly correlate, residents perceive the mock oral examinations to be helpful. Copyright © 2016 Elsevier Inc. All rights reserved.
Sam, Jonathan; Pierse, Michael; Al-Qahtani, Abdullah; Cheng, Adam
2012-01-01
OBJECTIVE: To develop, implement and evaluate a simulation-based acute care curriculum in a paediatric residency program using an integrated and longitudinal approach. DESIGN: Curriculum framework consisting of three modular, year-specific courses and longitudinal just-in-time, in situ mock codes. SETTING: Paediatric residency program at BC Children’s Hospital, Vancouver, British Columbia. INTERVENTIONS: The three year-specific courses focused on the critical first 5 min, complex medical management and crisis resource management, respectively. The just-in-time in situ mock codes simulated the acute deterioration of an existing ward patient, prepared the actual multidisciplinary code team, and primed the surrounding crisis support systems. Each curriculum component was evaluated with surveys using a five-point Likert scale. RESULTS: A total of 40 resident surveys were completed after each of the modular courses, and an additional 28 surveys were completed for the overall simulation curriculum. The highest Likert scores were for hands-on skill stations, immersive simulation environment and crisis resource management teaching. Survey results also suggested that just-in-time mock codes were realistic, reinforced learning, and prepared ward teams for patient deterioration. CONCLUSIONS: A simulation-based acute care curriculum was successfully integrated into a paediatric residency program. It provides a model for integrating simulation-based learning into other training programs, as well as a model for any hospital that wishes to improve paediatric resuscitation outcomes using just-in-time in situ mock codes. PMID:23372405
Fingeret, Abbey L; Arnell, Tracey; McNelis, John; Statter, Mindy; Dresner, Lisa; Widmann, Warren
We sought to determine whether sequential participation in a multi-institutional mock oral examination affected the likelihood of passing the American Board of Surgery Certifying Examination (ABSCE) in first attempt. Residents from 3 academic medical centers were able to participate in a regional mock oral examination in the fall and spring of their fourth and fifth postgraduate year from 2011 to 2014. Candidate׳s highest composite score of all mock orals attempts was classified as risk for failure, intermediate, or likely to pass. Factors including United States Medical Licensing Examination steps 1, 2, and 3, number of cases logged, American Board of Surgery In-Training Examination performance, American Board of Surgery Qualifying Examination (ABSQE) performance, number of attempts, and performance in the mock orals were assessed to determine factors predictive of passing the ABSCE. A total of 128 mock oral examinations were administered to 88 (71%) of 124 eligible residents. The overall first-time pass rate for the ABSCE was 82%. There was no difference in pass rates between participants and nonparticipants. Of them, 16 (18%) residents were classified as at risk, 47 (53%) as intermediate, and 25 (29%) as likely to pass. ABSCE pass rate for each group was as follows: 36% for at risk, 84% for intermediate, and 96% for likely pass. The following 4 factors were associated with first-time passing of ABSCE on bivariate analysis: mock orals participation in postgraduate year 4 (p = 0.05), sequential participation in mock orals (p = 0.03), ABSQE performance (p = 0.01), and best performance on mock orals (p = 0.001). In multivariable logistic regression, the following 3 factors remained associated with ABSCE passing: ABSQE performance, odds ratio (OR) = 2.9 (95% CI: 1.3-6.1); mock orals best performance, OR = 1.7 (1.2-2.4); and participation in multiple mock oral examinations, OR = 1.4 (1.1-2.7). Performance on a multi-institutional mock oral examination can identify residents at risk for failure of the ABSCE. Sequential participation in mock oral examinations is associated with improved ABSCE first-time pass rate. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
In-pile testing of ITER first wall mock-ups at relevant thermal loading conditions
NASA Astrophysics Data System (ADS)
Litunovsky, N.; Gervash, A.; Lorenzetto, P.; Mazul, I.; Melder, R.
2009-04-01
The paper describes the experimental technique and preliminary results of thermal fatigue testing of ITER first wall (FW) water-cooled mock-ups inside the core of the RBT-6 experimental fission reactor (RIAR, Dimitrovgrad, Russia). This experiment has provided simultaneous effect of neutron fluence and thermal cycling damages on the mock-ups. A PC-controlled high-temperature graphite ohmic heater was applied to provide cyclic thermal load onto the mock-ups surface. This experiment lasted for 309 effective irradiation days with a final damage level (CuCrZr) of 1 dpa in the mock-ups. About 3700 thermal cycles with a heat flux of 0.4-0.5 MW/m 2 onto the mock-ups were realized before the heater fails. Then, irradiation was continued in a non-cycling mode.
Subhas, Gokulakkrishna; Yoo, Stephen; Chang, Yeon-Jeen; Peiper, David; Frikker, Mark J; Bouwman, David L; Silbergleit, Allen; Lloyd, Larry R; Mittal, Vijay K
2009-09-01
The Southeast Michigan Center for Medical Education (SEMCME) is a consortium of teaching hospitals in the Greater Detroit metropolitan area. SEMCME pools its resources for several educational means, including mock oral board examinations. The educational and cost benefits to mock oral examinations on a multi-institutional basis in preparation for the American Board of Surgery (ABS) certifying examination were analyzed. Ten-year multi-institution data from the mock oral examinations were correlated with ABS certifying examination pass rates. Mock oral examination scores were available for 107 of 147 graduates, which included 12 candidates who failed their certifying examination on the first attempt (pass rate = 89%). Four of 31 examinees who had a low score (4.9 or less) in their mock oral exams failed their certifying examination in their first attempt. The cost of running the mock examination was low (approximately $35/resident for 50 residents). When graduates from the last 10 years were surveyed, the majority of respondents believed that the mock oral examination helped in their success and with their preparation for the certifying examination. Thus, the many benefits of administering the examination with the resources of a consortium of hospitals result in the accurate reproduction of real-life testing conditions with reasonable overall costs per resident.
Yang, Xiaochen; Clements, Logan W; Luo, Ma; Narasimhan, Saramati; Thompson, Reid C; Dawant, Benoit M; Miga, Michael I
2017-07-01
Intraoperative soft tissue deformation, referred to as brain shift, compromises the application of current image-guided surgery navigation systems in neurosurgery. A computational model driven by sparse data has been proposed as a cost-effective method to compensate for cortical surface and volumetric displacements. We present a mock environment developed to acquire stereoimages from a tracked operating microscope and to reconstruct three-dimensional point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. When comparing our tracked microscope stereo-pair measure of mock vessel displacements to that of the measurement determined by the independent optically tracked stylus marking, the displacement error was [Formula: see text] on average. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to laser range scanners to collect sufficient intraoperative information for brain shift correction.
A Coupled THMC model of FEBEX mock-up test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Liange; Samper, Javier
2008-09-15
FEBEX (Full-scale Engineered Barrier EXperiment) is a demonstration and research project for the engineered barrier system (EBS) of a radioactive waste repository in granite. It includes two full-scale heating and hydration tests: the in situ test performed at Grimsel (Switzerland) and a mock-up test operating at CIEMAT facilities in Madrid (Spain). The mock-up test provides valuable insight on thermal, hydrodynamic, mechanical and chemical (THMC) behavior of EBS because its hydration is controlled better than that of in situ test in which the buffer is saturated with water from the surrounding granitic rock. Here we present a coupled THMC model ofmore » the mock-up test which accounts for thermal and chemical osmosis and bentonite swelling with a state-surface approach. The THMC model reproduces measured temperature and cumulative water inflow data. It fits also relative humidity data at the outer part of the buffer, but underestimates relative humidities near the heater. Dilution due to hydration and evaporation near the heater are the main processes controlling the concentration of conservative species while surface complexation, mineral dissolution/precipitation and cation exchanges affect significantly reactive species as well. Results of sensitivity analyses to chemical processes show that pH is mostly controlled by surface complexation while dissolved cations concentrations are controlled by cation exchange reactions.« less
Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki
2015-01-01
Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.
ERIC Educational Resources Information Center
Ashbrook, Alexandra M.
This guide contains the 1996 mock trial materials for the District of Columbia mock trial program. The trial focuses on a high school student who died of a heart attack attributed to the use of steroids. The plaintiff, the student's father, alleges that the school, its principal, and track coach were negligent in the death because they failed to…
Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S
Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.
Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.
Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich
2017-02-01
At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Tamaki, S; Sakai, M; Yoshihashi, S; Manabe, M; Zushi, N; Murata, I; Hoashi, E; Kato, I; Kuri, S; Oshiro, S; Nagasaki, M; Horiike, H
2015-12-01
Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error. Copyright © 2015 Elsevier Ltd. All rights reserved.
Stöcklmayer, C; Dorffner, G; Schmidt, C; Schima, H
1995-07-01
Rotary blood pumps are used in clinical applications to assist circulation via pumping blood from the left atrium to the aorta. Negative inflow pressures at high flow rates can cause suction of the cannula in the left atrium with deleterious effects on the atrial wall, the blood, and the lung. Therefore, stable and reliable detection of suction and the prediction of the left atrium pressure (LAP) would be of major interest for the control of these pumps. This work reports about an in vitro study of such a detector based on artificial neural networks (ANN). In the first project phase, an ANN was used to estimate the LAP based on pump speed, pump flow, and aortic pressure, obtained from a mock circulation. The inputs for the ANN were 11 characteristic values computed from these three parameters. In the second phase, another ANN was trained to classify various system states, such as suction, danger of suction (a state close to actual suction), and no suction. The first ANN was able to estimate the LAP with an accuracy of +/- 1.8 mm Hg. The discrimination of suction versus the other two states could be performed with a sensitivity and specificity of about 95% while the more interesting task of distinguishing danger of suction from no suction reached a sensitivity and specificity of about 65% (leaving 25% of each class unclassified and 10% of each class incorrectly classified).(ABSTRACT TRUNCATED AT 250 WORDS)
Automated Non-Destructive Testing Array Evaluation System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, T; Zavaljevski, N; Bakhtiari, S
2004-12-24
Automated Non-Destructive Testing Array Evaluation System (ANTARES) sofeware alogrithms were developed for use on X-probe(tm) data. Data used for algorithm development and preliminary perfomance determination was obtained for USNRC mock-up at Argone and data from EPRI.
Characterization of flaws in a tube bundle mock-up for reliability studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kupperman, D.S.; Bakhtiari, S.
1997-02-01
As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubesmore » were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes.« less
Nancy L. Shaw; Emerenciana G. Hurd; Peter F. Stickney
2008-01-01
The mock oranges - Philadelphus spp. - have been placed in several families: Saxifragaceae (Harrington 1954), Hydrangeaceae (Hitchcock and others 1961), and more recently, the Philadelphaceae (Hickman 1993). Hydrangeaceae, however, is the most widely accepted placement (Cronquist and others 1997; USDA NRCS 2001). There are about 50 to 65 species of mock orange,...
ERIC Educational Resources Information Center
North Carolina State Dept. of Public Instruction, Raleigh. Div. of Social Studies Education.
This materials packet contains information on teaching about the electoral process and the elections of 1988, and on participation in a mock election for students whose schools would take part in the 1988 North Carolina Mock Election. Suggestions for teachers' preparations are given, including a classroom skit and a mock candidates' election…
Sheahan, Chelsea L; Pica, Emily; Pozzulo, Joanna D
2017-09-01
The purpose of the current study was to examine the role of victim age, defendant age, and type of abuse on mock juror decision making. Mock jurors ( N = 556) read a trial transcript in which a soccer coach was accused of sexual abuse or physical abuse against a player. The victim's age (child, adolescent, or young adult), the defendant's age (young, middle age, or older adult), and the type of abuse (sexual or physical) were varied. Mock jurors provided a dichotomous and continuous verdict and rated their perceptions of the victim and the defendant. Although no differences on mock jurors' dichotomous verdict were found due to victim age, defendant age, or type of abuse, mock jurors provided higher guilt ratings when the abuse was sexual and both the victim and defendant were described as young adults. Similarly, mock jurors rated the victim more positively when the victim was described as a young adult (vs. child) for both sexual and physical abuse cases, and rated the defendant more positively when the victim was described as a child compared with young adult in sexual abuse cases. These findings suggest that mock jurors were largely influenced by victim age, particularly when the victim was described as an adult compared with a child.
Minakawa, Masahito; Fukuda, Ikuo; Yamazaki, Junichi; Fukui, Kozo; Yanaoka, Hideki; Inamura, Takao
2007-12-01
This study was designed to analyze flow pattern, velocity, and strain on the aortic wall of a glass aortic model during extracorporeal circulation, and to elucidate the characteristics of flow pattern in four aortic cannulas. Different patterns of large vortices and helical flow were made by each cannula. The high-velocity flow (0.6 m/s) was observed in end-hole cannula, causing high strain rate tensor (0.3~0.4 without unit) on the aortic arch. In dispersion cannula, a decreased strain rate tensor (less than 0.1) was found on the outer curvature of the aortic arch. In Soft-flow cannula (3M Cardiovascular, Ann Arbor, MI, USA), further decreased flow velocity (0.2 m/s) and strain (less than 0.2) were observed. In Select 3D cannula (Medtronic, Inc., Minneapolis, MN, USA), a high strain (0.4~0.5) was observed along the inner curvature of the aortic arch. In conclusion, end-hole cannula should not be used in atherosclerotic aorta. Particular attention should be paid both for selection of cannulas and cannulation site based on this result.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chauvin, J. P.; Lebrat, J. F.; Soule, R.
Since 1991, the CEA has studied the physics of hybrid systems, involving a sub-critical reactor coupled with an accelerator. These studies have provided information on the potential of hybrid systems to transmute actinides and, long lived fission products. The potential of such a system remains to be proven, specifically in terms of the physical understanding of the different phenomena involved and their modelling, as well as in terms of experimental validation of coupled systems, sub-critical environment/accelerator. This validation must be achieved through mock-up studies of the sub-critical environments coupled to a source of external neutrons. The MUSE-4 mock-up experiment ismore » planed at the MASURCA facility and will use an accelerator coupled to a tritium target. The great step between the generator used in the past and the accelerator will allow to increase the knowledge in hybrid physic and to decrease the experimental biases and the measurement uncertainties.« less
Exploring the Lived Experiences of Participants in Simulation-Based Learning Activities
ERIC Educational Resources Information Center
Beard, Rachael
2013-01-01
There is currently a small body of research on the experiences of participants, both facilitators and learners, during simulated mock codes (cardiac arrest) in the healthcare setting. This study was based on a practitioner's concerns that mock codes are facilitated differently among educators, mock codes are not aligned with andragogy theory of…
Evans, C H; Schneider, E; Shostrom, V; Schenarts, P J
2017-02-01
Today's medical learners are Millennials, and reportedly, multitasking pros. We aim to evaluate effect of multitasking on cognitive and technical skills. 16 medical students completed a mock page and laceration closure separately on day 1 and day 13, and in parallel on day 14. Suturing was graded using GRS and mock pages scored. Total time, suturing and loading times, and percent correct on mock page were compared. Percent correct on mock page improved from days 1-13 and 14 (p < 0.01 and 0.04). GRS improved from days 1-13 and 14 (p = 0.04 and <0.01). Total time suturing was similar on all days. However, time suturing during the mock page on day 14 was prolonged compared to before mock page (p = 0.01). Medical students can complete cognitive and technical tasks in parallel, without compromising acceptability. However, multitasking results in longer times to complete the complex component of the technical task. Copyright © 2016 Elsevier Inc. All rights reserved.
Carlo-Stella, Carmelo; Di Nicola, Massimo; Magni, Michele; Longoni, Paolo; Milanesi, Marco; Stucchi, Claudio; Cleris, Loredana; Formelli, Franca; Gianni, Massimo A
2002-11-01
Defibrotide is a polydeoxyribonucleotide, which significantly reduces the expression of adhesion molecules on endothelial cells. We investigated the activity of Defibrotide alone or in combination with recombinant human granulocyte colony-stimulating factor (rhG-CSF) to mobilize peripheral blood progenitor cells (PBPCs) in BALB/c mice. A 5-day treatment with Defibrotide alone (1-15 mg/mouse/day) had no effect on WBC counts, frequencies and absolute numbers of total circulating colony-forming cells (CFCs), i.e., granulocyte-macrophage colony-forming units, erythroid burst-forming units, and multilineage colony-forming units. As compared with mock-injected mice, administration of rhG-CSF alone (5 micro g/mouse/day) for 5 days significantly (P < or = 0.0001) increased WBC counts, CFC frequencies, and CFC absolute numbers by 2-, 13-, and 27-fold, respectively. As compared with control mice, the combined administration of Defibrotide (15 mg/mouse/day) and rhG-CSF significantly (P < or = 0.0001) increased WBC counts, frequencies and absolute numbers of CFCs by 4-, 38-, and 119-fold, respectively. As compared with rhG-CSF alone, administration of Defibrotide plus rhG-CSF resulted in a significant increase (P < or = 0.001) of the frequency of circulating long-term culture-initiating cells. In addition, transplantation of 2 x 10(5) rhG-CSF- or Defibrotide/rhG-CSF-mobilized mononuclear cells rescued 43% and 71% of recipient mice, respectively. Experiments of CFC homing performed in lethally irradiated or nonirradiated recipients showed that marrow homing of transplanted PBPCs was reduced by 3-fold in Defibrotide-treated animals as compared with mock-injected mice (P < or = 0.001), suggesting that the mobilizing effect of Defibrotide might be because of an effect on PBPC trafficking. In conclusion, our data demonstrate that Defibrotide synergizes with rhG-CSF and significantly increases the mobilization of a broad spectrum of PBPCs, including primitive and committed progenitor cells. These data might have relevant implications for autologous and allogeneic anticancer therapy in humans.
Can neutrino decay-driven mock gravity save hot dark matter?
NASA Technical Reports Server (NTRS)
Splinter, Randall J.; Melott, Adrian L.
1992-01-01
The radiative decay of a 30 eV neutrino with a lifetime of order 10 exp 23-24 s has recently been shown to yield a satisfactory explanation of a wide range of problems in astrophysics. In this paper, it is investigated whether the photon flux generated by the radiative decay of a massive neutrino is capable of generating sufficient radiation pressure to cause a 'mock gravitational' collapse of primordial hydrogen clouds. It is shown that when using neutral hydrogen as a source of opacity for mock gravity the time scale for mock gravitational collapse is significantly larger than the expansion time scale. Thus, the model fails as a source of galactic seed perturbations. Furthermore, it is argued that nonlinear feedback mechanisms will be unable to increase the collapse rate of the cloud under mock gravity.
Implementing newborn mock codes.
Blakely, Teresa Gail
2007-01-01
This article describes the implementation of a newborn mock code program. Although the Neonatal Resuscitation Program (NRP) is one of the most widely used health education programs in the world and is required for most hospital providers who attend deliveries, research tells us that retention of NRP skills deteriorates rapidly after completion of the course. NRP requires coordination and cooperation among all providers; however, a lack of leadership and teamwork during resuscitation (often associated with a lack of confidence) has been noted. Implementation of newborn mock code scenarios can encourage teamwork, communication, skills building, and increased confidence levels of providers. Mock codes can help providers become strong team members and team leaders by helping them be better prepared for serious situations in the delivery room. Implementation of newborn mock codes can be effectively accomplished with appropriate planning and consideration for adult learning behaviors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.
This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.
Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.; ...
2016-11-16
This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.
Commentary: Perception of remorse by mock jurors in a capital murder trial.
Batista, Leonardo M; Myers, Wade
2012-01-01
The study by Corwin et al. adds to the emerging but limited data on the impact of defendant remorse on sentencing decisions. The authors studied verbal and nonverbal expressions of defendant remorse and whether they were perceived as remorseful by mock jurors. They found that incongruent verbal and nonverbal behavior, as well as mock jurors' willingness to approach emotional situations, resulted in more lenient sentences for defendants. An overarching and as yet unanswered validity concern regarding this line of research in general is whether the use of undergraduate mock jurors reliably models real jurors in actual courtroom settings.
Mock Trials versus Management or Litigation-Driven Models of Business Law Instruction
ERIC Educational Resources Information Center
Gershuny, Pamela; McAllister, Charles; Rainey, Carolyn
2012-01-01
This study was designed to gain a greater understanding of the learning outcomes associated with the mock trial as an active teaching method. Participating in a product liability mock trial presents students with the complex interplay of administrative regulations and common law. As in real life, the harsh constraints of time pressures, less than…
ERIC Educational Resources Information Center
Michigan State Board of Education, Lansing.
An eight-chapter resource guide helps high school students become actively involved in the presidential election process. Chapter 1 contains directions for student participation in the 1984 Michigan statewide mock election; these directions are easily adaptable to other state and local mock election projects. Included are sample voter application…
Introducing Preservice Teachers to Issues Surrounding Evolution and Creationism via a Mock Trial.
ERIC Educational Resources Information Center
Helgeson, Lars J.; Hoover, John; Sheehan, James
2002-01-01
Describes cooperation between social studies and science education professors to introduce preservice teachers to the evolution versus creationism debate via a mock trial. Uses a hypothetical situation in which a 6th grade teacher was fired for not balancing evolution and creationism in his teaching. Reports that the mock trial slightly increased…
A Study of Authoring Alternatives for Training-Oriented Videodiscs.
ERIC Educational Resources Information Center
Bunderson, C. Victor; And Others
This study examined eight areas that are related to the problems of authoring and producing training-oriented videodiscs: the delivery system itself; media selection during instructional systems development; instructional strategies; author mock-up and simulation prior to premastering; premastering; mastering and replication; composition of…
Andersen, Simone Nyholm; Broberg, Ole
2015-11-01
Current application of work system simulation in participatory ergonomics (PE) design includes a variety of different simulation media. However, the actual influence of the media attributes on the simulation outcome has received less attention. This study investigates two simulation media: full-scale mock-ups and table-top models. The aim is to compare, how the media attributes of fidelity and affordance influence the ergonomics identification and evaluation in PE design of hospital work systems. The results illustrate, how the full-scale mock-ups' high fidelity of room layout and affordance of tool operation support ergonomics identification and evaluation related to the work system entities space and technologies & tools. The table-top models' high fidelity of function relations and affordance of a helicopter view support ergonomics identification and evaluation related to the entity organization. Furthermore, the study addresses the form of the identified and evaluated conditions, being either identified challenges or tangible design criteria. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
In vitro characterization of a magnetically suspended continuous flow ventricular assist device.
Kim, H C; Bearnson, G B; Khanwilkar, P S; Olsen, D B; Maslen, E H; Allaire, P E
1995-01-01
A magnetically suspended continuous flow ventricular assist device using magnetic bearings was developed aiming at an implantable ventricular assist device. The main advantage of this device includes no mechanical wear and minimal chance of blood trauma such, as thrombosis and hemolysis, because there is no mechanical contact between the stationary and rotating parts. The total system consists of two subsystems: the centrifugal pump and the magnetic bearing. The centrifugal pump is comprised of a 4 vane logarithmic spiral radial flow impeller and a brushless DC motor with slotless stator, driven by the back emf commutation scheme. Two radial and one thrust magnetic bearing that dynamically controls the position of the rotor in a radial and axial direction, respectively, contains magnetic coils, the rotor's position sensors, and feedback electronic control system. The magnetic bearing system was able to successfully suspend a 365.5g rotating part in space and sustain it for up to 5000 rpm of rotation. Average force-current square factor of the magnetic bearing was measured as 0.48 and 0.44 (kg-f/Amp2) for radial and thrust bearing, respectively. The integrated system demonstrated adequate performance in mock circulation tests by providing a 6 L/min flow rate against 100 mmHg differential pressure at 2300 rpm. Based on these in vitro performance test results, long-term clinical application of the magnetically suspended continuous flow ventricular assist device is very promising after system optimization with a hybrid system using both active (electromagnet) and passive (permanent magnets) magnet bearings.
Beus, Hannah; Fowler, Sara; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike; Jatana, Courtney
2018-02-01
There are no prospective endodontic studies to determine the outcome of an incision and drainage (I&D) procedure for swelling in healthy, endodontic patients. The purpose of this prospective, randomized, single-blind study was to compare the postoperative course of I&D with drain placement versus a mock I&D procedure with mock drain placement after endodontic debridement in swollen emergency patients with symptomatic teeth and a pulpal diagnosis of necrosis. Eighty-one adult emergency patients presenting with clinical swelling received either penicillin or, if allergic, clindamycin and complete endodontic debridement, and then were randomly divided into 2 treatment groups: I&D with drain placement or a mock I&D procedure with mock drain placement. At the end of the appointment, all patients received a combination of ibuprofen/acetaminophen and, if needed, an opioid-containing escape medication. Patients recorded their pain and medication use for 4 days postoperatively. Success was defined as no or mild postoperative pain and no use of an opioid-containing escape medication. Success was evaluated using repeated measure mixed model logistic regression. Both groups had a decrease in postoperative pain and medication use over the 4 days. The mock I&D group had significantly higher success than the I&D group (odds ratio = 2.00; 95% confidence interval, 1.16-3.41). The success rate was 45% with the mock I&D and 33% with the I&D. After endodontic debridement, patients who received a mock I&D procedure with mock drain placement had more success than patients who received I&D with drain placement. Both groups clinically improved over 4 days. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Threat detection in desert environment with passive millimeter-wave sensor
NASA Astrophysics Data System (ADS)
Wilson, John P.; Schuetz, Christopher A.; Martin, Richard D.; Dillon, Thomas E.; Murakowski, Maciej; Prather, Dennis W.
2011-06-01
A new technique for improvised explosive device (IED) creation uses an explosive device buried in foam and covered in a layer of dirt. These devices are difficult to detect visually, however, their material characteristics make them detectable by passive millimeter-wave (pmmW) sensors. Results are presented from a test using a mock IED and an outdoor set-up consisting of two mock IEDs on a dirt background. The results show that the mock IEDs produces a millimeter-wave signature which is distinguishable from the background surrounding the mock IEDs. Simulations based on the measured data are presented and a design for a future vehicle mounted sensor is shown.
Senior Medical Student Mock Interview Program in Pediatrics.
Multerer, Sara; Carothers, Becky; Patel, Pradip D; Ziegler, Craig; Rowland, Michael; Davis, Deborah Winders
2016-02-01
Residency interviews play an integral part in medical residency placement. We aimed to develop and evaluate a mock interview program for fourth-year medical students interested in a pediatric specialty. A mock interview program for fourth-year medical students interested in pediatrics was developed and implemented. Preinterview quantitative data and postinterview qualitative data were collected. Fifty-nine students completed the program across three consecutive academic years. Preinterview surveys were completed regarding comfort and confidence levels specific to aspects of the interview process. Descriptive analyses were used. In addition, a focus group was held with nine of the participating students to obtain qualitative data via a paper blog process. Themes in student responses were identified through constant comparative analysis. Before the mock interview, students were most uncomfortable with introductory and closing remarks and their confidence levels varied by topic. A thematic analysis of focus group data identified five themes (preparation, stress reduction, interview process familiarity, confidence of skills, and receiving feedback) for which the mock interviews were most helpful. Implementation of a mock interview program was feasible and acceptable for senior medical students and may improve comfort and confidence levels in the residency interview process. Further longitudinal research is needed.
Marichal, Daniel A; Anwar, Temoor; Kirsch, David; Clements, Jessica; Carlson, Luke; Savage, Clare; Rees, Chet R
2011-04-01
To evaluate the radiation protective characteristics of a system designed to enhance operator protection while eliminating weight to the body and allowing freedom of motion. Radiation doses to a mock interventionalist were measured with calibrated dosimeters in a clinical interventional suite. A standard lead apron (SLA; Pb equivalent, 0.5 mm) was compared with a suspended radiation protection system (ZeroGravity; Zgrav) that shields from the top of the head to the calves (except the right arm and left forearm) with a complex overhead motion system that eliminates weight on the operator and allows freedom of motion. Zgrav included a suspended lead apron with increased lead equivalency, greater length, proximal left arm and shoulder coverage, and a wraparound face shield of 0.5 mm Pb equivalency. A 26-cm-thick Lucite stack (ie, mock patient) created scatter during 10 controlled angiography sequences of 120 exposures each. Parameters included a field of view of 40 cm, table height of 94 cm, 124 cm from the tube to image intensifier, 50 cm from the image center to operator, 66 kVp, and 466-470 mA. Under identical conditions, average doses (SLA vs Zgrav) were 264 versus 3.4 (ratio, 78) to left axilla (P < .001), 456 versus 10.2 (ratio, 45) to left eye (P < .001), 379.4 versus 6.6 (ratio, 57) to right eye (P < .005), and 18.8 versus 1.2 (ratio, 16) to gonad (P < .001). Relative to a conventional lead apron, the Zgrav system provided a 16-78-fold decrease in radiation exposure for a mock interventionalist in a simulated clinical setting. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
D'Souza, Clive; Paquet, Victor; Lenker, James A; Steinfeld, Edward
2017-07-01
The emergence of low-floor bus designs and related regulatory standards in the U.S. have resulted in substantial improvements in public transit accessibility. However, passengers using wheeled mobility devices still experience safety concerns and inefficiencies in boarding, disembarking, and interior circulation on low-floor buses. This study investigates effects of low-floor bus interior configuration and passenger crowding on boarding and disembarking efficiency and safety. Users of manual wheelchairs (n = 18), powered wheelchairs (n = 21) and electric scooters (n = 9) simulated boarding and disembarking in three interior layout configurations at low and high passenger crowding conditions on a full-scale laboratory mock-up of a low-floor bus. Dependent measures comprised task times and critical incidents during access ramp use, fare payment, and movement to and from the doorway and wheeled mobility securement area. Individual times for unassisted boarding ranged from 15.2 to 245.3 s and for disembarking ranged from 9.1 to 164.6 s across layout and passenger crowding conditions. Nonparametric analysis of variance showed significant differences and interactions across vehicle design conditions, passenger load and mobility device type on user performance. The configuration having electronic on-board fare payment, rear-bus entrance doorways and adjacent device securement areas demonstrated greatest efficiency and safety. High passenger load adversely impacted efficiency and frequency of critical incidents during on-board circulation across all three layouts. Findings have broader implications for improving transit system efficiency and quality of service across the spectrum of transit users. Copyright © 2017 Elsevier Ltd. All rights reserved.
SiC-CMC-Zircaloy-4 Nuclear Fuel Cladding Performance during 4-Point Tubular Bend Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
IJ van Rooyen; WR Lloyd; TL Trowbridge
2013-09-01
The U.S. Department of Energy Office of Nuclear Energy (DOE NE) established the Light Water Reactor Sustainability (LWRS) program to develop technologies and other solutions to improve the reliability, sustain the safety, and extend the life of current reactors. The Advanced LWR Nuclear Fuel Development Pathway in the LWRS program encompasses strategic research focused on improving reactor core economics and safety margins through the development of an advanced fuel cladding system. Recent investigations of potential options for “accident tolerant” nuclear fuel systems point to the potential benefits of silicon carbide (SiC) cladding. One of the proposed SiC-based fuel cladding designsmore » being investigated incorporates a SiC ceramic matrix composite (CMC) as a structural material supplementing an internal Zircaloy-4 (Zr-4) liner tube, referred to as the hybrid clad design. Characterization of the advanced cladding designs will include a number of out-of-pile (nonnuclear) tests, followed by in-pile irradiation testing of the most promising designs. One of the out-of-pile characterization tests provides measurement of the mechanical properties of the cladding tube using four point bend testing. Although the material properties of the different subsystems (materials) will be determined separately, in this paper we present results of 4-point bending tests performed on fully assembled hybrid cladding tube mock-ups, an assembled Zr-4 cladding tube mock-up as a standard and initial testing results on bare SiC-CMC sleeves to assist in defining design parameters. The hybrid mock-up samples incorporated SiC-CMC sleeves fabricated with 7 polymer impregnation and pyrolysis (PIP) cycles. To provide comparative information; both 1- and 2-ply braided SiC-CMC sleeves were used in this development study. Preliminary stress simulations were performed using the BISON nuclear fuel performance code to show the stress distribution differences for varying lengths between loading points and clad configurations. The 2-ply sleeve samples show a higher bend momentum compared to those of the 1-ply sleeve samples. This is applicable to both the hybrid mock-up and bare SiC-CMC sleeve samples. Comparatively both the 1- and 2-ply hybrid mock-up samples showed a higher bend stiffness and strength compared with the standard Zr-4 mock-up sample. The characterization of the hybrid mock-up samples showed signs of distress and preliminary signs of fraying at the protective Zr-4 sleeve areas for the 1-ply SiC-CMC sleeve. In addition, the microstructure of the SiC matrix near the cracks at the region of highest compressive bending strain shows significant cracking and flaking. The 2-ply SiC-CMC sleeve samples showed a more bonded, cohesive SiC matrix structure. This cracking and fraying causes concern for increased fretting during the actual use of the design. Tomography was proven as a successful tool to identify open porosity during pre-test characterization. Although there is currently insufficient data to make conclusive statements regarding the overall merit of the hybrid cladding design, preliminary characterization of this novel design has been demonstrated.« less
Statement of Facts for 1993 City-Wide Mock Trial Competitions. Sandra W. v. Gregg M.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its 22nd annual city-wide mock trial competition, this instructional handout provides the material for a mock civil trial in which Sandra Williams sues Gregg Mason for negligent transmission of the Human Immuno-Deficient Virus (HIV). On the night of May 15, 1990, Sandra and Gregg engaged…
NASA Astrophysics Data System (ADS)
Torres-Xirau, I.; Olaciregui-Ruiz, I.; Rozendaal, R. A.; González, P.; Mijnheer, B. J.; Sonke, J.-J.; van der Heide, U. A.; Mans, A.
2017-08-01
In external beam radiotherapy, electronic portal imaging devices (EPIDs) are frequently used for pre-treatment and for in vivo dose verification. Currently, various MR-guided radiotherapy systems are being developed and clinically implemented. Independent dosimetric verification is highly desirable. For this purpose we adapted our EPID-based dose verification system for use with the MR-Linac combination developed by Elekta in cooperation with UMC Utrecht and Philips. In this study we extended our back-projection method to cope with the presence of an extra attenuating medium between the patient and the EPID. Experiments were performed at a conventional linac, using an aluminum mock-up of the MRI scanner housing between the phantom and the EPID. For a 10 cm square field, the attenuation by the mock-up was 72%, while 16% of the remaining EPID signal resulted from scattered radiation. 58 IMRT fields were delivered to a 20 cm slab phantom with and without the mock-up. EPID reconstructed dose distributions were compared to planned dose distributions using the γ -evaluation method (global, 3%, 3 mm). In our adapted back-projection algorithm the averaged {γmean} was 0.27+/- 0.06 , while in the conventional it was 0.28+/- 0.06 . Dose profiles of several square fields reconstructed with our adapted algorithm showed excellent agreement when compared to TPS.
Fast and accurate mock catalogue generation for low-mass galaxies
NASA Astrophysics Data System (ADS)
Koda, Jun; Blake, Chris; Beutler, Florian; Kazin, Eyal; Marin, Felipe
2016-06-01
We present an accurate and fast framework for generating mock catalogues including low-mass haloes, based on an implementation of the COmoving Lagrangian Acceleration (COLA) technique. Multiple realisations of mock catalogues are crucial for analyses of large-scale structure, but conventional N-body simulations are too computationally expensive for the production of thousands of realizations. We show that COLA simulations can produce accurate mock catalogues with a moderate computation resource for low- to intermediate-mass galaxies in 1012 M⊙ haloes, both in real and redshift space. COLA simulations have accurate peculiar velocities, without systematic errors in the velocity power spectra for k ≤ 0.15 h Mpc-1, and with only 3-per cent error for k ≤ 0.2 h Mpc-1. We use COLA with 10 time steps and a Halo Occupation Distribution to produce 600 mock galaxy catalogues of the WiggleZ Dark Energy Survey. Our parallelized code for efficient generation of accurate halo catalogues is publicly available at github.com/junkoda/cola_halo.
Bayramzadeh, Sara; Joseph, Anjali; Allison, David; Shultz, Jonas; Abernathy, James
2018-07-01
This paper describes the process and tools developed as part of a multidisciplinary collaborative simulation-based approach for iterative design and evaluation of operating room (OR) prototypes. Full-scale physical mock-ups of healthcare spaces offer an opportunity to actively communicate with and to engage multidisciplinary stakeholders in the design process. While mock-ups are increasingly being used in healthcare facility design projects, they are rarely evaluated in a manner to support active user feedback and engagement. Researchers and architecture students worked closely with clinicians and architects to develop OR design prototypes and engaged clinical end-users in simulated scenarios. An evaluation toolkit was developed to compare design prototypes. The mock-up evaluation helped the team make key decisions about room size, location of OR table, intra-room zoning, and doors location. Structured simulation based mock-up evaluations conducted in the design process can help stakeholders visualize their future workspace and provide active feedback. Copyright © 2018 Elsevier Ltd. All rights reserved.
Baker, Philip R A; Francis, Daniel P; Cathcart, Abby
2017-04-01
The study's objective was to apply and assess an active learning approach to epidemiology and critical appraisal. Active learning comprised a mock, randomized controlled trial (RCT) conducted with learners in 3 countries. The mock trial consisted of blindly eating red Smarties candy (intervention) compared to yellow Smarties (control) to determine whether red Smarties increase happiness. Audience response devices were employed with the 3-fold purposes to produce outcome data for analysis of the effects of red Smarties, identify baseline and subsequent changes in participant's knowledge and confidence in understanding of RCTs, and assess the teaching approach. Of those attending, 82% (117 of 143 learners) participated in the trial component. Participating in the mock trial was a positive experience, and the use of the technology aided learning. The trial produced data that learners analyzed in "real time" during the class. The mock RCT is a fun and engaging approach to teaching RCTs and helping students to develop skills in critical appraisal.
Commerical Crew Astronauts Evaluate Crew Dragon Controls
2017-01-10
Astronaut Bob Behnken, work in a mock-up of the SpaceX Crew Dragon flight deck at the company's Hawthorne, California, headquarters as development of the crew systems continues for eventual missions to the International Space Station.
Shrestha, Deepak; McAuslane, Heather J; Adkins, Scott T; Smith, Hugh A; Dufault, Nicholas; Colee, James; Webb, Susan E
2017-08-01
Plant viruses may indirectly affect insect vector behavior and fitness via a shared host plant. Here, we evaluated the host-mediated effects of Squash vein yellowing virus (SqVYV) on the behavior and fitness of its whitefly vector, Bemisia tabaci (Gennadius) Middle East-Asia Minor 1, formerly biotype B. Alighting, settling, and oviposition behavioral assays were conducted on infected and mock-inoculated squash (Cucurbita pepo L.) and watermelon [Citrullus lanatus (Thunb) Matsum and Nakai] plants. Developmental time of immature stages, adult longevity, and fecundity were measured on infected and mock-inoculated squash plants. For adult longevity and fecundity, whiteflies were reared on infected and mock-inoculated squash plants to determine the effects of nymphal rearing host on the adult stage. More whiteflies alighted and remained settled on infected squash than on mock-inoculated squash 0.25, 1, 8, and 24 h after release. No such initial preference was observed on watermelon plants, but by 8 h after release, more whiteflies were found on mock-inoculated watermelon plants than on infected plants. Whiteflies laid approximately six times more eggs on mock-inoculated watermelon than on infected watermelon; however, no differences were observed on squash. Development from egg to adult emergence was 3 d shorter on infected than mock-inoculated squash plants. Females lived 25% longer and had higher fecundity on infected squash plants than on mock-inoculated plants, regardless of infection status of the rearing host. The host-mediated effects of SqVYV infection on whitefly behavior differ on two cucurbit host plants, suggesting the potential for more rapid spread of the virus within watermelon fields. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Thermal mock-up studies of the Belle II vertex detector
NASA Astrophysics Data System (ADS)
Ye, H.; Niebuhr, C.; Stever, R.; Gadow, K.; Camien, C.
2018-07-01
The ongoing upgrade of the asymmetric electron-positron collider SuperKEKB at the KEK laboratory, Japan aims at a 40-fold increase of the peak luminosity to 8 × 1035 cm-2s-1. At the same time the complex Belle II detector is being significantly upgraded to be able to cope with the higher background level and trigger rates and to improve overall performance. The goal of the experiment is to explore physics beyond the standard model with a target integrated luminosity of 50 ab-1 in the next decade. The new vertex detector (VXD), comprising two layers of DEPFET pixel detectors (PXD) surrounded by 4 layers of double sided silicon strip detectors (SVD), is indispensable for vertex determination as well as for reconstruction of low momentum tracks that do not reach the central drift chamber (CDC). Within the confined VXD volume the front-end electronics of the two detectors will dissipate about 1 kW of heat. The VXD cooling system has been designed to remove this heat with the constraint to minimize extra dead material in the physics acceptance region. Taking into account additional heat intake from the environment the cooling system must have a cooling capacity of 2-3 kW. To achieve this goal evaporative two-phase CO2 cooling in combination with forced N2 flow is used in the VXD cooling system. In order to verify and optimize the cooling concept and to demonstrate that acceptable operation conditions for the VXD system as well as the surrounding CDC can be obtained, a full size VXD thermal mock-up has been built at DESY. Various thermal and mechanical tests carried out with this mock-up are reported.
Pedreira, Amanda A; Wanderley, Flavia G; Sa, Maira F; Viena, Camila S; Perez, Adriano; Hoshi, Ryuichi; Leite, Marcia P; Reis, Silvia R; Medrado, Alena P
2016-08-01
A randomized, blind, controlled clinical study was conducted with a convenience sample of 24 patients to evaluate the effectiveness of an aluminum gallium arsenide (AlGaAs) infrared laser 808 nm after third molar extraction by the use of infrared thermography technique. Patients were divided into four groups: erupted third molars were extracted from the patients in Group I and Group II, and impacted third molars were extracted from the patients in Group III and Group IV. Group I and Group III received mock laser therapy in which the device was powered off, and Group II and Group IV were exposed to laser light. Postoperative clinical parameters related to the third molar extraction were evaluated; these parameters included pain, trismus and edema. Circulatory patterns were also evaluated by infrared thermography that exhibited local temperature coefficient at different postoperative periods. A slight improvement was observed for swelling, pain and trismus in patients who received laser irradiation, although the differences were not statistically significant (P>0.05). Laser therapy had a significant influence on the local circulation in the area near the temporomandibular joint, as determined by infrared thermography (P<0.05). Laser therapy was able to change the local circulation, although it did not significantly influence swelling, pain or trismus during the postoperative period.
Building 9 ISS mock-ups and trainers
1999-08-02
Photographic documentation showing the bldg. 9 ISS module mock-ups and trainers. Views include: various overall views of the configuration of the ISS module trainers on the floor of bldg. 9 (08445-46, 08449-51, 08458-61, 08464-65, 08469, 08471, 08476); various portions of the mock-ups (08447-48, 08470); views of the Node 2, Experiment Module and Logistics Module (08452); Node 2 (08453, 08466); Destiny and Node 2 (08454); Destiny, Unity and Airlock (08455); Zarya, Service Module and shuttle mock-ups (08456); Logistics Module and Experiment Module (08457, 08468); various views of Columbia, Node 2 and Destiny (08462-63); Columbus, Node 2, Experiment Module and Logistics Module (08467); U.S. Laboratory module (08472); Logistics Module (08473); module layout (08474); Logistics Module and Experiment Module (08475).
Bartoli, Carlo R; Kang, Jooeun; Zhang, David; Howard, Jessica; Acker, Michael; Atluri, Pavan; Motomura, Tadashi
2017-04-01
Supraphysiologic shear stress from continuous-flow left ventricular assist devices (LVADs) accelerates von Willebrand factor (vWF) degradation and predisposes patients to nonsurgical bleeding. It is unknown whether unique design characteristics of LVADs differentially affect vWF degradation. We tested the hypothesis that the centrifugal-flow EVAHEART (Evaheart, Houston, TX) left ventricular assist system (LVAS), which was designed to minimize shear stress (low operational revolutions per minute [rpm], larger flow gaps, low shear stress, flat H-Q curve), reduced vWF degradation versus the axial-flow HeartMate II (Thoratec, Pleasanton, CA) LVAD. Whole human blood was obtained from volunteer donors (n = 22). Blood was circulated for 12 hours in mock circulatory loops through a HeartMate II (n = 10; 11,400 rpm, 6.3 ± 0.8 L/min, 76 ± 2 mm Hg) or an EVAHEART LVAS (n = 12; 2,300 rpm, 5.7 ± 0.1 L/min, 80 ± 1 mm Hg). vWF degradation was characterized with electrophoresis and immunoblotting for large vWF multimers and 11 vWF degradation fragments. The HeartMate II eliminated large vWF multimers and significantly (p < 0.05) increased 10 of 11 vWF degradation fragments at 6 and 12 hours. The increase was approximately 2.0-fold at 6 hours and 2.2-fold at 12 hours. In contrast, the EVAHEART LVAS modestly reduced large vWF multimers and significantly increased 5 of 11 and 8 of 11 vWF degradation fragments at 6 and 12 hours, respectively. The increase was approximately 1.5-fold at 6 hours and 1.7-fold at 12 hours. The EVAHEART LVAS caused significantly less degradation (p < 0.01) than the HeartMate II of the 140 kDa vWF fragment (cleavage product of ADAMTS-13, the vWF protease). The EVAHEART LVAS caused significantly less vWF degradation than the HeartMate II in a mock circulatory loop with whole human blood. LVAD design features may minimize vWF degradation. These data may inform the design and operation of next-generation LVADs to minimize blood trauma. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M
2011-09-01
The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support capabilities of both the IABP and the Impella 2.5 LP strongly depended on the simulated hemodynamic conditions. Maximum hemodynamic benefits were achieved when mechanical circulatory support was applied on a simulated scenario of deep CS. © 2011, Copyright Eindhoven University of Technology (TU/e). Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Passive control of a biventricular assist device with compliant inflow cannulae.
Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel
2012-08-01
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Programmable prostate palpation simulator using property-changing pneumatic bladder.
Talhan, Aishwari; Jeon, Seokhee
2018-05-01
The currently available prostate palpation simulators are based on either a physical mock-up or pure virtual simulation. Both cases have their inherent limitations. The former lacks flexibility in presenting abnormalities and scenarios because of the static nature of the mock-up and has usability issues because the prostate model must be replaced in different scenarios. The latter has realism issues, particularly in haptic feedback, because of the very limited performance of haptic hardware and inaccurate haptic simulation. This paper presents a highly flexible and programmable simulator with high haptic fidelity. Our new approach is based on a pneumatic-driven, property-changing, silicone prostate mock-up that can be embedded in a human torso mannequin. The mock-up has seven pneumatically controlled, multi-layered bladder cells to mimic the stiffness, size, and location changes of nodules in the prostate. The size is controlled by inflating the bladder with positive pressure in the chamber, and a hard nodule can be generated using the particle jamming technique; the fine sand in the bladder becomes stiff when it is vacuumed. The programmable valves and system identification process enable us to precisely control the size and stiffness, which results in a simulator that can realistically generate many different diseases without replacing anything. The three most common abnormalities in a prostate are selected for demonstration, and multiple progressive stages of each abnormality are carefully designed based on medical data. A human perception experiment is performed by actual medical professionals and confirms that our simulator exhibits higher realism and usability than do the conventional simulators. Copyright © 2018 Elsevier Ltd. All rights reserved.
Continuous-Grouped-Self-Learning: In the Perspective of Lecturers, Tutors and Laboratory Instructors
ERIC Educational Resources Information Center
Azau, Mohd Azrin Mohd; Yao, Low Ming; Aik, Goo Soon; Yeong, Chin Kock; Nor, Mohamad Nizam; Abdullah, Ahmad Yusri; Jamil, Mohd Hafidz Mohamad; Yahya, Nasiruddin; Abas, Ahmad Fauzi; Saripan, M. Iqbal
2009-01-01
This paper presents the perception of lecturers, tutors and lab instructors towards the implemented Continuous-Group-Self-Learning (CGSL) in the Department of Computer and Communication System Engineering (CCSE), Universiti Putra Malaysia. This innovative system introduces mock teaching and student-lecturer role as a technique of delivery. The…
Guldner, N W; Klapproth, P; Grossherr, M; Brügge, A; Sheikhzadeh, A; Tölg, R; Rumpel, E; Noel, R; Sievers, H H
2001-08-07
As shown previously in goats, clenbuterol increased the power of electrically conditioned skeletal muscle ventricles (SMVs) of clinically relevant size (150 mL), which were constructed around a mock system. They pumped against a pressure of 60 to 70 mm Hg immediately during surgery and up to several months after, finally at >1 L/min. SMVs without clenbuterol administration failed. Thus, we expected that clenbuterol-supported SMVs might become integrated into the circulation by a 1-step operation instead of the 2-step procedure required up to now. In adult Boer goats (n=5), latissimus dorsi muscle was wrapped around a polyurethane chamber of 150 mL that was connected to the descending aorta. This muscular flow-through pumping chamber containing a stabilizing inner layer (called a biomechanical heart [BMH]) was formed and immediately made to work against a systemic load with the support of clenbuterol (5x150 microg/wk). During surgery, the mean stroke volume of BMHs was 53.8+/-22.4 mL. One month after surgery, in peripheral arterial pressure, the mean diastolic (P(MD)) and minimal diastolic (P(min)) pressures of BMH-supported heart cycles differed significantly from unsupported ones (P(MD)=+2.9+/-1.1 mm Hg [P<0.04], P(min)=-2.4+/-0.9 mm Hg [P<0.04]). After BMH-supported heart contractions, the subsequent maximal rate of pressure generation, dP/dt(max), increased by 20.5+/-8.1% (P<0.02). One BMH, catheterized 132 days after surgery, shifted a volume of 34.8 mL per beat and 1.4 L/min with a latissimus dorsi muscle of 330 g. Depending on duration of training, the percentage of myosin heavy chain type 1 ranged between 31% and 100%. Under support of clenbuterol, BMHs of a clinically relevant size can be trained effectively in the systemic circulation after a 1-step operation and offer the prospect of a sufficient volume shift and probably unloading of the left ventricle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerke, Brian F.; Wechsler, Risa H.; Behroozi, Peter S.
