Physical activity and body image among men and boys: A meta-analysis.
Bassett-Gunter, Rebecca; McEwan, Desmond; Kamarhie, Aria
2017-09-01
Three meta-analytic reviews have concluded that physical activity is positively related to body image. Historically, research regarding physical activity and body image has been disproportionately focused on female samples. For example, the most recent meta-analysis (2009) extracted 56 effect sizes for women and only 12 for men. The current paper provides an update to the literature regarding the relationship between physical activity and body image among men and boys across 84 individual effect sizes. The analysis also provides insight regarding moderator variables including participant age, and physical activity type and intensity. Overall, physical activity was positively related to body image among men and boys with various moderator variables warranting further investigation. Pragmatic implications are discussed as well as the limitations within existing research and need for additional research to further understand moderator and mediator variables. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hausenblas, Heather A; Campbell, Anna; Menzel, Jessie E; Doughty, Jessica; Levine, Michael; Thompson, J Kevin
2013-02-01
Older meta-analyses of the effects of the media's portrayal of the ideal physique have found small effects revealing that exposure to the ideal physique increases body image concerns. These meta-analyses also included correlational, quasi-experimental, and experimental studies, with limited examination of moderators and other relevant outcomes besides body image. We conducted a systematic literature search and identified 33 experimental (i.e., pre and post data for both experimental and control groups) laboratory studies examining the effects of acute exposure to the media's portrayal of the ideal physique on eating disorder symptoms (i.e., body image, positive affect, negative affect, self-esteem, anger, anxiety and depression) and the mechanisms that moderate this effect. Fourteen separate meta-analyses revealed a range of small to moderate effect sizes for change in outcomes from pre to post for both experimental and control groups. Exposure to images of the ideal physique resulted in small effect sizes for increased depression and anger and decreased self-esteem and positive affect. Moderator analyses revealed moderate effect sizes for increased depression and body dissatisfaction among high-risk participants. This meta-analysis makes it clear that media exposure of the ideal physique results in small changes in eating disorder symptoms, particularly with participants at high risk for developing an eating disorder. Further research is needed to examine the longitudinal effects of media exposure of eating disorder symptoms. Copyright © 2012 Elsevier Ltd. All rights reserved.
Grabe, Shelly; Ward, L Monique; Hyde, Janet Shibley
2008-05-01
Research suggests that exposure to mass media depicting the thin-ideal body may be linked to body image disturbance in women. This meta-analysis examined experimental and correlational studies testing the links between media exposure to women's body dissatisfaction, internalization of the thin ideal, and eating behaviors and beliefs with a sample of 77 studies that yielded 141 effect sizes. The mean effect sizes were small to moderate (ds = -.28, -.39, and -.30, respectively). Effects for some outcome variables were moderated by publication year and study design. The findings support the notion that exposure to media images depicting the thin-ideal body is related to body image concerns for women. (Copyright) 2008 APA, all rights reserved.
Scaling Properties of Circulation in Moderate-Reynolds-Number Turbulent Wakes
NASA Astrophysics Data System (ADS)
Sreenivasan, K. R.; Juneja, A.; Suri, A. K.
1995-07-01
Circulation around closed contours (square boxes) of various sizes is computed from two-dimensional spatial velocity data, acquired by the particle image velocimetry technique in the turbulent wake behind a circular cylinder. Scaling is observed for an intermediate range of box sizes even at the low and moderate Reynolds numbers of measurement. The scaling exponents are determined at various Reynolds numbers and presented with a plausible interpretation.
Granberg, Ellen M.; Simons, Leslie Gordon; Simons, Ronald L.
2009-01-01
Social psychologists have amassed a large body of work demonstrating that overweight African American adolescent girls have generally positive self-images, particularly when compared with overweight females from other racial and ethnic groups. Some scholars have proposed that elements of African American social experience may contribute to the maintenance of these positive self-views. In this paper, we evaluate these arguments using data drawn from a panel study of socio-economically diverse African American adolescent girls living in Iowa and Georgia. We analyze the relationship between body size and social self-image over three waves of data, starting when the girls were 10 years of age and concluding when they were approximately 14. We find that heavier respondents hold less positive social self-images but also find that being raised in a family that practices racial socialization moderates this relationship. PMID:20161575
Diedrichs, Phillippa C; Lee, Christina
2010-06-01
Increasing body size and shape diversity in media imagery may promote positive body image. While research has largely focused on female models and women's body image, men may also be affected by unrealistic images. We examined the impact of average-size and muscular male fashion models on men's and women's body image and perceived advertisement effectiveness. A sample of 330 men and 289 women viewed one of four advertisement conditions: no models, muscular, average-slim or average-large models. Men and women rated average-size models as equally effective in advertisements as muscular models. For men, exposure to average-size models was associated with more positive body image in comparison to viewing no models, but no difference was found in comparison to muscular models. Similar results were found for women. Internalisation of beauty ideals did not moderate these effects. These findings suggest that average-size male models can promote positive body image and appeal to consumers. 2010 Elsevier Ltd. All rights reserved.
Time-Series Analysis of Supergranule Characterstics at Solar Minimum
NASA Technical Reports Server (NTRS)
Williams, Peter E.; Pesnell, W. Dean
2013-01-01
Sixty days of Doppler images from the Solar and Heliospheric Observatory (SOHO) / Michelson Doppler Imager (MDI) investigation during the 1996 and 2008 solar minima have been analyzed to show that certain supergranule characteristics (size, size range, and horizontal velocity) exhibit fluctuations of three to five days. Cross-correlating parameters showed a good, positive correlation between supergranulation size and size range, and a moderate, negative correlation between size range and velocity. The size and velocity do exhibit a moderate, negative correlation, but with a small time lag (less than 12 hours). Supergranule sizes during five days of co-temporal data from MDI and the Solar Dynamics Observatory (SDO) / Helioseismic Magnetic Imager (HMI) exhibit similar fluctuations with a high level of correlation between them. This verifies the solar origin of the fluctuations, which cannot be caused by instrumental artifacts according to these observations. Similar fluctuations are also observed in data simulations that model the evolution of the MDI Doppler pattern over a 60-day period. Correlations between the supergranule size and size range time-series derived from the simulated data are similar to those seen in MDI data. A simple toy-model using cumulative, uncorrelated exponential growth and decay patterns at random emergence times produces a time-series similar to the data simulations. The qualitative similarities between the simulated and the observed time-series suggest that the fluctuations arise from stochastic processes occurring within the solar convection zone. This behavior, propagating to surface manifestations of supergranulation, may assist our understanding of magnetic-field-line advection, evolution, and interaction.
A Meta-Analytic Review of Stand-Alone Interventions to Improve Body Image
Alleva, Jessica M.; Sheeran, Paschal; Webb, Thomas L.; Martijn, Carolien; Miles, Eleanor
2015-01-01
Objective Numerous stand-alone interventions to improve body image have been developed. The present review used meta-analysis to estimate the effectiveness of such interventions, and to identify the specific change techniques that lead to improvement in body image. Methods The inclusion criteria were that (a) the intervention was stand-alone (i.e., solely focused on improving body image), (b) a control group was used, (c) participants were randomly assigned to conditions, and (d) at least one pretest and one posttest measure of body image was taken. Effect sizes were meta-analysed and moderator analyses were conducted. A taxonomy of 48 change techniques used in interventions targeted at body image was developed; all interventions were coded using this taxonomy. Results The literature search identified 62 tests of interventions (N = 3,846). Interventions produced a small-to-medium improvement in body image (d + = 0.38), a small-to-medium reduction in beauty ideal internalisation (d + = -0.37), and a large reduction in social comparison tendencies (d + = -0.72). However, the effect size for body image was inflated by bias both within and across studies, and was reliable but of small magnitude once corrections for bias were applied. Effect sizes for the other outcomes were no longer reliable once corrections for bias were applied. Several features of the sample, intervention, and methodology moderated intervention effects. Twelve change techniques were associated with improvements in body image, and three techniques were contra-indicated. Conclusions The findings show that interventions engender only small improvements in body image, and underline the need for large-scale, high-quality trials in this area. The review identifies effective techniques that could be deployed in future interventions. PMID:26418470
Groesz, Lisa M; Levine, Michael P; Murnen, Sarah K
2002-01-01
The effect of experimental manipulations of the thin beauty ideal, as portrayed in the mass media, on female body image was evaluated using meta-analysis. Data from 25 studies (43 effect sizes) were used to examine the main effect of mass media images of the slender ideal, as well as the moderating effects of pre-existing body image problems, the age of the participants, the number of stimulus presentations, and the type of research design. Body image was significantly more negative after viewing thin media images than after viewing images of either average size models, plus size models, or inanimate objects. This effect was stronger for between-subjects designs, participants less than 19 years of age, and for participants who are vulnerable to activation of a thinness schema. Results support the sociocultural perspective that mass media promulgate a slender ideal that elicits body dissatisfaction. Implications for prevention and research on social comparison processes are considered. Copyright 2002 by John Wiley & Sons, Inc.
ERIC Educational Resources Information Center
Granberg, Ellen M.; Simons, Leslie Gordon; Simons, Ronald L.
2009-01-01
Social psychologists have amassed a large body of work demonstrating that overweight African American adolescent girls have generally positive self-images, particularly when compared with overweight females from other racial and ethnic groups. Some scholars have proposed that elements of African American social experience may contribute to the…
Appearance-related teasing, body dissatisfaction, and disordered eating: A meta-analysis.
Menzel, Jessie E; Schaefer, Lauren M; Burke, Natasha L; Mayhew, Laura L; Brannick, Michael T; Thompson, J Kevin
2010-09-01
A meta-analysis was conducted to determine the relationship between appearance and weight-based teasing and three outcome measures: body dissatisfaction, restrictive eating, and bulimic behaviors. Four meta-analyses were conducted. Fifty effect sizes (N=10,618) resulted in a moderate effect size of .39 for the relationship between weight teasing and body dissatisfaction; 24 effect sizes (N=7190) resulted in an effect size of .32 for the relationship between appearance teasing and body dissatisfaction; 20 effect sizes (N=4792) resulted in an effect size of .35 for the relationship between weight teasing and dietary restraint; and 22 effect sizes (N=5091) resulted in an effect size of .36 for the relationship between weight teasing and bulimic behaviors. Significant moderators that emerged were teasing measure type, publication type, study type, age group, and gender. The findings offer further support for the inclusion of strategies in body image and eating disorders' prevention and intervention programs that focus on handling negative, appearance-related commentary. Copyright © 2010 Elsevier Ltd. All rights reserved.
Phytoplankton off the Coast of Portugal
NASA Technical Reports Server (NTRS)
2002-01-01
A large phytoplankton bloom off of the coast of Portugal can be seen in this true-color image taken on April 23, 2002, by the Moderate-resolution Imaging Spectroradiometer (MODIS) aboard NASA's Terra satellite. The bloom is roughly half the size of Portugal and forms a bluish-green cloud in the water. The red spots in northwest Spain denote what are likely small agricultural fires. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC
Best Merge Region Growing Segmentation with Integrated Non-Adjacent Region Object Aggregation
NASA Technical Reports Server (NTRS)
Tilton, James C.; Tarabalka, Yuliya; Montesano, Paul M.; Gofman, Emanuel
2012-01-01
Best merge region growing normally produces segmentations with closed connected region objects. Recognizing that spectrally similar objects often appear in spatially separate locations, we present an approach for tightly integrating best merge region growing with non-adjacent region object aggregation, which we call Hierarchical Segmentation or HSeg. However, the original implementation of non-adjacent region object aggregation in HSeg required excessive computing time even for moderately sized images because of the required intercomparison of each region with all other regions. This problem was previously addressed by a recursive approximation of HSeg, called RHSeg. In this paper we introduce a refined implementation of non-adjacent region object aggregation in HSeg that reduces the computational requirements of HSeg without resorting to the recursive approximation. In this refinement, HSeg s region inter-comparisons among non-adjacent regions are limited to regions of a dynamically determined minimum size. We show that this refined version of HSeg can process moderately sized images in about the same amount of time as RHSeg incorporating the original HSeg. Nonetheless, RHSeg is still required for processing very large images due to its lower computer memory requirements and amenability to parallel processing. We then note a limitation of RHSeg with the original HSeg for high spatial resolution images, and show how incorporating the refined HSeg into RHSeg overcomes this limitation. The quality of the image segmentations produced by the refined HSeg is then compared with other available best merge segmentation approaches. Finally, we comment on the unique nature of the hierarchical segmentations produced by HSeg.
Hiwatashi, A; Togao, O; Yamashita, K; Kikuchi, K; Momosaka, D; Honda, H
2018-03-20
The purpose of this study was to correlate diffusivity of extraocular muscles, measured by three-dimensional turbo field echo (3DTFE) magnetic resonance (MR) imaging using diffusion-sensitized driven-equilibrium preparation, with their size and activity in patients with Grave's ophthalmopathy. Twenty-three patients with Grave's ophthalmopathy were included. There were 17 women and 6 men with a mean age of 55.8±12.6 (SD) years (range: 26-83 years). 3DTFE with diffusion-sensitized driven-equilibrium MR images were obtained with b-values of 0 and 500s/mm 2 . The apparent diffusion coefficient (ADC) of extraocular muscles was measured on coronal reformatted MR images. Signal intensities of extraocular muscles on conventional MR images were compared to those of normal-appearing white matter, and cross-sectional areas of the muscles were also measured. The clinical activity score was also evaluated. Statistical analyses were performed with Pearson correlation and Mann-Whitney U tests. On 3DTFE with diffusion-sensitized driven-equilibrium preparation, the mean ADC of the extraocular muscles was 2.23±0.37 (SD)×10 -3 mm2/s (range: 1.70×10 -3 -3.11×10 -3 mm 2 /s). There was a statistically significant moderate correlation between ADC and the size of the muscles (r=0.61). There were no statistically significant correlations between ADC and signal intensity on conventional MR and the clinical activity score. 3DTFE with diffusion-sensitized driven-equilibrium preparation technique allows quantifying diffusivity of extraocular muscles in patients with Grave's ophthalmopathy. The diffusivity of the extraocular muscles on 3DTFE with diffusion-sensitized driven-equilibrium preparation MR images moderately correlates with their size. Copyright © 2018. Published by Elsevier Masson SAS.
Autofocus algorithm for curvilinear SAR imaging
NASA Astrophysics Data System (ADS)
Bleszynski, E.; Bleszynski, M.; Jaroszewicz, T.
2012-05-01
We describe an approach to autofocusing for large apertures on curved SAR trajectories. It is a phase-gradient type method in which phase corrections compensating trajectory perturbations are estimated not directly from the image itself, but rather on the basis of partial" SAR data { functions of the slow and fast times { recon- structed (by an appropriate forward-projection procedure) from windowed scene patches, of sizes comparable to distances between distinct targets or localized features of the scene. The resulting partial data" can be shown to contain the same information on the phase perturbations as that in the original data, provided the frequencies of the perturbations do not exceed a quantity proportional to the patch size. The algorithm uses as input a sequence of conventional scene images based on moderate-size subapertures constituting the full aperture for which the phase corrections are to be determined. The subaperture images are formed with pixel sizes comparable to the range resolution which, for the optimal subaperture size, should be also approximately equal the cross-range resolution. The method does not restrict the size or shape of the synthetic aperture and can be incorporated in the data collection process in persistent sensing scenarios. The algorithm has been tested on the publicly available set of GOTCHA data, intentionally corrupted by random-walk-type trajectory uctuations (a possible model of errors caused by imprecise inertial navigation system readings) of maximum frequencies compatible with the selected patch size. It was able to eciently remove image corruption for apertures of sizes up to 360 degrees.
Remote sensing of the Fram Strait marginal ice zone
Shuchman, R.A.; Burns, B.A.; Johannessen, O.M.; Josberger, E.G.; Campbell, W.J.; Manley, T.O.; Lannelongue, N.
1987-01-01
Sequential remote sensing images of the Fram Strait marginal ice zone played a key role in elucidating the complex interactions of the atmosphere, ocean, and sea ice. Analysis of a subset of these images covering a 1-week period provided quantitative data on the mesoscale ice morphology, including ice edge positions, ice concentrations, floe size distribution, and ice kinematics. The analysis showed that, under light to moderate wind conditions, the morphology of the marginal ice zone reflects the underlying ocean circulation. High-resolution radar observations showed the location and size of ocean eddies near the ice edge. Ice kinematics from sequential radar images revealed an ocean eddy beneath the interior pack ice that was verified by in situ oceanographic measurements.
Droulers, Olivier; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used–for the first time in this context–to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers’ emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.). PMID:28910317
Droulers, Olivier; Gallopel-Morvan, Karine; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used-for the first time in this context-to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers' emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.).
Scale size-dependent characteristics of the nightside aurora
NASA Astrophysics Data System (ADS)
Humberset, B. K.; Gjerloev, J. W.; Samara, M.; Michell, R. G.
2017-02-01
We have determined the spatiotemporal characteristics of the magnetosphere-ionosphere (M-I) coupling using auroral imaging. Observations at fixed positions for an extended period of time are provided by a ground-based all-sky imager measuring the 557.7 nm auroral emissions. We report on a single event of nightside aurora (˜22 magnetic local time) preceding a substorm onset. To determine the spatiotemporal characteristics, we perform an innovative analysis of an all-sky imager movie (19 min duration, images at 3.31 Hz) that combines a two-dimensional spatial fast Fourier transform with a temporal correlation. We find a scale size-dependent variability where the largest scale sizes are stable on timescales of minutes while the small scale sizes are more variable. When comparing two smaller time intervals of different types of auroral displays, we find a variation in their characteristics. The characteristics averaged over the event are in remarkable agreement with the spatiotemporal characteristics of the nightside field-aligned currents during moderately disturbed times. Thus, two different electrodynamical parameters of the M-I coupling show similar behavior. This gives independent support to the claim of a system behavior that uses repeatable solutions to transfer energy and momentum from the magnetosphere to the ionosphere.
The impact of diagnostic imaging wait times on the prognosis of lung cancer.
Byrne, Suzanne C; Barrett, Brendan; Bhatia, Rick
2015-02-01
This study was performed to determine whether gaps in patient flow from initial lung imaging to computed tomography (CT) guided lung biopsy in patients with non-small cell lung cancer (NSCLC) was associated with a change in tumour size, stage, and thus prognosis. All patients who had a CT-guided lung biopsy in 2009 (phase I) and in 2011 (phase II) with a pathologic diagnosis of primary lung cancer (NSCLC) at Eastern Health, Newfoundland, were identified. Dates of initial abnormal imaging, confirmatory CT (if performed), and CT-guided biopsy were recorded, along with tumour size and resulting T stage at each time point. In 2010, wait times for diagnostic imaging at Eastern Health were reduced. The stage and prognosis of NSCLC in 2009 was compared with 2011. In phase 1, there was a statistically significant increase in tumour size (mean difference, 0.67 cm; P < .0001) and stage (P < .0001) from initial image to biopsy. There was a moderate correlation between the time (in days) between the images and change in size (r = 0.33, P = .008) or stage (r = 0.26, P = .036). In phase II, the median wait time from initial imaging to confirmatory CT was reduced to 7.5 days (from 19 days). At this reduced wait time, there was no statistically significant increase in tumour size (mean difference, 0.02; P > .05) or stage (P > .05) from initial imaging to confirmatory CT. Delays in patient flow through diagnostic imaging resulted in an increase in tumour size and stage, with a negative impact on prognosis of NSCLC. This information contributed to the hiring of additional CT technologists and extended CT hours to decrease the wait time for diagnostic imaging. With reduced wait times, the prognosis of NSCLC was not adversely impacted as patients navigated through diagnostic imaging. Copyright © 2015 Canadian Association of Radiologists. All rights reserved.
Tools to Improve the Accuracy of Kidney Stone Sizing with Ultrasound
Dunmire, Barbrina; Hsi, Ryan S.; Cunitz, Bryan W.; Paun, Marla; Bailey, Michael R.; Sorensen, Mathew D.; Harper, Jonathan D.
2015-01-01
Abstract Purpose: Ultrasound (US) overestimates stone size when compared with CT. The purpose of this work was to evaluate the overestimation of stone size with US in an in vitro water bath model and investigate methods to reduce overestimation. Materials and Methods: Ten human stones (3–12 mm) were measured using B-mode (brightness mode) US by a sonographer blinded to the true stone size. Images were captured and compared using both a commercial US machine and software-based research US device. Image gain was adjusted between moderate and high stone intensities, and the transducer-to-stone depth was varied from 6 to 10 cm. A computerized stone-sizing program was developed to outline the stone width based on a grayscale intensity threshold. Results: Overestimation with the commercial device increased with both gain and depth. Average overestimation at moderate and high gain was 1.9±0.8 and 2.1±0.9 mm, respectively (p=0.6). Overestimation increased an average of 22% with an every 2-cm increase in depth (p=0.02). Overestimation using the research device was 1.5±0.9 mm and did not vary with depth (p=0.28). Overestimation could be reduced to 0.02±1.1 mm (p<0.001) with the computerized stone-sizing program. However, a standardized threshold consistent across depth, system, or system settings could not be resolved. Conclusion: Stone size is consistently overestimated with US. Overestimation increased with increasing depth and gain using the commercial machine. Overestimation was reduced and did not vary with depth, using the software-based US device. The computerized stone-sizing program shows the potential to reduce overestimation by implementing a grayscale intensity threshold for defining the stone size. More work is needed to standardize the approach, but if successful, such an approach could significantly improve stone-sizing accuracy and lead to automation of stone sizing. PMID:25105243
Business aspects of cardiovascular computed tomography: tackling the challenges.
Bateman, Timothy M
2008-01-01
The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.
Kim, Mimi; Kang, Tae Wook; Kim, Young Kon; Kim, Seong Hyun; Kwon, Wooil; Ha, Sang Yun; Ji, Sang A
2016-03-01
To evaluate the correlation between grade of pancreatic neuroendocrine tumours (pNETs) based on the 2010 World Health Organization (WHO) classification and the apparent diffusion coefficient (ADC), and to assess whether the ADC value and WHO classification can predict recurrence-free survival (RFS) after surgery for pNETs. This retrospective study was approved by the Institutional Review Board. The requirement for informed consent was waived. Between March 2009 and November 2014, forty-nine patients who underwent magnetic resonance (MR) imaging with diffusion-weighted image and subsequent surgery for single pNETs were included. Correlations among qualitative MR imaging findings, quantitative ADC values, and WHO classifications were assessed. An ordered logistic regression test was used to control for tumour size as a confounding factor. The association between ADC value (or WHO classification) and RFS was analysed. All tumors (n=49) were classified as low- (n=29, grade 1), intermediate- (n=17, grade 2), and high-grade (n=3, grade 3), respectively. The mean ADC of pNETs was moderately negatively correlated with WHO classification before and after adjustment for tumour size (ρ=-0.64, p<0.001 and ρ=-0.55, p=0.001 respectively). RFS was significantly associated with WHO classification (p=0.007), but not with the ADC value (p=0.569). The ADC value of pNETs is moderately correlated with WHO tumour grade, regardless of tumour size. However, the WHO tumour classification of pNET may be more suitable for predicting RFS than the ADC value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
2002-01-01
This true-color image was taken over northern Australia on October 2, 2000, by the Moderate-resolution Imaging Spectroradiometer (MODIS), flying aboard NASA's Terra spacecraft. There are roughly a dozen wildfires visible in the scene, which spans from Western Australia , across the Northern Territory, and into Queensland. In this image, clouds appear bright white and smoke plume appear darker and greyish. The pixels containing the wildfires are colored red (hot) and yellow (hotter). There are quite a few large burn scars from previous wildfires, which appear as black splotches across the landscape. The large bay along northern shore is the Gulf of Carpentaria (visible in the full size image), which is roughly 400 miles (about 640 km) wide. Image by Brian Montgomery and Robert Simmon; Data courtesy MODIS Science Team, NASA GSFC
Mechanochemical synthesis of fluorescent carbon dots from cellulose powders
NASA Astrophysics Data System (ADS)
Chae, Ari; Ram Choi, Bo; Choi, Yujin; Jo, Seongho; Kang, Eun Bi; Lee, Hyukjin; Park, Sung Young; In, Insik
2018-04-01
A novel mechanochemical method was firstly developed to synthesize carbon nanodots (CNDs) or carbon nano-onions (CNOs) through high-pressure homogenization of cellulose powders as naturally abundant resource depending on the treatment times. While CNDs (less than 5 nm in size) showed spherical and amorphous morphology, CNOs (10-50 nm in size) presented polyhedral shape, and onion-like outer lattice structure, graphene-like interlattice spacing of 0.36 nm. CNOs showed blue emissions, moderate dispersibility in aqueous media, and high cell viability, which enables efficient fluorescence imaging of cellular media.
Ground truth spectrometry and imagery of eruption clouds to maximize utility of satellite imagery
NASA Technical Reports Server (NTRS)
Rose, William I.
1993-01-01
Field experiments with thermal imaging infrared radiometers were performed and a laboratory system was designed for controlled study of simulated ash clouds. Using AVHRR (Advanced Very High Resolution Radiometer) thermal infrared bands 4 and 5, a radiative transfer method was developed to retrieve particle sizes, optical depth and particle mass involcanic clouds. A model was developed for measuring the same parameters using TIMS (Thermal Infrared Multispectral Scanner), MODIS (Moderate Resolution Imaging Spectrometer), and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer). Related publications are attached.
Forest biomass estimated from MODIS and FIA data in the Lake States: MN, WI and MI, USA
Daolan Zheng; Linda S. Heath; Mark J. Ducey
2007-01-01
This study linked the Moderate Resolution Imaging Spectrometer and USDA Forest Service, Forest Inventory and Analysis (FIA) data through empirical models established using high-resolution Landsat Enhanced Thematic Mapper Plus observations to estimate aboveground biomass (AGB) in three Lake States in the north-central USA. While means obtained from larger sample sizes...
Dittmar, Helga; Howard, Sarah
2004-12-01
Previous experimental research indicates that the use of average-size women models in advertising prevents the well-documented negative effect of thin models on women's body image, while such adverts are perceived as equally effective (Halliwell & Dittmar, 2004). The current study extends this work by: (a) seeking to replicate the finding of no difference in advertising effectiveness between average-size and thin models (b) examining level of ideal-body internalization as an individual, internal factor that moderates women's vulnerability to thin media models, in the context of (c) comparing women in professions that differ radically in their focus on, and promotion of, the sociocultural ideal of thinness for women--employees in fashion advertising (n = 75) and teachers in secondary schools (n = 75). Adverts showing thin, average-size and no models were perceived as equally effective. High internalizers in both groups of women felt worse about their body image after exposure to thin models compared to other images. Profession affected responses to average-size models. Teachers reported significantly less body-focused anxiety after seeing average-size models compared to no models, while there was no difference for fashion advertisers. This suggests that women in professional environments with less focus on appearance-related ideals can experience increased body-esteem when exposed to average-size models, whereas women in appearance-focused professions report no such relief.
A moderate method for preparation DMSA coated Fe3O4 nanoparticles
NASA Astrophysics Data System (ADS)
Song, L. N.; Gu, N.; Zhang, Y.
2017-01-01
A moderate way to prepare water soluble magnetic Fe3O4 nanoparticles has been developed. Firstly, oleic acid coated Fe3O4 is prepared by coprecipitation. Second, oleic acid were replaced by 2,3-dimercaptosuccinnic acid (DMSA) to prepare DMSA/Fe3O4 in the mixed solution of n-hexane and acetone. After dialysis and filtration the DMSA/Fe3O4 can be transferred into distilled water to form stable Fe3O4 nanoparticle solutions. The TEM images indicated that the particles had spherical shape and the nanoparticles were found to be 12 nm with a relatively narrow size distribution with the hydrodynamic size of 30 nm. And the result of VSM shows that DMSA/Fe3O4 nanoparticles have a saturation magnetization of 31 emu/g. The IR spectra indicated that the iron oxide was located by carboxyl matrix.
Blasczyk-Schiep, Sybilla; Sokoła, Kaja; Fila-Witecka, Karolina; Kazén, Miguel
2016-06-01
We investigated dysfunctional cognitions about eating and body image in relation to personality styles in a group of professional models. Dysfunctional cognitions in professional models (n = 43) and a control group (n = 43) were assessed with the 'Eating Disorder Cognition Questionnaire' (EDCQ), eating attitudes with the 'Eating Attitudes Test' (EAT), and personality with the 'Personality Styles and Disorders Inventory' (PSDI-S). Models had higher scores than controls on the EDCQ and EAT and on nine scales of the PSDI-S. Moderation analyses showed significant interactions between groups and personality styles in predicting EDCQ scales: The ambitious/narcissistic style was related to "negative body and self-esteem", the conscientious/compulsive style to "dietary restraint", and the spontaneous/borderline style to "loss of control in eating". The results indicate that not all models are susceptible to dysfunctional cognitions about eating and body image. Models are at a higher risk of developing negative automatic thoughts and dysfunctional assumptions relating to body size, shape and weight, especially if they have high scores on the above personality styles.
Agreement and reading time for differently-priced devices for the digital capture of X-ray films.
Salazar, Antonio José; Camacho, Juan Camilo; Aguirre, Diego Andrés
2012-03-01
We assessed the reliability of three digital capture devices: a film digitizer (which cost US $15,000), a flat-bed scanner (US $1800) and a digital camera (US $450). Reliability was measured as the agreement between six observers when reading images acquired from a single device and also in terms of the pair-device agreement. The images were 136 chest X-ray cases. The variables measured were the interstitial opacities distribution, interstitial patterns, nodule size and percentage pneumothorax size. The agreement between the six readers when reading images acquired from a single device was similar for the three devices. The pair-device agreements were moderate for all variables. There were significant differences in reading-time between devices: the mean reading-time for the film digitizer was 93 s, it was 59 s for the flat-bed scanner and 70 s for the digital camera. Despite the differences in their cost, there were no substantial differences in the performance of the three devices.
a Region-Based Multi-Scale Approach for Object-Based Image Analysis
NASA Astrophysics Data System (ADS)
Kavzoglu, T.; Yildiz Erdemir, M.; Tonbul, H.
2016-06-01
Within the last two decades, object-based image analysis (OBIA) considering objects (i.e. groups of pixels) instead of pixels has gained popularity and attracted increasing interest. The most important stage of the OBIA is image segmentation that groups spectrally similar adjacent pixels considering not only the spectral features but also spatial and textural features. Although there are several parameters (scale, shape, compactness and band weights) to be set by the analyst, scale parameter stands out the most important parameter in segmentation process. Estimating optimal scale parameter is crucially important to increase the classification accuracy that depends on image resolution, image object size and characteristics of the study area. In this study, two scale-selection strategies were implemented in the image segmentation process using pan-sharped Qickbird-2 image. The first strategy estimates optimal scale parameters for the eight sub-regions. For this purpose, the local variance/rate of change (LV-RoC) graphs produced by the ESP-2 tool were analysed to determine fine, moderate and coarse scales for each region. In the second strategy, the image was segmented using the three candidate scale values (fine, moderate, coarse) determined from the LV-RoC graph calculated for whole image. The nearest neighbour classifier was applied in all segmentation experiments and equal number of pixels was randomly selected to calculate accuracy metrics (overall accuracy and kappa coefficient). Comparison of region-based and image-based segmentation was carried out on the classified images and found that region-based multi-scale OBIA produced significantly more accurate results than image-based single-scale OBIA. The difference in classification accuracy reached to 10% in terms of overall accuracy.
Mars global digital dune database and initial science results
Hayward, R.K.; Mullins, K.F.; Fenton, L.K.; Hare, T.M.; Titus, T.N.; Bourke, M.C.; Colaprete, A.; Christensen, P.R.
2007-01-01
A new Mars Global Digital Dune Database (MGD3) constructed using Thermal Emission Imaging System (THEMIS) infrared (IR) images provides a comprehensive and quantitative view of the geographic distribution of moderate- to large-size dune fields (area >1 kM2) that will help researchers to understand global climatic and sedimentary processes that have shaped the surface of Mars. MGD3 extends from 65??N to 65??S latitude and includes ???550 dune fields, covering ???70,000 km2, with an estimated total volume of ???3,600 km3. This area, when combined with polar dune estimates, suggests moderate- to large-size dune field coverage on Mars may total ???800,000 km2, ???6 times less than the total areal estimate of ???5,000,000 km2 for terrestrial dunes. Where availability and quality of THEMIS visible (VIS) or Mars Orbiter Camera. narrow-angle (MOC NA) images allow, we classify dunes and include dune slipface measurements, which are derived from gross dune morphology and represent the prevailing wind direction at the last time of significant dune modification. For dunes located within craters, the azimuth from crater centroid to dune field centroid (referred to as dune centroid azimuth) is calculated and can provide an accurate method for tracking dune migration within smooth-floored craters. These indicators of wind direction are compared to output from a general circulation model (GCM). Dune centroid azimuth values generally correlate to regional wind patterns. Slipface orientations are less well correlated, suggesting that local topographic effects may play a larger role in dune orientation than regional winds. Copyright 2007 by the American Geophysical Union.
Breakfast food health and acute exercise: Effects on state body image.
Hayes, Jacqueline F; Giles, Grace E; Mahoney, Caroline R; Kanarek, Robin B
2018-05-10
Food intake and exercise have been shown to alter body satisfaction in a state-dependent manner. One-time consumption of food perceived as unhealthy can be detrimental to body satisfaction, whereas an acute bout of moderate-intensity aerobic exercise can be beneficial. The current study examined the effect of exercise on state body image and appearance-related self-esteem following consumption of isocaloric foods perceived as healthy or unhealthy in 36 female college students (18-30 years old) in the Northeastern United States. Using a randomized-controlled design, participants attended six study sessions with breakfast conditions (healthy, unhealthy, no food) and activity (exercise, quiet rest) as within-participants factors. Body image questionnaires were completed prior to breakfast condition, between breakfast and activity conditions, and following activity condition. Results showed that consumption of an unhealthy breakfast decreased appearance self-esteem and increased body size perception, whereas consumption of a healthy breakfast did not influence appearance self-esteem but increased body size perception. Exercise did not influence state body image attitudes or perceptions following meal consumption. Study findings suggest that morning meal type, but not aerobic exercise, influence body satisfaction in college-aged females. Copyright © 2018. Published by Elsevier Ltd.
Parks, Connie L; Monson, Keith L
2017-04-01
The recognizability of facial images extracted from publically available medical scans raises patient privacy concerns. This study examined how accurately facial images extracted from computed tomography (CT) scans are objectively matched with corresponding photographs of the scanned individuals. The test subjects were 128 adult Americans ranging in age from 18 to 60 years, representing both sexes and three self-identified population (ancestral descent) groups (African, European, and Hispanic). Using facial recognition software, the 2D images of the extracted facial models were compared for matches against five differently sized photo galleries. Depending on the scanning protocol and gallery size, in 6-61 % of the cases, a correct life photo match for a CT-derived facial image was the top ranked image in the generated candidate lists, even when blind searching in excess of 100,000 images. In 31-91 % of the cases, a correct match was located within the top 50 images. Few significant differences (p > 0.05) in match rates were observed between the sexes or across the three age cohorts. Highly significant differences (p < 0.01) were, however, observed across the three ancestral cohorts and between the two CT scanning protocols. Results suggest that the probability of a match between a facial image extracted from a medical scan and a photograph of the individual is moderately high. The facial image data inherent in commonly employed medical imaging modalities may need to consider a potentially identifiable form of "comparable" facial imagery and protected as such under patient privacy legislation.
Statistical characterization of speckle noise in coherent imaging systems
NASA Astrophysics Data System (ADS)
Yaroslavsky, Leonid; Shefler, A.
2003-05-01
Speckle noise imposes fundamental limitation on image quality in coherent radiation based imaging and optical metrology systems. Speckle noise phenomena are associated with properties of objects to diffusely scatter irradiation and with the fact that in recording the wave field, a number of signal distortions inevitably occur due to technical limitations inherent to hologram sensors. The statistical theory of speckle noise was developed with regard to only limited resolving power of coherent imaging devices. It is valid only asymptotically as much as the central limit theorem of the probability theory can be applied. In applications this assumption is not always applicable. Moreover, in treating speckle noise problem one should also consider other sources of the hologram deterioration. In the paper, statistical properties of speckle due to the limitation of hologram size, dynamic range and hologram signal quantization are studied by Monte-Carlo simulation for holograms recorded in near and far diffraction zones. The simulation experiments have shown that, for limited resolving power of the imaging system, widely accepted opinion that speckle contrast is equal to one holds only for rather severe level of the hologram size limitation. For moderate limitations, speckle contrast changes gradually from zero for no limitation to one for limitation to less than about 20% of hologram size. The results obtained for the limitation of the hologram sensor"s dynamic range and hologram signal quantization reveal that speckle noise due to these hologram signal distortions is not multiplicative and is directly associated with the severity of the limitation and quantization. On the base of the simulation results, analytical models are suggested.
Park, Woochul; Epstein, Norman B
2013-04-01
This study examined the longitudinal relationship between self-esteem and body image distress, as well as the moderating effect of relationships with parents, among adolescents in Korea, using nationally representative prospective panel data. Regarding causal direction, the findings supported bi-directionality for girls, but for boys the association was unidirectional, in that their self-esteem predicted body image distress, but not vice versa. A gender difference also emerged in the moderating effect of quality of relationships with parents. For girls, relationships with parents moderated the effect of body image distress on self-esteem, such that when relationships with parents were better, the effect of greater body image distress on subsequent lower self-esteem was stronger than when relationships with parents were less positive. For boys, relationships with parents moderated the influence of self-esteem on body image distress, such that self-esteem reduced body image distress more when boys had better relationships with parents. Copyright © 2013. Published by Elsevier Ltd.
Influence of sampling window size and orientation on parafoveal cone packing density
Lombardo, Marco; Serrao, Sebastiano; Ducoli, Pietro; Lombardo, Giuseppe
2013-01-01
We assessed the agreement between sampling windows of different size and orientation on packing density estimates in images of the parafoveal cone mosaic acquired using a flood-illumination adaptive optics retinal camera. Horizontal and vertical oriented sampling windows of different size (320x160 µm, 160x80 µm and 80x40 µm) were selected in two retinal locations along the horizontal meridian in one eye of ten subjects. At each location, cone density tended to decline with decreasing sampling area. Although the differences in cone density estimates were not statistically significant, Bland-Altman plots showed that the agreement between cone density estimated within the different sampling window conditions was moderate. The percentage of the preferred packing arrangements of cones by Voronoi tiles was slightly affected by window size and orientation. The results illustrated the high importance of specifying the size and orientation of the sampling window used to derive cone metric estimates to facilitate comparison of different studies. PMID:24009995
Lautenschlaeger, Ines E; Hartmann, Antje; Sicken, Julia; Mohrs, Sabrina; Scholz, Volkher B; Neiger, Reto; Kramer, Martin
2013-01-01
Scintigraphy is currently the reference standard for diagnosing feline hyperthyroidism; however, computed tomography (CT) is more widely available in veterinary practice. The purposes of this prospective study were to describe the CT appearance of thyroid glands in cats with hyperthyroidism and compare CT findings with findings from (99m) Tc-pertechnetate scintigraphy. Twenty-five adult hyperthyroid cats were included. Plain CT images were acquired for each cat and the following characteristics recorded for each thyroid lobe: visibility, delineation, position, attenuation, shape, and subjective size. Scintigraphic images were also acquired and the following characteristics recorded: radiopharmaceutical uptake, delineation, ectopic foci, shape, and subjective size. In CT images, thyroid lobes were most commonly found between the second and fourth cervical vertebrae, dorsolateral to the trachea. Affected thyroid lobes (based on scintigraphy reference standard) were most commonly oval and moderately enlarged in CT images. A heterogeneous attenuation pattern (isoattenuating to adjacent soft tissues with hypo- and hyperattenuating foci) was most commonly found in affected thyroid lobes. A positive correlation (P < 0.01) was identified between CT and scintigraphy for left-to-right thyroid lobe size relationship and subjective size of the larger thyroid lobe. The CT estimated mass was significantly higher (median = 148.8; range = [0;357.6]) for the more active thyroid lobe compared to the less active thyroid lobe (median = 84.6; range = [0;312.3]); (W = 154; P < 0.01). Findings indicated that CT may not reliably differentiate unilateral vs. bilateral hyperthyroidism in cats; however, CT may be a reliable alternative test for correctly identifying the more active thyroid lobe. © 2013 Veterinary Radiology & Ultrasound.
Cai, Yu; McMurray, Matthew S.; Oguz, Ipek; Yuan, Hong; Styner, Martin A.; Lin, Weili; Johns, Josephine M.; An, Hongyu
2011-01-01
High resolution diffusion tensor imaging (DTI) can provide important information on brain development, yet it is challenging in live neonatal rats due to the small size of neonatal brain and motion-sensitive nature of DTI. Imaging in live neonatal rats has clear advantages over fixed brain scans, as longitudinal and functional studies would be feasible to understand neuro-developmental abnormalities. In this study, we developed imaging strategies that can be used to obtain high resolution 3D DTI images in live neonatal rats at postnatal day 5 (PND5) and PND14, using only 3 h of imaging acquisition time. An optimized 3D DTI pulse sequence and appropriate animal setup to minimize physiological motion artifacts are the keys to successful high resolution 3D DTI imaging. Thus, a 3D rapid acquisition relaxation enhancement DTI sequence with twin navigator echoes was implemented to accelerate imaging acquisition time and minimize motion artifacts. It has been suggested that neonatal mammals possess a unique ability to tolerate mild-to-moderate hypothermia and hypoxia without long term impact. Thus, we additionally utilized this ability to minimize motion artifacts in magnetic resonance images by carefully suppressing the respiratory rate to around 15/min for PND5 and 30/min for PND14 using mild-to-moderate hypothermia. These imaging strategies have been successfully implemented to study how the effect of cocaine exposure in dams might affect brain development in their rat pups. Image quality resulting from this in vivo DTI study was comparable to ex vivo scans. fractional anisotropy values were also similar between the live and fixed brain scans. The capability of acquiring high quality in vivo DTI imaging offers a valuable opportunity to study many neurological disorders in brain development in an authentic living environment. PMID:22013426
Tiggemann, Marika; Brown, Zoe; Zaccardo, Mia; Thomas, Nicole
2017-06-01
The present experiment aimed to investigate the impact of the addition of disclaimer labels to fashion magazine shoots on women's body dissatisfaction. Participants were 320 female undergraduate students who viewed fashion shoots containing a thin and attractive model with no disclaimer label, or a small, large, or very large disclaimer label, or product images. Although thin-ideal fashion shoot images resulted in greater body dissatisfaction than product images, there was no significant effect of disclaimer label. Internalisation of the thin ideal was found to moderate the effect of disclaimer label, such that internalisation predicted increased body dissatisfaction in the no label and small label conditions, but not in the larger label conditions. Overall, the results showed no benefit for any size of disclaimer label in ameliorating the negative effect of viewing thin-ideal media images. It was concluded that more extensive research is required before the effective implementation of disclaimer labels. Copyright © 2017 Elsevier Ltd. All rights reserved.
Big capabilities in small packages: hyperspectral imaging from a compact platform
NASA Astrophysics Data System (ADS)
Beasley, Matthew; Goldberg, Hannah; Voorhees, Christopher; Illsley, Peter
2016-09-01
We present the Compact Holographic Aberration-corrected Platform (CHAP) instrument, designed and developed at Planetary Resources Development Corporation. By combining a dispersive element with the secondary of a telescope, we are able to produce a relatively long focal length with moderate dispersion at the focal plane. This design enables us to build a capable hyperspectral imaging instrument within the size constraints of the Cubesat form-factor. The advantages of our design revolves around its simplicity: there are only two optical elements, producing both a white light and diffracted image. With the use of a replicated grating, we can produce a long focal length hyperspectral imager at a price point far below other spaceflight instruments. The design is scalable for larger platforms and since it has no transmitting optics and only two reflective surfaces could be designed to function at any desired wavelength. Our system will be capable of spectral imaging across the 400 to 900 nm spectral range for use in small body surveys.
NASA Technical Reports Server (NTRS)
Keeton, Tiffany; Barrick, Bradley; Cooksey, Kirstin; Cowart, Kevin; Florence, Victoria; Herdy, Claire; Padgett-Vasquez, Steve; Luvall, Jeffrey; Molthan, Andrew
2012-01-01
Ground-based studies conducted in Iraq have revealed the presence of potential human pathogens in airborne dust. According to the Environmental Protection Agency (EPA), airborne particulate matter below 2.5micron (PM2.5) can cause long-term damage to the human respiratory system. NASA fs Earth Observing System (EOS) can be used to determine spectral characteristics of dust particles and dust particle sizes. Comparing dust particle size from the Sahara and Arabian Deserts gives insight into the composition and atmospheric transport characteristics of dust from each desert. With the use of NASA SeaWiFS DeepBlue Aerosol, dust particle sizes were estimated using Angstrom Exponent. Brightness Temperature Difference (BTD) equation was used to determine the area of the dust storm. The Moderate-resolution Imaging Spectroradiometer (MODIS) on Terra satellite was utilized in calculating BTD. Mineral composition of a dust storm that occurred 17 April 2008 near Baghdad was determined using imaging spectrometer data from the JPL Spectral Library and EO-1 Hyperion data. Mineralogy of this dust storm was subsequently compared to that of a dust storm that occurred over the Bodele Depression in the Sahara Desert on 7 June 2003.
Brewer, Paul; Berryman, Fiona; Baker, De; Pynsent, Paul; Gardner, Adrian
2013-11-01
Retrospective sequential patient series. To establish the relationship between the magnitude of the deformity in scoliosis and patients' perception of their condition, as measured with Scoliosis Research Society-22 scores. A total of 93 untreated patients with adolescent idiopathic scoliosis were included retrospectively. The Cobb angle was measured from a plain radiograph, and volumetric asymmetry was measured by ISIS2 surface topography. The association between Scoliosis Research Society scores for function, pain, self-image, and mental health against Cobb angle and volumetric asymmetry was investigated using the Pearson correlation coefficient. Correlation of both Cobb angle and volumetric asymmetry with function and pain was weak (all < .23); these correlation values were not statistically significant. Correlation of Cobb angle and volumetric asymmetry with self-image, was higher, although still moderate (-.37 for Cobb angle and -.44 for volumetric asymmetry). Both were statistically significant (Cobb angle, p = .0002; volumetric asymmetry; p = .00001). Cobb angle contributed 13.8% to the linear relationship with self-image, whereas volumetric asymmetry contributed 19.3%. For mental health, correlation was statistically significant with Cobb angle (p = .011) and volumetric asymmetry (p = .0005), but the correlation was low to moderate (-.26 and -.35, respectively). Cobb angle contributed 6.9% to the linear relationship with mental health, whereas volumetric asymmetry contributed 12.4%. Volumetric asymmetry correlates better with both mental health and self-image compared with Cobb angle, but the correlation was only moderate. This study suggests that a patient's own perception of self-image and mental health is multifactorial and not completely explained through present objective measurements of the size of the deformity. This helps to explain the difficulties in any objective analysis of a problem with multifactorial perception issues. Further study is required to investigate other physical aspects of the deformity that may have a role in how patients view themselves. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Grating-Based Phase-Contrast Imaging of Tumor Angiogenesis in Lung Metastases
Li, Xiangting; Wang, Yujie; Ding, Bei; Shi, Chen; Liu, Huanhuan; Tang, Rongbiao; Sun, Jianqi; Yan, Fuhua; Zhang, Huan
2015-01-01
Purpose To assess the feasibility of the grating-based phase-contrast imaging (GPI) technique for studying tumor angiogenesis in nude BALB/c mice, without contrast agents. Methods We established lung metastatic models of human gastric cancer by injecting the moderately differentiated SGC-7901 gastric cancer cell line into the tail vein of nude mice. Samples were embedded in a 10% formalin suspension and dried before imaging. Grating-based X-ray phase-contrast images were obtained at the BL13W beamline of the Shanghai Synchrotron Radiation Facility (SSRF) and compared with histological sections. Results Without contrast agents, grating-based X-ray phase-contrast imaging still differentiated angiogenesis within metastatic tumors with high spatial resolution. Vessels, down to tens of microns, showed gray values that were distinctive from those of the surrounding tumors, which made them easily identifiable. The vessels depicted in the imaging study were similar to those identified on histopathology, both in size and shape. Conclusions Our preliminary study demonstrates that grating-based X-ray phase-contrast imaging has the potential to depict angiogenesis in lung metastases. PMID:25811626
Quantitative imaging biomarkers: Effect of sample size and bias on confidence interval coverage.
Obuchowski, Nancy A; Bullen, Jennifer
2017-01-01
Introduction Quantitative imaging biomarkers (QIBs) are being increasingly used in medical practice and clinical trials. An essential first step in the adoption of a quantitative imaging biomarker is the characterization of its technical performance, i.e. precision and bias, through one or more performance studies. Then, given the technical performance, a confidence interval for a new patient's true biomarker value can be constructed. Estimating bias and precision can be problematic because rarely are both estimated in the same study, precision studies are usually quite small, and bias cannot be measured when there is no reference standard. Methods A Monte Carlo simulation study was conducted to assess factors affecting nominal coverage of confidence intervals for a new patient's quantitative imaging biomarker measurement and for change in the quantitative imaging biomarker over time. Factors considered include sample size for estimating bias and precision, effect of fixed and non-proportional bias, clustered data, and absence of a reference standard. Results Technical performance studies of a quantitative imaging biomarker should include at least 35 test-retest subjects to estimate precision and 65 cases to estimate bias. Confidence intervals for a new patient's quantitative imaging biomarker measurement constructed under the no-bias assumption provide nominal coverage as long as the fixed bias is <12%. For confidence intervals of the true change over time, linearity must hold and the slope of the regression of the measurements vs. true values should be between 0.95 and 1.05. The regression slope can be assessed adequately as long as fixed multiples of the measurand can be generated. Even small non-proportional bias greatly reduces confidence interval coverage. Multiple lesions in the same subject can be treated as independent when estimating precision. Conclusion Technical performance studies of quantitative imaging biomarkers require moderate sample sizes in order to provide robust estimates of bias and precision for constructing confidence intervals for new patients. Assumptions of linearity and non-proportional bias should be assessed thoroughly.
Reproducibility of airway luminal size in asthma measured by HRCT.
Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A
2017-10-01
Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack of studies examining the reproducibility of high-resolution CT in asthma. The current study examined reproducibility of airway measurements. In stable well-controlled asthmatic subjects, it is possible to reproducibly image airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. Copyright © 2017 the American Physiological Society.
Bardone-Cone, Anna M; Cass, Kamila M
2007-09-01
This study experimentally examined the effects of viewing a pro-anorexia website. Following construction of a prototypic pro-anorexia website, 235 female undergraduates were randomly assigned to view either the pro-anorexia website or one of two comparison websites related to female fashion (using average-sized models) or home décor. Post-website affect, cognitions, and behavioral expectations were examined along with moderator effects. Study participants exposed to the pro-anorexia website had greater negative affect, lower social self-esteem, and lower appearance self-efficacy post-website than those who viewed a comparison website. Additionally, they perceived themselves as heavier, reported a greater likelihood of exercising and thinking about their weight in the near future, and engaged in more image comparison. Minimal support was found for moderator effects. Results provide an empirical basis for concern (expressed by clinicians, researchers, the media) that pro-anorexia websites are a troubling new form of thin-ideal exposure that warrants further examination. (c) 2007 by Wiley Periodicals, Inc.
Multispectral Snapshot Imagers Onboard Small Satellite Formations for Multi-Angular Remote Sensing
NASA Technical Reports Server (NTRS)
Nag, Sreeja; Hewagama, Tilak; Georgiev, Georgi; Pasquale, Bert; Aslam, Shahid; Gatebe, Charles K.
2017-01-01
Multispectral snapshot imagers are capable of producing 2D spatial images with a single exposure at selected, numerous wavelengths using the same camera, therefore operate differently from push broom or whiskbroom imagers. They are payloads of choice in multi-angular, multi-spectral imaging missions that use small satellites flying in controlled formation, to retrieve Earth science measurements dependent on the targets Bidirectional Reflectance-Distribution Function (BRDF). Narrow fields of view are needed to capture images with moderate spatial resolution. This paper quantifies the dependencies of the imagers optical system, spectral elements and camera on the requirements of the formation mission and their impact on performance metrics such as spectral range, swath and signal to noise ratio (SNR). All variables and metrics have been generated from a comprehensive, payload design tool. The baseline optical parameters selected (diameter 7 cm, focal length 10.5 cm, pixel size 20 micron, field of view 1.15 deg) and snapshot imaging technologies are available. The spectral components shortlisted were waveguide spectrometers, acousto-optic tunable filters (AOTF), electronically actuated Fabry-Perot interferometers, and integral field spectrographs. Qualitative evaluation favored AOTFs because of their low weight, small size, and flight heritage. Quantitative analysis showed that waveguide spectrometers perform better in terms of achievable swath (10-90 km) and SNR (greater than 20) for 86 wavebands, but the data volume generated will need very high bandwidth communication to downlink. AOTFs meet the external data volume caps well as the minimum spectral (wavebands) and radiometric (SNR) requirements, therefore are found to be currently feasible in spite of lower swath and SNR.
Application of Remote Sensing in Building Damages Assessment after Moderate and Strong Earthquake
NASA Astrophysics Data System (ADS)
Tian, Y.; Zhang, J.; Dou, A.
2003-04-01
- Earthquake is a main natural disaster in modern society. However, we still cannot predict the time and place of its occurrence accurately. Then it is of much importance to survey the damages information when an earthquake occurs, which can help us to mitigate losses and implement fast damage evaluation. In this paper, we use remote sensing techniques for our purposes. Remotely sensed satellite images often view a large scale of land at a time. There are several kinds of satellite images, which of different spatial and spectral resolutions. Landsat-4/5 TM sensor can view ground at 30m resolution, while Landsat-7 ETM Plus has a resolution of 15m in panchromatic waveband. SPOT satellite can provide images with higher resolutions. Those images obtained pre- and post-earthquake can help us greatly in identifying damages of moderate and large-size buildings. In this paper, we bring forward a method to implement quick damages assessment by analyzing both pre- and post-earthquake satellite images. First, those images are geographically registered together with low RMS (Root Mean Square) error. Then, we clip out residential areas by overlaying images with existing vector layers through Geographic Information System (GIS) software. We present a new change detection algorithm to quantitatively identify damages degree. An empirical or semi-empirical model is then established by analyzing the real damage degree and changes of pixel values of the same ground objects. Experimental result shows that there is a good linear relationship between changes of pixel values and ground damages, which proves the potentials of remote sensing in post-quake fast damage assessment. Keywords: Damages Assessment, Earthquake Hazard, Remote Sensing
Niebler, Gwendolyn; Dayno, Jeffrey
2016-01-01
Opioids are frequently used for treatment of moderate to severe short-term pain, but concerns exist about this treatment approach. Ketorolac tromethamine nasal spray, a nonsteroidal anti-inflammatory, is indicated for the short-term management of moderate to moderately severe pain requiring analgesia at the opioid level. However, there are no direct comparison studies between ketorolac nasal spray and opioids. The objective of this study was to use an effect size analysis to compare the effectiveness of ketorolac nasal spray with oral combination opioid formulations in treating moderate to severe short-term pain. An effect size analysis of three randomized, double-blind, placebo-controlled studies of third molar extraction surgery compared pain relief with ketorolac nasal spray and commonly prescribed combination opioids including hydrocodone/acetaminophen (APAP), oxycodone/APAP, oxycodone/ibuprofen and tramadol HCl/APAP. Effect size comparisons were made using total pain relief scores (TOTPAR6 or TOTPAR8; the weighted sum of pain relief scores through 6 or 8 h). Pain relief was measured using a five-point categorical rating scale (0 = none; 4 = complete). The effect size equivalent correlation, r, was determined using an online effect size calculator. The treatment effect size r compared with placebo was classified using established criteria (small = 0.20-0.49, moderate = 0.50-0.79 and large = ≥ 0.80). TOTPAR6 data indicated a moderate effect size for ketorolac nasal spray 31.5 mg (0.51) and oxycodone/ibuprofen 5/400 mg (0.64) and a small effect size for hydrocodone/APAP 7.5/500 mg (0.24) and oxycodone/APAP 5/325 mg (0.32). TOTPAR8 data indicated small effect sizes for ketorolac nasal spray (0.48), hydrocodone/APAP 10/650 mg (0.43), tramadol HCl/APAP 75/650 mg (0.35) and tramadol HCl/APAP 37.5/325 mg (0.17). The treatment effect sizes of ketorolac nasal spray were similar to or higher than the opioid comparators after third molar surgery, a well-accepted pain model. These results support ketorolac nasal spray as an effective treatment for moderate to moderately severe short-term pain.
Cotofana, S; Wyman, B T; Benichou, O; Dreher, D; Nevitt, M; Gardiner, J; Wirth, W; Hitzl, W; Kwoh, C K; Eckstein, F; Frobell, R B
2013-09-01
Conflicting associations between imaging biomarkers and pain in knee osteoarthritis (OA) have been reported. A relation between pain and denuded areas of subchondral bone (dABs) has been suggested and this study explores this relationship further by relating the presence, phenotype, location and size of dABs to different measures of knee pain. 633 right knees from the Osteoarthritis Initiative (OAI) (250 men, age 61.7 ± 9.6 yrs, BMI 29.4 ± 4.7 kg/m(2)) were included. Manual segmentation of the femorotibial cartilage plates was performed on 3 T coronal fast low angle shot with water excitation (FLASHwe) images. dABs were defined as areas where the subchondral bone was uncovered by cartilage. The following measures of pain were used: weightbearing-, non-weightbearing-, moderate-to-severe-, infrequent- and frequent knee pain. Using pain measures from subjects without dABs as a reference, those with at least one dAB had a 1.64-fold higher prevalence ratio [PR, 95% confidence interval (CI) 1.24-2.18] to have frequent and 1.45-fold higher for moderate-to-severe knee pain (95% CI 1.13-1.85). Subjects with dABs in central subregions had a 1.53-fold increased prevalence of having weightbearing pain (95% CI 1.20-1.97), especially when the central subregion was moderately (>10%) denuded (PR 1.81, 95% CI 1.35-2.42). Individuals with cartilage-loss-type dABs had a slightly higher prevalence (PR 1.13, 95% CI 1.00-1.27) of having frequent knee pain compared to individuals with intra-chondral-osteophyte-type dABs. This study supports a positive relation between femorotibial dABs and knee pain, especially when the dABs are located centrally (i.e., in weightbearing regions) or when the respective central subregion is moderately denuded. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Lombardo, Marco; Serrao, Sebastiano; Lombardo, Giuseppe
2014-01-01
Purpose To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. Methods Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degree temporal and superior eccentricity from the preferred locus of fixation (PRL). The technical factors that have been analyzed included the sampling window size, the corrected retinal magnification factor (RMFcorr), the conversion from radial to linear distance from the PRL, the displacement between the PRL and foveal center and the manual checking of cone identification algorithm. Bland-Altman analysis was used to assess the agreement between cone density estimated within the different sampling window conditions. Results The cone density declined with decreasing sampling area and data between areas of different size showed low agreement. A high agreement was found between sampling areas of the same size when comparing density calculated with or without using individual RMFcorr. The agreement between cone density measured at radial and linear distances from the PRL and between data referred to the PRL or the foveal center was moderate. The percentage of Voronoi tiles with hexagonal packing arrangement was comparable between sampling areas of different size. The boundary effect, presence of any retinal vessels, and the manual selection of cones missed by the automated identification algorithm were identified as the factors influencing variation of cone packing arrangements in Voronoi diagrams. Conclusions The sampling window size is the main technical factor that influences variation of cone density. Clear identification of each cone in the image and the use of a large buffer zone are necessary to minimize factors influencing variation of Voronoi diagrams of the cone mosaic. PMID:25203681
Lombardo, Marco; Serrao, Sebastiano; Lombardo, Giuseppe
2014-01-01
To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degree temporal and superior eccentricity from the preferred locus of fixation (PRL). The technical factors that have been analyzed included the sampling window size, the corrected retinal magnification factor (RMFcorr), the conversion from radial to linear distance from the PRL, the displacement between the PRL and foveal center and the manual checking of cone identification algorithm. Bland-Altman analysis was used to assess the agreement between cone density estimated within the different sampling window conditions. The cone density declined with decreasing sampling area and data between areas of different size showed low agreement. A high agreement was found between sampling areas of the same size when comparing density calculated with or without using individual RMFcorr. The agreement between cone density measured at radial and linear distances from the PRL and between data referred to the PRL or the foveal center was moderate. The percentage of Voronoi tiles with hexagonal packing arrangement was comparable between sampling areas of different size. The boundary effect, presence of any retinal vessels, and the manual selection of cones missed by the automated identification algorithm were identified as the factors influencing variation of cone packing arrangements in Voronoi diagrams. The sampling window size is the main technical factor that influences variation of cone density. Clear identification of each cone in the image and the use of a large buffer zone are necessary to minimize factors influencing variation of Voronoi diagrams of the cone mosaic.
Childhood maltreatment moderates the effect of combat exposure on cingulum structural integrity
BANIHASHEMI, LAYLA; WALLACE, MEREDITH L.; SHEU, LEI K.; LEE, MICHAEL C.; GIANAROS, PETER J.; MACKENZIE, ROBERT P.; INSANA, SALVATORE P.; GERMAIN, ANNE; HERRINGA, RYAN J.
2017-01-01
Limbic white matter pathways link emotion, cognition, and behavior and are potentially malleable to the influences of traumatic events throughout development. However, the impact of interactions between childhood and later life trauma on limbic white matter pathways has yet to be examined. Here, we examined whether childhood maltreatment moderated the effect of combat exposure on diffusion tensor imaging measures within a sample of military veterans (N = 28). We examined five limbic tracts of interest: two components of the cingulum (cingulum, cingulate gyrus, and cingulum hippocampus [CGH]), the uncinate fasciculus, the fornix/stria terminalis, and the anterior limb of the internal capsule. Using effect sizes, clinically meaningful moderator effects were found only within the CGH. Greater combat exposure was associated with decreased CGH fractional anisotropy (overall structural integrity) and increased CGH radial diffusivity (perpendicular water diffusivity) among individuals with more severe childhood maltreatment. Our findings provide preliminary evidence of the moderating effect of childhood maltreatment on the relationship between combat exposure and CGH structural integrity. These differences in CGH structural integrity could have maladaptive implications for emotion and memory, as well as provide a potential mechanism by which childhood maltreatment induces vulnerability to later life trauma exposure. PMID:29162178
Pisitsungkagarn, Kullaya; Taephant, Nattasuda; Attasaranya, Ploychompoo
2014-01-01
Body image satisfaction significantly influences self-esteem in female adolescents. Increased reports of lowered satisfaction in this population have raised concerns regarding their compromised self-esteem. This research study, therefore, sought to identify a culturally significant moderator of the association between body image satisfaction and self-esteem in Thai female adolescents. Orientation toward self-compassion, found to be particularly high in Thailand, was examined. A total of 302 Thai female undergraduates from three large public and private universities in the Bangkok metropolitan area responded to a set of questionnaires, which measured demographic information, body image satisfaction, self-compassion, and self-esteem. Data were analyzed using correlation and multiple regression analyses. Self-compassion was tested as a moderator of the relationship between body image satisfaction and self-esteem. Although its effect was relatively small, self-compassion significantly moderated the positive relationship between body image satisfaction and self-esteem. The relationship became less stringent for those with high self-compassion. The cultivation of self-compassion was recommended in female adolescents. In addition to moderating the association between body image satisfaction and self-esteem, the benefits to health and well-being of generalizing this cultivation are discussed.
Using Methane Absorption to Probe Jupiter's Atmosphere
NASA Technical Reports Server (NTRS)
1997-01-01
Mosaics of a belt-zone boundary near Jupiter's equator in near-infrared light moderately absorbed by atmospheric methane (top panel), and strongly absorbed by atmospheric methane (bottom panel). The four images that make up each of these mosaics were taken within a few minutes of each other. Methane in Jupiter's atmosphere absorbs light at specific wavelengths called absorption bands. By detecting light close and far from these absorption bands, Galileo can probe to different depths in Jupiter's atmosphere. Sunlight near 732 nanometers (top panel) is moderately absorbed by methane. Some of the light reflected from clouds deep in Jupiter's troposphere is absorbed, enhancing the higher features. Sunlight at 886 nanometers (bottom panel) is strongly absorbed by methane. Most of the light reflected from the deeper clouds is absorbed, making these clouds invisible. Features in the diffuse cloud layer higher in Jupiter's atmosphere are greatly enhanced.
North is at the top. The mosaic covers latitudes -13 to +3 degrees and is centered at longitude 282 degrees West. The smallest resolved features are tens of kilometers in size. These images were taken on November 5th, 1996, at a range of 1.2 million kilometers by the Solid State Imaging system aboard NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoSmagula, Stephen F; Wallace, Meredith L; Anderson, Stewart J; Karp, Jordan F; Lenze, Eric J; Mulsant, Benoit H; Butters, Meryl A; Blumberger, Daniel M; Diniz, Breno S; Lotrich, Francis E; Dew, Mary Amanda; Reynolds, Charles F
2016-10-01
Personalizing treatment for late-life depression requires identifying and integrating information from multiple factors that influence treatment efficacy (moderators). We performed exploratory moderator analyses using data from a multi-site, randomized, placebo-controlled, double-blind trial of aripiprazole augmentation. Patients (n = 159) aged ≥60 years had major depressive disorder that failed to remit with venlafaxine monotherapy. We examined effect sizes of 39 potential moderators of aripiprazole (vs. placebo) augmentation efficacy using the outcome of percentage reduction in depressive symptom after 12 weeks. We then incorporated information from the individually relevant variables in combined moderators. A larger aripiprazole treatment effect was related to: white race, better physical function, better performance on Trail-Making, attention, immediate, and delayed memory tests, greater psychomotor agitation and suicidality symptoms, and a history of adequate antidepressant pharmacotherapy. A smaller aripiprazole treatment effect was observed in patients with: more pain and more work/activity impairment and libido symptoms. Combining information from race and Trail-Making test performance (base combined moderator (Mb*)) produced a larger effect size (Spearman effect size = 0.29 (95% confidence interval (CI): 0.15, 0.42)) than any individual moderator. Adding other individually relevant moderators in the full combined moderator (Mf*) further improved effect size (Spearman effect size = 0.39 (95% CI: 0.25, 0.52)) and identified a sub-group benefiting more from placebo plus continuation venlafaxine monotherapy than adjunctive aripiprazole. Combining moderators can help clinicians personalize depression treatment. We found the majority of our patients benefited from adjunctive aripiprazole, but a smaller subgroup that is identifiable using clinical measures appeared to benefit more from continuation venlafaxine plus placebo. Copyright © 2016 Elsevier Ltd. All rights reserved.
