Sample records for model linking mini

  1. Nonlinear Modeling of Joint Dominated Structures

    NASA Technical Reports Server (NTRS)

    Chapman, J. M.

    1990-01-01

    The development and verification of an accurate structural model of the nonlinear joint-dominated NASA Langley Mini-Mast truss are described. The approach is to characterize the structural behavior of the Mini-Mast joints and struts using a test configuration that can directly measure the struts' overall stiffness and damping properties, incorporate this data into the structural model using the residual force technique, and then compare the predicted response with empirical data taken by NASA/LaRC during the modal survey tests of the Mini-Mast. A new testing technique, referred to as 'link' testing, was developed and used to test prototype struts of the Mini-Masts. Appreciable nonlinearities including the free-play and hysteresis were demonstrated. Since static and dynamic tests performed on the Mini-Mast also exhibited behavior consistent with joints having free-play and hysteresis, nonlinear models of the Mini-Mast were constructed and analyzed. The Residual Force Technique was used to analyze the nonlinear model of the Mini-Mast having joint free-play and hysteresis.

  2. Controller Evaluation of Initial Data Link Air Traffic Control Services, Mini Study 1, Volume 2

    DOT National Transportation Integrated Search

    1988-09-01

    This report details the results of Mini Study 1. This mini study was conducted : at the Federal Aviation Administration (FAA) Technical Center utilizing the Data : Link testbed. Initial Data Link air traffic control services were evaluated : under pa...

  3. Controller Evaluation of Initial Data Link Air Traffic Control Services: Mini Study 2 Volume II

    DOT National Transportation Integrated Search

    1989-03-01

    This report details the results of Mini Study 2. This Mini Study was conducted at the Federal Aviation Administration (FAA) Technical Center utilizing the Data Link test bed. Initial Data Link air traffic control services were evaluated under part ta...

  4. Controller Evaluation of Initial Data Link Air Traffic Control Services: Mini Study 2 Volume I

    DOT National Transportation Integrated Search

    1989-03-01

    This report details the results of Mini Study 2. This Mini Study was conducted at the Federal Aviation Administration (FAA) Technical Center utilizing the Data Link test bed. Initial Data Link air traffic control services were evaluated under part ta...

  5. Controller Evaluation of Initial Data Link Air Traffic Control Services, Mini Study 1, Volume 1

    DOT National Transportation Integrated Search

    1988-09-01

    This report details the results of Mini Study 1. This mini study was conducted : at the Federal Aviation (FAA) Technical Center utilizing the Data Link testbed. : Initial Data Link air traffic control services were under part task simulation : condit...

  6. Critical Structural and Functional Roles for the N-Terminal Insertion Sequence in Surfactant Protein B Analogs

    PubMed Central

    Walther, Frans J.; Waring, Alan J.; Hernandez-Juviel, Jose M.; Gordon, Larry M.; Wang, Zhengdong; Jung, Chun-Ling; Ruchala, Piotr; Clark, Andrew P.; Smith, Wesley M.; Sharma, Shantanu; Notter, Robert H.

    2010-01-01

    Background Surfactant protein B (SP-B; 79 residues) belongs to the saposin protein superfamily, and plays functional roles in lung surfactant. The disulfide cross-linked, N- and C-terminal domains of SP-B have been theoretically predicted to fold as charged, amphipathic helices, suggesting their participation in surfactant activities. Earlier structural studies with Mini-B, a disulfide-linked construct based on the N- and C-terminal regions of SP-B (i.e., ∼residues 8–25 and 63–78), confirmed that these neighboring domains are helical; moreover, Mini-B retains critical in vitro and in vivo surfactant functions of the native protein. Here, we perform similar analyses on a Super Mini-B construct that has native SP-B residues (1–7) attached to the N-terminus of Mini-B, to test whether the N-terminal sequence is also involved in surfactant activity. Methodology/Results FTIR spectra of Mini-B and Super Mini-B in either lipids or lipid-mimics indicated that these peptides share similar conformations, with primary α-helix and secondary β-sheet and loop-turns. Gel electrophoresis demonstrated that Super Mini-B was dimeric in SDS detergent-polyacrylamide, while Mini-B was monomeric. Surface plasmon resonance (SPR), predictive aggregation algorithms, and molecular dynamics (MD) and docking simulations further suggested a preliminary model for dimeric Super Mini-B, in which monomers self-associate to form a dimer peptide with a “saposin-like” fold. Similar to native SP-B, both Mini-B and Super Mini-B exhibit in vitro activity with spread films showing near-zero minimum surface tension during cycling using captive bubble surfactometry. In vivo, Super Mini-B demonstrates oxygenation and dynamic compliance that are greater than Mini-B and compare favorably to full-length SP-B. Conclusion Super Mini-B shows enhanced surfactant activity, probably due to the self-assembly of monomer peptide into dimer Super Mini-B that mimics the functions and putative structure of native SP-B. PMID:20084172

  7. Controller Evaluation of Initial Data Link Terminal Air Traffic Control Services: Mini Study 2, Volume 1

    DOT National Transportation Integrated Search

    1992-04-01

    This document details the results of the second Mini Study of the Federal : Aviation Administration (FAA)Technical Center investigation and development of : initial terminal air traffic control (ATC) services for transmission using Data : Link techno...

  8. Development of a human rotavirus induced diarrhea model in Chinese mini-pigs.

    PubMed

    Li, Jin-Tao; Wei, Jing; Guo, Hong-Xia; Han, Jiang-Bo; Ye, Nan; He, Hai-Yang; Yu, Tian-Tian; Wu, Yu-Zhang

    2016-08-21

    To establish a new animal model for the research of human rotavirus (HRV) infection, its pathogenesis and immunity and evaluation of potential vaccines. 5-d, 30-d and 60-d-old Chinese mini-pigs, Guizhou and Bamma, were inoculated with a single oral dose of attenuated strain Wa, G1, G3 of HRV, and PBS (control), respectively, and fecal samples of pigs from 0 to 7 d post infection (DPI) were collected individually. Enzyme linked immunosorbent assay was used to detect HRV antigen in feces. The HRV was tested by real-time PCR (RT-PCR). The sections of the intestinal tissue were stained with hematoxylin and eosin to observe the morphologic variation by microscopy. Immunofluorescence was used to determine the HRV in intestinal tissue. HRV particles in cells of the ileum were observed by electron micrography. When inoculated with HRV, mini-pigs younger than 30 d developed diarrhea in an age-dependent manner and shed HRV antigen of the same inoculum, as demonstrated by RT-PCR. Histopathological changes were observed in HRV inoculated mini-pigs including small intestinal cell tumefaction and necrosis. HRV that was distributed in the small intestine was restricted to the top part of the villi on the internal wall of the ileum, which was observed by immunofluorescence and transmission electron microscopy. Virus particles were observed in Golgi like follicles in HRV-infected neonatal mini-pigs. Guizhou mini-pigs were more sensitive to HRV than Bamma with respect to RV antigen shedding and clinical diarrhea. These results indicate that we have established a mini-pig model of HRV induced diarrhea. Our findings are useful for the understanding of the pathogenic mechanisms of HRV infection.

  9. Use of non-parametric item response theory to develop a shortened version of the Positive and Negative Syndrome Scale (PANSS).

    PubMed

    Khan, Anzalee; Lewis, Charles; Lindenmayer, Jean-Pierre

    2011-11-16

    Nonparametric item response theory (IRT) was used to examine (a) the performance of the 30 Positive and Negative Syndrome Scale (PANSS) items and their options ((levels of severity), (b) the effectiveness of various subscales to discriminate among differences in symptom severity, and (c) the development of an abbreviated PANSS (Mini-PANSS) based on IRT and a method to link scores to the original PANSS. Baseline PANSS scores from 7,187 patients with Schizophrenia or Schizoaffective disorder who were enrolled between 1995 and 2005 in psychopharmacology trials were obtained. Option characteristic curves (OCCs) and Item Characteristic Curves (ICCs) were constructed to examine the probability of rating each of seven options within each of 30 PANSS items as a function of subscale severity, and summed-score linking was applied to items selected for the Mini-PANSS. The majority of items forming the Positive and Negative subscales (i.e. 19 items) performed very well and discriminate better along symptom severity compared to the General Psychopathology subscale. Six of the seven Positive Symptom items, six of the seven Negative Symptom items, and seven out of the 16 General Psychopathology items were retained for inclusion in the Mini-PANSS. Summed score linking and linear interpolation was able to produce a translation table for comparing total subscale scores of the Mini-PANSS to total subscale scores on the original PANSS. Results show scores on the subscales of the Mini-PANSS can be linked to scores on the original PANSS subscales, with very little bias. The study demonstrated the utility of non-parametric IRT in examining the item properties of the PANSS and to allow selection of items for an abbreviated PANSS scale. The comparisons between the 30-item PANSS and the Mini-PANSS revealed that the shorter version is comparable to the 30-item PANSS, but when applying IRT, the Mini-PANSS is also a good indicator of illness severity.

  10. Use of NON-PARAMETRIC Item Response Theory to develop a shortened version of the Positive and Negative Syndrome Scale (PANSS)

    PubMed Central

    2011-01-01

    Background Nonparametric item response theory (IRT) was used to examine (a) the performance of the 30 Positive and Negative Syndrome Scale (PANSS) items and their options ((levels of severity), (b) the effectiveness of various subscales to discriminate among differences in symptom severity, and (c) the development of an abbreviated PANSS (Mini-PANSS) based on IRT and a method to link scores to the original PANSS. Methods Baseline PANSS scores from 7,187 patients with Schizophrenia or Schizoaffective disorder who were enrolled between 1995 and 2005 in psychopharmacology trials were obtained. Option characteristic curves (OCCs) and Item Characteristic Curves (ICCs) were constructed to examine the probability of rating each of seven options within each of 30 PANSS items as a function of subscale severity, and summed-score linking was applied to items selected for the Mini-PANSS. Results The majority of items forming the Positive and Negative subscales (i.e. 19 items) performed very well and discriminate better along symptom severity compared to the General Psychopathology subscale. Six of the seven Positive Symptom items, six of the seven Negative Symptom items, and seven out of the 16 General Psychopathology items were retained for inclusion in the Mini-PANSS. Summed score linking and linear interpolation was able to produce a translation table for comparing total subscale scores of the Mini-PANSS to total subscale scores on the original PANSS. Results show scores on the subscales of the Mini-PANSS can be linked to scores on the original PANSS subscales, with very little bias. Conclusions The study demonstrated the utility of non-parametric IRT in examining the item properties of the PANSS and to allow selection of items for an abbreviated PANSS scale. The comparisons between the 30-item PANSS and the Mini-PANSS revealed that the shorter version is comparable to the 30-item PANSS, but when applying IRT, the Mini-PANSS is also a good indicator of illness severity. PMID:22087503

  11. Mini-Tn7 Insertion in Bacteria With Multiple glmS-Linked attTn7 Sites: Example Burkholderia Mallei ATCC 23344

    DTIC Science & Technology

    2006-06-27

    INTRODUCTION Burkholderia mallei is the etiological agent of glanders and a highly evolved obligate zoonotic mammalian pathogen that naturally affects horses...mini-Tn7 insertion in bacteria with multiple glmS-linked attTn7 sites: example Burkholderia mallei ATCC 23344 Kyoung-Hee Choi1, David DeShazer2... glanders is a rare disease, B. mallei has received renewed attention because of its listing as a category B agent by the Centers for Disease Control

  12. MiniX-STR multiplex system population study in Japan and application to degraded DNA analysis.

    PubMed

    Asamura, H; Sakai, H; Kobayashi, K; Ota, M; Fukushima, H

    2006-05-01

    We sought to evaluate a more effective system for analyzing X-chromosomal short tandem repeats (X-STRs) in highly degraded DNA. To generate smaller amplicon lengths, we designed new polymerase chain reaction (PCR) primers for DXS7423, DXS6789, DXS101, GATA31E08, DXS8378, DXS7133, DXS7424, and GATA165B12 at X-linked short tandem repeat (STR) loci, devising two miniX-multiplex PCR systems. Among 333 Japanese individuals, these X-linked loci were detected in amplification products ranging in length from 76 to 169 bp, and statistical analyses of the eight loci indicated a high usefulness for the Japanese forensic practice. Results of tests on highly degraded DNA indicated the miniX-STR multiplex strategies to be an effective system for analyzing degraded DNA. We conclude that analysis by the current miniX-STR multiplex systems offers high effectiveness for personal identification from degraded DNA samples.

  13. [Bone remodeling and modeling/mini-modeling.

    PubMed

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  14. Quasi-periodic Behavior of Mini-disks in Binary Black Holes Approaching Merger

    NASA Astrophysics Data System (ADS)

    Bowen, Dennis B.; Mewes, Vassilios; Campanelli, Manuela; Noble, Scott C.; Krolik, Julian H.; Zilhão, Miguel

    2018-01-01

    We present the first magnetohydrodynamic simulation in which a circumbinary disk around a relativistic binary black hole feeds mass to individual accretion disks (“mini-disks”) around each black hole. Mass flow through the accretion streams linking the circumbinary disk to the mini-disks is modulated quasi-periodically by the streams’ interaction with a nonlinear m = 1 density feature, or “lump,” at the inner edge of the circumbinary disk: the stream supplying each mini-disk comes into phase with the lump at a frequency 0.74 times the binary orbital frequency. Because the binary is relativistic, the tidal truncation radii of the mini-disks are not much larger than their innermost stable circular orbits; consequently, the mini-disks’ inflow times are shorter than the conventional estimate and are comparable to the stream modulation period. As a result, the mini-disks are always in inflow disequilibrium, with their masses and spiral density wave structures responding to the stream’s quasi-periodic modulation. The fluctuations in each mini-disk’s mass are so large that as much as 75% of the total mini-disk mass can be contained within a single mini-disk. Such quasi-periodic modulation of the mini-disk structure may introduce distinctive time-dependent features in the binary’s electromagnetic emission.

  15. Linking the open source, spatial electrification tool (ONSSET) and the open source energy modelling system (OSeMOSYS), with a focus on Sub-Saharan Africa

    NASA Astrophysics Data System (ADS)

    Mentis, Dimitrios; Howells, Mark; Rogner, Holger; Korkovelos, Alexandros; Arderne, Christopher; Siyal, Shahid; Zepeda, Eduardo; Taliotis, Constantinos; Bazilian, Morgan; de Roo, Ad; Tanvez, Yann; Oudalov, Alexandre; Scholtz, Ernst

    2017-04-01

    In September 2015, the United Nations General Assembly adopted Agenda 2030, which comprises a set of 17 Sustainable Development Goals (SDGs) defined by 169 targets. "Ensuring access to affordable, reliable, sustainable and modern energy for all by 2030" is the seventh goal (SDG7). While access to energy refers to more than electricity, the latter is the central focus of this work. According to the World Bank's 2015 Global Tracking Framework, roughly 15% of world population (or 1.1 billion people) lack access to electricity, and many more rely on poor quality electricity services. The majority of those without access (87%) reside in rural areas. This paper presents results of a Geographic Information Systems (GIS) approach coupled with open access data and linked to the Electricity Model Base for Africa (TEMBA), a model that represents each continental African country's electricity supply system. We present least-cost electrification strategies on a country-by-country basis for Sub-Saharan Africa. The electrification options include grid extension, mini-grid and stand-alone systems for rural, peri-urban, and urban contexts across the economy. At low levels of electricity demand there is a strong penetration of standalone technologies. However, higher electricity demand levels move the favourable electrification option from stand-alone systems to mini grid and to grid extensions.

  16. Web-based software tool for constraint-based design specification of synthetic biological systems.

    PubMed

    Oberortner, Ernst; Densmore, Douglas

    2015-06-19

    miniEugene provides computational support for solving combinatorial design problems, enabling users to specify and enumerate designs for novel biological systems based on sets of biological constraints. This technical note presents a brief tutorial for biologists and software engineers in the field of synthetic biology on how to use miniEugene. After reading this technical note, users should know which biological constraints are available in miniEugene, understand the syntax and semantics of these constraints, and be able to follow a step-by-step guide to specify the design of a classical synthetic biological system-the genetic toggle switch.1 We also provide links and references to more information on the miniEugene web application and the integration of the miniEugene software library into sophisticated Computer-Aided Design (CAD) tools for synthetic biology ( www.eugenecad.org ).

  17. Development and validation of a multiplex reaction analyzing eight miniSTRs of the X chromosome for identity and kinship testing with degraded DNA.

    PubMed

    Castañeda, María; Odriozola, Adrián; Gómez, Javier; Zarrabeitia, María T

    2013-07-01

    We report the development of an effective system for analyzing X chromosome-linked mini short tandem repeat loci with reduced-size amplicons (less than 220 bp), useful for analyzing highly degraded DNA samples. To generate smaller amplicons, we redesigned primers for eight X-linked microsatellites (DXS7132, DXS10079, DXS10074, DXS10075, DXS6801, DXS6809, DXS6789, and DXS6799) and established efficient conditions for a multiplex PCR system (miniX). The validation tests confirmed that it has good sensitivity, requiring as little as 20 pg of DNA, and performs well with DNA from paraffin-embedded tissues, thus showing potential for improved analysis and identification of highly degraded and/or very limited DNA samples. Consequently, this system may help to solve complex forensic cases, particularly when autosomal markers convey insufficient information.

  18. A Mini-Library of Sequenced Human DNA Fragments: Linking Bench Experiments with Informatics

    ERIC Educational Resources Information Center

    Dalgleish, Raymond; Shanks, Morag E.; Monger, Karen; Butler, Nicola J.

    2012-01-01

    We describe the development of a mini-library of human DNA fragments for use in an enquiry-based learning (EBL) undergraduate practical incorporating "wet-lab" and bioinformatics tasks. In spite of the widespread emergence of the polymerase chain reaction (PCR), the cloning and analysis of DNA fragments in "Escherichia coli"…

  19. Ortho-Rectification of Narrow Band Multi-Spectral Imagery Assisted by Dslr RGB Imagery Acquired by a Fixed-Wing Uas

    NASA Astrophysics Data System (ADS)

    Rau, J.-Y.; Jhan, J.-P.; Huang, C.-Y.

    2015-08-01

    Miniature Multiple Camera Array (MiniMCA-12) is a frame-based multilens/multispectral sensor composed of 12 lenses with narrow band filters. Due to its small size and light weight, it is suitable to mount on an Unmanned Aerial System (UAS) for acquiring high spectral, spatial and temporal resolution imagery used in various remote sensing applications. However, due to its wavelength range is only 10 nm that results in low image resolution and signal-to-noise ratio which are not suitable for image matching and digital surface model (DSM) generation. In the meantime, the spectral correlation among all 12 bands of MiniMCA images are low, it is difficult to perform tie-point matching and aerial triangulation at the same time. In this study, we thus propose the use of a DSLR camera to assist automatic aerial triangulation of MiniMCA-12 imagery and to produce higher spatial resolution DSM for MiniMCA12 ortho-image generation. Depending on the maximum payload weight of the used UAS, these two kinds of sensors could be collected at the same time or individually. In this study, we adopt a fixed-wing UAS to carry a Canon EOS 5D Mark2 DSLR camera and a MiniMCA-12 multi-spectral camera. For the purpose to perform automatic aerial triangulation between a DSLR camera and the MiniMCA-12, we choose one master band from MiniMCA-12 whose spectral range has overlap with the DSLR camera. However, all lenses of MiniMCA-12 have different perspective centers and viewing angles, the original 12 channels have significant band misregistration effect. Thus, the first issue encountered is to reduce the band misregistration effect. Due to all 12 MiniMCA lenses being frame-based, their spatial offsets are smaller than 15 cm and all images are almost 98% overlapped, we thus propose a modified projective transformation (MPT) method together with two systematic error correction procedures to register all 12 bands of imagery on the same image space. It means that those 12 bands of images acquired at the same exposure time will have same interior orientation parameters (IOPs) and exterior orientation parameters (EOPs) after band-to-band registration (BBR). Thus, in the aerial triangulation stage, the master band of MiniMCA-12 was treated as a reference channel to link with DSLR RGB images. It means, all reference images from the master band of MiniMCA-12 and all RGB images were triangulated at the same time with same coordinate system of ground control points (GCP). Due to the spatial resolution of RGB images is higher than the MiniMCA-12, the GCP can be marked on the RGB images only even they cannot be recognized on the MiniMCA images. Furthermore, a one meter gridded digital surface model (DSM) is created by the RGB images and applied to the MiniMCA imagery for ortho-rectification. Quantitative error analyses show that the proposed BBR scheme can achieve 0.33 pixels of average misregistration residuals length and the co-registration errors among 12 MiniMCA ortho-images and between MiniMCA and Canon RGB ortho-images are all less than 0.6 pixels. The experimental results demonstrate that the proposed method is robust, reliable and accurate for future remote sensing applications.

  20. Effects of monocortical and bicortical mini-implant anchorage on bone-borne palatal expansion using finite element analysis.

    PubMed

    Lee, Robert J; Moon, Won; Hong, Christine

    2017-05-01

    Bone-borne palatal expansion relies on mini-implant stability for successful orthopedic expansion. The large magnitude of applied force experienced by mini-implants during bone-borne expansion may lead to high failure rates. Use of bicortical mini-implant anchorage rather than monocortical anchorage may improve mini-implant stability. The aims of this study were to analyze and compare the effects of bicortical and monocortical anchorages on stress distribution and displacement during bone-borne palatal expansion using finite element analysis. Two skull models were constructed to represent expansion before and after midpalatal suture opening. Three clinical situations with varying mini-implant insertion depths were studied in each skull model: monocortical, 1-mm bicortical, and 2.5-mm bicortical. Finite element analysis simulations were performed for each clinical situation in both skull models. Von Mises stress distribution and transverse displacement were evaluated for all models. Peri-implant stress was greater in the monocortical anchorage model compared with both bicortical anchorage models. In addition, transverse displacement was greater and more parallel in the coronal plane for both bicortical models compared with the monocortical model. Minimal differences were observed between the 1-mm and the 2.5-mm bicortical models for both peri-implant stress and transverse displacement. Bicortical mini-implant anchorage results in improved mini-implant stability, decreased mini-implant deformation and fracture, more parallel expansion in the coronal plane, and increased expansion during bone-borne palatal expansion. However, the depth of bicortical mini-implant anchorage was not significant. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Effects of monocortical and bicortical mini-implant anchorage on bone-borne palatal expansion using finite element analysis

    PubMed Central

    Lee, Robert J.; Moon, Won; Hong, Christine

    2017-01-01

    Introduction Bone-borne palatal expansion relies on mini-implant stability for successful orthopedic expansion. The large magnitude of applied force experienced by mini-implants during bone-borne expansion may lead to high failure rates. Use of bicortical mini-implant anchorage rather than monocortical anchorage may improve mini-implant stability. The aim of this study was to analyze and compare the effects of bicortical and monocortical anchorage on stress distribution and displacement during bone-borne palatal expansion using finite element analysis (FEA). Methods Two skull models were constructed to represent expansion prior to and after midpalatal suture opening. Three clinical situations with varying mini-implant insertion depths were studied in each skull model: monocortical, 1mm bicortical, and 2.5mm bicortical. FEA simulations were performed for each clinical situation in both skull models. Von Mises stress distribution and transverse displacement was evaluated for all models. Results Peri-implant stress was greater in the monocortical anchorage model compared to both bicortical anchorage models. In addition, transverse displacement was greater and more parallel in the coronal plane for both bicortical models compared to the monocortical model. Minimal differences were observed between the 1mm bicortical and 2.5mm bicortical models for both peri-implant stress and transverse displacement. Conclusions Bicortical mini-implant anchorage results in improved mini-implant stability, decreased mini-implant deformation and fracture, more parallel expansion in the coronal plane, and increased expansion during bone-borne palatal expansion. However, the depth of bicortical mini-implant anchorage was not significant. PMID:28457266

  2. NREL: International Activities - Country Programs

    Science.gov Websites

    for use of mini-grid quality assurance and design standards and advising on mini-grid business models communities of practice and technical collaboration across countries on mini-grid development, modeling and interconnection standards and procedures, and with strengthening mini-grids and energy access programs. NREL is

  3. Quality Assurance Framework for Mini-Grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baring-Gould, Ian; Burman, Kari; Singh, Mohit

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Qualitymore » Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that will drive investment and scale-up in this sector. The QAF implementation process also defines a set of implementation guidelines that help the deployment of mini-grids on a regional or national scale, helping to insure successful rapid deployment of these relatively new remote energy options. Note that the QAF is technology agnostic, addressing both alternating current (AC) and direct current (DC) mini-grids, and is also applicable to renewable, fossil-fuel, and hybrid systems.« less

  4. Mini-CME eruptions in a flux emergence event in a coronal hole environment

    NASA Astrophysics Data System (ADS)

    Galsgaard, K.; Moreno-Insertis, F.

    2016-10-01

    Small scale jets are observed to take place at the interface between the open magnetic field in coronal holes and bipolar magnetic field concentrations. A fraction of these shows an eruptive behavior, where a combination of cold dense and hot light plasma has been observed to propagate out along the jet region, combining traditional jets with what looks like the eruption of mini-CMEs. Here we discuss a simple model scenario for the explosive energy release process that leads to a mixture of hot and cold plasma being accelerated upwards simultaneously. The model explains both the typical steady state inverted-Y jet and the subsequent mini-CME eruptions found in blowout jets. The numerical experiment consists of a buoyant unstable flux rope that emerges into an overlying slanted coronal field, thereby creating a bipolar magnetic field distribution in the photosphere with coronal loops linking the polarities. Reconnection between the emerged and preexisting magnetic systems including the launching of a classical inverted-Y jet. The experiment shows that this simple model provides for a very complicated dynamical behavior in its late phases. Five independent mini-CME eruptions follow the initial near steady-state jet phase. The first one is a direct consequence of the reconnection of the emerged magnetic flux, is mediated by the formation of a strongly sheared arcade followed by a tether-cutting reconnection process, and leads to the eruption of a twisted flux rope. The final four explosive eruptions, instead, are preceded by the formation of a twisted torus-like flux rope near the strong magnetic concentrations at the photosphere. As the tube center starts emerging an internal current sheet is formed below it. This sheet experiences a tether cutting process that provides the important upwards kick of the newly formed mini-CME structure. As the fast rising cold and dense tube interacts with the overlying magnetic field, it reconnects at different spatial locations, either through a null region or through a local strong shear region without nulls. The restructuring of the magnetic field lines generate magneto-acoustic waves that transport twist and cold plasma out along the less stressed parts of the newly reconnected field lines. The emphasis of the talk will be on the physical forces responsible for the initial flux tube rising and the effects and reasons for the following destruction of the mini-CMEs.

  5. Intra-vitreal αB crystallin fused to elastin-like polypeptide provides neuroprotection in a mouse model of age-related macular degeneration.

    PubMed

    Sreekumar, Parameswaran G; Li, Zhe; Wang, Wan; Spee, Christine; Hinton, David R; Kannan, Ram; MacKay, J Andrew

    2018-05-18

    Age-related macular degeneration (AMD) is the leading cause of severe and irreversible central vision loss, and the primary site of AMD pathology is the retinal pigment epithelium (RPE). Geographic atrophy (GA) is an advanced form of AMD characterized by extensive RPE cell loss, subsequent degeneration of photoreceptors, and thinning of retina. This report describes the protective potential of a peptide derived from the αB crystallin protein using a sodium iodate (NaIO 3 ) induced mouse model of GA. Systemic NaIO 3 challenge causes degeneration of the RPE and neighboring photoreceptors, which have similarities to retinas of GA patients. αB crystallin is an abundant ocular protein that maintains ocular clarity and retinal homeostasis, and a small peptide from this protein (mini cry) displays neuroprotective properties. To retain this peptide for longer in the vitreous, mini cry was fused to an elastin-like polypeptide (ELP). A single intra-vitreal treatment by this crySI fusion significantly inhibits retinal degeneration in comparison to free mini cry. While mini cry is cleared from the eye with a mean residence time of 0.4 days, crySI is retained with a mean residence time of 3.0 days; furthermore, fundus photography reveals evidence of retention at two weeks. Unlike the free mini cry, crySI protects the RPE against NaIO 3 challenge for at least two weeks after administration. CrySI also inhibits RPE apoptosis and caspase-3 activation and protects the retina from cell death up to 1-month post NaIO 3 challenge. These results show that intra-ocular ELP-linked peptides such as crySI hold promise as protective agents to prevent RPE atrophy and progressive retinal degeneration in AMD. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Controller evaluation of initial terminal data link ATC services : mini study 3 : final report

    DOT National Transportation Integrated Search

    1992-12-01

    This report documents the third Federal Aviation Administration (FAA) controller : evaluation of an initial group of four terminal air traffic control (ATC) : services and functions which are under development for implementation on a Data : Link air-...

  7. The October 2014 United States Treasury bond flash crash and the contributory effect of mini flash crashes

    PubMed Central

    Levine, Zachary S.; Floridi, Luciano

    2017-01-01

    We investigate the causal uncertainty surrounding the flash crash in the U.S. Treasury bond market on October 15, 2014, and the unresolved concern that no clear link has been identified between the start of the flash crash at 9:33 and the opening of the U.S. equity market at 9:30. We consider the contributory effect of mini flash crashes in equity markets, and find that the number of equity mini flash crashes in the three-minute window between market open and the Treasury Flash Crash was 2.6 times larger than the number experienced in any other three-minute window in the prior ten weekdays. We argue that (a) this statistically significant finding suggests that mini flash crashes in equity markets both predicted and contributed to the October 2014 U.S. Treasury Bond Flash Crash, and (b) mini-flash crashes are important phenomena with negative externalities that deserve much greater scholarly attention. PMID:29091931

  8. Controller evaluation of initial data link en route air traffic control services : mini study 3

    DOT National Transportation Integrated Search

    1991-06-01

    This report documents a Federal Aviation Administration controller evaluation of air traffic control (ATC) Data Link services planned for implementation in the en route ATC system. The main body of the report includes a detailed description of the ob...

  9. Dynamics differentiate between active and inactive inteins

    PubMed Central

    Cronin, Melissa; Coolbaugh, Michael J; Nellis, David; Zhu, Jianwei; Wood, David W.; Nussinov, Ruth; Ma, Buyong

    2014-01-01

    The balance between stability and dynamics for active enzymes can be somewhat quantified by studies of intein splicing and cleaving reactions. Inteins catalyze the ligation of flanking host exteins while excising themselves. The potential for applications led to engineering of a mini-intein splicing domain, where the homing endonuclease domain of the Mycobacterium tuberculosis RecA (Mtu recA) intein was removed. The remaining domains were linked by several short peptides, but splicing activity in all was substantially lower than the full-length intein. Native splicing activity was restored in some cases by a V67L mutation. Using computations and experiments, we examine the impact of this mutation on the stability and conformational dynamics of the mini-intein splicing domain. Molecular dynamics simulations were used to delineate the factors that determine the active state, including the V67L mini-intein mutant, and peptide linker. We found that (1) the V67L mutation lowers the global fluctuations in all modeled mini-inteins, stabilizing the mini-intein constructs; (2) the connecting linker length affects intein dynamics; and (3) the flexibilities of the linker and intein core are higher in the active structure. We have observed that the interaction of the linker region and a turn region around residues 35-41 provides the pathway for the allostery interaction. Our experiments reveal that intein catalysis is characterized by non-linear Arrhenius plot, confirming the significant contribution of protein conformational dynamics to intein function. We conclude that while the V67L mutation stabilizes the global structure, cooperative dynamics of all intein regions appear more important for intein function than high stability. Our studies suggest that effectively quenching the conformational dynamics of an intein through engineered allosteric interactions could deactivate intein splicing or cleaving. PMID:25087201

  10. Superscaling in electron-nucleus scattering and its link to CC and NC QE neutrino-nucleus scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbaro, M. B.; Amaro, J. E.; Caballero, J. A.

    2015-05-15

    The superscaling approach (SuSA) to neutrino-nucleus scattering, based on the assumed universality of the scaling function for electromagnetic and weak interactions, is reviewed. The predictions of the SuSA model for bot CC and NC differential and total cross sections are presented and compared with the MiniBooNE data. The role of scaling violations, in particular the contribution of meson exchange currents in the two-particle two-hole sector, is explored.

  11. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    PubMed

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  12. Support for designing waste sorting systems: A mini review.

    PubMed

    Rousta, Kamran; Ordoñez, Isabel; Bolton, Kim; Dahlén, Lisa

    2017-11-01

    This article presents a mini review of research aimed at understanding material recovery from municipal solid waste. It focuses on two areas, waste sorting behaviour and collection systems, so that research on the link between these areas could be identified and evaluated. The main results presented and the methods used in the articles are categorised and appraised. The mini review reveals that most of the work that offered design guidelines for waste management systems was based on optimising technical aspects only. In contrast, most of the work that focused on user involvement did not consider developing the technical aspects of the system, but was limited to studies of user behaviour. The only clear consensus among the articles that link user involvement with the technical system is that convenient waste collection infrastructure is crucial for supporting source separation. This mini review reveals that even though the connection between sorting behaviour and technical infrastructure has been explored and described in some articles, there is still a gap when using this knowledge to design waste sorting systems. Future research in this field would benefit from being multidisciplinary and from using complementary methods, so that holistic solutions for material recirculation can be identified. It would be beneficial to actively involve users when developing sorting infrastructures, to be sure to provide a waste management system that will be properly used by them.

  13. Mini-Rocket User Guide

    DTIC Science & Technology

    2007-08-01

    26 ISTC Simulation Comparisons ............................................................................... 29 STARS...Range Comparison Figure 8. ISTC Simulntioiz Comparisons 29 Mini-Rocket User Guide REAL-WORLD COMPARISON In particular, note the very high angle-of...not directly model the missile rigid body dynamics. The ISTC subsequently used Mini-Rocket as a driver to stimulate other models and as a risk

  14. 55 'Mini Sim' - innovative bite sized simulation teaching in a busy children's emergency department.

    PubMed

    Sunley, Rachel; Moloney, Karen; Parker, Jessica; Arrowsmith, Christopher; Brown, Kirsty; Wilson, Alex

    2017-12-01

    : Emergency Medicine requires a highly skilled workforce who are passionate about delivering excellent patient care. Shift patterns linked with the ever increasing numbers of patients who attend Emergency Departments puts strain on educating the workforce and fostering team togetherness.Our objective in devising and instigating the 'Mini Sim' programme was to embed regular in-situ simulation training to enhance the learning of all staff within our Emergency Department team, building a highly trained workforce to deliver excellent care within the remit of our busy department. The whole team is involved including junior nurses, senior nurses and all tiers of junior doctors including foundation, general practice and senior ED trainees (including Grid).'Mini Sim' takes place on a weekly basis, every Tuesday morning from 0930-1000. This timing is to ensure maximum participation from all staff. The setup is a fifteen minute simulation (one nurse, one junior doctor, one senior doctor) followed by fifteen minutes of debrief. The format includes an assessment of the participants confidence prior to 'Mini Sim' in the subject being practiced. This is rated on a numerical scale from 1 (being not confident at all) to 5 (being completely confident). The topics chosen are based on feedback from trainees and nurses on clinical skills they feel under confident in, (e.g., pelvic binder application, rapid sequence induction, sickle cell crisis), clinical incidents which have occurred around the Trust (e.g., seizures and access to benzodiazepines), National Patient Safety Alerts (e.g., phenytoin toxicity), protocols (e.g., abducted child, rapid tranquilisation for the acutely disturbed adolescent) , governance issues (e.g., blocked tracheostomy, resuscitation room rebuild) and competencies linked to RCEM objectives. The 'Mini Sim' then takes place in situ within the ED resus, ED main department or our short stay observation ward which is under the auspices of the Children's Emergency Department using real equipment and drugs. After the simulation a debrief is held and any additional teaching is carried out to embed learning. Each medical participant is then offered the opportunity to complete a work place based assessment on the 'Mini Sim' for their e-portfolio.emermed;34/12/A899-a/F1F1F1Figure 1Evaluation of impact of 'mini sim'The work flow of the department has been unaffected and we have received excellent written feedback from participants about the educational quality of the programme which has also shown improvements in staff confidence in dealing with a variety of emergency situations. We would suggest this model could be used in other departments for similar gain.emermed;34/12/A899-a/F2F2F2Figure 2. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Mini-Rocket User Guide

    DTIC Science & Technology

    2007-08-01

    26 8. ISTC Simulation Comparisons...Comparison c. Ground Range Comparison Figure 8. ISTC Simulation Comparisons Mini-Rocket User Guide REAL-WORLD COMPARISON 30 In particular, note...even though Mini-Rocket does not directly model the missile rigid body dynamics. The ISTC subsequently used Mini-Rocket as a driver to stimulate other

  16. Comparative analysis of numerical and experimental data of orthodontic mini-implants.

    PubMed

    Chatzigianni, Athina; Keilig, Ludger; Duschner, Heinz; Götz, Hermann; Eliades, Theodore; Bourauel, Christoph

    2011-10-01

    The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, 1.5 × 9 mm, and 2 × 7 mm). Mini-implants were inserted in two different ways, perpendicular to the bone surface or at 45 degrees to the direction of the applied load. Loading and boundary conditions in the FE models were adjusted to match the experimental situation, with the force applied on the neck of the mini-implants, along the mesio-distal direction up to a maximum of 0.5 N. Displacement and rotation of mini-implants after force application calculated by FEA were compared to previously recorded experimental deflections of the same mini-implants. Analysis of data with the Altman-Bland test and the Youden plot demonstrated good agreement between numerical and experimental findings (P = not significant) for the models selected. This study provides further evidence of the appropriateness of the FEA as an investigational tool in relevant research.

  17. Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study.

    PubMed

    Soğancı, Gökçe; Yazıcıoğlu, Hüseyin

    2016-01-01

    Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.

  18. Analytic and simulation studies on the use of torque-wheel actuators for the control of flexible robotic arms

    NASA Technical Reports Server (NTRS)

    Montgomery, Raymond C.; Ghosh, Dave; Kenny, Sean

    1991-01-01

    This paper presents results of analytic and simulation studies to determine the effectiveness of torque-wheel actuators in suppressing the vibrations of two-link telerobotic arms with attached payloads. The simulations use a planar generic model of a two-link arm with a torque wheel at the free end. Parameters of the arm model are selected to be representative of a large space-based robotic arm of the same class as the Space Shuttle Remote Manipulator, whereas parameters of the torque wheel are selected to be similar to those of the Mini-Mast facility at the Langley Research Center. Results show that this class of torque-wheel can produce an oscillation of 2.5 cm peak-to-peak in the end point of the arm and that the wheel produces significantly less overshoot when the arm is issued an abrupt stop command from the telerobotic input station.

  19. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    PubMed

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  20. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants.

    PubMed

    Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I

    2017-05-01

    The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.

  1. HARMONIZING HEALTH TECHNOLOGY ASSESSMENT PRACTICES IN UNIVERSITY HOSPITALS: TO WHAT EXTENT IS THE MINI-HTA MODEL SUITABLE IN THE FRENCH CONTEXT?

    PubMed

    Martelli, Nicolas; Devaux, Capucine; van den Brink, Hélène; Billaux, Mathilde; Pineau, Judith; Prognon, Patrice; Borget, Isabelle

    2017-01-01

    The number of new medical devices for individual use that are launched annually exceeds the assessment capacity of the French national health technology assessment (HTA) agency. This has resulted in hospitals, and particularly university hospitals (UHs), developing hospital-based HTA initiatives to support their decisions for purchasing innovative devices. However, the methodologies used in such hospitals have no common basis. The aim of this study was to assess a mini-HTA model as a potential solution to harmonize HTA methodology in French UHs. A systematic review was conducted on Medline, Embase, Health Technology Assessment database, and Google Scholar to identify published articles reporting the use of mini-HTA tools and decision support-like models. A survey was also carried out in eighteen French UHs to identify in-house decision support tools. Finally, topics evaluated in the Danish mini-HTA model and in French UHs were compared using Jaccard similarity coefficients. Our findings showed differences between topics evaluated in French UHs and those assessed in decision support models from the literature. Only five topics among the thirteen most evaluated in French UHs were similar to those assessed in the Danish mini-HTA model. The organizational and ethical/social impacts were rarely explored among the surveyed models used in French UHs when introducing new medical devices. Before its widespread and harmonized use in French UHs, the mini-HTA model would first require adaptations to the French context.

  2. Are Ducted Mini-Splits Worth It?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winkler, Jonathan M; Maguire, Jeffrey B; Metzger, Cheryn E.

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within themore » Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).« less

  3. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

    PubMed Central

    AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.

    2016-01-01

    SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force. PMID:28042449

  4. Orthodontic mechanics using mini-implant measured by FBG

    NASA Astrophysics Data System (ADS)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  5. A coherent free space optical link for long distance clock comparison, navigation, and communication: The Mini-Doll project

    NASA Astrophysics Data System (ADS)

    Djerroud, K.; Samain, E.; Clairon, A.; Acef, O.; Man, N.; Lemonde, P.; Wolf, P.

    2017-11-01

    We describe the realization of a 5 km free space coherent optical link through the turbulent atmosphere between a telescope and a ground target. We present the phase noise of the link, limited mainly by atmospheric turbulence and mechanical vibrations of the telescope and the target. We discuss the implications of our results for applications, with particular emphasis on optical Doppler ranging to satellites and long distance frequency transfer.

  6. In silico and in vitro methods to optimize the performance of experimental gastroretentive floating mini-tablets.

    PubMed

    Eberle, Veronika A; Häring, Armella; Schoelkopf, Joachim; Gane, Patrick A C; Huwyler, Jörg; Puchkov, Maxim

    2016-01-01

    Development of floating drug delivery systems (FDDS) is challenging. To facilitate this task, an evaluation method was proposed, which allows for a combined investigation of drug release and flotation. It was the aim of the study to use functionalized calcium carbonate (FCC)-based lipophilic mini-tablet formulations as a model system to design FDDS with a floating behavior characterized by no floating lag time, prolonged flotation and loss of floating capability after complete drug release. Release of the model drug caffeine from the mini-tablets was assessed in vitro by a custom-built stomach model. A cellular automata-based model was used to simulate tablet dissolution. Based on the in silico data, floating forces were calculated and analyzed as a function of caffeine release. Two floating behaviors were identified for mini-tablets: linear decrease of the floating force and maintaining of the floating capability until complete caffeine release. An optimal mini-tablet formulation with desired drug release time and floating behavior was developed and tested. A classification system for a range of varied floating behavior of FDDS was proposed. The FCC-based mini-tablets had an ideal floating behavior: duration of flotation is defined and floating capability decreases after completion of drug release.

  7. A three-dimensional finite element analysis for overdenture attachments supported by teeth and/or mini dental implants.

    PubMed

    Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang

    2012-12-01

    The aim of this study was to establish the optimum design and attachment combination to support an overdenture with minimal stress and flexing produced in the alveolar bone surrounding any natural teeth and/or mini dental implants. Twelve models were included in the study: the six main models (A, B, C, D, E, and F) were categorized according to the support designs of the overdenture prosthesis, and each model was further subdivided according to the attachment combinations into model 1: with Dalbo elliptic and/or O-ring attachments only and model 2: with flexible acrylic attachments. Vertical loads (35 N) and 17.5 N lateral loads under static conditions were applied to the models to simulate the occlusal forces following the concept of lingualized occlusion. All conditions were created using a finite element software program. Maximum von Mises stress at the level of the attachments and at the bone support foundation interfaces were compared in all 12 models. The flexing of the mandible and the attachments were also compared qualitatively. Stress on these models was analyzed after the given loading condition. The results showed that the model with three freestanding mini dental implants and flexible acrylic attachments showed the lowest von Mises stress and flexing, while the models with four freestanding mini dental implants and O-ring attachments showed the highest von Mises stress. Three freestanding mini dental implants with flexible acrylic attachment systems supporting an overdenture were better choices than four mini dental implants with O-ring attachment systems, which showed the maximum flexing and stress values in this qualitative comparison. © 2012 by the American College of Prosthodontists.

  8. Failure rates of mini-implants placed in the infrazygomatic region.

    PubMed

    Uribe, Flavio; Mehr, Rana; Mathur, Ajay; Janakiraman, Nandakumar; Allareddy, Veerasathpurush

    2015-01-01

    The purpose of this pilot study was to evaluate the failure rates of mini-implants placed in the infrazygomatic region and to evaluate factors that affect their stability. A retrospective cohort study of 30 consecutive patients (55 mini-implants) who had infrazygomatic mini-implants at a University Clinic were evaluated for failure rates. Patient, mini-implant, orthodontic, surgical, and mini-implant maintenance factors were evaluated by univariate logistic regression models for association to failure rates. A 21.8 % failure rate of mini-implants placed in the infazygomatic region was observed. None of the predictor variables were significantly associated with higher or lower odds for failed implants. Failure rates for infrazygomatic mini-implants were slightly higher than those reported in other maxilla-mandibular osseous locations. No predictor variables were found to be associated to the failure rates.

  9. Obesity induced during sexual maturation is linked to LDL-triacylglycerols in Yucatan miniature swine.

    PubMed

    Sébert, Sylvain P; Lecannu, Gérard; Sené, Sandrine; Hucteau, Séverine; Chetiveaux, Maud; Ouguerram, Khadija; Champ, Martine M-J

    2005-08-01

    The incidence of childhood obesity is rising dramatically throughout industrialised countries. To evaluate and study the impact of childhood obesity on lipoprotein metabolism, we developed a new animal model of premature obesity. Yucatan mini-pigs aged 4 months were studied over a 12-month period from childhood to adulthood. Animals were divided into two groups: the first group were overfed a Western misbalanced diet; the second group were normally fed a recommended human-type diet. Cholesterol and triacylglycerol concentrations in VLDL-, LDL- and HDL-lipoproteins were followed from baseline to adulthood by fast protein liquid chromatography. At 10 (the end of sexual maturation) and 16 months old (adulthood), liver, visceral and subcutaneous adipose tissues were sampled. Real-time RT-PCR was performed in order to compare apo AI, apo B, apo C-III, PPAR-alpha, insulin receptor and lipoprotein lipase gene expression between groups and ages. Differences between groups were observed only after sexual maturity. Adult overfed mini-pigs had a higher LDL-cholesterol:HDL-cholesterol ratio (P < 0.05; 0.55 (SE 0.06) for overfed v. 0.42 (SE 0.04) for normally fed pigs at the tenth month of the study). In both groups, VLDL-triacylglycerol decreased (P < 0.05). VLDL-triacylglycerol evolution in the overfed group was associated with an increase in LDL-triacylglycerol plasma concentrations (P < 0.05) after sexual maturation. LDL-triacylglycerol concentration in overfed mini-pigs went from an average of 0.28 mmol/l before sexual maturation to reach an average concentration of 0.56 mmol/l afterwards. This phenomenon has never been observed in similar studies when obesity is induced in adult mini-pigs and may represent a specific hallmark of an obesity induced during sexual maturity.

  10. Multi-Fidelity Simulation of a Turbofan Engine With Results Zoomed Into Mini-Maps for a Zero-D Cycle Simulation

    NASA Technical Reports Server (NTRS)

    Turner, Mark G.; Reed, John A.; Ryder, Robert; Veres, Joseph P.

    2004-01-01

    A Zero-D cycle simulation of the GE90-94B high bypass turbofan engine has been achieved utilizing mini-maps generated from a high-fidelity simulation. The simulation utilizes the Numerical Propulsion System Simulation (NPSS) thermodynamic cycle modeling system coupled to a high-fidelity full-engine model represented by a set of coupled 3D computational fluid dynamic (CFD) component models. Boundary conditions from the balanced, steady state cycle model are used to define component boundary conditions in the full-engine model. Operating characteristics of the 3D component models are integrated into the cycle model via partial performance maps generated from the CFD flow solutions using one-dimensional mean line turbomachinery programs. This paper highlights the generation of the high-pressure compressor, booster, and fan partial performance maps, as well as turbine maps for the high pressure and low pressure turbine. These are actually "mini-maps" in the sense that they are developed only for a narrow operating range of the component. Results are compared between actual cycle data at a take-off condition and the comparable condition utilizing these mini-maps. The mini-maps are also presented with comparison to actual component data where possible.

  11. Generative electronic background music system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazurowski, Lukasz

    In this short paper-extended abstract the new approach to generation of electronic background music has been presented. The Generative Electronic Background Music System (GEBMS) has been located between other related approaches within the musical algorithm positioning framework proposed by Woller et al. The music composition process is performed by a number of mini-models parameterized by further described properties. The mini-models generate fragments of musical patterns used in output composition. Musical pattern and output generation are controlled by container for the mini-models - a host-model. General mechanism has been presented including the example of the synthesized output compositions.

  12. Beyond standard model searches in the MiniBooNE experiment

    DOE PAGES

    Katori, Teppei; Conrad, Janet M.

    2014-08-05

    Tmore » he MiniBooNE experiment has contributed substantially to beyond standard model searches in the neutrino sector. he experiment was originally designed to test the Δ m 2 ~ 1 eV 2 region of the sterile neutrino hypothesis by observing ν e ( ν - e ) charged current quasielastic signals from a ν μ ( ν - μ ) beam. MiniBooNE observed excesses of ν e and ν - e candidate events in neutrino and antineutrino mode, respectively. o date, these excesses have not been explained within the neutrino standard model ( ν SM); the standard model extended for three massive neutrinos. Confirmation is required by future experiments such as MicroBooNE. MiniBooNE also provided an opportunity for precision studies of Lorentz violation. he results set strict limits for the first time on several parameters of the standard-model extension, the generic formalism for considering Lorentz violation. Most recently, an extension to MiniBooNE running, with a beam tuned in beam-dump mode, is being performed to search for dark sector particles. In addition, this review describes these studies, demonstrating that short baseline neutrino experiments are rich environments in new physics searches.« less

  13. Impact of a Ground Network of Miniaturized Laser Heterodyne Radiometers (mini-LHRs) on Global Carbon Flux Estimates

    NASA Astrophysics Data System (ADS)

    DiGregorio, A.; Wilson, E. L.; Palmer, P. I.; Mao, J.; Feng, L.

    2017-12-01

    We present the simulated impact of a small (50 instrument) ground network of NASA Goddard Space Flight Center's miniaturized laser heterodyne radiometer (mini-LHR), a small, low cost ( 50k), portable, and high precision CH4 and CO2 measuring instrument. Partnered with AERONET as a non-intrusive accessory, the mini-LHR is able to leverage the 500+ instrument AERONET network for rapid network deployment and testing, and simultaneously retrieve co-located aerosol data, an important input for sattelite measurements. This observing systems simulation experiment (OSSE) uses the 3-D GEOS-Chem chemistry transport model and 50 strategically selected sites to model flux estimate uncertainty reduction of both TCCON and mini-LHR instruments. We found that 50 mini-LHR sites are capable of improving global uncertainty by up to 70%, with local improvements in the Southern Hemisphere reaching to 90%. Our studies show that addition of the mini-LHR to current ground networks will play a major role in reduction of global carbon flux uncertainty.

  14. Computing, Environment and Life Sciences | Argonne National Laboratory

    Science.gov Websites

    engineer receives prestigious medal August 18, 2016 Software optimized on Mira advances design of mini » Back to top Twitter Flickr Facebook Linked In YouTube Pinterest Google Plus Computing, Environment and

  15. Performance analysis of mini-propellers based on FlightGear

    NASA Astrophysics Data System (ADS)

    Vogeltanz, Tomáš

    2016-06-01

    This paper presents a performance analysis of three mini-propellers based on the FlightGear flight simulator. Although a basic propeller analysis has to be performed before the use of FlightGear, for a complex and more practical performance analysis, it is advantageous to use a propeller model in cooperation with a particular aircraft model. This approach may determine whether the propeller has sufficient quality in respect of aircraft requirements. In the first section, the software used for the analysis is illustrated. Then, the parameters of the analyzed mini-propellers and the tested UAV are described. Finally, the main section shows and discusses the results of the performance analysis of the mini-propellers.

  16. Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study.

    PubMed

    Hedayati, Zohreh; Shomali, Mehrdad

    2016-12-01

    Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.

  17. Microwave Scanning System Correlations

    DTIC Science & Technology

    2010-08-11

    The follow equipment is needed for each of the individual scanning systems: Handheld Scanner Equipment list 1. Dell Netbook (with the...proper software installed by Evisive) 2. Bluetooth USB port transmitter 3. Handheld Probe 4. USB to mini-USB Converter (links camera to netbook

  18. How lay people respond to messages about genetics, health, and race.

    PubMed

    Condit, C; Bates, B

    2005-08-01

    There is a growing movement in medical genetics to develop, implement, and promote a model of race-based medicine. Although race-based medicine may become a widely disseminated standard of care, messages that advocate race-based selection for diagnosing, screening and prescribing drugs may exacerbate health disparities. These messages are present in clinical genetic counseling sessions, mass media, and everyday talk. Messages promoting linkages among genes, race, and health and messages emphasizing genetic causation may promote both general racism and genetically based racism. This mini-review examines research in three areas: studies that address the effects of these messages about genetics on levels of genetic determinism and genetic discrimination; studies that address the effects of these messages on attitudes about race; and, studies of the impacts of race-specific genetic messages on recipients. Following an integration of this research, this mini-review suggests that the current literature appears fragmented because of methodological and measurement issues and offers strategies for future research. Finally, the authors offer a path model to help organize future research examining the effects of messages about genetics on socioculturally based racism, genetically based racism, and unaccounted for racism. Research in this area is needed to understand and mitigate the negative attitudinal effects of messages that link genes, race, and health and/or emphasize genetic causation.

  19. Design and Performance Evaluation of a UWB Communication and Tracking System for Mini-AERCam

    NASA Technical Reports Server (NTRS)

    Barton, Richard J.

    2005-01-01

    NASA Johnson Space Center (JSC) is developing a low-volume, low-mass, robotic free-flying camera known as Mini-AERCam (Autonomous Extra-vehicular Robotic Camera) to assist the International Space Station (ISS) operations. Mini-AERCam is designed to provide astronauts and ground control real-time video for camera views of ISS. The system will assist ISS crewmembers and ground personnel to monitor ongoing operations and perform visual inspections of exterior ISS components without requiring extravehicular activity (EAV). Mini-AERCam consists of a great number of subsystems. Many institutions and companies have been involved in the R&D for this project. A Mini-AERCam ground control system has been studied at Texas A&M University [3]. The path planning and control algorithms that direct the motions of Mini-AERCam have been developed through the joint effort of Carnegie Mellon University and the Texas Robotics and Automation Center [5]. NASA JSC has designed a layered control architecture that integrates all functions of Mini-AERCam [8]. The research described in this report is part of a larger effort focused on the communication and tracking subsystem that is designed to perform three major tasks: 1. To transmit commands from ISS to Mini-AERCam for control of robotic camera motions (downlink); 2. To transmit real-time video from Mini-AERCam to ISS for inspections (uplink); 3. To track the position of Mini-AERCam for precise motion control. The ISS propagation environment is unique due to the nature of the ISS structure and multiple RF interference sources [9]. The ISS is composed of various truss segments, solar panels, thermal radiator panels, and modules for laboratories and crew accommodations. A tracking system supplemental to GPS is desirable both to improve accuracy and to eliminate the structural blockage due to the close proximity of the ISS which could at times limit the number of GPS satellites accessible to the Mini-AERCam. Ideally, the tracking system will be a passive component of the communication system which will need to operate in a time-varying multipath environment created as the robot camera moves over the ISS structure. In addition, due to many interference sources located on the ISS, SSO, LEO satellites and ground-based transmitters, selecting a frequency for the ISS and Mini-AERCam link which will coexist with all interferers poses a major design challenge. To meet all of these challenges, ultrawideband (UWB) radio technology is being studied for use in the Mini-AERCam communication and tracking subsystem. The research described in this report is focused on design and evaluation of passive tracking system algorithms based on UWB radio transmissions from mini-AERCam.

  20. Generation of sequence signatures from DNA amplification fingerprints with mini-hairpin and microsatellite primers.

    PubMed

    Caetano-Anollés, G; Gresshoff, P M

    1996-06-01

    DNA amplification fingerprinting (DAF) with mini-hairpins harboring arbitrary "core" sequences at their 3' termini were used to fingerprint a variety of templates, including PCR products and whole genomes, to establish genetic relationships between plant tax at the interspecific and intraspecific level, and to identify closely related fungal isolates and plant accessions. No correlation was observed between the sequence of the arbitrary core, the stability of the mini-hairpin structure and DAF efficiency. Mini-hairpin primers with short arbitrary cores and primers complementary to simple sequence repeats present in microsatellites were also used to generate arbitrary signatures from amplification profiles (ASAP). The ASAP strategy is a dual-step amplification procedure that uses at least one primer in each fingerprinting stage. ASAP was able to reproducibly amplify DAF products (representing about 10-15 kb of sequence) following careful optimization of amplification parameters such as primer and template concentration. Avoidance of primer sequences partially complementary to DAF product termini was necessary in order to produce distinct fingerprints. This allowed the combinatorial use of oligomers in nucleic acid screening, with numerous ASAP fingerprinting reactions based on a limited number of primer sequences. Mini-hairpin primers and ASAP analysis significantly increased detection of polymorphic DNA, separating closely related bermudagrass (Cynodon) cultivars and detecting putatively linked markers in bulked segregant analysis of the soybean (Glycine max) supernodulation (nitrate-tolerant symbiosis) locus.

  1. Lateral forces exerted through ball or bar attachments in relation to the inclination of mini-implant underneath overdentures: in vitro study.

    PubMed

    Takagaki, Kyozo; Gonda, Tomoya; Maeda, Yoshinobu

    2015-09-01

    Lateral force to mini-implants should be avoided because mini-implants are weak mechanically because of its small diameter. Overdentures retained by mini-implants are usually formed using ball attachments. However, bar attachments can offer the advantage of splinting the mini-implants. This study examined the effect of attachments in withstanding these lateral forces in tilted mini-implants of overdentures. Strain gauges were attached to the mini-implants (2.5 × 18 mm) embedded in an acrylic resin block. Two mini-implants were inserted vertically (Control) or with one mini-implant inclined at 10° or 20° (10-inclined and 20-inclined, respectively). The female portions of the attachments were secured to the denture base. A prefabricated ball attachment and CAD/CAM-fabricated bar attachment were compared. A vertical load of 49 N was applied to the occlusal surface at a distance 10 mm away from the center of two mini-implants. The lateral force borne by the mini-implants was measured via the attached strain gauge. Mann-Whitney U-test and an analysis of Bonferroni correction were used to compare differences between the two attachments and among the three models (P < 0.05). The lateral force exerted to the inclined mini-implant was significantly greater than that borne by a vertical mini-implant for both attachment types. The lateral force on the 20° inclined mini-implants with bar attachments was smaller than that on mini-implants with ball attachments. Inclined mini-implants are subjected to greater stresses than vertical ones, and a bar attachment can reduce the lateral forces borne by the mini-implant when one mini-implant inclined at 20°. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Fully customized placement of orthodontic miniplates: a novel clinical technique

    PubMed Central

    2014-01-01

    Introduction The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. Methods In order to apply this new technique, a cone-beam image of the insertion area is required. A software (Galaxy Sirona, Bensheim, Germany) is used to construct a three-dimensional image of the scanned area and to virtually determine the exact location of the mini-plate as well as the position of the fixation screws. A stereolithographic model (STL) is then created by means of a three-dimensional scanner. Prior to its surgical insertion, the bone plate is adapted to the stereo-lithographic model. Finally, a custom transfer jig is fabricated in order to assist with accurate placement of the mini-plate intra-operatively. Results The presented technique minimizes intra-operative decision making, because the final position of the bone plate is determined pre-surgically. This significantly reduces the duration of the surgical procedure and improves its outcome. Conclusions A novel method for surgical placement of orthodontic mini-plates is presented. The technique facilitates accurate adaptation of mini-plates and insertion of retaining surgical screws; thereby enabling clinicians to more confidently increase the use of bone plates, especially in anatomical areas where the success of non-osseointegrated mini-screws is less favorable. PMID:24886597

  3. Microbiology and potential applications of aerobic methane oxidation coupled to denitrification (AME-D) process: A review.

    PubMed

    Zhu, Jing; Wang, Qian; Yuan, Mengdong; Tan, Giin-Yu Amy; Sun, Faqian; Wang, Cheng; Wu, Weixiang; Lee, Po-Heng

    2016-03-01

    Aerobic methane oxidation coupled to denitrification (AME-D) is an important link between the global methane and nitrogen cycles. This mini-review updates discoveries regarding aerobic methanotrophs and denitrifiers, as a prelude to spotlight the microbial mechanism and the potential applications of AME-D. Until recently, AME-D was thought to be accomplished by a microbial consortium where denitrifying bacteria utilize carbon intermediates, which are excreted by aerobic methanotrophs, as energy and carbon sources. Potential carbon intermediates include methanol, citrate and acetate. This mini-review presents microbial thermodynamic estimations and postulates that methanol is the ideal electron donor for denitrification, and may serve as a trophic link between methanotrophic bacteria and denitrifiers. More excitingly, new discoveries have revealed that AME-D is not only confined to the conventional synergism between methanotrophic bacteria and denitrifiers. Specifically, an obligate aerobic methanotrophic bacterium, Methylomonas denitrificans FJG1, has been demonstrated to couple partial denitrification with methane oxidation, under hypoxia conditions, releasing nitrous oxide as a terminal product. This finding not only substantially advances the understanding of AME-D mechanism, but also implies an important but unknown role of aerobic methanotrophs in global climate change through their influence on both the methane and nitrogen cycles in ecosystems. Hence, further investigation on AME-D microbiology and mechanism is essential to better understand global climate issues and to develop niche biotechnological solutions. This mini-review also presents traditional microbial techniques, such as pure cultivation and stable isotope probing, and powerful microbial techniques, such as (meta-) genomics and (meta-) transcriptomics, for deciphering linked methane oxidation and denitrification. Although AME-D has immense potential for nitrogen removal from wastewater, drinking water and groundwater, bottlenecks and potential issues are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evaluation of disintegrants functionality for orodispersible mini tablets.

    PubMed

    Soulairol, Ian; Chaheen, Mohammad; Tarlier, Nicolas; Aubert, Adrien; Bataille, Bernard; Sharkawi, Tahmer

    2017-11-01

    This work evaluates the functionalities of different superdisintegrants (SD) for manufacturing orodispersible mini tablets (ODMT) by direct compression. Twenty-three formulations varying in SD type, concentration, and lubricant were used to manufacture ODMT. The ODMT were then characterized for the following properties: friability, porosity, tensile strength, in vivo and in vitro disintegration time (DT). The results show that the presence, type, and concentration of SD did not influence friability, porosity, or tablet tensile strength. With regards to in vivo DT, only cross-linked poly (vinyl pyrrolidone) improved DT in all the tested formulations. Results also showed that when using microcrystalline cellulose (MCC) above 20% in the formulation, DT is longer. Cross-linked carboxymethyl cellulose accelerates DT when the MCC content is less than 20%. As for cross-linked carboxymethyl starch and calcium alginate showed no improvement on DT. Results for in vitro DT were all shorter than in vivo results and there was no correlation with the in vivo evaluation. This study shows that there is a need to develop better in vitro testing that precisely simulates in vivo conditions and that are adapted to ODMT. This standardization of the test methods for ODMTs must be accompanied by an improvement in the comprehension of SD mechanisms.

  5. Transverse enhancement model and MiniBooNE charge current quasi-elastic neutrino scattering data

    NASA Astrophysics Data System (ADS)

    Sobczyk, Jan T.

    2012-01-01

    Recently proposed Transverse Enhancement Model of nuclear effects in Charge Current Quasi-Elastic neutrino scattering (A. Bodek, H.S. Budd, M.E. Christy, Eur. Phys. J. C 71:1726, 2011) is confronted with the MiniBooNE high statistics experimental data.

  6. Spectral Resolution-linked Bias in Transit Spectroscopy of Extrasolar Planets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deming, Drake; Sheppard, Kyle

    We re-visit the principles of transmission spectroscopy for transiting extrasolar planets, focusing on the overlap between the planetary spectrum and the illuminating stellar spectrum. Virtually all current models of exoplanetary transmission spectra utilize an approximation that is inaccurate when the spectrum of the illuminating star has a complex line structure, such as molecular bands in M-dwarf spectra. In those cases, it is desirable to model the observations using a coupled stellar–planetary radiative transfer model calculated at high spectral resolving power, followed by convolution to the observed resolution. Not consistently accounting for overlap of stellar M-dwarf and planetary lines at highmore » spectral resolution can bias the modeled amplitude of the exoplanetary transmission spectrum, producing modeled absorption that is too strong. We illustrate this bias using the exoplanet TRAPPIST-1b, as observed using Hubble Space Telescope /WFC3. The bias in this case is about 250 ppm, 12% of the modeled transit absorption. Transit spectroscopy using JWST will have access to longer wavelengths where the water bands are intrinsically stronger, and the observed signal-to-noise ratios will be higher than currently possible. We therefore expect that this resolution-linked bias will be especially important for future JWST observations of TESS-discovered super-Earths and mini-Neptunes transiting M-dwarfs.« less

  7. Spectral Resolution-linked Bias in Transit Spectroscopy of Extrasolar Planets

    NASA Astrophysics Data System (ADS)

    Deming, Drake; Sheppard, Kyle

    2017-05-01

    We re-visit the principles of transmission spectroscopy for transiting extrasolar planets, focusing on the overlap between the planetary spectrum and the illuminating stellar spectrum. Virtually all current models of exoplanetary transmission spectra utilize an approximation that is inaccurate when the spectrum of the illuminating star has a complex line structure, such as molecular bands in M-dwarf spectra. In those cases, it is desirable to model the observations using a coupled stellar-planetary radiative transfer model calculated at high spectral resolving power, followed by convolution to the observed resolution. Not consistently accounting for overlap of stellar M-dwarf and planetary lines at high spectral resolution can bias the modeled amplitude of the exoplanetary transmission spectrum, producing modeled absorption that is too strong. We illustrate this bias using the exoplanet TRAPPIST-1b, as observed using Hubble Space Telescope/WFC3. The bias in this case is about 250 ppm, 12% of the modeled transit absorption. Transit spectroscopy using JWST will have access to longer wavelengths where the water bands are intrinsically stronger, and the observed signal-to-noise ratios will be higher than currently possible. We therefore expect that this resolution-linked bias will be especially important for future JWST observations of TESS-discovered super-Earths and mini-Neptunes transiting M-dwarfs.

  8. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Podorson, David; Varshney, Kapil

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programsmore » are discussed in detail.« less

  9. Replacing Resistance Heating with Mini-Split Heat Pumps, Sharon, Connecticut (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programsmore » are discussed in detail.« less

  10. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Podorson, D.; Varshney, K.

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programsmore » are discussed in detail.« less

  11. Identification of genetic markers linked to anthracnose resistance in sorghum using association analysis.

    PubMed

    Upadhyaya, Hari D; Wang, Yi-Hong; Sharma, Rajan; Sharma, Shivali

    2013-06-01

    Anthracnose in sorghum caused by Colletotrichum sublineolum is one of the most destructive diseases affecting sorghum production under warm and humid conditions. Markers and genes linked to resistance to the disease are important for plant breeding. Using 14,739 SNP markers, we have mapped eight loci linked to resistance in sorghum through association analysis of a sorghum mini-core collection consisting of 242 diverse accessions evaluated for anthracnose resistance for 2 years in the field. The mini-core was representative of the International Crops Research Institute for the Semi-Arid Tropics' world-wide sorghum landrace collection. Eight marker loci were associated with anthracnose resistance in both years. Except locus 8, disease resistance-related genes were found in all loci based on their physical distance from linked SNP markers. These include two NB-ARC class of R genes on chromosome 10 that were partially homologous to the rice blast resistance gene Pib, two hypersensitive response-related genes: autophagy-related protein 3 on chromosome 1 and 4 harpin-induced 1 (Hin1) homologs on chromosome 8, a RAV transcription factor that is also part of R gene pathway, an oxysterol-binding protein that functions in the non-specific host resistance, and homologs of menthone:neomenthol reductase (MNR) that catalyzes a menthone reduction to produce the antimicrobial neomenthol. These genes and markers may be developed into molecular tools for genetic improvement of anthracnose resistance in sorghum.

  12. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC) among a heterogeneous sample of long-term cancer survivors: A cross-sectional study

    PubMed Central

    2012-01-01

    Background The mini-Mental Adjustment to Cancer Scale (mini-MAC) is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. Methods RUMM 2030 was used to analyse the mini-MAC data (n=851). Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI), response format, local dependency, targeting, item bias (or differential item functioning -DIF), and dimensionality. Results For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales – Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. Conclusions The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of adaptive and maladaptive coping, extensive modifications were necessary to achieve this result. Further exploration and validation of over-arching subscales assessing adaptive and maladaptive coping is necessary with cancer survivors. PMID:22607052

  13. Long-term changes in ozone mini-hole event frequency over the Northern Hemisphere derived from ground-based measurements

    NASA Astrophysics Data System (ADS)

    Krzycin, Janusz W.

    2002-10-01

    Decadal changes of ozone mini-hole event appearance over the Northern Hemisphere midlatitudes are examined based on daily total ozone data from seven stations having long records (four decades or more) of ozone observations. The various threshold methods for accepting and rejecting the ozone minima as mini-holes are examined. Mini-hole event activity is seen to be rather stable when averaged over a decadal time scale if the mini-holes are selected as large negative departures (exceeding 20%) relative to the moving long-term total ozone reference. The results are compared with a previous ozone mini-hole climatology derived from satellite data (TOMS measurements on board the Nimbus-7 satellite for the period 1978-93). A nonlinear statistical model (MARS), which takes into account various total ozone dynamical proxies (from NCEP-NCAR reanalysis), is used to study dynamical factors responsible for the ozone extremes over Arosa in the period 1950-99. The model explains as much as 95% of the total variance of the ozone extremes. The model-observation differences averaged over the decadal intervals are rather smooth throughout the whole period analysed. It is suggested that the short-term dynamical processes controlling the appearance of ozone extremes influenced the ozone field in a similar way before and after the onset of abrupt ozone depletion in the early 1980s. The analysis of the ozone profile and the tropopause pressure (from the ozonesondings over Hohenpeissenberg, 1966-99) during mini-hole events shows 60% ozone reduction in the lower stratosphere and an approximately 50 hPa upward shift of the thermal tropopause there.