We develop empirical methods for modeling the galaxy population and populating cosmological N-body simulations with mock galaxies according to the observed properties of galaxies in survey data. We use these techniques to produce a new set of mock catalogs for the DEEP2 Galaxy Redshift Survey based on the output of the high-resolution Bolshoi simulation, as well as two other simulations with different cosmological parameters, all of which we release for public use. The mock-catalog creation technique uses subhalo abundance matching to assign galaxy luminosities to simulated dark-matter halos. It then adds color information to the resulting mock galaxies in amore » manner that depends on the local galaxy density, in order to reproduce the measured color-environment relation in the data. In the course of constructing the catalogs, we test various models for including scatter in the relation between halo mass and galaxy luminosity, within the abundance-matching framework. We find that there is no constant-scatter model that can simultaneously reproduce both the luminosity function and the autocorrelation function of DEEP2. This result has implications for galaxy-formation theory, and it restricts the range of contexts in which the mock catalogs can be usefully applied. Nevertheless, careful comparisons show that our new mock catalogs accurately reproduce a wide range of the other properties of the DEEP2 catalog, suggesting that they can be used to gain a detailed understanding of various selection effects in DEEP2.« less
Component fears of claustrophobia associated with mock magnetic resonance imaging.
McGlynn, F Dudley; Smitherman, Todd A; Hammel, Jacinda C; Lazarte, Alejandro A
2007-01-01
A conceptualization of claustrophobia [Rachman, S., & Taylor, S. (1993). Analyses of claustrophobia. Journal of Anxiety Disorders, 7, 281-291] was evaluated in the context of magnetic resonance imaging. One hundred eleven students responded to questionnaires that quantified fear of suffocation, fear of restriction, and sensitivity to anxiety symptoms. Sixty-four of them were then exposed to a mock magnetic resonance imaging assessment; maximum subjective fear during the mock assessment was self-reported, behavioral reactions to the mock assessment were characterized, and heart rates before and during the assessment were recorded. Scores for fear of suffocation, fear of restriction, and anxiety sensitivity were used to predict subjective, behavioral, and cardiac fear. Subjective fear during the mock assessment was predicted by fears of suffocation and public anxiousness. Behavioral fear (escape/avoidance) was predicted by fears of restriction and suffocation, and sensitivity to symptoms related to suffocation. Cardiac fear was predicted by fear of public anxiousness. The criterion variance predicted was impressive, clearly sufficient to legitimize both the research preparation and the conceptualization of claustrophobia that was evaluated.
The Theoretical Astrophysical Observatory: Cloud-based Mock Galaxy Catalogs
NASA Astrophysics Data System (ADS)
Bernyk, Maksym; Croton, Darren J.; Tonini, Chiara; Hodkinson, Luke; Hassan, Amr H.; Garel, Thibault; Duffy, Alan R.; Mutch, Simon J.; Poole, Gregory B.; Hegarty, Sarah
2016-03-01
We introduce the Theoretical Astrophysical Observatory (TAO), an online virtual laboratory that houses mock observations of galaxy survey data. Such mocks have become an integral part of the modern analysis pipeline. However, building them requires expert knowledge of galaxy modeling and simulation techniques, significant investment in software development, and access to high performance computing. These requirements make it difficult for a small research team or individual to quickly build a mock catalog suited to their needs. To address this TAO offers access to multiple cosmological simulations and semi-analytic galaxy formation models from an intuitive and clean web interface. Results can be funnelled through science modules and sent to a dedicated supercomputer for further processing and manipulation. These modules include the ability to (1) construct custom observer light cones from the simulation data cubes; (2) generate the stellar emission from star formation histories, apply dust extinction, and compute absolute and/or apparent magnitudes; and (3) produce mock images of the sky. All of TAO’s features can be accessed without any programming requirements. The modular nature of TAO opens it up for further expansion in the future.
Millimeter wave experiment of ITER equatorial EC launcher mock-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, K.; Oda, Y.; Kajiwara, K.
2014-02-12
The full-scale mock-up of the equatorial launcher was fabricated in basis of the baseline design to investigate the mm-wave propagation properties of the launcher, the manufacturability, the cooling line management, how to assemble the components and so on. The mock-up consists of one of three mm-wave transmission sets and one of eight waveguide lines can deliver the mm-wave power. The mock-up was connected to the ITER compatible transmission line and the 170GHz gyrotron and the high power experiment was carried out. The measured radiation pattern of the beam at the location of 2.5m away from the EL mock-up shows themore » successful steering capability of 20°∼40°. It was also revealed that the radiated profile at both steering and fixed focusing mirror agreed with the calculation. The result also suggests that some unwanted modes are included in the radiated beam. Transmission of 0.5MW-0.4sec and of 0.12MW-50sec were also demonstrated.« less
Attractive but guilty: deliberation and the physical attractiveness bias.
Patry, Marc W
2008-06-01
The current study examined the effect of jury deliberation on the tendency for mock jurors to find attractive defendants guilty less often. It was expected that there would be an interaction between group deliberation (yes or no) and defendant's appearance (plain-looking or attractive). It was hypothesized that mock jurors who did not deliberate would be more likely to find a plain-looking defendant guilty and that deliberation would mitigate this effect. The study was a 2 x 2 between-subjects factorial design. Participants were assigned randomly to one of four conditions: attractive defendant/deliberation, attractive defendant/no deliberation, plain-looking defendant/deliberation, and plain-looking defendant/no deliberation. A total of 172 undergraduates from a small, rural college in Vermont contributed to this study: mock jurors were 70 men and 52 women, ages ranged from 18 to 52 years (M=20.5, SD=4.9). The hypothesis was supported. Mock jurors who did not deliberate were more likely to find the plain-looking defendant guilty, whereas mock jurors who deliberated were more likely to find the attractive defendant guilty.
Commerical Crew Astronauts Evaluate Crew Dragon Controls
2017-01-10
Astronauts Eric Boe, right, and Bob Behnken work in a mock-up of the SpaceX Crew Dragon flight deck at the company's Hawthorne, California, headquarters as development of the crew systems continues for eventual missions to the International Space Station.
Commerical Crew Astronauts Evaluate Crew Dragon Controls
2017-01-10
Astronauts Bob Behnken, left, and Eric Boe work in a mock-up of the SpaceX Crew Dragon flight deck at the company's Hawthorne, California, headquarters as development of the crew systems continues for eventual missions to the International Space Station.
Placement of direct composite veneers utilizing a silicone buildup guide and intraoral mock-up.
Behle, C
2000-04-01
The indications for direct composite resins have recently been expanded to include predictable and convenient application in the aesthetic zone. The availability of composite materials with improved physical and optical characteristics facilitates the development of enhanced aesthetics while maintaining vital function. This article presents a simplified technique that combines function with aesthetics by utilizing an intraoral composite mock-up for initial communication and a lingual/incisal silicone stent of the mock-up to transfer the information to the definitive restorative buildup.
Técnica de Construcción de Catálogos Sintéticos
NASA Astrophysics Data System (ADS)
Díaz, M. E.; Muriel, H.; Merchán, M.
We present a mock catalogue construction technic which enable us to mimic simultaniously several observational properties, such as spectral types, angular positions, redshifts distribution, aparent and absolut magnitudes and gravitational evolution. We analyze some prescriptions for volume and flux limited samples. As an aplication, we present a mock catalogue of the 2dF redshift survey and the corresponding comparison between the observational properties of the real data and the corresponding to the mock catalogue constructed in this work.
GEMINI-TITAN (GT)-9 - MOCKUP - ADAPTER EQUIPMENT SECTION - FUEL CELL - MSC
1966-03-01
S66-22686 (March 1966) --- Mock-up of the adapter equipment section to be used on the Gemini-9 spaceflight. This section provides volume and attach points for several system modules, including Orbit Attitude Maneuver System, Environmental Control System primary oxygen supply, batteries, coolant, and electrical and electric components. This section will also hold the Astronaut Maneuvering Unit (AMU) backpack (center). Photo credit: NASA
Zhu, Shidong; Luo, Lin; Yang, Bibo; Li, Xinghui; Wang, Xiaohao
2017-12-01
Ventricular assist devices (LVADs) are increasingly recognized for supporting blood circulation in heart failure patients who are non-transplant eligible. Because of its volume, the traditional pulsatile device is not easy to implant intracorporeally. Continuous flow LVADs (CF-LVADs) reduce arterial pulsatility and only offer continuous flow, which is different from physiological flow, and may cause long-term complications in the cardiovascular system. The aim of this study was to design a new pulsatile assist device that overcomes this disadvantage, and to test this device in the cardiovascular system. Firstly, the input and output characteristics of the new device were tested in a simple cardiovascular mock system. A detailed mathematical model was established by fitting the experimental data. Secondly, the model was tested in four pathological cases, and was simulated and coupled with a fifth-order cardiovascular system and a new device model using Matlab software. Using assistance of the new device, we demonstrated that the left ventricle pressure, aortic pressure, and aortic flow of heart failure patients improved to the levels of a healthy individual. Especially, in state IV level heart failure patients, the systolic blood pressure increased from 81.34 mmHg to 132.1 mmHg, whereas the diastolic blood pressure increased from 54.28 mmHg to 78.7 mmHg. Cardiac output increased from 3.21 L/min to 5.16 L/min. The newly-developed assist device not only provided a physiological flow that was similar to healthy individuals, but also effectively improved the ability of the pathological ventricular volume. Finally, the effects of the new device on other hemodynamic parameters are discussed.
Director's Corner: Professional Development Workshop Helps Early Stage Investigators
The Professional Development and Mock Review Workshop is a seminal event organized each year for CURE scholars and trainees. The event includes informative presentations, interactive discussions, a mock review, and poster session.
Thermal Fatigue Study on the Divertor Plate Materials
NASA Astrophysics Data System (ADS)
Wu, Ji-hong; Zhang, Fu; Xu, Zeng-yu; Yan, Jian-cheng
2002-10-01
Thermal fatigue property of the divertor plate is one of the key issues that governs the lifetime of the divertor plate. Taking tungsten as surface material, a small-mock-up divertor plate was made by hot isostatic press welding (HIP). A thermal cycling experiment for divertor mock-up was carried out in the vacuum, where a high-heat-flux electronic gun was used as the thermal source. A cyclic heat flux of 9 MW/m2 was loaded onto the mock-up, a heating duration of 20 s was selected, the cooling water flow rate was 80 ml/s. After 1000 cycles, the surface and the W/Cu joint of the mock-up did not show any damage. The SEM was used to analyze the microstructure of the welding joint, where no cracks were found also.
Can paediatric medical students devise a satisfactory standard of examination for their colleagues?
Cunningham, S
1999-06-01
To determine what standard paediatric medical students would set for examining their peers and how that would compare with the university standard. Single blinded computer marked examination with questionnaire. University medical school. Medical students during their final paediatric attachment. Medical students asked to derive 10, five branch negatively marked multiple choice questions (MCQs) to a standard that would fail those without sufficient knowledge. Each 10 were then assessed by another student as to the degree of difficulty and the relevance to paediatrics. One year later student peers sat a mock MCQ examination derived from a random 40 questions (unaware that the mock MCQs had been derived by peers). Comparison of marks obtained in mock and final MCQ examinations; student perception of the standard in the two examinations assessed by questionnaire. 44 students derived 439 questions, of which 83% were considered an appropriate standard by a classmate. One year later 62 students sat the mock examination. Distribution of marks was better in the mock MCQ examination than the final MCQ examination. Students considered the mock questions to be a more appropriate standard (72% v 31%) and the topics more relevant (88% v 64%) to paediatric medical students. Questions were of a similar clarity in both examinations (73% v 78%). Students in this study were able to derive an examination of a satisfactory standard for their peers. Involvement of students in deriving examination standards may give them a better appreciation of how standards should be set and maintained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berlind, Andreas A.; Frieman, Joshua A.; Weinberg, David H.
2006-01-01
We identify galaxy groups and clusters in volume-limited samples of the SDSS redshift survey, using a redshift-space friends-of-friends algorithm. We optimize the friends-of-friends linking lengths to recover galaxy systems that occupy the same dark matter halos, using a set of mock catalogs created by populating halos of N-body simulations with galaxies. Extensive tests with these mock catalogs show that no combination of perpendicular and line-of-sight linking lengths is able to yield groups and clusters that simultaneously recover the true halo multiplicity function, projected size distribution, and velocity dispersion. We adopt a linking length combination that yields, for galaxy groups withmore » ten or more members: a group multiplicity function that is unbiased with respect to the true halo multiplicity function; an unbiased median relation between the multiplicities of groups and their associated halos; a spurious group fraction of less than {approx}1%; a halo completeness of more than {approx}97%; the correct projected size distribution as a function of multiplicity; and a velocity dispersion distribution that is {approx}20% too low at all multiplicities. These results hold over a range of mock catalogs that use different input recipes of populating halos with galaxies. We apply our group-finding algorithm to the SDSS data and obtain three group and cluster catalogs for three volume-limited samples that cover 3495.1 square degrees on the sky. We correct for incompleteness caused by fiber collisions and survey edges, and obtain measurements of the group multiplicity function, with errors calculated from realistic mock catalogs. These multiplicity function measurements provide a key constraint on the relation between galaxy populations and dark matter halos.« less
Galaxy and Mass Assembly (GAMA): the GAMA galaxy group catalogue (G3Cv1)
NASA Astrophysics Data System (ADS)
Robotham, A. S. G.; Norberg, P.; Driver, S. P.; Baldry, I. K.; Bamford, S. P.; Hopkins, A. M.; Liske, J.; Loveday, J.; Merson, A.; Peacock, J. A.; Brough, S.; Cameron, E.; Conselice, C. J.; Croom, S. M.; Frenk, C. S.; Gunawardhana, M.; Hill, D. T.; Jones, D. H.; Kelvin, L. S.; Kuijken, K.; Nichol, R. C.; Parkinson, H. R.; Pimbblet, K. A.; Phillipps, S.; Popescu, C. C.; Prescott, M.; Sharp, R. G.; Sutherland, W. J.; Taylor, E. N.; Thomas, D.; Tuffs, R. J.; van Kampen, E.; Wijesinghe, D.
2011-10-01
Using the complete Galaxy and Mass Assembly I (GAMA-I) survey covering ˜142 deg2 to rAB= 19.4, of which ˜47 deg2 is to rAB= 19.8, we create the GAMA-I galaxy group catalogue (G3Cv1), generated using a friends-of-friends (FoF) based grouping algorithm. Our algorithm has been tested extensively on one family of mock GAMA lightcones, constructed from Λ cold dark matter N-body simulations populated with semi-analytic galaxies. Recovered group properties are robust to the effects of interlopers and are median unbiased in the most important respects. G3Cv1 contains 14 388 galaxy groups (with multiplicity ≥2), including 44 186 galaxies out of a possible 110 192 galaxies, implying ˜40 per cent of all galaxies are assigned to a group. The similarities of the mock group catalogues and G3Cv1 are multiple: global characteristics are in general well recovered. However, we do find a noticeable deficit in the number of high multiplicity groups in GAMA compared to the mocks. Additionally, despite exceptionally good local spatial completeness, G3Cv1 contains significantly fewer compact groups with five or more members, this effect becoming most evident for high multiplicity systems. These two differences are most likely due to limitations in the physics included of the current GAMA lightcone mock. Further studies using a variety of galaxy formation models are required to confirm their exact origin. The G3Cv1 catalogue will be made publicly available as and when the relevant GAMA redshifts are made available at .
Mechanical Characterization of the Iter Mock-Up Insulation after Reactor Irradiation
NASA Astrophysics Data System (ADS)
Prokopec, R.; Humer, K.; Fillunger, H.; Maix, R. K.; Weber, H. W.
2010-04-01
The ITER mock-up project was launched in order to demonstrate the feasibility of an industrial impregnation process using the new cyanate ester/epoxy blend. The mock-up simulates the TF winding pack cross section by a stainless steel structure with the same dimensions as the TF winding pack at a length of 1 m. It consists of 7 plates simulating the double pancakes, each of them is wrapped with glass fiber/Kapton sandwich tapes. After stacking the 7 plates, additional insulation layers are wrapped to simulate the ground insulation. This paper presents the results of the mechanical quality tests on the mock-up pancake insulation. Tensile and short beam shear specimens were cut from the plates extracted from the mock-up and tested at 77 K using a servo-hydraulic material testing device. All tests were repeated after reactor irradiation to a fast neutron fluence of 1×1022 m-2 (E>0.1 MeV). In order to simulate the pulsed operation of ITER, tension-tension fatigue measurements were performed in the load controlled mode. Initial results show a high mechanical strength as expected from the high number of thin glass fiber layers, and an excellent homogeneity of the material.
Formative Assessment in Mathematics for Engineering Students
ERIC Educational Resources Information Center
Ní Fhloinn, Eabhnat; Carr, Michael
2017-01-01
In this paper, we present a range of formative assessment types for engineering mathematics, including in-class exercises, homework, mock examination questions, table quizzes, presentations, critical analyses of statistical papers, peer-to-peer teaching, online assessments and electronic voting systems. We provide practical tips for the…
A Ghostly Symposium on the Value of the Arts.
ERIC Educational Resources Information Center
Music Educators Journal, 1978
1978-01-01
In mock interviews with Mark Twain, Oscar Wilde, Plato, and George Santayana, the value of the arts in education is discussed. The author suggests this mock interview technique as a method for teaching other topics. (KC)
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023636 (4 Feb. 2010) --- NASA astronaut Tim Kopra, STS-133 mission specialist, participates in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center.
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023637 (4 Feb. 2010) --- NASA astronaut Alvin Drew, STS-133 mission specialist, participates in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center.
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023639 (4 Feb. 2010) --- NASA astronaut Steve Lindsey, STS-133 commander, participates in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center.
NASA Astrophysics Data System (ADS)
Hirai, T.; Bao, L.; Barabash, V.; Chappuis, Ph; Eaton, R.; Escourbiac, F.; Giqcuel, S.; Merola, M.; Mitteau, R.; Raffray, R.; Linke, J.; Loewenhoff, Th; Pintsuk, G.; Wirtz, M.; Boomstra, D.; Magielsen, A.; Chen, J.; Wang, P.; Gervash, A.; Safronov, V.
2016-02-01
ITER first wall (FW) panels are irradiated by energetic neutrons during the nuclear phase. Thus, an irradiation and high heat flux testing programme is undertaken by the ITER organization in order to evaluate the effects of neutron irradiation on the performance of enhanced heat flux (EHF) FW components. The test campaign includes neutron irradiation (up to 0.6-0.8 dpa at 200 °C-250 °C) of mock-ups that are representative of the final EHF FW panel design, followed by thermal fatigue tests (up to 4.7 MW m-2). Mock-ups were manufactured by the same manufacturing process as proposed for the series production. After a pre-irradiation thermal screening, eight mock-ups will be selected for the irradiation campaigns. This paper reports the preparatory work of HHF tests and neutron irradiation, assessment results as well as a brief description of mock-up manufacturing and inspection routes.
Development of inert density mock materials for HMX
Yeager, John D.; Higginbotham Duque, Amanda L.; Shorty, Marvin; ...
2017-09-22
Inert surrogates or mocks for high explosives are commonly used in place of the real material for complex experiments or in situations where safety is a concern. We tested several materials as potential mocks for HMX in terms of density, thermal stability, and processability. Selection criteria were developed and a literature search was conducted primarily using the Cambridge Structural Database. Moreover, out of over 200 potentially acceptable materials, six were chosen for crystallization experiments and a suite of analytical characterization. Of these six, 5-iodo-2'-deoxyuridine, N,N'-bis(2,3,4,5,6-pentafluorophenyl)oxamide, and 2,3,4,5,6-pentafluorobenzamide all were found to be thermally stable at 150°C, matched HMX density asmore » a pressed pellet, and could be crystallized to appropriate particle sizes. These three materials are considered suitable inert density mocks for HMX and will be the subject of future testing.« less
Ng, Boon C.; Timms, Daniel; Cohn, William E.
2018-01-01
Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9–15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states. PMID:29677212
NASA Astrophysics Data System (ADS)
ZuHone, J. A.; Kowalik, K.; Öhman, E.; Lau, E.; Nagai, D.
2018-01-01
We present the “Galaxy Cluster Merger Catalog.” This catalog provides an extensive suite of mock observations and related data for N-body and hydrodynamical simulations of galaxy cluster mergers and clusters from cosmological simulations. These mock observations consist of projections of a number of important observable quantities in several different wavebands, as well as along different lines of sight through each simulation domain. The web interface to the catalog consists of easily browsable images over epoch and projection direction, as well as download links for the raw data and a JS9 interface for interactive data exploration. The data are presented within a consistent format so that comparison between simulations is straightforward. All of the data products are provided in the standard Flexible Image Transport System file format. The data are being stored on the yt Hub (http://hub.yt), which allows for remote access and analysis using a Jupyter notebook server. Future versions of the catalog will include simulations from a number of research groups and a variety of research topics related to the study of interactions of galaxy clusters with each other and with their member galaxies. The catalog is located at http://gcmc.hub.yt.
Mobile System for Precise Aero Delivery with Global Reach Network Capability
2009-08-30
No intention / need for taking advantage of networking with other agents. The Atair’s Onyx Micro Light ( Onyx ML) delivery system (www.atair.com... onyx ) (Fig.9a) is a precision airdrop system designed to address the requirements of the Joint Precision Airdrop System MLW (JPADS-MLW) system of the...autonomous powered paraglider (LEAPP) developed under contract with DARPA (Fig.9b). a) b) Fig. 9. Onyx ML with mock sensor payload release
An architecture for rapid prototyping of control schemes for artificial ventricles.
Ficola, Antonio; Pagnottelli, Stefano; Valigi, Paolo; Zoppitelli, Maurizio
2004-01-01
This paper presents an experimental system aimed at rapid prototyping of feedback control schemes for ventricular assist devices, and artificial ventricles in general. The system comprises a classical mock circulatory system, an actuated bellow-based ventricle chamber, and a software architecture for control schemes implementation and experimental data acquisition, visualization and storing. Several experiments have been carried out, showing good performance of ventricular pressure tracking control schemes.
Program Spotlight: CURE Scholars Participate in Annual Mock Grant Review
As part of its 2015 Professional Development Workshop, CRCHD held a mock review session for CURE scholars, trainees, and investigators to enhance their understanding of the grant review process and provide insight on successful grant applications.
NASA Astrophysics Data System (ADS)
Heiselman, Jon S.; Collins, Jarrod A.; Clements, Logan W.; Weis, Jared A.; Simpson, Amber L.; Geevarghese, Sunil K.; Jarnagin, William R.; Miga, Michael I.
2017-03-01
In order to rigorously validate techniques for image-guided liver surgery (IGLS), an accurate mock representation of the intraoperative surgical scene with quantifiable localization of subsurface targets would be highly desirable. However, many attempts to reproduce the laparoscopic environment have encountered limited success due to neglect of several crucial design aspects. The laparoscopic setting is complicated by factors such as gas insufflation of the abdomen, changes in patient orientation, incomplete organ mobilization from ligaments, and limited access to organ surface data. The ability to accurately represent the influences of anatomical changes and procedural limitations is critical for appropriate evaluation of IGLS methodologies such as registration and deformation correction. However, these influences have not yet been comprehensively integrated into a platform usable for assessment of methods in laparoscopic IGLS. In this work, a mock laparoscopic liver simulator was created with realistic ligamenture to emulate the complexities of this constrained surgical environment for the realization of laparoscopic IGLS. The mock surgical system reproduces an insufflated abdominal cavity with dissectible ligaments, variable levels of incline matching intraoperative patient positioning, and port locations in accordance with surgical protocol. True positions of targets embedded in a tissue-mimicking phantom are measured from CT images. Using this setup, image-to-physical registration accuracy was evaluated for simulations of laparoscopic right and left lobe mobilization to assess rigid registration performance under more realistic laparoscopic conditions. Preliminary results suggest that non-rigid organ deformations and the region of organ surface data collected affect the ability to attain highly accurate registrations in laparoscopic applications.
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023629 (4 Feb. 2010) --- NASA astronauts Michael Barratt and Nicole Stott, both STS-133 mission specialists, participate in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center.
Zheng, Luyu; Zhang, Weiyi; Jiang, Miao; Zhang, Huarong; Xiong, Fei; Yu, Yang; Chen, Meijuan; Zhou, Jing; Dai, Xiaoming; Jiang, Ming; Wang, Mingyan; Cheng, Ge; Duan, Jinao; Yu, Wei; Lin, Biaoyang; Fu, Haian; Zhang, Xu
2013-01-01
Many traditional Chinese medicine (TCM) formulae have been used in cancer therapy. The JIN formula is an ancient herbal formula recorded in the classic TCM book Jin Kui Yao Lue (Golden Chamber). The JIN formula significantly delayed the growth of subcutaneous human H460 xenografted tumors in vivo compared with the growth of mock controls. Gene array analysis of signal transduction in cancer showed that the JIN formula acted on multiple targets such as the mitogen-activated protein kinase, hedgehog, and Wnt signaling pathways. The coformula treatment of JIN and diamminedichloroplatinum (DDP) affected the stress/heat shock pathway. Proteomic analysis showed 36 and 84 differentially expressed proteins between the mock and DDP groups and between the mock and JIN groups, respectively. GoMiner analysis revealed that the differentially expressed proteins between the JIN and mock groups were enriched during cellular metabolic processes, and so forth. The ones between the DDP and mock groups were enriched during protein-DNA complex assembly, and so forth. Most downregulated proteins in the JIN group were heat shock proteins (HSPs) such as HSP90AA1 and HSPA1B, which could be used as markers to monitor responses to the JIN formula therapy. The mechanism of action of the JIN formula on HSP proteins warrants further investigation. PMID:24066008
Boehler, Margaret L; Schwind, Cathy J; Markwell, Stephen J; Minter, Rebecca M
2017-01-01
Answering pages from nurses about patients in need of immediate attention is one of the most difficult challenges a resident faces during their first days as a physician. A Mock Page program has been developed and adopted into a national surgical resident preparatory curriculum to prepare senior medical students for this important skill. The purpose of this study is to assess standardized mock page cases as a valid construct to assess clinical decision making and interprofessional communication skills. Mock page cases (n = 16) were administered to 213 senior medical students from 12 medical schools participating in a national surgical resident preparatory curriculum in 2013 and 2014. Clinical decision making and interprofessional communication were measured by case-specific assessments evaluating these skills which have undergone rigorous standard-setting to determine pass/fail cut points. Students' performance improved in general for both communication and clinical decision making over the 4-week course. Cases have been identified that seem to be best suited for differentiating high- from low-performing students. Chest pain, pulmonary embolus, and mental status change cases posed the greatest difficulty for student learners. Simulated mock pages demonstrate an innovative technique for training students in both effective interprofessional communication and management of common postoperative conditions they will encounter as new surgical interns.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muscara, Joseph; Kupperman, David S.; Bakhtiari, Sasab
2002-07-01
This paper discusses round-robin exercises using the NRC steam generator (SG) mock-up at Argonne National Laboratory to assess inspection reliability. The purpose of the round robins was to assess the current reliability of SG tubing inservice inspection, determine the probability of detection (POD) as function of flaw size or severity, and assess the capability for sizing of flaws. For the round robin and subsequent evaluation completed in 2001, eleven teams participated. Bobbin and rotating coil mock-up data collected by qualified industry personnel were evaluated. The mock-up contains hundreds of cracks and simulations of artifacts such as corrosion deposits and tubemore » support plates that make detection and characterization of cracks more difficult in operating steam generators than in most laboratory situations. An expert Task Group from industry, Argonne National Laboratory, and the NRC have reviewed the signals from the laboratory-grown cracks used in the mock-up to ensure that they provide reasonable simulations of those obtained in the field. The mock-up contains 400 tube openings. Each tube contains nine 22.2-mm (7/8-in.) diameter, 30.5-cm (1-ft) long, Alloy 600 test sections. The flaws are located in the tube sheet near the roll transition zone (RTZ), in the tube support plate (TSP), and in the free-span. The flaws are primarily intergranular stress corrosion cracks (axial and circumferential, ID and OD) though intergranular attack (IGA) wear and fatigue cracks are also present, as well as cracks in dents. In addition to the simulated tube sheet and TSP the mock-up has simulated sludge and magnetite deposits. A multiparameter eddy current algorithm, validated for mock-up flaws, provided a detailed isometric plot for every flaw and was used to establish the reference state of defects in the mock-up. The detection results for the 11 teams were used to develop POD curves as a function of maximum depth, voltage and the parameter m p, for the various types of flaws. The POD curves were represented as linear logistic curves, and the curve parameters were determined by the method of Maximum Likelihood. The effect of both statistical uncertainties inherent in sampling from distributions and the uncertainties due to errors in the estimates of maximum depth and m p was investigated. The 95% one-sided confidence limits (OSL), which include errors in maximum depth estimates, are presented along with the POD curves. For the second round robin a reconfigured mock-up is being used to evaluate the effectiveness of eddy current array probes. The primary emphasis is on the X-Probe. Progress with the X-Probe round robin is discussed in this paper. (authors)« less
Teaching Strategy. Tort Law and the Civil Jury.
ERIC Educational Resources Information Center
Pittman, Keith A.
1997-01-01
Presents a lesson plan that introduces students to the tort system of law and the responsibilities of the civil jury. The lesson involves student research and a mock jury trial establishing legal responsibility for a fatal automobile accident. Includes a list of objectives, classroom procedures, and handouts on jury deliberations. (MJP)
Preparing Your Staff for Emergencies.
ERIC Educational Resources Information Center
Maurer-Starks, Suanne
2003-01-01
Camps should have emergency protocols in place and involve appropriate personnel in their development. Staff should be certified in first aid and CPR, a recordkeeping system should be established, and mock emergencies should be practiced during staff orientation. It may also be advisable to involve campers in practice situations. First aid/CPR…
STS-99 crewmembers train in orbiter mock-up
1999-08-24
S99-10568 (24 August 1999) --- Astronaut Janet L. Kavandi, mission specialist, participates in a training exercise in preparation for her upcoming flight aboard the Space Shuttle Endeavour. She is on the mid deck of one of the shuttle trainers in the Johnson Space Center's Systems Integration Facility.
Locomotive cab design development. volume 2 : operator's manual - Interim Report
DOT National Transportation Integrated Search
1976-10-01
Locomotive Cab 913 designed as a result of Contract DOT-TSC- 913 has been built as a hard mock-up. This Operator's Manual is to familiarize the user with the mock-up. Normal and emergency procedures and cab facilities are described.
STS-133 crew during SSMTF ISS EVA P/P training
2010-03-29
JSC2010-E-044343 (29 March 2010) --- NASA astronaut Alvin Drew, STS-133 mission specialist, participates in a training session in an International Space Station mock-up/trainer in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center.
Evacuation tests from an SST mock-up.
DOT National Transportation Integrated Search
1970-12-01
A comparative study of passenger flow rates through Type I and Type A aircraft door exits was made with two 280-passenger groups from the full-scale Lockheed Supersonic Transport mock-up, mounted in a belly-landing attitude. : The first load of 280 p...
The Scientific Program of the U.S. Naval Research Laboratory
1958-07-01
systems, using mock-ups and simulated inputs. (2) Experimental determination of the quantitative parameters of systems, such as data-handling ability, time...naval service of equipment on ships, planes, and mis- siles are recorded, analyzed, and simulated . Methods are developed for the improve- ment of...H01 - NUCLEAR CONSTITUENTS AND STRUCTURE Theoretical and experimental studies concerned with elementary particles , field theory, nuclear structure
Mock ECHO: A Simulation-Based Medical Education Method.
Fowler, Rebecca C; Katzman, Joanna G; Comerci, George D; Shelley, Brian M; Duhigg, Daniel; Olivas, Cynthia; Arnold, Thomas; Kalishman, Summers; Monnette, Rebecca; Arora, Sanjeev
2018-04-16
This study was designed to develop a deeper understanding of the learning and social processes that take place during the simulation-based medical education for practicing providers as part of the Project ECHO® model, known as Mock ECHO training. The ECHO model is utilized to expand access to care of common and complex diseases by supporting the education of primary care providers with an interprofessional team of specialists via videoconferencing networks. Mock ECHO trainings are conducted through a train the trainer model targeted at leaders replicating the ECHO model at their organizations. Trainers conduct simulated teleECHO clinics while participants gain skills to improve communication and self-efficacy. Three focus groups, conducted between May 2015 and January 2016 with a total of 26 participants, were deductively analyzed to identify common themes related to simulation-based medical education and interdisciplinary education. Principal themes generated from the analysis included (a) the role of empathy in community development, (b) the value of training tools as guides for learning, (c) Mock ECHO design components to optimize learning, (d) the role of interdisciplinary education to build community and improve care delivery, (e) improving care integration through collaboration, and (f) development of soft skills to facilitate learning. Mock ECHO trainings offer clinicians the freedom to learn in a noncritical environment while emphasizing real-time multidirectional feedback and encouraging knowledge and skill transfer. The success of the ECHO model depends on training interprofessional healthcare providers in behaviors needed to lead a teleECHO clinic and to collaborate in the educational process. While building a community of practice, Mock ECHO provides a safe opportunity for a diverse group of clinician experts to practice learned skills and receive feedback from coparticipants and facilitators.
Pica, Emily; Sheahan, Chelsea; Pozzulo, Joanna
2017-06-01
There have been several recent, high-profile cases in the media that have shed light on the perceived leniency in sentencing defendants in sexual assault cases. In a number of these cases, the defendant was well known within their community (e.g., Brock Turner; People v. Turner) or nationally (e.g., Ghomeshi; R v. Ghomeshi). The purpose of this study was to examine how the social status of the defendant (low vs. high), victim social status (low vs. high), victim gender (male vs. female), and the reason the victim was unconscious during the assault (consuming alcohol vs. consuming cold medicine) influenced mock jurors' decisions in a sexual assault case. Mock jurors ( N = 489) read a mock trial transcript depicting an alleged sexual assault. Mock jurors were asked to render a dichotomous verdict, continuous guilt rating, and rate their perceptions of the victim and defendant. There was no influence of the variables on mock jurors' dichotomous verdicts; however, social status influenced guilt ratings. There also was a combined influence of the defendant's social status and the reason the victim was unconscious such that when the defendant was described as low status, and the victim was unconscious due to alcohol consumption, the defendant received higher guilt ratings compared with when the victim was unconscious due to cold medicine. Moreover, the victim was perceived as having more control over the situation when the defendant was the star quarterback (i.e., high status), the victim was female, and she was unconscious due to alcohol consumption compared with cold medicine. These results suggest that victims may be blamed based on their perceived social status and other factors that may have influenced their control over the sexual assault, such as alcohol consumption.
Aboulian, Armen; Schwartz, Samuel; Kaji, Amy H; de Virgilio, Christian
2010-01-01
The objective of the study was to investigate the value of an educational program instituted in our general surgery residency training in preparation for the American Board of Surgery (ABS) Certifying Examination (CE). From 2006 to 2009, a series of public mock oral examinations were administered by the program director to PGY residents 4 through 6 on a variety of surgery topics in front of all residents, faculty, and medical students. Anonymous surveys (5-point Likert scale) were collected from both the examinees and the audience to determine the perceived utility of the mock oral. Performance on the ABS CE for residents who partook in the program was compared with the five previous years. The study was undertaken at Harbor-University of California at Los Angeles (UCLA) Medical Center, a level I trauma center in Los Angeles County. Overall 201 surveys were collected, 170 from the audience and 31 from examinees. The surveys demonstrated a high and equal level of satisfaction for both examinees (4.8) and the audience (4.6, p = 0.12). First-time pass rates on the ABS CE increased from 88% (38/43) before the public mock oral to 100% (19/19) after the mock oral (p = 0.3). The mock oral examination, which is conducted in a conference format in front of an audience of faculty and trainees, is a valuable educational tool as it helps both the examinee and the audience in preparation for the ABS CE. In addition, it has an educational value for those who are not preparing for the CE as it is perceived to expand surgical knowledge. Copyright 2010 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
A fungal mock community control for amplicon sequencing experiments
USDA-ARS?s Scientific Manuscript database
Microbial ecology has been profoundly advanced by the ability to profile complex microbial communities by sequencing of marker genes amplified from environmental samples. However, inclusion of appropriate controls is vital to revealing the limitations and biases of this technique. “Mock community” s...
Mock climate summit: teaching and assessing learning
NASA Astrophysics Data System (ADS)
Schweizer, D.; Gautier, C.; Bazerman, C.
2003-04-01
This paper will demonstrate the effectiveness of a Mock Climate Summit as a pedagogical approach for teaching the science and policy aspects of global climate change. The Mock Climate Summit is a student-centered course simulating the Conference of the Parties (COP) where international environmental protocols are negotiated. Compared to traditional lecture-based methods common in the geoscience classroom, the Mock Climate Summit uses negotiations and arguments to teach the interactions between these two “spheres” and demonstrate the depth and breadth of these interactions. Through a detailed assessment of students’ dialogue transcribed from video and audio tapes, we found that the nature of the student dialogue matures rapidly as they are given multiple opportunities to present, negotiate and argue a specific topic. Students’ dialogue progress from hypothetical (what-if) scenarios to action-oriented scenarios and implementation plans. The progression of the students’ dialogue shows increased comfort with the communities’ discourse as they take ownership of the point-of-view associated with their assumed roles.
Mock Climate Summit: Teaching and Assessing Learning
NASA Astrophysics Data System (ADS)
Schweizer, D.; Gautier, C.; Bazerman, C.
2003-04-01
This paper will demonstrate the effectiveness of a Mock Climate Summit as a pedagogical for teaching the science and policy aspects of global climate change. The Mock Climate Summit is a student-centered course simulating the Conference of the Parties (COP) where international environmental protocols are negotiated. Compared to traditional lecture-based methods common in the geoscience classroom, the Mock Climate Summit uses negotiations and arguments to teach the interactions between these two "spheres" and demonstrate the depth and breadth of these interactions. Through a detailed assessment of students' dialogue transcribed from video and audio tapes, we found that the nature of the student dialogue matures rapidly as they are given multiple opportunities to present, negotiate and argue a specific topic. Students' dialogue progress from hypothetical (what-if) scenarios to action-oriented scenarios and implementation plans. The progression of the students' dialogue shows increased comfort with the communities' discourse as they take ownership of the point-of-view associated with their assumed roles.
Winograd, Michael R; Rosenfeld, J Peter
2014-12-01
In P300-Concealed Information Tests used with mock crime scenarios, the amount of detail revealed to a participant prior to the commission of the mock crime can have a serious impact on a study's validity. We predicted that exposure to crime details through instructions would bias detection rates toward enhanced sensitivity. In a 2 × 2 factorial design, participants were either informed (through mock crime instructions) or naïve as to the identity of a to-be-stolen item, and then either committed (guilty) or did not commit (innocent) the crime. Results showed that prior knowledge of the stolen item was sufficient to cause 69% of innocent-informed participants to be incorrectly classified as guilty. Further, we found a trend toward enhanced detection rate for guilty-informed participants over guilty-naïve participants. Results suggest that revealing details to participants through instructions biases detection rates in the P300-CIT toward enhanced sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bautista, Julian E.; Busca, Nicolas G.; Bailey, Stephen
We describe mock data-sets generated to simulate the high-redshift quasar sample in Data Release 11 (DR11) of the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). The mock spectra contain Lyα forest correlations useful for studying the 3D correlation function including Baryon Acoustic Oscillations (BAO). They also include astrophysical effects such as quasar continuum diversity and high-density absorbers, instrumental effects such as noise and spectral resolution, as well as imperfections introduced by the SDSS pipeline treatment of the raw data. The Lyα forest BAO analysis of the BOSS collaboration, described in Delubac et al. 2014, has used these mock data-sets to developmore » and cross-check analysis procedures prior to performing the BAO analysis on real data, and for continued systematic cross checks. Tests presented here show that the simulations reproduce sufficiently well important characteristics of real spectra. These mock data-sets will be made available together with the data at the time of the Data Release 11.« less
Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T
2000-04-01
Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.
Expression Dynamics of Innate Immunity in Influenza Virus-Infected Swine
Montoya, María; Foni, Emanuela; Solórzano, Alicia; Razzuoli, Elisabetta; Baratelli, Massimiliano; Bilato, Dania; Córdoba, Lorena; del Burgo, Maria Angeles Martín; Martinez, Jorge; Martinez-Orellana, Pamela; Chiapponi, Chiara; Perlin, David S.; del Real, Gustavo; Amadori, Massimo
2017-01-01
The current circulating swine influenza virus (IV) subtypes in Europe (H1N1, H1N2, and H3N2) are associated with clinical outbreaks of disease. However, we showed that pigs could be susceptible to other IV strains that are able to cross the species barrier. In this work, we extended our investigations into whether different IV strains able to cross the species barrier might give rise to different innate immune responses that could be associated with pathological lesions. For this purpose, we used the same samples collected in a previous study of ours, in which healthy pigs had been infected with a H3N2 Swine IV and four different H3N8 IV strains circulating in different animal species. Pigs had been clinically inspected and four subjects/group were sacrificed at 3, 6, and 21 days post infection. In the present study, all groups but mock exhibited antibody responses to IV nucleoprotein protein. Pulmonary lesions and high-titered viral replication were observed in pigs infected with the swine-adapted virus. Interestingly, pigs infected with avian and seal H3N8 strains also showed moderate lesions and viral replication, whereas equine and canine IVs did not cause overt pathological signs, and replication was barely detectable. Swine IV infection induced interferon (IFN)-alpha and interleukin-6 responses in bronchoalveolar fluids (BALF) at day 3 post infection, as opposed to the other non-swine-adapted virus strains. However, IFN-alpha responses to the swine-adapted virus were not associated with an increase of the local, constitutive expression of IFN-alpha genes. Remarkably, the Equine strain gave rise to a Serum Amyloid A response in BALF despite little if any replication. Each virus strain could be associated with expression of cytokine genes and/or proteins after infection. These responses were observed well beyond the period of virus replication, suggesting a prolonged homeostatic imbalance of the innate immune system. PMID:28484702
Library Circulation Systems -- An Overview.
ERIC Educational Resources Information Center
Surace, Cecily J.
The model circulation system outlined is an on-line real time system in which the circulation file is created from the shelf list and the terminal inquiry system includes the capability to query and browse through the bibliographic system and the circulation subsystem together to determine the availability for circulation of specific documents, or…
Kosaka, Ryo; Fukuda, Kyohei; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi
2013-01-01
In order to monitor the condition of a patient using a left ventricular assist system (LVAS), blood flow should be measured. However, the reliable determination of blood-flow rate has not been established. The purpose of the present study is to develop a noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump. The flow meter uses the centrifugal force generated by the flow rate in the curved cannula. Two strain gauges served as sensors. The first gauges were attached to the curved area to measure static pressure and centrifugal force, and the second gauges were attached to straight area to measure static pressure. The flow rate was determined by the differences in output from the two gauges. The zero compensation was constructed based on the consideration that the flow rate could be estimated during the initial driving condition and the ventricular suction condition without using the flow meter. A mock circulation loop was constructed in order to evaluate the measurement performance of the developed flow meter with zero compensation. As a result, the zero compensation worked effectively for the initial calibration and the zero-drift of the measured flow rate. We confirmed that the developed flow meter using a curved cannula with zero compensation was able to accurately measure the flow rate continuously and noninvasively.
The Trial of Napoleon: A Case Study for Using Mock Trials.
ERIC Educational Resources Information Center
MacKay, Charles
2000-01-01
Describes a course entitled "The Trial of Napoleon Bonaparte" that focuses on a fictitious mock trial of Napoleon Bonaparte to answer the question: did Napoleon pervert or preserve the gain of the French Revolution? Discusses the strengths and weaknesses of the course. (CMK)
The Death's-Head Pin: Using a Mock Trial to Introduce the Cariboo Gold Rush.
ERIC Educational Resources Information Center
Hou, Charles
1983-01-01
The roles and procedures for holding a mock trial based on actual events that took place during the Canadian Cariboo gold rush are described. Intended for use with secondary history students, the trial can be conducted in one classroom period. (RM)
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023633 (4 Feb. 2010) --- NASA astronaut Nicole Stott (right), STS-133 mission specialist, participates in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Instructors Shanna Andrew and James Gaustad assisted Stott.
ERIC Educational Resources Information Center
Clark, Carlton
2008-01-01
The mock research paper combines creative writing with academic writing and, in the process, breaks down that binary. This article describes a writing assignment that offers an introduction to the college research paper genre. This assignment helps students focus on crafting an argument and learning genre conventions while postponing until the…
Program Spotlight: CRCHD Mock Grant Review
The NCI Center to Reduce Cancer Health Disparities (CRCHD) held a Professional Development Workshop for its Continuing Umbrella of Research Experience (CURE) scholars on June 23-24, 2014, in Rockville, Maryland. As part of the workshop, attendees had an opportunity to observe and participate in a Mock Grant Review.
Soneral, Paula A. G.; Wyse, Sara A.
2017-01-01
Student-centered learning environments with upside-down pedagogies (SCALE-UP) are widely implemented at institutions across the country, and learning gains from these classrooms have been well documented. This study investigates the specific design feature(s) of the SCALE-UP classroom most conducive to teaching and learning. Using pilot survey data from instructors and students to prioritize the most salient SCALE-UP classroom features, we created a low-tech “Mock-up” version of this classroom and tested the impact of these features on student learning, attitudes, and satisfaction using a quasi-experimental setup. The same instructor taught two sections of an introductory biology course in the SCALE-UP and Mock-up rooms. Although students in both sections were equivalent in terms of gender, grade point average, incoming ACT, and drop/fail/withdraw rate, the Mock-up classroom enrolled significantly more freshmen. Controlling for class standing, multiple regression modeling revealed no significant differences in exam, in-class, preclass, and Introduction to Molecular and Cellular Biology Concept Inventory scores between the SCALE-UP and Mock-up classrooms. Thematic analysis of student comments highlighted that collaboration and whiteboards enhanced the learning experience, but technology was not important. Student satisfaction and attitudes were comparable. These results suggest that the benefits of a SCALE-UP experience can be achieved at lower cost without technology features. PMID:28213582
STS-135 crew during Ingress/Egress Timeline training in building 9NW space station mockups
2011-04-29
JSC2011-E-043875 (29 April 2011) --- NASA astronaut Rex Walheim, STS-135 mission specialist, participates in an EVA Thermal Protection System (TPS) overview training session in the TPS/Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Photo credit: NASA
STS-135 Escape System Refresher training and Stowage Review Training
2011-06-29
JSC2011-E-060759 (29 June 2011) --- NASA astronaut Sandy Magnus, STS-135 mission specialist, participates in a training session in the crew compartment trainer (CCT-2) in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Here, she is being briefed on the escape pole. Photo credit: NASA
Polysensory Learning through Multi-Media Instruction in Trade and Technical Education.
ERIC Educational Resources Information Center
Allen, David; And Others
This report explains a teaching system designed to stimulate polysensory learning by use of multi-media instructional materials, which use as many of the physical senses as practical to augment traditional instruction. They include motion pictures, filmstrips, audio tapes, models, mock-ups, etc., according to school facilities and course needs.…
What Is John Dewey Doing in "To Kill a Mockingbird"?
ERIC Educational Resources Information Center
Frank, Jeff
2015-01-01
Harper Lee's novel "To Kill a Mockingbird" is taught in countless public schools and is beloved by many teachers and future teachers. Embedded within this novel--interestingly--is a strong criticism of an approach to education mockingly referred to as the "Dewey Decimal System." In this essay I explore Lee's criticism of…
Instrumentation to Record Evoked Potentials for Closed-Loop Control of Deep Brain Stimulation
Kent, Alexander R.; Grill, Warren M.