Smagula, Stephen F.; Wallace, Meredith L.; Anderson, Stewart J.; Karp, Jordan F.; Lenze, Eric J.; Mulsant, Benoit H.; Butters, Meryl A.; Blumberger, Daniel M.; Diniz, Breno S.; Lotrich, Francis; Dew, Mary Amanda; Reynolds, Charles F.
2016-01-01
Personalizing treatment for late-life depression requires identifying and integrating information from multiple factors that influence treatment efficacy (moderators). We performed exploratory moderator analyses using data from a multi-site, randomized, placebo-controlled, double-blind trial of aripiprazole augmentation. Patients (n=159) aged ≥60 years had major depressive disorder that failed to remit with venlafaxine monotherapy. We examined effect sizes of 39 potential moderators of aripiprazole (vs. placebo) augmentation efficacy using the outcome of percentage reduction in depressive symptom after 12 weeks. We then incorporated information from the individually relevant variables in combined moderators. A larger aripiprazole treatment effect was related to: white race, better physical function, better performance on Trail-Making, attention, immediate, and delayed memory tests, greater psychomotor agitation and suicidality symptoms, and a history of adequate antidepressant pharmacotherapy. A smaller aripiprazole treatment effect was observed in patients with: more pain and more work/activity impairment and libido symptoms. Combining information from race and Trail-Making test performance (base combined moderator (Mb*)) produced a larger effect size (Spearman effect size=0.29 (95% confidence interval (CI): 0.15, 0.42)) than any individual moderator. Adding other individually relevant moderators in the full combined moderator (Mf*) further improved effect size (Spearman effect size=0.39 (95% CI: 0.25, 0.52)) and identified a sub-group benefiting more from placebo plus continuation venlafaxine monotherapy than adjunctive aripiprazole. Combining moderators can help clinicians personalize depression treatment. We found the majority of our patients benefited from adjunctive aripiprazole, but a smaller subgroup that is identifiable using clinical measures appeared to benefit more from continuation venlafaxine plus placebo. PMID:27438687
Pellizzer, Mia L; Waller, Glenn; Wade, Tracey D
2018-04-01
Predictors of attrition and predictors and moderators of outcome were explored in a transdiagnostic sample of patients who received ten-session cognitive behavioral therapy (CBT-T) for nonunderweight eating disorders. Body image flexibility, a protective positive body image construct, was hypothesized to be a significant moderator. Data from two case series were combined to form a sample of 78 participants who received CBT-T. Baseline measures of body image, negative affect, personality, and motivation (readiness to change and self-efficacy) were included as potential predictors. Global eating disorder psychopathology at each assessment point (baseline, mid- and post-treatment, 1- and 3-month follow-up) was the outcome variable. Predictors of attrition were assessed using logistic regression, and multilevel modeling was applied for predictors and moderators of outcome. Body image flexibility emerged as the strongest predictor and moderator of global eating disorder psychopathology, followed by body image avoidance. Body checking, negative affect, personality beliefs, and self-efficacy were significant predictors of global eating disorder psychopathology. Higher body image flexibility predicted lower global eating disorder psychopathology at every assessment point. Further research is required to replicate findings and explore the benefit of focusing on positive body image in treatment. © 2018 Wiley Periodicals, Inc.
High resolution laser mass spectrometry bioimaging.
Murray, Kermit K; Seneviratne, Chinthaka A; Ghorai, Suman
2016-07-15
Mass spectrometry imaging (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. Copyright © 2016 Elsevier Inc. All rights reserved.
A self-trained classification technique for producing 30 m percent-water maps from Landsat data
Rover, Jennifer R.; Wylie, Bruce K.; Ji, Lei
2010-01-01
Small bodies of water can be mapped with moderate-resolution satellite data using methods where water is mapped as subpixel fractions using field measurements or high-resolution images as training datasets. A new method, developed from a regression-tree technique, uses a 30 m Landsat image for training the regression tree that, in turn, is applied to the same image to map subpixel water. The self-trained method was evaluated by comparing the percent-water map with three other maps generated from established percent-water mapping methods: (1) a regression-tree model trained with a 5 m SPOT 5 image, (2) a regression-tree model based on endmembers and (3) a linear unmixing classification technique. The results suggest that subpixel water fractions can be accurately estimated when high-resolution satellite data or intensively interpreted training datasets are not available, which increases our ability to map small water bodies or small changes in lake size at a regional scale.
Retrieval of Snow Properties for Ku- and Ka-band Dual-Frequency Radar
NASA Technical Reports Server (NTRS)
Liao, Liang; Meneghini, Robert; Tokay, Ali; Bliven, Larry F.
2016-01-01
The focus of this study is on the estimation of snow microphysical properties and the associated bulk parameters such as snow water content and water equivalent snowfall rate for Ku- and Ka-band dual-frequency radar. This is done by exploring a suitable scattering model and the proper particle size distribution (PSD) assumption that accurately represent, in the electromagnetic domain, the micro/macro-physical properties of snow. The scattering databases computed from simulated aggregates for small-to-moderate particle sizes are combined with a simple scattering model for large particle sizes to characterize snow scattering properties over the full range of particle sizes. With use of the single-scattering results, the snow retrieval lookup tables can be formed in a way that directly links the Ku- and Ka-band radar reflectivities to snow water content and equivalent snowfall rate without use of the derived PSD parameters. A sensitivity study of the retrieval results to the PSD and scattering models is performed to better understand the dual-wavelength retrieval uncertainties. To aid in the development of the Ku- and Ka-band dual-wavelength radar technique and to further evaluate its performance, self-consistency tests are conducted using measurements of the snow PSD and fall velocity acquired from the Snow Video Imager Particle Image Probe (SVIPIP) duringthe winter of 2014 at the NASA Wallops Flight Facility site in Wallops Island, Virginia.
Retrieval of Snow Properties for Ku- and Ka-Band Dual-Frequency Radar
NASA Technical Reports Server (NTRS)
Liao, Liang; Meneghini, Robert; Tokay, Ali; Bliven, Larry F.
2016-01-01
The focus of this study is on the estimation of snow microphysical properties and the associated bulk parameters such as snow water content and water equivalent snowfall rate for Ku- and Ka-band dual-frequency radar. This is done by exploring a suitable scattering model and the proper particle size distribution (PSD) assumption that accurately represent, in the electromagnetic domain, the micro-macrophysical properties of snow. The scattering databases computed from simulated aggregates for small-to-moderate particle sizes are combined with a simple scattering model for large particle sizes to characterize snow-scattering properties over the full range of particle sizes. With use of the single-scattering results, the snow retrieval lookup tables can be formed in a way that directly links the Ku- and Ka-band radar reflectivities to snow water content and equivalent snowfall rate without use of the derived PSD parameters. A sensitivity study of the retrieval results to the PSD and scattering models is performed to better understand the dual-wavelength retrieval uncertainties. To aid in the development of the Ku- and Ka-band dual-wavelength radar technique and to further evaluate its performance, self-consistency tests are conducted using measurements of the snow PSD and fall velocity acquired from the Snow Video Imager Particle Image Probe (SVIPIP) during the winter of 2014 at the NASA Wallops Flight Facility site in Wallops Island, Virginia.
Shear wave elastography for breast masses is highly reproducible.
Cosgrove, David O; Berg, Wendie A; Doré, Caroline J; Skyba, Danny M; Henry, Jean-Pierre; Gay, Joel; Cohen-Bacrie, Claude
2012-05-01
To evaluate intra- and interobserver reproducibility of shear wave elastography (SWE) for breast masses. For intraobserver reproducibility, each observer obtained three consecutive SWE images of 758 masses that were visible on ultrasound. 144 (19%) were malignant. Weighted kappa was used to assess the agreement of qualitative elastographic features; the reliability of quantitative measurements was assessed by intraclass correlation coefficients (ICC). For the interobserver reproducibility, a blinded observer reviewed images and agreement on features was determined. Mean age was 50 years; mean mass size was 13 mm. Qualitatively, SWE images were at least reasonably similar for 666/758 (87.9%). Intraclass correlation for SWE diameter, area and perimeter was almost perfect (ICC ≥ 0.94). Intraobserver reliability for maximum and mean elasticity was almost perfect (ICC = 0.84 and 0.87) and was substantial for the ratio of mass-to-fat elasticity (ICC = 0.77). Interobserver agreement was moderate for SWE homogeneity (κ = 0.57), substantial for qualitative colour assessment of maximum elasticity (κ = 0.66), fair for SWE shape (κ = 0.40), fair for B-mode mass margins (κ = 0.38), and moderate for B-mode mass shape (κ = 0.58), orientation (κ = 0.53) and BI-RADS assessment (κ = 0.59). SWE is highly reproducible for assessing elastographic features of breast masses within and across observers. SWE interpretation is at least as consistent as that of BI-RADS ultrasound B-mode features. • Shear wave ultrasound elastography can measure the stiffness of breast tissue • It provides a qualitatively and quantitatively interpretable colour-coded map of tissue stiffness • Intraobserver reproducibility of SWE is almost perfect while intraobserver reproducibility of SWE proved to be moderate to substantial • The most reproducible SWE features between observers were SWE image homogeneity and maximum elasticity.
Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections
NASA Astrophysics Data System (ADS)
Ziock, K. P.; Boehnen, C. B.; Ernst, J. M.; Fabris, L.; Hayward, J. P.; Karnowski, T. P.; Paquit, V. C.; Patlolla, D. R.; Trombino, D. G.
2016-01-01
Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. The complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.
Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections
Ziock, Klaus -Peter; Boehnen, Chris Bensing; Ernst, Joseph M.; ...
2015-09-05
Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combinedmore » gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.« less
Dodd, Lori E; Korn, Edward L; Freidlin, Boris; Gu, Wenjuan; Abrams, Jeffrey S; Bushnell, William D; Canetta, Renzo; Doroshow, James H; Gray, Robert J; Sridhara, Rajeshwari
2013-10-01
Measurement error in time-to-event end points complicates interpretation of treatment effects in clinical trials. Non-differential measurement error is unlikely to produce large bias [1]. When error depends on treatment arm, bias is of greater concern. Blinded-independent central review (BICR) of all images from a trial is commonly undertaken to mitigate differential measurement-error bias that may be present in hazard ratios (HRs) based on local evaluations. Similar BICR and local evaluation HRs may provide reassurance about the treatment effect, but BICR adds considerable time and expense to trials. We describe a BICR audit strategy [2] and apply it to five randomized controlled trials to evaluate its use and to provide practical guidelines. The strategy requires BICR on a subset of study subjects, rather than a complete-case BICR, and makes use of an auxiliary-variable estimator. When the effect size is relatively large, the method provides a substantial reduction in the size of the BICRs. In a trial with 722 participants and a HR of 0.48, an average audit of 28% of the data was needed and always confirmed the treatment effect as assessed by local evaluations. More moderate effect sizes and/or smaller trial sizes required larger proportions of audited images, ranging from 57% to 100% for HRs ranging from 0.55 to 0.77 and sample sizes between 209 and 737. The method is developed for a simple random sample of study subjects. In studies with low event rates, more efficient estimation may result from sampling individuals with events at a higher rate. The proposed strategy can greatly decrease the costs and time associated with BICR, by reducing the number of images undergoing review. The savings will depend on the underlying treatment effect and trial size, with larger treatment effects and larger trials requiring smaller proportions of audited data.
Iceberg from Pine Island Glacier, Antarctica
2014-01-14
The voyage of Iceberg B-31 continued in January, 2014 as the giant iceberg drifted over the frigid waters of Pine Island Bay and widened the gap between the newly-calved iceberg and the “mother” glacier. Between November 9 and 11, 20143 a giant crack in the Pine Island Glacier gave completely away, liberating Iceberg B-31 from the end of the glacial tongue. The new iceberg was estimated to be 35 km by 20 km (21 mi by 12 mi) in size – or roughly the size of Singapore. On January 5, 2014 the Moderate Resolution Imaging Spectroradiometer (MODIS) aboard NASA’s Terra satellite captured this true-color image of B-31 floating in the center of Pine Island Bay on an approach to the Amundsen Sea. Pine Island Glacier can be seen on the upper right coast of the bay, and is marked by parallel lines in the ice. According to measurements reported by the National U.S. Ice Center, on January 10, B-31 was maintaining its size, and was located at 74°24'S and 104°33'W. Credit: NASA/GSFC/Jeff Schmaltz/MODIS Land Rapid Response Team NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Sensing, Spectra and Scaling: What's in Store for Land Observations
NASA Technical Reports Server (NTRS)
Goetz, Alexander F. H.
2001-01-01
Bill Pecora's 1960's vision of the future, using spacecraft-based sensors for mapping the environment and exploring for resources, is being implemented today. New technology has produced better sensors in space such as the Landsat Thematic Mapper (TM) and SPOT, and creative researchers are continuing to find new applications. However, with existing sensors, and those intended for launch in this century, the potential for extracting information from the land surface is far from being exploited. The most recent technology development is imaging spectrometry, the acquisition of images in hundreds of contiguous spectral bands, such that for any pixel a complete reflectance spectrum can be acquired. Experience with Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has shown that, with proper attention paid to absolute calibration, it is possible to acquire apparent surface reflectance to 5% accuracy without any ground-based measurement. The data reduction incorporates in educated guess of the aerosol scattering, development of a precipitable water vapor map from the data and mapping of cirrus clouds in the 1.38 micrometer band. This is not possible with TM. The pixel size in images of the earth plays and important role in the type and quality of information that can be derived. Less understood is the coupling between spatial and spectral resolution in a sensor. Recent work has shown that in processing the data to derive the relative abundance of materials in a pixel, also known is unmixing, the pixel size is an important parameter. A variance in the relative abundance of materials among the pixels is necessary to be able to derive the endmembers or pure material constituent spectra. In most cases, the 1 km pixel size for the Earth Observing System Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is too large to meet the variance criterion. A pointable high spatial and spectral resolution imaging spectrometer in orbit will be necessary to make the major next step in our understanding of the solid earth surface and its changing face.
Schwitter, Juerg; Gold, Michael R; Al Fagih, Ahmed; Lee, Sung; Peterson, Michael; Ciuffo, Allen; Zhang, Yan; Kristiansen, Nina; Kanal, Emanuel; Sommer, Torsten
2016-05-01
Recently, magnetic resonance (MR)-conditional implantable cardioverter defibrillator (ICD) systems have become available. However, associated cardiac MR image (MRI) quality is unknown. The goal was to evaluate the image quality performance of various cardiac MR sequences in a multicenter trial of patients implanted with an MR-conditional ICD system. The Evera-MRI trial enrolled 275 patients in 42 centers worldwide. There were 263 patients implanted with an Evera-MRI single- or dual-chamber ICD and randomized to controls (n=88) and MRI (n=175), 156 of whom underwent a protocol-required MRI (9-12 weeks post implant). Steady-state-free-precession (SSFP) and fast-gradient-echo (FGE) sequences were acquired in short-axis and horizontal long-axis orientations. Qualitative and quantitative assessment of image quality was performed by using a 7-point scale (grades 1-3: good quality, grades 6-7: nondiagnostic) and measuring ICD- and lead-related artifact size. Good to moderate image quality (grades 1-5) was obtained in 53% and 74% of SSFP and FGE acquisitions, respectively, covering the left ventricle, and in 69% and 84%, respectively, covering the right ventricle. Odds for better image quality were greater for right ventricle versus left ventricle (odds ratio, 1.8; 95% confidence interval, 1.5-2.2; P<0.0001) and greater for FGE versus SSFP (odds ratio, 3.5; 95% confidence interval, 2.5-4.8; P<0.0001). Compared with SSFP, ICD-related artifacts on FGE were smaller (141±65 versus 75±57 mm, respectively; P<0.0001). Lead artifacts were much smaller than ICD artifacts (P<0.0001). FGE yields good to moderate quality in 74% of left ventricle and 84% of right ventricle acquisitions and performs better than SSFP in patients with an MRI-conditional ICD system. In these patients, cardiac MRI can offer diagnostic information in most cases. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02117414. © 2016 American Heart Association, Inc.
Modelling the Shallow Water Equations in Curvilinear Coordinates with Physical Application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wingenter, Suzanne
2005-01-12
The goal of this project is to provide the capability for simulating fluid flow on complicated geometries, such as in the Bahia de Todos Santos. The Bahia de Todos Santos is a bay situated in the northwest corner of Mexico, off the coast of Ensenada and south of San Diego, California, USA. Figure 1.1 shows the Bahia de Todos Santos. It is part of an image taken from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors on the Aqua and Terra satellites in late June and early July 2003 [8]. Roughly 200 square kilometers in size, the bay also contains twomore » islands off the peninsula of Punta Banda. Characteristics of flow in this bay are driven by the moon tide (M2) and wind forcing [9].« less
Robbins, Lorraine B; Ling, Jiying; Resnicow, Kenneth
2017-12-06
Understanding factors related to girls' body image discrepancy, which is the difference between self-perceived current or actual and ideal body size, is important for addressing body-related issues and preventing adverse sequelae. Two aims were to: 1) examine demographic differences in body image discrepancy; and 2) determine the association of body image discrepancy with weight status, percent body fat, physical activity, sedentary behavior, and cardiovascular (CV) fitness among young adolescent girls. The cross-sectional study included a secondary analysis of baseline data from a group randomized controlled trial including 1519 5th-8th grade girls in 24 U.S. schools. Girls completed physical activity and sedentary behavior surveys. To indicate perceived current/actual and ideal body image, girls selected from nine body figures the one that represented how they look now and another showing how they want to look. Girls wore accelerometers measuring physical activity. Height, weight, and percent body fat were assessed. The Progressive Aerobic CV Endurance Run was used to estimate CV fitness. Independent t-test, one- and two-way ANOVA, correlational analyses, and hierarchical linear regressions were performed. The majority (67.5%; n = 1023) chose a smaller ideal than current/actual figure. White girls had higher body image discrepancy than Black girls (p = .035). Body image discrepancy increased with increasing weight status (F 3,1506 = 171.32, p < .001). Moderate-to-vigorous physical activity (MVPA) and vigorous physical activity were negatively correlated with body image discrepancy (r = -.10, p < .001; r = -.14, p < .001, respectively), but correlations were not significant after adjusting for race and body mass index (BMI), respectively. Body image discrepancy was moderately correlated with CV fitness (r = -.55, p < .001). After adjusting for demographics, percent body fat, but not CV fitness or MVPA, influenced body image discrepancy. Girls with higher percent body fat had higher body image discrepancy (p < .001). This study provided important information to guide interventions for promoting a positive body image among girls. ClinicalTrials.gov Identifier NCT01503333 , registration date: January 4, 2012.
Untangling the Space-Time Ambiguity of Auroral Emissions
NASA Astrophysics Data System (ADS)
Gjerloev, J. W.; Humberset, B.; Michell, R. G.; Samara, M.; Mann, I. R.
2012-12-01
In this paper we address the spatiotemporal characteristics of the magnetosphere-ionosphere (M-I) system as observed by an all-sky imager (ASI). We utilize 557.7 nm images obtained by a ground based ASI located under the dark ionosphere (~22 MLT) at Poker Flat, Alaska. The 19 min movie was recorded at 3.31 Hz during continuous moderately intense auroral activity driven by a southward IMF Bz of about -5 nT. We analyze this movie using a simple, yet robust, 2D FFT technique that allows us to determine the scale size dependent variability. When plotting the correlation pattern as a function of scale size and time separation we find a pattern with distinct regions of high and low correlation. Larger scale sizes are found to have longer duration. We interpret this remarkable result as indicative of a M-I system that uses repeatable solutions to transfer energy and momentum from the magnetosphere to the ionosphere. Our findings support the characteristics of the field-aligned currents as determined from multi-point satellite observations (ST-5, Gjerloev et al., Annales Geophysicae, 2011). Two different electromagnetic parameters, auroral emissions and field-aligned currents, display similar characteristics supporting our conclusion that this is indicative of a fundamental behavior of the M-I system.
Associations of Maternal Light/Moderate Leisure-Time Walking and Yoga With Offspring Birth Size.
Badon, Sylvia E; Littman, Alyson J; Chan, K C Gary; Williams, Michelle A; Enquobahrie, Daniel A
2018-06-01
Although perinatal walking and yoga have been associated with decreased risks of pregnancy complications, associations with offspring birth size have been inconsistent. We investigated associations of prepregnancy and early pregnancy leisure-time light/moderate walking and yoga practice with birth size. Study participants (N = 3687) reported leisure-time physical activity duration (hours per week) in the year before pregnancy and early pregnancy. Birth size was abstracted from medical records. Regression was used to determine mean differences in birth weight, head circumference, and ponderal index. Interaction terms were used to assess effect modification by offspring sex. About one-third of women reported light/moderate leisure-time walking and about 10% reported yoga practice. Women in the highest tertile for prepregnancy (mean: 2.9 h/wk; range: 1.4-20 h/wk) or early pregnancy (mean: 5.9 h/wk; range: 3.1-24 h/wk) light/moderate walking had offspring with 0.9 and 1.5 kg/m 3 greater ponderal index (95% confidence interval, 0.3 to 1.4 and 0.7 to 2.4, respectively) compared with women who reported no light/moderate walking in the same time period. Light/moderate walking was not associated with birth weight or head circumference. Yoga practice was not associated with birth size. Associations were similar by offspring sex. Light/moderate leisure-time walking may be associated with greater offspring ponderal index.
Mars global digital dune database: MC-30
Hayward, R.K.; Fenton, L.K.; Titus, T.N.; Colaprete, A.; Christensen, P.R.
2012-01-01
The Mars Global Digital Dune Database (MGD3) provides data and describes the methodology used in creating the global database of moderate- to large-size dune fields on Mars. The database is being released in a series of U.S. Geological Survey Open-File Reports. The first report (Hayward and others, 2007) included dune fields from lat 65° N. to 65° S. (http://pubs.usgs.gov/of/2007/1158/). The second report (Hayward and others, 2010) included dune fields from lat 60° N. to 90° N. (http://pubs.usgs.gov/of/2010/1170/). This report encompasses ~75,000 km2 of mapped dune fields from lat 60° to 90° S. The dune fields included in this global database were initially located using Mars Odyssey Thermal Emission Imaging System (THEMIS) Infrared (IR) images. In the previous two reports, some dune fields may have been unintentionally excluded for two reasons: (1) incomplete THEMIS IR (daytime) coverage may have caused us to exclude some moderate- to large-size dune fields or (2) resolution of THEMIS IR coverage (100 m/pixel) certainly caused us to exclude smaller dune fields. In this report, mapping is more complete. The Arizona State University THEMIS daytime IR mosaic provided complete IR coverage, and it is unlikely that we missed any large dune fields in the South Pole (SP) region. In addition, the increased availability of higher resolution images resulted in the inclusion of more small (~1 km2) sand dune fields and sand patches. To maintain consistency with the previous releases, we have identified the sand features that would not have been included in earlier releases. While the moderate to large dune fields in MGD3 are likely to constitute the largest compilation of sediment on the planet, we acknowledge that our database excludes numerous small dune fields and some moderate to large dune fields as well. Please note that the absence of mapped dune fields does not mean that dune fields do not exist and is not intended to imply a lack of saltating sand in other areas. Where availability and quality of THEMIS visible (VIS), Mars Orbiter Camera (MOC) narrow angle, Mars Express High Resolution Stereo Camera, or Mars Reconnaissance Orbiter Context Camera and High Resolution Imaging Science Experiment images allowed, we classified dunes and included some dune slipface measurements, which were derived from gross dune morphology and represent the approximate prevailing wind direction at the last time of significant dune modification. It was beyond the scope of this report to look at the detail needed to discern subtle dune modification. It was also beyond the scope of this report to measure all slipfaces. We attempted to include enough slipface measurements to represent the general circulation (as implied by gross dune morphology) and to give a sense of the complex nature of aeolian activity on Mars. The absence of slipface measurements in a given direction should not be taken as evidence that winds in that direction did not occur. When a dune field was located within a crater, the azimuth from crater centroid to dune field centroid was calculated, as another possible indicator of wind direction. Output from a general circulation model is also included. In addition to polygons locating dune fields, the database includes ~700 of the THEMIS VIS and MOC images that were used to build the database.
Building large area CZT imaging detectors for a wide-field hard X-ray telescope—ProtoEXIST1
NASA Astrophysics Data System (ADS)
Hong, J.; Allen, B.; Grindlay, J.; Chammas, N.; Barthelemy, S.; Baker, R.; Gehrels, N.; Nelson, K. E.; Labov, S.; Collins, J.; Cook, W. R.; McLean, R.; Harrison, F.
2009-07-01
We have constructed a moderately large area (32cm), fine pixel (2.5 mm pixel, 5 mm thick) CZT imaging detector which constitutes the first section of a detector module (256cm) developed for a balloon-borne wide-field hard X-ray telescope, ProtoEXIST1. ProtoEXIST1 is a prototype for the High Energy Telescope (HET) in the Energetic X-ray imaging Survey Telescope (EXIST), a next generation space-borne multi-wavelength telescope. We have constructed a large (nearly gapless) detector plane through a modularization scheme by tiling of a large number of 2cm×2cm CZT crystals. Our innovative packaging method is ideal for many applications such as coded-aperture imaging, where a large, continuous detector plane is desirable for the optimal performance. Currently we have been able to achieve an energy resolution of 3.2 keV (FWHM) at 59.6 keV on average, which is exceptional considering the moderate pixel size and the number of detectors in simultaneous operation. We expect to complete two modules (512cm) within the next few months as more CZT becomes available. We plan to test the performance of these detectors in a near space environment in a series of high altitude balloon flights, the first of which is scheduled for Fall 2009. These detector modules are the first in a series of progressively more sophisticated detector units and packaging schemes planned for ProtoEXIST2 & 3, which will demonstrate the technology required for the advanced CZT imaging detectors (0.6 mm pixel, 4.5m area) required in EXIST/HET.
Hinton-Yates, Denise P; Cury, Ricardo C; Wald, Lawrence L; Wiggins, Graham C; Keil, Boris; Seethmaraju, Ravi; Gangadharamurthy, Dakshinamurthy; Ogilvy, Christopher S; Dai, Guangping; Houser, Stuart L; Stone, James R; Furie, Karen L
2007-10-01
The aim of this article is to evaluate 3.0 T magnetic resonance imaging for characterization of vessel morphology and plaque composition. Emphasis is placed on early and moderate stages of carotid atherosclerosis, where increases in signal-to-noise (SNR) and contrast-to-noise (CNR) ratios compared with 1.5 T are sought. Comparison of in vivo 3.0 T imaging to histopathology is performed for validation. Parallel acceleration methods applied with an 8-channel carotid array are investigated as well as higher field ex vivo imaging to explore even further gains. The overall endeavor is to improve prospective assessment of atherosclerosis stage and stability for reduction of atherothrombotic event risk. A total of 10 male and female subjects ranging in age from 22 to 72 years (5 healthy and 5 with cardiovascular disease) participated. Custom-built array coils were used with endogenous and exogenous multicontrast bright and black-blood protocols for 3.0 T carotid imaging. Comparisons were performed to 1.5 T, and ex vivo plaque was stained with hematoxylin and eosin for histology. Imaging (9.4 T) was also performed on intact specimens. The factor of 2 gain in signal-to-noise SNR is realized compared with 1.5 T along with improved wall-lumen and plaque component CNR. Post-contrast black-blood imaging within 5-10 minutes of gadolinium injection is optimal for detection of the necrotic lipid component. In a preliminary 18-month follow-up study, this method provided measurement of a 50% reduction in lipid content with minimal change in plaque size in a subject receiving aggressive statin therapy. Parallel imaging applied with signal averaging further improves 3.0 T black-blood vessel wall imaging. The use of 3.0 T for carotid plaque imaging has demonstrated increases in SNR and CNR compared with 1.5 T. Quantitative prospective studies of moderate and early plaques are feasible at 3.0 T. Continued improvements in coil arrays, 3-dimensional pulse sequences, and the use of novel molecular imaging agents implemented at high field will further improve magnetic resonance plaque characterization.
Uncooled emissive infrared imagers for CubeSats
NASA Astrophysics Data System (ADS)
Puschell, Jeffery J.; Masini, Paolo
2014-09-01
Raytheon's fourth generation uncooled microbolometer array technology with digital output, High Definition (HD) 1920 × 1200 format and 12 μm cell size enables uncooled thermal infrared (TIR) multispectral imagers with the sensitivity and spatial sampling needed for a variety of Earth observation missions in LEO, GEO and HEO. A powerful combination of small detector cell size, fast optics and high sensitivity achieved without cryogenic cooling leads to instruments that are much smaller than current TIR systems, while still offering the capability to meet challenging measurement requirements for Earth observation missions. To consider how this technology could be implemented for Earth observation missions, we extend our previous studies with visible wavelength CubeSat imagers for environmental observations from LEO and examine whether small thermal infrared imagers based on fourth generation uncooled technology could be made small enough to fit onboard a 3U CubeSat and still meet challenging requirements for legacy missions. We found that moderate spatial resolution (~200 m) high sensitivity cloud and surface temperature observations meeting legacy MODIS/VIIRS requirements could be collected successfully with CubeSat-sized imagers but that multiple imagers are needed to cover the full swath for these missions. Higher spatial resolution land imagers are more challenging to fit into the CubeSat form factor, but it may be possible to do so for systems that require roughly 100 m spatial resolution. Regardless of whether it can fit into a CubeSat or not, uncooled land imagers meeting candidate TIR requirements can be implemented with a much smaller instrument than previous imagers. Even though this technology appears to be very promising, more work is needed to qualify this newly available uncooled infrared technology for use in space. If these new devices prove to be as space worthy as the first generation arrays that Raytheon qualified and built into the THEMIS imager still operating successfully onboard Mars Odyssey 2001, new classes of low cost, uncooled TIR Earth instruments will be enabled that are suitable for use as primary and hosted payloads in LEO, GEO and HEO or in constellations of small satellites as small as CubeSats to support Earth science measurement objectives in weather forecasting, land imaging and climate variability and change.
Moderate and late preterm birth: effect on brain size and maturation at term-equivalent age.
Walsh, Jennifer M; Doyle, Lex W; Anderson, Peter J; Lee, Katherine J; Cheong, Jeanie L Y
2014-10-01
To compare the size of multiple brain structures, maturation in terms of both brain myelination and gyral development, and evidence of brain injury between moderate and late preterm (MLPT) and term-born infants at term-equivalent age. The study was approved by the human research ethics committees of the participating hospitals, and informed parental consent was obtained for all infants. One hundred ninety-nine MLPT and 50 term-born infants underwent 3-T magnetic resonance (MR) imaging brain examinations at 38-44 weeks of corrected gestational age. T1- and T2-weighted MR images were compared between groups for size of multiple cerebral structures, degree of myelination in the posterior limb of the internal capsule, gyral maturation, signal intensity abnormalities, and presence of cysts by a single assessor who was blinded to the gestational group and perinatal course of the infants. Group differences were compared by using linear regression for continuous variables and logistic regression for categorical variables, and interrater and intrarater reliability was assessed by using intraclass correlation coefficients. Compared with those in the term-born control group, measurements of brain biparietal diameter, corpus callosum, basal ganglia and thalami, and cerebellum were smaller in infants in the MLPT group (all P ≤ .01), while extracerebral space was larger (P < .0001). Myelination of the posterior limb of the internal capsule was less developed, and gyral maturation was delayed in the MLPT group (both P < .001). Signal intensity abnormalities and cysts were uncommon in both groups, with 13 (6.5%) MLPT infants and one (2%) term infant having abnormalities. Inter- and intrarater reliability was good for most measures, with intraclass correlation coefficients generally greater than 0.68. MLPT birth is associated with smaller brain size, less-developed myelination of the posterior limb of the internal capsule, and more immature gyral folding than those associated with full-term birth. These brain changes may form the basis of some of the long-term neurodevelopmental deficits observed in MLPT children. Online supplemental material is available for this article. © RSNA, 2014.
NASA Technical Reports Server (NTRS)
Chu, D. A.; Remer, L. A.; Kaufman, Y. J.; Schmid, B.; Redemann, J.; Knobelspiesse, K.; Chern, J.-D.; Livingston, J.; Russell, P. B.; Xiong, X.;
2005-01-01
The Aerosol Characterization Experiment-Asia (ACE-Asia) was conducted in March-May 2001 in the western North Pacific in order to characterize the complex mix of dust, smoke, urban/industrial pollution, and background marine aerosol that is observed in that region in springtime. The Moderate Resolution Imaging Spectroradiometer (MODIS) provides a large-scale regional view of the aerosol during the ACE-Asia time period. Focusing only on aerosol retrievals over ocean, MODIS data show latitudinal and longitudinal variation in the aerosol characteristics. Typically, aerosol optical depth (tau(sub a)) values at 0.55 micrometers are highest in the 30 deg. - 50 deg. latitude band associated with dust outbreaks. Monthly mean tau(sub a) in this band ranges approx. 0.40-70, although large differences between monthly mean and median values indicate the periodic nature of these dust outbreaks. The size parameters, fine mode fraction (eta), and effective radius (r(sub eff)) vary between monthly mean values of eta = 0.47 and r(sub eff)= 0.75 micrometers in the cleanest regions far offshore to approximately eta = 0.85 and r(sub eff) =.30 micrometers in near-shore regions dominated by biomass burning smoke. The collocated MODIS retrievals with airborne, ship-based, and ground-based radiometers measurements suggest that MODIS retrievals of spectral optical depth fall well within expected error (DELTA tau(sub a) = plus or minus 0.03 plus or minus 0.05 tau(sub a)) except in situations dominated by dust, in which cases MODIS overestimate both the aerosol loading and the aerosol spectral dependence. Such behavior is consistent with issues related to particle nonsphericity. Comparisons of MODIS-derived r(sub eff) with AERONET retrievals at the few occurrences of collocations show MODIS systematically underestimates particle size by 0.2 micrometers. Multiple-year analysis of MODIS aerosol size parameters suggests systematic differences between the year 2001 and the years 2000 and 2002, which are traced to instrumental electronic cross talk. Sensitivity studies show that such calibration errors are negligible in tau(sub a) retrievals but are more pronounced in size parameter retrievals, especially for dust and sea salt.
Design of airborne imaging spectrometer based on curved prism
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao
2011-11-01
A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.
Fang, Su-Ying; Chang, Hong-Tai; Shu, Bih-Ching
2015-12-01
The aims of the study were the following: (1) to understand the relationship between women's perceptions of empathy from their partners and their depressive symptoms and body image and (2) to examine the moderating effects of women's perceptions of empathy from their partners on the relationship between body image and depressive symptoms. A cross-sectional and correlational design was used, in which a convenience sample of 151 women who completed surgery and the necessary chemotherapy/radiotherapy were recruited from southern Taiwan. A structured questionnaire including the Other Dyadic Perspective-Taking Scale, the Body Image Scale, and the Center for Epidemiologic Studies Depression scale were administered. Hierarchical regression was used to examine the moderating effects of empathy from partners between the women's body image and their level of depressive symptoms. The results showed significant relationships between empathy from a partner and depressive symptoms (p < 0.001). However, there was no significant relationship between empathy from a partner and body image (p > 0.05). The moderating effect of empathy from a partner on the relationship between body image and depressive symptoms was also significant (p < 0.01). The more empathy women perceived from partners, the fewer depressive symptoms women reported. Empathy from a partner could moderate the impact of body image changes on depressive symptoms. Women's depressive symptoms, resulting from a change in body image after breast cancer surgery, might be minimized if they perceived greater empathy from their partners. Copyright © 2015 John Wiley & Sons, Ltd.
Pétré, Benoit; Scheen, André J; Ziegler, Olivier; Donneau, Anne-Françoise; Dardenne, Nadia; Husson, Eddy; Albert, Adelin; Guillaume, Michèle
2016-01-01
Background and objective Despite the strength and consistency of the relationship between body mass index (BMI) and quality of life (QoL), a reduction in BMI does not necessarily lead to an improvement in QoL. Between-subject variability indicates the presence of mediators and moderators in the BMI–QoL association. This study aimed to examine the roles of body image discrepancy (BID) and subjective norm (SN) as potential mediators and moderators. Subjects and methods In 2012, 3,016 volunteers (aged ≥18 years) participated in a community-based survey conducted in the French-speaking region of Belgium. Participation was enhanced using a large multimedia campaign (which was supported by a large network of recruiters) that employed the nonstigmatizing slogan, “Whatever your weight, your opinion will count”. Participants were invited to complete a web-based questionnaire on their weight-related experiences. Self-reported measures were used to calculate each participant’s BMI, BID, SN, and QoL (a French obesity-specific QoL questionnaire was used to calculate the participants’ physical dimension of QoL scores [PHY-QoL], psychosocial dimension of QoL scores [PSY/SOC-QoL], and their total scores). The covariates included gender, age, subjective economic status, level of education, household size, and perceived health. The mediation/moderation tests were based on Hayes’ method. Results Tests showed that the relationships between BMI and PHY-QoL, PSY/SOC-QoL, and TOT-QoL were partially mediated by BID in both males and females and by SN in females. Moreover, BID was a moderator of the relationship between BMI and PSY/SOC-QoL in males and females. SN was a moderator of the relationship between BMI and PSY/SOC-QoL in males and between BMI and total scores in males (when used without BID in the models). Conclusion BID and SN should be considered as important factors in obesity management strategies. The study shows that targeting BMI only is not sufficient to improve the QoL of overweight and obese subjects, and that other variables, including perceptual factors, should be considered. PMID:27853356
Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama
Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration of follow-up of 197 days. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Walker, D Catherine; White, Emily K; Srinivasan, Vamshek J
2018-04-16
Body checking (BC) and body image avoidance (BIA) have been proposed as etiological and maintaining mechanisms for eating disorder (ED) pathology. To date, no comprehensive review summarizes the relationships of BC and BIA with ED pathology, body image dissatisfaction, or mood/affect. Meta-analyses examined the relationships of BC and BIA with ED pathology, body image dissatisfaction, and mood/affect. Gender, publication status, and presence or absence of ED diagnoses were examined as potential moderators. Results showed strong relationships between BC and ED pathology (ρ = 0.588) and BC and body image dissatisfaction (ρ = 0.631) and a moderate relationship between BC and mood/affect (ρ = 0.385). Similarly, results showed strong relationships between BIA and ED pathology (ρ = 0.553) and BIA and body image dissatisfaction (ρ = 0.543) and a moderate relationship between BIA and mood/affect (ρ = 0.392). Overall, limited evidence supported publication bias; however, publication bias may exist in the relationship between BIA and body image dissatisfaction in the literature. Subgroup moderator analyses suggested that gender moderates the strength of the relationships between BC and ED pathology, body image dissatisfaction, and mood/affect and between BIA and body image dissatisfaction. Results are consistent with cognitive-behavioral models of ED pathology that suggest BC and BIA are behavioral expressions of overvaluation of weight and shape. Notably, more published research has investigated BC than BIA. Future studies, incorporating methods such as meta-analytic structural equation modeling, should examine these variables to further test cognitive-behavioral models of ED development and maintenance. © 2018 Wiley Periodicals, Inc.
Treatment Effect on Recidivism for Juveniles Who Have Sexually Offended: a Multilevel Meta-Analysis.
Ter Beek, Ellis; Spruit, Anouk; Kuiper, Chris H Z; van der Rijken, Rachel E A; Hendriks, Jan; Stams, Geert Jan J M
2018-04-01
The current study investigated the effect on recidivism of treatment aimed at juveniles who have sexually offended. It also assessed the potential moderating effect of type of recidivism, and several treatment, participant and study characteristics. In total, 14 published and unpublished primary studies, making use of a comparison group and reporting on official recidivism rates, were included in a multilevel meta-analysis. This resulted in the use of 77 effect sizes, and 1726 participants. A three-level meta-analytic model was used to calculate the combined effect sizes (Cohens d) and to perform moderator analyses. Study quality was assessed with the EPHPP Quality Assessment Tool for Quantitative Studies. A moderate effect size was found (d = 0.37), indicating that the treatment groups achieved an estimated relative reduction in recidivism of 20.5% as compared to comparison groups. However, after controlling for publication bias, a significant treatment effect was no longer found. Type of recidivism did not moderate the effect of treatment, indicating that treatment groups were equally effective for all types of recidivism. Also, no moderating effects of participant or treatment characteristics were found. Regarding study characteristics, a shorter follow up time showed a trend for larger effect sizes, and the effect size calculation based on proportions yielded larger effect sizes than calculation via mean frequency of offending. Implications for future research and clinical practice are discussed.
NASA Astrophysics Data System (ADS)
Tosca, M. G.; Diner, D. J.; Garay, M. J.; Kalashnikova, O.
2013-12-01
Anthropogenic fires in Southeast Asia and Central America emit smoke that affects cloud dynamics, meteorology, and climate. We measured the cloud response to direct and indirect forcing from biomass burning aerosols using aerosol retrievals from the Multi-angle Imaging SpectroRadiometer (MISR) and non-synchronous cloud retrievals from the MODerate resolution Imaging Spectroradiometer (MODIS) from collocated morning and afternoon overpasses. Level 2 data from thirty-one individual scenes acquired between 2006 and 2010 were used to quantify changes in cloud fraction, cloud droplet size, cloud optical depth and cloud top temperature from morning (10:30am local time) to afternoon (1:30pm local time) in the presence of varying aerosol burdens. We accounted for large-scale meteorological differences between scenes by normalizing observed changes to the mean difference per individual scene. Elevated AODs reduced cloud fraction and cloud droplet size and increased cloud optical depths in both Southeast Asia and Central America. In mostly cloudy regions, aerosols significantly reduced cloud fraction and cloud droplet sizes, but in clear skies, cloud fraction, cloud optical thickness and cloud droplet sizes increased. In clouds with vertical development, aerosols reduced cloud fraction via semi-direct effects but spurred cloud growth via indirect effects. These results imply a positive feedback loop between anthropogenic burning and cloudiness in both Central America and Southeast Asia, and are consistent with previous studies linking smoke aerosols to both cloud reduction and convective invigoration.
Boersma, Katelyn E; Jarry, Josée L
2013-03-01
Weight-based derogatory media consist of derogation of celebrities for failing to meet the thin ideal. This study examined the impact of weight-based derogatory media on women's body satisfaction, appearance self-esteem, fear of negative appearance evaluation, and negative affect. Female undergraduates (N=240) were exposed to either tabloid-style pictures and articles derogating average size celebrities for gaining weight, or to the same images accompanied by neutral information. Women in the derogation condition reported greater fear of negative appearance evaluation than did women in the neutral media condition. Contrary to predictions, women low in maladaptive body image investment reported lower body satisfaction and appearance self-esteem in the derogatory media condition than they did in the neutral condition, while women high in maladaptive investment did not differ across conditions. Highly invested women's unexpected reaction may be understood as a defence against a threat to a valued domain of the self. Copyright © 2012 Elsevier Ltd. All rights reserved.
High Resolution Laser Mass Spectrometry Bioimaging
Murray, Kermit K.; Seneviratne, Chinthaka A.; Ghorai, Suman
2016-01-01
MSI (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10 μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. PMID:26972785
Fast Segmentation From Blurred Data in 3D Fluorescence Microscopy.
Storath, Martin; Rickert, Dennis; Unser, Michael; Weinmann, Andreas
2017-10-01
We develop a fast algorithm for segmenting 3D images from linear measurements based on the Potts model (or piecewise constant Mumford-Shah model). To that end, we first derive suitable space discretizations of the 3D Potts model, which are capable of dealing with 3D images defined on non-cubic grids. Our discretization allows us to utilize a specific splitting approach, which results in decoupled subproblems of moderate size. The crucial point in the 3D setup is that the number of independent subproblems is so large that we can reasonably exploit the parallel processing capabilities of the graphics processing units (GPUs). Our GPU implementation is up to 18 times faster than the sequential CPU version. This allows to process even large volumes in acceptable runtimes. As a further contribution, we extend the algorithm in order to deal with non-negativity constraints. We demonstrate the efficiency of our method for combined image deconvolution and segmentation on simulated data and on real 3D wide field fluorescence microscopy data.
The impact of exposure to films of natural and built environments on state body appreciation.
Swami, Viren; Pickering, Mark; Barron, David; Patel, Shreepali
2018-06-12
Previous work has shown that exposure to images of nature results in elevated state body appreciation, but static images may lack ecological validity. Here, we examined the impact of exposure to short films of simulated, first-person walks in natural or built environments. Thirty-six university students completed a measure of state body appreciation before and after watching films of either a walk in a natural or a built environment created specifically for the present study. Two weeks later, they completed the same task but watched the other film type. Results indicated that exposure to the film of a natural environment resulted in significantly elevated state body appreciation (d = 0.66). There was no significant change in state body appreciation following exposure to the film of the built environment (d = 0.14). These findings suggest that exposure to films depicting the natural environment may promote immediate, moderate-sized improvements in state body image. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kopka, Michaela; Fourman, Mitchell; Soni, Ashish; Cordle, Andrew C; Lin, Albert
2017-09-01
The Walch classification is the most recognized means of assessing glenoid wear in preoperative planning for shoulder arthroplasty. This classification relies on advanced imaging, which is more expensive and less practical than plain radiographs. The purpose of this study was to determine whether the Walch classification could be accurately applied to x-ray images compared with magnetic resonance imaging (MRI) as the gold standard. We hypothesized that x-ray images cannot adequately replace advanced imaging in the evaluation of glenoid wear. Preoperative axillary x-ray images and MRI scans of 50 patients assessed for shoulder arthroplasty were independently reviewed by 5 raters. Glenoid wear was individually classified according to the Walch classification using each imaging modality. The raters then collectively reviewed the MRI scans and assigned a consensus classification to serve as the gold standard. The κ coefficient was used to determine interobserver agreement for x-ray images and independent MRI reads, as well as the agreement between x-ray images and consensus MRI. The inter-rater agreement for x-ray images and MRIs was "moderate" (κ = 0.42 and κ = 0.47, respectively) for the 5-category Walch classification (A1, A2, B1, B2, C) and "moderate" (κ = 0.54 and κ = 0.59, respectively) for the 3-category Walch classification (A, B, C). The agreement between x-ray images and consensus MRI was much lower: "fair-to-moderate" (κ = 0.21-0.51) for the 5-category and "moderate" (κ = 0.36-0.60) for the 3-category Walch classification. The inter-rater agreement between x-ray images and consensus MRI is "fair-to-moderate." This is lower than the previously reported reliability of the Walch classification using computed tomography scans. Accordingly, x-ray images are inferior to advanced imaging when assessing glenoid wear. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
2002-01-01
Full-size images June 17, 2001 (2.0 MB JPEG) June 14, 2000 (2.1 MB JPEG) Light snowfall in the winter of 2000-01 led to a dry summer in the Pacific Northwest. The drought led to a conflict between farmers and fishing communities in the Klamath River Basin over water rights, and a series of forest fires in Washington, Oregon, and Northern California. The pair of images above, both acquired by the Enhanced Thematic Mapper Plus (ETM+) aboard the Landsat 7 satellite, show the snowpack on Mt. Shasta in June 2000 and 2001. On June 14, 2000, the snow extends to the lower slopes of the 4,317-meter (14,162-foot) volcano. At nearly the same time this year (June 17, 2001) the snow had retreated well above the tree-line. The drought in the region was categorized as moderate to severe by the National Oceanographic and Atmospheric Administration (NOAA), and the United States Geological Survey (USGS) reported that streamflow during June was only about 25 percent of the average. Above and to the left of Mt. Shasta is Lake Shastina, a reservoir which is noticeably lower in the 2001 image than the 2000 image. Images courtesy USGS EROS Data Center and the Landsat 7 Science Team
NASA Technical Reports Server (NTRS)
Houlahan, Padraig; Scalo, John
1992-01-01
A new method of image analysis is described, in which images partitioned into 'clouds' are represented by simplified skeleton images, called structure trees, that preserve the spatial relations of the component clouds while disregarding information concerning their sizes and shapes. The method can be used to discriminate between images of projected hierarchical (multiply nested) and random three-dimensional simulated collections of clouds constructed on the basis of observed interstellar properties, and even intermediate systems formed by combining random and hierarchical simulations. For a given structure type, the method can distinguish between different subclasses of models with different parameters and reliably estimate their hierarchical parameters: average number of children per parent, scale reduction factor per level of hierarchy, density contrast, and number of resolved levels. An application to a column density image of the Taurus complex constructed from IRAS data is given. Moderately strong evidence for a hierarchical structural component is found, and parameters of the hierarchy, as well as the average volume filling factor and mass efficiency of fragmentation per level of hierarchy, are estimated. The existence of nested structure contradicts models in which large molecular clouds are supposed to fragment, in a single stage, into roughly stellar-mass cores.
Self-image of the Patients with Head and Neck Cancer: A Mixed Method Research.
Nayak, Shalini G; Pai, Mamatha Shivananda; George, Linu Sara
2016-01-01
The aim of the study was to assess the self-image of the patients with head and neck cancers (HNCs) by using a mixed method research. A mixed method approach and triangulation design was used with the aim of assessing the self-image of the patients with HNCs. Data was gathered by using self-administered self-image scale and structured interview. Nested sampling technique was adopted. Sample size for quantitative approach was 54 and data saturation was achieved with seven subjects for qualitative approach. Institutional Ethical Committee clearance was obtained. The results of the study showed that 30 (56%) subjects had positive self-image and 24 (44%) had negative self-image. There was a moderate positive correlation between body image and integrity (r = 0.430, P = 0.001), weak positive correlation between body image and self-esteem (r = 0.270, P = 0.049), and no correlation between self-esteem and integrity (r = 0.203, P = 0.141). The participants also scored maximum (24/24) in the areas of body image and self-esteem. Similar findings were also observed in the phenomenological approach. The themes evolved were immaterial of outer appearance and desire of good health to all. The illness is long-term and impacts the individual 24 h a day. Understanding patients' self-concept and living experiences of patients with HNC is important for the health care professionals to improve the care.
D. A. Roberts; P.E. Dennison; S. Peterson; S. Sweeney; J. Rechel
2006-01-01
Dynamic changes in live fuel moisture (LFM) and fuel condition modify fire danger in shrublands. We investigated the empirical relationship between field-measured LFM and remotely sensed greenness and moisture measures from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and the Moderate Resolution Imaging Spectrometer (MODIS). Key goals were to assess the...
Fuller, J Bryan; Marler, Laura; Hester, Kim; Frey, Len; Relyea, Clint
2006-12-01
According to Social Identity Theory (cf., J. G. March & H. A. Simon, 1958), individuals tend to identify with prestigious or high-status groups. Researchers (J. E. Dutton, J. M. Dukerich, & C. V. Harquail, 1994) have revealed that organizational members also identify with organizations that have attractive public images. To gain a better understanding of the theoretical reasons underlying the relationship between image and identification in organizations, the authors examined this relationship in a healthcare setting. In addition, they investigated need for esteem as a moderator of the relationship between construed external image and organizational identification. Consistent with previous findings, the present results indicated that construed external image is positively related to organizational identification. Perhaps it is more important that the present findings also supported need for esteem as a moderator of the relationship between construed external image and organizational identification.
Wang, Wei; Ding, Jianhui; Li, Yuan; Wang, Chaofu; Zhou, Liangping; Zhu, Hui; Peng, Weijun
2014-01-01
To characterize Xp11.2 translocation renal cell carcinoma (RCC) using magnetic resonance imaging (MRI) and computed tomography (CT). This study retrospectively collected the MRI and CT data of twelve patients with Xp11.2 translocation RCC confirmed by pathology. Nine cases underwent dynamic contrast-enhanced MRI (DCE-MRI) and 6 cases underwent CT, of which 3 cases underwent MRI and CT simultaneously. The MRI and CT findings were analyzed in regard to tumor position, size, hemorrhagic, cystic or necrotic components, calcification, tumor density, signal intensity and enhancement features. The age of the 12 patients ranged from 13 to 46 years (mean age: 23 years). T2WI revealed heterogeneous intensity, hyper-intensity, and slight hypo-intensity in 6 cases, 2 cases, and 1 case, respectively. On DCE-MR images, mild, moderate, and marked rim enhancement of the tumor in the corticomedullary phase (CMP) were observed in 1, 6, and 2 cases, respectively. The tumor parenchyma showed iso-attenuation (n = 4) or slight hyper-attenuation (n = 1) compared to the normal renal cortex on non-contrast CT images. Imaging findings were suggestive of hemorrhage (n = 4) or necrosis (n = 8) in the tumors, and there was evidence of calcification in 8 cases by CT (n = 3) and pathology (n = 8). On dynamic contrast-enhanced CT images, 3 cases and 1 case manifested moderate and strong CMP enhancement, respectively. Nine tumors by MRI and 4 tumors by CT showed prolonged enhancement. Three neoplasms presented at stage I, 2 at stage II, 3 at stage III, and 4 at stage IV according the 2010 AJCC staging criteria. XP11.2 translocation RCC should be considered when a child or young adult patient presents with a renal tumor with heterogeneous features such as hemorrhage, necrosis, cystic changes, and calcification on CT and MRI and/or is accompanied by metastatic evidence.
Li, Yuan; Wang, Chaofu; Zhou, Liangping; Zhu, Hui; Peng, Weijun
2014-01-01
Purpose To characterize Xp11.2 translocation renal cell carcinoma (RCC) using magnetic resonance imaging (MRI) and computed tomography (CT). Methods This study retrospectively collected the MRI and CT data of twelve patients with Xp11.2 translocation RCC confirmed by pathology. Nine cases underwent dynamic contrast-enhanced MRI (DCE-MRI) and 6 cases underwent CT, of which 3 cases underwent MRI and CT simultaneously. The MRI and CT findings were analyzed in regard to tumor position, size, hemorrhagic, cystic or necrotic components, calcification, tumor density, signal intensity and enhancement features. Results The age of the 12 patients ranged from 13 to 46 years (mean age: 23 years). T2WI revealed heterogeneous intensity, hyper-intensity, and slight hypo-intensity in 6 cases, 2 cases, and 1 case, respectively. On DCE-MR images, mild, moderate, and marked rim enhancement of the tumor in the corticomedullary phase (CMP) were observed in 1, 6, and 2 cases, respectively. The tumor parenchyma showed iso-attenuation (n = 4) or slight hyper-attenuation (n = 1) compared to the normal renal cortex on non-contrast CT images. Imaging findings were suggestive of hemorrhage (n = 4) or necrosis (n = 8) in the tumors, and there was evidence of calcification in 8 cases by CT (n = 3) and pathology (n = 8). On dynamic contrast-enhanced CT images, 3 cases and 1 case manifested moderate and strong CMP enhancement, respectively. Nine tumors by MRI and 4 tumors by CT showed prolonged enhancement. Three neoplasms presented at stage I, 2 at stage II, 3 at stage III, and 4 at stage IV according the 2010 AJCC staging criteria. Conclusions XP11.2 translocation RCC should be considered when a child or young adult patient presents with a renal tumor with heterogeneous features such as hemorrhage, necrosis, cystic changes, and calcification on CT and MRI and/or is accompanied by metastatic evidence. PMID:24926688
Entwistle, A
2004-06-01
A means for improving the contrast in the images produced from digital light micrographs is described that requires no intervention by the experimenter: zero-order, scaling, tonally independent, moderated histogram equalization. It is based upon histogram equalization, which often results in digital light micrographs that contain regions that appear to be saturated, negatively biased or very grainy. Here a non-decreasing monotonic function is introduced into the process, which moderates the changes in contrast that are generated. This method is highly effective for all three of the main types of contrast found in digital light micrography: bright objects viewed against a dark background, e.g. fluorescence and dark-ground or dark-field image data sets; bright and dark objects sets against a grey background, e.g. image data sets collected with phase or Nomarski differential interference contrast optics; and darker objects set against a light background, e.g. views of absorbing specimens. Moreover, it is demonstrated that there is a single fixed moderating function, whose actions are independent of the number of elements of image data, which works well with all types of digital light micrographs, including multimodal or multidimensional image data sets. The use of this fixed function is very robust as the appearance of the final image is not altered discernibly when it is applied repeatedly to an image data set. Consequently, moderated histogram equalization can be applied to digital light micrographs as a push-button solution, thereby eliminating biases that those undertaking the processing might have introduced during manual processing. Finally, moderated histogram equalization yields a mapping function and so, through the use of look-up tables, indexes or palettes, the information present in the original data file can be preserved while an image with the improved contrast is displayed on the monitor screen.
The effect of human image in B2C website design: an eye-tracking study
NASA Astrophysics Data System (ADS)
Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo
2014-09-01
On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.
Wu, Zhiwei; He, Hong S; Liang, Yu; Cai, Longyan; Lewis, Bernard J
2013-10-01
Fire is a dominant process in boreal forest landscapes and creates a spatial patch mosaic with different burn severities and age classes. Quantifying effects of vegetation and topography on burn severity provides a scientific basis on which forest fire management plans are developed to reduce catastrophic fires. However, the relative contribution of vegetation and topography to burn severity is highly debated especially under extreme weather conditions. In this study, we hypothesized that relationships of vegetation and topography to burn severity vary with fire size. We examined this hypothesis in a boreal forest landscape of northeastern China by computing the burn severity of 24 fire patches as the difference between the pre- and post-fire Normalized Difference Vegetation Index obtained from two Landsat TM images. The vegetation and topography to burn severity relationships were evaluated at three fire-size levels of small (<100 ha, n = 12), moderate (100-1,000 ha, n = 9), and large (>1,000 ha, n = 3). Our results showed that vegetation and topography to burn severity relationships were fire-size-dependent. The burn severity of small fires was primary controlled by vegetation conditions (e.g., understory cover), and the burn severity of large fires was strongly influenced by topographic conditions (e.g., elevation). For moderate fires, the relationships were complex and indistinguishable. Our results also indicated that the pattern trends of relative importance for both vegetation and topography factors were not dependent on fire size. Our study can help managers to design fire management plans according to vegetation characteristics that are found important in controlling burn severity and prioritize management locations based on the relative importance of vegetation and topography.
NASA Astrophysics Data System (ADS)
Wu, Zhiwei; He, Hong S.; Liang, Yu; Cai, Longyan; Lewis, Bernard J.
2013-10-01
Fire is a dominant process in boreal forest landscapes and creates a spatial patch mosaic with different burn severities and age classes. Quantifying effects of vegetation and topography on burn severity provides a scientific basis on which forest fire management plans are developed to reduce catastrophic fires. However, the relative contribution of vegetation and topography to burn severity is highly debated especially under extreme weather conditions. In this study, we hypothesized that relationships of vegetation and topography to burn severity vary with fire size. We examined this hypothesis in a boreal forest landscape of northeastern China by computing the burn severity of 24 fire patches as the difference between the pre- and post-fire Normalized Difference Vegetation Index obtained from two Landsat TM images. The vegetation and topography to burn severity relationships were evaluated at three fire-size levels of small (<100 ha, n = 12), moderate (100-1,000 ha, n = 9), and large (>1,000 ha, n = 3). Our results showed that vegetation and topography to burn severity relationships were fire-size-dependent. The burn severity of small fires was primary controlled by vegetation conditions (e.g., understory cover), and the burn severity of large fires was strongly influenced by topographic conditions (e.g., elevation). For moderate fires, the relationships were complex and indistinguishable. Our results also indicated that the pattern trends of relative importance for both vegetation and topography factors were not dependent on fire size. Our study can help managers to design fire management plans according to vegetation characteristics that are found important in controlling burn severity and prioritize management locations based on the relative importance of vegetation and topography.
Selvi Dogan, F; Cottenet, J; Douvier, S; Sagot, P
2016-03-01
To evaluate the changes in the quality of life of patients after deep pelvic endometriosis surgery, with a French version of EHP-30 questionnaire, and the capacity of the EHP-30 to carry out this measurement. Study prospective monocentric, conducted in the obstetrics and gynecology department of the CHU Dijon during the period of October 2012 from October 2013. A EHP-30 questionnaire was given to patients before surgery. The same questionnaire was sent to their homes, away from surgery (3-6 months) to inform about their postoperative quality of life. The difference in preoperative and postoperative scores was tested using the test Wilcoxon signed ranks. A difference was considered significant if the p-value was less than or equal to 0.05. Sensitivity to change was calculated by the method of effect size (ES). The size of the effect is defined as the difference in mean preoperative and postoperative scores divided by the standard deviation of preoperative scores. A size effet of 0.20 indicates less change scores, of 0.50 a moderate change and of 0.80 a material change. We included 22 patients in total in the prospective analysis. The majority of patients had gynecological symptoms of dysmenorrhea with 69.7%, 75.7% and 75.7% dyspareunia chronic pelvic pain. Nineteen patients (57.6%) had gastro-intestinal symptoms. Urinary symptoms were less frequent. The results of the EHP-30 showed a significant improvement for the items "pain" (P=0.01), "control and powerlessness" (P=0.02), "emotional well-being" (P<0,01) "social relations" (P<0.01), "sexual intercourse" (P=0.03) and "relationship with the medical world" (P=0.05). We observed a non-significant improvement for the items "self-image" (P=0.44), "work" (P=0.48) and "relationships with children" (P=0.50). The size of the effect (ES) was low to high for all dimensions of the questionnaire, ranging from 0.1 to 0.6 for the entire group. A significant sensitivity to change was found for the items "pain" (ES=0.60), "control and powerlessness" (ES=0.62), "social relations" (ES=0.57). A moderate sensitivity to change was found for the items "emotional well-being" (ES=0.29), "relationship with the medical world" (ES=0.26). A low sensitivity to change was found for the items "relationships with children" (ES=0.06), "self-image" (ES=0.16), "work" (ES=0.18), "sexual intercourse" (ES=0.20). A size that is important to moderate effect corresponded to a statistically significant improvement of the score EHP-30. This study showed that the EHP-30 is a sensitive tool to change the health status and an appropriate instrument for the assessment of treatment effects in patients with deep pelvic endometriosis. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
A comparison between boat-based and diver-based methods for quantifying coral bleaching
Zawada, David G.; Ruzicka, Rob; Colella, Michael A.
2015-01-01
Recent increases in both the frequency and severity of coral bleaching events have spurred numerous surveys to quantify the immediate impacts and monitor the subsequent community response. Most of these efforts utilize conventional diver-based methods, which are inherently time-consuming, expensive, and limited in spatial scope unless they deploy large teams of scientifically-trained divers. In this study, we evaluated the effectiveness of the Along-Track Reef Imaging System (ATRIS), an automated image-acquisition technology, for assessing a moderate bleaching event that occurred in the summer of 2011 in the Florida Keys. More than 100,000 images were collected over 2.7 km of transects spanning four patch reefs in a 3-h period. In contrast, divers completed 18, 10-m long transects at nine patch reefs over a 5-day period. Corals were assigned to one of four categories: not bleached, pale, partially bleached, and bleached. The prevalence of bleaching estimated by ATRIS was comparable to the results obtained by divers, but only for corals > 41 cm in size. The coral size-threshold computed for ATRIS in this study was constrained by prevailing environmental conditions (turbidity and sea state) and, consequently, needs to be determined on a study-by-study basis. Both ATRIS and diver-based methods have innate strengths and weaknesses that must be weighed with respect to project goals.
Hughes, Elizabeth K; Gullone, Eleonora
2011-06-01
The study investigated the moderating role of emotion regulation (ER) in relationships between body image concerns and psychological symptomatology. A community sample of 533 boys and girls (11-20 years) completed measures assessing body image thoughts and feelings, domain-specific and general ER strategies, drive for thinness, and bulimic, depressive and anxiety symptoms. Results indicated that ER moderated relationships between body image concerns and both bulimic and depressive symptoms, but not relationships between body image concerns and drive for thinness or anxiety symptoms. Adolescents who reported frequent body image concerns were more likely to have higher levels of bulimic symptoms if they tended to use avoidance and internal dysfunctional ER strategies. Furthermore, adolescents who reported frequent body image concerns were more likely to have higher levels of depressive symptoms if they used positive rational acceptance and internal functional strategies infrequently. Implications of the findings for prevention and intervention are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Minas, Randall K; Poor, Morgan; Dennis, Alan R; Bartelt, Valerie L
2016-10-01
The link between intentions and action in weight control is weaker than previously thought, so recent research has called for further investigation of ways to improve weight control that bypass conscious intentions. Priming has been shown to have effects on individual behavior in a variety of contexts by influencing subconscious cognition. This paper investigates the effects of semantic priming using healthy body image, goal-oriented words on food consumption. The moderating role of both restrained eating and gender is investigated. 161 participants were involved in an experiment using a novel version of a scrambled sentence priming game. The outcome measure was the number of kilocalories consumed, examined using a between subjects ANCOVA with priming, gender, restrained eating index, self-reported BMI, and two interaction terms (primingxgender, and primingxrestrained eating index). There was no main effect of priming but there was an interaction of priming with gender. Females consumed significantly fewer kilocalories after being exposed to priming words related to a healthy body image (i.e. "slim", "fit,") compared to females receiving the neutral prime, with a medium effect size (d = 0.58). The body image prime did not significantly affect food intake for males, nor did it have a differential effect on restrained eaters. This study shows that priming can be an effective method for influencing females to reduce food intake, regardless of whether they are restrained or unrestrained eaters. Future studies could investigate whether different priming words related to a male's healthy body image goal (i.e. "buff," "muscles," etc.) would similarly reduce food intake for males. Copyright © 2016. Published by Elsevier Ltd.