  14. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    PubMed

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Reviews Equipment: Data logger Book: Imagined Worlds Equipment: Mini data loggers Equipment: PICAXE-18M2 data logger Books: Engineering: A Very Short Introduction and To Engineer Is Human Book: Soap, Science, & Flat-Screen TVs Equipment: uLog and SensorLab Web Watch

    NASA Astrophysics Data System (ADS)

    2012-07-01

    WE RECOMMEND Data logger Fourier NOVA LINK: data logging and analysis To Engineer is Human Engineering: essays and insights Soap, Science, & Flat-Screen TVs People, politics, business and science overlap uLog sensors and sensor adapter A new addition to the LogIT range offers simplicity and ease of use WORTH A LOOK Imagined Worlds Socio-scientific predictions for the future Mini light data logger and mini temperature data logger Small-scale equipment for schools SensorLab Plus LogIT's supporting software, with extra features HANDLE WITH CARE CAXE110P PICAXE-18M2 data logger Data logger 'on view' but disappoints Engineering: A Very Short Introduction A broad-brush treatment fails to satisfy WEB WATCH Two very different websites for students: advanced physics questions answered and a more general BBC science resource

  16. Production of extended release mini-tablets using directly compressible grades of HPMC.

    PubMed

    Mohamed, Faiezah A A; Roberts, Matthew; Seton, Linda; Ford, James L; Levina, Marina; Rajabi-Siahboomi, Ali R

    2013-11-01

    Hypromellose (HPMC) has been previously used to control drug release from mini-tablets. However, owing to poor flow, production of mini-tablets containing high HPMC levels is challenging. Directly compressible (DC) HPMC grades have been developed by Dow Chemical Company. To compare the properties of HPMC DC (METHOCEL™ K4M and K100M) with regular (REG) HPMC grades. Particle size distribution and flowability of HPMC REG and DC were evaluated. 3 mm mini-tablets, containing hydrocortisone or theophylline as model drugs and 40% w/w HPMC DC or REG were produced. Mini-tablets containing HPMC DC grades were manufactured using a rotary press simulator at forces between 2-4 kN and speeds of 5, 10, 15 or 20 rpm. Mini-tablets containing HPMC REG were produced manually. The improved flowability of HPMC DC grades, which have a narrower particle size distribution and larger particle sizes, meant that simulated large scale production of mini-tablets with good weight uniformity (CV 1.79-4.65%) was feasible. It was not possible to automatically manufacture mini-tablets containing HPMC REG due to the poor flowability of the formulations. Drug release from mini-tablets comprising HPMC DC and REG were comparable. Mini-tablets containing HPMC DC illustrated a higher tensile strength compared to mini-tablets made with HPMC REG. Mini-tablets produced with HPMC DC at different compression speeds had similar drug release profiles. Production of extended release mini-tablets was successfully achieved when HPMC DC was used. Drug release rate was not influenced by the different HPMC DC grades (K4M or K100M) or production speed.

  17. A feasibility study of the Mini-AFTER telephone intervention for the management of fear of recurrence in breast cancer survivors: a mixed-methods study protocol.

    PubMed

    Cruickshank, Susanne; Steel, Emma; Fenlon, Deborah; Armes, Jo; Scanlon, Karen; Banks, Elspeth; Humphris, Gerald

    2018-01-01

    Fear of recurrence (FoR) is a major concern for patients following treatment for primary breast cancer, affecting 60-99% of breast cancer survivors. Mini-AFTER is a brief intervention developed to address this fear, that breast care nurses are ideally placed to deliver. However, their interest in delivering such an intervention is unknown and crucial to its introduction. This study aims to assess the perceived feasibility of the Mini-AFTER telephone intervention for implementation by breast care nurses to manage moderate levels of fear of recurrence among breast cancer survivors. A sequential explanatory mixed-methods design will be used, informed by normalisation process theory (NPT). The design will be guided by the stages of NPT. Specifically, understanding and evaluating the process (implementation) that would enable an intervention, such as the Mini-AFTER, not only to be operationalised and normalised into everyday work (embedded) but also sustained in practice (integration). Phase 1: all members on the UK Breast Cancer Care Nursing Network database ( n  = 905) will be emailed a link to a web-based survey, designed to investigate how breast cancer survivors' FoR is identified and managed within current services and their willingness to deliver the Mini-AFTER. Phase 2: a purposive sample of respondents ( n  = 20) will be interviewed to build upon the responses in phase 1 and explore breast care nurses' individual views on the importance of addressing fear of recurrence in their clinical consultations, interest in the Mini-AFTER intervention, the content, skills required and challenges to deliver the intervention. This study will provide information about the willingness of breast care nurses (BCNs) to provide a structured intervention to manage fear of recurrence. It will identify barriers and facilitators for effective delivery and inform the future design of a larger trial of the Mini-AFTER intervention.

  18. Late-stage development of the Bryant Canyon turbidite pathway on the Louisiana continental slope

    USGS Publications Warehouse

    Twichell, David C.; Nelson, Hans; Damuth, John E.

    2000-01-01

    GLORIA sidescan imagery, multibeam bathymetry, seismic profiles, and piston cores (3–5 m penetration) reveal the near-surface geology of the Bryant Canyon turbidite pathway on the continental margin of Louisiana. This pathway extends from the continental shelf edge, across the continental slope, to a deep-sea fan on the continental rise. The pathway is narrow (<2 km) where it crosses shallow salt deposits. Turbidites have been sampled from these narrow segments, and radiocarbon dates indicate that some of them accumulated as recently as 10,150 yr B.P. The pathway broadens however, where it crosses mini-basins whose floors are covered largely by muddy mass-transport deposits and coarse silt turbidites. Mass-transport deposits in the upper 4.7 m of cores from the floors of mini-basins accumulated 18,140-3,400 yr. BP. Seismic profiles show that the mass-transport deposits in some of the mini-basins are as much as 225 milliseconds thick and that turbidites in the basin floor are buried by these deposits. Salt movement has had a major impact on this pathway, and its thalweg no longer has a continuous down-slope gradient. Some mini-basin floors along the pathway are now more than 500 m deeper than their basin’s spill point. We propose a 6-stage conceptual model to explain our observations for the evolution of a mini-basin along this turbidite pathway. In this model, an active channel feeds sand to a mini-basin (Stabe B). Once the mini-basin is filled, the sand deposit is entrenched by a bypass channel (Stage C). When the turbidite system shuts off, salt migration oversteepens the mini-basin walls (Stage D) which collapse and create a layer of mass-transport deposits on the mini-basin floor (Stage E). The depositional succession is capped by a layer of highstand hemipelagic drape (Stage F). The Bryant Canyon turbidite pathway provides a recent example of a large turbidite pathway in the Gulf of Mexico that crosses an area of active salt tectonics thus providing a conceptual model for older systems in similar settings. In Bryant Canyon, thick turbidite sands presumably are found in mini-basins however, they are sealed by thick, fine-grained, mass-transport deposits which terminate mini-basin turbidite deposition cycles. The importance of mass-transport deposits in basins along this turbidite pathway is in startling contrast to the Trinity-Brazos pathway whose shallow subsurface expression is virtually free of mass-transport deposits and has undergone minimal deformation by salt movement.

  19. Aspects of alcohol use disorder affecting social cognition as assessed using the Mini Social and Emotional Assessment (mini-SEA).

    PubMed

    Cox, Sharon; Bertoux, Maxime; Turner, John J D; Moss, Antony; Locker, Kirsty; Riggs, Kevin

    2018-06-01

    Alcohol Use Disorder (AUD) is associated with problems with processing complex social scenarios. Little is known about the relationship between distinct AUD-related factors (e.g., years of problematic drinking), aspects of cognitive function and dysfunction in individuals diagnosed with AUD, and the relative impact these may have on social cognition. To explore differences in social cognition between a group of participants diagnosed with AUD and controls, using a clinical measure, the Mini Social and Emotional Assessment (mini-SEA). The mini-SEA was used to evaluate social and emotional understanding through a facial emotional recognition task and by utilising a series of social scenes some of which contain a faux pas (social error). Eighty-five participants (individuals with AUD and controls) completed demographic questions and a general cognitive and social cognitive test battery over three consecutive days. Between group analyses revealed that the participants with AUD performed less well on the faux pas test, and differences were also revealed in the emotional facial recognition task. Years of problematic alcohol consumption was the strongest predictor of poor ToM reasoning. These results suggest a strong link between AUD chronicity and social cognition, though the direction of this relationship needs further elucidation. This may be of clinical relevance to abstinence and relapse management, as basic social cognition skills and ability to maintain interpersonal relationships are likely to be crucial to recovery. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A Miniature Swine Model for Stem Cell-Based De Novo Regeneration of Dental Pulp and Dentin-Like Tissue.

    PubMed

    Zhu, Xiaofei; Liu, Jie; Yu, Zongdong; Chen, Chao-An; Aksel, Hacer; Azim, Adham A; Huang, George T-J

    2018-02-01

    The goal of this study was to establish mini-swine as a large animal model for stem cell-based pulp regeneration studies. Swine dental pulp stem cells (sDPSCs) were isolated from mini-swine and characterized in vitro. For in vivo studies, we first employed both ectopic and semi-orthotopic study models using severe combined immunodeficiency mice. One is hydroxyapatite-tricalcium phosphate (HA/TCP) model for pulp-dentin complex formation, and the other is tooth fragment model for complete pulp regeneration with new dentin depositing along the canal walls. We found that sDPSCs are similar to their human counterparts exhibiting mesenchymal stem cell characteristics with ability to form colony forming unit-fibroblastic and odontogenic differentiation potential. sDPSCs formed pulp-dentin complex in the HA/TCP model and showed pulp regeneration capacity in the tooth fragment model. We then tested orthotopic pulp regeneration on mini-swine including the use of multi-rooted teeth. Using autologous sDPSCs carried by hydrogel and transplanted into the mini-swine root canal space, we observed regeneration of vascularized pulp-like tissue with a layer of newly deposited dentin-like (rD) tissue or osteodentin along the canal walls. In some cases, dentin bridge-like structure was observed. Immunohistochemical analysis detected the expression of nestin, dentin sialophosphoprotein, dentin matrix protein 1, and bone sialoprotein in odontoblast-like cells lining against the produced rD. We also tested the use of allogeneic sDPSCs for the same procedures. Similar findings were observed in allogeneic transplantation. This study is the first to show an establishment of mini-swine as a suitable large animal model utilizing multi-rooted teeth for further cell-based pulp regeneration studies.

  1. Improving Preservice Elementary Teachers' Writing in a Science Context

    ERIC Educational Resources Information Center

    Everett, Susan; Luera, Gail; Otto, Charlotte

    2008-01-01

    The authors investigated whether a series of mini prewriting assignments linked to a formal paper describing an original research project would improve preservice elementary teachers' writing abilities in a science context. They compared 38 final reports from students who completed the prewriting assignments with 38 reports randomly selected from…

  2. Novel miniature mobile cardiac catheterization laboratory for critical cardiovascular disease following natural disasters: a feasibility study.

    PubMed

    Han, Ya-ling; Liang, Zhuo; Yao, Tian-ming; Sun, Jing-yang; Liang, Ming; Huo, Yu; Wang, Geng; Wang, Xiao-zeng; Liang, Yan-chun; Meng, Wei-hong

    2012-03-01

    Natural disasters have been frequent in recent years. Effective treatment of patients with cardiovascular disease following natural disasters is an unsolved problem. We aimed to develop a novel miniature mobile cardiac catheterization laboratory (Mini Mobile Cath Lab) to provide emergency interventional services for patients with critical cardiovascular disease following natural disasters. A feasibility study was performed by testing the Mini Mobile Cath Lab on dogs with ST-elevation myocardial infarction (STEMI) model in a hypothetical natural-disaster-stricken area. The Mini Mobile Cath Lab was transported to the hypothetical natural-disaster-stricken area by truck. Coronary angiography and primary percutaneous coronary intervention (PCI) were performed on six dogs with STEMI model. The transportation and transformation of the Mini Mobile Cath Lab were monitored and its functioning was evaluated through the results of animal experiments. The Mini Mobile Cath Lab could be transported by truck at an average speed of 80 km/h on mountain roads during daytime in the winter, under conditions of light snow (-15°C to -20°C/-68°F to -59°F). The average time required to prepare the Mini Mobile Cath Lab after transportation, in a wetland area, was 30 minutes. Coronary angiography, and primary PCI were performed successfully. This preliminary feasibility study of the use of the Mini Mobile Cath Lab for emergency interventional treatment of dogs with STEMI indicated that it may perform well in the rescue of critical cardiovascular disease following natural disasters.

  3. Revisiting the stability of mini-implants used for orthodontic anchorage.

    PubMed

    Yao, Chung-Chen Jane; Chang, Hao-Hueng; Chang, Jenny Zwei-Chieng; Lai, Hsiang-Hua; Lu, Shao-Chun; Chen, Yi-Jane

    2015-11-01

    The aim of this study is to comprehensively analyze the potential factors affecting the failure rates of three types of mini-implants used for orthodontic anchorage. Data were collected on 727 mini-implants (miniplates, predrilled titanium miniscrews, and self-drilling stainless steel miniscrews) in 220 patients. The factors related to mini-implant failure were investigated using a Chi-square test for univariate analysis and a generalized estimating equation model for multivariate analysis. The failure rate for miniplates was significantly lower than for miniscrews. All types of mini-implants, especially the self-drilling stainless steel miniscrews, showed decreased stability if the previous implantation had failed. The stability of predrilled titanium miniscrews and self-drilling stainless steel miniscrews were comparable at the first implantation. However, the failure rate of stainless steel miniscrews increased at the second implantation. The univariate analysis showed that the following variables had a significant influence on the failure rates of mini-implants: age of patient, type of mini-implant, site of implantation, and characteristics of the soft tissue around the mini-implants. The generalized estimating equation analysis revealed that mini-implants with miniscrews used in patients younger than 35 years, subjected to orthodontic loading after 30 days and implanted on the alveolar bone ridge, have a significantly higher risk of failure. This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly. Copyright © 2014. Published by Elsevier B.V.

  4. [Social phobia in anorexia nervosa: evolution during the care].

    PubMed

    Coulon, N; Jeammet, P; Godart, N

    2009-12-01

    The links between anorexia nervosa (AN) and anxiety disorders, and particularly social phobia, are little known. However, social phobia occurs frequently in AN. Some studies have shown reduction in anxious and depressive symptomatology in AN with re-nutrition. But, to our knowledge, no work has examined the evolution of social phobia symptoms during re-nutrition in AN. To specify the links between AN, nutritional state, and social phobia. The population consisted of 2 samples and the analysis was conducted using the SPSS11.5. Sample 1 (N=24 AN) was evaluated on admission and on leaving the hospital. Our evaluation used the body mass index (BMI), the Liebowitz scale, the Mini International Neuropsychiatric Interview (MINI), and the Yale-Brown Obsessive Compulsive Scale for Eating Disorders scale (Y-BOCS-ED) respectively to evaluate or diagnose the state of malnutrition, social anxiety symptomatology, social phobia in Diagnostic and Statistical Manual-4 (DSM-IV) and anorexic symptomatology. Sample 2 (N=60) was assessed at the end of the hospitalization and then 6, 12 and 18 months later. We used the BMI, Liebowitz scale, MINI, and Eating Disorders Inventory (EDI) to assess anorexic symptomatology. In addition, the Morgan-Russell outcome assessment schedule (MR schedule) was used to assess the total clinical state of the patients. Social anxiety symptomatology and actual diagnosis decreased throughout the treatment. However, regardless of the point at which the patient received care, there was no correlation between social phobia and nutritional state, as indicated by BMI. A correlation existed between social phobia and AN symptomatology, and between social phobia and total clinical state, during the out-patient care. A component of AN-social phobia comorbidity is still questionable. Is it linked to the clinical state of the subjects (question of an additional effect of under nutrition and cognition), or even to AN? Others indicators of under nutrition are of interest and warrant further evaluations. We therefore feel that a diagnosis of social phobia can only be confirmed after an acute state of AN, thus allowing for preferential treatments. Others studies must be conducted in order to continue to explore the links between social phobia and AN.

  5. A computational model to compare different investment scenarios for mini-stereotactic frame approach to deep brain stimulation surgery.

    PubMed

    Lanotte, M; Cavallo, M; Franzini, A; Grifi, M; Marchese, E; Pantaleoni, M; Piacentino, M; Servello, D

    2010-09-01

    Deep brain stimulation (DBS) alleviates symptoms of many neurological disorders by applying electrical impulses to the brain by means of implanted electrodes, generally put in place using a conventional stereotactic frame. A new image guided disposable mini-stereotactic system has been designed to help shorten and simplify DBS procedures when compared to standard stereotaxy. A small number of studies have been conducted which demonstrate localization accuracies of the system similar to those achievable by the conventional frame. However no data are available to date on the economic impact of this new frame. The aim of this paper was to develop a computational model to evaluate the investment required to introduce the image guided mini-stereotactic technology for stereotactic DBS neurosurgery. A standard DBS patient care pathway was developed and related costs were analyzed. A differential analysis was conducted to capture the impact of introducing the image guided system on the procedure workflow. The analysis was carried out in five Italian neurosurgical centers. A computational model was developed to estimate upfront investments and surgery costs leading to a definition of the best financial option to introduce the new frame. Investments may vary from Euro 1.900 (purchasing of Image Guided [IG] mini-stereotactic frame only) to Euro 158.000.000. Moreover the model demonstrates how the introduction of the IG mini-stereotactic frame doesn't substantially affect the DBS procedure costs.

  6. Superficial venous incompetence: low-cost outpatient minisurgery, sclerotherapy and combined procedure as a management plan. Costs and efficacy. A 20-year, follow-up registry.

    PubMed

    Belcaro, Gianni; Dugall, Mark; Corsi, Marcello; Agus, Giovanni B; Ippolito, Edmondo

    2016-08-01

    This registry study evaluated low-cost outpatient surgery (mini-S) for venous insufficiency as an alternative to stripping. This 20-year follow-up is focused on the recurrence of varices and on the long-term efficacy of the mini-S (group 1) in comparison with controls (2, stripping), sclerotherapy (3) or a combination of mini-S+sclerotherapy (4). Costs were compared. At 20-years of follow-up, considering recurrence/development of new varicose veins, 24.05% of the limbs treated with mini-S developed new varices in comparison with 64.4% in group 2, 24.1% in group 3 and 15.4% in group 4 (P<0.05). New surgical procedures were needed in 18.9% of mini-S patients vs. 58.5% in group 2, 21.9% in group 3 and 19.7% in group 4 (P<0.05 between group 2 and the other groups). Sclerotherapy (in the years following the initial treatment) was used in 37.9% of mini-S patients in comparison with 67.7% of subjects in group 2 patients, 33.1% in group 3 and 22.8% in group 4 (P<0.05 between outpatient treatment and group 2). The superficial venous system was incompetent in 21% of mini-S patients in comparison with 38.8% in group 2 (P<0.05), 20.7% in group 3 and 17.9% of group 4. At 20 years edema was present in 10.5% of limbs in group 2 in comparison with a <3% (range 2.2-2.1%) in the other groups. Edema was more significant after stripping. Ambulatory venous pressure measurements in subgroups was lower in groups 1, 3 and 4 with a lower refilling time (P<0.05). The cost of in-hospital, daily surgical treatments were €1978 (covered by the heathcare provider). The cost of mini-S was on average €488 per limb (covered by patients). Outpatients procedures, in particular the mini-S management plan, were cheaper than stripping and more effective at 20-years follow-up. They could be a model for emerging contries with restricted budgets for vein surgery. Also being cheaper more people may have benefits from treatment when/where hospital procedures are not covered by an healthcare provider.

  7. Two distinct classes of degenerative change are independently linked to clinical progression in mild cognitive impairment.

    PubMed

    Coutu, Jean-Philippe; Lindemer, Emily R; Konukoglu, Ender; Salat, David H

    2017-06-01

    We previously demonstrated 2 statistically distinct factors of degeneration in Alzheimer's disease: one strongly related to white matter damage and age interpreted as "age- and vascular-related", and the other related to cortical atrophy thought to represent "neurodegenerative changes associated with Alzheimer's disease". Those factors are now replicated in a distinct cross-sectional data set of 364 participants from the Alzheimer's Disease Neuroimaging Initiative and their interpretation is improved using correlations with CSF biomarkers. Furthermore, we now show that changes in both factors over 2 years are independently associated with decline in Mini-Mental State Examination score in a longitudinal subset of 116 individuals with mild cognitive impairment. Progression in the "age- and vascular-related" factor was greater for individuals with 2 APOE ε4 alleles and linked to a greater attributable change in Mini-Mental State Examination than the "neurodegenerative" factor. These results suggest benefits of targeting white matter and vascular health to complement interventions focused on the neurodegenerative aspect of the disease, even in individuals with little discernable vascular comorbidity. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Collagen scaffolds combined with collagen-binding ciliary neurotrophic factor facilitate facial nerve repair in mini-pigs.

    PubMed

    Lu, Chao; Meng, Danqing; Cao, Jiani; Xiao, Zhifeng; Cui, Yi; Fan, Jingya; Cui, Xiaolong; Chen, Bing; Yao, Yao; Zhang, Zhen; Ma, Jinling; Pan, Juli; Dai, Jianwu

    2015-05-01

    The preclinical studies using animal models play a very important role in the evaluation of facial nerve regeneration. Good models need to recapitulate the distance and time for axons to regenerate in humans. Compared with the most used rodent animals, the structure of facial nerve in mini-pigs shares more similarities with humans in microanatomy. To evaluate the feasibility of repairing facial nerve defects by collagen scaffolds combined with ciliary neurotrophic factor (CNTF), 10-mm-long gaps were made in the buccal branch of mini-pigs' facial nerve. Three months after surgery, electrophysiological assessment and histological examination were performed to evaluate facial nerve regeneration. Immunohistochemistry and transmission electron microscope observation showed that collagen scaffolds with collagen binding (CBD)-CNTF could promote better axon regeneration, Schwann cell migration, and remyelination at the site of implant device than using scaffolds alone. Electrophysiological assessment also showed higher recovery rate in the CNTF group. In summary, combination of collagen scaffolds and CBD-CNTF showed promising effects on facial nerve regeneration in mini-pig models. © 2014 Wiley Periodicals, Inc.

  9. Control of large flexible structures - An experiment on the NASA Mini-Mast facility

    NASA Technical Reports Server (NTRS)

    Hsieh, Chen; Kim, Jae H.; Liu, Ketao; Zhu, Guoming; Skelton, Robert E.

    1991-01-01

    The output variance constraint controller design procedure is integrated with model reduction by modal cost analysis. A procedure is given for tuning MIMO controller designs to find the maximal rms performance of the actual system. Controller designs based on a finite-element model of the system are compared with controller designs based on an identified model (obtained using the Q-Markov Cover algorithm). The identified model and the finite-element model led to similar closed-loop performance, when tested in the Mini-Mast facility at NASA Langley.

  10. A Measurement of the muon neutrino charged current quasielastic interaction and a test of Lorentz violation with the MiniBooNE experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katori, Teppei

    2008-12-01

    The Mini-Booster neutrino experiment (MiniBooNE) at Fermi National Accelerator Laboratory (Fermilab) is designed to search for v μ → v e appearance neutrino oscillations. Muon neutrino charged-current quasi-elastic (CCQE) interactions (v μ + n → μ + p) make up roughly 40% of our data sample, and it is used to constrain the background and cross sections for the oscillation analysis. Using high-statistics MiniBooNE CCQE data, the muon-neutrino CCQE cross section is measured. The nuclear model is tuned precisely using the MiniBooNE data. The measured total cross section is σ = (1.058 ± 0.003 (stat) ± 0.111 (syst)) x 10more » -38 cm 2 at the MiniBooNE muon neutrino beam energy (700-800 MeV). v e appearance candidate data is also used to search for Lorentz violation. Lorentz symmetry is one of the most fundamental symmetries in modern physics. Neutrino oscillations offer a new method to test it. We found that the MiniBooNE result is not well-described using Lorentz violation, however further investigation is required for a more conclusive result.« less

  11. Porcine (Sus scrofa) Chronic Myocardial Infarction Model Development

    DTIC Science & Technology

    2015-04-03

    Change from 8 mini pigs to 6 farm pigs and 2 mini pigs 3 Personnel added: Southard, Riddock 4 Personnel added: Julian 2 FDGXXX 6. FUNDING...models. Methods: Eight Yucatan miniature pigs underwent percutaneous embolization of the D1-LAD via injection of 90 µm polystyrene micro-spheres...myocardial structure and extracellular matrix composition respectively. Results: Overall procedural survival rate was 83% (5/6) with one pig

  12. A Comparison between the Effects of Aerobic Dance Training on Mini-Trampoline and Hard Wooden Surface on Bone Resorption, Health-Related Physical Fitness, Balance, and Foot Plantar Pressure in Thai Working Women.

    PubMed

    Sukkeaw, Wittawat; Kritpet, Thanomwong; Bunyaratavej, Narong

    2015-09-01

    To compare the effects of aerobic dance training on mini-trampoline and hard wooden surface on bone resorption, health-related physical fitness, balance, and foot plantar pressure in Thai working women. Sixty-three volunteered females aged 35-45 years old participated in the study and were divided into 3 groups: A) aerobic dance on mini-trampoline (21 females), B) aerobic dance on hard wooden surface (21 females), and C) control group (21 females). All subjects in the aerobic dance groups wore heart rate monitors during exercise. Aerobic dance worked out 3 times a week, 40 minutes a day for 12 weeks. The intensity was set at 60-80% of the maximum heart rate. The control group engaged in routine physical activity. The collected data were bone formation (N-terminal propeptine of procollagen type I: P1NP) bone resorption (Telopeptide cross linked: β-CrossLaps) health-related physical fitness, balance, and foot plantar pressure. The obtained data from pre- and post trainings were compared and analyzed by paired samples t-test and one way analysis of covariance. The significant difference was at 0.05 level. After the 12-week training, the biochemical bone markers of both mini-trampoline and hard wooden surface aerobic dance training subjects decreased in bone resorption (β-CrossLaps) but increased in boneformation (P1NP). Health-related physical fitness, balance, and foot plantar pressure were not only better when comparing to the pre-test result but also significantly different when comparing to the control group (p < 0.05). The aerobic dance on mini-trampoline showed that leg muscular strength, balance and foot plantar pressure were significantly better than the aerobic dance on hard wooden surface (p < 0.05). The aerobic dance on mini-trampoline and hard wooden surface had positive effects on biochemical bone markers. However, the aerobic dance on mini-trampoline had more leg muscular strength and balance including less foot plantar pressure. It is considered to be an appropriate exercise programs in working women.

  13. Mini-batch optimized full waveform inversion with geological constrained gradient filtering

    NASA Astrophysics Data System (ADS)

    Yang, Hui; Jia, Junxiong; Wu, Bangyu; Gao, Jinghuai

    2018-05-01

    High computation cost and generating solutions without geological sense have hindered the wide application of Full Waveform Inversion (FWI). Source encoding technique is a way to dramatically reduce the cost of FWI but subject to fix-spread acquisition setup requirement and slow convergence for the suppression of cross-talk. Traditionally, gradient regularization or preconditioning is applied to mitigate the ill-posedness. An isotropic smoothing filter applied on gradients generally gives non-geological inversion results, and could also introduce artifacts. In this work, we propose to address both the efficiency and ill-posedness of FWI by a geological constrained mini-batch gradient optimization method. The mini-batch gradient descent optimization is adopted to reduce the computation time by choosing a subset of entire shots for each iteration. By jointly applying the structure-oriented smoothing to the mini-batch gradient, the inversion converges faster and gives results with more geological meaning. Stylized Marmousi model is used to show the performance of the proposed method on realistic synthetic model.

  14. Experiments in advanced control concepts for space robotics - An overview of the Stanford Aerospace Robotics Laboratory

    NASA Technical Reports Server (NTRS)

    Hollars, M. G.; Cannon, R. H., Jr.; Alexander, H. L.; Morse, D. F.

    1987-01-01

    The Stanford University Aerospace Robotics Laboratory is actively developing and experimentally testing advanced robot control strategies for space robotic applications. Early experiments focused on control of very lightweight one-link manipulators and other flexible structures. The results are being extended to position and force control of mini-manipulators attached to flexible manipulators and multilink manipulators with flexible drive trains. Experimental results show that end-point sensing and careful dynamic modeling or adaptive control are key to the success of these control strategies. Free-flying space robot simulators that operate on an air cushion table have been built to test control strategies in which the dynamics of the base of the robot and the payload are important.

  15. Model validations for low-global warming potential refrigerants in mini-split air-conditioning units

    DOE PAGES

    Shen, Bo; Shrestha, Som; Abdelaziz, Omar

    2016-09-02

    To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition,more » the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.« less

  16. Model validations for low-global warming potential refrigerants in mini-split air-conditioning units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Shrestha, Som; Abdelaziz, Omar

    To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition,more » the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.« less

  17. Social media and college student risk behaviors: A mini-review.

    PubMed

    Groth, Gabrielle G; Longo, Laura M; Martin, Jessica L

    2017-02-01

    Use of social media use is widespread and frequent among college students. Posting photos and text related to risk behaviors (e.g., problematic alcohol use, illicit drug use) on social media websites is common and has been linked to personal substance use and negative outcomes. This mini-review summarizes current findings related to associations between college students' social media use and engagement in risk behaviors. Conducting research on social media poses unique challenges for researchers; these challenges are reviewed and their impact on the state of the current literature discussed. Finally, implications for prevention and intervention efforts are discussed as well as recommendations regarding future research in the area of social media and college student risk behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Fast-flowering mini-maize: seed to seed in 60 days

    USDA-ARS?s Scientific Manuscript database

    Two lines of Zea mays were developed as a short-generation model for maize. The Fast-Flowering Mini-Maize (FFMM) lines A and B are robust inbred lines with a significantly shorter generation time, much smaller stature, and better greenhouse adaptation than traditional maize varieties. Five generatio...

  19. Seed Embryo Development Is Regulated via an AN3-MINI3 Gene Cascade

    PubMed Central

    Meng, Lai-Sheng; Wang, Yi-Bo; Loake, Gary J.; Jiang, Ji-Hong

    2016-01-01

    In agriculture, seed mass is one of the most important components related to seed yield. MINISEED3 (MINI3) which encodes the transcriptional activator WRKY10, is thought to be a pivotal regulator of seed mass. In Arabidopsis SHORT HYPOCOTYL UNDER BLUE1 (SHB1) associates with the promoter of MINI3, regulating embryo cell proliferation (both cell division and elongation), which, in turn, modulates seed mass. Furthermore, the recruitment of SHB1 via MINI3 to both its cognate promoter and that of IKU2 implies a two-step amplification for countering the low expression level of IKU2, which is thought to function as a molecular switch for seed cavity enlargement. However, it is largely unknown how embryo cell proliferation, which encompasses both cell division and elongation, is regulated by SHB1 and MINI3 function. Here, we show that a loss of function mutation within the transcriptional coactivator ANGUSTIFOLIA3 (AN3), increases seed mass. Further, AN3 associates with the MINI3 promoter in vivo. Genetic evidence indicates that the absence of MINI3 function suppresses the decrease of cell number observed in an3-4 mutants by regulating cell division and in turn inhibits increased cell size of the an3-4 line by controlling cell elongation. Thus, seed embryo development is modulated via an AN3-MINI3 gene cascade. This regulatory model provides a deeper understanding of seed mass regulation, which may in turn lead to increased crop yields. PMID:27857719

  20. Introduction: Why Link Indigenous Ways of Knowing with the Teaching of Environmental Studies and Sciences?

    ERIC Educational Resources Information Center

    Rich, Nancy

    2012-01-01

    This paper introduces a mini-symposium on bringing Indigenous ways of knowing together with the teaching of environmental studies and sciences (ESS). Both knowledges share a fundamental interest in the relationship of humans with the Earth, yet until recently, Indigenous ways of knowing have rarely been visible in the teaching of ESS. Teaching…

  1. Investigations & Casualty Analysis « Coast Guard Maritime Commons

    Science.gov Websites

    marine casualty reporting property damage thresholds now in effect This post provides links to updated : This post was updated April 10, 2018 to reflect that Inmarsat will begin the migration 1400 UTC May 9 website provided in our blog post. Inmarsat announced that it will migrate Inmarsat-C, Mini C, and Fleet77

  2. Vitamin B-12 and folate status in relation to decline in scores on the Mini-Mental State Examination in the Framingham Heart Study

    USDA-ARS?s Scientific Manuscript database

    Biochemical evidence of low vitamin B-12 status is common in seniors, but its clinical relevance is unclear. Vitamin B-12 deficiency can result in rapid, irreversible cognitive decline – a phenomenon that has been linked to high folate status. Our objective was to investigate the cognitive significa...

  3. Function and structure in social brain regions can link oxytocin-receptor genes with autistic social behavior.

    PubMed

    Yamasue, Hidenori

    2013-02-01

    Difficulties in appropriate social and communicative behaviors are the most prevalent and core symptoms of autism spectrum disorders (ASDs). Although recent intensive research has focused on the neurobiological background of these difficulties, many aspects of them were not yet elucidated. Recent studies have employed multimodal magnetic resonance imaging (MRI) indices as intermediate phenotypes of this behavioral phenotype to link candidate genes with the autistic social difficulty. As MRI indices, functional MRI (fMRI), structural MRI, and MR-spectroscopy have been examined in subjects with autism spectrum disorders. As candidate genes, this mini-review has much interest in oxytocin-receptor genes (OXTR), since recent studies have repeatedly reported their associations with normal variations in social cognition and behavior as well as with their extremes, autistic social dysfunction. Through previous increasing studies, medial prefrontal cortex, hypothalamus and amygdala have repeatedly been revealed as neural correlates of autistic social behavior by MRI multimodalities and their relationship to OXTR. For further development of this research area, this mini-review integrates recent accumulating evidence about human behavioral and neural correlates of OXTR. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  4. Armed oncolytic adenovirus expressing PD-L1 mini-body enhances anti-tumor effects of chimeric antigen receptor T-cells in solid tumors

    PubMed Central

    Tanoue, Kiyonori; Shaw, Amanda Rosewell; Watanabe, Norihiro; Porter, Caroline; Rana, Bhakti; Gottschalk, Stephen; Brenner, Malcolm; Suzuki, Masataka

    2017-01-01

    Chimeric antigen receptor-modified T cells (CAR T-cells) produce pro-inflammatory cytokines that increase expression of T cell checkpoint signals such as PD-L1, which may inhibit their functionality against solid tumors. In this study, we evaluated in human tumor xenograft models the pro-inflammatory properties of an oncolytic adenovirus (Onc.Ad) with a helper-dependent Ad (HDAd) that expresses a PD-L1 blocking mini-antibody (mini-body) (HDPDL1), as a strategy to enhance CAR T-cell killing. Co-administration of these agents (CAd-VECPDL1) exhibited oncolytic effects with production of PD-L1 mini-body locally at the tumor site. On their own, HDPDL1 exhibited no anti-tumor effect and CAd-VECPDL1 alone reduced tumors only to volumes comparable to Onc.Ad treatment. However, combining CAd-VECPDL1 with HER2.CAR T-cells enhanced anti-tumor activity compared to treatment with either HER2.CAR T-cells alone, or HER2.CAR T-cells plus Onc.Ad. The benefits of locally produced PD-L1 mini-body by CAd-VECPDL1 could not be replicated by infusion of anti-PD-L1 IgG plus HER2.CAR T-cells and co-administration of Onc.Ad in a HER2+ prostate cancer xenograft model. Overall, our data document the superiority of local production of PD-L1 mini-body by CAd-VECPDL1 combined with administration of tumor-directed CAR T-cells to control the growth of solid tumors. PMID:28235763

  5. Resilient Energy Systems | Integrated Energy Solutions | NREL

    Science.gov Websites

    of microgrids Business model and valuation analysis for resilience Photovoltaic plus storage analysis Framework for Mini-Grids NREL has teamed with the Global Lighting and Energy Access Partnership and the U.S mini-grids. NREL Enhances Energy Resiliency at Marine Corps Air Station Miramar NREL has partnered with

  6. Mini Versus Standard Percutaneous Nephrolithotomy: The Impact of Sheath Size on Intrarenal Pelvic Pressure and Infectious Complications in a Porcine Model.

    PubMed

    Loftus, Christopher J; Hinck, Bryan; Makovey, Iryna; Sivalingam, Sri; Monga, Manoj

    2018-04-01

    To determine how sheath and endoscope size affect intrarenal pelvic pressures and risk of postoperative infectious complications comparing "Mini" vs "Standard" percutaneous nephrolithotomy (PCNL). Uropathogenic Escherichia coli were grown and 10 9 of them were instilled into the porcine renal pelvis through retrograde access for 1 hour. Percutaneous access utilized a 14/16F 20 cm ureteral access sheath for the Mini arm and a 30F sheath for the Standard arm. Nephroscopy was simulated utilizing either an 8/9.8F semirigid ureteroscope or 26F nephroscope for 1 hour while intrarenal pelvic pressure was continuously monitored. Blood and tissue cultures of kidney, liver, and spleen biopsies were plated and incubated and positive cultures were confirmed with polymerase chain reaction. Intrapelvic pressures were higher in the Mini group, 18.76 ± 5.82 mm Hg vs 13.56 ± 5.82 mm Hg (p < 0.0001). Time spent above 30 mm Hg was greater in the Mini arm, 117.0 seconds vs 66.1 seconds (p = 0.0452). All pigs had positive kidney tissue cultures whereas spleen cultures were positive in 100% and 60% of pigs in the Mini and Standard arms, respectively (p = 0.0253); 90% and 30% had positive liver tissue culture in the Mini and Standard arms, respectively (p = 0.0062). Blood cultures were positive in 30% of pigs in the Mini arm compared with none in the Standard arm (p = 0.0603). Mini-PCNL was associated with higher intrarenal pressures and higher risk of end organ bacterial seeding in the setting of an infected collecting system. This suggests a higher potential for infectious complications in a clinical setting.

  7. Fast-Flowering Mini-Maize: Seed to Seed in 60 Days

    PubMed Central

    McCaw, Morgan E.; Wallace, Jason G.; Albert, Patrice S.; Buckler, Edward S.; Birchler, James A.

    2016-01-01

    Two lines of Zea mays were developed as a short-generation model for maize. The Fast-Flowering Mini-Maize (FFMM) lines A and B are robust inbred lines with a significantly shorter generation time, much smaller stature, and better greenhouse adaptation than traditional maize varieties. Five generations a year are typical. FFMM is the result of a modified double-cross hybrid between four fast-flowering lines: Neuffer’s Early ACR (full color), Alexander’s Early Early Synthetic, Tom Thumb Popcorn, and Gaspe Flint, followed by selection for early flowering and desirable morphology throughout an 11-generation selfing regime. Lines A and B were derived from different progeny of the initial hybrid, and crosses between Mini-Maize A and B exhibit heterosis. The ancestry of each genomic region of Mini-Maize A and B was inferred from the four founder populations using genotyping by sequencing. Other genetic and genomic tools for these lines include karyotypes for both lines A and B, kernel genetic markers y1 (white endosperm) and R1-scm2 (purple endosperm and embryo) introgressed into Mini-Maize A, and ∼24× whole-genome resequencing data for Mini-Maize A. PMID:27440866

  8. From ozone mini-holes and mini-highs towards extreme value theory: New insights from extreme events and non-stationarity

    NASA Astrophysics Data System (ADS)

    Rieder, H. E.; Staehelin, J.; Maeder, J. A.; Ribatet, M.; Stübi, R.; Weihs, P.; Holawe, F.; Peter, T.; Davison, A. C.

    2009-04-01

    Over the last few decades negative trends in stratospheric ozone have been studied because of the direct link between decreasing stratospheric ozone and increasing surface UV-radiation. Recently a discussion on ozone recovery has begun. Long-term measurements of total ozone extending back earlier than 1958 are limited and only available from a few stations in the northern hemisphere. The world's longest total ozone record is available from Arosa, Switzerland (Staehelin et al., 1998a,b). At this site total ozone measurements have been made since late 1926 through the present day. Within this study (Rieder et al., 2009) new tools from extreme value theory (e.g. Coles, 2001; Ribatet, 2007) are applied to select mathematically well-defined thresholds for extreme low and extreme high total ozone. A heavy-tail focused approach is used by fitting the Generalized Pareto Distribution (GPD) to the Arosa time series. Asymptotic arguments (Pickands, 1975) justify the use of the GPD for modeling exceedances over a sufficiently high (or below a sufficiently low) threshold (Coles, 2001). More precisely, the GPD is the limiting distribution of normalized excesses over a threshold, as the threshold approaches the endpoint of the distribution. In practice, GPD parameters are fitted, to exceedances by maximum likelihood or other methods - such as the probability weighted moments. A preliminary step consists in defining an appropriate threshold for which the asymptotic GPD approximation holds. Suitable tools for threshold selection as the MRL-plot (mean residual life plot) and TC-plot (stability plot) from the POT-package (Ribatet, 2007) are presented. The frequency distribution of extremes in low (termed ELOs) and high (termed EHOs) total ozone and their influence on the long-term changes in total ozone are analyzed. Further it is shown that from the GPD-model the distribution of so-called ozone mini holes (e.g. Bojkov and Balis, 2001) can be precisely estimated and that the "extremes concept" provides new information on the data distribution and variability within the Arosa record as well as on the influence of ELOs and EHOs on the long-term trends of the ozone time series. References: Bojkov, R. D., and Balis, D.S.: Characteristics of episodes with extremely low ozone values in the northern middle latitudes 1975-2000, Ann. Geophys., 19, 797-807, 2001. Coles, S.: An Introduction to Statistical Modeling of Extreme Values, Springer Series in Statistics, ISBN:1852334592, Springer, Berlin, 2001. Pickands, J.: Statistical inference using extreme order statistics, Ann. Stat., 3, 1, 119-131, 1975. Ribatet, M.: POT: Modelling peaks over a threshold, R News, 7, 34-36, 2007. Rieder, H.E., Staehelin, J., Maeder, J.A., Stübi, R., Weihs, P., Holawe, F., and M. Ribatet: From ozone mini holes and mini highs towards extreme value theory: New insights from extreme events and non stationarity, submitted to J. Geophys. Res., 2009. Staehelin, J., Kegel, R., and Harris, N. R.: Trend analysis of the homogenized total ozone series of Arosa (Switzerland), 1929-1996, J. Geophys. Res., 103(D7), 8389-8400, doi:10.1029/97JD03650, 1998a. Staehelin, J., Renaud, A., Bader, J., McPeters, R., Viatte, P., Hoegger, B., Bugnion, V., Giroud, M., and Schill, H.: Total ozone series at Arosa (Switzerland): Homogenization and data comparison, J. Geophys. Res., 103(D5), 5827-5842, doi:10.1029/97JD02402, 1998b.

  9. The Psychometrics of the Mini-K.

    PubMed

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  10. An anthropological approach to teach and evaluate cultural competence in medical students - the application of mini-ethnography in medical history taking.

    PubMed

    Hsieh, Jyh-Gang; Hsu, Mutsu; Wang, Ying-Wei

    2016-01-01

    Purpose To use mini-ethnographies narrating patient illness to improve the cultural competence of the medical students. Methods Between September 2013 and June 2015, all sixth-year medical students doing their internship at a medical center in eastern Taiwan were trained to write mini-ethnographies for one of the patients in their care. The mini-ethnographies were analyzed by authors with focus on the various aspects of cultural sensitivity and a holistic care approach. Results Ninety-one students handed in mini-ethnographies, of whom 56 were male (61.5%) and 35 were female (38.5%). From the mini-ethnographies, three core aspects were derived: 1) the explanatory models and perceptions of illness, 2) culture and health care, and 3) society, resources, and health care. Based on the qualities of each aspect, nine secondary nodes were classified: expectations and attitude about illness/treatment, perceptions about their own prognosis in particular, knowledge and feelings regarding illness, cause of illness, choice of treatment method (including traditional medical treatments), prejudice and discrimination, influences of traditional culture and language, social support and resources, and inequality in health care. Conclusions Mini-ethnography is an effective teaching method that can help students to develop cultural competence. It also serves as an effective instrument to assess the cultural competence of medical students.

  11. The efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant-a finite element study.

    PubMed

    Moon, Won; Wu, Kimberley W; MacGinnis, Matthew; Sung, Jay; Chu, Howard; Youssef, George; Machado, Andre

    2015-01-01

    Maxillary protraction with the novel N2 mini-implant- and micro-implant-assisted rapid palatal expander (MARPE) can potentially provide significant skeletal effects without surgery, even in older patients where conventional facemask therapy has limited skeletal effects. However, the skeletal effects of altering the location and direction of force from mini-implant-assisted maxillary protraction have not been extensively analyzed. In this study, the application of the novel N2 mini-implant as an orthopedic anchorage device is explored in its ability to treat patients with class III malocclusions. A 3D cranial mesh model with associated sutures was developed from CT images and Mimics modeling software. Utilizing ANSYS simulation software, protraction forces were applied at different locations and directions to simulate conventional facemask therapy and seven maxillary protraction protocols utilizing the novel N2 mini-implant. Stress distribution and displacement were analyzed. Video animations and superimpositions were created. By changing the vector of force and location of N2 mini-implant, the maxilla was displaced differentially. Varying degrees of forward, downward, and rotational movements were observed in each case. For brachyfacial patients, anterior micro-implant-supported protraction at -45° or intermaxillary class III elastics at -45° are recommended. For dolicofacial patients, either anterior micro-implants at -15° or an intermaxillary spring at +30° is recommended. For mesofacial patients with favorable vertical maxillary position, palatal micro-implants at -30° are recommended; anterior micro-implants at -30° are preferred for shallow bites. For patients with a severe mid-facial deficiency, intermaxillary class III elastics at -30° are most effective in promoting anterior growth of the maxilla. By varying the location of N2 mini-implants and vector of class III mechanics, clinicians can differentially alter the magnitude of forward, downward, and rotational movement of the maxilla. As a result, treatment protocol can be customized for each unique class III patient.

  12. Nus and anti-nus from MiniBooNE: searching for the shadow of the ghost

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, Geoffrey B

    2009-01-01

    The latest results from MiniBooNE, the short baseline neutrino experiment operating on the 8 GeV booster's neutrino beam line (the BNB) at Fermilab, are discussed. The standard three active generation model of neutrino oscillations is now grounded firmly by experimental data. Studying the properties of neutrinos at the few percent level and below may uncover new properties of neutrinos and their oscillations and provide a path to physics beyond the standard neutrino model.

  13. Earth Observations taken by Expedition 30 crewmember

    NASA Image and Video Library

    2011-12-31

    ISS030-E-038578 (31 Dec. 2011) --- Clouds form the backdrop for this scene photographed by one of the Expedition 30 crew members aboard the International Space Station, with two Russian spacecraft docked to the orbital outpost. A Soyuz (near foreground) is docked to Rassvet, also known as the Mini-Research Module 1 (MRM-1), and a Progress is linked to the Pirs Docking Compartment.

  14. Evolution of a mini-scale biphasic dissolution model: Impact of model parameters on partitioning of dissolved API and modelling of in vivo-relevant kinetics.

    PubMed

    Locher, Kathrin; Borghardt, Jens M; Frank, Kerstin J; Kloft, Charlotte; Wagner, Karl G

    2016-08-01

    Biphasic dissolution models are proposed to have good predictive power for the in vivo absorption. The aim of this study was to improve our previously introduced mini-scale dissolution model to mimic in vivo situations more realistically and to increase the robustness of the experimental model. Six dissolved APIs (BCS II) were tested applying the improved mini-scale biphasic dissolution model (miBIdi-pH-II). The influence of experimental model parameters including various excipients, API concentrations, dual paddle and its rotation speed was investigated. The kinetics in the biphasic model was described applying a one- and four-compartment pharmacokinetic (PK) model. The improved biphasic dissolution model was robust related to differing APIs and excipient concentrations. The dual paddle guaranteed homogenous mixing in both phases; the optimal rotation speed was 25 and 75rpm for the aqueous and the octanol phase, respectively. A one-compartment PK model adequately characterised the data of fully dissolved APIs. A four-compartment PK model best quantified dissolution, precipitation, and partitioning also of undissolved amounts due to realistic pH profiles. The improved dissolution model is a powerful tool for investigating the interplay between dissolution, precipitation and partitioning of various poorly soluble APIs (BCS II). In vivo-relevant PK parameters could be estimated applying respective PK models. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A simple eccentric stirred tank mini-bioreactor: mixing characterization and mammalian cell culture experiments.

    PubMed

    Bulnes-Abundis, David; Carrillo-Cocom, Leydi M; Aráiz-Hernández, Diana; García-Ulloa, Alfonso; Granados-Pastor, Marisa; Sánchez-Arreola, Pamela B; Murugappan, Gayathree; Alvarez, Mario M

    2013-04-01

    In industrial practice, stirred tank bioreactors are the most common mammalian cell culture platform. However, research and screening protocols at the laboratory scale (i.e., 5-100 mL) rely primarily on Petri dishes, culture bottles, or Erlenmeyer flasks. There is a clear need for simple-easy to assemble, easy to use, easy to clean-cell culture mini-bioreactors for lab-scale and/or screening applications. Here, we study the mixing performance and culture adequacy of a 30 mL eccentric stirred tank mini-bioreactor. A detailed mixing characterization of the proposed bioreactor is presented. Laser induced fluorescence (LIF) experiments and computational fluid dynamics (CFD) computations are used to identify the operational conditions required for adequate mixing. Mammalian cell culture experiments were conducted with two different cell models. The specific growth rate and the maximum cell density of Chinese hamster ovary (CHO) cell cultures grown in the mini-bioreactor were comparable to those observed for 6-well culture plates, Erlenmeyer flasks, and 1 L fully instrumented bioreactors. Human hematopoietic stem cells were successfully expanded tenfold in suspension conditions using the eccentric mini-bioreactor system. Our results demonstrate good mixing performance and suggest the practicality and adequacy of the proposed mini-bioreactor. Copyright © 2012 Wiley Periodicals, Inc.

  16. The role of DSM-5 borderline personality symptomatology and traits in the link between childhood trauma and suicidal risk in psychiatric patients.

    PubMed

    Bach, Bo; Fjeldsted, Rita

    2017-01-01

    Childhood traumas appear to be linked to suicidal behavior. However, the factors that mediate between these two phenomena are not sufficiently understood. Recent findings suggest that borderline personality disorder (BPD) may explain some of the association. The present study investigated the potential mediating role of BPD symptomatology and traits between reported childhood trauma and suicidal risk in adult psychiatric outpatients ( N  = 124). BPD symptomatology was measured with DSM-5 Section II criterion-counts (SCID-II; Structured Clinical Interview for DSM-IV Axis II), whereas BPD traits were measured with specified DSM-5 Section III traits (PID-5; Personality Inventory for DSM-5). Childhood traumas were self-reported (CTQ; Childhood Trauma Questionnaire), whereas level of suicidal risk was measured with a structured interview (MINI Suicidality Module; Mini International Neuropsychiatric Interview). Mediation effects were tested by bias-corrected (10.000 boot-strapped samples) confidence intervals. BPD features account for a considerable part of the cross-sectional association between childhood trauma and level of suicidal risk, even when controlling for the influence of gender, age, and educational level. This finding remained stable when testing the model without the suicidality-related BPD criterion and PID-5 items. DSM-5 Section II BPD criterion-counts explained 67% of the total effect, whereas DSM-5 Section III BPD traits accounted for 82% of the total effect. The specific DSM-5 Section III trait facets of "Depressivity" (52%) and "Perceptual Dysregulation" (37%) accounted for most of this effect. The findings provide preliminary support for the proposed mediation model indicating that BPD features may help explain relations between childhood trauma and elevated suicidal risk in adult life, in particular for DSM-5 Section III personality traits of depressivity (e.g., pessimism, guilt, and shame) and perceptual dysregulation (e.g., dissociation). To reduce the suicidal risk among those with a history of childhood trauma, BPD features (including "Depressivity" and "Perceptual Dysregulation") might be an important target of assessment, risk management, and treatment. However, other factors are likely to be involved, and a longitudinal and more large-scale design is warranted for a conclusive test of mediation.

  17. Aspects on the design, implementation, and simulation of a tracked mini robot destined for special applications in theatres of operations

    NASA Astrophysics Data System (ADS)

    Petrişor, Silviu-Mihai; Bârsan, GhiÅ£Ä.ƒ

    2013-12-01

    The authors of this paper wish to highlight elements regarding the organology, functioning and simulation, in a real workspace, of a tracked mini robot structure destined for special applications in theatres of operation, a technological product which is subject to a national patent granted to our institution (patent no. RO a 2012 01051), the result of research activities undertaken under a contract won by national competition, a grant for young research teams, PN-RUTE- 2010 type. The issues outlined in this paper are aspects related to the original invention in comparison with other mini-robot structures, the inventors presenting succinctly the technological product description and its applicability both in the military and applicative area as well as in the educational one. Additionally, the advantages of using the technological product are shown in a real workspace, the constructive and functional solution before, finally, presenting, based on the modelling of the mechanical structure of the tilting module attached to the mini-robot, an application on the simulation and programming of the mini-robot under study.

  18. Use of Mini-Grant to Disseminate Evidence-Based Interventions for Cancer Prevention and Control.

    PubMed

    Kegler, Michelle C; Carvalho, Michelle L; Ory, Marcia; Kellstedt, Deb; Friedman, Daniela B; McCracken, James Lyndon; Dawson, Glenna; Fernandez, Maria

    2015-01-01

    Mini-grants are an increasingly common tool for engaging communities in evidence-based interventions for promoting public health. This article describes efforts by 4 Centers for Disease Control and Prevention/National Cancer Institute-funded Cancer Prevention and Control Research Network centers to design and implement mini-grant programs to disseminate evidence-based interventions for cancer prevention and control. This article also describes source of evidence-based interventions, funding levels, selection criteria, time frame, number and size of grants, types of organizations funded, selected accomplishments, training and technical assistance, and evaluation topics/methods. Grant size ranged from $1000 to $10 000 (median = $6250). This mini-grant opportunity was characterized by its emphasis on training and technical assistance for evidence-based programming and dissemination of interventions from National Cancer Institute's Research-Tested Intervention Programs and Centers for Disease Control and Prevention's Guide to Community Preventive Services. All projects had an evaluation component, although they varied in scope. Mini-grant processes described can serve as a model for organizations such as state health departments working to bridge the gap between research and practice.

  19. Pattern-oriented modelling: a ‘multi-scope’ for predictive systems ecology

    PubMed Central

    Grimm, Volker; Railsback, Steven F.

    2012-01-01

    Modern ecology recognizes that modelling systems across scales and at multiple levels—especially to link population and ecosystem dynamics to individual adaptive behaviour—is essential for making the science predictive. ‘Pattern-oriented modelling’ (POM) is a strategy for doing just this. POM is the multi-criteria design, selection and calibration of models of complex systems. POM starts with identifying a set of patterns observed at multiple scales and levels that characterize a system with respect to the particular problem being modelled; a model from which the patterns emerge should contain the right mechanisms to address the problem. These patterns are then used to (i) determine what scales, entities, variables and processes the model needs, (ii) test and select submodels to represent key low-level processes such as adaptive behaviour, and (iii) find useful parameter values during calibration. Patterns are already often used in these ways, but a mini-review of applications of POM confirms that making the selection and use of patterns more explicit and rigorous can facilitate the development of models with the right level of complexity to understand ecological systems and predict their response to novel conditions. PMID:22144392

  20. Does the design of mini slings anchoring systems really matter? A biomechanical comparison between Mini Arc™ and Ophira™.

    PubMed

    Santos-Souza, R; Rodrigues-Palma, P C; Goulart-Fernandes-Dias, F; Teixeira-Siniscalchi, R; Zanettini-Riccetto, C L

    2016-11-01

    Currently, a sling implant is the standard treatment for stress urinary incontinence in women. To be effective, they require an adequate anchoring system. The aim of this study is compare biomechanical features of fixation systems of two mini slings models available on the market (Ophira™ and Mini Arc™) through a tensile test. Anchoring devices of each sling were surgically implanted in abdominal wall of 15 rats divided into three groups of five animals which were arranged according to the date of post implant euthanasia on 7, 14 and 30 days. Abdominal walls of rats were extracted on bloc containing the anchoring system and were submitted to a tensile strength test to measure the maximum load and elongation until device avulsion from the tissue. The results were compared using Student test t and a 5% cut off was considered significant. The Ophira™ mini sling fixation system demanded a greater maximum load and developed a longer stretch for avulsion from the implanted site at all moments evaluated (p value less than 0.05). There were significant differences in fixation patterns of the anchoring systems, which were exclusively related to their designs. The Ophira™ mini sling fixation device provided better fixation to the abdominal wall of rats compared to the Mini Arc™ device, even in the late post implant period. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study.

    PubMed

    Matys, Jacek; Flieger, Rafał; Tenore, Gianluca; Grzech-Leśniak, Kinga; Romeo, Umberto; Dominiak, Marzena

    2018-04-01

    It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between - 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p < 0.05). The highest failure rate (33.3%) during mini-implant insertion was noted for self-drilling method (G4) as compared with G1, G2, and G3 groups (p < 0.05). The small diameter decortication by Er:YAG laser appeared to provide better primary stability as compared to drill and piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling method.

  2. A Randomised Control Trial of a Tier-2 Small-Group Intervention ("MiniLit") for Young Struggling Readers

    ERIC Educational Resources Information Center

    Buckingham, Jennifer; Wheldall, Kevin; Beaman, Robyn

    2012-01-01

    The response-to-intervention model is predicated upon increasingly intensive tiers of instruction. The aim of the present study was to examine the efficacy of a Tier-2 small-group literacy intervention ("MiniLit") designed for young readers who are still struggling after experiencing whole-class initial instruction. A total of 22…

  3. The Effect of Mini and Midi Anchor Tests on Test Equating

    ERIC Educational Resources Information Center

    Arikan, Çigdem Akin

    2018-01-01

    The main purpose of this study is to compare the test forms to the midi anchor test and the mini anchor test performance based on item response theory. The research was conducted with using simulated data which were generated based on Rasch model. In order to equate two test forms the anchor item nonequivalent groups (internal anchor test) was…

  4. Dual AAV therapy ameliorates exercise-induced muscle injury and functional ischemia in murine models of Duchenne muscular dystrophy.

    PubMed

    Zhang, Yadong; Yue, Yongping; Li, Liang; Hakim, Chady H; Zhang, Keqing; Thomas, Gail D; Duan, Dongsheng

    2013-09-15

    Neuronal nitric oxide synthase (nNOS) membrane delocalization contributes to the pathogenesis of Duchenne muscular dystrophy (DMD) by promoting functional muscle ischemia and exacerbating muscle injury during exercise. We have previously shown that supra-physiological expression of nNOS-binding mini-dystrophin restores normal blood flow regulation and prevents functional ischemia in transgenic mdx mice, a DMD model. A critical next issue is whether systemic dual adeno-associated virus (AAV) gene therapy can restore nNOS-binding mini-dystrophin expression and mitigate muscle activity-related functional ischemia and injury. Here, we performed systemic gene transfer in mdx and mdx4cv mice using a pair of dual AAV vectors that expressed a 6 kb nNOS-binding mini-dystrophin gene. Vectors were packaged in tyrosine mutant AAV-9 and co-injected (5 × 10(12) viral genome particles/vector/mouse) via the tail vein to 1-month-old dystrophin-null mice. Four months later, we observed 30-50% mini-dystrophin positive myofibers in limb muscles. Treatment ameliorated histopathology, increased muscle force and protected against eccentric contraction-induced injury. Importantly, dual AAV therapy successfully prevented chronic exercise-induced muscle force drop. Doppler hemodynamic assay further showed that therapy attenuated adrenergic vasoconstriction in contracting muscle. Our results suggest that partial transduction can still ameliorate nNOS delocalization-associated functional deficiency. Further evaluation of nNOS binding mini-dystrophin dual AAV vectors is warranted in dystrophic dogs and eventually in human patients.

  5. Attenuation of S. aureus-induced bacteremia by human mini-antibodies targeting the complement inhibitory protein Efb

    PubMed Central

    Georgoutsou-Spyridonos, Maria; Ricklin, Daniel; Pratsinis, Haris; Perivolioti, Eustathia; Pirmettis, Ioannis; Garcia, Brandon L.; Geisbrecht, Brian V.; Foukas, Periklis G.; Lambris, John D.; Mastellos, Dimitrios C.; Sfyroera, Georgia

    2015-01-01

    Staphylococcus aureus (S. aureus) can cause a broad range of potentially fatal inflammatory complications (e.g. sepsis, endocarditis). Its emerging antibiotic resistance and formidable immune evasion arsenal have emphasized the need for more effective antimicrobial approaches. Complement is an innate immune sensor that rapidly responds to bacterial infection eliciting C3-mediated opsonophagocytic and immunomodulatory responses. Extracellular Fibrinogen-binding Protein (Efb) is a key immune evasion protein of S. aureus that intercepts complement at the level of C3. To date, Efb has not been explored as a target for monoclonal antibody (mAb)-based antimicrobial therapeutics. Herein we have isolated donor-derived anti-Efb IgGs that attenuate S. aureus survival through enhanced neutrophil killing. A phage library screen yielded mAbs (miniAbs) that selectively inhibit the interaction of Efb with C3 partly by disrupting contacts essential for complex formation. Surface Plasmon Resonance-based kinetic analysis enabled the selection of miniAbs with favorable Efb-binding profiles as therapeutic leads. MiniAb-mediated blockade of Efb attenuated S aureus survival in a whole blood model of bacteremia. This neutralizing effect was associated with enhanced neutrophil-mediated killing of S. aureus, increased C5a release and modulation of IL-6 secretion. Finally, these miniAbs afforded protection from S. aureus-induced bacteremia in a murine renal abscess model, attenuating bacterial inflammation in kidneys. Overall, these findings are anticipated to pave the way towards novel antibody-based therapeutics for S. aureus-related diseases. PMID:26342032

  6. Effects of retraction force and anchorage reinforcement on occlusal force: a model study.

    PubMed

    Kim, MoonHee; Seol, Kyung-sim; Lee, Yoonjung; Park, Jiman; Kim, Minji; Chun, Youn-Sic

    2014-10-01

    The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. Occlusal forces were measured from this model, according to different retraction forces that were generated by elastic chain, under varied compressive forces (simulating masticatory forces). This retraction experiment was then performed again, after using anchorage reinforcement with an orthodontic mini implant. Occlusal force decreased as retraction force increased. The decrease showed a significant difference above 150g of retraction force (P < 0.05) and was more definite under compressive force higher than 150 N (P < 0.001). After anchorage reinforcement with the orthodontic mini implant, however, occlusal force did not significantly decrease with increasing retraction force. Significant differences in occlusal force were noted between the conditions with and without anchorage reinforcement when the applied retraction force was greater than 200g. Occlusal force tends to decrease during retraction, and this decrease can be prevented by anchorage reinforcement with orthodontic mini implants. Further investigation on the actual masticatory process in humans is required for more clear clinical implication. © The Author 2013. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. Mini-mast CSI testbed user's guide

    NASA Technical Reports Server (NTRS)

    Tanner, Sharon E.; Pappa, Richard S.; Sulla, Jeffrey L.; Elliott, Kenny B.; Miserentino, Robert; Bailey, James P.; Cooper, Paul A.; Williams, Boyd L., Jr.; Bruner, Anne M.

    1992-01-01

    The Mini-Mast testbed is a 20 m generic truss highly representative of future deployable trusses for space applications. It is fully instrumented for system identification and active vibrations control experiments and is used as a ground testbed at NASA-Langley. The facility has actuators and feedback sensors linked via fiber optic cables to the Advanced Real Time Simulation (ARTS) system, where user defined control laws are incorporated into generic controls software. The object of the facility is to conduct comprehensive active vibration control experiments on a dynamically realistic large space structure. A primary goal is to understand the practical effects of simplifying theoretical assumptions. This User's Guide describes the hardware and its primary components, the dynamic characteristics of the test article, the control law implementation process, and the necessary safeguards employed to protect the test article. Suggestions for a strawman controls experiment are also included.

  8. Alcohol consumption and prostate cancer: a mini review.

    PubMed

    Rizos, Ch; Papassava, M; Golias, Ch; Charalabopoulos, K

    2010-07-01

    Prostate cancer has become a major public health problem worldwide although the etiology of prostate cancer remains largely unknown. Dietary factors, dietary supplements, and physical activity might be important in the prevention of the disease. In the majority of studies published, it was observed that high consumption of meat, alcohol and dairy products has been linked to a greater risk. Specifically, alcohol use, and particularly heavy use, may cause cancers of liver, esophagus, larynx, pharynx and oral cavity, with risks for the aero-digestive cancers. Moderate use among women has been related with increases in breast cancer. Alcohol consumption is a modifiable lifestyle factor that may affect prostate cancer risk. Alcohol alters the hormonal environment and in parallel, containing chemical substances such as flavonoids (red wine), may alter tumor cell growth. In this mini review, the relation between alcohol consumption and prostate cancer risk is analyzed.

  9. Photograph use on social network sites among South Korean college students: the role of public and private self-consciousness.

    PubMed

    Shim, Minsun; Lee, Min Ju; Park, Sang Hee

    2008-08-01

    This study challenges theories of computer-mediated communication (CMC) that typically assume a lack of visual cues in CMC and conceptualize them as a situational factor. We examine individual differences in photo use on social network sites and link them to the dispositional tendency of self-consciousness (SC). Included were 231 students from one university in South Korea, who owned and maintained Cyworld profiles (called "mini-homepages"). Findings suggest that public SC, but not private SC, was positively associated with the higher frequency of posting photos, replying to comments on the photos, and scrapping photos on their mini-homepages. The frequency of posting specific content types of photos (concerning social relationships or life events) was also determined by participants' public SC but not by private SC. Implications of the findings for CMC theories are discussed.

  10. Using Cold-water Coral Mini-mounds as Analogue for Giant Mound Growth: Assessment of Environmental Drivers and Anthropogenic Impact

    NASA Astrophysics Data System (ADS)

    Collart, T.; Stewart, H. A.; Howell, K.; Bourillet, J. F.; Llave, E.; Blamart, D.; Mienis, F.; Van Rooij, D.

    2015-12-01

    Cold-water coral (CWC) reefs are formed by framework building scleratinians Lophelia pertusa and Madrepora oculata that baffle sediment and over time, have the potential to develop into large coral mounds of up to 300m high (e.g. Belgica Mound Province). The detailed mechanisms of initiation and build-up of such large CWC mounds are however not yet fully understood. It is therefore essential to study smaller mounds (often termed "mini-mounds") that can be interpreted as earlier growth stages that haven't had the time to coalesce and develop into larger mounds. The FWO Minimound project (2013-2017) aims to investigate CWC mini-mounds within the Bay of Biscay (European Margin) in order to determine the impact of: (1) palaeoceanographic changes related to glacial-interglacial climate change in the last 15 ka, (2) hydrocarbon seepage processes and (3) anthropogenic fishing activities on CWC habitats. The project targets three minimound provinces: the Ferrol Canyon (Cantabrian Margin), the Guilvinec Canyon (Armorican Margin) and the Explorer and Dangeard Canyons (Celtic Margin). These mini-mounds are fossil and occur at relative shallow depths on the interface between the Eastern North Atlantic Central Water (ENACW) and the Mediterranean Outflow Water (MOW). Contrastingly, most living CWC reefs in this region of the Atlantic, dwell in the deeper MOW depth range, relying on the density and dynamics of this water mass for their food supply. In order to investigate the initiation, growth and demise of CWC mini-mounds, 35m of USBL guided sediment cores were retrieved from the Explorer and Dangeard Interfluves. We present data of sedimentological, geochemical and palaeoceanographic analyses throughout the cores, coupled with high-resolution geophysical data. Preliminary results indicate that the mound base is associated with a strong shift in sedimentation regime potentially linked to climate driven palaeoceanographic changes of the MOW-ENACW interface.

  11. Sialidases from gut bacteria: a mini-review.

    PubMed

    Juge, Nathalie; Tailford, Louise; Owen, C David

    2016-02-01

    Sialidases are a large group of enzymes, the majority of which catalyses the cleavage of terminal sialic acids from complex carbohydrates on glycoproteins or glycolipids. In the gastrointestinal (GI) tract, sialic acid residues are mostly found in terminal location of mucins via α2-3/6 glycosidic linkages. Many enteric commensal and pathogenic bacteria can utilize sialic acids as a nutrient source, but not all express the sialidases that are required to release free sialic acid. Sialidases encoded by gut bacteria vary in terms of their substrate specificity and their enzymatic reaction. Most are hydrolytic sialidases, which release free sialic acid from sialylated substrates. However, there are also examples with transglycosylation activities. Recently, a third class of sialidases, intramolecular trans-sialidase (IT-sialidase), has been discovered in gut microbiota, releasing (2,7-anhydro-Neu5Ac) 2,7-anydro-N-acetylneuraminic acid instead of sialic acid. Reaction specificity varies, with hydrolytic sialidases demonstrating broad activity against α2,3-, α2,6- and α2,8-linked substrates, whereas IT-sialidases tend to be specific for α2,3-linked substrates. In this mini-review, we summarize the current knowledge on the structural and biochemical properties of sialidases involved in the interaction between gut bacteria and epithelial surfaces. © 2016 Authors.

  12. A Risk Prediction Model for the Assessment and Triage of Women with Hypertensive Disorders of Pregnancy in Low-Resourced Settings: The miniPIERS (Pre-eclampsia Integrated Estimate of RiSk) Multi-country Prospective Cohort Study

    PubMed Central

    Payne, Beth A.; Hutcheon, Jennifer A.; Ansermino, J. Mark; Hall, David R.; Bhutta, Zulfiqar A.; Bhutta, Shereen Z.; Biryabarema, Christine; Grobman, William A.; Groen, Henk; Li, Jing; Magee, Laura A.; Merialdi, Mario; Nakimuli, Annettee; Qu, Ziguang; Sikandar, Rozina; Sass, Nelson; Sawchuck, Diane; Steyn, D. Wilhelm; Widmer, Mariana; Zhou, Jian; von Dadelszen, Peter

    2014-01-01

    Background Pre-eclampsia/eclampsia are leading causes of maternal mortality and morbidity, particularly in low- and middle- income countries (LMICs). We developed the miniPIERS risk prediction model to provide a simple, evidence-based tool to identify pregnant women in LMICs at increased risk of death or major hypertensive-related complications. Methods and Findings From 1 July 2008 to 31 March 2012, in five LMICs, data were collected prospectively on 2,081 women with any hypertensive disorder of pregnancy admitted to a participating centre. Candidate predictors collected within 24 hours of admission were entered into a step-wise backward elimination logistic regression model to predict a composite adverse maternal outcome within 48 hours of admission. Model internal validation was accomplished by bootstrapping and external validation was completed using data from 1,300 women in the Pre-eclampsia Integrated Estimate of RiSk (fullPIERS) dataset. Predictive performance was assessed for calibration, discrimination, and stratification capacity. The final miniPIERS model included: parity (nulliparous versus multiparous); gestational age on admission; headache/visual disturbances; chest pain/dyspnoea; vaginal bleeding with abdominal pain; systolic blood pressure; and dipstick proteinuria. The miniPIERS model was well-calibrated and had an area under the receiver operating characteristic curve (AUC ROC) of 0.768 (95% CI 0.735–0.801) with an average optimism of 0.037. External validation AUC ROC was 0.713 (95% CI 0.658–0.768). A predicted probability ≥25% to define a positive test classified women with 85.5% accuracy. Limitations of this study include the composite outcome and the broad inclusion criteria of any hypertensive disorder of pregnancy. This broad approach was used to optimize model generalizability. Conclusions The miniPIERS model shows reasonable ability to identify women at increased risk of adverse maternal outcomes associated with the hypertensive disorders of pregnancy. It could be used in LMICs to identify women who would benefit most from interventions such as magnesium sulphate, antihypertensives, or transportation to a higher level of care. Please see later in the article for the Editors' Summary PMID:24465185

  13. CADD Modeling of Multi-Target Drugs Against Alzheimer's Disease.

    PubMed

    Ambure, Pravin; Roy, Kunal

    2017-01-01

    Alzheimer's disease (AD) is a neurodegenerative disorder that is described by multiple factors linked with the progression of the disease. The currently approved drugs in the market are not capable of curing AD; instead, they merely provide symptomatic relief. Development of multi-target directed ligands (MTDLs) is an emerging strategy for improving the quality of the treatment against complex diseases like AD. Polypharmacology is a branch of pharmaceutical sciences that deals with the MTDL development. In this mini-review, we have summarized and discussed different strategies that are reported in the literature to design MTDLs for AD. Further, we have discussed the role of different in silico techniques and online resources in computer-aided drug discovery (CADD), for designing or identifying MTDLs against AD. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. Self-reported history of stroke and long-term living conditions near air pollution sources: results of a national epidemiological study in Lebanon.