2012-01-01
Closed-loop deep brain stimulation (DBS) systems offer promise in relieving the clinical burden of stimulus parameter selection and improving treatment outcomes. In such a system, a feedback signal is used to adjust automatically stimulation parameters and optimize the efficacy of stimulation. We explored the feasibility of recording electrically evoked compound action potentials (ECAPs) during DBS for use as a feedback control signal. A novel instrumentation system was developed to suppress the stimulus artifact and amplify the small magnitude, short latency ECAP response during DBS with clinically relevant parameters. In vitro testing demonstrated the capabilities to increase the gain by a factor of 1,000x over a conventional amplifier without saturation, reduce distortion of mock ECAP signals, and make high fidelity recordings of mock ECAPs at latencies of only 0.5 ms following DBS pulses of 50 to 100 μs duration. Subsequently, the instrumentation was used to make in vivo recordings of ECAPs during thalamic DBS in cats, without contamination by the stimulus artifact. The signal characteristics were similar across three experiments, suggesting common neural activation patterns. The ECAP recordings enabled with this novel instrumentation may provide insight into the type and spatial extent of neural elements activated during DBS, and could serve as feedback control signals for closed-loop systems. PMID:22255894
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, C.V.; Lockwood, G.J.; Normann, R.A.
1999-06-01
The Environmental Measurement-While-Drilling (EMWD) system and Horizontal Directional Drilling (HDD) were successfully demonstrated at the Mock Tank Leak Simulation Site and the Drilling Technology Test Site, Hanford, Washington. The use of directional drilling offers an alternative to vertical drilling site characterization. Directional drilling can develop a borehole under a structure, such as a waste tank, from an angled entry and leveling off to horizontal at the desired depth. The EMWD system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drill bit data during drilling operations. The technology demonstration consisted ofmore » the development of one borehole under a mock waste tank at a depth of {approximately} {minus}8 m ({minus}27 ft.), following a predetermined drill path, tracking the drill path to within a radius of {approximately}1.5 m (5 ft.), and monitoring for zones of radiological activity using the EMWD system. The purpose of the second borehole was to demonstrate the capability of drilling to a depth of {approximately} {minus}21 m ({minus}70 ft.), the depth needed to obtain access under the Hanford waste tanks, and continue drilling horizontally. This report presents information on the HDD and EMWD technologies, demonstration design, results of the demonstrations, and lessons learned.« less
An overview of the second round of the Mock LISA Data Challenges
NASA Astrophysics Data System (ADS)
Arnaud, K. A.; Babak, S.; Baker, J. G.; Benacquista, M. J.; Cornish, N. J.; Cutler, C.; Finn, L. S.; Larson, S. L.; Littenberg, T.; Porter, E. K.; Vallisneri, M.; Vecchio, A.; Vinet, J.-Y.; Data Challenge Task Force, The Mock LISA
2007-10-01
The Mock Data Challenges (MLDCs) have the dual purpose of fostering the development of LISA data-analysis tools and capabilities and of demonstrating the technical readiness already achieved by the gravitational-wave community in distilling a rich science payoff from the LISA data. The first round of MLDCs has just been completed and the second-round data sets are being released shortly after this workshop. The second-round data sets contain radiation from an entire Galactic population of stellar-mass binary systems, from massive-black-hole binaries, and from extreme-mass-ratio inspirals. These data sets are designed to capture much of the complexity that is expected in the actual LISA data, and should provide a fairly realistic setting to test advanced data-analysis techniques, and in particular the global aspect of the analysis. Here we describe the second round of MLDCs and provide details about its implementation.
Holomorphic projections and Ramanujan’s mock theta functions
Imamoğlu, Özlem; Raum, Martin; Richter, Olav K.
2014-01-01
We use spectral methods of automorphic forms to establish a holomorphic projection operator for tensor products of vector-valued harmonic weak Maass forms and vector-valued modular forms. We apply this operator to discover simple recursions for Fourier series coefficients of Ramanujan’s mock theta functions. PMID:24591582
Incorporating Argumentation through Forensic Science
ERIC Educational Resources Information Center
Wheeler, Lindsay B.; Maeng, Jennifer L.; Smetana, Lara K.
2014-01-01
This article outlines how to incorporate argumentation into a forensic science unit using a mock trial. Practical details of the mock trial include: (1) a method of scaffolding students' development of their argument for the trial, (2) a clearly outlined set of expectations for students during the planning and implementation of the mock…
A Learner-Centred Mock Conference Model for Undergraduate Teaching
ERIC Educational Resources Information Center
Kumar, Kari
2011-01-01
This essay describes a mock conference model of instruction suitable for use in undergraduate teaching, and which adheres to principles of learner-centred instruction and universal design for learning. A staged process of learner preparation for the conference is outlined, and student and instructor roles during preconference, conference, and…
Best Practices in Preparing Students for Mock Interviews
ERIC Educational Resources Information Center
Hansen, Katharine; Oliphant, Gary C.; Oliphant, Becky J.; Hansen, Randall S.
2009-01-01
Studies have shown the importance of employment interview preparation in boosting the confidence and performance of students and jobseekers when they interview. This article reviews several techniques for preparing students for mock job interviews and, hence, actual job interviews. For instructors who would like to enhance the learning value of…
Bahi, Amine; Al Mansouri, Shamma; Al Maamari, Elyazia
2016-10-01
Anxiety is believed to influence ethanol use human in alcoholics. Studies using laboratory animals suggested an interaction between oxytocin and the behavioral effects of ethanol. Our previous study implicated a potential role for the oxytocin receptor (OxtR) in regulating ethanol-conditioned place preference. Here, we examined anxiety and the behavioral responses to ethanol in C57BL/6 mice stereotaxically injected in the nucleus accumbens (NAcc) with lentiviral vectors expressing an empty vector (Mock) or the OxtR cDNA. For anxiety we used the elevated-plus maze, the open-field and the marble-burying tests and for ethanol we used the two-bottle choice paradigm, the wire-hanging and ethanol-induced loss-of-righting-reflex tests. We found that, compared to Mock, OxtR overexpression led to anxiolytic-like behavior without altering spontaneous locomotor activity. Most importantly, we found that, relative to Mock controls, increased expression of the OxtR in the NAcc led to decreased ethanol consumption and preference in the two-bottle choice protocol and increased resistance to ethanol-induced sedation. We also compared the consequence of OxtR modulation on the consumption and preference of saccharin and quinine and found that the two experimental groups did not differ for any tastant. These results provide further evidence that the oxytocin system contributes to the regulation of ethanol drinking and sensitivity and position OxtR as a central molecular mediator of ethanol's effects within the mesolimbic system. Taken together, the current findings suggest that OxtR manipulation may be a relevant strategy to address ethanol use disorders. Copyright © 2016 Elsevier Inc. All rights reserved.
Sauer, I M; Frank, J; Spiegelberg, A; Bücherl, E S
2000-01-01
A new electromechanical energy converting system has been developed to yield an efficient and durable orthotopic total artificial heart (TAH). The energy converter we developed transforms the unidirectional rotational motion of the motor into a longitudinal forward-reverse movement of an internal geared oval, linked directly to pusher plates on both sides. To ensure a permanent positive connection between the drive gear and the internally geared wheel, a ball bearing runs inside an oval shaped guide track. Motor, gear unit, and conical pusher plates are seated between alternately ejecting and filling ventricles. The unidirectional motion of the brushless DC motor affords easier motor control, reduces energy demand, and ensures longer life of the motor when compared with a bidirectional motion system. In vitro testing has been performed on a mock circulation loop. The overall system efficiency of the TAH Ovalis was 27-39% (mean, 36%) for the pump output range of 2-7 L/min. The maximum output of 7 L/min can be obtained with a pump rate of 130 min(-1) and an afterload pressure of 140 mm Hg. For an average sized human with a mean cardiac output of 6 L/min at a mean aortic pressure of 120 mm Hg, 5 watts of input power would be required. The size of the prototype is 560 cm3, the weight is 950 g. Our first in vitro studies demonstrated the excellent efficiency and pump performance of this new electromechanical energy converter. The results prove the feasibility of this new concept's use as an energy converter for a total artificial heart.
Death Certification Errors and the Effect on Mortality Statistics.
McGivern, Lauri; Shulman, Leanne; Carney, Jan K; Shapiro, Steven; Bundock, Elizabeth
Errors in cause and manner of death on death certificates are common and affect families, mortality statistics, and public health research. The primary objective of this study was to characterize errors in the cause and manner of death on death certificates completed by non-Medical Examiners. A secondary objective was to determine the effects of errors on national mortality statistics. We retrospectively compared 601 death certificates completed between July 1, 2015, and January 31, 2016, from the Vermont Electronic Death Registration System with clinical summaries from medical records. Medical Examiners, blinded to original certificates, reviewed summaries, generated mock certificates, and compared mock certificates with original certificates. They then graded errors using a scale from 1 to 4 (higher numbers indicated increased impact on interpretation of the cause) to determine the prevalence of minor and major errors. They also compared International Classification of Diseases, 10th Revision (ICD-10) codes on original certificates with those on mock certificates. Of 601 original death certificates, 319 (53%) had errors; 305 (51%) had major errors; and 59 (10%) had minor errors. We found no significant differences by certifier type (physician vs nonphysician). We did find significant differences in major errors in place of death ( P < .001). Certificates for deaths occurring in hospitals were more likely to have major errors than certificates for deaths occurring at a private residence (59% vs 39%, P < .001). A total of 580 (93%) death certificates had a change in ICD-10 codes between the original and mock certificates, of which 348 (60%) had a change in the underlying cause-of-death code. Error rates on death certificates in Vermont are high and extend to ICD-10 coding, thereby affecting national mortality statistics. Surveillance and certifier education must expand beyond local and state efforts. Simplifying and standardizing underlying literal text for cause of death may improve accuracy, decrease coding errors, and improve national mortality statistics.
Absolute determination of power density in the VVER-1000 mock-up on the LR-0 research reactor.
Košt'ál, Michal; Švadlenková, Marie; Milčák, Ján
2013-08-01
The work presents a detailed comparison of calculated and experimentally determined net peak areas of selected fission products gamma lines. The fission products were induced during a 2.5 h irradiation on the power level of 9.5 W in selected fuel pins of the VVER-1000 Mock-Up. The calculations were done with deterministic and stochastic (Monte Carlo) methods. The effects of different nuclear data libraries used for calculations are discussed as well. The Net Peak Area (NPA) may be used for the determination of fission density across the mock-up. This fission density is practically identical to power density. Copyright © 2013 Elsevier Ltd. All rights reserved.
Space station wardroom habitability and equipment study
NASA Technical Reports Server (NTRS)
Nixon, David; Miller, Christopher; Fauquet, Regis
1989-01-01
Experimental designs in life-size mock-up form for the wardroom facility for the Space Station Habitability Module are explored and developed. In Phase 1, three preliminary concepts for the wardroom configuration are fabricated and evaluated. In Phase 2, the results of Phase 1 are combined with a specific range of program design requirements to provide the design criteria for the fabrication of an innovative medium-fidelity mock-up of a wardrobe configuration. The study also focuses on the design and preliminary prototyping of selected equipment items including crew exercise compartments, a meal/meeting table and a portable workstation. Design criteria and requirements are discussed and documented. Preliminary and final mock-ups and equipment prototypes are described and illustrated.
Effects of Detail in Eyewitness Testimony on Decisions by Mock Jurors.
ERIC Educational Resources Information Center
Heath, Wendy P.; Grannemann, Bruce D.; Sawa, Stephanie E.; Hodge, Kristine M.
1997-01-01
Investigated the effects of the presence and typicality of detail in a witness' testimony on mock juror judgments. Results indicate that the presence of detail affected the ratings of witnesses. Atypical or typical detail provided by one witness, with no detail provided by the opposing witness, enhanced assessments of the former. (RJM)
The Implementation of Mock Negotiations in Teaching International Business Management.
ERIC Educational Resources Information Center
Raffield, Barney T., III
Mock negotiations are used as part of an undergraduate course in international business management at Lebanon Valley College (Pennsylvania) in order to introduce students to the process of negotiating for advantage in foreign countries and to emphasize the importance of an individual nation's customs, culture, and ways of transacting business in…
USDA-ARS?s Scientific Manuscript database
Alighting, settling and oviposition behavioral assays were conducted on Squash vein yellowing virus- (SqVYV-) infected and mock-inoculated squash and watermelon plants. Developmental time of immature stages, adult longevity, and fecundity were measured on SqVYV-infected and mock-inoculated squash p...
Mock Elections in Civic Education: A Space for Critical Democratic Citizenship Development
ERIC Educational Resources Information Center
De Groot, Isolde
2017-01-01
Purpose: Preparing citizens for participation in pluralist democracies also requires a type of citizenship education that fosters critical democratic citizenship (CDC). This study inquires into an educational activity with a long history in many EU-countries: mock elections. It explores the extent to which elements of CDC-literacy, competences and…
STS-133 crew during CCT II Flight Communications plan
2010-02-04
JSC2010-E-023632 (4 Feb. 2010) --- NASA astronauts Michael Barratt (left) and Nicole Stott, both STS-133 mission specialists, participate in training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. United Space Alliance instructor James Gaustad assisted Barratt and Stott.
Mock Trial: A Window to Free Speech Rights and Abilities
ERIC Educational Resources Information Center
Schwartz, Sherry
2010-01-01
This article provides some strategies to alleviate the current tensions between personal responsibility and freedom of speech rights in the public school classroom. The article advocates the necessity of making sure students understand the points and implications of the first amendment by providing a mock trial unit concerning free speech rights.…
Mock and National Examinations Correlations in a Health Information Associate Degree Program
ERIC Educational Resources Information Center
Jenkins, Neisa R.
2013-01-01
Students enrolled in associate degree programs face social and personal challenges that can affect their learning and assessment skills. Social and personal challenges such as unemployment rates, race, age, and gender may affect their employability. The purpose of this quantitative correlational study was to examine the mock and national…
Re-analysis of HCPB/HCLL Blanket Mock-up Experiments Using Recent Nuclear Data Libraries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondo, K., E-mail: keitaro.kondo@kit.edu; Fischer, U.; Klix, A.
2014-06-15
We have re-analysed the two breeding blankets experiments performed previously in the frame of the European fusion program on two mock-ups of the European Helium-Cooled-Lithiium Lead (HCLL) and Helium-Cooled-Pebble-Bed (HCPB) test blanket modules for ITER. The tritium production rate and the neutron and photon spectra measured in these mock-ups were compared with calculations using FENDL-3 Starter Library, release 4 and state-of-the-art nuclear data evaluations, JEFF-3.1.2, JENDL-4.0 and ENDF/B-VII.0. The tritium production calculated for the HCPB mock-up underestimates the experimental result by about 10%. The result calculated with FENDL-3/SLIB4 gives slightly smaller tritium production by 2% than the one with FENDL-2.1.more » The difference attributes to the slight modification of the total and elastic scattering cross section of Be. For the HCLL experiment, all libraries reproduce the experimental results well. FENDL-3/SLIB4 gives better result both for the measured spectra and the tritium production compared to FENDL-2.1.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernyk, Maksym; Croton, Darren J.; Tonini, Chiara
We introduce the Theoretical Astrophysical Observatory (TAO), an online virtual laboratory that houses mock observations of galaxy survey data. Such mocks have become an integral part of the modern analysis pipeline. However, building them requires expert knowledge of galaxy modeling and simulation techniques, significant investment in software development, and access to high performance computing. These requirements make it difficult for a small research team or individual to quickly build a mock catalog suited to their needs. To address this TAO offers access to multiple cosmological simulations and semi-analytic galaxy formation models from an intuitive and clean web interface. Results canmore » be funnelled through science modules and sent to a dedicated supercomputer for further processing and manipulation. These modules include the ability to (1) construct custom observer light cones from the simulation data cubes; (2) generate the stellar emission from star formation histories, apply dust extinction, and compute absolute and/or apparent magnitudes; and (3) produce mock images of the sky. All of TAO’s features can be accessed without any programming requirements. The modular nature of TAO opens it up for further expansion in the future.« less
A comparison of injection pain and postoperative pain of two intraosseous anesthetic techniques.
Gallatin, Juliane; Nusstein, John; Reader, Al; Beck, Mike; Weaver, Joel
2003-01-01
The purpose of this prospective, randomized, blinded study was to compare injection pain and postoperative pain of an apical primary X-Tip intraosseous technique to a coronal primary Stabident intraosseous technique in mandibular first molars. Using a repeated-measures design, 41 subjects randomly received 2 primary intraosseous injections at 2 separate appointments. Using a site distal to the mandibular first molar for both injections, the subjects received 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the X-Tip system using an apical location in alveolar mucosa or 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the Stabident system using a coronal location in attached gingiva. The pain of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain were recorded on a Heft-Parker visual analogue scale (VAS) scale for the 2 intraosseous systems. The results demonstrated that the apical primary X-Tip intraosseous technique was not statistically different (P > .05) from the coronal primary Stabident technique regarding pain ratings of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain (at the time subjective anesthesia wore off). However, on postoperative days 1 through 3, significantly (P < .05) more males experienced postoperative pain with the X-Tip system than with the Stabident system.
NASA Astrophysics Data System (ADS)
Faucher-Giguere, Claude-Andre
2016-10-01
HST has invested thousands of orbits to complete multi-wavelength surveys of high-redshift galaxies including the Deep Fields, COSMOS, 3D-HST and CANDELS. Over the next few years, JWST will undertake complementary, spatially-resolved infrared observations. Cosmological simulations are the most powerful tool to make detailed predictions for the properties of galaxy populations and to interpret these surveys. We will leverage recent major advances in the predictive power of cosmological hydrodynamic simulations to produce the first statistical sample of hundreds of galaxies simulated with 10 pc resolution and with explicit interstellar medium and stellar feedback physics proved to simultaneously reproduce the galaxy stellar mass function, the chemical enrichment of galaxies, and the neutral hydrogen content of galaxy halos. We will process our new set of full-volume cosmological simulations, called FIREBOX, with a mock imaging and spectral synthesis pipeline to produce realistic mock HST and JWST observations, including spatially-resolved photometry and spectroscopy. By comparing FIREBOX with recent high-redshift HST surveys, we will study the stellar build up of galaxies, the evolution massive star-forming clumps, their contribution to bulge growth, the connection of bulges to star formation quenching, and the triggering mechanisms of AGN activity. Our mock data products will also enable us to plan future JWST observing programs. We will publicly release all our mock data products to enable HST and JWST science beyond our own analysis, including with the Frontier Fields.
Evaluating lineup fairness: Variations across methods and measures.
Mansour, Jamal K; Beaudry, Jennifer L; Kalmet, Natalie; Bertrand, Michelle I; Lindsay, R C L
2017-02-01
Triers of fact sometimes consider lineup fairness when determining the suggestiveness of an identification procedure. Likewise, researchers often consider lineup fairness when comparing results across studies. Despite their importance, lineup fairness measures have received scant empirical attention and researchers inconsistently conduct and report mock-witness tasks and lineup fairness measures. We conducted a large-scale, online experiment (N = 1,010) to examine how lineup fairness measures varied with mock-witness task methodologies as well as to explore the validity and reliability of the measures. In comparison to descriptions compiled from multiple witnesses, when individual descriptions were presented in the mock-witness task, lineup fairness measures indicated a higher number of plausible lineup members but more bias toward the suspect. Target-absent lineups were consistently estimated to be fairer than target-present lineups-which is problematic because it suggests that lineups containing innocent suspects are less likely to be challenged in court than lineups containing guilty suspects. Correlations within lineup size measures and within some lineup bias measures indicated convergent validity and the correlations across the lineup size and lineup bias measures demonstrated discriminant validity. The reliability of lineup fairness measures across different descriptions was low and reliability across different sets of mock witnesses was moderate to high, depending on the measure. Researchers reporting lineup fairness measures should specify the type of description presented, the amount of detail in the description, and whether the mock witnesses viewed target-present and/or -absent lineups. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
The Black Hull Fleet: Multi-Function Assets for Multi-Mission Duty
2011-01-01
also conduct annual training and mock ex- ercises using pre-staged vessel of opportunity skimming system gear, and all crews receive hazardous waste...Valdez oil spill in 1989, the Oil Pollution Act of 1990 mandated that they be outfittedwith an onboard spilled oil recovery system (SORS) comprised of... outriggers , booms, hydraulic skim- ming equipment, and product storage vessels. The“Black Hull” Fleet Multi-function assets for multi-mission duty. by
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284901 (15 Dec. 2009) --- NASA astronauts Gregory H. Johnson (left), STS-134 pilot; and Michael Fincke, mission specialist, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
Using Mock Trials to Teach Students Forensic Core Competencies in Marriage and Family Therapy
ERIC Educational Resources Information Center
Miller, John K.; Linville, Deanna; Todahl, Jeff; Metcalfe, Joe
2009-01-01
This article provides a description of a university-based project that used mock trials to train both practicum-level marriage and family therapy and law students in forensic work, and a qualitative investigation of student experiences with the training. The content of the training focused on American Association for Marriage and Family Therapy…
Speaking with (Dis)respect: A Study of Reactions to Mock Spanish
ERIC Educational Resources Information Center
Callahan, Laura
2010-01-01
This paper reports on an investigation into the reactions of 147 participants of various ethnicities to a language practice in the USA that has been characterized as Mock Spanish, a special register in which Spanish words or phrases are used to evoke humor by indexing an often unflattering image of Spanish speakers. Research questions include…
ERIC Educational Resources Information Center
Farmer, Kevin; Meisel, Steven I.; Seltzer, Joe; Kane, Kathleen
2013-01-01
The Mock Trial is an experiential exercise adapted from a law school process that encourages students to think critically about theories, topics, and the practice of management in an innovative classroom experience. Playing the role of attorneys and witnesses, learners ask questions and challenge assumptions by playing roles in a trial with…
Order of Verdict Consideration and Decision Rule Effects on Mock Jury Decision Making.
ERIC Educational Resources Information Center
Olaye, Imafidon M.
A study investigated the effects of order verdict consideration and decision rule on jury verdicts. After reading the summary of an actual trial, 240 mock jurors drawn from undergraduate communications classes were randomly assigned to six-member juries. Jury assignments were made under two verdict orders (ascending and descending order of…
Data-Based Active Learning in the Principles of Macroeconomics Course: A Mock FOMC Meeting
ERIC Educational Resources Information Center
Whiting, Cathleen
2006-01-01
The author presents an active-learning exercise for the introductory macroeconomics class in which students participate in a mock Federal Open Market Committee (FOMC) meeting. Preparation involves data gathering and writing both a research report and a policy recommendation. An FOMC meeting is simulated in which students give their policy…
STS-131 crew during SSMTF Ingress/Egress Timeline training
2010-02-10
JSC2010-E-024620 (10 Feb. 2010) --- NASA astronaut Stephanie Wilson, STS-131 mission specialist, participates in an ingress/egress timeline training session in a shuttle mock-up in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. United Space Alliance (USA) instructors David L. Williams (left) and Gary W. Kilgo assisted Wilson.
Dark Energy Survey Year 1 Results: galaxy mock catalogues for BAO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avila, S.; et al.
Mock catalogues are a crucial tool in the analysis of galaxy surveys data, both for the accurate computation of covariance matrices, and for the optimisation of analysis methodology and validation of data sets. In this paper, we present a set of 1800 galaxy mock catalogues designed to match the Dark Energy Survey Year-1 BAO sample (Crocce et al. 2017) in abundance, observational volume, redshift distribution and uncertainty, and redshift dependent clustering. The simulated samples were built upon HALOGEN (Avila et al. 2015) halo catalogues, based on a $2LPT$ density field with an exponential bias. For each of them, a lightconemore » is constructed by the superposition of snapshots in the redshift range $0.45« less
Plasma cleaning of ITER edge Thomson scattering mock-up mirror in the EAST tokamak
NASA Astrophysics Data System (ADS)
Yan, Rong; Moser, Lucas; Wang, Baoguo; Peng, Jiao; Vorpahl, Christian; Leipold, Frank; Reichle, Roger; Ding, Rui; Chen, Junling; Mu, Lei; Steiner, Roland; Meyer, Ernst; Zhao, Mingzhong; Wu, Jinhua; Marot, Laurent
2018-02-01
First mirrors are the key element of all optical and laser diagnostics in ITER. Facing the plasma directly, the surface of the first mirrors could be sputtered by energetic particles or deposited with contaminants eroded from the first wall (tungsten and beryllium), which would result in the degradation of the reflectivity. The impurity deposits emphasize the necessity of the first mirror in situ cleaning for ITER. The mock-up first mirror system for ITER edge Thomson scattering diagnostics has been cleaned in EAST for the first time in a tokamak using radio frequency capacitively coupled plasma. The cleaning properties, namely the removal of contaminants and homogeneity of cleaning were investigated with molybdenum mirror insets (25 mm diameter) located at five positions over the mock-up plate (center to edge) on which 10 nm of aluminum oxide, used as beryllium proxy, were deposited. The cleaning efficiency was evaluated using energy dispersive x-ray spectroscopy, reflectivity measurements and x-ray photoelectron spectroscopy. Using argon or neon plasma without magnetic field in the laboratory and with a 1.7 T magnetic field in the EAST tokamak, the aluminum oxide films were homogeneously removed. The full recovery of the mirrors’ reflectivity was attained after cleaning in EAST with the magnetic field, and the cleaning efficiency was about 40 times higher than that without the magnetic field. All these results are promising for the plasma cleaning baseline scenario of ITER.
Registration of liver images to minimally invasive intraoperative surface and subsurface data
NASA Astrophysics Data System (ADS)
Wu, Yifei; Rucker, D. C.; Conley, Rebekah H.; Pheiffer, Thomas S.; Simpson, Amber L.; Geevarghese, Sunil K.; Miga, Michael I.
2014-03-01
Laparoscopic liver resection is increasingly being performed with results comparable to open cases while incurring less trauma and reducing recovery time. The tradeoff is increased difficulty due to limited visibility and restricted freedom of movement. Image-guided surgical navigation systems have the potential to help localize anatomical features to improve procedural safety and achieve better surgical resection outcome. Previous research has demonstrated that intraoperative surface data can be used to drive a finite element tissue mechanics organ model such that high resolution preoperative scans are registered and visualized in the context of the current surgical pose. In this paper we present an investigation of using sparse data as imposed by laparoscopic limitations to drive a registration model. Non-contact laparoscopicallyacquired surface swabbing and mock-ultrasound subsurface data were used within the context of a nonrigid registration methodology to align mock deformed intraoperative surface data to the corresponding preoperative liver model as derived from pre-operative image segmentations. The mock testing setup to validate the potential of this approach used a tissue-mimicking liver phantom with a realistic abdomen-port patient configuration. Experimental results demonstrates a range of target registration errors (TRE) on the order of 5mm were achieving using only surface swab data, while use of only subsurface data yielded errors on the order of 6mm. Registrations using a combination of both datasets achieved TRE on the order of 2.5mm and represent a sizeable improvement over either dataset alone.
NASA Astrophysics Data System (ADS)
Yang, Xiaochen; Clements, Logan W.; Luo, Ma; Narasimhan, Saramati; Thompson, Reid C.; Dawant, Benoit M.; Miga, Michael I.
2017-03-01
Intra-operative soft tissue deformation, referred to as brain shift, compromises the application of current imageguided surgery (IGS) navigation systems in neurosurgery. A computational model driven by sparse data has been used as a cost effective method to compensate for cortical surface and volumetric displacements. Stereoscopic microscopes and laser range scanners (LRS) are the two most investigated sparse intra-operative imaging modalities for driving these systems. However, integrating these devices in the clinical workflow to facilitate development and evaluation requires developing systems that easily permit data acquisition and processing. In this work we present a mock environment developed to acquire stereo images from a tracked operating microscope and to reconstruct 3D point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space in order to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. Our experimental results report approximately 2mm average displacement error compared with the optical tracking system. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to LRS to collect sufficient intraoperative information for brain shift correction.
Library Circulation Systems: An Overview
ERIC Educational Resources Information Center
Surace, Cecily J.
1972-01-01
The model circulation system outlined is an on-line real time system in which the circulation file is created from the shelf list. The model extends beyond the operational limits of most existing circulation systems and can be considered a reflection of the current state of the art. (36 references) (Author/NH)
Electrical Lumped Model Examination for Load Variation of Circulation System
NASA Astrophysics Data System (ADS)
Koya, Yoshiharu; Ito, Mitsuyo; Mizoshiri, Isao
Modeling and analysis of the circulation system enables the characteristic decision of circulation system in the body to be made. So, many models of circulation system have been proposed. But, they are complicated because the models include a lot of elements. Therefore, we proposed a complete circulation model as a lumped electrical circuit, which is comparatively simple. In this paper, we examine the effectiveness of the complete circulation model as a lumped electrical circuit. We use normal, angina pectoris, dilated cardiomyopathy and myocardial infarction for evaluation of the ventricular contraction function.
Dark Energy Survey Year 1 Results: galaxy mock catalogues for BAO
NASA Astrophysics Data System (ADS)
Avila, S.; Crocce, M.; Ross, A. J.; García-Bellido, J.; Percival, W. J.; Banik, N.; Camacho, H.; Kokron, N.; Chan, K. C.; Andrade-Oliveira, F.; Gomes, R.; Gomes, D.; Lima, M.; Rosenfeld, R.; Salvador, A. I.; Friedrich, O.; Abdalla, F. B.; Annis, J.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Carrasco Kind, M.; Carretero, J.; Castander, F. J.; Cunha, C. E.; da Costa, L. N.; Davis, C.; De Vicente, J.; Doel, P.; Fosalba, P.; Frieman, J.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Hartley, W. G.; Hollowood, D.; Honscheid, K.; James, D. J.; Kuehn, K.; Kuropatkin, N.; Miquel, R.; Plazas, A. A.; Sanchez, E.; Scarpine, V.; Schindler, R.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Walker, A. R.; Dark Energy Survey Collaboration
2018-05-01
Mock catalogues are a crucial tool in the analysis of galaxy surveys data, both for the accurate computation of covariance matrices, and for the optimisation of analysis methodology and validation of data sets. In this paper, we present a set of 1800 galaxy mock catalogues designed to match the Dark Energy Survey Year-1 BAO sample (Crocce et al. 2017) in abundance, observational volume, redshift distribution and uncertainty, and redshift dependent clustering. The simulated samples were built upon HALOGEN (Avila et al. 2015) halo catalogues, based on a 2LPT density field with an empirical halo bias. For each of them, a lightcone is constructed by the superposition of snapshots in the redshift range 0.45 < z < 1.4. Uncertainties introduced by so-called photometric redshifts estimators were modelled with a double-skewed-Gaussian curve fitted to the data. We populate halos with galaxies by introducing a hybrid Halo Occupation Distribution - Halo Abundance Matching model with two free parameters. These are adjusted to achieve a galaxy bias evolution b(zph) that matches the data at the 1-σ level in the range 0.6 < zph < 1.0. We further analyse the galaxy mock catalogues and compare their clustering to the data using the angular correlation function w(θ), the comoving transverse separation clustering ξμ < 0.8(s⊥) and the angular power spectrum Cℓ, finding them in agreement. This is the first large set of three-dimensional {ra,dec,z} galaxy mock catalogues able to simultaneously accurately reproduce the photometric redshift uncertainties and the galaxy clustering.
Soft tissue waxup and mock-up as key factors in a treatment plan: case presentation.
Viana, Pedro Couto; Correia, André; Neves, Manuel; Kovacs, Zsolt; Neugbauer, Rudiger
2012-01-01
Rehabilitation of edentulous spaces in esthetic areas is a challenge to the clinician due to the loss of soft tissues. In these clinical situations, it would be desirable to evaluate and predict the gingival architecture to recover in the oral rehabilitation. To fulfill this need, the diagnostic wax should anticipate the final rehabilitation with the integration of hard and soft tissue. Thus, it is essential to produce a diagnostic waxup that integrates these two components that are simultaneously seeking to recreate the harmony of white and pink esthetic. This diagnostic waxup will be the basis for the creation of the provisional prosthesis and a soft tissue mock-up. After placing the provisional prosthesis in the mouth, the soft tissue mock-up can be applied to assess its esthetic impact at facial and intraoral level. Dentist and patient should objectively assess the appearance of the final result. After approval of this rehabilitation concept, the virtual surgical planning can be performed and the surgical guide can be designed, allowing the treatment to take place. This protocol allows the development of a rigorous treatment plan based on the integration of teeth and gingiva component. The waxup and the soft tissue mock-up play a significant role, since they allow an earlier evaluation of the esthetic result, better prosthetic and surgical planning, and it allows us to anticipate the need for gingiva-colored ceramics use. The authors present a clinical case report of the importance of the wax-up and soft tissue mock-up in the treatment plan.
Taylor, Marcus K; Larson, Gerald E; Hiller Lauby, Melissa D; Padilla, Genieleah A; Wilson, Ingrid E; Schmied, Emily A; Highfill-McRoy, Robyn M; Morgan, Charles A
2014-01-01
Evidence points to heightened physiological arousal in response to acute stress exposure as both a prospective indicator and a core characteristic of posttraumatic stress disorder (PTSD). Because females may be at higher risk for PTSD development, it is important to evaluate sex differences in acute stress reactions. This study characterized sex differences in cardiovascular and subjective stress reactions among military survival trainees. One hundred and eighty-five military members (78% males) were studied before, during, and 24 h after stressful mock captivity. Cardiovascular (heart rate [HR], systolic blood pressure [SBP], diastolic blood pressure [DBP]) and dissociative states were measured at all three time points. Psychological impact of mock captivity was assessed during recovery. General linear modeling with repeated measures evaluated sex differences for each cardiovascular endpoint, and causal steps modeling was used to explore interrelationships among sex, cardiovascular reactions and psychological impact of mock captivity. Although females had lower SBP than males at all three time points, the difference was most pronounced at baseline and during stress. Accordingly, females showed greater residual elevation in SBP during recovery. Females had lower DBP at all three time points. In addition, females reported greater psychological impact of mock captivity than males. Exploratory causal steps modeling suggested that stress-induced HR may partially mediate the effect of sex on psychological impact of mock captivity. In conclusion, this study demonstrated sex-specific cardiovascular stress reactions in military personnel, along with greater psychological impact of stress exposure in females. This research may elucidate sex differences in PTSD development.
Statement of Facts for 1977 City-Wide Mock Trial Competitions. Walker Thomas v. Sam Nomad.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its annual city-wide mock trial competition, this instructional handout provides material for a civil case over an automobile accident. Walker Thomas is suing Sam Nomad for damages that resulted from a collision, for which both parties blame the other. The handout clarifies the laws and…
Statement of Facts for 1976 City-Wide Mock Trial Competitions. United States v. Percy W. Snodgrass.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its annual city-wide mock trial competition, this instructional handout provides material for a murder trial. The defendant shot the victim in the course of a violent dispute. The prosecution charges murder while the defendant claims to have acted in self-defense. The handout clarifies…
Competence Is in the Eye of the Beholder: Perceptions of Intellectually Disabled Child Witnesses
ERIC Educational Resources Information Center
Brown, Deirdre A.; Lewis, Charlie N.
2013-01-01
This study examines mock jurors' perceptions of a young witness according to whether or not he was described as having an intellectual disability. Our study examined perceptions of a child witness younger (five or seven years) than previously studied. Mock jurors ("n" = 71) viewed a short video excerpt of a boy recalling a…
The Effect of Mock Tests on Iranian EFL Learners' Test Scores
ERIC Educational Resources Information Center
Khodabakhshzadeh, Hossein; Zardkanloo, Reza; Alipoor, Iman
2017-01-01
The effect of using tests in test preparation courses has been subject to debate. While some scholars such as Yang and Badger (2015) believe it is a cause of positive washback effect, others argue that this issue is tentative and context-bound (Green, 2007). Therefore, this study investigated the effect of using Mock tests in International English…
Bling My Research! A Mock Grant Panel Activity Illustrating the Importance of Basic Research
ERIC Educational Resources Information Center
Leander, Celeste A.; Whitton, Jeannette
2010-01-01
First-year university students have misconceptions about the source and dynamics of publicly funded research money. We designed an activity in which students take part in a mock grant panel. The results indicated a strong tendency toward student funding of applied medical research at the expense of basic research. Exposure to a few examples of…
NASA Astrophysics Data System (ADS)
Gauthier, P.-A.; Camier, C.; Lebel, F.-A.; Pasco, Y.; Berry, A.; Langlois, J.; Verron, C.; Guastavino, C.
2016-08-01
Sound environment reproduction of various flight conditions in aircraft mock-ups is a valuable tool for the study, prediction, demonstration and jury testing of interior aircraft sound quality and annoyance. To provide a faithful reproduced sound environment, time, frequency and spatial characteristics should be preserved. Physical sound field reproduction methods for spatial sound reproduction are mandatory to immerse the listener's body in the proper sound fields so that localization cues are recreated at the listener's ears. Vehicle mock-ups pose specific problems for sound field reproduction. Confined spaces, needs for invisible sound sources and very specific acoustical environment make the use of open-loop sound field reproduction technologies such as wave field synthesis (based on free-field models of monopole sources) not ideal. In this paper, experiments in an aircraft mock-up with multichannel least-square methods and equalization are reported. The novelty is the actual implementation of sound field reproduction with 3180 transfer paths and trim panel reproduction sources in laboratory conditions with a synthetic target sound field. The paper presents objective evaluations of reproduced sound fields using various metrics as well as sound field extrapolation and sound field characterization.
Is it inherently prejudicial to try a juvenile as an adult?
Levine, M; Williams, A; Sixt, A; Valenti, R
2001-01-01
Given only information that a youth who could have been tried as either an adult or as a juvenile was being tried as an adult for murder, 218 undergraduate mock jurors were able to form consistent impressions of the defendant. A very high percent of our mock jurors included a criminal or juvenile justice history as part of that impression. A very large majority of the mock jurors also said that knowledge of that criminal history would be relevant to their vote of guilty. Almost all mock jurors said they would be influenced toward voting guilty by knowledge of a previous criminal history. Few of the other components of the impression were so closely correlated with a judgment of relevance, or with a judgment that they would be influenced toward voting guilty by the knowledge of that component of the stereotype. The effect is relatively specific to knowledge of a previous criminal history. The study has limited ecological validity. Nonetheless, we raise questions about whether the fact that a youth is put on trial as an adult is inherently prejudicial, and violates the Sixth Amendment right to an impartial jury. Copyright 2001 John Wiley & Sons, Ltd.
Buckley, Elaine Jayne; Markwell, Stephen; Farr, Debb; Sanfey, Hilary; Mellinger, John
2015-10-01
American Board of Surgery In-Service Training Examination (ABSITE) scores are used to assess individual progress and predict board pass rates. We reviewed strategies to enhance ABSITE performance and their impact within a surgery residency. Several interventions were introduced from 2010 to 2014. A retrospective review was undertaken evaluating these and correlating them to ABSITE performance. Analyses of variance and linear trends were performed for ABSITE, United States Medical Licensing Examination (USMLEs), mock oral, and mock ABSITE scores followed by post hoc analyses if significant. Results were correlated with core curricular changes. ABSITE mean percentile increased 34% in 4 years with significant performance improvement and increasing linear trends in postgraduate year (PGY)1 and PGY4 ABSITE scores. Mock ABSITE introduction correlated to significant improvement in ABSITE scores for PGY4 and PGY5. Mock oral introduction correlated with significant improvement in PGY1 and PGY3. Our study demonstrates an improvement in mean program ABSITE percentiles correlating with multiple interventions. Similar strategies may be useful for other programs. Copyright © 2015 Elsevier Inc. All rights reserved.
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284896 (15 Dec. 2009) --- NASA astronauts Gregory H. Johnson (left), STS-134 pilot; along with astronauts Michael Fincke (center) and Greg Chamitoff, both mission specialists, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284893 (15 Dec. 2009) --- NASA astronaut Gregory H. Johnson (right), STS-134 pilot; and European Space Agency astronaut Roberto Vittori, mission specialist, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
When Justice Is Up to You. Celebrating America's Guarantee of Trial by Jury.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Featuring a mock trial tested in the District of Columbia, the objective of this manual is to help students learn more about the constitutional guarantee of trial by jury. Prepared as five separate lessons, the manual examines one alternative to the jury system--trial by ordeal; traces the development of the guarantee of trial by jury; explores…
2018-01-30
Crane operators and ground support personnel practice lifting and stacking mock-ups of solid rocket booster (SRB) segments in High Bay 4 inside the Vehicle Assembly Building at NASA’s Kennedy Space Center in Florida. The training will help workers prepare for SRB stacking operations for the agency's Space Launch System SLS) rocket. The SLS will launch the Orion spacecraft on its first integrated flight, Exploration Mission-1.
Expedition 3 Crew Training Clips
NASA Technical Reports Server (NTRS)
2001-01-01
The Expedition 3 crewmembers, Frank Culbertson, Jr., Mikhail Turin, and Vladimir Dezhurov, are seen during various stages of their training. Footage includes Extravehicular Activity (EVA) Training at the Neutral Buoyancy Laboratory (NBL), EVA Preparation and Post Training in the International Space Station Airlock Mock-up, in the NBL Space Station Remote Manipulator System Workstation, and during the T-38 flight at Ellington Field.
Astronauts Sally Ride and Terry Hart prepare for RMS training for STS-2
1981-07-17
Astronauts Sally Ride and Terry Hart prepare for remote manipulator system (RMS) training for STS-2 in bldg 9A. Views include Ride, Hart and Robert R. Kain of the Flight Activites Branch reviewing procedures for RMS training (34262); Ride and Hart stand beside the RMS control center looking down at the payload bay mock-up (34263).
Yuruk, Koray; Bezemer, Rick; Euser, Mariska; Milstein, Dan M J; de Geus, Hilde H R; Scholten, Evert W; de Mol, Bas A J M; Ince, Can
2012-09-01
OBJECTIVES To reduce the complications associated with cardiopulmonary bypass (CPB) during cardiac surgery, many modifications have been made to conventional extracorporeal circulation systems. This trend has led to the development of miniaturized extracorporeal circulation systems. Cardiac surgery using conventional extracorporeal circulation systems has been associated with significantly reduced microcirculatory perfusion, but it remains unknown whether this could be prevented by an mECC system. Here, we aimed to test the hypothesis that microcirculatory perfusion decreases with the use of a conventional extracorporeal circulation system and would be preserved with the use of an miniaturized extracorporeal circulation system. METHODS Microcirculatory density and perfusion were assessed using sublingual side stream dark-field imaging in patients undergoing on-pump coronary artery bypass graft (CABG) surgery before, during and after the use of either a conventional extracorporeal circulation system (n = 10) or a miniaturized extracorporeal circulation system (n = 10). In addition, plasma neutrophil gelatinase-associated lipocalin and creatinine levels and creatinine clearance were assessed up to 5 days post-surgery to monitor renal function. RESULTS At the end of the CPB, one patient in the miniaturized extracorporeal circulation-treated group and five patients in the conventional extracorporeal circulation-treated group received one bag of packed red blood cells (300 ml). During the CPB, the haematocrit and haemoglobin levels were slightly higher in the miniaturized extracorporeal circulation-treated patients compared with the conventional extracorporeal circulation-treated patients (27.7 ± 3.3 vs 24.7 ± 2.0%; P = 0.03; and 6.42 ± 0.75 vs 5.41 ± 0.64 mmol/l; P < 0.01). The density of perfused vessels with a diameter <25 µm (i.e. perfused vessel density) decreased slightly in the conventional extracorporeal circulation-treated group from 16.4 ± 3.8 to 12.8 ± 3.3 mm/mm(2) (P < 0.01) and remained stable in the miniaturized extracorporeal circulation-treated group (16.3 ± 2.7 and 15.2 ± 2.9 mm/mm(2) before and during the pump, respectively). Plasma neutrophil gelatinase-associated lipocalin levels were increased following the use of extracorporeal circulation in both groups, and no differences were observed between the groups. Plasma creatinine levels and creatinine clearance were not affected by CABG surgery or CPB. CONCLUSIONS The results from this relatively small study suggest that the use of the miniaturized extracorporeal circulation system is associated with a statistically significant (but clinically insignificant) reduction in haemodilution and microcirculatory hypoperfusion compared with the use of the conventional extracorporeal circulation system.
Ng, Boon C; Smith, Peter A; Nestler, Frank; Timms, Daniel; Cohn, William E; Lim, Einly
2017-03-01
The successful clinical applicability of rotary left ventricular assist devices (LVADs) has led to research interest in devising a total artificial heart (TAH) using two rotary blood pumps (RBPs). The major challenge when using two separately controlled LVADs for TAH support is the difficulty in maintaining the balance between pulmonary and systemic blood flows. In this study, a starling-like controller (SLC) hybridized with an adaptive mechanism was developed for a dual rotary LVAD TAH. The incorporation of the adaptive mechanism was intended not only to minimize the risk of pulmonary congestion and atrial suction but also to match cardiac demand. A comparative assessment was performed between the proposed adaptive starling-like controller (A-SLC) and a conventional SLC as well as a constant speed controller. The performance of all controllers was evaluated by subjecting them to three simulated scenarios [rest, exercise, head up tilt (HUT)] using a mock circulation loop. The overall results showed that A-SLC was superior in matching pump flow to cardiac demand without causing hemodynamic instabilities. In contrast, improper flow regulation by the SLC resulted in pulmonary congestion during exercise. From resting supine to HUT, overpumping of the RBPs at fixed speed (FS) caused atrial suction, whereas implementation of SLC resulted in insufficient flow. The comparative study signified the potential of the proposed A-SLC for future TAH implementation particularly among outpatients, who are susceptible to variety of clinical scenarios.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirano, Teruyuki; Suto, Yasushi; Taruya, Atsushi
We obtain analytical expressions for the velocity anomaly due to the Rossiter-McLaughlin (RM) effect, for the case when the anomalous radial velocity is obtained by cross-correlation with a stellar template spectrum. In the limit of vanishing width of the stellar absorption lines, our result reduces to the formula derived by Ohta et al., which is based on the first moment of distorted stellar lines. Our new formula contains a term dependent on the stellar line width, which becomes important when rotational line broadening is appreciable. We generate mock transit spectra for four existing exoplanetary systems (HD 17156, TrES-2, TrES-4, andmore » HD 209458) following the procedure of Winn et al., and find that the new formula is in better agreement with the velocity anomaly extracted from the mock data. Thus, our result provides a more reliable analytical description of the velocity anomaly due to the RM effect, and explains the previously observed dependence of the velocity anomaly on the stellar rotation velocity.« less
Mock jury trials in Taiwan--paving the ground for introducing lay participation.
Huang, Kuo-Chang; Lin, Chang-Ching
2014-08-01
The first mock jury study in Taiwan, in which 279 community members watched a videotaped trial, investigated how jurors' estimates of the relative undesirability of wrongful conviction versus wrongful acquittal predicted individual decisions and how decision rules affected outcomes. The percentage of jurors who viewed wrongful conviction as more undesirable increased from 50.9% to 60.9% after deliberation and jurors' postdeliberation acquittal rate (71.7%) was higher than predeliberation acquittal rate (58.8%). Jurors' estimates of the undesirability of wrongful conviction were not correlated with their predeliberation votes but became positively correlated with their postdeliberation decisions. The unanimous rule facilitated jurors' change of vote, predominantly from conviction to acquittal, than the simple majority rule. Jurors reaching a verdict under the unanimous rule viewed deliberation and the verdict more positively. This study indicates that deliberation can ameliorate the problem of most Taiwanese citizens not viewing wrongful conviction as more undesirable than wrongful acquittal. It also suggests that Taiwan should adopt a unanimous rule for its proposed lay participation system.
21 CFR 866.6020 - Immunomagnetic circulating cancer cell selection and enumeration system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunomagnetic circulating cancer cell selection... Associated Antigen immunological Test Systems § 866.6020 Immunomagnetic circulating cancer cell selection and enumeration system. (a) Identification. An immunomagnetic circulating cancer cell selection and enumeration...
21 CFR 866.6020 - Immunomagnetic circulating cancer cell selection and enumeration system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Immunomagnetic circulating cancer cell selection... Associated Antigen immunological Test Systems § 866.6020 Immunomagnetic circulating cancer cell selection and enumeration system. (a) Identification. An immunomagnetic circulating cancer cell selection and enumeration...
21 CFR 866.6020 - Immunomagnetic circulating cancer cell selection and enumeration system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunomagnetic circulating cancer cell selection... Associated Antigen immunological Test Systems § 866.6020 Immunomagnetic circulating cancer cell selection and enumeration system. (a) Identification. An immunomagnetic circulating cancer cell selection and enumeration...
21 CFR 866.6020 - Immunomagnetic circulating cancer cell selection and enumeration system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Immunomagnetic circulating cancer cell selection... Associated Antigen immunological Test Systems § 866.6020 Immunomagnetic circulating cancer cell selection and enumeration system. (a) Identification. An immunomagnetic circulating cancer cell selection and enumeration...