NOAA GOES Geostationary Satellite Server
Size West CONUS IR Image MPEG | Loop Visible Full Size West CONUS VIS Image MPEG | Loop Water Vapor Full Size West Conus WV Image MPEG | Loop Alaska Infrared Full Size Alaska IR Image Loop | Color Infrared Full Size Hawaii IR Image Loop | Color Visible Full Size Hawaii VIS Image Loop Water Vapor Full
Goenka, Ajit H; Herts, Brian R; Dong, Frank; Obuchowski, Nancy A; Primak, Andrew N; Karim, Wadih; Baker, Mark E
2016-08-01
Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.
Two-dimensional phase unwrapping using robust derivative estimation and adaptive integration.
Strand, Jarle; Taxt, Torfinn
2002-01-01
The adaptive integration (ADI) method for two-dimensional (2-D) phase unwrapping is presented. The method uses an algorithm for noise robust estimation of partial derivatives, followed by a noise robust adaptive integration process. The ADI method can easily unwrap phase images with moderate noise levels, and the resulting images are congruent modulo 2pi with the observed, wrapped, input images. In a quantitative evaluation, both the ADI and the BLS methods (Strand et al.) were better than the least-squares methods of Ghiglia and Romero (GR), and of Marroquin and Rivera (MRM). In a qualitative evaluation, the ADI, the BLS, and a conjugate gradient version of the MRM method (MRMCG), were all compared using a synthetic image with shear, using 115 magnetic resonance images, and using 22 fiber-optic interferometry images. For the synthetic image and the interferometry images, the ADI method gave consistently visually better results than the other methods. For the MR images, the MRMCG method was best, and the ADI method second best. The ADI method was less sensitive to the mask definition and the block size than the BLS method, and successfully unwrapped images with shears that were not marked in the masks. The computational requirements of the ADI method for images of nonrectangular objects were comparable to only two iterations of many least-squares-based methods (e.g., GR). We believe the ADI method provides a powerful addition to the ensemble of tools available for 2-D phase unwrapping.
Ice Island calves off Petermann Glacier
2010-08-09
NASA image acquired August 5, 2010 On August 5, 2010, an enormous chunk of ice, roughly 97 square miles (251 square kilometers) in size, broke off the Petermann Glacier, along the northwestern coast of Greenland. The Canadian Ice Service detected the remote event within hours in near real-time data from the Moderate Resolution Imaging Spectroradiometer (MODIS) on NASA’s Aqua satellite. The Peterman Glacier lost about one-quarter of its 70-kilometer (40-mile) long floating ice shelf, said researchers who analyzed the satellite data at the University of Delaware. The Moderate Resolution Imaging Spectroradiometer (MODIS) on NASA’s Terra satellite captured these natural-color images of Petermann Glacier 18:05 UTC on August 5, 2010 (top), and 17:15 UTC on July 28, 2010 (bottom). The Terra image of the Petermann Glacier on August 5 was acquired almost 10 hours after the Aqua observation that first recorded the event. By the time Terra took this image, skies were less cloudy than they had been earlier in the day, and the oblong iceberg had broken free of the glacier and moved a short distance down the fjord. Icebergs calving off the Petermann Glacier are not unusual. Petermann Glacier’s floating ice tongue is the Northern Hemisphere’s largest, and it has occasionally calved large icebergs. The recently calved iceberg is the largest to form in the Arctic since 1962, said the University of Delaware. To read more and or to download the high res go here: www.nasa.gov/topics/earth/features/petermann-calve.html or Click here to see more images from NASA Goddard’s Earth Observatory NASA Earth Observatory image created by Jesse Allen and Robert Simmon, using data obtained from the Goddard Level 1 and Atmospheric Archive and Distribution System (LAADS). Caption by Holli Riebeek and Michon Scott. Instrument: Terra - MODIS NASA Goddard Space Flight Center is home to the nation's largest organization of combined scientists, engineers and technologists that build spacecraft, instruments and new technology to study the Earth, the sun, our solar system, and the universe. Follow us on Twitter Join us on Facebook
Srichandan, Haragobinda; Singh, Sradhanjali; Pathak, Ashish; Kim, Dong-Jin; Lee, Seoung-Won; Heyes, Graeme
2014-01-01
The present work investigated the leaching potential of moderately thermophilic bacteria in the recovery of metals from spent petroleum catalyst of varying particle sizes. The batch bioleaching experiments were conducted by employing a mixed consortium of moderate thermophilic bacteria at 45°C and by using five different particle sizes (from 45 to >2000 μm) of acetone-washed spent catalyst. The elemental mapping by FESEM confirmed the presence of Al, Ni, V and Mo along with sulfur in the spent catalyst. During bioleaching, Ni (92-97%) and V (81-91%) were leached in higher concentrations, whereas leaching yields of Al (23-38%) were found to be lowest in all particle sizes investigated. Decreasing the particle size from >2000 μm to 45-106 μm caused an increase in leaching yields of metals during initial hours. However, the final metals leaching yields were almost independent of particle sizes of catalyst. Leaching kinetics was observed to follow the diffusion-controlled model showing the linearity more close than the chemical control. The results of the present study suggested that bioleaching using moderate thermophilic bacteria was highly effective in removing the metals from spent catalyst. Moreover, bioleaching can be conducted using spent catalyst of higher particle size (>2000 μm), thus saving the grinding cost and making process attractive for larger scale application.
Mars Global Digital Dune Database: MC2-MC29
Hayward, Rosalyn K.; Mullins, Kevin F.; Fenton, L.K.; Hare, T.M.; Titus, T.N.; Bourke, M.C.; Colaprete, Anthony; Christensen, P.R.
2007-01-01
Introduction The Mars Global Digital Dune Database presents data and describes the methodology used in creating the database. The database provides a comprehensive and quantitative view of the geographic distribution of moderate- to large-size dune fields from 65? N to 65? S latitude and encompasses ~ 550 dune fields. The database will be expanded to cover the entire planet in later versions. Although we have attempted to include all dune fields between 65? N and 65? S, some have likely been excluded for two reasons: 1) incomplete THEMIS IR (daytime) coverage may have caused us to exclude some moderate- to large-size dune fields or 2) resolution of THEMIS IR coverage (100m/pixel) certainly caused us to exclude smaller dune fields. The smallest dune fields in the database are ~ 1 km2 in area. While the moderate to large dune fields are likely to constitute the largest compilation of sediment on the planet, smaller stores of sediment of dunes are likely to be found elsewhere via higher resolution data. Thus, it should be noted that our database excludes all small dune fields and some moderate to large dune fields as well. Therefore the absence of mapped dune fields does not mean that such dune fields do not exist and is not intended to imply a lack of saltating sand in other areas. Where availability and quality of THEMIS visible (VIS) or Mars Orbiter Camera narrow angle (MOC NA) images allowed, we classifed dunes and included dune slipface measurements, which were derived from gross dune morphology and represent the prevailing wind direction at the last time of significant dune modification. For dunes located within craters, the azimuth from crater centroid to dune field centroid was calculated. Output from a general circulation model (GCM) is also included. In addition to polygons locating dune fields, the database includes over 1800 selected Thermal Emission Imaging System (THEMIS) infrared (IR), THEMIS visible (VIS) and Mars Orbiter Camera Narrow Angle (MOC NA) images that were used to build the database. The database is presented in a variety of formats. It is presented as a series of ArcReader projects which can be opened using the free ArcReader software. The latest version of ArcReader can be downloaded at http://www.esri.com/software/arcgis/arcreader/download.html. The database is also presented in ArcMap projects. The ArcMap projects allow fuller use of the data, but require ESRI ArcMap? software. Multiple projects were required to accommodate the large number of images needed. A fuller description of the projects can be found in the Dunes_ReadMe file and the ReadMe_GIS file in the Documentation folder. For users who prefer to create their own projects, the data is available in ESRI shapefile and geodatabase formats, as well as the open Geographic Markup Language (GML) format. A printable map of the dunes and craters in the database is available as a Portable Document Format (PDF) document. The map is also included as a JPEG file. ReadMe files are available in PDF and ASCII (.txt) files. Tables are available in both Excel (.xls) and ASCII formats.
NASA Astrophysics Data System (ADS)
Schweiger, A. J.; Stern, H. L.; Stark, M.; Zhang, J.; Hwang, P.; Steele, M.
2013-12-01
Several key processes in the Marginal Ice Zone (MIZ) of the Arctic Ocean are related to the size of the ice floes, whose diameters range from meters to tens of kilometers. The floe size distribution (FSD) influences mechanical properties of the ice and thus its response to winds, currents, and waves, which is likely to modify the air-sea momentum transfer. The FSD also influences the air-sea heat transfer and the response of the MIZ ice cover to the thermal forcing. The FSD also has a significant role in lateral melting. No existing sea-ice/ocean models currently simulate the FSD in the MIZ. Significant uncertainties in FSD-related processes hinder model incorporation of the FSD, and model development must heavily depend on observations of the FSD for parameterization, calibration, and validation. To support the development and implementation of the FSD in the Marginal Ice Zone Modeling and Assimilation System (MIZMAS), we have conducted an analysis of the FSD in the Beaufort and Chukchi seas using three sources of satellite imagery: NASA's Moderate Resolution Imaging Spectroradiometer (MODIS) on the Terra and Aqua satellites, the Canadian Space Agency's synthetic aperture radar (SAR) on RADARSAT, and declassified National Technical Means imagery from the Global Fiducials Library (GFL) of the U.S. Geological Survey. The MODIS visible and short-wave infrared bands have a pixel size of 250 meters, and are only useful in cloud-free regions. The SAR imagery is unaffected by clouds and darkness, and has a pixel size of 50 meters. The GFL visible imagery, with a pixel size of 1 meter, is only useful in cloud-free regions. The resolution and spatial extent of the various image products allows us to identify ice floes of all sizes from 10 meters to 100 kilometers. The general procedure for identifying ice floes in the imagery is as follows: delineate cloud-free regions (if necessary); choose a threshold to separate ice from water, and create a binary image; apply the morphological erosion operation to separate floes that touch each other; identify contiguous sets of pixels (floes) by a recursive algorithm; and apply the morphological dilation operation to restore (approximately) the floes to their original sizes and shapes. Once the floes in an image have been identified, any number of properties may be calculated: the centroid, length, width, area, perimeter, orientation, convexity, etc. We calculate the mean caliper diameter as a simple, single measure of the size of a floe. We report results on the observed FSD in the Beaufort and Chukchi seas, including its seasonal evolution and spatial variability. We outline how the results will be used in model development and validation of the FSD in the MIZMAS.
X-ray optics for the LAMAR facility, an overview. [Large Area Modular Array of Reflectors
NASA Technical Reports Server (NTRS)
Gorenstein, P.
1979-01-01
The paper surveys the Large Area Modular Array of Reflectors (LAMAR), the concept of which is based on meeting two major requirements in X-ray astronomy, large collecting area and moderately good or better angular resolution for avoiding source confusion and imaging source fields. It is shown that the LAMAR provides the same sensitivity and signal to noise in imaging as a single large telescope having the same area and angular resolution but is a great deal less costly to develop, construct, and integrate into a space mission. Attention is also given to the LAMAR modular nature which will allow for an evolutionary development from a modest size array on Spacelab to a Shuttle launched free flyer. Finally, consideration is given to manufacturing methods which show promise of making LAMAR meet the criteria of good angular resolution, relatively low cost, and capability for fast volume production.
Preliminary Analysis of the Performance of the Landsat 8/OLI Land Surface Reflectance Product
NASA Technical Reports Server (NTRS)
Vermote, Eric; Justice, Chris; Claverie, Martin; Franch, Belen
2016-01-01
The surface reflectance, i.e., satellite derived top of atmosphere (TOA) reflectance corrected for the temporally, spatially and spectrally varying scattering and absorbing effects of atmospheric gases and aerosols, is needed to monitor the land surface reliably. For this reason, the surface reflectance, and not TOA reflectance, is used to generate the greater majority of global land products, for example, from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) sensors. Even if atmospheric effects are minimized by sensor design, atmospheric effects are still challenging to correct. In particular, the strong impact of aerosols in the visible and near infrared spectral range can be difficult to correct, because they can be highly discrete in space and time (e.g., smoke plumes) and because of the complex scattering and absorbing properties of aerosols that vary spectrally and with aerosol size, shape, chemistry and density.
Iyama, Yuji; Nakaura, Takeshi; Kidoh, Masafumi; Oda, Seitaro; Utsunomiya, Daisuke; Sakaino, Naritsugu; Tokuyasu, Shinichi; Osakabe, Hirokazu; Harada, Kazunori; Yamashita, Yasuyuki
2016-11-01
The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT). We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom. We reconstructed clinical and phantom studies with filtered back projection (FBP), hybrid iterative reconstruction (hybrid IR), and knowledge-based IMR. We measured effective dose of patients and compared CT number, image noise, and contrast noise ratio in ascending aorta of each reconstruction technique. We compared the relationship between image noise and body mass index for the clinical study, and object size for phantom study. The mean effective dose was 0.98 ± 0.25 mSv. The image noise of knowledge-based IMR images was significantly lower than those of FBP and hybrid IR images (knowledge-based IMR: 19.4 ± 2.8; FBP: 126.7 ± 35.0; hybrid IR: 48.8 ± 12.8, respectively) (P < .01). The contrast noise ratio of knowledge-based IMR images was significantly higher than those of FBP and hybrid IR images (knowledge-based IMR: 29.1 ± 5.4; FBP: 4.6 ± 1.3; hybrid IR: 13.1 ± 3.5, respectively) (P < .01). There were moderate correlations between image noise and body mass index in FBP (r = 0.57, P < .01) and hybrid IR techniques (r = 0.42, P < .01); however, these correlations were weak in knowledge-based IMR (r = 0.27, P < .01). Compared to FBP and hybrid IR, the knowledge-based IMR offers significant noise reduction and improvement in image quality in submillisievert radiation dose cardiac CT. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, G
2016-06-15
Purpose: Recently a new 2.5 megavoltage imaging beam has become available in a TrueBeam linear accelerator for image guidance. There is limited information available related to the beam characteristics. Commissioning dosimetric data of the new imaging is necessary for configuration of the beam in a treatment planning system in order to calculate imaging doses to patients resulting from this new imaging beam. The purpose of this study is to provide measured commissioning data recommended for a beam configuration in a treatment planning system. Methods: A recently installed TrueBeam linear accelerator is equipped with a new low energy photon beam withmore » a nominal energy of 2.5 MV which provides better image quality in addition to other therapeutic megavoltage beams. Dosimetric characteristics of the 2.5 MV are measured for commissioning. An ionization chamber was used to measure dosimetric data including depth-dose curves and dose profiles at different depths for field sizes ranging from 5×5 cm{sup 2} to 40×40 cm{sup 2}. Results: Although the new 2.5 MV beam is a flattening-filter-free (FFF) beam, its dose profiles are much flatter compared to a 6 MV FFF beam. The dose decrease at 20 cm away from the central axis is less than 30% for a 40×40 cm{sup 2} field. This moderately lower dose at off-axis distances benefits the imaging quality. The values of percentage depth-dose (PDD) curves are 53% and 63% for 10×10 cm{sup 2} and 40×40 cm{sup 2} fields respectively. The measured beam output is 0.85 cGy/MU for a reference field size at depth 5 cm obtained according to the AAPM TG-51 protocol. Conclusion: This systematically measured commissioning data is useful for configuring the new imaging beam in a treatment planning system for patient imaging dose calculations resulting from the application of this 2.5 MV beam which is commonly set as a default in imaging procedures.« less
Rizzardi, Anthony E; Zhang, Xiaotun; Vogel, Rachel Isaksson; Kolb, Suzanne; Geybels, Milan S; Leung, Yuet-Kin; Henriksen, Jonathan C; Ho, Shuk-Mei; Kwak, Julianna; Stanford, Janet L; Schmechel, Stephen C
2016-07-11
Digital image analysis offers advantages over traditional pathologist visual scoring of immunohistochemistry, although few studies examining the correlation and reproducibility of these methods have been performed in prostate cancer. We evaluated the correlation between digital image analysis (continuous variable data) and pathologist visual scoring (quasi-continuous variable data), reproducibility of each method, and association of digital image analysis methods with outcomes using prostate cancer tissue microarrays (TMAs) stained for estrogen receptor-β2 (ERβ2). Prostate cancer TMAs were digitized and evaluated by pathologist visual scoring versus digital image analysis for ERβ2 staining within tumor epithelium. Two independent analysis runs were performed to evaluate reproducibility. Image analysis data were evaluated for associations with recurrence-free survival and disease specific survival following radical prostatectomy. We observed weak/moderate Spearman correlation between digital image analysis and pathologist visual scores of tumor nuclei (Analysis Run A: 0.42, Analysis Run B: 0.41), and moderate/strong correlation between digital image analysis and pathologist visual scores of tumor cytoplasm (Analysis Run A: 0.70, Analysis Run B: 0.69). For the reproducibility analysis, there was high Spearman correlation between pathologist visual scores generated for individual TMA spots across Analysis Runs A and B (Nuclei: 0.84, Cytoplasm: 0.83), and very high correlation between digital image analysis for individual TMA spots across Analysis Runs A and B (Nuclei: 0.99, Cytoplasm: 0.99). Further, ERβ2 staining was significantly associated with increased risk of prostate cancer-specific mortality (PCSM) when quantified by cytoplasmic digital image analysis (HR 2.16, 95 % CI 1.02-4.57, p = 0.045), nuclear image analysis (HR 2.67, 95 % CI 1.20-5.96, p = 0.016), and total malignant epithelial area analysis (HR 5.10, 95 % CI 1.70-15.34, p = 0.004). After adjusting for clinicopathologic factors, only total malignant epithelial area ERβ2 staining was significantly associated with PCSM (HR 4.08, 95 % CI 1.37-12.15, p = 0.012). Digital methods of immunohistochemical quantification are more reproducible than pathologist visual scoring in prostate cancer, suggesting that digital methods are preferable and especially warranted for studies involving large sample sizes.
Arısoy, Arif; Topçu, Selim; Demirelli, Selami; Altunkaş, Fatih; Karayakalı, Metin; Çelik, Ataç; Tanboğa, İbrahim Halil; Aksakal, Enbiya; Sevimli, Serdar; Gürlertop, Hanefi Yekta
2015-11-25
The aim of this study was to evaluate right ventricle (RV) functions using echocardiography in healthy subjects who migrated from the sea level to moderate altitude (1890 m). The prospective observational in this study population consisted of 33 healthy subjects (23 men; mean age 20.4±3.2 years) who migrated from the sea level to a moderate altitude (Erzurum city centre, 1890 m above sea level) for long-term stay. Subjects underwent echocardiographic evaluation within the first 48 h of exposure to the moderate altitude and at the sixth month of arrival. Conventional echocardiographic parameters such as RV sizes and areas, systolic, and diastolic functional indices [fractional area change (FAC), tricuspid flow velocities, myocardial performance index (MPI), and tricuspid annular plane systolic excursion (TAPSE)] were obtained. Systolic (S) and diastolic (E', A') velocities were acquired from the apical fourchamber view using tissue Doppler imaging. Kolmogorov-Smirnov test, student's t-test, Wilcoxon test, and chi-square test were used in this study. There were no significant changes in RV size, FAC, MPI, TAPSE, inferior inspiratory vena cava collapse, tricuspid E velocity, and tricuspid annulus E' velocity. Compared with the baseline, there was a significant increase in mean pulmonary artery pressure (p=0.001); RV end systolic area (p=0.014); right atrial end diastolic area (p=0.021); tricuspid A velocity (p=0.013); tricuspid annulus S and A' velocity (p=0.031 and p=0.006, respectively); and RV free wall S, E', and A' velocity (p=0.007, p<0.001, and p=0.007 respectively) at the sixth month. Also, there was a significant decrease in tricuspid E/A ratio (1.61±0.3 vs. 1.45±0.2, p=0.038) and tricuspid annulus E'/A' ratio (1.52±0.5 vs. 1.23±0.4, p=0.002) at the sixth month. Our study revealed that right ventricular diastolic function was altered while the systolic function was preserved in healthy subjects who migrated from the sea level to a moderate altitude.
Thermoacoustic Contrast of Prostate Cancer due to Heating by Very High Frequency Irradiation
Hull, D; Thomas, M; Griep, SK; Jacobsohn, K; See, WA
2015-01-01
Applying the thermoacoustic (TA) effect to diagnostic imaging was first proposed in the 1980s. The object under test is irradiated by high-power pulses of electromagnetic energy, which heat tissue and cause thermal expansion. Outgoing TA pressure pulses are detected by ultrasound transducers and reconstructed to provide images of the object. The TA contrast mechanism is strongly dependent upon the frequency of the irradiating electromagnetic pulse. When very high frequency (VHF) electromagnetic irradiation is utilized, TA signal production is driven by ionic content. Prostatic fluids contain high levels of ionic metabolites, including citrate, zinc, calcium, and magnesium. Healthy prostate glands produce more ionic metabolites than diseased glands. VHF pulses are therefore expected to generate stronger TA signal in healthy prostate glands than in diseased glands. A benchtop system for performing ex vivo thermoacoustic computed tomography with VHF energy is described and images are presented. The system utilizes irradiation pulses of 700 ns duration exceeding 20 kW power. Reconstructions frequently visualize anatomic landmarks such as the urethra and verumontanum. TA reconstructions from three freshly excised human prostate glands with little, moderate, and severe cancerous involvement are compared with histology. TA signal strength is negatively correlated with percent cancerous involvement in this small sample size. For the 45 regions of interest analyzed, a reconstruction value of 0.4 mV provides 100% sensitivity but only 29% specificity. This sample size is far too small to draw sweeping conclusions, but the results warrant a larger volume study including comparison of TA images to the gold standard, histology. PMID:25554968
Thermoacoustic contrast of prostate cancer due to heating by very high frequency irradiation.
Patch, S K; Hull, D; Thomas, M; Griep, S K; Jacobsohn, K; See, W A
2015-01-21
Applying the thermoacoustic (TA) effect to diagnostic imaging was first proposed in the 1980s. The object under test is irradiated by high-power pulses of electromagnetic energy, which heat tissue and cause thermal expansion. Outgoing TA pressure pulses are detected by ultrasound transducers and reconstructed to provide images of the object. The TA contrast mechanism is strongly dependent upon the frequency of the irradiating electromagnetic pulse. When very high frequency (VHF) electromagnetic irradiation is utilized, TA signal production is driven by ionic content. Prostatic fluids contain high levels of ionic metabolites, including citrate, zinc, calcium, and magnesium. Healthy prostate glands produce more ionic metabolites than diseased glands. VHF pulses are therefore expected to generate stronger TA signal in healthy prostate glands than in diseased glands. A benchtop system for performing ex vivo TA computed tomography with VHF energy is described and images are presented. The system utilizes irradiation pulses of 700 ns duration exceeding 20 kW power. Reconstructions frequently visualize anatomic landmarks such as the urethra and verumontanum. TA reconstructions from three freshly excised human prostate glands with little, moderate, and severe cancerous involvement are compared with histology. TA signal strength is negatively correlated with percent cancerous involvement in this small sample size. For the 45 regions of interest analyzed, a reconstruction value of 0.4 mV provides 100% sensitivity but only 29% specificity. This sample size is far too small to draw sweeping conclusions, but the results warrant a larger volume study including comparison of TA images to the gold standard, histology.
Morphological analysis of pore size and connectivity in a thick mixed-culture biofilm.
Rosenthal, Alex F; Griffin, James S; Wagner, Michael; Packman, Aaron I; Balogun, Oluwaseyi; Wells, George F
2018-05-19
Morphological parameters are commonly used to predict transport and metabolic kinetics in biofilms. Yet, quantification of biofilm morphology remains challenging due to imaging technology limitations and lack of robust analytical approaches. We present a novel set of imaging and image analysis techniques to estimate internal porosity, pore size distributions, and pore network connectivity to a depth of 1 mm at a resolution of 10 µm in a biofilm exhibiting both heterotrophic and nitrifying activity. Optical coherence tomography (OCT) scans revealed an extensive pore network with diameters as large as 110 µm directly connected to the biofilm surface and surrounding fluid. Thin section fluorescence in situ hybridization microscopy revealed ammonia oxidizing bacteria (AOB) distributed through the entire thickness of the biofilm. AOB were particularly concentrated in the biofilm around internal pores. Areal porosity values estimated from OCT scans were consistently lower than those estimated from multiphoton laser scanning microscopy, though the two imaging modalities showed a statistically significant correlation (r = 0.49, p<0.0001). Estimates of areal porosity were moderately sensitive to grey level threshold selection, though several automated thresholding algorithms yielded similar values to those obtained by manually thresholding performed by a panel of environmental engineering researchers (±25% relative error). These findings advance our ability to quantitatively describe the geometry of biofilm internal pore networks at length scales relevant to engineered biofilm reactors and suggest that internal pore structures provide crucial habitat for nitrifier growth. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Rheumatoid myositis, myth or reality? A clinical, imaging and histological study.
Ancuţa, Codrina; Pomîrleanu, Daniela Cristina; Anton, Carmen Rodica; Moraru, Eovelina; Anton, Emil; Chirieac, Rodica Marieta; Ancuţa, Eugen
2014-01-01
Rheumatoid myositis (RM) is still poorly characterized, albeit the concept of muscle involvement in rheumatoid arthritis (RA) is well-recognized as being driven by a wide range of causes including inflammation, drugs, impaired joint flexibility, sedentarism. To describe clinical, serological, imaging and histological pattern of RM. This is a retrospective study on eight RM selected from a cohort of one hundred and three RA systematically assessed for skeletal muscle involvement. Data collected included clinical, serum muscle enzymes, muscle imaging and biopsy (Hematoxylin-Eosin, modified Gömöri trichrome staining). Routine muscle histology indicated both non-specific muscle fiber damage (changes in fiber size and internal structure: pleomorphic mitochondria, dilated sarcotubular system, multiple internal or subsarcommal nuclei; abnormal fiber types distribution: trend towards type II; atrophy; degenerative/regenerative modifications) and the presence of inflammatory deposits in all patients (mild to moderate, patchy B- and T-cells infiltrates, mainly perivascular and endomysial, but also in the perimysial region classified as polymyositis-like deposits). High levels of serum muscle enzymes, abnormal EMG (short duration, small amplitude, polyphasic motor unit action potentials) without insertional activity and fibrillations, active inflammation on both Doppler ultrasound and MRI were commonly reported. Traditional analysis of muscle biopsy specimens (Hematoxylin-Eosin, modified Gömöri trichrome staining) is faraway unsatisfactory, only documenting changes in muscle fibers size, architecture, internal structure, and, possibly, detecting perivascular, perimysial or endomysial inflammatory deposits. Upcoming research should address the value of muscle imaging for the diagnosis and evaluation of treatment response and muscle function in rheumatoid myositis.
Floating Algae Blooms in the East China Sea
NASA Astrophysics Data System (ADS)
Qi, Lin; Hu, Chuanmin; Wang, Mengqiu; Shang, Shaoling; Wilson, Cara
2017-11-01
A floating algae bloom in the East China Sea was observed in Moderate Resolution Imaging Spectroradiometer (MODIS) imagery in May 2017. Using satellite imagery from MODIS, Visible Infrared Imaging Radiometer Suite, Geostationary Ocean Color Imager, and Ocean Land Imager, and combined with numerical particle tracing experiments and laboratory experiments, we examined the history of this bloom as well as similar blooms in previous years and attempted to trace the bloom source and identify the algae type. Results suggest that one bloom origin is offshore Zhejiang coast where algae slicks have appeared in satellite imagery almost every February-March since 2012. Following the Kuroshio Current and Taiwan Warm Current, these "initial" algae slicks are first transported to the northeast to reach South Korea (Jeju Island) and Japan coastal waters (up to 135°E) by early April 2017, and then transported to the northwest to enter the Yellow Sea by the end of April. The transport pathway covers an area known to be rich in Sargassum horneri, and spectral analysis suggests that most of the algae slicks may contain large amount of S. horneri. The bloom covers a water area of 160,000 km2 with pure algae coverage of 530 km2, which exceeds the size of most Ulva blooms that occur every May-July in the Yellow Sea. While blooms of smaller size also occurred in previous years and especially in 2015, the 2017 bloom is hypothesized to be a result of record-high water temperature, increased light availability, and continuous expansion of Porphyra aquaculture along the East China Sea coast.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasel, Stella, E-mail: Stella.Blasel@kgu.de; Hattingen, Elke; Berkefeld, Joachim
2009-07-15
The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions,more » with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.« less
Moore, Makeda; Masuda, Akihiko; Hill, Mary L; Goodnight, Bradley L
2014-12-01
Body image flexibility, a regulation process of openly and freely experiencing disordered eating thoughts and body dissatisfaction, has been found to be a buffering factor against disordered eating symptomatology. The present cross-sectional study investigates whether body image flexibility accounts for disordered eating behavior above and beyond disordered eating cognition, mindfulness, and psychological inflexibility in a sample of nonclinical women, and whether body image flexibility moderates the associations between these correlates and disordered eating behavior. Participants were 421 women, age 21±5.3 years old on average, who completed a web-based survey that included the self-report measures of interest. Results demonstrate the incremental effects of body image flexibility on disordered eating behavior above and beyond disordered eating cognition, mindfulness, and psychological inflexibility. Women with greater body image flexibility endorse disordered eating behavior less so than those with lower body image flexibility. Body image flexibility moderates the association between disordered eating cognition and disordered eating behavior; for women with greater body image flexibility, disordered eating cognition is not positively associated with disordered eating behavior. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gender Differences in Academic Self-Efficacy: A Meta-Analysis
ERIC Educational Resources Information Center
Huang, Chiungjung
2013-01-01
A meta-analysis of 187 studies containing 247 independent studies (N = 68,429) on gender differences in academic self-efficacy identified an overall effect size of 0.08, with a small difference favoring males. Moderator analysis demonstrated that content domain was a significant moderator in explaining effect size variation. Females displayed…
Bodner, Todd E.
2017-01-01
Wilkinson and Task Force on Statistical Inference (1999) recommended that researchers include information on the practical magnitude of effects (e.g., using standardized effect sizes) to distinguish between the statistical and practical significance of research results. To date, however, researchers have not widely incorporated this recommendation into the interpretation and communication of the conditional effects and differences in conditional effects underlying statistical interactions involving a continuous moderator variable where at least one of the involved variables has an arbitrary metric. This article presents a descriptive approach to investigate two-way statistical interactions involving continuous moderator variables where the conditional effects underlying these interactions are expressed in standardized effect size metrics (i.e., standardized mean differences and semi-partial correlations). This approach permits researchers to evaluate and communicate the practical magnitude of particular conditional effects and differences in conditional effects using conventional and proposed guidelines, respectively, for the standardized effect size and therefore provides the researcher important supplementary information lacking under current approaches. The utility of this approach is demonstrated with two real data examples and important assumptions underlying the standardization process are highlighted. PMID:28484404
Choi, Brian G; Mukherjee, Monica; Dala, Praveen; Young, Heather A; Tracy, Cynthia M; Katz, Richard J; Lewis, Jannet F
2011-12-01
Pocket-size ultrasound has increased echocardiographic portability, but expert point-of-care interpretation may not be readily available. The aim of this study was to test the hypothesis that remote interpretation on a smartphone with dedicated medical imaging software can be as accurate as on a workstation. Eighty-nine patients in a remote Honduran village underwent echocardiography by a nonexpert using a pocket-size ultrasound device. Images were sent for verification of point-of-care diagnosis to two expert echocardiographers in the United States reading on a workstation. Studies were then anonymized, randomly ordered, and reinterpreted on a smartphone with a dedicated, Health Insurance Portability and Accountability Act-compliant application. Point-of-care diagnosis was considered accurate if any abnormal finding was matched and categorized at the same level of severity (mild, moderate, or severe) by either expert interpretation. The mean age was 54 ± 23 years, and 57% of patients were women. The most common indications for echocardiography were arrhythmia (33%), cardiomyopathy (28%), and syncope (15%). Using the workstation, point-of-care diagnoses were changed in 38% of cases by expert overread (41% left ventricular function correction, 38% valvulopathy correction, 18% poor image quality). Expert interobserver agreement was excellent at 82%, with a Cohen's κ value of 0.82 (95% confidence interval, 0.70-0.94). Intraobserver agreement comparing interpretations on workstations and smartphones was 90%, with a Cohen's κ value of 0.86 (95% confidence interval, 0.76-0.97), signifying excellent intertechnology agreement. Remote expert echocardiographic interpretation can provide backup support to point-of-care diagnosis by nonexperts when read on a dedicated smartphone-based application. Mobile-to-mobile consultation may improve access in previously inaccessible locations to accurate echocardiographic interpretation by experienced cardiologists. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Stimulus Modality and Smoking Behavior: Moderating Role of Implicit Attitudes.
Ezeh, Valentine C; Mefoh, Philip
2015-07-20
This study investigated whether stimulus modality influences smoking behavior among smokers in South Eastern Nigeria and also whether implicit attitudes moderate the relationship between stimulus modality and smoking behavior. 60 undergraduate students of University of Nigeria, Nsukka were used. Participants were individually administered the IAT task as a measure of implicit attitude toward smoking and randomly assigned into either image condition that paired images of cigarette with aversive images of potential health consequences or text condition that paired images of cigarette with aversive texts of potential health consequences. A one- predictor and one-moderator binary logistic analysis indicates that stimulus modality significantly predicts smoking behavior (p = < .05) with those in the image condition choosing not to smoke with greater probability than the text condition. The interaction between stimulus modality and IAT scores was also significant (p = < .05). Specifically, the modality effect was larger for participants in the image group who held more negative implicit attitudes towards smoking. The finding shows the urgent need to introduce the use of aversive images of potential health consequences on cigarette packs in Nigeria.
Self-image of the Patients with Head and Neck Cancer: A Mixed Method Research
Nayak, Shalini G; Pai, Mamatha Shivananda; George, Linu Sara
2016-01-01
Aim: The aim of the study was to assess the self-image of the patients with head and neck cancers (HNCs) by using a mixed method research. Subjects and Methods: A mixed method approach and triangulation design was used with the aim of assessing the self-image of the patients with HNCs. Data was gathered by using self-administered self-image scale and structured interview. Nested sampling technique was adopted. Sample size for quantitative approach was 54 and data saturation was achieved with seven subjects for qualitative approach. Institutional Ethical Committee clearance was obtained. Results: The results of the study showed that 30 (56%) subjects had positive self-image and 24 (44%) had negative self-image. There was a moderate positive correlation between body image and integrity (r = 0.430, P = 0.001), weak positive correlation between body image and self-esteem (r = 0.270, P = 0.049), and no correlation between self-esteem and integrity (r = 0.203, P = 0.141). The participants also scored maximum (24/24) in the areas of body image and self-esteem. Similar findings were also observed in the phenomenological approach. The themes evolved were immaterial of outer appearance and desire of good health to all. Conclusion: The illness is long-term and impacts the individual 24 h a day. Understanding patients’ self-concept and living experiences of patients with HNC is important for the health care professionals to improve the care. PMID:27559264
Image-size differences worsen stereopsis independent of eye position
Vlaskamp, Björn N. S.; Filippini, Heather R.; Banks, Martin S.
2010-01-01
With the eyes in forward gaze, stereo performance worsens when one eye’s image is larger than the other’s. Near, eccentric objects naturally create retinal images of different sizes. Does this mean that stereopsis exhibits deficits for such stimuli? Or does the visual system compensate for the predictable image-size differences? To answer this, we measured discrimination of a disparity-defined shape for different relative image sizes. We did so for different gaze directions, some compatible with the image-size difference and some not. Magnifications of 10–15% caused a clear worsening of stereo performance. The worsening was determined only by relative image size and not by eye position. This shows that no neural compensation for image-size differences accompanies eye-position changes, at least prior to disparity estimation. We also found that a local cross-correlation model for disparity estimation performs like humans in the same task, suggesting that the decrease in stereo performance due to image-size differences is a byproduct of the disparity-estimation method. Finally, we looked for compensation in an observer who has constantly different image sizes due to differing eye lengths. She performed best when the presented images were roughly the same size, indicating that she has compensated for the persistent image-size difference. PMID:19271927
NASA Astrophysics Data System (ADS)
Hill, Jason E.; Matlock, Kevin; Pal, Ranadip; Nutter, Brian; Mitra, Sunanda
2016-03-01
Magnetic Resonance Imaging (MRI) is a vital tool in the diagnosis and characterization of multiple sclerosis (MS). MS lesions can be imaged with relatively high contrast using either Fluid Attenuated Inversion Recovery (FLAIR) or Double Inversion Recovery (DIR). Automated segmentation and accurate tracking of MS lesions from MRI remains a challenging problem. Here, an information theoretic approach to cluster the voxels in pseudo-colorized multispectral MR data (FLAIR, DIR, T2-weighted) is utilized to automatically segment MS lesions of various sizes and noise levels. The Improved Jump Method (IJM) clustering, assisted by edge suppression, is applied to the segmentation of white matter (WM), gray matter (GM), cerebrospinal fluid (CSF) and MS lesions, if present, into a subset of slices determined to be the best MS lesion candidates via Otsu's method. From this preliminary clustering, the modal data values for the tissues can be determined. A Euclidean distance is then used to estimate the fuzzy memberships of each brain voxel for all tissue types and their 50/50 partial volumes. From these estimates, binary discrete and fuzzy MS lesion masks are constructed. Validation is provided by using three synthetic MS lesions brains (mild, moderate and severe) with labeled ground truths. The MS lesions of mild, moderate and severe designations were detected with a sensitivity of 83.2%, and 88.5%, and 94.5%, and with the corresponding Dice similarity coefficient (DSC) of 0.7098, 0.8739, and 0.8266, respectively. The effect of MRI noise is also examined by simulated noise and the application of a bilateral filter in preprocessing.
Cervera, Vicente; Mai, Wilfried; Vite, Charles H; Johnson, Victoria; Dayrell-Hart, Betsy; Seiler, Gabriela S
2011-01-01
Cerebrovascular accidents, or strokes, and gliomas are common intraaxial brain lesions in dogs. An accurate differentiation of these two lesions is necessary for prognosis and treatment decisions. The magnetic resonance (MR) imaging characteristics of 21 dogs with a presumed cerebrovascular accident and 17 with a glioma were compared. MR imaging findings were reviewed retrospectively by three observers unaware of the final diagnosis. Statistically significant differences between the appearance of gliomas and cerebrovascular accidents were identified based on lesion location, size, mass effect, perilesional edema, and appearance of the apparent diffusion coefficient map. Gliomas were predominantly located in the cerebrum (76%) compared with presumed cerebrovascular accidents that were located mainly in the cerebellum, thalamus, caudate nucleus, midbrain, and brainstem (76%). Gliomas were significantly larger compared with presumed cerebrovascular accidents and more commonly associated with mass effect and perilesional edema. Wedge-shaped lesions were seen only in 19% of presumed cerebrovascular accidents. Between the three observers, 10-47% of the presumed cerebrovascular accidents were misdiagnosed as gliomas, and 0-12% of the gliomas were misdiagnosed as cerebrovascular accidents. Diffusion weighted imaging increased the accuracy of the diagnosis for both lesions. Agreement between observers was moderate (kappa = 0.48, P < 0.01).
Study on ice cloud optical thickness retrieval with MODIS IR spectral bands
NASA Astrophysics Data System (ADS)
Zhang, Hong; Li, Jun
2005-01-01
The operational Moderate-Resolution Imaging Spectroradiometer (MODIS) products for cloud properties such as cloud-top pressure (CTP), effective cloud amount (ECA), cloud particle size (CPS), cloud optical thickness (COT), and cloud phase (CP) have been available for users globally. An approach to retrieve COT is investigated using MODIS infrared (IR) window spectral bands (8.5 mm, 11mm, and 12 mm). The COT retrieval from MODIS IR bands has the potential to provide microphysical properties with high spatial resolution during night. The results are compared with those from operational MODIS products derived from the visible (VIS) and near-infrared (NIR) bands during day. Sensitivity of COT to MODIS spectral brightness temperature (BT) and BT difference (BTD) values is studied. A look-up table is created from the cloudy radiative transfer model accounting for the cloud absorption and scattering for the cloud microphysical property retrieval. The potential applications and limitations are also discussed. This algorithm can be applied to the future imager systems such as Visible/Infrared Imager/Radiometer Suite (VIIRS) on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) and Advanced Baseline Imager (ABI) on the Geostationary Operational Environmental Satellite (GOES)-R.
Demonstration and evaluation of a method for assessing mediated moderation.
Morgan-Lopez, Antonio A; MacKinnon, David P
2006-02-01
Mediated moderation occurs when the interaction between two variables affects a mediator, which then affects a dependent variable. In this article, we describe the mediated moderation model and evaluate it with a statistical simulation using an adaptation of product-of-coefficients methods to assess mediation. We also demonstrate the use of this method with a substantive example from the adolescent tobacco literature. In the simulation, relative bias (RB) in point estimates and standard errors did not exceed problematic levels of +/- 10% although systematic variability in RB was accounted for by parameter size, sample size, and nonzero direct effects. Power to detect mediated moderation effects appears to be severely compromised under one particular combination of conditions: when the component variables that make up the interaction terms are correlated and partial mediated moderation exists. Implications for the estimation of mediated moderation effects in experimental and nonexperimental research are discussed.
Accuracy of self- and parental perception of overweight among Latino preadolescents.
Intagliata, Valentina; Ip, Edward H; Gesell, Sabina B; Barkin, Shari L
2008-01-01
This investigation examines self-perception and parental perception of child body size and factors associated with accurate parental perception of child body size. Latino at-risk for overweight (AROW) and/or overweight preadolescent children (ages 8-11 years) along with their parents were recruited (N=123 dyads). Children's body mass index (BMI) was measured but not discussed before participants were shown pictures of body sizes and asked to select the image that represented the child's body. The correlation between the child's body size selection and the child's actual BMI was 0.117 (p=0.20) whereas the correlation between the parent's assessment of the child's body size and the child's actual BMI was 0.470 (p<0.001). Logistic regression revealed that only parental education level (> or =college) was associated with a more accurate parental perception of their child's body size (OR: 0.11/95% CI: 0.01, 0.89) while child's sex, parental BMI, and parental health status were not associated with a perception that corresponded to the child's BMI. The sample was drawn from a single community clinic in Forsyth County which serves a large population of newer Latino immigrants in the county. The results indicate that (1) Latino AROW/overweight preadolescent children do not have an accurate perception of their own body size; (2) Latino parents have a more accurate perception of their child's body size with a moderately sized correlation suggesting that their perception of their child's body size is frequently inaccurate; and (3) Latino parents with higher education perceive their child's body size more accurately than less educated parents.
Low Level Laser Therapy for Traumatic Brain Injury
2015-10-01
resonance imaging as the primary outcome measure. The second objective is a series of preclinical (mouse) investigations to decipher the mechanisms of LLLT...abnormal imaging (matching DoD definition of moderate TBI) and an anticipated hospital admission of 3 days or longer. We ran the study with these...moderate TBIs fall within the GCS13-15 with abnormal imaging category (instead of GCS9-12). These patients are typically admitted to the ED
Effect of restoration volume on stresses in a mandibular molar: a finite element study.
Wayne, Jennifer S; Chande, Ruchi; Porter, H Christian; Janus, Charles
2014-10-01
There can be significant disagreement among dentists when planning treatment for a tooth with a failing medium-to-large--sized restoration. The clinician must determine whether the restoration should be replaced or treated with a crown, which covers and protects the remaining weakened tooth structure during function. The purpose of this study was to evaluate the stresses generated in different sized amalgam restorations via a computational modeling approach and reveal whether a predictable pattern emerges. A computer tomography scan was performed of an extracted mandibular first molar, and the resulting images were imported into a medical imaging software package for tissue segmentation. The software was used to separate the enamel, dentin, and pulp cavity through density thresholding and surface rendering. These tissue structures then were imported into 3-dimensional computer-aided design software in which material properties appropriate to the tissues in the model were assigned. A static finite element analysis was conducted to investigate the stresses that result from normal occlusal forces. Five models were analyzed, 1 with no restoration and 4 with increasingly larger restoration volume proportions: a normal-sized tooth, a small-sized restoration, 2 medium-sized restorations, and 1 large restoration as determined from bitewing radiographs and occlusal surface digital photographs. The resulting von Mises stresses for dentin-enamel of the loaded portion of the tooth grew progressively greater as the size of the restoration increased. The average stress in the normal, unrestored tooth was 4.13 MPa, whereas the smallest restoration size increased this stress to 5.52 MPa. The largest restoration had a dentin-enamel stress of 6.47 MPa. A linear correlation existed between restoration size and dentin-enamel stress, with an R(2) of 0.97. A larger restoration volume proportion resulted in higher dentin-enamel stresses under static loading. A comparison of the von Mises stresses to the yield strengths of the materials revealed a relationship between a tooth's restoration volume proportion and the potential for failure, although factors other than restoration volume proportion may also impact the stresses generated in moderate-sized restorations. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Xiucheng; Chen, Li
2017-04-01
Urban surface water is characterized by complex surface continents and small size of water bodies, and the mapping of urban surface water is currently a challenging task. The moderate-resolution remote sensing satellites provide effective ways of monitoring surface water. This study conducts an exploratory evaluation on the performance of the newly available Sentinel-2A multispectral instrument (MSI) imagery for detecting urban surface water. An automatic framework that integrates pixel-level threshold adjustment and object-oriented segmentation is proposed. Based on the automated workflow, different combinations of visible, near infrared, and short-wave infrared bands in Sentinel-2 image via different water indices are first compared. Results show that object-level modified normalized difference water index (MNDWI with band 11) and automated water extraction index are feasible in urban surface water mapping for Sentinel-2 MSI imagery. Moreover, comparative results are obtained utilizing optimal MNDWI from Sentinel-2 and Landsat 8 images, respectively. Consequently, Sentinel-2 MSI achieves the kappa coefficient of 0.92, compared with that of 0.83 from Landsat 8 operational land imager.
ERIC Educational Resources Information Center
Skalická, Vera; Belsky, Jay; Stenseng, Frode; Wichstrøm, Lars
2015-01-01
In this Norwegian study, bidirectional relations between children's behavior problems and child-teacher conflict and closeness were examined, and the possibility of moderation of these associations by child-care group size was tested. Eight hundred and nineteen 4-year-old children were followed up in first grade. Results revealed reciprocal…
Effect of Team Size in Soccer on Moderate to Vigorous Physical Activity
ERIC Educational Resources Information Center
Arnett, Mark G.
2004-01-01
The purpose of this study was to compare the percentages of moderate to vigorous physical activity (MVPA) in soccer games with different team sizes. Twenty-two university physical education majors evenly divided between males and females volunteered for the study. Students were blind to the purpose of the study. Data were collected over three…
Zhu, Chunmao; Kobayashi, Hideki; Kanaya, Yugo; Saito, Masahiko
2017-07-05
Pollutants emitted from wildfires in boreal Eurasia can be transported to the Arctic, and their subsequent deposition could accelerate global warming. The Moderate Resolution Imaging Spectroradiometer (MODIS) MCD64A1 burned area product is the basis of fire emission products. However, uncertainties due to the "moderate resolution" (500 m) characteristic of the MODIS sensor could be introduced. Here, we present a size-dependent validation of MCD64A1 with reference to higher resolution (better than 30 m) satellite products (Landsat 7 ETM+, RapidEye, WorldView-2, and GeoEye-1) for six ecotypes over 12 regions of boreal Eurasia. We considered the 2012 boreal Eurasia burning season when severe wildfires occurred and when Arctic sea ice extent was historically low. Among the six ecotypes, we found MCD64A1 burned areas comprised only 13% of the reference products in croplands because of inadequate detection of small fires (<100 ha). Our results indicate that over all ecotypes, the actual burned area in boreal Eurasia (15,256 km 2 ) could have been ~16% greater than suggested by MCD64A1 (13,187 km 2 ) when applying the correction factors proposed in this study. This implies the effects of wildfire emissions in boreal Eurasia on Arctic warming could be greater than currently estimated.
The Development of Midlatitude Cirrus Models for MODIS Using FIRE-I, FIRE-II, and ARM In Situ Data
NASA Technical Reports Server (NTRS)
Nasiri, Shaima L.; Baum, Bryan A.; Heymsfield, Andrew J.; Yang, Ping; Poellot, Michael R.; Kratz, David P.; Hu, Yong-Xiang
2002-01-01
Detailed in situ data from cirrus clouds have been collected during dedicated field Campaigns, but the use of the size and habit distribution data has been lagging in the development of more realistic cirrus scattering models. In this study, the authors examine the use of in situ cirrus data collected during three field campaigns to develop more realistic midlatitude cirrus microphysical models. Data are used from the First International Satellite Cloud Climatology Project (ISCCP) Regional Experiment (FIRE)-I (1986) and FIRE-II (1991) campaigns and from a recent Atmospheric Radiation Measurement (ARM) Program campaign held in March-April of 2000. The microphysical models are based on measured vertical distributions of both particle size and particle habit and are used to develop new scattering models for a suite of moderate-resolution imaging spectroradiometer (MODIS) bands spanning visible. near-infrared, and infrared wavelengths. The sensitivity of the resulting scattering properties to the underlying assumptions of the assumed particle size and habit distributions are examined. It is found that the near-infrared bands are sensitive not only to the discretization of the size distribution but also to the assumed habit distribution. In addition. the results indicate that the effective diameter calculated from a given size distribution tends to be sensitive to the number of size bins that are used to discretize the data and also to the ice-crystal habit distribution.
Clear-Sky Narrowband Albedo Datasets Derived from Modis Data
NASA Astrophysics Data System (ADS)
Chen, Y.; Minnis, P.; Sun-Mack, S.; Arduini, R. F.; Hong, G.
2013-12-01
Satellite remote sensing of clouds requires an accurate estimate of the clear-sky radiances for a given scene to detect clouds and aerosols and to retrieve their microphysical properties. Knowing the spatial and angular variability of clear-sky albedo is essential for predicting the clear-sky radiance at solar wavelengths. The Clouds and the Earth's Radiant Energy System (CERES) Project uses the near-infrared (NIR; 1.24, 1.6 or 2.13 μm) and visible (VIS; 0.63 μm) channels available on the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS) to help identify clouds and retrieve their properties. Generally, clear-sky albedo for a given surface type is determined for conditions when the vegetation is either thriving or dormant and free of snow. The clear-sky albedos are derived using a radiative transfer parameterization of the impact of the atmosphere, including aerosols, on the observed reflectances. This paper presents the method of generating monthly clear-sky overhead albedo maps for both snow-free and snow-covered surfaces of these channels using one year of MODIS (Moderate Resolution Imaging Spectroradiometer) CERES products. Maps of 1.24 and 1.6 μm are being used as the background to help retrieve cloud properties (e.g., effective particle size, optical depth) in CERES cloud retrievals in both snow-free and snow-covered conditions.
Baranowski, Tom; Baranowski, Janice C; Watson, Kathleen B; Martin, Shelby; Beltran, Alicia; Islam, Noemi; Dadabhoy, Hafza; Adame, Su-heyla; Cullen, Karen; Thompson, Debbe; Buday, Richard; Subar, Amy
2011-03-01
To test the effect of image size and presence of size cues on the accuracy of portion size estimation by children. Children were randomly assigned to seeing images with or without food size cues (utensils and checked tablecloth) and were presented with sixteen food models (foods commonly eaten by children) in varying portion sizes, one at a time. They estimated each food model's portion size by selecting a digital food image. The same food images were presented in two ways: (i) as small, graduated portion size images all on one screen or (ii) by scrolling across large, graduated portion size images, one per sequential screen. Laboratory-based with computer and food models. Volunteer multi-ethnic sample of 120 children, equally distributed by gender and ages (8 to 13 years) in 2008-2009. Average percentage of correctly classified foods was 60·3 %. There were no differences in accuracy by any design factor or demographic characteristic. Multiple small pictures on the screen at once took half the time to estimate portion size compared with scrolling through large pictures. Larger pictures had more overestimation of size. Multiple images of successively larger portion sizes of a food on one computer screen facilitated quicker portion size responses with no decrease in accuracy. This is the method of choice for portion size estimation on a computer.
Lauenstein, Thomas; Ramirez-Garrido, Francisco; Kim, Young Hoon; Rha, Sung Eun; Ricke, Jens; Phongkitkarun, Sith; Boettcher, Joachim; Gupta, Rajan T.; Korpraphong, Pornpim; Tanomkiat, Wiwatana; Furtner, Julia; Liu, Peter S.; Henry, Maren; Endrikat, Jan
2015-01-01
Objective The objective of this study was to assess the risk of gadoxetate disodium in liver imaging for the development of nephrogenic systemic fibrosis (NSF) in patients with moderate to severe renal impairment. Materials and Methods We performed a prospective, multicenter, nonrandomized, open-label phase 4 study in 35 centers from May 2009 to July 2013. The study population consisted of patients with moderate to severe renal impairment scheduled for liver imaging with gadoxetate disodium. All patients received a single intravenous bolus injection of 0.025-mmol/kg body weight of liver-specific gadoxetate disodium. The primary target variable was the number of patients who develop NSF within a 2-year follow-up period. Results A total of 357 patients were included, with 85 patients with severe and 193 patients with moderate renal impairment, which were the clinically most relevant groups. The mean time period from diagnosis of renal disease to liver magnetic resonance imaging (MRI) was 1.53 and 5.46 years in the moderate and severe renal impairment cohort, respectively. Overall, 101 patients (28%) underwent additional contrast-enhanced MRI with other gadolinium-based MRI contrast agents within 12 months before the start of the study or in the follow-up. No patient developed symptoms conclusive of NSF within the 2-year follow-up. Conclusions Gadoxetate disodium in patients with moderate to severe renal impairment did not raise any clinically significant safety concern. No NSF cases were observed. PMID:25756684
Automated image analysis of placental villi and syncytial knots in histological sections.
Kidron, Debora; Vainer, Ifat; Fisher, Yael; Sharony, Reuven
2017-05-01
Delayed villous maturation and accelerated villous maturation diagnosed in histologic sections are morphologic manifestations of pathophysiological conditions. The inter-observer agreement among pathologists in assessing these conditions is moderate at best. We investigated whether automated image analysis of placental villi and syncytial knots could improve standardization in diagnosing these conditions. Placentas of antepartum fetal death at or near term were diagnosed as normal, delayed or accelerated villous maturation. Histologic sections of 5 cases per group were photographed at ×10 magnification. Automated image analysis of villi and syncytial knots was performed, using ImageJ public domain software. Analysis of hundreds of histologic images was carried out within minutes on a personal computer, using macro commands. Compared to normal placentas, villi from delayed maturation were larger and fewer, with fewer and smaller syncytial knots. Villi from accelerated maturation were smaller. The data were further analyzed according to horizontal placental zones and groups of villous size. Normal placentas can be discriminated from placentas of delayed or accelerated villous maturation using automated image analysis. Automated image analysis of villi and syncytial knots is not equivalent to interpretation by the human eye. Each method has advantages and disadvantages in assessing the 2-dimensional histologic sections representing the complex, 3-dimensional villous tree. Image analysis of placentas provides quantitative data that might help in standardizing and grading of placentas for diagnostic and research purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of a screening tool for staging of diabetic retinopathy in fundus images
NASA Astrophysics Data System (ADS)
Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Bency, Mayur Joseph; Rangayyan, Rangaraj M.; Bansal, Reema; Gupta, Amod
2015-03-01
Diabetic retinopathy is a condition of the eye of diabetic patients where the retina is damaged because of long-term diabetes. The condition deteriorates towards irreversible blindness in extreme cases of diabetic retinopathy. Hence, early detection of diabetic retinopathy is important to prevent blindness. Regular screening of fundus images of diabetic patients could be helpful in preventing blindness caused by diabetic retinopathy. In this paper, we propose techniques for staging of diabetic retinopathy in fundus images using several shape and texture features computed from detected microaneurysms, exudates, and hemorrhages. The classification accuracy is reported in terms of the area (Az) under the receiver operating characteristic curve using 200 fundus images from the MESSIDOR database. The value of Az for classifying normal images versus mild, moderate, and severe nonproliferative diabetic retinopathy (NPDR) is 0:9106. The value of Az for classification of mild NPDR versus moderate and severe NPDR is 0:8372. The Az value for classification of moderate NPDR and severe NPDR is 0:9750.
Planning JWST NIRSpec MSA spectroscopy using NIRCam pre-images
NASA Astrophysics Data System (ADS)
Beck, Tracy L.; Ubeda, Leonardo; Kassin, Susan A.; Gilbert, Karoline; Karakla, Diane M.; Reid, I. N.; Blair, William P.; Keyes, Charles D.; Soderblom, D. R.; Peña-Guerrero, Maria A.
2016-07-01
The Near-Infrared Spectrograph (NIRSpec) is the work-horse spectrograph at 1-5microns for the James Webb Space Telescope (JWST). A showcase observing mode of NIRSpec is the multi-object spectroscopy with the Micro-Shutter Arrays (MSAs), which consist of a quarter million tiny configurable shutters that are 0. ''20×0. ''46 in size. The NIRSpec MSA shutters can be opened in adjacent rows to create flexible and positionable spectroscopy slits on prime science targets of interest. Because of the very small shutter width, the NIRSpec MSA spectral data quality will benefit significantly from accurate astrometric knowledge of the positions of planned science sources. Images acquired with the Hubble Space Telescope (HST) have the optimal relative astrometric accuracy for planning NIRSpec observations of 5-10 milli-arcseconds (mas). However, some science fields of interest might have no HST images, galactic fields can have moderate proper motions at the 5mas level or greater, and extragalactic images with HST may have inadequate source information at NIRSpec wavelengths beyond 2 microns. Thus, optimal NIRSpec spectroscopy planning may require pre-imaging observations with the Near-Infrared Camera (NIRCam) on JWST to accurately establish source positions for alignment with the NIRSpec MSAs. We describe operational philosophies and programmatic considerations for acquiring JWST NIRCam pre-image observations for NIRSpec MSA spectroscopic planning within the same JWST observing Cycle.
Practical Weak-lensing Shear Measurement with Metacalibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheldon, Erin S.; Huff, Eric M.
2017-05-20
Metacalibration is a recently introduced method to accurately measure weak gravitational lensing shear using only the available imaging data, without need for prior information about galaxy properties or calibration from simulations. The method involves distorting the image with a small known shear, and calculating the response of a shear estimator to that applied shear. The method was shown to be accurate in moderate-sized simulations with galaxy images that had relatively high signal-to-noise ratios, and without significant selection effects. In this work we introduce a formalism to correct for both shear response and selection biases. We also observe that for imagesmore » with relatively low signal-to-noise ratios, the correlated noise that arises during the metacalibration process results in significant bias, for which we develop a simple empirical correction. To test this formalism, we created large image simulations based on both parametric models and real galaxy images, including tests with realistic point-spread functions. We varied the point-spread function ellipticity at the five-percent level. In each simulation we applied a small few-percent shear to the galaxy images. We introduced additional challenges that arise in real data, such as detection thresholds, stellar contamination, and missing data. We applied cuts on the measured galaxy properties to induce significant selection effects. Using our formalism, we recovered the input shear with an accuracy better than a part in a thousand in all cases.« less
Petretta, Robert; Strelzow, Jason; Ohly, Nicholas E; Misur, Peter; Masri, Bassam A
2015-12-01
Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. Level III, diagnostic study.
Deem, Samuel; Defade, Brian; Modak, Asmita; Emmett, Mary; Martinez, Fred; Davalos, Julio
2011-10-01
To compare the outcomes of percutaneous nephrolithotomy (PNL) and extracorporeal shock wave lithotripsy (ESWL) for moderate sized (1-2 cm) upper and middle pole renal calculi in regards to stone clearance rate, morbidity, and quality of life. All patients diagnosed with moderate sized upper and middle pole kidney stones by computed tomography (CT) were offered enrollment. They were randomized to receive either ESWL or PNL. The SF-8 quality of life survey was administered preoperatively and at 1 week and 3 months postoperatively. Abdominal radiograph at 1 week and CT scan at 3 months were used to determine stone-free status. All complications and outcomes were recorded. PNL established a stone-free status of 95% and 85% at 1 week and 3 months, respectively, whereas ESWL established a stone-free status of 17% and 33% at 1 week and 3 months, respectively. Retreatment in ESWL was required in 67% of cases, with 0% retreatment in PNL. Stone location, stone density, and skin-to-stone distance had no impact on stone-free rates at both visits, irrespective of procedure. Patient-reported outcomes, including overall physical and mental health status, favored a better quality of life for patients who had PNL performed. PNL more often establishes stone-free status, has a more similar complication profile, and has similar reported quality of life at 3 months when compared with ESWL for moderate-sized kidney stones. PNL should be offered as a treatment option to all patients with moderate-sized kidney stones in centers with experienced endourologists. Copyright © 2011 Elsevier Inc. All rights reserved.
Two-color fluorescent (near-infrared and visible) triphasic perfluorocarbon nanoemulsions
Patel, Sravan Kumar; Patrick, Michael J.; Pollock, John A.
2013-01-01
Abstract. Design and development of a new formulation as a unique assembly of distinct fluorescent reporters with nonoverlapping fluorescence spectra and a F19 magnetic resonance imaging agent into colloidally and optically stable triphasic nanoemulsion are reported. Specifically, a cyanine dye-perfluorocarbon (PFC) conjugate was introduced into the PFC phase of the nanoemulsion and a near-infrared dye was introduced into the hydrocarbon (HC) layer. To the best of our knowledge, this is the first report of a triphasic nanoemulsion system where each oil phase, HC, and PFC are fluorescently labeled and formulated into an optically and colloidally stable nanosystem. Having, each oil phase separately labeled by a fluorescent dye allows for improved correlation between in vivo imaging and histological data. Further, dual fluorescent labeling can improve intracellular tracking of the nanodroplets and help assess the fate of the nanoemulsion in biologically relevant media. The nanoemulsions were produced by high shear processing (microfluidization) and stabilized with biocompatible nonionic surfactants resulting in mono-modal size distribution with average droplet size less than 200 nm. Nanoemulsions demonstrate excellent colloidal stability and only moderate changes in the fluorescence signal for both dyes. Confocal fluorescence microscopy of macrophages exposed to nanoemulsions shows the presence of both fluorescence agents in the cytoplasm. PMID:23912666
NASA Astrophysics Data System (ADS)
Nicchio, Matheus A.; Nogueira, Francisco C. C.; Balsamo, Fabrizio; Souza, Jorge A. B.; Carvalho, Bruno R. B. M.; Bezerra, Francisco H. R.
2018-02-01
In this work we describe the deformation mechanisms and processes that occurred during the evolution of cataclastic deformation bands developed in the feldspar-rich conglomerates of the Rio do Peixe Basin, NE Brazil. We studied bands with different deformation intensities, ranging from single cm-thick tabular bands to more evolved clustering zones. The chemical identification of cataclastic material within deformation bands was performed using compositional mapping in SEM images, EDX and XRD analyses. Deformation processes were identified by microstructural analysis and by the quantification of comminution intensity, performed using digital image processing. The deformation bands are internally non homogeneous and developed during five evolutionary stages: (1) moderate grain size reduction, grain rotation and grain border comminution; (2) intense grain size reduction with preferential feldspar fragmentation; (3) formation of subparallel C-type slip zones; (4) formation of S-type structures, generating S-C-like fabric; and (5) formation of C‧-type slip zones, generating well-developed foliation that resembles S-C-C‧-type structures in a ductile environment. Such deformation fabric is mostly imparted by the preferential alignment of intensely comminuted feldspar fragments along thin slip zones developed within deformation bands. These processes were purely mechanical (i.e., grain crushing and reorientation). No clays or fluids were involved in such processes.
The Conditioning Influence of Organization Size Upon Managerial Practice
ERIC Educational Resources Information Center
Mahoney, Thomas A.; And Others
1972-01-01
Two dimensions of organization size -- unit size and size of parent organization -- are analyzed for independent and joint relationships with various dimensions of organizational behavior and managerial practice. Results suggest that managerial practices of delegation, staffing, and direction vary with size and moderate expected size influences…
Advances in Satellite Remote Sensing of Particulate Air Pollution: From MISR to MAIA
NASA Astrophysics Data System (ADS)
Diner, D. J.; Burke, K.; Xu, F.; Garay, M. J.; Kalashnikova, O. V.; Liu, Y.; Meng, X.; Wang, J.; Martin, R.; Ostro, B.