    PubMed

    Salameh, Pascale; Farah, Rita; Hallit, Souheil; Zeidan, Rouba Karen; Chahine, Mirna N; Asmar, Roland; Hosseini, Hassan

    2018-02-20

    Stroke is a disease related to high mortality and morbidity, particularly in developing countries. Some studies have linked self-reported indoor and outdoor pollution to stroke and mini-stroke, while some others showed no association. Our objective was to assess this association in Lebanon, a Middle Eastern developing country. A national cross-sectional study was conducted all over Lebanon. In addition to self-reported items of pollution exposure, we assessed potential predictors of stroke and mini-stroke, including sociodemographic characteristics, self-reported health information, and biological measurements. Moreover, we assessed dose-effect relationship of pollution items in relation with stroke. Self-reported indoor pollution exposure was associated with stroke and mini-stroke, with or without taking biological values into account. Moreover, we found a dose-effect relationship of exposure with risk of disease, but this effect did not reach statistical significance after adjustment for sociodemographics and biological characteristics. No association was found for any outdoor pollution item. Although additional studies would be necessary to confirm these findings, sensitizing the population about the effect of pollution on chronic diseases, working on reducing pollution, and improving air quality should be implemented to decrease the burden of the disease on the population and health system.

  15. Development of a Scale-up Tool for Pervaporation Processes

    PubMed Central

    Thiess, Holger; Strube, Jochen

    2018-01-01

    In this study, an engineering tool for the design and optimization of pervaporation processes is developed based on physico-chemical modelling coupled with laboratory/mini-plant experiments. The model incorporates the solution-diffusion-mechanism, polarization effects (concentration and temperature), axial dispersion, pressure drop and the temperature drop in the feed channel due to vaporization of the permeating components. The permeance, being the key model parameter, was determined via dehydration experiments on a mini-plant scale for the binary mixtures ethanol/water and ethyl acetate/water. A second set of experimental data was utilized for the validation of the model for two chemical systems. The industrially relevant ternary mixture, ethanol/ethyl acetate/water, was investigated close to its azeotropic point and compared to a simulation conducted with the determined binary permeance data. Experimental and simulation data proved to agree very well for the investigated process conditions. In order to test the scalability of the developed engineering tool, large-scale data from an industrial pervaporation plant used for the dehydration of ethanol was compared to a process simulation conducted with the validated physico-chemical model. Since the membranes employed in both mini-plant and industrial scale were of the same type, the permeance data could be transferred. The comparison of the measured and simulated data proved the scalability of the derived model. PMID:29342956

  16. Silicone hydrogel mini-scleral contact lenses in early stage after corneal collagen cross-linking for keratoconus: a retrospective case series.

    PubMed

    Severinsky, Boris; Wajnsztajn, Denise; Frucht-Pery, Joseph

    2013-11-01

     The aim was to the evaluate performance of a novel silicone hydrogel mini-scleral contact lens (SHmS) for optical correction of keratoconus in the early stages after the corneal collagen cross-linking procedure (CXL).  We retrospectively analysed the visual acuity improvement and corneal adaptation in the first 10 eyes of nine patients fitted with SHmS lenses one to 3.5 months after corneal collagen cross-linking. The lenses were designed to rest over the patients' sclera and peri-limbal cornea and vault the central cornea with minimal support over it. Visual acuities with manifest refraction and contact lenses, refractive and topographical values (Kmin and Kmax) were evaluated on lens dispensing and after six month of lens wearing. Ocular physiological responses were evaluated using the Institute of Eye Research (IER) grading scales.  SHmS fitting was performed 2.1 ± 0.97 (SD) months after collagen cross-linking. Mean follow up was 10.9 ± 4.41 months (range six to 18 months). Mean decimal visual acuity with SHmS was 0.66 ± 0.22 (approximately 6/9 Snellen fraction, range 0.3 to 0.1) or 0.75 ± 0.14 (approximately 6/8.1, range 0.5 to 1.0), when omitting two amblyopic eyes. Nine (90 per cent) eyes were successfully fitted, that is, able to wear the lenses for 10 hours per day or longer. Mean wearing time was 11.7 hours (range six to 14) per day. No corneal neovascularisation or papillary reaction was found in all fitted eyes.  SHmS contact lenses provide successful visual rehabilitation shortly after corneal collagen cross-linking. This new soft contact lens design with scleral fixation and minimal apical touch was demonstrated to be safe shortly after collagen cross-linking, as the avoidance of contact with the treated zone minimises contact lens influence on corneal recovery. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  17. Drosophila mini-white model system: new insights into positive position effects and the role of transcriptional terminators and gypsy insulator in transgene shielding

    PubMed Central

    Silicheva, Margarita; Golovnin, Anton; Pomerantseva, Ekaterina; Parshikov, Aleksander; Georgiev, Pavel; Maksimenko, Oksana

    2010-01-01

    The white gene, which is responsible for eye pigmentation, is widely used to study position effects in Drosophila. As a result of insertion of P-element vectors containing mini-white without enhancers into random chromosomal sites, flies with different eye color phenotypes appear, which is usually explained by the influence of positive/negative regulatory elements located around the insertion site. We found that, in more than 70% of cases when mini-white expression was subject to positive position effects, deletion of the white promoter had no effect on eye pigmentation; in these cases, the transposon was inserted into the transcribed regions of genes. Therefore, transcription through the mini-white gene could be responsible for high levels of its expression in most of chromosomal sites. Consistently with this conclusion, transcriptional terminators proved to be efficient in protecting mini-white expression from positive position effects. On the other hand, the best characterized Drosophila gypsy insulator was poorly effective in terminating transcription and, as a consequence, only partially protected mini-white expression from these effects. Thus, to ensure maximum protection of a transgene from position effects, a perfect boundary/insulator element should combine three activities: to block enhancers, to provide a barrier between active and repressed chromatin, and to terminate transcription. PMID:19854952

  18. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Abdelaziz, Omar; Shrestha, Som S

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heatmore » exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.« less

  19. The effects of teaching a science topic in the Regents Living Environment course in a mini-lesson instructional environment

    NASA Astrophysics Data System (ADS)

    Barrows, Calder James

    This study investigated the effects on high school students' understanding of studying a science topic in the Regents Living Environment course using a Mini-Lesson educational protocol. Mini-Lesson instruction is one of guided instruction, which consists primarily of three sections. First, a brief, focused section in which the teachers explicitly teach the skills and strategies that students need to know in preparation for the second part, the students engagement or workshop activity session. During this time, students work with one another, working independently, in pairs and in groups applying various skills. Students read, discuss ideas, make interpretations, investigate and talk about the focus of the lesson with peers and teacher. A variety of resources are used, including notes, textbooks, teacher handouts, and the teacher providing guidance, monitoring student work and sometimes calling brief call conferences to link ideas and explain student concerns. The third section of Mini-Lesson brings students together as a whole to integrate and share their findings. In the Mini-Lesson instructional process there is a gradual shift of the learning responsibility from the teacher to the students. In this study two sets of clinical interviews were conducted after students' participation in pre-test, and formal instruction about the cell structure and function using the Mini-Lesson instructional protocol, and post-test. Fourteen students enrolled in a regular New York State Regents living environment course and three teachers were interviewed. Three other students participated in the pilot study. The findings from the study showed that students had considerable difficulty with several areas relating to basic biology about the cell structure and function, and did not have an integrated conceptual understanding of the topic. The study revealed that Mini-Lesson instruction appeared to impact student learning and understanding as to how to communicate and share ideas. As a result there were indications of modest improvements on the post-test, improved attendance and class participation. In light of this study, a shift in instruction is called for to meet the needs of the growing diverse populations of students. A balanced and comprehensive approach to assess student progress should be designed and implemented. This should include diagnostic feedback concerning students' readiness levels and related interventions to maximize individual students' progress towards achieving the goals of the Regents Living Environment course. Finally, the study recommends the establishment of a classroom community where shared goals are met by individuals and teams engaged and working together to capitalize on the talents and strengths of every member of the learning community.

  20. Diversified seabed substrate, sediment remobilisation and fluid migration features offshore NW Greenland - new insights from marine seismic data acquisition in the Northern Nares Strait during the RV Oden cruise 2015

    NASA Astrophysics Data System (ADS)

    Andresen, Katrine Juul; Heirman, Katrien; Kamla, Elina; Nielsen, Tove; Rønø Clausen, Ole; Jakobsson, Martin; Mix, Alan C.; Andersen, Søren T.; Nørmark, Egon; Piotrowski, Jan A.; Knutz, Paul; Larsen, Nicolaj K.; Hogan, Kelly

    2016-04-01

    We present some preliminary observations from acquired seismic data from the Northern Nares Strait, NW Greenland. The studied area covers the Hall Basin in front of the Petermann Glacier and extends southward into the Kennedy Channel. It represents an area intensely affected by glacial related processes as well as deep tectonics. The data were acquired during the RV Oden cruise in late summer 2015, and thus represent valuable input to the understanding of the geological development of this scarcely accessed area of the Arctic. The data were acquired in nearly ice-free conditions and consist of >700 km 2D seismic airgun data, supplemented by high-resolution subbottom profiler data and multibeam data. The different acoustic data acquired simultaneously enable us to correlate deeper geological observations (e.g. faults observed on airgun seismics) with shallow depositional architectures (observed on subbottom profiler) and finally correlate the relatively scattered 2D interpretation with the detailed 3D seafloor morphology obtained by the multibeam. The seismic data reveal several provinces of varying seabed substrate geometry. The provinces include A: confined mini-basins; B: larger sedimentary basins; C: larger structural highs and D: "rough-and-faulted" terrain. The data also reveal a number of seismic anomalies, which indicate fluid flow and sediment remobilisation. The mini-basins are 100-600 m wide, in contrast to the larger basins which typically extend over 6-12 km. The mini-basins are characterized by a flat, smooth and continuous seafloor reflection and have an infill dominated by parallel and sub-horizontal reflections onlapping the edges of the basins. The larger basins, where the internal reflection pattern appears more diverse and less parallel, have much greater relief at the seafloor. Vertical disturbance zones typically emerging above minor structures at the floor of the mini-basins are likely related to vertical fluid migration. The zones occasionally continue to the seafloor but more often terminate within the sediments. Scattered amplitude anomalies in conjunction with sag-like depressions are further potential indications of fluid migration within the mini-basins (palaeo-pockmarks?). Slumps and mounded features within the mini-basins and at the larger structural highs indicate syn-depositional sediment remobilisation. A BSR-like reflection, potentially representing the base of gas hydrates, is occasionally observed in the larger sedimentary basins (ca. 15-20 ms TWT b.s.fl.) and at the culmination of the larger structural highs (ca. 40-50 ms TWT b.s.fl.). Cone-shaped to elongated ridges 15-20 m high and 500 m across appear to be linked with deeper structures and might indicate remobilisation of the shallow subsurface sediments potentially linked to fluid escape. Alternatively, they might be of glacial origin. Our preliminary results indicate that the basins are filled with subglacial and glaciofluvial sediments and that small-scale fluid migration and sediment remobilisation represent important processes in generating the depositional architecture in the Northern Nares Strait region. Further analyses are expected to constrain the interpretation of the observed features in detail, especially regarding the origin of the fluids.

  1. An Asynchronous Many-Task Implementation of In-Situ Statistical Analysis using Legion.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pebay, Philippe Pierre; Bennett, Janine Camille

    2015-11-01

    In this report, we propose a framework for the design and implementation of in-situ analy- ses using an asynchronous many-task (AMT) model, using the Legion programming model together with the MiniAero mini-application as a surrogate for full-scale parallel scientific computing applications. The bulk of this work consists of converting the Learn/Derive/Assess model which we had initially developed for parallel statistical analysis using MPI [PTBM11], from a SPMD to an AMT model. In this goal, we propose an original use of the concept of Legion logical regions as a replacement for the parallel communication schemes used for the only operation ofmore » the statistics engines that require explicit communication. We then evaluate this proposed scheme in a shared memory environment, using the Legion port of MiniAero as a proxy for a full-scale scientific application, as a means to provide input data sets of variable size for the in-situ statistical analyses in an AMT context. We demonstrate in particular that the approach has merit, and warrants further investigation, in collaboration with ongoing efforts to improve the overall parallel performance of the Legion system.« less

  2. Examining the Impact of Drifted Polytomous Anchor Items on Test Characteristic Curve (TCC) Linking and IRT True Score Equating. Research Report. ETS RR-12-09

    ERIC Educational Resources Information Center

    Li, Yanmei

    2012-01-01

    In a common-item (anchor) equating design, the common items should be evaluated for item parameter drift. Drifted items are often removed. For a test that contains mostly dichotomous items and only a small number of polytomous items, removing some drifted polytomous anchor items may result in anchor sets that no longer resemble mini-versions of…

  3. Developing Positive Behavioral Support for Students with Challenging Behaviors. From the Third CCBD Mini-Library Series, What Works for Children and Youth with E/BD: Linking Yesterday and Today with Tomorrow.

    ERIC Educational Resources Information Center

    Sugai, George, Ed.; Lewis, Timothy J., Ed.

    This monograph is a guide to positive behavioral intervention and support (PBIS) and functional behavioral assessment (FBA) in the special education of students with behavior disorders as emphasized in the 1997 amendments to the Individuals with Disabilities Act (IDEA 97). An introduction explains that positive behavioral support represents the…

  4. Availability of Ada and C++ Compilers, Tools, Education and Training

    DTIC Science & Technology

    1991-07-01

    executable mini-specs, to support import of existing code. Automated database population/change propagation. 9. Documentation generation: via FrameMaker . 10...formats. 12. Links to other tools: i. Atherton’s Software Backplane. ii. 4GLS iii. Interleaf and FrameMaker publishing. 13. Output formats: PostScript...by end 󈨟. 11. Output formats: ASCII, PostScript, Interleaf, HPGL, Troff, nroff, FrameMaker , WordPerfect. 12. User interface: Menu and mouse

  5. Formulation and In-vitro Characterization of Sustained Release Matrix Type Ocular Timolol Maleate Mini-Tablet

    PubMed Central

    Mortazavi, Seyed Alireza; Jafariazar, Zahra; Ghadjahani, Yasaman; Mahmoodi, Hoda; Mehtarpour, Farzaneh

    2014-01-01

    The purpose of this study was preparation and evaluation of sustained release matrix type ocular mini-tablets of timolol maleate, as a potential formulation for the treatment of glaucoma. Following the initial studies on timolol maleate powder, it was formulated into ocular mini-tablets. The polymers investigated in this study included cellulose derivatives (HEC, CMC, EC) and Carbopol 971P. Mannitol was used as the solubilizing agent and magnesium stearate as the lubricant. Mini-tablets were prepared by through mixing of the ingredients, followed by direct compression. All the prepared formulations were evaluated in terms of physicochemical tests, including uniformity of weight, thickness, crushing strength, friability and in-vitro drug release. Four groups of formulations were prepared. The presence of different amounts of cellulose derivatives or Carbopol 971P, alone, was studied in group A formulations. In group B formulations, the effect of adding Carbopol 971P alongside different cellulose derivatives was investigated. Group C formulations were made by including mannitol as the solubilizing agent, alongside Carbopol 971P and a cellulose derivative. In group D formulations, mini-tablets were made using Carbopol 971P, alongside two different cellulose derivative. The selected formulation (C1) contained ethyl cellulose, Carbopol 971P, mannitol and magnesium stearate, which showed almost 100% drug release over 5 h. Based on kinetic studies, this formulation was found to best fit the zero-order model of drug release. However, the Higuchi and Hixson -Crowell models also showed a good fit. Hence, overall, formulation C1 was chosen as the best formulation. PMID:24734053

  6. Attenuation of Staphylococcus aureus-Induced Bacteremia by Human Mini-Antibodies Targeting the Complement Inhibitory Protein Efb.

    PubMed

    Georgoutsou-Spyridonos, Maria; Ricklin, Daniel; Pratsinis, Haris; Perivolioti, Eustathia; Pirmettis, Ioannis; Garcia, Brandon L; Geisbrecht, Brian V; Foukas, Periklis G; Lambris, John D; Mastellos, Dimitrios C; Sfyroera, Georgia

    2015-10-15

    Staphylococcus aureus can cause a broad range of potentially fatal inflammatory complications (e.g., sepsis and endocarditis). Its emerging antibiotic resistance and formidable immune evasion arsenal have emphasized the need for more effective antimicrobial approaches. Complement is an innate immune sensor that rapidly responds to bacterial infection eliciting C3-mediated opsonophagocytic and immunomodulatory responses. Extracellular fibrinogen-binding protein (Efb) is a key immune evasion protein of S. aureus that intercepts complement at the level of C3. To date, Efb has not been explored as a target for mAb-based antimicrobial therapeutics. In this study, we have isolated donor-derived anti-Efb IgGs that attenuate S. aureus survival through enhanced neutrophil killing. A phage library screen yielded mini-Abs that selectively inhibit the interaction of Efb with C3 partly by disrupting contacts essential for complex formation. Surface plasmon resonance-based kinetic analysis enabled the selection of mini-Abs with favorable Efb-binding profiles as therapeutic leads. Mini-Ab-mediated blockade of Efb attenuated S. aureus survival in a whole blood model of bacteremia. This neutralizing effect was associated with enhanced neutrophil-mediated killing of S. aureus, increased C5a release, and modulation of IL-6 secretion. Finally, these mini-Abs afforded protection from S. aureus-induced bacteremia in a murine renal abscess model, attenuating bacterial inflammation in kidneys. Overall, these findings are anticipated to pave the way toward novel Ab-based therapeutics for S. aureus-related diseases. Copyright © 2015 by The American Association of Immunologists, Inc.

  7. Biomimicking of a Swim Bladder and Its Application as a Mini-Generator.

    PubMed

    Song, Mengmeng; Cheng, Mengjiao; Xiao, Meng; Zhang, Lina; Ju, Guannan; Shi, Feng

    2017-02-01

    A model fish with a man-made swim bladder achieves fast vertical motions based on density adjustments in a pressure-responsive way. When exposed to a magnetic field, a mini-generator is achieved by harvesting energy from the environment, working with pressure differences in the blood-pressure range and at the frequency of a beating heart. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Using the Longman Mini-concordancer on Tagged and Parsed Corpora, with Special Reference to Their Use as an Aid to Grammar Learning.

    ERIC Educational Resources Information Center

    Qiao, Hong Liang; Sussex, Roland

    1996-01-01

    Presents methods for using the Longman Mini-Concordancer on tagged and parsed corpora rather than plain text corpora. The article discusses several aspects with models to be applied in the classroom as an aid to grammar learning. This paper suggests exercises suitable for teaching English to both native and nonnative speakers. (13 references)…

  9. Neutrino Nucleon Elastic Scattering in MiniBooNE

    NASA Astrophysics Data System (ADS)

    Cox, D. Christopher

    2007-12-01

    Neutrino nucleon elastic scattering νN→νN is a fundamental process of the weak interaction, and can be used to study the structure of the nucleon. This is the third largest scattering process in MiniBooNE comprising ˜15% of all neutrino interactions. Analysis of this sample has yielded a neutral current elastic differential cross section as a function of Q2 that agrees within errors to model predictions.

  10. Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agostinetti, P., E-mail: piero.agostinetti@igi.cnr.it; Serianni, G.; Veltri, P.

    The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method tomore » estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.« less

  11. Mini-Spec: A Compact, Fiber-Coupled, VPH Grating Spectrograph for Small Observatories

    NASA Astrophysics Data System (ADS)

    Nations, H. L.; Haynes, P.; Brewer, P.

    2003-05-01

    We report on the development and testing of what we believe to be the first VPH grating based spectrograph developed primarily for use at telescopes of modest aperture. To date, the most common instrument suite for such observatories is typically that of a CCD camera with attached filter wheel. While there is no doubt that a wide range of interesting and good science has been done with such instrumentation, the addition of a robust and easy to operate spectrograph would greatly increase the utility of such installations. While some commercial spectrographs exist for use on small telescopes, the authors have found them to be, with few exceptions, either inefficient, difficult for inexperienced students or amateurs to use, or not remotely operable. Correcting these deficiencies is thus the primary motivation for Mini-Spec. The design of Mini-Spec has been influenced by previous work the authors have done on a full-sized fiber-coupled spectrograph (Nations and Pierce, 2002). Mini-Spec uses some of those original design features, only reduced drastically in size. This size reduction (the spectrograph fits within a 7 inch cube), along with a much more careful choice of some critical components, has resulted in a dramatic reduction in cost. The spectrograph uses a highly efficient 1200 l/mm, 40 mm diameter vph grating on loan from Richard Rallison. Focus, central wavelength selection, and comparison lamps are all controlled via an RS-232 link and a custom Visual Basic GUI. Sample spectra of stellar and non-stellar targets will be presented along with a discussion of research projects admirably suited for this instrument. Funding for equipment has been provided by a NASA EPSCoR grant to PI Ron Canterna. HLN has been partially funded by a Wyoming Space Grant Faculty Fellowship.

  12. Mineralogy at Meridiani Planum from the Mini-TES experiment on the opportunity rover

    USGS Publications Warehouse

    Christensen, P.R.; Wyatt, M.B.; Glotch, T.D.; Rogers, A.D.; Anwar, S.; Arvidson, R. E.; Bandfield, J.L.; Blaney, D.L.; Budney, C.; Calvin, W.M.; Fallacaro, A.; Fergason, R.L.; Gorelick, N.; Graff, T.G.; Hamilton, V.E.; Hayes, A.G.; Johnson, J. R.; Knudson, A.T.; McSween, H.Y.; Mehall, G.L.; Mehall, L.K.; Moersch, J.E.; Morris, R.V.; Smith, M.D.; Squyres, S. W.; Ruff, S.W.; Wolff, M.J.

    2004-01-01

    The Miniature Thermal Emission Spectrometer (Mini-TES) on Opportunity investigated the mineral abundances and compositions of outcrops, rocks, and soils at Meridiani Planum. Coarse crystalline hematite and olivine-rich basaltic sands were observed as predicted from orbital TES spectroscopy. Outcrops of aqueous origin are composed of 15 to 35% by volume magnesium and calcium sulfates [a high-silica component modeled as a combination of glass, feldspar, and sheet silicates (???20 to 30%)], and hematite; only minor jarosite is identified in Mini-TES spectra. Mini-TES spectra show only a hematite signature in the millimeter-sized spherules. Basaltic materials have more plagioclase than pyroxene, contain olivine, and are similar in inferred mineral composition to basalt mapped from orbit. Bounce rock is dominated by clinopyroxene and is close in inferred mineral composition to the basaltic martian meteorites. Bright wind streak material matches global dust. Waterlain rocks covered by unaltered basaltic sands suggest a change from an aqueous environment to one dominated by physical weathering.

  13. A study of the flow boiling heat transfer in an annular heat exchanger with a mini gap

    NASA Astrophysics Data System (ADS)

    Musiał, Tomasz; Piasecka, Magdalena; Hożejowska, Sylwia

    In this paper the research on flow boiling heat transfer in an annular mini gap was discussed. A one- dimensional mathematical approach was proposed to describe stationary heat transfer in the gap. The mini gap 1 mm wide was created between a metal pipe with enhanced exterior surface and an external tempered glass pipe positioned along the same axis. The experimental test stand consists of several systems: the test loop in which distilled water circulates, the data and image acquisition system and the supply and control system. Known temperature distributions of the metal pipe with enhanced surface and of the working fluid helped to determine, from the Robin boundary condition, the local heat transfer coefficients at the fluid - heated surface contact. In the proposed mathematical model it is assumed that the cylindrical wall is a planar multilayer wall. The numerical results are presented on a chart as function of the heat transfer coefficient along the length of the mini gap.

  14. Estuarine Facies Model Revisited: Conceptual Model of Estuarine Sediment Dynamics During Non-Equilibrium Conditions

    NASA Astrophysics Data System (ADS)

    Elliott, E. A.; Rodriguez, A. B.; McKee, B. A.

    2017-12-01

    Traditional models of estuarine systems show deposition occurs primarily within the central basin. There, accommodation space is high within the deep central valley, which is below regional wave base and where current energy is presumed to reach a relative minimum, promoting direct deposition of cohesive sediment and minimizing erosion. However, these models often reflect long-term (decadal-millennial) timescales, where accumulation rates are in relative equilibrium with the rate of relative sea-level rise, and lack the resolution to capture shorter term changes in sediment deposition and erosion within the central estuary. This work presents a conceptual model for estuarine sedimentation during non-equilibrium conditions, where high-energy inputs to the system reach a relative maximum in the central basin, resulting in temporary deposition and/or remobilization over sub-annual to annual timescales. As an example, we present a case study of Core Sound, NC, a lagoonal estuarine system where the regional base-level has been reached, and sediment deposition, resuspension and bypassing is largely a result of non-equilibrium, high-energy events. Utilizing a 465 cm-long sediment core from a mini-basin located between Core Sound and the continental shelf, a 40-year sub-annual chronology was developed for the system, with sediment accumulation rates (SAR) interpolated to a monthly basis over the 40-year record. This study links erosional processes in the estuary directly with sediment flux to the continental shelf, taking advantage of the highly efficient sediment trapping capability of the mini-basin. The SAR record indicates high variation in the estuarine sediment supply, with peaks in the SAR record at a recurrence interval of 1 year (+/- 0.25). This record has been compared to historical storm influence for the area. Through this multi-decadal record, sediment flushing events occur at a much more frequent interval than previously thought (i.e. annual rather than decadal timescales). This non-equilibrium estuarine model highlights moderate-energy events that impact the coast at least every year, in addition to high energy less frequent decadal to millennial events for modulating sediment and particulate matter erosion and transport through the estuary and delivery to the continental shelf.

  15. The Crystal Structure of a Maxi/Mini-Ferritin Chimera Reveals Guiding Principles for the Assembly of Protein Cages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornell, Thomas A.; Srivastava, Yogesh; Jauch, Ralf

    Cage proteins assemble into nanoscale structures with large central cavities. They play roles, including those as virus capsids and chaperones, and have been applied to drug delivery and nanomaterials. Furthermore, protein cages have been used as model systems to understand and design protein quaternary structure. Ferritins are ubiquitous protein cages that manage iron homeostasis and oxidative damage. Two ferritin subfamilies have strongly similar tertiary structure yet distinct quaternary structure: maxi-ferritins normally assemble into 24-meric, octahedral cages with C-terminal E-helices centered around 4-fold symmetry axes, and mini-ferritins are 12-meric, tetrahedral cages with 3-fold axes defined by C-termini lacking E-domains. To understandmore » the role E-domains play in ferritin quaternary structure, we previously designed a chimera of a maxi-ferritin E-domain fused to the C-terminus of a mini-ferritin. The chimera is a 12-mer cage midway in size between those of the maxi- and mini-ferritin. The research described herein sets out to understand (a) whether the increase in size over a typical mini-ferritin is due to a frozen state where the E-domain is flipped out of the cage and (b) whether the symmetrical preference of the E-domain in the maxi-ferritin (4-fold axis) overrules the C-terminal preference in the mini-ferritin (3-fold axis). With a 1.99 Å resolution crystal structure, we determined that the chimera assembles into a tetrahedral cage that can be nearly superimposed with the parent mini-ferritin, and that the E-domains are flipped external to the cage at the 3-fold symmetry axes.« less

  16. Development of the Mini-Assisting Hand Assessment: evidence for content and internal scale validity.

    PubMed

    Greaves, Susan; Imms, Christine; Dodd, Karen; Krumlinde-Sundholm, Lena

    2013-11-01

    To describe the development of the Mini-Assisting Hand Assessment (Mini-AHA) for children with signs of unilateral cerebral palsy (CP) aged 8 to 18 months, and evaluate aspects of content and internal scale validity. The ability of the video-recorded Mini-AHA play session to provoke bimanual performance in children with unilateral CP and typical development was evaluated. Original AHA test items were examined for their suitability for younger children and possible new items were generated. Data from 108 assessments of children with unilateral CP (86 children, 53 males, 33 females; mean age 13 mo, SD 3 mo, range 8-18 mo) were entered into a Rasch measurement model analysis to evaluate internal scale validity. A Spearman's correlation analysis explored the relationship between age and ability measures for children with unilateral CP. The frequency of maximum scores in 40 children with typical development (22 males, 18 females; mean age 12 mo, SD 3 mo) was examined. The Mini-AHA play session provoked bimanual responses in typically developing children 99% of the time. Person and item fit criteria established 20 items for the scale. The resultant unidimensional scale also demonstrated excellent discriminative features through high separation reliability. The item calibration values covered the range of person ability measures well. Age was not related to the ability measures for children with unilateral CP (rs =0.178). All children with typical development achieved maximum scores. Accumulated evidence shows that the Mini-AHA validly measures use of the affected hand during bimanual performance for children with unilateral CP aged 8 to 18 months. The Mini-AHA has the potential to be a useful assessment to evaluate functional hand use and the effects of intervention in an age group when potential for change is high. © 2013 Mac Keith Press.

  17. Conformational Sampling in Template-Free Protein Loop Structure Modeling: An Overview

    PubMed Central

    Li, Yaohang

    2013-01-01

    Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a “mini protein folding problem” under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized. PMID:24688696

  18. Conformational sampling in template-free protein loop structure modeling: an overview.

    PubMed

    Li, Yaohang

    2013-01-01

    Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a "mini protein folding problem" under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.

  19. Fluoroscopic radiation exposure: are we protecting ourselves adequately?

    PubMed

    Hoffler, C Edward; Ilyas, Asif M

    2015-05-06

    While traditional intraoperative fluoroscopy protection relies on thyroid shields and aprons, recent data suggest that the surgeon's eyes and hands receive more exposure than previously appreciated. Using a distal radial fracture surgery model, we examined (1) radiation exposure to the eyes, thyroid, chest, groin, and hands of a surgeon mannequin; (2) the degree to which shielding equipment can decrease exposure; and (3) how exposure varies with fluoroscopy unit size. An anthropomorphic model was fit with radiation-attenuating glasses, a thyroid shield, an apron, and gloves. "Exposed" thermoluminescent dosimeters overlaid the protective equipment at the eyes, thyroid, chest, groin, and index finger while "shielded" dosimeters were placed beneath the protective equipment. Fluoroscopy position and settings were standardized. The mini-c-arm milliampere-seconds were fixed based on the selection of the kilovolt peak (kVp). Three mini and three standard c-arms scanned a model of the patient's wrist continuously for fifteen minutes each. Ten dosimeter exposures were recorded for each c-arm. Hand exposure averaged 31 μSv/min (range, 22 to 48 μSv/min), which was 13.0 times higher than the other recorded exposures. Eye exposure averaged 4 μSv/min, 2.2 times higher than the mean thyroid, chest, and groin exposure. Gloves reduced hand exposure by 69.4%. Glasses decreased eye exposure by 65.6%. There was no significant difference in exposure between mini and standard fluoroscopy. Surgeons' hands receive the most radiation exposure during distal radial plate fixation under fluoroscopy. There was a small but insignificant difference in mean exposure between standard fluoroscopy and mini-fluoroscopy, but some standard units resulted in lower exposure than some mini-units. On the basis of these findings, we recommend routine protective equipment to mitigate exposure to surgeons' hands and eyes, in addition to the thyroid, chest, and groin, during fluoroscopy procedures. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  20. Electrification pathways for Kenya-linking spatial electrification analysis and medium to long term energy planning

    NASA Astrophysics Data System (ADS)

    Moksnes, Nandi; Korkovelos, Alexandros; Mentis, Dimitrios; Howells, Mark

    2017-09-01

    In September 2015 UN announced 17 Sustainable Development goals (SDG) from which goal number 7 envisions universal access to modern energy services for all by 2030. In Kenya only about 46% of the population currently has access to electricity. This paper analyses hypothetical scenarios, and selected implications, investigating pathways that would allow the country to reach its electrification targets by 2030. Two modelling tools were used for the purposes of this study, namely OnSSET and OSeMOSYS. The tools were soft-linked in order to capture both the spatial and temporal dynamics of their nature. Two electricity demand scenarios were developed representing low and high end user consumption goals respectively. Indicatively, results show that geothermal, coal, hydro and natural gas would consist the optimal energy mix for the centralized national grid. However, in the case of the low demand scenario a high penetration of stand-alone systems is evident in the country, reaching out to approximately 47% of the electrified population. Increasing end user consumption leads to a shift in the optimal technology mix, with higher penetration of mini-grid technologies and grid extension.

  1. Cost Estimation Techniques for C3I System Software.

    DTIC Science & Technology

    1984-07-01

    opment manmonth have been determined for maxi, midi , and mini .1 type computers. Small to median size timeshared developments used 0.2 to 1.5 hours...development schedule 1.23 1.00 1.10 2.1.3 Detailed Model The final codification of the COCOMO regressions was the development of separate effort...regardless of the software structure level being estimated: D8VC -- the expected development computer (maxi. midi . mini, micro) MODE -- the expected

  2. Historical Chronology of the Council for Children with Behavioral Disorders 1964-1999. From the Third CBD Mini-Library Series, What Works for Children and Youth with E/BD: Linking Yesterday and Today with Tomorrow.

    ERIC Educational Resources Information Center

    Bullock, Lyndal M.; Menendez, Anthony L.

    This monograph presents a history of the Council for Children with Behavioral Disorders (CCBD), a division of the Council for Exceptional Children. Since its founding in 1964, the CCBD has been concerned with children and youth with emotional and behavioral disorders. Following an introductory chapter, Chapter 1 highlights CCBD, including its…

  3. Earth's Earliest Ecosystems in the Classroom: The Use of Microbial Mats to Teach General Principles in Microbial Ecology, and Scientific Inquiry

    NASA Technical Reports Server (NTRS)

    Beboutl, Brad M.; Bucaria, Robin

    2004-01-01

    Microbial mats are living examples of the most ancient biological communities on earth, and may also be useful models for the search for life elsewhere. They are centrally important to Astrobiology. In this lecture, we will present an introduction to microbial mats, as well as an introduction to our web-based educational module on the subject of microbial ecology, featuring living mats maintained in a mini "Web Lab" complete with remotely-operable instrumentation. We have partnered with a number of outreach specialists in order to produce an informative and educational web-based presentation, aspects of which will be exported to museum exhibits reaching a wide audience. On our web site, we will conduct regularly scheduled experimental manipulations, linking the experiments to our research activities, and demonstrating fundamental principles of scientific research.

  4. Mini-P-gp and P-gp Co-Expression in Brown Trout Erythrocytes: A Prospective Blood Biomarker of Aquatic Pollution

    PubMed Central

    Valton, Emeline; Amblard, Christian; Desmolles, François; Combourieu, Bruno; Penault-Llorca, Frédérique; Bamdad, Mahchid

    2015-01-01

    In aquatic organisms, such as fish, blood is continually exposed to aquatic contaminants. Multidrug Resistance (MDR) proteins are ubiquitous detoxification membrane pumps, which recognize various xenobiotics. Moreover, their expression is induced by a large class of drugs and pollutants. We have highlighted the co-expression of a mini P-gp of 75 kDa and a P-gp of 140 kDa in the primary culture of brown trout erythrocytes and in the erythrocytes of wild brown trout collected from three rivers in the Auvergne region of France. In vitro experiments showed that benzo[a]pyrene, a highly toxic pollutant model, induced the co-expression of mini-P-gp and P-gp in trout erythrocytes in a dose-dependent manner and relay type response. Similarly, in the erythrocytes of wild brown trout collected from rivers contaminated by a mixture of PAH and other multi-residues of pesticides, mini-P-gp and P-gp were able to modulate their expression, according to the nature of the pollutants. The differential and complementary responses of mini-P-gp and P-gp in trout erythrocytes suggest the existence in blood cells of a real protective network against xenobiotics/drugs. This property could be exploited to develop a blood biomarker of river pollution. PMID:26854141

  5. Validity of a Smartphone-Based Fall Detection Application on Different Phones Worn on a Belt or in a Trouser Pocket.

    PubMed

    Vermeulen, Joan; Willard, Sarah; Aguiar, Bruno; De Witte, Luc P

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of a smartphone-based fall detection application when different smartphone models are worn on a belt or in a trouser pocket. Eight healthy adults aged between 18 and 24 years old simulated 10 different types of true falls, 5 different types of falls with recovery, and 11 daily activities, five consecutive times. Participants wore one smartphone in a pocket that was attached to their belt and another one in their trouser pocket. All smartphones were equipped with a built-in accelerometer and the fall detection application. Four participants tested the application on a Samsung S3 and four tested the application on a Samsung S3 mini. Sensitivity scores were .75 (Samsung S3 belt), .88 (Samsung S3 mini trouser pocket), and .90 (Samsung S3 mini belt/Samsung S3 trouser pocket). Specificity scores were .87 (Samsung S3 trouser pocket), .91 (Samsung S3 mini trouser pocket), .97 (Samsung S3 belt), and .99 (Samsung S3 mini belt). These results suggest that an application on a smartphone can generate valid fall alarms when worn on a belt or in a trouser pocket. However, sensitivity should be improved before implementation of the application in practice.

  6. PVP VA64 as a novel release-modifier for sustained-release mini-matrices prepared via hot melt extrusion.

    PubMed

    Li, Yongcheng; Lu, Ming; Wu, Chuanbin

    2017-11-10

    The purpose of this study was to explore poly(vinylpyrrolidone-co-vinyl acetate) (PVP VA64) as a novel release-modifier to tailor the drug release from ethylcellulose (EC)-based mini-matrices prepared via hot melt extrusion (HME). Quetiapine fumarate (QF) was selected as model drug. QF/EC/PVP VA64 mini-matrices were extruded with 30% drug loading. The physical state of QF in extruded mini-matrices was characterized using differential scanning calorimetry, X-ray powder diffraction, and confocal Raman microscopy. The release-controlled ability of PVP VA64 was investigated and compared with that of xanthan gum, crospovidone, and low-substituted hydroxypropylcellulose. The influences of PVP VA64 content and processing temperature on QF release behavior and mechanism were also studied. The results indicated QF dispersed as the crystalline state in all mini-matrices. The release of QF from EC was very slow as only 4% QF was released in 24 h. PVP VA64 exhibited the best ability to enhance the drug release as compared with other three release-modifiers. The drug release increased to 50-100% in 24 h with the addition of 20-40% PVP VA64. Increasing processing temperature slightly slowed down the drug release by decreasing free volume and pore size. The release kinetics showed good fit with the Ritger-Peppas model. The values of release exponent (n) increased as PVP VA64 is added (0.14 for pure EC, 0.41 for 20% PVP VA64, and 0.61 for 40% PVP VA64), revealing that the addition of PVP VA64 enhanced the erosion mechanism. This work presented a new polymer blend system of EC with PVP VA64 for sustained-release prepared via HME.

  7. The Aachen miniaturized heart-lung machine--first results in a small animal model.

    PubMed

    Schnoering, Heike; Arens, Jutta; Sachweh, Joerg S; Veerman, Melanie; Tolba, Rene; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Vazquez-Jimenez, Jaime F

    2009-11-01

    Congenital heart surgery most often incorporates extracorporeal circulation. Due to foreign surface contact and the administration of foreign blood in many children, inflammatory response and hemolysis are important matters of debate. This is particularly an issue in premature and low birth-weight newborns. Taking these considerations into account, the Aachen miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102 mL (including tubing) was developed and tested in a small animal model. Fourteen female Chinchilla Bastard rabbits were operated on using two different kinds of circuits. In eight animals, a conventional HLM with Dideco Kids oxygenator and Stöckert roller pump (Sorin group, Milan, Italy) was used, and the Aachen MiniHLM was employed in six animals. Outcome parameters were hemolysis and blood gas analysis including lactate. The rabbits were anesthetized, and a standard median sternotomy was performed. The ascending aorta and the right atrium were cannulated. After initiating cardiopulmonary bypass, the aorta was cross-clamped, and cardiac arrest was induced by blood cardioplegia. Blood samples for hemolysis and blood gas analysis were drawn before, during, and after cardiopulmonary bypass. After 1 h aortic clamp time, all animals were weaned from cardiopulmonary bypass. Blood gas analysis revealed adequate oxygenation and perfusion during cardiopulmonary bypass, irrespective of the employed perfusion system. The use of the Aachen MiniHLM resulted in a statistically significant reduced decrease in fibrinogen during cardiopulmonary bypass. A trend revealing a reduced increase in free hemoglobin during bypass in the MiniHLM group could also be observed. This newly developed Aachen MiniHLM with low priming volume, reduced hemolysis, and excellent gas transfer (O(2) and CO(2)) may reduce circuit-induced complications during heart surgery in neonates.

  8. Dynamics of myosin II organization into cortical contractile networks and fibers

    NASA Astrophysics Data System (ADS)

    Nie, Wei; Wei, Ming-Tzo; Ou-Yang, Daniel; Jedlicka, Sabrina; Vavylonis, Dimitrios

    2014-03-01

    The morphology of adhered cells critically depends on the formation of a contractile meshwork of parallel and cross-linked stress fibers along the contacting surface. The motor activity and mini-filament assembly of non-muscle myosin II is an important component of cell-level cytoskeletal remodeling during mechanosensing. To monitor the dynamics of myosin II, we used confocal microscopy to image cultured HeLa cells that stably express myosin regulatory light chain tagged with GFP (MRLC-GFP). MRLC-GFP was monitored in time-lapse movies at steady state and during the response of cells to varying concentrations of blebbistatin which disrupts actomyosin stress fibers. Using image correlation spectroscopy analysis, we quantified the kinetics of disassembly and reassembly of actomyosin networks and compared them to studies by other groups. This analysis suggested that the following processes contribute to the assembly of cortical actomyosin into fibers: random myosin mini-filament assembly and disassembly along the cortex; myosin mini-filament aligning and contraction; stabilization of cortical myosin upon increasing contractile tension. We developed simple numerical simulations that include those processes. The results of simulations of cells at steady state and in response to blebbistatin capture some of the main features observed in the experiments. This study provides a framework to help interpret how different cortical myosin remodeling kinetics may contribute to different cell shape and rigidity depending on substrate stiffness.

  9. Modeling two-phase flow in PEM fuel cell channels

    NASA Astrophysics Data System (ADS)

    Wang, Yun; Basu, Suman; Wang, Chao-Yang

    2008-05-01

    This paper is concerned with the simultaneous flow of liquid water and gaseous reactants in mini-channels of a proton exchange membrane (PEM) fuel cell. Envisaging the mini-channels as structured and ordered porous media, we develop a continuum model of two-phase channel flow based on two-phase Darcy's law and the M2 formalism, which allow estimate of the parameters key to fuel cell operation such as overall pressure drop and liquid saturation profiles along the axial flow direction. Analytical solutions of liquid water saturation and species concentrations along the channel are derived to explore the dependences of these physical variables vital to cell performance on operating parameters such as flow stoichiometric ratio and relative humility. The two-phase channel model is further implemented for three-dimensional numerical simulations of two-phase, multi-component transport in a single fuel-cell channel. Three issues critical to optimizing channel design and mitigating channel flooding in PEM fuel cells are fully discussed: liquid water buildup towards the fuel cell outlet, saturation spike in the vicinity of flow cross-sectional heterogeneity, and two-phase pressure drop. Both the two-phase model and analytical solutions presented in this paper may be applicable to more general two-phase flow phenomena through mini- and micro-channels.

  10. Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability

    PubMed Central

    Baek, Sun-Hye; Cha, Hyun-Suk; Cha, Jung-Yul; Moon, Yoon-Shik

    2012-01-01

    Objective The aims of this study were to investigate mandibular deformation under clenching and to estimate its effect on the stability of orthodontic mini-implants (OMI). Methods Three finite element models were constructed using computed tomography (CT) images of 3 adults with different mandibular plane angles (A, low; B, average; and C, high). An OMI was placed between #45 and #46 in each model. Mandibular deformation under premolar and molar clenching was simulated. Comparisons were made between peri-orthodontic mini-implant compressive strain (POMI-CSTN) under clenching and orthodontic traction forces (150 g and 200 g). Results Three models with different mandibular plane angles demonstrated different functional deformation characteristics. The compressive strains around the OMI were distributed mesiodistally rather than occlusogingivally. In model A, the maximum POMI-CSTN under clenching was observed at the mesial aspect of #46 (1,401.75 microstrain [µE]), and similar maximum POMI-CSTN was observed under a traction force of 150 g (1,415 µE). Conclusions The maximum POMI-CSTN developed by clenching failed to exceed the normally allowed compressive cortical bone strains; however, additional orthodontic traction force to the OMI may increase POMI-CSTN to compromise OMI stability. PMID:23112947

  11. Antisense phosphorothioate oligonucleotides: selective killing of the intracellular parasite Leishmania amazonensis.

    PubMed

    Ramazeilles, C; Mishra, R K; Moreau, S; Pascolo, E; Toulmé, J J

    1994-08-16

    We targeted the mini-exon sequence, present at the 5' end of every mRNA of the protozoan parasite Leishmania amazonensis, by phosphorothioate oligonucleotides. A complementary 16-mer (16PS) was able to kill amastigotes--the intracellular stage of the parasite--in murine macrophages in culture. After 24 hr of incubation with 10 microM 16PS, about 30% infected macrophages were cured. The oligomer 16PS acted through antisense hybridization in a sequence-dependent way; no effect on parasites was observed with noncomplementary phosphorothioate oligonucleotides. The antisense oligonucleotide 16PS was a selective killer of the protozoans without any detrimental effect to the host macrophage. Using 16PS linked to a palmitate chain, which enabled it to complex with low density lipoproteins, improved the leishmanicidal efficiency on intracellular amastigotes, probably due to increased endocytosis. Phosphorothioate oligonucleotides complementary to the intron part of the mini-exon pre-RNA were also effective, suggesting that antisense oligomers could prevent trans-splicing in these parasites.

  12. [Sensory integration: hierarchy and synchronization].

    PubMed

    Kriukov, V I

    2005-01-01

    This is the first in the series of mini-reviews devoted to the basic problems and most important effects of attention in terms of neuronal modeling. We believe that the absence of the unified view on wealth of new date on attention is the main obstacle for further understanding of higher nervous activity. The present work deals with the main ground problem of reconciling two competing architectures designed to integrate the sensory information in the brain. The other mini-reviews will be concerned with the remaining five or six problems of attention, all of them to be ultimately resolved uniformly in the framework of small modification of dominant model of attention and memory.

  13. Analysis of MINIE2013 Explosion Air-Blast Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schnurr, Julie M.; Rodgers, Arthur J.; Kim, Keehoon

    We report analysis of air-blast overpressure measurements from the MINIE2013 explosive experiments. The MINIE2013 experiment involved a series of nearly 70 near-surface (height-ofburst, HOB, ranging from -1 to +4 m) low-yield (W=2-20 kg TNT equivalent) chemical highexplosives tests that were recorded at local distances (230 m – 28.5 km). Many of the W and HOB combinations were repeated, allowing for quantification of the variability in air-blast features and corresponding yield estimates. We measured canonical signal features (peak overpressure, impulse per unit area, and positive pulse duration) from the air-blast data and compared these to existing air-blast models. Peak overpressure measurementsmore » showed good agreement with the models at close ranges but tended to attenuate more rapidly at longer range (~ 1 km), which is likely caused by upward refraction of acoustic waves due to a negative vertical gradient of sound speed. We estimated yields of the MINIE2013 explosions using the Integrated Yield Determination Tool (IYDT). Errors of the estimated yields were on average within 30% of the reported yields, and there were no significant differences in the accuracy of the IYDT predictions grouped by yield. IYDT estimates tend to be lower than ground truth yields, possibly because of reduced overpressure amplitudes by upward refraction. Finally, we report preliminary results on a development of a new parameterized air-blast waveform.« less

  14. Computational hydrodynamic comparison of a mini vessel and a USP 2 dissolution testing system to predict the dynamic operating conditions for similarity of dissolution performance.

    PubMed

    Wang, Bing; Bredael, Gerard; Armenante, Piero M

    2018-03-25

    The hydrodynamic characteristics of a mini vessel and a USP 2 dissolution testing system were obtained and compared to predict the tablet-liquid mass transfer coefficient from velocity distributions near the tablet and establish the dynamic operating conditions under which dissolution in mini vessels could be conducted to generate concentration profiles similar to those in the USP 2. Velocity profiles were obtained experimentally using Particle Image Velocimetry (PIV). Computational Fluid Dynamics (CFD) was used to predict the velocity distribution and strain rate around a model tablet. A CFD-based mass transfer model was also developed. When plotted against strain rate, the predicted tablet-liquid mass transfer coefficient was found to be independent of the system where it was obtained, implying that a tablet would dissolve at the same rate in both systems provided that the concentration gradient between the tablet surface and the bulk is the same, the tablet surface area per unit liquid volume is identical, and the two systems are operated at the appropriate agitation speeds specified in this work. The results of this work will help dissolution scientists operate mini vessels so as to predict the dissolution profiles in the USP 2, especially during the early stages of drug development. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Process spectroscopy in microemulsions—Raman spectroscopy for online monitoring of a homogeneous hydroformylation process

    NASA Astrophysics Data System (ADS)

    Paul, Andrea; Meyer, Klas; Ruiken, Jan-Paul; Illner, Markus; Müller, David-Nicolas; Esche, Erik; Wozny, Günther; Westad, Frank; Maiwald, Michael

    2017-03-01

    A major industrial reaction based on homogeneous catalysis is hydroformylation for the production of aldehydes from alkenes and syngas. Hydroformylation in microemulsions, which is currently under investigation at Technische Universität Berlin on a mini-plant scale, was identified as a cost efficient approach which also enhances product selectivity. Herein, we present the application of online Raman spectroscopy on the reaction of 1-dodecene to 1-tridecanal within a microemulsion. To achieve a good representation of the operation range in the mini-plant with regard to concentrations of the reactants a design of experiments was used. Based on initial Raman spectra partial least squares regression (PLSR) models were calibrated for the prediction of 1-dodecene and 1-tridecanal. Limits of predictions arise from nonlinear correlations between Raman intensity and mass fractions of compounds in the microemulsion system. Furthermore, the prediction power of PLSR models becomes limited due to unexpected by-product formation. Application of the lab-scale derived calibration spectra and PLSR models on online spectra from a mini-plant operation yielded promising estimations of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions suggesting Raman spectroscopy as a suitable technique for process analytics in microemulsions.

  16. Optimal area of lateral mass mini-screws implanted in plated cervical laminoplasty: a radiography anatomy study.

    PubMed

    Chen, Hua; Li, Huibo; Deng, Yuxiao; Rong, Xin; Gong, Quan; Li, Tao; Song, Yueming; Liu, Hao

    2017-04-01

    Lateral mass mini-screws used in plated cervical laminoplasty might penetrate into facet joints. The objective is to observe this complication incidence and to identify the optimal areas for 5- and 7-mm-long mini-screws to implant on lateral mass. 47 patients who underwent plated cervical laminoplasty were included. The optimal area for mini-screws implanting was set according to pre-operative 3D CT reconstruction data. Then, each posterior-lateral mass surface was divided into three regions: 7-mm region, 5-mm region, and dangerous area. The mini-screw implanted region was recorded. Post-operative CT images were used to identify whether the mini-screws penetrated into facet joints. 235 mini-plates and 470 lateral mass mini-screws were used in the study. 117 (24.9%) mini-screws penetrated 88 (37.4%) facet joints. The 5-mm-long mini-screw optimal area occupied the upper 72, 65, 65, 64, and 65 % area of the posterior-lateral mass surface for C3-7, while the 7-mm-long mini-screw optimal area encompassed the upper 54, 39, 40, 33, and 32 %. Only 7-mm-long mini-screws were used to fix the plate to the lateral mass. 4 of 240 mini-screws in 7-mm region, 67 of the 179 mini-screws in 5-mm region, and 46 of the 51 mini-screws in dangerous region penetrated into the facet joint. The differences in the rate of facet joint penetration related to region were statistically significant (P < 0.001). The facet joint destruction by mini-screws was not a rare complication in plated cervical laminoplasty. The optimal areas we proposed may help guide the mini-screw implantation positions.

  17. Sequential peritoneal equilibration test: a new method for assessment and modelling of peritoneal transport.

    PubMed

    Galach, Magda; Antosiewicz, Stefan; Baczynski, Daniel; Wankowicz, Zofia; Waniewski, Jacek

    2013-02-01

    In spite of many peritoneal tests proposed, there is still a need for a simple and reliable new approach for deriving detailed information about peritoneal membrane characteristics, especially those related to fluid transport. The sequential peritoneal equilibration test (sPET) that includes PET (glucose 2.27%, 4 h) followed by miniPET (glucose 3.86%, 1 h) was performed in 27 stable continuous ambulatory peritoneal dialysis patients. Ultrafiltration volumes, glucose absorption, ratio of concentration in dialysis fluid to concentration in plasma (D/P), sodium dip (Dip D/P Sodium), free water fraction (FWF60) and the ultrafiltration passing through small pores at 60 min (UFSP60), were calculated using clinical data. Peritoneal transport parameters were estimated using the three-pore model (3p model) and clinical data. Osmotic conductance for glucose was calculated from the parameters of the model. D/P creatinine correlated with diffusive mass transport parameters for all considered solutes, but not with fluid transport characteristics. Hydraulic permeability (L(p)S) correlated with net ultrafiltration from miniPET, UFSP60, FWF60 and sodium dip. The fraction of ultrasmall pores correlated with FWF60 and sodium dip. The sequential PET described and interpreted mechanisms of ultrafiltration and solute transport. Fluid transport parameters from the 3p model were independent of the PET D/P creatinine, but correlated with fluid transport characteristics from PET and miniPET.

  18. Simulative design in macroscale for prospective application to micro-catheters.

    PubMed

    Ha, Cheol Woo

    2018-02-09

    In this paper, a motion-transforming element is applied to the development of a new catheter device. The motion-transforming element structure allows a reduction of linear movement and converts linear movement to rotational movement. The simulative design of micro-catheters is based on a proposed structure called the Operating Mini Station (OMS). OMS is operated by movement of a motion-transforming element. A new motion-transforming element is designed using multiple links that are connected by hinged joints based on an elastic design. The design of the links and the hinges are optimized for precise and reliable movement of the motion-transforming element. Because of the elastic design, it is possible to realize a catheter that allows various movements in small spaces like capillaries.

  19. A Method for Estimating Noise from Full-Scale Distributed Exhaust Nozzles

    NASA Technical Reports Server (NTRS)

    Kinzie, Kevin W.; Schein, David B.

    2004-01-01

    A method to estimate the full-scale noise suppression from a scale model distributed exhaust nozzle (DEN) is presented. For a conventional scale model exhaust nozzle, Strouhal number scaling using a scale factor related to the nozzle exit area is typically applied that shifts model scale frequency in proportion to the geometric scale factor. However, model scale DEN designs have two inherent length scales. One is associated with the mini-nozzles, whose size do not change in going from model scale to full scale. The other is associated with the overall nozzle exit area which is much smaller than full size. Consequently, lower frequency energy that is generated by the coalesced jet plume should scale to lower frequency, but higher frequency energy generated by individual mini-jets does not shift frequency. In addition, jet-jet acoustic shielding by the array of mini-nozzles is a significant noise reduction effect that may change with DEN model size. A technique has been developed to scale laboratory model spectral data based on the premise that high and low frequency content must be treated differently during the scaling process. The model-scale distributed exhaust spectra are divided into low and high frequency regions that are then adjusted to full scale separately based on different physics-based scaling laws. The regions are then recombined to create an estimate of the full-scale acoustic spectra. These spectra can then be converted to perceived noise levels (PNL). The paper presents the details of this methodology and provides an example of the estimated noise suppression by a distributed exhaust nozzle compared to a round conic nozzle.

  20. Mini-Laparoscopy: Instruments and Economics.

    PubMed

    Shadduck, Phillip P; Paquentin, Eduardo Moreno; Carvalho, Gustavo L; Redan, Jay A

    2015-11-01

    Mini-laparoscopy (Mini) was pioneered more than 20 years ago, initially with instruments borrowed from other specialties and subsequently with tools designed specifically for Mini. Early adoption of Mini was inhibited though by the limitations of these first-generation instruments, especially functionality and durability. Newer generation Mini instruments have recently become available with improved effector tips, a choice of shaft diameters and lengths, better shaft insulation and electrosurgery capability, improved shaft strength and rotation, more ergonomic handles, low-friction trocar options, and improved instrument durability. Improvements are also occurring in imaging and advanced energy for Mini. The current status of mini-laparoscopy instruments and economics are presented.

  1. Right miniparasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations: a propensity-adjusted analysis.

    PubMed

    Chiu, Kuan M; Chen, Robert J; Lin, Tzu Y; Chen, Jer S; Huang, Jin H; Huang, Chun Y; Chu, Shu H

    2016-02-01

    Limited real-world data existed for mini-parasternotomy approach with good sample size in Asian cohorts and most previous studies were eclipsed by case heterogeneity. The goal of this study was to compare safety and quality outcomes of cardiac non-coronary valve operations by mini-parasternotomy and full sternotomy approaches on risk-adjusted basis. METHODS From our hospital database, we retrieved the cases of non-coronary valve operations from 1 January 2005 to 31 December 2012, including re-do, emergent, and combined procedures. Estimated EuroScore-II and propensity score for choosing mini-parasternotomy were adjusted for in the regression models on hospital mortality, complications (pneumonia, stroke, sepsis, etc.), and quality parameters (length of stay, ICU time, ventilator time, etc.). Non-complicated cases, defined as survival to discharge, ventilator use not over one week, and intensive care unit stay not over two weeks, were used for quality parameters. There were 283 mini-parasternotomy and 177 full sternotomy cases. EuroScore-II differed significantly (medians 2.1 vs. 4.7, P<0.001). Propensity scores for choosing mini-parasternotomy were higher with lower EuroScore-II (OR=0.91 per 1%, P<0.001), aortic regurgitation (OR=2.3, P=0.005), and aortic non-mitral valve disease (OR=3.9, P<0.001). Adjusted for propensity score and EuroScore-II, mini-parasternotomy group had less pneumonia (OR=0.32, P=0.043), less sepsis (OR=0.31, P=0.045), and shorter non-complicated length of stay (coefficient=-7.2 (day), P<0.001) than full sternotomy group, whereas Kaplan-Meier survival, non-complicated ICU time, non-complicated ventilator time, and 30-day mortality did not differ significantly. The propensity-adjusted analysis demonstrated encouraging safety and quality outcomes for mini-parasternotomy valve operation in carefully selected patients.

  2. Nanostructured severe plastic deformation processed titanium for orthodontic mini-implants.

    PubMed

    Serra, Glaucio; Morais, Liliane; Elias, Carlos Nelson; Semenova, Irina P; Valiev, Ruslan; Salimgareeva, Gulnaz; Pithon, Matheus; Lacerda, Rogério

    2013-10-01

    Titanium mini-implants have been successfully used as anchorage devices in Orthodontics. Commercially pure titanium (cpTi) was recently replaced by Ti-6Al-4V alloy as the mini-implant material base due to the higher strength properties of the alloy. However, the lower corrosion resistance and the lower biocompatibility have been lowering the success rate of Ti-6Al-4V mini-implants. Nanostructured titanium (nTi) is commercially pure titanium that was nanostructured by a specific technique of severe plastic deformation. It is bioinert, does not contain potentially toxic or allergic additives, and has higher specific strength properties than any other titanium applied in medical implants. The higher strength properties associated to the higher biocompatibility make nTi potentially useful for orthodontic mini-implant applications, theoretically overcoming cpTi and Ti-6Al-4V mini-implants. The purposes of the this work were to process nTi, to mechanically compare cpTi, Ti-6Al-4V, and nTi mini-implants by torque test, and to evaluate both the surface morphology and the fracture surface characteristics of them by SEM. Torque test results showed significant increase in the maximum torque resistance of nTi mini-implants when compared to cpTi mini-implants, and no statistical difference between Ti-6Al-4V and nTi mini-implants. SEM analysis demonstrated smooth surface morphology and transgranular fracture aspect for nTi mini-implants. Since nanostructured titanium mini-implants have mechanical properties comparable to titanium alloy mini-implants, and biocompatibility comparable to commercially pure titanium mini-implants, it is suggestive that nanostructured titanium can replace Ti-6Al-4V alloy as the material base for mini-implants. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Lunar Crater Mini-Wakes: Structure, Variability, and Volatiles

    NASA Technical Reports Server (NTRS)

    Zimmerman, Michael I.; Jackson, T. L.; Farrell, W. M.; Stubbs, T. J.

    2012-01-01

    Within a permanently shadowed lunar crater the horizontal flow of solar wind is obstructed by upstream topography, forming a regional plasma mini-wake. In the present work kinetic simulations are utilized to investigate how the most prominent structural aspects of a crater mini-wake are modulated during passage of a solar storm. In addition, the simulated particle fluxes are coupled into an equivalent-circuit model of a roving astronaut,. including triboelectric charging due to frictional contact with the lunar regolith, to characterize charging of the astronaut suit during the various stages of the storm. In some cases, triboelectric charging of the astronaut suit becomes effectively perpetual, representing a critical engineering concern for roving within shadowed lunar regions. Finally, the present results suggest that wake structure plays a critical role in modulating the spatial distribution of volatiles at the lunar poles.

  4. Evidence for the Magnetic Breakout Model in an Equatorial Coronal-Hole Jet

    NASA Astrophysics Data System (ADS)

    Karpen, Judith T.; Kumar, Pankaj; Antiochos, Spiro K.; Wyper, Peter; DeVore, C. Richard

    2017-08-01

    We have analyzed an equatorial coronal-hole jet observed by SDO/AIA on 09 January 2014. The source-region magnetic field structure is consistent with the embedded-bipole topology that we identified and modeled previously as a source of coronal jets (Pariat et al. 2009, 2010, 2015, 2016; Karpen et al. 2017; Wyper et al. 2016). Initial brightenings were observed below a small but distinct “mini-filament” about 25 min before jet onset. A bright circular structure, interpreted as magnetic flux rope (MFR), surrounded the mini-filament. The MFR and filament rose together slowly at first, with a speed of ˜15 km s-1. When bright footpoints and loops appeared below, analogous to flare ribbons and arcade, the MFR/mini-filament rose rapidly (˜126 km s-1), and a bright elongated feature interpreted as a current sheet appeared between the MFR and the growing arcade. Multiple plasmoids propagating upward (˜135 km s-1) and downward (˜55 km s-1) were detected in this sheet. The jet was triggered when the rising MFR interacted with the overlying magnetic structure, most likely at a stressed magnetic null distorted into a current sheet. This event thus exhibits clear evidence of “flare” reconnection below the MFR as well as breakout reconnection above it, consistent with the breakout model for a wide range of solar eruptions (Antiochos et al. 1999; Devore & Antiochos 2008; Karpen et al. 2012; Wyper et al. 2017). Breakout reconnection destroyed the MFR and enabled the entrained coronal plasma and mini-filament to escape onto open field lines, producing an untwisting jet. SDO/HMI magnetograms reveal small footpoint motions at the eruption site and its surroundings, but do not show significant flux emergence or cancellation during or 1-2 hours before the eruption. Therefore, the free energy powering this jet most likely originated in magnetic shear concentrated at the polarity inversion line within the embedded bipole - a mini-filament channel - possibly created by helicity condensation (Antiochos 2013; Knizhnik et al. 2015, 2017).This work was supported in part by a grant from the NASA H-SR program and the NASA Postdoctoral Program.

  5. Emerging links between the biological clock and the DNA damage response.

    PubMed

    Collis, Spencer J; Boulton, Simon J

    2007-08-01

    For life forms to survive, they must adapt to their environmental conditions. One such factor that impacts on both prokaryotic and eukaryotic organisms is the light-dark cycle, a consequence of planetary rotation in relation to our sun. In mammals, the daily light cycle has affected the regulation of many cellular processes such as sleep-wake and calorific intake activities, hormone secretion, blood pressure and immune system responses. Such rhythmic behaviour is the consequence of circadian rhythm/biological clock (BC) systems which are controlled in a light stimulus-dependent manner by a master clock called the suprachiasmatic nucleus (SCN) situated within the anterior hypothalamus. Peripheral clocks located in other organs such as the liver and kidneys relay signals from the SCN, which ultimately leads to tightly controlled expression of several protein families that in turn act on a broad range of cellular functions. Work in lower organisms has demonstrated a link between aging processes and BC factors, and studies in both animal models and clinical trials have postulated a role for certain BC-associated proteins in tumourigenesis and cancer progression. Recent exciting data reported within the last year or so have now established a molecular link between specific BC proteins and factors that control the mammalian cell cycle and DNA damage checkpoints. This mini review will focus on these discoveries and emphasise how such BC proteins may be involved, through their interplay with cell cycle/DNA damage response pathways, in the development of human disease such as cancer.

  6. Spatial variation of permittivity of an electrolyte solution in contact with a charged metal surface: a mini review

    PubMed Central

    Gongadze, E.; van Rienen, U.; Kralj-Iglič, V.; Iglič, A.

    2012-01-01

    Contact between a charged metal surface and an electrolyte implies a particular ion distribution near the charged surface, i.e. the electrical double layer. In this mini review, different mean-field models of relative (effective) permittivity are described within a simple lattice model, where the orientational ordering of water dipoles in the saturation regime is taken into account. The Langevin-Poisson-Boltzmann (LPB) model of spatial variation of the relative permittivity for point-like ions is described and compared to a more general Langevin-Bikerman (LB) model of spatial variation of permittivity for finite-sized ions. The Bikerman model and the Poisson-Boltzmann model are derived as limiting cases. It is shown that near the charged surface, the relative permittivity decreases due to depletion of water molecules (volume-excluded effect) and orientational ordering of water dipoles (saturation effect). At the end, the LPB and LB models are generalised by also taking into account the cavity field. PMID:22263808

  7. Structure-Function Model for Kissing Loop Interactions That Initiate Dimerization of Ty1 RNA

    PubMed Central

    Gamache, Eric R.; Doh, Jung H.; Ritz, Justin; Laederach, Alain; Bellaousov, Stanislav; Mathews, David H.; Curcio, M. Joan

    2017-01-01

    The genomic RNA of the retrotransposon Ty1 is packaged as a dimer into virus-like particles. The 5′ terminus of Ty1 RNA harbors cis-acting sequences required for translation initiation, packaging and initiation of reverse transcription (TIPIRT). To identify RNA motifs involved in dimerization and packaging, a structural model of the TIPIRT domain in vitro was developed from single-nucleotide resolution RNA structural data. In general agreement with previous models, the first 326 nucleotides of Ty1 RNA form a pseudoknot with a 7-bp stem (S1), a 1-nucleotide interhelical loop and an 8-bp stem (S2) that delineate two long, structured loops. Nucleotide substitutions that disrupt either pseudoknot stem greatly reduced helper-Ty1-mediated retrotransposition of a mini-Ty1, but only mutations in S2 destabilized mini-Ty1 RNA in cis and helper-Ty1 RNA in trans. Nested in different loops of the pseudoknot are two hairpins with complementary 7-nucleotide motifs at their apices. Nucleotide substitutions in either motif also reduced retrotransposition and destabilized mini- and helper-Ty1 RNA. Compensatory mutations that restore base-pairing in the S2 stem or between the hairpins rescued retrotransposition and RNA stability in cis and trans. These data inform a model whereby a Ty1 RNA kissing complex with two intermolecular kissing-loop interactions initiates dimerization and packaging. PMID:28445416

  8. Nutrigenomics and its role in male puberty of cattle: a mini review.

    PubMed

    Deb, Rajib; Chakraborty, Sandip; Mahima; Verma, Amit Kumar; Tiwari, Rruchi; Dhama, Kuldeep

    2014-02-01

    Nutrigenomics a novel era in genomics research is based on puzzling issue on how nutrition and genes re-interacts. Perusal of literature reveals that very few information are available in this field and especially when it is associated with puberty in cattle which is a multigenic trait of great economic importance. Thus it opens a new area of research interest. Various markers like-gonadotropin releasing hormone/GNRH (responsible for sexual differentiation and reproduction), interstitial growth regulating factor/IGF1 (having signal controlling reproduction function linked to somatic growth); circulating metabolic hormones viz., leptin apart from GnRH and IGF1 (having impact on testicular development in peripubertal bull) are proved to be associated with male puberty in cattle. Various minerals (copper, selenium, manganese, zinc, chromium, iron and molybdenum) and vitamins (Vit. A, D, E and C) are directly or indirectly linked to male puberty. But no research till today initiated how the nutrients effect on the transcriptome/proteome/metabolome level of marker genes associated with male puberty in cattle. Application of nanotechnology to make food safer for promotion of good health has created much excitement and nanoparticles has been developed against infectious diseases (e.g., Campylobacteriosis) affecting puberty along with certain nanocarriers that can facilitate the uptake of essential nutrients associated with puberty. Much of nutrigenomics research is however in infancy and hence the present mini-review will allow building the concept among researchers and scientists to initiate research in this interesting area.

  9. Construction of trypanosome artificial mini-chromosomes.

    PubMed Central

    Lee, M G; E, Y; Axelrod, N

    1995-01-01

    We report the preparation of two linear constructs which, when transformed into the procyclic form of Trypanosoma brucei, become stably inherited artificial mini-chromosomes. Both of the two constructs, one of 10 kb and the other of 13 kb, contain a T.brucei PARP promoter driving a chloramphenicol acetyltransferase (CAT) gene. In the 10 kb construct the CAT gene is followed by one hygromycin phosphotransferase (Hph) gene, and in the 13 kb construct the CAT gene is followed by three tandemly linked Hph genes. At each end of these linear molecules are telomere repeats and subtelomeric sequences. Electroporation of these linear DNA constructs into the procyclic form of T.brucei generated hygromycin-B resistant cell lines. In these cell lines, the input DNA remained linear and bounded by the telomere ends, but it increased in size. In the cell lines generated by the 10 kb construct, the input DNA increased in size to 20-50 kb. In the cell lines generated by the 13 kb constructs, two sizes of linear DNAs containing the input plasmid were detected: one of 40-50 kb and the other of 150 kb. The increase in size was not the result of in vivo tandem repetitions of the input plasmid, but represented the addition of new sequences. These Hph containing linear DNA molecules were maintained stably in cell lines for at least 20 generations in the absence of drug selection and were subsequently referred to as trypanosome artificial mini-chromosomes, or TACs. Images PMID:8532534

  10. miniTri Mantevo miniapp v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, Johathan; Stark, Dylan; Wolf, Michael

    2016-02-02

    miniTri is a miniapplication developed as part of the Mantevo project. Given a graph, miniTri enumerates all triangles in this graph and computes a metric for each triangle based on the triangle edge and vertex degree. The output of miniTri is a summary of this metric. miniTri mimics the computational requirements of an important set of data science applications. Several approaches to this problem are included in the miniTri software.

  11. [Effect of formula of removing both phlegm and blood stasis in improving cardiac function of Chinese mini-swine with coronary heart disease of phlegm-stasis cementation syndrome].