21 CFR 866.6020 - Immunomagnetic circulating cancer cell selection and enumeration system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Immunomagnetic circulating cancer cell selection... Associated Antigen immunological Test Systems § 866.6020 Immunomagnetic circulating cancer cell selection and enumeration system. (a) Identification. An immunomagnetic circulating cancer cell selection and enumeration...
Development of a Software Safety Process and a Case Study of Its Use
NASA Technical Reports Server (NTRS)
Knight, J. C.
1996-01-01
Research in the year covered by this reporting period has been primarily directed toward: continued development of mock-ups of computer screens for operator of a digital reactor control system; development of a reactor simulation to permit testing of various elements of the control system; formal specification of user interfaces; fault-tree analysis including software; evaluation of formal verification techniques; and continued development of a software documentation system. Technical results relating to this grant and the remainder of the principal investigator's research program are contained in various reports and papers.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-17
... FEDERAL COMMUNICATIONS COMMISSION [AU Docket No. 12-25; DA 12-1446] Mobility Fund Phase I Auction... Mobility Fund Phase I support to be offered in Auction 901, which is to be held on September 27, 2012, and the change of the mock auction date from September 25, 2012 to September 21, 2012. DATES: The mock...
ERIC Educational Resources Information Center
Dotson, Wesley H.
2010-01-01
The purpose of the present study was to identify components of an optional mock exam review session (e.g. requiring students to write answers, providing students grading keys for questions) responsible for improvements in student performance on application-based short-essay exams in an undergraduate behavior modification course. Both…
Seeing is Believing: Video Mock-Ups to Evaluate and Demonstrate Multimedia Designs
ERIC Educational Resources Information Center
Fadde, Peter J.
2007-01-01
A video mock-up is a "design story", described by Patrick Parrish in a recent "TechTrends" article as "imagining the journey of a learner's experience in engaging with a finished design". A design story allows designers to show their design vision to others and to observe features and benefits of the program as a learner would experience it. The…
STS-131 crew training during FFT CCTV Lighting 91019 ( Lights Out).
2009-11-16
JSC2009-E-240951 (16 Nov. 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Naoko Yamazaki (foreground) and NASA astronaut Stephanie Wilson, both STS-131 mission specialists, participate in a Full Fuselage Trainer (FFT) mock-up training session in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. United Space Alliance (USA) instructor David L. Williams assisted the crew members.
Morello, Christopher S; Levinson, Michael S; Kraynyak, Kimberly A; Spector, Deborah H
2011-04-01
To date, no vaccine that is safe and effective against herpes simplex virus 2 (HSV-2) disease has been licensed. In this study, we evaluated a DNA prime-formalin-inactivated-HSV-2 (FI-HSV2) boost vaccine approach in the guinea pig model of acute and recurrent HSV-2 genital disease. Five groups of guinea pigs were immunized and intravaginally challenged with HSV-2. Two groups were primed with plasmid DNAs encoding the secreted form of glycoprotein D2 (gD2t) together with two genes required for viral replication, either the helicase (UL5) and DNA polymerase (UL30) genes or the single-stranded DNA binding protein (UL29) and primase (UL52) genes. Both DNA-primed groups were boosted with FI-HSV2 formulated with monophosphoryl lipid A (MPL) and alum adjuvants. Two additional groups were primed with the empty backbone plasmid DNA (pVAX). These two groups were boosted with MPL and alum (MPL-alum) together with either formalin-inactivated mock HSV-2 (FI-Mock) or with FI-HSV2. The final group was immunized with gD2t protein in MPL-alum. After challenge, 0/9 animals in the group primed with UL5, UL30, and gD2t DNAs and all 10 animals in the mock-immunized control group (pVAX-FI-Mock) developed primary lesions. All mock controls developed recurrent lesions through day 100 postchallenge. Only 1 guinea pig in the group primed with pVAX DNA and boosted with FI-HSV2 (pVAX-FI-HSV2 group) and 2 guinea pigs in the group primed with UL5, UL30, and gD2t DNAs and boosted with FI-HSV2 (UL5, UL30, gD2t DNA-FI-HSV2 group) developed recurrent lesions. Strikingly, the UL5, UL30, gD2t DNA-FI-HSV2 group showed a 97% reduction in recurrent lesion days compared with the mock controls, had the highest reduction in days with recurrent disease, and contained the lowest mean HSV-2 DNA load in the dorsal root ganglia.
THE DEEP2 GALAXY REDSHIFT SURVEY: THE VORONOI-DELAUNAY METHOD CATALOG OF GALAXY GROUPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerke, Brian F.; Newman, Jeffrey A.; Davis, Marc
2012-05-20
We present a public catalog of galaxy groups constructed from the spectroscopic sample of galaxies in the fourth data release from the Deep Extragalactic Evolutionary Probe 2 (DEEP2) Galaxy Redshift Survey, including the Extended Groth Strip (EGS). The catalog contains 1165 groups with two or more members in the EGS over the redshift range 0 < z < 1.5 and 1295 groups at z > 0.6 in the rest of DEEP2. Twenty-five percent of EGS galaxies and fourteen percent of high-z DEEP2 galaxies are assigned to galaxy groups. The groups were detected using the Voronoi-Delaunay method (VDM) after it hasmore » been optimized on mock DEEP2 catalogs following similar methods to those employed in Gerke et al. In the optimization effort, we have taken particular care to ensure that the mock catalogs resemble the data as closely as possible, and we have fine-tuned our methods separately on mocks constructed for the EGS and the rest of DEEP2. We have also probed the effect of the assumed cosmology on our inferred group-finding efficiency by performing our optimization on three different mock catalogs with different background cosmologies, finding large differences in the group-finding success we can achieve for these different mocks. Using the mock catalog whose background cosmology is most consistent with current data, we estimate that the DEEP2 group catalog is 72% complete and 61% pure (74% and 67% for the EGS) and that the group finder correctly classifies 70% of galaxies that truly belong to groups, with an additional 46% of interloper galaxies contaminating the catalog (66% and 43% for the EGS). We also confirm that the VDM catalog reconstructs the abundance of galaxy groups with velocity dispersions above {approx}300 km s{sup -1} to an accuracy better than the sample variance, and this successful reconstruction is not strongly dependent on cosmology. This makes the DEEP2 group catalog a promising probe of the growth of cosmic structure that can potentially be used for cosmological tests.« less
NASA Astrophysics Data System (ADS)
Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard
2012-11-01
For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq
Kosaka, Ryo; Maruyama, Osamu; Nishida, Masahiro; Yada, Toru; Saito, Sakae; Hirai, Shusaku; Yamane, Takashi
2009-10-01
We have developed a noncontact-type centrifugal blood pump with hydrodynamic bearings and a semi-open impeller for mechanical circulatory assist. The impeller is levitated by an original spiral-groove thrust bearing and a herringbone-groove journal bearing, without any additional displacement-sensing module or additional complex control circuits. The pump was improved by optimizing the groove direction of the spiral-groove thrust bearing and the pull-up magnetic force between the rotor magnet and the stator coil against the impeller. To evaluate hemocompatibility, we conducted a levitation performance test and in vitro hemocompatibility tests by means of a mock-up circulation loop. In the hemolysis test, the normalized index of hemolysis was reduced from 0.721 to 0.0335 g/100 L corresponding to an expansion of the bearing gap from 1.1 to 56.1 microm. In the in vitro antithrombogenic test, blood pumps with a wide thrust bearing gap were effective in preventing thrombus formation. Through in vitro evaluation tests, we confirmed that hemocompatibility was improved by balancing the hydrodynamic fluid dynamics and magnetic forces.
SpaceX Dragon Air Circulation System
NASA Technical Reports Server (NTRS)
Hernandez, Brenda; Piatrovich, Siarhei; Prina, Mauro
2011-01-01
The Dragon capsule is a reusable vehicle being developed by Space Exploration Technologies (SpaceX) that will provide commercial cargo transportation to the International Space Station (ISS). Dragon is designed to be a habitable module while it is berthed to ISS. As such, the Dragon Environmental Control System (ECS) consists of pressure control and pressure equalization, air sampling, fire detection, illumination, and an air circulation system. The air circulation system prevents pockets of stagnant air in Dragon that can be hazardous to the ISS crew. In addition, through the inter-module duct, the air circulation system provides fresh air from ISS into Dragon. To utilize the maximum volume of Dragon for cargo packaging, the Dragon ECS air circulation system is designed around cargo rack optimization. At the same time, the air circulation system is designed to meet the National Aeronautics Space Administration (NASA) inter-module and intra-module ventilation requirements and acoustic requirements. A flight like configuration of the Dragon capsule including the air circulation system was recently assembled for testing to assess the design for inter-module and intra-module ventilation and acoustics. The testing included the Dragon capsule, and flight configuration in the pressure section with cargo racks, lockers, all of the air circulation components, and acoustic treatment. The air circulation test was also used to verify the Computational Fluid Dynamics (CFD) model of the Dragon capsule. The CFD model included the same Dragon internal geometry that was assembled for the test. This paper will describe the Dragon air circulation system design which has been verified by testing the system and with CFD analysis.
NASA Technical Reports Server (NTRS)
Shields, N. L., Jr.; Martin, M. F.; Paulukaitis, K. R.; Haslam, J. W., Jr.; Henderson, D. E.
1986-01-01
The teleoperator and Robotics Evaluation Facility (TOREF) is composed of a 4,000 square foot precision air bearing floor, the Teleoperator Motion Base, the Target Motion and Support Simulator, the mock-ups of the Hubble Space Telescope, Multi-mission Modular Spacecraft, and the Orbital Maneuvering Vehicle (OMV). The TOREF and its general capabilities to support the OMV and other remote system simulations; the facility operating procedures and requirements; and the results of generic OMV investigations are summarized.
Gregory, Shaun D; Schummy, Emma; Pearcy, Mark; Pauls, Jo P; Tansley, Geoff; Fraser, John F; Timms, Daniel
2015-02-01
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A Detection of the Baryon Acoustic Oscillation Features in the SDSS BOSS DR12 Galaxy Bispectrum
NASA Astrophysics Data System (ADS)
Pearson, David W.; Samushia, Lado
2018-05-01
We present the first high significance detection (4.1σ) of the Baryon Acoustic Oscillations (BAO) feature in the galaxy bispectrum of the twelfth data release (DR12) of the Baryon Oscillation Spectroscopic Survey (BOSS) CMASS sample (0.43 ≤ z ≤ 0.7). We measured the scale dilation parameter, α, using the power spectrum, bispectrum, and both simultaneously for DR12, plus 2048 MultiDark-PATCHY mocks in the North and South Galactic Caps (NGC and SGC, respectively), and the volume weighted averages of those two samples (N+SGC). The fitting to the mocks validated our analysis pipeline, yielding values consistent with the mock cosmology. By fitting to the power spectrum and bispectrum separately, we tested the robustness of our results, finding consistent values from the NGC, SGC and N+SGC in all cases. We found DV = 2032 ± 24(stat.) ± 15(sys.) Mpc, DV = 2038 ± 55(stat.) ± 15(sys.) Mpc, and DV = 2031 ± 22(stat.) ± 10(sys.) Mpc from the N+SGC power spectrum, bispectrum and simultaneous fitting, respectively. Our bispectrum measurement precision was mainly limited by the size of the covariance matrix. Based on the fits to the mocks, we showed that if a less noisy estimator of the covariance were available, from either a theoretical computation or a larger suite of mocks, the constraints from the bispectrum and simultaneous fits would improve to 1.1 per cent (1.3 per cent with systematics) and 0.7 per cent (0.9 per cent with systematics), respectively, with the latter being slightly more precise than the power spectrum only constraints from the reconstructed field.
Ghiasi, Homayon; Osorio, Yanira; Nesburn, Anthony B; Wechsler, Steven L
2002-10-25
STAT6 (signal transducers and activators of transcription 6)-deficient (STAT6-/-) mice have defects in IL-4- and IL-13-mediated functions and thus have a reduced T(H)2-mediated immune response. Conversely, they have elevated levels of IL-2 and thus an increased T(H)1-mediated immune response. To assess the relative impact of reduced T(H)2- and elevated T(H)1-dependent immune responses on HSV-1 infection, vaccinated and mock-vaccinated STAT6-/- mice were challenged ocularly with HSV-1. Mock-vaccinated STAT6-/- mice were as susceptible to lethal HSV-1 infection as parental BALB/c mice. Mock-vaccinated STAT6-/- mice had reduced HSV-1 titers in their eyes compared to BALB/c mice. Furthermore, mock-vaccinated STAT6-/- mice had significantly less corneal scarring than their BALB/c counterparts. Vaccination induced significantly higher serum-neutralizing antibody titers in STAT6-/- mice compared to BALB/c mice, while completely protecting both types of mice against HSV-1-induced death and corneal scarring. Vaccinated STAT6-/- mice had reduced HSV-1 titers in their eyes compared to BALB/c mice. Lymphocytes from both vaccinated and mock-vaccinated STAT6-/- mice secreted higher amounts of IL-2 than lymphocytes from BALB/c mice, in the presence or absence of stimulation with UV-inactivated HSV-1. Finally, depletion of IL-2 increased ocular virus replication in STAT6-/- mice to levels similar to that measured in BALB/c mice. Our results suggest that in the absence of the STAT6 pathway, IL-2-mediated immune responses are up-regulated. This, in turn, leads to faster viral clearance and, consequently, lower levels of eye disease.
Soneral, Paula A G; Wyse, Sara A
2017-01-01
Student-centered learning environments with upside-down pedagogies (SCALE-UP) are widely implemented at institutions across the country, and learning gains from these classrooms have been well documented. This study investigates the specific design feature(s) of the SCALE-UP classroom most conducive to teaching and learning. Using pilot survey data from instructors and students to prioritize the most salient SCALE-UP classroom features, we created a low-tech "Mock-up" version of this classroom and tested the impact of these features on student learning, attitudes, and satisfaction using a quasi--experimental setup. The same instructor taught two sections of an introductory biology course in the SCALE-UP and Mock-up rooms. Although students in both sections were equivalent in terms of gender, grade point average, incoming ACT, and drop/fail/withdraw rate, the Mock-up classroom enrolled significantly more freshmen. Controlling for class standing, multiple regression modeling revealed no significant differences in exam, in-class, preclass, and Introduction to Molecular and Cellular Biology Concept Inventory scores between the SCALE-UP and Mock-up classrooms. Thematic analysis of student comments highlighted that collaboration and whiteboards enhanced the learning experience, but technology was not important. Student satisfaction and attitudes were comparable. These results suggest that the benefits of a SCALE-UP experience can be achieved at lower cost without technology features. © 2017 P. A. G. Soneral and S. A. Wyse. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).
Circulation Systems on Microcomputers.
ERIC Educational Resources Information Center
Carlson, Gary
1984-01-01
Reports on the use of microcomputers in comprehensive library circulation systems. Topics covered include system requirements (reliability, completeness); determining circulation system needs (saving money, improving service, modernization); limitations of microcomputers (capacity, kinds of data stored, number of stations or terminals); system…
Pollina, Dean A; Dollins, Andrew B; Senter, Stuart M; Krapohl, Donald J; Ryan, Andrew H
2004-12-01
In a preliminary attempt to determine the generalizability of data from laboratory mock-crime studies, the authors examined the similarities and differences among the cardiovascular, electrodermal, and respiration responses of deceptive and nondeceptive individuals elicited to crime-relevant and crime-irrelevant questions. Participants in the laboratory group were randomly assigned to nondeceptive (n = 28) or deceptive (n = 27) treatment groups, and a mock-crime scenario was used. The field participants were confirmed nondeceptive (n = 28) or deceptive (n = 39) criminal suspects who underwent polygraph examinations between 1993 and 1997. The results indicated that there were salient differences between field and similarly obtained laboratory polygraph response measures. However, accuracy of laboratory participants' classifications using logistic regression analysis was not significantly different from field participants' classification accuracy. 2004 APA, all rights reserved
Stealing thunder as a courtroom tactic revisited: processes and boundaries.
Dolnik, Lara; Case, Trevor I; Williams, Kipling D
2003-06-01
Stealing thunder refers to a dissuasion tactic in which an individual reveals potentially incriminating evidence first, for the purpose of reducing its negative impact on an evaluative audience. We examined whether it was necessary to frame the negative revelation in a manner that downplayed its importance, and found that stealing thunder successfully dissuaded mock jurors even without framing. We also sought to determine the mechanism by which stealing thunder operated, and found that stealing thunder led mock jurors to change the meaning of incriminating evidence to be less damaging to the individual. We also found that stealing thunder's effectiveness did not hinge on whether or not opposing counsel also mentioned the thunder evidence, and that the stealing thunder tactic was no longer effective when opposing counsel revealed to the mock jurors that the stealing thunder tactic had been used on them.
Yuruk, Koray; Bezemer, Rick; Euser, Mariska; Milstein, Dan M.J.; de Geus, Hilde H.R.; Scholten, Evert W.; de Mol, Bas A.J.M.; Ince, Can
2012-01-01
OBJECTIVES To reduce the complications associated with cardiopulmonary bypass (CPB) during cardiac surgery, many modifications have been made to conventional extracorporeal circulation systems. This trend has led to the development of miniaturized extracorporeal circulation systems. Cardiac surgery using conventional extracorporeal circulation systems has been associated with significantly reduced microcirculatory perfusion, but it remains unknown whether this could be prevented by an mECC system. Here, we aimed to test the hypothesis that microcirculatory perfusion decreases with the use of a conventional extracorporeal circulation system and would be preserved with the use of an miniaturized extracorporeal circulation system. METHODS Microcirculatory density and perfusion were assessed using sublingual side stream dark-field imaging in patients undergoing on-pump coronary artery bypass graft (CABG) surgery before, during and after the use of either a conventional extracorporeal circulation system (n = 10) or a miniaturized extracorporeal circulation system (n = 10). In addition, plasma neutrophil gelatinase-associated lipocalin and creatinine levels and creatinine clearance were assessed up to 5 days post-surgery to monitor renal function. RESULTS At the end of the CPB, one patient in the miniaturized extracorporeal circulation-treated group and five patients in the conventional extracorporeal circulation-treated group received one bag of packed red blood cells (300 ml). During the CPB, the haematocrit and haemoglobin levels were slightly higher in the miniaturized extracorporeal circulation-treated patients compared with the conventional extracorporeal circulation-treated patients (27.7 ± 3.3 vs 24.7 ± 2.0%; P = 0.03; and 6.42 ± 0.75 vs 5.41 ± 0.64 mmol/l; P < 0.01). The density of perfused vessels with a diameter <25 µm (i.e. perfused vessel density) decreased slightly in the conventional extracorporeal circulation-treated group from 16.4 ± 3.8 to 12.8 ± 3.3 mm/mm2 (P < 0.01) and remained stable in the miniaturized extracorporeal circulation-treated group (16.3 ± 2.7 and 15.2 ± 2.9 mm/mm2 before and during the pump, respectively). Plasma neutrophil gelatinase-associated lipocalin levels were increased following the use of extracorporeal circulation in both groups, and no differences were observed between the groups. Plasma creatinine levels and creatinine clearance were not affected by CABG surgery or CPB. CONCLUSIONS The results from this relatively small study suggest that the use of the miniaturized extracorporeal circulation system is associated with a statistically significant (but clinically insignificant) reduction in haemodilution and microcirculatory hypoperfusion compared with the use of the conventional extracorporeal circulation system. PMID:22700685
STS-135 crew during Ingress/Egress Timeline training in building 9NW space station mockups
2011-04-29
JSC2011-E-043876 (29 April 2011) --- NASA astronauts Sandy Magnus and Rex Walheim (mostly out of frame at right), both STS-135 mission specialists, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Photo credit: NASA
STS-135 crew during Ingress/Egress Timeline training in building 9NW space station mockups
2011-04-29
JSC2011-E-043872 (29 April 2011) --- NASA astronauts Sandy Magnus and Rex Walheim, both STS-135 mission specialists, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. A crew instructor (right) assisted Magnus and Walheim. Photo credit: NASA
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284898 (15 Dec. 2009) --- NASA astronauts Gregory H. Johnson (center), STS-134 pilot; and Michael Fincke (right), mission specialist; along with European Space Agency astronaut Roberto Vittori, mission specialist, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284900 (15 Dec. 2009) --- NASA astronauts Gregory H. Johnson (center), STS-134 pilot; and Michael Fincke (right), mission specialist; along with European Space Agency astronaut Roberto Vittori, mission specialist, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
NASA Technical Reports Server (NTRS)
Muniz, Beau
2009-01-01
One unique project that the Prototype lab worked on was PORT I (Post-landing Orion Recovery Test). PORT is designed to test and develop the system and components needed to recover the Orion capsule once it splashes down in the ocean. PORT II is designated as a follow up to PORT I that will utilize a mock up pressure vessel that is spatially compar able to the final Orion capsule.
The verdict on jury trials for juveniles: the effects of defendant's age on trial outcomes.
Warling, Diane; Peterson-Badali, Michele
2003-01-01
With the progression to more adult-like policies and procedures for youth in the justice system, the right to a jury trial has been extended to young offenders. These youth would not be tried by a jury of their peers, however, but by a jury of adults. The concern is that adult jurors may hold negative attitudes about youth that might influence their decision making in a case involving a young defendant. Two studies examined whether and under what conditions defendant's age affects jurors' decisions about the guilt and sentencing of an accused. In study 1, data were gathered from two samples of jury eligible adults: one university sample and one public sample. Mock jurors read written transcripts of a trial involving a defendant who was presented as either 13, 17, or 25 years of age. Results indicated that the defendant's age had no effect on mock jurors' verdict or their ratings of defendant guilt. However, younger defendants were granted shorter sentences than the adult defendants. In study 2, mock jurors read the same trial presented in study 1 but were asked to deliberate about the case and render group verdicts. These group verdicts did not differ significantly by defendant's age. Age-related themes that emerged from group deliberations were identified, and results indicated that age tended to be used as a mitigating factor in favor of youth rather than against them. These findings are discussed in terms of their implications for youth justice policy and practice. Copyright 2003 John Wiley & Sons, Ltd.
[Computerized ranking test in three French universities: Staff experience and students' feedback].
Roux, D; Meyer, G; Cymbalista, F; Bouaziz, J-D; Falgarone, G; Tesniere, A; Gervais, J; Cariou, A; Peffault de Latour, R; Marat, M; Moenaert, E; Guebli, T; Rodriguez, O; Lefort, A; Dreyfuss, D; Hajage, D; Ricard, J-D
2016-03-01
The year 2016 will be pivotal for the evaluation of French medical students with the introduction of the first computerized National Ranking Test (ECNi). The SIDES, online electronic system for medical student evaluation, was created for this purpose. All the universities have already organized faculty exams but few a joint computerized ranking test at several universities simultaneously. We report our experience on the organization of a mock ECNi by universities Paris Descartes, Paris Diderot and Paris 13. Docimological, administrative and technical working groups were created to organize this ECNi. Students in their fifth year of medical studies, who will be the first students to sit for the official ECNi in 2016, were invited to attend this mock exam that represented more than 50% of what will be proposed in 2016. A final electronic questionnaire allowed a docimological and organizational evaluation by students. An analysis of ratings and rankings and their distribution on a 1000-point scale were performed. Sixty-four percent of enrolled students (i.e., 654) attended the three half-day exams. No difference in total score and ranking between the three universities was observed. Students' feedback was extremely positive. Normalized over 1000 points, 99% of students were scored on 300 points only. Progressive clinical cases were the most discriminating test. The organization of a mock ECNi involving multiple universities was a docimological and technical success but required an important administrative, technical and teaching investment. Copyright © 2016 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Development and Pilot Testing of a Video-Assisted Informed Consent Process
Sonne, Susan C.; Andrews, Jeannette O.; Gentilin, Stephanie M.; Oppenheimer, Stephanie; Obeid, Jihad; Brady, Kathleen; Wolf, Sharon; Davis, Randal; Magruder, Kathryn
2013-01-01
The informed consent process for research has come under scrutiny, as consent documents are increasingly long and difficult to understand. Innovations are needed to improve comprehension in order to make the consent process truly informed. We report on the development and pilot testing of video clips that could be used during the consent process to better explain research procedures to potential participants. Based on input from researchers and community partners, 15 videos of common research procedures/concepts were produced. The utility of the videos was then tested by embedding them in mock informed consent documents that were presented via an online electronic consent system designed for delivery via iPad. Three mock consents were developed, each containing five videos. All participants (n=61) read both a paper version and the video-assisted iPad version of the same mock consent and were randomized to which format they reviewed first. Participants were given a competency quiz that posed specific questions about the information in the consent after reviewing the first consent document to which they were exposed. Most participants (78.7%) preferred the video-assisted format compared to paper (12.9%). Nearly all (96.7%) reported that the videos improved their understanding of the procedures described in the consent document; however, comprehension of material did not significantly differ by consent format. Results suggest videos may be helpful in providing participants with information about study procedures in a way that is easy to understand. Additional testing of video consents for complex protocols and with subjects of lower literacy is warranted. PMID:23747986
Development and pilot testing of a video-assisted informed consent process.
Sonne, Susan C; Andrews, Jeannette O; Gentilin, Stephanie M; Oppenheimer, Stephanie; Obeid, Jihad; Brady, Kathleen; Wolf, Sharon; Davis, Randal; Magruder, Kathryn
2013-09-01
The informed consent process for research has come under scrutiny, as consent documents are increasingly long and difficult to understand. Innovations are needed to improve comprehension in order to make the consent process truly informed. We report on the development and pilot testing of video clips that could be used during the consent process to better explain research procedures to potential participants. Based on input from researchers and community partners, 15 videos of common research procedures/concepts were produced. The utility of the videos was then tested by embedding them in mock-informed consent documents that were presented via an online electronic consent system designed for delivery via iPad. Three mock consents were developed, each containing five videos. All participants (n = 61) read both a paper version and the video-assisted iPad version of the same mock consent and were randomized to which format they reviewed first. Participants were given a competency quiz that posed specific questions about the information in the consent after reviewing the first consent document to which they were exposed. Most participants (78.7%) preferred the video-assisted format compared to paper (12.9%). Nearly all (96.7%) reported that the videos improved their understanding of the procedures described in the consent document; however, the comprehension of material did not significantly differ by consent format. Results suggest videos may be helpful in providing participants with information about study procedures in a way that is easy to understand. Additional testing of video consents for complex protocols and with subjects of lower literacy is warranted. Copyright © 2013 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its annual city-wide mock trial competition, this instructional handout provides material for a civil case over an automobile accident. After drinking heavily at a party hosted by Sandy Hearst, Dana Ivy ran a stop sign and struck the car of Terry Vickers, causing him to sustain a broken…
powerbox: Arbitrarily structured, arbitrary-dimension boxes and log-normal mocks
NASA Astrophysics Data System (ADS)
Murray, Steven G.
2018-05-01
powerbox creates density grids (or boxes) with an arbitrary two-point distribution (i.e. power spectrum). The software works in any number of dimensions, creates Gaussian or Log-Normal fields, and measures power spectra of output fields to ensure consistency. The primary motivation for creating the code was the simple creation of log-normal mock galaxy distributions, but the methodology can be used for other applications.
Mock Code: A Code Blue Scenario Requested by and Developed for Registered Nurses
Rideout, Janice; Pritchett-Kelly, Sherry; McDonald, Melissa; Mullins-Richards, Paula; Dubrowski, Adam
2016-01-01
The use of simulation in medical training is quickly becoming more common, with applications in emergency, surgical, and nursing education. Recently, registered nurses working in surgical inpatient units requested a mock code simulation to practice skills, improve knowledge, and build self-confidence in a safe and controlled environment. A simulation scenario using a high-fidelity mannequin was developed and will be discussed herein. PMID:28123919
ERIC Educational Resources Information Center
Constitutional Rights Foundation, Los Angeles, CA.
Each year the Constitutional Rights Foundation (CRF) seeks to create a mock trial that addresses serious matters facing young people today. In recent times, the actions and behaviors of student groups on high school and college campuses have become major stories in the national media. Incidents of hazing and peer pressure have raised questions…
2011-06-29
JSC2011-E-060135 (29 June 2011) --- The crew of STS-135, from left, Chris Ferguson, Rex Walheim, Doug Hurley and Sandy Magnus, review procedures on the middeck of the Crew Compartment Trainer (CCT) mock-up as they train at NASA?s Johnson Space Center in Houston on June 29, 2011. The training marked the crew's final scheduled session in the Space Vehicle Mock-up Facility. Photo credit: NASA photo/Houston Chronicle, Smiley N. Pool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, H.; Fukui, S.; Iwahashi, Y.
1994-12-31
The development of inspection technique and tool for Bottom Mounted Instrument (BMI) nozzle of PWR plant was performed for countermeasure of leakage accident at incore instrument nozzle of Hamaoka-1 (BWR). MHI achieved the following development, of which object was PWR Plant R/V: (1) development of ECT/UT Multi-sensored Probe; (2) development of Inspection System (3) development of Data Processing System. The Inspection System had been functionally tested using full scale mock-up. As the result of the functional test, this system was confirmed to be very effective, and assumed to be hopeful for the actual application on site.
ERIC Educational Resources Information Center
Guthrie, Gerry D.
The objective of this study was to provide the library community with basic statistical data from on-line activity in the Ohio State University Libraries' Circulation System. Over 1.6 million archive records in the circulation system for 1972 were investigated to produce subject reports of circulation activity, activity reports by collection…
Astronaut Gene Cernan poses in front of Gemini Mission Simulator
1966-08-09
S66-32698 (17 June 1966) --- Astronaut Eugene A. Cernan discusses his Gemini-9A extravehicular activity before a gathering of news media representatives in the MSC auditorium. In the background is an Astronaut Maneuvering Unit (AMU) mock-up mounted in a mock-up of a Gemini spacecraft adapter equipment section. Astronauts Cernan and Thomas P. Stafford completed their three-day mission in space on June 6, 1966. Photo credit: NASA
ASTP crewmen in Soyuz orbital module mock-up during training session at JSC
NASA Technical Reports Server (NTRS)
1975-01-01
An interior view of the Soyuz orbital module mock-up in bldg 35 during Apollo Soyuz Test Project (ASTP) joint crew training at JSC. The ASTP crewmen are Astronaut Vance D. Brand (on left), command module pilot of the American ASTP prime crew; and Cosmonaut Valeriy N. Kubasov, engineer on the Soviet ASTP first (prime) crew. The training session simulated activities on the second day in Earth orbit.
Mock Data Challenge for the MPD/NICA Experiment on the HybriLIT Cluster
NASA Astrophysics Data System (ADS)
Gertsenberger, Konstantin; Rogachevsky, Oleg
2018-02-01
Simulation of data processing before receiving first experimental data is an important issue in high-energy physics experiments. This article presents the current Event Data Model and the Mock Data Challenge for the MPD experiment at the NICA accelerator complex which uses ongoing simulation studies to exercise in a stress-testing the distributed computing infrastructure and experiment software in the full production environment from simulated data through the physical analysis.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its 15th annual city-wide mock trial competition, this instructional handout provides the material for a deportation hearing. The Immigration and Naturalization Service denied political asylum to Toni Radcliffe and seeks authority to deport him. Radcliffe claims that the articles that he…
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its annual city-wide mock trial competition, this instructional handout provides material for the hearing of a custody dispute. Martha Winstead petitions the court to order the Church of the New Family to turn over her 18-year-old son, Jeremiah, to her and to allow her custody. Jeremiah…
Lupu, Ana M; Stewart, Autumn L; O'Neil, Christine
2012-03-12
To compare 3 strategies for pharmacy student learning of motivational interviewing skills, knowledge of motivational interviewing principles, and confidence in and attitudes toward their application. Following a motivational interviewing lecture, first-year students were randomized to perform practice activities (written dialogue, peer role-play, or mock-patient counseling activities). Motivational interviewing skills, knowledge, confidence, and attitudes were measured. All students demonstrated improvement in skills, knowledge, and confidence. Students in the mock-patient counseling group demonstrated significantly better motivational interviewing skills during practice and trended toward higher scores on the summative evaluation. They also demonstrated a significant improvement in knowledge compared with that of the written dialogue group during practice. Feedback at the end was generally positive, with students expressing recognition for the value of motivational interviewing. Students demonstrated their best performance of motivational interviewing during assessments using interactions with mock or standardized patients.
Preparation of W/CuCrZr mono-block test mock-up using vacuum brazing technique
NASA Astrophysics Data System (ADS)
Premjit Singh, K.; Khirwadkar, S.; Bhope, Kedar; Patel, Nikunj; Mokaria, Prakash
2017-04-01
Development of the joining for W/CuCrZr mono-block PFC test mock-up is an interesting area in Fusion R&D. W/Cu bimetallic material has been prepared using OFHC Copper casting approach on the radial surface of W mono-block tile surface. The W/Cu bimetallic material has been joined with CuCrZr tube (heat sink) material with the vacuum brazing route. Vacuum brazing of W/Cu-CuCrZr has been performed @ 970°C for 10 min using NiCuMn-37 filler material under deep vacuum environment (10-6 mbar). Graphite fixture was used for OFHC Copper casting and vacuum brazing experiments. The joint integrity of W/Cu-CuCrZr mono-block mock-up of W/Cu and Cu-CuCrZr interface has been checked using ultrasonic immersion technique. The result of the experimental work is presented in the paper.
Revisiting the NVSS number count dipole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tiwari, Prabhakar; Nusser, Adi, E-mail: ptiwari@physics.technion.ac.il, E-mail: adi@physics.technion.ac.il
We present a realistic modeling of the dipole component of the projected sky distribution of NVSS radio galaxies. The modeling relies on mock catalogs generated within the context of ΛCDM cosmology, in the linear regime of structure formation. After removing the contribution from the solar motion, the mocks show that the remaining observed signal is mostly (70%) due to structures within z ∼< 0.1. The amplitude of the model signal depends on the bias factor b of the NVSS mock galaxies. For sources with flux density, S > 15 mJy, the bias recipe inferred from higher order moments is consistent with the observed dipole signalmore » at 2.12σ. Flux thresholds above 20 mJy yield a disagreement close to the 3σ level. A constant high bias, b = 3 is needed to mitigate the tension to the ∼ 2.3σ level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeager, John D.; Higginbotham Duque, Amanda L.; Shorty, Marvin
Inert surrogates or mocks for high explosives are commonly used in place of the real material for complex experiments or in situations where safety is a concern. We tested several materials as potential mocks for HMX in terms of density, thermal stability, and processability. Selection criteria were developed and a literature search was conducted primarily using the Cambridge Structural Database. Moreover, out of over 200 potentially acceptable materials, six were chosen for crystallization experiments and a suite of analytical characterization. Of these six, 5-iodo-2'-deoxyuridine, N,N'-bis(2,3,4,5,6-pentafluorophenyl)oxamide, and 2,3,4,5,6-pentafluorobenzamide all were found to be thermally stable at 150°C, matched HMX density asmore » a pressed pellet, and could be crystallized to appropriate particle sizes. These three materials are considered suitable inert density mocks for HMX and will be the subject of future testing.« less
In vitro microfluidic circulatory system for circulating cancer cells
wan, jiandi; Fan, Rong; Emery, Travis; Zhang, Yongguo; Xia, Yuxuan; Sun, Jun; Wan, Jiandi
2016-01-01
Circulating tumor cells (CTCs) experience hemodynamic shear stress in circulation and play critical roles in cancer metastasis. The effect of shear on CTCs, however, remains less studied. Here, we described a protocol to circulate HCT116 human colon cancer cells in a microfluidic circulatory system mimicking physiologically relevant circulating conditions. This protocol represents a useful scaffold to mimic the transportation of CTCs in circulation and thus provides an effective means to study the effect of shear on CTCs. We anticipate that future studies using the developed system will help us to further investigate the regulatory roles of shear in molecular responses of CTCs. PMID:28690779
STS-135 crew during Ingress/Egress Timeline training in building 9NW space station mockups
2011-04-29
JSC2011-E-043869 (29 April 2011) --- NASA astronauts Sandy Magnus and Rex Walheim, both STS-135 mission specialists, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. A model of a space shuttle is in the foreground. Photo credit: NASA
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183521 (3 Nov. 2010) --- NASA astronaut Chris Ferguson, STS-135 commander, participates in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284895 (15 Dec. 2009) --- NASA astronauts Gregory H. Johnson (left), STS-134 pilot; along with astronauts Michael Fincke, Greg Chamitoff and Andrew Feustel (mostly out of frame), all mission specialists, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center.
1987-06-05
tareas of land which, they claim, belongs to them in Montecristi. The farm workers traveled from Ruta de Rita locality, and gave notice that they...8217 Children Without Schools 44 MNR Ousting Mocked 45 BRAZIL Poll Shows 70 Percent Favor Shorter Term for Sarney (FOLHA DE SAO PAULO, 15 Mar 87) 46...8217CUT’ President on Talks With Government, Strike Plans (Jair Meneguelli Interview; FOLHA DE SAO PAULO, 6 Apr 87) 50 Parliamentary System
2014-09-16
SAN DIEGO, Calif. – A mock-up of the Orion forward bay cover is lowered by crane from the USS Anchorage into the water during the second day of Orion Underway Recovery Test 3 in the Pacific Ocean. Nearby, U.S. navy divers in two Zodiac boats and other team members in a rigid hull inflatable boat, wait to practice recovery procedures. NASA, Lockheed Martin and U.S. Navy personnel are conducting the recovery test using the Orion boilerplate test vehicle and mock-up forward bay cover to prepare for recovery of the Orion crew module on its return from a deep space mission. The test allows the teams to demonstrate and evaluate the recovery processes, procedures, hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion is scheduled to launch in 2014 atop a United Launch Alliance Delta IV Heavy rocket and in 2018 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Ishii, Tadashi; Nakayama, Masaharu; Abe, Michiaki; Takayama, Shin; Kamei, Takashi; Abe, Yoshiko; Yamadera, Jun; Amito, Koichiro; Morino, Kazuma
2016-10-01
Introduction There were 5,385 deceased and 710 missing in the Ishinomaki medical zone following the Great East Japan Earthquake that occurred in Japan on March 11, 2011. The Ishinomaki Zone Joint Relief Team (IZJRT) was formed to unify the relief teams of all organizations joining in support of the Ishinomaki area. The IZJRT expanded relief activity as they continued to manually collect and analyze assessments of essential information for maintaining health in all 328 shelters using a paper-type survey. However, the IZJRT spent an enormous amount of time and effort entering and analyzing these data because the work was vastly complex. Therefore, an assessment system must be developed that can tabulate shelter assessment data correctly and efficiently. The objective of this report was to describe the development and verification of a system to rapidly assess evacuation centers in preparation for the next major disaster. Report Based on experiences with the complex work during the disaster, software called the "Rapid Assessment System of Evacuation Center Condition featuring Gonryo and Miyagi" (RASECC-GM) was developed to enter, tabulate, and manage the shelter assessment data. Further, a verification test was conducted during a large-scale Self-Defense Force (SDF) training exercise to confirm its feasibility, usability, and accuracy. The RASECC-GM comprises three screens: (1) the "Data Entry screen," allowing for quick entry on tablet devices of 19 assessment items, including shelter administrator, living and sanitary conditions, and a tally of the injured and sick; (2) the "Relief Team/Shelter Management screen," for registering information on relief teams and shelters; and (3) the "Data Tabulation screen," which allows tabulation of the data entered for each shelter, as well as viewing and sorting from a disaster headquarters' computer. During the verification test, data of mock shelters entered online were tabulated quickly and accurately on a mock disaster headquarters' computer. Likewise, data entered offline also were tabulated quickly on the mock disaster headquarters' computer when the tablet device was moved into an online environment. The RASECC-GM, a system for rapidly assessing the condition of evacuation centers, was developed. Tests verify that users of the system would be able to easily, quickly, and accurately assess vast quantities of data from multiple shelters in a major disaster and immediately manage the inputted data at the disaster headquarters. Ishii T , Nakayama M , Abe M , Takayama S , Kamei T , Abe Y , Yamadera J , Amito K , Morino K . Development and verification of a mobile shelter assessment system "Rapid Assessment System of Evacuation Center Condition featuring Gonryo and Miyagi (RASECC-GM)" for major disasters. Prehosp Disaster Med. 2016;31(5):539-546.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its 11th annual city-wide mock trial competition, this instructional handout provides material for a civil trial over a disputed discriminatory termination of employment. Vincent Taylor claims that the Lance Memorial Hospital for Women fired him on the basis of his sex. The hospital…
Determination of extra trajectory parameters of projectile layout motion
NASA Astrophysics Data System (ADS)
Ishchenko, A.; Burkin, V.; Faraponov, V.; Korolkov, L.; Maslov, E.; Diachkovskiy, A.; Chupashev, A.; Zykova, A.
2017-11-01
The paper presents a brief description of the experimental track developed and implemented on the base of the RIAMM TSU for external trajectory investigations on determining the main aeroballistic parameters of various shapes projectiles, in the wide velocity range. There is comparison between the experimentally obtained dependence of the fin-stabilized projectile mock-up aerodynamic drag coefficient on the Mach number with the 1958 aerodynamic drag law and aerodynamic tests of the same mock-up
Mock-juror evaluations of traditional and ratings-based eyewitness identification evidence.
Sauer, James D; Palmer, Matthew A; Brewer, Neil
2017-08-01
Compared to categorical identifications, culprit likelihood ratings (having the witness rate, for each lineup member, the likelihood that the individual is the culprit) provide a promising alternative for assessing a suspect's likely guilt. Four experiments addressed 2 broad questions about the use of culprit likelihood ratings evidence by mock-jurors. First, are mock-jurors receptive to noncategorical forms of identification evidence? Second, does the additional information provided by ratings (relating to discrimination) affect jurors' evaluations of the identification evidence? Experiments 1 and 1A manipulated confidence (90% vs. 50%) and discrimination (good, poor, no information) between participants. Evaluations were influenced by confidence, but not discrimination. However, a within-participant manipulation of discrimination (Experiment 2) demonstrated that evidence of good discrimination enhanced the persuasiveness of moderate levels of confidence, while poor discrimination reduced the persuasiveness of high levels of confidence. Thus, participants can interpret ratings-based evidence, but may not intuit the discrimination information when evaluating ratings for a single identification procedure. Providing detailed instructions about interpreting ratings produced clear discrimination effects when evaluating a single identification procedure (Experiment 3). Across 4 experiments, we found no evidence that mock-jurors perceived noncategorical identification evidence to be less informative than categorical evidence. However, jurors will likely benefit from instruction when interpreting ratings provided by a single witness. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Shirasaki, Masato; Takada, Masahiro; Miyatake, Hironao; Takahashi, Ryuichi; Hamana, Takashi; Nishimichi, Takahiro; Murata, Ryoma
2017-09-01
We develop a method to simulate galaxy-galaxy weak lensing by utilizing all-sky, light-cone simulations and their inherent halo catalogues. Using the mock catalogue to study the error covariance matrix of galaxy-galaxy weak lensing, we compare the full covariance with the 'jackknife' (JK) covariance, the method often used in the literature that estimates the covariance from the resamples of the data itself. We show that there exists the variation of JK covariance over realizations of mock lensing measurements, while the average JK covariance over mocks can give a reasonably accurate estimation of the true covariance up to separations comparable with the size of JK subregion. The scatter in JK covariances is found to be ∼10 per cent after we subtract the lensing measurement around random points. However, the JK method tends to underestimate the covariance at the larger separations, more increasingly for a survey with a higher number density of source galaxies. We apply our method to the Sloan Digital Sky Survey (SDSS) data, and show that the 48 mock SDSS catalogues nicely reproduce the signals and the JK covariance measured from the real data. We then argue that the use of the accurate covariance, compared to the JK covariance, allows us to use the lensing signals at large scales beyond a size of the JK subregion, which contains cleaner cosmological information in the linear regime.
Bucknell On-Line Circulation System; A Library Staff View.
ERIC Educational Resources Information Center
Rivoire, Helena
The Bucknell On-Line Circulation System (BLOCS) was designed to meet the requirements of a circulation system of the Ellen Clarke Bertrand Library of Bucknell University. The requirements for an automated system were, in sum: (1) a system whose operations were not only reliable but simple enough for student assistants (many of whom work only 10…
[The present and future state of minimized extracorporeal circulation].
Meng, Fan; Yang, Ming
2013-05-01
Minimized extracorporeal circulation improved in the postoperative side effects of conventional extracorporeal circulation is a kind of new extracorporeal circulation. This paper introduces the principle, characteristics, applications and related research of minimized extracorporeal circulation. For the problems of systemic inflammatory response syndrome and limited assist time, the article proposes three development direction including system miniaturization and integration, pulsatile blood pump and the adaptive control by human parameter identification.
Superconductor rotor cooling system
Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.
2004-11-02
A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.
Superconductor rotor cooling system
Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.
2002-01-01
A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.
Soman, Ambalathumpara Raman; Sundararaj, Gopalswamy
2015-01-01
In the current industrial scenario there is a serious need for formulating strategies to handle hazardous substances in the safest way. Manufacture, storage, and use of hazardous substances pose a serious risk to industry, people, and the environment. Accidental release of toxic chemicals can lead to emergencies. An emergency response plan (ERP) is inevitable to minimize the adverse effects of such releases. The on-site emergency plan is an integral component of any process safety and risk management system. This paper deals with an on-site emergency response plan for a chlorine manufacturing industry. It was developed on the basis of a previous study on chlorine release and a full scale mock drill has been conducted for testing the plan. Results indicated that properly trained personnel can effectively handle each level of incidents occurring in the process plant. As an extensive guideline to the district level government authorities for off-site emergency planning, risk zone has also been estimated with reference to a chlorine exposure threshold of 3 ppm. PMID:26171416
Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel
2014-09-01
Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow during exercise without causing pulmonary venous congestion. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Pediatric disaster triage education and skills assessment: a coalition approach.
Kenningham, Katherine; Koelemay, Kathryn; King, Mary A
2014-01-01
This study aims to 1) demonstrate one method of pediatric disaster preparedness education using a regional disaster coalition organized workshop and 2) evaluate factors reflecting the greatest shortfall in pediatric mass casualty incident (MCI) triage skills in a varied population of medical providers in King County, WA. Educational intervention and cross-sectional survey. Pediatric disaster preparedness conference created de novo and offered by the King County Healthcare Coalition, with didactic sessions and workshops including a scored mock pediatric MCI triage. Ninety-eight providers from throughout the King County, WA, region selected by their own institutions following invitation to participate, with 88 completing exit surveys. Didactic lectures regarding pediatric MCI triage followed by scored exercises. Mock triage scores were analyzed and compared according to participant characteristics and workplace environment. A half-day regional pediatric disaster preparedness educational conference convened in September 2011 by the King County Healthcare Coalition in partnership with regional pediatric experts was so effective and well-received that it has been rescheduled yearly (2012 and 2013) and has expanded to three Washington State venues sponsored by the Washington State Department of Health. Emergency department (ED) or intensive care unit (ICU) employment and regular exposure to pediatric patients best predicted higher mock pediatric MCI triage scores (ED/ICU 80 percent vs non-ED/ICU 73 percent, p = 0.026; regular pediatric exposure 80 percent vs less exposure 77 percent, p = 0.038, respectively). Pediatric Advanced Life Support training was not found to be associated with improved triage performance, and mock patients whose injuries were not immediately life threatening tended to be over-triaged (observed trend). A regional coalition can effectively organize member hospitals and provide education for focused populations using specialty experts such as pediatricians. Providers working in higher acuity environments and those with regular pediatric patient exposure perform better mock pediatric MCI triage than their counterparts after just-in-time training. Pediatric MCI patients with less than life-threatening injuries tended to be over-triaged.
Who Is the Rotten Apple? Mock Jurors' Views of Teacher-Student Sexual Contact.
Anderson, Alissa; Wingrove, Twila; Fox, Paul; McLean, Kyle; Styer, Erin
2018-05-01
The present study investigated mock jurors' ( N = 541) perceptions of a hypothetical case of teacher-student sexual contact. Mock jurors read a brief vignette describing an alleged sexual encounter where the gender and age of both the teacher and student were manipulated. Participants rendered legal decisions (i.e., verdict, degree of guilt, and sentence length), as well as culpability judgments pertaining to both the teacher and the student (i.e., blame, cause, and desire for the sexual contact). In addition, the effects of mock juror gender and attitudes regarding both rape myth acceptance and homophobia were investigated. Teacher gender and both teacher and student age predicted mock jurors' recommended sentences, with male teachers, older teachers, and younger students leading to greater sentences. Overall, student age was most consistently related to multiple culpability judgments, and the culpability judgments regarding the victim were the most consistently predicted by the independent variables. We did not find any evidence of homosexist attitudes, meaning that same-gender teacher-student contact was not judged any differently than opposite-gender contact. Worth noting, we found an interaction such that male students victimized by female teachers were judged to have wanted the contact more than any other gender combination, especially by male participants. The authors discuss these findings in the context of the child sexual abuse (CSA) literature concluding that many of the findings of more prototypical CSA cases extend to the teacher-student context. We also discuss the implications of these findings in terms of gendered judgments of adolescents who are victimized by teachers, possibly decided by legal professionals, school administrators, and jurors themselves. In particular, the three-way gender interaction can be interpreted in the context of stereotypes regarding sexual development marking sexual contact between adolescent males and older females as a "rite of passage" into adulthood.