2017-12-01
Airborne particulate matter (PM) is a well-known cause of cardiovascular and respiratory disease. To estimate human exposure to PM pollution, satellite instruments such as the Terra Multi-angle Imaging SpectroRadiometer (MISR) and the Moderate resolution Imaging Spectroradiometer (MODIS) have been used in conjunction with surface monitors to map near-surface PM concentrations. The relative toxicity of different size and compositional mixtures of PM is not well understood. To address this, we are developing the Multi-Angle Imager for Aerosols (MAIA) investigation. The satellite instrument extends MISR's multiangular visible and near-infrared (VNIR) spectral coverage to 14 bands in the ultraviolet, VNIR, and shortwave IR; three of the bands are polarimetric to enhance sensitivity to aerosol size and composition. To constrain the retrievals, the observations will be combined with data from surface monitors and the WRF-Chem and GEOS-Chem chemical transport models. Existing surface PM speciation monitors will be supplemented by adding new stations to the Surface PARTiculate mAtter Network (SPARTAN). Unlike MISR, MAIA is a targeting instrument. Primary areas of interest include metropolitan areas in North and South America, Europe, the Middle East, Africa, India, and East Asia. PM retrieval algorithms are being developed using data from MISR and the high-altitude Airborne Multiangle SpectroPolarimetric Imager (AirMSPI). Epidemiologists on the MAIA science team will use the derived PM data products and birth, death, and hospital records to investigate adverse health impacts of different types of airborne particulates. MAIA's earliest possible launch date is mid-2020, making it possible for the data to be complemented by global observations from Terra as well as high temporal resolution atmospheric chemistry measurements from TEMPO (Tropospheric Emissions: Monitoring Pollution), GEMS (Geostationary Environment Monitoring Spectrometer), and Sentinel-4.
Giannini, Daniela; Lombardo, Giuseppe; Mariotti, Letizia; Devaney, Nicholas; Serrao, Sebastiano; Lombardo, Marco
2017-06-01
To assess reliability and agreement among three metrics used to evaluate the distribution of cell distances in adaptive optics (AO) images of the cone mosaic. Using an AO flood illumination retinal camera, we acquired images of the cone mosaic in 20 healthy subjects and 12 patients with retinal diseases. The three spacing metrics studied were the center-to-center spacing (Scc), the local cone spacing (LCS), and the density recovery profile distance (DRPD). Each metric was calculated in sampling areas of different sizes (64 × 64 μm and 204 × 204 μm) across the parafovea. Both Scc and LCS were able to discriminate between healthy subjects and patients with retinal diseases; DRPD did not reliably detect any abnormality in the distribution of cell distances in patients with retinal diseases. The agreement between Scc and LCS was high in healthy subjects (intraclass correlation coefficient [ICC] ≥ 0.79) and moderate in patients with retinal diseases (ICC ≤ 0.51). The DRPD had poor agreement with Scc (ICC ≤ 0.47) and LCS (ICC ≤ 0.37). The correlation between the spacing metrics of the two sampling areas was greater in healthy subjects than in patients with retinal diseases. The Scc and LCS provided interchangeable estimates of cone distance in AO retinal images of healthy subjects but could not be used interchangeably when investigating retinal diseases with significant cell reflectivity loss (≥30%). The DRPD was unreliable for describing cell distance in a human retinal cone mosaic and did not correlate with Scc and LCS. Caution is needed when comparing spacing metrics evaluated in sampling areas of different sizes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maughan, N; Conti, M; Parikh, P
2015-06-15
Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filledmore » with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects of the body matrix coil and off-center measurements.« less
Practical Weak-lensing Shear Measurement with Metacalibration
Sheldon, Erin S.; Huff, Eric M.
2017-05-19
We report that metacalibration is a recently introduced method to accurately measure weak gravitational lensing shear using only the available imaging data, without need for prior information about galaxy properties or calibration from simulations. The method involves distorting the image with a small known shear, and calculating the response of a shear estimator to that applied shear. The method was shown to be accurate in moderate-sized simulations with galaxy images that had relatively high signal-to-noise ratios, and without significant selection effects. In this work we introduce a formalism to correct for both shear response and selection biases. We also observemore » that for images with relatively low signal-to-noise ratios, the correlated noise that arises during the metacalibration process results in significant bias, for which we develop a simple empirical correction. To test this formalism, we created large image simulations based on both parametric models and real galaxy images, including tests with realistic point-spread functions. We varied the point-spread function ellipticity at the five-percent level. In each simulation we applied a small few-percent shear to the galaxy images. We introduced additional challenges that arise in real data, such as detection thresholds, stellar contamination, and missing data. We applied cuts on the measured galaxy properties to induce significant selection effects. Finally, using our formalism, we recovered the input shear with an accuracy better than a part in a thousand in all cases.« less
Multi-Frequency Intravascular Ultrasound (IVUS) Imaging
Ma, Teng; Yu, Mingyue; Chen, Zeyu; Fei, Chunlong; Shung, K. Kirk; Zhou, Qifa
2015-01-01
Acute coronary syndrome (ACS) is frequently associated with the sudden rupture of a vulnerable atherosclerotic plaque within the coronary artery. Several unique physiological features, including a thin fibrous cap accompanied by a necrotic lipid core, are the targeted indicators for identifying the vulnerable plaques. Intravascular ultrasound (IVUS), a catheter-based imaging technology, has been routinely performed in clinics for more than 20 years to describe the morphology of the coronary artery and guide percutaneous coronary interventions. However, conventional IVUS cannot facilitate the risk assessment of ACS because of its intrinsic limitations, such as insufficient resolution. Renovation of the IVUS technology is essentially needed to overcome the limitations and enhance the coronary artery characterization. In this paper, a multi-frequency intravascular ultrasound (IVUS) imaging system was developed by incorporating a higher frequency IVUS transducer (80 to 150 MHz) with the conventional IVUS (30–50 MHz) system. The newly developed system maintains the advantage of deeply penetrating imaging with the conventional IVUS, while offering an improved higher resolution image with IVUS at a higher frequency. The prototyped multi-frequency catheter has a clinically compatible size of 0.95 mm and a favorable capability of automated image co-registration. In vitro human coronary artery imaging has demonstrated the feasibility and superiority of the multi-frequency IVUS imaging system to deliver a more comprehensive visualization of the coronary artery. This ultrasonic-only intravascular imaging technique, based on a moderate refinement of the conventional IVUS system, is not only cost-effective from the perspective of manufacturing and clinical practice, but also holds the promise of future translation into clinical benefits. PMID:25585394
ERIC Educational Resources Information Center
Park, Woochul; Epstein, Norman B.
2013-01-01
This study examined the longitudinal relationship between self-esteem and body image distress, as well as the moderating effect of relationships with parents, among adolescents in Korea, using nationally representative prospective panel data. Regarding causal direction, the findings supported bi-directionality for girls, but for boys the…
Verde, Franco; Hruban, Ralph H; Fishman, Elliot K
Small bowel gastrointestinal stromal tumors (SB-GISTs) are rare lesions with a variable appearance on computed tomography (CT). This case series analyzes the CT enhancement pattern with the histologic risk assessment of tumor progression. Local institutional pathology database was searched for SB-GISTs from 2000 to 2015. Pathology reports and clinical notes were reviewed. Imaging was qualitatively reviewed for pattern of enhancement categorized into homogeneous or heterogeneous groups. Nonparametric statistical analysis was performed comparing enhancement to segment of bowel involved, presence of necrosis, tumor size, histologic grade (ie, G1 or G2), and histologic risk of progression (ie low, moderate, high). For simplicity, risk of progression was binned into low-risk or non-low-risk groups. Twenty-six pathology-proven, first presentation, nonmetastatic SB-GISTs were included into study. Seventeen were located in duodenum, 7 in jejunum, and 2 within the ileum. Dual phase (arterial and venous) CT imaging was available for 22 cases. Four cases did not have dual phase (three venous phase and one arterial phase only). Seventeen cases demonstrated heterogeneous enhancement and 9 cases homogeneous enhancement. Statistically significant difference was found between size versus enhancement groups (3.1 cm for homogeneous versus 6.8 cm for heterogeneous) (Mann-Whitney U test, n = 26, P = 0.002). Presence of necrosis versus enhancement group was statistically significant (Pearson χ, P = 0.001). Low-risk and non-low-risk groups versus enhancement groups was very significant (P = 0.001). Bowel segment involvement and histologic grading versus enhancement group did not reach statistical significance (P = 0.174 and P = 0.07, respectively). This case series reveals an important significant association between heterogeneous enhancement and non-low risk (ie, moderate/high) SB-GISTs. Beyond just describing the tumor, using enhancing pattern, the interpreting radiologist can preoperatively suggest additional prognostic information, potentially helpful for surgical planning.
Shannon Claeson; B. Coffin
2015-01-01
Dam removal is an increasingly practised river restoration technique, and ecological responses vary with watershed, dam and reservoir properties, and removal strategies. Moderate-sized dams, like Hemlock Dam (7.9m tall and 56m wide), are large enough that removal effects could be significant, but small enough that mitigation may be possible through a modified dam...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Callstrom, Matthew R., E-mail: callstrom.matthew@mayo.edu; McKusick, Michael A., E-mail: mckusick.michael@mayo.edu
PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5)more » for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA.« less
Mischner, Isabelle H S; van Schie, Hein T; Wigboldus, Daniël H J; van Baaren, Rick B; Engels, Rutger C M E
2013-01-01
The present study investigated the effect of sexually objectifying music video exposure on young women's implicit bodily self-perception and the moderating role of self-esteem. Fifty-six college women of normal weight were either exposed to three sexually objectifying music videos or three neutral music videos. Perceived and ideal body size were measured both before and after video exposure, using horizontally stretched and compressed photographs of the participant's own body in swimming garment. As expected, only women low (but not high) in self-esteem were negatively affected by the sexually objectifying content of the music videos: they perceived themselves as bigger and showed an increased discrepancy between their perceived and ideal body size after video exposure. The neutral music videos did not influence women's bodily self-perceptions. These findings suggest that body image is a flexible construct, and that high self-esteem can protect women against the adverse effects of sexually objectifying media. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cooke, Richard; French, David P
2008-01-01
Meta-analysis was used to quantify how well the Theories of Reasoned Action and Planned Behaviour have predicted intentions to attend screening programmes and actual attendance behaviour. Systematic literature searches identified 33 studies that were included in the review. Across the studies as a whole, attitudes had a large-sized relationship with intention, while subjective norms and perceived behavioural control (PBC) possessed medium-sized relationships with intention. Intention had a medium-sized relationship with attendance, whereas the PBC-attendance relationship was small sized. Due to heterogeneity in results between studies, moderator analyses were conducted. The moderator variables were (a) type of screening test, (b) location of recruitment, (c) screening cost and (d) invitation to screen. All moderators affected theory of planned behaviour relationships. Suggestions for future research emerging from these results include targeting attitudes to promote intention to screen, a greater use of implementation intentions in screening information and examining the credibility of different screening providers.
Disentangling reward anticipation with simultaneous pupillometry / fMRI.
Schneider, Max; Leuchs, Laura; Czisch, Michael; Sämann, Philipp G; Spoormaker, Victor I
2018-05-05
The reward system may provide an interesting intermediate phenotype for anhedonia in affective disorders. Reward anticipation is characterized by an increase in arousal, and previous studies have linked the anterior cingulate cortex (ACC) to arousal responses such as dilation of the pupil. Here, we examined pupil dynamics during a reward anticipation task in forty-six healthy human subjects and evaluated its neural correlates using functional magnetic resonance imaging (fMRI). Pupil size showed a strong increase during monetary reward anticipation, a moderate increase during verbal reward anticipation and a decrease during control trials. For fMRI analyses, average pupil size and pupil change were computed in 1-s time bins during the anticipation phase. Activity in the ventral striatum was inversely related to the pupil size time course, indicating an early onset of activation and a role in reward prediction processing. Pupil dilations were linked to increased activity in the salience network (dorsal ACC and bilateral insula), which likely triggers an increase in arousal to enhance task performance. Finally, increased pupil size preceding the required motor response was associated with activity in the ventral attention network. In sum, pupillometry provides an effective tool for disentangling different phases of reward anticipation, with relevance for affective symptomatology. Copyright © 2018 Elsevier Inc. All rights reserved.
Yang, Jung Dug; Bae, Sung Gun; Chung, Ho Yun; Cho, Byung Chae; Park, Ho Yong; Jung, Jin Hyang
2011-11-01
Because the average breast size of Korean women is not as large as that of western women, it is not so easy to apply the oncoplastic volume displacement technique. However, we have tried to use volume displacement techniques that work well with small-breasted women. In this study, we report the usefulness of displacement techniques in the superiorly located cancers with small- to moderate-sized breasts. Between September 2006 and August 2009, 58 women were treated for superiorly located cancers. All patients who were selected had small- to moderate-sized breasts and small to moderate breast defects. They were divided into 3 groups. The groups were split based on the distance from the nipple-areolar complex, which are as follows: near, intermediate, and far. Their mean age was 46 and the average follow-up interval was 21 months. Median weight of the specimen on the tumor side was 84 g (range, 29-140 g). The various surgical techniques used were the "round block" technique (n = 8) and "batwing mastopexy" (n = 4) for near lesions; "tennis racket" method (n = 32) and "rotational flap" (n = 8) for intermediate lesions; and "parallelogram mastopexy lumpectomy" (n = 6) for far lesions. There were 4 complications (nipple-areolar complex partial necrosis, radiation burn, and 2 wound dehiscence). No local recurrences have been observed and a majority of the patients were satisfied with cosmetic results. Oncoplastic volume displacement techniques in superiorly located breast cancers for Korean patients with small- to moderate-sized breast are reliable and should be considered in the case of breast conserving surgery (BCS).
The Dynamics of Agglomerated Ferrofluid in Steady and Pulsatile Flows
NASA Astrophysics Data System (ADS)
Williams, Alicia; Stewart, Kelley; Vlachos, Pavlos
2007-11-01
Magnetic Drug Targeting (MDT) is a promising technique to deliver medication via functionalized magnetic particles to target sites in the treatment of diseases. In this work, the physics of steady and pulsatile flows laden with superparamagnetic nanoparticles in a square channel under the influence of a magnetic field induced by a 0.6 Tesla permanent magnet is studied. Herein, the dynamics of ferrofluid shedding from an initially accumulated mass in water are examined through shadowgraph imaging using two orthogonal cameras. Fundamental differences in the ferrofluid behavior occur between the steady and pulsatile flow cases, as expected. For steady flows, vortex ring shedding is visualized from the mass, and periodic shedding occurs only for moderate mass sizes where the shear forces in the flow interact with the magnetic forces. At Reynolds numbers below 500 with pulsatile flow, suction and roll up of the ferrofluid is seen during the low and moderate periods of flow, followed by the ejection of ferrofluid during high flow. These shadowgraphs illustrate the beauty and richness of ferrofluid dynamics, an understanding of which is instrumental to furthering MDT as an effective drug delivery device.
A programmable CCD driver circuit for multiphase CCD operation
NASA Technical Reports Server (NTRS)
Ewin, Audrey J.; Reed, Kenneth V.
1989-01-01
A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.
Lung ventilation studies with technetium-99m Pseudogas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burch, W.M.; Sullivan, P.J.; Lomas, F.E.
1986-06-01
Technetium-99m Pseudogas is an ultrafine near monodisperse aerosol of 0.12-microgram diam particle size. This report describes initial clinical experiences with 27 patients referred for investigation of suspected pulmonary embolism, and in whom Pseudogas ventilation images were compared with a high quality commercial aerosol. An additional group of ten patients with severe COPD was examined in a comparative trial of Pseudogas with 81mKr. Pseudogas was better than a conventional aerosol in reaching a diagnosis of pulmonary embolism using a simple blinded comparison with coded images. In addition, bronchial deposition was minimal unless COPD was severe. Moderately well patients had no difficultymore » inhaling the necessary activity in one or two breaths, and even severely ill and frail aged persons could accomplish the passive breathing maneuver in less than a minute. Clearance of Pseudogas was directly to the systemic circulation with a half-time of 10 min in normal subjects extending up to 100 min in patients with airways disease.« less
A high-resolution X-ray image of Puppis A - Inhomogeneities in the interstellar medium
NASA Technical Reports Server (NTRS)
Petre, R.; Kriss, G. A.; Winkler, P. F.; Canizares, C. R.
1982-01-01
Eleven HRI exposures from the Einstein Observatory are assembled into an 0.1-4 keV image of the Puppis A supernova remnant which displays a complex morphology that may reflect the structure of the shocked interstellar medium. In addition to showing a density gradient of a factor greater than four across the approximately 30 pc diameter of the remnant perpendicular to the galactic plane, a shell of X-ray emission is seen surrounding the northern half of Puppis A, coincident with the radio shell, whose edge brightness profile indicates direct hot plasma heating by the blast wave rather than evaporation from clouds. The interior structure of the supernova remnant suggests inhomogeneities whose sizes range over 0.1-5 pc, but with moderate density contrast. Although isolated clouds of 10-30/cu cm density are responsible for the two brightest X-ray features, they represent only a small fraction of the Puppis A mass.
Learning target masks in infrared linescan imagery
NASA Astrophysics Data System (ADS)
Fechner, Thomas; Rockinger, Oliver; Vogler, Axel; Knappe, Peter
1997-04-01
In this paper we propose a neural network based method for the automatic detection of ground targets in airborne infrared linescan imagery. Instead of using a dedicated feature extraction stage followed by a classification procedure, we propose the following three step scheme: In the first step of the recognition process, the input image is decomposed into its pyramid representation, thus obtaining a multiresolution signal representation. At the lowest three levels of the Laplacian pyramid a neural network filter of moderate size is trained to indicate the target location. The last step consists of a fusion process of the several neural network filters to obtain the final result. To perform this fusion we use a belief network to combine the various filter outputs in a statistical meaningful way. In addition, the belief network allows the integration of further knowledge about the image domain. By applying this multiresolution recognition scheme, we obtain a nearly scale- and rotational invariant target recognition with a significantly decreased false alarm rate compared with a single resolution target recognition scheme.
NASA Technical Reports Server (NTRS)
King, Michael D.; Menzel, W. Paul; Kaufman, Yoram J.; Tanre, Didier; Gao, Bo-Cai; Platnick, Steven; Ackerman, Steven A.; Remer, Lorraine A.; Pincus, Robert; Hubanks, Paul A.
2003-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) is an earth-viewing sensor that flies on the Earth Observing System (EOS) Terra and Aqua satellites, launched in 1999 and 2002, respectively. MODIS scans a swath width of 2330 km that is sufficiently wide to provide nearly complete global coverage every two days from a polar-orbiting, sun-synchronous, platform at an altitude of 705 km. MODIS provides images in 36 spectral bands between 0.415 and 14.235 pm with spatial resolutions of 250 m (2 bands), 500 m (5 bands) and 1000 m (29 bands). These bands have been carefully selected to en- able advanced studies of land, ocean, and atmospheric properties. Twenty-six bands are used to derive atmospheric properties such as cloud mask, atmospheric profiles, aerosol properties, total precipitable water, and cloud properties. In this paper we describe each of these atmospheric data products, including characteristics of each of these products such as file size, spatial resolution used in producing the product, and data availability.
The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data
Hsiao, Yu-Yu; Lai, Mark H. C.
2018-01-01
Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended. PMID:29867692
The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data.
Hsiao, Yu-Yu; Lai, Mark H C
2018-01-01
Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended.
Olatunji, Bunmi O; Kauffman, Brooke Y; Meltzer, Sari; Davis, Michelle L; Smits, Jasper A J; Powers, Mark B
2014-07-01
The present investigation employed meta-analysis to examine the efficacy of cognitive-behavioral therapy (CBT) for hypochondriasis/health anxiety as well as potential moderators that may be associated with outcome. A literature search revealed 15 comparisons among 13 randomized-controlled trials (RCTs) with a total sample size of 1081 participants that met inclusion criteria. Results indicated that CBT outperformed control conditions on primary outcome measures at post-treatment (Hedges's g = 0.95) and at follow-up (Hedges's g = 0.34). CBT also outperformed control conditions on measures of depression at post-treatment (Hedges's g = 0.64) and at follow-up (Hedges's g = 0.35). Moderator analyses revealed that higher pre-treatment severity of hypochondriasis/health anxiety was associated with greater effect sizes at follow-up visits and depression symptom severity was significantly associated with a lower in effect sizes at post-treatment. Although effect size did not vary as a function of blind assessment, smaller effect sizes were observed for CBT vs. treatment as usual control conditions than for CBT vs. waitlist control. A dose response relationship was also observed, such that a greater number of CBT sessions was associated with larger effect sizes at post-treatment. This review indicates that CBT is efficacious in the treatment of hypochondriasis/health anxiety and identifies potential moderators that are associated with outcome. The implications of these findings for further delineating prognostic and prescriptive indicators of CBT for hypochondriasis/health anxiety are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Comparison of CERES Cloud Properties Derived from Aqua and Terra MODIS Data and TRMM VIRS Radiances
NASA Astrophysics Data System (ADS)
Minnis, P.; Young, D. F.; Sun-Mack, S.; Trepte, Q. Z.; Chen, Y.; Heck, P. W.; Wielicki, B. A.
2003-12-01
The Clouds and Earth's Radiant Energy System (CERES) Project is obtaining Earth radiation budget measurements of unprecedented accuracy as a result of improved instruments and an analysis system that combines simultaneous, high-resolution cloud property retrievals with the broadband radiance data. The cloud properties are derived from three different satellite imagers: the Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission (TRMM) and the Moderate Resolution Imaging Spectroradiometers (MODIS) on the Aqua and Terra satellites. A single set of consistent algorithms using the 0.65, 1.6 or 2.1, 3.7, 10.8, and 12.0-æm channels are applied to all three imagers. The cloud properties include, cloud coverage, height, thickness, temperature, optical depth, phase, effective particle size, and liquid or ice water path. Because each satellite is in a different orbit, the results provide information on the diurnal cycle of cloud properties. Initial intercalibrations show excellent consistency between the three images except for some differences of ~ 1K between the 3.7-æm channel on Terra and those on VIRS and Aqua. The derived cloud properties are consistent with the known diurnal characteristics of clouds in different areas. These datasets should be valuable for exploring the role of clouds in the radiation budget and hydrological cycle.
MODIS: Moderate-resolution imaging spectrometer. Earth observing system, volume 2B
NASA Technical Reports Server (NTRS)
1986-01-01
The Moderate-Resolution Imaging Spectrometer (MODIS), as presently conceived, is a system of two imaging spectroradiometer components designed for the widest possible applicability to research tasks that require long-term (5 to 10 years), low-resolution (52 channels between 0.4 and 12.0 micrometers) data sets. The system described is preliminary and subject to scientific and technological review and modification, and it is anticipated that both will occur prior to selection of a final system configuration; however, the basic concept outlined is likely to remain unchanged.
Pritchett, Yili; Jemiai, Yannis; Chang, Yuchiao; Bhan, Ishir; Agarwal, Rajiv; Zoccali, Carmine; Wanner, Christoph; Lloyd-Jones, Donald; Cannata-Andía, Jorge B; Thompson, Taylor; Appelbaum, Evan; Audhya, Paul; Andress, Dennis; Zhang, Wuyan; Solomon, Scott; Manning, Warren J; Thadhani, Ravi
2011-04-01
Chronic kidney disease is associated with a marked increase in risk for left ventricular hypertrophy and cardiovascular mortality compared with the general population. Therapy with vitamin D receptor activators has been linked with reduced mortality in chronic kidney disease and an improvement in left ventricular hypertrophy in animal studies. PRIMO (Paricalcitol capsules benefits in Renal failure Induced cardia MOrbidity) is a multinational, multicenter randomized controlled trial to assess the effects of paricalcitol (a selective vitamin D receptor activator) on mild to moderate left ventricular hypertrophy in patients with chronic kidney disease. Subjects with mild-moderate chronic kidney disease are randomized to paricalcitol or placebo after confirming left ventricular hypertrophy using a cardiac echocardiogram. Cardiac magnetic resonance imaging is then used to assess left ventricular mass index at baseline, 24 and 48 weeks, which is the primary efficacy endpoint of the study. Because of limited prior data to estimate sample size, a maximum information group sequential design with sample size re-estimation is implemented to allow sample size adjustment based on the nuisance parameter estimated using the interim data. An interim efficacy analysis is planned at a pre-specified time point conditioned on the status of enrollment. The decision to increase sample size depends on the observed treatment effect. A repeated measures analysis model, using available data at Week 24 and 48 with a backup model of an ANCOVA analyzing change from baseline to the final nonmissing observation, are pre-specified to evaluate the treatment effect. Gamma-family of spending function is employed to control family-wise Type I error rate as stopping for success is planned in the interim efficacy analysis. If enrollment is slower than anticipated, the smaller sample size used in the interim efficacy analysis and the greater percent of missing week 48 data might decrease the parameter estimation accuracy, either for the nuisance parameter or for the treatment effect, which might in turn affect the interim decision-making. The application of combining a group sequential design with a sample-size re-estimation in clinical trial design has the potential to improve efficiency and to increase the probability of trial success while ensuring integrity of the study.
ERIC Educational Resources Information Center
Liu, Duo; Li, Hong; Wong, Kwok Shing Richard
2017-01-01
In the present study, the mediating roles of syllable awareness, orthographic knowledge, and vocabulary skills and the moderating role of morpheme family size in the association between morphological awareness and Chinese character reading were investigated with 176 second-grade Hong Kong Chinese children. In the path analyses, the results…
NASA Astrophysics Data System (ADS)
Brenton, J. C.; Keeton, T.; Barrick, B.; Cowart, K.; Cooksey, K.; Florence, V.; Herdy, C.; Luvall, J. C.; Vasquez, S.
2012-12-01
Exposure to high concentrations of airborne particulate matter can have adverse effects on the human respiratory system. Ground-based studies conducted in Iraq have revealed the presence of potential human pathogens in airborne dust. According to the Environmental Protection Agency (EPA), airborne particulate matter below 2.5μm (PM2.5) can cause long-term damage to the human respiratory system. Given the relatively high incidence of new-onset respiratory disorders experienced by US service members deployed to Iraq, this research offers a new glimpse into how satellite remote sensing can be applied to questions related to human health. NASA's Earth Observing System (EOS) can be used to determine spectral characteristics of dust particles, the depth of dust plumes, as well as dust particle sizes. Comparing dust particle size from the Sahara and Arabian Deserts gives insight into the composition and atmospheric transport characteristics of dust from each desert. With the use of NASA SeaWiFS DeepBlue Aerosol, dust particle sizes were estimated using Angström exponent. Brightness Temperature Difference (BTD) equation was used to determine the distribution of particle sizes, the area of the dust storm, and whether silicate minerals were present in the dust. The Moderate-resolution Imaging Spectroradiometer (MODIS) on Terra satellite was utilized in calculating BTD. Minimal research has been conducted on the spectral characteristics of airborne dust in the Arabian and Sahara Deserts. Mineral composition of a dust storm that occurred 17 April 2008 near Baghdad was determined using imaging spectrometer data from the Jet Propulsion Laboratory Spectral Library and EO-1 Hyperion data. Mineralogy of this dust storm was subsequently compared to that of a dust storm that occurred over the Bodélé Depression in the Sahara Desert on 7 June 2003.
Does group size have an impact on welfare indicators in fattening pigs?
Meyer-Hamme, S E K; Lambertz, C; Gauly, M
2016-01-01
Production systems for fattening pigs have been characterized over the last 2 decades by rising farm sizes coupled with increasing group sizes. These developments resulted in a serious public discussion regarding animal welfare and health in these intensive production systems. Even though large farm and group sizes came under severe criticism, it is still unknown whether these factors indeed negatively affect animal welfare. Therefore, the aim of this study was to assess the effect of group size (30 pigs/pen) on various animal-based measures of the Welfare Quality(®) protocol for growing pigs under conventional fattening conditions. A total of 60 conventional pig fattening farms with different group sizes in Germany were included. Moderate bursitis (35%) was found as the most prevalent indicator of welfare-related problems, while its prevalence increased with age during the fattening period. However, differences between group sizes were not detected (P>0.05). The prevalence of moderately soiled bodies increased from 9.7% at the start to 14.2% at the end of the fattening period, whereas large pens showed a higher prevalence (15.8%) than small pens (10.4%; P<0.05). With increasing group size, the incidence of moderate wounds with 8.5% and 11.3% in small- and medium-sized pens, respectively, was lower (P<0.05) than in large-sized ones (16.3%). Contrary to bursitis and dirtiness, its prevalence decreased during the fattening period. Moderate manure was less often found in pigs fed by a dry feeder than in those fed by a liquid feeding system (P<0.05). The human-animal relationship was improved in large in comparison to small groups. On the contrary, negative social behaviour was found more often in large groups. Exploration of enrichment material decreased with increasing live weight. Given that all animals were tail-docked, tail biting was observed at a very low rate of 1.9%. In conclusion, the results indicate that BW and feeding system are determining factors for the welfare status, while group size was not proved to affect the welfare level under the studied conditions of pig fattening.
Litt, Dana M.; Stock, Michelle L.; Gibbons, Frederick X.
2014-01-01
Objectives Research has indicated that both peers and siblings influence adolescents' alcohol use (e.g. Windle, 2000). The present two studies examined if social comparison orientation (SCO) moderates the effects of perceived friend and sibling alcohol use on adolescents' alcohol use cognitions and behaviors. Design & Methods Two studies examined the role of SCO as a moderator of social influence (perceived friend alcohol use in Study 1 and both perceived friend use and sibling-reported alcohol use in Study 2) on prototype perceptions and willingness to drink alcohol (Studies 1 & 2) as well as actual alcohol consumption (Study 2) among early adolescents. Results In Study 1, cross-sectional results indicated that SCO moderated the effect of perceived friend alcohol use on favorable images of drinkers and willingness to drink. Study 2 found that SCO moderated the effects of perceived friend use and sibling use on favorable images of alcohol users, willingness to use alcohol, and change in alcohol use over three years such that adolescents who reported engaging in social comparison more often reported greater willingness, more favorable images, and increases in alcohol use when perceived friend use or sibling use was high. Conclusions These studies highlight the importance of SCO as a moderator of susceptibility to the social influences of friends and siblings and may hold important implications for adolescent alcohol use prevention programs and models of health-risk behavior. PMID:25243814
Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S
2017-11-01
Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.
NASA Astrophysics Data System (ADS)
Hou, Gary Y.; Luo, Jianwen; Maleke, Caroline; Vappou, Jonathan; Marquet, Fabrice; Konofagou, Elisa E.
2012-10-01
Harmonic Motion Imaging for Focused Ultrasound (HMIFU) is a novel high-intensity focused ultrasound (HIFU) therapy monitoring method with feasibilities demonstrated in vitro, ex vivo and in vivo. Its principle is based on Amplitude-modulated (AM) - Harmonic Motion Imaging (HMI), an oscillatory radiation force used for imaging the tissue mechanical response during thermal ablation. In this study, a theoretical framework of HMIFU is presented, comprising a customized nonlinear wave propagation model, a finite-element (FE) analysis module, and an image-formation model. The objective of this study is to develop such a framework in order to 1) assess the fundamental performance of HMIFU in detecting HIFU lesions based on the change in tissue apparent elasticity, i.e., the increasing Young's modulus, and the HIFU lesion size with respect to the HIFU exposure time and 2) validate the simulation findings ex vivo. The same HMI and HMIFU parameters as in the experimental studies were used, i.e., 4.5-MHz HIFU frequency and 25-Hz AM frequency. For a lesion-to-background Young's modulus ratio of 3, 6, and 9, the estimated HMI displacement ratios were equal to 1.65, 3.19, 4.59, respectively. In experiments, the HMI displacement followed a similar increasing trend of 1.19, 1.28, 1.78 at 10-s, 20-s, and 30-s HIFU exposure, respectively. In addition, moderate agreement in lesion size growth was also found in both simulations (16.2, 73.1 and 334.7 mm2) and experiments (26.2, 94.2 and 206.2 mm2). Therefore, the feasibility of HMIFU for HIFU lesion detection based on the underlying tissue elasticity changes was verified through the developed theoretical framework, i.e., validation of the fundamental performance of the HMIFU system for lesion detection, localization and quantification, was demonstrated both theoretically and ex vivo.
Hou, Gary Y.; Luo, Jianwen; Marquet, Fabrice; Maleke, Caroline; Vappou, Jonathan; Konofagou, Elisa E.
2014-01-01
Harmonic Motion Imaging for Focused Ultrasound (HMIFU) is a novel high-intensity focused ultrasound (HIFU) therapy monitoring method with feasibilities demonstrated in vitro, ex vivo and in vivo. Its principle is based on Amplitude-modulated (AM) - Harmonic Motion Imaging (HMI), an oscillatory radiation force used for imaging the tissue mechanical response during thermal ablation. In this study, a theoretical framework of HMIFU is presented, comprising a customized nonlinear wave propagation model, a finite-element (FE) analysis module, and an image-formation model. The objective of this study is to develop such a framework in order to 1) assess the fundamental performance of HMIFU in detecting HIFU lesions based on the change in tissue apparent elasticity, i.e., the increasing Young's modulus, and the HIFU lesion size with respect to the HIFU exposure time and 2) validate the simulation findings ex vivo. The same HMI and HMIFU parameters as in the experimental studies were used, i.e., 4.5-MHz HIFU frequency and 25 Hz AM frequency. For a lesion-to-background Young's modulus ratio of 3, 6, and 9, the FE and estimated HMI displacement ratios were equal to 1.83, 3.69, 5.39 and 1.65, 3.19, 4.59, respectively. In experiments, the HMI displacement followed a similar increasing trend of 1.19, 1.28, and 1.78 at 10-s, 20-s, and 30-s HIFU exposure, respectively. In addition, moderate agreement in lesion size growth was also found in both simulations (16.2, 73.1 and 334.7 mm2) and experiments (26.2, 94.2 and 206.2 mm2). Therefore, the feasibility of HMIFU for HIFU lesion detection based on the underlying tissue elasticity changes was verified through the developed theoretical framework, i.e., validation of the fundamental performance of the HMIFU system for lesion detection, localization and quantification, was demonstrated both theoretically and ex vivo. PMID:22036637
Bassett, R L; Martin Ginis, K A
2009-03-01
Cross-sectional. To examine the relationship between body image and leisure time physical activity (LTPA) among men with spinal cord injury (SCI). Specifically, to examine the moderating function of the perceived impact of body image on quality of life (QOL). Ontario, Canada. Men with SCI (N=50, 50% paraplegic) reported, (a) their functional and appearance body image (Adult Body Satisfaction Questionnaire), (b) their perceived impact of body image on QOL and (c) LTPA performed over the previous 3 days. Body image was in the 'normal' range compared with the general population. Linear regression analysis found a significant LTPA x body image impact on QOL interaction beta=0.39, P<0.05. Post hoc analysis showed that among individuals who reported a negative effect of body image on QOL, those who engaged in LTPA were less satisfied with their physical function than those who did not. For those who did not perceive their body image to negatively impact their QOL, there was generally no difference in functional body image between those who engaged in LTPA and those who did not. Appearance body image is not related to LTPA for men with SCI. It has been suggested that body dissatisfaction may motivate some individuals to engage in LTPA. However, for men living with SCI, functional body image may be associated with LTPA only when a negative effect on QOL is perceived. Future research should consider the moderating function of the perceived impact of body image on QOL when examining the relationship between LTPA and body image among men living with SCI.
Results and Validation of MODIS Aerosol Retrievals Over Land and Ocean
NASA Technical Reports Server (NTRS)
Remer, Lorraine; Einaudi, Franco (Technical Monitor)
2001-01-01
The MODerate Resolution Imaging Spectroradiometer (MODIS) instrument aboard the Terra spacecraft has been retrieving aerosol parameters since late February 2000. Initial qualitative checking of the products showed very promising results including matching of land and ocean retrievals at coastlines. Using AERONET ground-based radiometers as our primary validation tool, we have established quantitative validation as well. Our results show that for most aerosol types, the MODIS products fall within the pre-launch estimated uncertainties. Surface reflectance and aerosol model assumptions appear to be sufficiently accurate for the optical thickness retrieval. Dust provides a possible exception, which may be due to non-spherical effects. Over ocean the MODIS products include information on particle size, and these parameters are also validated with AERONET retrievals.
Results and Validation of MODIS Aerosol Retrievals over Land and Ocean
NASA Technical Reports Server (NTRS)
Remer, L. A.; Kaufman, Y. J.; Tanre, D.; Ichoku, C.; Chu, D. A.; Mattoo, S.; Levy, R.; Martins, J. V.; Li, R.-R.; Einaudi, Franco (Technical Monitor)
2000-01-01
The MODerate Resolution Imaging Spectroradiometer (MODIS) instrument aboard the Terra spacecraft has been retrieving aerosol parameters since late February 2000. Initial qualitative checking of the products showed very promising results including matching of land and ocean retrievals at coastlines. Using AERONET ground-based radiometers as our primary validation tool, we have established quantitative validation as well. Our results show that for most aerosol types, the MODIS products fall within the pre-launch estimated uncertainties. Surface reflectance and aerosol model assumptions appear to be sufficiently accurate for the optical thickness retrieval. Dust provides a possible exception, which may be due to non-spherical effects. Over ocean the MODIS products include information on particle size, and these parameters are also validated with AERONET retrievals.
Satellite remote sensing of dust aerosol indirect effects on ice cloud formation.
Ou, Steve Szu-Cheng; Liou, Kuo-Nan; Wang, Xingjuan; Hansell, Richard; Lefevre, Randy; Cocks, Stephen
2009-01-20
We undertook a new approach to investigate the aerosol indirect effect of the first kind on ice cloud formation by using available data products from the Moderate-Resolution Imaging Spectrometer (MODIS) and obtained physical understanding about the interaction between aerosols and ice clouds. Our analysis focused on the examination of the variability in the correlation between ice cloud parameters (optical depth, effective particle size, cloud water path, and cloud particle number concentration) and aerosol optical depth and number concentration that were inferred from available satellite cloud and aerosol data products. Correlation results for a number of selected scenes containing dust and ice clouds are presented, and dust aerosol indirect effects on ice clouds are directly demonstrated from satellite observations.
Ye, Peng; Vander Wal, Randy; Boehman, Andre L.; ...
2014-12-26
The effect of rail pressure and biodiesel fueling on the morphology of exhaust particulate agglomerates and the nanostructure of primary particles (soot) was investigated with a common-rail turbocharged direct injection diesel engine. The engine was operated at steady state on a dynamometer running at moderate speed with both low (30%) and medium–high (60%) fixed loads, and exhaust particulate was sampled for analysis. Ultra-low sulfur diesel and its 20% v/v blends with soybean methyl ester biodiesel were used. Fuel injection occurred in a single event around top dead center at three different injection pressures. Exhaust particulate samples were characterized with TEMmore » imaging, scanning mobility particle sizing, thermogravimetric analysis, Raman spectroscopy, and XRD analysis. Particulate morphology and oxidative reactivity were found to vary significantly with rail pressure and with biodiesel blend level. Higher biodiesel content led to increases in the primary particle size and oxidative reactivity but did not affect nanoscale disorder in the as-received samples. For particulates generated with higher injection pressures, the initial oxidative reactivity increased, but there was no detectable correlation with primary particle size or nanoscale disorder.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Peng; Vander Wal, Randy; Boehman, Andre L.
The effect of rail pressure and biodiesel fueling on the morphology of exhaust particulate agglomerates and the nanostructure of primary particles (soot) was investigated with a common-rail turbocharged direct injection diesel engine. The engine was operated at steady state on a dynamometer running at moderate speed with both low (30%) and medium–high (60%) fixed loads, and exhaust particulate was sampled for analysis. Ultra-low sulfur diesel and its 20% v/v blends with soybean methyl ester biodiesel were used. Fuel injection occurred in a single event around top dead center at three different injection pressures. Exhaust particulate samples were characterized with TEMmore » imaging, scanning mobility particle sizing, thermogravimetric analysis, Raman spectroscopy, and XRD analysis. Particulate morphology and oxidative reactivity were found to vary significantly with rail pressure and with biodiesel blend level. Higher biodiesel content led to increases in the primary particle size and oxidative reactivity but did not affect nanoscale disorder in the as-received samples. For particulates generated with higher injection pressures, the initial oxidative reactivity increased, but there was no detectable correlation with primary particle size or nanoscale disorder.« less
Evaluation of the MODIS Retrievals of Dust Aerosol over the Ocean during PRIDE
NASA Technical Reports Server (NTRS)
Levy, Robert C.; Remer, Lorraine A.; Tanre, Didier; Kaufman, Yoram J.; Ichoku, Charles; Holben, Brent N.; Livingston, John M.; Russell, Philip B.; Maring, Hal
2002-01-01
The Puerto Rico Dust Experiment (PRIDE) took place in Roosevelt Roads, Puerto Rico from June 26 to July 24,2000 to study the radiative and physical properties of African dust aerosol transported into the region. PRIDE had the unique distinction of being the first major field experiment to allow direct comparison of aerosol retrievals from the MODerate Imaging Spectro-radiometer (MODIS) with sunphotometer and in-situ aerosol measurements. Over the ocean, the MODIS algorithm retrieves aerosol optical depth (AOD) as well as information about the aerosols size distribution. During PRIDE, MODIS derived AODs in the red wavelengths (0.66 micrometers) compare closely with AODs measured from sunphotometers, but, are too large at blue and green wavelengths (0.47 and 0.55 micrometers) and too small in the infrared (0.87 micrometers). This discrepancy of spectral slope results in particle size distributions retrieved by MODIS that are small compared to in-situ measurements, and smaller still when compared to sunphotometer sky radiance inversions. The differences in size distributions are, at least in part, associated with MODIS simplification of dust as spherical particles. Analysis of this PRIDE data set is a first step towards derivation of realistic non-spherical models for future MODIS retrievals.
Ward, Phil; Counsell, Serena; Allsop, Joanna; Cowan, Frances; Shen, Yuji; Edwards, David; Rutherford, Mary
2006-04-01
Apparent diffusion coefficients (ADC) that are measured by diffusion-weighted imaging are reduced in severe white matter (WM) and in some severe basal ganglia and thalamic (BGT) injury in infants who present with hypoxic-ischemic encephalopathy (HIE). However, ADC values may pseudonormalize or even be high during this time in some less severe but clinically significant injuries. We hypothesized that fractional anisotropy (FA), a measure of the directional diffusivity of water made using diffusion tensor imaging, may be abnormal in these less severe injuries; therefore, the objective of this study was to use diffusion tensor imaging to measure ADC and FA in infants with moderate and severe hypoxic-ischemic brain injury. Twenty infants with HIE and 7 normal control infants were studied. All infants were born at >36 weeks' gestational age, and MRI scans were obtained within 3 weeks of delivery. Data were examined for normality, and comparisons were made using analysis of variance or Kruskal-Wallis as appropriate. During the first week, FA values were decreased with both severe and moderate WM and BGT injury as assessed by conventional imaging, whereas ADC values were reduced only in severe WM injury and some severe BGT injury. Abnormal ADC values pseudonormalized during the second week, whereas FA values continued to decrease. FA is reduced in moderate brain injury after HIE. A low FA may reflect a breakdown in WM organization. Moderate BGT injury may result in atrophy but not overt infarction; it is possible that delayed apoptosis is more marked than immediate necrosis, and this may account for normal early ADC values. The accompanying low FA within some severe and all moderate gray matter lesions, which is associated with significant later impairment, may help to confirm clinically significant abnormality in infants with normal ADC values.
Shellock, Frank G; Audet-Griffin, Annabelle J
2014-06-01
The objective of this investigation was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, MRI-related heating, and artifacts) for a wirelessly powered lead used for spinal cord stimulation (SCS). A newly developed, wirelessly powered lead (Freedom-4, Stimwave Technologies Inc., Scottsdale, AZ, USA) underwent evaluation for magnetic field interactions (translational attraction and torque) at 3 Tesla, MRI-related heating at 1.5 Tesla/64 MHz and 3 Tesla/128 MHz, and artifacts at 3 Tesla using standardized techniques. MRI-related heating tests were conducted by placing the lead in a gelled-saline-filled phantom and performing MRI procedures using relatively high levels of radiofrequency energy. Artifacts were characterized using T1-weighted, spin echo (SE), and gradient echo (GRE) pulse sequences. The lead exhibited minor magnetic field interactions (2 degree deflection angle and no torque). Heating was not substantial under 1.5 Tesla/64 MHz (highest temperature change, 2.3°C) and 3 Tesla/128 MHz (highest temperature change, 2.2°C) MRI conditions. Artifacts were moderate in size relative to the size and shape of the lead. These findings demonstrated that it is acceptable for a patient with this wirelessly powered lead used for SCS to undergo MRI under the conditions utilized in this investigation and according to other necessary guidelines. Artifacts seen on magnetic resonance images may pose possible problems if the area of interest is in the same area or close to this lead. © 2013 International Neuromodulation Society.
Reid, Lee B; Pagnozzi, Alex M; Fiori, Simona; Boyd, Roslyn N; Dowson, Nicholas; Rose, Stephen E
2017-05-01
Researchers in the field of child neurology are increasingly looking to supplement clinical trials of motor rehabilitation with neuroimaging in order to better understand the relationship between behavioural training, brain changes, and clinical improvements. Randomised controlled trials are typically accompanied by sample size calculations to detect clinical improvements but, despite the large cost of neuroimaging, not equivalent calculations for concurrently acquired imaging neuroimaging measures of changes in response to intervention. To aid in this regard, a power analysis was conducted for two measures of brain changes that may be indexed in a trial of rehabilitative therapy for cerebral palsy: cortical thickness of the impaired primary sensorimotor cortex, and fractional anisotropy of the impaired, delineated corticospinal tract. Power for measuring fractional anisotropy was assessed for both region-of-interest-seeded and fMRI-seeded diffusion tractography. Taking into account practical limitations, as well as data loss due to behavioural and image-processing issues, estimated required participant numbers were 101, 128 and 59 for cortical thickness, region-of-interest-based tractography, and fMRI-seeded tractography, respectively. These numbers are not adjusted for study attrition. Although these participant numbers may be out of reach of many trials, several options are available to improve statistical power, including careful preparation of participants for scanning using mock simulators, careful consideration of image processing options, and enrolment of as homogeneous a cohort as possible. This work suggests that smaller and moderate sized studies give genuine consideration to harmonising scanning protocols between groups to allow the pooling of data. Copyright © 2017 ISDN. All rights reserved.
Kerkhof, M; Hagenbeek, R E; van der Kallen, B F W; Lycklama À Nijeholt, G J; Dirven, L; Taphoorn, M J B; Vos, M J
2016-10-01
Conventional magnetic resonance imaging (MRI) has limited value for differentiation of true tumor progression and pseudoprogression in treated glioblastoma multiforme (GBM). Perfusion weighted imaging (PWI) may be helpful in the differentiation of these two phenomena. Here interobserver variability in routine radiological evaluation of GBM patients is assessed using MRI, including PWI. Three experienced neuroradiologists evaluated MR scans of 28 GBM patients during temozolomide chemoradiotherapy at three time points: preoperative (MR1) and postoperative (MR2) MR scan and the follow-up MR scan after three cycles of adjuvant temozolomide (MR3). Tumor size was measured both on T1 post-contrast and T2 weighted images according to the Response Assessment in Neuro-Oncology criteria. PW images of MR3 were evaluated by visual inspection of relative cerebral blood volume (rCBV) color maps and by quantitative rCBV measurements of enhancing areas with highest rCBV. Image interpretability of PW images was also scored. Finally, the neuroradiologists gave a conclusion on tumor status, based on the interpretation of both T1 and T2 weighted images (MR1, MR2 and MR3) in combination with PWI (MR3). Interobserver agreement on visual interpretation of rCBV maps was good (κ = 0.63) but poor on quantitative rCBV measurements and on interpretability of perfusion images (intraclass correlation coefficient 0.37 and κ = 0.23, respectively). Interobserver agreement on the overall conclusion of tumor status was moderate (κ = 0.48). Interobserver agreement on the visual interpretation of PWI color maps was good. However, overall interpretation of MR scans (using both conventional and PW images) showed considerable interobserver variability. Therefore, caution should be applied when interpreting MRI results during chemoradiation therapy. © 2016 EAN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, S; Aerts, H; Berbeco, R
2014-06-15
Purpose: PET-based texture features are used to quantify tumor heterogeneity due to their predictive power in treatment outcome. We investigated the sensitivity of texture features to tumor motion by comparing whole body (3D) and respiratory-gated (4D) PET imaging. Methods: Twenty-six patients (34 lesions) received 3D and 4D [F-18]FDG-PET scans before chemo-radiotherapy. The acquired 4D data were retrospectively binned into five breathing phases to create the 4D image sequence. Four texture features (Coarseness, Contrast, Busyness, and Complexity) were computed within the the physician-defined tumor volume. The relative difference (δ) in each measure between the 3D- and 4D-PET imaging was calculated. Wilcoxonmore » signed-rank test (p<0.01) was used to determine if δ was significantly different from zero. Coefficient of variation (CV) was used to determine the variability in the texture features between all 4D-PET phases. Pearson correlation coefficient was used to investigate the impact of tumor size and motion amplitude on δ. Results: Significant differences (p<<0.01) between 3D and 4D imaging were found for Coarseness, Busyness, and Complexity. The difference for Contrast was not significant (p>0.24). 4D-PET increased Busyness (∼20%) and Complexity (∼20%), and decreased Coarseness (∼10%) and Contrast (∼5%) compared to 3D-PET. Nearly negligible variability (CV=3.9%) was found between the 4D phase bins for Coarseness and Complexity. Moderate variability was found for Contrast and Busyness (CV∼10%). Poor correlation was found between the tumor volume and δ for the texture features (R=−0.34−0.34). Motion amplitude had moderate impact on δ for Contrast and Busyness (R=−0.64− 0.54) and no impact for Coarseness and Complexity (R=−0.29−0.17). Conclusion: Substantial differences in textures were found between 3D and 4D-PET imaging. Moreover, the variability between phase bins for Coarseness and Complexity was negligible, suggesting that similar quantification can be obtained from all phases. Texture features, blurred out by respiratory motion during 3D-PET acquisition, can be better resolved by 4D-PET imaging with any phase.« less
Pandey, Anil K; Bisht, Chandan S; Sharma, Param D; ArunRaj, Sreedharan Thankarajan; Taywade, Sameer; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh
2017-11-01
Tc-methylene diphosphonate (Tc-MDP) bone scintigraphy images have limited number of counts per pixel. A noise filtering method based on local statistics of the image produces better results than a linear filter. However, the mask size has a significant effect on image quality. In this study, we have identified the optimal mask size that yields a good smooth bone scan image. Forty four bone scan images were processed using mask sizes 3, 5, 7, 9, 11, 13, and 15 pixels. The input and processed images were reviewed in two steps. In the first step, the images were inspected and the mask sizes that produced images with significant loss of clinical details in comparison with the input image were excluded. In the second step, the image quality of the 40 sets of images (each set had input image, and its corresponding three processed images with 3, 5, and 7-pixel masks) was assessed by two nuclear medicine physicians. They selected one good smooth image from each set of images. The image quality was also assessed quantitatively with a line profile. Fisher's exact test was used to find statistically significant differences in image quality processed with 5 and 7-pixel mask at a 5% cut-off. A statistically significant difference was found between the image quality processed with 5 and 7-pixel mask at P=0.00528. The identified optimal mask size to produce a good smooth image was found to be 7 pixels. The best mask size for the John-Sen Lee filter was found to be 7×7 pixels, which yielded Tc-methylene diphosphonate bone scan images with the highest acceptable smoothness.
Poore, Joshua C.; Barbey, Aron K.; Krueger, Frank; Solomon, Jeffrey; Lipsky, Robert H.; Hodgkinson, Colin A.; Goldman, David; Grafman, Jordan
2012-01-01
This study examined the role of orbitofrontal cortex (OFC) and dorsolateral prefrontal cortex (DLPFC) plasticity in controlling implicit and explicit social biases. Normal controls and patients with varied OFC and DLPFC lesion size and single nucleotide polymorphisms (SNPs) in the brain-derived neurotrophic factor (BDNF) gene, which promotes (methionine–valine [Met/Val] SNP) or stifles (valine–valine [Val/Val] SNP) plasticity in damaged PFC regions, completed measures of implicit and explicit social bias. Patients and controls demonstrated comparable levels of implicit bias, but patients with Met/Val SNPs exhibited less implicit bias when they had smaller OFC lesions compared with Val/Val patients with similar size lesions and those with large OFC lesions. Both patients and controls demonstrated patterns of explicit bias consistent with hypotheses. Patients with Met/Val SNPs exhibited less explicit bias when they had smaller DLPFC lesions sizes compared with Val/Val patients with similar size lesions and those with large DLPFC lesions. OFC lesion size and BDNF SNP type did not moderate explicit bias; DLPFC lesion size and BDNF SNP type did not moderate implicit bias (nor did other medial or lateral regions). Findings suggest that plasticity within specific PFC regions modulates the type and degree of social bias that individuals’ exhibit. PMID:22123938
Jupiter's Northern Hemisphere in a Methane Band (Time Set 2)
NASA Technical Reports Server (NTRS)
1997-01-01
Mosaic of Jupiter's northern hemisphere between 10 and 50 degrees latitude. Jupiter's atmospheric circulation is dominated by alternating eastward and westward jets from equatorial to polar latitudes. The direction and speed of these jets in part determine the color and texture of the clouds seen in this mosaic. Also visible are several other common Jovian cloud features, including large white ovals, bright spots, dark spots, interacting vortices, and turbulent chaotic systems. The north-south dimension of each of the two interacting vortices in the upper half of the mosaic is about 3500 kilometers. Light at 727 nanometers is moderately absorbed by atmospheric methane. This mosaic shows the features of Jupiter's main visible cloud deck and upper-tropospheric haze, with higher features enhanced in brightness over lower features.
North is at the top. The images are projected on a sphere, with features being foreshortened towards the north. The smallest resolved features are tens of kilometers in size. These images were taken on April 3, 1997, at a range of 1.4 million kilometers by the Solid State Imaging system on NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoPatient comfort from the technologist perspective: factors to consider in mammographic imaging
Mendat, Christina C; Mislan, Dave; Hession-Kunz, Lisa
2017-01-01
A sample size of 280 certified mammography technologists were surveyed to understand what factors affect patient discomfort during breast imaging. Given mammography technologists’ level of patient involvement, they are uniquely positioned to observe factors that affect patient comfort. The findings suggest that according to technologists, multiple factors, including patient ethnicity, breast density, previous biopsy and lumpectomy experience, as well as psychological factors, impact breast discomfort during mammography. Additionally, with respect to imaging protocols, technologists attributed 80% of moderate-to-extreme discomfort to “length of compression time” (27%) and “compression force” (53%). Technologists also attributed “pinching at chest wall” and “hard edges of breast platform” to “very high” discomfort significantly more times (P<0.05) than “coolness and edges of paddle”. These findings confirm some of what has been reported to date and challenge other findings. Given that recent decline in breast cancer mortality has been attributed to improvements in early detection and treatment, approaches to reduce discomfort should be considered in order to promote screening compliance. Although more research is needed, it is apparent that the patient experience of comfort and pain during mammography is an area warranting increased research and solutions. PMID:28572739
A miniature low-cost LWIR camera with a 160×120 microbolometer FPA
NASA Astrophysics Data System (ADS)
Tepegoz, Murat; Kucukkomurler, Alper; Tankut, Firat; Eminoglu, Selim; Akin, Tayfun
2014-06-01
This paper presents the development of a miniature LWIR thermal camera, MSE070D, which targets value performance infrared imaging applications, where a 160x120 CMOS-based microbolometer FPA is utilized. MSE070D features a universal USB interface that can communicate with computers and some particular mobile devices in the market. In addition, it offers high flexibility and mobility with the help of its USB powered nature, eliminating the need for any external power source, thanks to its low-power requirement option. MSE070D provides thermal imaging with its 1.65 inch3 volume with the use of a vacuum packaged CMOS-based microbolometer type thermal sensor MS1670A-VP, achieving moderate performance with a very low production cost. MSE070D allows 30 fps thermal video imaging with the 160x120 FPA size while resulting in an NETD lower than 350 mK with f/1 optics. It is possible to obtain test electronics and software, miniature camera cores, complete Application Programming Interfaces (APIs) and relevant documentation with MSE070D, as MikroSens want to help its customers to evaluate its products and to ensure quick time-to-market for systems manufacturers.
ERIC Educational Resources Information Center
Ng, Thomas W. H.; Feldman, Daniel C.
2011-01-01
Utilizing a meta-analytical approach for testing moderating effects, the current study investigated organizational tenure as a moderator in the relation between affective organizational commitment and organizational citizenship behavior (OCB). We observed that, across 40 studies (N = 11,416 respondents), the effect size for the relation between…
3D-HST+CANDELS: The Evolution of the Galaxy Size-Mass Distribution since z = 3
NASA Astrophysics Data System (ADS)
van der Wel, A.; Franx, M.; van Dokkum, P. G.; Skelton, R. E.; Momcheva, I. G.; Whitaker, K. E.; Brammer, G. B.; Bell, E. F.; Rix, H.-W.; Wuyts, S.; Ferguson, H. C.; Holden, B. P.; Barro, G.; Koekemoer, A. M.; Chang, Yu-Yen; McGrath, E. J.; Häussler, B.; Dekel, A.; Behroozi, P.; Fumagalli, M.; Leja, J.; Lundgren, B. F.; Maseda, M. V.; Nelson, E. J.; Wake, D. A.; Patel, S. G.; Labbé, I.; Faber, S. M.; Grogin, N. A.; Kocevski, D. D.
2014-06-01
Spectroscopic+photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and we find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, R effvprop(1 + z)-1.48, and moderate evolution for the late-type population, R effvprop(1 + z)-0.75. The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, R_{eff}\\propto M_*^{0.22}, for late-type galaxies with stellar mass >3 × 109 M ⊙, and steep, R_{eff}\\propto M_*^{0.75}, for early-type galaxies with stellar mass >2 × 1010 M ⊙. The intrinsic scatter is lsim0.2 dex for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric but is skewed toward small sizes: at all redshifts and masses, a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (~1011 M ⊙), compact (R eff < 2 kpc) early-type galaxies increases from z = 3 to z = 1.5-2 and then strongly decreases at later cosmic times.
Zhanqing Li; Feng Niu; Kwon-Ho Lee; Jinyuan Xin; Wei Min Hao; Bryce L. Nordgren; Yuesi Wang; Pucai Wang
2007-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) currently provides the most extensive aerosol retrievals on a global basis, but validation is limited to a small number of ground stations. This study presents a comprehensive evaluation of Collection 4 and 5 MODIS aerosol products using ground measurements from the Chinese Sun Hazemeter Network (CSHNET). The...
Li, Jingyang; Wen, Zhenhua; Cai, Anlie; Tian, Feng; Zhang, Liang; Luo, Xiaowen; Deng, Li; He, Jingyun; Yang, Yicheng; Chen, Wendong
2017-05-01
To assess the cost-effectiveness of infliximab-containing therapy (ICT) for moderate-to-severe rheumatoid arthritis (RA) in a medium-sized Chinese city. A Chinese prospective cohort study comparing ICT (25 patients) versus conventional disease-modified antirheumatic drugs (24 patients) for RA was used to assess the cost-effectiveness of ICT. The cohort study observed significantly reduced disease activity score of 28 joints (coefficient -2.718, p < 0.001), improved EQ-5D (coefficient 0.453, p < 0.001) and increased medical costs (coefficient 1.289, p < 0.001) associated with ICT. The incremental cost-effectiveness ratio per gained quality-adjusted life year for ICT versus disease-modified antirheumatic drugs was 1.897-times of the local gross domestic product per capita. Infliximab was a favorable cost-effective alternative option for moderate-to-severe RA in a medium-sized city of China.
Skalická, Věra; Belsky, Jay; Stenseng, Frode; Wichstrøm, Lars
2015-01-01
In this Norwegian study, bidirectional relations between children's behavior problems and child-teacher conflict and closeness were examined, and the possibility of moderation of these associations by child-care group size was tested. Eight hundred and nineteen 4-year-old children were followed up in first grade. Results revealed reciprocal effects linking child-teacher conflict and behavior problems. Effects of child-teacher closeness on later behavior problems were moderated by group size: For children in small groups only (i.e., ≤ 15 children), greater closeness predicted reduced behavior problems in first grade. In consequence, stability of behavior problems was greater in larger than in smaller groups. Results are discussed in light of regulatory mechanisms and social learning theory, with possible implications for organization of child care. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.
Soft x-ray imager (SXI) onboard the NeXT satellite
NASA Astrophysics Data System (ADS)
Tsuru, Takeshi Go; Takagi, Shin-Ichiro; Matsumoto, Hironori; Inui, Tatsuya; Ozawa, Midori; Koyama, Katsuji; Tsunemi, Hiroshi; Hayashida, Kiyoshi; Miyata, Emi; Ozawa, Hideki; Touhiguchi, Masakuni; Matsuura, Daisuke; Dotani, Tadayasu; Ozaki, Masanobu; Murakami, Hiroshi; Kohmura, Takayoshi; Kitamoto, Shunji; Awaki, Hisamitsu
2006-06-01
We give overview and the current status of the development of the Soft X-ray Imager (SXI) onboard the NeXT satellite. SXI is an X-ray CCD camera placed at the focal plane detector of the Soft X-ray Telescopes for Imaging (SXT-I) onboard NeXT. The pixel size and the format of the CCD is 24 x 24μm (IA) and 2048 x 2048 x 2 (IA+FS). Currently, we have been developing two types of CCD as candidates for SXI, in parallel. The one is front illumination type CCD with moderate thickness of the depletion layer (70 ~ 100μm) as a baseline plan. The other one is the goal plan, in which we develop back illumination type CCD with a thick depletion layer (200 ~ 300μm). For the baseline plan, we successfully developed the proto model 'CCD-NeXT1' with the pixel size of 12μm x 12μm and the CCD size of 24mm x 48mm. The depletion layer of the CCD has reached 75 ~ 85μm. The goal plan is realized by introduction of a new type of CCD 'P-channel CCD', which collects holes in stead of electrons in the common 'N-channel CCD'. By processing a test model of P-channel CCD we have confirmed high quantum efficiency above 10 keV with an equivalent depletion layer of 300μm. A back illumination type of P-channel CCD with a depletion layer of 200μm with aluminum coating for optical blocking has been also successfully developed. We have been also developing a thermo-electric cooler (TEC) with the function of the mechanically support of the CCD wafer without standoff insulators, for the purpose of the reduction of thermal input to the CCD through the standoff insulators. We have been considering the sensor housing and the onboard electronics for the CCD clocking, readout and digital processing of the frame date.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna
2012-10-15
Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to scoremore » the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.« less
Zhou, Xiang; Chen, Ruohua; Huang, Gang; Liu, Jianjun
2017-01-01
We assessed the clinical value of 2-fluoro-2-deoxyglucose (18F-FDG) PET/CT imaging for predicting occult nodal metastasis in non-small cell lung cancer (NSCLC) patients. This retrospective study included 54 patients with T1-2N0M0 NSCLC who had undergone 18F-FDG PET/CT before surgery. Occult nodal metastasis was detected in 25.9% (14/54) of the patients. Immunohistochemical analysis revealed that increased glucose transporter 1 expression was associated with occult nodal metastasis, but hexokinase 2 expression was not. Compared to the negative nodal metastasis group, the positive nodal metastasis group was associated with increased maximum standardized uptake value (SUVmax) and tumor size. Multivariate analysis indicated that SUVmax and tumor size were associated with nodal metastasis. Nodal metastasis could be predicted with a sensitivity of 92.9% and a specificity of 55.0% when the SUVmax cutoff was 4.35. When patients were divided into low-risk (tumor size ≤ 2.5 cm and SUVmax ≤ 4.35), moderate-risk (tumor size ≤ 2.5 cm and SUVmax > 4.35 or tumor size > 2.5 cm and SUVmax ≤ 4.35) and high-risk (tumor size > 2.5 cm and SUVmax > 4.35) groups, the lymph node metastasis rates were 4.3%, 22.7%, and 88.9%, respectively. These results indicate that the combination of SUVmax and tumor size has potential clinical value for predicting occult nodal metastasis in NSCLC patients. PMID:29137276
Abdoli, Sherwin; Ho, Leon C; Zhang, Jevin W; Dong, Celia M; Lau, Condon; Wu, Ed X
2016-12-01
This study investigated neuroanatomical changes following long-term acoustic exposure at moderate sound pressure level (SPL) under passive conditions, without coupled behavioral training. The authors utilized diffusion tensor imaging (DTI) to detect morphological changes in white matter. DTIs from adult rats (n = 8) exposed to continuous acoustic exposure at moderate SPL for 2 months were compared with DTIs from rats (n = 8) reared under standard acoustic conditions. Two distinct forms of DTI analysis were applied in a sequential manner. First, DTI images were analyzed using voxel-based statistics which revealed greater fractional anisotropy (FA) of the pyramidal tract and decreased FA of the tectospinal tract and trigeminothalamic tract of the exposed rats. Region of interest analysis confirmed (p < 0.05) that FA had increased in the pyramidal tract but did not show a statistically significant difference in the FA of the tectospinal or trigeminothalamic tract. The results of the authors show that long-term and passive acoustic exposure at moderate SPL increases the organization of white matter in the pyramidal tract.
Lucas-Thompson, Rachel G; Goldberg, Wendy A; Prause, JoAnn
2010-11-01
This meta-analysis of 69 studies (1,483 effect sizes) used random effects models to examine maternal employment during infancy/early childhood in relation to 2 major domains of child functioning: achievement and behavior problems. Analyses of studies that spanned 5 decades indicated that, with a few exceptions, early employment was not significantly associated with later achievement or internalizing/externalizing behaviors. The exceptions were for teacher ratings of achievement and internalizing behaviors: Employment was associated with higher achievement and fewer internalizing behaviors. Substantial heterogeneity among the effect sizes prompted examination of moderators. Sample-level moderator analyses pointed to the importance of socioeconomic and contextual variables, with early employment most beneficial when families were challenged by single parenthood or welfare status. Maternal employment during Years 2 and 3 was associated with higher achievement. Some moderator analyses indicated negative effects of employment for middle-class and 2-parent families and for very early employment (child's first year). Associations also differed depending on whether effect sizes were adjusted for contextual variables. Only 1 study-level moderator (sex of first author) was significant after adjusting for other moderators. The small effect size and primarily nonsignificant results for main effects of early maternal employment should allay concerns about mothers working when children are young. However, negative findings associated with employment during the child's first year are compatible with calls for more generous maternal leave policies. Results highlight the importance of social context for identifying under which conditions and for which subgroups early maternal employment is associated with positive or negative child outcomes.