    PubMed

    Li, Lei; Lin, Cheng-Ren; Ren, Jian-Xun; Miao, Lan; Yao, Ming-Jiang; Li, Dan; Shi, Yue; Ma, Yan-Lei; Fu, Jian-Hua; Liu, Jian-Xun

    2014-02-01

    To evaluate that the effect of formula of removing both phlegm and blood stasis in improving cardiac function of Chinese mini-swine with coronary heart disease of phlegm-stasis cementation syndrome. Totally 36 Chinese mini-swine were randomly divided to six groups: the normal control group, the model group, the Danlou tablet group, and Tanyu Tonzhi Fang(TYTZ) groups with doses of 2. 0, 1. 0 and 0. 5 g kg-1, with six in each group. Except for the normal control group, all of other groups were fed with high-fat diet for 2 weeks. Interventional balloons are adopted to injure their left anterior descending artery endothelium. After the operation, they were fed with high-fat diet for 8 weeks to prepare the coronary heart disease model of phlegm-stasis cementation syndrome. After the operation, they were administered with drugs for 8 weeks. The changes in the myocardial ischemia were observed. The changes in the cardiac function and structure were detected by cardiac ultrasound and noninvasive hemodynamic method. Compared with the normal control group, the model group showed significant increase in myocardial ischemia and SVR and obvious decrease in CO, SV and LCW in noninvasive hemodynamic parameters (P <0.05 or P <0.01). The ultrasonic cardiogram indicated notable decrease in IVSd, LVPWs, EF and FS, and remarkable increase in LVIDs (P<0. 05 orP<0.01). Compared with the model group, TYTZ could reduce the myocardial ischemia, strengthen cardiac function, and improve the abnormal cardiac structure and function induced by ischemia (P <0. 05 or P <0. 01). TYTZ shows a significant effect in improving cardiac function of Chinese mini-swine with coronary heart disease of phlegm-stasis cementation syndrome. The clinical cardiac function detection method could be adopted to correctly evaluate the changes in the post-myocardial ischemia cardiac function, and narrow the gap between clinical application and basic experimental studies.

  12. Scotland: inequalities in women's reproductive health.

    PubMed

    1999-01-01

    This document reports a detailed information on the link between women's poverty and the provision of health care services in Glasgow, Scotland. Glasgow, Scotland was known as the second city of the British Empire and in spite of its wealth, a great number of its population suffers from poverty. In the 1990s, as a response to the inadequate health services provided to the impoverished women, the Family Planning and Sexual Health Directorate included the health needs of the city's female population. It emphasized three main areas of care: improved access, preventive health, and promotion of women's well-being. Seventeen model well-women clinics were conceived to provide a better access, and experts played an active part in the delivery of prioritized health issues through an educational program. An open-ended consultation on major health issues and discrete referral were utilized for the promotion of the women's emotional well-being. "Women Talking" mini-mags produced in 1993 which tackles issues relevant to women's health and the Women's Reproductive Health Services provide multidisciplinary approach offering reproductive health care to women who have social and health problems. This strategic response of Glasgow to these women had facilitated awareness on the links between the social and economic factors, and a confirmation that a continued availability of such appropriate services would prove beneficial to women with severe social problems.

  13. Internal Structure of Mini-CEX Scores for Internal Medicine Residents: Factor Analysis and Generalizability

    ERIC Educational Resources Information Center

    Cook, David A.; Beckman, Thomas J.; Mandrekar, Jayawant N.; Pankratz, V. Shane

    2010-01-01

    The mini-CEX is widely used to rate directly observed resident-patient encounters. Although several studies have explored the reliability of mini-CEX scores, the dimensionality of mini-CEX scores is incompletely understood. Objective: Explore the dimensionality of mini-CEX scores through factor analysis and generalizability analysis. Design:…

  14. A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science

    PubMed Central

    Nosouhian, Saeid; Rismanchian, Mansour; Sabzian, Roya; Shadmehr, Elham; Badrian, Hamid; Davoudi, Amin

    2015-01-01

    The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on orthodontic science, briefly. The searching category was performed on the Pubmed using MeSH words such as “dental (mini) implants, orthodontic anchorage procedures, and orthodontic appliances.” After preliminary sketch, they were grouped as follow: Those evaluating (a) common appliances for providing orthodontic anchorage, (b) biomechanical details of mini-implants and their insertion, (c) clinical application of mini-implants for orthognathic treatments, (d) limitations and possible complications. In conclusion, mini-implant evolved the orthodontic treatment plans and compromised the required orthognathic surgery. Malocclusion treatment and pure orthodontic or orthopedic movements in the three-dimensions have become recently possible by using mini-implant to provide skeletal anchorage. PMID:26225113

  15. Mini-columns for Conducting Breakthrough Experiments. Design and Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dittrich, Timothy M.; Reimus, Paul William; Ware, Stuart Douglas

    Experiments with moderately and strongly sorbing radionuclides (i.e., U, Cs, Am) have shown that sorption between experimental solutions and traditional column materials must be accounted for to accurately determine stationary phase or porous media sorption properties (i.e., sorption site density, sorption site reaction rate coefficients, and partition coefficients or K d values). This report details the materials and construction of mini-columns for use in breakthrough columns to allow for accurate measurement and modeling of sorption parameters. Material selection, construction techniques, wet packing of columns, tubing connections, and lessons learned are addressed.

  16. Dark Matter Search in a Proton Beam Dump with MiniBooNE

    NASA Astrophysics Data System (ADS)

    Aguilar-Arevalo, A. A.; Backfish, M.; Bashyal, A.; Batell, B.; Brown, B. C.; Carr, R.; Chatterjee, A.; Cooper, R. L.; deNiverville, P.; Dharmapalan, R.; Djurcic, Z.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Grange, J.; Green, J. A.; Huelsnitz, W.; de Icaza Astiz, I. L.; Karagiorgi, G.; Katori, T.; Ketchum, W.; Kobilarcik, T.; Liu, Q.; Louis, W. C.; Marsh, W.; Moore, C. D.; Mills, G. B.; Mirabal, J.; Nienaber, P.; Pavlovic, Z.; Perevalov, D.; Ray, H.; Roe, B. P.; Shaevitz, M. H.; Shahsavarani, S.; Stancu, I.; Tayloe, R.; Taylor, C.; Thornton, R. T.; Van de Water, R.; Wester, W.; White, D. H.; Yu, J.; MiniBooNE-DM Collaboration

    2017-06-01

    The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86 ×1 020 protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the dark matter cross section parameter, Y =ɛ2αD(mχ/mV)4≲10-8 , for αD=0.5 and for dark matter masses of 0.01

  17. Laboratory Simulations of Haze Formation in the Atmospheres of Super-Earths and Mini-Neptunes: Particle Color and Size Distribution

    NASA Astrophysics Data System (ADS)

    He, Chao; Hörst, Sarah M.; Lewis, Nikole K.; Yu, Xinting; Moses, Julianne I.; Kempton, Eliza M.-R.; McGuiggan, Patricia; Morley, Caroline V.; Valenti, Jeff A.; Vuitton, Véronique

    2018-03-01

    Super-Earths and mini-Neptunes are the most abundant types of planets among the ∼3500 confirmed exoplanets, and are expected to exhibit a wide variety of atmospheric compositions. Recent transmission spectra of super-Earths and mini-Neptunes have demonstrated the possibility that exoplanets have haze/cloud layers at high altitudes in their atmospheres. However, the compositions, size distributions, and optical properties of these particles in exoplanet atmospheres are poorly understood. Here, we present the results of experimental laboratory investigations of photochemical haze formation within a range of planetary atmospheric conditions, as well as observations of the color and size of produced haze particles. We find that atmospheric temperature and metallicity strongly affect particle color and size, thus altering the particles’ optical properties (e.g., absorptivity, scattering, etc.); on a larger scale, this affects the atmospheric and surface temperature of the exoplanets, and their potential habitability. Our results provide constraints on haze formation and particle properties that can serve as critical inputs for exoplanet atmosphere modeling, and guide future observations of super-Earths and mini-Neptunes with the Transiting Exoplanet Survey Satellite, the James Webb Space Telescope, and the Wide-Field Infrared Survey Telescope.

  18. Dark Matter Search in a Proton Beam Dump with MiniBooNE.

    PubMed

    Aguilar-Arevalo, A A; Backfish, M; Bashyal, A; Batell, B; Brown, B C; Carr, R; Chatterjee, A; Cooper, R L; deNiverville, P; Dharmapalan, R; Djurcic, Z; Ford, R; Garcia, F G; Garvey, G T; Grange, J; Green, J A; Huelsnitz, W; de Icaza Astiz, I L; Karagiorgi, G; Katori, T; Ketchum, W; Kobilarcik, T; Liu, Q; Louis, W C; Marsh, W; Moore, C D; Mills, G B; Mirabal, J; Nienaber, P; Pavlovic, Z; Perevalov, D; Ray, H; Roe, B P; Shaevitz, M H; Shahsavarani, S; Stancu, I; Tayloe, R; Taylor, C; Thornton, R T; Van de Water, R; Wester, W; White, D H; Yu, J

    2017-06-02

    The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86×10^{20} protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the dark matter cross section parameter, Y=ε^{2}α_{D}(m_{χ}/m_{V})^{4}≲10^{-8}, for α_{D}=0.5 and for dark matter masses of 0.01

  19. Influence of Manual Screwdriver Design in Combination With and Without Predrilling on Insertion Torque of Orthodontic Mini-Implants.

    PubMed

    Katalinic, Andrej; Trinajstic Zrinski, Magda; Roksandic Vrancic, Zlatka; Spalj, Stjepan

    2017-02-01

    The study focused on the influence of screwdriver design in combination with and without predrilling a pilot hole of inner implant diameter on insertion torque of orthodontic mini-implants, controlling for cortical thickness and vertical insertion force as cofactors. One hundred twenty mini-implants (Forestadent) of 1.7 mm in diameter and 6 and 8 mm in length were manually inserted into 120 swine rib bone samples. Maximal insertion torque as a measure of primary stability and vertical force were measured. The study included procedures with and without pilot hole and different screwdriver handles and shaft length and 2 implant lengths. Design of manual screwdriver does not modify insertion torque to a significant extent. In multiple linear regression model, significant predictors of insertion torque are thicker cortical bone (explaining 16.6% of variability), higher vertical force at maximal torque (13.5%), 6-mm implant length (2.5%), and the presence of pilot hole (2.3%). Handle type and shaft length of manual screwdriver do not significantly influence insertion torque, whereas predrilling a pilot hole has low impact on torque values of manually inserted self-drilling orthodontic mini-implants.

  20. Measurement of Muon Neutrino Quasielastic Scattering on Carbon

    NASA Astrophysics Data System (ADS)

    Aguilar-Arevalo, A. A.; Bazarko, A. O.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Green, C.; Green, J. A.; Hart, T. L.; Hawker, E.; Imlay, R.; Johnson, R. A.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Link, J. M.; Liu, Y.; Liu, Y.; Louis, W. C.; Mahn, K. B. M.; Marsh, W.; Martin, P. S.; McGregor, G.; Metcalf, W.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Nelson, R. H.; Nienaber, P.; Ouedraogo, S.; Patterson, R. B.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Schirato, R.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smith, D.; Sorel, M.; Spentzouris, P.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; van de Water, R.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Zeller, G. P.; Zimmerman, E. D.

    2008-01-01

    The observation of neutrino oscillations is clear evidence for physics beyond the standard model. To make precise measurements of this phenomenon, neutrino oscillation experiments, including MiniBooNE, require an accurate description of neutrino charged current quasielastic (CCQE) cross sections to predict signal samples. Using a high-statistics sample of νμ CCQE events, MiniBooNE finds that a simple Fermi gas model, with appropriate adjustments, accurately characterizes the CCQE events observed in a carbon-based detector. The extracted parameters include an effective axial mass, MAeff=1.23±0.20GeV, that describes the four-momentum dependence of the axial-vector form factor of the nucleon, and a Pauli-suppression parameter, κ=1.019±0.011. Such a modified Fermi gas model may also be used by future accelerator-based experiments measuring neutrino oscillations on nuclear targets.

  1. Peak expiratory flow profiles delivered by pump systems. Limitations due to wave action.

    PubMed

    Miller, M R; Jones, B; Xu, Y; Pedersen, O F; Quanjer, P H

    2000-06-01

    Pump systems are currently used to test the performance of both spirometers and peak expiratory flow (PEF) meters, but for certain flow profiles the input signal (i.e., requested profile) and the output profile can differ. We developed a mathematical model of wave action within a pump and compared the recorded flow profiles with both the input profiles and the output predicted by the model. Three American Thoracic Society (ATS) flow profiles and four artificial flow-versus-time profiles were delivered by a pump, first to a pneumotachograph (PT) on its own, then to the PT with a 32-cm upstream extension tube (which would favor wave action), and lastly with the PT in series with and immediately downstream to a mini-Wright peak flow meter. With the PT on its own, recorded flow for the seven profiles was 2.4 +/- 1.9% (mean +/- SD) higher than the pump's input flow, and similarly was 2.3 +/- 2.3% higher than the pump's output flow as predicted by the model. With the extension tube in place, the recorded flow was 6.6 +/- 6.4% higher than the input flow (range: 0.1 to 18.4%), but was only 1.2 +/- 2.5% higher than the output flow predicted by the model (range: -0.8 to 5.2%). With the mini-Wright meter in series, the flow recorded by the PT was on average 6.1 +/- 9.1% below the input flow (range: -23.8 to 2. 5%), but was only 0.6 +/- 3.3% above the pump's output flow predicted by the model (range: -5.5 to 3.9%). The mini-Wright meter's reading (corrected for its nonlinearity) was on average 1.3 +/- 3.6% below the model's predicted output flow (range: -9.0 to 1. 5%). The mini-Wright meter would be deemed outside ATS limits for accuracy for three of the seven profiles when compared with the pump's input PEF, but this would be true for only one profile when compared with the pump's output PEF as predicted by the model. Our study shows that the output flow from pump systems can differ from the input waveform depending on the operating configuration. This effect can be predicted with reasonable accuracy using a model based on nonsteady flow analysis that takes account of pressure wave reflections within pump systems.

  2. Validation of the Mini-OAKHQOL for use in patients with osteoarthritis in Spain.

    PubMed

    Gonzalez Sáenz de Tejada, Marta; Bilbao, Amaia; Herrera, Carmen; García, Lidia; Sarasqueta, Cristina; Escobar, Antonio

    2017-08-01

    The Mini-Osteoarthritis Knee and Hip Quality of Life (Mini-OAKHQOL) questionnaire osteoarthritis is specific to individuals with knee or hip osteoarthritis. The objective of this study was to perform a validation of the Mini-OAKHQOL for use in Spain in terms of its psychometric properties of reliability, validity and responsiveness. Patients with osteoarthritis from the waiting list for a joint replacement completed the OAKHQOL, Short Form 36 Health Survey and Western Ontario and McMaster Universities Osteoarthritis Index. Reliability was assessed in terms of internal consistency and test-retest data, and convergent validity using Spearman's correlation coefficient. Structural validity was investigated by confirmatory factor analysis, and Rasch analysis was used to examine the unidimensionality of the scales. Responsiveness was assessed by calculating effect sizes. Confirmatory factor analysis confirmed the five-factor model, and the results of the Rasch analyses supported the unidimensionality assumption, with infit and outfit statistics. Cronbach's alpha ranged from 0.76 to 0.89 for all except the social dimensions. Statistically significant differences were observed between patients with different degrees of disease severity on all dimensions. There was convergent validity among dimensions expected to be correlated. The OAKHQOL questionnaire showed good responsiveness, with large changes for all dimensions apart from the two social dimensions, which had small effect sizes. Results of the study support the view that the Spanish version of the Mini-OAKHQOL questionnaire is a valid instrument to measure health-related quality of life in patients with osteoarthritis of the lower limb.

  3. NLTE modeling of a small active region filament observed with the VTT

    NASA Astrophysics Data System (ADS)

    Schwartz, P.; Balthasar, H.; Kuckein, C.; Koza, J.; Gömöry, P.; Rybák, J.; Heinzel, P.; Kučera, A.

    2016-11-01

    An active region mini-discretionary-filament was observed with the Vacuum Tower Telescope (VTT) in Tenerife simultaneously in the He I infrared triplet using the Tenerife Infrared Polarimeter 1 (TIP 1), in Hα with the TESOS Fabry-Pérot interferometer, and in Ca II 8542 Å with the VTT spectrograph. The spectropolarimetric data were inverted using the HAZEL code and Hα profiles were modelled by solving a NLTE radiative transfer in a simple isobaric and isothermal 2D slab irradiated both from its bottom and sides from the solar surface. It was found that the mini-discretionary-filament is composed of horizontal fluxtubes, along which the cool plasma of T˜10 000 K can flow with very large, even supersonic, velocities.

  4. Earth Observations taken by Expedition 30 crewmember

    NASA Image and Video Library

    2012-01-01

    ISS030-E-038622 (1 Jan. 2012) --- Framed by a window of the Cupola on the International Space Station is a scene photographed by one of the Expedition 30 crew members aboard the orbital outpost showing two Russian spacecraft that are currently docked to it. A Soyuz (near foreground) is docked to Rassvet, also known as the Mini-Research Module 1 (MRM-1), and a Progress is linked to the Pirs Docking Compartment, just above center frame. Part of Earth, mostly clouds and water, can be seen running horizontally through the scene.

  5. The effects of hormonal contraceptives on glycemic regulation

    PubMed Central

    Cortés, Manuel E.; Alfaro, Andrea A.

    2014-01-01

    A number of side effects have been linked to the use of hormonal contraceptives, among others, alterations in glucose levels. Hence, the objective of this mini-review is to show the main effects of hormonal contraceptive intake on glycemic regulation. First, the most relevant studies on this topic are described, then the mechanisms that might be accountable for this glycemic regulation impairment as exerted by hormonal contraceptives are discussed. Finally, we briefly discuss the ethical responsibility of health professionals to inform about the potential risks on glycemic homeostasis regarding hormonal contraceptive intake. PMID:25249703

  6. Comparison of success rates of orthodontic mini-screws by the insertion method.

    PubMed

    Kim, Jung Suk; Choi, Seong Hwan; Cha, Sang Kwon; Kim, Jang Han; Lee, Hwa Jin; Yeom, Sang Seon; Hwang, Chung Ju

    2012-10-01

    The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.

  7. Self-Determination Theory as a Foundation for Personality Researchers.

    PubMed

    Sheldon, Kennon M; Prentice, Mike

    2017-11-16

    In this introductory article we first describe the impetus for this special issue. What made us think that Self-Determination Theory (SDT) might provide a sort of foundation for the rest of personality psychology? For readers unfamiliar with SDT, we then provide a historical overview which covers the evolution of the six "mini-theories" that currently comprise SDT: cognitive evaluation theory, causality orientations theory, organismic integration theory, basic psychological needs theory, goal contents theory, and relational motivation theory. Following each section are preliminary suggestions about how each mini-theory might be useful or informative in other branches of personality. This special issue contains 9 articles, each of which makes its own attempt to newly link its area of personality research to SDT. Even if SDT is not the appropriate seed for greater consilience in personality psychology, we urge the field not to neglect the search for unifying principles (Sheldon, Chen, & Hilpert, 2011); it may finally be time to renew the search for a "grand theory" in personality. This article is protected by copyright. All rights reserved. © 2017 Wiley Periodicals, Inc.

  8. Contrasting influences of Drosophila white/mini-white on ethanol sensitivity in two different behavioral assays

    PubMed Central

    Chan, Robin F.; Lewellyn, Lara; DeLoyht, Jacqueline M.; Sennett, Kristyn; Coffman, Scarlett; Hewitt, Matthew; Bettinger, Jill C.; Warrick, John M.; Grotewiel, Mike

    2014-01-01

    Background The fruit fly Drosophila melanogaster has been used extensively to investigate genetic mechanisms of ethanol-related behaviors. Many past studies in flies, including studies from our laboratory, have manipulated gene expression using transposons carrying the genetic-phenotypic marker mini-white, a derivative of the endogenous gene white. Whether the mini-white transgenic marker or the endogenous white gene influence behavioral responses to acute ethanol exposure in flies has not been systematically investigated. Methods We manipulated mini-white and white expression via (i) transposons marked with mini-white, (ii) RNAi against mini-white and white and (iii) a null allele of white. We assessed ethanol sensitivity and tolerance using a previously described eRING assay (based on climbing in the presence of ethanol) and an assay based on ethanol-induced sedation. Results In eRING assays, ethanol-induced impairment of climbing correlated inversely with expression of the mini-white marker from a series of transposon insertions. Additionally, flies harboring a null allele of white or flies with RNAi-mediated knockdown of mini-white were significantly more sensitive to ethanol in eRING assays than controls expressing endogenous white or the mini-white marker. In contrast, ethanol sensitivity and rapid tolerance measured in the ethanol sedation assay were not affected by decreased expression of mini-white or endogenous white in flies. Conclusions Ethanol sensitivity measured in the eRING assay is noticeably influenced by white and mini-white, making eRING problematic for studies on ethanol-related behavior in Drosophila using transgenes marked with mini-white. In contrast, the ethanol sedation assay described here is a suitable behavioral paradigm for studies on ethanol sedation and rapid tolerance in Drosophila including those that use widely available transgenes marked with mini-white. PMID:24890118

  9. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment.

    PubMed

    Lee, Jin-Hwa; Choo, Hyeran; Kim, Seong-Hun; Chung, Kyu-Rhim; Giannuzzi, Lucille A; Ngan, Peter

    2011-06-01

    When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. HARP targets pion production cross section and yield measurements: Implications for MiniBooNE neutrino flux

    NASA Astrophysics Data System (ADS)

    Wickremasinghe, Don Athula Abeyarathna

    The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum from 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target positive pion production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of muon neutrino flux predictions for updated SW model is presented.

  11. A cross-sectional study on schistosomiasis and soil-transmitted helminths in Mbita district, western Kenya using different copromicroscopic techniques.

    PubMed

    Ng'etich, Annette I; Rawago, Fredrick O; Jura, Walter G Z O; Mwinzi, Pauline N; Won, Kimberly Y; Odiere, Maurice R

    2016-02-16

    Identification of populations to be targeted for individual treatment and broad-spectrum therapy in schistosomiasis-endemic areas, assessment of therapy efficacy, morbidity, and evaluation of control strategies need to be based on reliable diagnostic tools. Kato-Katz is routinely used and remains the standard diagnostic technique for schistosomiasis, despite its many challenges. This study was conducted in Nyamanga village, Mbita, western Kenya, and evaluated the diagnostic performance of Kato-Katz, Mini-Parasep and modified Mini-FLOTAC techniques in detection of Schistosoma mansoni and soil-transmitted helminths (Ascaris lumbricoides, Trichuris trichiura and hookworm) ova. Stool samples from 132 individuals were screened for eggs of S. mansoni by the 3 techniques. Mini-Parasep faecal parasite concentrator (Apacor Ltd, England), a single-use diagnostic device with a built-in filter for faecal concentration of helminth eggs by sedimentation was employed on stool samples fixed in 10% formalin. A modified Mini-FLOTAC (University of Naples, Italy) was based on floatation of helminths eggs with two different solutions (FS2 and FS7) using a closed system (Fill-FLOTAC) with 5% formalin. Kato-Katz was performed following WHO recommendation. Prevalence of S. mansoni and STH, sensitivity and degree of agreement among the 3 techniques were determined. Prevalence of S. mansoni was 47.0%, 34.1% and 20.5% by Mini-Parasep, Kato-Katz and modified Mini-FLOTAC FS7 techniques, respectively. Prevalence of any STH infection was 6.1%, 3.0%, 6.1% and 6.8% by Mini-Parasep, Kato-Katz, modified Mini-FLOTAC FS2 and modified Mini-FLOTAC FS7 techniques, respectively. Considering the pooled results of the three methods (Mini-Parasep, Kato-Katz and modified Mini-FLOTAC FS7) as diagnostic 'gold' standard, the sensitivity of Mini-Parasep, Kato-Katz and modified Mini-FLOTAC FS7 for S. mansoni was 77.5%, 56.1%, and 33.8%, respectively. Mini-Parasep and modified Mini-FLOTAC FS7 techniques had moderate (κ = 0.46) and fairly good (κ = 0.25) agreements with Kato-Katz for S. mansoni, respectively. Mini-Parasep detected a higher proportion of light intensity S. mansoni infections compared to Kato-Katz, which detected high proportions of heavy infections. Mini-Parasep detected a similar mean number of S. mansoni eggs per gram (EPG) of stool compared to the standard Kato-Katz (62.9 vs 97.3; t (131) = -0.49, P = 0.6265) and significantly higher EPG compared to the modified Mini-FLOTAC FS7 (62.9 vs 34.6; t (131) = 5.39, P < 0.0001). The high sensitivity of Mini-Parasep suggests its promising potential as an alternative tool in enhancing diagnosis and in monitoring schistosomiasis transmission and determining endpoint of intervention programs, especially in low endemicity areas. Mini-Parasep is also easy to operate, safe and also permits work with fresh stool.

  12. Membrane Packing Problems: A short Review on computational Membrane Modeling Methods and Tools

    PubMed Central

    Sommer, Björn

    2013-01-01

    The use of model membranes is currently part of the daily workflow for many biochemical and biophysical disciplines. These membranes are used to analyze the behavior of small substances, to simulate transport processes, to study the structure of macromolecules or for illustrative purposes. But, how can these membrane structures be generated? This mini review discusses a number of ways to obtain these structures. First, the problem will be formulated as the Membrane Packing Problem. It will be shown that the theoretical problem of placing proteins and lipids onto a membrane area differ significantly. Thus, two sub-problems will be defined and discussed. Then, different – partly historical – membrane modeling methods will be introduced. And finally, membrane modeling tools will be evaluated which are able to semi-automatically generate these model membranes and thus, drastically accelerate and simplify the membrane generation process. The mini review concludes with advice about which tool is appropriate for which application case. PMID:24688707

  13. Gamma-Ray Burst Prompt Emission Light Curves and Power Density Spectra in the ICMART Model

    NASA Astrophysics Data System (ADS)

    Zhang, Bo; Zhang, Bing

    2014-02-01

    In this paper, we simulate the prompt emission light curves of gamma-ray bursts (GRBs) within the framework of the Internal-Collision-induced MAgnetic Reconnection and Turbulence (ICMART) model. This model applies to GRBs with a moderately high magnetization parameter σ in the emission region. We show that this model can produce highly variable light curves with both fast and slow components. The rapid variability is caused by many locally Doppler-boosted mini-emitters due to turbulent magnetic reconnection in a moderately high σ flow. The runaway growth and subsequent depletion of these mini-emitters as a function of time define a broad slow component for each ICMART event. A GRB light curve is usually composed of multiple ICMART events that are fundamentally driven by the erratic GRB central engine activity. Allowing variations of the model parameters, one is able to reproduce a variety of light curves and the power density spectra as observed.

  14. Contrasting influences of Drosophila white/mini-white on ethanol sensitivity in two different behavioral assays.

    PubMed

    Chan, Robin F; Lewellyn, Lara; DeLoyht, Jacqueline M; Sennett, Kristyn; Coffman, Scarlett; Hewitt, Matthew; Bettinger, Jill C; Warrick, John M; Grotewiel, Mike

    2014-06-01

    The fruit fly Drosophila melanogaster has been used extensively to investigate genetic mechanisms of ethanol (EtOH)-related behaviors. Many past studies in flies, including studies from our laboratory, have manipulated gene expression using transposons carrying the genetic-phenotypic marker mini-white(mini-w), a derivative of the endogenous gene white(w). Whether the mini-w transgenic marker or the endogenous w gene influences behavioral responses to acute EtOH exposure in flies has not been systematically investigated. We manipulated mini-w and w expression via (i) transposons marked with mini-w, (ii) RNAi against mini-w and w, and (iii) a null allele of w. We assessed EtOH sensitivity and tolerance using a previously described eRING assay (based on climbing in the presence of EtOH) and an assay based on EtOH-induced sedation. In eRING assays, EtOH-induced impairment of climbing correlated inversely with expression of the mini-w marker from a series of transposon insertions. Additionally, flies harboring a null allele of w or flies with RNAi-mediated knockdown of mini-w were significantly more sensitive to EtOH in eRING assays than controls expressing endogenous w or the mini-w marker. In contrast, EtOH sensitivity and rapid tolerance measured in the EtOH sedation assay were not affected by decreased expression of mini-w or endogenous w in flies. EtOH sensitivity measured in the eRING assay is noticeably influenced by w and mini-w, making eRING problematic for studies on EtOH-related behavior in Drosophila using transgenes marked with mini-w. In contrast, the EtOH sensitivity assay described here is a suitable behavioral paradigm for studies on EtOH sensitivity and rapid tolerance in Drosophila including those that use widely available transgenes marked with mini-w. Copyright © 2014 by the Research Society on Alcoholism.

  15. Equilibrium Partitioning Sediment Guidelines (ESGs) for the ...

    EPA Pesticide Factsheets

    ... PLC = partial life-cycle ... 5 ii mini iiiiiiiii iiiiiii mi 1 1 iii mini ii i B : - Benthic vs WQC i— w ~_ ~ _ o° _ -0 ° - - - ii mini iiiiiiiii iiiiiii iiiiiiiii mini ii 0.1 ... PhD thesis. ...

  16. Structural correlates of the creatine transporter function regulation: the undiscovered country.

    PubMed

    Santacruz, Lucia; Jacobs, Danny O

    2016-08-01

    Creatine (Cr) and phosphocreatine constitute an energy shuttle that links ATP production in mitochondria to subcellular locations of ATP consumption. Cells in tissues that are reliant on this energy shuttle, such as myocytes and neurons, appear to have very limited ability to synthesize creatine. Therefore, these cells depend on Cr uptake across the cell membrane by a specialized creatine transporter (CrT solute carrier SLC6A8) in order to maintain intracellular creatine levels. Cr supplementation has been shown to have a beneficial effect in numerous in vitro and in vivo models, particularly in cases of oxidative stress, and is also widely used by athletes as a performance enhancement nutraceutical. Intracellular creatine content is maintained within narrow limits. However, the physiological and cellular mechanisms that mediate Cr transport during health and disease (such as cardiac failure) are not understood. In this narrative mini-review, we summarize the last three decades of research on CrT structure, function and regulation.

  17. Hematite spherules at Meridiani: Results from MI, Mini-TES, and Pancam

    NASA Astrophysics Data System (ADS)

    Calvin, W. M.; Shoffner, J. D.; Johnson, J. R.; Knoll, A. H.; Pocock, J. M.; Squyres, S. W.; Weitz, C. M.; Arvidson, R. E.; Bell, J. F.; Christensen, P. R.; de Souza, P. A.; Farrand, W. H.; Glotch, T. D.; Herkenhoff, K. E.; Jolliff, B. L.; Knudson, A. T.; McLennan, S. M.; Rogers, A. D.; Thompson, S. D.

    2008-12-01

    We report on observations of hematite-bearing spherules at Meridiani Planum made using the Microscopic Imager (MI), Mini-Thermal Emission Spectrometer (Mini-TES), and Panoramic Camera (Pancam) instruments on the Mars Exploration Rover Opportunity. Spherules were observed on soil surfaces and in outcrop rocks, both on undisturbed surfaces and in abraded surfaces ground using the Rock Abrasion Tool (RAT). Spherule size and shape change little along the 850 m eastward traverse from Eagle Crater to Endurance Crater, but spherules decrease and then slightly increase in size along the 6 km traverse from Endurance south to Victoria Crater. Local populations range from submillimeters to several millimeters in diameter. An additional small diameter (100 μm) size population is possible. An increase in irregular shapes is found near Victoria Crater. This, combined with the size decrease south of Endurance, suggests either a changing depositional environment, or variation in the duration and timing of diagenetic events. The dominant smaller size population observed early in the mission in aeolian areas and ripple crests is observed as the primary size population in abraded outcrop farther south. This suggests that successively younger beds are exposed at the surface along the southward traverse. Stratigraphically higher units removed by erosion could be recorded by the present surface lag deposit. Coordinated systematic observations are used to determine optical and infrared hematite indices of the surface soils in Pancam and Mini-TES. In spite of the systematic variation seen in MI, both Pancam and Mini-TES indices are highly variable based on the local surface, and neither show systematic trends south of Endurance. The lack of a 390 cm-1 feature in Mini-TES spectra suggests concentric or radial interior structure within the spherules at scales too fine for MI to observe. Mini-TES does not detect any silicate component in the spherules. A bound water component in soils or in exchange with the atmosphere is observed. These spherules have been previously interpreted as concretions formed within what were once water-saturated, diagenetically altered ``dirty evaporate'' sandstone sediments. Our observations support this interpretation; however, no single terrestrial analog provides a model that can account for all attributes of the spherules on Mars.

  18. Hematite spherules at Meridiani: results from MI, Mini-TES, and Pancam

    USGS Publications Warehouse

    Calvin, W.M.; Shoffner, J.D.; Johnson, J. R.; Knoll, A.H.; Pocock, J.M.; Squyres, S. W.; Weitz, C.M.; Arvidson, R. E.; Bell, J.F.; Christensen, P.R.; de Souza, P. A.; Farrand, W. H.; Glotch, T.D.; Herkenhoff, K. E.; Jolliff, B.L.; Knudson, A.T.; McLennan, S.M.; Rogers, A.D.; Thompson, S.D.

    2008-01-01

    We report on observations of hematite-bearing spherules at Meridiani Planum made using the Microscopic Imager (MI), Mini-Thermal Emission Spectrometer (Mini-TES), and Panoramic Camera (Pancam) instruments on the Mars Exploration Rover Opportunity. Spherules were observed on soil surfaces and in outcrop rocks, both on undisturbed surfaces and in abraded surfaces ground using the Rock Abrasion Tool (RAT). Spherule size and shape change little along the 850 m eastward traverse from Eagle Crater to Endurance Crater, but spherules decrease and then slightly increase in size along the 6 km traverse from Endurance south to Victoria Crater. Local populations range from submillimeters to several millimeters in diameter. An additional small diameter (100 μm) size population is possible. An increase in irregular shapes is found near Victoria Crater. This, combined with the size decrease south of Endurance, suggests either a changing depositional environment, or variation in the duration and timing of diagenetic events. The dominant smaller size population observed early in the mission in aeolian areas and ripple crests is observed as the primary size population in abraded outcrop farther south. This suggests that successively younger beds are exposed at the surface along the southward traverse. Stratigraphically higher units removed by erosion could be recorded by the present surface lag deposit. Coordinated systematic observations are used to determine optical and infrared hematite indices of the surface soils in Pancam and Mini-TES. In spite of the systematic variation seen in MI, both Pancam and Mini-TES indices are highly variable based on the local surface, and neither show systematic trends south of Endurance. The lack of a 390 cm?1 feature in Mini-TES spectra suggests concentric or radial interior structure within the spherules at scales too fine for MI to observe. Mini-TES does not detect any silicate component in the spherules. A bound water component in soils or in exchange with the atmosphere is observed. These spherules have been previously interpreted as concretions formed within what were once water-saturated, diagenetically altered ?dirty evaporate? sandstone sediments. Our observations support this interpretation; however, no single terrestrial analog provides a model that can account for all attributes of the spherules on Mars.

  19. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI).

    PubMed

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-05-22

    There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.

  20. Mini-TES Observations of Comanche Carbonate and Its Distribution

    NASA Technical Reports Server (NTRS)

    Ruff, Steven W.; Morris, Richard V.

    2010-01-01

    The discovery by the Spirit rover of outcrops rich in Mg-Fe carbonate [Morris et al., 2010] represents another manifestation of a diverse aqueous history in Gusev crater. In 2005, observations by the Moessbauer spectrometer (MB) on outcrops dubbed Comanche provided initial indication of Fe-Mg carbonate that was subsequently supported by analysis of elemental data from the Alpha Particle X-ray Spectrometer (APXS). The recognition of a carbonate component in thermal infrared spectra measured by the Miniature Thermal Emission Spectrometer (Mini-TES) was significantly delayed due to dust contamination of the instrument's optics. With the implementation of a viable dust correction, the Comanche spectra were revisited and presented clear and compelling evidence for a Mg-Fe carbonate component that could be as much as a third of the total mineral abundance. The data from all three instruments in combination are best matched by Mg-Fe carbonate with an abundance of 16-34 wt%. Mini-TES spectra were acquired for 12 targets at various locations on the Comanche (4-5 m long) and Comanche Spur (1-2 m long) outcrops, the latter being the location of the MB and APXS measurements. The two outcrops are spectrally comparable and share similar morphology and texture based on color images from the Panoramic Camera (Pancam). The highest quality Mini-TES spectrum comes from the larger Comanche outcrop on a target named Saupitty. Linear least squares modeling of the Saupitty spectrum employed a library of laboratory spectra tailored for consistency with the APXS and MB data and included spectra representing Martian dust, a slope spectrum to account for any temperature determination errors, and a blackbody spectrum to account for differences in spectral contrast between the laboratory and Mini-TES spectrum. Successful modeling of the Comanche Saupitty spectrum required one or more carbonate phases to obtain a good fit. Excluding all carbonates from the full starting library more than doubled the root-mean-squared error of the model fit (0.147% vs. 0.299%). Because Mg-Fe carbonate and Ca-Mg carbonate (dolomite) are so spectrally similar over the range used for modeling, both provide a comparable fit. However, Carich carbonates like dolomite are precluded based on APXS data and are inconsistent with MB results. The Comanche carbonate rocks are stratigraphically above a set of olivine-rich volcaniclastic rocks known as Algonquin class that mantle the Haskin Ridge feature of the Columbia Hills. Based on 50 Mini-TES observations, the Comanche outcrops are the only rocks that host abundant carbonate. However, a target at the base of the larger Comanche outcrop appears spectrally transitional between the carbonate and olivine units. This transitional spectral character applies to additional outcrops a few 10s of meters away from Comanche that also appear stratigraphically transitional. Additional work will attempt to establish whether we are seeing an alteration horizon or depositional unit associated with the emplacement Comanche carbonate.

  1. ObsPy - A Python Toolbox for Seismology - and Applications

    NASA Astrophysics Data System (ADS)

    Krischer, L.; Megies, T.; Barsch, R.; MacCarthy, J.; Lecocq, T.; Koymans, M. R.; Carothers, L.; Eulenfeld, T.; Reyes, C. G.; Falco, N.; Sales de Andrade, E.

    2017-12-01

    Recent years witnessed the evolution of Python's ecosystem into one of the most powerful and productive scientific environments across disciplines. ObsPy (https://www.obspy.org) is a fully community driven, open-source project dedicated to provide a bridge for seismology into that ecosystem. It is a Python toolbox offering: Read and write support for essentially every commonly used data format in seismology with a unified interface and automatic format detection. This includes waveform data (MiniSEED, SAC, SEG-Y, Reftek, …) as well as station (SEED, StationXML, SC3ML, …) and event meta information (QuakeML, ZMAP, …). Integrated access to the largest data centers, web services, and real-time data streams (FDSNWS, ArcLink, SeedLink, ...). A powerful signal processing toolbox tuned to the specific needs of seismologists. Utility functionality like travel time calculations with the TauP method, geodetic functions, and data visualizations. ObsPy has been in constant development for more than eight years and is developed and used by scientists around the world with successful applications in all branches of seismology. Additionally it nowadays serves as the foundation for a large number of more specialized packages. Newest features include: Full interoperability of SEED and StationXML/Inventory objects Access to the Nominal Response Library (NRL) for easy and quick creation of station metadata from scratch Support for the IRIS Federated Catalog Service Improved performance of the EarthWorm client Several improvements to MiniSEED read/write module Improved plotting capabilities for PPSD (spectrograms, PSD of discrete frequencies over time, ..) Support for.. Reading ArcLink Inventory XML Reading Reftek data format Writing SeisComp3 ML (SC3ML) Writing StationTXT format This presentation will give a short overview of the capabilities of ObsPy and point out several representative or new use cases and show-case some projects that are based on ObsPy, e.g.: seismo-live.org Seedlink-plotter MSNoise, and others..

  2. Reasons for mini-implants failure: choosing installation site should be valued!

    PubMed Central

    Consolaro, Alberto; Romano, Fábio Lourenço

    2014-01-01

    Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a) Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b) Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c) The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d) The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e) 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1) Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2) Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3) Low bone density, low thickness and low alveolar bone volume; 4) Low alveolar cortical bone thickness; 5) Excessive pressure inducing trabecular bone microfracture; 6) Sites of higher anatomical weakness in the mandible and the maxilla; 7) Thicker gingival tissue not considered when choosing the mini-implant. PMID:24945511

  3. The Argonaute protein TbAGO1 contributes to large and mini-chromosome segregation and is required for control of RIME retroposons and RHS pseudogene-associated transcripts.

    PubMed

    Durand-Dubief, Mickaël; Absalon, Sabrina; Menzer, Linda; Ngwabyt, Sandra; Ersfeld, Klaus; Bastin, Philippe

    2007-12-01

    The protist Trypanosoma brucei possesses a single Argonaute gene called TbAGO1 that is necessary for RNAi silencing. We previously showed that in strain 427, TbAGO1 knock-out leads to a slow growth phenotype and to chromosome segregation defects. Here we report that the slow growth phenotype is linked to defects in segregation of both large and mini-chromosome populations, with large chromosomes being the most affected. These phenotypes are completely reversed upon inducible re-expression of TbAGO1 fused to GFP, demonstrating their link with TbAGO1. Trypanosomes that do not express TbAGO1 show a general increase in the abundance of transcripts derived from the short retroposon RIME (Ribosomal Interspersed Mobile Element). Supplementary large RIME transcripts emerge in the absence of RNAi, a phenomenon coupled to the disappearance of short transcripts. These fluctuations are reversed by inducible expression of GFP::TbAGO1. Furthermore, we use a combination of Northern blots, RT-PCR and sequencing to reveal that RNAi controls expression of transcripts derived from RHS (Retrotransposon Hot Spot) pseudogenes (RHS genes with retro-element(s) integrated within their coding sequence). Absence of RNAi also leads to an increase of steady-state transcripts from regular RHS genes (those without retro-element), indicating a role for pseudogene in control of gene expression. However, analysis of retroposon abundance and arrangement in the genome of multiple clonal cell lines of TbAGO1-/- failed to reveal movement of mobile elements despite the increased amounts of retroposon transcripts.

  4. Efficient production of native lunasin with correct N-terminal processing by using the pH-induced self-cleavable Ssp DnaB mini-intein system in Escherichia coli.

    PubMed

    Setrerrahmane, Sarra; Zhang, Yi; Dai, Guangzhi; Lv, Jing; Tan, Shuhua

    2014-09-01

    To develop an efficient and cost-effective approach for the production of small preventive peptide lunasin with correct natural N terminus, a synthetic gene was designed by OPTIMIZER & Gene Designer and cloned into pTWIN1 vector at SapI and PstI sites. Thus, lunasin was N-terminally fused to the pH-induced self-cleavable Ssp DnaB mini-intein linked to a chitin binding domain (CBD) with no extra residues. The resultant fusion protein was highly expressed by lactose induction in Escherichia coli BL21 (DE3) in a 7-l bioreactor and bound to a chitin affinity column. After washing the impurities, the Ssp DnaB intein mediated on-column self-cleavage was easily triggered by shifting pH and temperature to allow the native lunasin released. The final purified lunasin yielded up to 75 mg/l medium. Tricine/SDS-PAGE and matrix-assisted laser desorption time-of-flight (MALDI-TOF)/mass spectrometry (MS) verified the structural authenticity of the product, implying the correct cleavage at the junction between Ssp DnaB intein and lunasin. MTT assay confirmed its potent proliferation inhibitory activity to human cancer cells HCT-116 and MDA-MB-231; however, no cytotoxicity to normal human lens epithelial cell SRA01/04 and hepatoma HepG2. Taken together, we provide a novel strategy to produce recombinant native lunasin with correct N-terminal processing by using the pH-induced self-cleavable Ssp DnaB mini-intein.

  5. Search for Muon Neutrino and Antineutrino Disappearance in MiniBooNE

    NASA Astrophysics Data System (ADS)

    Aguilar-Arevalo, A. A.; Anderson, C. E.; Bazarko, A. O.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Grange, J.; Green, C.; Green, J. A.; Hart, T. L.; Hawker, E.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Linden, S. K.; Link, J. M.; Liu, Y.; Liu, Y.; Louis, W. C.; Mahn, K. B. M.; Marsh, W.; Mauger, C.; McGary, V. T.; McGregor, G.; Metcalf, W.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Mousseau, J.; Nelson, R. H.; Nienaber, P.; Nowak, J. A.; Osmanov, B.; Ouedraogo, S.; Patterson, R. B.; Pavlovic, Z.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Schirato, R.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smith, D.; Soderberg, M.; Sorel, M.; Spentzouris, P.; Spitz, J.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; van de Water, R. G.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Zeller, G. P.; Zimmerman, E. D.

    2009-08-01

    The MiniBooNE Collaboration reports a search for νμ and ν¯μ disappearance in the Δm2 region of 0.5-40eV2. These measurements are important for constraining models with extra types of neutrinos, extra dimensions, and CPT violation. Fits to the shape of the νμ and ν¯μ energy spectra reveal no evidence for disappearance at the 90% confidence level (C.L.) in either mode. The test of ν¯μ disappearance probes a region below Δm2=40eV2 never explored before.

  6. The potential application of hairless guinea pigs as a replacement for the Yucatan mini-pig in animal studies

    NASA Astrophysics Data System (ADS)

    Jindra, Nichole M.; Imholte, Michelle L.

    2008-02-01

    The Yucatan mini-pig (Sus scrofa) is one of the most widely used animal models for skin damage studies because it shares many of the same physical properties as human skin. While the Yucatan is ideal for laser exposure studies using a large spot size, its size and cost are excessive for projects using smaller beams. This experiment performed histological analysis of skin biopsies from pigmented Hairless Guinea Pigs (Cavia porcellus) for epidermal thickness and melanin concentration. That data was then compared to similar information on the Yucatan.

  7. Psychometric Properties of the Mini-Social Phobia Inventory

    PubMed Central

    Seeley-Wait, Elizabeth; Rapee, Ronald M.

    2009-01-01

    Objective: Although a potentially useful measure, to date, there has been only one published test of the psychometric properties of the Mini-Social Phobia Inventory (Mini-SPIN). Therefore, the psychometric properties of the Mini-SPIN, a brief 3-item screen for social anxiety disorder, were examined. Method: Participants were 186 patients diagnosed with social anxiety disorder (DSM-IV criteria) attending a specialized anxiety disorders clinic for treatment, and 56 nonclinical participants were recruited to serve as comparisons. Participants were diagnosed using the Anxiety Disorders Interview Schedule for DSM-IV, and they also completed the Mini-SPIN, the Social Interaction Anxiety Scale (SIAS), and the Social Phobia Scale (SPS). Construct validity for the Mini-SPIN was assessed by its correlations with the SIAS and the SPS. Reliability, internal consistency, discriminant validity, and sensitivity to change were also examined, and receiver operating characteristic curve analysis was conducted to determine guidelines regarding cutoff scores for the Mini-SPIN. The study was conducted between April 1999 and December 2001. Results: Supporting findings from a previous study, strong support was found for the Mini-SPIN's ability to discriminate individuals with social anxiety disorder from those without the disorder. Receiver operating characteristic analysis revealed that using a cutoff score of 6 or greater (P < .001), the Mini-SPIN demonstrates excellent sensitivity, specificity, and positive and negative predictive values. Conclusions: Findings suggest that the Mini-SPIN is a reliable and valid instrument for screening social anxiety disorder in adults. Importantly, the use of the Mini-SPIN in primary care may be one way to address the underrecognition of social anxiety disorder in such settings. Due to the ease and brevity of the measure, it also shows potential for use in epidemiology. Given that this study has revealed the ability of the Mini-SPIN to reflect treatment change, the Mini-SPIN may also be considered for use in treatment outcome studies that specifically require minimal assessment. PMID:19956461

  8. αA-Crystallin–Derived Mini-Chaperone Modulates Stability and Function of Cataract Causing αAG98R-Crystallin

    PubMed Central

    Raju, Murugesan; Santhoshkumar, Puttur; Sharma, K. Krishna

    2012-01-01

    Background A substitution mutation in human αA-crystallin (αAG98R) is associated with autosomal dominant cataract. The recombinant mutant αAG98R protein exhibits altered structure, substrate-dependent chaperone activity, impaired oligomer stability and aggregation on prolonged incubation at 37°C. Our previous studies have shown that αA-crystallin–derived mini-chaperone (DFVIFLDVKHFSPEDLTVK) functions like a molecular chaperone by suppressing the aggregation of denaturing proteins. The present study was undertaken to determine the effect of αA-crystallin–derived mini-chaperone on the stability and chaperone activity of αAG98R-crystallin. Methodology/Principal Findings Recombinant αAG98R was incubated in presence and absence of mini-chaperone and analyzed by chromatographic and spectrometric methods. Transmission electron microscope was used to examine the effect of mini-chaperone on the aggregation propensity of mutant protein. Mini-chaperone containing photoactive benzoylphenylalanine was used to confirm the interaction of mini-chaperone with αAG98R. The rescuing of chaperone activity in mutantα-crystallin (αAG98R) by mini-chaperone was confirmed by chaperone assays. We found that the addition of the mini-chaperone during incubation of αAG98R protected the mutant crystallin from forming larger aggregates that precipitate with time. The mini-chaperone-stabilized αAG98R displayed chaperone activity comparable to that of wild-type αA-crystallin. The complexes formed between mini-αA–αAG98R complex and ADH were more stable than the complexes formed between αAG98R and ADH. Western-blotting and mass spectrometry confirmed the binding of mini-chaperone to mutant crystallin. Conclusion/Significance These results demonstrate that mini-chaperone stabilizes the mutant αA-crystallin and modulates the chaperone activity of αAG98R. These findings aid in our understanding of how to design peptide chaperones that can be used to stabilize mutant αA-crystallins and preserve the chaperone function. PMID:22970163

  9. Evaluation of fracture torque resistance of orthodontic mini-implants.

    PubMed

    Dalla Rosa, Fernando; Burmann, Paola Fp; Ruschel, Henrique C; Vargas, Ivana A; Kramer, Paulo F

    2016-12-01

    This study sought to assess the fracture torque resistance of mini-implants used for orthodontic anchorage. Five commercially available brands of mini-implants were used (SIN®, CONEXÃO®, NEODENT®, MORELLI®, andFORESTADENT®). Ten mini-implants of each diameter of each brand were tested, for a total 100 specimens. The mini-implants were subject to a static torsion test as described in ASTMstandard F543. Analysis of variance (ANOVA) with the Tukey multiple comparisons procedure was used to assess results. Overall, mean fracture strength ranged from 15.7 to 70.4 N·cm. Mini-implants with larger diameter exhibited higher peak torque values at fracture and higher yield strength, regardless of brand. In addition, significant differences across brands were observed when implants were stratified by diameter. In conclusion, larger mini-implant diameter is associated with increased fracture torque resistance. Additional information on peak torque values at fracture of different commercial brands of mini-implants may increase the success rate of this orthodontic anchorage modality. Sociedad Argentina de Investigación Odontológica.

  10. Increased intracranial pressure in mini-pigs exposed to simulated solar particle event radiation

    NASA Astrophysics Data System (ADS)

    Sanzari, Jenine K.; Muehlmatt, Amy; Savage, Alexandria; Lin, Liyong; Kennedy, Ann R.

    2014-02-01

    Changes in intracranial pressure (ICP) during space flight have stimulated an area of research in space medicine. It is widely speculated that elevations in ICP contribute to structural and functional ocular changes, including deterioration in vision, which is also observed during space flight. The aim of this study was to investigate changes in opening pressure (OP) occurring as a result of ionizing radiation exposure (at doses and dose-rates relevant to solar particle event radiation). We used a large animal model, the Yucatan mini-pig, and were able to obtain measurements over a 90 day period. This is the first investigation to show long term recordings of ICP in a large animal model without an invasive craniotomy procedure. Further, this is the first investigation reporting increased ICP after radiation exposure.

  11. Spatiotemporal monitoring of soil water content profiles in an irrigated field using probabilistic inversion of time-lapse EMI data

    NASA Astrophysics Data System (ADS)

    Moghadas, Davood; Jadoon, Khan Zaib; McCabe, Matthew F.

    2017-12-01

    Monitoring spatiotemporal variations of soil water content (θ) is important across a range of research fields, including agricultural engineering, hydrology, meteorology and climatology. Low frequency electromagnetic induction (EMI) systems have proven to be useful tools in mapping soil apparent electrical conductivity (σa) and soil moisture. However, obtaining depth profile water content is an area that has not been fully explored using EMI. To examine this, we performed time-lapse EMI measurements using a CMD mini-Explorer sensor along a 10 m transect of a maize field over a 6 day period. Reference data were measured at the end of the profile via an excavated pit using 5TE capacitance sensors. In order to derive a time-lapse, depth-specific subsurface image of electrical conductivity (σ), we applied a probabilistic sampling approach, DREAM(ZS) , on the measured EMI data. The inversely estimated σ values were subsequently converted to θ using the Rhoades et al. (1976) petrophysical relationship. The uncertainties in measured σa, as well as inaccuracies in the inverted data, introduced some discrepancies between estimated σ and reference values in time and space. Moreover, the disparity between the measurement footprints of the 5TE and CMD Mini-Explorer sensors also led to differences. The obtained θ permitted an accurate monitoring of the spatiotemporal distribution and variation of soil water content due to root water uptake and evaporation. The proposed EMI measurement and modeling technique also allowed for detecting temporal root zone soil moisture variations. The time-lapse θ monitoring approach developed using DREAM(ZS) thus appears to be a useful technique to understand spatiotemporal patterns of soil water content and provide insights into linked soil moisture vegetation processes and the dynamics of soil moisture/infiltration processes.

  12. Black Carbon Measurement Intercomparison during the 2017 Black Carbon Shootout

    NASA Astrophysics Data System (ADS)

    Shingler, T.; Moore, R.; Winstead, E.; Robinson, C. E.; Shook, M.; Crosbie, E.; Ziemba, L. D.; Thornhill, K. L., II; Sorooshian, A.; Anderson, B. E.

    2017-12-01

    The NASA Langley Aerosol Research Group (LARGE) provides multiple black carbon (BC) based aerosol particle measurements and engine emission factors for airborne and ground-based field campaigns and laboratory studies. These datasets are made available to the general public where accuracy is key to enable further use in environmental assessments, models, and validation studies. Studies are needed to establish the accuracy and precision of BC measurements of particles with varying physical properties using a variety of detection techniques. Work is also needed to develop calibration and correction schemes for new sensors and to link these measurements to heritage instruments on which our understanding of BC emissions and characteristics has been established. A BC measurement intercomparison was performed at Langley Research Center using particles generated from a mini-CAST (Jing) diffusion flame soot generator. The particles were passed to instruments measuring optical absorption, extinction, scattering and black carbon mass. Filter based measurements of optical absorption were performed using a PSAP (Radiance Research) and a TAP (BMI). Absorption was also measured using two photoacoustic based instruments: the MSS-plus (AVL) and PASS-3 (DMT). Measurements of aerosol extinction were performed using three CAPS PM-ex (Aerodyne Research) instruments at multiple wavelengths. Two Artium LII-300 units (standard and high-sensitivity) were used to measure black carbon mass via laser incandescence. Black carbon measurements were correlated to mass collected concurrently on a filter and analyzed by OC/EC analysis (Sunset Labs). Black carbon quantification measurements are analyzed between instruments to assess agreement between platforms using manufacturer's calibration settings as well as after calibrations performed to a single standard soot source (mini-CAST). Sampling was also performed from behind a Falcon aircraft at multiple thrust settings and downwind of runway at an international airport with commercial takeoffs and landings.

  13. Reliability and validity of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    PubMed

    Sheehan, David V; Sheehan, Kathy H; Shytle, R Douglas; Janavs, Juris; Bannon, Yvonne; Rogers, Jamison E; Milo, Karen M; Stock, Saundra L; Wilkinson, Berney

    2010-03-01

    To investigate the concurrent validity and reliability of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID), a short structured diagnostic interview for DSM-IV and ICD-10 psychiatric disorders in children and adolescents. Participants were 226 children and adolescents (190 outpatients and 36 controls) aged 6 to 17 years. To assess the concurrent validity of the MINI-KID, participants were administered the MINI-KID and the Schedule for Affective Disorders and Schizophrenia for School Aged Children-Present and Lifetime Version (K-SADS-PL) by blinded interviewers in a counterbalanced order on the same day. Participants also completed a self-rated measure of disability. In addition, interrater (n = 57) and test-retest (n = 83) reliability data (retest interval, 1-5 days) were collected, and agreement between the parent version of the MINI-KID and the standard MINI-KID (n = 140) was assessed. Data were collected between March 2004 and January 2008. Substantial to excellent MINI-KID to K-SADS-PL concordance was found for syndromal diagnoses of any mood disorder, any anxiety disorder, any substance use disorder, any ADHD or behavioral disorder, and any eating disorder (area under curve [AUC] = 0.81-0.96, kappa = 0.56-0.87). Results were more variable for psychotic disorder (AUC = 0.94, kappa = 0.41). Sensitivity was substantial (0.61-1.00) for 15/20 individual DSM-IV disorders. Specificity was excellent (0.81-1.00) for 18 disorders and substantial (> 0.73) for the remaining 2. The MINI-KID identified a median of 3 disorders per subject compared to 2 on the K-SADS-PL and took two-thirds less time to administer (34 vs 103 minutes). Interrater and test-retest kappas were substantial to almost perfect (0.64-1.00) for all individual MINI-KID disorders except dysthymia. Concordance of the parent version (MINI-KID-P) with the standard MINI-KID was good. The MINI-KID generates reliable and valid psychiatric diagnoses for children and adolescents and does so in a third of the time as the K-SADS-PL. (c) 2010 Physicians Postgraduate Press, Inc.

  14. Use of mini-refuges by female northern pintails wintering in southwestern Louisiana

    USGS Publications Warehouse

    Cox, Robert R.; Afton, Alan D.

    1998-01-01

    The Gulf Coast Joint Venture of the North American Waterfowl Management Plan began contracting private agricultural lands (hereafter mini-refuges) in 1988 to expand existing sanctuaries for northern pintails (Anas acuta) in southwestern Louisiana. Previous research suggested that mini-refuges may prove more attractive to pintails than permanent, open-water pools (pools) on refuges because mini-refuges provide sanctuary and food during the day, whereas pools generally provide only sanctuary (Rave and Cordes 1993). We used radiotelemetry to compare diel use of mini-refuges and pools (Lacassine Pool and Amoco Pool) by female pintails in southwestern Louisiana during winters of 1991-1992 and 1992-1993. We examined variation in use of these areas in relation to female age (immature or adult), time period (prehunting season, first hunting season, time between split hunting seasons, second hunting season, and posthunting season), and winter (1991-1992 and 1992-1993). Diurnal use of min-refuges and pools differed among time periods, but differences were not consistent between winters. Mini-refuges accounted for <2% of diurnal use by pintails in 7 of 10 time-period and winter comparisons. Diurnal use of mini-refuges was lower than that of Lacassine Pool in 8 of 10 time-period and winter comparisons. Diurnal use of mini-refuges was lower than tha of Amoco pool during first hunting season in 1992-1993, but use of these areas did not differ within other time periods and winters. Nocturnal use of mini-refuges and pools did not differ in relation to female age, time period, winter, or individual bird. Nocturnal use of mini-refuges did not differ from that of Lacassine Pool. In contrast to predictions and findings by Rave and Cordes (1993), we found that: (1) female pintails did not use mini-refuges more than pools, and (2) female pintails used mini-refuges at night. We believe that use of mini-refuges by pintails could be increased if mini-refuges were (1) located in areas of traditionally high pintail use, (2) increased in size, (3) flooded immediately prior to hunting season, and (4) cleared of dense vegetation by rolling, disking, or burning.

  15. Enhanced heat sink with geometry induced wall-jet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hossain, Md. Mahamudul, E-mail: sohel0991@gmail.com; Tikadar, Amitav; Bari, Fazlul

    Mini-channels embedded in solid matrix have already proven to be a very efficient way of electronic cooling. Traditional mini-channel heat sinks consist of single layer of parallel channels. Although mini-channel heat sink can achieve very high heat flux, its pumping requirement for circulating liquid through the channel increase very sharply as the flow velocity increases. The pumping requirements of the heat sink can be reduced by increasing its performance. In this paper a novel approach to increase the thermal performance of the mini-channel heat sink is proposed through geometry induced wall jet which is a passive technique. Geometric irregularities alongmore » the channel length causes abrupt pressure change between the channels which causes cross flow through the interconnections thus one channel faces suction and other channel jet action. This suction and jet action disrupts boundary layer causing enhanced heat transfer performance. A CFD model has been developed using commercially available software package FLUENT to evaluate the technique. A parametric study of the velocities and the effect of the position of the wall-jets have been performed. Significant reduction in thermal resistance has been observed for wall-jets, it is also observed that this reduction in thermal resistance is dependent on the position and shape of the wall jet.« less

  16. Dark Matter Search in a Proton Beam Dump with MiniBooNE

    DOE PAGES

    Aguilar-Arevalo, A. A.; Backfish, M.; Bashyal, A.; ...

    2017-05-31

    The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86 × 10 20 protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the darkmore » matter cross section parameter, Y = ε 2α D(m χ/m V) 4≲10 –8, for α D = 0.5 and for dark matter masses of 0.01 < m χ < 0.3 GeV in a vector portal model of dark matter. This is the best limit from a dedicated proton beam dump search in this mass and coupling range and extends below the mass range of direct dark matter searches. Here, these results demonstrate a novel and powerful approach to dark matter searches with beam dump experiments.« less

  17. The Mini-OAKHQOL for knee and hip osteoarthritis quality of life was obtained following recent shortening guidelines.

    PubMed

    Guillemin, Francis; Rat, Anne-Christine; Goetz, Christophe; Spitz, Elisabeth; Pouchot, Jacques; Coste, Joël

    2016-01-01

    To develop a short form of the knee and hip osteoarthritis quality of life questionnaire, the Mini-OAKHQOL, preserving the conceptual model and, as far as possible, the content and the psychometric properties of the original instrument. A two-step shortening procedure was used: (1) a consensus Delphi method, with a panel of patients and another of professionals independently asked to select items and (2) a nominal group, where patients, professionals, and methodologists reached consensus on the final selection of items, using information from the panels and from modern measurement and classical test theory analyses. The psychometric properties of the Mini-OAKHQOL were assessed in an independent population-based sample of 581 subjects with knee or hip osteoarthritis. The two-step shortening procedure resulted in a 20-item questionnaire. Confirmatory factor analysis showed preservation of the original five-dimensional structure. Rasch analyses showed the unidimensionality and invariance by sex, age, and joint of the main dimensions. Convergent validity, reproducibility, and internal consistency were similar to or better than those of the original OAKHQOL. The 20-item Mini-OAKHQOL has good psychometric properties and can be used for the measurement of quality of life in subjects with osteoarthritis of the lower limbs. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Dark Matter Search in a Proton Beam Dump with MiniBooNE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilar-Arevalo, A. A.; Backfish, M.; Bashyal, A.

    The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86 × 10 20 protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the darkmore » matter cross section parameter, Y = ε 2α D(m χ/m V) 4≲10 –8, for α D = 0.5 and for dark matter masses of 0.01 < m χ < 0.3 GeV in a vector portal model of dark matter. This is the best limit from a dedicated proton beam dump search in this mass and coupling range and extends below the mass range of direct dark matter searches. Here, these results demonstrate a novel and powerful approach to dark matter searches with beam dump experiments.« less

  19. The development of mini project interactive media on junior statistical materials (developmental research in junior high school)

    NASA Astrophysics Data System (ADS)

    Fauziah, D.; Mardiyana; Saputro, D. R. S.

    2018-05-01

    Assessment is an integral part in the learning process. The process and the result should be in line, regarding to measure the ability of learners. Authentic assessment refers to a form of assessment that measures the competence of attitudes, knowledge, and skills. In fact, many teachers including mathematics teachers who have implemented curriculum based teaching 2013 feel confuse and difficult in mastering the use of authentic assessment instruments. Therefore, it is necessary to design an authentic assessment instrument with an interactive mini media project where teacher can adopt it in the assessment. The type of this research is developmental research. The developmental research refers to the 4D models development, which consist of four stages: define, design, develop and disseminate. The research purpose is to create a valid mini project interactive media on statistical materials in junior high school. The retrieved valid instrument based on expert judgment are 3,1 for eligibility constructions aspect, and 3,2 for eligibility presentation aspect, 3,25 for eligibility contents aspect, and 2,9 for eligibility didactic aspect. The research results obtained interactive mini media projects on statistical materials using Adobe Flash so it can help teachers and students in achieving learning objectives.

  20. Vaporization inside a mini microfin tube: experimental results and modeling

    NASA Astrophysics Data System (ADS)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  1. Comparison of the Fullerton Advanced Balance Scale, Mini-BESTest, and Berg Balance Scale to Predict Falls in Parkinson Disease.

    PubMed

    Schlenstedt, Christian; Brombacher, Stephanie; Hartwigsen, Gesa; Weisser, Burkhard; Möller, Bettina; Deuschl, Günther

    2016-04-01

    The correct identification of patients with Parkinson disease (PD) at risk for falling is important to initiate appropriate treatment early. This study compared the Fullerton Advanced Balance (FAB) scale with the Mini-Balance Evaluation Systems Test (Mini-BESTest) and Berg Balance Scale (BBS) to identify individuals with PD at risk for falls and to analyze which of the items of the scales best predict future falls. This was a prospective study to assess predictive criterion-related validity. The study was conducted at a university hospital in an urban community. Eighty-five patients with idiopathic PD (Hoehn and Yahr stages: 1-4) participated in the study. Measures were number of falls (assessed prospectively over 6 months), FAB scale, Mini-BESTest, BBS, and Unified Parkinson's Disease Rating Scale. The FAB scale, Mini-BESTest, and BBS showed similar accuracy to predict future falls, with values for area under the curve (AUC) of the receiver operating characteristic (ROC) curve of 0.68, 0.65, and 0.69, respectively. A model combining the items "tandem stance," "rise to toes," "one-leg stance," "compensatory stepping backward," "turning," and "placing alternate foot on stool" had an AUC of 0.84 of the ROC curve. There was a dropout rate of 19/85 participants. The FAB scale, Mini-BESTest, and BBS provide moderate capacity to predict "fallers" (people with one or more falls) from "nonfallers." Only some items of the 3 scales contribute to the detection of future falls. Clinicians should particularly focus on the item "tandem stance" along with the items "one-leg stance," "rise to toes," "compensatory stepping backward," "turning 360°," and "placing foot on stool" when analyzing postural control deficits related to fall risk. Future research should analyze whether balance training including the aforementioned items is effective in reducing fall risk. © 2016 American Physical Therapy Association.

  2. Photochemistry in terrestrial exoplanet atmospheres. III. Photochemistry and thermochemistry in thick atmospheres on super Earths and mini Neptunes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Renyu; Seager, Sara, E-mail: hury@caltech.edu

    Some super Earths and mini Neptunes will likely have thick atmospheres that are not H{sub 2}-dominated. We have developed a photochemistry-thermochemistry kinetic-transport model for exploring the compositions of thick atmospheres on super Earths and mini Neptunes, applicable for both H{sub 2}-dominated atmospheres and non-H{sub 2}-dominated atmospheres. Using this model to study thick atmospheres for wide ranges of temperatures and elemental abundances, we classify them into hydrogen-rich atmospheres, water-rich atmospheres, oxygen-rich atmospheres, and hydrocarbon-rich atmospheres. We find that carbon has to be in the form of CO{sub 2} rather than CH{sub 4} or CO in a H{sub 2}-depleted water-dominated thick atmospheremore » and that the preferred loss of light elements from an oxygen-poor carbon-rich atmosphere leads to the formation of unsaturated hydrocarbons (C{sub 2}H{sub 2} and C{sub 2}H{sub 4}). We apply our self-consistent atmosphere models to compute spectra and diagnostic features for known transiting low-mass exoplanets GJ 1214 b, HD 97658 b, and 55 Cnc e. For GJ 1214 b, we find that (1) C{sub 2}H{sub 2} features at 1.0 and 1.5 μm in transmission and C{sub 2}H{sub 2} and C{sub 2}H{sub 4} features at 9-14 μm in thermal emission are diagnostic for hydrocarbon-rich atmospheres; (2) a detection of water-vapor features and a confirmation of the nonexistence of methane features would provide sufficient evidence for a water-dominated atmosphere. In general, our simulations show that chemical stability has to be taken into account when interpreting the spectrum of a super Earth/mini Neptune. Water-dominated atmospheres only exist for carbon to oxygen ratios much lower than the solar ratio, suggesting that this kind of atmospheres could be rare.« less

  3. Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography

    PubMed Central

    Abbassy, Mona A.; Sabban, Hanady M.; Hassan, Ali H.; Zawawi, Khalid H.

    2015-01-01

    Objectives: To evaluate the accuracy of using routine 2-dimensional (2D) radiographs (panoramic and periapical) when evaluating the position of orthodontic temporary anchorage devices (mini-implants) in the maxilla, and to compare the results to 3-dimensional cone-beam computed tomography (CBCT). Methods: This cross-sectional study was conducted at King Abdulaziz University, Faculty of Dentistry, Jeddah, Kingdom of Saudi Arabia from February 2014 to January 2015. Panoramic and periapical radiographs were used to examine the position of mini-implants in relation to the adjacent roots. Rating of mini-implants position was performed by 82 dentists from different specialties, using 2 D images according to the following criteria: 1) away from the root; 2) mini-implant tip appears touching the lamina dura; and 3) mini-implant overlays the lamina dura. The results were compared with CBCT findings. Results: There was no difference between dentists from different specialties when rating the position of the mini-implants (Cronbach’s alpha=0.956). The accuracy of the periapical images was 45.1%, while the panoramic images 33.6%. However, both panoramic and periapical radiographs were significantly inaccurate when assessing the mini-implant position when compared with the CBCT findings (p=0.0001). Conclusion: Three-dimensional CBCT technology allows better visualization of mini-implant placement. The use of CBCT when assessing the position of mini-implants is recommended. PMID:26593168

  4. A DNA mini-barcode for land plants.

    PubMed

    Little, Damon P

    2014-05-01

    Small portions of the barcode region - mini-barcodes - may be used in place of full-length barcodes to overcome DNA degradation for samples with poor DNA preservation. 591,491,286 rbcL mini-barcode primer combinations were electronically evaluated for PCR universality, and two novel highly universal sets of priming sites were identified. Novel and published rbcL mini-barcode primers were evaluated for PCR amplification [determined with a validated electronic simulation (n = 2765) and empirically (n = 188)], Sanger sequence quality [determined empirically (n = 188)], and taxonomic discrimination [determined empirically (n = 30,472)]. PCR amplification for all mini-barcodes, as estimated by validated electronic simulation, was successful for 90.2-99.8% of species. Overall Sanger sequence quality for mini-barcodes was very low - the best mini-barcode tested produced sequences of adequate quality (B20 ≥ 0.5) for 74.5% of samples. The majority of mini-barcodes provide correct identifications of families in excess of 70.1% of the time. Discriminatory power noticeably decreased at lower taxonomic levels. At the species level, the discriminatory power of the best mini-barcode was less than 38.2%. For samples believed to contain DNA from only one species, an investigator should attempt to sequence, in decreasing order of utility and probability of success, mini-barcodes F (rbcL1/rbcLB), D (F52/R193) and K (F517/R604). For samples believed to contain DNA from more than one species, an investigator should amplify and sequence mini-barcode D (F52/R193). © 2013 John Wiley & Sons Ltd.

  5. The use of cochlear's SCAN and wireless microphones to improve speech understanding in noise with the Nucleus6® CP900 processor.

    PubMed

    De Ceulaer, Geert; Pascoal, David; Vanpoucke, Filiep; Govaerts, Paul J

    2017-11-01

    The newest Nucleus CI processor, the CP900, has two new options to improve speech-in-noise perception: (1) use of an adaptive directional microphone (SCAN mode) and (2) wireless connection to MiniMic1 and MiniMic2 wireless remote microphones. An analysis was made of the absolute and relative benefits of these technologies in a real-world mimicking test situation. Speech perception was tested using an adaptive speech-in-noise test (sentences-in-babble noise). In session A, SRTs were measured in three conditions: (1) Clinical Map, (2) SCAN and (3) MiniMic1. Each was assessed for three distances between speakers and CI recipient: 1 m, 2 m and 3 m. In session B, the benefit of the use of MiniMic2 was compared to benefit of MiniMic1 at 3 m. A group of 13 adult CP900 recipients participated. SCAN and MiniMic1 improved performance compared to the standard microphone with a median improvement in SRT of 2.7-3.9 dB for SCAN at 1 m and 3 m, respectively, and 4.7-10.9 dB for the MiniMic1. MiniMic1 improvements were significant. MiniMic2 showed an improvement in SRT of 22.2 dB compared to 10.0 dB for MiniMic1 (3 m). Digital wireless transmission systems (i.e. MiniMic) offer a statistically and clinically significant improvement in speech perception in challenging, realistic listening conditions.