ORNL Pre-test Analyses of A Large-scale Experiment in STYLE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Paul T; Yin, Shengjun; Klasky, Hilda B
Oak Ridge National Laboratory (ORNL) is conducting a series of numerical analyses to simulate a large scale mock-up experiment planned within the European Network for Structural Integrity for Lifetime Management non-RPV Components (STYLE). STYLE is a European cooperative effort to assess the structural integrity of (non-reactor pressure vessel) reactor coolant pressure boundary components relevant to ageing and life-time management and to integrate the knowledge created in the project into mainstream nuclear industry assessment codes. ORNL contributes work-in-kind support to STYLE Work Package 2 (Numerical Analysis/Advanced Tools) and Work Package 3 (Engineering Assessment Methods/LBB Analyses). This paper summarizes the current statusmore » of ORNL analyses of the STYLE Mock-Up3 large-scale experiment to simulate and evaluate crack growth in a cladded ferritic pipe. The analyses are being performed in two parts. In the first part, advanced fracture mechanics models are being developed and performed to evaluate several experiment designs taking into account the capabilities of the test facility while satisfying the test objectives. Then these advanced fracture mechanics models will be utilized to simulate the crack growth in the large scale mock-up test. For the second part, the recently developed ORNL SIAM-PFM open-source, cross-platform, probabilistic computational tool will be used to generate an alternative assessment for comparison with the advanced fracture mechanics model results. The SIAM-PFM probabilistic analysis of the Mock-Up3 experiment will utilize fracture modules that are installed into a general probabilistic framework. The probabilistic results of the Mock-Up3 experiment obtained from SIAM-PFM will be compared to those results generated using the deterministic 3D nonlinear finite-element modeling approach. The objective of the probabilistic analysis is to provide uncertainty bounds that will assist in assessing the more detailed 3D finite-element solutions and to also assess the level of confidence that can be placed in the best-estimate finiteelement solutions.« less
Maass Forms and Quantum Modular Forms
NASA Astrophysics Data System (ADS)
Rolen, Larry
This thesis describes several new results in the theory of harmonic Maass forms and related objects. Maass forms have recently led to a flood of applications throughout number theory and combinatorics in recent years, especially following their development by the work of Bruinier and Funke the modern understanding Ramanujan's mock theta functions due to Zwegers. The first of three main theorems discussed in this thesis concerns the integrality properties of singular moduli. These are well-known to be algebraic integers, and they play a beautiful role in complex multiplication and explicit class field theory for imaginary quadratic fields. One can also study "singular moduli" for special non-holomorphic functions, which are algebraic but are not necessarily algebraic integers. Here we will explain the phenomenon of integrality properties and provide a sharp bound on denominators of symmetric functions in singular moduli. The second main theme of the thesis concerns Zagier's recent definition of a quantum modular form. Since their definition in 2010 by Zagier, quantum modular forms have been connected to numerous different topics such as strongly unimodal sequences, ranks, cranks, and asymptotics for mock theta functions. Motivated by Zagier's example of the quantum modularity of Kontsevich's "strange" function F(q), we revisit work of Andrews, Jimenez-Urroz, and Ono to construct a natural vector-valued quantum modular form whose components. The final chapter of this thesis is devoted to a study of asymptotics of mock theta functions near roots of unity. In his famous deathbed letter, Ramanujan introduced the notion of a mock theta function, and he offered some alleged examples. The theory of mock theta functions has been brought to fruition using the framework of harmonic Maass forms, thanks to Zwegers. Despite this understanding, little attention has been given to Ramanujan's original definition. Here we prove that Ramanujan's examples do indeed satisfy his original definition.
Shrestha, D; McAuslane, H J; Adkins, S T; Smith, H A; Dufault, N; Webb, S E
2016-08-01
Since 2003, growers of Florida watermelon [Citrullus lanatus (Thunb.) Matsum. and Nakai] have periodically suffered large losses from a disease caused by Squash vein yellowing virus (SqVYV), which is transmitted by the whitefly Middle East-Asia Minor 1 (MEAM1), formerly Bemisia tabaci (Gennadius) biotype B. Common cucurbit weeds like balsam apple (Momordica charantia L.) and smellmelon [Cucumis melo var. dudaim (L.) Naud.] are natural hosts of SqVYV, and creeping cucumber (Melothria pendula L.) is an experimental host. Study objectives were to compare these weeds and 'Mickylee' watermelon as sources of inoculum for SqVYV via MEAM1 transmission, to determine weed susceptibility to SqVYV, and to evaluate whitefly settling and oviposition behaviors on infected vs. mock-inoculated (inoculated with buffer only) creeping cucumber leaves. We found that the lowest percentage of watermelon recipient plants was infected when balsam apple was used as a source of inoculum. Watermelon was more susceptible to infection than balsam apple or smellmelon. However, all weed species were equally susceptible to SqVYV when inoculated by whitefly. For the first 5 h after release, whiteflies had no preference to settle on infected vs. mock-inoculated creeping cucumber leaves. After 24 h, whiteflies preferred to settle on mock-inoculated leaves, and more eggs were laid on mock-inoculated creeping cucumber leaves than on SqVYV-infected leaves. The transmission experiments (source of inoculum and susceptibility) show these weed species as potential inoculum sources of the virus. The changing settling preference of whiteflies from infected to mock-inoculated plants could lead to rapid spread of virus in the agroecosystem. Published by Oxford University Press on behalf of Entomological Society of America 2016. This work is written by US Government employees and is in the public domain in the United States.
Boman, Inga-Lill; Persson, Ann-Christine; Bartfai, Aniko
2016-03-07
This project Smart Assisted Living involving Informal careGivers++ (SALIG) intends to develop an ICT-based device for persons with cognitive impairment combined with remote support possibilities for significant others and formal caregivers. This paper presents the identification of the target groups' needs and requirements of such device and the evaluation of the first mock-up, demonstrated in a tablet. The inclusive design method that includes end-users in the design process was chosen. First, a scoping review was conducted in order to examine the target group's need of an ICT-based device, and to gather recommendations regarding its design and functionalities. In order to capture the users' requirements of the design and functionalities of the device three targeted focus groups were conducted. Based on the findings from the publications and the focus groups a user requirement specification was developed. After that a design concept and a first mock-up was developed in an iterative process. The mock-up was evaluated through interviews with persons with cognitive impairment, health care professionals and significant others. Data were analysed using content analysis. Several useful recommendations of the design and functionalities of the SALIG device for persons with cognitive impairment were identified. The main benefit of the mock-up was that it was a single device with a set of functionalities installed on a tablet and designed for persons with cognitive impairment. An additional benefit was that it could be used remotely by significant others and formal caregivers. The SALIG device has the potentials to facilitate everyday life for persons with cognitive impairment, their significant others and the work situation for formal caregivers. The results may provide guidance in the development of different types of technologies for the target population and for people with diverse disabilities. Further work will focus on developing a prototype to be empirically tested by persons with cognitive impairment, their significant others and formal caregivers.
Huang, Huan; Yang, Ming; Lu, Cunyue; Xu, Liang; Zhuang, Xiaoqi; Meng, Fan
2013-10-01
Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
Yurimoto, Terumi; Hara, Shintaro; Isoyama, Takashi; Saito, Itsuro; Ono, Toshiya; Abe, Yusuke
2016-09-01
Estimation of pressure and flow has been an important subject for developing implantable artificial hearts. To realize real-time viscosity-adjusted estimation of pressure head and pump flow for a total artificial heart, we propose the table estimation method with quasi-pulsatile modulation of rotary blood pump in which systolic high flow and diastolic low flow phased are generated. The table estimation method utilizes three kinds of tables: viscosity, pressure and flow tables. Viscosity is estimated from the characteristic that differential value in motor speed between systolic and diastolic phases varies depending on viscosity. Potential of this estimation method was investigated using mock circulation system. Glycerin solution diluted with salty water was used to adjust viscosity of fluid. In verification of this method using continuous flow data, fairly good estimation could be possible when differential pulse width modulation (PWM) value of the motor between systolic and diastolic phases was high. In estimation under quasi-pulsatile condition, inertia correction was provided and fairly good estimation was possible when the differential PWM value was high, which was not different from the verification results using continuous flow data. In the experiment of real-time estimation applying moving average method to the estimated viscosity, fair estimation could be possible when the differential PWM value was high, showing that real-time viscosity-adjusted estimation of pressure head and pump flow would be possible with this novel estimation method when the differential PWM value would be set high.
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its ninth annual city-wide mock trial competition, this instructional handout provides the material for a civil trial over housing discrimination. The plaintiffs are an unmarried couple with a disabled child whose application to live at Waterfront Gardens, a property owned by Potomac…
Mock Institutional Review Board: Promoting Analytical and Reasoning Skills in Research Ethics.
Dols, Jean Dowling; Hoke, Mary M; Rauschhuber, Maureen L
Although it is critical that nurses possess ethical reasoning skills for research, there is limited information on effective strategies to develop these skills in graduate health care students. A research study analyzing educational interventions including the effect of online human subjects training followed by a mock institutional review board simulation demonstrated that knowledge acquisition is not enough to acquire the ethical reasoning skills needed to implement health care research. Situational context is also needed to envision the application of ethical principles.
2011-07-01
control MDCK cells treated with IBMX and forskolin and then CFTR-Inh172 at the indicated times is shown. (c) A similar representative trace of mock...initiate CFTR-mediated secretion, CFTR-expressing and mock-transduced MDCK cells were treated with the cAMP agonists IBMX and forskolin , and the...2c. In CFTR-expressing cells there was generally an early peak in Isc within 1-2 min following forskolin /IBMX treatment, followed by a lower plateau
ERIC Educational Resources Information Center
National Inst. for Citizen Education in the Law, Washington, DC.
Prepared by the District of Columbia Street Law Project for its annual city-wide mock trial competition, this instructional handout provides material for a civil trial over a claim for damages. During an argument, a friend pushed Nelson Floyd against the railing of a porch. Falling onto the concrete below, Nelson was injured with a broken shin…
NASA Technical Reports Server (NTRS)
Wick, Bradford, H.; Graham, David
1948-01-01
This report contains the results of the investigation of the aerodynamic characteristics of the flying mock-up of the Consolidated Vultee XP-92 airplane as conducted in the Ames 40- by 80-foot wind tunnel, Data are presented for test conditions which would give information as to the limits of stability and controllability, and also, the effect of Reynolds number. No analysis of the data has been made.
Sandia/NM Available Mock Warhead Container Inventory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brotz, Jay Kristoffer
The real H1514 Shipping and Storage Container is an environmentally sealed and desiccated aluminum drum-type container designed to transport the W88/Mk5 Reentry Body Assembly. The H1514 is cylindrical except for a portion of its base, which is 36" square and 3" high and contains the forklift openings. Our mock H1514 retains the dimensions and shape of the real H1514 in a lighter form that is not sealed and does not have ports for desiccation.
1980-05-01
performed on the TOM-T Turret Mock- Up . Those marked with a number symbol (#) can be done on the TOM-T Programmable Maintenance Trainer. Tasks with both...an asterisk and a number symbol (*/#) are those which can be performed partially on the turret mock- up and partially on the programmable trainer...time, the tasks serve as prerequisites to troubleshooting. With the exception of setting- up , testing, and shutting-down the STE/XMI test set, and
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183519 (3 Nov. 2010) --- NASA astronauts Doug Hurley, STS-135 pilot; and Sandy Magnus, mission specialist, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
2011-06-29
JSC2011-E-060140 (29 June 2011) --- NASA astronaut Rex Walheim laughs with his crewmates as STS-135 commander Chris Ferguson gets a refresher on the use of the waste management system on the International Space Station as the crew trains at NASA?s Johnson Space Center June 29, 2011. The day's training marked the crew's final scheduled sessions in the Space Vehicle Mock-up Facility at JSC. Photo credit: NASA Photo/Houston Chronicle, Smiley N. Pool
46 CFR 56.50-45 - Circulating pumps.
Code of Federal Regulations, 2010 CFR
2010-10-01
... APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-45 Circulating pumps. (a) A main circulating pump and emergency means for circulating water through the main condenser shall be provided. The... circulating pump and the condenser. (b) Independent sea suctions shall be provided for the main circulating...
ISS Phase One Activities and Manufacturing in Russia, France and Italy
1996-10-07
Photographs documenting International Space Station (ISS) Phase One activities at the Russian Space Agency's (RSA) Gagarin Cosmonaut Training Center, Korolov Mission Control Center and Zvezda; and ISS and Soyuz manufacturing at RSA's Khrunichev Design Center and RSC Energiya in Moscow, Russia, the French Space Agency's (CNES) INTESPACE facility in Toulouse, France, and the Italian Space Agency's (ASI) Alenia Spazio facility in Torino, Italy. Photographs were taken by Johnson Space Center Imagery and Publications Office contractors travelling from October 7 to November 4, 1996. Includes: VIEWS FROM RSC ENERGIYA'S SPACE MUSEUM: Room with a Buran model and photographic displays (17372-374). Salyut Space Station mock-up (17376). Russian propulsion engines on display (17377-378). Russian spacecraft on display (17375, 17387-398). Graphic displays (17399-405). VIEWS FROM RSC ENERGIYA MANUFACTURING FACILITIES: Unidentified facility (17379). Mir 24 crew member Michael C. Foale, suited in a Soyuz pressure suit, ingresses the Soyuz TM-26 flight article at RSC Energiya for a fit check (17380-381). Closeups of Foale inside the Soyuz during the fit check (17382-383, 17466-467). Overhead views of RSC Energiya's Building 444 manufacturing floor where docking modules and Soyuz TM spacecraft are built (17495-498). Technicians on the Building 444 manufacturing floor assembling probe and drogue docking modules (17499-500, 17504). Technicians assembling Soyuz spacecraft (17437-439). Views of other Soyuz spacecraft (17440-441). Androgynous Peripheral Docking System (APDS) mock-up (17501-503). Closeups of a control panel, possibly for the APDS mock-up (17519-528). VIEWS FROM ZVEZDA, RSA CONTRACTOR FOR SUIT DESIGN AND SOYUZ SEAT LINERS: Mir 24 crew member Foale dons a "penguin" flight suit for a fit check (17454-456). Zvezda personnel adjust Foale's Soyuz seat and seat liner (17442). Closeup of Foale, suited in a Soyuz pressure suit, sitting on a chair (17444). Zvezda personnel strap pressure-suited Foale into his Soyuz seat (17443, 17445, 17450). Views of Foale in his Soyuz seat during a pressurized pressure suit fit check (17451-453). Views looking into a vacuum chamber where Foale, wearing pressure suit, is strapped into his Soyuz seat (17466-467). Views of Zvezda personnel working at the vacuum chamber control station during the vacuum chamber suit test (17468-471). VIEWS FROM KHRUNICHEV DESIGN CENTER: Views of a green ISS Functional Cargo Block (FGB) test article on the manufacturing floor (17529, 17532-536, 17540-544). Views of an ISS Service Module (SM) test article on the manufacturing floor (17530-531, 17537, 17539). Closeup of the SM test article docking sphere (17538). Views of the FGB flight article on the manufacturing floor during systems tests (17545-548, 17550-567). Views of technicians conducting the FGB systems tests (17549, 17557). VIEWS FROM GAGARIN COSMONAUT TRAINING CENTER: NASA astronauts work out in the cosmonaut gym at Gagarin: Closeup of ISS 2R Expedition Commander William Shepherd on a weight machine (17384). Shepherd and an unidentified man with back to camera work out with dumbbells (17386). Shepherd does pull-ups (17447). Closeup of Foale on an exercise machine (17385). Closeups of Foale exercising arms on a cycle ergometer and a weight machine (17415, 17448-449). Foale exercises on a Nordic Track (17416). Closeup of Mir 23 crew member Jerry Linenger exercising arms (17417). Wendy Lawrence exercises with dumbbells (17418). Closeup of Lawrence in a handstand position (17419). David Wolf works out on a leg press machine (17446). Views of the Mir Space Station mock-up at Gagarin: Interior views of the Mir Base Module mock-up looking toward the transfer compartment (17421-425). Mir Base Module living area mock-up (17420). Overall views of the Base Module mock-up central control station (17426-427, 17505). Closeups of switch panels on the central control station (17428-436, 17506-518). Other views from Gagarin: Personnel work at an unidentified test/trainer control station (17472-473). Linenger sits at a table next to an RSA trainer during a Mir 23 meeting (17475-476). Out-of-focus view of two subjects in the Soyuz trainer (17474). Foale examines a Mir Complex EVA Suit (Orlan) with RSA trainers during an EVA suit training class (17492-494). VIEWS FROM KOROLOV MISSION CONTROL CENTER: Various views of personnel working in the NASA Consulting Room and/or PAO Consulting Room at Korolov Mission Control Center (17457-463). VIEWS FROM INTESPACE: Exterior views of an ISS Mini Pressurized Logistics Module (MPLM) structural test article (STA) during testing at INTESPACE (17406-409, 17477, 17482-484). Technicians install hatch on the MPLM STA (17410-414). Interior views of the MPLM STA (17478-481). VIEWS FROM ALENIA SPAZIO: Closeups of MPLM flight article #1 side panels during milling and refining at Alenia Spazio (17485-488). Workers process MPLM parts at milling machines (17489-491).
Heat transfer and hydrodynamic analysis in an industrial circulating fluidized bed boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Maggio, T.; Piedfer, O.; Jestin, L.
In order to scale-up Circulating Fluidized Bed boilers (up to 600 MWe), Electricite de France has initiated a Research and Development program including: laboratory work on mock-up, numerical modeling and on-site tests in the 125 MWe CFB Emile Huchet plant. This paper is devoted to on-site measurements analysis in two main components of this industrial unit: the external fluidized bed heat exchangers and the backpass. This study particularly concerns hydrodynamics and heat transfer with the final target of developing a physical model of a CFB unit. The first part of this paper describes the specific instrumentation set up on externalmore » fluidized bed heat exchangers. The comparison between experimental data collected on these heat exchangers and the theoretical heat transfer models mainly used, shows a great difference about the value of the overall heat transfer coefficient. To explain this discrepancy, the particle flow pattern initially used in the thermal balance calculation is modified and a solid bypass is introduced. The analysis of the by-pass behavior, connected to the geometrical and operating parameters of each exchanger, confirms the particle flow pattern suggested. The second part of this paper shows an analysis of the specific measurements set up on the backpass to study heat transfer. The physical model of heat transfer used to assess the importance of each convection, radiation and conduction components is presented. This model allows one to assess the influence of heat exchangers design on heat transfer. Moreover, the analysis of heat transfer variations during sweeping cycles gives the amount of dust that is removed from the heat exchanger tubes. These results are used to evaluate the amount of power that can be recovered by optimizing both design and sweeping of the backpass.« less
Kolyva, Christina; Biglino, Giovanni; Pepper, John R; Khir, Ashraf W
2012-03-01
A mock circulatory system (MCS) was designed to replicate a physiological environment for in vitro testing and was assessed with the intra-aortic balloon pump (IABP). The MCS was comprised of an artificial left ventricle (LV), connected to a 14-branch polyurethane-compound aortic model. Physiological distribution of terminal resistance and compliance according to published data was implemented with capillary tubes of different sizes and syringes of varying air volume, respectively, fitted at the outlets of the branches. The ends of the aortic branches were connected to a common tube representing the venous system and an overhead reservoir provided atrial pressure. An IABP operating a 40-cc balloon was set to counterpulsate with the LV. Total arterial compliance of the system was 0.94 mL/mm Hg and total arterial resistance was 20.3 ± 3.3 mm Hg/L/min. At control, physiological flow distribution was achieved and both mean and phasic aortic pressure and flow were physiological. With the IABP, aortic pressure exhibited the major features of counterpulsation: diastolic augmentation during inflation, inflection point at onset of deflation, and end-diastolic reduction at the end of deflation. The contribution of balloon inflation and deflation was also evident on the aortic flow pattern. This MCS was verified to be suitable for IABP testing and with further adaptations it could be used for studying other hemodynamic problems and ventricular assist devices. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Mock Target Window OTR and IR Design and Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wass, Alexander Joseph
In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allowsmore » us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.« less
A Gaia DR2 Mock Stellar Catalog
NASA Astrophysics Data System (ADS)
Rybizki, Jan; Demleitner, Markus; Fouesneau, Morgan; Bailer-Jones, Coryn; Rix, Hans-Walter; Andrae, René
2018-07-01
We present a mock catalog of Milky Way stars, matching in volume and depth the content of the Gaia data release 2 (GDR2). We generated our catalog using Galaxia, a tool to sample stars from a Besançon Galactic model, together with a realistic 3D dust extinction map. The catalog mimics the complete GDR2 data model and contains most of the entries in the Gaia source catalog: five-parameter astrometry, three-band photometry, radial velocities, stellar parameters, and associated scaled nominal uncertainty estimates. In addition, we supplemented the catalog with extinctions and photometry for non-Gaia bands. This catalog can be used to prepare GDR2 queries in a realistic runtime environment, and it can serve as a Galactic model against which to compare the actual GDR2 data in the space of observables. The catalog is hosted through the virtual observatory GAVO’s Heidelberg data center (http://dc.g-vo.org/tableinfo/gdr2mock.main) service, and thus can be queried using ADQL as for GDR2 data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaurov, Alexander A., E-mail: kaurov@uchicago.edu
The methods for studying the epoch of cosmic reionization vary from full radiative transfer simulations to purely analytical models. While numerical approaches are computationally expensive and are not suitable for generating many mock catalogs, analytical methods are based on assumptions and approximations. We explore the interconnection between both methods. First, we ask how the analytical framework of excursion set formalism can be used for statistical analysis of numerical simulations and visual representation of the morphology of ionization fronts. Second, we explore the methods of training the analytical model on a given numerical simulation. We present a new code which emergedmore » from this study. Its main application is to match the analytical model with a numerical simulation. Then, it allows one to generate mock reionization catalogs with volumes exceeding the original simulation quickly and computationally inexpensively, meanwhile reproducing large-scale statistical properties. These mock catalogs are particularly useful for cosmic microwave background polarization and 21 cm experiments, where large volumes are required to simulate the observed signal.« less
Performance of Control System Using Microcontroller for Sea Water Circulation
NASA Astrophysics Data System (ADS)
Indriani, A.; Witanto, Y.; Pratama, A. S.; Supriyadi; Hendra; Tanjung, A.
2018-02-01
Now a day control system is very important rule for any process. Control system have been used in the automatic system. Automatic system can be seen in the industrial filed, mechanical field, electrical field and etc. In industrial and mechanical field, control system are used for control of motion component such as motor, conveyor, machine, control of process made of product, control of system and soon. In electrical field, control system can met for control of electrical system as equipment or part electrical like fan, rice cooker, refrigerator, air conditioner and etc. Control system are used for control of temperature and circulation gas, air and water. Control system of temperature and circulation of water also can be used for fisher community. Control system can be create by using microcontroller, PLC and other automatic program [1][2]. In this paper we will focus on the close loop system by using microcontroller Arduino Mega to control of temperature and circulation of sea water for fisher community. Performance control system is influenced by control equipment, sensor sensitivity, test condition, environment and others. The temperature sensor is measured using the DS18S20 and the sea water clarity sensor for circulation indicator with turbidity sensor. From the test results indicated that this control system can circulate sea water and maintain the temperature and clarity of seawater in a short time.
Zhang, Fuquan; Hopwood, Paul; Abrams, Charles C.; Downing, Alison; Murray, Frazer; Talbot, Richard; Archibald, Alan; Lowden, Stewart; Dixon, Linda K.
2006-01-01
We used a porcine microarray containing 2,880 cDNAs to investigate the response of macrophages to infection by a virulent African swine fever virus (ASFV) isolate, Malawi LIL20/1. One hundred twenty-five targets were found to be significantly altered at either or both 4 h and 16 h postinfection compared with targets after mock infection. These targets were assigned into three groups according to their temporal expression profiles. Eighty-six targets showed increased expression levels at 4 h postinfection but returned to expression levels similar to those in mock-infected cells at 16 h postinfection. These encoded several proinflammatory cytokines and chemokines, surface proteins, and proteins involved in cell signaling and trafficking pathways. Thirty-four targets showed increased expression levels at 16 h postinfection compared to levels at 4 h postinfection and in mock-infected cells. One host gene showed increased expression levels at both 4 and 16 h postinfection compared to levels in mock-infected cells. The microarray results were validated for 12 selected genes by quantitative real-time PCR. Levels of protein expression and secretion were measured for two proinflammatory cytokines, interleukin 1β and tumor necrosis factor alpha, during a time course of infection with either the virulent Malawi LIL20/1 isolate or the OUR T88/3 nonpathogenic isolate. The results revealed differences between these two ASFV isolates in the amounts of these cytokines secreted from infected cells. PMID:17041222
Lindsay, Sally; McDougall, Carolyn; Sanford, Robyn; Menna-Dack, Dolly; Kingsnorth, Shauna; Adams, Tracey
2015-01-01
To assess performance differences in a mock job interview and workplace role-play exercise for youth with disabilities compared to their typically developing peers. We evaluated a purposive sample of 31 youth (15 with a physical disability and 16 typically developing) on their performance (content and delivery) in employment readiness role-play exercises. Our findings show significant differences between youth with disabilities compared to typically developing peers in several areas of the mock interview content (i.e. responses to the questions: "tell me about yourself", "how would you provide feedback to someone not doing their share" and a problem-solving scenario question) and delivery (i.e. voice clarity and mean latency). We found no significant differences in the workplace role-play performances of youth with and without disabilities. Youth with physical disabilities performed poorer in some areas of a job interview compared to their typically developing peers. They could benefit from further targeted employment readiness training. Clinicians should: Coach youth with physical disability on how to "sell" their abilities to potential employers and encourage youth to get involved in volunteer activities and employment readiness training programs. Consider using mock job interviews and other employment role-play exercises as assessment and training tools for youth with physical disabilities. Involve speech pathologists in the development of employment readiness programs that address voice clarity as a potential delivery issue.
VizieR Online Data Catalog: A cosmic void catalog of SDSS DR12 BOSS galaxies (Mao+, 2017)
NASA Astrophysics Data System (ADS)
Mao, Q.; Berlind, A. A.; Scherrer, R. J.; Neyrinck, M. C.; Scoccimarro, R.; Tinker, J. L.; McBride, C. K.; Schneider, D. P.; Pan, K.; Bizyaev, D.; Malanushenko, E.; Malanushenko, V.
2017-08-01
We present a cosmic void catalog using the large-scale structure galaxy catalog from the Baryon Oscillation Spectroscopic Survey (BOSS). This galaxy catalog is part of the Sloan Digital Sky Survey (SDSS) Data Release 12 and is the final catalog of SDSS-III. We take into account the survey boundaries, masks, and angular and radial selection functions, and apply the ZOBOV (Neyrinck 2008MNRAS.386.2101N) void finding algorithm to the Galaxy catalog. We identify a total of 10643 voids. After making quality cuts to ensure that the voids represent real underdense regions, we obtain 1228 voids with effective radii spanning the range 20-100h-1Mpc and with central densities that are, on average, 30% of the mean sample density. We release versions of the catalogs both with and without quality cuts. We discuss the basic statistics of voids, such as their size and redshift distributions, and measure the radial density profile of the voids via a stacking technique. In addition, we construct mock void catalogs from 1000 mock galaxy catalogs, and find that the properties of BOSS voids are in good agreement with those in the mock catalogs. We compare the stellar mass distribution of galaxies living inside and outside of the voids, and find no large difference. These BOSS and mock void catalogs are useful for a number of cosmological and galaxy environment studies. (1 data file).
Hierarchical Bayesian inference of the initial mass function in composite stellar populations
NASA Astrophysics Data System (ADS)
Dries, M.; Trager, S. C.; Koopmans, L. V. E.; Popping, G.; Somerville, R. S.
2018-03-01
The initial mass function (IMF) is a key ingredient in many studies of galaxy formation and evolution. Although the IMF is often assumed to be universal, there is continuing evidence that it is not universal. Spectroscopic studies that derive the IMF of the unresolved stellar populations of a galaxy often assume that this spectrum can be described by a single stellar population (SSP). To alleviate these limitations, in this paper we have developed a unique hierarchical Bayesian framework for modelling composite stellar populations (CSPs). Within this framework, we use a parametrized IMF prior to regulate a direct inference of the IMF. We use this new framework to determine the number of SSPs that is required to fit a set of realistic CSP mock spectra. The CSP mock spectra that we use are based on semi-analytic models and have an IMF that varies as a function of stellar velocity dispersion of the galaxy. Our results suggest that using a single SSP biases the determination of the IMF slope to a higher value than the true slope, although the trend with stellar velocity dispersion is overall recovered. If we include more SSPs in the fit, the Bayesian evidence increases significantly and the inferred IMF slopes of our mock spectra converge, within the errors, to their true values. Most of the bias is already removed by using two SSPs instead of one. We show that we can reconstruct the variable IMF of our mock spectra for signal-to-noise ratios exceeding ˜75.
NASA Astrophysics Data System (ADS)
Moore, Andrew M.; Jacox, Michael G.; Crawford, William J.; Laughlin, Bruce; Edwards, Christopher A.; Fiechter, Jérôme
2017-08-01
Data assimilation is now used routinely in oceanography on both regional and global scales for computing ocean circulation estimates and for making ocean forecasts. Regional ocean observing systems are also expanding rapidly, and observations from a wide array of different platforms and sensor types are now available. Evaluation of the impact of the observing system on ocean circulation estimates (and forecasts) is therefore of considerable interest to the oceanographic community. In this paper, we quantify the impact of different observing platforms on estimates of the California Current System (CCS) spanning a three decade period (1980-2010). Specifically, we focus attention on several dynamically related aspects of the circulation (coastal upwelling, the transport of the California Current and the California Undercurrent, thermocline depth and eddy kinetic energy) which in many ways describe defining characteristics of the CCS. The circulation estimates were computed using a 4-dimensional variational (4D-Var) data assimilation system, and our analyses also focus on the impact of the different elements of the control vector (i.e. the initial conditions, surface forcing, and open boundary conditions) on the circulation. While the influence of each component of the control vector varies between different metrics of the circulation, the impact of each observing system across metrics is very robust. In addition, the mean amplitude of the circulation increments (i.e. the difference between the analysis and background) remains relatively stable throughout the three decade period despite the addition of new observing platforms whose impact is redistributed according to the relative uncertainty of observations from each platform. We also consider the impact of each observing platform on CCS circulation variability associated with low-frequency climate variability. The low-frequency nature of the dominant climate modes in this region allows us to track through time the impact of each observation on the circulation, and illustrates how observations from some platforms can influence the circulation up to a decade into the future.
Automated Circulation Systems as a Source of Secondary Information.
ERIC Educational Resources Information Center
Chapin, Giny Ziegler
This report looks at the use of public library online circulation systems for the generation of in-house secondary information--such as statistical reports and mailing lists--and also considers problems in maintaining confidentiality of patron records when using online circulation systems. Based on a survey of the literature, general information…
On-Line Circulation: University of Guelph Library. Report No. 8.
ERIC Educational Resources Information Center
Beckman, Margaret; And Others
This report describes the development, design, and evaluation of an online circulation system at the University of Guelph, Ontario. A 1976 study identified the specific problems or inadequacies of the existing circulation system and specified design requirements for a new online system. This 1978 report is divided into six parts: (1) historical…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... electrically-powered devices used in central HVAC systems for the purposes of circulating air through ductwork...- powered device used in a central HVAC system for the purpose of circulating air through ductwork. DOE... included single-phase, electrically-powered devices that circulate air through ductwork in HVAC systems...
Lu, David; Graf, Ryon P.; Harvey, Melissa; Madan, Ravi A.; Heery, Christopher; Marte, Jennifer; Beasley, Sharon; Tsang, Kwong Y.; Krupa, Rachel; Louw, Jessica; Wahl, Justin; Bales, Natalee; Landers, Mark; Marrinucci, Dena; Schlom, Jeffrey; Gulley, James L.; Dittamore, Ryan
2015-01-01
Retrospective analysis of patient tumour samples is a cornerstone of clinical research. CTC biomarker characterization offers a non-invasive method to analyse patient samples. However, current CTC technologies require prospective blood collection, thereby reducing the ability to utilize archived clinical cohorts with long-term outcome data. We sought to investigate CTC recovery from frozen, archived patient PBMC pellets. Matched samples from both mCRPC patients and mock samples, which were prepared by spiking healthy donor blood with cultured prostate cancer cell line cells, were processed “fresh” via Epic CTC Platform or from “frozen” PBMC pellets. Samples were analysed for CTC enumeration and biomarker characterization via immunofluorescent (IF) biomarkers, fluorescence in-situ hybridization (FISH) and CTC morphology. In the frozen patient PMBC samples, the median CTC recovery was 18%, compared to the freshly processed blood. However, abundance and localization of cytokeratin (CK) and androgen receptor (AR) protein, as measured by IF, were largely concordant between the fresh and frozen CTCs. Furthermore, a FISH analysis of PTEN loss showed high concordance in fresh vs. frozen. The observed data indicate that CTC biomarker characterization from frozen archival samples is feasible and representative of prospectively collected samples. PMID:28936240
A Low-Cost, Efficient, Machine-Assisted Manual Circulation System
ERIC Educational Resources Information Center
Stangl, Peter
1975-01-01
A circulation system uses plastic embossed user cards, an addressograph electric imprinter, a copy of the catalog card as a book card, and a pocket imprinted by the user's card and holding the book card during circulation. (LS)
NASA Technical Reports Server (NTRS)
Bremmer, D. A.
1986-01-01
The feasibility of some off-the-shelf microprocessors and state-of-art software is assessed (1) as a development system for the principle investigator (pi) in the design of the experiment model, (2) as an example of available technology application for future PI's experiments, (3) as a system capable of being interactive in the PCTC's simulation of the dedicated experiment processor (DEP), preferably by bringing the PI's DEP software directly into the simulation model, (4) as a system having bus compatibility with host VAX simulation computers, (5) as a system readily interfaced with mock-up panels and information displays, and (6) as a functional system for post mission data analysis.
Kumar, Manoj; Liu, Zheng-Ren; Thapa, Laxmi; Wang, Da-Yu; Tian, Rui; Qin, Ren-Yi
2004-08-01
Several studies reported that somatostatin receptor subtypes, especially subtype 2 (SSTR2), exerted their cytostatic and/or cytotoxic effects on various types of tumors. The aim of this study was to investigate the antitumor effect of SSTR2 gene transfer to the pancreatic cancer cell line PC-3 and the mechanisms involved in this effect. The full-length human SSTR2 cDNA was introduced into pancreatic cancer cell line PC-3 by lipofectamine-mediated transfection; positive clones were screened by G418, and stable expression of SSTR2 was detected by the immunohistochemical SABC method and RT-PCR. Athymic mice were separately xenografted with SSTR2-expressing cells (experimental group), vector control, and mock control cells. TUNEL assay was used to determine the apoptotic index (AI) in the tumors of these groups. The immunohistochemical SP method was used to determine expression of apoptosis-regulating genes Bcl-2 and Bax and re-expression of SSTR2 and to assess intratumoral microvessel density (MVD). Moreover, tumor volume and weight were compared among these 3 groups. Restoration of SSTR2 was observed in the experimental group both in vitro and in vivo. The AI was significantly higher in the experimental group (3.39 +/- 0.84%) compared with that in the vector control (0.69 +/- 0.08%) and mock control (0.68 +/- 0.09%) (P < 0.05). MVD was significantly lower in the experimental group (6.30 +/- 1.71) than that in the vector control (12.64 +/- 1.69) and mock control (13.50 +/- 1.86) (P < 0.05). Furthermore, a significant decrease in Bcl-2 and increase in Bax protein expression were detected in the experimental group compared with the vector control and mock control (P < 0.05). A significant negative correlation of protein expression between Bcl-2/Bax ratio and SSTR2 was observed in these tumors (P < 0.05). Tumor volume and weight were significantly decreased in the experimental group compared with the vector control and mock control (P < 0.05) groups. However, no significant differences were observed between the vector control and mock control (P > 0.05). Re-expression of the SSTR2 gene, the expression of which is frequently lost in human pancreatic adenocarcinoma, induces apoptosis, which may be mediated via down-regulation of Bcl-2 and up-regulation of Bax (alteration of Bcl-2/Bax ratio) and inhibits tumor angiogenesis in pancreatic carcinoma, resulting in inhibition of tumor growth.
Operation of a cascade air conditioning system with two-phase loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Yinshan; Wang, Jinliang; Zhao, Futao
A method of operating a heat transfer system includes starting operation of a first heat transfer fluid vapor/compression circulation loop including a fluid pumping mechanism, a heat exchanger for rejecting thermal energy from a first heat transfer fluid, and a heat absorption side of an internal heat exchanger. A first conduit in a closed fluid circulation loop circulates the first heat transfer fluid therethrough. Operation of a second two-phase heat transfer fluid circulation loop is started after starting operation of the first heat transfer fluid circulation loop. The second heat transfer fluid circulation loop transfers heat to the first heatmore » transfer fluid circulation loop through the internal heat exchanger and includes a heat rejection side of the internal heat exchanger, a liquid pump, and a heat exchanger evaporator. A second conduit in a closed fluid circulation loop circulates a second heat transfer fluid therethrough.« less
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183523 (3 Nov. 2010) --- NASA astronauts Rex Walheim (left), STS-135 mission specialist; and Doug Hurley, pilot, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183524 (3 Nov. 2010) --- NASA astronauts Rex Walheim (left), STS-135 mission specialist; and Doug Hurley, pilot, participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284891 (15 Dec. 2009) --- STS-134 crew members participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center. Pictured from the right are NASA astronauts Andrew Feustel, Greg Chamitoff, Michael Fincke, all mission specialists; along with NASA astronaut Gregory H. Johnson, pilot; and European Space Agency astronaut Roberto Vittori, mission specialist.
2016-01-29
Arlington, Virginia 22203-1995 61-9496-A-2-5 ONR May 2014 – April 2015 *Nova Research, Inc., Alexandria, VA Improvised explosive device Detector dog Canine...37 Figure 30. Mass of MeS collected from three subsequent mock dog sniffs above the MODD. .. 37 Figure 31. Vapor concentration...particularly for the detection of HMEs. In 2012, the Office of Naval Research deployed as many as 280 IED Detector Dogs (IDDs) to Afghanistan [1
Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.
Montenegro, Alexandre Campos; Machado, Aldir Nascimento; Depes Gouvêa, Cresus Vinicius
2008-12-01
The aim of this in vitro study was to evaluate the tensile strength of titanium cylinders cemented on stainless steel abutment mock-ups by the Cerazone system. Four types of cements were used: glass ionomer, Fuji I (GC); zinc phosphate, Cimento LS (Vigodent); zinc oxide without eugenol, Rely x Temp NE (3M ESPE); and resin cement, Rely x ARC (3M ESPE). Four experimental groups were formed, each composed of 5 test specimens. Each test specimen consisted of a set of 1 cylinder and 1 stainless steel abutment mock-up. All cements tested were manipulated in accordance with manufacturers' instructions. A static load of 5 Newtons (N) for 2 minutes was used to standardize the procedure. The tensile tests were performed by a mechanical universal testing machine (EMIC DL500MF) at a crosshead speed of 0.5 mm/min. The highest bonding values resulting from the experiment were obtained by Cimento LS (21.86 MPa mean), followed by the resin cement Rely x ARC (12.95 MPa mean), Fuji I (6.89 MPa mean), and Rely x Temp NE (4.71 MPa mean). The results were subjected to analysis of variance (ANOVA) and the Student's t test. The cements differed amongst them as regards tensile strength, with the highest bonding levels recorded with zinc phosphate (Cimento LS) and the lowest with the zinc oxide without eugenol (Rely x Temp NE).
NASA Technical Reports Server (NTRS)
Graham, David
1948-01-01
This report contains the results of the wind tunnel investigation of the pressure distribution on the flying mock-up of the Consolidated Vultee XP-92 airplane. Data are presented for the pressure distribution over the wing, vertical tail and the fuselage, and for the pressure loss and rate of flow through the ducted fuselage. Data are also presented for the calibration of two airspeed indicators, and for the calibration of angle-of-attack and sideslip-angle indicator vanes.
1974-10-01
6-44 102. French onion soup 6-48 103. Strawberry milk shake 6-52 104. Sprite 6-56 105. Broccoli w/mock hollandaise sauce 6-60 106. Parmesan...Sandwich with Brown Gravy Grilled Cheeseburger on Toasted Roll Grilled Hamburger on Toasted Roll. • • < Broccoli with Mock Hollandaise Sauce ...MEAL APPENDIX B NAME/NUMBER ♦Beef Barley Soup _ Croutons > _ ♦Baked Virginia Ham with Pineapple Raisin Sauce _ Grilled Frankfurter on Toasted
System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takaaki Sakai; Yasuhiro Enuma; Takashi Iwasaki
2002-07-01
Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heatmore » removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in a primary circulation path is temporary reduced. However, the natural circulation is recovered by the PRACS system and the out let temperature decreases successfully. (authors)« less
System Analysis for Decay Heat Removal in Lead-Bismuth-Cooled Natural-Circulation Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakai, Takaaki; Enuma, Yasuhiro; Iwasaki, Takashi
2004-03-15
Decay heat removal analyses for lead-bismuth-cooled natural-circulation reactors are described in this paper. A combined multidimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural-circulation reactors. For the preliminary study, transient analysis has been performed for a 300-MW(thermal) lead-bismuth-cooled reactor designed by Argonne National Laboratory. In addition, decay heat removal characteristics of a 400-MW(electric) lead-bismuth-cooled natural-circulation reactor designed by the Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. The primary reactor auxiliary cooling system (PRACS) is prepared for the JNC concept to get sufficient heat removal capacity. During 2000 smore » after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 deg. C because the buoyancy force in a primary circulation path is temporarily reduced. However, the natural circulation is recovered by the PRACS system, and the outlet temperature decreases successfully.« less
A blood circulation model for reference man
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leggett, R.W.; Eckerman, K.F.; Williams, L.R.
This paper describes a dynamic blood circulation model that predicts the movement and gradual dispersal of a bolus of material in the circulation after its intravascular injection into an adult human. The main purpose of the model is to improve the dosimetry of internally deposited radionuclides that decay in the circulation to a significant extent. The total blood volume is partitioned into the blood contents of 24 separate organs or tissues, right heart chambers, left heart chambers, pulmonary circulation, arterial outflow to the systemic tissues (aorta and large arteries), and venous return from the systemic tissues (large veins). As amore » compromise between physical reality and computational simplicity, the circulation of blood is viewed as a system of first-order transfers between blood pools, with the delay time depending on the mean transit time across the pool. The model allows consideration of incomplete, tissue-dependent extraction of material during passage through the circulation and return of material from tissues to plasma.« less
Proceedings of the 2004 NASA/ONR Circulation Control Workshop, Part 1
NASA Technical Reports Server (NTRS)
Jones, Gregory S. (Editor); Joslin, Ronald D. (Editor)
2005-01-01
As technological advances influence the efficiency and effectiveness of aerodynamic and hydrodynamic applications, designs and operations, this workshop was intended to address the technologies, systems, challenges and successes specific to Coanda driven circulation control in aerodynamics and hydrodynamics. A major goal of this workshop was to determine the 2004 state-of-the-art in circulation control and understand the roadblocks to its application. The workshop addressed applications, CFD, and experiments related to circulation control, emphasizing fundamental physics, systems analysis, and applied research. The workshop consisted of 34 single session oral presentations and written papers that focused on Naval hydrodynamic vehicles (e.g. submarines), Fixed Wing Aviation, V/STOL platforms, propulsion systems (including wind turbine systems), ground vehicles (automotive and trucks) and miscellaneous applications (e.g., poultry exhaust systems and vacuum systems). Several advanced CFD codes were benchmarked using a two-dimensional NCCR circulation control airfoil. The CFD efforts highlighted inconsistencies in turbulence modeling, separation and performance predictions.
Slip stream apparatus and method for treating water in a circulating water system
Cleveland, J.R.
1997-03-18
An apparatus is described for treating water in a circulating water system that has a cooling water basin which includes a slip stream conduit in flow communication with the circulating water system, a source of acid solution in flow communication with the slip stream conduit, and a decarbonator in flow communication with the slip stream conduit and the cooling water basin. In use, a slip stream of circulating water is drawn from the circulating water system into the slip stream conduit of the apparatus. The slip stream pH is lowered by contact with an acid solution provided from the source thereof. The slip stream is then passed through a decarbonator to form a treated slip stream, and the treated slip stream is returned to the cooling water basin. 4 figs.
Public Library Automation Report: Circulation [and] Appendix.
ERIC Educational Resources Information Center
Gotanda, Masae; And Others
An online circulation system--ULISYS (the Universal Library System Ltd.) manufactured by Digital Equipment Corporation (DEC)--is being installed in the Hawaii State Library, Kaneohe Regional Library, Kailua Community Library and Waimanalo Community/School Library. These libraries are the first users of a statewide online circulation system…
Witnesses' memory for events and faces under elevated levels of intoxication.
Altman, Christopher M; Schreiber Compo, Nadja; McQuiston, Dawn; Hagsand, Angelica V; Cervera, Jiselle
2018-08-01
Research on alcohol and witness memory has burgeoned over the last decade. However, most studies have tested participants at relatively low breath alcohol concentration (BAC) levels, unrepresentative of those encountered by officers in the field. To examine how higher intoxication levels might impair witness memory for events and faces, the current research tested participants' ability to recall a mock crime at elevated BAC levels (>.08%). The BAC levels of bar patrons (N = 138) were recorded before witnessing a video-taped mock crime. Participants were then interviewed using free recall and cued questions and shown a six-person target-present or target-absent lineup. Results show that alcohol negatively affected both the quantity and quality of recall. Regardless of question format, alcohol also reduced the percentage of accurate information elicited from witnesses; however, only cued questions increased the percentage of inaccurate information reported. Intoxication had no effect on identification accuracy. These findings suggest that the encoding and storage systems for faces and events may be impacted differently by alcohol. Our results also highlight the importance of including higher BAC levels when examining the effects of alcohol on witness memory.
McGuirt, Delaney
2016-09-01
To assess alternatives to sedation and general anesthesia to prepare children for magnetic resonance (MR) imaging examinations. Online databases were searched for articles discussing methods of preparing children for MR imaging procedures. Because of the large number of articles returned, criteria were limited to only studies that prepared patients without the use of sedation or general anesthesia. Twenty-four studies were deemed appropriate for inclusion in the review. The following methods emerged as alternatives to pediatric sedation: mock scanners, MR-compatible audiovisual systems, feed-sleep manipulation, play therapy, infant incubators/immobilizers, photo diaries, sucrose solutions, and guided imagery. The approaches with the most extensive research were mock MR scanners and feed-sleep manipulation. Evidence supports the use of these alternative techniques as valid substitutes for pediatric sedation and general anesthesia. To reduce the risks associated with sedation of pediatric patients, institutions could implement the alternatives discussed in this review. Cost analyses should be conducted first because some methods are more expensive than others. Finally, further research is needed to better assess the effectiveness of lesser-practiced methods, including photo diaries, sucrose solutions, and guided imagery. ©2016 American Society of Radiologic Technologists.
NASA Astrophysics Data System (ADS)
Tsuru, Daigo; Tanigawa, Hisashi; Hirose, Takanori; Mohri, Kensuke; Seki, Yohji; Enoeda, Mikio; Ezato, Koichiro; Suzuki, Satoshi; Nishi, Hiroshi; Akiba, Masato
2009-06-01
As the primary candidate of ITER Test Blanket Module (TBM) to be tested under the leadership of Japan, a water cooled solid breeder (WCSB) TBM is being developed. This paper shows the recent achievements towards the milestones of ITER TBMs prior to the installation, which consist of design integration in ITER, module qualification and safety assessment. With respect to the design integration, targeting the detailed design final report in 2012, structure designs of the WCSB TBM and the interfacing components (common frame and backside shielding) that are placed in a test port of ITER and the layout of the cooling system are presented. As for the module qualification, a real-scale first wall mock-up fabricated by using the hot isostatic pressing method by structural material of reduced activation martensitic ferritic steel, F82H, and flow and irradiation test of the mock-up are presented. As for safety milestones, the contents of the preliminary safety report in 2008 consisting of source term identification, failure mode and effect analysis (FMEA) and identification of postulated initiating events (PIEs) and safety analyses are presented.
BAO from Angular Clustering: Optimization and Mitigation of Theoretical Systematics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crocce, M.; et al.