Scattering Properties of Needle-Like and plate-like Ice Spheroids with Moderate Size Parameters
NASA Technical Reports Server (NTRS)
Zakharova, Nadia T.; Mishchenko, Michael I.; Hansen, James E. (Technical Monitor)
2000-01-01
We use the current advanced version of the T-matrix method to compute the optical cross sections, the asymmetry parameter of the phase function, and the scattering matrix elements of ice spheroids with aspect ratios up to 20 and surface-equivalent-sphere size parameters up to 12. We demonstrate that plate-like and needle-like particles with moderate size parameters possess unique scattering properties: their asymmetry parameters and phase functions are similar to those of surface-equivalent spheres, whereas all other elements of the scattering matrix are typical of particles much smaller than the wavelength (Rayleigh scatterers). This result may have important implications for optical particle sizing and remote sensing of the terrestrial and planetary atmospheres.
3-D Synthetic Microstructure Generation with Ellipsoid Particles
2016-09-27
MATLAB scripts in Appendix A, Appendix B, and Appendix C by using 3 -D matrices, where the background is 0 and the particle is 1. For the 3 -D ellipses, it...iy(iy== 0 )=image_size(2); nlo = z0 - floor(diam/2); nhi = z0 + ceil(diam/2)-1; iz = mod(nlo:nhi,image_size( 3 ));iz(iz== 0 )=image_size( 3 ); Itest = logical...z0 + ceil(diam/2)-1; iz = mod(nlo:nhi,image_size( 3 )); iz(iz== 0 )=image_size( 3 ); Itest = logical(I(ix,iy,iz)); if sum(Itest(I_ellipse)) == 0 Itest
Conn, Vicki S; Ruppar, Todd M; Chase, Jo-Ana D; Enriquez, Maithe; Cooper, Pamela S
2015-12-01
This systematic review applied meta-analytic procedures to synthesize medication adherence interventions that focus on adults with hypertension. Comprehensive searching located trials with medication adherence behavior outcomes. Study sample, design, intervention characteristics, and outcomes were coded. Random-effects models were used in calculating standardized mean difference effect sizes. Moderator analyses were conducted using meta-analytic analogues of ANOVA and regression to explore associations between effect sizes and sample, design, and intervention characteristics. Effect sizes were calculated for 112 eligible treatment-vs.-control group outcome comparisons of 34,272 subjects. The overall standardized mean difference effect size between treatment and control subjects was 0.300. Exploratory moderator analyses revealed interventions were most effective among female, older, and moderate- or high-income participants. The most promising intervention components were those linking adherence behavior with habits, giving adherence feedback to patients, self-monitoring of blood pressure, using pill boxes and other special packaging, and motivational interviewing. The most effective interventions employed multiple components and were delivered over many days. Future research should strive for minimizing risks of bias common in this literature, especially avoiding self-report adherence measures.
Mild, Moderate, Severe Asthma: What Do Grades Mean?
... Text Size Email Print Share Mild, Moderate, Severe Asthma: What Do Grades Mean? Page Content Article Body ... is when assessed at follow-up visits. Intermittent Asthma A child who has symptoms of wheezing and ...
Rieger, Elizabeth; Dolan, Ashleigh; Thomas, Brittany; Bell, Jason
2017-09-01
Interpersonal dysfunction and weight/shape-based self-worth have been implicated as key constructs for eating disorders, although the relationship between these two concepts is under-researched. This study investigated the moderating role of weight/shape-based self-worth in terms of the impact of interpersonal rejection on attentional bias regarding thin-ideal and non-thin images. Participants were 94 females without an eating disorder, who were exposed to either interpersonal rejection or acceptance (using the Cyberball paradigm), and subsequently assessed in terms of their attentional biases regarding thin-ideal and non-thin images. Results revealed that weight/shape-based self-worth moderated the relationship between interpersonal rejection/acceptance and attentional biases for thin-ideal (but not non-thin) images. Specifically, participants with a greater tendency to base their self-worth on weight/shape demonstrated reduced avoidance of thin-ideal images when rejected relative to those who were accepted. The findings support the role of interpersonal rejection in eliciting attentional disturbances among those with higher body weight/shape-based self-worth. Copyright © 2017 Elsevier Ltd. All rights reserved.
Evaluation of physiological strain in hot work areas using thermal imagery.
Holm, Clint A; Pahler, Leon; Thiese, Matthew S; Handy, Rodney
2016-10-01
Monitoring core body temperature to identify heat strain in workers engaged in hot work in heat stress environments is intrusive and expensive. Nonintrusive, inexpensive methods are needed to calculate individual Physiological Strain Index (PSI). Thermal imaging and heart rate monitoring were used in this study to calculate Physiological Strain Index (PSI) from thermal imaging temperatures of human subjects wearing thermal protective garments during recovery from hot work. Ten male subjects were evaluated for physiological strain while participating in hot work. Thermal images of the head and neck were captured with a high-resolution thermal imaging camera concomitant with measures of gastrointestinal and skin temperature. Lin's concordance correlation coefficient (rho_c), Pearson's coefficient (r) and bias correction factor (C-b) were calculated to compare thermal imaging based temperatures to gastrointestinal temperatures. Calculations of PSI based thermal imaging recorded temperatures were compared to gastrointestinal based PSI. Participants reached a peak PSI of 5.2, indicating moderate heat strain. Sagittal measurements showed low correlation (rho_c=0.133), moderate precision (r=0.496) and low accuracy (C_b=0.269) with gastrointestinal temperature. Bland-Altman plots of imaging measurements showed increasing agreement as gastrointestinal temperature rose; however, the Limits of Agreement (LoA) fell outside the ±0.25C range of clinical significance. Bland-Altman plots of PSI calculated from imaging measurements showed increasing agreement as gastrointestinal temperature rose; however, the LoA fell outside the ±0.5 range of clinical significance. Results of this study confirmed previous research showing thermal imagery is not highly correlated to body core temperature during recovery from moderate heat strain in mild ambient conditions. Measurements display a trend toward increasing correlation at higher body core temperatures. Accuracy was not sufficient at mild to moderate heat strain to allow calculation of individual physiological stress. Copyright © 2016 Elsevier Ltd. All rights reserved.
12 CFR 1282.19 - Affordability-Rent level definitions-tenant income is not known.
Code of Federal Regulations, 2010 CFR
2010-01-01
... very low-, low-, or moderate-income families where the income of the family in the dwelling unit is not known to the Enterprise, the affordability of the unit is determined based on unit size as follows: (a) For moderate-income, maximum affordable rents to count as housing for moderate-income families shall...
Haraldsdóttir, K H; Jónsson, Þ; Halldórsdóttir, A B; Tranberg, K-G; Ásgeirsson, K S
2017-03-01
In Landspitali University Hospital, magnetic resonance imaging is used non-selectively in addition to mammogram and ultrasound in the preoperative assessment of breast cancer patients. The aim of this study was to assess invasive tumor size on imaging, compare with pathological size and evaluate the impact of magnetic resonance imaging on the type of surgery performed. All women with invasive breast cancer, diagnosed in Iceland, between 2007 and 2009 were reviewed retrospectively. In all, 438 of 641 (68%) patients diagnosed had preoperative magnetic resonance imaging. Twelve patients treated with neoadjuvant chemotherapy were excluded and 65 patients with multifocal or contralateral disease were assessed separately. Correlations between microscopic and radiologic tumor sizes were relatively weak. All imaging methods were inaccurate especially for large tumors, resulting in an overall underestimation of tumor size for these tumors. Magnetic resonance imaging under- and overestimated pathological tumor size by more than 10 mm in 16/348 (4.6%) and 26/348 patients (7.5%), respectively. In 19 patients (73%), overestimation of size was seen exclusively on magnetic resonance imaging. For tumors under- or overestimated by magnetic resonance imaging, the mastectomy rates were 56% and 65%, respectively, compared to an overall mastectomy rate of 43%. Of 51 patients diagnosed with multifocal disease on pathology, 19 (37%) were diagnosed by mammogram or ultrasound and 40 (78%) by magnetic resonance imaging resulting in a total detection rate of 84% (43 patients). Fourteen (3%) patients were diagnosed preoperatively with contralateral disease. Of those tumors, all were detected on magnetic resonance imaging but seven (50%) were also detected on mammogram or ultrasound or both. Our results suggest that routine use of magnetic resonance imaging may result in both under- and overestimation of tumor size and increase mastectomy rates in a small proportion of patients. Magnetic resonance imaging aids in the diagnosis of contralateral and multifocal disease.
Smith, M A; Dyson, S J; Murray, R C
2012-11-01
To determine the reliability of 2 magnetic resonance imaging (MRI) systems for detection of cartilage and bone lesions of the equine fetlock. To test the hypotheses that lesions in cartilage, subchondral and trabecular bone of the equine fetlock verified using histopathology can be detected on high- and low-field MR images with a low incidence of false positive or negative results; that low-field images are less reliable than high-field images for detection of cartilage lesions; and that combining results of interpretation from different pulse sequences increases detection of cartilage lesions. High- and low-field MRI was performed on 19 limbs from horses identified with fetlock lameness prior to euthanasia. Grading systems were used to score cartilage, subchondral and trabecular bone on MR images and histopathology. Sensitivity and specificity were calculated for images. High-field T2*-weighted gradient echo (T2*W-GRE) and low-field T2-weighted fast spin echo (T2W-FSE) images had high sensitivity but low specificity for detection of cartilage lesions. All pulse sequences had high sensitivity and low-moderate specificity for detection of subchondral bone lesions and moderate sensitivity and moderate-high specificity for detection of trabecular bone lesions (histopathology as gold standard). For detection of lesions of trabecular bone low-field T2*W-GRE images had higher sensitivity and specificity than T2W-FSE images. There is high likelihood of false positive results using high- or low-field MRI for detection of cartilage lesions and moderate-high likelihood of false positive results for detection of subchondral bone lesions compared with histopathology. Combining results of interpretation from different pulse sequences did not increase detection of cartilage lesions. MRI interpretation of trabecular bone was more reliable than cartilage or subchondral bone in both MR systems. Independent interpretation of a variety of pulse sequences may maximise detection of cartilage and bone lesions in the fetlock. Clinicians should be aware of potential false positive and negative results. © 2012 EVJ Ltd.
NASA Technical Reports Server (NTRS)
Brickey, David W.; Crowley, James K.; Rowan, Lawrence C.
1987-01-01
Airborne Imaging Spectrometer-1 (AIS-1) data were obtained for an area of amphibolite grade metamorphic rocks that have moderate rangeland vegetation cover. Although rock exposures are sparse and patchy at this site, soils are visible through the vegetation and typically comprise 20 to 30 percent of the surface area. Channel averaged low band depth images for diagnostic soil rock absorption bands. Sets of three such images were combined to produce color composite band depth images. This relative simple approach did not require extensive calibration efforts and was effective for discerning a number of spectrally distinctive rocks and soils, including soils having high talc concentrations. The results show that the high spectral and spatial resolution of AIS-1 and future sensors hold considerable promise for mapping mineral variations in soil, even in moderately vegetated areas.
Gadolinium oxide nanoplates with high longitudinal relaxivity for magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Cho, Minjung; Sethi, Richa; Ananta Narayanan, Jeyarama Subramanian; Lee, Seung Soo; Benoit, Denise N.; Taheri, Nasim; Decuzzi, Paolo; Colvin, Vicki L.
2014-10-01
Molecular-based contrast agents for magnetic resonance imaging (MRI) are often characterized by insufficient relaxivity, thus requiring the systemic injection of high doses to induce sufficient contrast enhancement at the target site. In this work, gadolinium oxide (Gd2O3) nanoplates are produced via a thermal decomposition method. The nanoplates have a core diameter varying from 2 to 22 nm, a thickness of 1 to 2 nm and are coated with either an oleic acid bilayer or an octylamine modified poly(acrylic acid) (PAA-OA) polymer layer. For the smaller nanoplates, longitudinal relaxivities (r1) of 7.96 and 47.2 (mM s)-1 were measured at 1.41 T for the oleic acid bilayer and PAA-OA coating, respectively. These values moderately reduce as the size of the Gd2O3 nanoplates increases, and are always larger for the PAA-OA coating. Cytotoxicity studies on human dermal fibroblast cells documented no significant toxicity, with 100% cell viability preserved up to 250 μM for the PAA-OA coated Gd2O3 nanoplates. Given the 10 times increase in longitudinal relaxivity over the commercially available Gd-based molecular agents and the favorable toxicity profile, the 2 nm PAA-OA coated Gd2O3 nanoplates could represent a new class of highly effective T1 MRI contrast agents.Molecular-based contrast agents for magnetic resonance imaging (MRI) are often characterized by insufficient relaxivity, thus requiring the systemic injection of high doses to induce sufficient contrast enhancement at the target site. In this work, gadolinium oxide (Gd2O3) nanoplates are produced via a thermal decomposition method. The nanoplates have a core diameter varying from 2 to 22 nm, a thickness of 1 to 2 nm and are coated with either an oleic acid bilayer or an octylamine modified poly(acrylic acid) (PAA-OA) polymer layer. For the smaller nanoplates, longitudinal relaxivities (r1) of 7.96 and 47.2 (mM s)-1 were measured at 1.41 T for the oleic acid bilayer and PAA-OA coating, respectively. These values moderately reduce as the size of the Gd2O3 nanoplates increases, and are always larger for the PAA-OA coating. Cytotoxicity studies on human dermal fibroblast cells documented no significant toxicity, with 100% cell viability preserved up to 250 μM for the PAA-OA coated Gd2O3 nanoplates. Given the 10 times increase in longitudinal relaxivity over the commercially available Gd-based molecular agents and the favorable toxicity profile, the 2 nm PAA-OA coated Gd2O3 nanoplates could represent a new class of highly effective T1 MRI contrast agents. Electronic supplementary information (ESI) available: The histograms of Gd2O3 nanoparticles ranging from 2 to 22 nm, TEM image of 22 nm gadolinium oxide with GIF mapping, size control by reaction parameter, XPS and XRD of Gd2O3 nanoparticles, phase transfer yields of oleic acid and PAA-OA coated Gd2O3 nanoparticles, hydrodynamic size and zeta potentials with table, long-term stability test at different temperature, buffer, pH, and ionic strength conditions with tables. See DOI: 10.1039/c4nr03505d
2013-01-01
Background Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated 2D images with gold standard values obtained from 3D CT data; to determine the sensitivity of the 2D measurements to mal-positioning of the ankle during imaging; and to quantify the repeatability of the 2D measurements under simulated positioning conditions involving random errors. Method Fifty-eight cadaveric ankles fixed in the neutral joint position (standard pose) were CT scanned, and the data were used to simulate lateral and frontal radiographs under various positioning conditions using digitally reconstructed radiographs (DRR). Results and discussion In the standard pose for imaging, most ankle morphometric parameters measured using 2D images were highly correlated (R > 0.8) to the gold standard values defined by the 3D CT data. For measurements made on the lateral views, the only parameters sensitive to rotational pose errors were longitudinal distances between the most anterior and the most posterior points of the tibial mortise and the tibial profile, which have important implications for determining the optimal cutting level of the bone during arthroplasty. Measurements of the trochlea tali width on the frontal views underestimated the standard values by up to 31.2%, with only a moderate reliability, suggesting that pre-surgical evaluations based on the trochlea tali width should be made with caution in order to avoid inappropriate selection of prosthesis sizes. Conclusions While highly correlated with 3D morphological measurements, some 2D measurements were affected by the bone poses in space during imaging, which may affect surgical decision-making in total ankle arthroplasty, including the amount of bone resection and the selection of the implant sizes. The linear regression equations for the relationship between 2D and 3D measurements will be helpful for correcting the errors in 2D morphometric measurements for clinical applications. PMID:24359413
Measuring droplet size distributions from overlapping interferometric particle images.
Bocanegra Evans, Humberto; Dam, Nico; van der Voort, Dennis; Bertens, Guus; van de Water, Willem
2015-02-01
Interferometric particle imaging provides a simple way to measure the probability density function (PDF) of droplet sizes from out-focus images. The optical setup is straightforward, but the interpretation of the data is a problem when particle images overlap. We propose a new way to analyze the images. The emphasis is not on a precise identification of droplets, but on obtaining a good estimate of the PDF of droplet sizes in the case of overlapping particle images. The algorithm is tested using synthetic and experimental data. We next use these methods to measure the PDF of droplet sizes produced by spinning disk aerosol generators. The mean primary droplet diameter agrees with predictions from the literature, but we find a broad distribution of satellite droplet sizes.
What made discy galaxies giant?
NASA Astrophysics Data System (ADS)
Saburova, A. S.
2018-01-01
I studied giant discy galaxies with optical radii more than 30 kpc. The comparison of these systems with discy galaxies of moderate sizes revealed that they tend to have higher rotation velocities, B-band luminosities, H I masses and dark-to-luminous mass ratios. The giant discs follow the trend log (M_{H I})(R_{25}) found for normal sized galaxies. It indicates the absence of the peculiarities of evolution of star formation in these galaxies. The H I mass-to-luminosity ratio of giant galaxies appears not to differ from that of normal-sized galaxies, giving evidence in favour of similar star formation efficiency. I also found that the bars and rings occur more frequently among giant discs. I performed mass modelling of the subsample of 18 giant galaxies with available rotation curves and surface photometry data and constructed χ2 maps for the parameters of their dark matter haloes. These estimates indicate that giant discs tend to be formed in larger more massive and rarified dark haloes in comparison to moderate-sized galaxies. However, giant galaxies do not deviate significantly from the relations between the optical sizes and dark halo parameters for moderate-sized galaxies. These findings can rule out the catastrophic scenario of the formation of at least most of giant discs, since they follow the same relations as normal discy galaxies. The giant sizes of the discs can be due to the high radial scale of the dark matter haloes in which they were formed.
A meta-analysis of family accommodation and OCD symptom severity.
Wu, Monica S; McGuire, Joseph F; Martino, Charitie; Phares, Vicky; Selles, Robert R; Storch, Eric A
2016-04-01
Family accommodation in obsessive-compulsive disorder (OCD) is characterized by myriad behaviors, such as modifying family routines, facilitating avoidance, and engaging in compulsions to reduce obsessional distress. It has been linked to various deleterious outcomes including increased functional impairment and poorer treatment response for OCD. Although extant literature suggests a linear relationship between family accommodation and OCD symptom severity, the magnitude and statistical significance of this association has been inconsistent across studies, indicating that moderators may be influencing this relationship. The present study examined this relationship using meta-analytic techniques, and investigated sample-dependent (age, gender, comorbid anxiety/mood disorders) and methodological (administration method and number of items used in family accommodation measure, informant type, sample size, publication year) moderators. Forty-one studies were included in the present meta-analysis, and the overall effect size (ES) for the correlation between family accommodation and OCD symptom severity was moderate (r=.42). Moderator analyses revealed that the number of items on the family accommodation scale moderated the ES. No other sample-dependent or methodological characteristics emerged as moderators. In addition to being the first systematic examination of family accommodation moderators, these results highlight the moderate relationship between family accommodation and OCD severity that is influenced by measurement scales. Findings may be used to guide clinical care and inform future investigations by providing a more nuanced understanding of family accommodation in OCD. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Lee, Joonsuk; Yang, Ping; Dessler, Andrew E.; Baum, Bryan A.; Platnick, Steven
2005-01-01
Cloud microphysical and optical properties are inferred from the bidirectional reflectances simulated for a single-layered cloud consisting of an external mixture of ice particles and liquid droplets. The reflectances are calculated with a rigorous discrete ordinates radiative transfer model and are functions of the cloud effective particle size, the cloud optical thickness, and the values of the ice fraction in the cloud (i.e., the ratio of ice water content to total water content). In the present light scattering and radiative transfer simulations, the ice fraction is assumed to be vertically homogeneous; the habit (shape) percentage as a function of ice particle size is consistent with that used for the Moderate Resolution Imaging Spectroradiometer (MODIS) operational (Collection 4 and earlier) cloud products; and the surface is assumed to be Lambertian with an albedo of 0.03. Furthermore, error analyses pertaining to the inference of the effective particle sizes and optical thicknesses of mixed-phase clouds are performed. Errors are calculated with respect to the assumption of a cloud containing solely liquid or ice phase particles. The analyses suggest that the effective particle size inferred for a mixed-phase cloud can be underestimated (or overestimated) if pure liquid phase (or pure ice phase) is assumed for the cloud, whereas the corresponding cloud optical thickness can be overestimated (or underestimated).
Absolute stellar photometry on moderate-resolution FPA images
Stone, T.C.
2009-01-01
An extensive database of star (and Moon) images has been collected by the ground-based RObotic Lunar Observatory (ROLO) as part of the US Geological Survey program for lunar calibration. The stellar data are used to derive nightly atmospheric corrections for the observations from extinction measurements, and absolute calibration of the ROLO sensors is based on observations of Vega and published reference flux and spectrum data. The ROLO telescopes were designed for imaging the Moon at moderate resolution, thus imposing some limitations for the stellar photometry. Attaining accurate stellar photometry with the ROLO image data has required development of specialized processing techniques. A key consideration is consistency in discriminating the star core signal from the off-axis point spread function. The analysis and processing methods applied to the ROLO stellar image database are described. ?? 2009 BIPM and IOP Publishing Ltd.
The impact of image-size manipulation and sugar content on children's cereal consumption.
Neyens, E; Aerts, G; Smits, T
2015-12-01
Previous studies have demonstrated that portion sizes and food energy-density influence children's eating behavior. However, the potential effects of front-of-pack image-sizes of serving suggestions and sugar content have not been tested. Using a mixed experimental design among young children, this study examines the effects of image-size manipulation and sugar content on cereal and milk consumption. Children poured and consumed significantly more cereal and drank significantly more milk when exposed to a larger sized image of serving suggestion as compared to a smaller image-size. Sugar content showed no main effects. Nevertheless, cereal consumption only differed significantly between small and large image-sizes when sugar content was low. An advantage of this study was the mundane setting in which the data were collected: a school's dining room instead of an artificial lab. Future studies should include a control condition, with children eating by themselves to reflect an even more natural context. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wang, Zhipeng; Xiong, Xiaoxiong; Li, Yonghong
2015-01-01
Spectral bands of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrumentaboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite are spatially co-registered.The accuracy of the band-to-band registration (BBR) is one of the key spatial parameters that must becharacterized. Unlike its predecessor, the Moderate Resolution Imaging Spectroradiometer (MODIS), VIIRS has no on-board calibrator specifically designed to perform on-orbit BBR characterization.To circumvent this problem, a BBR characterization method for VIIRS reflective solar bands (RSB) based on regularly-acquired lunar images has been developed. While its results can satisfactorily demonstrate that the long-term stability of the BBR is well within +/- 0.1 moderate resolution bandpixels, undesired seasonal oscillations have been observed in the trending. The oscillations are most obvious between the visiblenear-infrared bands and short-middle wave infrared bands. This paper investigates the oscillations and identifies their cause as the band spectral dependence of the centroid position and the seasonal rotation of the lunar images over calibration events. Accordingly, an improved algorithm is proposed to quantify the rotation and compensate for its impact. After the correction, the seasonal oscillation in the resulting BBR is reduced from up to 0.05 moderate resolution band pixels to around 0.01 moderate resolution band pixels. After removing this spurious seasonal oscillation, the BBR, as well as its long-term drift are well determined.
Moderating the Covariance Between Family Member’s Substance Use Behavior
Eaves, Lindon J.; Neale, Michael C.
2014-01-01
Twin and family studies implicitly assume that the covariation between family members remains constant across differences in age between the members of the family. However, age-specificity in gene expression for shared environmental factors could generate higher correlations between family members who are more similar in age. Cohort effects (cohort × genotype or cohort × common environment) could have the same effects, and both potentially reduce effect sizes estimated in genome-wide association studies where the subjects are heterogeneous in age. In this paper we describe a model in which the covariance between twins and non-twin siblings is moderated as a function of age difference. We describe the details of the model and simulate data using a variety of different parameter values to demonstrate that model fitting returns unbiased parameter estimates. Power analyses are then conducted to estimate the sample sizes required to detect the effects of moderation in a design of twins and siblings. Finally, the model is applied to data on cigarette smoking. We find that (1) the model effectively recovers the simulated parameters, (2) the power is relatively low and therefore requires large sample sizes before small to moderate effect sizes can be found reliably, and (3) the genetic covariance between siblings for smoking behavior decays very rapidly. Result 3 implies that, e.g., genome-wide studies of smoking behavior that use individuals assessed at different ages, or belonging to different birth-year cohorts may have had substantially reduced power to detect effects of genotype on cigarette use. It also implies that significant special twin environmental effects can be explained by age-moderation in some cases. This effect likely contributes to the missing heritability paradox. PMID:24647834
An Effect Size Measure for Raju's Differential Functioning for Items and Tests
ERIC Educational Resources Information Center
Wright, Keith D.; Oshima, T. C.
2015-01-01
This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…
NASA Technical Reports Server (NTRS)
2002-01-01
More than 2,000 firefighters continue to battle the 'Viejas Wildfire' which has consumed more than 11,000 acres in the dry, mountainous region just east of San Diego, California. Authorities there believe the blaze may have been started on Wednesday, January 3, by a cigarette thrown from a car on Interstate 8. Shifty winds with gusts of up to 65 miles per hour helped fan and quickly spread the flames. Late Wednesday, eyewitnesses reported seeing thick smoke and dime-sized bits of ash blowing toward downtown San Diego, prompting health officials there to warn residents with respiratory conditions to take necessary precautions. Parts of other communities, such as Alpine, have been evacuated to avoid the rapidly spreading flames. Firefighters estimate that the Viejas Fire, named after a nearby Native American reservation, will be contained by late Saturday, January 6. This image of the wildfire was acquired on January 4, 2001, by the Moderate-resolution Imaging Spectroradiometer (MODIS), flying aboard NASA's Terra spacecraft. The scene shows the wildfire and smoke plume from the Alpine region, east of San Diego. This false-color image was generated using a combination of MODIS' thermal infrared data, at 1-kilometer resolution, along with two of the sensor's 500-meter resolution visible channels. These data were acquired via direct broadcast by the SeaSpace TeraScan SX-EOS receiving station at SeaSpace Corporation in Poway, California. The image was processed, Earth-located and enhanced using TeraScan software. Image courtesy Dave Brooks, SeaSpace Corporation
The Planets Around Low-Mass Stars (PALMS) Direct Imaging Survey
NASA Astrophysics Data System (ADS)
Bowler, Brendan P.; Liu, M. C.; Shkolnik, E.; Mann, A.; Tamura, M.
2013-01-01
Direct imaging is the only method to study the outer architecture (>10 AU) of extrasolar planetary systems in a targeted fashion. Previous imaging surveys have primarily focused on intermediate- and high-mass stars because of the relative dearth of known nearby young M dwarfs. As a result, even though M dwarfs make up 70% of stars in our galaxy, there are few constraints on the population of giant planets at moderate separations (10-100 AU) in this stellar mass regime. We present results from an ongoing high-contrast adaptive optics imaging survey targeting newly identified nearby (<35 pc) young (<300 Myr) M dwarfs with Keck-2/NIRC2 and Subaru/HiCIAO. We have already discovered four young brown dwarf companions with masses between 30-70 Mjup; two of these are members of the ~120 Myr AB Dor moving group, and another one will yield a dynamical mass in the near future. Follow-up optical and near-infrared spectroscopy of these companions reveal spectral types of late-M to early-L and spectroscopic indicators of youth such as angular H-band morphologies, weak J-band alkali lines, and Li absorption and Halpha emission in one target. Altogether our survey is sensitive to planet masses a few times that of Jupiter at separations down to ~10 AU. With a sample size of roughly 80 single M dwarfs, this program represents the deepest and most extensive imaging search for planets around young low-mass stars to date.
NASA Astrophysics Data System (ADS)
Kamlangkeng, Poramate; Asa, Prateepasen; Mai, Noipitak
2014-06-01
Digital radiographic testing is an acceptable premature nondestructive examination technique. Its performance and limitation comparing to the old technique are still not widely well known. In this paper conducted the study on the comparison of the accuracy of the defect size measurement and film quality obtained from film and digital radiograph techniques by testing in specimens and known size sample defect. Initially, one specimen was built with three types of internal defect; which are longitudinal cracking, lack of fusion, and porosity. For the known size sample defect, it was machined various geometrical size for comparing the accuracy of the measuring defect size to the real size in both film and digital images. To compare the image quality by considering at smallest detectable wire and the three defect images. In this research used Image Quality Indicator (IQI) of wire type 10/16 FE EN BS EN-462-1-1994. The radiographic films were produced by X-ray and gamma ray using Kodak AA400 size 3.5x8 inches, while the digital images were produced by Fuji image plate type ST-VI with 100 micrometers resolution. During the tests, a radiator GE model MF3 was implemented. The applied energy is varied from 120 to 220 kV and the current from 1.2 to 3.0 mA. The intensity of Iridium 192 gamma ray is in the range of 24-25 Curie. Under the mentioned conditions, the results showed that the deviation of the defect size measurement comparing to the real size obtained from the digital image radiographs is below than that of the film digitized, whereas the quality of film digitizer radiographs is higher in comparison.
Mannath, J; Subramanian, V; Telakis, E; Lau, K; Ramappa, V; Wireko, M; Kaye, P V; Ragunath, K
2013-02-01
Autofluorescence imaging (AFI), which is a "red flag" technique during Barrett's surveillance, is associated with significant false positive results. The aim of this study was to assess the inter-observer agreement (IOA) in identifying AFI-positive lesions and to assess the overall accuracy of AFI. Anonymized AFI and high resolution white light (HRE) images were prospectively collected. The AFI images were presented in random order, followed by corresponding AFI + HRE images. Three AFI experts and 3 AFI non-experts scored images after a training presentation. The IOA was calculated using kappa and accuracy was calculated with histology as gold standard. Seventy-four sets of images were prospectively collected from 63 patients (48 males, mean age 69 years). The IOA for number of AF positive lesions was fair when AFI images were presented. This improved to moderate with corresponding AFI and HRE images [experts 0.57 (0.44-0.70), non-experts 0.47 (0.35-0.62)]. The IOA for the site of AF lesion was moderate for experts and fair for non-experts using AF images, which improved to substantial for experts [κ = 0.62 (0.50-0.72)] but remained at fair for non-experts [κ = 0.28 (0.18-0.37)] with AFI + HRE. Among experts, the accuracy of identifying dysplasia was 0.76 (0.7-0.81) using AFI images and 0.85 (0.79-0.89) using AFI + HRE images. The accuracy was 0.69 (0.62-0.74) with AFI images alone and 0.75 (0.70-0.80) using AFI + HRE among non-experts. The IOA for AF positive lesions is fair to moderate using AFI images which improved with addition of HRE. The overall accuracy of identifying dysplasia was modest, and was better when AFI and HRE images were combined.
Code of Federal Regulations, 2010 CFR
2010-04-01
... definitions-family size not known (actual or prospective tenants). 81.18 Section 81.18 Housing and Urban... CORPORATION (FREDDIE MAC) Housing Goals § 81.18 Affordability—Income level definitions—family size not known... moderate-income families where family size is not known to the GSE, income will be adjusted using unit size...
Clavagnier, Simon; Dumoulin, Serge O; Hess, Robert F
2015-11-04
The neural basis of amblyopia is a matter of debate. The following possibilities have been suggested: loss of foveal cells, reduced cortical magnification, loss of spatial resolution of foveal cells, and topographical disarray in the cellular map. To resolve this we undertook a population receptive field (pRF) functional magnetic resonance imaging analysis in the central field in humans with moderate-to-severe amblyopia. We measured the relationship between averaged pRF size and retinal eccentricity in retinotopic visual areas. Results showed that cortical magnification is normal in the foveal field of strabismic amblyopes. However, the pRF sizes are enlarged for the amblyopic eye. We speculate that the pRF enlargement reflects loss of cellular resolution or an increased cellular positional disarray within the representation of the amblyopic eye. The neural basis of amblyopia, a visual deficit affecting 3% of the human population, remains a matter of debate. We undertook the first population receptive field functional magnetic resonance imaging analysis in participants with amblyopia and compared the projections from the amblyopic and fellow normal eye in the visual cortex. The projection from the amblyopic eye was found to have a normal cortical magnification factor, enlarged population receptive field sizes, and topographic disorganization in all early visual areas. This is consistent with an explanation of amblyopia as an immature system with a normal complement of cells whose spatial resolution is reduced and whose topographical map is disordered. This bears upon a number of competing theories for the psychophysical defect and affects future treatment therapies. Copyright © 2015 the authors 0270-6474/15/3514740-16$15.00/0.
Practical implementation of channelized hotelling observers: effect of ROI size
NASA Astrophysics Data System (ADS)
Ferrero, Andrea; Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H.
2017-03-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.
Practical implementation of Channelized Hotelling Observers: Effect of ROI size.
Ferrero, Andrea; Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H
2017-03-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.
Size effect of Au/PAMAM contrast agent on CT imaging of reticuloendothelial system and tumor tissue
NASA Astrophysics Data System (ADS)
Wang, Wei; Li, Jian; Liu, Ransheng; Zhang, Aixu; Yuan, Zhiyong
2016-09-01
Polyamidoamine (PAMAM)-entrapped Au nanoparticles were synthesized with distinct sizes to figure out the size effect of Au-based contrast agent on CT imaging of passively targeted tissues. Au/PAMAM nanoparticles were first synthesized with narrow distribution of particles size of 22.2 ± 3.1, 54.2 ± 3.7, and 104.9 ± 4.7 nm in diameters. Size effect leads no significant difference on X-ray attenuation when Au/PAMAM was ≤0.05 mol/L. For CT imaging of a tumor model, small Au/PAMAM were more easily internalized via endocytosis in the liver, leading to more obviously enhanced contrast. Similarly, contrast agents with small sizes were more effective in tumor imaging because of the enhanced permeability and retention effect. Overall, the particle size of Au/PAMAM heavily affected the efficiency of CT enhancement in imaging RES and tumors.
Uribarri-Gonzalez, Laura; Keane, Margaret G; Pereira, Stephen P; Iglesias-García, Julio; Dominguez-Muñoz, J Enrique; Lariño-Noia, Jose
2018-03-01
To evaluate the agreement between the imaging modalities MRI-MRCP and EUS in cystic lesions of the pancreas which were thought to be a BD-IPMN. Multicenter retrospective study included all patients between 2010 and 2015 with a suspected BD-IPMN who underwent an EUS and MRI-MRCP within 6 months or less of each other. Location, number, size, worrisome features and high-risk stigmata were evaluated. Interobserver agreement was evaluated by Kappa score. 173 patients were included (97 UHSC, 76 UCLH-RFH), mean age 65 (range 25-87 years), 66 males. When comparing both modalities there was good agreement for the location of the cyst. The median lesion size was larger by MRI-MRCP than EUS although it was not significant. With regards to worrisome features, there was moderate agreement for main PD of 5-9 mm and abrupt change (k = 0.45 and 0.52). Fair agreement was seen for the cyst wall thickening (k = 0.25). No agreement was seen between the presence of non-enhanced mural nodules or lymphadenopathy (k < 0). With regards to high-risk stigmata, poor agreement was obtained for the detection of an enhanced solid component (k = 0.12). No agreement was observed for main PD > 10 mm (k < 0). In this multicentre study of patients with a BD-IPMN under active surveillance, most disagreement between these modalities was seen in the proximal pancreas. There was generally only minimal concordance between the imaging findings of EUS and MRI-MRCP for the detection of high-risk stigmata and worrisome features. Copyright © 2018 IAP and EPC. All rights reserved.
Global cloud database from VIRS and MODIS for CERES
NASA Astrophysics Data System (ADS)
Minnis, Patrick; Young, David F.; Wielicki, Bruce A.; Sun-Mack, Sunny; Trepte, Qing Z.; Chen, Yan; Heck, Patrick W.; Dong, Xiquan
2003-04-01
The NASA CERES Project has developed a combined radiation and cloud property dataset using the CERES scanners and matched spectral data from high-resolution imagers, the Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission (TRMM) satellite and the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua. The diurnal cycle can be well-characterized over most of the globe using the combinations of TRMM, Aqua, and Terra data. The cloud properties are derived from the imagers using state-of-the-art methods and include cloud fraction, height, optical depth, phase, effective particle size, emissivity, and ice or liquid water path. These cloud products are convolved into the matching CERES fields of view to provide simultaneous cloud and radiation data at an unprecedented accuracy. Results are available for at least 3 years of VIRS data and 1 year of Terra MODIS data. The various cloud products are compared with similar quantities from climatological sources and instantaneous active remote sensors. The cloud amounts are very similar to those from surface observer climatologies and are 6-7% less than those from a satellite-based climatology. Optical depths are 2-3 times smaller than those from the satellite climatology, but are within 5% of those from the surface remote sensing. Cloud droplet sizes and liquid water paths are within 10% of the surface results on average for stratus clouds. The VIRS and MODIS retrievals are very consistent with differences that usually can be explained by sampling, calibration, or resolution differences. The results should be extremely valuable for model validation and improvement and for improving our understanding of the relationship between clouds and the radiation budget.
Thermal imaging and analysis of short-lived Vulcanian explosions at Volcán de Colima, Mexico
NASA Astrophysics Data System (ADS)
Webb, Erica B.; Varley, Nick R.; Pyle, David M.; Mather, Tamsin A.
2014-05-01
Vulcanian explosions present a major hazard at many active volcanoes, but they also provide useful insights into the underlying behaviour of the volcanic system and therefore require close monitoring. Thermal infrared cameras are an effective tool for imaging Vulcanian explosion plumes since they capture detailed temperature information, and can reveal the internal dynamics of the plume-forming explosions. High spatial resolution thermal images of 200 small to moderate sized Vulcanian explosions from the summit crater of Volcán de Colima, Mexico, recorded between 2006 and 2011, were analysed to distinguish different event types and develop an explosion classification scheme. Explosions display a broad spectrum of sizes and characteristics, ranging between two typical end-members: “large-impulsive” events producing rapidly ascending explosion plumes up to heights of 600-1600 m above the crater rim, and “small-diffusive” events with plumes restricted to heights < 600 m. Most explosion plumes comprise a steady “gas-thrust” feeder plume below a convecting plume front. Others, that lack sufficient kinetic energy, rise buoyantly throughout the explosion, with steady buoyant ascent velocities ranging from ~ 1 m s- 1 to ~ 29 m s- 1. A time-series of thermal imagery throughout the period 2006-2011 reveals a weak relationship between apparent plume temperatures and lava dome extrusion, with the highest explosion temperatures coinciding with the onset of dome growth in early 2007. Temporal variations in the source locations of explosions across the summit crater are also identified and appear to show a close relationship to the patterns of lava dome growth and thermal evolution, with explosion source locations associated with the highest temperature thermal features.
Instant Grainification: Real-Time Grain-Size Analysis from Digital Images in the Field
NASA Astrophysics Data System (ADS)
Rubin, D. M.; Chezar, H.
2007-12-01
Over the past few years, digital cameras and underwater microscopes have been developed to collect in-situ images of sand-sized bed sediment, and software has been developed to measure grain size from those digital images (Chezar and Rubin, 2004; Rubin, 2004; Rubin et al., 2006). Until now, all image processing and grain- size analysis was done back in the office where images were uploaded from cameras and processed on desktop computers. Computer hardware has become small and rugged enough to process images in the field, which for the first time allows real-time grain-size analysis of sand-sized bed sediment. We present such a system consisting of weatherproof tablet computer, open source image-processing software (autocorrelation code of Rubin, 2004, running under Octave and Cygwin), and digital camera with macro lens. Chezar, H., and Rubin, D., 2004, Underwater microscope system: U.S. Patent and Trademark Office, patent number 6,680,795, January 20, 2004. Rubin, D.M., 2004, A simple autocorrelation algorithm for determining grain size from digital images of sediment: Journal of Sedimentary Research, v. 74, p. 160-165. Rubin, D.M., Chezar, H., Harney, J.N., Topping, D.J., Melis, T.S., and Sherwood, C.R., 2006, Underwater microscope for measuring spatial and temporal changes in bed-sediment grain size: USGS Open-File Report 2006-1360.
Head circumference as a useful surrogate for intracranial volume in older adults.
Hshieh, Tammy T; Fox, Meaghan L; Kosar, Cyrus M; Cavallari, Michele; Guttmann, Charles R G; Alsop, David; Marcantonio, Edward R; Schmitt, Eva M; Jones, Richard N; Inouye, Sharon K
2016-01-01
Intracranial volume (ICV) has been proposed as a measure of maximum lifetime brain size. Accurate ICV measures require neuroimaging which is not always feasible for epidemiologic investigations. We examined head circumference as a useful surrogate for ICV in older adults. 99 older adults underwent Magnetic Resonance Imaging (MRI). ICV was measured by Statistical Parametric Mapping 8 (SPM8) software or Functional MRI of the Brain Software Library (FSL) extraction with manual editing, typically considered the gold standard. Head circumferences were determined using standardized tape measurement. We examined estimated correlation coefficients between head circumference and the two MRI-based ICV measurements. Head circumference and ICV by SPM8 were moderately correlated (overall r = 0.73, men r = 0.67, women r = 0.63). Head circumference and ICV by FSL were also moderately correlated (overall r = 0.69, men r = 0.63, women r = 0.49). Head circumference measurement was strongly correlated with MRI-derived ICV. Our study presents a simple method to approximate ICV among older patients, which may prove useful as a surrogate for cognitive reserve in large scale epidemiologic studies of cognitive outcomes. This study also suggests the stability of head circumference correlation with ICV throughout the lifespan.
Barisoni, Laura; Troost, Jonathan P; Nast, Cynthia; Bagnasco, Serena; Avila-Casado, Carmen; Hodgin, Jeffrey; Palmer, Matthew; Rosenberg, Avi; Gasim, Adil; Liensziewski, Chrysta; Merlino, Lino; Chien, Hui-Ping; Chang, Anthony; Meehan, Shane M; Gaut, Joseph; Song, Peter; Holzman, Lawrence; Gibson, Debbie; Kretzler, Matthias; Gillespie, Brenda W; Hewitt, Stephen M
2016-07-01
The multicenter Nephrotic Syndrome Study Network (NEPTUNE) digital pathology scoring system employs a novel and comprehensive methodology to document pathologic features from whole-slide images, immunofluorescence and ultrastructural digital images. To estimate inter- and intra-reader concordance of this descriptor-based approach, data from 12 pathologists (eight NEPTUNE and four non-NEPTUNE) with experience from training to 30 years were collected. A descriptor reference manual was generated and a webinar-based protocol for consensus/cross-training implemented. Intra-reader concordance for 51 glomerular descriptors was evaluated on jpeg images by seven NEPTUNE pathologists scoring 131 glomeruli three times (Tests I, II, and III), each test following a consensus webinar review. Inter-reader concordance of glomerular descriptors was evaluated in 315 glomeruli by all pathologists; interstitial fibrosis and tubular atrophy (244 cases, whole-slide images) and four ultrastructural podocyte descriptors (178 cases, jpeg images) were evaluated once by six and five pathologists, respectively. Cohen's kappa for inter-reader concordance for 48/51 glomerular descriptors with sufficient observations was moderate (0.40
Does Instructor's Image Size in Video Lectures Affect Learning Outcomes?
ERIC Educational Resources Information Center
Pi, Z.; Hong, J.; Yang, J.
2017-01-01
One of the most commonly used forms of video lectures is a combination of an instructor's image and accompanying lecture slides as a picture-in-picture. As the image size of the instructor varies significantly across video lectures, and so do the learning outcomes associated with this technology, the influence of the instructor's image size should…
NASA Astrophysics Data System (ADS)
Zhu, C.; Kobayashi, H.; Kanaya, Y.; Saito, M.
2017-12-01
Pollutants emitted from wildfires in boreal Eurasia can be transported to the Arctic, and their subsequent deposition could accelerate global warming. The Moderate Resolution Imaging Spectroradiometer (MODIS) MCD64A1 burned area product is used widely for global mapping of burned areas in conjunction with products such as the Global Fire Emission Database version 4, which can estimate pollutant emissions. However, uncertainties due to the "moderate resolution" (500 m) characteristic of the MODIS sensor could be introduced. Here, we present a size-dependent validation of MCD64A1 with reference to higher resolution (better than 30 m) satellite products (Landsat 7 ETM+, RapidEye, WorldView-2, and GeoEye-1) for six ecotypes over 12 regions of boreal Eurasia. We considered the 2012 boreal Eurasia burning season when severe wildfires occurred and when Arctic sea ice extent was historically low. Among the six ecotypes, we found MCD64A1 burned areas comprised only 13% of the reference products in croplands because of inadequate detection of small fires (<100 ha). Our results indicate that over all ecotypes, the actual burned area in boreal Eurasia (15,256 km2) could have been 16% greater than suggested by MCD64A1 (13,187 km2). We suggest applying correction factors of 0.5-8.2 when using emission rates based on MCD64A1 burned areas in chemistry and climate models of the studied regions. This implies the effects of wildfire emissions in boreal Eurasia on Arctic warming could be greater than currently estimated.
Dust Studies in DIII-D and TEXTOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudakov, D L; Litnovsky, A; West, W P
2009-02-17
Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicron sized dust is routinely observed using Mie scattering from a Nd:Yag laser. The source is strongly correlated with the presence of Type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Direct heating of the dust particles by the neutralmore » beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust. Large flakes or debris falling into the plasma may result in a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micron-size dust in plasma discharges. In DIII-D, a sample holder filled with {approx}30 mg of dust is introduced in the lower divertor and exposed to high-power ELMing H-mode discharges with strike points swept across the divertor floor. After a brief exposure ({approx}0.1 s) at the outer strike point, part of the dust is injected into the plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase of the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off layer 0-2 cm radially outside of the last closed flux surface in discharges heated with neutral beam injection (NBI) power of 1.4 MW. At the given configuration of the launch, the dust did not penetrate the core plasma and only moderately perturbed the edge plasma, as evidenced by an increase of the edge carbon content.« less
Dust studies in DIII-D and TEXTOR
NASA Astrophysics Data System (ADS)
Rudakov, D. L.; Litnovsky, A.; West, W. P.; Yu, J. H.; Boedo, J. A.; Bray, B. D.; Brezinsek, S.; Brooks, N. H.; Fenstermacher, M. E.; Groth, M.; Hollmann, E. M.; Huber, A.; Hyatt, A. W.; Krasheninnikov, S. I.; Lasnier, C. J.; McLean, A. G.; Moyer, R. A.; Pigarov, A. Yu.; Philipps, V.; Pospieszczyk, A.; Smirnov, R. D.; Sharpe, J. P.; Solomon, W. M.; Watkins, J. G.; Wong, C. P. C.
2009-08-01
Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicrometre sized dust is routinely observed using Mie scattering from a Nd : Yag laser. The source is strongly correlated with the presence of type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Heating of the dust particles by the neutral beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust; on the other hand, large flakes or debris falling into the plasma may induce a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micrometre-size particles into plasma discharges. In DIII-D, a sample holder filled with 30-40 mg of dust is inserted in the lower divertor and exposed, via sweeping of the strike points, to the diverted plasma flux of high-power ELMing H-mode discharges. After a brief dwell (~0.1 s) of the outer strike point on the sample holder, part of the dust penetrates into the core plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase in the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off-layer 0-2 cm radially outside of the last closed flux surface in discharges heated with 1.4 MW of NBI. Launched in this configuration, the dust perturbed the edge plasma, as evidenced by a moderate increase in the edge carbon content, but did not penetrate into the core plasma.
Particle Morphology Analysis of Biomass Material Based on Improved Image Processing Method
Lu, Zhaolin
2017-01-01
Particle morphology, including size and shape, is an important factor that significantly influences the physical and chemical properties of biomass material. Based on image processing technology, a method was developed to process sample images, measure particle dimensions, and analyse the particle size and shape distributions of knife-milled wheat straw, which had been preclassified into five nominal size groups using mechanical sieving approach. Considering the great variation of particle size from micrometer to millimeter, the powders greater than 250 μm were photographed by a flatbed scanner without zoom function, and the others were photographed using a scanning electron microscopy (SEM) with high-image resolution. Actual imaging tests confirmed the excellent effect of backscattered electron (BSE) imaging mode of SEM. Particle aggregation is an important factor that affects the recognition accuracy of the image processing method. In sample preparation, the singulated arrangement and ultrasonic dispersion methods were used to separate powders into particles that were larger and smaller than the nominal size of 250 μm. In addition, an image segmentation algorithm based on particle geometrical information was proposed to recognise the finer clustered powders. Experimental results demonstrated that the improved image processing method was suitable to analyse the particle size and shape distributions of ground biomass materials and solve the size inconsistencies in sieving analysis. PMID:28298925
Diurnal, Seasonal, and Interannual Variations of Cloud Properties Derived for CERES From Imager Data
NASA Technical Reports Server (NTRS)
Minnis, Patrick; Young, David F.; Sun-Mack, Sunny; Trepte, Qing Z.; Chen, Yan; Brown, Richard R.; Gibson, Sharon; Heck, Patrick W.
2004-01-01
Simultaneous measurement of the radiation and cloud fields on a global basis is a key component in the effort to understand and model the interaction between clouds and radiation at the top of the atmosphere, at the surface, and within the atmosphere. The NASA Clouds and Earth s Radiant Energy System (CERES) Project, begun in 1998, is meeting this need. Broadband shortwave (SW) and longwave radiance measurements taken by the CERES scanners at resolutions between 10 and 20 km on the Tropical Rainfall Measuring Mission (TRMM), Terra, and Aqua satellites are matched to simultaneous retrievals of cloud height, phase, particle size, water path, and optical depth OD from the TRMM Visible Infrared Scanner (VIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua. Besides aiding the interpretation of the broadband radiances, the CERES cloud properties are valuable for understanding cloud variations at a variety of scales. In this paper, the resulting CERES cloud data taken to date are averaged at several temporal scales to examine the temporal and spatial variability of the cloud properties on a global scale at a 1 resolution.
Leung, T K; Lin, J M; Chu, C L; Wu, Y S; Chao, Y J
2012-12-01
Most applications of gradual pressure-decline compressing stockings (GPDCS) are used in the United States and Western European countries, with over a decade of clinical experiments. Up to know, there is no standard establishment of gradual pressure-decline compressing stockings for Asian patients with venous insufficiency and varicose vein formations. We collected data on volunteer candidates of varicose vein for general measurements and assessments and magnetic resonance imaging (MRI) by non-contrast enhanced MRV techniques, and for post processing data analysis. Clinical use of GPCDS provide a mild to moderate improvement in the varicose vein conditions of patients with deep venous insufficiency by improving their deep vein circulation, by general measurements; recording major symptoms and complaint; comfort and stretching/flexibility to the candidates after using GPDCS; and area changes/flow velocity changes/available hemoglobin changes in deep veins monitored by MRI. The benefits and data collected in these results may help in developing compression stockings standards in Taiwanese and Asian countries, and to establishing criterias for product sizes, compression levels, and related parameters.
Constraining Aerosol Properties with the Spectrally-Resolved Phase Function of Pluto's Hazes
NASA Astrophysics Data System (ADS)
Parker, A. H.; Howett, C.; Olkin, C.; Protopapa, S.; Grundy, W. M.; Gladstone, R.; Young, L. A.; Horst, S. M.; Weaver, H. A., Jr.; Moore, J. M.; Ennico Smith, K.; Stern, A.
2017-12-01
The Multi-spectral Visible Imaging Camera (MVIC) and Lisa Hardaway Infrared Mapping Spectrometer (LEISA) aboard New Horizons imaged Pluto at high phase throughout departure from the system in July of 2015. The repeated MVIC color scans captured the phase behavior of Pluto's atmospheric hazes through phase angles of 165.0 to 169.5 degrees in four bandpasses in the visible and NIR. A spatially-resolved departure LEISA scan delivered moderate SNR NIR spectra of the hazes over wavelengths from 1.25 - 2.5 microns. Here we present our analysis of the departure MVIC and LEISA data, extracting high precision color phase curves of the hazes using the most up-to-date radiometric calibration and NIR gain drift corrections. We interpret these phase curves and spectra using Mie theory to constrain the size and composition of haze particles, with results indicating broad similarity to Titan aerosol analogues ("tholins"). Finally, we will explore the implications of the nature of these haze particles for the evolution of Pluto's surface as they settle out onto it over time.
Levin, Harvey S.; Wilde, Elisabeth A.; Chu, Zili; Yallampalli, Ragini; Hanten, Gerri R.; Li, Xiaoqi; Chia, Jon; Vasquez, Carmen; Hunter, Jill V.
2008-01-01
Objective To investigate the relation of white matter integrity using diffusion tensor imaging (DTI) to cognitive and functional outcome of moderate to severe traumatic brain injury (TBI) in children. Design Prospective observational study of children who had sustained moderate to severe TBI and a comparison group of children who had sustained orthopedic injury (OI). Participants Thirty-two children who had sustained moderate to severe TBI and 36 children with OI were studied. Methods Fiber tracking analysis of DTI acquired at 3-month postinjury and assessment of global outcome and cognitive function within 2 weeks of brain imaging. Global outcome was assessed using the Glasgow Outcome Scale and the Flanker task was used to measure cognitive processing speed and resistance to interference. Results Fractional anisotropy and apparent diffusion coefficient values differentiated the groups and both cognitive and functional outcome measures were related to the DTI findings. Dissociations were present wherein the relation of Fractional anisotropy to cognitive performance differed between the TBI and OI groups. A DTI composite measure of white matter integrity was related to global outcome in the children with TBI. Conclusions DTI is sensitive to white matter injury at 3 months following moderate to severe TBI in children, including brain regions that appear normal on conventional magnetic resonance imaging. DTI measures reflecting diffusion of water parallel and perpendicular to white matter tracts as calculated by fiber tracking analysis are related to global outcome, cognitive processing speed, and speed of resolving interference in children with moderate to severe TBI. Longitudinal data are needed to determine whether these relations between DTI and neurobehavioral outcome of TBI in children persist at longer follow-up intervals. PMID:18650764
NASA Astrophysics Data System (ADS)
Kassianov, E.; Pekour, M. S.; Flynn, C. J.; Berg, L. K.; Beranek, J.; Zelenyuk, A.; Zhao, C.; Leung, L. R.; Ma, P. L.; Riihimaki, L.; Fast, J. D.; Barnard, J.; Hallar, G. G.; McCubbin, I.; Eloranta, E. W.; McComiskey, A. C.; Rasch, P. J.
2017-12-01
Understanding the effects of dust on the regional and global climate requires detailed information on particle size distributions and their changes with distance from the source. Awareness is now growing about the tendency of the dust coarse mode with moderate ( 3.5 µm) volume median diameter (VMD) to be rather insensitive to complex removal processes associated with long-range transport of dust from the main sources. Our study, with a focus on the transpacific transport of dust, demonstrates that the impact of coarse mode aerosol (VMD 3µm) is well defined at the high-elevation mountain-top Storm Peak Laboratory (SPL, about 3.2 km MSL) and nearby Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) during March 2011. Significant amounts of coarse mode aerosol are also found at the nearest Aerosol Robotic Network (AERONET) site. Outputs from the high-resolution Weather Research and Forecasting (WRF) Model coupled with chemistry (WRF-Chem) show that the major dust event is likely associated with transpacific transport of Asian and African plumes. Satellite data, including the Moderate Resolution Imaging Spectroradiometer (MODIS) and Multiangle Imaging SpectroRadiometer (MISR) aerosol optical depth (AOD) and plume height from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) lidar data provide the observational support of the WRF-Chem simulations. Our study complements previous findings by indicating that the quasi-static nature of the coarse mode appears to be a reasonable approximation for Asian and African dust despite expected frequent orographic precipitation over mountainous regions in the western United States.
Waif goodbye! Average-size female models promote positive body image and appeal to consumers.
Diedrichs, Phillippa C; Lee, Christina
2011-10-01
Despite consensus that exposure to media images of thin fashion models is associated with poor body image and disordered eating behaviours, few attempts have been made to enact change in the media. This study sought to investigate an effective alternative to current media imagery, by exploring the advertising effectiveness of average-size female fashion models, and their impact on the body image of both women and men. A sample of 171 women and 120 men were assigned to one of three advertisement conditions: no models, thin models and average-size models. Women and men rated average-size models as equally effective in advertisements as thin and no models. For women with average and high levels of internalisation of cultural beauty ideals, exposure to average-size female models was associated with a significantly more positive body image state in comparison to exposure to thin models and no models. For men reporting high levels of internalisation, exposure to average-size models was also associated with a more positive body image state in comparison to viewing thin models. These findings suggest that average-size female models can promote positive body image and appeal to consumers.
Sun, Maryellen R M; Wagner, Andrew A; San Francisco, Ignacio F; Brook, Alexander; Kavoussi, Louis; Russo, Paul; Steele, Graeme; Viterbo, Rosalia; Pedrosa, Ivan
2012-03-01
This study aimed to evaluate the need for intraoperative ultrasound (IOUS) and recommendation for surgical approach in the resection of renal tumors through a survey of practicing urologists, with correlation to tumor imaging features and urologist practice pattern. An institutional review board-approved retrospective review, compliant with the Health Insurance Portability and Accountability Act, of 44 renal tumors that underwent laparoscopic partial nephrectomy at the study institution was performed. The numeric component of the RENAL nephrometry score (radius [diameter], % exophytic, nearness [to collecting system/renal sinus], location) was calculated for each case using preoperative computed tomography/magnetic resonance imaging. Five anonymized images of each tumor were presented to 4 academic urologists with varying practice patterns. Reviewers independently scored each case for its need for IOUS, for recommendation of a surgical technique, and for the difficulty of the proposed surgery. The RENAL scores were as follows: RENAL 1 (low complexity, score 4-6; n = 19); RENAL 2 (moderate complexity, score 7-9; n = 23); RENAL 3 (high complexity, score 10-12; n = 2). The only RENAL score component significantly influencing need for IOUS was percentage exophytic (P = 0.00002). There was an inverse relationship between normalized and averaged need for IOUS and percentage exophytic (P < 0.0001). The predominant influence for recommendation of surgical method was the reviewer him/herself, with each reviewer's recommendations closely matching his/her practice pattern. Size and percentage exophytic represented the only tumor features significantly (P = 0.03) influencing surgical recommendation. There was a significant difference in the perceived need for IOUS and surgical recommendation when 4 academic urologists reviewed a series of renal masses requiring resection. Percentage exophytic correlated inversely with need for IOUS. Urologist's practice pattern and tumor size and percentage exophytic were most predictive of surgical recommendation.
Posse, Stefan; Ackley, Elena; Mutihac, Radu; Rick, Jochen; Shane, Matthew; Murray-Krezan, Cristina; Zaitsev, Maxim; Speck, Oliver
2012-01-01
In this study, a new approach to high-speed fMRI using multi-slab echo-volumar imaging (EVI) is developed that minimizes geometrical image distortion and spatial blurring, and enables nonaliased sampling of physiological signal fluctuation to increase BOLD sensitivity compared to conventional echo-planar imaging (EPI). Real-time fMRI using whole brain 4-slab EVI with 286 ms temporal resolution (4 mm isotropic voxel size) and partial brain 2-slab EVI with 136 ms temporal resolution (4×4×6 mm3 voxel size) was performed on a clinical 3 Tesla MRI scanner equipped with 12-channel head coil. Four-slab EVI of visual and motor tasks significantly increased mean (visual: 96%, motor: 66%) and maximum t-score (visual: 263%, motor: 124%) and mean (visual: 59%, motor: 131%) and maximum (visual: 29%, motor: 67%) BOLD signal amplitude compared with EPI. Time domain moving average filtering (2 s width) to suppress physiological noise from cardiac and respiratory fluctuations further improved mean (visual: 196%, motor: 140%) and maximum (visual: 384%, motor: 200%) t-scores and increased extents of activation (visual: 73%, motor: 70%) compared to EPI. Similar sensitivity enhancement, which is attributed to high sampling rate at only moderately reduced temporal signal-to-noise ratio (mean: − 52%) and longer sampling of the BOLD effect in the echo-time domain compared to EPI, was measured in auditory cortex. Two-slab EVI further improved temporal resolution for measuring task-related activation and enabled mapping of five major resting state networks (RSNs) in individual subjects in 5 min scans. The bilateral sensorimotor, the default mode and the occipital RSNs were detectable in time frames as short as 75 s. In conclusion, the high sampling rate of real-time multi-slab EVI significantly improves sensitivity for studying the temporal dynamics of hemodynamic responses and for characterizing functional networks at high field strength in short measurement times. PMID:22398395
ERIC Educational Resources Information Center
Mechling, Linda C.; Youhouse, Iva R.
2012-01-01
This investigation compared the ability of students with disabilities to complete fine motor tasks when presented with video models on a small personal digital assistant (PDA) screen and a traditional computer laptop screen. Two groups of elementary age students participated in the study: four with moderate intellectual disabilities (Moderate ID),…
Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin; Kamburoğlu, Kıvanç
To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax(®) 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm(3) voxel size), high-resolution mode (0.150 mm(3) voxel size) and low-resolution mode (0.400 mm(3) voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general, higher Az values were obtained for composite restorations than for amalgam restorations for all observers. For Observer 1, Az values for composite restorations were statistically significantly higher than those of amalgam restorations for MacBook and iPhone (Apple Inc., Cupertino, CA) assessments (p = 0.002 and p = 0.048, respectively). Higher Az values were observed with medical monitors when used with dedicated software compared to other display types which performed similarly in the diagnosis of recurrent caries under restorations. In addition, observers performed better in detection of recurrent caries when assessing composite restorations than amalgams.
Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin
2016-01-01
Objectives: To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Methods: Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax® 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. Results: We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm3 voxel size), high-resolution mode (0.150 mm3 voxel size) and low-resolution mode (0.400 mm3 voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general, higher Az values were obtained for composite restorations than for amalgam restorations for all observers. For Observer 1, Az values for composite restorations were statistically significantly higher than those of amalgam restorations for MacBook and iPhone (Apple Inc., Cupertino, CA) assessments (p = 0.002 and p = 0.048, respectively). Conclusions: Higher Az values were observed with medical monitors when used with dedicated software compared to other display types which performed similarly in the diagnosis of recurrent caries under restorations. In addition, observers performed better in detection of recurrent caries when assessing composite restorations than amalgams. PMID:27319604
Image analysis of representative food structures: application of the bootstrap method.
Ramírez, Cristian; Germain, Juan C; Aguilera, José M
2009-08-01
Images (for example, photomicrographs) are routinely used as qualitative evidence of the microstructure of foods. In quantitative image analysis it is important to estimate the area (or volume) to be sampled, the field of view, and the resolution. The bootstrap method is proposed to estimate the size of the sampling area as a function of the coefficient of variation (CV(Bn)) and standard error (SE(Bn)) of the bootstrap taking sub-areas of different sizes. The bootstrap method was applied to simulated and real structures (apple tissue). For simulated structures, 10 computer-generated images were constructed containing 225 black circles (elements) and different coefficient of variation (CV(image)). For apple tissue, 8 images of apple tissue containing cellular cavities with different CV(image) were analyzed. Results confirmed that for simulated and real structures, increasing the size of the sampling area decreased the CV(Bn) and SE(Bn). Furthermore, there was a linear relationship between the CV(image) and CV(Bn) (.) For example, to obtain a CV(Bn) = 0.10 in an image with CV(image) = 0.60, a sampling area of 400 x 400 pixels (11% of whole image) was required, whereas if CV(image) = 1.46, a sampling area of 1000 x 100 pixels (69% of whole image) became necessary. This suggests that a large-size dispersion of element sizes in an image requires increasingly larger sampling areas or a larger number of images.
NASA Astrophysics Data System (ADS)
Zhang, Wei; Wang, Yanan; Zhu, Zhenhao; Su, Jinhui
2018-05-01
A focused plenoptic camera can effectively transform angular and spatial information to yield a refocused rendered image with high resolution. However, choosing a proper patch size poses a significant problem for the image-rendering algorithm. By using a spatial frequency response measurement, a method to obtain a suitable patch size is presented. By evaluating the spatial frequency response curves, the optimized patch size can be obtained quickly and easily. Moreover, the range of depth over which images can be rendered without artifacts can be estimated. Experiments show that the results of the image rendered based on frequency response measurement are in accordance with the theoretical calculation, which indicates that this is an effective way to determine the patch size. This study may provide support to light-field image rendering.
Quantitative endoscopy: initial accuracy measurements.
Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P
2000-02-01
The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.
Perceived face size in healthy adults.
D'Amour, Sarah; Harris, Laurence R
2017-01-01
Perceptual body size distortions have traditionally been studied using subjective, qualitative measures that assess only one type of body representation-the conscious body image. Previous research on perceived body size has typically focused on measuring distortions of the entire body and has tended to overlook the face. Here, we present a novel psychophysical method for determining perceived body size that taps into implicit body representation. Using a two-alternative forced choice (2AFC), participants were sequentially shown two life-size images of their own face, viewed upright, upside down, or tilted 90°. In one interval, the width or length dimension was varied, while the other interval contained an undistorted image. Participants reported which image most closely matched their own face. An adaptive staircase adjusted the distorted image to hone in on the image that was equally likely to be judged as matching their perceived face as the accurate image. When viewed upright or upside down, face width was overestimated and length underestimated, whereas perception was accurate for the on-side views. These results provide the first psychophysically robust measurements of how accurately healthy participants perceive the size of their face, revealing distortions of the implicit body representation independent of the conscious body image.