  6. Childhood obesity and insulin resistance in a Yucatan mini-piglet model: putative roles of IGF-1 and muscle PPARs in adipose tissue activity and development.

    PubMed

    Sébert, S P; Lecannu, G; Kozlowski, F; Siliart, B; Bard, J M; Krempf, M; Champ, M M-J

    2005-03-01

    To explore metabolic and cellular modifications induced during childhood obesity, in a novel animal model of obese mini-piglets. A total of 10 four-month old Yucatan mini-pigs were followed from prepuberty to adulthood. Animals were divided into two groups. The first one had been overfed (OF) a western-type diet and the second one had been normally fed a control recommended human-type diet (NF). Plasma insulin-like growth factor 1 (IGF-1), insulin, leptin, nonesterified fatty acids, triglycerides (TGs) and glucose were determined at sexual maturity and at young adulthood. Quantitative gene expressions of peroxysome-proliferator-activated receptors (PPARs), glucose transporter 4, insulin receptor, IGF-1, leptin and interleukin-6 (IL-6) in skeletal muscle, adipose tissue and liver were also measured at both stages. Adult insulin sensitivity was measured via euglycaemic-hyperinsulinaemic clamps. Increased body weight in adult OF pigs was associated with increased body size and low insulin sensitivity. Sexually mature OF pigs had higher IGF-1 plasma concentrations than their lean littermates (P < 0.05). In the OF group, TGs and glucose were both decreased (P < 0.05). Muscle PPARgamma and alpha in OF pubescent pigs as compared to NF pigs were 11 times higher and 20 times lower, respectively (P < 0.01). Obesity and insulin resistance induced by overfeeding mini-pigs during development and puberty were not associated with the cluster of metabolic modifications frequently observed in their adult littermates. Increased IGF-1 concentrations and modifications of skeletal muscle PPAR (alpha and gamma) expressions may help the young obese pig to partially regulate its glycaemia and triglyceridaemia through an increase of fat mass, which maintains its high insulin sensitivity.

  7. Major depressive disorder and suicide risk among adult outpatients at several general hospitals in a Chinese Han population.

    PubMed

    Li, Haiyan; Luo, Xinni; Ke, Xiaoyin; Dai, Qing; Zheng, Wei; Zhang, Chanjuan; Cassidy, Ryan M; Soares, Jair C; Zhang, XiangYang; Ning, Yuping

    2017-01-01

    Somatic complaints are often the presenting symptoms of major depressive disorder (MDD) in the outpatient context, because this may go unrecognized. It is well understood that MDD carries an increased risk of suicide. This study aimed to identify the risk factors and association with both MDD and suicidality among Han Chinese outpatients. A multicenter study was carried out in 5189 outpatient adults (≥18 years old) in four general hospitals in Guangzhou, China. The 1392 patients who had the Patient Health Questionnaire-9 (PHQ-9) score ≥ 5, indicating depressive symptoms were offered an interview with a psychiatrist by the Mini International Neuropsychiatric Interview (MINI); 819 patients consented and completed the MINI interview. MINI module B was used to assess suicidality. Stepwise binary logistic models were used to estimate the relationship between a significant risk factor and suicide or MDD. According to with or without MDD, the secondary analysis was performed using the logistic regression model for the risk of suicidility. The current prevalence of MDD and the one month prevalence of suicidality were 3.7% and 2.3% respectively. The odds ratio of suicidality in women was more than twice that in men (OR = 2.62; 95% CI 1.45-4.76). Other risk factors which were significantly associated with suicidality were: living alone, higher education, self-reported depression, getting psychiatric diagnoses (MDD, anxiety disorders, and bipolar disorders). Significant risk factors for MDD were also noticed, such as comorbid anxiety disorders, self-reported anxiety, insomnia, suicidal ideation. It's a cross-sectional study in outpatient clinics using self-report questionnaires. This study provides valuable data about the risk factors and association of MDD and suicide risk in adult outpatients in Han Chinese. Those factors allow better the employment of preventative measures.

  8. ISS Mini AERCam Radio Frequency (RF) Coverage Analysis Using iCAT Development Tool

    NASA Technical Reports Server (NTRS)

    Bolen, Steve; Vazquez, Luis; Sham, Catherine; Fredrickson, Steven; Fink, Patrick; Cox, Jan; Phan, Chau; Panneton, Robert

    2003-01-01

    The long-term goals of the National Aeronautics and Space Administration's (NASA's) Human Exploration and Development of Space (HEDS) enterprise may require the development of autonomous free-flier (FF) robotic devices to operate within the vicinity of low-Earth orbiting spacecraft to supplement human extravehicular activities (EVAs) in space. Future missions could require external visual inspection of the spacecraft that would be difficult, or dangerous, for humans to perform. Under some circumstance, it may be necessary to employ an un-tethered communications link between the FF and the users. The interactive coverage analysis tool (ICAT) is a software tool that has been developed to perform critical analysis of the communications link performance for a FF operating in the vicinity of the International Space Station (ISS) external environment. The tool allows users to interactively change multiple parameters of the communications link parameters to efficiently perform systems engineering trades on network performance. These trades can be directly translated into design and requirements specifications. This tool significantly reduces the development time in determining a communications network topology by allowing multiple parameters to be changed, and the results of link coverage to be statistically characterized and plotted interactively.

  9. Active oligonucleotides incorporating alkylating an agent as potential sequence- and base selective modifier of gene expression.

    PubMed

    Sasaki, S

    2001-04-01

    A number of cross-linking (alkylating) agents have been developed and incorporated into the oligonulceotides for sequence selective control of gene expression. Recently, potential application of such active oligonucleotides has been expanding from use for improvement of inhibition efficiency to new biotechnology that may enable chemical alteration of genetic information. These interests in active oligonucleotides have encouraged the generation of new cross-linking agents that exhibit high efficiency for application of either in vitro or in vivo. This mini review summarizes structures of alkylating agents, in particular, a new basic skeleton for cross-linking, a 2'-deoxyribose derivative of 2-amino-6-vinylpurine that has been recently developed by the author's group. The 2-amino-6-vinylpurine has been shown to form a complex with cytidine under acidic conditions, and brings the vinyl and the amino reactive groups into proximity to achieve efficient alkylation. A new strategy was designed so that the reactivity of 2-amino-6-vinylpurine can be induced from the corresponding phenylsulfoxide derivative within a duplex with the complementary strand. The validity of the new strategy has been proven by achievement of cytidine-selective cross-linking with remarkably efficiency.

  10. Reading Mini-Lessons: An Instructional Practice for Meaning Centered Reading Programs.

    ERIC Educational Resources Information Center

    Barrentine, Shelby; And Others

    1995-01-01

    Mini-lessons (brief, informative explanations that demonstrate what readers do) are a key instructional practice in meaning centered reading programs. The content of the mini-lessons is determined by the needs of learners. In procedural mini-lessons, teachers explain the steps for successfully completing a task or performing a reading-related…

  11. Using the Planetary Science Institute’s Meteorite Mini-Kits to Address the Nature of Science

    NASA Astrophysics Data System (ADS)

    Lebofsky, Larry A.; Cañizo, Thea L.; Buxner, Sanlyn

    2014-11-01

    Hands-on learning allows students to understand science concepts by directly observing and experiencing the topics they are studying. The Planetary Science Institute (PSI) has created instructional rock kits that have been introduced to elementary and middle school teachers in Tucson, in our professional development workshops. PSI provides teachers with supporting material and training so that they can use the kits as tools for students’ hands-on learning. Use of these kits provides an important experience with natural materials that is essential to instruction in Earth and Space Science. With a stronger knowledge of science content and of how science is actually conducted, the workshops and kits have instilled greater confidence in teachers’ ability to teach science content. The Next Generation Science Standards (NGSS) Performance Expectations includes: “What makes up our solar system?” NGSS emphasizes the Crosscutting Concepts—Patterns Scale, Portion, and Quantity; and Systems and System Models. NGSS also states that the Nature of Science (NOS) should be an “essential part” of science education. NOS topics include understanding that scientific investigations use a variety of methods, that scientific knowledge is based on empirical evidence, that scientific explanations are open to revision in light of new evidence, and an understanding of the nature of scientific models.Addressing a need expressed by teachers for borrowing kits less expensive than our $2000 option, we created a Meteorite Mini-Kit. Each Mini-Kit contains eight rocks: an iron-bearing chondrite, a sliced chondrite (showing iron and chondrules), a tektite, a common Tucson rock, a river-polished rock, pumice, a small iron, and a rounded obsidian rock (false tektite). Also included in the Mini-Kits are magnets and a magnifier. The kits cost $40 to $50, depending on the sizes of the chondrites. A teacher can check out a classroom set of these which contains either 10 or 20 Mini-Kits. Each kit includes a description of the rocks as well as suggestions for using them in the classroom. Our presentation will highlight their use in various venues.

  12. Spacecraft dynamics characterization and control system failure detection. Volume 3: Control system failure monitoring

    NASA Technical Reports Server (NTRS)

    Vanschalkwyk, Christiaan M.

    1992-01-01

    We discuss the application of Generalized Parity Relations to two experimental flexible space structures, the NASA Langley Mini-Mast and Marshall Space Flight Center ACES mast. We concentrate on the generation of residuals and make no attempt to implement the Decision Function. It should be clear from the examples that are presented whether it would be possible to detect the failure of a specific component. We derive the equations from Generalized Parity Relations. Two special cases are treated: namely, Single Sensor Parity Relations (SSPR) and Double Sensor Parity Relations (DSPR). Generalized Parity Relations for actuators are also derived. The NASA Langley Mini-Mast and the application of SSPR and DSPR to a set of displacement sensors located at the tip of the Mini-Mast are discussed. The performance of a reduced order model that includes the first five models of the mast is compared to a set of parity relations that was identified on a set of input-output data. Both time domain and frequency domain comparisons are made. The effect of the sampling period and model order on the performance of the Residual Generators are also discussed. Failure detection experiments where the sensor set consisted of two gyros and an accelerometer are presented. The effects of model order and sampling frequency are again illustrated. The detection of actuator failures is discussed. We use Generalized Parity Relations to monitor control system component failures on the ACES mast. An overview is given of the Failure Detection Filter and experimental results are discussed. Conclusions and directions for future research are given.

  13. Reengineering a transmembrane protein to treat muscular dystrophy using exon skipping.

    PubMed

    Gao, Quan Q; Wyatt, Eugene; Goldstein, Jeff A; LoPresti, Peter; Castillo, Lisa M; Gazda, Alec; Petrossian, Natalie; Earley, Judy U; Hadhazy, Michele; Barefield, David Y; Demonbreun, Alexis R; Bönnemann, Carsten; Wolf, Matthew; McNally, Elizabeth M

    2015-11-02

    Exon skipping uses antisense oligonucleotides as a treatment for genetic diseases. The antisense oligonucleotides used for exon skipping are designed to bypass premature stop codons in the target RNA and restore reading frame disruption. Exon skipping is currently being tested in humans with dystrophin gene mutations who have Duchenne muscular dystrophy. For Duchenne muscular dystrophy, the rationale for exon skipping derived from observations in patients with naturally occurring dystrophin gene mutations that generated internally deleted but partially functional dystrophin proteins. We have now expanded the potential for exon skipping by testing whether an internal, in-frame truncation of a transmembrane protein γ-sarcoglycan is functional. We generated an internally truncated γ-sarcoglycan protein that we have termed Mini-Gamma by deleting a large portion of the extracellular domain. Mini-Gamma provided functional and pathological benefits to correct the loss of γ-sarcoglycan in a Drosophila model, in heterologous cell expression studies, and in transgenic mice lacking γ-sarcoglycan. We generated a cellular model of human muscle disease and showed that multiple exon skipping could be induced in RNA that encodes a mutant human γ-sarcoglycan. Since Mini-Gamma represents removal of 4 of the 7 coding exons in γ-sarcoglycan, this approach provides a viable strategy to treat the majority of patients with γ-sarcoglycan gene mutations.

  14. Reengineering a transmembrane protein to treat muscular dystrophy using exon skipping

    PubMed Central

    Gao, Quan Q.; Wyatt, Eugene; Goldstein, Jeff A.; LoPresti, Peter; Castillo, Lisa M.; Gazda, Alec; Petrossian, Natalie; Earley, Judy U.; Hadhazy, Michele; Barefield, David Y.; Demonbreun, Alexis R.; Bönnemann, Carsten; Wolf, Matthew; McNally, Elizabeth M.

    2015-01-01

    Exon skipping uses antisense oligonucleotides as a treatment for genetic diseases. The antisense oligonucleotides used for exon skipping are designed to bypass premature stop codons in the target RNA and restore reading frame disruption. Exon skipping is currently being tested in humans with dystrophin gene mutations who have Duchenne muscular dystrophy. For Duchenne muscular dystrophy, the rationale for exon skipping derived from observations in patients with naturally occurring dystrophin gene mutations that generated internally deleted but partially functional dystrophin proteins. We have now expanded the potential for exon skipping by testing whether an internal, in-frame truncation of a transmembrane protein γ-sarcoglycan is functional. We generated an internally truncated γ-sarcoglycan protein that we have termed Mini-Gamma by deleting a large portion of the extracellular domain. Mini-Gamma provided functional and pathological benefits to correct the loss of γ-sarcoglycan in a Drosophila model, in heterologous cell expression studies, and in transgenic mice lacking γ-sarcoglycan. We generated a cellular model of human muscle disease and showed that multiple exon skipping could be induced in RNA that encodes a mutant human γ-sarcoglycan. Since Mini-Gamma represents removal of 4 of the 7 coding exons in γ-sarcoglycan, this approach provides a viable strategy to treat the majority of patients with γ-sarcoglycan gene mutations. PMID:26457733

  15. HARP targets pion production cross section and yield measurements. Implications for MiniBooNE neutrino flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wickremasinghe, Don Athula Abeyarathna

    2015-07-01

    The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields, d 2N π± (p; θ )=dpd Ω, on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum frommore » 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target π + production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of v μ flux predictions for updated SW model is presented.« less

  16. The Mini-Balance Evaluation Systems Test (Mini-BESTest) Demonstrates Higher Accuracy in Identifying Older Adult Participants With History of Falls Than Do the BESTest, Berg Balance Scale, or Timed Up and Go Test.

    PubMed

    Yingyongyudha, Anyamanee; Saengsirisuwan, Vitoon; Panichaporn, Wanvisa; Boonsinsukh, Rumpa

    2016-01-01

    Balance deficits a significant predictor of falls in older adults. The Balance Evaluation Systems Test (BESTest) and the Mini-Balance Evaluation Systems Test (Mini-BESTest) are tools that may predict the likelihood of a fall, but their capabilities and accuracies have not been adequately addressed. Therefore, this study aimed at examining the capabilities of the BESTest and Mini-BESTest for identifying older adult with history of falls and comparing the participants with history of falls identification accuracy of the BESTest, Mini-BESTest, Berg Balance Scale (BBS), and the Timed Up and Go Test (TUG) for identifying participants with a history of falls. Two hundred healthy older adults with a mean age of 70 years were classified into participants with and without history of fall groups on the basis of their 12-month fall history. Their balance abilities were assessed using the BESTest, Mini-BESTest, BBS, and TUG. An analysis of the resulting receiver operating characteristic curves was performed to calculate the area under the curve (AUC), sensitivity, specificity, cutoff score, and posttest accuracy of each. The Mini-BESTest showed the highest AUC (0.84) compared with the BESTest (0.74), BBS (0.69), and TUG (0.35), suggesting that the Mini-BESTest had the highest accuracy in identifying older adult with history of falls. At the cutoff score of 16 (out of 28), the Mini-BESTest demonstrated a posttest accuracy of 85% with a sensitivity of 85% and specificity of 75%. The Mini-BESTest had the highest posttest accuracy, with the others having results of 76% (BESTest), 60% (BBS), and 65% (TUG). The Mini-BESTest is the most accurate tool for identifying older adult with history of falls compared with the BESTest, BBS, and TUG.

  17. Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

    PubMed

    Bortoluzzi, C; Paras, K L; Applegate, T J; Verocai, G G

    2018-04-30

    Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive correlation among the four dl (p ≤ 0.05). In the accuracy study, it was observed that the Mini-FLOTAC dl 5 and 23 were more accurate than the McMaster for 100 OPG, and the Mini-FLOTAC dl 23 had the highest accuracy for 500 OPG. The McMaster and Mini-FLOTAC dl 23 techniques were more accurate than the Mini-FLOTAC dl 5 for 5,000 OPG, and both dl of the Mini-FLOTAC were less accurate for 10,000 OPG counts than the McMaster technique. However, the overall accuracy of the Mini-FLOTAC dl 23 was higher than the McMaster and Mini-FLOTAC dl 5 techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Risk Assessment of Alzheimer's Disease using the Information Diffusion Model from Structural Magnetic Resonance Imaging.

    PubMed

    Beheshti, Iman; Olya, Hossain G T; Demirel, Hasan

    2016-04-05

    Recently, automatic risk assessment methods have been a target for the detection of Alzheimer's disease (AD) risk. This study aims to develop an automatic computer-aided AD diagnosis technique for risk assessment of AD using information diffusion theory. Information diffusion is a fuzzy mathematics logic of set-value that is used for risk assessment of natural phenomena, which attaches fuzziness (uncertainty) and incompleteness. Data were obtained from voxel-based morphometry analysis of structural magnetic resonance imaging. The information diffusion model results revealed that the risk of AD increases with a reduction of the normalized gray matter ratio (p > 0.5, normalized gray matter ratio <40%). The information diffusion model results were evaluated by calculation of the correlation of two traditional risk assessments of AD, the Mini-Mental State Examination and the Clinical Dementia Rating. The correlation results revealed that the information diffusion model findings were in line with Mini-Mental State Examination and Clinical Dementia Rating results. Application of information diffusion model contributes to the computerization of risk assessment of AD, which has a practical implication for the early detection of AD.

  19. Teacher Supervision and Evaluation: A Case Study of Administrators' and Teachers' Perceptions of Mini Observations

    ERIC Educational Resources Information Center

    Campbell, Thomas F.

    2013-01-01

    This case study will investigate teachers' and administrators' perceptions of the relationship between mini observations and teacher performance to understand what effect, if any, a system of mini observations has on teacher performance, and if mini observations influences a teacher's pedagogical practice differently than a…

  20. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    PubMed

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional "one mini-plate" or "two mini-plates" systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.

  1. Autophagy is essential for maintaining the growth of a human (mini-)organ: Evidence from scalp hair follicle organ culture

    PubMed Central

    Allavena, Giulia; Marotta, Roberto; Catelani, Tiziano; Bertolini, Marta; Paus, Ralf

    2018-01-01

    Autophagy plays a crucial role in health and disease, regulating central cellular processes such as adaptive stress responses, differentiation, tissue development, and homeostasis. However, the role of autophagy in human physiology is poorly understood, highlighting a need for a model human organ system to assess the efficacy and safety of strategies to therapeutically modulate autophagy. As a complete, cyclically remodelled (mini-)organ, the organ culture of human scalp hair follicles (HFs), which, after massive growth (anagen), spontaneously enter into an apoptosis-driven organ involution (catagen) process, may provide such a model. Here, we reveal that in anagen, hair matrix keratinocytes (MKs) of organ-cultured HFs exhibit an active autophagic flux, as documented by evaluation of endogenous lipidated Light Chain 3B (LC3B) and sequestosome 1 (SQSTM1/p62) proteins and the ultrastructural visualization of autophagosomes at all stages of the autophagy process. This autophagic flux is altered during catagen, and genetic inhibition of autophagy promotes catagen development. Conversely, an anti–hair loss product markedly enhances intrafollicular autophagy, leading to anagen prolongation. Collectively, our data reveal a novel role of autophagy in human hair growth. Moreover, we show that organ-cultured scalp HFs are an excellent preclinical research model for exploring the role of autophagy in human tissue physiology and for evaluating the efficacy and tissue toxicity of candidate autophagy-modulatory agents in a living human (mini-)organ. PMID:29590104

  2. Recent Innovations in Collagen Corneal Cross-linking; a Mini Review.

    PubMed

    Vastardis, Iraklis; Pajic-Eggspuehler, Brigitte; Nichorlis, Charis; Mueller, Jörg; Pajic, Bojan

    2017-01-01

    The introduction of corneal cross-linking (CXL) with ultraviolet-A (UVA) and Riboflavin photosensitizer (Vit B 2 ) from Seiler et al. , revolutionized the treatment of Keratoconus and other corneal ectatic diseases. Today, the commonly known epithelium off Dresden protocol is in clinical use for the last 15 years with great success and regarded by many as the golden standard. With several studies demonstrating its simplicity, efficacy and safety this revolutionary method, paved the way for new therapies and strategies in the treatment of corneal ectatic diseases and changed our understanding in corneal biomechanics. Recent scientific and technological advances enabled the creation of various modifications of the initial CXL protocol and the formation of new ones. This work highlights the recent advances of CXL, such as the role of oxygen, higher fluence and shorter irradiation times as well as the various clinical applications and updates of this method.

  3. Journal of Transportation and Statistics, Vol. 3, No. 2 : special issue on the statistical analysis and modeling of automotive emissions

    DOT National Transportation Integrated Search

    2000-09-01

    This special issue of the Journal of Transportation and Statistics is devoted to the statistical analysis and modeling of automotive emissions. It contains many of the papers presented in the mini-symposium last August and also includes one additiona...

  4. Geomagnetic field modeling by optimal recursive filtering

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Data sets selected for mini-batches and the software modifications required for processing these sets are described. Initial analysis was performed on minibatch field model recovery. Studies are being performed to examine the convergence of the solutions and the maximum expansion order the data will support in the constant and secular terms.

  5. Measurement of νμ and νe Events in an Off-Axis Horn-Focused Neutrino Beam

    NASA Astrophysics Data System (ADS)

    Adamson, P.; Aguilar-Arevalo, A. A.; Anderson, C. E.; Bazarko, A. O.; Bishai, M.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Choudhary, B. C.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Gallagher, H. R.; Garcia, F. G.; Garvey, G. T.; Green, C.; Green, J. A.; Harris, D.; Hart, T. L.; Hawker, E.; Hylen, J.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kopp, S.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Linden, S. K.; Link, J. M.; Liu, Y.; Liu, Y.; Loiacono, L.; Louis, W. C.; Marchionni, A.; Mahn, K. B. M.; Marsh, W.; McGregor, G.; Messier, M. D.; Metcalf, W.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Nelson, J. K.; Nelson, R. H.; Nguyen, V. T.; Nienaber, P.; Nowak, J. A.; Ouedraogo, S.; Patterson, R. B.; Pavlovic, Z.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Schirato, R.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smart, W.; Smith, D.; Sodeberg, M.; Sorel, M.; Spentzouris, P.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; Vahle, P.; van de Water, R.; Viren, B.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Yumiceva, F. X.; Zeller, G. P.; Zimmerman, E. D.; Zwaska, R.

    2009-05-01

    We report the first observation of off-axis neutrino interactions in the MiniBooNE detector from the NuMI beam line at Fermilab. The MiniBooNE detector is located 745 m from the NuMI production target, at 110 mrad angle (6.3°) with respect to the NuMI beam axis. Samples of charged-current quasielastic νμ and νe interactions are analyzed and found to be in agreement with expectation. This provides a direct verification of the expected pion and kaon contributions to the neutrino flux and validates the modeling of the NuMI off-axis beam.

  6. Mini-TES Observations of Comanche Carbonate and its Distribution

    NASA Astrophysics Data System (ADS)

    Ruff, S. W.; Morris, R. V.

    2010-12-01

    The discovery by the Spirit rover of outcrops rich in Mg-Fe carbonate [Morris et al., 2010] represents another manifestation of a diverse aqueous history in Gusev crater. In 2005, observations by the Mössbauer spectrometer (MB) on outcrops dubbed Comanche provided initial indication of Fe-Mg carbonate that was subsequently supported by analysis of elemental data from the Alpha Particle X-ray Spectrometer (APXS). The recognition of a carbonate component in thermal infrared spectra measured by the Miniature Thermal Emission Spectrometer (Mini-TES) was significantly delayed due to dust contamination of the instrument’s optics. With the implementation of a viable dust correction, the Comanche spectra were revisited and presented clear and compelling evidence for a Mg-Fe carbonate component that could be as much as a third of the total mineral abundance. The data from all three instruments in combination are best matched by Mg-Fe carbonate with an abundance of 16-34 wt%. Mini-TES spectra were acquired for 12 targets at various locations on the Comanche (4-5 m long) and Comanche Spur (1-2 m long) outcrops, the latter being the location of the MB and APXS measurements. The two outcrops are spectrally comparable and share similar morphology and texture based on color images from the Panoramic Camera (Pancam). The highest quality Mini-TES spectrum comes from the larger Comanche outcrop on a target named Saupitty. Linear least squares modeling of the Saupitty spectrum employed a library of laboratory spectra tailored for consistency with the APXS and MB data and included spectra representing Martian dust, a “slope” spectrum to account for any temperature determination errors, and a blackbody spectrum to account for differences in spectral contrast between the laboratory and Mini-TES spectra. Successful modeling of the Comanche Saupitty spectrum required one or more carbonate phases to obtain a good fit. Excluding all carbonates from the full starting library more than doubled the root-mean-squared error of the model fit (0.147% vs. 0.299%). Because Mg-Fe carbonate and Ca-Mg carbonate (dolomite) are so spectrally similar over the range used for modeling, both provide a comparable fit. However, Ca-rich carbonates like dolomite are precluded based on APXS data and are inconsistent with MB results. The Comanche carbonate rocks are stratigraphically above a set of olivine-rich volcaniclastic rocks known as Algonquin class that mantle the Haskin Ridge feature of the Columbia Hills. Based on ~50 Mini-TES observations, the Comanche outcrops are the only rocks that host abundant carbonate. However, a target at the base of the larger Comanche outcrop appears spectrally transitional between the carbonate and olivine units. This transitional spectral character applies to additional outcrops a few 10s of meters away from Comanche that also appear stratigraphically transitional. Additional work will attempt to establish whether we are seeing an alteration horizon or depositional unit associated with the emplacement Comanche carbonate. Morris, R. V., et al. (2010), Identification of carbonate-rich outcrops on Mars by the Spirit rover, Science, 329(5990), 421-424.

  7. What Impact Do Chaplains Have? A Pilot Study of Spiritual AIM for Advanced Cancer Patients in Outpatient Palliative Care

    PubMed Central

    Kestenbaum, Allison; Shields, Michele; James, Jennifer; Hocker, Will; Morgan, Stefana; Karve, Shweta; Rabow, Michael W.; Dunn, Laura B.

    2017-01-01

    Context Spiritual care is integral to quality palliative care. Although chaplains are uniquely trained to provide spiritual care, studies evaluating chaplains’ work in palliative care are scarce. Objectives The goals of this pre-post study, conducted among patients with advanced cancer receiving outpatient palliative care, were to evaluate the feasibility and acceptability of chaplain-delivered spiritual care, utilizing the Spiritual Assessment and Intervention Model (“Spiritual AIM”); and to gather pilot data on Spiritual AIM’s effects on spiritual well-being, religious and cancer-specific coping, and physical and psychological symptoms. Methods Patients with advanced cancer (n=31) who were receiving outpatient palliative care were assigned based on chaplains’ and patients’ outpatient schedules, to one of three professional chaplains for three individual Spiritual AIM sessions, conducted over the course of approximately six to eight weeks. Patients completed the following measures at baseline and post-intervention: Edmonton Symptom Assessment Scale (ESAS), Steinhauser spirituality, Brief Religious Coping (Brief RCOPE), Functional Assessment of Chronic Illness Therapy—Spiritual (FACIT-Sp-12), Mini-Mental Adjustment to Cancer (Mini-MAC), Patient Dignity Inventory, Center for Epidemiological Studies – Depression (CES-D, 10-item), and Spielberger State Anxiety Inventory (STAI-S). Results From baseline to post-Spiritual AIM, significant increases were found on the FACIT-Sp-12 Faith subscale, the Mini-MAC Fighting Spirit subscale, and Mini-MAC Adaptive Coping factor. Two trends were observed, i.e., an increase in Positive religious coping and an increase in Fatalism (a subscale of the Mini-MAC). Conclusion Spiritual AIM, a brief chaplain-led intervention, holds potential to address spiritual needs, as well as religious and general coping in patients with serious illnesses. PMID:28736103

  8. What Impact Do Chaplains Have? A Pilot Study of Spiritual AIM for Advanced Cancer Patients in Outpatient Palliative Care.

    PubMed

    Kestenbaum, Allison; Shields, Michele; James, Jennifer; Hocker, Will; Morgan, Stefana; Karve, Shweta; Rabow, Michael W; Dunn, Laura B

    2017-11-01

    Spiritual care is integral to quality palliative care. Although chaplains are uniquely trained to provide spiritual care, studies evaluating chaplains' work in palliative care are scarce. The goals of this pre-post study, conducted among patients with advanced cancer receiving outpatient palliative care, were to evaluate the feasibility and acceptability of chaplain-delivered spiritual care, utilizing the Spiritual Assessment and Intervention Model ("Spiritual AIM"), and to gather pilot data on Spiritual AIM's effects on spiritual well-being, religious and cancer-specific coping, and physical and psychological symptoms. Patients with advanced cancer (N = 31) who were receiving outpatient palliative care were assigned based on chaplains' and patients' outpatient schedules, to one of three professional chaplains for three individual Spiritual AIM sessions, conducted over the course of approximately six to eight weeks. Patients completed the following measures at baseline and post-intervention: Edmonton Symptom Assessment Scale, Steinhauser Spirituality, Brief RCOPE, Functional Assessment of Chronic Illness Therapy-Spiritual (FACIT-Sp-12), Mini-Mental Adjustment to Cancer (Mini-MAC), Patient Dignity Inventory, Center for Epidemiological Studies-Depression (10 items), and Spielberger State Anxiety Inventory. From baseline to post-Spiritual AIM, significant increases were found on the FACIT-Sp-12 Faith subscale, the Mini-MAC Fighting Spirit subscale, and Mini-MAC Adaptive Coping factor. Two trends were observed, i.e., an increase in Positive religious coping on the Brief RCOPE and an increase in Fatalism (a subscale of the Mini-MAC). Spiritual AIM, a brief chaplain-led intervention, holds potential to address spiritual needs and religious and general coping in patients with serious illnesses. Copyright © 2017 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  9. Genotypic and phenotypic characterization of genetic differentiation and diversity in the USDA rice mini-core collection.

    PubMed

    Li, Xiaobai; Yan, Wengui; Agrama, Hesham; Hu, Biaolin; Jia, Limeng; Jia, Melissa; Jackson, Aaron; Moldenhauer, Karen; McClung, Anna; Wu, Dianxing

    2010-12-01

    A rice mini-core collection consisting of 217 accessions has been developed to represent the USDA core and whole collections that include 1,794 and 18,709 accessions, respectively. To improve the efficiency of mining valuable genes and broadening the genetic diversity in breeding, genetic structure and diversity were analyzed using both genotypic (128 molecular markers) and phenotypic (14 numerical traits) data. This mini-core had 13.5 alleles per locus, which is the most among the reported germplasm collections of rice. Similarly, polymorphic information content (PIC) value was 0.71 in the mini-core which is the highest with one exception. The high genetic diversity in the mini-core suggests there is a good possibility of mining genes of interest and selecting parents which will improve food production and quality. A model-based clustering analysis resulted in lowland rice including three groups, aus (39 accessions), indica (71) and their admixtures (5), upland rice including temperate japonica (32), tropical japonica (40), aromatic (6) and their admixtures (12) and wild rice (12) including glaberrima and four other species of Oryza. Group differentiation was analyzed using both genotypic distance Fst from 128 molecular markers and phenotypic (Mahalanobis) distance D(2) from 14 traits. Both dendrograms built by Fst and D(2) reached similar-differentiative relationship among these genetic groups, and the correlation coefficient showed high value 0.85 between Fst matrix and D(2) matrix. The information of genetic and phenotypic differentiation could be helpful for the association mapping of genes of interest. Analysis of genotypic and phenotypic diversity based on genetic structure would facilitate parent selection for broadening genetic base of modern rice cultivars via breeding effort.

  10. Incorporating Inquiry into Upper-Level Homework Assignments: The Mini-Journal

    NASA Astrophysics Data System (ADS)

    Whittington, A. G.; Speck, A. K.; Witzig, S. B.; Abell, S. K.

    2009-12-01

    The U.S. National Science Education Standards provide guidelines for teaching science through inquiry, where students actively develop their understanding of science by combining scientific knowledge with reasoning and thinking skills. Inquiry activities include reading scientific literature, generating hypotheses, designing and carrying out investigations, interpreting data, and formulating conclusions. Inquiry-based instruction emphasizes questions, evidence, and explanation, the essential features of inquiry. As part of an NSF-funded project, “CUES: Connecting Undergraduates to the Enterprise of Science,” new inquiry-based homework materials were developed for two upper-level classes at the University of Missouri: Geochemistry (required for Geology majors), and Solar System Science (open to seniors and graduate students, co-taught and cross-listed between Geology and Physics & Astronomy). We engage students in inquiry-based learning by presenting homework exercises as “mini-journal” articles that follow the format of a scientific journal article, including a title, authors, abstract, introduction, methods, results, discussion and citations to peer-reviewed literature. The mini-journal provides a scaffold and serves as a springboard for students to develop and carry out their own follow-up investigation. They then present their findings in the form of their own mini-journal. Mini-journals replace traditional homework problem sets with a format that more directly reflects and encourages scientific practice. Students are engaged in inquiry-based homework which encompass doing, thinking, and communicating, while the minijournal allows the instructor to contain lines of inquiry within the limits posed by available resources. In the examples we present, research is conducted via spreadsheet modeling, where the students develop their own spreadsheets. The key differences between the old and new formats include (i) the active participation of the students in defining the problem that they will pursue, (ii) the open-ended nature of the inquiry, such that students need to recognize when they have enough information to answer their question, (iii) presentation of results in graphical and tabular formats, and (iv) a written discussion of their findings. We present both the rationale for and concept of using mini-journal homeworks, and provide specific examples we are currently employing in classes. In addition, we explore the challenges (real and perceived) and successes associated with implementing such a technique, and examine student feedback comparing mini-journal and traditional homework formats from the same classes.

  11. Mini-tablets versus pellets as promising multiparticulate modified release delivery systems for highly soluble drugs.

    PubMed

    Gaber, Dina M; Nafee, Noha; Abdallah, Osama Y

    2015-07-05

    Whether mini-tablets (tablets, diameters ≤6mm) belong to single- or multiple-unit dosage forms is still questionable. Accordingly, Pharmacopoeial evaluation procedures for mini-tablets are lacking. In this study, the aforementioned points were discussed. Moreover, their potential for oral controlled delivery was assessed. The antidepressant venlafaxine hydrochloride (Vx), a highly soluble drug undergoing first pass effect, low bioavailability and short half-life was selected as a challenging payload. In an attempt to weigh up mini-tablets versus pellets as multiparticulate carriers, Vx-loaded mini-tablets were compared to formulated pellets of the same composition and the innovator Effexor(®)XR pellets. Formulations were prepared using various polymer hydrogels in the core and ethyl cellulose film coating with increasing thickness. Mini-tablets (diameter 2mm) showed extended Vx release (<60%, 8h). Indeed, release profiles comparable to Effexor(®)XR pellets were obtained. Remarkably higher coating thickness was required for pellets to provide equivalent retardation. Ethyl cellulose in the core ensured faster release due to polymer migration to the surface and pore formation in the coat. mini-tablets showed higher stability to pellets upon storage. Industrially speaking, mini-tablets proved to be superior to pellets in terms of manufacturing, product quality and economical aspects. Results point out the urgent need for standardized evaluation procedures for mini-tablets. Copyright © 2015. Published by Elsevier B.V.

  12. The development and evaluation of mini-GEMs - short, focused, online e-learning videos in geriatric medicine.

    PubMed

    Garside, Mark J; Fisher, James M; Blundell, Adrian G; Gordon, Adam L

    2018-01-01

    Mini Geriatric E-Learning Modules (Mini-GEMs) are short, focused, e-learning videos on geriatric medicine topics, hosted on YouTube, which are targeted at junior doctors working with older people. This study aimed to explore how these resources are accessed and used. The authors analyzed the viewing data from 22 videos published over the first 18 months of the Mini-GEM project. We conducted a focus group of U.K. junior doctors considering their experiences with Mini-GEMS. The Mini-GEMs were viewed 10,291 times over 18 months, equating to 38,435 minutes of total viewing time. The average viewing time for each video was 3.85 minutes. Learners valued the brevity and focused nature of the Mini-GEMs and reported that they watched them in a variety of settings to supplement clinical experiences and consolidate learning. Watching the videos led to an increase in self-reported confidence in managing older patients. Mini-GEMs can effectively disseminate clinical teaching material to a wide audience. The videos are valued by junior doctors due to their accessibility and ease of use.

  13. Impact of implant design on primary stability of orthodontic mini-implants.

    PubMed

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  14. Comparison Between Transverse Mini-Incision and Longitudinal Mini-Incision for the Resection of Locally Advanced Colonic Cancer

    PubMed Central

    Ishida, Hideyuki; Sobajima, Jun; Yokoyama, Masaru; Nakada, Hiroshi; Okada, Norimichi; Kumamoto, Kensuke; Ishibashi, Keiichiro

    2014-01-01

    We performed a retrospective review of non-overweight (body mass index ≤ 25 kg/m2) patients scheduled to undergo a curative resection of locally advanced colon cancer via a transverse mini-incision (n = 62) or a longitudinal mini-incision (skin incision ≤7 cm, n = 62), with the latter group of patients randomly selected as historical controls matched with the former group according to tumor location. Extension of the transverse mini-incision wound was necessary in 3 patients (5%). Both groups were largely equivalent in terms of demographic, clinicopathological, and surgical factors and frequency of postoperative complications. Postoperative analgesic was significantly less (P = 0.04) and postoperative length of the hospital stay was significantly shorter (P < 0.01) in the transverse mini-incision group. Concerning a mini-incision approach for locally advanced colonic cancer, a transverse incision seems to be advantageous with regard to minimal invasiveness and early recovery compared with a longitudinal incision. PMID:24833142

  15. Intrinsic Nucleic Acid Dynamics Modulates HIV-1 Nucleocapsid Protein Binding to Its Targets

    PubMed Central

    Bazzi, Ali; Zargarian, Loussiné; Chaminade, Françoise; De Rocquigny, Hugues; René, Brigitte; Mély, Yves; Fossé, Philippe; Mauffret, Olivier

    2012-01-01

    HIV-1 nucleocapsid protein (NC) is involved in the rearrangement of nucleic acids occurring in key steps of reverse transcription. The protein, through its two zinc fingers, interacts preferentially with unpaired guanines in single-stranded sequences. In mini-cTAR stem-loop, which corresponds to the top half of the cDNA copy of the transactivation response element of the HIV-1 genome, NC was found to exhibit a clear preference for the TGG sequence at the bottom of mini-cTAR stem. To further understand how this site was selected among several potential binding sites containing unpaired guanines, we probed the intrinsic dynamics of mini-cTAR using 13C relaxation measurements. Results of spin relaxation time measurements have been analyzed using the model-free formalism and completed by dispersion relaxation measurements. Our data indicate that the preferentially recognized guanine in the lower part of the stem is exempt of conformational exchange and highly mobile. In contrast, the unrecognized unpaired guanines of mini-cTAR are involved in conformational exchange, probably related to transient base-pairs. These findings support the notion that NC preferentially recognizes unpaired guanines exhibiting a high degree of mobility. The ability of NC to discriminate between close sequences through their dynamic properties contributes to understanding how NC recognizes specific sites within the HIV genome. PMID:22745685

  16. Molecular clouds in the NGC 6334 and NGC 6357 region: Evidence for a 100 pc-scale cloud-cloud collision triggering the Galactic mini-starbursts

    NASA Astrophysics Data System (ADS)

    Fukui, Yasuo; Kohno, Mikito; Yokoyama, Keiko; Torii, Kazufumi; Hattori, Yusuke; Sano, Hidetoshi; Nishimura, Atsushi; Ohama, Akio; Yamamoto, Hiroaki; Tachihara, Kengo

    2018-03-01

    We carried out new CO (J = 1-0, 2-1, and 3-2) observations with NANTEN2 and ASTE in the region of the twin Galactic mini-starbursts NGC 6334 and NGC 6357. We detected two velocity molecular components of 12 km s-1 velocity separation, which is continuous over 3° along the plane. In NGC 6334 the two components show similar two-peaked intensity distributions toward the young H II regions and are linked by a bridge feature. In NGC 6357 we found spatially complementary distribution between the two velocity components as well as a bridge feature in velocity. Based on these results we hypothesize that the two clouds in the two regions collided with each other in the past few Myr and triggered the formation of the starbursts over ˜ 100 pc. We suggest that the formation of the starbursts happened toward the collisional region of extent ˜ 10 pc with initial high molecular column densities. For NGC 6334 we present a scenario which includes spatial variation of the colliding epoch due to non-uniform cloud separation. The scenario possibly explains the apparent age differences among the young O stars in NGC 6334, which range from 104 yr to 106 yr; the latest collision happened within 105 yr toward the youngest stars in NGC 6334 I(N) and I which exhibit molecular outflows without H II regions. For NGC 6357 the O stars were formed a few Myr ago, and the cloud dispersal by the O stars is significant. We conclude that cloud-cloud collision offers a possible explanation of the mini-starburst over a 100 pc scale.

  17. Molecular clouds in the NGC 6334 and NGC 6357 region; Evidence for a 100-pc-scale cloud-cloud collision triggering the Galactic mini-starbursts

    NASA Astrophysics Data System (ADS)

    Fukui, Yasuo; Kohno, Mikito; Yokoyama, Keiko; Torii, Kazufumi; Hattori, Yusuke; Sano, Hidetoshi; Nishimura, Atsushi; Ohama, Akio; Yamamoto, Hiroaki; Tachihara, Kengo

    2018-03-01

    We carried out new CO (J = 1-0, 2-1, and 3-2) observations with NANTEN2 and ASTE in the region of the twin Galactic mini-starbursts NGC 6334 and NGC 6357. We detected two velocity molecular components of 12 km s-1 velocity separation, which is continuous over 3° along the plane. In NGC 6334 the two components show similar two-peaked intensity distributions toward the young H II regions and are linked by a bridge feature. In NGC 6357 we found spatially complementary distribution between the two velocity components as well as a bridge feature in velocity. Based on these results we hypothesize that the two clouds in the two regions collided with each other in the past few Myr and triggered the formation of the starbursts over ˜ 100 pc. We suggest that the formation of the starbursts happened toward the collisional region of extent ˜ 10 pc with initial high molecular column densities. For NGC 6334 we present a scenario which includes spatial variation of the colliding epoch due to non-uniform cloud separation. The scenario possibly explains the apparent age differences among the young O stars in NGC 6334, which range from 104 yr to 106 yr; the latest collision happened within 105 yr toward the youngest stars in NGC 6334 I(N) and I which exhibit molecular outflows without H II regions. For NGC 6357 the O stars were formed a few Myr ago, and the cloud dispersal by the O stars is significant. We conclude that cloud-cloud collision offers a possible explanation of the mini-starburst over a 100-pc scale.

  18. Isothiocyanates, Nitriles, and Epithionitriles from Glucosinolates Are Affected by Genotype and Developmental Stage in Brassica oleracea Varieties.

    PubMed

    Hanschen, Franziska S; Schreiner, Monika

    2017-01-01

    Vegetables of the Brassica oleracea group, such as broccoli, cauliflower, and cabbage, play an important role for glucosinolate consumption in the human diet. Upon maceration of the vegetable tissue, glucosinolates are degraded enzymatically to form volatile isothiocyanates, nitriles, and epithionitriles. However, only the uptake of isothiocyanates is linked to the cancer-preventive effects. Thus, it is of great interest to evaluate especially the isothiocyanate formation. Here, we studied the formation of glucosinolates and their respective hydrolysis products in sprouts and fully developed vegetable heads of different genotypes of the five B. oleracea varieties: broccoli, cauliflower as well as white, red, and savoy cabbages. Further, the effect of ontogeny (developmental stages) during the head development on the formation of glucosinolates and their respective hydrolysis products was evaluated at three different developmental stages (mini, fully developed, and over-mature head). Broccoli and red cabbage were mainly rich in 4-(methylsulfinyl)butyl glucosinolate (glucoraphanin), whereas cauliflower, savoy cabbage and white cabbage contained mainly 2-propenyl (sinigrin) and 3-(methylsulfinyl)propyl glucosinolate (glucoiberin). Upon hydrolysis, epithionitriles or nitriles were often observed to be the main hydrolysis products, with 1-cyano-2,3-epithiopropane being most abundant with up to 5.7 μmol/g fresh weight in white cabbage sprouts. Notably, sprouts often contained more than 10 times more glucosinolates or their hydrolysis products compared to fully developed vegetables. Moreover, during head development, both glucosinolate concentrations as well as hydrolysis product concentrations changed and mini heads contained the highest isothiocyanate concentrations. Thus, from a cancer-preventive point of view, consumption of mini heads of the B. oleracea varieties is recommended.

  19. Molecular clouds in the NGC 6334 and NGC 6357 region: Evidence for a 100 pc-scale cloud-cloud collision triggering the Galactic mini-starbursts

    NASA Astrophysics Data System (ADS)

    Fukui, Yasuo; Kohno, Mikito; Yokoyama, Keiko; Torii, Kazufumi; Hattori, Yusuke; Sano, Hidetoshi; Nishimura, Atsushi; Ohama, Akio; Yamamoto, Hiroaki; Tachihara, Kengo

    2018-05-01

    We carried out new CO (J = 1-0, 2-1, and 3-2) observations with NANTEN2 and ASTE in the region of the twin Galactic mini-starbursts NGC 6334 and NGC 6357. We detected two velocity molecular components of 12 km s-1 velocity separation, which is continuous over 3° along the plane. In NGC 6334 the two components show similar two-peaked intensity distributions toward the young H II regions and are linked by a bridge feature. In NGC 6357 we found spatially complementary distribution between the two velocity components as well as a bridge feature in velocity. Based on these results we hypothesize that the two clouds in the two regions collided with each other in the past few Myr and triggered the formation of the starbursts over ˜ 100 pc. We suggest that the formation of the starbursts happened toward the collisional region of extent ˜ 10 pc with initial high molecular column densities. For NGC 6334 we present a scenario which includes spatial variation of the colliding epoch due to non-uniform cloud separation. The scenario possibly explains the apparent age differences among the young O stars in NGC 6334, which range from 104 yr to 106 yr; the latest collision happened within 105 yr toward the youngest stars in NGC 6334 I(N) and I which exhibit molecular outflows without H II regions. For NGC 6357 the O stars were formed a few Myr ago, and the cloud dispersal by the O stars is significant. We conclude that cloud-cloud collision offers a possible explanation of the mini-starburst over a 100 pc scale.

  20. Isothiocyanates, Nitriles, and Epithionitriles from Glucosinolates Are Affected by Genotype and Developmental Stage in Brassica oleracea Varieties

    PubMed Central

    Hanschen, Franziska S.; Schreiner, Monika

    2017-01-01

    Vegetables of the Brassica oleracea group, such as broccoli, cauliflower, and cabbage, play an important role for glucosinolate consumption in the human diet. Upon maceration of the vegetable tissue, glucosinolates are degraded enzymatically to form volatile isothiocyanates, nitriles, and epithionitriles. However, only the uptake of isothiocyanates is linked to the cancer-preventive effects. Thus, it is of great interest to evaluate especially the isothiocyanate formation. Here, we studied the formation of glucosinolates and their respective hydrolysis products in sprouts and fully developed vegetable heads of different genotypes of the five B. oleracea varieties: broccoli, cauliflower as well as white, red, and savoy cabbages. Further, the effect of ontogeny (developmental stages) during the head development on the formation of glucosinolates and their respective hydrolysis products was evaluated at three different developmental stages (mini, fully developed, and over-mature head). Broccoli and red cabbage were mainly rich in 4-(methylsulfinyl)butyl glucosinolate (glucoraphanin), whereas cauliflower, savoy cabbage and white cabbage contained mainly 2-propenyl (sinigrin) and 3-(methylsulfinyl)propyl glucosinolate (glucoiberin). Upon hydrolysis, epithionitriles or nitriles were often observed to be the main hydrolysis products, with 1-cyano-2,3-epithiopropane being most abundant with up to 5.7 μmol/g fresh weight in white cabbage sprouts. Notably, sprouts often contained more than 10 times more glucosinolates or their hydrolysis products compared to fully developed vegetables. Moreover, during head development, both glucosinolate concentrations as well as hydrolysis product concentrations changed and mini heads contained the highest isothiocyanate concentrations. Thus, from a cancer-preventive point of view, consumption of mini heads of the B. oleracea varieties is recommended. PMID:28690627

  1. Bipolar mixed features - Results from the comparative effectiveness for bipolar disorder (Bipolar CHOICE) study.

    PubMed

    Tohen, Mauricio; Gold, Alexandra K; Sylvia, Louisa G; Montana, Rebecca E; McElroy, Susan L; Thase, Michael E; Rabideau, Dustin J; Nierenberg, Andrew A; Reilly-Harrington, Noreen A; Friedman, Edward S; Shelton, Richard C; Bowden, Charles L; Singh, Vivek; Deckersbach, Thilo; Ketter, Terence A; Calabrese, Joseph R; Bobo, William V; McInnis, Melvin G

    2017-08-01

    DSM-5 changed the criteria from DSM-IV for mixed features in mood disorder episodes to include non-overlapping symptoms of depression and hypomania/mania. It is unknown if, by changing these criteria, the same group would qualify for mixed features. We assessed how those meeting DSM-5 criteria for mixed features compare to those meeting DSM-IV criteria. We analyzed data from 482 adult bipolar patients in Bipolar CHOICE, a randomized comparative effectiveness trial. Bipolar diagnoses were confirmed through the MINI International Neuropsychiatric Interview (MINI). Presence and severity of mood symptoms were collected with the Bipolar Inventory of Symptoms Scale (BISS) and linked to DSM-5 and DSM-IV mixed features criteria. Baseline demographics and clinical variables were compared between mood episode groups using ANOVA for continuous variables and chi-square tests for categorical variables. At baseline, the frequency of DSM-IV mixed episodes diagnoses obtained with the MINI was 17% and with the BISS was 20%. Using DSM-5 criteria, 9% of participants met criteria for hypomania/mania with mixed features and 12% met criteria for a depressive episode with mixed features. Symptom severity was also associated with increased mixed features with a high rate of mixed features in patients with mania/hypomania (63.8%) relative to those with depression (8.0%). Data on mixed features were collected at baseline only and thus do not reflect potential patterns in mixed features within this sample across the study duration. The DSM-5 narrower, non-overlapping definition of mixed episodes resulted in fewer patients who met mixed criteria compared to DSM-IV. Copyright © 2017. Published by Elsevier B.V.

  2. Elicitation of Neutralizing Antibodies Directed against CD4-Induced Epitope(s) Using a CD4 Mimetic Cross-Linked to a HIV-1 Envelope Glycoprotein

    PubMed Central

    Dey, Antu K.; Burke, Brian; Sun, Yide; Sirokman, Klara; Nandi, Avishek; Hartog, Karin; Lian, Ying; Geonnotti, Anthony R.; Montefiori, David; Franti, Michael; Martin, Grégoire; Carfi, Andrea; Kessler, Pascal; Martin, Loïc; Srivastava, Indresh K.; Barnett, Susan W.

    2012-01-01

    The identification of HIV-1 envelope glycoprotein (Env) structures that can generate broadly neutralizing antibodies (BNAbs) is pivotal to the development of a successful vaccine against HIV-1 aimed at eliciting effective humoral immune responses. To that end, the production of novel Env structure(s) that might induce BNAbs by presentation of conserved epitopes, which are otherwise occluded, is critical. Here, we focus on a structure that stabilizes Env in a conformation representative of its primary (CD4) receptor-bound state, thereby exposing highly conserved “CD4 induced” (CD4i) epitope(s) known to be important for co-receptor binding and subsequent virus infection. A CD4-mimetic miniprotein, miniCD4 (M64U1-SH), was produced and covalently complexed to recombinant, trimeric gp140 envelope glycoprotein (gp140) using site-specific disulfide linkages. The resulting gp140-miniCD4 (gp140-S-S-M64U1) complex was recognized by CD4i antibodies and the HIV-1 co-receptor, CCR5. The gp140-miniCD4 complex elicited the highest titers of CD4i binding antibodies as well as enhanced neutralizing antibodies against Tier 1 viruses as compared to gp140 protein alone following immunization of rabbits. Neutralization against HIV-27312/V434M and additional serum mapping confirm the specific elicitation of antibodies directed to the CD4i epitope(s). These results demonstrate the utility of structure-based approach in improving immunogenic response against specific region, such as the CD4i epitope(s) here, and its potential role in vaccine application. PMID:22291921

  3. Mini-marathon groups: psychological "first aid" following disasters.

    PubMed

    Terr, L C

    1992-01-01

    Large group counseling sessions for soldiers following battle have been commonly used since World War II. The author conceptualizes and demonstrates how these mini-marathon sessions can be adapted to support all ages and types of civilians involved in disasters. Mini-marathons take about 3 hours and are divided into three sections: story sharing, symptom sharing, and suggestions for self-help, including sharing tales of heroism and survival. After an initial mini-marathon session, a second session may be held emphasizing creativity. The author also describes how mini-marathons can be adapted for therapists who will lead their own sessions.

  4. Paucity and preferential suppression of transgenes in late replication domains of the D. melanogaster genome.

    PubMed

    Babenko, Vladimir N; Makunin, Igor V; Brusentsova, Irina V; Belyaeva, Elena S; Maksimov, Daniil A; Belyakin, Stepan N; Maroy, Peter; Vasil'eva, Lyubov A; Zhimulev, Igor F

    2010-05-21

    Eukaryotic genomes are organized in extended domains with distinct features intimately linking genome structure, replication pattern and chromatin state. Recently we identified a set of long late replicating euchromatic regions that are underreplicated in salivary gland polytene chromosomes of D. melanogaster. Here we demonstrate that these underreplicated regions (URs) have a low density of P-element and piggyBac insertions compared to the genome average or neighboring regions. In contrast, Minos-based transposons show no paucity in URs but have a strong bias to testis-specific genes. We estimated the suppression level in 2,852 stocks carrying a single P-element by analysis of eye color determined by the mini-white marker gene and demonstrate that the proportion of suppressed transgenes in URs is more than three times higher than in the flanking regions or the genomic average. The suppressed transgenes reside in intergenic, genic or promoter regions of the annotated genes. We speculate that the low insertion frequency of P-elements and piggyBacs in URs partially results from suppression of transgenes that potentially could prevent identification of transgenes due to complete suppression of the marker gene. In a similar manner, the proportion of suppressed transgenes is higher in loci replicating late or very late in Kc cells and these loci have a lower density of P-elements and piggyBac insertions. In transgenes with two marker genes suppression of mini-white gene in eye coincides with suppression of yellow gene in bristles. Our results suggest that the late replication domains have a high inactivation potential apparently linked to the silenced or closed chromatin state in these regions, and that such inactivation potential is largely maintained in different tissues.

  5. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    PubMed

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    PubMed

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  7. CoMiniGut-a small volume in vitro colon model for the screening of gut microbial fermentation processes.

    PubMed

    Wiese, Maria; Khakimov, Bekzod; Nielsen, Sebastian; Sørensen, Helena; van den Berg, Frans; Nielsen, Dennis Sandris

    2018-01-01

    Driven by the growing recognition of the influence of the gut microbiota (GM) on human health and disease, there is a rapidly increasing interest in understanding how dietary components, pharmaceuticals and pre- and probiotics influence GM. In vitro colon models represent an attractive tool for this purpose. With the dual objective of facilitating the investigation of rare and expensive compounds, as well as an increased throughput, we have developed a prototype in vitro parallel gut microbial fermentation screening tool with a working volume of only 5 ml consisting of five parallel reactor units that can be expanded with multiples of five to increase throughput. This allows e.g., the investigation of interpersonal variations in gut microbial dynamics and the acquisition of larger data sets with enhanced statistical inference. The functionality of the in vitro colon model, Copenhagen MiniGut (CoMiniGut) was first demonstrated in experiments with two common prebiotics using the oligosaccharide inulin and the disaccharide lactulose at 1% (w/v). We then investigated fermentation of the scarce and expensive human milk oligosaccharides (HMOs) 3-Fucosyllactose, 3-Sialyllactose, 6-Sialyllactose and the more common Fructooligosaccharide in fermentations with infant gut microbial communities. Investigations of microbial community composition dynamics in the CoMiniGut reactors by MiSeq-based 16S rRNA gene amplicon high throughput sequencing showed excellent experimental reproducibility and allowed us to extract significant differences in gut microbial composition after 24 h of fermentation for all investigated substrates and fecal donors. Furthermore, short chain fatty acids (SCFAs) were quantified for all treatments and donors. Fermentations with inulin and lactulose showed that inulin leads to a microbiota dominated by obligate anaerobes, with high relative abundance of Bacteroidetes, while the more easily fermented lactulose leads to higher relative abundance of Proteobacteria. The subsequent study on the influence of HMOs on two infant GM communities, revealed the strongest bifidogenic effect for 3'SL for both infants. Inter-individual differences of infant GM, especially with regards to the occurrence of Bacteroidetes and differences in bifidobacterial species composition, correlated with varying degrees of HMO utilization foremost of 6'SL and 3'FL, indicating species and strain related differences in HMO utilization which was also reflected in SCFAs concentrations, with 3'SL and 6'SL resulting in significantly higher butyrate production compared to 3'FL. In conclusion, the increased throughput of CoMiniGut strengthens experimental conclusions through elimination of statistical interferences originating from low number of repetitions. Its small working volume moreover allows the investigation of rare and expensive bioactives.

  8. Comparison of the Mini-Balance Evaluations Systems Test with the Berg Balance Scale in relationship to walking speed and motor recovery post stroke.

    PubMed

    Madhavan, Sangeetha; Bishnoi, Alka

    2017-12-01

    The Mini-BESTest is a recently developed balance assessment tool that incorporates challenging dynamic balance tasks. Few studies have compared the psychometric properties of the Mini-BESTest to the commonly used Berg Balance Scale (BBS). However, the utility of these scales in relationship to post stroke walking speeds has not been explored. The purpose of this study was to compare the sensitivity and specificity of the Mini-BESTest and BBS to evaluate walking speeds in individuals with stroke. A retrospective exploratory design. Forty-one individuals with chronic stroke were evaluated with the Mini-BESTest, BBS, and 10-meter self-selected walk test (10MWT). Based on their self-selected gait speeds (below or above 0.8 m/s), participants were classified as slow and fast walkers. Significant linear correlations were observed between the Mini-BESTest vs. BBS (r = 0.72, p ≤ 0.001), Mini-BESTest vs. 10MWT (r = 0.58, p ≤ 0.001), and BBS vs. 10MWT (r = 0.30, p = 0.05). Independent t-tests comparing the balance scores for the slow and fast walkers revealed significant group differences for the Mini-BESTest (p = 0.003), but not for the BBS (p = 0.09). The Mini-BESTest demonstrated higher sensitivity (93%) and specificity (64%) compared to the BBS (sensitivity 81%, specificity 56%) for discriminating participants into slow and fast walkers. The Mini-BESTest has a greater discriminative ability than the BBS to categorize individuals with stroke into slow and fast walkers.

  9. Comparison of the Mini-Balance Evaluations Systems Test with the Berg Balance Scale in relationship to walking speed and motor recovery post stroke

    PubMed Central

    Madhavan, Sangeetha; Bishnoi, Alka

    2017-01-01

    Background The Mini-BESTest is a recently developed balance assessment tool that incorporates challenging dynamic balance tasks. Few studies have compared the psychometric properties of the Mini-BESTest to the commonly used Berg Balance Scale (BBS). However, the utility of these scales in relationship to post stroke walking speeds has not been explored. Objectives The purpose of this study was to compare the sensitivity and specificity of the Mini-BESTest and BBS to evaluate walking speeds in individuals with stroke. Design A retrospective exploratory design. Methods Forty-one individuals with chronic stroke were evaluated with the Mini-BESTest, BBS, and 10-meter self-selected walk test (10MWT). Based on their self-selected gait speeds (below or above 0.8 m/s), participants were classified as slow and fast walkers. Results Significant linear correlations were observed between the Mini-BESTest vs. BBS (r = 0.72, p ≤ 0.001), Mini-BESTest vs. 10MWT (r = 0.58, p ≤ 0.001), and BBS vs. 10MWT (r = 0.30, p = 0.05). Independent t-tests comparing the balance scores for the slow and fast walkers revealed significant group differences for the Mini-BESTest (p =0.003), but not for the BBS (p = 0.09). The Mini-BESTest demonstrated higher sensitivity (93%) and specificity (64%) compared to the BBS (sensitivity 81%, specificity 56%) for discriminating participants into slow and fast walkers. No significant results were observed with the FMLE-M scores. Conclusions The Mini-BESTest has a greater discriminative ability than the BBS to categorize individuals with stroke into slow and fast walkers. PMID:28826325

  10. The Mini-Social Phobia Inventory: psychometric properties in an adolescent general population sample.

    PubMed

    Ranta, Klaus; Kaltiala-Heino, Riittakerttu; Rantanen, Päivi; Marttunen, Mauri

    2012-07-01

    Onset of social phobia (SP) typically occurs in adolescence. Short screening instruments for its assessment are needed for use in primary health and school settings. The 3-item Mini-Social Phobia Inventory (SPIN) has demonstrated effectiveness in screening for generalized SP (GSP) in adults. This study examined the psychometrics of the Mini-SPIN in an adolescent general population sample. Three hundred fifty adolescents aged 12 to 17 years were clinically interviewed using the Schedule for Affective Disorders and Schizophrenia for School-Age Children-Present and Lifetime Version for identification of SP and other Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Axis I disorders, blind to their Mini-SPIN status. Associations between SP; subclinical SP; other anxiety, depressive, and disruptive disorders; and Mini-SPIN scores were examined, and diagnostic efficiency statistics were calculated. The association between Mini-SPIN scores and the generalized subtype of SP was also examined. As in adults, the Mini-SPIN items differentiated subjects with SP from those without. A score of 6 points or greater was found optimal in predicting SP with a sensitivity of 86%, specificity of 84%, and positive and negative predictive values of 26% and 99%. The Mini-SPIN also possessed discriminative validity, as scores were higher for adolescents with SP than they were for those with depressive, disruptive, and other anxiety disorders. The Mini-SPIN was also able to differentiate adolescents with GSP from the rest of the sample. The Mini-SPIN has good psychometrics for screening SP in adolescents from general population and may have value in screening for GSP. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    PubMed

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p < 0.001). Postoperative hemoglobin drop was significantly lower in F-URS group compared to mini-PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  12. Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harper, Meg

    This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of themore » discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.« less

  13. Modeling neutrino-induced charged pion production on water at T2K kinematics

    NASA Astrophysics Data System (ADS)

    Nikolakopoulos, A.; González-Jiménez, R.; Niewczas, K.; Sobczyk, J.; Jachowicz, N.

    2018-05-01

    Pion production is a significant component of the signal in accelerator-based neutrino experiments. Over the last years, the MiniBooNE, T2K, and MINERvA collaborations have reported a substantial amount of data on (anti)neutrino-induced pion production on the nucleus. However, a comprehensive and consistent description of the whole data set is still missing. We aim at improving the current understanding of neutrino-induced pion production on the nucleus. To this end, the comparison of experimental data with theoretical predictions, preferably based on microscopic models, is essential to disentangle the different reaction mechanisms involved in the process. To describe single-pion production, we use a hybrid model that combines low- and a high-energy approaches. The low-energy model contains resonances and background terms. At high invariant masses, a high-energy model based on a Regge approach is employed. The model is implemented in the nucleus using the relativistic plane wave impulse approximation (RPWIA). We present a comparison of the hybrid-RPWIA and low-energy model with the recent neutrino-induced charged-current 1 π+ -production cross section on water reported by T2K. In order to judge the impact of final-state interactions (FSI), we confront our results with those of the nuwro Monte Carlo generator. The hybrid-RPWIA model and nuwro results compare favorably to the data, albeit that FSI are not included in the former. The need of a high-energy model at T2K kinematics is made clear. These results complement our previous work [Phys. Rev. D 97, 013004 (2018), 10.1103/PhysRevD.97.013004], in which we compared the models to the MINERvA and MiniBooNE 1 π+ data. The hybrid-RPWIA model tends to overpredict both the T2K and MINERvA data in kinematic regions where the largest suppression due to FSI is expected and agrees remarkably well with the data in other kinematic regions. On the contrary, the MiniBooNE data are underpredicted over the whole kinematic range.

  14. A Tribute to the Donkey.

    ERIC Educational Resources Information Center

    Marion, L. Marvin

    The "mini-unit" for gifted students at the elementary and middle or junior high school levels presents 27 activities based on B. Bloom, E. P. Torrance, and F. Williams' models of instruction. Activities focus on the theme of the donkey and include such tasks as using nonverbal communication to make a model donkey; brainstorming resources,…

  15. NO2 fluxes from Tijuana using a mobile mini-DOAS during Cal-Mex 2010

    NASA Astrophysics Data System (ADS)

    Rivera, Claudia; Barrera, Hugo; Grutter, Michel; Zavala, Miguel; Galle, Bo; Bei, Naifang; Li, Guohui; Molina, Luisa T.

    2013-05-01

    NO2 fluxes were measured using a mobile mini-DOAS during Cal-Mex 2010 field study, between May 15 and June 30, 2010, from the urban area of Tijuana, Baja California as well as the Rosarito power plant. The average calculated NO2 fluxes were 328 ± 184 (269 ± 201) g s-1, and 23.4 ± 4.9 (12.9 ± 11.9) g s-1 for Tijuana urban area and Rosarito power plant, respectively, using model based wind fields and onsite measurements (in parenthesis). Wind speed and wind direction data needed to estimate the fluxes were both modeled and obtained from radiosondes launched regularly during the field campaign, whereas the mixing layer height throughout the entire field campaign was measured using a ceilometer. Large variations in the NO2 fluxes from both the Tijuana urban area and Rosarito power plant were observed during Cal-Mex 2010; however, the variability was less when model based wind fields were used. Qualitative comparisons of modeled and measured plumes from the Tijuana urban area and Rosarito power plant showed good agreement.

  16. The not-so-sterile 4th neutrino: constraints on new gauge interactions from neutrino oscillation experiments

    NASA Astrophysics Data System (ADS)

    Kopp, Joachim; Welter, Johannes

    2014-12-01

    Sterile neutrino models with new gauge interactions in the sterile sector are phenomenologically interesting since they can lead to novel effects in neutrino oscillation experiments, in cosmology and in dark matter detectors, possibly even explaining some of the observed anomalies in these experiments. Here, we use data from neutrino oscillation experiments, in particular from MiniBooNE, MINOS and solar neutrino experiments, to constrain such models. We focus in particular on the case where the sterile sector gauge boson A ' couples also to Standard Model particles (for instance to the baryon number current) and thus induces a large Mikheyev-Smirnov-Wolfenstein potential. For eV-scale sterile neutrinos, we obtain strong constraints especially from MINOS, which restricts the strength of the new interaction to be less than ˜ 10 times that of the Standard Model weak interaction unless active-sterile neutrino mixing is very small (sin2 θ 24 ≲ 10-3). This rules out gauge forces large enough to affect short-baseline experiments like MiniBooNE and it imposes nontrivial constraints on signals from sterile neutrino scattering in dark matter experiments.

  17. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    PubMed

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  18. A simple three-dimensional stent for proper placement of mini-implant

    PubMed Central

    2013-01-01

    Background This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). Findings The stent is made of 0.018 × 0.025 in. stainless steel archwire which consists of a ‘u loop’ angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the ‘u’ helps in the placement of the mini-implant at 70° to the long axis of the tooth. The vertical height is determined such that the mini-implant is placed at the mucogingival junction. The mini-implant is placed with the aid of the stent, and its angulation and proximity to the adjacent roots are checked with a cone beam computed tomography image. The cone beam computed tomography image showed the mini-implant at an angle of 70° to the long axis of the tooth. There is no contact between mini-implant and the roots of the adjacent teeth. Conclusion This stent is simple, easy to fabricate, cost-effective, and provides ease of insertion/removal, and three-dimensional orientation of the mini-implant. PMID:24326158

  19. [Decision-making and apathy in early stage of Alzheimer's disease and in mild cognitive impairment].

    PubMed

    Jacus, Jean-Pierre; Bayard, Sophie; Raffard, Stéphane; Gély-Nargeot, Marie-Christine

    2013-06-01

    Decision-making and apathy have common neuropsychological processes and neuroanatomical substrates. However, their links in mild cognitive impairment (MCI) and Alzheimer's disease (AD) remain unclear. in order to evaluate these links, we compared 3 groups of 20 control subjects to 20 patients with MCI and 20 patients with mild AD. All participants completed the mini mental state examination (MMSE), the Lille apathy rating scale (LARS, a multidimensional scale of apathy), the game of dice task (GDT, assessing decision under risk) and the Iowa gambling task (IGT, assessing decision under ambiguity). 60% of patients in both clinical groups were apathetic versus 5% of control subjects. In both clinical groups the IGT and GDT net scores were comparable (respectively: p = 0.76 and p = 0.84), while the control group had higher scores than MCI and AD's groups (respectively, GDT p < 0.02 and p < 0.05; IGT: p < 0.05 and p < 0.05). Cognitive impairment increased the risk of disadvantageous choices in decision under risk (× 6), and under ambiguity (× 3.5). No global contribution of apathy was found for decision-making performances (all PS > 0.05), but on the LARS, the "intellectual curiosity" (cognitive dimension) was a predictor for the performances on GDT's (OR = 1.73, p = 0.05), while the "action initiation" (behavioral dimension) was a predictor of those on IGT (OR = 1.57, p = 0.05). these results highlight the behavioral and the cognitive sensitivity of the IGT and the GDT, and are analyzed according to Levy and Dubois's model of apathy, and to the three steps of the decision-making process of Gleichgerrcht et al. (2010). However, more researches are necessary to explain the causality links between action initiation and decision under ambiguity.