We study the theoretical systematics and optimize the methodology in Baryon Acoustic Oscillations (BAO) detections using the angular correlation function with tomographic bins. We calibrate and optimize the pipeline for the Dark Energy Survey Year 1 dataset using 1800 mocks. We compare the BAO fitting results obtained with three estimators: the Maximum Likelihood Estimator (MLE), Profile Likelihood, and Markov Chain Monte Carlo. The MLE method yields the least bias in the fit results (bias/spreadmore » $$\\sim 0.02$$) and the error bar derived is the closest to the Gaussian results (1% from 68% Gaussian expectation). When there is mismatch between the template and the data either due to incorrect fiducial cosmology or photo-$z$ error, the MLE again gives the least-biased results. The BAO angular shift that is estimated based on the sound horizon and the angular diameter distance agree with the numerical fit. Various analysis choices are further tested: the number of redshift bins, cross-correlations, and angular binning. We propose two methods to correct the mock covariance when the final sample properties are slightly different from those used to create the mock. We show that the sample changes can be accommodated with the help of the Gaussian covariance matrix or more effectively using the eigenmode expansion of the mock covariance. The eigenmode expansion is significantly less susceptible to statistical fluctuations relative to the direct measurements of the covariance matrix because the number of free parameters is substantially reduced [$p$ parameters versus $p(p+1)/2$ from direct measurement].« less
Introduction of OX40 ligand into lymphoma cells elicits anti-lymphoma immunity in vivo.
Kaneko, Hitomi; Hori, Toshiyuki; Yanagita, Soshi; Kadowaki, Norimitsu; Uchiyama, Takashi
2005-03-01
OX40, a member of the TNF receptor superfamily, and its ligand (OX40L) play crucial roles in induction and maintenance of integrated T cell immune response. Engagement of OX40L delivers a costimulatory signal to T cells. In this study, we investigated whether inoculation of OX40L-transfected EL4, a murine T cell lymphoma cell line, could induce anti-lymphoma immunity in mice. Female C57BL/6 mice were inoculated with 1 x 10(5) cells of parental EL4, OX40L-transfected EL4 (EL4-OX40L), or mock control vector-transfected EL4 (EL4-mock), and then the tumor size, overall survival, CTL activity of spleen cells, and the immunohistochemistry were compared. While both parental EL4 and EL4-mock grew rapidly, EL4-OX40L was rejected or grew slower than parental EL4 or EL4-mock. Pretreatment of mice with either anti-CD4 or anti-CD8 mAb accelerated the growth of EL4-OX40L, suggesting that both CD4+ and CD8+ T cells were involved in anti-lymphoma immunity. The immunohistochemical study revealed the infiltration of CD8+ T cells into the tumor of EL4-OX40L. In vitro CTL assay demonstrated that spleen cells of mice that had rejected EL4-OX40L had significant cytotoxic activity against parental EL4. The gene transfer of OX40L into lymphoma cells is an eligible and efficient modality to induce anti-lymphoma immunity.
Empirical justification of the elementary model of money circulation
NASA Astrophysics Data System (ADS)
Schinckus, Christophe; Altukhov, Yurii A.; Pokrovskii, Vladimir N.
2018-03-01
This paper proposes an elementary model describing the money circulation for a system, composed by a production system, the government, a central bank, commercial banks and their customers. A set of equations for the system determines the main features of interaction between the production and the money circulation. It is shown, that the money system can evolve independently of the evolution of production. The model can be applied to any national economy but we will illustrate our claim in the context of the Russian monetary system.
1984-09-01
information when making a decision [ Szilagyi and Wallace , 1983:3201." Driver and Mock used cognitive complexity ideas to develop this two dimensional...flexible AMOUNT OF INFORMATION USED High hierarchic integrative Figure 6. Cognitive Complexity Model ( Szilagyi and Wallace , 1983:321) Decisive Style. The...large amount of inform- ation. However, he processes this information with a multiple focus approach ( Szilagyi and Wallace , 1983:320-321). 26 McKenney
2013-09-11
CAPE CANAVERAL, Fla. – A remote-controlled aircraft flies during a competition with a unique set of sensors and software to conduct a mock search-and-rescue operation. The aircraft was assembled by a team of engineers from NASA's Kennedy Space Center. Teams from Johnson Space Center, Kennedy and Marshall Space Flight Center competed in the unmanned aerial systems event to evaluate designs and work by engineers learning new specialties. The competition took place at the Shuttle Landing Facility at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
2013-09-11
CAPE CANAVERAL, Fla. – A remote-controlled aircraft flies during a competition with a unique set of sensors and software to conduct a mock search-and-rescue operation. The aircraft was assembled by a team of engineers from NASA's Kennedy Space Center. Teams from Johnson Space Center, Kennedy and Marshall Space Flight Center competed in the unmanned aerial systems event to evaluate designs and work by engineers learning new specialties. The competition took place at the Shuttle Landing Facility at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
2013-09-11
CAPE CANAVERAL, Fla. – A remote-controlled aircraft flies during a competition with a unique set of sensors and software to conduct a mock search-and-rescue operation. The aircraft was assembled by a team of engineers from NASA's Marshall Space Flight Center. Teams from Johnson Space Center, Kennedy Space Center and Marshall competed in the unmanned aerial systems event to evaluate designs and work by engineers learning new specialties. The competition took place at the Shuttle Landing Facility at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
2013-09-11
CAPE CANAVERAL, Fla. – A remote-controlled aircraft takes off during a competition with a unique set of sensors and software to conduct a mock search-and-rescue operation. The aircraft was assembled by a team of engineers from NASA's Kennedy Space Center. Teams from Johnson Space Center, Kennedy and Marshall Space Flight Center competed in the unmanned aerial systems event to evaluate designs and work by engineers learning new specialties. The competition took place at the Shuttle Landing Facility at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
2013-09-11
CAPE CANAVERAL, Fla. – A remote-controlled aircraft flies during a competition with a unique set of sensors and software to conduct a mock search-and-rescue operation. The aircraft was assembled by a team of engineers from NASA's Kennedy Space Center. Teams from Johnson Space Center, Kennedy and Marshall Space Flight Center competed in the unmanned aerial systems event to evaluate designs and work by engineers learning new specialties. The competition took place at the Shuttle Landing Facility at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
Formative assessment in mathematics for engineering students
NASA Astrophysics Data System (ADS)
Ní Fhloinn, Eabhnat; Carr, Michael
2017-07-01
In this paper, we present a range of formative assessment types for engineering mathematics, including in-class exercises, homework, mock examination questions, table quizzes, presentations, critical analyses of statistical papers, peer-to-peer teaching, online assessments and electronic voting systems. We provide practical tips for the implementation of such assessments, with a particular focus on time or resource constraints and large class sizes, as well as effective methods of feedback. In addition, we consider the benefits of such formative assessments for students and staff.
STS-134 crew during EVA TPS Overview training in the TPS/PABF
2009-12-15
JSC2009-E-284897 (15 Dec. 2009) --- STS-134 crew members participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA?s Johnson Space Center. Pictured from the right are NASA astronauts Andrew Feustel, Greg Chamitoff, Michael Fincke, all mission specialists; along with NASA astronaut Gregory H. Johnson, pilot; and European Space Agency astronaut Roberto Vittori, mission specialist. John Ray (left) assisted the crew members.
Validation of Alternative to Ozone-Depleting Chemicals Used in Oxygen Line Cleaning
2006-07-01
concentration in air purge stream is continuously below 600 ppm ASTM G88 Leak testing B-1B mock-up and actual 2.9 To be determined from system...to determine the effectiveness of the solvent: the solvent chosen, its concentration , and the shear stress exerted on the surface by the cleaning...operators must be trained in its use. 11 3.0 DEMONSTRATION DESIGN 3.1 PERFORMANCE OBJECTIVES The objective for this project was to produce a
Flat Tile Armour Cooled by Hypervapotron Tube: a Possible Technology for ITER
NASA Astrophysics Data System (ADS)
Schlosser, J.; Escourbiac, F.; Merola, M.; Schedler, B.; Bayetti, P.; Missirlian, M.; Mitteau, R.; Robin-Vastra, I.
Carbon fibre composite (CFC) flat tile armours for actively cooled plasma facing components (PFC’s) are an important challenge for controlled fusion machines. Flat tile concepts, water cooled by tubes, were studied, developed, tested and finally operated with success in Tore Supra. The components were designed for 10 MW/m2 and mock-ups were successfully fatigue tested at 15 MW/m2, 1000 cycles. For ITER, a tube-in-tile concept was developed and mock-ups sustained up to 25 MW/m2 for 1000 cycles without failure. Recently flat tile armoured mock-ups cooled by a hypervapotron tube successfully sustained a cascade failure test under a mean heat flux of 10 MW/m2 but with a doubling of the heat flux on some tiles to simulate missing tiles (500 cycles). This encouraging results lead to reconsider the limits for flat tile concept when cooled by hypervapotron (HV) tube. New tests are now scheduled to investigate these limits in regard to the ITER requirements. Experimental evidence of the concept could be gained in Tore Supra by installing a new limiter into the machine.
Golding, Jonathan M; Fryman, Heather M; Marsil, Dorothy F; Yozwiak, John A
2003-11-01
This study investigated the effect of child witness demeanor (defined as crying) on mock jurors' decisions in a simulated First-Degree rape trial. One hundred and thirty-three undergraduates serving in the role of mock jurors read a trial summary in which the primary independent variable was the demeanor of the alleged child victim (i.e., calm, teary, hysterical crying). In addition to reading the summary, participants viewed pencil drawings of the witnesses that were presented as "courtroom drawings." The results showed that the teary condition led to more guilty verdicts and a greater belief in the alleged victim than the other demeanor conditions. Findings from this study indicate that demeanor can impact the perception of a child who is an alleged sexual assault victim in court. However, it is not simply the case that any display of demeanor will lead to a positive outcome for the alleged victim. Instead, it appears that too little or too much emotion from the alleged child victim negatively affected credibility in the eyes of the mock jurors.
NASA Astrophysics Data System (ADS)
Valluri, Monica; Vasiliev, Eugene; Bentz, Misty; Shen, Juntai
2018-04-01
Although 60% of disk galaxies are barred, stellar dynamical measurements of the masses of supermassive black holes (SMBH) in barred galaxies have always been obtained under the assumption that the bulges are axisymmetric. We use N-body simulations with self-consistently grown SMBHs in barred and unbarred galaxies to create a suite of mock Integral Field Spectrographic (IFS) datasets for galaxies with various observed orientations. We then apply an axisymmetric orbit superposition code to these mock IFS datasets to assess the reliability with which SMBH masses can be recovered. We also assess which disk and bar orientations give rise to biases. We use these simulations to assess whether or not existing SMBH measurements in barred galaxies are likely to be biased. We also present a brief preview of our JWST Early Release Science proposal to study the nuclear dynamics of nearby Seyfert I galaxy NGC 4151 with the NIRSpec Integral Field Spectrograph and describe how simulations of disk galaxies will used to create mock NIRSpec data to prepare for the real data.
Aerospace industry representatives view actual and mock-up versions of 'X-Planes' intended to enhanc
NASA Technical Reports Server (NTRS)
2000-01-01
Aerospace industry representatives view actual and mock-up versions of 'X-Planes' intended to enhance access to space during a technical exposition on June 22, 2000 at Dryden Flight Research Center, Edwards, California. From left to right: NASA's B-52 launch aircraft, in service with NASA since 1959; a neutral-buoyancy model of the Boeing's X-37; the Boeing X-40A behind the MicroCraft X-43 mock-up; Orbital Science's X-34 and the modified Lockheed L-1011 airliner that was to launch the X-34. These X-vehicles are part of NASA's Access to Space plan intended to bring new technologies to bear in an effort to dramatically lower the cost of putting payloads in space, and near-space environments. The June 22, 2000 NASA Reusable Launch Vehicle (RLV) Technology Exposition included presentations on the history, present, and future of NASA's RLV program. Special Sessions for industry representatives highlighted the X-37 project and its related technologies. The X-37 project is managed by NASA's Marshall Space Flight Center, Huntsville, Alabama.
At NASA Dryden, Aerospace industry representatives view actual and mock-up versions of 'X-Planes' in
NASA Technical Reports Server (NTRS)
2000-01-01
Aerospace industry representatives view actual and mock-up versions of 'X-Planes' intended to enhance access to space during a technical exposition on June 22, 2000 at Dryden Flight Research Center, Edwards, California. From left to right: NASA's B-52 launch aircraft, in service with NASA since 1959; a neutral-buoyancy model of the Boeing's X-37; the Boeing X-40A behind the MicroCraft X-43 mock-up; Orbital Science's X-34 and the modified Lockheed L-1011 airliner that was to launch the X-34. These X-vehicles are part of NASA's Access to Space plan intended to bring new technologies to bear in an effort to dramatically lower the cost of putting payloads in space, and near-space environments. The June 22, 2000 NASA Reusable Launch Vehicle (RLV) Technology Exposition included presentations on the history, present, and future of NASA's RLV program. Special Sessions for industry representatives highlighted the X-37 project and its related technologies. The X-37 project is managed by NASA's Marshall Space Flight Center, Huntsville, Alabama.
A collaborative approach to residency preparation programming for pharmacy students.
Rider, Shyla K; Oeder, Jessica L; Nguyen, Trang T; Rodis, Jennifer L
2014-06-01
An innovative program to help pharmacy students navigate the residency application and interview process is described, including results of a survey evaluating the program's impact. The Ohio State University (OSU) chapter of the Student Society of Health-System Pharmacy (SSHP) collaborated with OSU College of Pharmacy faculty members, pharmacists from OSU Wexner Medical Center and surrounding areas, and current pharmacy residents to provide programming to equip pharmacy students with skills to succeed as residency candidates. The programming has four components: Curriculum Vitae (CV) Critique, Mock Residency Interviews, Residency 101, and Midyear to Match (M-M), a six-part series that provides guidance on the Residency Showcase at the American Society of Health-System Pharmacists (ASHP) Midyear Clinical Meeting, Match day (the annual matching process coordinated by ASHP), and the post-Match "scramble," in which unmatched applicants compete for unfilled residency slots. In an online survey conducted by the SSHP chapter after the 2012-13 residency year, 26 of 57 survey respondents indicated they had pursued a residency. Twenty respondents reported success in the Match (a rate 15% higher than the national average), with 9 reporting acceptance by their first-choice residency site. The mock interview program was rated as the most useful (a mean score of 4.8 on a 5-point scale), followed by the M-M series (mean score, 4.6). Collaborative programming coordinated by the OSU chapter of SSHP was offered to pharmacy students to improve preparation for the residency application and interview process. The program was well received by participants. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Development of crawler type device using new measuring system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maruyama, T.; Sasaki, T.; Yagi, T.
1995-08-01
This paper reports the development and field application of a new device which examine shell to shell weld joints of RPV. In a BWR type nuclear power plant, there is narrow space around the Reactor Pressure Vessel (RPV) because RPV is enclosed by the Reactor Shield Wall (RSW) and thermal insulations. The developed device is characterized by a new position measuring system and magnet wheels for driving. The new position measuring system uses laser beam and ultrasonic wave. The magnet wheels make the device travel freely in the narrow space between RPV and insulation. This device is tested on mock-upsmore » and applied examination of RPVs to verify field applicability.« less
Slip stream apparatus and method for treating water in a circulating water system
Cleveland, Joe R.
1997-01-01
An apparatus (10) for treating water in a circulating water system (12) t has a cooling water basin (14) includes a slip stream conduit (16) in flow communication with the circulating water system (12), a source (36) of acid solution in flow communication with the slip stream conduit (16), and a decarbonator (58) in flow communication with the slip stream conduit (16) and the cooling water basin (14). In use, a slip stream of circulating water is drawn from the circulating water system (12) into the slip stream conduit (16) of the apparatus (10). The slip stream pH is lowered by contact with an acid solution provided from the source (36) thereof. The slip stream is then passed through a decarbonator (58) to form a treated slip stream, and the treated slip stream is returned to the cooling water basin (14).
Model Predictions and Observed Performance of JWST's Cryogenic Position Metrology System
NASA Technical Reports Server (NTRS)
Lunt, Sharon R.; Rhodes, David; DiAntonio, Andrew; Boland, John; Wells, Conrad; Gigliotti, Trevis; Johanning, Gary
2016-01-01
The James Webb Space Telescope cryogenic testing requires measurement systems that both obtain a very high degree of accuracy and can function in that environment. Close-range photogrammetry was identified as meeting those criteria. Testing the capability of a close-range photogrammetric system prior to its existence is a challenging problem. Computer simulation was chosen over building a scaled mock-up to allow for increased flexibility in testing various configurations. Extensive validation work was done to ensure that the actual as-built system meet accuracy and repeatability requirements. The simulated image data predicted the uncertainty in measurement to be within specification and this prediction was borne out experimentally. Uncertainty at all levels was verified experimentally to be less than 0.1 millimeters.
CONSTELLATION Images from other centers - February 2010
2010-02-08
JSC2010-E-019461 (8 Feb. 2010) --- STS-131 crew members participate in a training session in an International Space Station mock-up/trainer in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Pictured from the left (foreground) are NASA astronaut Stephanie Wilson, Japan Aerospace Exploration Agency (JAXA) astronaut Naoko Yamazaki and NASA astronaut Clayton Anderson, all mission specialists. Pictured from the left (background) are NASA astronauts Alan Poindexter, commander; along with Dorothy Metcalf-Lindenburger and Rick Mastracchio, both mission specialists. Instructor Jeremy Owen (right foreground) assisted the crew members. Not pictured is NASA astronaut James P. Dutton Jr., pilot.
Neutron spectrum from the little boy mock-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robba, A.A.
1986-01-01
Most of the human exposure data used for setting radiation protection guidelines have been obtained by following the survivors of the nuclear explosions at Hiroshima and Nagasaki. Proper evaluation of these data requires estimates of the radiation exposure received by those survivors. Until now neutron dose estimates have relied primarily on calculations as no measurements of the leakage neutron flux or neutron spectrum were available. We have measured the high-energy leakage neutron spectrum from a mock-up of the Little Boy device operating at delayed critical. The measurements are compared with Monte Carlo calculations of the leakage neutron spectrum.
Bilateral Complete and Incomplete Fusion of Incisors and its Management.
Da Costa, Godwin Clovis; Chalakkal, Paul; De Souza, Neil; Gavhane, Sanket
2017-01-01
This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.
Kolyva, Christina; Pepper, John R; Khir, Ashraf W
2016-08-01
The major hemodynamic benefits of intra-aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (Paug ) during inflation, and decrease in end-diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher Paug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice of IAB shape that prioritizes the recovery of those hemodynamic indices that are more in need of support in the unassisted circulation. © 2016 The Authors Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for Artificial Organ and Transplantation (ICAOT).
Kolyva, Christina; Pepper, John R.
2016-01-01
Abstract The major hemodynamic benefits of intra‐aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (P aug) during inflation, and decrease in end‐diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher P aug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice of IAB shape that prioritizes the recovery of those hemodynamic indices that are more in need of support in the unassisted circulation. PMID:27530674
An artificial right ventricle for failing fontan: in vitro and computational study.
Lacour-Gayet, François G; Lanning, Craig J; Stoica, Serban; Wang, Rui; Rech, Bryan A; Goldberg, Steven; Shandas, Robin
2009-07-01
The aim of this study is to develop a destination low-pressure artificial right ventricle (ARV) to correct the impaired hemodynamics in the failing Fontan circulation. An in vitro model circuit of the Fontan circulation was created to reproduce the hemodynamics of the failing Fontan and test ARV performance under various central venous pressures (CVP) and flows. A novel geometry of the extracardiac conduit was designed to adapt to the need of the pump. The ARV was a low-pressure axial flow pump designed to produce a low suction inflow pressure and moderate outflow increase. With the power off, the passive forward gradient across the propeller is 2 mm Hg at 4.5 L/min. The ARV would require 4 watts at a rotation of 5000 rpm. To examine the shear loading on the red blood cells, virtual particles were injected upstream of the ARV inducer and tracked by computerized modeling. The effect of the ARV on the failing Fontan was studied at various CVP pressures and flows, and under constant values of lung resistances and left atrial pressure set respectively to 2.5 Woods Units and 7 mm Hg. The CVP pressures decreased respectively from 25, 22.5, 20, 17.5, 15, and 10 mm Hg to a minimal value of 2 to 5 mm Hg with a pump speed varying from 1700 to 4500 rpm. The pulmonary artery pressures increased moderately between 12.5 and 25 mm Hg at 4500 rpm. Cardiac output at 4500 rpm was increased by an average gain of 2 L/min. The average blood damage index was 0.92%, far below the 5% value considered to cause hemolysis. The flow structure produced by the pump was suitable. The performance of this novel low-pressure ARV was satisfactory, showing good decrease of CVP pressures, a moderate increase of pulmonary artery pressures, adequate increase of cardiac output, and minimal hemolysis. The use of a mock Fontan model circuit facilitates device prototyping and design to a far greater extent than can be achieved using animal studies, and is an essential first step for rapid design iteration of a novel ARV device. The next steps are the manufacturing of this device, including an electromagnetic engine, a regulatory system, and further testing the device in a survival animal experiment.
Mariner, R.H.; Evans, William C.; Young, H.W.
2006-01-01
Circulation times of waters in geothermal systems are poorly known. In this study, we examine the thermal waters of the Idaho batholith to verify whether maximum system temperatures, helium concentrations, and 14C values are related to water age in these low-to-moderate temperature geothermal systems. He/N2 values of gas collected from thermal waters that circulate solely through distinct units of the Idaho batholith correlate linearly with Na-K-(4/3)Ca geothermometer temperatures, showing that both variables are excellent indicators of relative water age. Thermal waters that circulate in early Tertiary (45-50 Ma) granite of the Sawtooth batholith have 3.5 times more helium than thermal waters of the same aquifer temperature that circulate through the main Cretaceous granite (average 91 Ma). Hot spring waters circulating in hydrothermally altered parts of the batholith have very little dissolved helium and no correlation between He/N2 values and geothermometer temperatures. Thermal waters discharging from the Idaho batholith are more depleted in deuterium than modern precipitation in the area. Recharge to these geothermal systems occurred from at least 10,000 BP for the cooler systems up to about 33,000 BP for the hotter systems.
Sieber, Sandro; Grossen, Philip; Detampel, Pascal; Siegfried, Salome; Witzigmann, Dominik; Huwyler, Jörg
2017-10-28
Nanomedicines have gained much attention for the delivery of small molecules or nucleic acids as treatment options for many diseases. However, the transfer from experimental systems to in vivo applications remains a challenge since it is difficult to assess their circulation behavior in the body at an early stage of drug discovery. Thus, innovative and improved concepts are urgently needed to overcome this issue and to close the gap between empiric nanoparticle design, in vitro assessment, and first in vivo experiments using rodent animal models. This study was focused on the zebrafish as a vertebrate screening model to assess the circulation in blood and extravasation behavior of nanoparticulate drug delivery systems in vivo. To validate this novel approach, monodisperse preparations of fluorescently labeled liposomes with similar size and zeta potential were injected into transgenic zebrafish lines expressing green fluorescent protein in their vasculature. Phosphatidylcholine-based lipids differed by fatty acid chain length and saturation. Circulation behavior and vascular distribution pattern were evaluated qualitatively and semi-quantitatively using image analysis. Liposomes composed of lipids with lower transition temperature (<28°C) as well as PEGylated liposomes showed longer circulation times and extravasation. In contrast, liposomes composed of lipids with transition temperatures>28°C bound to venous parts of the vasculature. This circulation patterns in the zebrafish model did correlate with published and experimental pharmacokinetic data from mice and rats. Our findings indicate that the zebrafish model is a useful vertebrate screening tool for nanoparticulate drug delivery systems to predict their in vivo circulation behavior with respect to systemic circulation time and exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
An elementary model of money circulation
NASA Astrophysics Data System (ADS)
Pokrovskii, Vladimir N.; Schinckus, Christophe
2016-12-01
This paper investigates money circulation for a system, consisting of a production system, the government, a central bank, commercial banks and many customers of the commercial banks. A set of equations for the system is written; the theory determines the main features of interaction between production and money circulation. Investigation of the equations in a steady-state situation reveals some relationship among output of the production system and monetary variables. The relation of quantity theory of money is confirmed, whereas a new concept of the efficiency of the system is introduced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, S; Zhang, J; Hadsell, M
Purpose: Microbeam radiation therapy and GRID therapy are different forms of Spatially-Fractioned Radiation Therapy (SFRT) that is fundamentally different from the conventional seamless and temporally fractionated radiation therapy. SFRT is characterized by a ultra-high dose (10s –100s Gy) dose single treatment with drastic inhomogeneity pattern of given spatial frequencies. Preclinical and limited clinical studies have shown that the SFRT treatments may offer significant improvements in reducing treatment toxicity, especially for those patients who have not benefited from the state-of-the-art radiation therapy approaches. This preliminary study aims to elucidate the underlying working mechanisms of SFRT, which currently remains poorly understood. Methods:more » A genetically engineered 4T1 murine mammary carcinoma cell line and nude mice skin fold window chamber were used. A nanotechnology-based 160kV x-ray irradiator delivered 50Gy (entrance dose) single treatments of microbeam or seamless radiation. Animals were in 3 groups: mock, seamless radiation, and 300μm microbeam radiation. The windows were imaged using a hyperspectral system to capture total hemoglobin/saturation, GFP fluorescence emission, RFP fluorescence emission, and vessel density at 9 time points up to 7 days post radiation. Results: We found unique physiologic changes in different tumor/normal tissue regions and differential effects between seamless and microbeam treatments. They include 1) compared to microbeam and mock radiation seamless radiation damaged more microvasculature in tumor-surrounding normal tissue, 2) a pronounced angiogenic effect was observed with vascular proliferation in the microbeam irradiated portion of the tumor days post treatment (no such effect observed in seamless and mock groups), and 3) a notable change in tumor vascular orientation was observed where vessels initially oriented parallel to the beam length were replaced by vessels running perpendicular to the irradiation portion of the tumor. Conclusion: Our preliminary study indicated that microbeam radiation modified tumor microenvironment in ways significantly different than of the conventional seamless radiation.« less
Park, Jae Hyun; Putrus, Raphael R; Pruzansky, Dawn P; Grubb, John
2017-03-01
The objective of this study was to identify the board certification protocols that hospital and university-based postgraduate orthodontic programs have in place to prepare residents for the American Board of Orthodontics (ABO) certification examination. An electronic survey was sent to the program directors of each of the 72 postgraduate orthodontic programs in the United States and Canada. The survey consisted of 49 questions about demographics, resident case assignment protocols, and ABO examination preparation methods. The response rate was 81%. Most programs were 30 to 36 months in length (72.7%). Many residents had a case load of 51 to 75 during their first year (50.9%), with an average maximum case load of 70 to 109. There was a positive correlation with both the number of cases that first-year residents start and the length of the program (Spearman correlation coefficient = 0.379; P <0.01) when compared with maximum case load. Approximately 72% of the programs do not offer a written mock board examination; however, 72% reported offering a clinical mock board examination. ABO cases are identified within the first 6 months of most programs. About 88% of respondents believe that residents take advantage of the banking system, and that over the past 5 years ABO Initial Certification Examination applications have increased. Most program directors (89.1%) believe that their program length is sufficient for board preparation. Subjects tested in the written examination are integrated into the didactic curriculum and strengthened with ongoing literature reviews, with a passing rate over 90%. Clinical examination preparation varies, with most programs requiring a mock board examination for graduation. Total participation in both the Initial Certification Examination and banking has increased since 2010; better follow-up protocols are needed to track residents after graduation. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kazin, Eyal A.; Blanton, Michael R.; Scoccimarro, Roman
2010-08-20
We analyze the line-of-sight baryonic acoustic feature in the two-point correlation function {xi} of the Sloan Digital Sky Survey luminous red galaxy (LRG) sample (0.16 < z < 0.47). By defining a narrow line-of-sight region, r{sub p} < 5.5 h {sup -1} Mpc, where r{sub p} is the transverse separation component, we measure a strong excess of clustering at {approx}110 h {sup -1} Mpc, as previously reported in the literature. We also test these results in an alternative coordinate system, by defining the line of sight as {theta} < 3{sup 0}, where {theta} is the opening angle. This clustering excessmore » appears much stronger than the feature in the better-measured monopole. A fiducial {Lambda}CDM nonlinear model in redshift space predicts a much weaker signature. We use realistic mock catalogs to model the expected signal and noise. We find that the line-of-sight measurements can be explained well by our mocks as well as by a featureless {xi} = 0. We conclude that there is no convincing evidence that the strong clustering measurement is the line-of-sight baryonic acoustic feature. We also evaluate how detectable such a signal would be in the upcoming Baryon Oscillation Spectroscopic Survey (BOSS) LRG volume. Mock LRG catalogs (z < 0.6) suggest that (1) the narrow line-of-sight cylinder and cone defined above probably will not reveal a detectable acoustic feature in BOSS; (2) a clustering measurement as high as that in the current sample can be ruled out (or confirmed) at a high confidence level using a BOSS-sized data set; (3) an analysis with wider angular cuts, which provide better signal-to-noise ratios, can nevertheless be used to compare line-of-sight and transverse distances, and thereby constrain the expansion rate H(z) and diameter distance D{sub A}(z).« less
To track or not to track: user reactions to concepts in longitudinal health monitoring.
Beaudin, Jennifer S; Intille, Stephen S; Morris, Margaret E
2006-01-01
Advances in ubiquitous computing, smart homes, and sensor technologies enable novel, longitudinal health monitoring applications in the home. Many home monitoring technologies have been proposed to detect health crises, support aging-in-place, and improve medical care. Health professionals and potential end users in the lay public, however, sometimes question whether home health monitoring is justified given the cost and potential invasion of privacy. The aim of the study was to elicit specific feedback from health professionals and laypeople about how they might use longitudinal health monitoring data for proactive health and well-being. Interviews were conducted with 8 health professionals and 26 laypeople. Participants were asked to evaluate mock data visualization displays that could be generated by novel home monitoring systems. The mock displays were used to elicit reactions to longitudinal monitoring in the home setting as well as what behaviors, events, and physiological indicators people were interested in tracking. Based on the qualitative data provided by the interviews, lists of benefits of and concerns about health tracking from the perspectives of the practitioners and laypeople were compiled. Variables of particular interest to the interviewees, as well as their specific ideas for applications of collected data, were documented. Based upon these interviews, we recommend that ubiquitous "monitoring" systems may be more readily adopted if they are developed as tools for personalized, longitudinal self-investigation that help end users learn about the conditions and variables that impact their social, cognitive, and physical health.
Early Impacts of a Human-in-the-Loop Evaluation in a Space Vehicle Mock-up Facility
NASA Technical Reports Server (NTRS)
Byrne, Vicky; Vos, Gordon; Whitmore, Mihriban
2008-01-01
The development of a new space vehicle, the Orion Crew Exploration Vehicle (CEV), provides Human Factors engineers an excellent opportunity to have an impact early in the design process. This case study highlights a Human-in-the-Loop (HITL) evaluation conducted in a Space Vehicle Mock-Up Facility and will describe the human-centered approach and how the findings are impacting design and operational concepts early in space vehicle design. The focus of this HITL evaluation centered on the activities that astronaut crewmembers would be expected to perform within the functional internal volume of the Crew Module (CM) of the space vehicle. The primary objective was to determine if there are aspects of a baseline vehicle configuration that would limit or prevent the performance of dynamically volume-driving activities (e.g. six crewmembers donning their suits in an evacuation scenario). A second objective was to step through concepts of operations for known systems and evaluate them in integrated scenarios. The functional volume for crewmember activities is closely tied to every aspect of system design (e.g. avionics, safety, stowage, seats, suits, and structural support placement). As this evaluation took place before the Preliminary Design Review of the space vehicle with some designs very early in the development, it was not meant to determine definitely that the crewmembers could complete every activity, but rather to provide inputs that could improve developing designs and concepts of operations definition refinement.
Drosophila increase exploration after visually detecting predators.
de la Flor, Miguel; Chen, Lijian; Manson-Bishop, Claire; Chu, Tzu-Chun; Zamora, Kathya; Robbins, Danielle; Gunaratne, Gemunu; Roman, Gregg
2017-01-01
Novel stimuli elicit behaviors that are collectively known as specific exploration. These behaviors allow the animal to become more familiar with the novel objects within its environment. Specific exploration is frequently suppressed by defensive reactions to predator cues. Herein, we examine if this suppression occurs in Drosophila melanogaster by measuring the response of these flies to wild harvested predators. The flies used in our experiments have been cultured and had not lived under predator threat for multiple decades. In a circular arena with centrally-caged predators, wild type Drosophila actively avoided the pantropical jumping spider, Plexippus paykulli, and the Texas unicorn mantis, Phyllovates chlorophaena, indicating an innate defensive reaction to these predators. Interestingly, wild type Drosophila males also avoided a centrally-caged mock spider, and the avoidance of the mock spider became exaggerated when it was made to move within the cage. Visually impaired Drosophila failed to detect and avoid the Plexippus paykulli and the moving mock spider, while the broadly anosmic orco2 mutants were fully capable of detecting and avoiding Plexippus paykulli, indicating that these flies principally relied upon vison to perceive the predator stimuli. During early exploration of the arena, exploratory activity increased in the presence of Plexippus paykulli and the moving mock spider. The elevated activity induced by Plexippus paykulli disappeared after the fly had finished exploring, suggesting the flies were capable of habituating the predator cues. Taken together, these results indicate that despite being isolated from predators for decades Drosophila will visually detect these predators, retain innate defensive behaviors, respond by increasing exploratory activity in the arena rather than suppressing activity, and may habituate to normal predator cues.
Drosophila increase exploration after visually detecting predators
Manson-Bishop, Claire; Chu, Tzu-Chun; Zamora, Kathya; Robbins, Danielle; Gunaratne, Gemunu
2017-01-01
Novel stimuli elicit behaviors that are collectively known as specific exploration. These behaviors allow the animal to become more familiar with the novel objects within its environment. Specific exploration is frequently suppressed by defensive reactions to predator cues. Herein, we examine if this suppression occurs in Drosophila melanogaster by measuring the response of these flies to wild harvested predators. The flies used in our experiments have been cultured and had not lived under predator threat for multiple decades. In a circular arena with centrally-caged predators, wild type Drosophila actively avoided the pantropical jumping spider, Plexippus paykulli, and the Texas unicorn mantis, Phyllovates chlorophaena, indicating an innate defensive reaction to these predators. Interestingly, wild type Drosophila males also avoided a centrally-caged mock spider, and the avoidance of the mock spider became exaggerated when it was made to move within the cage. Visually impaired Drosophila failed to detect and avoid the Plexippus paykulli and the moving mock spider, while the broadly anosmic orco2 mutants were fully capable of detecting and avoiding Plexippus paykulli, indicating that these flies principally relied upon vison to perceive the predator stimuli. During early exploration of the arena, exploratory activity increased in the presence of Plexippus paykulli and the moving mock spider. The elevated activity induced by Plexippus paykulli disappeared after the fly had finished exploring, suggesting the flies were capable of habituating the predator cues. Taken together, these results indicate that despite being isolated from predators for decades Drosophila will visually detect these predators, retain innate defensive behaviors, respond by increasing exploratory activity in the arena rather than suppressing activity, and may habituate to normal predator cues. PMID:28746346
Systematics in lensing reconstruction: dark matter rings in the sky?
NASA Astrophysics Data System (ADS)
Ponente, P. P.; Diego, J. M.
2011-11-01
Context. Non-parametric lensing methods are a useful way of reconstructing the lensing mass of a cluster without making assumptions about the way the mass is distributed in the cluster. These methods are particularly powerful in the case of galaxy clusters with a large number of constraints. The advantage of not assuming implicitly that the luminous matter follows the dark matter is particularly interesting in those cases where the cluster is in a non-relaxed dynamical state. On the other hand, non-parametric methods have several limitations that should be taken into account carefully. Aims: We explore some of these limitations and focus on their implications for the possible ring of dark matter around the galaxy cluster CL0024+17. Methods: We project three background galaxies through a mock cluster of known radial profile density and obtain a map for the arcs (θ map). We also calculate the shear field associated with the mock cluster across the whole field of view (3.3 arcmin). Combining the positions of the arcs and the two-direction shear, we perform an inversion of the lens equation using two separate methods, the biconjugate gradient, and the quadratic programming (QADP) to reconstruct the convergence map of the mock cluster. Results: We explore the space of the solutions of the convergence map and compare the radial density profiles to the density profile of the mock cluster. When the inversion matrix algorithms are forced to find the exact solution, we encounter systematic effects resembling ring structures, that clearly depart from the original convergence map. Conclusions: Overfitting lensing data with a non-parametric method can produce ring-like structures similar to the alleged one in CL0024.
Planning for Downtown Circulation Systems. Volume 1. Planning Concepts.
DOT National Transportation Integrated Search
1983-10-01
This document brings together the state-of-the-art in planning concepts, methods and data for use by those cities proposing or considering comprehensive or innovative downtown circulation systems, particularly Downtown People Mover systems. DPM syste...
Automated Bilingual Circulation System Using PC Local Area Networks.
ERIC Educational Resources Information Center
Iskanderani, A. I.; Anwar, M. A.
1992-01-01
Describes a personal computer and LAN-based automated circulation system capable of handling both Arabic and Latin characters that was developed for use at King Abdullaziz University (Jeddah, Saudi Arabia). Outlines system requirements, system structure, hardware needs, and individual functional modules of the system. Numerous examples and flow…
Integrating Human Factors into Crew Exploration Vehicle Design
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Baggerman, Susan; Campbell, paul
2007-01-01
With NASA's new Vision for Exploration to send humans beyond Earth orbit, it is critical to consider the human as a system that demands early and continuous user involvement, and an iterative prototype/test/redesign process. Addressing human-system interface issues early on can be very cost effective even cost reducing when performed early in the design and development cycle. To achieve this goal within Crew Exploration Vehicle (CEV) Project Office, human engineering (HE) team is formed. Key tasks are to apply HE requirements and guidelines to hardware/software, and provide HE design, analysis and evaluation of crew interfaces. Initial activities included many practice-orientated evaluations using low-fidelity CEV mock-ups. What follows is a description of such evaluations that focused on a HE requirement regarding Net Habitable Volume (NHV). NHV is defined as the total remaining pressurized volume available to on-orbit crew after accounting for the loss of volume due to deployed hardware and structural inefficiencies which decrease functional volume. The goal of the NHV evaluations was to develop requirements providing sufficient CEV NHV for crewmembers to live and perform tasks in support of mission goals. Efforts included development of a standard NHV calculation method using computer models and physical mockups, and crew/ stakeholder evaluations. Nine stakeholders and ten crewmembers participated in the unsuited evaluations. Six crewmembers also participated in a suited evaluation. The mock-up was outfitted with volumetric representation of sub-systems such as seats, and stowage bags. Thirteen scenarios were developed to represent mission/crew tasks and considered to be primary volume drivers (e.g., suit donning) for the CEV. Unsuited evaluations included a structured walkthrough of these tasks. Suited evaluations included timed donning of the existing launch and entry suit to simulate a contingency scenario followed by doffing/ stowing of the suits. All mockup evaluations were videotaped. Structured questionnaires were used to document user interface issues and volume impacts of layout configuration. Computer model and physical measures of the NHV agreed within 1 percent. This included measurement of the gross habitable volume, subtraction of intrusive volumes, and other non-habitable spaces. Calculation method developed was validated as a standard means of measuring NHV, and was recommended as a verification method for the NHV requirements. Evaluations confirmed that there was adequate volume for unsuited scenarios and suit donning/ doffing activity. Seats, suit design stowage and waste hygiene system noted to be critical volume drivers. The low-fidelity mock-up evaluations along with human modeling analysis generated discussions that will lead to high-level systems requirements and human-centered design decisions. This approach allowed HE requirements and operational concepts to evolve in parallel with engineering system concepts and design requirements. As the CEV design matures, these evaluations will continue and help with design decisions, and assessment, verification and validation of HE requirements.
NASA Astrophysics Data System (ADS)
Marinoni, Christian; Davis, Marc; Newman, Jeffrey A.; Coil, Alison L.
2002-11-01
We have developed a new geometrical method for identifying and reconstructing a homogeneous and highly complete set of galaxy groups within flux-limited redshift surveys. Our method combines information from the three-dimensional Voronoi diagram and its dual, the Delaunay triangulation, to obtain group and cluster catalogs that are remarkably robust over wide ranges in redshift and degree of density enhancement. As free by-products, this Voronoi-Delaunay method (VDM) provides a nonparametric measurement of the galaxy density around each object observed and a quantitative measure of the distribution of cosmological voids in the survey volume. In this paper, we describe the VDM algorithm in detail and test its effectiveness using a family of mock catalogs that simulate the Deep Extragalactic Evolutionary Probe (DEEP2) Redshift Survey, which should present at least as much challenge to cluster reconstruction methods as any other near-future survey that is capable of resolving their velocity dispersions. Using these mock DEEP2 catalogs, we demonstrate that the VDM algorithm can be used to identify a homogeneous set of groups in a magnitude-limited sample throughout the survey redshift window 0.7
Increased numbers of circulating ECs are associated with systemic GVHD.
Yan, Z; Zeng, L; Jia, L; Xu, S; Ding, S
2011-10-01
Circulating endothelial cells (ECs) are known to reflect endothelial injury, and endothelial injury is associated with graft-versus-host disease (GVHD). We hypothesised that circulating ECs might be associated with systemic acute graft-versus-host disease (aGVHD). BALB/c (H-2k(d) ) mice were treated with total body irradiation and then infused with C57B/6-derived T-cell-depleted bone marrow (TCD-BM) cells or TCD-BM cells and splenocytes. Cyclosporine was used to prevent aGVHD. Circulating ECs and allogeneic lymphocytes were analysed by flow cytometry at multiple time points. The morphology and ultrastructure of the endothelium were examined by light microscopy or transmission electron microscopy. The results indicated that the number of circulating ECs peaked at day 5 after lethal irradiation in all mice; allogenic transplanted mice (TCD-BM cells and splenocytes) developed typical aGVHD beginning at day 7, exhibiting both histological and clinical symptoms of disease. Circulating ECs peaked a second time at day 9 with aGVHD progression. However, following the administration of CSA, an absence of or a reduction in the amount of subsequent endothelial injury was observed. Circulating ECs might be associated with systemic aGVHD. © 2011 Blackwell Publishing Ltd.
ERIC Educational Resources Information Center
Frohmberg, Katherine A.; Moffett, William A.
In order to study the effects of introducing an automated circulation system at Oberlin College, Ohio, data were collected from September 1978 until June 1982 on book availability, usage of library facilities, attitudes of library users toward the library, and the efficiency of circulation activities. Data collection methods included circulation…
Systems Analysis, Machineable Circulation Data and Library Users and Non-Users.
ERIC Educational Resources Information Center
Lubans, John, Jr.
A study to be made with computer-based circulation data of the non-use and use of a large academic library is discussed. A search of the literature reveals that computer-based circulation systems can be, but have not been, utilized to provide data bases for systematic analyses of library users and resources. The data gathered in the circulation…
Mechanization in a New Medical School Library II. Serials and Circulation
Payne, Ladye Margarete; Small, Louise; Divett, Robert T.
1966-01-01
The serials and circulation phases of the data-processing system in use at the University of New Mexico Library of the Medical Sciences are described. The development of the programs is also reported. The serials program uses simple punched card equipment. The circulation program uses the IBM 357 Data Collection System and punched card data-processing equipment. Images PMID:5921473
Human factors in command and control for the Los Angeles Fire Department.
Harper, W R
1974-03-01
Ergonomics owes much of its operations and systems heritage to military research. Since public safety systems such as police, fire departments and civil defence organisations are quasi-military in nature, one may reasonably use the findings from military ergonomics research to extrapolate design data for use in a decision-making system. This article discusses a case study concerning Human Factors in command and control for the Los Angeles Fire Department. The case involved transfer from a manual dispatch system involving three geographic areas of metropolitan Los Angeles to one central computer-aided command and control system. Comments are made on console mock-ups, environmental factors in the Control Centre placement of the consoles. Because of extreme delays in procurement of the recommended hardware it is doubtful that empirical testing of the ergonomics aspect of the system will take place.
Schumer, Erin; Höffler, Klaus; Kuehn, Christian; Slaughter, Mark; Haverich, Axel; Wiegmann, Bettina
2018-03-01
The lack of donor organs has led to the development of alternative "destination therapies", such as a bio-artificial lung (BA) for end-stage lung disease. Ultimately aiming at a fully implantable BA, general capabilities and limitations of different oxygenators were tested based on the model of BA positioning at the right upper lobe. Three different-sized oxygenators (neonatal, paediatric, and adult) were tested in a mock circulation loop regarding oxygenation and decarboxylation capacities for three respiratory pathologies. Blood flows were imitated by a roller pump, and respiration was imitated by a mechanical ventilator with different FiO 2 applications. Pressure drops across the oxygenators and the integrity of the gas-exchange hollow fibers were analyzed. The neonatal oxygenator proved to be insufficient regarding oxygenation and decarboxylation. Despite elevated pCO 2 levels, the paediatric and adult oxygenators delivered comparable sufficient oxygen levels, but sufficient decarboxylation across the oxygenators was ensured only at flow rates of 0.5 L min. Only the adult oxygenator indicated no significant pressure drops. For all tested conditions, gas-exchange hollow fibers remained intact. This is the first study showing the general feasibility of delivering sufficient levels of gas exchange to an intracorporeal BA via patient's breathing, without damaging gas-exchange hollow fiber membranes.
Modelling Complex Fenestration Systems using physical and virtual models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanachareonkit, Anothai; Scartezzini, Jean-Louis
2010-04-15
Physical or virtual models are commonly used to visualize the conceptual ideas of architects, lighting designers and researchers; they are also employed to assess the daylighting performance of buildings, particularly in cases where Complex Fenestration Systems (CFS) are considered. Recent studies have however revealed a general tendency of physical models to over-estimate this performance, compared to those of real buildings; these discrepancies can be attributed to several reasons. In order to identify the main error sources, a series of comparisons in-between a real building (a single office room within a test module) and the corresponding physical and virtual models wasmore » undertaken. The physical model was placed in outdoor conditions, which were strictly identical to those of the real building, as well as underneath a scanning sky simulator. The virtual model simulations were carried out by way of the Radiance program using the GenSky function; an alternative evaluation method, named Partial Daylight Factor method (PDF method), was also employed with the physical model together with sky luminance distributions acquired by a digital sky scanner during the monitoring of the real building. The overall daylighting performance of physical and virtual models were assessed and compared. The causes of discrepancies between the daylighting performance of the real building and the models were analysed. The main identified sources of errors are the reproduction of building details, the CFS modelling and the mocking-up of the geometrical and photometrical properties. To study the impact of these errors on daylighting performance assessment, computer simulation models created using the Radiance program were also used to carry out a sensitivity analysis of modelling errors. The study of the models showed that large discrepancies can occur in daylighting performance assessment. In case of improper mocking-up of the glazing for instance, relative divergences of 25-40% can be found in different room locations, suggesting that more light is entering than actually monitored in the real building. All these discrepancies can however be reduced by making an effort to carefully mock up the geometry and photometry of the real building. A synthesis is presented in this article which can be used as guidelines for daylighting designers to avoid or estimate errors during CFS daylighting performance assessment. (author)« less
Carhart-Harris, Robin L; Williams, Tim M; Sessa, Ben; Tyacke, Robin J; Rich, Ann S; Feilding, Amanda; Nutt, David J
2011-11-01
This study sought to assess the tolerability of intravenously administered psilocybin in healthy, hallucinogen-experienced volunteers in a mock-magnetic resonance imaging environment as a preliminary stage to a controlled investigation using functional magnetic resonance imaging to explore the effects of psilocybin on cerebral blood flow and activity. The present pilot study demonstrated that up to 2 mg of psilocybin delivered as a slow intravenous injection produces short-lived but typical drug effects that are psychologically and physiologically well tolerated. With appropriate care, this study supports the viability of functional magnetic resonance imaging work with psilocybin.
The influence of accounts and remorse on mock jurors' judgments of offenders.
Jehle, Alayna; Miller, Monica K; Kemmelmeier, Markus
2009-10-01
Defendants often provide accounts that minimize their responsibility for the accused offense. Jurors attribute responsibility to defendants and decide legal outcomes based on the given account. The current research examined the effects of accounts (i.e., excuse, justification, denial, and no explanation) and the defendant's remorse display (i.e., remorseful, remorseless) on mock jurors' judgments. Participants acquitted the defendant in the denial condition most often and recommended the most lenient punishment in the justification condition. The remorseful defendant was found guilty more frequently than the remorseless defendant in the no explanation and (marginally) excuse conditions. Limitations and future research are discussed.