WE-H-207A-05: Spatial Co-Localization of F-18 NaF Vs. F-18 FDG Defined Disease Volumes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferjancic, P; Harmon, S; Jeraj, R
Purpose: Both [F-18]NaF and [F-18]FDG show promise for quantitative PET/CT assessment in metastatic prostate cancer to bone. Broad agreement between the tracers has been shown but voxel-wise correspondence has not been explored in depth. This study evaluates the spatial co-localization of [F-18]NaF PET and [F-18]FDG PET in bone lesions. Methods: Seventy-three lesion contours were identified in six patients receiving dynamic NaF PET/CT and FDG PET/CT scans two hours apart using identical fields-of-view. Tracer uptake (SUV) reflecting 60 minutes post-injection was modeled from kinetic parameters. Lesions were segmented by a physician separately on NaF PET and FDG PET. PET images weremore » rigidly aligned using skeletal references on CT images. Lesion size, degree of overlap, voxel-wise tracer uptake values (SUV), and CT density distributions were compared using Dice coefficient, Positive Predictive Value (PPV), and Spearman rank correlation tests. Results: Across all patients, 42 lesions were identified on NaF PET (median 1.4 cm{sup 3}, range <1–204 cm{sup 3}) compared to 31 using FDG PET (median 1.8 cm{sup 3}, range <1–244 cm{sup 3}). Spatial cooccurrence was found in 25 lesion pairs. Lesions on NaF PET had PPV of 0.91 and on FDG a PPV of 0.65. Overall, NaF-defined lesions were 47% (±24%) larger by volume with moderate overlap to FDG, resulting in mean Dice coefficient of 34% (±22%). In areas of overlap, voxel-wise correlation of NaF and FDG SUV was moderate (ρ=0.56). Expanding to regions of non-spatial overlap, voxels contained in FDG-only contours were almost exclusively low HU (median 118), compared to dense regions of NaF-only voxels (median 250). In sclerotic sub-volumes (HU > 300) NaF-defined contours encompassed 83% of total FDG volume. Conclusion: Moderate voxel-wise correlation of FDG and NaF PET/CT uptake was observed. Spatial discrepancies in FDG and NaF PET/CT imaging of boney metastases could be influenced by poor sensitivity of FDG PET/CT in sclerotic regions. Funded by Prostate Cancer Foundation.« less
Development of a Near-Real Time Hail Damage Swath Identification Algorithm for Vegetation
NASA Technical Reports Server (NTRS)
Bell, Jordan R.; Molthan, Andrew L.; Schultz, Lori A.; McGrath, Kevin M.; Burks, Jason E.
2015-01-01
The Midwest is home to one of the world's largest agricultural growing regions. Between the time period of late May through early September, and with irrigation and seasonal rainfall these crops are able to reach their full maturity. Using moderate to high resolution remote sensors, the monitoring of the vegetation can be achieved using the red and near-infrared wavelengths. These wavelengths allow for the calculation of vegetation indices, such as Normalized Difference Vegetation Index (NDVI). The vegetation growth and greenness, in this region, grows and evolves uniformly as the growing season progresses. However one of the biggest threats to Midwest vegetation during the time period is thunderstorms that bring large hail and damaging winds. Hail and wind damage to crops can be very expensive to crop growers and, damage can be spread over long swaths associated with the tracks of the damaging storms. Damage to the vegetation can be apparent in remotely sensed imagery and is visible from space after storms slightly damage the crops, allowing for changes to occur slowly over time as the crops wilt or more readily apparent if the storms strip material from the crops or destroy them completely. Previous work on identifying these hail damage swaths used manual interpretation by the way of moderate and higher resolution satellite imagery. With the development of an automated and near-real time hail swath damage identification algorithm, detection can be improved, and more damage indicators be created in a faster and more efficient way. The automated detection of hail damage swaths will examine short-term, large changes in the vegetation by differencing near-real time eight day NDVI composites and comparing them to post storm imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) aboard Terra and Aqua and Visible Infrared Imaging Radiometer Suite (VIIRS) aboard Suomi NPP. In addition land surface temperatures from these instruments will be examined as for hail damage swath identification. Initial validation of the automated algorithm is based upon Storm Prediction Center storm reports but also the National Severe Storm Laboratory (NSSL) Maximum Estimated Size Hail (MESH) product. Opportunities for future work are also shown, with focus on expansion of this algorithm with pixel-based image classification techniques for tracking surface changes as a result of severe weather.
Newsome, Mary R; Scheibel, Randall S; Chu, Zili; Hunter, Jill V; Li, Xiaoqi; Wilde, Elisabeth A; Lu, Hanzhang; Wang, Zhiyue J; Lin, Xiaodi; Steinberg, Joel L; Vasquez, Ana C; Cook, Lori; Levin, Harvey S
2012-05-01
Alterations in cerebrovascular function are evident acutely in moderate to severe traumatic brain injury (TBI), although less is known about their chronic effects. Adolescent and adult patients with moderate to severe TBI have been reported to demonstrate diffuse activation throughout the brain during functional magnetic resonance imaging (fMRI). Because fMRI is a measure related to blood flow, it is possible that any deficits in blood flow may alter activation. An arterial spin labeling (ASL) perfusion sequence was performed on seven adolescents with chronic moderate to severe TBI and seven typically developing (TD) adolescents during the same session in which they had performed a social cognition task during fMRI. In the TD group, prefrontal CBF was positively related to prefrontal activation and negatively related to non-prefrontal, posterior, brain activation. This relationship was not seen in the TBI group, who demonstrated a greater positive relationship between prefrontal CBF and non-prefrontal activation than the TD group. An analysis of CBF data independent of fMRI showed reduced CBF in the right non-prefrontal region (p<.055) in the TBI group. To understand any role reduced CBF may play in diffuse extra-activation, we then related the right non-prefrontal CBF to activation. CBF in the right non-prefrontal region in the TD group was positively associated with prefrontal activation, suggesting an interactive role of non-prefrontal and prefrontal blood flow throughout the right hemisphere in healthy brains. However, the TBI group demonstrated a positive association with activation constrained to the right non-prefrontal region. These data suggest a relationship between impaired non-prefrontal CBF and the presence of non-prefrontal extra-activation, where the region with more limited blood flow is associated with activation limited to that region. In a secondary analysis, pathology associated with hyperintensities on T2-weighted FLAIR imaging over the whole brain was related to whole brain activation, revealing a negative relationship between lesion volume and frontal activation, and a positive relationship between lesion volume and posterior activation. These preliminary data, albeit collected with small sample sizes, suggest that reduced non-prefrontal CBF, and possibly pathological tissue associated with T2-hyperintensities, may provide contributions to the diffuse, primarily posterior extra-activation observed in adolescents following moderate to severe TBI. Published by Elsevier Ltd.
Automatic Temporal Tracking of Supra-Glacial Lakes
NASA Astrophysics Data System (ADS)
Liang, Y.; Lv, Q.; Gallaher, D. W.; Fanning, D.
2010-12-01
During the recent years, supra-glacial lakes in Greenland have attracted extensive global attention as they potentially play an important role in glacier movement, sea level rise, and climate change. Previous works focused on classification methods and individual cloud-free satellite images, which have limited capabilities in terms of tracking changes of lakes over time. The challenges of tracking supra-glacial lakes automatically include (1) massive amount of satellite images with diverse qualities and frequent cloud coverage, and (2) diversity and dynamics of large number of supra-glacial lakes on the Greenland ice sheet. In this study, we develop an innovative method to automatically track supra-glacial lakes temporally using the Moderate Resolution Imaging Spectroradiometer (MODIS) time-series data. The method works for both cloudy and cloud-free data and is unsupervised, i.e., no manual identification is required. After selecting the highest-quality image within each time interval, our method automatically detects supra-glacial lakes in individual images, using adaptive thresholding to handle diverse image qualities. We then track lakes across time series of images as lakes appear, change in size, and disappear. Using multi-year MODIS data during melting season, we demonstrate that this new method can detect and track supra-glacial lakes in both space and time with 95% accuracy. Attached figure shows an example of the current result. Detailed analysis of the temporal variation of detected lakes will be presented. (a) One of our experimental data. The Investigated region is centered at Jakobshavn Isbrae glacier in west Greenland. (b) Enlarged view of part of ice sheet. It is partially cloudy and with supra-glacial lakes on it. Lakes are shown as dark spots. (c) Current result. Red spots are detected lakes.
False Color Mosaic of Jupiter's Belt-Zone Boundary
NASA Technical Reports Server (NTRS)
1997-01-01
False-color mosaic of a belt-zone boundary near Jupiter's equator. The images that make up the four quadrants of this mosaic were taken within a few minutes of each other. Light at each of Galileo's three near-infrared wavelengths is displayed here mapped to the visible colors red, green, and blue. Light at 886 nanometers, strongly absorbed by atmospheric methane and scattered from clouds high in the atmosphere, is shown in red. Light at 732 nanometers, moderately absorbed by atmospheric methane, is shown in green. Light at 757 nanometers, scattered mostly from Jupiter's lower visible cloud deck, is shown in blue. The lower cloud deck appears bluish white, while the higher layer appears pinkish. The holes in the upper layer and their relationships to features in the lower cloud deck can be studied in the lower half of the mosaic. Galileo is the first spacecraft to image different layers in Jupiter's atmosphere.
North is at the top. The mosaic covers latitudes -13 to +3 degrees and is centered at longitude 282 degrees West. The smallest resolved features are tens of kilometers in size. These images were taken on November 5th, 1996, at a range of 1.2 million kilometers by the Solid State Imaging system aboard NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoFractal scaling of apparent soil moisture estimated from vertical planes of Vertisol pit images
NASA Astrophysics Data System (ADS)
Cumbrera, Ramiro; Tarquis, Ana M.; Gascó, Gabriel; Millán, Humberto
2012-07-01
SummaryImage analysis could be a useful tool for investigating the spatial patterns of apparent soil moisture at multiple resolutions. The objectives of the present work were (i) to define apparent soil moisture patterns from vertical planes of Vertisol pit images and (ii) to describe the scaling of apparent soil moisture distribution using fractal parameters. Twelve soil pits (0.70 m long × 0.60 m width × 0.30 m depth) were excavated on a bare Mazic Pellic Vertisol. Six of them were excavated in April/2011 and six pits were established in May/2011 after 3 days of a moderate rainfall event. Digital photographs were taken from each Vertisol pit using a Kodak™ digital camera. The mean image size was 1600 × 945 pixels with one physical pixel ≈373 μm of the photographed soil pit. Each soil image was analyzed using two fractal scaling exponents, box counting (capacity) dimension (DBC) and interface fractal dimension (Di), and three prefractal scaling coefficients, the total number of boxes intercepting the foreground pattern at a unit scale (A), fractal lacunarity at the unit scale (Λ1) and Shannon entropy at the unit scale (S1). All the scaling parameters identified significant differences between both sets of spatial patterns. Fractal lacunarity was the best discriminator between apparent soil moisture patterns. Soil image interpretation with fractal exponents and prefractal coefficients can be incorporated within a site-specific agriculture toolbox. While fractal exponents convey information on space filling characteristics of the pattern, prefractal coefficients represent the investigated soil property as seen through a higher resolution microscope. In spite of some computational and practical limitations, image analysis of apparent soil moisture patterns could be used in connection with traditional soil moisture sampling, which always renders punctual estimates.
IIPImage: Large-image visualization
NASA Astrophysics Data System (ADS)
Pillay, Ruven
2014-08-01
IIPImage is an advanced high-performance feature-rich image server system that enables online access to full resolution floating point (as well as other bit depth) images at terabyte scales. Paired with the VisiOmatic (ascl:1408.010) celestial image viewer, the system can comfortably handle gigapixel size images as well as advanced image features such as both 8, 16 and 32 bit depths, CIELAB colorimetric images and scientific imagery such as multispectral images. Streaming is tile-based, which enables viewing, navigating and zooming in real-time around gigapixel size images. Source images can be in either TIFF or JPEG2000 format. Whole images or regions within images can also be rapidly and dynamically resized and exported by the server from a single source image without the need to store multiple files in various sizes.
Grid-enhanced X-ray coded aperture microscopy with polycapillary optics
Sowa, Katarzyna M.; Last, Arndt; Korecki, Paweł
2017-01-01
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10–100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imaging with both synchrotrons and X-ray tubes. Recent studies have shown that the internal microstructure of such an optics can be used as a coded aperture that encodes high-resolution information about objects located inside the focal spot. However, further improvements to this variant of X-ray microscopy will require the challenging fabrication of tailored devices with a well-defined capillary microstructure. Here, we show that submicron coded aperture microscopy can be realized using a periodic grid that is placed at the output surface of a polycapillary optics. Grid-enhanced X-ray coded aperture microscopy with polycapillary optics does not rely on the specific microstructure of the optics but rather takes advantage only of its focusing properties. Hence, submicron X-ray imaging can be realized with standard polycapillary devices and existing set-ups for micro X-ray fluorescence spectroscopy. PMID:28322316
Grid-enhanced X-ray coded aperture microscopy with polycapillary optics.
Sowa, Katarzyna M; Last, Arndt; Korecki, Paweł
2017-03-21
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imaging with both synchrotrons and X-ray tubes. Recent studies have shown that the internal microstructure of such an optics can be used as a coded aperture that encodes high-resolution information about objects located inside the focal spot. However, further improvements to this variant of X-ray microscopy will require the challenging fabrication of tailored devices with a well-defined capillary microstructure. Here, we show that submicron coded aperture microscopy can be realized using a periodic grid that is placed at the output surface of a polycapillary optics. Grid-enhanced X-ray coded aperture microscopy with polycapillary optics does not rely on the specific microstructure of the optics but rather takes advantage only of its focusing properties. Hence, submicron X-ray imaging can be realized with standard polycapillary devices and existing set-ups for micro X-ray fluorescence spectroscopy.
NASA Technical Reports Server (NTRS)
1995-01-01
The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and Earth's Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies is outlined. Volume 3 details the advanced CERES methods for performing scene identification and inverting each CERES scanner radiance to a top-of-the-atmosphere (TOA) flux. CERES determines cloud fraction, height, phase, effective particle size, layering, and thickness from high-resolution, multispectral imager data. CERES derives cloud properties for each pixel of the Tropical Rainfall Measuring Mission (TRMM) visible and infrared scanner and the Earth Observing System (EOS) moderate-resolution imaging spectroradiometer. Cloud properties for each imager pixel are convolved with the CERES footprint point spread function to produce average cloud properties for each CERES scanner radiance. The mean cloud properties are used to determine an angular distribution model (ADM) to convert each CERES radiance to a TOA flux. The TOA fluxes are used in simple parameterization to derive surface radiative fluxes. This state-of-the-art cloud-radiation product will be used to substantially improve our understanding of the complex relationship between clouds and the radiation budget of the Earth-atmosphere system.
X-ray mosaic nanotomography of large microorganisms.
Mokso, R; Quaroni, L; Marone, F; Irvine, S; Vila-Comamala, J; Blanke, A; Stampanoni, M
2012-02-01
Full-field X-ray microscopy is a valuable tool for 3D observation of biological systems. In the soft X-ray domain organelles can be visualized in individual cells while hard X-ray microscopes excel in imaging of larger complex biological tissue. The field of view of these instruments is typically 10(3) times the spatial resolution. We exploit the assets of the hard X-ray sub-micrometer imaging and extend the standard approach by widening the effective field of view to match the size of the sample. We show that global tomography of biological systems exceeding several times the field of view is feasible also at the nanoscale with moderate radiation dose. We address the performance issues and limitations of the TOMCAT full-field microscope and more generally for Zernike phase contrast imaging. Two biologically relevant systems were investigated. The first being the largest known bacteria (Thiomargarita namibiensis), the second is a small myriapod species (Pauropoda sp.). Both examples illustrate the capacity of the unique, structured condenser based broad-band full-field microscope to access the 3D structural details of biological systems at the nanoscale while avoiding complicated sample preparation, or even keeping the sample environment close to the natural state. Copyright © 2012 Elsevier Inc. All rights reserved.
Practical implementation of Channelized Hotelling Observers: Effect of ROI size
Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H.
2017-01-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO’s performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO’s performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies. PMID:28943699
Wound size measurement of lower extremity ulcers using segmentation algorithms
NASA Astrophysics Data System (ADS)
Dadkhah, Arash; Pang, Xing; Solis, Elizabeth; Fang, Ruogu; Godavarty, Anuradha
2016-03-01
Lower extremity ulcers are one of the most common complications that not only affect many people around the world but also have huge impact on economy since a large amount of resources are spent for treatment and prevention of the diseases. Clinical studies have shown that reduction in the wound size of 40% within 4 weeks is an acceptable progress in the healing process. Quantification of the wound size plays a crucial role in assessing the extent of healing and determining the treatment process. To date, wound healing is visually inspected and the wound size is measured from surface images. The extent of wound healing internally may vary from the surface. A near-infrared (NIR) optical imaging approach has been developed for non-contact imaging of wounds internally and differentiating healing from non-healing wounds. Herein, quantitative wound size measurements from NIR and white light images are estimated using a graph cuts and region growing image segmentation algorithms. The extent of the wound healing from NIR imaging of lower extremity ulcers in diabetic subjects are quantified and compared across NIR and white light images. NIR imaging and wound size measurements can play a significant role in potentially predicting the extent of internal healing, thus allowing better treatment plans when implemented for periodic imaging in future.
Graham, Dan J; Sirard, John R; Neumark-Sztainer, Dianne
2011-02-01
To determine whether adolescent attitudes towards sports, exercise, and fitness predict moderate-to-vigorous physical activity 5 and 10 years later. A diverse group of 1902 adolescents participating in Project Eating and Activity in Teens, reported weekly moderate-to-vigorous physical activity and attitudes toward sports, exercise, and fitness in Eating and Activity in Teens-I (1998-99), Eating and Activity in Teens-II (2003-04), and Eating and Activity in Teens-III (2008-09). Mean moderate-to-vigorous physical activity was 6.4, 5.1, and 4.0 hours/week at baseline, 5-year, and 10-year follow-up, respectively. Attitudes toward sports, exercise, and fitness together predicted moderate-to-vigorous physical activity at 5 and 10 years. Among the predictors of 5- and 10-year moderate-to-vigorous physical activity, attitude's effect size, though modest, was comparable to the effect sizes for sports participation and body mass index. Adolescents with more-favorable attitudes toward sports, exercise, and fitness engaged in approximately 30%-40% more weekly moderate-to-vigorous physical activity at follow-up (2.1 hour/week at 5 years and 1.2 hour/week at 10 years) than those with less-favorable attitudes. Adolescents' exercise-related attitudes predict subsequent moderate-to-vigorous physical activity independent of baseline behavior suggesting that youth moderate-to-vigorous physical activity promotion efforts may provide long-term benefits by helping youth develop favorable exercise attitudes. Copyright © 2010 Elsevier Inc. All rights reserved.
Barnard, P.L.; Rubin, D.M.; Harney, J.; Mustain, N.
2007-01-01
This extensive field test of an autocorrelation technique for determining grain size from digital images was conducted using a digital bed-sediment camera, or 'beachball' camera. Using 205 sediment samples and >1200 images from a variety of beaches on the west coast of the US, grain size ranging from sand to granules was measured from field samples using both the autocorrelation technique developed by Rubin [Rubin, D.M., 2004. A simple autocorrelation algorithm for determining grain size from digital images of sediment. Journal of Sedimentary Research, 74(1): 160-165.] and traditional methods (i.e. settling tube analysis, sieving, and point counts). To test the accuracy of the digital-image grain size algorithm, we compared results with manual point counts of an extensive image data set in the Santa Barbara littoral cell. Grain sizes calculated using the autocorrelation algorithm were highly correlated with the point counts of the same images (r2 = 0.93; n = 79) and had an error of only 1%. Comparisons of calculated grain sizes and grain sizes measured from grab samples demonstrated that the autocorrelation technique works well on high-energy dissipative beaches with well-sorted sediment such as in the Pacific Northwest (r2 ??? 0.92; n = 115). On less dissipative, more poorly sorted beaches such as Ocean Beach in San Francisco, results were not as good (r2 ??? 0.70; n = 67; within 3% accuracy). Because the algorithm works well compared with point counts of the same image, the poorer correlation with grab samples must be a result of actual spatial and vertical variability of sediment in the field; closer agreement between grain size in the images and grain size of grab samples can be achieved by increasing the sampling volume of the images (taking more images, distributed over a volume comparable to that of a grab sample). In all field tests the autocorrelation method was able to predict the mean and median grain size with ???96% accuracy, which is more than adequate for the majority of sedimentological applications, especially considering that the autocorrelation technique is estimated to be at least 100 times faster than traditional methods.
Lin, Jonathan S; Hwang, Ken-Pin; Jackson, Edward F; Hazle, John D; Stafford, R Jason; Taylor, Brian A
2013-10-01
A k-means-based classification algorithm is investigated to assess suitability for rapidly separating and classifying fat/water spectral peaks from a fast chemical shift imaging technique for magnetic resonance temperature imaging. Algorithm testing is performed in simulated mathematical phantoms and agar gel phantoms containing mixed fat/water regions. Proton resonance frequencies (PRFs), apparent spin-spin relaxation (T2*) times, and T1-weighted (T1-W) amplitude values were calculated for each voxel using a single-peak autoregressive moving average (ARMA) signal model. These parameters were then used as criteria for k-means sorting, with the results used to determine PRF ranges of each chemical species cluster for further classification. To detect the presence of secondary chemical species, spectral parameters were recalculated when needed using a two-peak ARMA signal model during the subsequent classification steps. Mathematical phantom simulations involved the modulation of signal-to-noise ratios (SNR), maximum PRF shift (MPS) values, analysis window sizes, and frequency expansion factor sizes in order to characterize the algorithm performance across a variety of conditions. In agar, images were collected on a 1.5T clinical MR scanner using acquisition parameters close to simulation, and algorithm performance was assessed by comparing classification results to manually segmented maps of the fat/water regions. Performance was characterized quantitatively using the Dice Similarity Coefficient (DSC), sensitivity, and specificity. The simulated mathematical phantom experiments demonstrated good fat/water separation depending on conditions, specifically high SNR, moderate MPS value, small analysis window size, and low but nonzero frequency expansion factor size. Physical phantom results demonstrated good identification for both water (0.997 ± 0.001, 0.999 ± 0.001, and 0.986 ± 0.001 for DSC, sensitivity, and specificity, respectively) and fat (0.763 ± 0.006, 0.980 ± 0.004, and 0.941 ± 0.002 for DSC, sensitivity, and specificity, respectively). Temperature uncertainties, based on PRF uncertainties from a 5 × 5-voxel ROI, were 0.342 and 0.351°C for pure and mixed fat/water regions, respectively. Algorithm speed was tested using 25 × 25-voxel and whole image ROIs containing both fat and water, resulting in average processing times per acquisition of 2.00 ± 0.07 s and 146 ± 1 s, respectively, using uncompiled MATLAB scripts running on a shared CPU server with eight Intel Xeon(TM) E5640 quad-core processors (2.66 GHz, 12 MB cache) and 12 GB RAM. Results from both the mathematical and physical phantom suggest the k-means-based classification algorithm could be useful for rapid, dynamic imaging in an ROI for thermal interventions. Successful separation of fat/water information would aid in reducing errors from the nontemperature sensitive fat PRF, as well as potentially facilitate using fat as an internal reference for PRF shift thermometry when appropriate. Additionally, the T1-W or R2* signals may be used for monitoring temperature in surrounding adipose tissue.
Vegetation canopy structure from NASA EOS multiangle imaging
USDA-ARS?s Scientific Manuscript database
We used red band bidirectional reflectance data from the NASA Multiangle Imaging SpectroRadiometer (MISR) and the MODerate resolution Imaging Spectroradiometer (MODIS) mapped onto a 250 m grid in a multiangle approach to obtain estimates of woody plant fractional cover and crown height through adjus...
Kelly, Allison C; Vimalakanthan, Kiruthiha; Miller, Kathryn E
2014-09-01
The current study examined whether self-compassion, the tendency to treat oneself kindly during distress and disappointments, would attenuate the positive relationship between body mass index (BMI) and eating disorder pathology, and the negative relationship between BMI and body image flexibility. One-hundred and fifty-three female undergraduate students completed measures of self-compassion, self-esteem, eating disorder pathology, and body image flexibility, which refers to one's acceptance of negative body image experiences. Controlling for self-esteem, hierarchical regressions revealed that self-compassion moderated the relationships between BMI and the criteria. Specifically, the positive relationship between BMI and eating disorder pathology and the negative relationship between BMI and body image flexibility were weaker the higher women's levels of self-compassion. Among young women, self-compassion may help to protect against the greater eating disturbances that coincide with a higher BMI, and may facilitate the positive body image experiences that tend to be lower the higher one's BMI. Copyright © 2014 Elsevier Ltd. All rights reserved.
Meta-Analysis of Intelligence Quotient (IQ) in Obsessive-Compulsive Disorder.
Abramovitch, Amitai; Anholt, Gideon; Raveh-Gottfried, Sagi; Hamo, Naama; Abramowitz, Jonathan S
2018-03-01
Obsessive compulsive disorder (OCD) is associated with a moderate degree of underperformance on cognitive tests, including deficient processing speed. However, despite little research focusing on Intelligence Quotient (IQ) in OCD, it has long been speculated that the disorder is associated with elevated intellectual capacity. The present meta-analytic study was, therefore, conducted to quantitatively summarize the literature on IQ in OCD systematically. We identified 98 studies containing IQ data among individuals with OCD and non-psychiatric comparison groups, and computed 108 effect sizes for Verbal IQ (VIQ, n = 55), Performance IQ (PIQ, n = 13), and Full Scale IQ (FSIQ, n = 40). Across studies, small effect sizes were found for FSIQ and VIQ, and a moderate effect size for PIQ, exemplifying reduced IQ in OCD. However, mean IQ scores across OCD samples were in the normative range. Moderator analyses revealed no significant moderating effect across clinical and demographic indices. We conclude that, although lower than controls, OCD is associated with normative FSIQ and VIQ, and relatively lowered PIQ. These results are discussed in light of neuropsychological research in OCD, and particularly the putative impact of reduced processing speed in this population. Recommendations for utilization of IQ tests in OCD, and directions for future studies are offered.
Drug release from porous silicon for stable neural interface
NASA Astrophysics Data System (ADS)
Sun, Tao; Tsang, Wei Mong; Park, Woo-Tae
2014-02-01
70 μm-thick porous Si (PSi) layer with the pore size of 11.1 ± 7.6 nm was formed on an 8-in. Si wafer via an anodization process for the microfabrication of a microelectrode to record neural signals. To reduce host tissue responses to the microelectrode and achieve a stable neural interface, water-soluble dexamethesone (Dex) was loaded into the PSi via incubation with the drug solution overnight. After the drug loading process, the pore size of PSi reduced to 4.7 ± 2.6 nm on the basis of scanning electron microscopic (SEM) images, while its wettability was remarkably enhanced. Fluorescence images demonstrated that Dex was loaded into the porous structure of the PSi. Degradation rate of the PSi was investigated by incubation in distilled water for 21 days. Moreover, the drug release profile of the Dex-loaded PSi was a combination of an initial burst release and subsequent sustained release. To evaluate cellular responses to the drug release from the PSi, primary astrocytes were seeded on the surface of samples. After 2 days of culture, the Dex-loaded PSi could not only moderately prevent astrocyte adhesion in comparison with Si, but also more effectively suppress the activation of primary astrocytes than unloaded PSi due to the drug release. Therefore, it might be an effective method to reduce host tissue responses and stabilize the quality of the recorded neural signal by means of loading drugs into the PSi component of the microelectrode.
Determination of Ice Cloud Models Using MODIS and MISR Data
NASA Technical Reports Server (NTRS)
Xie, Yu; Yang, Ping; Kattawar, George W.; Minnis, Patrick; Hu, Yongxiang; Wu, Dong L.
2012-01-01
Representation of ice clouds in radiative transfer simulations is subject to uncertainties associated with the shapes and sizes of ice crystals within cirrus clouds. In this study, we examined several ice cloud models consisting of smooth, roughened, homogeneous and inhomogeneous hexagonal ice crystals with various aspect ratios. The sensitivity of the bulk scattering properties and solar reflectances of cirrus clouds to specific ice cloud models is investigated using the improved geometric optics method (IGOM) and the discrete ordinates radiative transfer (DISORT) model. The ice crystal habit fractions in the ice cloud model may significantly affect the simulations of cloud reflectances. A new algorithm was developed to help determine an appropriate ice cloud model for application to the satellite-based retrieval of ice cloud properties. The ice cloud particle size retrieved from Moderate Resolution Imaging Spectroradiometer (MODIS) data, collocated with Multi-angle Imaging Spectroradiometer (MISR) observations, is used to infer the optical thicknesses of ice clouds for nine MISR viewing angles. The relative differences between view-dependent cloud optical thickness and the averaged value over the nine MISR viewing angles can vary from -0.5 to 0.5 and are used to evaluate the ice cloud models. In the case for 2 July 2009, the ice cloud model with mixed ice crystal habits is the best fit to the observations (the root mean square (RMS) error of cloud optical thickness reaches 0.365). This ice cloud model also produces consistent cloud property retrievals for the nine MISR viewing configurations within the measurement uncertainties.
Firmin, Ruth L; Luther, Lauren; Lysaker, Paul H; Minor, Kyle S; Salyers, Michelle P
2016-08-01
To better understand how stigma resistance impacts functioning-related domains, we examined mean effect sizes between stigma resistance and: 1) symptoms (overall, positive, negative, and mood symptoms); 2) self-stigma; 3) self-efficacy; 4) quality of life; 5) recovery; 6) hope; 7) insight, and 8) overall outcomes (the average effect size across the constructs examined in each study). The mean effect size between stigma resistance and overall outcomes was significant and positive (r=0.46, p<0.001, k=48). A large, negative effect size was found between stigma resistance and self-stigma (r=-0.57, p<0.001, k=40). Large, positive effect sizes were found with self-efficacy (r=0.60, p<0.001, k=25), quality of life (r=0.51, p<0.001, k=17), hope (r=0.54, p<0.001, k=8), and recovery (r=0.60, p<0.001, k=7). Stigma resistance had a significant medium and small relationship with insight and symptoms, respectively. Race significantly moderated overall outcomes, self-stigma, mood symptoms, functioning, and hope associations. Education significantly moderated symptoms, functioning, and mood symptoms associations, and age significantly moderated self-stigma and negative symptom associations. Stigma resistance may be a key requirement for recovery. Individual characteristics influence resisting stigma and future work should prioritize cultural factors surrounding stigma resistance. Copyright © 2016 Elsevier B.V. All rights reserved.
Qiu, Jianjun; Li, Yangyang; Huang, Qin; Wang, Yang; Li, Pengcheng
2013-11-18
In laser speckle contrast imaging, it was usually suggested that speckle size should exceed two camera pixels to eliminate the spatial averaging effect. In this work, we show the benefit of enhancing signal to noise ratio by correcting the speckle contrast at small speckle size. Through simulations and experiments, we demonstrated that local speckle contrast, even at speckle size much smaller than one pixel size, can be corrected through dividing the original speckle contrast by the static speckle contrast. Moreover, we show a 50% higher signal to noise ratio of the speckle contrast image at speckle size below 0.5 pixel size than that at speckle size of two pixels. These results indicate the possibility of selecting a relatively large aperture to simultaneously ensure sufficient light intensity and high accuracy and signal to noise ratio, making the laser speckle contrast imaging more flexible.
Thompson, J K; Dolce, J J
1989-05-01
Thirty-two asymptomatic college females were assessed on multiple aspects of body image. Subjects' estimation of the size of three body sites (waist, hips, thighs) was affected by instructional protocol. Emotional ratings, based on how they "felt" about their body, elicited ratings that were larger than actual and ideal size measures. Size ratings based on rational instructions were no different from actual sizes, but were larger than ideal ratings. There were no differences between actual and ideal sizes. The results are discussed with regard to methodological issues involved in body image research. In addition, a working hypothesis that differentiates affective/emotional from cognitive/rational aspects of body size estimation is offered to complement current theories of body image. Implications of the findings for the understanding of body image and its relationship to eating disorders are discussed.
Probabilistic model for quick detection of dissimilar binary images
NASA Astrophysics Data System (ADS)
Mustafa, Adnan A. Y.
2015-09-01
We present a quick method to detect dissimilar binary images. The method is based on a "probabilistic matching model" for image matching. The matching model is used to predict the probability of occurrence of distinct-dissimilar image pairs (completely different images) when matching one image to another. Based on this model, distinct-dissimilar images can be detected by matching only a few points between two images with high confidence, namely 11 points for a 99.9% successful detection rate. For image pairs that are dissimilar but not distinct-dissimilar, more points need to be mapped. The number of points required to attain a certain successful detection rate or confidence depends on the amount of similarity between the compared images. As this similarity increases, more points are required. For example, images that differ by 1% can be detected by mapping fewer than 70 points on average. More importantly, the model is image size invariant; so, images of any sizes will produce high confidence levels with a limited number of matched points. As a result, this method does not suffer from the image size handicap that impedes current methods. We report on extensive tests conducted on real images of different sizes.
NASA Astrophysics Data System (ADS)
Lejoly, Cassandra; Howell, Ellen S.; Taylor, Patrick A.; Springmann, Alessondra; Virkki, Anne; Nolan, Michael C.; Rivera-Valentin, Edgard G.; Benner, Lance A. M.; Brozovic, Marina; Giorgini, Jon D.
2017-10-01
The Near-Earth Asteroid (NEA) population ranges in size from a few meters to more than 10 kilometers. NEAs have a wide variety of taxonomic classes, surface features, and shapes, including spheroids, binary objects, contact binaries, elongated, as well as irregular bodies. Using the Arecibo Observatory planetary radar system, we have measured apparent rotation rate, radar reflectivity, apparent diameter, and radar albedos for over 350 NEAs. The radar albedo is defined as the radar cross-section divided by the geometric cross-section. If a shape model is available, the actual cross-section is known at the time of the observation. Otherwise we derive a geometric cross-section from a measured diameter. When radar imaging is available, the diameter was measured from the apparent range depth. However, when radar imaging was not available, we used the continuous wave (CW) bandwidth radar measurements in conjunction with the period of the object. The CW bandwidth provides apparent rotation rate, which, given an independent rotation measurement, such as from lightcurves, constrains the size of the object. We assumed an equatorial view unless we knew the pole orientation, which gives a lower limit on the diameter. The CW also provides the polarization ratio, which is the ratio of the SC and OC cross-sections.We confirm the trend found by Benner et al. (2008) that taxonomic types E and V have very high polarization ratios. We have obtained a larger sample and can analyze additional trends with spin, size, rotation rate, taxonomic class, polarization ratio, and radar albedo to interpret the origin of the NEAs and their dynamical processes. The distribution of radar albedo and polarization ratio at the smallest diameters (≤50 m) differs from the distribution of larger objects (>50 m), although the sample size is limited. Additionally, we find more moderate radar albedos for the smallest NEAs when compared to those with diameters 50-150 m. We will present additional trends we find in this data set.
Fraas, A.P.; Mills, C.B.
1961-11-21
A neutronic reactor in which neutron moderation is achieved primarily in its reflector is described. The reactor structure consists of a cylindrical central "island" of moderator and a spherical moderating reflector spaced therefrom, thereby providing an annular space. An essentially unmoderated liquid fuel is continuously passed through the annular space and undergoes fission while contained therein. The reactor, because of its small size, is particularly adapted for propulsion uses, including the propulsion of aircraft. (AEC)
Multi-Scale Fractal Analysis of Image Texture and Pattern
NASA Technical Reports Server (NTRS)
Emerson, Charles W.; Lam, Nina Siu-Ngan; Quattrochi, Dale A.
1999-01-01
Analyses of the fractal dimension of Normalized Difference Vegetation Index (NDVI) images of homogeneous land covers near Huntsville, Alabama revealed that the fractal dimension of an image of an agricultural land cover indicates greater complexity as pixel size increases, a forested land cover gradually grows smoother, and an urban image remains roughly self-similar over the range of pixel sizes analyzed (10 to 80 meters). A similar analysis of Landsat Thematic Mapper images of the East Humboldt Range in Nevada taken four months apart show a more complex relation between pixel size and fractal dimension. The major visible difference between the spring and late summer NDVI images is the absence of high elevation snow cover in the summer image. This change significantly alters the relation between fractal dimension and pixel size. The slope of the fractal dimension-resolution relation provides indications of how image classification or feature identification will be affected by changes in sensor spatial resolution.
Multi-Scale Fractal Analysis of Image Texture and Pattern
NASA Technical Reports Server (NTRS)
Emerson, Charles W.; Lam, Nina Siu-Ngan; Quattrochi, Dale A.
1999-01-01
Analyses of the fractal dimension of Normalized Difference Vegetation Index (NDVI) images of homogeneous land covers near Huntsville, Alabama revealed that the fractal dimension of an image of an agricultural land cover indicates greater complexity as pixel size increases, a forested land cover gradually grows smoother, and an urban image remains roughly self-similar over the range of pixel sizes analyzed (10 to 80 meters). A similar analysis of Landsat Thematic Mapper images of the East Humboldt Range in Nevada taken four months apart show a more complex relation between pixel size and fractal dimension. The major visible difference between the spring and late summer NDVI images of the absence of high elevation snow cover in the summer image. This change significantly alters the relation between fractal dimension and pixel size. The slope of the fractal dimensional-resolution relation provides indications of how image classification or feature identification will be affected by changes in sensor spatial resolution.
Hou, Gary Y; Luo, Jianwen; Marquet, Fabrice; Maleke, Caroline; Vappou, Jonathan; Konofagou, Elisa E
2011-12-01
Harmonic motion imaging for focused ultrasound (HMIFU) is a novel high-intensity focused ultrasound (HIFU) therapy monitoring method with feasibilities demonstrated in vitro, ex vivo and in vivo. Its principle is based on amplitude-modulated (AM) - harmonic motion imaging (HMI), an oscillatory radiation force used for imaging the tissue mechanical response during thermal ablation. In this study, a theoretical framework of HMIFU is presented, comprising a customized nonlinear wave propagation model, a finite-element (FE) analysis module and an image-formation model. The objective of this study is to develop such a framework to (1) assess the fundamental performance of HMIFU in detecting HIFU lesions based on the change in tissue apparent elasticity, i.e., the increasing Young's modulus, and the HIFU lesion size with respect to the HIFU exposure time and (2) validate the simulation findings ex vivo. The same HMI and HMIFU parameters as in the experimental studies were used, i.e., 4.5-MHz HIFU frequency and 25 Hz AM frequency. For a lesion-to-background Young's modulus ratio of 3, 6 and 9, the FE and estimated HMI displacement ratios were equal to 1.83, 3.69 and 5.39 and 1.65, 3.19 and 4.59, respectively. In experiments, the HMI displacement followed a similar increasing trend of 1.19, 1.28 and 1.78 at 10-s, 20-s and 30-s HIFU exposure, respectively. In addition, moderate agreement in lesion size growth was found in both simulations (16.2, 73.1 and 334.7 mm(2)) and experiments (26.2, 94.2 and 206.2 mm(2)). Therefore, the feasibility of HMIFU for HIFU lesion detection based on the underlying tissue elasticity changes was verified through the developed theoretical framework, i.e., validation of the fundamental performance of the HMIFU system for lesion detection, localization and quantification, was demonstrated both theoretically and ex vivo. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Mehrabi, Sara; Adami, Alessia; Ventriglia, Anna; Zantedeschi, Lisa; Franchi, Massimo; Manfredi, Riccardo
2013-10-01
We evaluated the evolution of ventriculomegaly (VM) by comparing foetal magnetic resonance imaging (MRI) with postnatal transcranial ultrasonography (US) and/or encephalic MRI. Between January 2006 and April 2011, 70 foetuses with a mean gestational age of 28 weeks and 4 days (range, 18-36) weeks with VM on foetal MRI were assessed in this prospective study. Half-Fourier rapid acquisition with relaxation enhancement (RARE) T2-weighted, T1-weighted and diffusion-weighted (DWI) images along the three orthogonal planes according to the longitudinal axis of the mother, and subsequently of the foetal brain, were acquired. Quantitative image analysis included the transverse diameter of lateral ventricles in axial and coronal planes. Qualitative image analysis included searching for associated structural anomalies. Thirty-four of 70 patients with a diagnosis of VM on foetal MRI underwent postnatal imaging. Twenty-five of those 34 (73%) had mild, four (12%) had moderate and five (15%) had severe VM on MRI. Normalisation of the diameter of lateral ventricles was observed in 16 of the 34 (47%) newborns. Among these 16, 13 (81%) had mild and three (19%) had moderate VM (two isolated and one associated VM). VM stabilisation was observed in 16 of the 34 (47%) babies. Among them, 11 (69%) had mild (eight isolated and three associated), one (6%) had moderate associated and four (25%) had severe associated VM. Progression from mild to severe (associated) VM was observed in two of the 34 (6%) babies. The absence of associated anomalies and a mild VM are favourable prognostic factors in the evolution of VM.
Cone beam computed tomography in veterinary dentistry.
Van Thielen, Bert; Siguenza, Francis; Hassan, Bassam
2012-01-01
The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstructions were created using specialized software. Image quality and visibility of anatomical landmarks were subjectively assessed by two observers. Good image quality was obtained for the MPR para-sagittal reconstructions through multiple teeth. The image quality of the panoramic reconstructions of dogs was moderate while the panoramic reconstructions of cats were poor since the images were associated with an increased noise level. Segmental panoramic reconstructions of the mouth seem to be useful for studying the dental anatomy especially in dogs. The results of this study using human dental CBCT technology demonstrate the potential of this scanning technology in veterinary medicine. Unfortunately, the moderate image quality obtained with the CBCT technique reported here seems to be inferior to the diagnostic image quality obtained from 2-dimensional dental radiographs. Further research is required to optimize scanning and reconstruction protocols for veterinary applications.
Green, Rebekah
2014-01-01
Universities and colleges provide students with an opportunity to grow personally and professionally through a structured series of learning experiences. Yet disasters can interrupt traditional place-based education and prove to be intractable policy problems. The challenges of developing robust plans and drilling them extensively are most pronounced among smaller public colleges and universities. This article describes how three small- to moderate-sized higher education institutions formed a consortium to better prepare for emergencies, despite limited resources. Together the institutions built common templates, hired joint staff, and created a suit of joint exercises appropriate for their small size and campus-specific needs. In the process, they shared unique perspectives that improved resilience across the institutions.
Parallel Optical Random Access Memory (PORAM)
NASA Technical Reports Server (NTRS)
Alphonse, G. A.
1989-01-01
It is shown that the need to minimize component count, power and size, and to maximize packing density require a parallel optical random access memory to be designed in a two-level hierarchy: a modular level and an interconnect level. Three module designs are proposed, in the order of research and development requirements. The first uses state-of-the-art components, including individually addressed laser diode arrays, acousto-optic (AO) deflectors and magneto-optic (MO) storage medium, aimed at moderate size, moderate power, and high packing density. The next design level uses an electron-trapping (ET) medium to reduce optical power requirements. The third design uses a beam-steering grating surface emitter (GSE) array to reduce size further and minimize the number of components.
Leahey, Tricia M; Crowther, Janis H
2008-09-01
This research examined whether comparison target moderates the effects of naturally occurring appearance-focused social comparisons on women's affect, appearance esteem, and dieting thoughts. During daily activities, body-satisfied (BS) women and body-dissatisfied (BD) women recorded their comparison targets and reactions to comparison information. For BS women, upward comparisons with peers were associated with more positive affect (PA) and appearance esteem and less guilt than upward comparisons with media images and downward comparisons with peers were associated with less PA than downward comparisons with media images. For BD women, upward comparisons with peers were associated with more appearance esteem and diet thoughts than upward comparisons with media images and downward comparisons with peers were associated with less PA, appearance esteem, and diet thoughts and more guilt than downward comparisons with media images.
NASA Astrophysics Data System (ADS)
Cesmeli, Erdogan; Berry, Joel L.; Carr, J. J.
2005-04-01
Proliferation of coronary stent deployment for treatment of coronary heart disease (CHD) creates a need for imaging-based follow-up examinations to assess patency. Technological improvements in multi-detector computer tomography (MDCT) make it a potential non-invasive alternative to coronary catheterization for evaluation of stent patency; however, image quality with MDCT varies based on the size and composition of the stent. We studied the role of tube focal spot size and power in the optimization of image quality in a stationary phantom. A standard uniform physical phantom with a tubular insert was used where coronary stents (4 mm in diameter) were deployed in a tube filled with contrast to simulate a typical imaging condition observed in clinical practice. We utilized different commercially available stents and scanned them with different tube voltage and current settings (LightSpeed Pro16, GE Healthcare Technologies, Waukesha, WI, USA). The scanner used different focal spot size depending on the power load and thus allowed us to assess the combined effect of the focal spot size and the power. A radiologist evaluated the resulting images in terms of image quality and artifacts. For all stents, we found that the small focal spot size yielded better image quality and reduced artifacts. In general, higher power capability for the given focal spot size improved the signal-to-noise ratio in the images allowing improved assessment. Our preliminary study in a non-moving phantom suggests that a CT scanner that can deliver the same power on a small focal spot size is better suited to have an optimized scan protocol for reliable stent assessment.
Remote sensing of cirrus cloud vertical size profile using MODIS data
NASA Astrophysics Data System (ADS)
Wang, Xingjuan; Liou, K. N.; Ou, Steve S. C.; Mace, G. G.; Deng, M.
2009-05-01
This paper describes an algorithm for inferring cirrus cloud top and cloud base effective particle sizes and cloud optical thickness from the Moderate Resolution Imaging Spectroradiometer (MODIS) 0.645, 1.64 and 2.13, and 3.75 μm band reflectances/radiances. This approach uses a successive minimization method based on a look-up library of precomputed reflectances/radiances from an adding-doubling radiative transfer program, subject to corrections for Rayleigh scattering at the 0.645 μm band, above-cloud water vapor absorption, and 3.75 μm thermal emission. The algorithmic accuracy and limitation of the retrieval method were investigated by synthetic retrievals subject to the instrument noise and the perturbation of input parameters. The retrieval algorithm was applied to three MODIS cirrus scenes over the Atmospheric Radiation Measurement Program's southern Great Plain site, north central China, and northeast Asia. The reliability of retrieved cloud optical thicknesses and mean effective particle sizes was evaluated by comparison with MODIS cloud products and qualitatively good correlations were obtained for all three cases, indicating that the performance of the vertical sizing algorithm is comparable with the MODIS retrieval program. Retrieved cloud top and cloud base ice crystal effective sizes were also compared with those derived from the collocated ground-based millimeter wavelength cloud radar for the first case and from the Cloud Profiling Radar onboard CloudSat for the other two cases. Differences between retrieved and radar-derived cloud properties are discussed in light of assumptions made in the collocation process and limitations in radar remote sensing characteristics.
A Meta-analytic Review of Religious or Spiritual Involvement and Social Health among Cancer Patients
Sherman, Allen C; Merluzzi, Thomas V; Pustejovsky, James E; Park, Crystal L; George, Login; Fitchett, George; Jim, Heather SL; Munoz, Alexis R; Danhauer, Suzanne C; Snyder, Mallory A; Salsman, John M
2015-01-01
Background Religion and spirituality (R/S) play an important role in the daily lives of many cancer patients. There has been great interest in determining whether R/S factors are related to clinically-relevant health outcomes. This meta-analytic review examined associations between dimensions of R/S and social health (e.g., social roles and relationships). Methods A systematic search of PubMed, PsycInfo, Cochrane Library, and CINAHL databases was conducted, and data were extracted by four pairs of investigators. Bivariate associations between specific R/S dimensions and social health outcomes were examined in a meta-analysis using a generalized estimating equation (GEE) approach. Results A total of 78 independent samples encompassing 14,277 patients were included in the meta-analysis. Social health was significantly associated with overall R/S (Fisher z effect size = .20, P< .001), and with each of the R/S dimensions (affective R/S effect size = .32, P< .001; cognitive R/S effect size = .11, P< .01; behavioral R/S effect size = .08, P < .05; and ‘other’ R/S effect size = .13, P < .001). Within these dimensions, specific variables tied to social health included spiritual well-being, spiritual struggle, images of God, R/S beliefs, and composite R/S measures (all P’s < .05). None of the demographic or clinical moderating variables examined was significant. Conclusions Several R/S dimensions are modestly associated with patients’ capacity to maintain satisfying social roles and relationships in the context of cancer. Further research is needed to examine the temporal nature of these associations and the mechanisms that underlie them. PMID:26258730
Image Size Variation Influence on Corrupted and Non-viewable BMP Image
NASA Astrophysics Data System (ADS)
Azmi, Tengku Norsuhaila T.; Azma Abdullah, Nurul; Rahman, Nurul Hidayah Ab; Hamid, Isredza Rahmi A.; Chai Wen, Chuah
2017-08-01
Image is one of the evidence component seek in digital forensics. Joint Photographic Experts Group (JPEG) format is most popular used in the Internet because JPEG files are very lossy and easy to compress that can speed up Internet transmitting processes. However, corrupted JPEG images are hard to recover due to the complexities of determining corruption point. Nowadays Bitmap (BMP) images are preferred in image processing compared to another formats because BMP image contain all the image information in a simple format. Therefore, in order to investigate the corruption point in JPEG, the file is required to be converted into BMP format. Nevertheless, there are many things that can influence the corrupting of BMP image such as the changes of image size that make the file non-viewable. In this paper, the experiment indicates that the size of BMP file influences the changes in the image itself through three conditions, deleting, replacing and insertion. From the experiment, we learnt by correcting the file size, it can able to produce a viewable file though partially. Then, it can be investigated further to identify the corruption point.
NASA Astrophysics Data System (ADS)
Wilson, Dennis L.; Glicksman, Robert A.
1994-05-01
A Picture Archiving and Communications System (PACS) must be able to support the image rate of the medical treatment facility. In addition the PACS must have adequate working storage and archive storage capacity required. The calculation of the number of images per minute and the capacity of working storage and of archiving storage is discussed. The calculation takes into account the distribution of images over the different size of radiological images, the distribution between inpatient and outpatient, and the distribution over plain film CR images and other modality images. The support of the indirect clinical image load is difficult to estimate and is considered in some detail. The result of the exercise for a particular hospital is an estimate of the average size of the images and exams on the system, of the number of gigabytes of working storage, of the number of images moved per minute, of the size of the archive in gigabytes, and of the number of images that are to be moved by the archive per minute. The types of storage required to support the image rates and the capacity required are discussed.
A single test for rejecting the null hypothesis in subgroups and in the overall sample.
Lin, Yunzhi; Zhou, Kefei; Ganju, Jitendra
2017-01-01
In clinical trials, some patient subgroups are likely to demonstrate larger effect sizes than other subgroups. For example, the effect size, or informally the benefit with treatment, is often greater in patients with a moderate condition of a disease than in those with a mild condition. A limitation of the usual method of analysis is that it does not incorporate this ordering of effect size by patient subgroup. We propose a test statistic which supplements the conventional test by including this information and simultaneously tests the null hypothesis in pre-specified subgroups and in the overall sample. It results in more power than the conventional test when the differences in effect sizes across subgroups are at least moderately large; otherwise it loses power. The method involves combining p-values from models fit to pre-specified subgroups and the overall sample in a manner that assigns greater weight to subgroups in which a larger effect size is expected. Results are presented for randomized trials with two and three subgroups.
Zhang, Yu-Dong; Zhu, Fei-Peng; Xu, Xun; Wang, Qing; Wu, Chen-Jiang; Liu, Xi-Sheng; Shi, Hai-Bin
2016-02-01
To compare the Liver Imaging Reporting and Data System (LI-RADS) and a criteria-free Likert scale (LS) reporting models for classifying computed tomography/magnetic resonance imaging (CT/MR) findings of suspicious hepatocellular carcinoma (HCC). Imaging data of 281 hepatic nodules in 203 patients were retrospectively included. Imaging characteristics including diameter, arterial hyperenhancement, washout, and capsule were reviewed independently by two groups of readers using LI-RADS and LS (range, score 1-5). LS is primarily based on the overall impression of image findings without using fixed criteria. Interreader agreement (IRA), intraclass agreement (ICA), and diagnostic performance were determined by Fleiss, Cohen's kappa (κ), and logistic regression, respectively. There were 167 contrast-enhanced CT (CECT) versus 114 MR data. Overall, IRA was moderate (κ = 0.47, 0.52); IRA was moderate-to-good for arterial hyperenhancement, washout, and capsule (κ = 0.56-0.69); excellent for diameter and tumor embolus (κ = 0.99). Overall, ICA between LI-RADS and LS was moderate (κ = 0.44-0.50); ICA was good for scores 1-2 (κ = 0.71-0.90), moderate for scores 3 and 5 (κ = 0.41-0.52), but very poor for score 4 (κ = 0.11-0.19). LI-RADS produced significantly lower accuracy (78.6% vs. 87.2%) and sensitivity (72.1% vs. 92.8%), higher specificity (97.3% vs. 71.2%) and positive likelihood ratio (+LR: 26.32 vs. 3.23) in diagnosis of HCC. CECT produced relatively low IRA, ICA, and diagnostic ability against MR. There were substantial variations in liver observations between LI-RADS and LS. Further study is needed to investigate ICA between CECT and MR. © 2015 Wiley Periodicals, Inc.
A critical look at spatial scale choices in satellite-based aerosol indirect effect studies
NASA Astrophysics Data System (ADS)
Grandey, B. S.; Stier, P.
2010-06-01
Analysing satellite datasets over large regions may introduce spurious relationships between aerosol and cloud properties due to spatial variations in aerosol type, cloud regime and synoptic regime climatologies. Using MODerate resolution Imaging Spectroradiometer data, we calculate relationships between aerosol optical depth τa, derived liquid cloud droplet effective number concentration Ne and liquid cloud droplet effective radius re at different spatial scales. Generally, positive values of dlnNe dlnτa are found for ocean regions, whilst negative values occur for many land regions. The spatial distribution of dlnre dlnτa shows approximately the opposite pattern, with generally postive values for land regions and negative values for ocean regions. We find that for region sizes larger than 4°×4°, spurious spatial variations in retrieved cloud and aerosol properties can introduce widespread significant errors to calculations of dlnNe dlnτa and dlnre dlnτa . For regions on the scale of 60°×60°, these methodological errors may lead to an overestimate in global cloud albedo effect radiative forcing of order 80%.
NASA Technical Reports Server (NTRS)
Guenther, Bruce W.; Godden, Gerald D.; Xiong, Xiao-Xiong; Knight, Edward J.; Qiu, Shi-Yue; Montgomery, Harry; Hopkins, M. M.; Khayat, Mohammad G.; Hao, Zhi-Dong; Smith, David E. (Technical Monitor)
2000-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) radiometric calibration product is described for the thermal emissive and the reflective solar bands. Specific sensor design characteristics are identified to assist in understanding how the calibration algorithm software product is designed. The reflected solar band software products of radiance and reflectance factor both are described. The product file format is summarized and the MODIS Characterization Support Team (MCST) Homepage location for the current file format is provided.
Chen, Xiao; Lu, Bin; Yan, Chao-Gan
2018-01-01
Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Streeter, Jason E.; Gessner, Ryan; Miles, Iman; Dayton, Paul A.
2010-01-01
Molecular imaging with ultrasound relies on microbubble contrast agents (MCAs) selectively adhering to a ligand-specific target. Prior studies have shown that only small quantities of microbubbles are retained at their target sites, therefore, enhancing contrast sensitivity to low concentrations of microbubbles is essential to improve molecular imaging techniques. In order to assess the effect of MCA diameter on imaging sensitivity, perfusion and molecular imaging studies were performed with microbubbles of varying size distributions. To assess signal improvement and MCA circulation time as a function of size and concentration, blood perfusion was imaged in rat kidneys using nontargeted size-sorted MCAs with a Siemens Sequoia ultrasound system (Siemans, Mountain View, CA) in cadence pulse sequencing (CPS) mode. Molecular imaging sensitivity improvements were studied with size-sorted αvβ3-targeted bubbles in both fibrosarcoma and R3230 rat tumor models. In perfusion imaging studies, video intensity and contrast persistence was ≈8 times and ≈3 times greater respectively, for “sorted 3-micron” MCAs (diameter, 3.3 ± 1.95 μm) when compared to “unsorted” MCAs (diameter, 0.9 ± 0.45 μm) at low concentrations. In targeted experiments, application of sorted 3-micron MCAs resulted in a ≈20 times video intensity increase over unsorted populations. Tailoring size-distributions results in substantial imaging sensitivity improvement over unsorted populations, which is essential in maximizing sensitivity to small numbers of MCAs for molecular imaging. PMID:20236606
An automated and universal method for measuring mean grain size from a digital image of sediment
Buscombe, Daniel D.; Rubin, David M.; Warrick, Jonathan A.
2010-01-01
Existing methods for estimating mean grain size of sediment in an image require either complicated sequences of image processing (filtering, edge detection, segmentation, etc.) or statistical procedures involving calibration. We present a new approach which uses Fourier methods to calculate grain size directly from the image without requiring calibration. Based on analysis of over 450 images, we found the accuracy to be within approximately 16% across the full range from silt to pebbles. Accuracy is comparable to, or better than, existing digital methods. The new method, in conjunction with recent advances in technology for taking appropriate images of sediment in a range of natural environments, promises to revolutionize the logistics and speed at which grain-size data may be obtained from the field.
Oedema of gallbladder wall: correlation with chronic hepatitis B on MR imaging.
Shu, Jian; Zhao, Jian Nong; Han, Fu Gang; Tang, Guang Cai; Luo, Yin Deng; Chen, Xin; Luo, Li
2013-10-01
The aim of this study was to characterise gallbladder wall oedema and correlate it with chronic hepatitis B (CHB) on magnetic resonance (MR) imaging. Sixty-seven patients who were clinically and histologically diagnosed with CHB and 18 healthy individuals without any history of liver disease underwent abdominal MR imaging. Hepatic inflammation (grade 0-4) and fibrosis (stage 0-4) for patients were assessed histologically. Gallbladder wall oedema was noted. Twelve patients showed gallbladder wall oedema on MR imaging, including six with grade 3 and six with grade 4 disease. There was a statistically significant difference for the presence of gallbladder wall oedema among groups with grade 0-4 (p=0.000), but not between groups with grades 3 and 4 (p=0.729). Gallbladder wall oedema was related to moderate-severe inflammatory activity (p<0.05), alanine transaminase (ALT) (p=0.012) and aspartate aminotransferase (AST) (p=0.027) levels but not to fibrosis or other laboratory data, including serum quantitative DNA for hepatitis B virus (HBV), with the p=0.105-0.846. Sensitivity and specificity for the diagnosis of hepatic moderate-severe inflammation using gallbladder wall oedema were 33.33% and 100%, respectively. Gallbladder wall oedema for patients with CHB can be specifically demonstrated on MR imaging and is correlated with hepatic moderate-severe inflammatory activity, elevated ALT and AST levels but not with fibrosis or other laboratory data, including viremia.
Park, Kay-Hyun; Chung, Suryeun; Kim, Dong Jung; Kim, Jun Sung; Lim, Cheong
2017-05-01
For a moderately dilated ascending aorta (diameter 35-54 mm), current guidelines recommend continuous annual or semi-annual examinations with computed tomography or magnetic resonance imaging. However, few data have shown the yield and benefit of such a protocol. This study aimed to investigate the fate of a moderately dilated ascending aorta and thereby determine the adequate imaging interval. In our institutional database, we identified adult patients having an ascending aortic diameter ≥40 mm in contrast-enhanced computed tomography and follow-up imaging(s) after ≥1 year. Of the 509 patients (mean age 67.2 ± 10.4 years) enrolled in the study, the maximal diameter of the ascending aorta was compared between the first and last images. Also, their medical records were reviewed to investigate the associated illness and clinical events. The mean growth rate of the patients with a 40-44 mm ( n = 321), 45-49 mm ( n = 142) and ≥50 mm ( n = 46) ascending aorta was 0.3 ± 0.5, 0.3 ± 0.5 and 0.7 ± 0.9 mm/year, respectively. During the mean interval of 4.3 ± 2.4 years, significant progression (diameter increase by ≥5 mm) occurred in 3.4, 5.6 and 21.7%, respectively. The 3- to 5-year rates of freedom from significant progression were 99.1%-96.5% (40-44 mm) and 97.8%-96.4% (45-49 mm). In multivariate analysis, initial ascending aortic diameter ≥45 mm and aortic valve regurgitation were significantly associated with significant progression. Acute type A aortic dissection occurred in 5 patients (1%), before the maximal diameter of the ascending aorta reached 55 mm or significant progression was observed. For a moderately dilated ascending aorta not exceeding 45 mm in maximal diameter and stable in the first annual follow-up image, a 3- to 4-year interval would be reasonable before subsequent imaging. More frequent imaging may be warranted in patients with aortic valve insufficiency or with an aortic diameter ≥45 mm. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Pena-Verdeal, Hugo; Garcia-Resua, Carlos; Yebra-Pimentel, Eva; Giraldez, Maria J.
2017-08-01
Purpose: Different lower tear meniscus parameters can be clinical assessed on dry eye diagnosis. The aim of this study was to propose and analyse the variability of a semi-automatic method for measuring lower tear meniscus central area (TMCA) by using open source software. Material and methods: On a group of 105 subjects, one video of the lower tear meniscus after fluorescein instillation was generated by a digital camera attached to a slit-lamp. A short light beam (3x5 mm) with moderate illumination in the central portion of the meniscus (6 o'clock) was used. Images were extracted from each video by a masked observer. By using an open source software based on Java (NIH ImageJ), a further observer measured in a masked and randomized order the TMCA in the short light beam illuminated area by two methods: (1) manual method, where TMCA images was "manually" measured; (2) semi-automatic method, where TMCA images were transformed in an 8-bit-binary image, then holes inside this shape were filled and on the isolated shape, the area size was obtained. Finally, both measurements, manual and semi-automatic, were compared. Results: Paired t-test showed no statistical difference between both techniques results (p = 0.102). Pearson correlation between techniques show a significant positive near to perfect correlation (r = 0.99; p < 0.001). Conclusions: This study showed a useful tool to objectively measure the frontal central area of the meniscus in photography by free open source software.
Self-objectification and disordered eating: A meta-analysis.
Schaefer, Lauren M; Thompson, J Kevin
2018-06-01
Objectification theory posits that self-objectification increases risk for disordered eating. The current study sought to examine the relationship between self-objectification and disordered eating using meta-analytic techniques. Data from 53 cross-sectional studies (73 effect sizes) revealed a significant moderate positive overall effect (r = .39), which was moderated by gender, ethnicity, sexual orientation, and measurement of self-objectification. Specifically, larger effect sizes were associated with female samples and the Objectified Body Consciousness Scale. Effect sizes were smaller among heterosexual men and African American samples. Age, body mass index, country of origin, measurement of disordered eating, sample type and publication type were not significant moderators. Overall, results from the first meta-analysis to examine the relationship between self-objectification and disordered eating provide support for one of the major tenets of objectification theory and suggest that self-objectification may be a meaningful target in eating disorder interventions, though further work is needed to establish temporal and causal relationships. Findings highlight current gaps in the literature (e.g., limited representation of males, and ethnic and sexual minorities) with implications for guiding future research. © 2018 Wiley Periodicals, Inc.
A Case Study of Ships Forming and Not Forming Tracks in Moderately Polluted Clouds.
NASA Astrophysics Data System (ADS)
Noone, Kevin J.; Öström, Elisabeth; Ferek, Ronald J.; Garrett, Tim; Hobbs, Peter V.; Johnson, Doug W.; Taylor, Jonathan P.; Russell, Lynn M.; Flagan, Richard C.; Seinfeld, John H.; O'Dowd, Colin D.; Smith, Michael H.; Durkee, Philip A.; Nielsen, Kurt; Hudson, James G.; Pockalny, Robert A.; de Bock, Lieve; van Grieken, René E.; Gasparovic, Richard F.; Brooks, Ian
2000-08-01
The effects of anthropogenic particulate emissions from ships on the radiative, microphysical, and chemical properties of moderately polluted marine stratiform clouds are examined. A case study of two ships in the same air mass is presented where one of the vessels caused a discernible ship track while the other did not. In situ measurements of cloud droplet size distributions, liquid water content, and cloud radiative properties, as well as aerosol size distributions (outside cloud, interstitial, and cloud droplet residual particles) and aerosol chemistry, are presented. These are related to measurements of cloud radiative properties. The differences between the aerosol in the two ship plumes are discussed;these indicate that combustion-derived particles in the size range of about 0.03-0.3-m radius were those that caused the microphysical changes in the clouds that were responsible for the ship track.The authors examine the processes behind ship track formation in a moderately polluted marine boundary layer as an example of the effects that anthropogenic particulate pollution can have in the albedo of marine stratiform clouds.
ERIC Educational Resources Information Center
Metcalf, Richard M.
Although there has been previous research concerned with image size, brightness, and contrast in projection standards, the work has lacked careful conceptualization. In this study, size was measured in terms of the visual angle subtended by the material, brightness was stated in foot-lamberts, and contrast was defined as the ratio of the…
Which is the Ideal Breast Size?: Some Social Clues for Plastic Surgeons.
Raposio, Edoardo; Belgrano, Valerio; Santi, PierLuigi; Chiorri, Carlo
2016-03-01
To provide plastic surgeons with more detailed information as to factors affecting the perception of female attractiveness, the present study was aimed to investigate whether the interaction effect of breast and body size on ratings of female attractiveness is moderated by sociodemographic variables and whether ratings of shapeliness diverge from those of attractiveness.A community sample of 958 Italian participants rated the attractiveness and the shapeliness of 15 stimuli (5 breast sizes × 3 body sizes) in which frontal, 3/4, and profile views of the head and torso of a faceless woman were jointly shown.Bigger breast sizes obtained the highest attractiveness ratings, but the breast-by-body size interaction was also significant. Evidence was found of a moderator role of sex, marital status, and age. When the effects of breast and body size and their interaction had been ruled out, sex differences were at best very slight and limited to very specific combinations of breast and body sizes. Ratings of attractiveness and shapeliness were highly correlated and did not significantly differ.Results suggest that to address women's psychological needs, concerns, and expectations about their appearance, plastic surgeons should not simply focus on breast size but should carefully consider the 'big picture': the body in its entirety.