  20. Pyruvate dehydrogenase deficiency and epilepsy.

    PubMed

    Prasad, Chitra; Rupar, Tony; Prasad, Asuri N

    2011-11-01

    The pyruvate dehydrogenase complex (PDHc) is a mitochondrial matrix multienzyme complex that provides the link between glycolysis and the tricarboxylic acid (TCA) cycle by catalyzing the conversion of pyruvate into acetyl-CoA. PDHc deficiency is one of the commoner metabolic disorders of lactic acidosis presenting with neurological phenotypes that vary with age and gender. In this mini-review, we postulate mechanisms of epilepsy in the setting of PDHc deficiency using two illustrative cases (one with pyruvate dehydrogenase complex E1-alpha polypeptide (PDHA1) deficiency and the second one with pyruvate dehydrogenase complex E1-beta subunit (PDHB) deficiency (a rare subtype of PDHc deficiency)) and a selected review of published case series. PDHc plays a critical role in the pathway of carbohydrate metabolism and energy production. In severe deficiency states the resulting energy deficit impacts on brain development in utero resulting in structural brain anomalies and epilepsy. Milder deficiency states present with variable manifestations that include cognitive delay, ataxia, and seizures. Epileptogenesis in PDHc deficiency is linked to energy failure, development of structural brain anomalies and abnormal neurotransmitter metabolism. The use of the ketogenic diet bypasses the metabolic block, by providing a direct source of acetyl-CoA, leading to amelioration of some symptoms. Genetic counseling is essential as PDHA1 deficiency (commonest defect) is X-linked although females can be affected due to unfavorable lyonization, while PDHB and PDH phosphatase (PDP) deficiencies (much rarer defects) are of autosomal recessive inheritance. Research is in progress for looking into animal models to better understand pathogenesis and management of this challenging disorder. Copyright © 2011 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  1. Mini-dystrophin Expression Down-regulates Overactivation of G Protein–mediated IP3 Signaling Pathway in Dystrophin-deficient Muscle Cells

    PubMed Central

    Balghi, Haouaria; Sebille, Stéphane; Constantin, Bruno; Patri, Sylvie; Thoreau, Vincent; Mondin, Ludivine; Mok, Elise; Kitzis, Alain; Raymond, Guy; Cognard, Christian

    2006-01-01

    We present here evidence for the enhancement of an inositol 1,4,5-trisphosphate (IP3) mediated calcium signaling pathway in myotubes from dystrophin-deficient cell lines (SolC1(−)) as compared to a cell line from the same origin but transfected with mini-dystrophin (SolD(+)). With confocal microscopy, we demonstrated that calcium rise, induced by the perifusion of a solution containing a high potassium concentration, was higher in SolC1(−) than in SolD(+) myotubes. The analysis of amplitude and kinetics of the calcium increase in SolC1(−) and in SolD(+) myotubes during the exposure with SR Ca2+ channel inhibitors (ryanodine and 2-APB) suggested the presence of two mechanisms of SR calcium release: (1) a fast SR calcium release that depended on ryanodine receptors and (2) a slow SR calcium release mediated by IP3 receptors. Detection analyses of mRNAs (reverse transcriptase [RT]-PCR) and proteins (Western blot and immunolocalization) demonstrated the presence of the three known isoforms of IP3 receptors in both SolC1(−) and SolD(+) myotubes. Furthermore, analysis of the kinetics of the rise in calcium revealed that the slow IP3-dependent release may be increased in the SolC1(−) as compared to the SolD(+), suggesting an inhibitory effect of mini-dystrophin in this signaling pathway. Upon incubation with pertussis toxin (PTX), an inhibitory effect similar to that of the IP3R inhibitor (2-APB) was observed on K+-evoked calcium release. This result suggests the involvement of a Gi protein upstream of the IP3 pathway in these stimulation conditions. A hypothetical model is depicted in which both Gi protein and IP3 production could be involved in K+-evoked calcium release as well as a possible interaction with mini-dystrophin. Our findings demonstrate the existence of a potential relationship between mini-dystrophin and SR calcium release as well as a regulatory role of mini-dystrophin on intracellular signaling. PMID:16446505

  2. Biomechanical behavior of 2-implant-and single-implant-retained mandibular overdentures with conventional or mini implants.

    PubMed

    Pisani, Marina Xavier; Presotto, Anna Gabriella Camacho; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo; Kemmoku, Daniel Takanori; Del Bel Cury, Altair Antoninha

    2018-04-24

    The use of single or mini dental implants to retain mandibular overdentures is still questionable. The purpose of this finite element analysis (FEA) study was to investigate the biomechanical behavior of 2- and single-implant-retained mandibular overdentures with conventional or mini implants. Four 3-dimensional (3D) finite element models were constructed with the following designs of mandibular overdentures: 2 (group 2-C) and single (group 1-C) conventional external hexagon implants with ball or O-ring attachment and 2 (group 2-M) and single (group 1-M) 1-piece mini implants. A 150-N axial load was applied bilaterally and simultaneously on the first molar. Overdenture displacement, von Mises equivalent stress (implants and/or prosthetic components), and maximum principal stresses (peri-implant bone) were recorded numerically and then color-coded and compared among the groups. The overdenture displacement (in mm) was higher for the 1-M (0.16) and 2-M (0.17) groups when compared with 1-C (0.09) and 2-C (0.08). Irrespective of the type of implant, the single-implant groups presented higher values of stress (in MPa) on the implants than did the 2-implant groups (1-C=52.53; 1-M=2.95; 2-C=34.66; 2-M=2.37), ball attachment (1-C=201.33; 2-C=159.06), housing or O-ring (1-C=125.01; 1-M=1.96; 2-C=88.84; 2-M=1.27), and peri-implant cortical bone (1-C=19.37; 1-M=1.47; 2-C=15.70; 2-M=1.06). The mini implant overdentures presented lower stress values on the implants, housing or O-ring, and peri-implant bone than did the conventional implant overdentures, regardless of the number of implants. The 2-implant-retained overdentures exhibited lower stresses than the single- implant-retained overdentures, irrespective of the type of implant. The mini implants demonstrated higher overdenture displacement and lower stresses than did conventional implant overdentures for single- and 2-implant-retained overdentures. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. First Atmospheric Science Results from the Mars Exploration Rovers Mini-TES

    NASA Technical Reports Server (NTRS)

    Smith, Michael D.; Wolff, Michael J.; Lemmon, Mark T.; Spanovich, Nicole; Banfield, Don; Budney, Charles J.; Clancy, R. Todd; Ghosh, Amitabha; Landis, Geoffrey A.; Smith, Peter; hide

    2004-01-01

    Thermal infrared spectra of the martian atmosphere taken by the Miniature Thermal Emission Spectrometer (Mini-TES) were used to determine the atmospheric temperatures in the planetary boundary layer and the column-integrated optical depth of aerosols. Mini-TES observations show the diurnal variation of the martian boundary layer thermal structure, including a near-surface superadiabatic layer during the afternoon and an inversion layer at night. Upward-looking Mini-TES observations show warm and cool parcels of air moving through the Mini-TES field of view on a time scale of 30 seconds. The retrieved dust optical depth shows a downward trend at both sites.

  4. First Atmospheric Science Results from the Mars Exploration Rovers Mini-TES.

    PubMed

    Smith, Michael D; Wolff, Michael J; Lemmon, Mark T; Spanovich, Nicole; Banfield, Don; Budney, Charles J; Clancy, R Todd; Ghosh, Amitabha; Landis, Geoffrey A; Smith, Peter; Whitney, Barbara; Christensen, Philip R; Squyres, Steven W

    2004-12-03

    Thermal infrared spectra of the martian atmosphere taken by the Miniature Thermal Emission Spectrometer (Mini-TES) were used to determine the atmospheric temperatures in the planetary boundary layer and the column-integrated optical depth of aerosols. Mini-TES observations show the diurnal variation of the martian boundary layer thermal structure, including a near-surface superadiabatic layer during the afternoon and an inversion layer at night. Upward-looking Mini-TES observations show warm and cool parcels of air moving through the Mini-TES field of view on a time scale of 30 seconds. The retrieved dust optical depth shows a downward trend at both sites.

  5. New light Higgs boson and short-baseline neutrino anomalies

    NASA Astrophysics Data System (ADS)

    Asaadi, J.; Church, E.; Guenette, R.; Jones, B. J. P.; Szelc, A. M.

    2018-04-01

    The low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for nonzero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward scattering off of a locally overdense relic neutrino background give rise to a novel matter effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino- and antineutrino-mode data sets. The model provides substantially improved χ2 values beyond either the no-oscillation hypothesis or the more commonly explored 3 +1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming short-baseline neutrino program at Fermilab, presenting opportunities for further exploration.

  6. Effects of Bisphenol A and its Analogs on Reproductive Health: A Mini Review.

    PubMed

    Siracusa, Jacob Steven; Yin, Lei; Measel, Emily; Liang, Shenuxan; Yu, Xiaozhong

    2018-06-17

    Known endocrine disruptor bisphenol A (BPA) has been shown to be a reproductive toxicant in animal models. Its structural analogs: bisphenol S (BPS), bisphenol F (BPF), bisphenol AF (BPAF), and tetrabromobisphenol A (TBBPA) are increasingly being used in consumer products. However, these analogs may exert similar adverse effects on the reproductive system, and their toxicological data are still limited. This mini-review examined studies on both BPA and BPA analog exposure and reproductive toxicity. It outlines the current state of knowledge on human exposure, toxicokinetics, endocrine activities, and reproductive toxicities of BPA and its analogs. BPA analogs showed similar endocrine potencies when compared to BPA, and emerging data suggest they may pose threats as reproductive hazards in animal models. While evidence based on epidemiological studies is still weak, we have utilized current studies to highlight knowledge gaps and research needs for future risk assessments. Copyright © 2018. Published by Elsevier Inc.

  7. Fluorescence decay of naphthalene studied in an electrostatic storage ring, the Mini-Ring

    NASA Astrophysics Data System (ADS)

    Martin, S.; Matsumoto, J.; Kono, N.; Ji, M.-C.; Brédy, R.; Bernard, J.; Cassimi, A.; Chen, L.

    2017-10-01

    The cooling of naphthalene cations (C10H8)+ has been studied in a compact electrostatic ion storage ring, the Mini-Ring. A nano second laser pulse of 532 nm (2.33 eV) was used to probe the internal energy distribution every millisecond during the storage time up to 5 ms. The evolution of the internal energy distribution of the stored ions was simulated with a model taking into account the dissociation and the radiative decay processes. Calculated decay curves were fitted to the corresponding laser induced neutral decays. For a laser power of 200 μJ/pulse, a good agreement between experiment and modeling was found using an initial Gaussian energy distribution centered to 5.9 eV and a fluorescence decay rate varying from 200 to 300 s-1 in the energy range from 6 to 7 eV. This fast decay was attributed to the delayed Poincaré fluorescence process.

  8. Development and Assessment of the Multiple Mini-Interview in a School of Pharmacy Admissions Model

    PubMed Central

    McLaughlin, Jacqueline E.; Singer, David; Lewis, Margaret; Dinkins, Melissa M.

    2015-01-01

    Objective. To describe the development, implementation, and evaluation of the multiple mini-interview (MMI) within a doctor of pharmacy (PharmD) admissions model. Methods. Demographic data and academic indicators were collected for all candidates who participated in Candidates’ Day (n=253), along with the score for each MMI station criteria (7 stations). A survey was administered to all candidates who completed the MMI, and another survey was administered to all interviewers to examine perceptions of the MMI. Results. Analyses suggest that MMI stations assessed different attributes as designed, with Cronbach alpha for each station ranging from 0.90 to 0.95. All correlations between MMI station scores and academic indicators were negligible. No significant differences in average station scores were found based on age, gender, or race. Conclusion. This study provides additional support for the use of the MMI as an admissions tool in pharmacy education. PMID:26089562

  9. Arc-to-Arc mini-sling 1999: a critical analysis of concept and technology.

    PubMed

    Palma, Paulo

    2011-01-01

    The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique) a less invasive mid-urethral sling using bovine pericardium as the sling material. The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line) was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.

  10. Corneal oedema in a unilateral corneal graft patient induced by high Dk mini-scleral contact lens.

    PubMed

    Guillon, Natalie C; Godfrey, Andrew; Hammond, David S

    2018-05-24

    Scleral contact lenses are increasingly becoming accepted as the method of choice for visual correction of the irregular cornea. As such, cases have surfaced which demonstrate complications arising from mini-scleral lenses. Identification of these issues and adjusting fitting techniques accordingly is necessary for reducing the risks associated with mini-scleral lens wear. A 58 year old Caucasian female was referred for rigid gas permeable contact lens fitting for correction of right irregular astigmatism post penetrating keratoplasty. After four months of successful mini-scleral contact lens wear, the patient experienced a graft rejection episode and treated accordingly, then refit with a new mini-scleral lens. Five months after the lens refit, the patient presented with complaints of hazy vision, and a diagnosis of lens-induced corneal oedema made. Increased awareness of the potential complications of mini-scleral lenses is necessary to encourage and enforce mini-scleral lens fitting techniques that meet the requirements of minimum vault but adequate protection of the compromised cornea. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. Sterile Neutrino Searches in MiniBooNE and MicroBooNE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ignarra, Christina M.

    Tension among recent short baseline neutrino experiments has pointed toward the possible need for the addition of one or more sterile (non-interacting) neutrino states into the existing neutrino oscillation framework. This thesis fi rst presents the motivation for sterile neutrino models by describing the short-baseline anomalies that can be addressed with them. This is followed by a discussion of the phenomenology of these models. The MiniBooNE experiment and results are then described in detail, particularly the most recent antineutrino analysis. This will be followed by a discussion of global fits to world data, including the anomalous data sets. Lastly, futuremore » experiments will be addressed, especially focusing on the MicroBooNE experiment and light collection studies. In particular, understanding the degradation source of TPB, designing the TPB-coated plates for MicroBooNE and developing lightguide collection systems will be discussed. We find an excess of events in the MiniBooNE antineutrino mode results consistent with the LSND anomaly, but one that has a di fferent energy dependence than the low-energy excess reported in neutrino mode. This disagreement creates tension within global fi ts which include up to three sterile neutrinos. The low-energy excess will be addressed by the MicroBooNE experiment, which is expected to start taking data in early 2015. Tension among existing experiments calls for additional, more decisive future experiments.« less

  12. Progress, challenges and perspectives on fish gamete cryopreservation: A mini-review.

    PubMed

    Asturiano, Juan F; Cabrita, Elsa; Horváth, Ákos

    2017-05-01

    Protocols for the cryopreservation of fish gametes have been developed for many different fish species, in special, freshwater salmonids and cyprinids. Methods for sperm freezing have progressed during the last decades due to the increasing number of potential applications: aquaculture (genetic improvement programs, broodstock management, helping with species having reproductive problems), biotechnology studies using model fish species (preservation of transgenic or mutant lines), cryobanking of genetic resources from endangered species, etc. This mini-review tries to give an overview of the present situation of this area of research, identifying the main challenges and perspectives, redirecting the reader to more in-depth reviews and papers. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Why are mini-implants lost: the value of the implantation technique!

    PubMed

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  14. VAST 2010 Challenge: Arms Dealings and Pandemics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grinstein, Georges; Konecni, Shawn; Plaisant, Catherine

    2010-10-23

    The 5th VAST Challenge consisted of three mini-challenges that involved both intelligence analysis and bioinformatics. Teams could solve one, two or all three mini-challenges and assess the overall situation to enter the Grand Challenge. Mini-challenge one involved text reports about people and events giving information about arms dealers, situations in various countries and linkages between different countries. Mini-challenge two involved hospital admission and death records from various countries providing information about the spread of a world wide pandemic. Mini-challenge three involved genetic data to be used to identify the origin of the pandemic and the most dangerous viral mutations. Themore » Grand Challenge was to determine how these various mini-challenges were connected. As always the goal was to analyze the data and provide novel interactive visualizations useful in the analytic process. We received 58 submissions in total and gave 15 awards.« less

  15. Residency Mini-fellowships in the PGY-5 Year: Is There Added Value?

    PubMed

    Shenoy-Bhangle, Anuradha S; Eisenberg, Ronald L; Fineberg, Tabitha; Slanetz, Priscilla J

    2018-06-01

    With the restructuring of radiology board certification, many residencies created PGY-5 "mini-fellowships," during which residents spend focused time pursuing advanced subspecialty training or developing nonclinical skills in leadership, health policy and health-care economics, education, quality improvement, informatics, research, or global health. We surveyed graduates of an academic diagnostic radiology residency to assess the relative value and impact of PGY-5 mini-fellowships on career satisfaction and success. From 2012 to 2016, 39 radiology residents at our institution were offered the opportunity to pursue a 3- to 6-month mini-fellowship during the PGY-5 year. Thirty of 39 radiology residents (77%) participated, whereas 9 of 39 (23%) opted out. Of 39 residents, 13 completed two clinical mini-fellowships, 3 completed research mini-fellowships only, and 14 completed one nonclinical and one clinical mini-fellowship. Through SurveyMonkey, 23 of 39 residents (59%) responded to a questionnaire that collected basic demographic information and asked respondents about the value of this experience as it relates to fellowship choice and career using a five-point Likert scale. Of 23 respondents (14 male, 8 female,1 not specified), 78.3% practice in an academic university-based setting, with 8.7% in a community-based hospital practice, 4.3% in the veterans system, and 4.3% in a private practice setting. Of 23 respondents, the most popular clinical mini-fellowships were magnetic resonance imaging (31.6%), neuroradiology (21.1%), and interventional radiology (15.8%). For nonclinical mini-fellowships, the most popular were research (10.5%), education (10.5%), global health (5.3%), and healthcare economics (5.3%). Of 23 respondents who did mini-fellowships, 95% felt that the mini-fellowship prepared them well for their career, 85% felt it gave them the necessary skills to succeed, 85% cited that it gave them additional skills beyond their peers, and 40% felt it helped them create a life-long connection to a mentor. Ninety-five percent of respondents would choose to do the mini-fellowship again. Respondents suggested increasing the duration to 6-9 months and to develop a more structured curriculum and mentorship component. Only one respondent felt that the nonclinical mini-fellowship took away time from furthering clinical skills. Graduates of a university-affiliated academic radiology residency who participated in clinical and nonclinical mini-fellowships during the PGY-5 year of residency greatly value this experience and uniformly recommend that this type of program continue to be offered to trainees given its ability to develop skills perceived to be vital to ultimate career satisfaction and success. Published by Elsevier Inc.

  16. Comparison and verification of two models which predict minimum principal in situ stress from triaxial data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harikrishnan, R.; Hareland, G.; Warpinski, N.R.

    This paper evaluates the correlation between values of minimum principal in situ stress derived from two different models which use data obtained from triaxial core tests and coefficient for earth at rest correlations. Both models use triaxial laboratory tests with different confining pressures. The first method uses a vcrified fit to the Mohr failure envelope as a function of average rock grain size, which was obtained from detailed microscopic analyses. The second method uses the Mohr-Coulomb failure criterion. Both approaches give an angle in internal friction which is used to calculate the coefficient for earth at rest which gives themore » minimum principal in situ stress. The minimum principal in situ stress is then compared to actual field mini-frac test data which accurately determine the minimum principal in situ stress and are used to verify the accuracy of the correlations. The cores and the mini-frac stress test were obtained from two wells, the Gas Research Institute`s (GRIs) Staged Field Experiment (SFE) no. 1 well through the Travis Peak Formation in the East Texas Basin, and the Department of Energy`s (DOE`s) Multiwell Experiment (MWX) wells located west-southwest of the town of Rifle, Colorado, near the Rulison gas field. Results from this study indicates that the calculated minimum principal in situ stress values obtained by utilizing the rock failure envelope as a function of average rock grain size correlation are in better agreement with the measured stress values (from mini-frac tests) than those obtained utilizing Mohr-Coulomb failure criterion.« less

  17. Comparison of retrograde intrarenal surgery and mini-percutaneous nephrolithotomy in management of lower-pole renal stones with a diameter of smaller than 15 mm.

    PubMed

    Kirac, Mustafa; Bozkurt, Ömer Faruk; Tunc, Lutfi; Guneri, Cagri; Unsal, Ali; Biri, Hasan

    2013-06-01

    The aim of this study was to compare the outcomes of retrograde intrarenal surgery (RIRS) and miniaturized percutaneous nephrolithotomy (mini-PNL) in management of lower-pole renal stones with a diameter smaller than 15 mm. Between December 2009 and July 2012, the patients with the diagnosis of lower-pole stones were evaluated by ultrasonography, intravenous pyelography and computed tomography. The records of 73 evaluable patients who underwent mini-PNL (n = 37) or RIRS (n = 36) for lower-pole (LP) stones with diameter smaller than 15 mm were reviewed retrospectively. Of the 73 patients, 37 underwent mini-PNL and 36 underwent RIRS. The stone-free rates were 89.1 and 88.8 % for mini-PNL and RIRS groups, respectively. The mean operation time was 53.7 ± 14.5 in the mini-PNL group but 66.4 ± 15.8 in the RIRS group (P = 0.01). The mean fluoroscopy times and hospitalization times were significantly higher in the mini-PNL group. There was no major complication in any patient. RIRS and mini-PNL are safe and effective methods for treatment of LP calculi with a diameter smaller than 15 mm. RIRS is a non-invasive and feasible treatment option, and has also short hospitalization time, low morbidity and complication rate. It may be an alternative of mini-PNL in the treatment LP calculi with smaller than 15 mm.

  18. Self-controlled learning benefits: exploring contributions of self-efficacy and intrinsic motivation via path analysis.

    PubMed

    Ste-Marie, Diane M; Carter, Michael J; Law, Barbi; Vertes, Kelly; Smith, Victoria

    2016-09-01

    Research has shown learning advantages for self-controlled practice contexts relative to yoked (i.e., experimenter-imposed) contexts; yet, explanations for this phenomenon remain relatively untested. We examined, via path analysis, whether self-efficacy and intrinsic motivation are important constructs for explaining self-controlled learning benefits. The path model was created using theory-based and empirically supported relationships to examine causal links between these psychological constructs and physical performance. We hypothesised that self-efficacy and intrinsic motivation would have greater predictive power for learning under self-controlled compared to yoked conditions. Participants learned double-mini trampoline progressions, and measures of physical performance, self-efficacy and intrinsic motivation were collected over two practice days and a delayed retention day. The self-controlled group (M = 2.04, SD = .98) completed significantly more skill progressions in retention than their yoked counterparts (M = 1.3, SD = .65). The path model displayed adequate fit, and similar significant path coefficients were found for both groups wherein each variable was predominantly predicted by its preceding time point (e.g., self-efficacy time 1 predicts self-efficacy time 2). Interestingly, the model was not moderated by group; thus, failing to support the hypothesis that self-efficacy and intrinsic motivation have greater predictive power for learning under self-controlled relative to yoked conditions.

  19. Perceptual and neural responses to sweet taste in humans and rodents.

    PubMed

    Lemon, Christian H

    2015-08-01

    This mini-review discusses some of the parallels between rodent neurophysiological and human psychophysical data concerning temperature effects on sweet taste. "Sweet" is an innately rewarding taste sensation that is associated in part with foods that contain calories in the form of sugars. Humans and other mammals can show unconditioned preference for select sweet stimuli. Such preference is poised to influence diet selection and, in turn, nutritional status, which underscores the importance of delineating the physiological mechanisms for sweet taste with respect to their influence on human health. Advances in our knowledge of the biology of sweet taste in humans have arisen in part through studies on mechanisms of gustatory processing in rodent models. Along this line, recent work has revealed there are operational parallels in neural systems for sweet taste between mice and humans, as indexed by similarities in the effects of temperature on central neurophysiological and psychophysical responses to sucrose in these species. Such association strengthens the postulate that rodents can serve as effective models of particular mechanisms of appetitive taste processing. Data supporting this link are discussed here, as are rodent and human data that shed light on relationships between mechanisms for sweet taste and ingestive disorders, such as alcohol abuse. Rodent models have utility for understanding mechanisms of taste processing that may pertain to human flavor perception. Importantly, there are limitations to generalizing data from rodents, albeit parallels across species do exist.

  20. Indicators of Dysphagia in Aged Care Facilities.

    PubMed

    Pu, Dai; Murry, Thomas; Wong, May C M; Yiu, Edwin M L; Chan, Karen M K

    2017-09-18

    The current cross-sectional study aimed to investigate risk factors for dysphagia in elderly individuals in aged care facilities. A total of 878 individuals from 42 aged care facilities were recruited for this study. The dependent outcome was speech therapist-determined swallowing function. Independent factors were Eating Assessment Tool score, oral motor assessment score, Mini-Mental State Examination, medical history, and various functional status ratings. Binomial logistic regression was used to identify independent variables associated with dysphagia in this cohort. Two statistical models were constructed. Model 1 used variables from case files without the need for hands-on assessment, and Model 2 used variables that could be obtained from hands-on assessment. Variables positively associated with dysphagia identified in Model 1 were male gender, total dependence for activities of daily living, need for feeding assistance, mobility, requiring assistance walking or using a wheelchair, and history of pneumonia. Variables positively associated with dysphagia identified in Model 2 were Mini-Mental State Examination score, edentulousness, and oral motor assessments score. Cognitive function, dentition, and oral motor function are significant indicators associated with the presence of swallowing in the elderly. When assessing the frail elderly, case file information can help clinicians identify frail elderly individuals who may be suffering from dysphagia.

  1. Modeling Image Patches with a Generic Dictionary of Mini-Epitomes

    PubMed Central

    Papandreou, George; Chen, Liang-Chieh; Yuille, Alan L.

    2015-01-01

    The goal of this paper is to question the necessity of features like SIFT in categorical visual recognition tasks. As an alternative, we develop a generative model for the raw intensity of image patches and show that it can support image classification performance on par with optimized SIFT-based techniques in a bag-of-visual-words setting. Key ingredient of the proposed model is a compact dictionary of mini-epitomes, learned in an unsupervised fashion on a large collection of images. The use of epitomes allows us to explicitly account for photometric and position variability in image appearance. We show that this flexibility considerably increases the capacity of the dictionary to accurately approximate the appearance of image patches and support recognition tasks. For image classification, we develop histogram-based image encoding methods tailored to the epitomic representation, as well as an “epitomic footprint” encoding which is easy to visualize and highlights the generative nature of our model. We discuss in detail computational aspects and develop efficient algorithms to make the model scalable to large tasks. The proposed techniques are evaluated with experiments on the challenging PASCAL VOC 2007 image classification benchmark. PMID:26321859

  2. Environmental Assessment: Proposed Construction of Army and Air Force Exchange Service Mini-Mall

    DTIC Science & Technology

    2003-10-01

    fast food style restaurant would be accommodated in the mini-mall. Data on electrical consumption for the Burger King restaurant at MAFB (Building...MAFB-Gunter Annex. Assuming the new restaurant in the mini-mall consumes approximately the same quantity of electricity annually as the Burger King ...in the mini-mall. Data on natural gas consumption for the Burger King restaurant at MAFB (Building 1087) in FY 2001 reveals that this facility

  3. Developments in Miniaturized Laser Heterodyne Radiometer (mini-LHR) construction for groundtruth measurements of CH4 and CO2 in harsh terrain

    NASA Astrophysics Data System (ADS)

    DiGregorio, A.; Wilson, E. L.; Hoffman, C.; Grunberg, C.; Mao, J.; Ramanathan, A. K.

    2016-12-01

    We present an updated, ruggedized design of NASA Goddard Space Flight Center's Miniaturized Laser Heterodyne Radiometer (mini-LHR), and the results of testing in the Bonanza Creek Research Forest. The mini-LHR is a passive variation of typical heterodyne radiometry instruments, designed to work in tandem with the AERONET sun photometer for collection of column methane (CH4) and carbon dioxide (CO2) in harsh environments. Advancements in the development of the Cube-Sat version of the mini-LHR have allowed a more than 50% reduction in size, weight, and power usage of the mini-LHR. Now small enough to fit in a medium handbag, the mini-LHR can be run off of a small 35 Watt solar panel and backup battery for continuous measurement. Using a touch-screen control interface built off of a Raspberry Pi, the updated mini-LHR is capable of data collection and preliminary data processing, even without internet, cellular, or satellite connectivity. The improvements made to the mini-LHR were tested in a field campaign in May 2016 funded under NASA's IDS program to track CH4 and CO2 emissions above thawing permafrost. In addition to being a comprehensive study of methane release from thawing permafrost, this pilot study tested the ruggedization and functionality of the instrument in three different environments- a black spruce forest, collapsed scar bog, and fen.

  4. Thermochemistry and Photochemistry in Thick Atmospheres on Super Earths and Mini Neptunes

    NASA Astrophysics Data System (ADS)

    Hu, R.; Seager, S.

    2013-12-01

    Dectection and characterization of low-mass exoplanets is poised to accelerate in the coming decade. Some low-mass exoplanets, namely super Earths and some mini Neptunes, will likely have thick atmospheres that are not H2-dominated. We have developed a photochemistry-thermochemistry model for exploring the compositions of thick atmospheres on super Earths and mini Neptunes, applicable for both H2-dominated atmospheres and non-H2-dominated atmospheres. Using this model, we have simulated the molecular composition of thick atmospheres on warm and hot super Earths/mini Neptunes, and classified thick atmospheres into hydrogen-rich atmospheres, water-rich atmospheres, oxygen-rich atmospheres, and hydrocarbon-rich atmospheres, depending on the hydrogen abundance and the carbon to oxygen abundance ratio. We find that carbon has to be in the form of CO2 rather than CH4 or CO in an H2-depleted water-dominated thick atmosphere, and that the preferred loss of light elements from an oxygen-poor carbon-rich atmosphere leads to formation of unsaturated hydrocarbons. For future observations, we find for GJ 1214b that (1) C2H2 features at 1.0 and 1.5 μm in transmission are diagnostic for hydrocarbon-rich atmospheres; (2) a constraint on the thermal emission at 4.5 μm could differentiate water-rich atmospheres versus hydrocarbon-rich atmospheres; (3) a detection of water-vapor features and a confirmation of nonexistence of methane features would provide sufficient evidence for a water-dominated atmosphere. For a hot super Earth like 55 Cnc e, the diagnostic features of water-rich atmospheres (H2O) and the diagnostic features of hydrocarbon-rich atmospheres (CO and C2H2) are well separated in transmission spectra at 0.6-5 μm, which would enable straightforward characterization. In general, our simulations show that chemical stability has to be taken into account when interpreting the spectrum of a super Earth/mini Neptune. Theoretical transmission spectra and thermal emission spectra of non-H2-dominated atmospheres on GJ 1214b based on photochemistry-thermochemistry simulations in comparison with current observations. The simulated spectra are for an hydrogen abundance of 0.5 and a variety of carbon to oxygen ratios ranging from oxygen rich to carbon rich. The atmospheric scenarios with different carbon to oxygen ratios can be constrained via the spectral features of their hallmark molecules.

  5. Yeast cohesin complex embraces 2 micron plasmid sisters in a tri-linked catenane complex

    PubMed Central

    Ghosh, Santanu K.; Huang, Chu-Chun; Hajra, Sujata; Jayaram, Makkuni

    2010-01-01

    Sister chromatid cohesion, crucial for faithful segregation of replicated chromosomes in eukaryotes, is mediated by the multi-subunit protein complex cohesin. The Saccharomyces cerevisiae plasmid 2 micron circle mimics chromosomes in assembling cohesin at its partitioning locus. The plasmid is a multi-copy selfish DNA element that resides in the nucleus and propagates itself stably, presumably with assistance from cohesin. In metaphase cell lysates, or fractions enriched for their cohesed state by sedimentation, plasmid molecules are trapped topologically by the protein ring formed by cohesin. They can be released from cohesin’s embrace either by linearizing the DNA or by cleaving a cohesin subunit. Assays using two distinctly tagged cohesin molecules argue against the hand-cuff (an associated pair of monomeric cohesin rings) or the bracelet (a dimeric cohesin ring) model as responsible for establishing plasmid cohesion. Our cumulative results most easily fit a model in which a single monomeric cohesin ring, rather than a series of such rings, conjoins a pair of sister plasmids. These features of plasmid cohesion account for its sister-to-sister mode of segregation by cohesin disassembly during anaphase. The mechanistic similarities of cohesion between mini-chromosome sisters and 2 micron plasmid sisters suggest a potential kinship between the plasmid partitioning locus and centromeres. PMID:19920123

  6. Modeling the Association between 43 Different Clinical and Pathological Variables and the Severity of Cognitive Impairment in a Large Autopsy Cohort of Elderly Persons

    PubMed Central

    Nelson, Peter T.; Abner, Erin L.; Schmitt, Frederick A.; Kryscio, Richard J.; Jicha, Gregory A.; Smith, Charles D.; Davis, Daron G.; Poduska, John W.; Patel, Ela; Mendiondo, Marta S.; Markesbery, William R.

    2009-01-01

    We evaluated the association between mini-mental status examination (MMSE) scores proximal to death and the values of 43 different clinical and pathological parameters. Studies were performed using data from 334 elderly, longitudinally evaluated research subjects who had undergone autopsy and satisfied inclusion criteria from an initial study group of 501. Interindividual variance in MMSE scores was used as a surrogate for the severity of cognitive impairment linked to aging (CILA). A statistical linear regression-based model provided a framework for assessing the parameters with significant, direct impact on CILA severity. Strong association between CILA and Alzheimer’s disease (AD) pathology, especially isocortical neurofibrillary tangles, was evident. The pattern of association between AD lesion densities with cognitive impairment severity was biologically informative, with neuritic plaques having more impact in relatively high-functioning individuals. Abundant isocortical Lewy bodies tended to be an additive pathology correlating with final MMSE scores approximately 10 points lower. In a subset of cases we found evidence for association between TDP-43-related pathology and CILA severity, independent of AD or hippocampal sclerosis. There was no support for independent association between CILA severity and most evaluated indices including diffuse plaques, argyrophilic grains, heart disease, education level, apolipoprotein E alleles or diabetes. PMID:19021630

  7. MINI PILOT PLANT FOR DRINKING WATER RESEARCH

    EPA Science Inventory

    The Water Supply & Water Resources Division (WSWRD) has constructed 2 mini-pilot plant systems used to conduct drinking water research. These two systems each have 2 parallel trains for comparative research. The mini-pilot plants are small conventional drinking water treatment ...

  8. Neuroprotective effect of lidocaine: is there clinical potential?

    PubMed Central

    Leng, Tiandong; Gao, Xiuren; Dilger, James P; Lin, Jun

    2016-01-01

    Local anesthetic lidocaine has been shown to be protective in animal models of focal and global ischemia as well as in in vitro hypoxic models. Lidocaine has been tested in patients for its potential protective effect on postoperative cognitive dysfunction. This mini-review summarizes the laboratory and clinical evidences and discusses its clinical applications as neuroprotective agent. PMID:27186318

  9. Reduction of Spectral Interferences in Inductively Coupled Plasma-Atomic Emission Spectrometry by Selective Spectral-Line Modulation.

    DTIC Science & Technology

    1982-05-13

    11/03 laboratory mini- computer (Maynard, MA) Boxcar Amplifier: Model 162 Boxcar averager with model 164 input gates (Princeton Applied Research Corp...nn! Office Attn: Der A. B. Amster, Attn: Dv. I. P. Peebles Chemitry Division .%,!l3I1rg 1;4, Section D China Lake, California 93555 666 Summer

  10. Alternate Service Delivery Models in Cancer Genetic Counseling: A Mini-Review.

    PubMed

    Buchanan, Adam Hudson; Rahm, Alanna Kulchak; Williams, Janet L

    2016-01-01

    Demand for cancer genetic counseling has grown rapidly in recent years as germline genomic information has become increasingly incorporated into cancer care, and the field has entered the public consciousness through high-profile celebrity publications. Increased demand and existing variability in the availability of trained cancer genetics clinicians place a priority on developing and evaluating alternate service delivery models for genetic counseling. This mini-review summarizes the state of science regarding service delivery models, such as telephone counseling, telegenetics, and group counseling. Research on comparative effectiveness of these models in traditional individual, in-person genetic counseling has been promising for improving access to care in a manner acceptable to patients. Yet, it has not fully evaluated the short- and long-term patient- and system-level outcomes that will help answer the question of whether these models achieve the same beneficial psychosocial and behavioral outcomes as traditional cancer genetic counseling. We propose a research agenda focused on comparative effectiveness of available service delivery models and how to match models to patients and practice settings. Only through this rigorous research can clinicians and systems find the optimal balance of clinical quality, ready and secure access to care, and financial sustainability. Such research will be integral to achieving the promise of genomic medicine in oncology.

  11. History and current status of mini-invasive thoracic surgery

    PubMed Central

    He, Jianxing

    2011-01-01

    Mini-invasive thoracic technique mainly refers to a technique involving the significant reduction of the chest wall access-related trauma. Notably, thoracoscope is the chief representative. The development of thoracoscope technique is characterized by: developing from direct peep to artificial lighting, then combination with image and video technique in equipments; technically developing from diagnostic to therapeutic approaches; developing from simpleness to complexity in application scope; and usually developing together with other techniques. At present, the widely used mini-invasive thoracic surgery refers to the mini-open thoracic surgery performed mainly by using some instruments to control target tissues and organs based on the vision associated with multi-limb coordination, which may be hand-assisted if necessary. The mini-invasive thoracic surgery consists of three approaches including video-assisted thoracic surgery (VATS), video-assisted Hybrid and hand-assisted VATS. So far the mini-invasive thoracic technique has achieved great advances due to the development in instruments of mini-invasive thoracic surgery which has the following features: instruments of mini-invasive thoracic surgery appear to be safe and practical, and have successive improvement and diversification in function; the specific instruments of open surgeries has been successively developed into dedicated instruments of endoscopic surgery; the application of endoscopic mechanical suture device generates faster fragmentation and reconstruction of organ tissues; the specific delicated instruments of endoscopic surgery have rapid development and application; and the simple instruments structurally similar to the conventional instruments are designed according to the mini-incison. In addition, the mini-invasive thoracic technique is widely used in five aspects including diseases of pleura membrane and chest wall, lung diseases, esophageal diseases, mediastinal diseases and heart diseases. However, there remain many problems in specifications and trainings, economic cost, conservation and innovation. Therefore, particular attention should be paid to these problems. Nevertheless, the promotion of thoracic surgery appears promising in the future. PMID:22263074

  12. Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study.

    PubMed

    Catalán, Alfonso; Martínez, Alejandra; Marchesani, Francisco; González, Urcesino

    2016-07-01

    Patients with atrophic edentulous ridges generally have problems with retention, therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to assist in improving retention and stability involves the use of mini-implants. The aim of this study was to evaluate the retention of mandibular overdentures connected to two mini-implants and overall patient satisfaction with them. Seven patients with atrophic mandibular ridges (Type 4D Misch classification), aged 62 to 74 years old were rehabilitated with complete dentures. In each patient, two mini-implants measuring 15 or 13 mm in length and 1.8 mm in diameter were placed. After 15 days, overdentures were connected to the mini-implants with O-ring attachments. In each patient, retention of the overdentures was measured, and a survey of therapeutic satisfaction before and after connection to the mini-implants was administered. Prosthesis retention was measured with a digital dynamometer at 1 month, 6 months, and 2, 3, 5, and 7 years after mini-implant placement. Patient satisfaction was assessed with a survey. Data were analyzed with Student's t-test (satisfaction survey) and the Friedman test (retention measurements and satisfaction survey). The initial retention values (0.34 to 0.63 N without mini-implants) varied significantly (p ≤ 0.050). These values were less than the subsequent measurements of 3.92 to 9.64 N, taken after placement of the mini-implants and connecting them to the dentures. Satisfaction was good to very good over the 7-year observation period. Mucosa and peri-implant bone showed no pathological changes. In this limited sample size clinical study the results indicated that after connecting mandibular overdentures to two mini-implants, patient satisfaction significantly increased and retention significantly improved during the 7-year observation period. © 2015 by the American College of Prosthodontists.

  13. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    PubMed

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P < .05). The stone-free status and complication rates were similar between the two groups (P > .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P < .05). F-URS is less painful than mini-PNL for the treatment of 1- to 2-cm renal stones. However, the stone free rate is similar between the two procedures while mini-PNL is superior in terms of fluoroscopy, operation, hospitalization and return to work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  14. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    PubMed

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  15. Psychometric Evaluation of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    PubMed

    Duncan, Laura; Georgiades, Kathy; Wang, Li; Van Lieshout, Ryan J; MacMillan, Harriet L; Ferro, Mark A; Lipman, Ellen L; Szatmari, Peter; Bennett, Kathryn; Kata, Anna; Janus, Magdalena; Boyle, Michael H

    2017-12-04

    The goals of the study were to examine test-retest reliability, informant agreement and convergent and discriminant validity of nine DSM-IV-TR psychiatric disorders classified by parent and youth versions of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID). Using samples drawn from the general population and child mental health outpatient clinics, 283 youth aged 9 to 18 years and their parents separately completed the MINI-KID with trained lay interviewers on two occasions 7 to 14 days apart. Test-retest reliability estimates based on kappa (κ) went from 0.33 to 0.79 across disorders, samples and informants. Parent-youth agreement on disorders was low (average κ = 0.20). Confirmatory factor analysis provided evidence supporting convergent and discriminant validity. The MINI-KID disorder classifications yielded estimates of test-retest reliability and validity comparable to other standardized diagnostic interviews in both general population and clinic samples. These findings, in addition to the brevity and low administration cost, make the MINI-KID a good candidate for use in epidemiological research and clinical practice. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Major depressive disorder and suicide risk among adult outpatients at several general hospitals in a Chinese Han population

    PubMed Central

    Li, Haiyan; Luo, Xinni; Ke, Xiaoyin; Dai, Qing; Zheng, Wei; Zhang, Chanjuan; Cassidy, Ryan M.; Soares, Jair C.; Zhang, XiangYang

    2017-01-01

    Background Somatic complaints are often the presenting symptoms of major depressive disorder (MDD) in the outpatient context, because this may go unrecognized. It is well understood that MDD carries an increased risk of suicide. This study aimed to identify the risk factors and association with both MDD and suicidality among Han Chinese outpatients. Methods A multicenter study was carried out in 5189 outpatient adults (≥18 years old) in four general hospitals in Guangzhou, China. The 1392 patients who had the Patient Health Questionnaire-9 (PHQ-9) score ≥ 5, indicating depressive symptoms were offered an interview with a psychiatrist by the Mini International Neuropsychiatric Interview (MINI); 819 patients consented and completed the MINI interview. MINI module B was used to assess suicidality. Stepwise binary logistic models were used to estimate the relationship between a significant risk factor and suicide or MDD. According to with or without MDD, the secondary analysis was performed using the logistic regression model for the risk of suicidility. Results The current prevalence of MDD and the one month prevalence of suicidality were 3.7% and 2.3% respectively. The odds ratio of suicidality in women was more than twice that in men (OR = 2.62; 95% CI 1.45–4.76). Other risk factors which were significantly associated with suicidality were: living alone, higher education, self-reported depression, getting psychiatric diagnoses (MDD, anxiety disorders, and bipolar disorders). Significant risk factors for MDD were also noticed, such as comorbid anxiety disorders, self-reported anxiety, insomnia, suicidal ideation. Limitation It’s a cross-sectional study in outpatient clinics using self-report questionnaires. Conclusion This study provides valuable data about the risk factors and association of MDD and suicide risk in adult outpatients in Han Chinese. Those factors allow better the employment of preventative measures. PMID:29016669

  17. The MiniBooNE detector

    NASA Astrophysics Data System (ADS)

    Aguilar-Arevalo, A. A.; Anderson, C. E.; Bartoszek, L. M.; Bazarko, A. O.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Green, C.; Green, J. A.; Hart, T. L.; Hawker, E.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Linden, S. K.; Link, J. M.; Liu, Y.; Liu, Y.; Louis, W. C.; Mahn, K. B. M.; Marsh, W.; Martin, P. S.; McGregor, G.; Metcalf, W.; Meyer, H.-O.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Nelson, R. H.; Nguyen, V. T.; Nienaber, P.; Nowak, J. A.; Ouedraogo, S.; Patterson, R. B.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Sands, W.; Schirato, R.; Schofield, G.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smith, D.; Soderberg, M.; Sorel, M.; Spentzouris, P.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; Van de Water, R.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Zeller, G. P.; Zimmerman, E. D.; MiniBooNE Collaboration

    2009-02-01

    The MiniBooNE neutrino detector was designed and built to look for ν→ν oscillations in the (sin 2θ,Δm) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  18. Quality Assurance Framework for Mini-Grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  19. Designing gondola using satcom services and solar cell energy

    NASA Astrophysics Data System (ADS)

    Cau, M.; Dezen, P.

    Introduction of compact, and lightweight terminals for mobile satellite communication, opens up many opportunities to design new telecommunication systems for balloons. Architecture of this gondola, named Narcisse, is built around a control process unit able to support interface with all Inmarsat services, and Iridium or Thuraya satellite network as well. A first technological gondola was launched from Brazil in February 2001, under a Infra Red Mongolfiere (hot air balloon). This gondola used an Inmarsat terminal C which can support in two ways , store and forward messages at a data rate of 600 bits per second. During the 3 turns around the earth, the system worked well, and demonstrated its ability to handle change over from one geostationary spacecraft to the next, when balloon changes ocean region. Moreover this system provides high telemetry rate (Mbits) or telecommand capability, and greatly increase the performances of the scientific payloads . On the other hand, such types of gondola can be useful to operate long duration flight (days) with large stratospheric balloons, currently limited to range capability of UHF ground station . When line of sight of view is lost, between ground station and gondola, the switch would be made from UHF to the Inmarsat or iridium system to complete the mission. In this case, the TM/TC system has no range or altitude limitation, and the gondola descent trajectory can be followed until the ground improving the localization of landing which will be helpful for recovery operation. So, using a real time duplex mini M Inmarsat terminal, the Narcisse gondola has been operationally involved early 2002 in Archeops project. Launched from Kiruna, Narcisse provided a full duplex 2400bits per second link, all along the flight across Russia. Narcisse has been again involved in march 2003 in Mipas project, using Iridium as a cold redundancy to secure Inmarsat mini M not working at extreme polar regions (latitude more than 80°). During this flight an Inmarsat mini M was also used to provide a scientific telemetry and telecomand channel. A lighter version (15 Kg) of this gondola is currently involved in the Hibiscus project (launch of Infrared montgolfieres from Brazil ). This gondola fitted with the new terminal "Ec track" which taking advantage of better RF budget link offered by Inmarsat spacecraft third generation, requires 50% : launch of hundred pressurized balloons from south pole. The target being to decrease the gondola weight to less than 10 Kg. Expecting a life duration of three months, the energy to heat and power the electronic will be only provided from solar cells and Li Ion secondary battery. Plans for the future : Until now all the terminals we have used with Narcisse have a data rate limited to 2400 bit/s. We are now considering to transmit the data from scientific stratospheric balloons gondolas , by using a high speed terminal (64kbit/s) linked to a mechanically pointed antenna under a pressurized radome.

  20. Study Protocol of MINI SALTEN: a technology-based multi-component intervention in the school environment targeting healthy habits of first grade children and their parents.

    PubMed

    Kovalskys, Irina; Rausch Herscovici, Cecile; Indart Rougier, Paula; De Gregorio, María José; Zonis, Luciana; Orellana, Liliana

    2017-05-06

    MINI SALTEN is a program developed to increase moderate to vigorous physical activity (PA) and improve eating habits at home and school in first grade children. It aims to assess the effects of a technology family-based and PA school-based intervention. The purpose of this manuscript is to describe the protocol design and the MINISALTEN intervention. This is cluster-randomized controlled trial designed to run from July 2015 to November 2016 in 12 public schools of the city of Buenos Aires, matched for socio-demographic characteristics. The intervention is based on two main components: (a) "active breaks" (AB): implemented during school breaks by a PA instructor; (b) "virtual" (V): web-based contents delivered to the families via a multiplatform application. Using a computer generated random sequence participants are allocated to one of four intervention conditions: (AB), (V), (AB + V), and control (C). Outcomes are measured at baseline and 12 months post intervention, and will include data collected from the child and her/his mother/father or guardian. Primary outcome measures are: PA and sedentary behaviour (measured with accelerometers). Secondary outcome measures related are: percentage of kilocalories (kcal) from added sugars, and from total and saturated fats; grams of fruits and vegetables; and number of snacks and kcal coming from their added sugars and total and saturated fats. Family socio-economic level, home environment, and school environment will also be assessed. Statistical analysis is on an intention-to-treat principle. Baseline characteristics are described using summary measures and mixed models (with school as random effect). The effect of the two interventions will be estimated using a generalized mixed linear model with link and distribution selected according to the type of outcome. Included random effects are: child (or mother/father or guardian) accounting for repeated measures; school accounting for cluster induced by school. The most parsimonious model for each outcome will be reported. The False Discovery Rate criterion will be used to correct for multiple testing in non-planned analyses. It is a pioneer assessment of the impact of a technology-based virtual intervention and a school-based PA program, designed to prevent obesity, and involving the parents at public schools of Buenos Aires. Current Controlled Trials ISRCTN58093412 . Registered March 14th, 2016 (retrospectively registered).

  1. Development of a Mini-Freeze Dryer for Material-Sparing Laboratory Processing with Representative Product Temperature History.

    PubMed

    Obeidat, Wasfy M; Sahni, Ekneet; Kessler, William; Pikal, Michael

    2018-02-01

    The goal of the work described in this publication was to evaluate a new, small, material-sparing freeze dryer, denoted as the "mini-freeze dryer or mini-FD", capable of reproducing the product temperature history of larger freeze dryers, thereby facilitating scale-up. The mini-FD wall temperatures can be controlled to mimic loading procedures and dryer process characteristics of larger dryers. The mini-FD is equipped with a tunable diode laser absorption spectroscopy (TDLAS) water vapor mass flow monitor and with other advanced process analytical technology (PAT) sensors. Drying experiments were performed to demonstrate scalability to larger freeze dryers, including the determination of vial heat transfer coefficients, K v . Product temperature histories during K v runs were evaluated and compared with those obtained with a commercial laboratory-scale freeze dryer (LyoStar II) for sucrose and mannitol product formulations. When the mini-FD wall temperature was set at the LyoStar II band temperature (- 20°C) to mimic lab dryer edge vials, edge vial drying in the mini-FD possessed an average K v within 5% of those obtained during drying in the LyoStar II. When the wall temperature of the mini-FD was set equal to the central vial product temperature, edge vials behaved as center vials, possessing a K v value within 5% of those measured in the LyoStar II. During both K v runs and complete product freeze drying runs, the temperature-time profiles for the average edge vials and central vial in the mini-FD agreed well with the average edge and average central vials of the LyoStar II.

  2. Complete overdentures retained by mini implants: A systematic review.

    PubMed

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (<1.5mm). All studies verified an increase in satisfaction and quality of life after rehabilitation treatment with mini dental implants. The present systematic review indicates that the use of mini implants for retaining overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  3. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    NASA Technical Reports Server (NTRS)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  4. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    NASA Technical Reports Server (NTRS)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2014-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini- ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  5. Fracture strength of orthodontic mini-implants

    PubMed Central

    Assad-Loss, Tatiana Feres; Kitahara-Céia, Flávia Mitiko Fernandes; Silveira, Giordani Santos; Elias, Carlos Nelson; Mucha, José Nelson

    2017-01-01

    ABSTRACT Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN). Twenty-five mini-implants were subjected to fracture test by torsion in the neck and the tip, through arbors attached to a Universal Mechanical Testing Machine. The other 25 mini-implants were subjected to insertion torque test into blocks of pork ribs using a torquimeter and contra-angle handpiece mounted in a surgical motor. The shape of the active tip of the mini-implants was evaluated under microscopy. The non-parametric Friedman test and Snedecor’s F in analysis of variance (ANOVA) were used to evaluate the differences between groups. Results: The fracture torque of the neck ranged from 23.45 N.cm (DEN) to 34.82 N.cm (SIN), and of the tip ranged from 9.35 N.cm (CON) to 24.36 N.cm (NEO). Insertion torque values ranged from 6.6 N.cm (RMO) to 10.2 N.cm (NEO). The characteristics that most influenced the results were outer diameter, inner diameter, the ratio between internal and external diameters, and the existence of milling in the apical region of the mini-implant. Conclusions: The fracture torques were different for both the neck and the tip of the five types evaluated. NEO and SIN mini-implants showed the highest resistance to fracture of the neck and tip. The fracture torques of both tip and neck were higher than the torque required to insert mini-implants. PMID:28746487

  6. Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants.

    PubMed

    Espinar-Escalona, Eduardo; Bravo-Gonzalez, Luis-Alberto; Pegueroles, Marta; Gil, Francisco Javier

    2016-06-01

    Self-drilling orthodontic mini-implants can be used as temporary devices for orthodontic treatments. Our main goal was to evaluate surface characteristics, roughness and wettability, of surface modified mini-implants to increase their stability during orthodontic treatment without inducing bone fracture and tissue destruction during unscrewing. Modified mini-implants by acid etching, grit-blasting and its combination were implanted in 20 New Zealand rabbits during 10 weeks. After that, the bone-to-implant (BIC) parameter was determined and the torque during unscrewing was measured. The surface characteristics, roughness and wettability, were also measured, onto modified Ti c.p. discs. Acid-etched mini-implants (R a ≈ 1.7 μm, contact angle (CA) ≈ 66°) significantly improved the bone-to-implant parameter, 26 %, compared to as-machined mini-implants (R a ≈ 0.3 μm, CA ≈ 68°, BIC = 19 %) due to its roughness. Moreover, this surface treatment did not modify torque during unscrewing due to their statistically similar wettability (p > 0.05). Surface treatments with higher roughness and hydrophobicity (R a ≈ 4.5 μm, CA ≈ 74°) lead to a greater BIC and to a higher removal torque during unscrewing, causing bone fracture, compared to as-machined mini-implants. Based on these in vivo findings, we conclude that acid-etching surface treatment can support temporary anchoring of titanium mini-implants. This treatment represents a step forward in the direction of reducing the time prior to mini-implant loading by increasing their stability during orthodontic treatment, without inducing bone fracture and tissue destruction during unscrewing.

  7. Phase 3 study of selected tether applications in space, mid-term review

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Topics addressed include: guidelines for the Space Transportation System (STS) payload deployer design; mini-orbital maneuvering vehicle (MOMV) design: shuttle tether deployer systems (STEDS); cost modeling; tethered platform analysis; fuel savings analysis; and STEDS control simulation.

  8. Using fixed-parameter and random-parameter ordered regression models to identify significant factors that affect the severity of drivers' injuries in vehicle-train collisions.

    PubMed

    Dabbour, Essam; Easa, Said; Haider, Murtaza

    2017-10-01

    This study attempts to identify significant factors that affect the severity of drivers' injuries when colliding with trains at railroad-grade crossings by analyzing the individual-specific heterogeneity related to those factors over a period of 15 years. Both fixed-parameter and random-parameter ordered regression models were used to analyze records of all vehicle-train collisions that occurred in the United States from January 1, 2001 to December 31, 2015. For fixed-parameter ordered models, both probit and negative log-log link functions were used. The latter function accounts for the fact that lower injury severity levels are more probable than higher ones. Separate models were developed for heavy and light-duty vehicles. Higher train and vehicle speeds, female, and young drivers (below the age of 21 years) were found to be consistently associated with higher severity of drivers' injuries for both heavy and light-duty vehicles. Furthermore, favorable weather, light-duty trucks (including pickup trucks, panel trucks, mini-vans, vans, and sports-utility vehicles), and senior drivers (above the age of 65 years) were found be consistently associated with higher severity of drivers' injuries for light-duty vehicles only. All other factors (e.g. air temperature, the type of warning devices, darkness conditions, and highway pavement type) were found to be temporally unstable, which may explain the conflicting findings of previous studies related to those factors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. MINIS: Multipurpose Interactive NASA Information System

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The Multipurpose Interactive NASA Information Systems (MINIS) was developed in response to the need for a data management system capable of operation on several different minicomputer systems. The desired system had to be capable of performing the functions of a LANDSAT photo descriptive data retrieval system while remaining general in terms of other acceptable user definable data bases. The system also had to be capable of performing data base updates and providing user-formatted output reports. The resultant MINI System provides all of these capabilities and several other features to complement the data management system. The MINI System is currently implemented on two minicomputer systems and is in the process of being installed on another minicomputer system. The MINIS is operational on four different data bases.

  10. Next Generation Fast Neutron Detector for Space Exploration (Mini-FND)

    NASA Astrophysics Data System (ADS)

    Hassler, D. M.; Ehresmann, B.

    2018-02-01

    SwRI has developed a miniature Fast Neutron Detector (mini-FND), for use in the Deep Space Gateway, to characterize the neutron albedo radiation. Mini-FND will provide coverage of the biologically relevant neutrons at energies of 500 keV and greater.

  11. A regulatory toolbox of MiniPromoters to drive selective expression in the brain.

    PubMed

    Portales-Casamar, Elodie; Swanson, Douglas J; Liu, Li; de Leeuw, Charles N; Banks, Kathleen G; Ho Sui, Shannan J; Fulton, Debra L; Ali, Johar; Amirabbasi, Mahsa; Arenillas, David J; Babyak, Nazar; Black, Sonia F; Bonaguro, Russell J; Brauer, Erich; Candido, Tara R; Castellarin, Mauro; Chen, Jing; Chen, Ying; Cheng, Jason C Y; Chopra, Vik; Docking, T Roderick; Dreolini, Lisa; D'Souza, Cletus A; Flynn, Erin K; Glenn, Randy; Hatakka, Kristi; Hearty, Taryn G; Imanian, Behzad; Jiang, Steven; Khorasan-zadeh, Shadi; Komljenovic, Ivana; Laprise, Stéphanie; Liao, Nancy Y; Lim, Jonathan S; Lithwick, Stuart; Liu, Flora; Liu, Jun; Lu, Meifen; McConechy, Melissa; McLeod, Andrea J; Milisavljevic, Marko; Mis, Jacek; O'Connor, Katie; Palma, Betty; Palmquist, Diana L; Schmouth, Jean-François; Swanson, Magdalena I; Tam, Bonny; Ticoll, Amy; Turner, Jenna L; Varhol, Richard; Vermeulen, Jenny; Watkins, Russell F; Wilson, Gary; Wong, Bibiana K Y; Wong, Siaw H; Wong, Tony Y T; Yang, George S; Ypsilanti, Athena R; Jones, Steven J M; Holt, Robert A; Goldowitz, Daniel; Wasserman, Wyeth W; Simpson, Elizabeth M

    2010-09-21

    The Pleiades Promoter Project integrates genomewide bioinformatics with large-scale knockin mouse production and histological examination of expression patterns to develop MiniPromoters and related tools designed to study and treat the brain by directed gene expression. Genes with brain expression patterns of interest are subjected to bioinformatic analysis to delineate candidate regulatory regions, which are then incorporated into a panel of compact human MiniPromoters to drive expression to brain regions and cell types of interest. Using single-copy, homologous-recombination "knockins" in embryonic stem cells, each MiniPromoter reporter is integrated immediately 5' of the Hprt locus in the mouse genome. MiniPromoter expression profiles are characterized in differentiation assays of the transgenic cells or in mouse brains following transgenic mouse production. Histological examination of adult brains, eyes, and spinal cords for reporter gene activity is coupled to costaining with cell-type-specific markers to define expression. The publicly available Pleiades MiniPromoter Project is a key resource to facilitate research on brain development and therapies.

  12. NEW CLASS OF VERY HIGH ENERGY {gamma}-RAY EMITTERS: RADIO-DARK MINI SHELLS SURROUNDING ACTIVE GALACTIC NUCLEUS JETS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kino, Motoki; Ito, Hirotaka; Kawakatu, Nozomu

    We explore non-thermal emission from a shocked interstellar medium, which is identified as an expanding shell, driven by a relativistic jet in active galactic nuclei (AGNs). In this work, we particularly focus on parsec-scale size mini shells surrounding mini radio lobes. From the radio to X-ray band, the mini radio lobe emission dominates the faint emission from the mini shell. On the other hand, we find that inverse-Compton (IC) emission from the shell can overwhelm the associated lobe emission at the very high energy (VHE; E > 100 GeV) {gamma}-ray range, because energy densities of synchrotron photons from the lobemore » and/or soft photons from the AGN nucleus are large and IC scattering works effectively. The predicted IC emission from nearby mini shells can be detected with the Cherenkov Telescope Array and they are potentially a new class of VHE {gamma}-ray emitters.« less

  13. Health Effects and Public Health Concerns of Energy Drink Consumption in the United States: A Mini-Review.

    PubMed

    Al-Shaar, Laila; Vercammen, Kelsey; Lu, Chang; Richardson, Scott; Tamez, Martha; Mattei, Josiemer

    2017-01-01

    As energy drink consumption continues to grow worldwide and within the United States, it is important to critically examine the nutritional content and effects on population health of these beverages. This mini-review summarizes the current scientific evidence on health consequences from energy drink consumption, presents relevant public health challenges, and proposes recommendations to mitigate these issues. Emerging evidence has linked energy drink consumption with a number of negative health consequences such as risk-seeking behaviors, poor mental health, adverse cardiovascular effects, and metabolic, renal, or dental conditions. Despite the consistency in evidence, most studies are of cross-sectional design or focus almost exclusively on the effect of caffeine and sugar, failing to address potentially harmful effects of other ingredients. The negative health effects associated with energy drinks (ED) are compounded by a lack of regulatory oversight and aggressive marketing by the industry toward adolescents. Moreover, the rising trend of mixing ED with alcohol presents a new challenge that researchers and public health practitioners must address further. To curb this growing public health issue, policy makers should consider creating a separate regulatory category for ED, setting an evidence-based upper limit on caffeine, restricting sales of ED, and regulating existing ED marketing strategies, especially among children and adolescents.

  14. Effect of dietary macronutrients on aflatoxicosis: a mini-review.

    PubMed

    Nurul Adilah, Zainuddin; Mohd Redzwan, Sabran

    2017-06-01

    Aflatoxin is a toxin produced by Aspergillus species of fungi. The main route of aflatoxin exposure is through the diet. Indeed, long-term aflatoxin exposure is linked to the development of hepatocellular carcinoma (HCC). Aflatoxin causes aflatoxicosis, which can be affected by several factors and is prevalent in many developing Asian and African countries. This mini-review discusses the effects of carbohydrate, fat and protein on aflatoxicosis based on findings from animal and human studies. It was found that high carbohydrate intake enhanced aflatoxicosis occurrence, while low ingestion of carbohydrate with caloric restriction slowed the symptoms associated with aflatoxicosis. Additionally, diets with low protein content worsened the symptoms related to HCC due to aflatoxin exposure. Nevertheless, a study reported that a high-protein diet favored detoxification of aflatoxin in vivo. There were also conflicting results on the influence of dietary fat, as high ingestion of fat enhanced aflatoxicosis development as compared with a low-fat diet. Moreover, the type of fat also plays a significant role in influencing aflatoxin toxicity. In regard to food safety, understanding the influence of macronutrients toward the progression of aflatoxicosis can improve preventive measures against human and animal exposure to aflatoxin. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  15. Colonic luminal microbiota and bacterial metabolite composition in pregnant Huanjiang mini-pigs: effects of food composition at different times of pregnancy

    PubMed Central

    Kong, Xiang-feng; Ji, Yu-jiao; Li, Hua-wei; Zhu, Qian; Blachier, F.; Geng, Mei-mei; Chen, Wen; Yin, Yu-long

    2016-01-01

    The gut harbours diverse and complex microbiota, which influence body health including nutrient metabolism, immune development, and protection from pathogens. Pregnancy is associated with immune and metabolic changes that might be related to microbiota compositional dynamics. We therefore investigated the colonic luminal bacteria community in Huanjiang mini-pigs fed diets with different nutrient levels from the first to third trimester of pregnancy. The concentrations of intestinal metabolites including short-chain fat acids, NH3-N, indole, skatole, and bioamines were also determined. We found that the colonic bacteria species richness estimators (Chao1 and ACE) decreased with increased gestational age. The dominant phyla identified were Firmicutes and Bacteroidetes; the dominant genera were Lactobacillus, Treponema, Ruminococcus, Clostridium, and Prevotella. In addition, microbiota displayed spatial and temporal heterogeneity in composition, diversity, and species abundance in different colonic segments from the first to third trimester of pregnancy. Furthermore, the bacterial metabolites also changed according to the diet used and the pregnancy stage. These findings suggest that colonic bacteria richness decreased as gestational age increased, and that the higher nutrient level diet increased the production of metabolites related to nitrogen metabolism. However, although the higher nutrient diet was associated with pregnancy syndrome, causal links remain to be determined. PMID:27917879

  16. The mini-cog: a cognitive 'vital signs' measure for dementia screening in multi-lingual elderly.

    PubMed

    Borson, S; Scanlan, J; Brush, M; Vitaliano, P; Dokmak, A

    2000-11-01

    The Mini-Cog, a composite of three-item recall and clock drawing, was developed as a brief test for discriminating demented from non-demented persons in a community sample of culturally, linguistically, and educationally heterogeneous older adults. All 129 who met criteria for probable dementia based on informant interviews and 120 with no history of cognitive decline were included; 124 were non-English speakers. Sensitivity, specificity, and diagnostic value of the Mini-Cog were compared with those of the Mini-Mental State Exam (MMSE) and Cognitive Abilities Screening Instrument (CASI). The Mini-Cog had the highest sensitivity (99%) and correctly classified the greatest percentage (96%) of subjects. Moreover, its diagnostic value was not influenced by education or language, while that of the CASI was adversely influenced by low education, and both education and language compromised the diagnostic value of the MMSE. Administration time for the Mini-Cog was 3 minutes vs 7 minutes for the MMSE. The Mini-Cog required minimal language interpretation and training to administer, and no test forms of scoring modifications were needed to compensate for the extensive linguistic and educational heterogeneity of the sample. Validation in clinical and population-based samples is warranted, as its brevity and ease of administration suggest that the Mini-Cog might be readily incorporated into general practice and senior care settings as a routine 'cognitive vital signs' measure. Copyright 2000 John Wiley & Sons, Ltd.

  17. Diagnostic Accuracy and Cost-Effectiveness of Alternative Methods for Detection of Soil-Transmitted Helminths in a Post-Treatment Setting in Western Kenya

    PubMed Central

    Kepha, Stella; Kihara, Jimmy H.; Njenga, Sammy M.; Pullan, Rachel L.; Brooker, Simon J.

    2014-01-01

    Objectives This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Methods Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Results Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. Conclusions The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings. PMID:24810593

  18. Diagnostic accuracy and cost-effectiveness of alternative methods for detection of soil-transmitted helminths in a post-treatment setting in western Kenya.

    PubMed

    Assefa, Liya M; Crellen, Thomas; Kepha, Stella; Kihara, Jimmy H; Njenga, Sammy M; Pullan, Rachel L; Brooker, Simon J

    2014-05-01

    This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings.

  19. Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery

    PubMed Central

    Wang, Xianliang; Li, Yupeng; Zhang, Xiaodong; Li, Heng; Miyazaki, Koichi; Fujimoto, Rintaro; Akiyama, Hiroshi; Poenisch, Falk; Sahoo, Narayan; Grosshans, David; Gunn, Brandon; Frank, Steven Jay; Wang, Pei; Lang, Jinyi; Zhu, Xiaorong Ronald

    2017-01-01

    A mini-ridge filter is often used to widen the Bragg peak in the longitudinal direction at low energies but not high energies. To facilitate the clinical use of a mini-ridge filter, we performed a planning study for the feasibility of a mini-ridge filter as an integral part of the synchrotron nozzle (IMRF). Dose models with and without IMRF were commissioned in a commercial Treatment planning system (TPS). Dosimetric characteristics in a homogenous water phantom were compared between plans with and without IMRF for a fixed spread-out Bragg peak width of 4 cm with distal ranges varying from 8 to 30 g/cm2. Six clinical cases were then used to compare the plan quality between plans. The delivery efficiency was also compared between plans in both the phantom and the clinical cases. The Bragg peak width was increased by 0.18 cm at the lowest energy and by only about 0.04 cm at the highest energy. The IMRF increased the spot size (σ) by up to 0.1 cm at the lowest energy and by only 0.02 cm at the highest energy. For the phantom, the IMRF negligibly affected dose at high energies but increased the lateral penumbra by up to 0.12 cm and the distal penumbra by up to 0.06 cm at low energies. For the clinical cases, the IMRF slightly increased dose to the organs at risk. However, the beam delivery time was reduced from 18.5% to 47.1% for the lung, brain, scalp, and head and neck cases, and dose uniformities of target were improved up to 2.9% for these cases owing to the reduced minimum monitor unit effect. In conclusion, integrating a mini-ridge filter into a synchrotron nozzle is feasible for improving treatment efficiency without significantly sacrificing the plan quality. PMID:29236051

  20. Mini-Lectures: A Taster to Engage the Audience for the Main Event

    ERIC Educational Resources Information Center

    Ingram, Matthew J.; Crane, Simeon; Mokree, Alan; Curdy, Marion E.; Patel, Bhavik A.

    2017-01-01

    This article explores the use of pre-recorded video mini-lectures to support and enhance traditional face-to-face lectures for undergraduate students. Mini-lectures guide students through key concepts so that they can understand and assimilate key content before attending lectures.

  1. Sean Esterly | NREL

    Science.gov Websites

    , micro and mini-grid policies and regulations, and international clean energy policy analysis. He has technologies, such as micro- and mini-grids. Strategic energy planning, focusing on both renewable and energy Considerations and Good Practices, NREL Technical Report (2015) Quality Assurance Framework for Mini-Grids, NREL

  2. Ganymede's magnetosphere: Magnetometer overview

    NASA Astrophysics Data System (ADS)

    Kivelson, M. G.; Warnecke, J.; Bennett, L.; Joy, S.; Khurana, K. K.; Linker, J. A.; Russell, C. T.; Walker, R. J.; Polanskey, C.

    1998-09-01

    Ganymede presents a unique example of an internally magnetized moon whose intrinsic magnetic field excludes the plasma present at its orbit, thereby forming a magnetospheric cavity. We describe some of the properties of this mini-magnetosphere, embedded in a sub-Alfvénic flow and formed within a planetary magnetosphere. A vacuum superposition model (obtained by adding the internal field of Ganymede to the field imposed by Jupiter) organizes the data acquired by the Galileo magnetometer on four close passes in a useful, intuitive fashion. The last field line that links to Ganymede at both ends extends to ~2 Ganymede radii, and the transverse scale of the magnetosphere is ~5.5 Ganymede radii. Departures from this simple model arise from currents flowing in the Alfvén wings and elsewhere on the magnetopause. The four passes give different cuts through the magnetosphere from which we develop a geometric model for the magnetopause surface as a function of the System III location of Ganymede. On one of the passes, Ganymede was located near the center of Jupiter's plasma disk. For this pass we identify probable Kelvin-Helmholtz surface waves on the magnetopause. After entering the relatively low-latitude upstream magnetosphere, Galileo apparently penetrated the region of closed field lines (ones that link to Ganymede at both ends), where we identify predominantly transverse fluctuations at frequencies reasonable for field line resonances. We argue that magnetic field measurements, when combined with flow measurements, show that reconnection is extremely efficient. Downstream reconnection, consequently, may account for heated plasma observed in a distant crossing of Ganymede's wake. We note some of the ways in which Ganymede's unusual magnetosphere corresponds to familiar planetary magnetospheres (viz., the magnetospheric topology and an electron ring current). We also comment on some of the ways in which it differs from familiar planetary magnetospheres (viz., relative stability and predictability of upstream plasma and field conditions, absence of a magnetotail plasma sheet and of a plasmasphere, and probable instability of the ring current).

  3. Corn-on-a-chip: Mini-channel Device for Corn Root Growth

    NASA Astrophysics Data System (ADS)

    Kreis, Kevin; Ryu, Sangjin

    2015-11-01

    Plant growth heavily relies on interactions between the root and the soil environment, but it is impossible to observe such interactions because of opaqueness of soil. Microfluidics has been successfully utilized to monitor the root growth behaviors of Arabidopsis. In this study we have chosen Maize as a model plant because of its economic significance, and aim to develop transparent mini-channel devices accommodating the root growth of corn seedlings in a controlled environment. To mimic aspects of the soil environment, we try to impose concentration gradients of key chemical ions to the growing root using the device, and to investigate how the root responds to the applied stimuli. We acknowledge support from NASA Nebraska Space Grant Fellowship.