The Mock LISA Data Challenge Round 3: New and Improved Sources
NASA Technical Reports Server (NTRS)
Baker, John
2008-01-01
The Mock LISA Data Challenges are a program to demonstrate and encourage the development of data-analysis capabilities for LISA. Each round of challenges consists of several data sets containing simulated instrument noise and gravitational waves from sources of undisclosed parameters. Participants are asked to analyze the data sets and report the maximum information they can infer about the source parameters. The challenges are being released in rounds of increasing complexity and realism. Challenge 3. currently in progress, brings new source classes, now including cosmic-string cusps and primordial stochastic backgrounds, and more realistic signal models for supermassive black-hole inspirals and galactic double white dwarf binaries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Revel, G. M.; Castellini, P.; Chiariotti, P.
2010-05-28
The present work deals with the analysis of problems and potentials of laser vibrometer measurements inside helicopter cabins in running conditions. The paper describes the results of a systematic measurement campaign performed on an Agusta A109MKII mock-up. The aim is to evaluate the applicability of Scanning Laser Doppler Vibrometer (SLDV) for tests in simulated flying conditions and to understand how performances of the technique are affected when the laser head is placed inside the cabin, thus being subjected to interfering inputs. Firstly a brief description of the performed test cases and the used measuring set-ups are given. Comparative tests betweenmore » SLDV and accelerometers are presented, analyzing the achievable performances for the specific application. Results obtained measuring with SLDV placed inside the helicopter cabin during operative excitation conditions are compared with those performed with the laser lying outside the mock-up, these last being considered as 'reference measurements'. Finally, in order to give an estimate of the uncertainty level on measured signals, a study linking the admitted percentage of noise content on vibrometer signals due to laser head vibration levels will be introduced.« less
Optimizing Methods of Obtaining Stellar Parameters for the H3 Survey
NASA Astrophysics Data System (ADS)
Ivory, KeShawn; Conroy, Charlie; Cargile, Phillip
2018-01-01
The Stellar Halo at High Resolution with Hectochelle Survey (H3) is in the process of observing and collecting stellar parameters for stars in the Milky Way's halo. With a goal of measuring radial velocities for fainter stars, it is crucial that we have optimal methods of obtaining this and other parameters from the data from these stars.The method currently developed is The Payne, named after Cecilia Payne-Gaposchkin, a code that uses neural networks and Markov Chain Monte Carlo methods to utilize both spectra and photometry to obtain values for stellar parameters. This project was to investigate the benefit of fitting both spectra and spectral energy distributions (SED). Mock spectra using the parameters of the Sun were created and noise was inserted at various signal to noise values. The Payne then fit each mock spectrum with and without a mock SED also generated from solar parameters. The result was that at high signal to noise, the spectrum dominated and the effect of fitting the SED was minimal. But at low signal to noise, the addition of the SED greatly decreased the standard deviation of the data and resulted in more accurate values for temperature and metallicity.
Percolation analysis for cosmic web with discrete points
NASA Astrophysics Data System (ADS)
Zhang, Jiajun; Cheng, Dalong; Chu, Ming-Chung
2016-03-01
Percolation analysis has long been used to quantify the connectivity of the cosmic web. Unlike most of the previous works using density field on grids, we have studied percolation analysis based on discrete points. Using a Friends-of-Friends (FoF) algorithm, we generate the S-bb relation, between the fractional mass of the largest connected group (S) and the FoF linking length (bb). We propose a new model, the Probability Cloud Cluster Expansion Theory (PCCET) to relate the S-bb relation with correlation functions. We show that the S-bb relation reflects a combination of all orders of correlation functions. We have studied the S-bb relation with simulation and find that the S-bb relation is robust against redshift distortion and incompleteness in observation. From the Bolshoi simulation, with Halo Abundance Matching (HAM), we have generated a mock galaxy catalogue. Good matching of the projected two-point correlation function with observation is confirmed. However, comparing the mock catalogue with the latest galaxy catalogue from SDSS DR12, we have found significant differences in their S-bb relations. This indicates that the mock catalogue cannot accurately recover higher order correlation functions than the two-point correlation function, which reveals the limit of HAM method.
Boman, Inga-Lill; Lundberg, Stefan; Starkhammar, Sofia; Nygård, Louise
2014-04-16
Persons with dementia might have considerable difficulties in using an ordinary telephone. Being able to use the telephone can be very important in order to maintain their social network, getting stimulation and for reaching help when needed. Therefore, persons with dementia might need an easy-to-use videophone to prevent social isolation and to feel safe and independent. This study reports the evaluation of the usability of a touch-screen videophone mock-up for persons with dementia and their significant others. Four persons with dementia and their significant others tested the videophone mock-up at a living laboratory. In order to gain knowledge of the participants' with dementia ability to use their own computers and telephones, interviews and observations were conducted. Overall, the participants had a very positive attitude towards the videophone. The participants with dementia perceived that it was useful, enjoyable and easy to use, although they initially had difficulties in understanding how to handle some functions, thus indicating that the design needs to be further developed to be more intuitive. The findings suggest that the videophone has the potential to enable telephone calls without assistance and add quality in communication.
The dark side of galaxy colour
NASA Astrophysics Data System (ADS)
Hearin, Andrew P.; Watson, Douglas F.
2013-10-01
We present age distribution matching, a theoretical formalism for predicting how galaxies of luminosity L and colour C occupy dark matter haloes. Our model supposes that there are just two fundamental properties of a halo that determine the colour and brightness of the galaxy it hosts: the maximum circular velocity Vmax and the redshift zstarve that correlates with the epoch at which the star formation in the galaxy ceases. The halo property zstarve is intended to encompass physical characteristics of halo mass assembly that may deprive the galaxy of its cold gas supply and, ultimately, quench its star formation. The new, defining feature of the model is that, at fixed luminosity, galaxy colour is in monotonic correspondence with zstarve, with the larger values of zstarve being assigned redder colours. We populate an N-body simulation with a mock galaxy catalogue based on age distribution matching and show that the resulting mock galaxy distribution accurately describes a variety of galaxy statistics. Our model suggests that halo and galaxy assembly are indeed correlated. We make publicly available our low-redshift, Sloan Digital Sky Survey Mr < -19 mock galaxy catalogue, and main progenitor histories of all z = 0 haloes, at http://logrus.uchicago.edu/~aphearin
Sex differences in coping strategies in military survival school.
Schmied, Emily A; Padilla, Genieleah A; Thomsen, Cynthia J; Lauby, Melissa D Hiller; Harris, Erica; Taylor, Marcus K
2015-01-01
A wealth of research has examined psychological responses to trauma among male military service members, but few studies have examined sex differences in response to trauma, such as coping strategies. This study assessed coping strategies used by male and female U.S. service members completing an intensely stressful mock-captivity exercise, compared strategies by sex, and assessed the relationship between coping and posttraumatic stress symptoms (PTSS). Two hundred service members (78% male) completed self-report surveys before and after mock captivity. Surveys assessed demographics, service characteristics, PTSS, and coping strategies used during mock captivity. Participants used seven coping strategies: denial, self-blame, religion, self-distraction, behavioral disengagement, positive reframing, and planning. Women used denial (p≤.05), self-blame (p≤.05), and positive reinterpretation (p≤.05) strategies more frequently than men, and they had higher PTSS levels following the exercise. Structural equation modeling showed that the relationship between sex and PTSS was fully mediated by coping strategies. The results of this study suggest that reducing the use of maladaptive coping strategies may mitigate PTSS among females. Future efforts should target improving coping during highly stressful and traumatic experiences. Copyright © 2014 Elsevier Ltd. All rights reserved.
36 CFR 910.17 - Pedestrian circulation system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT AREA Urban Planning and Design Concerns § 910.17 Pedestrian circulation system...
36 CFR 910.17 - Pedestrian circulation system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT AREA Urban Planning and Design Concerns § 910.17 Pedestrian circulation system...
Carmo-Sousa, Michele; Moreno, Aranzazu; Garzo, Elisa; Fereres, Alberto
2014-06-24
Plant viruses are known to modify the behaviour of their insect vectors, both directly and indirectly, generally adapting to each type of virus-vector relationship in a way that enhances transmission efficiency. Here, we report results of three different studies showing how a virus transmitted in a non-persistent (NP) manner (Cucumber mosaic virus; CMV, Cucumovirus) can induce changes in its host plant, cucumber (Cucumis sativus cv. Marumba) that modifies the behaviour of its aphid vector (Aphis gossypii Glover; Hemiptera: Aphididae) in a way that enhances virus transmission and spread non-viruliferous aphids changed their alighting, settling and probing behaviour activities over time when exposed to CMV-infected and mock-inoculated cucumber plants. Aphids exhibited no preference to migrate from CMV-infected to mock-inoculated plants at short time intervals (1, 10 and 30 min after release), but showed a clear shift in preference to migrate from CMV-infected to mock-inoculated plants 60 min after release. Our free-choice preference assays showed that A. gossypii alates preferred CMV-infected over mock-inoculated plants at an early stage (30 min), but this behaviour was reverted at a later stage and aphids preferred to settle and reproduce on mock-inoculated plants. The electrical penetration graph (EPG) technique revealed a sharp change in aphid probing behaviour over time when exposed to CMV-infected plants. At the beginning (first 15 min) aphid vectors dramatically increased the number of short superficial probes and intracellular punctures when exposed to CMV-infected plants. At a later stage (second hour of recording) aphids diminished their feeding on CMV-infected plants as indicated by much less time spent in phloem salivation and ingestion (E1 and E2). This particular probing behaviour including an early increase in the number of short superficial probes and intracellular punctures followed by a phloem feeding deterrence is known to enhance the transmission efficiency of viruses transmitted in a NP manner. We conclude that CMV induces specific changes in a plant host that modify the alighting, settling and probing behaviour of its main vector A. gossypii, leading to optimum transmission and spread of the virus. Our findings should be considered when modelling the spread of viruses transmitted in a NP manner. Copyright © 2013 Elsevier B.V. All rights reserved.
Glutamine deprivation induces interleukin-8 expression in ataxia telangiectasia fibroblasts.
Kim, Min-Hyun; Kim, Aryung; Yu, Ji Hoon; Lim, Joo Weon; Kim, Hyeyoung
2014-05-01
To investigate whether glutamine deprivation induces expression of inflammatory cytokine interleukin-8 (IL-8) by determining NF-κB activity and levels of oxidative indices (ROS, reactive oxygen species; hydrogen peroxide; GSH, glutathione) in fibroblasts isolated from patients with ataxia telangiectasia (A-T). We used A-T fibroblasts stably transfected with empty vector (Mock) or with human full-length ataxia telangiectasia mutated (ATM) cDNA (YZ5) and mouse embryonic fibroblasts (MEFs) transiently transfected with ATM small interfering RNA (siRNA) or with non-specific control siRNA. The cells were cultured with or without glutamine or GSH. ROS levels were determined using a fluorescence reader and confocal microscopy. IL-8 or murine IL-8 homolog, keratinocyte chemoattractant (KC), and hydrogen peroxide levels in the medium were determined by enzyme-linked immunosorbent assay and colorimetric assay. GSH level was assessed by enzymatic assay, while IL-8 (KC) mRNA level was measured by reverse transcription-polymerase chain reaction (RT-PCR) and/or quantitative real-time PCR. NF-κB DNA-binding activity was determined by electrophoretic mobility shift assay. Catalase activity and ATM protein levels were determined by O2 generation and Western blotting. While glutamine deprivation induced IL-8 expression and increased NF-κB DNA-binding activity in Mock cells, both processes were decreased by treatment of cells with glutamine or GSH or both glutamine and GSH. Glutamine deprivation had no effect on IL-8 expression or NF-κB DNA-binding activity in YZ5 cells. Glutamine-deprived Mock cells had higher oxidative stress indices (increases in ROS and hydrogen peroxide, reduction in GSH) than glutamine-deprived YZ5 cells. In Mock cells, glutamine deprivation-induced oxidative stress indices were suppressed by treatment with glutamine or GSH or both glutamine and GSH. GSH levels and catalase activity were lower in Mock cells than YZ5 cells. MEFs transfected with ATM siRNA and cultured without glutamine showed higher levels of ROS and IL-8 than those transfected with negative control siRNA; increased levels of ROS and IL-8 were suppressed by the treatment of glutamine. Glutamine deprivation induces ROS production, NF-κB activation, and IL-8 expression as well as a reduction in GSH in A-T fibroblasts, all of which are attenuated by glutamine supplementation.
Privacy, Liveliness and Fairness for Reputation
NASA Astrophysics Data System (ADS)
Schiffner, Stefan; Clauß, Sebastian; Steinbrecher, Sandra
In various Internet applications, reputation systems are typical means to collect experiences users make with each other. We present a reputation system that balances the security and privacy requirements of all users involed. Our system provides privacy in the form of information theoretic relationship anonymity w.r.t. users and the reputation provider. Furthermore, it preserves liveliness, i.e., all past ratings can influence the current reputation profile of a user. In addition, mutual ratings are forced to be simultaneous and self rating is prevented, which enforces fairness. What is more, without performing mock interactions - even if all users are colluding - users cannot forge ratings. As far as we know, this is the first protocol proposed that fulfills all these properties simultaneously.
Using a Gravity Model to Predict Circulation in a Public Library System.
ERIC Educational Resources Information Center
Ottensmann, John R.
1995-01-01
Describes the development of a gravity model based upon principles of spatial interaction to predict the circulation of libraries in the Indianapolis-Marion County Public Library (Indiana). The model effectively predicted past circulation figures and was tested by predicting future library circulation, particularly for a new branch library.…
Farahani, Navid; Liu, Zheng; Jutt, Dylan; Fine, Jeffrey L
2017-10-01
- Pathologists' computer-assisted diagnosis (pCAD) is a proposed framework for alleviating challenges through the automation of their routine sign-out work. Currently, hypothetical pCAD is based on a triad of advanced image analysis, deep integration with heterogeneous information systems, and a concrete understanding of traditional pathology workflow. Prototyping is an established method for designing complex new computer systems such as pCAD. - To describe, in detail, a prototype of pCAD for the sign-out of a breast cancer specimen. - Deidentified glass slides and data from breast cancer specimens were used. Slides were digitized into whole-slide images with an Aperio ScanScope XT, and screen captures were created by using vendor-provided software. The advanced workflow prototype was constructed by using PowerPoint software. - We modeled an interactive, computer-assisted workflow: pCAD previews whole-slide images in the context of integrated, disparate data and predefined diagnostic tasks and subtasks. Relevant regions of interest (ROIs) would be automatically identified and triaged by the computer. A pathologist's sign-out work would consist of an interactive review of important ROIs, driven by required diagnostic tasks. The interactive session would generate a pathology report automatically. - Using animations and real ROIs, the pCAD prototype demonstrates the hypothetical sign-out in a stepwise fashion, illustrating various interactions and explaining how steps can be automated. The file is publicly available and should be widely compatible. This mock-up is intended to spur discussion and to help usher in the next era of digitization for pathologists by providing desperately needed and long-awaited automation.
NASA Astrophysics Data System (ADS)
Andersson, P.; Bjelkenstedt, T.; Sundén, E. Andersson; Sjöstrand, H.; Jacobsson-Svärd, S.
Detailed knowledge of the lateral distribution of steam (void) and water in a nuclear fuel assembly is of great value for nuclear reactor operators and fuel manufacturers, with consequences for both reactor safety and economy of operation. Therefore, nuclear relevant two-phase flows are being studied at dedicated thermal-hydraulic test loop, using two-phase flow systems ranging from simplified geometries such as heated circular pipes to full scale mock-ups of nuclear fuel assemblies. Neutron tomography (NT) has been suggested for assessment of the lateral distribution of steam and water in such test loops, motivated by a good ability of neutrons to penetrate the metallic structures of metal pipes and nuclear fuel rod mock-ups, as compared to e.g. conventional X-rays, while the liquid water simultaneously gives comparatively good contrast. However, these stationary test loops require the measurement setup to be mobile, which is often not the case for NT setups. Here, it is acknowledged that fast neutrons of 14 MeV from mobile neutron generators constitute a viable option for a mobile NT system. We present details of the development of neutron tomography for this purpose at the division of Applied Nuclear Physics at Uppsala University. Our concept contains a portable neutron generator, exploiting the fusion reaction of deuterium and tritium, and a detector with plastic scintillator elements designed to achieveadequate spatial and energy resolution, all mounted in a light-weight frame without collimators or bulky moderation to allow for a mobile instrument that can be moved about the stationary thermal hydraulic test sections. The detector system stores event-to-event pulse-height information to allow for discrimination based on the energy deposition in the scintillator elements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, Timothy D; Hollenbach, Daniel F; Shedlock, Daniel
Radiography by Selective Detection (RSD), was investigated for its ability to determine the presence and types of defects in a UO{sub 2} fuel rod surrounded by zirconium cladding. Images created using a Monte Carlo model compared favorably with actual X-ray backscatter images from mock fuel rods. A fuel rod was modeled as a rectangular parallelepiped with zirconium cladding, and pencil beam X-ray sources of 160 kVp (79 keV avg) and 480 kVp (218 keV avg) were generated using the Monte Carlo N-Particle Transport Code to attempt to image void and palladium (Pd) defects in the interior and on the surfacemore » of the fuel pellet. It was found that the 160 kVp spectrum was unable to detect the presence of interior defects, whereas the 480 kVp spectrum detected them with both the standard and the RSD backscatter methods, though the RSD method was very inefficient. It was also found that both energy spectra were able to detect void and Pd defects on the surface using both imaging methods. Additionally, two mock fuel rods were imaged using a backscatter X-ray imaging system, one consisting of hafnium pellets in a Zircaloy-4 cladding and the other consisting of steel pellets in a Zircalloy-4 cladding which was then encased in a steel cladding (a double encapsulation configuration employed in irradiation and experiments). It was found that the system was capable of detecting individual HfO{sub 2} pellets in a Zircaloy-4 cladding and may be capable of detecting individual steel pellets in the double-encapsulated sample. It is expected that the system would also be capable of detecting individual UO{sub 2} pellets in a Zircaloy-4 cladding, though no UO{sub 2} fuel rod was available for imaging.« less
NASA Technical Reports Server (NTRS)
1985-01-01
A mock-up for the development of the Engineering Model (EM) and Flight Model (FM) is introduced which shortens the delay of 7 weeks regarding the previous planned launch date of September 30, to about 3 weeks maintaining the 4 weeks reserve is discussed. As compared with the new assembly integration test (EM-AIT) schedule of March 11, 1985, the EM data handling system is on the critical path. For the attitude measurement and control subsystem, sufficiently flexibility is achieved through combination of dummies and EM hardware to catch up with the existing delays.
NASA Astrophysics Data System (ADS)
Ballarotta, M.; Falahat, S.; Brodeau, L.; Döös, K.
2014-11-01
The thermohaline circulation (THC) and the oceanic heat and freshwater transports are essential for understanding the global climate system. Streamfunctions are widely used in oceanography to represent the THC and estimate the transport of heat and freshwater. In the present study, the regional and global changes of the THC, the transports of heat and freshwater and the timescale of the circulation between the Last Glacial Maximum (LGM, ≈ 21 kyr ago) and the present-day climate are explored using an Ocean General Circulation Model and streamfunctions projected in various coordinate systems. We found that the LGM tropical circulation is about 10% stronger than under modern conditions due to stronger wind stress. Consequently, the maximum tropical transport of heat is about 20% larger during the LGM. In the North Atlantic basin, the large sea-ice extent during the LGM constrains the Gulf Stream to propagate in a more zonal direction, reducing the transport of heat towards high latitudes by almost 50% and reorganising the freshwater transport. The strength of the Atlantic Meridional Overturning Circulation depends strongly on the coordinate system. It varies between 9 and 16 Sv during the LGM, and between 12 to 19 Sv for the present day. Similar to paleo-proxy reconstructions, a large intrusion of saline Antarctic Bottom Water takes place into the Northern Hemisphere basins and squeezes most of the Conveyor Belt circulation into a shallower part of the ocean. These different haline regimes between the glacial and interglacial period are illustrated by the streamfunctions in latitude-salinity coordinates and thermohaline coordinates. From these diagnostics, we found that the LGM Conveyor Belt circulation is driven by an enhanced salinity contrast between the Atlantic and the Pacific basin. The LGM abyssal circulation lifts and makes the Conveyor Belt cell deviate from the abyssal region, resulting in a ventilated upper layer above a deep stagnant layer, and an Atlantic circulation more isolated from the Pacific. An estimate of the timescale of the circulation reveals a sluggish abyssal circulation during the LGM, and a Conveyor Belt circulation that is more vigorous due to the combination of a stronger wind stress and a shortened circulation route.
Haverkort, J J Mark; Leenen, Luke P H
2017-10-01
Presently used evaluation techniques rely on 3 traditional dimensions: reports from observers, registration system data, and observational cameras. Some of these techniques are observer-dependent and are not reproducible for a second review. This proof-of-concept study aimed to test the feasibility of extending evaluation to a fourth dimension, the patient's perspective. Footage was obtained during a large, full-scale hospital trauma drill. Two mock victims were equipped with point-of-view cameras filming from the patient's head. Based on the Major Incident Hospital's first experience during the drill, a protocol was developed for a prospective, standardized method to evaluate a hospital's major incident response from the patient's perspective. The protocol was then tested in a second drill for its feasibility. New insights were gained after review of the footage. The traditional observer missed some of the evaluation points, which were seen on the point-of-view cameras. The information gained from the patient's perspective proved to be implementable into the designed protocol. Use of point-of-view camera recordings from a mock patient's perspective is a valuable addition to traditional evaluation of trauma drills and trauma care. Protocols should be designed to optimize and objectify judgement of such footage. (Disaster Med Public Health Preparedness. 2017;11:594-599).
NASA Astrophysics Data System (ADS)
Dahake, Sandeep; Kuthe, Abhaykumar; Mawale, Mahesh
2017-10-01
This paper aims to describe virtual surgical planning (VSP), computer aided design (CAD) and rapid prototyping (RP) systems for the preoperative planning of accurate treatment of the Brodie's Syndrome. 3D models of the patient's maxilla and mandible were separately generated based on computed tomography (CT) image data and fabricated using RP. During the customized surgical osteotmy guide (CSOG) design process, the correct position was identified and the geometry of the CSOG was generated based on affected mandible of the patient and fabricated by a RP technique. Surgical approach such as preoperative planning and simulation of surgical procedures was performed using advanced software. The VSP and RP assisted CSOG was used to avoid the damage of the adjacent teeth and neighboring healthy tissues. Finally the mock surgery was performed on the biomodel (i.e. diseased RP model) of mandible with reference to the normal maxilla using osteotomy bur with the help of CSOG. Using this CSOG the exact osteotomy of the mandible and the accurate placement of the distractor were obtained. It ultimately improved the accuracy of the surgery in context of the osteotomy and distraction. The time required in cutting the mandible and placement of the distractor was found comparatively less than the regular free hand surgery.
The Automated Circulation Marketplace: Active and Heating Up.
ERIC Educational Resources Information Center
Matthews, Joseph R.
1982-01-01
Predicts that the growing market for automated circulation systems will expand even faster in the near future, given the availability of a wide variety of systems and computer types, which enables libraries of all sizes to obtain a system to fit their needs. Currently there are 301 systems installed. (RAA)
An Integrated Systems Approach: A Description of an Automated Circulation Management System.
ERIC Educational Resources Information Center
Seifert, Jan E.; And Others
These bidding specifications describe requirements for a turn-key automated circulation system for the University of Oklahoma Libraries. An integrated systems approach is planned, and requirements are presented for various subsystems: acquisitions, fund accounting, reserve room, and bibliographic and serials control. Also outlined are hardware…
Yang, F-Y; Bao, Y-Z; Liu, F-S; Zhu, Y-C; Zheng, J; Zhang, J-H; Zheng, X-F; Wei, G-C
2015-04-01
The objective of this study was to compare coronary artery bypass graft (CABG) surgery with non-extracorporeal vs. extracorporeal circulation. The study outcomes included operative time, number of graft vessels, pulmonary infection rates, and systemic inflammatory markers. 96 patients received selective CABG, either with non-extracorporeal (study group; n = 48) or extracorporeal circulation (control group; n = 48). Operative time, pulmonary infection rates, and blood levels of inflammatory markers TNF-α, IL-6, and IL-8 before and 4, 24, and 48 hours after the surgery were quantified. Graft vessels were quantified using computed tomography. Operative time was significantly shorter in study group (4.58 ± 0.91 vs. 5.36 ± 1.12 hours in control group; p < 0.05). The number of graft vessels and pulmonary infection rates were comparable between both techniques. However, systemic inflammatory markers were significantly (p < 0.05) lower in study group at 4 and, partly, 24 hours after the surgery. Extracorporeal circulation prolongs operation and can aggravate systemic inflammatory response. Therefore, CABG with non-extracorporeal circulation offers more beneficial outcomes.
NASA Astrophysics Data System (ADS)
Yoo, Yeon-Jong
The purpose of this study is to investigate the performance and stability of the gas-injection enhanced natural circulation in heavy-liquid-metal-cooled systems. The target system is STAR-LM, which is a 400-MWt-class advanced lead-cooled fast reactor under development by Argonne National Laboratory and Oregon State University. The primary loop of STAR-LM relies on natural circulation to eliminate main circulation pumps for enhancement of passive safety. To significantly increase the natural circulation flow rate for the incorporation of potential future power uprates, the injection of noncondensable gas into the coolant above the core is envisioned ("gas lift pump"). Reliance upon gas-injection enhanced natural circulation raises the concern of flow instability due to the relatively high temperature change in the reactor core and the two-phase flow condition in the riser. For this study, the one-dimensional flow field equations were applied to each flow section and the mixture models of two-phase flow, i.e., both the homogeneous and drift-flux equilibrium models were used in the two-phase region of the riser. For the stability analysis, the linear perturbation technique based on the frequency-domain approach was used by employing the Nyquist stability criterion and a numerical root search method. It has been shown that the thermal power of the STAR-LM natural circulation system could be increased from 400 up to 1152 MW with gas injection under the limiting void fraction of 0.30 and limiting coolant velocity of 2.0 m/s from the steady-state performance analysis. As the result of the linear stability analysis, it has turned out that the STAR-LM natural circulation system would be stable even with gas injection. In addition, through the parametric study, it has been found that the thermal inertia effects of solid structures such as fuel rod and heat exchanger tube should be considered in the stability analysis model. The results of this study will be a part of the optimized stable design of the gas-injection enhanced natural circulation of STAR-LM with substantially improved power level and economical competitiveness. Furthermore, combined with the parametric study, this research could contribute a guideline for the design of other similar heavy-liquid-metal-cooled natural circulation systems with gas injection.
Research on Parallel Three Phase PWM Converters base on RTDS
NASA Astrophysics Data System (ADS)
Xia, Yan; Zou, Jianxiao; Li, Kai; Liu, Jingbo; Tian, Jun
2018-01-01
Converters parallel operation can increase capacity of the system, but it may lead to potential zero-sequence circulating current, so the control of circulating current was an important goal in the design of parallel inverters. In this paper, the Real Time Digital Simulator (RTDS) is used to model the converters parallel system in real time and study the circulating current restraining. The equivalent model of two parallel converters and zero-sequence circulating current(ZSCC) were established and analyzed, then a strategy using variable zero vector control was proposed to suppress the circulating current. For two parallel modular converters, hardware-in-the-loop(HIL) study based on RTDS and practical experiment were implemented, results prove that the proposed control strategy is feasible and effective.
NASA Astrophysics Data System (ADS)
Faranda, D.; Yiou, P.; Alvarez-Castro, M. C. M.
2015-12-01
A combination of dynamical systems and statistical techniques allows for a robust assessment of the dynamical properties of the mid-latitude atmospheric circulation. Extremes at different spatial and time scales are not only associated to exceptionally intense weather structures (e.g. extra-tropical cyclones) but also to rapid changes of circulation regimes (thunderstorms, supercells) or the extreme persistence of weather structure (heat waves, cold spells). We will show how the dynamical systems theory of recurrence combined to the extreme value theory can take into account the spatial and temporal dependence structure of the mid-latitude circulation structures and provide information on the statistics of extreme events.
Design, fabrication and test of a trace contaminant control system
NASA Technical Reports Server (NTRS)
1975-01-01
A trace contaminant control system was designed, fabricated, and evaluated to determine suitability of the system concept to future manned spacecraft. Two different models were considered. The load model initially required by the contract was based on the Space Station Prototype (SSP) general specifications SVSK HS4655, reflecting a change from a 9 man crew to a 6 man crew of the model developed in previous phases of this effort. Trade studies and a system preliminary design were accomplished based on this contaminant load, including computer analyses to define the optimum system configuration in terms of component arrangements, flow rates and component sizing. At the completion of the preliminary design effort a revised contaminant load model was developed for the SSP. Additional analyses were then conducted to define the impact of this new contaminant load model on the system configuration. A full scale foam-core mock-up with the appropriate SSP system interfaces was also fabricated.
Heparin-coated extracorporeal circulation systems in heart surgery.
Tagarakis, Georgios I; Tsilimingas, Nikolaos B
2009-11-01
Despite the progress accomplished in the field of off-pump heart surgery, the vast majority of cardiac operations are still performed with the use of extracorporeal circulation, otherwise known as "heart-lung machine." This valuable tool, however, is connected with various complications, partly deriving from the application of intravenous heparin, necessary for the extracorporeal circuits to function. In order to deal with these complications, which among others include postoperative hemorrhage and systemic inflammatory response, several extracorporeal circulation systems, which contain a heparin-coating on their blood-contacting surfaces, have been developed with patents. The philosophy behind the creation of these systems is that with the controlled absorption and interaction of this heparin with the blood elements, adequate intraoperative anticoagulation with lower doses of systemic heparin and fewer systemic complications can be achieved. The idea of the use of heparin coatings has also been applied in other settings, such as in renal dialysis catheters, ECMO (extracorporeal membrane oxygenation), MECC (minimized extracorporeal circulation) and left ventricle assist devices.
McKillen, John; McNair, Irene; Lagan, Paula; McKay, Karen; McClintock, Julie; Casement, Veronica; Charreyre, Catherine; Allan, Gordon
2016-04-01
Snatch farrowed, colostrum deprived piglets were inoculated with different combinations of porcine circovirus 2, porcine parvovirus and Erysipelothrix rhusiopathiae candidate vaccines. 10 piglets were mock-vaccinated. Following virus challenge with a combined porcine circovirus 2/porcine parvovirus inoculum, all animals were monitored and samples taken for serology, immunohistochemistry and qPCR. At 24 dpc all non-vaccinated animals remaining were exhibiting signs of post-weaning multi-systemic wasting syndrome which was confirmed by laboratory analysis. Details of the study, analysis of samples and performance of the candidate vaccines are described. Copyright © 2016 Elsevier Ltd. All rights reserved.
On the Specification of Upward-Propagating Tides for ICON Science Investigations
NASA Astrophysics Data System (ADS)
Forbes, Jeffrey M.; Zhang, Xiaoli; Hagan, Maura E.; England, Scott L.; Liu, Guiping; Gasperini, Federico
2017-10-01
The National Center for Atmospheric Research (NCAR) Thermosphere Ionosphere Electrodynamics General Circulation Model (TIEGCM) will provide a physics-based context for the interpretation of ICON measurements. To optimize the realism of the model simulations, ICON wind and temperature measurements near the ˜97 km lower boundary of the TIEGCM will be used to specify the upward-propagating tidal spectrum at this altitude. This will be done by fitting a set of basis functions called Hough Mode Extensions (HMEs) to 27-day mean tidal winds and temperatures between 90 and 105 km altitude and between 12 °S and 42 °N latitude on a day-by-day basis. The current paper assesses the veracity of the HME fitting methodology given the restricted latitude sampling and the UT-longitude sampling afforded by the MIGHTI instrument viewing from the ICON satellite, which will be in a circular 27° inclination orbit. These issues are investigated using the output from a reanalysis-driven global circulation model, which contains realistic variability of the important tidal components, as a mock data set. ICON sampling of the model reveals that the 27-day mean diurnal and semidiurnal tidal components replicate well the 27-day mean tidal components obtained from full synoptic sampling of the model, but the terdiurnal tidal components are not faithfully reproduced. It is also demonstrated that reconstructed tidal components based on HME fitting to the model tides between 12 °S and 42 °N latitude provide good approximations to the major tidal components expected to be encountered during the ICON mission. This is because the constraints provided by fitting both winds and temperatures over the 90-105 km height range are adequate to offset the restricted sampling in latitude. The boundary conditions provided by the methodology described herein will greatly enhance the ability of the TIEGCM to provide a physical framework for interpreting atmosphere-ionosphere coupling in ICON observations due to atmospheric tides.
Takatani, Setsuo; Hoshi, Hideo; Tajima, Kennichi; Ohuchi, Katsuhiro; Nakamura, Makoto; Asama, Junichio; Shimshi, Tadahiko; Yoshikawa, Masaharu
2005-01-01
In this study, a seal-less, tiny centrifugal rotary blood pump was designed for low-flow circulatory support in children and infants. The design was targeted to yield a compact and priming volume of 5 ml with a flow rate of 0.5-4 l/min against a head pressure of 40-100 mm Hg. To meet the design requirements, the first prototype had an impeller diameter of 30 mm with six straight vanes. The impeller was supported with a needle-type hydrodynamic bearing and was driven with a six-pole radial magnetic driver. The external pump dimensions included a pump head height of 20 mm, diameter of 49 mm, and priming volume of 5 ml. The weight was 150 g, including the motor driver. In the mock circulatory loop, using fresh porcine blood, the pump yielded a flow of 0.5-4.0 l/min against a head pressure of 40-100 mm Hg at a rotational speed of 1800-4000 rpm using 1/4" inflow and outflow conduits. The maximum flow and head pressure of 5.25 l/min and 244 mm Hg, respectively, were obtained at a rotational speed of 4400 rpm. The maximum electrical-to-hydraulic efficiency occurred at a flow rate of 1.5-3.5 l/min and at a rotational speed of 2000-4400 rpm. The normalized index of hemolysis, which was evaluated using fresh porcine blood, was 0.0076 g/100 l with the impeller in the down-mode and a bearing clearance of 0.1 mm. Further refinement in the bearing and magnetic coupler are required to improve the hemolytic performance of the pump. The durability of the needle-type hydrodynamic bearing and antithrombotic performance of the pump will be performed before clinical applications. The tiny centrifugal blood pump meets the flow requirements necessary to support the circulation of pediatric patients.
Biglino, Giovanni; Giardini, Alessandro; Hsia, Tain-Yen; Figliola, Richard; Taylor, Andrew M.; Schievano, Silvia
2013-01-01
First stage palliation of hypoplastic left heart syndrome, i.e., the Norwood operation, results in a complex physiological arrangement, involving different shunting options (modified Blalock-Taussig, RV-PA conduit, central shunt from the ascending aorta) and enlargement of the hypoplastic ascending aorta. Engineering techniques, both computational and experimental, can aid in the understanding of the Norwood physiology and their correct implementation can potentially lead to refinement of the decision-making process, by means of patient-specific simulations. This paper presents some of the available tools that can corroborate clinical evidence by providing detailed insight into the fluid dynamics of the Norwood circulation as well as alternative surgical scenarios (i.e., virtual surgery). Patient-specific anatomies can be manufactured by means of rapid prototyping and such models can be inserted in experimental set-ups (mock circulatory loops) that can provide a valuable source of validation data as well as hydrodynamic information. Such models can be tuned to respond to differing the patient physiologies. Experimental set-ups can also be compatible with visualization techniques, like particle image velocimetry and cardiovascular magnetic resonance, further adding to the knowledge of the local fluid dynamics. Multi-scale computational models include detailed three-dimensional (3D) anatomical information coupled to a lumped parameter network representing the remainder of the circulation. These models output both overall hemodynamic parameters while also enabling to investigate the local fluid dynamics of the aortic arch or the shunt. As an alternative, pure lumped parameter models can also be employed to model Stage 1 palliation, taking advantage of a much lower computational cost, albeit missing the 3D anatomical component. Finally, analytical techniques, such as wave intensity analysis, can be employed to study the Norwood physiology, providing a mechanistic perspective on the ventriculo-arterial coupling for this specific surgical scenario. PMID:24400277
Regulation of diet-induced adipose tissue and systemic inflammation by salicylates and pioglitazone.
Kim, Myung-Sunny; Yamamoto, Yasuhiko; Kim, Kyungjin; Kamei, Nozomu; Shimada, Takeshi; Liu, Libin; Moore, Kristin; Woo, Ju Rang; Shoelson, Steven E; Lee, Jongsoon
2013-01-01
It is increasingly accepted that chronic inflammation participates in obesity-induced insulin resistance and type 2 diabetes (T2D). Salicylates and thiazolidinediones (TZDs) both have anti-inflammatory and anti-hyperglycemic properties. The present study compared the effects of these drugs on obesity-induced inflammation in adipose tissue (AT) and AT macrophages (ATMs), as well as the metabolic and immunological phenotypes of the animal models. Both drugs improved high fat diet (HFD)-induced insulin resistance. However, salicylates did not affect AT and ATM inflammation, whereas Pioglitazone improved these parameters. Interestingly, HFD and the drug treatments all modulated systemic inflammation as assessed by changes in circulating immune cell numbers and activation states. HFD increased the numbers of circulating white blood cells, neutrophils, and a pro-inflammatory monocyte subpopulation (Ly6C(hi)), whereas salicylates and Pioglitazone normalized these cell numbers. The drug treatments also decreased circulating lymphocyte numbers. These data suggest that obesity induces systemic inflammation by regulating circulating immune cell phenotypes and that anti-diabetic interventions suppress systemic inflammation by normalizing circulating immune phenotypes.
NASA Astrophysics Data System (ADS)
Liu, Zedong; Wan, Xiuquan
2018-04-01
The Atlantic meridional overturning circulation (AMOC) is a vital component of the global ocean circulation and the heat engine of the climate system. Through the use of a coupled general circulation model, this study examines the role of synoptic systems on the AMOC and presents evidence that internally generated high-frequency, synoptic-scale weather variability in the atmosphere could play a significant role in maintaining the overall strength and variability of the AMOC, thereby affecting climate variability and change. Results of a novel coupling technique show that the strength and variability of the AMOC are greatly reduced once the synoptic weather variability is suppressed in the coupled model. The strength and variability of the AMOC are closely linked to deep convection events at high latitudes, which could be strongly affected by the weather variability. Our results imply that synoptic weather systems are important in driving the AMOC and its variability. Thus, interactions between atmospheric weather variability and AMOC may be an important feedback mechanism of the global climate system and need to be taken into consideration in future climate change studies.
Oxidative Burst of Circulating Neutrophils Following Traumatic Brain Injury in Human
Liao, Yiliu; Liu, Peng; Guo, Fangyuan; Zhang, Zhi-Yuan; Zhang, Zhiren
2013-01-01
Besides secondary injury at the lesional site, Traumatic brain injury (TBI) can cause a systemic inflammatory response, which may cause damage to initially unaffected organs and potentially further exacerbate the original injury. Here we investigated plasma levels of important inflammatory mediators, oxidative activity of circulating leukocytes, particularly focusing on neutrophils, from TBI subjects and control subjects with general trauma from 6 hours to 2 weeks following injury, comparing with values from uninjured subjects. We observed increased plasma level of inflammatory cytokines/molecules TNF-α, IL-6 and CRP, dramatically increased circulating leukocyte counts and elevated expression of TNF-α and iNOS in circulating leukocytes from TBI patients, which suggests a systemic inflammatory response following TBI. Our data further showed increased free radical production in leukocyte homogenates and elevated expression of key oxidative enzymes iNOS, COX-2 and NADPH oxidase (gp91phox) in circulating leukocytes, indicating an intense induction of oxidative burst following TBI, which is significantly greater than that in control subjects with general trauma. Furthermore, flow cytometry assay proved neutrophils as the largest population in circulation after TBI and showed significantly up-regulated oxidative activity and suppressed phagocytosis rate for circulating neutrophils following brain trauma. It suggests that the highly activated neutrophils might play an important role in the secondary damage, even outside the injured brain. Taken together, the potent systemic inflammatory response induced by TBI, especially the intensively increase oxidative activity of circulating leukocytes, mainly neutrophils, may lead to a systemic damage, dysfunction/damage of bystander tissues/organs and even further exacerbate secondary local damage. Controlling these pathophysiological processes may be a promising therapeutic strategy and will protect unaffected organs and the injured brain from the secondary damage. PMID:23894384
Farmer, Joseph C
2013-12-24
A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.
NASA Astrophysics Data System (ADS)
Woo, Kyoungsuk
Two-phase natural circulation loops are unstable at low pressure operating conditions. New reactor design relying on natural circulation for both normal and abnormal core cooling is susceptible to different types of flow instabilities. In contrast to forced circulation boiling water reactor (BWR), natural circulation BWR is started up without recirculation pumps. The tall chimney placed on the top of the core makes the system susceptible to flashing during low pressure start-up. In addition, the considerable saturation temperature variation may induce complicated dynamic behavior driven by thermal non-equilibrium between the liquid and steam. The thermal-hydraulic problems in two-phase natural circulation systems at low pressure and low power conditions are investigated through experimental methods. Fuel heat conduction, neutron kinetics, flow kinematics, energetics and dynamics that govern the flow behavior at low pressure, are formulated. A dimensionless analysis is introduced to obtain governing dimensionless groups which are groundwork of the system scaling. Based on the robust scaling method and start-up procedures of a typical natural circulation BWR, the simulation strategies for the transient with and without void reactivity feedback is developed. Three different heat-up rates are applied to the transient simulations to study characteristics of the stability during the start-up. Reducing heat-up rate leads to increase in the period of flashing-induced density wave oscillation and decrease in the system pressurization rate. However, reducing the heat-up rate is unable to completely prevent flashing-induced oscillations. Five characteristic regions of stability are discovered at low pressure conditions. They are stable single-phase, flashing near the separator, intermittent oscillation, sinusoidal oscillation and low subcooling stable regions. Stability maps were acquired for system pressures ranging 100 kPa to 400 kPa. According to experimental investigation, the flow becomes stable below a certain heat flux regardless of the inlet subcooling at the core and system pressure. At higher heat flux, unstable phenomena were indentified within a certain range of inlet subcooling. The unstable region diminishes as the system pressure increases. In natural circulation BWRs, the significant gravitational pressure drop over the tall chimney section induces a Type-I instability. The Type-I instability becomes especially important during low power and pressure conditions during reactor start-up. Under these circumstances the effect of pressure variations on the saturation enthalpy becomes significant. An experimental study shows that the flashing phenomenon in the adiabatic chimney section is dominant during the start-up of a natural circulation BWR. Since flashing occurs outside the core, nuclear feedback effects on the stability are small. Furthermore, the thermal-hydraulic oscillation period is much longer than power fluctuation period caused by void reactivity feedback. In the natural circulation system increasing the inlet restriction reduces the natural circulation flow rate, shifting the unstable region to higher inlet subcooling.
Circulatory response and autonomic nervous activity during gum chewing.
Hasegawa, Yoko; Sakagami, Joe; Ono, Takahiro; Hori, Kazuhiro; Zhang, Min; Maeda, Yoshinobu
2009-08-01
Mastication has been proven to enhance the systemic circulation, with circulatory responses seeming to be largely regulated by autonomic nervous activity via a more complex regulatory system than those of other activities. However, few studies have examined the relationships between changes in autonomic nervous activity and the systemic circulation that are induced by masticatory movement. We investigated changes in the systemic circulation and autonomic nervous activity during gum chewing to clarify the influence of mastication. Electrocardiograms, arterial blood pressure, and masseter electromyograms were taken while chewing gum continuously as indicators of systemic circulation in 10 healthy subjects with normal dentition. Cardiac sympathetic activity and vagus nervous activity, as well as vasomotor sympathetic nervous activity, were evaluated by fluctuation analysis of heart rate and blood pressure. Repeated analysis of variance and multiple comparisons were performed to determine chronological changes in each indicator during gum chewing. Gum chewing increased the heart rate and the mean arterial pressure. Although cardiac sympathetic activity and vagus nervous activity showed significant changes, vasomotor sympathetic nervous activity did not. These results suggest that changes in the autonomic nervous activity of the heart are mainly involved in the enhancement of systemic circulation with gum chewing. This explains some characteristics of autonomic nervous regulation in masticatory movement.
Horowitz, I A; ForsterLee, L
2001-08-01
Mock juries were either permitted to take notes or not and provided with access to the trial transcript during deliberations or were not given access. Juries viewed a videotape of a complex trial involving multiple plaintiffs. Note-taking juries were able to distinguish among differentially worthy plaintiffs when assigning awards while non note takers did not distinguish among the plaintiffs and allocated higher overall compensation. Note-taking was significantly more effective than access to trial transcripts in increasing jury competence. Note-taking juries appeared better able to recognize probative evidence and reject false lures than were non note-taking juries. Limits and implications of the present study were discussed.
Matsuda, Izumi; Ogawa, Tokihiro; Tsuneoka, Michiko; Verschuere, Bruno
2015-03-01
The concealed information test (CIT) can be used to assess whether an individual possesses crime-related information. However, its discrimination performance has room for improvement. We examined whether screening out participants who do not respond distinctively on a pretest improves the diagnosticity of a mock-crime CIT. Before conducting the CIT, we gave a pretest to 152 participants, 80 of whom were assigned as guilty. Pretest screening significantly improved the diagnostic value of the mock-crime CIT; however, it also led to a substantial number of undiagnosed participants (33.6%). Pretest screening holds promise, but its application would benefit from dedicated measures for screening out participants. © 2014 Society for Psychophysiological Research.
ERIC Educational Resources Information Center
Mangset, Marte
2017-01-01
According to classical elite theory, increased circulation is related to increased integration which is thought to increase elites' power. Based on a comparative analysis of some European countries' elite education systems, recruitment to elite positions and degrees of circulation--with a specific focus on administrative elites--this article…
Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szpala, Stanislaw; Kohli, Kirpal S.
Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancymore » of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.« less
Hanaoka, H; Okazaki, Y; Satoh, T; Kaneko, Y; Yasuoka, H; Seta, N; Kuwana, M
2012-10-01
Antibodies against double-stranded DNA (dsDNA) are widely used to diagnose systemic lupus erythematosus (SLE) and evaluate its activity in patients. This study was undertaken to examine the clinical utility of circulating anti-dsDNA antibody-secreting cells for evaluating SLE patients. Anti-dsDNA antibody-secreting cells quantified using an enzyme-linked immunospot assay were detected in the spleen, bone marrow and peripheral blood from MRL/lpr but not in control BALB/c mice. Circulating anti-dsDNA antibody-secreting cells were detected in 29 (22%) of 130 patients with SLE, but in none of 49 with non-SLE connective-tissue disease or 18 healthy controls. The presence of circulating anti-dsDNA antibody-secreting cells was associated with persistent proteinuria, high SLE disease activity index and systemic lupus activity measures, and a high serum anti-dsDNA antibody titre measured with an enzyme-linked immunosorbent assay. The positive predictive value for active disease was 48% for circulating anti-dsDNA antibody-secreting cells versus 17% for serum anti-dsDNA antibodies. A prospective cohort of patients with circulating anti-dsDNA antibodies and inactive SLE showed that the cumulative disease flare-free rate was significantly lower in patients with than without circulating anti-dsDNA antibody-secreting cells (p < 0.001). Circulating anti-dsDNA antibody-secreting cells are a useful biomarker for assessing disease activity in SLE patients.
NASA Astrophysics Data System (ADS)
Vlasov, S. M.; Chichirova, N. D.; Chichirov, A. A.; Vlasova, A. Yu.; Filimonova, A. A.; Prosvirnina, D. V.
2018-02-01
A turbine-condensate cooling system is one of the less stable and most hard-to-control systems of maintaining optimal water chemistry. A laboratory recycling cooling water test facility, UVO-0.3, was developed for physical simulation of innovative zero-discharge water chemistry conditions and improvement of technological flowcharts of stabilization treatment of the initial and circulating water of the recycling cooling systems at thermal power plants. Experiments were conducted in the UVO-0.3 facility to investigate the processes that occur in the recycling water supply system and master new technologies of stabilization of the initial and circulating water. It is shown that, when using untreated initial water, scaling cannot be prevented even under low concentration levels. The main reason for the activation of scale depositing is the desorption of carbon dioxide that results in alkalization of the circulating water and, as a consequence, a displacement of the chemical reaction equilibrium towards the formation of slightly soluble hardness ions. Some techniques, viz., liming and alkalization of the initial water and the by-pass treatment of the circulating water, are considered. New engineering solutions have been developed for reducing the amount of scale-forming substances in the initial and circulating water. The best results were obtained by pretreating the initial water with alkalizing agents and simultaneously bypassing and treating part of the circulating water. The obtained experimental data underlie the process flowcharts of stabilization treatment of the initial and circulating TPP water that ensure scale-free and noncorrosive operation and meet the corresponding environmental requirements. Under the bypassing, the specific rates of the agents and the residual hardness are reduced compared with the conventional pretreatment.