Rodrigues, Michael L M; Leão, Versiane A; Gomes, Otavio; Lambert, Fanny; Bastin, David; Gaydardzhiev, Stoyan
2015-07-01
The current work reports on a new approach for copper bioleaching from Printed Circuit Board (PCB) by moderate thermophiles in a rotating-drum reactor. Initially leaching of PCB was carried out in shake flasks to assess the effects of particle size (-208μm+147μm), ferrous iron concentration (1.25-10.0g/L) and pH (1.5-2.5) on copper leaching using mesophile and moderate thermophile microorganisms. Only at a relatively low solid content (10.0g/L) complete copper extraction was achieved from the particle size investigated. Conversely, high copper extractions were possible from coarse-ground PCB (20mm-long) working with increased solids concentration (up to 25.0g/L). Because there was as the faster leaching kinetics at 50°C Sulfobacillus thermosulfidooxidans was selected for experiments in a rotating-drum reactor with the coarser-sized PCB sheets. Under optimal conditions, copper extraction reached 85%, in 8days and microscopic observations by SEM-EDS of the on non-leached and leached material suggested that metal dissolution from the internal layers was restricted by the fact that metal surface was not entirely available and accessible for the solution in the case of the 20mm-size sheets. Copyright © 2015 Elsevier Ltd. All rights reserved.
Atmospheric Science Data Center
2017-04-26
... Moderate Resolution Imaging Spectrometer (MODIS) Airborne Simulator (MAS) Data Project Title: MAS ... IDL Code ER2 Flight Tracks Related Data: MAS Additional Info: ER-2 MODIS Airborne Simulator (MAS) Image Gallery: ...
Sauropod dinosaurs evolved moderately sized genomes unrelated to body size.
Organ, Chris L; Brusatte, Stephen L; Stein, Koen
2009-12-22
Sauropodomorph dinosaurs include the largest land animals to have ever lived, some reaching up to 10 times the mass of an African elephant. Despite their status defining the upper range for body size in land animals, it remains unknown whether sauropodomorphs evolved larger-sized genomes than non-avian theropods, their sister taxon, or whether a relationship exists between genome size and body size in dinosaurs, two questions critical for understanding broad patterns of genome evolution in dinosaurs. Here we report inferences of genome size for 10 sauropodomorph taxa. The estimates are derived from a Bayesian phylogenetic generalized least squares approach that generates posterior distributions of regression models relating genome size to osteocyte lacunae volume in extant tetrapods. We estimate that the average genome size of sauropodomorphs was 2.02 pg (range of species means: 1.77-2.21 pg), a value in the upper range of extant birds (mean = 1.42 pg, range: 0.97-2.16 pg) and near the average for extant non-avian reptiles (mean = 2.24 pg, range: 1.05-5.44 pg). The results suggest that the variation in size and architecture of genomes in extinct dinosaurs was lower than the variation found in mammals. A substantial difference in genome size separates the two major clades within dinosaurs, Ornithischia (large genomes) and Saurischia (moderate to small genomes). We find no relationship between body size and estimated genome size in extinct dinosaurs, which suggests that neutral forces did not dominate the evolution of genome size in this group.
The Importance of Neurogenic Inflammation in Blast-Induced Neurotrauma
2013-01-01
mild/moderate BINT are imaged by magnetic resonance imaging ( MRI ) to visualize potential macrophage infiltration; blood-brain barrier (BBB) disturbance...TERMS blast, traumatic brain injury, brain, inflammation, magnetic resonance imaging , mice 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...monitoring the success of therapeutic interventions. In this annual report we have utilized current live imaging methods (i.e. magnetic resonance
ERIC Educational Resources Information Center
Ritzhaupt, Albert Dieter; Barron, Ann
2008-01-01
The purpose of this study was to investigate the effect of time-compressed narration and representational adjunct images on a learner's ability to recall and recognize information. The experiment was a 4 Audio Speeds (1.0 = normal vs. 1.5 = moderate vs. 2.0 = fast vs. 2.5 = fastest rate) x Adjunct Image (Image Present vs. Image Absent) factorial…
NASA Technical Reports Server (NTRS)
2002-01-01
This spectacular Moderate Resolution Imaging Spectroradiometer (MODIS) 'blue marble' image is based on the most detailed collection of true-color imagery of the entire Earth to date. Using a collection of satellite-based observations, scientists and visualizers stitched together months of observations of the land surface, oceans, sea ice, and clouds into a seamless, true-color mosaic of every square kilometer (.386 square mile) of our planet. Most of the information contained in this image came from MODIS, illustrating MODIS' outstanding capacity to act as an integrated tool for observing a variety of terrestrial, oceanic, and atmospheric features of the Earth. The land and coastal ocean portions of this image is based on surface observations collected from June through September 2001 and combined, or composited, every eight days to compensate for clouds that might block the satellite's view on any single day. Global ocean color (or chlorophyll) data was used to simulate the ocean surface. MODIS doesn't measure 3-D features of the Earth, so the surface observations were draped over topographic data provided by the U.S. Geological Survey EROS Data Center. MODIS observations of polar sea ice were combined with observations of Antarctica made by the National Oceanic and Atmospheric Administration's AVHRR sensor-the Advanced Very High Resolution Radiometer. The cloud image is a composite of two days of MODIS imagery collected in visible light wavelengths and a third day of thermal infra-red imagery over the poles. A large collection of imagery based on the blue marble in a variety of sizes and formats, including animations and the full (1 km) resolution imagery, is available at the Blue Marble page. Image by Reto Stockli, Render by Robert Simmon. Based on data from the MODIS Science Team
Huang, C.; Townshend, J.R.G.; Liang, S.; Kalluri, S.N.V.; DeFries, R.S.
2002-01-01
Measured and modeled point spread functions (PSF) of sensor systems indicate that a significant portion of the recorded signal of each pixel of a satellite image originates from outside the area represented by that pixel. This hinders the ability to derive surface information from satellite images on a per-pixel basis. In this study, the impact of the PSF of the Moderate Resolution Imaging Spectroradiometer (MODIS) 250 m bands was assessed using four images representing different landscapes. Experimental results showed that though differences between pixels derived with and without PSF effects were small on the average, the PSF generally brightened dark objects and darkened bright objects. This impact of the PSF lowered the performance of a support vector machine (SVM) classifier by 5.4% in overall accuracy and increased the overall root mean square error (RMSE) by 2.4% in estimating subpixel percent land cover. An inversion method based on the known PSF model reduced the signals originating from surrounding areas by as much as 53%. This method differs from traditional PSF inversion deconvolution methods in that the PSF was adjusted with lower weighting factors for signals originating from neighboring pixels than those specified by the PSF model. By using this deconvolution method, the lost classification accuracy due to residual impact of PSF effects was reduced to only 1.66% in overall accuracy. The increase in the RMSE of estimated subpixel land cover proportions due to the residual impact of PSF effects was reduced to 0.64%. Spatial aggregation also effectively reduced the errors in estimated land cover proportion images. About 50% of the estimation errors were removed after applying the deconvolution method and aggregating derived proportion images to twice their dimensional pixel size. ?? 2002 Elsevier Science Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follette, Katherine B.; Close, Laird; Tamura, Motohide
We present the first near infrared (NIR) spatially resolved images of the circumstellar transitional disk around SR21. These images were obtained with the Subaru HiCIAO camera, adaptive optics, and the polarized differential imaging technique. We resolve the disk in scattered light at H-band for stellocentric 0.''1 {<=} r {<=} 0.''6 (12 {approx}< r {approx}< 75 AU). We compare our results with previously published spatially resolved 880 {mu}m continuum Submillimeter Array images that show an inner r {approx}< 36 AU cavity in SR21. Radiative transfer models reveal that the large disk depletion factor invoked to explain SR21's sub-mm cavity cannot bemore » 'universal' for all grain sizes. Even significantly more moderate depletions ({delta} = 0.1, 0.01 relative to an undepleted disk) than those that reproduce the sub-mm cavity ({delta} {approx} 10{sup -6}) are inconsistent with our H-band images when they are assumed to carry over to small grains, suggesting that surface grains scattering in the NIR either survive or are generated by whatever mechanism is clearing the disk midplane. In fact, the radial polarized intensity profile of our H-band observations is smooth and steeply inwardly-increasing (r {sup -3}), with no evidence of a break at the 36 AU sub-mm cavity wall. We hypothesize that this profile is dominated by an optically thin disk envelope or atmosphere component. We also discuss the compatibility of our data with the previously postulated existence of a sub-stellar companion to SR21 at r {approx} 10-20 AU, and find that we can neither exclude nor verify this scenario. This study demonstrates the power of multiwavelength imaging of transitional disks to inform modeling efforts, including the debate over precisely what physical mechanism is responsible for clearing these disks of their large midplane grains.« less
AIRS Subpixel Cloud Characterization Using MODIS Cloud Products.
NASA Astrophysics Data System (ADS)
Li, Jun; Menzel, W. Paul; Sun, Fengying; Schmit, Timothy J.; Gurka, James
2004-08-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) measurements from the Earth Observing System's (EOS's) Aqua satellite enable improved global monitoring of the distribution of clouds. MODIS is able to provide, at high spatial resolution (1 5 km), a cloud mask, surface and cloud types, cloud phase, cloud-top pressure (CTP), effective cloud amount (ECA), cloud particle size (CPS), and cloud optical thickness (COT). AIRS is able to provide CTP, ECA, CPS, and COT at coarser spatial resolution (13.5 km at nadir) but with much better accuracy using its high-spectral-resolution measurements. The combined MODIS AIRS system offers the opportunity for improved cloud products over those possible from either system alone. The key steps for synergistic use of imager and sounder radiance measurements are 1) collocation in space and time and 2) imager cloud amount, type, and phase determination within the sounder pixel. The MODIS and AIRS measurements from the EOS Aqua satellite provide the opportunity to study the synergistic use of advanced imager and sounder measurements. As the first step, the MODIS classification procedure is applied to identify various surface and cloud types within an AIRS footprint. Cloud-layer information (lower, midlevel, or high clouds) and phase information (water, ice, or mixed-phase clouds) within the AIRS footprint are sorted and characterized using MODIS 1-km-spatial-resolution data. The combined MODIS and AIRS data for various scenes are analyzed to study the utility of the synergistic use of high-spatial-resolution imager products and high-spectral-resolution sounder radiance measurements. There is relevance to the optimal use of data from the Advanced Baseline Imager (ABI) and Hyperspectral Environmental Suite (HES) systems, which are to fly on the Geostationary Operational Environmental Satellite (GOES)-R.
Radiometric cross-calibration of the Terra MODIS and Landsat 7 ETM+ using an invariant desert site
Choi, T.; Angal, A.; Chander, G.; Xiong, X.
2008-01-01
A methodology for long-term radiometric cross-calibration between the Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) sensors was developed. The approach involves calibration of near-simultaneous surface observations between 2000 and 2007. Fifty-seven cloud-free image pairs were carefully selected over the Libyan desert for this study. The Libyan desert site (+28.55??, +23.39??), located in northern Africa, is a high reflectance site with high spatial, spectral, and temporal uniformity. Because the test site covers about 12 kmx13 km, accurate geometric preprocessing is required to match the footprint size between the two sensors to avoid uncertainties due to residual image misregistration. MODIS Level IB radiometrically corrected products were reprojected to the corresponding ETM+ image's Universal Transverse Mercator (UTM) grid projection. The 30 m pixels from the ETM+ images were aggregated to match the MODIS spatial resolution (250 m in Bands 1 and 2, or 500 m in Bands 3 to 7). The image data from both sensors were converted to absolute units of at-sensor radiance and top-ofatmosphere (TOA) reflectance for the spectrally matching band pairs. For each band pair, a set of fitted coefficients (slope and offset) is provided to quantify the relationships between the testing sensors. This work focuses on long-term stability and correlation of the Terra MODIS and L7 ETM+ sensors using absolute calibration results over the entire mission of the two sensors. Possible uncertainties are also discussed such as spectral differences in matching band pairs, solar zenith angle change during a collection, and differences in solar irradiance models.
Jupiter's Equatorial Region in a Methane band (Time set 1)
NASA Technical Reports Server (NTRS)
1997-01-01
Mosaic of Jupiter's equatorial region at 727 nanometers (nm). The mosaic covers an area of 34,000 kilometers by 22,000 kilometers. Light at 727 nm is moderately absorbed by atmospheric methane. This image shows the features of Jupiter's main visible cloud deck and upper tropospheric haze, with higher features enhanced in brightness over lower features. The dark region near the center of the mosaic is an equatorial 'hotspot' similar to the Galileo Probe entry site. These features are holes in the bright, reflective, equatorial cloud layer where warmer thermal emission from Jupiter's deep atmosphere can pass through. The circulation patterns observed here along with the composition measurements from the Galileo Probe suggest that dry air may be converging and sinking over these regions, maintaining their cloud-free appearance. The bright oval in the upper right of the mosaic as well as the other smaller bright features are examples of upwelling of moist air and condensation.
North is at the top. The mosaic covers latitudes 1 to 19 degrees and is centered at longitude 336 degrees West. The smallest resolved features are tens of kilometers in size. These images were taken on December 17, 1996, at a range of 1.5 million kilometers by the Solid State Imaging system aboard NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoJupiter's Equatorial Region in a Methane band (Time set 4)
NASA Technical Reports Server (NTRS)
1997-01-01
Mosaic of Jupiter's equatorial region at 727 nanometers (nm). The mosaic covers an area of 34,000 kilometers by 22,000 kilometers. Light at 727 nm is moderately absorbed by atmospheric methane. This image shows the features of Jupiter's main visible cloud deck and upper-tropospheric haze, with higher features enhanced in brightness over lower features. The dark region near the center of the mosaic is an equatorial 'hotspot' similar to the Galileo Probe entry site. These features are holes in the bright, reflective, equatorial cloud layer where warmer thermal emission from Jupiter's deep atmosphere can pass through. The circulation patterns observed here along with the composition measurements from the Galileo Probe suggest that dry air may be converging and sinking over these regions, maintaining their cloud-free appearance. The bright oval in the upper right of the mosaic as well as the other smaller bright features are examples of upwelling of moist air and condensation.
North is at the top. The mosaic covers latitudes 1 to 19 degrees and is centered at longitude 336 degrees West. The smallest resolved features are tens of kilometers in size. These images were taken on December 17, 1996, at a range of 1.5 million kilometers by the Solid State Imaging system aboard NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoJupiter's Northern Hemisphere in a Methane Band (Time Set 3)
NASA Technical Reports Server (NTRS)
1997-01-01
Mosaic of Jupiter's northern hemisphere between 10 and 50 degrees latitude. Jupiter's atmospheric circulation is dominated by alternating eastward and westward jets from equatorial to polar latitudes. The direction and speed of these jets in part determine the color and texture of the clouds seen in this mosaic. Also visible are several other common Jovian cloud features, including large white ovals, bright spots, dark spots, interacting vortices, and turbulent chaotic systems. The north-south dimension of each of the two interacting vortices in the upper half of the mosaic is about 3500 kilometers. Light at 727 nanometers is moderately absorbed by atmospheric methane. This mosaic shows the features of Jupiter's main visible cloud deck and upper-tropospheric haze, with higher features enhanced in brightness over lower features.
North is at the top. The images are projected on a sphere, with features being foreshortened towards the north. The planetary limb runs along the right edge of the mosaic. Cloud patterns appear foreshortened as they approach the limb. The smallest resolved features are tens of kilometers in size. These images were taken on April 3, 1997, at a range of 1.4 million kilometers by the Solid State Imaging system (CCD) on NASA's Galileo spacecraft.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov. Background information and educational context for the images can be found at URL http://www.jpl.nasa.gov/galileo/sepoNASA Astrophysics Data System (ADS)
Lai, King C.; Liu, Da-Jiang; Evans, James W.
2017-12-01
For diffusion of two-dimensional homoepitaxial clusters of N atoms on metal (100) surfaces mediated by edge atom hopping, macroscale continuum theory suggests that the diffusion coefficient scales like DN˜ N-β with β =3 /2 . However, we find quite different and diverse behavior in multiple size regimes. These include: (i) facile diffusion for small sizes N <9 ; (ii) slow nucleation-mediated diffusion with small β <1 for "perfect" sizes N = Np= L2 or L (L +1 ) , for L =3 ,4 , ... having unique ground-state shapes, for moderate sizes 9 ≤N ≤O (102) ; the same also applies for N =Np+3 , Np+ 4 , ... (iii) facile diffusion but with large β >2 for N =Np+1 and Np+2 also for moderate sizes 9 ≤N ≤O (102) ; (iv) merging of the above distinct branches and subsequent anomalous scaling with 1 ≲β <3 /2 , reflecting the quasifacetted structure of clusters, for larger N =O (102) to N =O (103) ; (v) classic scaling with β =3 /2 for very large N =O (103) and above. The specified size ranges apply for typical model parameters. We focus on the moderate size regime where we show that diffusivity cycles quasiperiodically from the slowest branch for Np+3 (not Np) to the fastest branch for Np+1 . Behavior is quantified by kinetic Monte Carlo simulation of an appropriate stochastic lattice-gas model. However, precise analysis must account for a strong enhancement of diffusivity for short time increments due to back correlation in the cluster motion. Further understanding of this enhancement, of anomalous size scaling behavior, and of the merging of various branches, is facilitated by combinatorial analysis of the number of the ground-state and low-lying excited state cluster configurations, and also of kink populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lai, King C.; Liu, Da -Jiang; Evans, James W.
For diffusion of two-dimensional homoepitaxial clusters of N atoms on metal(100) surfaces mediated by edge atom hopping, macroscale continuum theory suggests that the diffusion coefficient scales like DN ~ N -β with β = 3/2. However, we find quite different and diverse behavior in multiple size regimes. These include: (i) facile diffusion for small sizes N < 9; (ii) slow nucleation-mediated diffusion with small β < 1 for “perfect” sizes N = N p = L 2 or L(L+1), for L = 3, 4,… having unique ground state shapes, for moderate sizes 9 ≤ N ≤ O(10 2); the samemore » also applies for N = N p +3, N p + 4,… (iii) facile diffusion but with large β > 2 for N = Np + 1 and N p + 2 also for moderate sizes 9 ≤ N ≤ O(10 2); (iv) merging of the above distinct branches and subsequent anomalous scaling with 1 ≲ β < 3/2, reflecting the quasi-facetted structure of clusters, for larger N = O(10 2) to N = O(10 3); and (v) classic scaling with β = 3/2 for very large N = O(103) and above. The specified size ranges apply for typical model parameters. We focus on the moderate size regime where show that diffusivity cycles quasi-periodically from the slowest branch for N p + 3 (not Np) to the fastest branch for Np + 1. Behavior is quantified by Kinetic Monte Carlo simulation of an appropriate stochastic lattice-gas model. However, precise analysis must account for a strong enhancement of diffusivity for short time increments due to back-correlation in the cluster motion. Further understanding of this enhancement, of anomalous size scaling behavior, and of the merging of various branches, is facilitated by combinatorial analysis of the number of the ground state and low-lying excited state cluster configurations, and also of kink populations.« less
Lai, King C.; Liu, Da -Jiang; Evans, James W.
2017-12-05
For diffusion of two-dimensional homoepitaxial clusters of N atoms on metal(100) surfaces mediated by edge atom hopping, macroscale continuum theory suggests that the diffusion coefficient scales like DN ~ N -β with β = 3/2. However, we find quite different and diverse behavior in multiple size regimes. These include: (i) facile diffusion for small sizes N < 9; (ii) slow nucleation-mediated diffusion with small β < 1 for “perfect” sizes N = N p = L 2 or L(L+1), for L = 3, 4,… having unique ground state shapes, for moderate sizes 9 ≤ N ≤ O(10 2); the samemore » also applies for N = N p +3, N p + 4,… (iii) facile diffusion but with large β > 2 for N = Np + 1 and N p + 2 also for moderate sizes 9 ≤ N ≤ O(10 2); (iv) merging of the above distinct branches and subsequent anomalous scaling with 1 ≲ β < 3/2, reflecting the quasi-facetted structure of clusters, for larger N = O(10 2) to N = O(10 3); and (v) classic scaling with β = 3/2 for very large N = O(103) and above. The specified size ranges apply for typical model parameters. We focus on the moderate size regime where show that diffusivity cycles quasi-periodically from the slowest branch for N p + 3 (not Np) to the fastest branch for Np + 1. Behavior is quantified by Kinetic Monte Carlo simulation of an appropriate stochastic lattice-gas model. However, precise analysis must account for a strong enhancement of diffusivity for short time increments due to back-correlation in the cluster motion. Further understanding of this enhancement, of anomalous size scaling behavior, and of the merging of various branches, is facilitated by combinatorial analysis of the number of the ground state and low-lying excited state cluster configurations, and also of kink populations.« less
Cloud Engineering Principles and Technology Enablers for Medical Image Processing-as-a-Service.
Bao, Shunxing; Plassard, Andrew J; Landman, Bennett A; Gokhale, Aniruddha
2017-04-01
Traditional in-house, laboratory-based medical imaging studies use hierarchical data structures (e.g., NFS file stores) or databases (e.g., COINS, XNAT) for storage and retrieval. The resulting performance from these approaches is, however, impeded by standard network switches since they can saturate network bandwidth during transfer from storage to processing nodes for even moderate-sized studies. To that end, a cloud-based "medical image processing-as-a-service" offers promise in utilizing the ecosystem of Apache Hadoop, which is a flexible framework providing distributed, scalable, fault tolerant storage and parallel computational modules, and HBase, which is a NoSQL database built atop Hadoop's distributed file system. Despite this promise, HBase's load distribution strategy of region split and merge is detrimental to the hierarchical organization of imaging data (e.g., project, subject, session, scan, slice). This paper makes two contributions to address these concerns by describing key cloud engineering principles and technology enhancements we made to the Apache Hadoop ecosystem for medical imaging applications. First, we propose a row-key design for HBase, which is a necessary step that is driven by the hierarchical organization of imaging data. Second, we propose a novel data allocation policy within HBase to strongly enforce collocation of hierarchically related imaging data. The proposed enhancements accelerate data processing by minimizing network usage and localizing processing to machines where the data already exist. Moreover, our approach is amenable to the traditional scan, subject, and project-level analysis procedures, and is compatible with standard command line/scriptable image processing software. Experimental results for an illustrative sample of imaging data reveals that our new HBase policy results in a three-fold time improvement in conversion of classic DICOM to NiFTI file formats when compared with the default HBase region split policy, and nearly a six-fold improvement over a commonly available network file system (NFS) approach even for relatively small file sets. Moreover, file access latency is lower than network attached storage.
Blostein, Freida; Assari, Shervin; Caldwell, Cleopatra Howard
2017-08-01
The research on binge eating has overwhelmingly focused on Whites. We aimed to study gender and ethnic differences in the association between body image dissatisfaction and binge eating in a nationally representative sample of Black adults in the USA. This cross-sectional study used data from the National Survey of American Life (NSAL), 2003-2004. Self-identified Caribbean Black (n = 1621) and African American (3570) adults aged 18 and older were enrolled. The independent variable was body dissatisfaction measured with two items. Using the World Health Organization Composite International Diagnostic Interview (WHO-CIDI), outcome was lifetime binge eating without hierarchy according to the DSM-IV criteria. Covariates included age, socioeconomic factors (i.e., education and marital status), and body mass index. Ethnicity and gender were focal moderators. Logistic regressions were used for data analysis. Despite comparable prevalence of lifetime binge eating (5 vs 4 %, p > 0.05), African Americans reported higher body image dissatisfaction than Caribbean Blacks (36 vs 29 %, p > 0.05). In the pooled sample, body dissatisfaction was a strong predictor of lifetime binge eating disorders. There was a significant interaction (p = 0.039) between ethnicity and body image dissatisfaction on binge eating, suggesting a stronger association between body image dissatisfaction and lifetime binge eating for Caribbean Blacks (OR = 11.65, 95 % 6.89-19.72) than African Americans (OR = 6.72, 95 % CI 3.97-11.37). Gender did not interact with body image dissatisfaction on binge eating. Ethnic variation in the link between body image dissatisfaction and binge eating may be due to within-race cultural differences in body image between African Americans and Caribbean Blacks. This may include different definitions, norms, and expectations regarding the body size. Findings suggest that ethnicity may bias relevance of body image dissatisfaction as a diagnostic criterion for binge eating disorders among diverse populations of Blacks.
NASA Astrophysics Data System (ADS)
Heilbronner, Renée; Kilian, Ruediger
2017-04-01
Grain size analyses are carried out for a number of reasons, for example, the dynamically recrystallized grain size of quartz is used to assess the flow stresses during deformation. Typically a thin section or polished surface is used. If the expected grain size is large enough (10 µm or larger), the images can be obtained on a light microscope, if the grain size is smaller, the SEM is used. The grain boundaries are traced (the process is called segmentation and can be done manually or via image processing) and the size of the cross sectional areas (segments) is determined. From the resulting size distributions, 'the grain size' or 'average grain size', usually a mean diameter or similar, is derived. When carrying out such grain size analyses, a number of aspects are critical for the reproducibility of the result: the resolution of the imaging equipment (light microscope or SEM), the type of images that are used for segmentation (cross polarized, partial or full orientation images, CIP versus EBSD), the segmentation procedure (algorithm) itself, the quality of the segmentation and the mathematical definition and calculation of 'the average grain size'. The quality of the segmentation depends very strongly on the criteria that are used for identifying grain boundaries (for example, angles of misorientation versus shape considerations), on pre- and post-processing (filtering) and on the quality of the recorded images (most notably on the indexing ratio). In this contribution, we consider experimentally deformed Black Hills quartzite with dynamically re-crystallized grain sizes in the range of 2 - 15 µm. We compare two basic methods of segmentations of EBSD maps (orientation based versus shape based) and explore how the choice of methods influences the result of the grain size analysis. We also compare different measures for grain size (mean versus mode versus RMS, and 2D versus 3D) in order to determine which of the definitions of 'average grain size yields the most stable results.
Digital holographic image fusion for a larger size object using compressive sensing
NASA Astrophysics Data System (ADS)
Tian, Qiuhong; Yan, Liping; Chen, Benyong; Yao, Jiabao; Zhang, Shihua
2017-05-01
Digital holographic imaging fusion for a larger size object using compressive sensing is proposed. In this method, the high frequency component of the digital hologram under discrete wavelet transform is represented sparsely by using compressive sensing so that the data redundancy of digital holographic recording can be resolved validly, the low frequency component is retained totally to ensure the image quality, and multiple reconstructed images with different clear parts corresponding to a laser spot size are fused to realize the high quality reconstructed image of a larger size object. In addition, a filter combing high-pass and low-pass filters is designed to remove the zero-order term from a digital hologram effectively. The digital holographic experimental setup based on off-axis Fresnel digital holography was constructed. The feasible and comparative experiments were carried out. The fused image was evaluated by using the Tamura texture features. The experimental results demonstrated that the proposed method can improve the processing efficiency and visual characteristics of the fused image and enlarge the size of the measured object effectively.
Camera system resolution and its influence on digital image correlation
Reu, Phillip L.; Sweatt, William; Miller, Timothy; ...
2014-09-21
Digital image correlation (DIC) uses images from a camera and lens system to make quantitative measurements of the shape, displacement, and strain of test objects. This increasingly popular method has had little research on the influence of the imaging system resolution on the DIC results. This paper investigates the entire imaging system and studies how both the camera and lens resolution influence the DIC results as a function of the system Modulation Transfer Function (MTF). It will show that when making spatial resolution decisions (including speckle size) the resolution limiting component should be considered. A consequence of the loss ofmore » spatial resolution is that the DIC uncertainties will be increased. This is demonstrated using both synthetic and experimental images with varying resolution. The loss of image resolution and DIC accuracy can be compensated for by increasing the subset size, or better, by increasing the speckle size. The speckle-size and spatial resolution are now a function of the lens resolution rather than the more typical assumption of the pixel size. The study will demonstrate the tradeoffs associated with limited lens resolution.« less
Uusberg, Helen; Peet, Krista; Uusberg, Andero; Akkermann, Kirsti
2018-03-17
Appearance-related attention biases are thought to contribute to body image disturbances. We investigated how preoccupation with body image is associated with attention biases to body size, focusing on the role of social comparison processes and automaticity. Thirty-six women varying on self-reported preoccupation compared their actual body size to size-modified images of either themselves or a figure-matched peer. Amplification of earlier (N170, P2) and later (P3, LPP) ERP components recorded under low vs. high concurrent working memory load were analyzed. Women with high preoccupation exhibited an earlier bias to larger bodies of both self and peer. During later processing stages, they exhibited a stronger bias to enlarged as well as reduced self-images and a lack of sensitivity to size-modifications of the peer-image. Working memory load did not affect these biases systematically. Current findings suggest that preoccupation with body image involves an earlier attention bias to weight increase cues and later over-engagement with own figure. Copyright © 2018 Elsevier B.V. All rights reserved.
Kim, D H; MacKinnon, T
2018-05-01
To identify the extent to which transfer learning from deep convolutional neural networks (CNNs), pre-trained on non-medical images, can be used for automated fracture detection on plain radiographs. The top layer of the Inception v3 network was re-trained using lateral wrist radiographs to produce a model for the classification of new studies as either "fracture" or "no fracture". The model was trained on a total of 11,112 images, after an eightfold data augmentation technique, from an initial set of 1,389 radiographs (695 "fracture" and 694 "no fracture"). The training data set was split 80:10:10 into training, validation, and test groups, respectively. An additional 100 wrist radiographs, comprising 50 "fracture" and 50 "no fracture" images, were used for final testing and statistical analysis. The area under the receiver operator characteristic curve (AUC) for this test was 0.954. Setting the diagnostic cut-off at a threshold designed to maximise both sensitivity and specificity resulted in values of 0.9 and 0.88, respectively. The AUC scores for this test were comparable to state-of-the-art providing proof of concept for transfer learning from CNNs in fracture detection on plain radiographs. This was achieved using only a moderate sample size. This technique is largely transferable, and therefore, has many potential applications in medical imaging, which may lead to significant improvements in workflow productivity and in clinical risk reduction. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Deng, Shengming; Zhang, Wei; Zhang, Bin; Hong, Ruoyu; Chen, Qing; Dong, Jiajia; Chen, Yinyiin; Chen, Zhiqiang; Wu, Yiwei
2015-01-01
Ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) modified with a novel cyclic arginine-glycine-aspartate (RGD) peptide were made and radiolabeled as single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) dual-modality agents for imaging of breast cancer. The probe was tested both in vitro and in vivo to determine its receptor targeting efficacy and feasibility for SPECT and MRI. The radiochemical syntheses of 125I-cRGD-USPIO were accomplished with a radiochemical purity of 96.05 ± 0.33 %. High radiochemical stability was found in fresh human serum and in phosphate-buffered saline. The average hydrodynamic size of 125I-cRGD-USPIO determined by dynamic light scattering was 51.3 nm. Results of in vitro experiments verified the specificity of the radiolabeled nanoparticles to tumor cells. Preliminary biodistribution studies of 125I-radiolabeled cRGD-USPIO in Bcap37-bearing nude mice showed that it had long circulation half-life, high tumor uptake, and high initial blood retention with moderate liver uptake. In vivo tumor targeting and uptake of the radiolabeled nanoparticles in mice model were visualized by SPECT and MRI collected at different time points. Our results strongly indicated that the 125I-cRGD-USPIO could be used as a promising bifunctional radiotracer for early clinical tumor detection with high sensitivity and high spatial resolution by SPECT and MRI.
A simple autocorrelation algorithm for determining grain size from digital images of sediment
Rubin, D.M.
2004-01-01
Autocorrelation between pixels in digital images of sediment can be used to measure average grain size of sediment on the bed, grain-size distribution of bed sediment, and vertical profiles in grain size in a cross-sectional image through a bed. The technique is less sensitive than traditional laboratory analyses to tails of a grain-size distribution, but it offers substantial other advantages: it is 100 times as fast; it is ideal for sampling surficial sediment (the part that interacts with a flow); it can determine vertical profiles in grain size on a scale finer than can be sampled physically; and it can be used in the field to provide almost real-time grain-size analysis. The technique can be applied to digital images obtained using any source with sufficient resolution, including digital cameras, digital video, or underwater digital microscopes (for real-time grain-size mapping of the bed). ?? 2004, SEPM (Society for Sedimentary Geology).
Hologram generation by horizontal scanning of a high-speed spatial light modulator.
Takaki, Yasuhiro; Okada, Naoya
2009-06-10
In order to increase the image size and the viewing zone angle of a hologram, a high-speed spatial light modulator (SLM) is imaged as a vertically long image by an anamorphic imaging system, and this image is scanned horizontally by a galvano scanner. The reduction in horizontal pixel pitch of the SLM provides a wide viewing zone angle. The increased image height and horizontal scanning increased the image size. We demonstrated the generation of a hologram having a 15 degrees horizontal viewing zone angle and an image size of 3.4 inches with a frame rate of 60 Hz using a digital micromirror device with a frame rate of 13.333 kHz as a high-speed SLM.
The Effect of Camera Angle and Image Size on Source Credibility and Interpersonal Attraction.
ERIC Educational Resources Information Center
McCain, Thomas A.; Wakshlag, Jacob J.
The purpose of this study was to examine the effects of two nonverbal visual variables (camera angle and image size) on variables developed in a nonmediated context (source credibility and interpersonal attraction). Camera angle and image size were manipulated in eight video taped television newscasts which were subsequently presented to eight…
Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C; Varma, Rohit
2016-08-01
To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76-0.80). Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy.
Comparison of four moderate-size earthquakes in southern California using seismology and InSAR
Mellors, R.J.; Magistrale, H.; Earle, P.; Cogbill, A.H.
2004-01-01
Source parameters determined from interferometric synthetic aperture radar (InSAR) measurements and from seismic data are compared from four moderate-size (less than M 6) earthquakes in southern California. The goal is to verify approximate detection capabilities of InSAR, assess differences in the results, and test how the two results can be reconciled. First, we calculated the expected surface deformation from all earthquakes greater than magnitude 4 in areas with available InSAR data (347 events). A search for deformation from the events in the interferograms yielded four possible events with magnitudes less than 6. The search for deformation was based on a visual inspection as well as cross-correlation in two dimensions between the measured signal and the expected signal. A grid-search algorithm was then used to estimate focal mechanism and depth from the InSAR data. The results were compared with locations and focal mechanisms from published catalogs. An independent relocation using seismic data was also performed. The seismic locations fell within the area of the expected rupture zone for the three events that show clear surface deformation. Therefore, the technique shows the capability to resolve locations with high accuracy and is applicable worldwide. The depths determined by InSAR agree with well-constrained seismic locations determined in a 3D velocity model. Depth control for well-imaged shallow events using InSAR data is good, and better than the seismic constraints in some cases. A major difficulty for InSAR analysis is the poor temporal coverage of InSAR data, which may make it impossible to distinguish deformation due to different earthquakes at the same location.
The effect of defect cluster size and interpolation on radiographic image quality
NASA Astrophysics Data System (ADS)
Töpfer, Karin; Yip, Kwok L.
2011-03-01
For digital X-ray detectors, the need to control factory yield and cost invariably leads to the presence of some defective pixels. Recently, a standard procedure was developed to identify such pixels for industrial applications. However, no quality standards exist in medical or industrial imaging regarding the maximum allowable number and size of detector defects. While the answer may be application specific, the minimum requirement for any defect specification is that the diagnostic quality of the images be maintained. A more stringent criterion is to keep any changes in the images due to defects below the visual threshold. Two highly sensitive image simulation and evaluation methods were employed to specify the fraction of allowable defects as a function of defect cluster size in general radiography. First, the most critical situation of the defect being located in the center of the disease feature was explored using image simulation tools and a previously verified human observer model, incorporating a channelized Hotelling observer. Detectability index d' was obtained as a function of defect cluster size for three different disease features on clinical lung and extremity backgrounds. Second, four concentrations of defects of four different sizes were added to clinical images with subtle disease features and then interpolated. Twenty observers evaluated the images against the original on a single display using a 2-AFC method, which was highly sensitive to small changes in image detail. Based on a 50% just-noticeable difference, the fraction of allowed defects was specified vs. cluster size.
Digital 3D holographic display using scattering layers for enhanced viewing angle and image size
NASA Astrophysics Data System (ADS)
Yu, Hyeonseung; Lee, KyeoReh; Park, Jongchan; Park, YongKeun
2017-05-01
In digital 3D holographic displays, the generation of realistic 3D images has been hindered by limited viewing angle and image size. Here we demonstrate a digital 3D holographic display using volume speckle fields produced by scattering layers in which both the viewing angle and the image size are greatly enhanced. Although volume speckle fields exhibit random distributions, the transmitted speckle fields have a linear and deterministic relationship with the input field. By modulating the incident wavefront with a digital micro-mirror device, volume speckle patterns are controlled to generate 3D images of micrometer-size optical foci with 35° viewing angle in a volume of 2 cm × 2 cm × 2 cm.
Coelho, Carolina G.; Giatti, Luana; Molina, Maria D. C. B.; Nunes, Maria A. A.; Barreto, Sandhi M.
2015-01-01
The association of body image dissatisfaction and obesity with physical activity is likely to differ according to gender. To investigate this hypothesis, we conducted a cross-sectional study among the ELSA-Brasil cohort members aged 34–65 years (n = 13,286). The body image dissatisfaction was present even among normal weight individuals of both sexes and was associated with lesser chances of practicing moderate physical activity in women and intense physical activity in men. Men and women with central obesity were less prone to practice physical activity of high or moderate intensity. Overweight and obese men were more likely to report vigorous physical activity while obese women were less likely to report this level of physical activity. Body images as well as nutritional status are related to physical activity in both sexes, but the association with physical activity differs by gender. PMID:26035664
Halliwell, Emma; Dittmar, Helga; Orsborn, Amber
2007-09-01
This study examines the effects of exposure to the muscular male body ideal on body-focused negative affect among male gym users and non-exercisers. As hypothesized, the impact of media exposure depended on men's exercise status. Non-exercisers (n = 58) reported greater body-focused negative affect after exposure to images of muscular male models than after neutral images (no model controls), whereas gym users (n = 58) showed a tendency for less body-focused negative affect after the model images than after the control images. Furthermore, the extent to which gym users were motivated to increase strength and muscularity moderated these exposure effects; men who reported stronger strength and muscularity exercise motivation reported a greater degree of self-enhancement after exposure to the muscular ideal. The findings are interpreted with respect to likely differences in motives for social comparisons.
Coelho, Carolina G; Giatti, Luana; Molina, Maria D C B; Nunes, Maria A A; Barreto, Sandhi M
2015-05-29
The association of body image dissatisfaction and obesity with physical activity is likely to differ according to gender. To investigate this hypothesis, we conducted a cross-sectional study among the ELSA-Brasil cohort members aged 34-65 years (n=13,286). The body image dissatisfaction was present even among normal weight individuals of both sexes and was associated with lesser chances of practicing moderate physical activity in women and intense physical activity in men. Men and women with central obesity were less prone to practice physical activity of high or moderate intensity. Overweight and obese men were more likely to report vigorous physical activity while obese women were less likely to report this level of physical activity. Body images as well as nutritional status are related to physical activity in both sexes, but the association with physical activity differs by gender.
Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-01-01
Abstract. Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue–air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo. PMID:23235834
NASA Astrophysics Data System (ADS)
Unglert, Carolin I.; Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-12-01
Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue-air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo.
The correlation of social support with mental health: A meta-analysis.
Harandi, Tayebeh Fasihi; Taghinasab, Maryam Mohammad; Nayeri, Tayebeh Dehghan
2017-09-01
Social support is an important factor that can affect mental health. In recent decades, many studies have been done on the impact of social support on mental health. The purpose of the present study is to investigate the effect size of the relationship between social support and mental health in studies in Iran. This meta-analysis was carried out in studies that were performed from 1996 through 2015. Databases included SID and Magiran, the comprehensive portal of human sciences, Noor specialized magazine databases, IRANDOC, Proquest, PubMed, Scopus, ERIC, Iranmedex and Google Scholar. The keywords used to search these websites included "mental health or general health," and "Iran" and "social support." In total, 64 studies had inclusion criteria meta-analysis. In order to collect data used from a meta-analysis worksheet that was made by the researcher and for data analysis software, CMA-2 was used. The mean of effect size of the 64 studies in the fixed-effect model and random-effect model was obtained respectively as 0.356 and 0.330, which indicated the moderate effect size of social support on mental health. The studies did not have publication bias, and enjoyed a heterogeneous effect size. The target population and social support questionnaire were moderator variables, but sex, sampling method, and mental health questionnaire were not moderator variables. Regarding relatively high effect size of the correlation between social support and mental health, it is necessary to predispose higher social support, especially for women, the elderly, patients, workers, and students.
A Guide to Analysing Tongue Motion from Ultrasound Images
ERIC Educational Resources Information Center
Stone, Maureen
2005-01-01
This paper is meant to be an introduction to and general reference for ultrasound imaging for new and moderately experienced users of the instrument. The paper consists of eight sections. The first explains how ultrasound works, including beam properties, scan types and machine features. The second section discusses image quality, including the…
Kim, David M.; Zhang, Hairong; Zhou, Haiying; Du, Tommy; Wu, Qian; Mockler, Todd C.; Berezin, Mikhail Y.
2015-01-01
The optical signature of leaves is an important monitoring and predictive parameter for a variety of biotic and abiotic stresses, including drought. Such signatures derived from spectroscopic measurements provide vegetation indices – a quantitative method for assessing plant health. However, the commonly used metrics suffer from low sensitivity. Relatively small changes in water content in moderately stressed plants demand high-contrast imaging to distinguish affected plants. We present a new approach in deriving sensitive indices using hyperspectral imaging in a short-wave infrared range from 800 nm to 1600 nm. Our method, based on high spectral resolution (1.56 nm) instrumentation and image processing algorithms (quantitative histogram analysis), enables us to distinguish a moderate water stress equivalent of 20% relative water content (RWC). The identified image-derived indices 15XX nm/14XX nm (i.e. 1529 nm/1416 nm) were superior to common vegetation indices, such as WBI, MSI, and NDWI, with significantly better sensitivity, enabling early diagnostics of plant health. PMID:26531782
Ravaja, Niklas
2004-01-01
We examined the moderating influence of dispositional behavioral inhibition system and behavioral activation system (BAS) sensitivities, Negative Affect, and Positive Affect on the relationship between a small moving vs. static facial image and autonomic responses when viewing/listening to news messages read by a newscaster among 36 young adults. Autonomic parameters measured were respiratory sinus arrhythmia (RSA), low-frequency (LF) component of heart rate variability (HRV), electrodermal activity, and pulse transit time (PTT). The results showed that dispositional BAS sensitivity, particularly BAS Fun Seeking, and Negative Affect interacted with facial image motion in predicting autonomic nervous system activity. A moving facial image was related to lower RSA and LF component of HRV and shorter PTTs as compared to a static facial image among high BAS individuals. Even a small talking facial image may contribute to sustained attentional engagement among high BAS individuals, given that the BAS directs attention toward the positive cue and a moving social stimulus may act as a positive incentive for high BAS individuals.
Information retrieval based on single-pixel optical imaging with quick-response code
NASA Astrophysics Data System (ADS)
Xiao, Yin; Chen, Wen
2018-04-01
Quick-response (QR) code technique is combined with ghost imaging (GI) to recover original information with high quality. An image is first transformed into a QR code. Then the QR code is treated as an input image in the input plane of a ghost imaging setup. After measurements, traditional correlation algorithm of ghost imaging is utilized to reconstruct an image (QR code form) with low quality. With this low-quality image as an initial guess, a Gerchberg-Saxton-like algorithm is used to improve its contrast, which is actually a post processing. Taking advantage of high error correction capability of QR code, original information can be recovered with high quality. Compared to the previous method, our method can obtain a high-quality image with comparatively fewer measurements, which means that the time-consuming postprocessing procedure can be avoided to some extent. In addition, for conventional ghost imaging, the larger the image size is, the more measurements are needed. However, for our method, images with different sizes can be converted into QR code with the same small size by using a QR generator. Hence, for the larger-size images, the time required to recover original information with high quality will be dramatically reduced. Our method makes it easy to recover a color image in a ghost imaging setup, because it is not necessary to divide the color image into three channels and respectively recover them.
Fang, Jui; Zhou, Zhuhuang; Chang, Ning-Fang; Wan, Yung-Liang; Tsui, Po-Hsiang
2018-07-01
Hepatic steatosis is an abnormal state where excess lipid mass is accumulated in hepatocyte vesicles. Backscattered ultrasound signals received from the liver contain useful information regarding the degree of steatosis in the liver. The homodyned-K (HK) distribution has been demonstrated as a general model for ultrasound backscattering. The estimator based on the first three integer moments (denoted as "FTM") of the intensity has potential for practical applications because of its simplicity and low computational complexity. This study explored the diagnostic performance of HK parametric imaging based on the FTM method in the assessment of hepatic steatosis. Phantom experiments were initially conducted using the sliding window technique to determine an appropriate window size length (WSL) for HK parametric imaging. Subsequently, hepatic steatosis was induced in male Wistar rats fed a methionine- and choline-deficient (MCD) diet for 0 (i.e., normal control), 1, 2, 4, 6, and 8 weeks (n = 36; six rats in each group). After completing the scheduled MCD diet, ultrasound B-mode and HK imaging of the rat livers were performed in vivo and histopathological examinations were conducted to score the degree of hepatic steatosis. HK parameters μ (related to scatterer number density) and k (related to scatterer periodicity) were expressed as functions of the steatosis stage in terms of the median and interquartile range (IQR). Receiver operating characteristic (ROC) curve analysis was conducted to assess the diagnostic performance levels of the μ and k parameters. The results showed that an appropriate WSL for HK parametric imaging is seven times the pulse length of the transducer. The median value of the μ parameter increased monotonically from 0.194 (IQR: 0.18-0.23) to 0.893 (IQR: 0.64-1.04) as the steatosis stage increased. Concurrently, the median value of the k parameter increased from 0.279 (IQR: 0.26-0.31) to 0.5 (IQR: 0.41-0.54) in the early stages (normal to mild) and decreased to 0.39 (IQR: 0.29-0.45) in the advanced stages (moderate to severe). The areas under the ROC curves obtained using (μ, k) were (0.947, 0.804), (0.914, 0.575), and (0.813, 0.604) for the steatosis stages of ≥mild, ≥moderate, and ≥severe, respectively. The current findings suggest that ultrasound HK parametric imaging based on FTM estimation has great potential for future clinical diagnoses of hepatic steatosis. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zoran, Maria A.; Savastru, Roxana S.; Savastru, Dan M.
2015-10-01
With the increasing industrialization and urbanization, especially in the metropolis regions, aerosol pollution has highly negative effects on environment. Urbanization is responsible of three major changes that may have impact on the urban atmosphere: replacement of the natural surfaces with buildings and impermeable pavements, heat of anthropogenic origin and air pollution. The importance of aerosols for radiative and atmospheric chemical processes is widely recognized. They can scatter and/or absorb solar radiation leading to changes of the radiation budget. Also, the so-called indirect effect of aerosols describes the cloud-aerosol interactions, which can modify the chemical and physical processes in the atmosphere. Their high spatial variability and short lifetime make spaceborne sensors especially well suited for their observation. Remote sensing is a key application in global-change science and urban climatology. Since the launch of the MODerate resolution Imaging Spectroradiometer (MODIS) there is detailed global aerosol information available, both over land and oceans The aerosol parameters can be measured directly in situ or derived from satellite remote sensing observations. All these methods are important and complementary. The objective of this work was to document the seasonal and inter-annual patterns of the aerosol pollution particulate matter in two size fractions (PM10 and PM2.5) loading and air quality index (AQI) over Bucharest metropolitan area in Romania based on in-situ and MODIS (Terra-Moderate Resolution Imaging Spectoradiometer) satellite time series data over 2010-2012 period. Accurate information of urban air pollution is required for environmental and health policy, but also to act as a basis for designing and stratifying future monitoring networks.
Ionization Injection of Electrons into a Plasma Wakefield Accelerator at FACET
NASA Astrophysics Data System (ADS)
Clayton, Chris; E-200 At Facet Collaboration
2013-10-01
In the PWFA experiments at FACET, a low ionization-potential (IP) metal vapor gas (Li) is confined within a heat-pipe oven by a higher IP buffer gas (typically He). The Li is easily field-ionized by the FACET beam. A non-linear wake is formed in the blowout regime when the 20.3 GeV bunch containing 2e10 electrons in a σz ~ 30 μm is focused to a (vacuum) σr < 25 near the ~ 10cm-long boundary region. There the Li density rises from zero up to the oven's 30cm-long flat-topped density of 2.5e17 cm-3. To obtain a mono-energetic beam from accelerated ionization-injected electrons at the far end of the oven--the goal of this experiment--it is necessary for the FACET beam to have a betatron pinch just where the flat-topped region begins; i.e., where the wake wavelength is no longer changing. If the buffer gas contains a mixture of He and a moderate IP gas, the ``impurity'' gases will also be field ionized and potentially contribute more charge to the injected bunch than with He alone. Moderate IP gases were added to the He buffer gas: 10%, 20%, and 50% Ar (balance He) and 30% Ne (balance He) have been used. Evidence for ionization injection and acceleration appears through the observation of distinct features, characterized by their very narrow size and thus angular spread, at the image plane of a magnetic imaging spectrometer. Analysis aimed at characterizing these features with respect to energy, charge, and angular spread is underway and will be presented. This work was supported by the DOE and the NSF.
Marsh, Herbert W; Hau, K T; Sung, R Y T; Yu, C W
2007-05-01
Childhood obesity is increasingly prevalent in Western and non-Western societies. The authors related multiple dimensions of physical self-concept to body composition for 763 Chinese children aged 8 to 15 and compared the results with Western research. Compared with Western research, gender differences favoring boys were generally much smaller for physical self-concept and body image. Objective and subjective indexes of body fat were negatively related to many components of physical self-concept, but--in contrast to Western research--were unrelated to global self-esteem and slightly positively related to health self-concept. In support of discrepancy theory, actual-ideal discrepancies in body image were related to physical self-concept. However, consistent with the Chinese cultural value of moderation, and in contrast to Western results, being too thin relative to personal ideals was almost as detrimental as being too fat. The results reflect stronger Chinese cultural values of moderation and acceptance of obesity than in Western culture and have implications for social and educational policy in China. Copyright (c) 2007 APA, all rights reserved.
Photogrammetric Processing Using ZY-3 Satellite Imagery
NASA Astrophysics Data System (ADS)
Kornus, W.; Magariños, A.; Pla, M.; Soler, E.; Perez, F.
2015-03-01
This paper evaluates the stereoscopic capacities of the Chinese sensor ZiYuan-3 (ZY-3) for the generation of photogrammetric products. The satellite was launched on January 9, 2012 and carries three high-resolution panchromatic cameras viewing in forward (22º), nadir (0º) and backward direction (-22º) and an infrared multi-spectral scanner (IRMSS), which is slightly looking forward (6º). The ground sampling distance (GSD) is 2.1m for the nadir image, 3.5m for the two oblique stereo images and 5.8m for the multispectral image. The evaluated ZY-3 imagery consists of a full set of threefold-stereo and a multi-spectral image covering an area of ca. 50km x 50km north-west of Barcelona, Spain. The complete photogrammetric processing chain was executed including image orientation, the generation of a digital surface model (DSM), radiometric image correction, pansharpening, orthoimage generation and digital stereo plotting. All 4 images are oriented by estimating affine transformation parameters between observed and nominal RPC (rational polynomial coefficients) image positions of 17 ground control points (GCP) and a subsequent calculation of refined RPC. From 10 independent check points RMS errors of 2.2m, 2.0m and 2.7m in X, Y and H are obtained. Subsequently, a DSM of 5m grid spacing is generated fully automatically. A comparison with the Lidar data results in an overall DSM accuracy of approximately 3m. In moderate and flat terrain higher accuracies in the order of 2.5m and better are achieved. In a next step orthoimages from the high resolution nadir image and the multispectral image are generated using the refined RPC geometry and the DSM. After radiometric corrections a fused high resolution colour orthoimage with 2.1m pixel size is created using an adaptive HSL method. The pansharpen process is performed after the individual geocorrection due to the different viewing angles between the two images. In a detailed analysis of the colour orthoimage artifacts are detected covering an area of 4691ha, corresponding to less than 2% of the imaged area. Most of the artifacts are caused by clouds (4614ha). A minor part (77ha) is affected by colour patch, stripping or blooming effects. For the final qualitative analysis on the usability of the ZY-3 imagery for stereo plotting purposes stereo combinations of the nadir and an oblique image are discarded, mainly due to the different pixel size, which produces difficulties in the stereoscopic vision and poor accuracy in positioning and measuring. With the two oblique images a level of detail equivalent to 1:25.000 scale is achieved for transport network, hydrography, vegetation and elements to model the terrain as break lines. For settlement, including buildings and other constructions a lower level of detail is achieved equivalent to 1:50.000 scale.
Computation of Effect Size for Moderating Effects of Categorical Variables in Multiple Regression
ERIC Educational Resources Information Center
Aguinis, Herman; Pierce, Charles A.
2006-01-01
The computation and reporting of effect size estimates is becoming the norm in many journals in psychology and related disciplines. Despite the increased importance of effect sizes, researchers may not report them or may report inaccurate values because of a lack of appropriate computational tools. For instance, Pierce, Block, and Aguinis (2004)…
Jayaprakash, Paul T
2017-09-01
Often cited reliability test on video superimposition method integrated scaling face-images in relation to skull-images, tragus-auditory meatus relationship in addition to exocanthion-Whitnall's tubercle relationship when orientating the skull-image and wipe mode imaging in addition to mix mode imaging when obtaining skull-face image overlay and evaluating the goodness of match. However, a report that found higher false positive matches in computer assisted superimposition method transited from the above foundational concepts and relied on images of unspecified sizes that are lesser than 'life-size', frontal plane landmarks in the skull- and face- images alone for orientating the skull-image and mix images alone for evaluating the goodness of match. Recently, arguing the use of 'life-size' images as 'archaic', the authors who tested the reliability in the computer assisted superimposition method have denied any method transition. This article describes that the use of images of unspecified sizes at lesser than 'life-size' eliminates the only possibility to quantify parameters during superimposition which alone enables dynamic skull orientation when overlaying a skull-image with a face-image in an anatomically acceptable orientation. The dynamic skull orientation process mandatorily requires aligning the tragus in the 2D face-image with the auditory meatus in the 3D skull-image for anatomically orientating the skull-image in relation to the posture in the face-image, a step not mentioned by the authors describing the computer assisted superimposition method. Furthermore, mere reliance on mix type images during image overlay eliminates the possibility to assess the relationship between the leading edges of the skull- and face-image outlines as also specific area match among the corresponding craniofacial organs during superimposition. Indicating the possibility of increased false positive matches as a consequence of the above method transitions, the need for testing the reliability in the superimposition method adopting concepts that are considered safe is stressed. Copyright © 2017 Elsevier B.V. All rights reserved.
Terslev, Lene; Gutierrez, Marwin; Schmidt, Wolfgang A; Keen, Helen I; Filippucci, Emilio; Kane, David; Thiele, Ralf; Kaeley, Gurjit; Balint, Peter; Mandl, Peter; Delle Sedie, Andrea; Hammer, Hilde Berner; Christensen, Robin; Möller, Ingrid; Pineda, Carlos; Kissin, Eugene; Bruyn, George A; Iagnocco, Annamaria; Naredo, Esperanza; D'Agostino, Maria Antonietta
2015-11-01
To summarize the work performed by the Outcome Measures in Rheumatology (OMERACT) Ultrasound (US) Working Group on the validation of US as a potential outcome measure in gout. Based on the lack of definitions, highlighted in a recent literature review on US as an outcome tool in gout, a series of iterative exercises were carried out to obtain consensus-based definitions on US elementary components in gout using a Delphi exercise and subsequently testing these definitions in static images and in patients with proven gout. Cohen's κ was used to test agreement, and values of 0-0.20 were considered poor, 0.20-0.40 fair, 0.40-0.60 moderate, 0.60-0.80 good, and 0.80-1 excellent. With an agreement of > 80%, consensus-based definitions were obtained for the 4 elementary lesions highlighted in the literature review: tophi, aggregates, erosions, and double contour (DC). In static images interobserver reliability ranged from moderate to almost perfect, and similar results were found for the intrareader reliability. In patients the intraobserver agreement was good for all lesions except DC (moderate). The interobserver agreement was poor for aggregates and DC but moderate for the other components. These first steps in evaluating the validity of US as an outcome measure for gout show that the reliability of the definitions ranged from moderate to excellent in static images and somewhat lower in patients, indicating that a standardized scanning technique may be needed, before testing the responsiveness of those definitions in a composite US score.
The Floe Size Distribution in the Marginal Ice Zone of the Beaufort and Chukchi Seas
NASA Astrophysics Data System (ADS)
Schweiger, A. J. B.; Stern, H. L., III; Stark, M.; Zhang, J.; Steele, M.; Hwang, P. B.
2014-12-01
Several key processes in the Marginal Ice Zone (MIZ) of the Arctic Ocean are related to the size of the ice floes, whose diameters range from meters to tens of kilometers. The floe size distribution (FSD) influences the mechanical properties of the ice cover, air-sea momentum and heat transfer, lateral melting, and light penetration. However, no existing sea-ice/ocean models currently simulate the FSD in the MIZ. Model development depends on observations of the FSD for parameterization, calibration, and validation. To support the development and implementation of the FSD in the Marginal Ice Zone Modeling and Assimilation System (MIZMAS), we have analyzed the FSD in the Beaufort and Chukchi seas using multiple sources of satellite imagery: NASA's Moderate Resolution Imaging Spectroradiometer (MODIS) on the Terra and Aqua satellites (250 m pixel size), the USGS Landsat 8 satellite (80 m pixel size), the Canadian Space Agency's synthetic aperture radar (SAR) on RADARSAT (50 meter pixel size), and declassified National Technical Means imagery from the Global Fiducials Library (GFL) of the USGS (1 m pixel size). The procedure for identifying ice floes in the imagery begins with manually delineating cloud-free regions (if necessary). A threshold is then chosen to separate ice from water. Morphological operations and other semi-automated techniques are used to identify individual floes, whose properties are then easily calculated. We use the mean caliper diameter as the measure of floe size. The FSD is adequately described by a power-law in which the exponent characterizes the relative number of large and small floes. Changes in the exponent over time and space reflect changes in physical processes in the MIZ, such as sea-ice deformation, fracturing, and melting. We report results of FSD analysis for the spring and summer of 2013 and 2014, and show how the FSD will be incorporated into the MIZMAS model.
Significance of the impact of motion compensation on the variability of PET image features
NASA Astrophysics Data System (ADS)
Carles, M.; Bach, T.; Torres-Espallardo, I.; Baltas, D.; Nestle, U.; Martí-Bonmatí, L.
2018-03-01
In lung cancer, quantification by positron emission tomography/computed tomography (PET/CT) imaging presents challenges due to respiratory movement. Our primary aim was to study the impact of motion compensation implied by retrospectively gated (4D)-PET/CT on the variability of PET quantitative parameters. Its significance was evaluated by comparison with the variability due to (i) the voxel size in image reconstruction and (ii) the voxel size in image post-resampling. The method employed for feature extraction was chosen based on the analysis of (i) the effect of discretization of the standardized uptake value (SUV) on complementarity between texture features (TF) and conventional indices, (ii) the impact of the segmentation method on the variability of image features, and (iii) the variability of image features across the time-frame of 4D-PET. Thirty-one PET-features were involved. Three SUV discretization methods were applied: a constant width (SUV resolution) of the resampling bin (method RW), a constant number of bins (method RN) and RN on the image obtained after histogram equalization (method EqRN). The segmentation approaches evaluated were 40% of SUVmax and the contrast oriented algorithm (COA). Parameters derived from 4D-PET images were compared with values derived from the PET image obtained for (i) the static protocol used in our clinical routine (3D) and (ii) the 3D image post-resampled to the voxel size of the 4D image and PET image derived after modifying the reconstruction of the 3D image to comprise the voxel size of the 4D image. Results showed that TF complementarity with conventional indices was sensitive to the SUV discretization method. In the comparison of COA and 40% contours, despite the values not being interchangeable, all image features showed strong linear correlations (r > 0.91, p\\ll 0.001 ). Across the time-frames of 4D-PET, all image features followed a normal distribution in most patients. For our patient cohort, the compensation of tumor motion did not have a significant impact on the quantitative PET parameters. The variability of PET parameters due to voxel size in image reconstruction was more significant than variability due to voxel size in image post-resampling. In conclusion, most of the parameters (apart from the contrast of neighborhood matrix) were robust to the motion compensation implied by 4D-PET/CT. The impact on parameter variability due to the voxel size in image reconstruction and in image post-resampling could not be assumed to be equivalent.
Enhancing Spatial Resolution of Remotely Sensed Imagery Using Deep Learning
NASA Astrophysics Data System (ADS)
Beck, J. M.; Bridges, S.; Collins, C.; Rushing, J.; Graves, S. J.
2017-12-01
Researchers at the Information Technology and Systems Center at the University of Alabama in Huntsville are using Deep Learning with Convolutional Neural Networks (CNNs) to develop a method for enhancing the spatial resolutions of moderate resolution (10-60m) multispectral satellite imagery. This enhancement will effectively match the resolutions of imagery from multiple sensors to provide increased global temporal-spatial coverage for a variety of Earth science products. Our research is centered on using Deep Learning for automatically generating transformations for increasing the spatial resolution of remotely sensed images with different spatial, spectral, and temporal resolutions. One of the most important steps in using images from multiple sensors is to transform the different image layers into the same spatial resolution, preferably the highest spatial resolution, without compromising the spectral information. Recent advances in Deep Learning have shown that CNNs can be used to effectively and efficiently upscale or enhance the spatial resolution of multispectral images with the use of an auxiliary data source such as a high spatial resolution panchromatic image. In contrast, we are using both the spatial and spectral details inherent in low spatial resolution multispectral images for image enhancement without the use of a panchromatic image. This presentation will discuss how this technology will benefit many Earth Science applications that use remotely sensed images with moderate spatial resolutions.
On What People Know about Images on Mirrors
ERIC Educational Resources Information Center
Bertamini, Marco; Parks, Theodore E.
2005-01-01
As observed by Gombrich [Gombrich, E. H. (1960). "Art and illusion." Oxford: Phaidon Press], we confirm that most people are unaware of the size of their own image on mirrors. Specifically we have documented the knowledge that people have of the size of their own head and of the size of the mirror image of their own head. In addition we have…
Husarik, Daniela B; Marin, Daniele; Samei, Ehsan; Richard, Samuel; Chen, Baiyu; Jaffe, Tracy A; Bashir, Mustafa R; Nelson, Rendon C
2012-08-01
The aim of this study was to compare the image quality of abdominal computed tomography scans in an anthropomorphic phantom acquired at different radiation dose levels where each raw data set is reconstructed with both a standard convolution filtered back projection (FBP) and a full model-based iterative reconstruction (MBIR) algorithm. An anthropomorphic phantom in 3 sizes was used with a custom-built liver insert simulating late hepatic arterial enhancement and containing hypervascular liver lesions of various sizes. Imaging was performed on a 64-section multidetector-row computed tomography scanner (Discovery CT750 HD; GE Healthcare, Waukesha, WI) at 3 different tube voltages for each patient size and 5 incrementally decreasing tube current-time products for each tube voltage. Quantitative analysis consisted of contrast-to-noise ratio calculations and image noise assessment. Qualitative image analysis was performed by 3 independent radiologists rating subjective image quality and lesion conspicuity. Contrast-to-noise ratio was significantly higher and mean image noise was significantly lower on MBIR images than on FBP images in all patient sizes, at all tube voltage settings, and all radiation dose levels (P < 0.05). Overall image quality and lesion conspicuity were rated higher for MBIR images compared with FBP images at all radiation dose levels. Image quality and lesion conspicuity on 25% to 50% dose MBIR images were rated equal to full-dose FBP images. This phantom study suggests that depending on patient size, clinically acceptable image quality of the liver in the late hepatic arterial phase can be achieved with MBIR at approximately 50% lower radiation dose compared with FBP.
Body self-discrepancies and women's social physique anxiety: the moderating role of the feared body.
Woodman, Tim; Steer, Rebecca
2011-05-01
We explored ideal, ought, and feared body image self-discrepancies as predictors of social physique anxiety within Carver, Lawrence, and Scheier's and Woodman and Hemmings' interaction frameworks. One hundred women completed actual, ideal, ought, and feared body self-discrepancy visual analogue scales, the Social Physique Anxiety Scale and the Beck Depression Inventory-II. Moderated hierarchical regression analyses indicated that the relationship between ought body fat discrepancies and social physique anxiety was moderated by proximity to the feared fat self. Specifically, the positive relationship between ought fat discrepancies and social physique anxiety was stronger when women were far from their feared body self. The results highlight the importance of considering the feared self in order to more fully understand the relationship between body image and social physique anxiety. ©2010 The British Psychological Society.