  4. Search for sterile neutrino oscillations in muon neutrino disappearance at MINOS/MINOS+

    NASA Astrophysics Data System (ADS)

    Todd, Jacob; Minos+ Collaboration

    2017-01-01

    A wide variety of neutrino oscillation phenomena are well-described by the standard three-flavour neutrino model, but some anomalies exist. The LSND and MiniBooNE experiments have measured electron antineutrino appearance in excess of standard oscillation predictions, which points to the possibility of a sterile neutrino with higher mass than the presently known states. MINOS, a two-detector, long-baseline neutrino oscillation experiment, was optimized for the measurement of muon neutrino disappearance in the NuMI neutrino beam. A sterile neutrino responsible for the LSND and MiniBooNE excesses would cause distortions in the charged current and neutral current MINOS spectra, which permits the search for sterile neutrinos at MINOS. In close collaboration with the Daya Bay reactor neutrino experiment, MINOS has placed strong constraints on the sterile neutrino parameter space for a model with one additional sterile neutrino. Further, the extension of data collection with MINOS+, which samples the NuMI beam in a medium energy configuration, markedly increases the sensitivity of the combined MINOS and MINOS+ sample to a 3+1-flavour sterile neutrino model.

  5. CoMiniGut—a small volume in vitro colon model for the screening of gut microbial fermentation processes

    PubMed Central

    Khakimov, Bekzod; Nielsen, Sebastian; Sørensen, Helena; van den Berg, Frans; Nielsen, Dennis Sandris

    2018-01-01

    Driven by the growing recognition of the influence of the gut microbiota (GM) on human health and disease, there is a rapidly increasing interest in understanding how dietary components, pharmaceuticals and pre- and probiotics influence GM. In vitro colon models represent an attractive tool for this purpose. With the dual objective of facilitating the investigation of rare and expensive compounds, as well as an increased throughput, we have developed a prototype in vitro parallel gut microbial fermentation screening tool with a working volume of only 5 ml consisting of five parallel reactor units that can be expanded with multiples of five to increase throughput. This allows e.g., the investigation of interpersonal variations in gut microbial dynamics and the acquisition of larger data sets with enhanced statistical inference. The functionality of the in vitro colon model, Copenhagen MiniGut (CoMiniGut) was first demonstrated in experiments with two common prebiotics using the oligosaccharide inulin and the disaccharide lactulose at 1% (w/v). We then investigated fermentation of the scarce and expensive human milk oligosaccharides (HMOs) 3-Fucosyllactose, 3-Sialyllactose, 6-Sialyllactose and the more common Fructooligosaccharide in fermentations with infant gut microbial communities. Investigations of microbial community composition dynamics in the CoMiniGut reactors by MiSeq-based 16S rRNA gene amplicon high throughput sequencing showed excellent experimental reproducibility and allowed us to extract significant differences in gut microbial composition after 24 h of fermentation for all investigated substrates and fecal donors. Furthermore, short chain fatty acids (SCFAs) were quantified for all treatments and donors. Fermentations with inulin and lactulose showed that inulin leads to a microbiota dominated by obligate anaerobes, with high relative abundance of Bacteroidetes, while the more easily fermented lactulose leads to higher relative abundance of Proteobacteria. The subsequent study on the influence of HMOs on two infant GM communities, revealed the strongest bifidogenic effect for 3′SL for both infants. Inter-individual differences of infant GM, especially with regards to the occurrence of Bacteroidetes and differences in bifidobacterial species composition, correlated with varying degrees of HMO utilization foremost of 6′SL and 3′FL, indicating species and strain related differences in HMO utilization which was also reflected in SCFAs concentrations, with 3′SL and 6′SL resulting in significantly higher butyrate production compared to 3′FL. In conclusion, the increased throughput of CoMiniGut strengthens experimental conclusions through elimination of statistical interferences originating from low number of repetitions. Its small working volume moreover allows the investigation of rare and expensive bioactives. PMID:29372119

  6. W14_greenhousegas Multi-scale Atmospheric Modeling of Green House Gas Dispersion in Complex Terrain: Controlled Release Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costigan, Keeley Rochelle; Sauer, Jeremy A.; Travis, Bryan J.

    2016-07-18

    This slide deals with the following: Affordable artificial neural network and mini-sensor system to locate and quantify methane leaks on a well pad; ARPA-e project schematic for monitoring methane leaks

  7. Predictors of Rater Bias in the Assessment of Social-Emotional Competence

    ERIC Educational Resources Information Center

    Shapiro, Valerie B.; Kim, B. K. Elizabeth; Accomazzo, Sarah; Roscoe, Joe N.

    2016-01-01

    "The Devereux Student Strengths Assessment Mini" (DESSA-Mini) (LeBuffe, Shapiro, & Naglieri, 2014) efficiently monitors the growth of Social-Emotional Competence (SEC) in the routine implementation of Social Emotional Learning programs. The DESSA-Mini is used to assess approximately half a million children around the world. Since…

  8. Teaching Economics in the Mini-Economy.

    ERIC Educational Resources Information Center

    Indiana State Dept. of Education, Indianapolis.

    This booklet produced by the State of Indiana introduces elementary teachers to economic concepts appropriate to the elementary curriculum and explains how to use mini-economy activities to teach these concepts. Chapter 1 describes how the mini-economy works, while chapter 2 introduces basic economic vocabulary and discusses market economy. Ideas…

  9. Partners | Integrated Energy Solutions | NREL

    Science.gov Websites

    Develops Off-Grid Energy Access through Quality Assurance Framework for Mini-Grids NREL has teamed with the Africa to develop a Quality Assurance Framework for isolated mini-grids. NREL Enhances Energy Resiliency Partnership Develops Off-Grid Energy Access through Quality Assurance Framework for Mini-Grids NREL has teamed

  10. NREL Partnership Develops Off-Grid Energy Access through Quality Assurance

    Science.gov Websites

    Framework for Mini-Grids | Integrated Energy Solutions | NREL Partnership Develops Off-Grid Energy Access through Quality Assurance Framework for Mini-Grids NREL Partnership Develops Off-Grid Energy Access through Quality Assurance Framework for Mini-Grids NREL has teamed with the Global Lighting

  11. NREL: International Activities - Energy Access

    Science.gov Websites

    experience with off-grid solutions to support mini and microgrid projects, policies, and programs that are prohibitively expensive. Investment interest in mini and microgrids for energy access has been growing among Quality Assurance Framework (QAF) for mini-grids was developed to address the root challenges to providing

  12. Mini-clusters

    NASA Technical Reports Server (NTRS)

    Chinellato, J. A.; Dobrigkeit, C.; Bellandifilho, J.; Lattes, C. M. G.; Menon, M. J.; Navia, C. E.; Pamilaju, A.; Sawayanagi, K.; Shibuya, E. H.; Turtelli, A., Jr.

    1985-01-01

    Experimental results of mini-clusters observed in Chacaltaya emulsion chamber no.19 are summarized. The study was made on 54 single core shower upper and 91 shower clusters of E(gamma) 10 TeV from 30 families which are visible energy greater than 80 TeV and penetrate through both upper and lower detectors of the two-story chamber. The association of hadrons in mini-cluster is made clear from their penetrative nature and microscopic observation of shower continuation in lower chamber. Small P sub t (gamma) of hadrons in mini-clusters remained in puzzle.

  13. Time domain modal identification/estimation of the mini-mast testbed

    NASA Technical Reports Server (NTRS)

    Roemer, Michael J.; Mook, D. Joseph

    1991-01-01

    The Mini-Mast is a 20 meter long 3-dimensional, deployable/retractable truss structure designed to imitate future trusses in space. Presented here are results from a robust (with respect to measurement noise sensitivity), time domain, modal identification technique for identifying the modal properties of the Mini-Mast structure even in the face of noisy environments. Three testing/analysis procedures are considered: sinusoidal excitation near resonant frequencies of the Mini-Mast, frequency response function averaging of several modal tests, and random input excitation with a free response period.

  14. Analysis, design, fabrication and testing of the mini-Brayton rotating unit (Mini-BRU). Volume 1: Text and tables

    NASA Technical Reports Server (NTRS)

    Dobler, F. X.

    1978-01-01

    A 500 to 2100 watt power output Mini-Brayton Rotating Unit (Mini-BRU)was analyzed, designed, fabricated and tested. Performance and test data for the various components is included. Components tested include the 2.12 in. diameter compressor, the 2.86 in. diameter turbine, the Rice alternator and the cantilevered foil-type journal and thrust bearings. Also included are results on the fabrication of a C-103 turbine plenum/nozzle assembly and on offgassing of the organic materials in the alternator stator.

  15. Systemic levels of metallic ions released from orthodontic mini-implants.

    PubMed

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  16. Accuracy of mini peak flow meters in indicating changes in lung function in children with asthma.

    PubMed Central

    Sly, P. D.; Cahill, P.; Willet, K.; Burton, P.

    1994-01-01

    OBJECTIVE--To assess whether mini flow meters used to measure peak expiratory flow can track changes in lung function and indicate clinically important changes. DESIGN--Comparison of measurements with a spirometer and different brands of mini flow meter; the meters were allocated to subjects haphazardly. SUBJECTS--12 boys with asthma aged 11 to 17 attending boarding school. MAIN OUTCOME MEASURES--Peak expiratory flow measured twice daily for three months with a spirometer and at least one of four brands of mini flow meter. RESULTS--The relation between changes in lung function measured with the spirometer and those measured with the mini flow meters was generally poor. In all, 26 episodes (range 1-3 in an individual child) of clinically important deterioration in lung function were detected from the records obtained with the spirometer. One mini flow meter detected six of 19 episodes, one detected six of 15, one detected six of 18, and one detected three of 21. CONCLUSIONS--Not only are the absolute values of peak expiratory flow obtained with mini flow meters inaccurate but the clinical message may also be incorrect. These findings do not imply that home monitoring of peak expiratory flow has no place in the management of childhood asthma but that the values obtained should be interpreted cautiously. PMID:8148680

  17. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    PubMed

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  18. Spurious RF signals emitted by mini-UAVs

    NASA Astrophysics Data System (ADS)

    Schleijpen, Ric (H. M. A.); Voogt, Vincent; Zwamborn, Peter; van den Oever, Jaap

    2016-10-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to the sensor community. The detection, classification and identification chain can take advantage of different sensor technologies. Apart from the signatures used by radar and electro-optical sensor systems, the UAV also emits RF signals. These RF signatures can be split in intentional signals for communication with the operator and un-intentional RF signals emitted by the UAV. These unintentional or spurious RF emissions are very weak but could be used to discriminate potential UAV detections from false alarms. The goal of this research was to assess the potential of exploiting spurious emissions in the classification and identification chain of mini-UAVs. It was already known that spurious signals are very weak, but the focus was on the question whether the emission pattern could be correlated to the behaviour of the UAV. In this paper experimental examples of spurious RF emission for different types of mini-UAVs and their correlation with the electronic circuits in the UAVs will be shown

  19. A DNA Mini-Barcoding System for Authentication of Processed Fish Products.

    PubMed

    Shokralla, Shadi; Hellberg, Rosalee S; Handy, Sara M; King, Ian; Hajibabaei, Mehrdad

    2015-10-30

    Species substitution is a form of seafood fraud for the purpose of economic gain. DNA barcoding utilizes species-specific DNA sequence information for specimen identification. Previous work has established the usability of short DNA sequences-mini-barcodes-for identification of specimens harboring degraded DNA. This study aims at establishing a DNA mini-barcoding system for all fish species commonly used in processed fish products in North America. Six mini-barcode primer pairs targeting short (127-314 bp) fragments of the cytochrome c oxidase I (CO1) DNA barcode region were developed by examining over 8,000 DNA barcodes from species in the U.S. Food and Drug Administration (FDA) Seafood List. The mini-barcode primer pairs were then tested against 44 processed fish products representing a range of species and product types. Of the 44 products, 41 (93.2%) could be identified at the species or genus level. The greatest mini-barcoding success rate found with an individual primer pair was 88.6% compared to 20.5% success rate achieved by the full-length DNA barcode primers. Overall, this study presents a mini-barcoding system that can be used to identify a wide range of fish species in commercial products and may be utilized in high throughput DNA sequencing for authentication of heavily processed fish products.

  20. Mini-titins in striated and smooth molluscan muscles: structure, location and immunological crossreactivity.

    PubMed

    Vibert, P; Edelstein, S M; Castellani, L; Elliott, B W

    1993-12-01

    Invertebrate mini-titins are members of a class of myosin-binding proteins belonging to the immunoglobulin superfamily that may have structural and/or regulatory properties. We have isolated mini-titins from three molluscan sources: the striated and smooth adductor muscles of the scallop, and the smooth catch muscles of the mussel. Electron microscopy reveals flexible rod-like molecules about 0.2 micron long and 30 A wide with a distinctive polarity. Antibodies to scallop mini-titin label the A-band and especially the A/I junction of scallop striated muscle myofibrils by indirect immunofluorescence and immuno-electron microscopy. This antibody crossreacts with mini-titins in scallop smooth and Mytilus catch muscles, as well as with proteins in striated muscles from Limulus, Lethocerus (asynchronous flight muscle), and crayfish. It labels the A/I junction (I-region in Lethocerus) in these striated muscles as well as in chicken skeletal muscle. Antibodies to the repetitive immunoglobulin-like regions and also to the kinase domain of nematode twitchin crossreact with scallop mini-titin and label the A-band of scallop myofibrils. Electron microscopy of single molecules shows that antibodies to twitchin kinase bind to scallop mini-titin near one end of the molecule, suggesting how the scallop structure might be aligned with the sequence of nematode twitchin.

  1. Replacing the AMOR with the miniDOAS in the ammonia monitoring network in the Netherlands

    NASA Astrophysics Data System (ADS)

    Berkhout, Augustinus J. C.; Swart, Daan P. J.; Volten, Hester; Gast, Lou F. L.; Haaima, Marty; Verboom, Hans; Stefess, Guus; Hafkenscheid, Theo; Hoogerbrugge, Ronald

    2017-11-01

    In this paper we present the continued development of the miniDOAS, an active differential optical absorption spectroscopy (DOAS) instrument used to measure ammonia concentrations in ambient air. The miniDOAS has been adapted for use in the Dutch National Air Quality Monitoring Network. The miniDOAS replaces the life-expired continuous-flow denuder ammonia monitor (AMOR). From September 2014 to December 2015, both instruments measured in parallel before the change from AMOR to miniDOAS was made. The instruments were deployed at six monitoring stations throughout the Netherlands. We report on the results of this intercomparison. Both instruments show a good uptime of ca. 90 %, adequate for an automatic monitoring network. Although both instruments produce 1 min values of ammonia concentrations, a direct comparison on short timescales such as minutes or hours does not give meaningful results because the AMOR response to changing ammonia concentrations is slow. Comparisons between daily and monthly values show good agreement. For monthly averages, we find a small average offset of 0.65 ± 0.28 µg m-3 and a slope of 1.034 ± 0.028, with the miniDOAS measuring slightly higher than the AMOR. The fast time resolution of the miniDOAS makes the instrument suitable not only for monitoring but also for process studies.

  2. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics.

    PubMed

    El-Say, Khalid M; Ahmed, Tarek A; Abdelbary, Maged F; Ali, Bahaa E; Aljaeid, Bader M; Zidan, Ahmed S

    2015-12-01

    This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets) as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1), swelling pressure of the superdisintegrant (X2), and the surface area of Aerosil as a glidant (X3). Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for pre- and post-compression characteristics. The prepared OD-mini-tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2) and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  3. Quantifying Motor Experience in the Infant Brain: EEG Power, Coherence, and Mu Desynchronization

    PubMed Central

    Gonzalez, Sandy L.; Reeb-Sutherland, Bethany C.; Nelson, Eliza L.

    2016-01-01

    The emergence of new motor skills, such as reaching and walking, dramatically changes how infants engage with the world socially and cognitively. Several examples of how motor experience can cascade into cognitive and social development have been documented, yet a significant knowledge gap remains in our understanding of whether these observed behavioral changes are accompanied by underlying neural changes. We propose that electroencephalography (EEG) measures such as power, coherence, and mu desynchronization are optimal tools to quantify motor experience in the infant brain. In this mini-review, we will summarize existing infant research that has separately assessed the relation between motor, cognitive, or social development with coherence, power, or mu desynchronization. We will discuss how the reviewed neural changes seen in seemingly separate developmental domains may be linked based on existing behavioral evidence. We will further propose that power, coherence, and mu desynchronization be used in research exploring the links between motor experience and cognitive and social development. PMID:26925022

  4. Combating Terrorism Technical Support Office. 2008 Review

    DTIC Science & Technology

    2009-01-15

    threat object displayed at the operator control unit of the robotic platform. Remote Utility Conversion Kit The Remote Utility Conversion Kit (RUCK) is a...three- dimensional and isometric simulations and games. Develop crowd models, adversarial behavior models, network-based simulations, mini-simulations...Craft-Littoral The modular unmanned surface craft-littoral ( MUSCL ) is a spin- off of EOD/LIC’s Unmanned Reconnaissance Observation Craft, developed

  5. Identification of measurement differences between English and Spanish language versions of the Mini-Mental State Examination. Detecting differential item functioning using MIMIC modeling.

    PubMed

    Jones, Richard N

    2006-11-01

    Knowledge of the extent to which measurement of adult cognitive functioning differs between Spanish and English language administrations of the Mini-Mental State Examination (MMSE) is critical for inclusive, representative, and valid research of older adults in the United States. We sought to demonstrate the use of an item response theory (IRT) based structural equation model, that is, the MIMIC model (multiple indicators, multiple causes), to evaluate MMSE responses for evidence of differential item functioning (DIF) attributable to language of administration. We studied participants in a dementia case registry study (n = 1546), 42% of whom were examined with the Spanish language MMSE. Twelve of 21 items were identified as having significant uniform DIF. The 4 most discrepant included orientation to season, orientation to state, repeat phrase, and follow command. DIF accounted for two-thirds of the observed difference in underlying level of cognitive functioning between Spanish- and English-language administration groups. Failing to account for measurement differences may lead to spurious inferences regarding language group differences in level of underlying level of cognitive functioning. The MIMIC model can be used to detect and adjust for such measurement differences in substantive research.

  6. Relativistic MHD simulations of collision-induced magnetic dissipation in poynting-flux-dominated jets/outflows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Wei; Li, Hui; Zhang, Bing

    We perform 3D relativistic ideal MHD simulations to study the collisions between high-σ (Poynting- ux-dominated) blobs which contain both poloidal and toroidal magnetic field components. This is meant to mimic the interactions inside a highly variable Poynting- ux-dominated jet. We discover a significant electromagnetic field (EMF) energy dissipation with an Alfvenic rate with the efficiency around 35%. Detailed analyses show that this dissipation is mostly facilitated by the collision-induced magnetic reconnection. Additional resolution and parameter studies show a robust result that the relative EMF energy dissipation efficiency is nearly independent of the numerical resolution or most physical parameters in themore » relevant parameter range. The reconnection outflows in our simulation can potentially form the multi-orientation relativistic mini-jets as needed for several analytical models. We also find a linear relationship between the σ values before and after the major EMF energy dissipation process. In conclusion, our results give support to the proposed astrophysical models that invoke signi cant magnetic energy dissipation in Poynting- ux-dominated jets, such as the internal collision-induced magnetic reconnection and turbulence (ICMART) model for GRBs, and reconnection triggered mini-jets model for AGNs.« less

  7. Relativistic MHD simulations of collision-induced magnetic dissipation in poynting-flux-dominated jets/outflows

    DOE PAGES

    Deng, Wei; Li, Hui; Zhang, Bing; ...

    2015-05-29

    We perform 3D relativistic ideal MHD simulations to study the collisions between high-σ (Poynting- ux-dominated) blobs which contain both poloidal and toroidal magnetic field components. This is meant to mimic the interactions inside a highly variable Poynting- ux-dominated jet. We discover a significant electromagnetic field (EMF) energy dissipation with an Alfvenic rate with the efficiency around 35%. Detailed analyses show that this dissipation is mostly facilitated by the collision-induced magnetic reconnection. Additional resolution and parameter studies show a robust result that the relative EMF energy dissipation efficiency is nearly independent of the numerical resolution or most physical parameters in themore » relevant parameter range. The reconnection outflows in our simulation can potentially form the multi-orientation relativistic mini-jets as needed for several analytical models. We also find a linear relationship between the σ values before and after the major EMF energy dissipation process. In conclusion, our results give support to the proposed astrophysical models that invoke signi cant magnetic energy dissipation in Poynting- ux-dominated jets, such as the internal collision-induced magnetic reconnection and turbulence (ICMART) model for GRBs, and reconnection triggered mini-jets model for AGNs.« less

  8. Collection of Culicoides spp. with four light trap models during different seasons in the Balearic Islands.

    PubMed

    del Río, R; Monerris, M; Miquel, M; Borràs, D; Calvete, C; Estrada, R; Lucientes, J; Miranda, M A

    2013-07-01

    Bluetongue (BT) is a viral disease that affects ruminants, being especially pathogenic in certain breeds of sheep. Its viral agent (bluetongue virus; BTV) is transmitted by several species of Culicoides biting midges (Diptera: Ceratopogonidae). Different models of suction light traps are being used in a number of countries for the collection of BTV vector species. To determine the relative effectiveness of different light traps under field conditions, four traps (Onderstepoort, Mini-CDC, Rieb and Pirbright) were compared. These traps were rotated between four sites on a cattle farm in Mallorca (Balearic Islands, Spain) for several non-consecutive nights. Results showed remarkable disparities in the efficacy of the traps for the collection of Culicoides midges. The highest number of midges collected in the Onderstepoort trap (x¯±SD=62±94.2) was not significantly different from that collected in the Mini-CDC (x¯±SD=58±139.2). The Rieb trap collected the lowest number of midges (x¯±SD=3±4.0). Significantly higher mean numbers of midges were collected in the Onderstepoort than in either the Pirbright (P=0.002) or Rieb traps (P=0.008). There were also differences in the Culicoides species composition as determine with the various traps. These results indicate that the Onderstepoort or Mini-CDC traps will be more effective than either the Rieb or Pirbright traps for the collection of large numbers of Culicoides midges. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Experimental infection with the Toxoplasma gondii ME-49 strain in the Brazilian BR-1 mini pig is a suitable animal model for human toxoplasmosis.

    PubMed

    Miranda, Farlen José Bebber; Souza, Diogo Benchimol de; Frazão-Teixeira, Edwards; Oliveira, Fábio Conceição de; Melo, João Cardoso de; Mariano, Carlos Magno Anselmo; Albernaz, Antonio Peixoto; Carvalho, Eulógio Carlos Queiróz de; Oliveira, Francisco Carlos Rodrigues de; Souza, Wanderley de; DaMatta, Renato Augusto

    2015-02-01

    Toxoplasma gondii causes toxoplasmosis, a worldwide disease. Experimentation with pigs is necessary for the development of new therapeutic approaches to human diseases. BR-1 mini pigs were intramuscularly infected with T. gondii with tachyzoites (RH strain) or orally infected with cysts (ME-49 strain). Haematology and serum biochemistry were analysed and buffy coat cells were inoculated in mice to determine tachyzoite circulation. No alterations were observed in erythrocyte and platelet values; however, band neutrophils increased seven days after infection with ME-49. Serology of the mice inoculated with pig blood leucocytes revealed circulating ME-49 or RH strain tachyzoites in the pigs' peripheral blood at two and seven or nine days post-infection. The tachyzoites were also directly observed in blood smears from the infected pigs outside and inside leucocytes for longer periods. Alanine-aminotransferase was high at days 21 and 32 in the RH infected pigs. After 90 days, the pigs were euthanised and their tissue samples were processed and inoculated into mice. The mice serology revealed the presence of parasites in the hearts, ileums and mesenteric lymph nodes of the pigs. Additionally, cysts in the mice were only observed after pig heart tissue inoculation. The infected pigs presented similar human outcomes with relatively low pathogenicity and the BR-1 mini pig model infected with ME-49 is suitable to monitor experimental toxoplasmosis.

  10. Experimental infection with the Toxoplasma gondii ME-49 strain in the Brazilian BR-1 mini pig is a suitable animal model for human toxoplasmosis

    PubMed Central

    Miranda, Farlen José Bebber; de Souza, Diogo Benchimol; Frazão-Teixeira, Edwards; de Oliveira, Fábio Conceição; de Melo, João Cardoso; Mariano, Carlos Magno Anselmo; Albernaz, Antonio Peixoto; de Carvalho, Eulógio Carlos Queiróz; de Oliveira, Francisco Carlos Rodrigues; de Souza, Wanderley; DaMatta, Renato Augusto

    2015-01-01

    Toxoplasma gondii causes toxoplasmosis, a worldwide disease. Experimentation with pigs is necessary for the development of new therapeutic approaches to human diseases. BR-1 mini pigs were intramuscularly infected with T. gondii with tachyzoites (RH strain) or orally infected with cysts (ME-49 strain). Haematology and serum biochemistry were analysed and buffy coat cells were inoculated in mice to determine tachyzoite circulation. No alterations were observed in erythrocyte and platelet values; however, band neutrophils increased seven days after infection with ME-49. Serology of the mice inoculated with pig blood leucocytes revealed circulating ME-49 or RH strain tachyzoites in the pigs' peripheral blood at two and seven or nine days post-infection. The tachyzoites were also directly observed in blood smears from the infected pigs outside and inside leucocytes for longer periods. Alanine-aminotransferase was high at days 21 and 32 in the RH infected pigs. After 90 days, the pigs were euthanised and their tissue samples were processed and inoculated into mice. The mice serology revealed the presence of parasites in the hearts, ileums and mesenteric lymph nodes of the pigs. Additionally, cysts in the mice were only observed after pig heart tissue inoculation. The infected pigs presented similar human outcomes with relatively low pathogenicity and the BR-1 mini pig model infected with ME-49 is suitable to monitor experimental toxoplasmosis. PMID:25742268

  11. Extruded upper first molar intrusion: Comparison between unilateral and bilateral miniscrew anchorage.

    PubMed

    Sugii, Mari Miura; Barreto, Bruno de Castro Ferreira; Francisco Vieira-Júnior, Waldemir; Simone, Katia Regina Izola; Bacchi, Ataís; Caldas, Ricardo Armini

    2018-01-01

    The aim of his study was to evaluate the stress on tooth and alveolar bone caused by orthodontic intrusion forces in a supraerupted upper molar, by using a three-dimensional Finite Element Method (FEM). A superior maxillary segment was modeled in the software SolidWorks 2010 (SolidWorks Corporation, Waltham, MA, USA) containing: cortical and cancellous bone, supraerupted first molar, periodontal tissue and orthodontic components. A finite element model has simulated intrusion forces of 4N onto a tooth, directed to different mini-screw locations. Three different intrusion mechanics vectors were simulated: anchoring on a buccal mini-implant; anchoring on a palatal mini-implant and the association of both anchorage systems. All analyses were performed considering the minimum principal stress and total deformation. Qualitative analyses exhibited stress distribution by color maps. Quantitative analysis was performed with a specific software for reading and solving numerical equations (ANSYS Workbench 14, Ansys, Canonsburg, Pennsylvania, USA). Intrusion forces applied from both sides (buccal and palatal) resulted in a more homogeneous stress distribution; no high peak of stress was detected and it has allowed a vertical resultant movement. Buccal or palatal single-sided forces resulted in concentrated stress zones with higher values and tooth tipping to respective force side. Unilateral forces promoted higher stress in root apex and higher dental tipping. The bilateral forces promoted better distribution without evidence of dental tipping. Bilateral intrusion technique suggested lower probability of root apex resorption.

  12. Aerosol lidar observations of atmospheric mixing in Los Angeles: Climatology and implications for greenhouse gas observations

    NASA Astrophysics Data System (ADS)

    Ware, John; Kort, Eric A.; DeCola, Phil; Duren, Riley

    2016-08-01

    Atmospheric observations of greenhouse gases provide essential information on sources and sinks of these key atmospheric constituents. To quantify fluxes from atmospheric observations, representation of transport—especially vertical mixing—is a necessity and often a source of error. We report on remotely sensed profiles of vertical aerosol distribution taken over a 2 year period in Pasadena, California. Using an automated analysis system, we estimate daytime mixing layer depth, achieving high confidence in the afternoon maximum on 51% of days with profiles from a Sigma Space Mini Micropulse LiDAR (MiniMPL) and on 36% of days with a Vaisala CL51 ceilometer. We note that considering ceilometer data on a logarithmic scale, a standard method, introduces, an offset in mixing height retrievals. The mean afternoon maximum mixing height is 770 m Above Ground Level in summer and 670 m in winter, with significant day-to-day variance (within season σ = 220m≈30%). Taking advantage of the MiniMPL's portability, we demonstrate the feasibility of measuring the detailed horizontal structure of the mixing layer by automobile. We compare our observations to planetary boundary layer (PBL) heights from sonde launches, North American regional reanalysis (NARR), and a custom Weather Research and Forecasting (WRF) model developed for greenhouse gas (GHG) monitoring in Los Angeles. NARR and WRF PBL heights at Pasadena are both systematically higher than measured, NARR by 2.5 times; these biases will cause proportional errors in GHG flux estimates using modeled transport. We discuss how sustained lidar observations can be used to reduce flux inversion error by selecting suitable analysis periods, calibrating models, or characterizing bias for correction in post processing.

  13. Aerosol lidar observations of atmospheric mixing in Los Angeles: Climatology and implications for greenhouse gas observations.

    PubMed

    Ware, John; Kort, Eric A; DeCola, Phil; Duren, Riley

    2016-08-27

    Atmospheric observations of greenhouse gases provide essential information on sources and sinks of these key atmospheric constituents. To quantify fluxes from atmospheric observations, representation of transport-especially vertical mixing-is a necessity and often a source of error. We report on remotely sensed profiles of vertical aerosol distribution taken over a 2 year period in Pasadena, California. Using an automated analysis system, we estimate daytime mixing layer depth, achieving high confidence in the afternoon maximum on 51% of days with profiles from a Sigma Space Mini Micropulse LiDAR (MiniMPL) and on 36% of days with a Vaisala CL51 ceilometer. We note that considering ceilometer data on a logarithmic scale, a standard method, introduces, an offset in mixing height retrievals. The mean afternoon maximum mixing height is 770 m Above Ground Level in summer and 670 m in winter, with significant day-to-day variance (within season σ = 220m≈30%). Taking advantage of the MiniMPL's portability, we demonstrate the feasibility of measuring the detailed horizontal structure of the mixing layer by automobile. We compare our observations to planetary boundary layer (PBL) heights from sonde launches, North American regional reanalysis (NARR), and a custom Weather Research and Forecasting (WRF) model developed for greenhouse gas (GHG) monitoring in Los Angeles. NARR and WRF PBL heights at Pasadena are both systematically higher than measured, NARR by 2.5 times; these biases will cause proportional errors in GHG flux estimates using modeled transport. We discuss how sustained lidar observations can be used to reduce flux inversion error by selecting suitable analysis periods, calibrating models, or characterizing bias for correction in post processing.

  14. Intestinal absorption differences of major bioactive compounds of Gegenqinlian Decoction between normal and bacterial diarrheal mini-pigs in vitro and in situ.

    PubMed

    Ling, Xiao; Xiang, Yuqiang; Chen, Feilong; Tang, Qingfa; Zhang, Wei; Tan, Xiaomei

    2018-04-15

    Intestinal condition plays an important role in drug absorption and metabolism, thus the effects of varied gastrointestinal diseases such as infectious diarrhea on the intestinal function are crucial for drug absorption. However, due to the lack of suitable models, the differences of absorption and metabolism of drugs between the diarrheal and normal intestines are rarely reported. Thus, in this study, Escherichia coli diarrhea model was induced in mini-pigs and single-pass intestinal perfusion and intestinal mucosal enzyme metabolism experiments were conducted. A simple and rapid ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to determine the concentrations of 9 major components in Gegen Qinlian decoction (GQD). Samples were pretreated by protein precipitation with methanol and naringin and prednisolone were used as internal standards. The validated method demonstrated adequate sensitivity, selectivity, and process efficiency for the bioanalysis of 9 compounds. Results of intestinal perfusion showed that puerarin, daidzein, daidzin and baicalin and berberine were absorbed faster in diarrheal jejunum than in normal intestines (p < 0.05). However, puerarin, daidzin and liquiritin were metabolized more slowly in diarrheal intestine after incubation compared with the normal group (p < 0.05). The concentrations of daidzein in both perfusion and metabolism and wogonin in metabolism were significantly increased (p < 0.05). In conclusion, absorption and metabolism of GQD were significantly different between the diarrheal and normal intestines, which suggest that bacterial diarrheal mini-pigs model can be used in the intestinal absorption study and is worthy to be applied in the other intestinal absorption study of anti- diarrheal drugs. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Dynamic imaging of cerebral blood flow in rat reperfused mini-stroke model using laser speckle temporal contrast analysis

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Luo, Weihua; Li, Pengcheng; Zeng, Shaoqun; Luo, Qingming

    2007-05-01

    Laser speckle temporal contrast analysis (LSTCA) was used to image the cerebral blood flow (CBF) of ischemic area in reperfused mini-stroke model in rats. Focal cortical ischemia in male Sprague-Dawley rats (n=20) was induced by deliberate ligation of multiple branches of the middle cerebral artery (MCA) together with a nylon ring and the dura. LSTCA was used to monitor the spatio-temporal characteristics of cerebral blood flow dynamics in the rat somatosensory cortex in the ischemic and reperfused stages. The infarction volume was measured by 2, 3, 5- triphenyltetrazolium chloride (TTC) staining 24 hours after reperfusion. The distribution of changes in cerebral blood flow which outlined by the laser speckle imaging represented the relative CBF gradient (21.98+/-1.96%, 67.2+/-1.67 %, 107.24+/-4.71 % of the baseline) from ischemic core, penumbra zone to normal tissue immediately after cortical ischemia, in which a central ischemic core had little or no perfusion surrounded by a penumbral region with reduced perfusion, in addition, we had shown the existence of a surrounding region of hyperemic tissue; Thereafter a postrecanalization hyperperfusion occurred in the same infarct core since 24 hours after reperfusion (242.62+/-18.52% of the baseline). Histology of the ischemic regions at 24 hours after reperfusion revealed small focal infarcts that were typically 3~4 mm in diameter, approximately equal to the nylon ring in size and position and essentially accordant with the spatial distribution of the ischemic cortex with below 30% residual CBF of the pre-ischemic baseline. It was demonstrated that this technique of LSTCA was easy to implement and availably used to image the spatial and temporal evolution of CBF changes with high resolution in rat reperfused mini-stroke model.

  16. Testing charged current quasi-elastic and multinucleon interaction models in the NEUT neutrino interaction generator with published datasets from the MiniBooNE and MINERνA experiments

    NASA Astrophysics Data System (ADS)

    Wilkinson, C.; Terri, R.; Andreopoulos, C.; Bercellie, A.; Bronner, C.; Cartwright, S.; de Perio, P.; Dobson, J.; Duffy, K.; Furmanski, A. P.; Haegel, L.; Hayato, Y.; Kaboth, A.; Mahn, K.; McFarland, K. S.; Nowak, J.; Redij, A.; Rodrigues, P.; Sánchez, F.; Schwehr, J. D.; Sinclair, P.; Sobczyk, J. T.; Stamoulis, P.; Stowell, P.; Tacik, R.; Thompson, L.; Tobayama, S.; Wascko, M. O.; Żmuda, J.

    2016-04-01

    There has been a great deal of theoretical work on sophisticated charged current quasi-elastic (CCQE) neutrino interaction models in recent years, prompted by a number of experimental results that measured unexpectedly large CCQE cross sections on nuclear targets. As the dominant interaction mode at T2K energies, and the signal process in oscillation analyses, it is important for the T2K experiment to include realistic CCQE cross section uncertainties in T2K analyses. To this end, T2K's Neutrino Interaction Working Group has implemented a number of recent models in NEUT, T2K's primary neutrino interaction event generator. In this paper, we give an overview of the models implemented and present fits to published νμ and ν¯ μ CCQE cross section measurements from the MiniBooNE and MINER ν A experiments. The results of the fits are used to select a default cross section model for future T2K analyses and to constrain the cross section uncertainties of the model. We find strong tension between datasets for all models investigated. Among the evaluated models, the combination of a modified relativistic Fermi gas with multinucleon CCQE-like interactions gives the most consistent description of the available data.

  17. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perevalov, Denis

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for v μ → v e neutrino oscillations at Δm 2 ~ 1 eV 2 using an intense neutrino flux with an average energy E v ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 10 21 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral currentmore » π 0, charged current quasi-elastic (CCQE), charged current π +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement of the axial mass, M A, and the Δs parameter from the NCE data.« less

  18. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    NASA Astrophysics Data System (ADS)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement of the axial mass, MA, and the Delta s parameter from the NCE data.

  19. Arabidopsis Chloroplast Mini-Ribonuclease III Participates in rRNA Maturation and Intron Recycling

    PubMed Central

    Hotto, Amber M.; Castandet, Benoît; Gilet, Laetitia; Higdon, Andrea; Condon, Ciarán; Stern, David B.

    2015-01-01

    RNase III proteins recognize double-stranded RNA structures and catalyze endoribonucleolytic cleavages that often regulate gene expression. Here, we characterize the functions of RNC3 and RNC4, two Arabidopsis thaliana chloroplast Mini-RNase III-like enzymes sharing 75% amino acid sequence identity. Whereas rnc3 and rnc4 null mutants have no visible phenotype, rnc3/rnc4 (rnc3/4) double mutants are slightly smaller and chlorotic compared with the wild type. In Bacillus subtilis, the RNase Mini-III is integral to 23S rRNA maturation. In Arabidopsis, we observed imprecise maturation of 23S rRNA in the rnc3/4 double mutant, suggesting that exoribonucleases generated staggered ends in the absence of specific Mini-III-catalyzed cleavages. A similar phenotype was found at the 3′ end of the 16S rRNA, and the primary 4.5S rRNA transcript contained 3′ extensions, suggesting that Mini-III catalyzes several processing events of the polycistronic rRNA precursor. The rnc3/4 mutant showed overaccumulation of a noncoding RNA complementary to the 4.5S-5S rRNA intergenic region, and its presence correlated with that of the extended 4.5S rRNA precursor. Finally, we found rnc3/4-specific intron degradation intermediates that are probable substrates for Mini-III and show that B. subtilis Mini-III is also involved in intron regulation. Overall, this study extends our knowledge of the key role of Mini-III in intron and noncoding RNA regulation and provides important insight into plastid rRNA maturation. PMID:25724636

  20. Peak insertion torque values of five mini-implant systems under different insertion loads.

    PubMed

    Quraishi, Erma; Sherriff, Martyn; Bister, Dirk

    2014-06-01

    To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.

  1. Development of a new mini-invasive tumour hyperthermia probe using high-temperature water vapour.

    PubMed

    Yu, Tian-Hua; Zhou, Yi-Xin; Liu, Jing

    2004-01-01

    A new mini-invasive hyperthermia probe using high-temperature water vapour for deep regional tumour treatment was developed in this paper. The vacuum insulation mechanism was incorporated into the probe to avoid heating damage to the normal tissues around the edge of the insertion path. To better understand the heat transfer behaviour in living tissues due to operation of the probe, theoretical models based on the Pennes' equation were established and two closed form analytical solutions under constant flux or temperature heating at the tip of probe were obtained. Parametric studies were performed to investigate the influence of various parameters on the temperature response of tissues heated by the probe. Further, several simulating experiments on the actual heating performance of the probe fabricated in this paper were conducted on the in vitro biological materials (fresh pork) and phantom gel. It was demonstrated that the probe can cause a high enough temperature over the treatment area to thermally destroy the tumour tissue in due time, while the temperature over the surrounding healthy tissues can be kept below a safe threshold value. This mini-invasive heating probe may have significant applications in future clinical tumour hyperthermia.

  2. Suicidality, self-stigma, social anxiety and personality traits in stabilized schizophrenia patients - a cross-sectional study.

    PubMed

    Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Holubova, Michaela; Kantor, Krystof; Kolek, Antonin; Grambal, Aleš; Slepecky, Milos

    2018-01-01

    Patients who have schizophrenia are more prone to suicidal behavior than the general population. This study aimed to find connections between suicidality and self-stigma, hope, and personality traits in patients with schizophrenia. Forty-eight stabilized outpatients with schizophrenia attended this cross-sectional study. Patients were diagnosed by the Mini International Neuropsychiatric Interview (MINI) using the ICD-10 research diagnostic criteria. The assessments included Positive and Negative Syndrome Scale, objective and subjective Clinical Global Impression, Liebowitz Social Anxiety Scale, Beck Depression Inventory-second edition, Internalized Stigma of Mental Illness, the Temperament and Character Inventory, and Adult Dispositional Hope Scale. The individual rate of suicidality (suicidal index from MINI) strongly positively correlated with self-stigma, level of depression, social anxiety, and harm-avoidance, and negatively correlated with hope, self-directedness, and stigma resistance. Individuals with additional symptoms of depression, social anxiety, trait-like anxiety, and self-stigma should be carefully monitored for suicidal ideation. On the opposite side, patients with sufficient hope, self-esteem, and goal-directed attitudes are less likely to have suicidal thoughts and may potentially be role models in group rehabilitation programs, motivating more distressed colleagues and showing them ways to cope.

  3. New Directions for Preventing Dating Violence in Adolescence: The Study of Gender Models

    PubMed Central

    Santoro, Chiara; Martínez-Ferrer, Belén; Monreal Gimeno, Carmen; Musitu, Gonzalo

    2018-01-01

    Dating violence is a huge transcultural and alarming phenomenon, directly linked with endless discrimination against women. The latest research on dating violence in adolescence shows how dating violence is persistent and common in the adolescent period as well and pinpoints the origin of gender violence from first adolescent relationships. This element takes us to considerate how recent gender violence studies and policies, increased also thanks to international efforts on this issue, are not bringing expected results, especially among young people. This mini-review aims to analyze the main characteristics of current gender studies and policies on dating violence, focusing on percentages with a woman-centered approach, which stresses the consequences of gender violence. Other gender studies, that consider gender as a relational product, stress the importance of integrating the analysis of gender models as a key instrument to understand the main causes of dating violence, providing new elements to develop effective policies against dating violence. Indeed, gender models of femininity and masculinity are based on a binary system, which is also a reciprocal recognition and identity system: gender models define female and male characteristics, roles, stereotypes, and expectation, being complementary and foreclosing at the same time. Recent studies on gender relationships, especially among the youth, allows us to propose a new dialog between dating violence studies and gender model studies, underling the need of a complete and complex understanding of gender structure, and of its tensions and contradictions, to put an end to gender and dating violence, through effective programs. PMID:29946282

  4. 78 FR 17738 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-22

    ... customer bases of potential product users have indicated a preference that premium pricing for Mini Options... market participants clarity as to the minimum pricing increments for Mini Options, the filing would harmonize penny pricing between Mini Options and standard options on the same security. \\4\\ See Securities...

  5. 78 FR 17970 - Self-Regulatory Organizations; Miami International Securities Exchange LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-25

    ... product users and they have indicated a preference that premium pricing for mini-options match what is... market participants clarity as to the minimum pricing increments for mini-options, the filing would harmonize penny pricing between mini-options and standard options on the same security. \\3\\ See Securities...

  6. Bridging the Gap in Volleyball. From Basic Instruction to Game Play.

    ERIC Educational Resources Information Center

    Dawson, Linda; Polvino, Geri

    1982-01-01

    Using volleyball "mini games," which emphasize, one at a time, skills needed to play volleyball, helps students to develop skills needed to play. Mini games described are: (1) forearm pass; (2) overhand pass; (3) overhand pass; (4) overhand serve; (5) mini volleyball; and (6) alternate court set-up. (CJ)

  7. Mini-rack testbed evaluation

    NASA Technical Reports Server (NTRS)

    Gosbee, John; Stegmann, Barbara; Guess, Terrell M.

    1991-01-01

    The goal was to characterize the Health Maintenance Facility (HMF)-like mini-racks and drawers onboard the KC-135 as a test bed for the Space Station Freedom HMF racks. An additional goal was to evaluate the attachments, mounting points, and inner drawer assemblies of the mini-racks for various medical equipment and supplies. Results and recommendations are given.

  8. Shortcuts for Pilot Testing Instructional Materials.

    ERIC Educational Resources Information Center

    Howe, R. John; Pearlstein, Gloria

    1995-01-01

    A mini-pilot test was conducted by the Department of Labor's Employment Standards Administration to develop training on enforcing the Federal Family and Medical Leave Act. The situation that necessitated the test is presented; mini-pilot test examples are explained; and pros and cons of the mini-pilots are examined. A sidebar contains suggestions…

  9. Protective Factor Screening for Prevention Practice: Sensitivity and Specificity of the Dessa-Mini

    ERIC Educational Resources Information Center

    Shapiro, Valerie B.; Kim, B. K. Elizabeth; Robitaille, Jennifer L.; LeBuffe, Paul A.

    2017-01-01

    The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a…

  10. Mini-Concerts: Creating Space for Student-Initiated Performance

    ERIC Educational Resources Information Center

    Gifford, Cody; Johnson, Erik

    2015-01-01

    Mini-concerts are regularly occurring, low-stakes curricular events in the classroom where students perform music of their choice for their peers. An idea generated by music educators in domestic and international K-12 schools who strive to meet the needs of diverse student populations, mini-concerts have helped generate student excitement and…

  11. Gender and Self-Employment: The Role of Mini-Companies

    ERIC Educational Resources Information Center

    Johansen, Vegard

    2016-01-01

    Purpose: The purpose of this paper is to evaluate to what degree participation in mini-companies impact young women and men with regard to the perceived desirability and perceived feasibility of self-employment. The Company Programme (CP) is the largest mini-company scheme in European secondary school. Design/methodology/approach: The data derived…

  12. The Genesis of Creative Greatness: Mini-C and the Expert Performance Approach

    ERIC Educational Resources Information Center

    Beghetto, Ronald A.; Kaufman, James C.

    2007-01-01

    The authors' recent theoretical work has focused on developing the construct of mini-c creativity and illustrating how all levels of creative performance follow a trajectory that starts with novel and personally meaningful interpretations (mini-c), which can then progress to intrapersonally judged novel and meaningful contributions (little-c) and…

  13. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF TECHNOLOGIES FOR MEASURING TRACE ELEMENTS IN SOIL AND SEDIMENT RIGAKU ZSX MINI 11 XRF ANALYZER

    EPA Science Inventory

    The Rigaku ZSX Mini II (ZSX Mini II) XRF Services x-ray fluorescence (XRF) analyzer was demon-strated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2...

  14. Mini-Digest of Education Statistics, 2008. NCES 2009-021

    ERIC Educational Resources Information Center

    Snyder, Thomas D.

    2009-01-01

    This publication is the 14th edition of the "Mini-Digest of Education Statistics," a pocket-sized compilation of statistical information covering the broad field of American education from kindergarten through graduate school. The "Mini-Digest" is designed as an easy reference for materials found in much greater detail in the…

  15. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents

    PubMed Central

    Garcia-Lopez, LuisJoaquín; Moore, Harry T. A.

    2015-01-01

    Objectives Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. Methods The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Results Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Conclusions Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided. PMID:26317695

  16. A regulatory toolbox of MiniPromoters to drive selective expression in the brain

    PubMed Central

    Portales-Casamar, Elodie; Swanson, Douglas J.; Liu, Li; de Leeuw, Charles N.; Banks, Kathleen G.; Ho Sui, Shannan J.; Fulton, Debra L.; Ali, Johar; Amirabbasi, Mahsa; Arenillas, David J.; Babyak, Nazar; Black, Sonia F.; Bonaguro, Russell J.; Brauer, Erich; Candido, Tara R.; Castellarin, Mauro; Chen, Jing; Chen, Ying; Cheng, Jason C. Y.; Chopra, Vik; Docking, T. Roderick; Dreolini, Lisa; D'Souza, Cletus A.; Flynn, Erin K.; Glenn, Randy; Hatakka, Kristi; Hearty, Taryn G.; Imanian, Behzad; Jiang, Steven; Khorasan-zadeh, Shadi; Komljenovic, Ivana; Laprise, Stéphanie; Liao, Nancy Y.; Lim, Jonathan S.; Lithwick, Stuart; Liu, Flora; Liu, Jun; Lu, Meifen; McConechy, Melissa; McLeod, Andrea J.; Milisavljevic, Marko; Mis, Jacek; O'Connor, Katie; Palma, Betty; Palmquist, Diana L.; Schmouth, Jean-François; Swanson, Magdalena I.; Tam, Bonny; Ticoll, Amy; Turner, Jenna L.; Varhol, Richard; Vermeulen, Jenny; Watkins, Russell F.; Wilson, Gary; Wong, Bibiana K. Y.; Wong, Siaw H.; Wong, Tony Y. T.; Yang, George S.; Ypsilanti, Athena R.; Jones, Steven J. M.; Holt, Robert A.; Goldowitz, Daniel; Wasserman, Wyeth W.; Simpson, Elizabeth M.

    2010-01-01

    The Pleiades Promoter Project integrates genomewide bioinformatics with large-scale knockin mouse production and histological examination of expression patterns to develop MiniPromoters and related tools designed to study and treat the brain by directed gene expression. Genes with brain expression patterns of interest are subjected to bioinformatic analysis to delineate candidate regulatory regions, which are then incorporated into a panel of compact human MiniPromoters to drive expression to brain regions and cell types of interest. Using single-copy, homologous-recombination “knockins” in embryonic stem cells, each MiniPromoter reporter is integrated immediately 5′ of the Hprt locus in the mouse genome. MiniPromoter expression profiles are characterized in differentiation assays of the transgenic cells or in mouse brains following transgenic mouse production. Histological examination of adult brains, eyes, and spinal cords for reporter gene activity is coupled to costaining with cell-type–specific markers to define expression. The publicly available Pleiades MiniPromoter Project is a key resource to facilitate research on brain development and therapies. PMID:20807748

  17. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    PubMed

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  18. The Formation of Mini-Neptunes

    NASA Astrophysics Data System (ADS)

    Venturini, Julia; Helled, Ravit

    2017-10-01

    Mini-Neptunes seem to be common planets. In this work we investigate the possible formation histories and predicted occurrence rates of mini-Neptunes, assuming that the planets form beyond the iceline. We consider pebble and planetesimal accretion accounting for envelope enrichment and two different opacity conditions. We find that the formation of mini-Neptunes is a relatively frequent output when envelope enrichment by volatiles is included, and that there is a “sweet spot” for mini-Neptune formation with a relatively low solid accretion rate of ˜10-6 M ⊕ yr-1. This rate is typical for low/intermediate-mass protoplanetary disks and/or disks with low metallicities. With pebble accretion, envelope enrichment and high opacity favor the formation of mini-Neptunes, with more efficient formation at large semimajor axes (˜30 au) and low disk viscosities. For planetesimal accretion, such planets can also form without enrichment, with the opacity being a key aspect in the growth history and favorable formation location. Finally, we show that the formation of Neptune-like planets remains a challenge for planet formation theories.

  19. Effect of pre-drilling on intraosseous temperature during self-drilling mini-implant placement in a porcine mandible model.

    PubMed

    Gurdán, Zsuzsanna; Vajta, László; Tóth, Ákos; Lempel, Edina; Joób-Fancsaly, Árpád; Szalma, József

    2017-03-31

    This in vitro study investigated intraos seous heat production during insertion, with and without pre-drilling, of a self-drilling orthodontic mini-implant. To measure temperature changes and drilling times in pig ribs, a special testing apparatus was used to examine new and worn pre-drills at different speeds. Temperatures were measured during mini-implant placement with and without pre-drilling. The average intraosseous temperature increase during manual mini-implant insertion was similar with and without pre-drilling (11.8 ± 2.1°C vs. 11.3 ± 2.4°C, respectively; P = 0.707). During pre-drilling the mean temperature increase for new drills was 2.1°C at 100 rpm, 2.3°C at 200 rpm, and 7.6°C at 1,200 rpm. Temperature increases were significantly higher for worn drills at the same speeds (2.98°C, 3.0°C, and 12.3°C, respectively), while bone temperatures at 100 and 200 rpm were similar for new and worn drills (P = 0.345 and 0.736, respectively). Baseline bone temperature was approximated within 30 s after drilling in most specimens. Drilling time at 100 rpm was 2.1 ± 0.9 s, but was significantly shorter at 200 rpm (1.1 ± 0.2 s) and 1,200 rpm (0.1 ± 0.03 s). Pre-drilling did not decrease intraosseous temperatures. In patients for whom pre-drilling is indicated, speeds of 100 or 200 rpm are recommended, at least 30 s after pilot drilling.

  20. Metabolic adaptations to HFHS overfeeding: how whole body and tissues postprandial metabolic flexibility adapt in Yucatan mini-pigs.

    PubMed

    Polakof, Sergio; Rémond, Didier; Bernalier-Donadille, Annick; Rambeau, Mathieu; Pujos-Guillot, Estelle; Comte, Blandine; Dardevet, Dominique; Savary-Auzeloux, Isabelle

    2018-02-01

    In the present study, we aimed to metabolically characterize the postprandial adaptations of the major tissues involved in energy, lipids and amino acids metabolisms in mini-pigs. Mini-pigs were fed on high-fat-high-sucrose (HFHS) diet for 2 months and several tissues explored for metabolic analyses. Further, the urine metabolome was followed over the time to picture the metabolic adaptations occurring at the whole body level following overfeeding. After 2 months of HFHS consumption, mini-pigs displayed an obese phenotype characterized by high circulating insulin, triglycerides and cholesterol levels. At the tissue level, a general (muscle, adipose tissue, intestine) reduction in the capacity to phosphorylate glucose was observed. This was also supported by the enhanced hepatic gluconeogenesis potential, despite the concomitant normoglycaemia, suggesting that the high circulating insulin levels would be enough to maintain glucose homoeostasis. The HFHS feeding also resulted in a reduced capacity of two other pathways: the de novo lipogenesis, and the branched-chain amino acids transamination. Finally, the follow-up of the urine metabolome over the time allowed determining breaking points in the metabolic trajectory of the animals. Several features confirmed the pertinence of the animal model, including increased body weight, adiposity and porcine obesity index. At the metabolic level, we observed a perturbed glucose and amino acid metabolism, known to be related to the onset of the obesity. The urine metabolome analyses revealed several metabolic pathways potentially involved in the obesity onset, including TCA (citrate, pantothenic acid), amino acids catabolism (cysteine, threonine, leucine).

  1. Investigation of a robust tendon-sheath mechanism for flexible membrane wing application in mini-UAV

    NASA Astrophysics Data System (ADS)

    Lee, Shian; Tjahjowidodo, Tegoeh; Lee, Hsuchew; Lai, Benedict

    2017-02-01

    Two inherent issues manifest themselves in flying mini-unmanned aerial vehicles (mini-UAV) in the dense area at tropical climate regions, namely disturbances from gusty winds and limited space for deployment tasks. Flexible membrane wing (FMW) UAVs are seen to be potentials to mitigate these problems. FMWs are adaptable to gusty airflow as the wings are able to flex according to the gust load to reduce the effective angle-of-attack, thus, reducing the aerodynamic loads on the wing. On the other hand, the flexible structure is allowing the UAV to fold in a compact package, and later on, the mini-UAV can be deployed instantly from the storage tube, e.g. through a catapult mechanism. This paper discusses the development of an FMW UAV actuated by a tendon-sheath mechanism (TSM). This approach allows the wing to morph to generate a rolling moment, while still allowing the wing to fold. Dynamic characteristics of the mechanism that exhibits the strong nonlinear phenomenon of friction on TSM are modeled and compensated for. A feed-forward controller was implemented based on the identified nonlinear behavior to control the warping position of the wing. The proposed strategy is validated experimentally in a wind tunnel facility by creating a gusty environment that is imitating a realistic gusty condition based upon the results of computational fluid dynamics (CFD) simulation. The results demonstrate a stable and robust wing-warping actuation, even in gusty conditions. Accurate wing-warping can be achieved via the TSM, while also allowing the wings to fold.

  2. Dietary protein intake affects expression of genes for lipid metabolism in porcine skeletal muscle in a genotype-dependent manner.

    PubMed

    Liu, Yingying; Li, Fengna; He, Lingyun; Tan, Bie; Deng, Jinping; Kong, Xiangfeng; Li, Yinghui; Geng, Meimei; Yin, Yulong; Wu, Guoyao

    2015-04-14

    Skeletal muscle is a major site for the oxidation of fatty acids (FA) in mammals, including humans. Using a swine model, we tested the hypothesis that dietary protein intake regulates the expression of key genes for lipid metabolism in skeletal muscle. A total of ninety-six barrows (forty-eight pure-bred Bama mini-pigs (fatty genotype) and forty-eight Landrace pigs (lean genotype)) were fed from 5 weeks of age to market weight. Pigs of fatty or lean genotype were randomly assigned to one of two dietary treatments (low- or adequate-protein diet), with twenty-four individually fed pigs per treatment. Our data showed that dietary protein levels affected the expression of genes involved in the anabolism and catabolism of lipids in the longissimus dorsi and biceps femoris muscles in a genotype-dependent manner. Specifically, Bama mini-pigs had more intramuscular fat, SFA and MUFA, as well as elevated mRNA expression levels of lipogenic genes, compared with Landrace pigs. In contrast, Bama mini-pigs had lower mRNA expression levels of lipolytic genes than Landrace pigs fed an adequate-protein diet in the growing phase. These data are consistent with higher white-fat deposition in Bama mini-pigs than in Landrace pigs. In conclusion, adequate provision of dietary protein (amino acids) plays an important role in regulating the expression of key lipogenic genes, and the growth of white adipose tissue, in a genotype- and tissue-specific manner. These findings have important implications for developing novel dietary strategies in pig production.

  3. How to Analyze Verbal and Nonverbal Classroom Communication.

    ERIC Educational Resources Information Center

    Heger, Herbert K.

    Based upon the communications process model of teaching and learning, the Miniaturized Total Interaction Analysis System (Mini-TIA) establishes a conceptual framework for observing symptomatic classroom behaviors. It provides a means for the evaluation of classroom communication. Interpersonal communication is defined as either verbal (using…

  4. New light Higgs boson and short-baseline neutrino anomalies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asaadi, J.; Church, E.; Guenette, R.

    The low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for non-zero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward-scattering off of a locally over-dense relic neutrino background give rise to a novel matter-effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino- and antineutrino-mode data sets. The model provides substantially improvedmore » $$\\chi^2$$ values beyond either the no-oscillation hypothesis or the more commonly explored 3+1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming SBN program at Fermilab, presenting opportunities for further exploration.« less

  5. New light Higgs boson and short-baseline neutrino anomalies

    DOE PAGES

    Asaadi, J.; Church, E.; Guenette, R.; ...

    2018-04-16

    Here, the low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for nonzero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward scattering off of a locally overdense relic neutrino background give rise to a novel matter effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino-more » and antineutrino-mode data sets. The model provides substantially improved χ2 values beyond either the no-oscillation hypothesis or the more commonly explored 3+1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming short-baseline neutrino program at Fermilab, presenting opportunities for further exploration.« less

  6. New light Higgs boson and short-baseline neutrino anomalies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asaadi, J.; Church, E.; Guenette, R.

    Here, the low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for nonzero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward scattering off of a locally overdense relic neutrino background give rise to a novel matter effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino-more » and antineutrino-mode data sets. The model provides substantially improved χ2 values beyond either the no-oscillation hypothesis or the more commonly explored 3+1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming short-baseline neutrino program at Fermilab, presenting opportunities for further exploration.« less

  7. Therapeutic effect of topical application of curcumin during treatment of radiation burns in a mini-pig model

    PubMed Central

    Park, Sunhoo; Jeon, Byung-Suk; Jang, Won-Seok; Lee, Sun-Joo; Son, Yeonghoon; Rhim, Kyung-Jin; Lee, Soong In

    2016-01-01

    Curcumin protects the skin against radiation-induced epidermal damage and prevents morphological changes induced by irradiation skin, thereby maintaining the epidermal thickness and cell density of basal layers. In this study, the effects of topical curcumin treatment on radiation burns were evaluated in a mini-pig model. Histological and clinical changes were observed five weeks after radiation exposure to the back (60Co gamma-radiation, 50 Gy). Curcumin was applied topically to irradiated skin (200 mg/cm2) twice a day for 35 days. Curcumin application decreased the epithelial desquamation after irradiation. Additionally, when compared to the vehicle-treated group, the curcumin-treated group showed reduced expression of cyclooxygenase-2 and nuclear factor-kappaB. Furthermore, irradiation prolonged healing of biopsy wounds in the exposed area, whereas curcumin treatment stimulated wound healing. These results suggest that curcumin can improve epithelial cell survival and recovery in the skin and therefore be used to treat radiation burns. PMID:27030193

  8. A WRKY transcription factor recruits the SYG1-like protein SHB1 to activate gene expression and seed cavity enlargement.

    PubMed

    Kang, Xiaojun; Li, Wei; Zhou, Yun; Ni, Min

    2013-01-01

    Seed development in Arabidopsis and in many dicots involves an early proliferation of the endosperm to form a large embryo sac or seed cavity close to the size of the mature seed, followed by a second phase during which the embryo grows and replaces the endosperm. Short hypocotyl under BLUE1 (SHB1) is a member of the SYG1 protein family in fungi, Caenorhabditis elegans, flies, and mammals. SHB1 gain-of-function enhances endosperm proliferation, increases seed size, and up-regulates the expression of the WRKY transcription factor gene MINISEED3 (MINI3) and the LRR receptor kinase gene HAIKU2 (IKU2). Mutations in either IKU2 or MINI3 retard endosperm proliferation and reduce seed size. However, the molecular mechanisms underlying the establishment of the seed cavity and hence the seed size remain largely unknown. Here, we show that the expression of MINI3 and IKU2 is repressed before fertilization and after 4 days after pollination (DAP), but is activated by SHB1 from 2 to 4 DAP prior to the formation of the seed cavity. SHB1 associates with their promoters but without a recognizable DNA binding motif, and this association is abolished in mini3 mutant. MINI3 binds to W-boxes in, and recruits SHB1 to, its own and IKU2 promoters. Interestingly, SHB1, but not MINI3, activates transcription of pMINI3::GUS or pIKU2::GUS. We reveal a critical developmental switch through the activation of MINI3 expression by SHB1. The recruitment of SHB1 by MINI3 to its own and IKU2 promoters represents a novel two-step amplification to counter the low expression level of IKU2, which is a trigger for endosperm proliferation and seed cavity enlargement.

  9. Temporary anchorage devices (TADs) in orthodontics: review of the factors that influence the clinical success rate of the mini-implants.

    PubMed

    Leo, M; Cerroni, L; Pasquantonio, G; Condò, S G; Condò, R

    2016-01-01

    The mini-implant, temporary anchorage devices (TADS), are now a common method of treatment in Orthodontics with versatility, minimal invasiveness and the relationship between costs and benefits that they offer even today. Skeletal anchorage has, to a large degree, replaced conventional anchorage in situations where anchorage is considered either critical, insufficient, or likely to result in undesirable side effects such as vertical displacements generated by inter-maxillary force systems. The objective of this study is to carry out a review about the factors that seem affect the success or failure rate of orthodontic mini-implants. A computerized literature review was performed by searching the MEDLINE database (Entrez PubMed, www.ncbi.nlm.nih.gov), Google Scholar, Scopus, Cochrane Central Register of Controlled Trials, Isi Web of Knowledge until March 2016 . The main subject heading "orthodontics" was combined with these keywords mini-implant, mini-screw, micro-implants, mini-implant success rate, mini-implant failure rate, skeletal anchorage, temporary anchorage device (TADS). In the selection process, abstracts were initially read independently by two researchers to identify potentially eligible full text papers which were then retrieved and assessed in order to decide on the final inclusion. The clinical success of orthodontic anchorage by mini-implants depends on the stability of the miniscrews used for fixation. For good stability, the application site must provide bone of good quantity and quality. We can reasonably assume that the stability of the anchorage of the mini-implants could be optimized by selecting a position with particular characteristics of quality and quantity of bone, in relation to cortical and total mandibular and jaw bone thickness. These expected informations are important because they indicates that the bone quality and quantity are significant when considering an implant placement site, but also that there are other confounding factors influencing the success rate.

  10. The use of mini-samples in palaeomagnetism

    NASA Astrophysics Data System (ADS)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of particular advantage when carrying out palaeointensity experiments.

  11. Giant mini-clusters as possible origin of halo phenomena observed in super-families

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Among 91 mini-clusters from 30 high energy Chiron-type families in Chacaltaya emulsion chambers, there were observed several extremely large multiplicity clusters in the highest energy range, far beyond the average of ordinary type clusters. Some details of microscopic observation of those giant mini-clusters in nuclear emulsion plates and some phenomenological regularity found in common among them are described. Such giant mini-clusters are possible candidates for the origin of narrow symmetric single halo phenomena in X-ray films which are frequently observed in super-families of visible energy greater than 1,000 TeV.

  12. Rare complication of needleless mini-sling procedure: Case report.

    PubMed

    Karalar, Mustafa; Keles, Ibrahim; Unlu, Serdar; Sarici, Hasmet; Kose, Mesut; Ay, Cemil

    2017-01-01

    The mini-sling procedure is a widely used, minimally invasive treatment for stress urinary incontinence. While bladder perforation and stone formation over the mesh is not an expected complication of the mini-sling procedure, in this case, we report on the management of bladder calculi formed over the mesh, which was passed through the bladder while applying the mini-sling procedure, and was eventually removed using holmium laser. Performing cystoscopy in patients with irritative and obstructive symptoms after the sling procedure will help confirm bladder perforation, and an endoscopic approach using holmium laser is an effective treatment.

  13. Mu-driven transposition of recombinant mini-Mu unit DNA in the Corynebacterium glutamicum chromosome.

    PubMed

    Gorshkova, Natalya V; Lobanova, Juliya S; Tokmakova, Irina L; Smirnov, Sergey V; Akhverdyan, Valerii Z; Krylov, Alexander A; Mashko, Sergey V

    2018-03-01

    A dual-component Mu-transposition system was modified for the integration/amplification of genes in Corynebacterium. The system consists of two types of plasmids: (i) a non-replicative integrative plasmid that contains the transposing mini-Mu(LR) unit bracketed by the L/R Mu ends or the mini-Mu(LER) unit, which additionally contains the enhancer element, E, and (ii) an integration helper plasmid that expresses the transposition factor genes for MuA and MuB. Efficient transposition in the C. glutamicum chromosome (≈ 2 × 10 -4 per cell) occurred mainly through the replicative pathway via cointegrate formation followed by possible resolution. Optimizing the E location in the mini-Mu unit significantly increased the efficiency of Mu-driven intramolecular transposition-amplification in C. glutamicum as well as in gram-negative bacteria. The new C. glutamicum genome modification strategy that was developed allows the consequent independent integration/amplification/fixation of target genes at high copy numbers. After integration/amplification of the first mini-Mu(LER) unit in the C. glutamicum chromosome, the E-element, which is bracketed by lox-like sites, is excised by Cre-mediated fashion, thereby fixing the truncated mini-Mu(LR) unit in its position for the subsequent integration/amplification of new mini-Mu(LER) units. This strategy was demonstrated using the genes for the citrine and green fluorescent proteins, yECitrine and yEGFP, respectively.

  14. Mini-implants for Orthodontic Anchorage: Surface Analysis after Redrilling and Sterilization - An in vitro Study.

    PubMed

    Gross, J M; Nascimento, G G; Araújo, V C; Bönecker, Mjs; Furuse, C

    2016-04-01

    This study aimed to investigate, in vitro, possible alterations on mini-implants surface after retrieval and if the cleaning process and sterilization can predispose damages. Two commercial mini-implants were tested for deformations after drilling and removing in artificial bone four times. Samples were analyzed by scanning electron microscopy, and surface alterations verified through thread and pitches deformation. To alterations caused by insertion/removal and the cleaning process and sterilization were verified in different procedures: Insertions and sterilization, only insertions, and only sterilization. Photomicrographs were analyzed in order to compare the surface characteristics. Head deformation was verified qualitatively. For a quantitative analysis, distances between threads were measured across the active part of the mini-implants. No deformation was observed in both groups. The cleaning and sterilization processes did not provoke alteration in both groups. Nevertheless, the presence of synthetic bone was noted in some samples. The mean distances between implant threads were similar after all steps in all regions in both groups. The results suggest that the tested mini-implants can be retrieved without damage of its surface after four cycles of insertion, removal, and sterilization. Orthodontic mini-implant, Redrilling, Sterilization. Mini-implants can be retrieved without damage to its surface after four cycles of insertion, removal, and sterilization in the same patient without representing a biological concern.

  15. Congenital hypogonadotropic hypogonadism: implications of absent mini-puberty.

    PubMed

    Dwyer, Andrew A; Jayasena, Channa N; Quinton, Richard

    2016-06-01

    The phenomenon known as "mini-puberty" refers to activation of the neonatal hypothalamo-pituitary axis causing serum concentrations of gonadotrophins and testosterone (T) to approach adult male levels. This early neonatal period is a key proliferative window for testicular germ cells and immature Sertoli cells. Although failure to spontaneously initiate (adolescent) puberty is the most evident consequence of a defective gonadotropin-releasing hormone (GnRH) neurosecretory network, absent mini-puberty is also likely to have a major impact on the reproductive phenotype of men with congenital hypogonadotrophic hypogonadism (CHH). Furthermore, the phase of male mini-puberty represents a key window-of-opportunity to identify congenital GnRH deficiency (either isolated CHH, or as part of combined pituitary hormone deficiency) in childhood. Among male neonates exhibiting "red flag" indicators for CHH (i.e. maldescended testes with or without cryptorchidism) a single serum sample (between 4-8 weeks of life) can pinpoint congenital GnRH deficiency far more rapidly and with much greater accuracy than dynamic tests performed in later childhood or adolescence. Potential consequences for missing absent mini-puberty in a male neonate include the lack of monitoring of pubertal progression/lack of progression, and the missed opportunity for early therapeutic intervention. This article will review our current understanding of the mechanisms and clinical consequences of mini-puberty. Furthermore, evidence for the optimal clinical management of patients with absent mini-puberty will be discussed.

  16. Research for the Classroom: Mini Vocabulary Lessons for Maximum Recall

    ERIC Educational Resources Information Center

    Sovereen, Deanne

    2013-01-01

    "Research for the Classroom" publishes mini-studies of ELA classroom practices and suggests ways in which high school and middle school English teachers may study the effectiveness of their pedagogy. The author of this mini-study notes that it takes around six minutes per day of instructional time for students to remember most of the…

  17. Mini-Versus Traditional: An Experimental Study of High School Social Studies Curricula.

    ERIC Educational Resources Information Center

    Roberts, Arthur D.; Gable, Robert K.

    This study assessed some of the cognitive and affective elements for both the traditional and mini curricula. The hypothesis, stated in the null form, was there will be no difference between students in the mini-course curriculum and the traditional curriculum on a number of stated cognitive variables (focusing on critical thinking and reading…

  18. Establishment and characterization of an open mini-thoracotomy surgical approach to an ovine thoracic spine fusion model.