NASA Technical Reports Server (NTRS)
Nese, Jon M.; Dutton, John A.
1993-01-01
The predictability of the weather and climatic states of a low-order moist general circulation model is quantified using a dynamic systems approach, and the effect of incorporating a simple oceanic circulation on predictability is evaluated. The predictability and the structure of the model attractors are compared using Liapunov exponents, local divergence rates, and the correlation and Liapunov dimensions. It was found that the activation of oceanic circulation increases the average error doubling time of the atmosphere and the coupled ocean-atmosphere system by 10 percent and decreases the variance of the largest local divergence rate by 20 percent. When an oceanic circulation develops, the average predictability of annually averaged states is improved by 25 percent and the variance of the largest local divergence rate decreases by 25 percent.
Patron Use of an Online Circulation System in Known-Item Searching.
ERIC Educational Resources Information Center
Specht, Jerry
1980-01-01
A study of patron use of the University of Illinois online circulation system (LCS) found that 56 percent of original known item searches and 86 percent of location searches were successful, and that graduate students use the system very differently from the way undergraduates use it. (FM)
NASA Astrophysics Data System (ADS)
Chen, G. B.; Zhong, Y. K.; Zheng, X. L.; Li, Q. F.; Xie, X. M.; Gan, Z. H.; Huang, Y. H.; Tang, K.; Kong, B.; Qiu, L. M.
2003-12-01
A novel gas-phase inlet configuration in the natural circulation system instead of the liquid-phase inlet is introduced to cool down a cryogenic pump system from room temperature to cryogenic temperatures, effectively. The experimental apparatus is illustrated and test process is described. Heat transfer and pressure drop data during the cool-down process are recorded and portrayed. By contrast with liquid-phase inlet configuration, experimental results demonstrate that the natural circulation with the gas-phase inlet configuration is an easier and more controllable way to cool down the pump system and maintain it at cryogenic temperatures.
Chapple, Kimberley; Kowanko, Inge; Harvey, Peter; Chong, Alwin; Battersby, Malcolm
2016-01-01
This paper reports on a pilot qualitative study investigating Aboriginal participants' perspectives of the Flinders Living Well Smoke Free (LWSF) 'training intervention'. Health workers nationally have been trained in this program, which offers a self-management approach to reducing smoking among Aboriginal clients. A component of the training involves Aboriginal clients volunteering their time in a mock care-planning session providing the health workers with an opportunity to practise their newly acquired skills. During this simulation, the volunteer clients receive one condensed session of the LWSF intervention imitating how the training will be implemented when the health workers have completed the training. For the purpose of this study, 10 Aboriginal clients who had been volunteers in the mock care-planning process, underwent a semi-structured interview at seven sites in Australia, including mainstream health services, Aboriginal community controlled health services and remote Aboriginal communities. The study aimed to gauge their perspectives of the training intervention they experienced. Early indications suggest that Aboriginal volunteer clients responded positively to the process, with many reporting substantial health behaviour change or plans to make changes since taking part in this mock care-planning exercise. Enablers of the intervention are discussed along with factors to be considered in the training program.
Heat generation and hemolysis at the shaft seal in centrifugal blood pumps.
Araki, K; Taenaka, Y; Wakisaka, Y; Masuzawa, T; Tatsumi, E; Nakatani, T; Baba, Y; Yagura, A; Eya, K; Toda, K
1995-01-01
The heat and hemolysis around a shaft seal were investigated. Materials were original pumps (Nikkiso HMS-15:N-original, and 3M Delphin:D-original), vane-removed pumps (Nvane(-), Dvane(-)), and a small chamber with a shaft coiled by nichrome wire (mock pump). The original pumps were driven at 500 mmHg and 5 L/min, and vane-removed pumps were driven at the same rotation number. An electrical powers of 0, 0.5, 2, and 10 W was supplied to the mock pumps. In vitro hemolytic testing showed that hemolytic indices were 0.027 g/100 L in N-original, 0.013 in Nvane(-), 0.061 in D-original, and 0.012 in Dvane(-). Measurement of heat with a thermally insulated water chamber showed total heat within the pump of 8.62 and 10.85 W, and heat at the shaft seal of 0.87 and 0.62 W in the Nikkiso and Delphin pumps, respectively. Hemolysis and heat generation of mock pumps remained low. The results indicate that the heat generated around the shaft seal was minimal. Hemolysis at the shaft-seal was considerable but not major. Local heat did not affect hemolysis. It was concluded that the shaft-seal affected hemolysis, not by local heat but friction itself.
Experimental investigation of MHD pressure losses in a mock-up of a liquid metal blanket
NASA Astrophysics Data System (ADS)
Mistrangelo, C.; Bühler, L.; Brinkmann, H.-J.
2018-03-01
Experiments have been performed to investigate the influence of a magnetic field on liquid metal flows in a scaled mock-up of a helium cooled lead lithium (HCLL) blanket. During the experiments pressure differences between points on the mock-up have been recorded for various values of flow rate and magnitude of the imposed magnetic field. The main contributions to the total pressure drop in the test-section have been identified as a function of characteristic flow parameters. For sufficiently strong magnetic fields the non-dimensional pressure losses are practically independent on the flow rate, namely inertia forces become negligible. Previous experiments on MHD flows in a simplified test-section for a HCLL blanket showed that the main contributions to the total pressure drop in a blanket module originate from the flow in the distributing and collecting manifolds. The new experiments confirm that the largest pressure drops occur along manifolds and near the first wall of the blanket module, where the liquid metal passes through small openings in the stiffening plates separating two breeder units. Moreover, the experimental data shows that with the present manifold design the flow does not distribute homogeneously among the 8 stacked boxes that form the breeding zone.
NASA Astrophysics Data System (ADS)
Landrieu, J.; Père, C.; Rollier, J.; Castandet, S.; Schotte, G.
2011-09-01
Our multidisciplinary team has virtually reconstructed the greatest church of the Romanesque period in Europe. The third church of the Abbey of Cluny (12th c.) has been destroyed after the French Revolution, leaving only 8% of the building standing. Many documents have been studied, to include the latest archaeological knowledge in the virtual model. Most remains have been scanned for CAD restitution. The mock-up of the church needed 1600 different numerical files, including the scanned pieces and the anastylosis of a Romanesque portal, a Gothic façade and a mosaic pavement. We faced various difficulties to assemble the different elements of the huge building, and to include the digitized parts. Our workflow consisted in generating geometrical shapes of the church, enriched with metadata such as texture, material... The whole mock up was finally exported to dedicated software to run the rendering step. Our work consisted in creating a whole database of 3D models as well as 2D sources (plans, engravings, pictures...) accessible by the scientific community. The scientific perspectives focus on a representation in virtual immersion of the grand church at scale 1 and an access to the digital mock-up through Augmented Reality.
Taglieri, Catherine A; Crosby, Steven J; Zimmerman, Kristin; Schneider, Tulip; Patel, Dhiren K
2017-06-01
Objective. To assess the effect of incorporating virtual patient activities in a pharmacy skills lab on student competence and confidence when conducting real-time comprehensive clinic visits with mock patients. Methods. Students were randomly assigned to a control or intervention group. The control group completed the clinic visit prior to completing virtual patient activities. The intervention group completed the virtual patient activities prior to the clinic visit. Student proficiency was evaluated in the mock lab. All students completed additional exercises with the virtual patient and were subsequently assessed. Student impressions were assessed via a pre- and post-experience survey. Results. Student performance conducting clinic visits was higher in the intervention group compared to the control group. Overall student performance continued to improve in the subsequent module. There was no change in student confidence from pre- to post-experience. Student rating of the ease of use and realistic simulation of the virtual patient increased; however, student rating of the helpfulness of the virtual patient decreased. Despite student rating of the helpfulness of the virtual patient program, student performance improved. Conclusion. Virtual patient activities enhanced student performance during mock clinic visits. Students felt the virtual patient realistically simulated a real patient. Virtual patients may provide additional learning opportunities for students.
Perceived credibility and eyewitness testimony of children with intellectual disabilities.
Henry, L; Ridley, A; Perry, J; Crane, L
2011-04-01
Although children with intellectual disabilities (ID) often provide accurate witness testimony, jurors tend to perceive their witness statements to be inherently unreliable. The current study explored the free recall transcripts of child witnesses with ID who had watched a video clip, relative to those of typically developing (TD) age-matched children, and assessed how mock jurors perceived these transcripts in the absence of knowledge of group (ID or TD) membership. A further aim of this research was to determine whether perceptions of credibility were associated with levels of free recall and witness characteristics (anxiety and mental age). Mock jurors rated the testimony of children with ID as less credible than that of a TD age-matched comparison group. This was largely because of the transcripts of the children with ID containing fewer details than those of the TD children. Anxiety and mental age were found to have no effect on perceived levels of credibility. It appears that even in the absence of knowledge of whether a child does or does not have ID, this factor still affects perceptions of credibility among mock jurors. Our findings suggest that fundamental differences in the quality of the witness transcripts lead to lower perceptions of credibility for children with ID. © 2011 The Authors. Journal of Intellectual Disability Research © 2011 Blackwell Publishing Ltd.
Dong, Ming; Fisher, Carolyn; Añez, Germán; Rios, Maria; Nakhasi, Hira L.; Hobson, J. Peyton; Beanan, Maureen; Hockman, Donna; Grigorenko, Elena; Duncan, Robert
2016-01-01
Aims To demonstrate standardized methods for spiking pathogens into human matrices for evaluation and comparison among diagnostic platforms. Methods and Results This study presents detailed methods for spiking bacteria or protozoan parasites into whole blood and virus into plasma. Proper methods must start with a documented, reproducible pathogen source followed by steps that include standardized culture, preparation of cryopreserved aliquots, quantification of the aliquots by molecular methods, production of sufficient numbers of individual specimens and testing of the platform with multiple mock specimens. Results are presented following the described procedures that showed acceptable reproducibility comparing in-house real-time PCR assays to a commercially available multiplex molecular assay. Conclusions A step by step procedure has been described that can be followed by assay developers who are targeting low prevalence pathogens. Significance and Impact of Study The development of diagnostic platforms for detection of low prevalence pathogens such as biothreat or emerging agents is challenged by the lack of clinical specimens for performance evaluation. This deficit can be overcome using mock clinical specimens made by spiking cultured pathogens into human matrices. To facilitate evaluation and comparison among platforms, standardized methods must be followed in the preparation and application of spiked specimens. PMID:26835651
Modjadidi, Karima; Kovera, Margaret Bull
2018-06-01
We investigated whether watching a videotaped photo array administration or expert testimony could sensitize jurors to the suggestiveness of single-blind eyewitness identification procedures. Mock jurors recruited from the community (N = 231) watched a videotaped simulation of a robbery trial in which the primary evidence against the defendant was an eyewitness identification. We varied whether the witness made an identification from a single- or double-blind photo array, the evidence included a videotape of the photo array procedure, and an expert testified about the effects of single-blind identification procedures on administrators' behaviors and witness accuracy. Watching the videotaped photo array administration sensitized mock jurors to the suggestiveness of the single-blind procedure, causing them to be less likely to convict a defendant identified through single-rather than double-blind procedures. Exposure to the videotaped procedure also decreased the favorability of mock jurors' ratings of the eyewitness, irrespective of whether the lineup was conducted by a single-blind administrator. Expert testimony did not sensitize jurors to administrator bias. Thus, videotaping identification procedures could serve as an important procedural reform that both preserves a record of whether the lineup administration was suggestive and might improve jurors' evaluations of eyewitness evidence. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Creation of a Mock Universe: Photometric Astronomy on Simulation
NASA Astrophysics Data System (ADS)
Nene, Ajinkya; Rodriguez, Aldo; Primack, Joel R.
2016-01-01
A major focus in astronomy is to understand how galaxies form and evolve in the Universe. The current model known as ΛCDM explains that galaxies form and evolve in halos composed of cold dark matter. In an effort to understand galactic processes in relation to halos, researchers have developed statistical methods to connect galaxies to their halos. One of these approaches is abundance matching: a technique in which the galaxy number density of a property is connected to a theoretical halo number density. In this study, we exploit the abundance matching technique and create a massive photometric mock catalog. We populate millions of dark matter halos in the Bolshoi-Planck Simulation with highly defined galaxies that each has: luminosities, magnitudes, fluxes, masses, and Sérsic profiles. Our catalog acts as an interface between cold dark matter theory and observations: astronomers can use this mock galaxy catalog to compare ΛCDM predictions to observations as well as constrain galaxy formation models. Using our catalog, we can make powerful predictions about both theoretical data and about future astronomical surveys. We demonstrate the usability of our catalog through angular power spectra. Specifically, we shed light on the controversial intrahalo light phenomena. We emphasize that this is the first catalog of this accuracy and size and has incredible potential for application.
Mercado, Francisco; Almanza, Angélica; Rubio, Nazario; Soto, Enrique
2018-06-11
Multiple sclerosis (MS) is a high prevalence degenerative disease characterized at the cellular level by glial and neuronal cell death. The causes of cell death during the disease course are not fully understood. In this work we demonstrate that in a MS model induced by Theiler's murine encephalomyelitis virus (TMEV) infection, the inward rectifier (Kir) 4.1 potassium channel subunit is overexpressed in astrocytes. In voltage clamp experiments the inward current density from TMEV-infected astrocytes was significantly larger than in mock-infected ones. The cRNA hybridization analysis from mock- and TMEV-infected cells showed an upregulation of a potassium transport channel coding sequence. We validated this mRNA increase by RT-PCR and quantitative PCR using Kir 4.1 specific primers. Western blotting experiments confirmed the upregulation of Kir 4.1, and alignment between sequences provided the demonstration that the over-expressed gene encodes for a Kir family member. Flow cytometry showed that the Kir 4.1 protein is located mainly in the cell membrane in mock and TMEV-infected astrocytes. Our results demonstrate an increase in K + inward current in TMEV-infected glial cells, this increment may reduce the neuronal depolarization, contributing to cell resilience mechanisms. Copyright © 2018 Elsevier B.V. All rights reserved.
Event-driven management algorithm of an Engineering documents circulation system
NASA Astrophysics Data System (ADS)
Kuzenkov, V.; Zebzeev, A.; Gromakov, E.
2015-04-01
Development methodology of an engineering documents circulation system in the design company is reviewed. Discrete event-driven automatic models using description algorithms of project management is offered. Petri net use for dynamic design of projects is offered.
Staff Training Aspects of Circulation System Implementation.
ERIC Educational Resources Information Center
Juergens, Bonnie
1979-01-01
Presents program guidelines for training library staff in the operation and use of automated library circulation systems. Advice is given on the qualificatons of the training coordinator, levels of training, training and training aids, vendor responsibilities and time frame. (RAA)
Egge, Elianne; Bittner, Lucie; Andersen, Tom; Audic, Stéphane; de Vargas, Colomban; Edvardsen, Bente
2013-01-01
Next generation sequencing of ribosomal DNA is increasingly used to assess the diversity and structure of microbial communities. Here we test the ability of 454 pyrosequencing to detect the number of species present, and assess the relative abundance in terms of cell numbers and biomass of protists in the phylum Haptophyta. We used a mock community consisting of equal number of cells of 11 haptophyte species and compared targeting DNA and RNA/cDNA, and two different V4 SSU rDNA haptophyte-biased primer pairs. Further, we tested four different bioinformatic filtering methods to reduce errors in the resulting sequence dataset. With sequencing depth of 11000–20000 reads and targeting cDNA with Haptophyta specific primers Hap454 we detected all 11 species. A rarefaction analysis of expected number of species recovered as a function of sampling depth suggested that minimum 1400 reads were required here to recover all species in the mock community. Relative read abundance did not correlate to relative cell numbers. Although the species represented with the largest biomass was also proportionally most abundant among the reads, there was generally a weak correlation between proportional read abundance and proportional biomass of the different species, both with DNA and cDNA as template. The 454 sequencing generated considerable spurious diversity, and more with cDNA than DNA as template. With initial filtering based only on match with barcode and primer we observed 100-fold more operational taxonomic units (OTUs) at 99% similarity than the number of species present in the mock community. Filtering based on quality scores, or denoising with PyroNoise resulted in ten times more OTU99% than the number of species. Denoising with AmpliconNoise reduced the number of OTU99% to match the number of species present in the mock community. Based on our analyses, we propose a strategy to more accurately depict haptophyte diversity using 454 pyrosequencing. PMID:24069303
Park, In Sook; Suh, Yeon Ok; Park, Hae Sook; Kang, So Young; Kim, Kwang Sung; Kim, Gyung Hee; Choi, Yeon-Hee; Kim, Hyun-Ju
2017-01-01
The purpose of this study was to improve the quality of items on the Korean Nursing Licensing Examination by developing and evaluating case-based items that reflect integrated nursing knowledge. We conducted a cross-sectional observational study to develop new case-based items. The methods for developing test items included expert workshops, brainstorming, and verification of content validity. After a mock examination of undergraduate nursing students using the newly developed case-based items, we evaluated the appropriateness of the items through classical test theory and item response theory. A total of 50 case-based items were developed for the mock examination, and content validity was evaluated. The question items integrated 34 discrete elements of integrated nursing knowledge. The mock examination was taken by 741 baccalaureate students in their fourth year of study at 13 universities. Their average score on the mock examination was 57.4, and the examination showed a reliability of 0.40. According to classical test theory, the average level of item difficulty of the items was 57.4% (80%-100% for 12 items; 60%-80% for 13 items; and less than 60% for 25 items). The mean discrimination index was 0.19, and was above 0.30 for 11 items and 0.20 to 0.29 for 15 items. According to item response theory, the item discrimination parameter (in the logistic model) was none for 10 items (0.00), very low for 20 items (0.01 to 0.34), low for 12 items (0.35 to 0.64), moderate for 6 items (0.65 to 1.34), high for 1 item (1.35 to 1.69), and very high for 1 item (above 1.70). The item difficulty was very easy for 24 items (below -2.0), easy for 8 items (-2.0 to -0.5), medium for 6 items (-0.5 to 0.5), hard for 3 items (0.5 to 2.0), and very hard for 9 items (2.0 or above). The goodness-of-fit test in terms of the 2-parameter item response model between the range of 2.0 to 0.5 revealed that 12 items had an ideal correct answer rate. We surmised that the low reliability of the mock examination was influenced by the timing of the test for the examinees and the inappropriate difficulty of the items. Our study suggested a methodology for the development of future case-based items for the Korean Nursing Licensing Examination.
Congdon, B S; Coutts, B A; Renton, M; Flematti, G R; Jones, R A C
2017-09-15
Pea seed-borne mosaic virus (PSbMV) infection causes a serious disease of field pea (Pisum sativum) crops worldwide. The PSbMV transmission efficiencies of five aphid species previously found landing in south-west Australian pea crops in which PSbMV was spreading were studied. With plants of susceptible pea cv. Kaspa, the transmission efficiencies of Aphis craccivora, Myzus persicae, Acyrthosiphon kondoi and Rhopalosiphum padi were 27%, 26%, 6% and 3%, respectively. Lipaphis erysimi did not transmit PSbMV in these experiments. The transmission efficiencies found for M. persicae and A. craccivora resembled earlier findings, but PSbMV vector transmission efficiency data were unavailable for A. kondoi, R. padi and L. erysimi. With plants of partially PSbMV resistant pea cv. PBA Twilight, transmission efficiencies of M. persicae, A. craccivora and R. padi were 16%, 12% and 1%, respectively, reflecting putative partial resistance to aphid inoculation. To examine aphid alighting preferences over time, free-choice assays were conducted with two aphid species representing efficient (M. persicae) and inefficient (R. padi) vector species. For this, alatae were set free on multiple occasions (10-15 repetitions each) amongst PSbMV-infected and mock-inoculated pea or faba bean (Vicia faba) plants. Following release, non-viruliferous R. padi alatae exhibited a general preference for PSbMV-infected pea and faba bean plants after 30min-4h, but preferred mock-inoculated plants after 24h. In contrast, non-viruliferous M. persicae alatae alighted on mock-inoculated pea plants preferentially for up to 48h following their release. With faba bean, M. persicae preferred infected plants at the front of assay cages, but mock-inoculated ones their backs, apparently due to increased levels of natural light there. When preliminary analyses were performed to detect PSbMV-induced changes in the volatile organic compound profiles of pea and faba bean plants, higher numbers of volatiles representing a range of compound groups (such as aldehydes, ketones and esters) were found in the headspaces of PSbMV-infected than of mock-inoculated pea or faba bean plants. This indicates PSbMV induces physiological changes in these hosts which manifest as altered volatile emissions. These alterations could be responsible for the differences in alighting preferences. Information from this study enhances understanding of virus-vector relationships in the PSbMV-pea and faba bean pathosystems. Copyright © 2017 Elsevier B.V. All rights reserved.
Bellofiore, Alessandro; Chesler, Naomi C
2013-07-01
The right ventricle (RV) is a pulsatile pump, the efficiency of which depends on proper hemodynamic coupling with the compliant pulmonary circulation. The RV and pulmonary circulation exhibit structural and functional differences with the more extensively investigated left ventricle (LV) and systemic circulation. In light of these differences, metrics of LV function and efficiency of coupling to the systemic circulation cannot be used without modification to characterize RV function and efficiency of coupling to the pulmonary circulation. In this article, we review RV physiology and mechanics, established and novel methods for measuring RV function and hemodynamic coupling, and findings from application of these methods to RV function and coupling changes with pulmonary hypertension. We especially focus on non-invasive measurements, as these may represent the future for clinical monitoring of disease progression and the effect of drug therapies.
Multisensor robotic system for autonomous space maintenance and repair
NASA Technical Reports Server (NTRS)
Abidi, M. A.; Green, W. L.; Chandra, T.; Spears, J.
1988-01-01
The feasibility of realistic autonomous space manipulation tasks using multisensory information is demonstrated. The system is capable of acquiring, integrating, and interpreting multisensory data to locate, mate, and demate a Fluid Interchange System (FIS) and a Module Interchange System (MIS). In both cases, autonomous location of a guiding light target, mating, and demating of the system are performed. Implemented visio-driven techniques are used to determine the arbitrary two-dimensional position and orientation of the mating elements as well as the arbitrary three-dimensional position and orientation of the light targets. A force/torque sensor continuously monitors the six components of force and torque exerted on the end-effector. Both FIS and MIS experiments were successfully accomplished on mock-ups built for this purpose. The method is immune to variations in the ambient light, in particular because of the 90-minute day-night shift in space.
Hird, H J; Brown, M K
2017-11-01
The identification of samples at a crime scene which require forensic DNA typing has been the focus of recent research interest. We propose a simple, but sensitive analysis system which can be deployed at a crime scene to identify crime scene stains as human or non-human. The proposed system uses the isothermal amplification of DNA in a rapid assay format, which returns results in as little as 30min from sampling. The assay system runs on the Genie II device, a proven in-field detection system which could be deployed at a crime scene. The results presented here demonstrate that the system was sufficiently specific and sensitive and was able to detect the presence of human blood, semen and saliva on mock forensic samples. Copyright © 2017. Published by Elsevier B.V.
A STRATEGY FOR PROTECTING CIRCULATING SEAWATER SYSTEMS FROM OIL SPILLS
A strategy is described for establishing a simple, inexpensive monitoring program for determining approximate levels of petroleum hydrocarbons in ambient water collected near intake structures of circulating seawater systems. The ambient water is obtained from the depth of intake...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biancardi, F.R.; Michels, H.H.; Sienel, T.H.
1996-10-01
The purpose of this program was to conduct experimental and analytical efforts to determine lubricant circulation characteristics of new HFC/POE pairs and HFC/mineral oil pairs in a representative central residential HVAC system and to compare their behavior with the traditional HCFC-22/mineral oil (refrigerant/lubricant) pair. A dynamic test facility was designed and built to conduct the experimental efforts. This facility provided a unique capability to visually and physically measure oil circulation rates, on-line, in operating systems. A unique on-line ultraviolet-based measurement device was used to obtain detailed data on the rate and level of lubricant oil circulated within the operating heatmore » pump system. The experimental and analytical data developed during the program are presented as a function of vapor velocity, refrigerant/lubricant viscosity, system features and equipment. Both visual observations and instrumentation were used to understand ``worst case`` oil circulation situations. This report is presented in two volumes. Volume 1 contains a complete description of the program scope, objective, test results summary, conclusions, description of test facility and recommendations for future effort. Volume 2 contains all of the program test data essentially as taken from the laboratory dynamic test facility during the sequence of runs.« less
ERIC Educational Resources Information Center
Wanger, Judith; And Others
Designed to facilitate communications in future automation projects between library and data processing personnel, especially those projects involving the use of automated systems in the service of disabled patrons, this guide identifies and describes a master set of major circulation system requirements and design considerations, and illustrates…
Library Specifications for a New Circulation System for Concordia University Libraries.
ERIC Educational Resources Information Center
Tallon, James
This study of library requirements for a new circulation system is organized into three sections: (1) items required for initial implementation in July 1982; (2) items relating to notice generation and activity statistics, with implementation expected by fall 1982; and (3) items provided in the system as initially implemented, with additional…
Lawrenson, John; Eyskens, Benedicte; Vlasselaers, Dirk; Gewillig, Marc
2003-08-01
In all patients undergoing cardiac surgery, the effective delivery of oxygen to the tissues is of paramount importance. In the patient with relatively normal cardiac structures, the pulmonary and systemic circulations are relatively independent of each other. In the patient with a functional single ventricle, the pulmonary and systemic circulations are dependent on the same pump. As a consequence of this interdependency, the haemodynamic changes following complex palliative procedures, such as the Norwood operation, can be difficult to understand. Comparison of the newly created surgical connections to a simple set of direct current electrical circuits may help the practitioner to successfully care for the patient. In patients undergoing complex palliations, the pulmonary and systemic circulations can be compared to two circuits in parallel. Manipulations of variables, such as resistance or flow, in one circuit, can profoundly affect the performance of the other circuit. A large pulmonary flow might result in a large increase in the saturation of haemoglobin with oxygen returning to the heart via the pulmonary veins at the expense of a decreased systemic flow. Accurate balancing of these parallel circulations requires an appreciation of all interventions that can affect individual components of both circulations.
A stratospheric balloon experiment to test the Huygens atmospheric structure instrument (HASI)
NASA Astrophysics Data System (ADS)
Fulchignoni, M.; Aboudan, A.; Angrilli, F.; Antonello, M.; Bastianello, S.; Bettanini, C.; Bianchini, G.; Colombatti, G.; Ferri, F.; Flamini, E.; Gaborit, V.; Ghafoor, N.; Hathi, B.; Harri, A.-M.; Lehto, A.; Lion Stoppato, P. F.; Patel, M. R.; Zarnecki, J. C.
2004-08-01
We developed a series of balloon experiments parachuting a 1:1 scale mock-up of the Huygens probe from an altitude just over 30 km to simulate at planetary scale the final part of the descent of the probe through Titan's lower atmosphere. The terrestrial atmosphere represents a natural laboratory where most of the physical parameters meet quite well the bulk condition of Titan's environment, in terms of atmosphere composition, pressure and mean density ranges, though the temperature range will be far higher. The probe mock-up consists of spares of the HASI sensor packages, housekeeping sensors and other dedicated sensors, and also incorporates the Huygens Surface Science Package (SSP) Tilt sensor and a modified version of the Beagle 2 UV sensor, for a total of 77 acquired sensor channels, sampled during ascent, drift and descent phase. An integrated data acquisition and instrument control system, simulating the HASI data-processing unit (DPU), has been developed, based on PC architecture and soft-real-time application. Sensor channels were sampled at the nominal HASI data rates, with a maximum rate of 1 kHz. Software has been developed for data acquisition, onboard storage and telemetry transmission satisfying all requests for real-time monitoring, diagnostic and redundancy. The mock-up of the Huygens probe mission was successfully launched for the second time (first launch in summer 2001, see Gaborit et al., 2001) with a stratospheric balloon from the Italian Space Agency Base "Luigi Broglio" in Sicily on May 30, 2002, and recovered with all sensors still operational. The probe was lifted to an altitude of 32 km and released to perform a parachuted descent lasting 53 min, to simulate the Huygens mission at Titan. Preliminary aerodynamic study of the probe has focused upon the achievement of a descent velocity profile reproducing the expected profile of Huygens probe descent into Titan. We present here the results of this experiment discussing their relevance in the analysis of the data which will be obtained during the Huygens mission at Titan.
Evaluation of an Algorithm to Predict Menstrual-Cycle Phase at the Time of Injury.
Tourville, Timothy W; Shultz, Sandra J; Vacek, Pamela M; Knudsen, Emily J; Bernstein, Ira M; Tourville, Kelly J; Hardy, Daniel M; Johnson, Robert J; Slauterbeck, James R; Beynnon, Bruce D
2016-01-01
Women are 2 to 8 times more likely to sustain an anterior cruciate ligament (ACL) injury than men, and previous studies indicated an increased risk for injury during the preovulatory phase of the menstrual cycle (MC). However, investigations of risk rely on retrospective classification of MC phase, and no tools for this have been validated. To evaluate the accuracy of an algorithm for retrospectively classifying MC phase at the time of a mock injury based on MC history and salivary progesterone (P4) concentration. Descriptive laboratory study. Research laboratory. Thirty-one healthy female collegiate athletes (age range, 18-24 years) provided serum or saliva (or both) samples at 8 visits over 1 complete MC. Self-reported MC information was obtained on a randomized date (1-45 days) after mock injury, which is the typical timeframe in which researchers have access to ACL-injured study participants. The MC phase was classified using the algorithm as applied in a stand-alone computational fashion and also by 4 clinical experts using the algorithm and additional subjective hormonal history information to help inform their decision. To assess algorithm accuracy, phase classifications were compared with the actual MC phase at the time of mock injury (ascertained using urinary luteinizing hormone tests and serial serum P4 samples). Clinical expert and computed classifications were compared using κ statistics. Fourteen participants (45%) experienced anovulatory cycles. The algorithm correctly classified MC phase for 23 participants (74%): 22 (76%) of 29 who were preovulatory/anovulatory and 1 (50%) of 2 who were postovulatory. Agreement between expert and algorithm classifications ranged from 80.6% (κ = 0.50) to 93% (κ = 0.83). Classifications based on same-day saliva sample and optimal P4 threshold were the same as those based on MC history alone (87.1% correct). Algorithm accuracy varied during the MC but at no time were both sensitivity and specificity levels acceptable. These findings raise concerns about the accuracy of previous retrospective MC-phase classification systems, particularly in a population with a high occurrence of anovulatory cycles.
Selective reduction of afterload in right heart assist therapy: a mock loop study†.
Hsu, Po-Lin; Hatam, Nima; Unterkofler, Jan; Goetzenich, Andreas; McIntyre, Madeleine; Wong, Kai Chun; Egger, Christina; Schmitz-Rode, Thomas; Autschbach, Rüdiger; Steinseifer, Ulrich
2014-07-01
The treatment of right ventricular failure is closely linked to effects on pulmonary vascular resistance and thus the right ventricular (RV) afterload. Medical therapy includes afterload-decreasing drugs such as nitric oxide and prostacycline. However, current devices for mechanical unloading of the right ventricle aim at a decrease in preload increasing the pulmonary volume loading. In our concept study, we tested a minimally invasive right ventricular assist device (MIRVAD) that specifically reduces the afterload. The MIRVAD is supposed to be a foldable device for temporary transvascular placement in the pulmonary artery. We incorporated a MIRVAD prototype into a mock circulatory loop that can reproduce haemodynamic interaction between the pump and the physiological system. Pulmonary hypertension (PH), right heart failure (RHF) and MIRVAD-assisted cases were simulated. The key haemodynamic parameters for RV unloading were recorded. Mock loop simulation attested to a sufficient right ventricular unloading by serial application of a miniaturized impeller pump in the pulmonary artery. The afterload, represented by the pulmonary arterial root pressure, was recovered to the healthy range (32.62-10.93 mmHg) for the simulated PH case. In the simulated RHF case, the impaired pulmonary perfusion increased from 43.4 to 88.8% of the healthy level and the total ventricular work reduced from 0.381 to 0.197 J at a pump speed of 3500 rpm. At pump speeds higher than 3500 rpm, the pulmonary valve remains constantly open and the right ventricular configuration changes into a simple perfused hollow body. The feasibility of RV unloading by a selective decrease in RV afterload was proved in principle. By alternation of the pump speed, gradual reloading in sense of a myocardial training may be achieved. The results will be validated by future animal trials where the relationship between the level of support and pulmonary vascular pressure can be investigated in vivo. Further device design concerning foldable impeller leaflets will be carried out. At a final stage, the crimped version is supposed to reach a size below 1 cm to facilitate minimally invasive insertion. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Noise Reduction Through Circulation Control
NASA Technical Reports Server (NTRS)
Munro, Scott E.; Ahuja, K. K.; Englar, Robert J.
2005-01-01
Circulation control technology uses tangential blowing around a rounded trailing edge or a leading edge to change the force and moment characteristics of an aerodynamic body. This technology has been applied to circular cylinders, wings, helicopter rotors, and even to automobiles for improved aerodynamic performance. Only limited research has been conducted on the acoustic of this technology. Since wing flaps contribute to the environmental noise of an aircraft, an alternate blown high lift system without complex mechanical flaps could prove beneficial in reducing the noise of an approaching aircraft. Thus, in this study, a direct comparison of the acoustic characteristics of high lift systems employing a circulation control wing configuration and a conventional wing flapped configuration has been made. These results indicate that acoustically, a circulation control wing high lift system could be considerably more acceptable than a wing with conventional mechanical flaps.
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183513 (3 Nov. 2010) --- STS-135 crew members participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Pictured from the left are NASA astronauts Chris Ferguson, commander; Rex Walheim, mission specialist; Doug Hurley, pilot; and Sandy Magnus, mission specialist. John Ray (right) assisted the crew members. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183514 (3 Nov. 2010) --- STS-135 crew members participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Pictured from the left are NASA astronauts Chris Ferguson, commander; Rex Walheim, mission specialist; Doug Hurley, pilot; and Sandy Magnus, mission specialist. John Ray (right) assisted the crew members. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
STS-335 crew training, EVA TPS Overview with instructor John Ray
2010-11-03
JSC2010-E-183512 (3 Nov. 2010) --- STS-135 crew members participate in an EVA Thermal Protection System (TPS) overview training session in the TPS/ Precision Air Bearing Facility in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center. Pictured from the left are NASA astronauts Chris Ferguson, commander; Rex Walheim, mission specialist; Doug Hurley, pilot; and Sandy Magnus, mission specialist. John Ray (right) assisted the crew members. STS-135 is planned to be the final mission of the space shuttle program. Photo credit: NASA or National Aeronautics and Space Administration
Space Station Application of Simulator-Developed Aircrew Coordination and Performance Measures
NASA Technical Reports Server (NTRS)
Murphy, Miles
1985-01-01
This paper summarizes a study in progress at NASA/Ames Research Center to develop measures of aircrew coordination and decision-making factors and to relate them to flight task performance, that is, to crew and system performance measures. The existence of some similar interpersonal process and task performance requirements suggests a potential application of these methods in space station crew research -- particularly research conducted in ground-based mock-ups. The secondary objective of this study should also be of interest: to develop information on crew process and performance for application in developing crew training programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K.; Fowley, M.
A full-scale, transparent mock-up of the Hanford Tank Waste Treatment and Immobilization Project High Level Waste glass melter riser and pour spout has been constructed to allow for testing with visual feedback of particle settling, accumulation, and resuspension when operating with a controlled fraction of crystals in the glass melt. Room temperature operation with silicone oil and magnetite particles simulating molten glass and spinel crystals, respectively, allows for direct observation of flow patterns and settling patterns. The fluid and particle mixture is recycled within the system for each test.
In situ conversion process utilizing a closed loop heating system
Sandberg, Chester Ledlie [Palo Alto, CA; Fowler, Thomas David [Houston, TX; Vinegar, Harold J [Bellaire, TX; Schoeber, Willen Jan Antoon Henri
2009-08-18
An in situ conversion system for producing hydrocarbons from a subsurface formation is described. The system includes a plurality of u-shaped wellbores in the formation. Piping is positioned in at least two of the u-shaped wellbores. A fluid circulation system is coupled to the piping. The fluid circulation system is configured to circulate hot heat transfer fluid through at least a portion of the piping to form at least one heated portion of the formation. An electrical power supply is configured to provide electrical current to at least a portion of the piping located below an overburden in the formation to resistively heat at least a portion of the piping. Heat transfers from the piping to the formation.
Efficient quantum circuits for dense circulant and circulant like operators
Zhou, S. S.
2017-01-01
Circulant matrices are an important family of operators, which have a wide range of applications in science and engineering-related fields. They are, in general, non-sparse and non-unitary. In this paper, we present efficient quantum circuits to implement circulant operators using fewer resources and with lower complexity than existing methods. Moreover, our quantum circuits can be readily extended to the implementation of Toeplitz, Hankel and block circulant matrices. Efficient quantum algorithms to implement the inverses and products of circulant operators are also provided, and an example application in solving the equation of motion for cyclic systems is discussed. PMID:28572988
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training.
NASA Technical Reports Server (NTRS)
2004-01-01
KENNEDY SPACE CENTER, FLA. Emergency crew members return to the orbiter crew compartment mock-up that is the scene of a Mode VII emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts simulating various injuries inside the mock-up compartment. Rescuers have had to remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.
Religious characteristics and the death penalty.
Miller, Monica K; Hayward, R David
2008-04-01
Using one mock trial scenario, this study investigated whether religious and demographic factors were related to death penalty attitudes and sentencing verdicts. Those who favored the death penalty differed from those who had doubts about the penalty in gender, affiliation, fundamentalism, evangelism, literal Biblical interpretism, beliefs about God's attitudes toward murders, and perceptions of how their religious groups felt about the death penalty. These relationships generally held after mock jurors were death qualified. Gender, fundamentalism, literal interpretism, beliefs about God's death penalty position, and perceptions of how one's religious group felt about the death penalty predicted death penalty sentencing verdicts. Future research could determine whether using peremptory challenges to exclude potential jurors based on religion can help lawyers choose a more favorable jury.
Co-Production of Electricity and Hydrogen Using a Novel Iron-based Catalyst
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilaly, Ahmad; Georgas, Adam; Leboreiro, Jose
2011-09-30
The primary objective of this project was to develop a hydrogen production technology for gasification applications based on a circulating fluid-bed reactor and an attrition resistant iron catalyst. The work towards achieving this objective consisted of three key activities: Development of an iron-based catalyst suitable for a circulating fluid-bed reactor; Design, construction, and operation of a bench-scale circulating fluid-bed reactor system for hydrogen production; Techno-economic analysis of the steam-iron and the pressure swing adsorption hydrogen production processes. This report describes the work completed in each of these activities during this project. The catalyst development and testing program prepared and iron-basedmore » catalysts using different support and promoters to identify catalysts that had sufficient activity for cyclic reduction with syngas and steam oxidation and attrition resistance to enable use in a circulating fluid-bed reactor system. The best performing catalyst from this catalyst development program was produced by a commercial catalyst toll manufacturer to support the bench-scale testing activities. The reactor testing systems used during material development evaluated catalysts in a single fluid-bed reactor by cycling between reduction with syngas and oxidation with steam. The prototype SIP reactor system (PSRS) consisted of two circulating fluid-bed reactors with the iron catalyst being transferred between the two reactors. This design enabled demonstration of the technical feasibility of the combination of the circulating fluid-bed reactor system and the iron-based catalyst for commercial hydrogen production. The specific activities associated with this bench-scale circulating fluid-bed reactor systems that were completed in this project included design, construction, commissioning, and operation. The experimental portion of this project focused on technical demonstration of the performance of an iron-based catalyst and a circulating fluid-bed reactor system for hydrogen production. Although a technology can be technically feasible, successful commercial deployment also requires that a technology offer an economic advantage over existing commercial technologies. To effective estimate the economics of this steam-iron process, a techno-economic analysis of this steam iron process and a commercial pressure swing adsorption process were completed. The results from this analysis described in this report show the economic potential of the steam iron process for integration with a gasification plant for coproduction of hydrogen and electricity.« less
NASA Astrophysics Data System (ADS)
Scarlat, Raluca Olga
This dissertation treats system design, modeling of transient system response, and characterization of individual phenomena and demonstrates a framework for integration of these three activities early in the design process of a complex engineered system. A system analysis framework for prioritization of experiments, modeling, and development of detailed design is proposed. Two fundamental topics in thermal-hydraulics are discussed, which illustrate the integration of modeling and experimentation with nuclear reactor design and safety analysis: thermal-hydraulic modeling of heat generating pebble bed cores, and scaled experiments for natural circulation heat removal with Boussinesq liquids. The case studies used in this dissertation are derived from the design and safety analysis of a pebble bed fluoride salt cooled high temperature nuclear reactor (PB-FHR), currently under development in the United States at the university and national laboratories level. In the context of the phenomena identification and ranking table (PIRT) methodology, new tools and approaches are proposed and demonstrated here, which are specifically relevant to technology in the early stages of development, and to analysis of passive safety features. A system decomposition approach is proposed. Definition of system functional requirements complements identification and compilation of the current knowledge base for the behavior of the system. Two new graphical tools are developed for ranking of phenomena importance: a phenomena ranking map, and a phenomena identification and ranking matrix (PIRM). The functional requirements established through this methodology were used for the design and optimization of the reactor core, and for the transient analysis and design of the passive natural circulation driven decay heat removal system for the PB-FHR. A numerical modeling approach for heat-generating porous media, with multi-dimensional fluid flow is presented. The application of this modeling approach to the PB-FHR annular pebble bed core cooled by fluoride salt mixtures generated a model that is called Pod. Pod. was used to show the resilience of the PB-FHR core to generation of hot spots or cold spots, due to the effect of buoyancy on the flow and temperature distribution in the packed bed. Pod. was used to investigate the PB-FHR response to ATWS transients. Based on the functional requirements for the core, Pod. was used to generate an optimized design of the flow distribution in the core. An analysis of natural circulation loops cooled by single-phase Boussinesq fluids is presented here, in the context of reactor design that relies on natural circulation decay heat removal, and design of scaled experiments. The scaling arguments are established for a transient natural circulation loop, for loops that have long fluid residence time, and negligible contribution of fluid inertia to the momentum equation. The design of integral effects tests for the loss of forced circulation (LOFC) for PB-FHR is discussed. The special case of natural circulation decay heat removal from a pebble bed reactor was analyzed. A way to define the Reynolds number in a multi-dimensional pebble bed was identified. The scaling methodology for replicating pebble bed friction losses using an electrically resistance heated annular pipe and a needle valve was developed. The thermophysical properties of liquid fluoride salts lead to design of systems with low flow velocities, and hence long fluid residence times. A comparison among liquid coolants for the performance of steady state natural circulation heat removal from a pebble bed was performed. Transient natural circulation experimental data with simulant fluids for fluoride salts is given here. The low flow velocity and the relatively high viscosity of the fluoride salts lead to low Reynolds number flows, and a low Reynolds number in conjunction with a sufficiently high coefficient of thermal expansion makes the system susceptible to local buoyancy effects Experiments indicate that slow exchange of stagnant fluid in static legs can play a significant role in the transient response of natural circulation loops. The effect of non-linear temperature profiles on the hot or cold legs or other segments of the flow loop, which may develop during transient scenarios, should be considered when modeling the performance of natural circulation loops. The data provided here can be used for validation of the application of thermal-hydraulic systems codes to the modeling of heat removal by natural circulation with liquid fluoride salts and its simulant fluids.
A Forecast Skill Comparison between CliPAS One-Tier and Two-Tier Hindcast Experiments
NASA Astrophysics Data System (ADS)
Lee, J.; Wang, B.; Kang, I.
2006-05-01
A 24-year (1981-2004) MME hindcast experimental dataset is produced under the "Climate Prediction and Its Application to Society" (CliPAS) project sponsored by Korean Meteorological Administration (KMA). This dataset consists of 5 one-tier model systems from National Aeronautics and Space Administration (NASA), National Center for Environmental Prediction (NCEP), Frontier Research Center for Global Change (FRCGC), Seoul National University (SNU), and University of Hawaii (UH) and 5 two-tier model systems from Florida State University (FSU), Geophysical Fluid Dynamic Lab (GFDL), SNU, and UH. Multi-model Ensemble (MME) Forecast skills of seasonal precipitation and atmospheric circulation are compared between CliPAS one-tier and two-tier hindcast experiments for seasonal mean precipitation and atmospheric circulation. For winter prediction, two-tier MME has a comparable skill to one-tier MME. However, it is demonstrated that in the Asian-Australian monsoon (A-AM) heavy precipitation regions, one-tier systems are superior to two-tier systems in summer season. The reason is that inclusion of the local warm pool- monsoon interaction in the one-tier system improves the ENSO teleconnection with monsoon regions. Both one-tier and two-tier MME fail to predict Indian monsoon circulation, while they have a significantly good skill for the broad scale monsoon circulation defined by Webster and Yang index. One-tier system has a much better skill to predict the monsoon circulation over the western North pacific where air-sea interaction plays an important role than two-tier system.
Boermeester, M. A.; Houdijk, A. P.; Meyer, S.; Cuesta, M. A.; Appelmelk, B. J.; Wesdorp, R. I.; Hack, C. E.; Van Leeuwen, P. A.
1995-01-01
The observed increased susceptibility of patients with fulminant hepatic failure for local and systemic infections has been hypothesized to be due to a failure for the hepatic clearance function and subsequent leaking of endogenous endotoxins into the systemic circulation. However, experimental evidence for such a systemic inflammation during liver failure due to endogenous endotoxemia is lacking. Therefore, we designed a study to clarify whether circulating endotoxins due to liver failure could lead to the development of systemic inflammations. In a rat model for liver failure induced by a two-thirds partial hepatectomy, we evaluated the course of circulating tumor necrosis factor and interleukin-6, changes in blood chemistry and hemodynamics, and histopathological changes in the lungs. Partially hepatectomized animals, but not sham-operated animals, demonstrated cardiac failure, increased levels of creatinin and urea, metabolic acidosis, high plasma levels of tumor necrosis factor and interleukin-6, and an influx of PMNs in the lungs-together indicating the development of a systemic inflammatory response. Continuous infusion of recombinant N-terminal bactericidal/permeability-increasing protein (rBPI23), a well described endotoxin-neutralizing protein, prevented these inflammatory reactions. Ex vivo experiments with rat plasma samples confirmed the presence of circulating endotoxins in partially hepatectomized rats as opposed to those treated with rBPI23. Thus, our results indicate that the early phase of liver failure induces a systemic inflammatory response triggered by circulating endotoxins, which can be prevented by perioperative infusion of rBPI23. Images Figure 2 PMID:7485405
Miniature Gas-Circulating Machine
NASA Technical Reports Server (NTRS)
Swift, Walter L.; Valenzuela, Javier A.; Sixsmith, Herbert; Nutt, William E.
1993-01-01
Proposed gas-circulating machine consists essentially of centrifugal pump driven by induction motor. Noncontact bearings suppress wear and contamination. Used to circulate helium (or possibly hydrogen or another gas) in regeneration sorption-compressor refrigeration system aboard spacecraft. Also proves useful in terrestrial applications in which long life, reliability, and low contamination essential.
76 FR 12217 - Exempt Discretionary Program Grants (Section 5309) for Urban Circulator Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-04
... redevelopment of urban spaces into walkable mixed use, high density environments. FOR FURTHER INFORMATION... development. FTA's approval to advance the Urban Circulator projects through project development and grant... urban circulators shall be required to submit information that describes the impact of the urban...
NASA Astrophysics Data System (ADS)
Yang, Ping; Liu, Rongrong; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Wei, Xunbin
2015-03-01
Melanoma is a malignant tumor of melanocytes. Circulating melanoma cell has high light absorption due to melanin highly contained in melanoma cells. This property is employed for the detection of circulating melanoma cell by in vivo photoacoustic flow cytometry (PAFC). PAFC is based on photoacoustic effect. Compared to in vivo flow cytometry based on fluorescence, PAFC can employ high melanin content of melanoma cells as endogenous biomarkers to detect circulating melanoma cells in vivo. In our research, we developed in vitro experiments to prove the ability of PAFC system of detecting PA signals from melanoma cells. For in vivo experiments, we constructed a model of melanoma tumor bearing mice by inoculating highly metastatic murine melanoma cancer cells B16F10 with subcutaneous injection. PA signals were detected in the blood vessels of mouse ears in vivo. By counting circulating melanoma cells termly, we obtained the number variation of circulating melanoma cells as melanoma metastasized. Those results show that PAFC is a noninvasive and label-free method to detect melanoma metastases in blood or lymph circulation. Our PAFC system is an efficient tool to monitor melanoma metastases, cancer recurrence and therapeutic efficacy.
29 CFR 1910.126 - Additional requirements for special dipping and coating operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sprinklers; or (ii) An automatic fire-extinguishing system conforming to the requirements of subpart L of... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...