    PubMed

    Yong, Mostyn R N O; Saifzadeh, Siamak; Askin, Geoffrey N; Labrom, Robert D; Hutmacher, Dietmar W; Adam, Clayton J

    2014-01-01

    A large animal model is required for the assessment of minimally invasive, tissue-engineering-based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here, we develop a novel open mini-thoracotomy approach in an ovine model of thoracic interbody fusion that allows the assessment of various fusion constructs, with a focus on novel, tissue-engineering-based interventions. The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances that were required of the study. Six male Merino sheep aged 4-6 years and weighing 35-45 kg underwent the procedure mentioned earlier and were alloted a survival timeline of 6 months. Each sheep underwent a three-level discectomy (T6/7, T8/9, and T10/11) with a randomly allocated implantation of a different graft substitute at each of the following three levels: (1) polycaprolactone (PCL)-based scaffold plus 0.54 μg recombinant human bone morphogenetic protein-2 (rhBMP-2); (2) PCL-based scaffold alone; or (3) autograft. The sheep were closely monitored postoperatively for signs of pain (i.e., gait abnormalities/teeth gnawing/social isolation). Fusion assessments were conducted postsacrifice using computed tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol that was approved by the Institute's committee on animal research. All six sheep were successfully operated on and reached the allotted survival timeline, thereby demonstrating the feasibility of the surgical procedure and postoperative care. There were no significant complications and during the postoperative period, the animals did not exhibit marked signs of distress according to the previously described assessment criteria. Computed tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by a histological evaluation of the respective groups. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method that can reproducibly form the platform for research into various spine-tissue-engineered constructs and their fusion-promoting properties.

  19. Eutrophic overgrowth in the self-organization of tropical wetlands illustrated with a study of swine wastes in rainforest plots

    Treesearch

    Roberta Kent; H.T. Odum; F.N. Scatena

    2000-01-01

    The relationship of plant species diversity to cultural eutrophy in tropical wetlands was studied in Puerto Rico with experimental plots, a survey of 25 eutrophic sites developing from the wastes of society, and a simulation mini-model. The model is a quantitative hypothesis which contains the mechanisms to maximize empower (gross production) by reinforcing low...

  20. The Mini-Course as a Model for the Continuing Education of Teachers. C.A.T. Education Monograph No. 13.

    ERIC Educational Resources Information Center

    Meyer, Rex

    The purpose of this monograph is to discuss the minicourse as a model for the continuing education of teachers. The first section defines the minicourse and describes its evolution. The second section discusses the characteristics of the minicourses at the Centre for Advancement of Teaching (CAT) at Macquarie University, New South Wales,…

  1. Application of partial differential equation modeling of the control/structural dynamics of flexible spacecraft

    NASA Technical Reports Server (NTRS)

    Taylor, Lawrence W., Jr.; Rajiyah, H.

    1991-01-01

    Partial differential equations for modeling the structural dynamics and control systems of flexible spacecraft are applied here in order to facilitate systems analysis and optimization of these spacecraft. Example applications are given, including the structural dynamics of SCOLE, the Solar Array Flight Experiment, the Mini-MAST truss, and the LACE satellite. The development of related software is briefly addressed.

  2. The clinical and radiological results of arthroscopic versus arthroscopy assisted mini-open repair of rotator cuff tears

    PubMed Central

    Özcan, Muhammed Sefa; Sezer, Hasan Basri; Eren, Osman Tuğrul; Armağan, Raffi; Kanar, Muharrem

    2017-01-01

    In this study we reported retrospectively the comperative clinical and radiological results of the two most common surgical procedures in rotator cuff tear repair of shoulder, the golden standart arthroscopic and alternative arthroscopically assisted mini-open surgery. We included 58 patients who admitted to our clinic for rotator cuff tear and treated surgically between january 2013 and august 2015. The two groups were composed of arthroscopically treated 29 patients and 29 patients who were treated with arthroscopically assisted mini open surgery. The arthroscopy group included 18 females and 11 males, the mini-open group included 10 females and 19 males. The mean age was 56,0 (39,0-73,0) years, in arthroscopic and 55,0 (40,0-70,0) years in mini-open surgery group. 6 patients in the arthroscopy group(20,7%) and 10 patients in the mini-open group(34,5%) were defining trauma before the beginning of their complaints. The postoperative follow up was 28,9 months in arthroscopy group and 22,6 months in the mini-open surgery group. Preoperative physical or medical treatments were documented. Any additional surgical procedures like biceps long head tenotomy, subacromial decompression and bursectomy were also noted. Patients were evaluated with ASES and Constant shoulder scales before and after the surgery. Patients were evaluated radiologically with MRI at the last follow up for healing and tendon quality. The type 2 acromion was the dominant in both groups constituting the 44,8% of the total number of patients. 24 (82,8%)patients in the arthroscopically treated patients and 18(62,1%) patients in the mini-open group were undergone at least one of the additional surgical treatments. The mean length of the surgical scar was 3,4(3-5) cm in mini open group. None of the patients complained of the surgical scar. 16 patients in the arthroscopy group and 17 patients in the mini-open group had supraspinatus tendon pathology(either tear or degeneration) in the MRI control at the last follow up. Postoperative pain was present in 1 patient in each group who were classified as bad result. There was no statistically meaningful difference between two groups in terms of clinical or radiological results. In conclusion the arthroscopy assisted mini-open surgery may be a useful tool in hands of training surgeons to prevent ineffective treatment of rotator cuff tears.

  3. Evaluating depressive symptoms in hypomanic and manic episodes using a structured diagnostic tool: validation of a new Mini International Neuropsychiatric Interview (M.I.N.I.) module for the DSM-5 'With Mixed Features' specifier.

    PubMed

    Hergueta, Thierry; Weiller, Emmanuelle

    2013-01-01

    The Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5), includes a new 'With Mixed Features' specifier for mood episodes. In (hypo-)manic episodes, the specifier is given if three or more depressive symptoms are present nearly every day during the episode. A new module of the Mini International Neuropsychiatric Interview (M.I.N.I.) has been developed as a patient-completed questionnaire to evaluate the DSM-5 specifier for (hypo-)manic episodes. The objective of this study was to validate this new module. In Phase I, patients with a manic episode in the past 6 months completed the module and were asked whether the wording was clear, understandable, relevant and specific. Based on their feedback, the module was refined and finalised. In Phase II, psychiatrists each invited five patients to complete the module. The psychiatrists completed record forms for these five patients, which included their diagnoses, made according to DSM-5 criteria during clinical interviewing. The module was validated by comparing depressive symptoms reported by the patients themselves using the M.I.N.I. module with those evaluated by their psychiatrist using DSM-5 criteria during clinical interviewing. In Phase I, a few changes were made to the M.I.N.I. module based on feedback from 20 patients (60% of whom had mixed features). In Phase II, 23 psychiatrists completed record forms for 115 patients, 99 (86.1%) of whom completed the M.I.N.I. module. Agreement between psychiatrists' DSM-5 diagnoses and patients' M.I.N.I. responses was substantial (Cohen's kappa coefficient, 0.60). The overall sensitivity of the M.I.N.I. was 0.91 and its specificity was 0.70. Sensitivity ranged from 0.63 for psychomotor retardation to 0.90 for suicidal thoughts. Specificity ranged from 0.63 for diminished interest/pleasure to 0.90 for suicidal thoughts. The module's positive and negative predictive values were 0.72 and 0.90, respectively. In summary, the M.I.N.I. module demonstrated good concurrent validity with psychiatrists' evaluation of DSM-5 mixed features in manic patients, accurately detecting mixed features with limited risk of over-diagnosis. Due to its simplicity, the M.I.N.I. module could be incorporated into routine psychiatric evaluation of patients with manic episodes. It could also provide a valuable standardised tool for clinical and epidemiological research.

  4. Day and Night Closed-Loop Control Using the Integrated Medtronic Hybrid Closed-Loop System in Type 1 Diabetes at Diabetes Camp.

    PubMed

    Ly, Trang T; Roy, Anirban; Grosman, Benyamin; Shin, John; Campbell, Alex; Monirabbasi, Salman; Liang, Bradley; von Eyben, Rie; Shanmugham, Satya; Clinton, Paula; Buckingham, Bruce A

    2015-07-01

    To evaluate the feasibility and efficacy of a fully integrated hybrid closed-loop (HCL) system (Medtronic MiniMed Inc., Northridge, CA), in day and night closed-loop control in subjects with type 1 diabetes, both in an inpatient setting and during 6 days at diabetes camp. The Medtronic MiniMed HCL system consists of a fourth generation (4S) glucose sensor, a sensor transmitter, and an insulin pump using a modified proportional-integral-derivative (PID) insulin feedback algorithm with safety constraints. Eight subjects were studied over 48 h in an inpatient setting. This was followed by a study of 21 subjects for 6 days at diabetes camp, randomized to either the closed-loop control group using the HCL system or to the group using the Medtronic MiniMed 530G with threshold suspend (control group). The overall mean sensor glucose percent time in range 70-180 mg/dL was similar between the groups (73.1% vs. 69.9%, control vs. HCL, respectively) (P = 0.580). Meter glucose values between 70 and 180 mg/dL were also similar between the groups (73.6% vs. 63.2%, control vs. HCL, respectively) (P = 0.086). The mean absolute relative difference of the 4S sensor was 10.8 ± 10.2%, when compared with plasma glucose values in the inpatient setting, and 12.6 ± 11.0% compared with capillary Bayer CONTOUR NEXT LINK glucose meter values during 6 days at camp. In the first clinical study of this fully integrated system using an investigational PID algorithm, the system did not demonstrate improved glucose control compared with sensor-augmented pump therapy alone. The system demonstrated good connectivity and improved sensor performance. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  5. Zinc-induced modulation of SRSF6 activity alters Bim splicing to promote generation of the most potent apoptotic isoform BimS.

    PubMed

    Hara, Hirokazu; Takeda, Tatsuya; Yamamoto, Nozomi; Furuya, Keisuke; Hirose, Kazuya; Kamiya, Tetsuro; Adachi, Tetsuo

    2013-07-01

    Bim is a member of the pro-apoptotic BH3-only Bcl-2 family of proteins. Bim gene undergoes alternative splicing to produce three predominant splicing variants (BimEL, BimL and BimS). The smallest variant BimS is the most potent inducer of apoptosis. Zinc (Zn(2+)) has been reported to stimulate apoptosis in various cell types. In this study, we examined whether Zn(2+) affects the expression of Bim in human neuroblastoma SH-SY5Y cells. Zn(2+) triggered alterations in Bim splicing and induced preferential generation of BimS, but not BimEL and BimL, in a dose- and time-dependent manner. Other metals (cadmium, cobalt and copper) and stresses (oxidative, endoplasmic reticulum and genotoxic stresses) had little or no effect on the expression of BimS. To address the mechanism of Zn(2+)-induced preferential generation of BimS, which lacks exon 4, we developed a Bim mini-gene construct. Deletion analysis using the Bim mini-gene revealed that predicted binding sites of the SR protein SRSF6, also known as SRp55, are located in the intronic region adjacent to exon 4. We also found that mutations in the predicted SRSF6-binding sites abolished generation of BimS mRNA from the mutated Bim mini-gene. In addition, a UV cross-linking assay followed by Western blotting showed that SRSF6 directly bound to the predicted binding site and Zn(2+) suppressed this binding. Moreover, Zn(2+) stimulated SRSF6 hyper-phosphorylation. TG003, a cdc2-like kinase inhibitor, partially prevented Zn(2+)-induced generation of BimS and SRSF6 hyper-phosphorylation. Taken together, our findings suggest that Zn(2+) inhibits the activity of SRSF6 and promotes elimination of exon 4, leading to preferential generation of BimS. © 2013 FEBS.

  6. Intra-domain phage display (ID-PhD) of peptides and protein mini-domains censored from canonical pIII phage display.

    PubMed

    Tjhung, Katrina F; Deiss, Frédérique; Tran, Jessica; Chou, Ying; Derda, Ratmir

    2015-01-01

    In this paper, we describe multivalent display of peptide and protein sequences typically censored from traditional N-terminal display on protein pIII of filamentous bacteriophage M13. Using site-directed mutagenesis of commercially available M13KE phage cloning vector, we introduced sites that permit efficient cloning using restriction enzymes between domains N1 and N2 of the pIII protein. As infectivity of phage is directly linked to the integrity of the connection between N1 and N2 domains, intra-domain phage display (ID-PhD) allows for simple quality control of the display and the natural variations in the displayed sequences. Additionally, direct linkage to phage propagation allows efficient monitoring of sequence cleavage, providing a convenient system for selection and evolution of protease-susceptible or protease-resistant sequences. As an example of the benefits of such an ID-PhD system, we displayed a negatively charged FLAG sequence, which is known to be post-translationally excised from pIII when displayed on the N-terminus, as well as positively charged sequences which suppress production of phage when displayed on the N-terminus. ID-PhD of FLAG exhibited sub-nanomolar apparent Kd suggesting multivalent nature of the display. A TEV-protease recognition sequence (TEVrs) co-expressed in tandem with FLAG, allowed us to demonstrate that 99.9997% of the phage displayed the FLAG-TEVrs tandem and can be recognized and cleaved by TEV-protease. The residual 0.0003% consisted of phage clones that have excised the insert from their genome. ID-PhD is also amenable to display of protein mini-domains, such as the 33-residue minimized Z-domain of protein A. We show that it is thus possible to use ID-PhD for multivalent display and selection of mini-domain proteins (Affibodies, scFv, etc.).

  7. Implementing the undergraduate mini-CEX: a tailored approach at Southampton University.

    PubMed

    Hill, Faith; Kendall, Kathleen; Galbraith, Kevin; Crossley, Jim

    2009-04-01

    The mini-clinical evaluation exercise (mini-CEX) is widely used in the UK to assess clinical competence, but there is little evidence regarding its implementation in the undergraduate setting. This study aimed to estimate the validity and reliability of the undergraduate mini-CEX and discuss the challenges involved in its implementation. A total of 3499 mini-CEX forms were completed. Validity was assessed by estimating associations between mini-CEX score and a number of external variables, examining the internal structure of the instrument, checking competency domain response rates and profiles against expectations, and by qualitative evaluation of stakeholder interviews. Reliability was evaluated by overall reliability coefficient (R), estimation of the standard error of measurement (SEM), and from stakeholders' perceptions. Variance component analysis examined the contribution of relevant factors to students' scores. Validity was threatened by various confounding variables, including: examiner status; case complexity; attachment specialty; patient gender, and case focus. Factor analysis suggested that competency domains reflect a single latent variable. Maximum reliability can be achieved by aggregating scores over 15 encounters (R = 0.73; 95% confidence interval [CI] +/- 0.28 based on a 6-point assessment scale). Examiner stringency contributed 29% of score variation and student attachment aptitude 13%. Stakeholder interviews revealed staff development needs but the majority perceived the mini-CEX as more reliable and valid than the previous long case. The mini-CEX has good overall utility for assessing aspects of the clinical encounter in an undergraduate setting. Strengths include fidelity, wide sampling, perceived validity, and formative observation and feedback. Reliability is limited by variable examiner stringency, and validity by confounding variables, but these should be viewed within the context of overall assessment strategies.

  8. Identification of Bacteriophage N4 Virion RNA Polymerase-Nucleic Acid Interactions in Transcription Complexes*

    PubMed Central

    Davydova, Elena K.; Kaganman, Irene; Kazmierczak, Krystyna M.; Rothman-Denes, Lucia B.

    2009-01-01

    Bacteriophage N4 mini-virion RNA polymerase (mini-vRNAP), the 1106-amino acid transcriptionally active domain of vRNAP, recognizes single-stranded DNA template-containing promoters composed of conserved sequences and a 3-base loop–5-base pair stem hairpin structure. The major promoter recognition determinants are a purine located at the center of the hairpin loop (–11G) and a base at the hairpin stem (–8G). Mini-vRNAP is an evolutionarily highly diverged member of the T7 family of RNAPs. A two-plasmid system was developed to measure the in vivo activity of mutant mini-vRNAP enzymes. Five mini-vRNAP derivatives, each containing a pair of cysteine residues separated by ∼100 amino acids and single cysteine-containing enzymes, were generated. These reagents were used to determine the smallest catalytically active polypeptide and to map promoter, substrate, and RNA-DNA hybrid contact sites to single amino acid residues in the enzyme by using end-labeled 5-iododeoxyuridine- and azidophenacyl-substituted oligonucleotides, cross-linkable derivatives of the initiating nucleotide, and RNA products with 5-iodouridine incorporated at specific positions. Localization of functionally important amino acid residues in the recently determined crystal structures of apomini-vRNAP and the mini-vRNAP-promoter complex and comparison with the crystal structures of the T7 RNAP initiation and elongation complexes allowed us to predict major rearrangements in mini-vRNAP in the transition from transcription initiation to elongation similar to those observed in T7 RNAP, a task otherwise precluded by the lack of sequence homology between N4 mini-vRNAP and T7 RNAP. PMID:19015264

  9. MD-miniRNA could be a more accurate biomarker for prostate cancer screening compared with serum prostate-specific antigen level.

    PubMed

    Xue, Dong; Zhou, Cui-Xing; Shi, Yun-Bo; Lu, Hao; He, Xiao-Zhou

    2015-05-01

    Prostate cancer and prostatic hyperplasia detection remains a great challenge, lacking of effective non-invasive and specific diagnostic biomarkers. In the current study, we aimed to identify the relative expression of plasma MD-miniRNA and its diagnostic performance in differentiating prostate cancer and prostatic hyperplasia patients from healthy controls, compared with serum prostate-specific antigen (PSA) level. All of the clinical participants (63 prostate cancer patients, 32 prostatic hyperplasia patients, and 50 healthy controls) were obtained from the Third Affiliated Hospital of Suzhou University in China between January 2013 and April 2014. Clinical characteristics were well matched. Plasma samples were extracted to test the relative expression of MD-miniRNA using the method of qRT-PCR. SPSS 22.0 statistical software package was used to analyze the data and GraphPad Prism 6.0 was used to generate the graphs. Relativity expression of plasma MD-miniRNA was significantly upregulated in prostate cancer, compared with prostatic hyperplasia patients and healthy controls. Serum PSA level revealed similar differences among these groups. MD-miniRNA presented a relatively high diagnostic accuracy with AUC of 0.86 (95 % CI 0.80-0.93) in differentiating prostate cancer patients from healthy controls. Simultaneously, MD-miniRNA was able to discriminate prostate cancer patients from prostatic hyperplasia controls with AUC of 0.79 (95 % CI 0.70-0.88). In addition, MD-miniRNA displayed a better diagnostic performance than PSA level. However, the panel of these two biomarkers revealed the best diagnostic performance, compared with either single biomarker. Results of this study showed that plasma MD-miniRNA could serve as a promising and noninvasive biomarker for diagnosing prostate cancer. Further large-scale studies are needed to confirm its clinical diagnosis accuracy.

  10. Mini-interfacial Fracture Toughness of a Multimode Adhesive Bonded to Plasma-treated Dentin.

    PubMed

    Ayres, Ana Paula Almeida; Pongprueksa, Pong; De Munck, Jan; Gré, Cristina Parise; Nascimento, Fábio Dupart; Giannini, Marcelo; Van Meerbeek, Bart

    2017-01-01

    To investigate the bonding efficacy of a multimode adhesive to plasma-treated and -untreated (control) dentin using a mini-interfacial fracture toughness (mini-iFT) test. Twenty human molars were used in a split-tooth design (n = 10). The adhesive Scotchbond Universal (SBU; 3M ESPE) was applied in etch-and-rinse (E&R) and self-etch (SE) modes. Mid-coronal dentin was exposed and covered with a standardized smear layer ground to 320 grit. One half of each dentin surface received 15 s of non-thermal atmospheric plasma (NTAP), while the other half was covered with a metallic barrier and kept untreated. Following the E&R mode, dentin was plasma treated immediately after phosphoric acid etching. SBU and a resin-based composite were applied to dentin following the manufacturer's instructions. Six mini-iFT specimens were prepared per tooth (1.5 x 2.0 x 16 to 18 mm), and a single notch was prepared at the adhesive-dentin interface using a 150-μm diamond blade under water cooling. Half of the mini-iFT specimens were immediately loaded until failure in a 4-point bending test, while the other half were first stored in distilled water for 6 months. After testing, the exact dimensions of the notch were measured with a measuring optical microscope, from which ΚIc was determined. Three-way ANOVA revealed higher mini-iFT for SBU applied in E&R than SE mode for both storage times, irrespective of NTAP treatment. Overall, mini-iFT did not decrease for any of the experimental groups upon 6-month aging, while plasma treatment did not show a direct beneficial effect on mini-iFT of SBU applied in either E&R or SE mode.

  11. Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.

    PubMed

    Gurdan, Z; Szalma, J

    2018-05-01

    Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.

  12. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    PubMed

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores <6.0 completed the study. Agreement between e- and p-versions for the overall score was acceptable (ICC=0.95) with no bias (difference (Delta) p-e=0.1; P=0.21). ICCs for the symptom, activity limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; P<0.0001). The majority of patients (57.5%) preferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  13. A stainless steel bracket for orthodontic application.

    PubMed

    Oh, Keun-Taek; Choo, Sung-Uk; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2005-06-01

    Aesthetics has become an essential element when choosing orthodontic fixed appliances. Most metallic brackets used in orthodontic therapy are made from stainless steel (SS) with the appropriate physical properties and good corrosion resistance, and are available as types 304, 316 and 17-4 PH SS. However, localized corrosion of these materials can frequently occur in the oral environment. This study was undertaken to evaluate the accuracy of sizing, microstructure, hardness, corrosion resistance, frictional resistance and cytotoxicity of commercially available Mini-diamond (S17400), Archist (S30403) and experimentally manufactured SR-50A (S32050) brackets. The size accuracy of Mini-diamond was the highest at all locations except for the external horizontal width of the tie wing (P < 0.05). Micrographs of the Mini-diamond and Archist showed precipitates in the grains and around their boundaries. SR-50A showed the only austenitic phase and the highest polarization resistance of the tested samples. SR-50A also had the highest corrosion resistance [SR-50A, Mini-diamond and Archist were 0.9 x 10(-3), 3.7 x 10(-3), and 7.4 x 10(-3) mm per year (mpy), respectively], in the artificial saliva. The frictional force of SR-50A decreased over time, but that of Mini-diamond and Archist increased. Therefore, SR-50A is believed to have better frictional properties to orthodontic wire than Mini-diamond and Archist. Cytotoxic results showed that the response index of SR-50A was 0/1 (mild), Mini-diamond 1/1 (mild+), and Archist 1/2 (mild+). SR-50A showed greater biocompatibility than either Mini-diamond or Archist. It is concluded that the SR-50A bracket has good frictional property, corrosion resistance and biocompatibility with a lower probability of allergic reaction, compared with conventionally used SS brackets.

  14. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, William; Crewson, Cody; Alexander, Andrew

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimatormore » inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.« less

  15. Identifying applicants suitable to a career in nursing: a value-based approach to undergraduate selection.

    PubMed

    Traynor, Marian; Galanouli, Despina; Roberts, Martin; Leonard, Lawrence; Gale, Thomas

    2017-06-01

    The aim of this study was to complement existing evidence on the suitability of Multiple Mini Interviews as a potential tool for the selection of nursing candidates on to a BSc (Hons) nursing programme. This study aimed to trial the Multiple Mini Interview approach to recruitment with a group of first year nursing students (already selected using traditional interviews). Cross-sectional validation study. This paper reports on the evaluation of the participants' detailed scores from the Multiple Mini Interview stations; their original interview scores and their end of year results. This study took place in March 2015. Scores from the seven Multiple Mini Interview stations were analysed to show the internal structure, reliability and generalizability of the stations. Original selection scores from interviews and in-course assessment were correlated with the MMI scores and variation by students' age, gender and disability status was explored. Reliability of the Multiple Mini Interview score was moderate (G = 0·52). The Multiple Mini Interview score provided better differentiation between more able students than did the original interview score but neither score was correlated with the module results. Multiple Mini Interview scores were positively associated with students' age but not their gender or disability status. The Multiple Mini Interview reported in this study offers a selection process that is based on the values and personal attributes regarded as desirable for a career in nursing and does not necessarily predict academic success. Its moderate reliability indicates the need for further improvement but it is capable of discriminating between candidates and shows little evidence of bias. © 2016 John Wiley & Sons Ltd.

  16. Laser ablation with applied magnetic field for electric propulsion

    NASA Astrophysics Data System (ADS)

    Batishcheva, Alla; Batishchev, Oleg; Cambier, Jean-Luc

    2012-10-01

    Using ultrafast lasers with tera-watt-level power allows efficient ablation and ionization of solid-density materials [1], creating dense and hot (˜100eV) plasma. We propose ablating small droplets in the magnetic nozzle configurations similar to mini-helicon plasma source [2]. Such approach may improve the momentum coupling compared to ablation of solid surfaces and facilitate plasma detachment. Results of 2D modeling of solid wire ablation in the applied magnetic field are presented and discussed. [4pt] [1] O. Batishchev et al, Ultrafast Laser Ablation for Space Propulsion, AIAA technical paper 2008-5294, -16p, 44th JPC, Hartford, 2008.[0pt] [2] O. Batishchev and J.L. Cambier, Experimental Study of the Mini-Helicon Thruster, Air Force Research Laboratory Report, AFRL-RZ-ED-TR-2009-0020, 2009.

  17. On the origin of Hawking mini black-holes and the cold early universe

    NASA Technical Reports Server (NTRS)

    Canuto, V.

    1978-01-01

    A simple argument is outlined leading to the result that the mass of mini black holes exploding today is 10 to the 15th power g. A mathematical model is discussed which indicates that the equation of state is greatly softened in the high-density regime and a phase transition may exist, such that any length (particularly very small sizes) will grow with time irrespective of its relation to the size of the particle horizon. It is shown that the effect of spin-2 mesons with respect to the equation of state is to soften the pressure and make it negative. An analytical expression is given for the probability that any particular region in a hot early universe will evolve into a black hole.

  18. Optimising use of the mini C-arm in foot and ankle surgery.

    PubMed

    Gangopadhyay, Soham; Scammell, Brigitte E

    2009-01-01

    The mini C-arm reduces exposure to ionising radiation compared to the conventional C-arm. Optimising radiation exposure is not only desirable, but also a legal requirement and protocols should be in place to achieve this. Since 2004, all elective foot surgery requiring intraoperative imaging was performed using the mini C-arm. Screening times and radiation doses were recorded for each procedure. Following a learning curve, the screening times stabilised around the median value for the individual procedures. For subtalar or triple arthrodesis this was less than 60 s, for ankle arthrodesis, less than 90 s, for hindfoot arthrodesis using a nail, less than 100 s and for joint injections less than 12 s. Screening time can be used as an audit tool to measure optimum use of the mini C-arm. A protocol is presented including an audit form for every operation where the mini C-arm is used. Radiation protection issues are addressed.

  19. Mini-implants: alternative for oral rehabilitation of a child with ectodermal dysplasia.

    PubMed

    Mello, Bianca Zeponi Fernandes; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Valarelli, Fabrício Pinelli; Oliveira, Thais Marchini

    2015-01-01

    Ectodermal dysplasia is a rare congenital disease that affects several structures of ectodermal origin. The most commonly related oral characteristics are hypodontia, malformed teeth and underdeveloped alveolar ridges. New alternative treatments are needed due to the failure of the conventional prosthesis retention. This case report outlines the oral rehabilitation treatment of a 9-year-old girl with ectodermal dysplasia. The treatment was performed with conventional prosthesis upon mini-implants. The mini-implants provided prosthetic retention. The patient reported a good adaptation of the dental prosthesis and satisfaction with the treatment. The increased self-esteem improved the socialization skills of the girl. In this case report, use of prosthesis with mini-implants was satisfactory for prosthetic retention. However, clinical studies with long-term follow-up are needed to test the mini-implants as an alternative for oral rehabilitation of children with ectodermal dysplasia.

  20. Studies of protein oxidation as a product quality attribute on a scale-down model for cell culture process development.

    PubMed

    Lee, Nacole D; Kondragunta, Bhargavi; Uplekar, Shaunak; Vallejos, Jose; Moreira, Antonio; Rao, Govind

    2015-01-01

    Of importance to the biological properties of proteins produced in cell culture systems are the complex post-translational modifications that are affected by variations in process conditions. Protein oxidation, oxidative modification to intracellular proteins that involves cleavage of the polypeptide chain, and modifications of the amino acid side chains can be affected by such process variations. Dissolved oxygen is a parameter of increasing interest since studies have shown that despite the necessity of oxygen for respiration, there may also be some detrimental effects of oxygen to the cell. Production and accumulation of reactive oxygen species can cause damage to proteins as a result of oxidation of the cell and cellular components. Variation, or changes to cell culture products, can affect function, clearance rate, immunogenicity, and specific activity, which translates into clinical implications. The effect of increasing dissolved oxygen on protein oxidation in immunoglobulin G3-producing mouse hybridoma cells was studied using 50 mL high-throughput mini-bioreactors that employ non-invasive optical sensor technology for monitoring and closed feedback control of pH and dissolved oxygen. Relative protein carbonyl concentration of proteins produced under varying levels of dissolved oxygen was measured by enzyme-linked immunosorbent assay and used as an indicator of oxidative damage. A trend of increasing protein carbonyl content in response to increasing dissolved oxygen levels under controlled conditions was observed. Protein oxidation, oxidative modification to intracellular proteins that involves cleavage of the polypeptide chain, and modifications of the amino acid side chains can be affected by variations in dissolved oxygen levels in cell culture systems. Studies have shown that despite the necessity of oxygen for respiration, there may be detrimental effects of oxygen to the cell. Production and accumulation of reactive oxygen species can cause damage to proteins as a result of oxidation of the cell and cellular components, affecting function, clearance rate, immunogenicity, and specific activity, which translates into clinical implications. The effect of increasing dissolved oxygen on protein oxidation in immunoglobulin G3-producing mouse hybridoma cells was studied using 50 mL high-throughput mini-bioreactors that employ non-invasive optical sensor technology for monitoring and closed feedback control of pH and dissolved oxygen. Protein carbonyl concentration of proteins produced under varying levels of dissolved oxygen was measured by enzyme-linked immunosorbent assay and used as an indicator of oxidative damage. A trend of increasing protein carbonyl content in response to increasing dissolved oxygen levels under controlled conditions was observed. © PDA, Inc. 2015.

  1. A new, ultra-low latency data transmission protocol for Earthquake Early Warning Systems

    NASA Astrophysics Data System (ADS)

    Hill, P.; Hicks, S. P.; McGowan, M.

    2016-12-01

    One measure used to assess the performance of Earthquake Early Warning Systems (EEWS) is the delay time between earthquake origin and issued alert. EEWS latency is dependent on a number of sources (e.g. P-wave propagation, digitisation, transmission, receiver processing, triggering, event declaration). Many regional seismic networks use the SEEDlink protocol; however, packet size is fixed to 512-byte miniSEED records, resulting in transmission latencies of >0.5 s. Data packetisation is seen as one of the main sources of delays in EEWS (Brown et al., 2011). Optimising data-logger and telemetry configurations is a cost-effective strategy to improve EEWS alert times (Behr et al., 2015). Digitisers with smaller, selectable packets can result in faster alerts (Sokos et al., 2016). We propose a new seismic protocol for regional seismic networks benefiting low-latency applications such as EEWS. The protocol, based on Güralp's existing GDI-link format is an efficient and flexible method to exchange data between seismic stations and data centers for a range of network configurations. The main principle is to stream data sample-by-sample instead of fixed-length packets to minimise transmission latency. Self-adaptive packetisation with compression maximises available telemetry bandwidth. Highly flexible metadata fields within GDI-link are compatible with existing miniSEED definitions. Data is sent as integers or floats, supporting a wide range of data formats, including discrete parameters such as Pd & τC for on-site earthquake early warning. Other advantages include: streaming station state-of-health information, instrument control, support of backfilling and fail-over strategies during telemetry outages. Based on tests carried out on the Güralp Minimus data-logger, we show our new protocol can reduce transmission latency to as low as 1 ms. The low-latency protocol is currently being implemented with common processing packages. The results of these tests will help to highlight latency levels that can be achieved with next-generation EEWS.

  2. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  3. The Mini-Economy: Integrating Economics into the Elementary Curriculum.

    ERIC Educational Resources Information Center

    Indiana State Dept. of Education, Indianapolis.

    The focus of this guide is to simulate real world economic activity in the classroom by using a form of economics instruction called a " mini-economy." In a mini-economy, students earn play money in a variety of ways and spend it at a class store or class auction. Students apply for classroom jobs, run businesses, pay taxes, buy rental properties,…

  4. Effects and Implications of Mini-Lectures on Learning in First-Semester General Chemistry

    ERIC Educational Resources Information Center

    Toto, Joe; Booth, Kathy

    2008-01-01

    This study describes the efficacy of a novel tool, mini-lecture movies, in teaching Web based general chemistry. The analysis shows a marked improvement in student learning, as evidenced by a corresponding increase in homework and final exam scores. Students with access to mini-lecture movies scored 11.2% (p = 0.016) higher than students who did…

  5. Sesame and You, Two--A Teacher's Helper: A Revised Guide to Accompany a Videotape Package of Twenty Sesame Street Mini Shows.

    ERIC Educational Resources Information Center

    Sylves, David, Ed.; Sardina, Kathleen, Ed.

    The teaching guide is intended to accompany a videotape package of 20 Sesame Street Mini Shows selected for their relevance to the education of young hearing impaired children. Individually described are segments of each Mini Show in terms of a description, captions, general objective, specific objectives, necessary preteaching, and related…

  6. Case Study: Mini-Case Studies: Small Infusions of Active Learning for Large-Lecture Courses

    ERIC Educational Resources Information Center

    Carloye, Lisa

    2017-01-01

    In this article, the author introduces the usage of case studies to be an excellent method for engaging students through stories. The author notes she developed a series of mini-case studies that can be implemented, with a little advance preparation, within a 10- to 15-minute window during lecture. What makes them "mini" case studies?…

  7. Status of the core and the mini core collections for the U.S. gemrplasm collection of peanut

    USDA-ARS?s Scientific Manuscript database

    To maximize their usefulness, core and mini core collections should be dynamic. The peanut core collection was developed in the early 1990's, and the mini core was developed in the late 1990's. Research has shown that these collections can be used to improve the efficiency and effectiveness of ide...

  8. New York State Occupational Education Mini-Grant Program. 1972 Final Report.

    ERIC Educational Resources Information Center

    Alwell, William

    The mini-grant concept has emerged in recent years as a specific catalyst for the promotion of educational change. A mini-grant is a small grant awarded to an individual (usually a teacher or supervisor) in order that he might investigate or further develop an idea within the classroom or school setting. Developed in the State of New York, this…

  9. Designing a Microhydraulically driven Mini robotic Squid

    DTIC Science & Technology

    2016-05-20

    applications for microrobots include remote monitoring, surveillance, search and rescue, nanoassembly, medicine, and in-vivo surgery . Robotics platforms...Secretary of Defense for Research and Engineering. Designing a Microhydraulically-driven Mini- robotic Squid by Kevin Dehan Meng B.S., U.S. Air...Committee on Graduate Students 2 Designing a Microhydraulically-driven Mini- robotic Squid by Kevin Dehan Meng Submitted to the Department

  10. Embedding Hands-On Mini Laboratory Experiences in a Core Undergraduate Fluid Mechanics Course: A Pilot Study

    ERIC Educational Resources Information Center

    Han, Duanduan; Ugaz, Victor

    2017-01-01

    Three self-contained mini-labs were integrated into a core undergraduate fluid mechanics course, with the goal of delivering hands-on content in a manner scalable to large class sizes. These mini-labs supported learning objectives involving friction loss in pipes, flow measurement, and centrifugal pump analysis. The hands-on experiments were…

  11. The Effects of Teaching a Science Topic in the Regents Living Environment Course in a Mini-Lesson Instructional Environment

    ERIC Educational Resources Information Center

    Barrows, Calder James

    2010-01-01

    This study investigated the effects on high school students' understanding of studying a science topic in the Regents Living Environment course using a Mini-Lesson educational protocol. Mini-Lesson instruction is one of guided instruction, which consists primarily of three sections. First, a brief, focused section in which the teachers explicitly…

  12. Cost analysis of a mini-facet heliostat

    NASA Astrophysics Data System (ADS)

    Hall, Colin; Pratt, Rodney; Farrant, David; Corsi, Clotilde; Pye, John; Coventry, Joe

    2017-06-01

    A significant problem with conventional heliostats is off-axis astigmatism, which increases the spot size at the central receiver, limiting the temperature and efficiency of solar thermal systems. Inspired by low-cost mini-actuators used for car wing mirrors, we examine the economic feasibility of a heliostat with individually adjustable mini-facets to correct astigmatic effects, and we compare three alternative tracking configurations.

  13. Pitfall Traps and Mini-Winkler Extractor as Complementary Methods to Sample Soil Coleoptera.

    PubMed

    Carneiro, A C; Batistella, D A; Battirola, L D; Marques, M I

    2016-02-01

    We compared abundance, species richness, and capture efficiency with pitfall traps and mini-Winkler extractors to examine their use as complementary methods for sampling soil Coleoptera during dry (2010) and high water seasons (2011) in three areas, including inundated and non-inundated regions, in the Pantanal of Poconé, Mato Grosso, Brazil. We paired treatments with two 10 × 10 m plots in inundated and non-inundated locations that were repeated three times in each location for a total of 18 plots. In each plot, we used nine pitfall traps and collected 2 m(2) of leaf litter and surface soil samples with mini-Winkler extractors. We collected a total of 4260 adult beetles comprising 36 families, 113 genera, and 505 species. Most were caught in pitfalls (69%) and the remainder in the mini-Winkler extractors (31%). Each method provided distinct information about the beetle community: 252 species were captured only in pitfall traps, 147 using only the mini-Winkler extractors, and these methods shared another 106 species. Pitfall and mini-Winkler contribute in different ways for the sampling of the soil beetle community, and so they should be considered complementary for a more thorough assessment of community diversity.

  14. Minimally invasive knee arthroplasty: An overview

    PubMed Central

    Tria, Alfred J; Scuderi, Giles R

    2015-01-01

    Minimally invasive surgery (MIS) for arthroplasty of the knee began with surgery for unicondylar knee arthroplasty (UKA). Partial knee replacements were designed in the 1970s and were amenable to a more limited exposure. In the 1990s Repicci popularized the MIS for UKA. Surgeons began to apply his concepts to total knee arthroplasty. Four MIS surgical techniques were developed: quadriceps sparing, mini-mid vastus, mini-subvastus, and mini-medial parapatellar. The quadriceps sparing technique is the most limited one and is also the most difficult. However, it is the least invasive and allows rapid recovery. The mini-midvastus is the most common technique because it affords slightly better exposure and can be extended. The mini-subvastus technique entirely avoids incising the quadriceps extensor mechanism but is time consuming and difficult in the obese and in the muscular male patient. The mini-parapatellar technique is most familiar to surgeons and represents a good starting point for surgeons who are learning the techniques. The surgeries are easier with smaller instruments but can be performed with standard ones. The techniques are accurate and do lead to a more rapid recovery, with less pain, less blood loss, and greater motion if they are appropriately performed. PMID:26601062

  15. Miniature Robotic Spacecraft for Inspecting Other Spacecraft

    NASA Technical Reports Server (NTRS)

    Fredrickson, Steven; Abbott, Larry; Duran, Steve; Goode, Robert; Howard, Nathan; Jochim, David; Rickman, Steve; Straube, Tim; Studak, Bill; Wagenknecht, Jennifer; hide

    2004-01-01

    A report discusses the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam)-- a compact robotic spacecraft intended to be released from a larger spacecraft for exterior visual inspection of the larger spacecraft. The Mini AERCam is a successor to the AERCam Sprint -- a prior miniature robotic inspection spacecraft that was demonstrated in a space-shuttle flight experiment in 1997. The prototype of the Mini AERCam is a demonstration unit having approximately the form and function of a flight system. The Mini AERCam is approximately spherical with a diameter of about 7.5 in. (.19 cm) and a weight of about 10 lb (.4.5 kg), yet it has significant additional capabilities, relative to the 14-in. (36-cm), 35-lb (16-kg) AERCam Sprint. The Mini AERCam includes miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including two digital video cameras and a high-resolution still camera. The Mini AERCam is designed for either remote piloting or supervised autonomous operations, including station keeping and point-to-point maneuvering. The prototype has been tested on an air-bearing table and in a hardware-in-the-loop orbital simulation of the dynamics of maneuvering in proximity to the International Space Station.

  16. An educational video game for nutrition of young people: Theory and design

    PubMed Central

    Ledoux, Tracey; Griffith, Melissa; Thompson, Debbe; Nguyen, Nga; Watson, Kathy; Baranowski, Janice; Buday, Richard; Abdelsamad, Dina; Baranowski, Tom

    2016-01-01

    Background Playing Escape from DIAB (DIAB) and Nanoswarm (NANO), epic video game adventures, increased fruit and vegetable consumption among a multi-ethnic sample of 10–12 year old children during pilot testing. Key elements of both games were educational mini-games embedded in the overall game that promoted knowledge acquisition regarding diet, physical activity and energy balance. 95–100% of participants demonstrated mastery of these mini-games suggesting knowledge acquisition. Aim This article describes the process of designing and developing the educational mini-games. A secondary purpose was to explore the experience of children while playing the games. Method The educational games were based on Social Cognitive and Mastery Learning Theories. A multidisciplinary team of behavioral nutrition, PA, and video game experts designed, developed, and tested the mini-games. Results Alpha testing revealed children generally liked the mini-games and found them to be reasonably challenging. Process evaluation data from pilot testing revealed almost all participants completed nearly all educational mini-games in a reasonable amount of time suggesting feasibility of this approach. Conclusions Future research should continue to explore the use of video games in educating children to achieve healthy behavior changes. PMID:27547019

  17. Quantitative assessment of orthodontic mini-implant displacement: the effect of initial force application.

    PubMed

    Holst, Alexandra Ioana; Karl, Matthias; Karolczak, Marek; Goellner, Matthias; Holst, Stefan

    2010-01-01

    Primary stability and micromovement of orthodontic mini-implants depends on a number of factors and influences clinical success or failure. The purpose of this study was to assess the behavior of orthodontic mini-implants upon initial load application. Orthodontic mini-implants (n = 39) were inserted in the alveolar process of maxillary human cadaver specimens (n = 10). Increasing horizontal forces (up to 2.5 N) were applied, and triggered images were taken in 0.5-N load intervals. Additionally, peri-implant parameters based on micro-CT volume data were recorded. Data were subjected to a two-sided nonparametric Wilcoxon signed rank test, and between-group comparisons were assessed with a Mann-Whitney test (alpha = .05). Initial load application led to displacement beyond elastic recovery of the surrounding bone after force release (P < .001). Cortical thickness and insertion depth, despite numeric differences, did not reveal any statistical differences, while displacement of mini-implants was significantly affected by contact to neighboring teeth (P < .001). Insertion technique and initial load application on orthodontic mini-implants may be regarded as two crucial factors for success, while repeated application of orthodontic force does not seem to increase screw mobility.

  18. An educational video game for nutrition of young people: Theory and design.

    PubMed

    Ledoux, Tracey; Griffith, Melissa; Thompson, Debbe; Nguyen, Nga; Watson, Kathy; Baranowski, Janice; Buday, Richard; Abdelsamad, Dina; Baranowski, Tom

    2016-08-01

    Playing Escape from DIAB (DIAB) and Nanoswarm (NANO) , epic video game adventures, increased fruit and vegetable consumption among a multi-ethnic sample of 10-12 year old children during pilot testing. Key elements of both games were educational mini-games embedded in the overall game that promoted knowledge acquisition regarding diet, physical activity and energy balance. 95-100% of participants demonstrated mastery of these mini-games suggesting knowledge acquisition. This article describes the process of designing and developing the educational mini-games. A secondary purpose was to explore the experience of children while playing the games. The educational games were based on Social Cognitive and Mastery Learning Theories. A multidisciplinary team of behavioral nutrition, PA, and video game experts designed, developed, and tested the mini-games. Alpha testing revealed children generally liked the mini-games and found them to be reasonably challenging. Process evaluation data from pilot testing revealed almost all participants completed nearly all educational mini-games in a reasonable amount of time suggesting feasibility of this approach. Future research should continue to explore the use of video games in educating children to achieve healthy behavior changes.

  19. Silicon micro-fabricated miniature polymer electrolyte fuel cells

    NASA Astrophysics Data System (ADS)

    Kelley, Shawn Christopher

    2000-10-01

    The present thesis relates the design, fabrication, and testing of a unique type of silicon-based, miniature fuel cell. The fuel cell electrodes were constructed using standard silicon micro-fabrication techniques, and were used to construct miniature polymer electrolyte fuel cells (PEFCs) using NafionRTM. During testing, methanol and oxygen were the common reactants, but hydrogen and oxygen could be used as well. A novel form of an electrodeposited Pt:Ru alloy was developed for use as a methanol electrooxidation catalyst in the mini-PEFCs. An optimized mini-PEFC design was developed, tested, and compared with large PEFCs on the basis of performance. Mini-PEFC performance was equivalent to that of large PEFCs when scaled for active-area, but was limited by the function of the oxygen electrode. The rate of methanol crossover in a methanol/oxygen mini-PEFC was predicted using Fick's first law and the electrode chip feed-hole area. It was shown that the present mini-PEFC design could function as a fuel cell material test structure. Additionally, the mini-PEFCs were tested as two-cell stacks and as methanol sensors. The miniature, silicon-based PEFCs developed here successfully incorporate the essential aspects of a large PEFC in a smaller, simpler design.

  20. Nicotine Lozenges in the Relief of Behaviorally Provoked Craving.

    PubMed

    Nides, Mitchell; Shanga, Gilbert Marava; Bishop, Amanda; Becker, William D

    2018-05-01

    Environmental cues may precipitate nicotine cravings in smokers. We present 2 studies exploring the efficacy of nicotine mini lozenges to reduce nicotine craving in smokers following behavioral provocation. Healthy smokers aged ≥18 years enrolled. In Study 1, participants were stratified by number of cigarettes smoked daily; Study 2 enrolled only heavy smokers. After an abstinence period, participants engaged in behavioral provocation to induce nicotine craving before receiving a nicotine mini lozenge (Study 1: 1.5 mg or 4 mg; Study 2: 4 mg) or matching placebo. Craving was assessed using a 100-mm visual analogue scale, and safety was monitored. In Study 1, neither nicotine mini lozenge dose significantly reduced craving in smokers versus placebo. In Study 2, 4-mg nicotine mini lozenges significantly reduced craving scores 5 minutes post-treatment (least-square mean [LSM] change from baseline: -41.8; 95% confidence interval [CI]: -45.8, -37.7) versus placebo (-25.9; 95% CI: -30.0, -21.8; p < .001). Adverse events were infrequent, mild in intensity, and more common with the 4-mg nicotine mini lozenges. Behaviorally provoked nicotine craving can be significantly and safely reduced in heavy/high-dependency smokers with 4-mg nicotine mini lozenges.

  1. Mini AERCam Inspection Robot for Human Space Missions

    NASA Technical Reports Server (NTRS)

    Fredrickson, Steven E.; Duran, Steve; Mitchell, Jennifer D.

    2004-01-01

    The Engineering Directorate of NASA Johnson Space Center has developed a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam free flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35 pound, 14 inch AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations including automatic stationkeeping and point-to-point maneuvering. Mini AERCam is designed to fulfill the unique requirements and constraints associated with using a free flyer to perform external inspections and remote viewing of human spacecraft operations. This paper describes the application of Mini AERCam for stand-alone spacecraft inspection, as well as for roles on teams of humans and robots conducting future space exploration missions.

  2. Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems

    DTIC Science & Technology

    2017-04-13

    modelling code, a parallel benchmark , and a communication avoiding version of the QR algorithm. Further, several improvements to the OmpSs model were...movement; and a port of the dynamic load balancing library to OmpSs. Finally, several updates to the tools infrastructure were accomplished, including: an...OmpSs: a basic algorithm on image processing applications, a mini application representative of an ocean modelling code, a parallel benchmark , and a

  3. Physiological actions of preservative agents: prospective of use of modern microbiological techniques in assessing microbial behaviour in food preservation.

    PubMed

    Brul, Stanley; Coote, Peter; Oomes, Suus; Mensonides, Femke; Hellingwerf, Klaas; Klis, Frans

    2002-11-15

    In this mini-review, various aspects of homeostasis of microbial cells and its perturbation by antimicrobial agents will be discussed. First, outlining the position that the physiological studies on microbial behaviour using the modern molecular tools should have in food science sets the scene for the studies. Subsequently, the advent of functional genomics is discussed that allows full coverage of cellular reactions at unprecedented levels. Examples of weak organic acid resistance, the stress response against natural antimicrobial agents and responses against physicochemical factors show how we can now "open the black box" that microbes are, look inside and begin to understand how different cellular signalling cables are wired together. Using the analogy with machines, it will be indicated how the use of various signalling systems depends on the availability of substrates "fuel" to let the systems act in the context of the minimum energetic requirement cells have to let their housekeeping systems run. The outlook illustrates how new insights might be used to device knowledge-based rather than empirical combinations of preservation systems and how risk assessment models might be deviced that link the mechanistic insight to risk distributions of events in food manufacturing.

  4. Extreme Events: low and high total ozone over Arosa, Switzerland

    NASA Astrophysics Data System (ADS)

    Rieder, H. E.; Staehelin, J.; Maeder, J. A.; Ribatet, M.; Stübi, R.; Weihs, P.; Holawe, F.; Peter, T.; Davison, A. C.

    2009-04-01

    The frequency distribution of days with extreme low (termed ELOs) and high (termed EHOs) total ozone is analyzed for the world's longest total ozone record (Arosa, Switzerland - for details see Staehelin et al.,1998a,b), with new tools from extreme value theory (e.g. Coles, 2001; Ribatet, 2007). A heavy-tail focused approach is used through the fitting of the Generalized Pareto Distribution (GPD) to the Arosa time series. Asymptotic arguments (Pickands, 1975) justify the use of the GPD for modeling exceedances over a high (or below a low) enough threshold (Coles, 2001). The analysis shows that the GPD is appropriate for modeling the frequency distribution in total ozone above or below a mathematically well-defined threshold. While previous studies focused on so termed ozone mini-holes and mini-highs (e.g. Bojkov and Balis, 2001, Koch et al., 2005), this study is the first to present a mathematical description of extreme events in low and high total ozone for a northern mid-latitudes site (Rieder et al., 2009). The results show (a) an increase in days with extreme low (ELOs) and (b) a decrease in days with extreme high total ozone (EHOs) during the last decades, (c) that the general trend in total ozone is strongly determined by these extreme events and (d) that fitting the GPD is an appropriate method for the estimation of the frequency distribution of so-called ozone mini-holes. Furthermore, this concept allows one to separate the effect of Arctic ozone depletion from that of in situ mid-latitude ozone loss. As shown by this study, ELOs and EHOs have a strong influence on mean values in total ozone and the "extremes concept" could be further used also for validation of Chemistry-Climate-Models (CCMs) within the scientific community. References: Bojkov, R. D., and Balis, D.S.: Characteristics of episodes with extremely low ozone values in the northern middle latitudes 1975-2000, Ann. Geophys., 19, 797-807, 2001. Coles, S.: An Introduction to Statistical Modeling of Extreme Values, Springer Series in Statistics, ISBN:1852334592, Springer, Berlin, 2001. Koch, G., H. Wernli, C. Schwierz, J. Staehelin, and T. Peter (2005), A composite study on the structure and formation of ozone miniholes and minihighs over central Europe, Geophys. Res. Lett., 32, L12810, doi:10.1029/2004GL022062. Pickands, J.: Statistical-Inference using extreme order Statistics, Ann. Stat., 3, 1, 119-131, 1975. Ribatet, M.: POT: Modelling peaks over a threshold, R News, 7, 34-36, 2007. Rieder, H.E., Staehelin, J., Maeder, J.A., Ribatet, M., Stübi, R., Weihs, P., Holawe, F., Peter, T., and Davison, A.C.: From ozone mini holes and mini highs towards extreme value theory: New insights from extreme events and non stationarity, submitted to J. Geophys. Res., 2009. Staehelin, J., Kegel, R., and Harris, N. R.: Trend analysis of the homogenized total ozone series of Arosa (Switzerland), 1929-1996, J. Geophys. Res., 103(D7), 8389-8400, doi:10.1029/97JD03650, 1998a. Staehelin, J., Renaud, A., Bader, J., McPeters, R., Viatte, P., Hoegger, B., Bugnion, V., Giroud, M., and Schill, H.: Total ozone series at Arosa (Switzerland): Homogenization and data comparison, J. Geophys. Res., 103(D5), 5827-5842, doi:10.1029/97JD02402, 1998b.

  5. A DISTANT RADIO MINI-HALO IN THE PHOENIX GALAXY CLUSTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Weeren, R. J.; Andrade-Santos, F.; Forman, W. R.

    We report the discovery of extended radio emission in the Phoenix cluster (SPT-CL J2344-4243, z = 0.596) with the Giant Metrewave Radio Telescope (GMRT) at 610 MHz. The diffuse emission extends over a region of at least 400-500 kpc and surrounds the central radio source of the Brightest Cluster Galaxy, but does not appear to be directly associated with it. We classify the diffuse emission as a radio mini-halo, making it the currently most distant mini-halo known. Radio mini-halos have been explained by synchrotron emitting particles re-accelerated via turbulence, possibly induced by gas sloshing generated from a minor merger event. Chandra observationsmore » show a non-concentric X-ray surface brightness distribution, which is consistent with this sloshing interpretation. The mini-halo has a flux density of 17 ± 5 mJy, resulting in a 1.4 GHz radio power of (10.4 ± 3.5) × 10{sup 24} W Hz{sup –1}. The combined cluster emission, which includes the central compact radio source, is also detected in a shallow GMRT 156 MHz observation and together with the 610 MHz data we compute a spectral index of –0.84 ± 0.12 for the overall cluster radio emission. Given that mini-halos typically have steeper radio spectra than cluster radio galaxies, this spectral index should be taken as an upper limit for the mini-halo.« less

  6. A mini-microscope for in situ monitoring of cells.

    PubMed

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  7. A mini-microscope for in situ monitoring of cells†‡

    PubMed Central

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  8. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    PubMed

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  9. Evaluation of the NICE mini-GRACE risk scores for acute myocardial infarction using the Myocardial Ischaemia National Audit Project (MINAP) 2003-2009: National Institute for Cardiovascular Outcomes Research (NICOR).

    PubMed

    Simms, Alexander D; Reynolds, Stephanie; Pieper, Karen; Baxter, Paul D; Cattle, Brian A; Batin, Phillip D; Wilson, John I; Deanfield, John E; West, Robert M; Fox, Keith A A; Hall, Alistair S; Gale, Christopher P

    2013-01-01

    To evaluate the performance of the National Institute for Health and Clinical Excellence (NICE) mini-Global Registry of Acute Coronary Events (GRACE) (MG) and adjusted mini-GRACE (AMG) risk scores. Retrospective observational study. 215 acute hospitals in England and Wales. 137 084 patients discharged from hospital with a diagnosis of acute myocardial infarction (AMI) between 2003 and 2009, as recorded in the Myocardial Ischaemia National Audit Project (MINAP). Model performance indices of calibration accuracy, discriminative and explanatory performance, including net reclassification index (NRI) and integrated discrimination improvement. Of 495 263 index patients hospitalised with AMI, there were 53 196 ST elevation myocardial infarction and 83 888 non-ST elevation myocardial infarction (NSTEMI) (27.7%) cases with complete data for all AMG variables. For AMI, AMG calibration was better than MG calibration (Hosmer-Lemeshow goodness of fit test: p=0.33 vs p<0.05). MG and AMG predictive accuracy and discriminative ability were good (Brier score: 0.10 vs 0.09; C statistic: 0.82 and 0.84, respectively). The NRI of AMG over MG was 8.1% (p<0.05). Model performance was reduced in patients with NSTEMI, chronic heart failure, chronic renal failure and in patients aged ≥85 years. The AMG and MG risk scores, utilised by NICE, demonstrated good performance across a range of indices using MINAP data, but performed less well in higher risk subgroups. Although indices were better for AMG, its application may be constrained by missing predictors.

  10. Translational Mini-Review Series on Complement Factor H: Structural and functional correlations for factor H

    PubMed Central

    Schmidt, C Q; Herbert, A P; Hocking, H G; Uhrín, D; Barlow, P N

    2008-01-01

    The 155-kDa glycoprotein, complement factor H (CFH), is a regulator of complement activation that is abundant in human plasma. Three-dimensional structures of over half the 20 complement control protein (CCP) modules in CFH have been solved in the context of single-, double- and triple-module segments. Proven binding sites for C3b occupy the N and C termini of this elongated molecule and may be brought together by a bend in CFH mediated by its central CCP modules. The C-terminal CCP 20 is key to the ability of the molecule to adhere to polyanionic markers on self-surfaces where CFH acts to regulate amplification of the alternative pathway of complement. The surface patch on CCP 20 that binds to model glycosaminoglycans has been mapped using nuclear magnetic resonance (NMR), as has a second glycosaminoglycan-binding patch on CCP 7. These patches include many of the residue positions at which sequence variations have been linked to three complement-mediated disorders: dense deposit disease, age-related macular degeneration and atypical haemolytic uraemic syndrome. In one plausible model, CCP 20 anchors CFH to self-surfaces via a C3b/polyanion composite binding site, CCP 7 acts as a ‘proof-reader’ to help discriminate self- from non-self patterns of sulphation, and CCPs 1–4 disrupt C3/C5 convertase formation and stability. PMID:18081691

  11. CFS-SMO based classification of breast density using multiple texture models.

    PubMed

    Sharma, Vipul; Singh, Sukhwinder

    2014-06-01

    It is highly acknowledged in the medical profession that density of breast tissue is a major cause for the growth of breast cancer. Increased breast density was found to be linked with an increased risk of breast cancer growth, as high density makes it difficult for radiologists to see an abnormality which leads to false negative results. Therefore, there is need for the development of highly efficient techniques for breast tissue classification based on density. This paper presents a hybrid scheme for classification of fatty and dense mammograms using correlation-based feature selection (CFS) and sequential minimal optimization (SMO). In this work, texture analysis is done on a region of interest selected from the mammogram. Various texture models have been used to quantify the texture of parenchymal patterns of breast. To reduce the dimensionality and to identify the features which differentiate between breast tissue densities, CFS is used. Finally, classification is performed using SMO. The performance is evaluated using 322 images of mini-MIAS database. Highest accuracy of 96.46% is obtained for two-class problem (fatty and dense) using proposed approach. Performance of selected features by CFS is also evaluated by Naïve Bayes, Multilayer Perceptron, RBF Network, J48 and kNN classifier. The proposed CFS-SMO method outperforms all other classifiers giving a sensitivity of 100%. This makes it suitable to be taken as a second opinion in classifying breast tissue density.

  12. A new synthetic granular calcium phosphate compound induces new bone in a sinus lift rabbit model.

    PubMed

    Trbakovic, Amela; Hedenqvist, Patricia; Mellgren, Torbjörn; Ley, Cecilia; Hilborn, Jöns; Ossipov, Dmitri; Ekman, Stina; Johansson, Carina B; Jensen-Waern, Marianne; Thor, Andreas

    2018-03-01

    The aim of this study was to investigate if a synthetic granular calcium phosphate compound (CPC) and a composite bisphosphonate-linked hyaluronic acid-calcium phosphate hydrogel (HABP·CaP) induced similar or more amount of bone as bovine mineral in a modified sinus lift rabbit model. Eighteen adult male New Zeeland White rabbits, received randomly one of the two test materials on a random side of the face, and bovine mineral as control on the contralateral side. In a sinus lift, the sinus mucosa was elevated and a titanium mini-implant was placed in the alveolar bone. Augmentation material (CPC, HABP·CaP or bovine bone) was applied in the space around the implant. The rabbits were euthanized three months after surgery and qualitative and histomorphometric evaluation were conducted. Histomorphometric evaluation included three different regions of interest (ROIs) and the bone to implant contact on each installed implant. Qualitative assessment (p = <.05), histomorphometric evaluations (p = < .01), and implant incorporation (p = <.05) showed that CPC and bovine mineral induced similar amount of bone and more than the HABP·CaP hydrogel. CPC induced similar amount of bone as bovine mineral and both materials induced more bone than HABP·CaP hydrogel. The CPC is suggested as a synthetic alternative for augmentations in the maxillofacial area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Plasma homocysteine and cerebral small vessel disease as possible mediators between kidney and cognitive functions in patients with diabetes mellitus.

    PubMed

    Sonoda, Mika; Shoji, Tetsuo; Kuwamura, Yukinobu; Okute, Yujiro; Naganuma, Toshihide; Shima, Hideaki; Motoyama, Koka; Morioka, Tomoaki; Mori, Katsuhito; Fukumoto, Shinya; Shioi, Atsushi; Shimono, Taro; Fujii, Hisako; Kabata, Daijiro; Shintani, Ayumi; Emoto, Masanori; Inaba, Masaaki

    2017-06-29

    Cognitive impairment is more prevalent in those with decreased kidney function. We tested a hypothesis that an increased homocysteine and/or cerebral small vessel diseases (SVDs) mediate the link between kidney and cognitive functions in a cross-sectional study in 143 type 2 diabetes patients without diagnosis of dementia or prior stroke. The exposure and outcome variables were estimated glomerular filtration rate (eGFR) and cognitive performance evaluated with Modified Mini-Mental State (3 MS) examination, respectively. The candidate mediators were plasma homocysteine concentration, and SVDs including silent cerebral infarction, cerebral microbleed, periventricular hyperintensity, and deep and subcortical white matter hyperintensity by magnetic resonance imaging. In multiple regression models adjusted for 12 potential confounders, eGFR was positively associated with 3 MS score, inversely with homocysteine, but not significantly with the presence of any type of SVD. The association of eGFR with 3 MS remained significant when each of the SVDs was added to the model, whereas it disappeared when homocysteine was included in place of SVD. Mediation analysis indicated nearly significant mediation of homocysteine (P = 0.062) but no meaningful mediations of SVDs (P = 0.842-0.930). Thus, homocysteine, not SVDs, was shown to be the possible mediator between kidney and cognitive functions in patients with type 2 diabetes mellitus.

  14. Integrated modeling and analysis of a space-truss article

    NASA Technical Reports Server (NTRS)

    Stockwell, Alan E.; Perez, Sharon E.; Pappa, Richard S.

    1990-01-01

    MSC/NASTRAN is being used in the Controls-Structures Interaction (CSI) program at NASA Langley Research Center as a key analytical tool for structural analysis as well as the basis for control law development, closed-loop performance evaluation, and system safety checks. Guest investigators from academia and industry are performing dynamics and control experiments on a flight-like deployable space truss called Mini-Mast to determine the effectiveness of various active-vibration control laws. MSC/NASTRAN was used to calculate natural frequencies and mode shapes below 100 Hz to describe the dynamics of the 20-meter-long lightweight Mini-Mast structure. Gravitational effects contribute significantly to structural stiffness and are accounted for through a two-phase solution in which the differential stiffness matrix is calculated and then used in the eigensolution. Reduced modal models are extracted for control law design and evaluation of closed-loop system performance. Predicted actuator forces from controls simulations are then applied to the extended model to predict member loads and stresses. These pre-test analyses reduce risks associated with the structural integrity of the test article, which is a major concern in closed-loop control experiments due to potential instabilities.

  15. 3D virtual environment of Taman Mini Indonesia Indah in a web

    NASA Astrophysics Data System (ADS)

    Wardijono, B. A.; Wardhani, I. P.; Chandra, Y. I.; Pamungkas, B. U. G.

    2018-05-01

    Taman Mini Indonesia Indah known as TMII is a largest recreational park based on culture in Indonesia. This park has 250 acres that consist of houses from provinces in Indonesia. In TMII, there are traditional houses of the various provinces in Indonesia. The official website of TMII has informed the traditional houses, but the information was limited to public. To provide information more detail about TMII to the public, this research aims to create and develop virtual traditional houses as 3d graphics models and show it via website. The Virtual Reality (VR) technology was used to display the visualization of the TMII and the surrounding environment. This research used Blender software to create the 3D models and Unity3D software to make virtual reality models that can be showed on a web. This research has successfully created 33 virtual traditional houses of province in Indonesia. The texture of traditional house was taken from original to make the culture house realistic. The result of this research was the website of TMII including virtual culture houses that can be displayed through the web browser. The website consists of virtual environment scenes and internet user can walkthrough and navigates inside the scenes.

  16. Cryogenic Thermal Management Advances during the CRYOTOOL Program

    NASA Astrophysics Data System (ADS)

    Bugby, D.; Stouffer, C.; Garzon, J.; Beres, M.; Gilchrist, A.; Roberts, T.; Davis, T.

    2006-04-01

    This paper describes the cryogenic thermal management advances made during the AFRL-sponsored CRYOTOOL program. Advances occurred as a result of conducting four technology development tasks: (1) development of a differential thermal expansion cryogenic thermal switch (DTE-CTSW) made with high purity Al end-pieces and an Ultem support rod; (2) carrying out of a dual DTE-CTSW/dual cryocooler performance test to quantify CTSW benefits in a redundant cryocooler system; (3) development of a miniaturized cryogenic loop heat pipe (mini-CLHP) that combines flex link, conduction bar, and CTSW functionalities; and (4) development of an across-gimbal cryogenic thermal transport system (GCTTS) with large diameter transport line coils for optics cooling. The results are as follows. The DTE-CTSW achieved an ON conductance of 2-3.6 W/K (from 35-90 K) and an OFF resistance of 1100-2300 K/W (300-230 K warm end). The redundant cryocooler test showed modest parasitic heat leak savings when dual DTE-CTSWs were used versus when they were not used. The mini-CLHP, using neon as the working fluid, transported 2.5 W at 35 K, achieved an OFF resistance of 1555 K/W, and had cross/axial flexibilities of 100-450 N/m. Lastly, GCTTS, using nitrogen as the working fluid, transported 20 W at 100 K in a flat configuration. Additional work is needed to verify GCTTS operation in an elevated orientation.

  17. Calpain cleavage within dysferlin exon 40a releases a synaptotagmin-like module for membrane repair

    PubMed Central

    Redpath, G. M. I.; Woolger, N.; Piper, A. K.; Lemckert, F. A.; Lek, A.; Greer, P. A.; North, K. N.; Cooper, S. T.

    2014-01-01

    Dysferlin and calpain are important mediators of the emergency response to repair plasma membrane injury. Our previous research revealed that membrane injury induces cleavage of dysferlin to release a synaptotagmin-like C-terminal module we termed mini-dysferlinC72. Here we show that injury-activated cleavage of dysferlin is mediated by the ubiquitous calpains via a cleavage motif encoded by alternately spliced exon 40a. An exon 40a–specific antibody recognizing cleaved mini-dysferlinC72 intensely labels the circumference of injury sites, supporting a key role for dysferlinExon40a isoforms in membrane repair and consistent with our evidence suggesting that the calpain-cleaved C-terminal module is the form specifically recruited to injury sites. Calpain cleavage of dysferlin is a ubiquitous response to membrane injury in multiple cell lineages and occurs independently of the membrane repair protein MG53. Our study links calpain and dysferlin in the calcium-activated vesicle fusion of membrane repair, placing calpains as upstream mediators of a membrane repair cascade that elicits cleaved dysferlin as an effector. Of importance, we reveal that myoferlin and otoferlin are also cleaved enzymatically to release similar C-terminal modules, bearing two C2 domains and a transmembrane domain. Evolutionary preservation of this feature highlights its functional importance and suggests that this highly conserved C-terminal region of ferlins represents a functionally specialized vesicle fusion module. PMID:25143396

  18. Exploring the "Obesity Paradox" as a Correlate of Cognitive and Physical Function in Community-dwelling Black and White Older Adults.

    PubMed

    Skinner, Jeannine S; Abel, Willie Mae; McCoy, Katryna; Wilkins, Consuelo H

    2017-01-01

    The obesity paradox has been documented in aged populations, yet it remains unclear if this paradox persists for physical and cognitive outcomes in community-dwelling older adult populations. Our study examines associations between body mass index (BMI) classification, cognitive function, and physical function. We also investigate whether these associations are modified by race or age. Cross-sectional study. Senior residential sites and community centers in Saint Louis, Missouri. Study participants included 331 adults, aged >55 years. Age was stratified into young-old (aged 55-74 years) and older (aged ≥75 years). Physical function was measured using the mini-Physical Performance Test (mini-PPT) and grip strength. Cognitive function was assessed with the Short Blessed Test (SBT) and the Trail Making Tests (TMT-A and TMT-B) performance. Older adults who were obese had significantly better cognitive flexibility (TMT-B) performance than normal weight older adults (P=.02), and this association was not influenced by age or race. Adiposity was not associated with psychomotor speed (TMT-A), general cognition (SBT), or measures of physical function (Ps>.05). In a diverse sample of community-dwelling older adults, we found partial support for the controversial obesity paradox. Our results suggest excess adiposity may be protective for executive function processes. Future research is needed to examine the underlying physiological processes linking adiposity to executive function in older adults.

  19. Can Multiple Mini-Interviews Predict Academic Performance of Dental Students? A Two-Year Follow-Up.

    PubMed

    Alaki, Sumer M; Yamany, Ibrahim A; Shinawi, Lana A; Hassan, Mona H A; Tekian, Ara

    2016-11-01

    Prior research has shown that students' previous grade point average (GPA) is the best predictor for future academic success. However, it can only partly predict the variability in dental school performance. The aim of this study was to assess the predictive value of multiple mini-interviews (MMI) as an admission criterion by comparing them with the academic performance of dental students over a two-year period. All incoming undergraduate dental students at the King Abdulaziz University Faculty of Dentistry (KAUFD) during academic year 2013-14 were invited to participate in MMI. Students rotated through six objective structured clinical exam (OSCE)-like stations for 30 minutes total and were interviewed by two trained faculty interviewers at each station. The stations were focused on noncognitive skills thought to be essential to academic performance at KAUFD. The academic performance of these students was then followed for two years and linked to their MMI scores. A total of 146 students (71 males and 75 females) participated in an interview (response rate=92.9%). Most students scored in the acceptable range at each MMI station. Students' total MMI score, ambitions, and motives were significant predictors of GPA during the two years of follow-up (p<0.038 and p<0.001, respectively). In this study, MMI was found to be able to predict future academic performance of undergraduate dental students.

  20. High-Resolution Chirp and Mini-Sparker Seismic-Reflection Data From the Southern California Continental Shelf - Gaviota to Mugu Canyon

    USGS Publications Warehouse

    Sliter, Ray W.; Triezenberg, Peter J.; Hart, Patrick E.; Draut, Amy E.; Normark, William R.; Conrad, James E.

    2008-01-01

    The U.S. Geological Survey (USGS) collected high-resolution shallow seismic-reflection data in September, 2007, and June-July, 2008, from the continental shelf offshore of southern California between Gaviota and Mugu Canyon, in support of the California's State Waters Mapping Program. Data were acquired using SIG 2mille mini-sparker and Edgetech chirp 512 instruments aboard the R/V Zephyr (Sept. 2007) and R/V Parke Snavely (June-July 2008). The survey area spanned approximately 120 km of coastline, and included shore-perpendicular transects spaced 1.0-1.5 km apart that extended offshore to at least the 3-mile limit of State waters, in water depths ranging from 10 m near shore to 300 m near the offshore extent of Mugu and Hueneme submarine canyons. Subbottom acoustic penetration spanned tens to several hundred meters, variable by location. This report includes maps of the surveyed transects, linked to Google Earth software, as well as digital data files showing images of each transect in SEG-Y, JPEG, and TIFF formats. The images of sediment deposits, tectonic structure, and natural-gas seeps collected during this study provide geologic information that is essential to coastal zone and resource management at Federal, State and local levels, as well as to future research on the sedimentary, tectonic, and climatic record of southern California.

Top