Uribe, S; Rojas, LA; Rosas, CF
2013-01-01
The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854
Carlton, Joshua A; Maxwell, Adam W; Bauer, Lyndsey B; McElroy, Sara M; Layfield, Lester J; Ahsan, Humera; Agarwal, Ajay
2017-06-01
Background and purpose In patients with squamous cell carcinoma of the head and neck (HNSCC), extracapsular spread (ECS) of metastases in cervical lymph nodes affects prognosis and therapy. We assessed the accuracy of intravenous contrast-enhanced computed tomography (CT) and the utility of imaging criteria for preoperative detection of ECS in metastatic cervical lymph nodes in patients with HNSCC. Materials and methods Preoperative intravenous contrast-enhanced neck CT images of 93 patients with histopathological HNSCC metastatic nodes were retrospectively assessed by two neuroradiologists for ECS status and ECS imaging criteria. Radiological assessments were compared with histopathological assessments of neck dissection specimens, and interobserver agreement of ECS status and ECS imaging criteria were measured. Results Sensitivity, specificity, positive predictive value, and accuracy for overall ECS assessment were 57%, 81%, 82% and 67% for observer 1, and 66%, 76%, 80% and 70% for observer 2, respectively. Correlating three or more ECS imaging criteria with histopathological ECS increased specificity and positive predictive value, but decreased sensitivity and accuracy. Interobserver agreement for overall ECS assessment demonstrated a kappa of 0.59. Central necrosis had the highest kappa of 0.74. Conclusion CT has moderate specificity for ECS assessment in HNSCC metastatic cervical nodes. Identifying three or more ECS imaging criteria raises specificity and positive predictive value, therefore preoperative identification of multiple criteria may be clinically useful. Interobserver agreement is moderate for overall ECS assessment, substantial for central necrosis. Other ECS CT criteria had moderate agreement at best and therefore should not be used individually as criteria for detecting ECS by CT.
Carotid Stenosis And Ulcer Detectability As A Function Of Pixel Size
NASA Astrophysics Data System (ADS)
Mintz, Leslie J.; Enzmann, Dieter R.; Keyes, Gary S.; Mainiero, Louis M.; Brody, William R.
1981-11-01
Digital radiography, in conjunction with digital subtraction methods can provide high quality images of the vascular system,1-4 Spatial resolution is one important limiting factor of this imaging technique. Since spatial resolution of a digital image is a function of pixel size, it is important to determine the pixel size threshold necessary to provide information comparable to that of conventional angiograms. This study was designed to establish the pixel size necessary to identify accurately stenotic and ulcerative lesions of the carotid artery.
NASA Astrophysics Data System (ADS)
Bury, Yannick; Lucas, Matthieu; Bonnaud, Cyril; Joly, Laurent; ISAE Team; Airbus Team
2014-11-01
We study numerically and experimentally the vortices that develop past a model geometry of a wing equipped with pylon-mounted engine at low speed/moderate incidence flight conditions. For such configuration, the presence of the powerplant installation under the wing initiates a complex, unsteady vortical flow field at the nacelle/pylon/wing junctions. Its interaction with the upper wing boundary layer causes a drop of aircraft performances. In order to decipher the underlying physics, this study is initially conducted on a simplified geometry at a Reynolds number of 200000, based on the chord wing and on the freestream velocity. Two configurations of angle of attack and side-slip angle are investigated. This work relies on unsteady Reynolds Averaged Navier Stokes computations, oil flow visualizations and stereoscopic Particle Image Velocimetry measurements. The vortex dynamics thus produced is described in terms of vortex core position, intensity, size and turbulent intensity thanks to a vortex tracking approach. In addition, the analysis of the velocity flow fields obtained from PIV highlights the influence of the longitudinal vortex initiated at the pylon/wing junction on the separation process of the boundary layer near the upper wing leading-edge.
Optically driven oscillations of ellipsoidal particles. Part I: experimental observations.
Mihiretie, B M; Snabre, P; Loudet, J-C; Pouligny, B
2014-12-01
We report experimental observations of the mechanical effects of light on ellipsoidal micrometre-sized dielectric particles, in water as the continuous medium. The particles, made of polystyrene, have shapes varying between near disk-like (aspect ratio k = 0.2) to very elongated needle-like (k = 8). Rather than the very tightly focused beam geometry of optical tweezers, we use a moderately focused laser beam to manipulate particles individually by optical levitation. The geometry allows us varying the longitudinal position of the particle, and to capture images perpendicular to the beam axis. Experiments show that moderate-k particles are radially trapped with their long axis lying parallel to the beam. Conversely, elongated (k > 3) or flattened (k < 0.3) ellipsoids never come to rest, and permanently "dance" around the beam, through coupled translation-rotation motions. The oscillations are shown to occur in general, be the particle in bulk water or close to a solid boundary, and may be periodic or irregular. We provide evidence for two bifurcations between static and oscillating states, at k ≈ 0.33 and k ≈ 3 for oblate and prolate ellipsoids, respectively. Based on a recently developed 2-dimensional ray-optics simulation (Mihiretie et al., EPL 100, 48005 (2012)), we propose a simple model that allows understanding the physical origin of the oscillations.
Head Circumference as a Useful Surrogate for Intracranial Volume in Older Adults
Hshieh, Tammy T.; Fox, Meaghan L.; Kosar, Cyrus M.; Cavallari, Michele; Guttmann, Charles R.G.; Alsop, David; Marcantonio, Edward R.; Schmitt, Eva M.; Jones, Richard N.; Inouye, Sharon K.
2015-01-01
Background Intracranial volume (ICV) has been proposed as a measure of maximum lifetime brain size. Accurate ICV measures require neuroimaging which is not always feasible for epidemiologic investigations. We examined head circumference as a useful surrogate for intracranial volume in older adults. Methods 99 older adults underwent Magnetic Resonance Imaging (MRI). ICV was measured by Statistical Parametric Mapping 8 (SPM8) software or Functional MRI of the Brain Software Library (FSL) extraction with manual editing, typically considered the gold standard. Head circumferences were determined using standardized tape measurement. We examined estimated correlation coefficients between head circumference and the two MRI-based ICV measurements. Results Head circumference and ICV by SPM8 were moderately correlated (overall r=0.73, men r=0.67, women r=0.63). Head circumference and ICV by FSL were also moderately correlated (overall r=0.69, men r=0.63, women r=0.49). Conclusions Head circumference measurement was strongly correlated with MRI-derived ICV. Our study presents a simple method to approximate ICV among older patients, which may prove useful as a surrogate for cognitive reserve in large scale epidemiologic studies of cognitive outcomes. This study also suggests the stability of head circumference correlation with ICV throughout the lifespan. PMID:26631180
Computer measurement of particle sizes in electron microscope images
NASA Technical Reports Server (NTRS)
Hall, E. L.; Thompson, W. B.; Varsi, G.; Gauldin, R.
1976-01-01
Computer image processing techniques have been applied to particle counting and sizing in electron microscope images. Distributions of particle sizes were computed for several images and compared to manually computed distributions. The results of these experiments indicate that automatic particle counting within a reasonable error and computer processing time is feasible. The significance of the results is that the tedious task of manually counting a large number of particles can be eliminated while still providing the scientist with accurate results.
NASA Technical Reports Server (NTRS)
Kadambi, Jaikrishnan R. (Inventor); Wernet, Mark P. (Inventor); Mielke, Amy F. (Inventor)
2005-01-01
A method for determining a mass flux of an entrained phase in a planar two-phase flow records images of particles in the two-phase flow. Respective sizes of the particles (the entrained phase) are determined as a function of a separation between spots identified on the particle images. Respective velocities of the particles are determined. The mass flux of the entrained phase is determined as a function of the size and velocity of the particles.
Pilates for Low Back Pain: Complete Republication of a Cochrane Review.
Yamato, Tiê P; Maher, Christopher G; Saragiotto, Bruno T; Hancock, Mark J; Ostelo, Raymond W J G; Cabral, Cristina M N; Costa, Luciola C Menezes; Costa, Leonardo O P
2016-06-01
Systematic review. To determine the effects of the Pilates method for patients with nonspecific acute, subacute, or chronic low back pain. The Pilates method is one of the most common forms of intervention based on exercise used for treating patients with low back pain. However, its effectiveness is not well established. We conducted searches on CENTRAL, MEDLINE, EMBASE, CINAHL, PEDro, and SPORTDiscus up to March 2014. We included randomized controlled trials examining the effectiveness of Pilates in patients with acute, subacute, or chronic nonspecific low back pain. The outcomes evaluated were pain, disability, function, and global impression of recovery. Two independent reviewers screened for potentially eligible studies, assessed risk of bias, and extracted the data. We evaluated the overall quality of evidence using the GRADE approach and treatment effect sizes were described using mean differences and 95% confidence intervals. Searches retrieved 126 trials, of which 10 were included in the review (n = 510 participants). Seven studies were considered to have low risk of bias, and three were considered at high risk of bias. When compared to minimal intervention, Pilates reduces pain at short and intermediate term with low- to moderate-quality evidence and medium effect sizes. For disability, there is also a significant difference in favor to Pilates with low- to moderate-quality evidence and small effect size for short term and medium effect size for intermediate term compared with minimal intervention. It is unclear whether Pilates is better than other exercises for short-term pain, but there is low-quality evidence that Pilates reduces pain at intermediate term. For disability, there is moderate-quality evidence that there is no significant difference between Pilates and other exercises in either the short term or the intermediate term. There is low- to moderate-quality evidence that Pilates is more effective than minimal intervention with most of the effect sizes being considered medium. However, there is no conclusive evidence that Pilates is superior to other forms of exercises. 1.
SU-F-207-16: CT Protocols Optimization Using Model Observer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tseng, H; Fan, J; Kupinski, M
2015-06-15
Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settingsmore » are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.« less
Cai, You-zhi; Zhang, Chi; Lin, Xiang-jin
2015-12-01
The use of platelet-rich plasma (PRP) is an innovative clinical therapy, especially in arthroscopic rotator cuff repair. The purpose of this study was to compare the clinical improvement and tendon-to-bone healing with and without PRP therapy in arthroscopic rotator cuff repair. A systematic search was done in the major medical databases to evaluate the studies using PRP therapy (PRP+) or with no PRP (PRP-) for the treatment of patients with rotator cuff tears. We reviewed clinical scores such as the Constant score, the American Shoulder and Elbow Surgeons score, the University of California at Los Angeles (UCLA) Shoulder Rating Scale, the Simple Shoulder Test, and the failure-to-heal rate by magnetic resonance imaging between PRP+ and PRP- groups. Five studies included in this review were used for a meta-analysis based on data availability. There were no statistically significant differences between PRP+ and PRP- groups for overall outcome scores (P > .05). However, the PRP+ group exhibited better healing rates postoperatively than the PRP- group (P = .03) in small/moderate full-thickness tears. The use of PRP therapy in full-thickness rotator cuff repairs showed no statistically significant difference compared with no PRP therapy in clinical outcome scores, but the failure-to-heal rate was significantly decreased when PRP was used for treatment of small-to-moderately sized tears. PRP therapy may improve tendon-to-bone healing in patients with small or moderate rotator cuff tears. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
UAVSAR Acquires False-Color Image of Galeras Volcano, Colombia
2013-04-03
This false-color image of Colombia Galeras Volcano, was acquired by UAVSAR on March 13, 2013. A highly active volcano, Galeras features a breached caldera and an active cone that produces numerous small to moderate explosive eruptions.
Meta-Analysis and Inadequate Responders to Intervention: A Reply
ERIC Educational Resources Information Center
Swanson, H. Lee
2012-01-01
A meta-analysis by Tran, Sanchez, Arellano, and Swanson (2011) of the published RTI literature found that the magnitude of effect size (ES) between responders and low responders at posttest was significantly moderated by the pretest ES and the type of dependent measure administered, whereas no significant moderating effects were found in the mixed…
A Meta-Analysis of Attachment to Parents and Delinquency
ERIC Educational Resources Information Center
Hoeve, Machteld; Stams, Geert Jan J. M.; van der Put, Claudia E.; Dubas, Judith Semon; van der Laan, Peter H.; Gerris, Jan R. M.
2012-01-01
To investigate the link between attachment to parents and delinquency, and the potential moderating effects of age and sex, 74 published and unpublished manuscripts (N = 55,537 participants) were subjected to a multilevel meta-analysis. A mean small to moderate effect size was found (r = 0.18). Poor attachment to parents was significantly linked…
Saber, Deborah A
2014-01-01
Frontline registered nurses' job satisfaction is important because it is tied to retention, organizational commitment, workforce safety, patient safety, and cost savings. The purpose of this study was to comprehensively, quantitatively examine the largest, moderate, and smallest predictors of frontline registered nurse job satisfaction from 1980 to 2009. A non-a priori meta-analysis was used to analyze studies that met inclusion. Sixty-two studies and 27 job satisfaction predictors met inclusion for analysis. The largest effect sizes were found for task requirements (r = .61), empowerment (r = .55), and control (r = .52), and moderate effect sizes were found for 10 predictors. Fail-safe N indicates high reliability. Heterogeneity between studies was present in all of the 27 predictor analyses. The largest predictors of job satisfaction for the frontline registered nurse may be different than previously thought. Supporting past research, autonomy and stress were found to be moderate predictors of satisfaction. Heterogeneity indicates study differences or moderator influence in studies. Copyright © 2014 Elsevier Inc. All rights reserved.
Quantum watermarking scheme through Arnold scrambling and LSB steganography
NASA Astrophysics Data System (ADS)
Zhou, Ri-Gui; Hu, Wenwen; Fan, Ping
2017-09-01
Based on the NEQR of quantum images, a new quantum gray-scale image watermarking scheme is proposed through Arnold scrambling and least significant bit (LSB) steganography. The sizes of the carrier image and the watermark image are assumed to be 2n× 2n and n× n, respectively. Firstly, a classical n× n sized watermark image with 8-bit gray scale is expanded to a 2n× 2n sized image with 2-bit gray scale. Secondly, through the module of PA-MOD N, the expanded watermark image is scrambled to a meaningless image by the Arnold transform. Then, the expanded scrambled image is embedded into the carrier image by the steganography method of LSB. Finally, the time complexity analysis is given. The simulation experiment results show that our quantum circuit has lower time complexity, and the proposed watermarking scheme is superior to others.
Spine Instability Neoplastic Score: agreement across different medical and surgical specialties.
Arana, Estanislao; Kovacs, Francisco M; Royuela, Ana; Asenjo, Beatriz; Pérez-Ramírez, Úrsula; Zamora, Javier
2016-05-01
Spinal instability is an acknowledged complication of spinal metastases; in spite of recent suggested criteria, it is not clearly defined in the literature. This study aimed to assess intra and interobserver agreement when using the Spine Instability Neoplastic Score (SINS) by all physicians involved in its management. Independent multicenter reliability study for the recently created SINS, undertaken with a panel of medical oncologists, neurosurgeons, radiologists, orthopedic surgeons, and radiation oncologists, was carried out. Ninety patients with biopsy-proven spinal metastases and magnetic resonance imaging, reviewed at the multidisciplinary tumor board of our institution, were included. Intraclass correlation coefficient (ICC) was used for SINS score agreement. Fleiss kappa statistic was used to assess agreement on the location of the most affected vertebral level; agreement on the SINS category ("stable," "potentially stable," or "unstable"); and overall agreement with the classification established by tumor board. Clinical data and imaging were provided to 83 specialists in 44 hospitals across 14 Spanish regions. No assessment criteria were pre-established. Each clinician assessed the SINS score twice, with a minimum 6-week interval. Clinicians were blinded to assessments made by other specialists and to their own previous assessment. Subgroup analyses were performed by clinicians' specialty, experience (≤7, 8-13, ≥14 years), and hospital category (four levels according to size and complexity). This study was supported by Kovacs Foundation. Intra and interobserver agreement on the location of the most affected levels was "almost perfect" (κ>0.94). Intra-observer agreement on the SINS score was "excellent" (ICC=0.77), whereas interobserver agreement was "moderate" (ICC=0.55). Intra-observer agreement in SINS category was "substantial" (k=0.61), whereas interobserver agreement was "moderate" (k=0.42). Overall agreement with the tumor board classification was "substantial" (κ=0.61). Results were similar across specialties, years of experience, and hospital category. Agreement on the assessment of metastatic spine instability is moderate. The SINS can help improve communication among clinicians in oncology care. Copyright © 2015 Elsevier Inc. All rights reserved.
Knee X-ray image analysis method for automated detection of Osteoarthritis
Shamir, Lior; Ling, Shari M.; Scott, William W.; Bos, Angelo; Orlov, Nikita; Macura, Tomasz; Eckley, D. Mark; Ferrucci, Luigi; Goldberg, Ilya G.
2008-01-01
We describe a method for automated detection of radiographic Osteoarthritis (OA) in knee X-ray images. The detection is based on the Kellgren-Lawrence classification grades, which correspond to the different stages of OA severity. The classifier was built using manually classified X-rays, representing the first four KL grades (normal, doubtful, minimal and moderate). Image analysis is performed by first identifying a set of image content descriptors and image transforms that are informative for the detection of OA in the X-rays, and assigning weights to these image features using Fisher scores. Then, a simple weighted nearest neighbor rule is used in order to predict the KL grade to which a given test X-ray sample belongs. The dataset used in the experiment contained 350 X-ray images classified manually by their KL grades. Experimental results show that moderate OA (KL grade 3) and minimal OA (KL grade 2) can be differentiated from normal cases with accuracy of 91.5% and 80.4%, respectively. Doubtful OA (KL grade 1) was detected automatically with a much lower accuracy of 57%. The source code developed and used in this study is available for free download at www.openmicroscopy.org. PMID:19342330
Jyotshna; Shanker, Karuna; Khare, Puja; Tiwari, Nimisha; Mohanty, Shilpa; Bawankule, Dnyaneshwar U; Pal, Anirban
2016-01-01
Metals reduction into submicro/nano size through bhasma preparations for therapeutic use is well established in ancient traditional system of Indian medicines i.e. Ayurveda. Recently, nanotechnology has drawn the attention of researchers to develeope various size and shape nanoparicles / composite for number of applications.In this article, we report the enrichment of lactone enriched fraction (LEF) by liquid-liquid portioning of Vernonia cinerea metabolic extract and sysnthesis of mediated nano-gold composite (LEF-AuNPs) in single step process. The morphological characteristic based on transmission electron microscope (TEM) image analysis showed that LEF-AuNPs were predominantly nanopolygons and nanobots in shapes ranging from 50-200 nm in size. Abundance of phytochemicals in both LEF and LEF-AuNPs was dissimilar. In LEF, montanol- a diterpenoid, while in LEF-AuNPs, neophytadiene- a phytanes was the major compound. HPLC profile of relatively polar compounds also varied drastically. In-vitro biocompatibility, cytotoxicity [MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) based assay] and storage stabilitiy of LEF-AuNPs were evaluated. The moderate ability of LEF-AuNPs to restrict parasitaemia, extended mean survival time of mice infected with Plasmodium berghei and lack of any evident toxicity provides new opportunities for the safe delivery and applications of such nanocomposites in malaria therapy.
NASA Astrophysics Data System (ADS)
Zheng, Bin; Leader, J. K.; Coxson, Harvey O.; Scuirba, Frank C.; Fuhrman, Carl R.; Balkan, Arzu; Weissfeld, Joel L.; Maitz, Glenn S.; Gur, David
2006-03-01
The fraction of lung voxels below a pixel value "cut-off" has been correlated with pathologic estimates of emphysema. We performed a "standard" quantitative CT (QCT) lung analysis using a -950 HU cut-off to determine the volume fraction of emphysema (below the cut-off) and a "corrected" QCT analysis after removing small group (5 and 10 pixels) of connected pixels ("blobs") below the cut-off. CT examinations two dataset of 15 subjects each with a range of visible emphysema and pulmonary obstruction were acquired at "low-dose and conventional dose reconstructed using a high-spatial frequency kernel at 2.5 mm section thickness for the same subject. The "blob" size (i.e., connected-pixels) removed was inversely related to the computed fraction of emphysema. The slopes of emphysema fraction versus blob size were 0.013, 0.009, and 0.005 for subjects with both no emphysema and no pulmonary obstruction, moderate emphysema and pulmonary obstruction, and severe emphysema and severe pulmonary obstruction, respectively. The slopes of emphysema fraction versus blob size were 0.008 and 0.006 for low-dose and conventional CT examinations, respectively. The small blobs of pixels removed are most likely CT image artifacts and do not represent actual emphysema. The magnitude of the blob correction was appropriately associated with COPD severity. The blob correction appears to be applicable to QCT analysis in low-dose and conventional CT exams.
Left Atrial Enlargement and Stroke Recurrence: The Northern Manhattan Stroke Study
Yaghi, Shadi; Moon, Yeseon P.; Mora-McLaughlin, Consuelo; Willey, Joshua Z.; Cheung, Ken; Tullio, Marco R. Di; Homma, Shunichi; Kamel, Hooman; Sacco, Ralph L.; Elkind, Mitchell S. V.
2015-01-01
Background and purpose While left atrial enlargement (LAE) increases incident stroke risk, the association with recurrent stroke is less clear. Our aim was to determine the association of LAE with recurrent stroke most likely related to embolism (cryptogenic and cardioembolic), and all ischemic stroke recurrences. Methods We followed 655 first ischemic stroke patients in the Northern Manhattan Stroke Study for up to 5 years. LA size from 2-D echocardiography was categorized as normal (52.7%), mild LAE (31.6%), and moderate-severe LAE (15.7%). We used Cox proportional hazard models to calculate the hazard ratios and 95% confidence intervals (HR, 95%CI) for the association of LA size and LAE with recurrent cryptogenic/cardioembolic and total recurrent ischemic stroke. Results LA size was available in 529 (81%) patients. Mean age at enrollment was 69±13 years; 45.8% were male, 54.0% Hispanic, and 18.5% had atrial fibrillation. Over a median of 4 years there were 65 recurrent ischemic strokes (29 were cardioembolic or cryptogenic). In multivariable models adjusted for confounders including atrial fibrillation and heart failure, moderate-severe LAE compared to normal LA size was associated with greater risk of recurrent cardioembolic/cryptogenic stroke (adjusted HR 2.83, 95% CI 1.03-7.81), but not total ischemic stroke (adjusted HR 1.06, 95% CI, 0.48-2.30). Mild LAE was not associated with recurrent stroke. Conclusion Moderate to severe LAE was an independent marker of recurrent cardioembolic or cryptogenic stroke in a multiethnic cohort of ischemic stroke patients. Further research is needed to determine whether anticoagulant use may reduce risk of recurrence in ischemic stroke patients with moderate to severe LAE. PMID:25908460
Global CALIPSO Observations of Aerosol Changes Near Clouds
NASA Technical Reports Server (NTRS)
Varnai, Tamas; Marshak, Alexander
2011-01-01
Several recent studies have found that clouds are surrounded by a transition zone of rapidly changing aerosol optical properties and particle size. Characterizing this transition zone is important for better understanding aerosol-cloud interactions and aerosol radiative effects, and also for improving satellite retrievals of aerosol properties. This letter presents a statistical analysis of a monthlong global data set of Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) lidar observations over oceans. The results show that the transition zone is ubiquitous over all oceans and extends up to 15 km away from clouds. They also show that near-cloud enhancements in backscatter and particle size are strongest at low altitudes, slightly below the top of the nearest clouds. Also, the enhancements are similar near illuminated and shadowy cloud sides, which confirms that the asymmetry of Moderate Resolution Imaging Spectroradiometer reflectances found in an earlier study comes from 3-D radiative processes and not from differences in aerosol properties. Finally, the effects of CALIPSO aerosol detection and cloud identification uncertainties are discussed. The findings underline the importance of accounting for the transition zone to avoid potential biases in studies of satellite aerosol products, aerosol-cloud interactions, and aerosol direct radiative effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Chengshang; Fang, Zhigang Zak; Bowman, Robert C.
2015-10-01
In Part I, the cyclic stabilities of the kinetics of catalyzed MgH2 systems including MgH2–TiH2, MgH2–TiMn2, and MgH2–VTiCr were investigated, showing stable kinetics at 300 °C but deteriorations of the hydrogenation kinetics at temperatures below 150 °C. The present Part II describes the characterization of uncycled and cycled catalyzed MgH2 by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) analysis. XRD analysis shows the crystallite sizes of the Mg and MgH2 significantly increased after the cycling. The mean crystallite sizes of the catalysts (TiH2 and VTiCr) increased moderately after the cycling. SEMmore » and TEM imaging were used to compare the microstructures of uncycled (as-milled) and cycled materials, revealing a drastic change of the microstructure after 100 cycles. In particular, results from energy-dispersive spectroscopy (EDS) mapping show that a change of distribution of the catalyst particles in the Mg and MgH2 phase occurred during the cycling.« less
Marano, María Rosa; Carrillo, Néstor
1992-01-01
The size distribution of plastid transcripts during chromoplast differentiation in ripening tomato (Lycopersicon esculentum L.) fruits was determined using northern blot analysis. Hybridization of total cellular RNA from leaves and fruits with several tobacco chloroplast DNA probes showed distinct transcript patterns in chloroplasts and chromoplasts. We also compared transcriptional rates by probing immobilized DNA fragments of small size (representing about 85% of the plastid genome) with run-on transcripts from tomato plastids. The relative rates of transcription of the various DNA regions were very similar in chloro- and chromoplasts. Parallel determination of the steady-state levels of plastid RNA showed no strict correlation between synthesis rate and RNA accumulation. Differences in the relative abundance of transcripts between chloro- and chromoplasts were not very pronounced and were limited to a small number of genes. The results indicate that the conversion of chloroplasts to chromoplasts at the onset of tomato fruit ripening proceeds with no important variations in the relative transcription rates and with only moderate changes in the relative stability of plastid-encoded transcripts. Images Figure 1 Figure 4 PMID:16653091
Patient-specific finite element analysis of ascending aorta aneurysms
Martin, Caitlin; Elefteriades, John
2015-01-01
Catastrophic ascending aorta aneurysm (AsAA) dissection and rupture can be prevented by elective surgical repair, but identifying individuals at risk remains a challenge. Typically the decision to operate is based primarily on the overall aneurysm size, which may not be a reliable indicator of risk. In this study, AsAA inflation and rupture was simulated in 27 patient-specific finite element models constructed from clinical CT imaging data and tissue mechanical testing data from matching patients. These patients included n = 8 with concomitant bicuspid aortic valve (BAV), n = 10 with bovine aortic arch (BAA), and n = 10 with neither BAV nor BAA. AsAA rupture risk was found to increase with elevated systolic wall stress and tissue stiffness. The aortic size index was sufficient for identifying the patients with the lowest risk of rupture, but unsuitable for delineating between patients at moderate and high risk. There was no correlation between BAV or BAA and AsAA rupture risk; however, the AsAA morphology was different among these patients. These results support the use of mechanical parameters such as vessel wall stress and tissue stiffness for AsAA presurgical evaluation. PMID:25770248
Crown-root morphology of lower incisors in patients with class III malocclusion.
Wang, Bo; Shen, Guofang; Fang, Bing; Zhang, Li
2012-07-01
The purpose of this study was to investigate the crown-root morphology of lower incisors in patients with class III malocclusion using cone-beam computed tomography. Cone-beam computed tomography images were analyzed from 53 adult class I patients (group 1), 37 preadolescent class III patients (group 2), and 66 adult class III patients (group 3) comprising 3 divisions (divisions 1, 2, and 3 corresponded to mild, moderate, and severe class III malocclusions). The size and crown-root angulations of lower incisors in different groups and divisions were statistically appraised with group 1 used as the control group. No significant differences were found for the size of lower incisors among different groups and divisions (P > 0.05). Compared with group 1, the crown-root angulations of lower incisors in groups 2 and 3 were significantly larger (P < 0.01), and among 3 divisions, the lower incisors of division 3 rather than divisions 2 and 3 exhibited larger crown-root angulations (P < 0.01). Attention should be paid to the enlarged crown-root angulations of lower incisors in class III patients during orthodontic and orthognathic treatment, especially in severe ones.
Visually Lossless JPEG 2000 for Remote Image Browsing
Oh, Han; Bilgin, Ali; Marcellin, Michael
2017-01-01
Image sizes have increased exponentially in recent years. The resulting high-resolution images are often viewed via remote image browsing. Zooming and panning are desirable features in this context, which result in disparate spatial regions of an image being displayed at a variety of (spatial) resolutions. When an image is displayed at a reduced resolution, the quantization step sizes needed for visually lossless quality generally increase. This paper investigates the quantization step sizes needed for visually lossless display as a function of resolution, and proposes a method that effectively incorporates the resulting (multiple) quantization step sizes into a single JPEG2000 codestream. This codestream is JPEG2000 Part 1 compliant and allows for visually lossless decoding at all resolutions natively supported by the wavelet transform as well as arbitrary intermediate resolutions, using only a fraction of the full-resolution codestream. When images are browsed remotely using the JPEG2000 Interactive Protocol (JPIP), the required bandwidth is significantly reduced, as demonstrated by extensive experimental results. PMID:28748112
Paula, Jonas Jardim de; Miranda, Débora Marques; Nicolato, Rodrigo; Moraes, Edgar Nunes de; Bicalho, Maria Aparecida Camargos; Malloy-Diniz, Leandro Fernandes
2013-09-01
Depressive pseudodementia (DPD) is a clinical condition characterized by depressive symptoms followed by cognitive and functional impairment characteristics of dementia. Memory complaints are one of the most related cognitive symptoms in DPD. The present study aims to assess the verbal learning profile of elderly patients with DPD. Ninety-six older adults (34 DPD and 62 controls) were assessed by neuropsychological tests including the Rey auditory-verbal learning test (RAVLT). A multivariate general linear model was used to assess group differences and controlled for demographic factors. Moderate or large effects were found on all RAVLT components, except for short-term and recognition memory. DPD impairs verbal memory, with large effect size on free recall and moderate effect size on the learning. Short-term storage and recognition memory are useful in clinical contexts when the differential diagnosis is required.
Sauropod dinosaurs evolved moderately sized genomes unrelated to body size
Organ, Chris L.; Brusatte, Stephen L.; Stein, Koen
2009-01-01
Sauropodomorph dinosaurs include the largest land animals to have ever lived, some reaching up to 10 times the mass of an African elephant. Despite their status defining the upper range for body size in land animals, it remains unknown whether sauropodomorphs evolved larger-sized genomes than non-avian theropods, their sister taxon, or whether a relationship exists between genome size and body size in dinosaurs, two questions critical for understanding broad patterns of genome evolution in dinosaurs. Here we report inferences of genome size for 10 sauropodomorph taxa. The estimates are derived from a Bayesian phylogenetic generalized least squares approach that generates posterior distributions of regression models relating genome size to osteocyte lacunae volume in extant tetrapods. We estimate that the average genome size of sauropodomorphs was 2.02 pg (range of species means: 1.77–2.21 pg), a value in the upper range of extant birds (mean = 1.42 pg, range: 0.97–2.16 pg) and near the average for extant non-avian reptiles (mean = 2.24 pg, range: 1.05–5.44 pg). The results suggest that the variation in size and architecture of genomes in extinct dinosaurs was lower than the variation found in mammals. A substantial difference in genome size separates the two major clades within dinosaurs, Ornithischia (large genomes) and Saurischia (moderate to small genomes). We find no relationship between body size and estimated genome size in extinct dinosaurs, which suggests that neutral forces did not dominate the evolution of genome size in this group. PMID:19793755
Dai, Jessica C; Dunmire, Barbrina; Sternberg, Kevan M; Liu, Ziyue; Larson, Troy; Thiel, Jeff; Chang, Helena C; Harper, Jonathan D; Bailey, Michael R; Sorensen, Mathew D
2018-05-01
Posterior acoustic shadow width has been proposed as a more accurate measure of kidney stone size compared to direct measurement of stone width on ultrasound (US). Published data in humans to date have been based on a research using US system. Herein, we compared these two measurements in clinical US images. Thirty patient image sets where computed tomography (CT) and US images were captured less than 1 day apart were retrospectively reviewed. Five blinded reviewers independently assessed the largest stone in each image set for shadow presence and size. Shadow size was compared to US and CT stone sizes. Eighty percent of included stones demonstrated an acoustic shadow; 83% of stones without a shadow were ≤ 5 mm on CT. Average stone size was 6.5 ± 4.0 mm on CT, 10.3 ± 4.1 mm on US, and 7.5 ± 4.2 mm by shadow width. On average, US overestimated stone size by 3.8 ± 2.4 mm based on stone width (p < 0.001) and 1.0 ± 1.4 mm based on shadow width (p < 0.0098). Shadow measurements decreased misclassification of stones by 25% among three clinically relevant size categories (≤ 5, 5.1-10, > 10 mm), and by 50% for stones ≤ 5 mm. US overestimates stone size compared to CT. Retrospective measurement of the acoustic shadow from the same clinical US images is a more accurate reflection of true stone size than direct stone measurement. Most stones without a posterior shadow are ≤ 5 mm.
Sanyova, Jana; Cersoy, Sophie; Richardin, Pascale; Laprévote, Olivier; Walter, Philippe; Brunelle, Alain
2011-02-01
The painting materials of the Portrait of Nicolaes van Bambeeck (Royal Museums of Fine Arts of Belgium, Brussels, inv. 155) painted by Rembrandt van Rijn in 1641 has been studied using high resolution cluster-TOF-SIMS imaging. In the first step, a moderate spatial resolution (2 μm) was used to characterize the layer structure and the chemical composition of each layer on account of a high mass resolution. Then, in the second step, and despite a low mass resolution, the cluster primary ion beam was focused well below 1 μm in order to reveal smaller structures in the painting sample. The study confirmed the presence of starch in the second ground layer, which is quite surprising and, at least for Rembrandt paintings, has never been reported before. TOF-SIMS also indicated the presence of proteins, which, added to the size and shape of lake particles, suggests that it was manufactured from shearings (waste of textile manufacturing) of dyed wool, used as the source of the dyestuff. The analyses have also shown various lead carboxylates, being the products of the interaction between lead white and the oil of the binding medium. These findings considerably contribute to the understanding of Rembrandt's studio practice and thus demonstrate the importance and potential of cluster-TOF-SIMS imaging in the characterization on a submicrometer scale of artist painting materials.
A Semi-flexible 64-channel Receive-only Phased Array for Pediatric Body MRI at 3T
Zhang, Tao; Grafendorfer, Thomas; Cheng, Joseph Y.; Ning, Peigang; Rainey, Bob; Giancola, Mark; Ortman, Sarah; Robb, Fraser J.; Calderon, Paul D.; Hargreaves, Brian A.; Lustig, Michael; Scott, Greig C.; Pauly, John M.; Vasanawala, Shreyas S.
2015-01-01
Purpose To design, construct, and validate a semi-flexible 64-channel receive-only phased array for pediatric body MRI at 3T. Methods A 64-channel receive-only phased array was developed and constructed. The designed flexible coil can easily conform to different patient sizes with non-overlapping coil elements in the transverse plane. It can cover a field of view of up to 44 × 28 cm2 and removes the need for coil repositioning for body MRI patients with multiple clinical concerns. The 64-channel coil was compared with a 32-channel standard coil for signal-to-noise ratio (SNR) and parallel imaging performances on different phantoms. With IRB approval and informed consent/assent, the designed coil was validated on 21 consecutive pediatric patients. Results The pediatric coil provided higher SNR than the standard coil on different phantoms, with the averaged SNR gain at least 23% over a depth of 7 cm along the cross-section of phantoms. It also achieved better parallel imaging performance under moderate acceleration factors. Good image quality (average score 4.6 out of 5) was achieved using the developed pediatric coil in the clinical studies. Conclusion A 64-channel semi-flexible receive-only phased array has been developed and validated to facilitate high quality pediatric body MRI at 3T. PMID:26418283
Qian, Jing; Li, Xiaoyan; Song, Baihe; Wang, Bin; Wang, Menghan; Chang, Shumeng; Xiong, Yujiao
2018-01-01
We developed and tested a model to identify the role of leaders’ expressed humility on employees’ feedback-seeking processes. The data used in our study was from a sample of 248 employees and 57 of their immediate supervisors. The results revealed that: (1) leader’s expressed humility positively related to employees’ feedback seeking mediated by employees’ perceived image cost; and (2) power distance orientation moderated the relationship between leader’s expressed humility and employees’ perceived image costs, such that the relationship was stronger when the power distance orientation was lower rather than higher. The results offer new insight into potential managerial practices that aim at stimulating feedback seeking. We conclude with a discussion for future research. PMID:29720956
Wood, Tim J; Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W
2015-01-01
The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined "small pelvis" reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current-time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose.
The AzTEC/SMA Interferometric Imaging Survey of Submillimeter-selected High-redshift Galaxies
NASA Astrophysics Data System (ADS)
Younger, Joshua D.; Fazio, Giovanni G.; Huang, Jia-Sheng; Yun, Min S.; Wilson, Grant W.; Ashby, Matthew L. N.; Gurwell, Mark A.; Peck, Alison B.; Petitpas, Glen R.; Wilner, David J.; Hughes, David H.; Aretxaga, Itziar; Kim, Sungeun; Scott, Kimberly S.; Austermann, Jason; Perera, Thushara; Lowenthal, James D.
2009-10-01
We present results from a continuing interferometric survey of high-redshift submillimeter galaxies (SMGs) with the Submillimeter Array, including high-resolution (beam size ~2 arcsec) imaging of eight additional AzTEC 1.1 mm selected sources in the COSMOS field, for which we obtain six reliable (peak signal-to-noise ratio (S/N) >5 or peak S/N >4 with multiwavelength counterparts within the beam) and two moderate significance (peak S/N >4) detections. When combined with previous detections, this yields an unbiased sample of millimeter-selected SMGs with complete interferometric follow up. With this sample in hand, we (1) empirically confirm the radio-submillimeter association, (2) examine the submillimeter morphology—including the nature of SMGs with multiple radio counterparts and constraints on the physical scale of the far infrared—of the sample, and (3) find additional evidence for a population of extremely luminous, radio-dim SMGs that peaks at higher redshift than previous, radio-selected samples. In particular, the presence of such a population of high-redshift sources has important consequences for models of galaxy formation—which struggle to account for such objects even under liberal assumptions—and dust production models given the limited time since the big bang.
CERES cloud property retrievals from imagers on TRMM, Terra, and Aqua
NASA Astrophysics Data System (ADS)
Minnis, Patrick; Young, David F.; Sun-Mack, Sunny; Heck, Patrick W.; Doelling, David R.; Trepte, Qing Z.
2004-02-01
The micro- and macrophysical properties of clouds play a crucial role in Earth"s radiation budget. The NASA Clouds and Earth"s Radiant Energy System (CERES) is providing simultaneous measurements of the radiation and cloud fields on a global basis to improve the understanding and modeling of the interaction between clouds and radiation at the top of the atmosphere, at the surface, and within the atmosphere. Cloud properties derived for CERES from the Moderate Resolution Imaging Spectroradiometer (MODIS) on the Terra and Aqua satellites are compared to ensure consistency between the products to ensure the reliability of the retrievals from multiple platforms at different times of day. Comparisons of cloud fraction, height, optical depth, phase, effective particle size, and ice and liquid water paths from the two satellites show excellent consistency. Initial calibration comparisons are also very favorable. Differences between the Aqua and Terra results are generally due to diurnally dependent changes in the clouds. Additional algorithm refinement is needed over the polar regions for Aqua and at night over those same areas for Terra. The results should be extremely valuable for model validation and improvement and for improving our understanding of the relationship between clouds and the radiation budget.
Images of Bottomside Irregularities Observed at Topside Altitudes
NASA Technical Reports Server (NTRS)
Burke, William J.; Gentile, Louise C.; Shomo, Shannon R.; Roddy, Patrick A.; Pfaff, Robert F.
2012-01-01
We analyzed plasma and field measurements acquired by the Communication/ Navigation Outage Forecasting System (C/NOFS) satellite during an eight-hour period on 13-14 January 2010 when strong to moderate 250 MHz scintillation activity was observed at nearby Scintillation Network Decision Aid (SCINDA) ground stations. C/NOFS consistently detected relatively small-scale density and electric field irregularities embedded within large-scale (approx 100 km) structures at topside altitudes. Significant spectral power measured at the Fresnel (approx 1 km) scale size suggests that C/NOFS was magnetically conjugate to bottomside irregularities similar to those directly responsible for the observed scintillations. Simultaneous ion drift and plasma density measurements indicate three distinct types of large-scale irregularities: (1) upward moving depletions, (2) downward moving depletions, and (3) upward moving density enhancements. The first type has the characteristics of equatorial plasma bubbles; the second and third do not. The data suggest that both downward moving depletions and upward moving density enhancements and the embedded small-scale irregularities may be regarded as Alfvenic images of bottomside irregularities. This interpretation is consistent with predictions of previously reported theoretical modeling and with satellite observations of upward-directed Poynting flux in the low-latitude ionosphere.
Quick probabilistic binary image matching: changing the rules of the game
NASA Astrophysics Data System (ADS)
Mustafa, Adnan A. Y.
2016-09-01
A Probabilistic Matching Model for Binary Images (PMMBI) is presented that predicts the probability of matching binary images with any level of similarity. The model relates the number of mappings, the amount of similarity between the images and the detection confidence. We show the advantage of using a probabilistic approach to matching in similarity space as opposed to a linear search in size space. With PMMBI a complete model is available to predict the quick detection of dissimilar binary images. Furthermore, the similarity between the images can be measured to a good degree if the images are highly similar. PMMBI shows that only a few pixels need to be compared to detect dissimilarity between images, as low as two pixels in some cases. PMMBI is image size invariant; images of any size can be matched at the same quick speed. Near-duplicate images can also be detected without much difficulty. We present tests on real images that show the prediction accuracy of the model.
Enhanced pulsed magneto-motive ultrasound imaging using superparamagnetic nanoclusters
Mehrmohammadi, M; Yoon, KY; Qu, M; Johnston, KP; Emelianov, SY
2011-01-01
Recently, pulsed magneto-motive ultrasound (pMMUS) imaging augmented with ultra-small magnetic nanoparticles has been introduced as a tool capable of imaging events at molecular and cellular levels. The sensitivity of a pMMUS system depends on several parameters, including the size, geometry and magnetic properties of the nanoparticles. Under the same magnetic field, larger magnetic nanostructures experience a stronger magnetic force and produce larger displacement, thus improving the sensitivity and signal-to-noise ratio (SNR) of pMMUS imaging. Unfortunately, large magnetic iron-oxide nanoparticles are typically ferromagnetic and thus are very difficult to stabilize against colloidal aggregation. In the current study we demonstrate improvement of pMMUS image quality by using large size superparamagnetic nanoclusters characterized by strong magnetization per particle. Water-soluble magnetic nanoclusters of two sizes (15 and 55 nm average size) were synthesized from 3 nm iron precursors in the presence of citrate capping ligand. The size distribution of synthesized nanoclusters and individual nanoparticles was characterized using dynamic light scattering (DLS) analysis and transmission electron microscopy (TEM). Tissue mimicking phantoms containing single nanoparticles and two sizes of nanoclusters were imaged using a custom-built pMMUS imaging system. While the magnetic properties of citrate-coated nanoclusters are identical to those of superparamagnetic nanoparticles, the magneto-motive signal detected from nanoclusters is larger, i.e. the same magnetic field produced larger magnetically induced displacement. Therefore, our study demonstrates that clusters of superparamagnetic nanoparticles result in pMMUS images with higher contrast and SNR. PMID:21157009
A universal approximation to grain size from images of non-cohesive sediment
Buscombe, D.; Rubin, D.M.; Warrick, J.A.
2010-01-01
The two-dimensional spectral decomposition of an image of sediment provides a direct statistical estimate, grid-by-number style, of the mean of all intermediate axes of all single particles within the image. We develop and test this new method which, unlike existing techniques, requires neither image processing algorithms for detection and measurement of individual grains, nor calibration. The only information required of the operator is the spatial resolution of the image. The method is tested with images of bed sediment from nine different sedimentary environments (five beaches, three rivers, and one continental shelf), across the range 0.1 mm to 150 mm, taken in air and underwater. Each population was photographed using a different camera and lighting conditions. We term it a “universal approximation” because it has produced accurate estimates for all populations we have tested it with, without calibration. We use three approaches (theory, computational experiments, and physical experiments) to both understand and explore the sensitivities and limits of this new method. Based on 443 samples, the root-mean-squared (RMS) error between size estimates from the new method and known mean grain size (obtained from point counts on the image) was found to be ±≈16%, with a 95% probability of estimates within ±31% of the true mean grain size (measured in a linear scale). The RMS error reduces to ≈11%, with a 95% probability of estimates within ±20% of the true mean grain size if point counts from a few images are used to correct bias for a specific population of sediment images. It thus appears it is transferable between sedimentary populations with different grain size, but factors such as particle shape and packing may introduce bias which may need to be calibrated for. For the first time, an attempt has been made to mathematically relate the spatial distribution of pixel intensity within the image of sediment to the grain size.
A universal approximation of grain size from images of noncohesive sediment
NASA Astrophysics Data System (ADS)
Buscombe, D.; Rubin, D. M.; Warrick, J. A.
2010-06-01
The two-dimensional spectral decomposition of an image of sediment provides a direct statistical estimate, grid-by-number style, of the mean of all intermediate axes of all single particles within the image. We develop and test this new method which, unlike existing techniques, requires neither image processing algorithms for detection and measurement of individual grains, nor calibration. The only information required of the operator is the spatial resolution of the image. The method is tested with images of bed sediment from nine different sedimentary environments (five beaches, three rivers, and one continental shelf), across the range 0.1 mm to 150 mm, taken in air and underwater. Each population was photographed using a different camera and lighting conditions. We term it a "universal approximation" because it has produced accurate estimates for all populations we have tested it with, without calibration. We use three approaches (theory, computational experiments, and physical experiments) to both understand and explore the sensitivities and limits of this new method. Based on 443 samples, the root-mean-squared (RMS) error between size estimates from the new method and known mean grain size (obtained from point counts on the image) was found to be ±≈16%, with a 95% probability of estimates within ±31% of the true mean grain size (measured in a linear scale). The RMS error reduces to ≈11%, with a 95% probability of estimates within ±20% of the true mean grain size if point counts from a few images are used to correct bias for a specific population of sediment images. It thus appears it is transferable between sedimentary populations with different grain size, but factors such as particle shape and packing may introduce bias which may need to be calibrated for. For the first time, an attempt has been made to mathematically relate the spatial distribution of pixel intensity within the image of sediment to the grain size.
Everall, Neil J; Priestnall, Ian M; Clarke, Fiona; Jayes, Linda; Poulter, Graham; Coombs, David; George, Michael W
2009-03-01
This paper describes preliminary investigations into the spatial resolution of macro attenuated total reflection (ATR) Fourier transform infrared (FT-IR) imaging and the distortions that arise when imaging intact, convex domains, using spheres as an extreme example. The competing effects of shallow evanescent wave penetration and blurring due to finite spatial resolution meant that spheres within the range 20-140 microm all appeared to be approximately the same size ( approximately 30-35 microm) when imaged with a numerical aperture (NA) of approximately 0.2. A very simple model was developed that predicted this extreme insensitivity to particle size. On the basis of these studies, it is anticipated that ATR imaging at this NA will be insensitive to the size of intact highly convex objects. A higher numerical aperture device should give a better estimate of the size of small spheres, owing to superior spatial resolution, but large spheres should still appear undersized due to the shallow sampling depth. An estimate of the point spread function (PSF) was required in order to develop and apply the model. The PSF was measured by imaging a sharp interface; assuming an Airy profile, the PSF width (distance from central maximum to first minimum) was estimated to be approximately 20 and 30 microm for IR bands at 1600 and 1000 cm(-1), respectively. This work has two significant limitations. First, underestimation of domain size only arises when imaging intact convex objects; if surfaces are prepared that randomly and representatively section through domains, the images can be analyzed to calculate parameters such as domain size, area, and volume. Second, the model ignores reflection and refraction and assumes weak absorption; hence, the predicted intensity profiles are not expected to be accurate; they merely give a rough estimate of the apparent sphere size. Much further work is required to place the field of quantitative ATR-FT-IR imaging on a sound basis.
Imburgio, Michael J; Orr, Joseph M
2018-05-01
A meta-analysis of studies using single-session transcranial direct current stimulation (tDCS) to target the dorsolateral prefrontal cortex (DLPFC) was undertaken to examine the effect of stimulation on executive function (EF) in healthy samples. 27 studies were included in analyses, yielding 71 effect sizes. The most relevant measure for each task was determined a priori and used to calculate Hedge's g. Methodological characteristics of each study were examined individually as potential moderators of effect size. Stimulation effects on three domains of EF (inhibition of prepotent responses, mental set shifting, and information updating and monitoring) were analyzed separately. In line with previous work, the current study found no significant effect of anodal unilateral tDCS, cathodal unilateral tDCS, or bilateral tDCS on EF. Further moderator and subgroup analyses were only carried out for anodal unilateral montages due to the small number of studies using other montages. Subgroup analyses revealed a significant effect of anodal unilateral tDCS on updating tasks, but not on inhibition or set-shifting tasks. Cathode location significantly moderated the effect of anodal unilateral tDCS. Extracranial cathodes yielded a significant effect on EF while cranial cathodes yielded no effect. Anode size also significantly moderated effect of anodal unilateral tDCS, with smaller anodes being more effective than larger anodes. In summary, anodal DLPFC stimulation is more effective at improving updating ability than inhibition and set-shifting ability, but anodal stimulation can significantly improve general executive function when extracranial cathodes or small anodes are used. Future meta-analyses may examine how stimulation's effects on specific behavioral tasks, rather than broader domains, might be affected by methodological moderators. Copyright © 2018 Elsevier Ltd. All rights reserved.
de Freitas Silva, Leonardo; de Carvalho Reis, Erik Neiva Ribeiro; Barbara, Tânia Aparecida; Bonardi, João Paulo; Garcia, Idelmo Rangel; de Carvalho, Paulo Sérgio Perri; Ponzoni, Daniela
2017-07-01
Evaluating the osteoconductive property of tricalcium phosphate beta (β-TCP) in comparison to that of inorganic bovine bone for repair in a critical-size defect in the rat calvarium. Critical-size defects of 7mm were made with a trephine in the calvaria of 48 Wistar rats. The animals were divided into four groups, and the defects in each group were filled with tricalcium phosphate beta (β-TCP), inorganic bovine bone (Bio-Oss), autogenous bone, or left empty. The animals were euthanized at two different time points (30 and 60days post-operation). All defects were recovered with a absorbable membrane of bovine cortical bone. Histological, histometric, and immunohistochemical (osteocalcin) assessments were carried out at 30 and 60days post-operation. At 30days post-operation, all groups showed areas of bone formation, predominantly when autogenous grafts were used. However, there were no statistically significant differences between the treatment groups (p>0.05). After 60days, there were similarities in the bone formation patterns between the β-TCP (26.32±) and Bio-Oss (17.35±) groups (p=0.549). In terms of the immunohistochemical assessment of osteocalcin, the clot group showed light to moderate staining at 30 and 60days. The autogenous group showed moderate staining at 30days and moderate to intense staining after 60days. The Bio-Oss group showed light to moderate staining after 30days and intense staining at 60days. The β-TCP group showed moderate staining at 30 and 60days post-operation. β-TCP is a good osteoconductive material with similar effects to those of inorganic bovine bone graft and is suitable for utilization in the repair of bone defects. Copyright © 2017 Elsevier GmbH. All rights reserved.
2017-12-08
Like a ship carving its way through the sea, the South Georgia and South Sandwich Islands parted the clouds. The Moderate Resolution Imaging Spectroradiometer (MODIS) on NASA’s Terra satellite acquired this natural-color image on February 2, 2017. The ripples in the clouds are known as gravity waves. NASA image by Jeff Schmaltz, LANCE/EOSDIS Rapid Response #nasagoddard
Can the Media Affect Us? Social Comparison, Self-Discrepancy, and the Thin Ideal
ERIC Educational Resources Information Center
Bessenoff, Gayle R.
2006-01-01
The current study explored body image self-discrepancy as moderator and social comparison as mediator in the effects on women from thin-ideal images in the media. Female undergraduates (N = 112) with high and low body image self-discrepancy were exposed to advertisements either with thin women (thin ideal) or without thin women…
ERIC Educational Resources Information Center
Critchfield, Thomas S.; Reed, Derek D.
2016-01-01
Participants first became familiar with an image showing moderate symptoms of the skin cancer melanoma. In a generalization test, they indicated whether images showing more and less pronounced symptoms were "like the original." Some groups (cancer context) were told that the images depicted melanoma and that the disease is deadly unless…
Cyclone Hudah As Seen By MODIS
NASA Technical Reports Server (NTRS)
2002-01-01
Tropical Cyclone Hudah was one of most powerful storms ever seen in the Indian Ocean. This image from the Moderate-resolution Imaging Spectroradiometer (MODIS) aboard Terra was taken on March 29, 2000. The structure of the eye of the storm is brought out by MODIS' 250-meter resolution. Image by Liam Gumley, Space Science and Engineering Center, University of Wisconsin-Madison
MRI of placenta percreta: differentiation from other entities of placental adhesive disorder.
Thiravit, Shanigarn; Lapatikarn, Sukanya; Muangsomboon, Kobkun; Suvannarerg, Voraparee; Thiravit, Phakphoom; Korpraphong, Pornpim
2017-01-01
To retrospectively review the MRI findings of placenta percreta and identify those helpful for differentiation from non-placenta percreta. The MRI images of 21 patients with a preliminary diagnosis of placental adhesive disorder scanned between 2005 and 2014 were evaluated. Radiologists blinded to the final diagnosis evaluated six previously described MRI findings of placenta adhesive disorder. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predictive value (PPV) of MRI for the diagnosis of placenta percreta were also calculated. The study included 12 cases of placenta percreta and 9 cases of non-placenta percreta. Invasion of placental tissue outside the uterus was found only in placenta percreta (p = 0.045; sensitivity 41.7 %; specificity 100 %). All placenta percreta cases also had a moderate to marked degree of heterogeneous placental signal intensity (p = 0.063; sensitivity 100 %; specificity 33.3 %). The size of the dark bands on T2-weighted imaging, and the presence of disorganized intra-placental vessels, showed no statistically significant difference between placenta percreta and non-placenta percreta. The sensitivity, specificity, NPV, PPV, and accuracy of MRI for detection of placenta percreta were 91.7, 44, 80, 68, and 71.4 %, respectively. MRI is recommended for the evaluation of placenta percreta, with the most specific signs including the invasion of placental tissue outside the uterus on B-FFE sequences, and consideration of the degree of placental signal heterogeneity. The size of the T2 dark band alone, or bizarre disorganized intra-placental vessels, did not correlate with the severity of invasion.
Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse
2014-12-01
The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.
Atmospheric Retrieval Analysis of the Directly Imaged Exoplanet HR 8799b
NASA Astrophysics Data System (ADS)
Lee, Jae-Min; Heng, Kevin; Irwin, Patrick G. J.
2013-12-01
Directly imaged exoplanets are unexplored laboratories for the application of the spectral and temperature retrieval method, where the chemistry and composition of their atmospheres are inferred from inverse modeling of the available data. As a pilot study, we focus on the extrasolar gas giant HR 8799b, for which more than 50 data points are available. We upgrade our non-linear optimal estimation retrieval method to include a phenomenological model of clouds that requires the cloud optical depth and monodisperse particle size to be specified. Previous studies have focused on forward models with assumed values of the exoplanetary properties; there is no consensus on the best-fit values of the radius, mass, surface gravity, and effective temperature of HR 8799b. We show that cloud-free models produce reasonable fits to the data if the atmosphere is of super-solar metallicity and non-solar elemental abundances. Intermediate cloudy models with moderate values of the cloud optical depth and micron-sized particles provide an equally reasonable fit to the data and require a lower mean molecular weight. We report our best-fit values for the radius, mass, surface gravity, and effective temperature of HR 8799b. The mean molecular weight is about 3.8, while the carbon-to-oxygen ratio is about unity due to the prevalence of carbon monoxide. Our study emphasizes the need for robust claims about the nature of an exoplanetary atmosphere to be based on analyses involving both photometry and spectroscopy and inferred from beyond a few photometric data points, such as are typically reported for hot Jupiters.
Comparing synthetic imagery with real imagery for visible signature analysis: human observer results
NASA Astrophysics Data System (ADS)
Culpepper, Joanne B.; Richards, Noel; Madden, Christopher S.; Winter, Neal; Wheaton, Vivienne C.
2017-10-01
Synthetic imagery could potentially enhance visible signature analysis by providing a wider range of target images in differing environmental conditions than would be feasible to collect in field trials. Achieving this requires a method for generating synthetic imagery that is both verified to be realistic and produces the same visible signature analysis results as real images. Is target detectability as measured by image metrics the same for real images and synthetic images of the same scene? Is target detectability as measured by human observer trials the same for real images and synthetic images of the same scene, and how realistic do the synthetic images need to be? In this paper we present the results of a small scale exploratory study on the second question: a photosimulation experiment conducted using digital photographs and synthetic images generated of the same scene. Two sets of synthetic images were created: a high fidelity set created using an image generation tool, E-on Vue, and a low fidelity set created using a gaming engine, Unity 3D. The target detection results obtained using digital photographs were compared with those obtained using the two sets of synthetic images. There was a moderate correlation between the high fidelity synthetic image set and the real images in both the probability of correct detection (Pd: PCC = 0.58, SCC = 0.57) and mean search time (MST: PCC = 0.63, SCC = 0.61). There was no correlation between the low fidelity synthetic image set and the real images for the Pd, but a moderate correlation for MST (PCC = 0.67, SCC = 0.55).
77 FR 59692 - 2014 Diversity Immigrant Visa Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
... the E-DV system. The entry will not be accepted and must be resubmitted. Group or family photographs... must be in the Joint Photographic Experts Group (JPEG) format. Image File Size: The maximum file size...). Image File Format: The image must be in the Joint Photographic Experts Group (JPEG) format. Image File...
NASA Technical Reports Server (NTRS)
Grycewicz, Thomas J.; Tan, Bin; Isaacson, Peter J.; De Luccia, Frank J.; Dellomo, John
2016-01-01
In developing software for independent verification and validation (IVV) of the Image Navigation and Registration (INR) capability for the Geostationary Operational Environmental Satellite R Series (GOES-R) Advanced Baseline Imager (ABI), we have encountered an image registration artifact which limits the accuracy of image offset estimation at the subpixel scale using image correlation. Where the two images to be registered have the same pixel size, subpixel image registration preferentially selects registration values where the image pixel boundaries are close to lined up. Because of the shape of a curve plotting input displacement to estimated offset, we call this a stair-step artifact. When one image is at a higher resolution than the other, the stair-step artifact is minimized by correlating at the higher resolution. For validating ABI image navigation, GOES-R images are correlated with Landsat-based ground truth maps. To create the ground truth map, the Landsat image is first transformed to the perspective seen from the GOES-R satellite, and then is scaled to an appropriate pixel size. Minimizing processing time motivates choosing the map pixels to be the same size as the GOES-R pixels. At this pixel size image processing of the shift estimate is efficient, but the stair-step artifact is present. If the map pixel is very small, stair-step is not a problem, but image correlation is computation-intensive. This paper describes simulation-based selection of the scale for truth maps for registering GOES-R ABI images.
ERIC Educational Resources Information Center
Turgut, Sedat; Temur, Özlem Dogan
2017-01-01
In this research, the effects of using game in mathematics teaching process on academic achievement in Turkey were examined by metaanalysis method. For this purpose, the average effect size value and the average effect size values of the moderator variables (education level, the field of education, game type, implementation period and sample size)…
Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca
2015-01-01
Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p < 0.001). Grayscale confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.
Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.
Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm
2006-01-01
To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.
Stem cells are dispensable for lung homeostasis but restore airways after injury.
Giangreco, Adam; Arwert, Esther N; Rosewell, Ian R; Snyder, Joshua; Watt, Fiona M; Stripp, Barry R
2009-06-09
Local tissue stem cells have been described in airways of the lung but their contribution to normal epithelial maintenance is currently unknown. We therefore developed aggregation chimera mice and a whole-lung imaging method to determine the relative contributions of progenitor (Clara) and bronchiolar stem cells to epithelial maintenance and repair. In normal and moderately injured airways chimeric patches were small in size and not associated with previously described stem cell niches. This finding suggested that single, randomly distributed progenitor cells maintain normal epithelial homeostasis. In contrast we found that repair following severe lung injury resulted in the generation of rare, large clonal cell patches that were associated with stem cell niches. This study provides evidence that epithelial stem cells are dispensable for normal airway homeostasis. We also demonstrate that stem cell activation and robust clonal cellular expansion occur only during repair from severe lung injury.
Validation of MODIS Aerosol Retrieval Over Ocean
NASA Technical Reports Server (NTRS)
Remer, Lorraine A.; Tanre, Didier; Kaufman, Yoram J.; Ichoku, Charles; Mattoo, Shana; Levy, Robert; Chu, D. Allen; Holben, Brent N.; Dubovik, Oleg; Ahmad, Ziauddin;
2001-01-01
The MODerate resolution Imaging Spectroradiometer (MODIS) algorithm for determining aerosol characteristics over ocean is performing with remarkable accuracy. A two-month data set of MODIS retrievals co-located with observations from the AErosol RObotic NETwork (AERONET) ground-based sunphotometer network provides the necessary validation. Spectral radiation measured by MODIS (in the range 550 - 2100 nm) is used to retrieve the aerosol optical thickness, effective particle radius and ratio between the submicron and micron size particles. MODIS-retrieved aerosol optical thickness at 660 nm and 870 nm fall within the expected uncertainty, with the ensemble average at 660 nm differing by only 2% from the AERONET observations and having virtually no offset. MODIS retrievals of aerosol effective radius agree with AERONET retrievals to within +/- 0.10 micrometers, while MODIS-derived ratios between large and small mode aerosol show definite correlation with ratios derived from AERONET data.
The nuclear window to the extragalactic universe
NASA Astrophysics Data System (ADS)
Erdmann, M.; Müller, G.; Urban, M.; Wirtz, M.
2016-12-01
We investigate two recent parameterizations of the galactic magnetic field with respect to their impact on cosmic nuclei traversing the field. We present a comprehensive study of the size of angular deflections, dispersion in the arrival probability distributions, multiplicity in the images of arrival on Earth, variance in field transparency, and influence of the turbulent field components. To remain restricted to ballistic deflections, a cosmic nucleus with energy E and charge Z should have a rigidity above E / Z = 6 EV. In view of the differences resulting from the two field parameterizations as a measure of current knowledge in the galactic field, this rigidity threshold may have to be increased. For a point source search with E/Z ≥ 60 EV, field uncertainties increase the required signal events for discovery moderately for sources in the northern and southern regions, but substantially for sources near the galactic disk.
Stabilized Alumina/Ethanol Colloidal Dispersion for Seeding High Temperature Air Flows
NASA Technical Reports Server (NTRS)
Wernet, Judith H.; Wernet, Mark P.
1994-01-01
Seeding air flows with particles to enable measurements of gas velocities via laser anemometry and/or particle image velocimetry techniques can be quite exasperating. The seeding requirements are compounded when high temperature environments are encountered and special care must be used in selecting a refractory seed material. The pH stabilization techniques commonly employed in ceramic processing are used to obtain stable dispersions for generating aerosols of refractory seed material. By adding submicron alumina particles to a preadjusted pH solution of ethanol, a stable dispersion is obtained which when atomized produces a high quality aerosol. Commercial grade alumina powder is used with a moderate size distribution. The technique is not limited to alumina/ethanol and is also demonstrated with an alumina/H2O system. Other ceramic powders in various polar solvents could also be used once the point of zero charge (pH(sub pzc)) of the powder in the solvent has been determined.
Synergetic use of Aerosol Robotic Network (AERONET) and Moderate Image Spectrometer (MODIS)
NASA Technical Reports Server (NTRS)
Kaufman, Y.
2004-01-01
I shall describe several distinct modes in which AERONET data are used in conjunction with MODIS data to evaluate the global aerosol system and its impact on climate. These includes: 1) Evaluation of the aerosol diurnal cycle not available from MODIS, and the relationship between the aerosol properties derived from MODIS and the daily average of these properties; 2) Climatology of the aerosol size distribution and single scattering albedo. The climatology is used to formulate the assumptions used in the MODIS look up tables used in the inversion of MODIS data; 3) Measurement of the aerosol effect on irradiation of the surface, this is used in conjunction with the MODIS evaluation of the aerosol effect at the TOA; and 4) Assessment of the aerosol baseline on top off which the satellite data are used to find the amount of dust or anthropogenic aerosol.
Gender Difference in the Prevalence of Eating Disorder Symptoms
Striegel-Moore, Ruth H.; Rosselli, Francine; Perrin, Nancy; DeBar, Lynn; Wilson, G. Terence; May, Alexis; Kraemer, Helena C.
2009-01-01
Objective This study examined gender differences in prevalence of eating disorder symptoms including body image concerns (body checking or avoidance), binge eating, and inappropriate compensatory behaviors. Method A random sample of members (ages 18 to 35) of a health maintenance organization was recruited to complete a survey by mail or on-line. Items were drawn from the Patient Health Questionnaire and the Body Shape Questionnaire. Results Among the 3,714 women and 1,808 men who responded, men were more likely to report overeating whereas women were more likely to endorse loss of control while eating. Although statistically significant gender differences were observe, with women significantly more likely than men to report body checking and avoidance, binge eating, fasting, and vomiting, effect sizes (“Number Needed to Treat”) were small to moderate. Conclusions Few studies of eating disorders include men, yet our findings suggest that a substantial minority of men also report eating disorder symptoms. PMID:19107833
Analysis of x-ray tomography data of an extruded low density styrenic foam: an image analysis study
NASA Astrophysics Data System (ADS)
Lin, Jui-Ching; Heeschen, William
2016-10-01
Extruded styrenic foams are low density foams that are widely used for thermal insulation. It is difficult to precisely characterize the structure of the cells in low density foams by traditional cross-section viewing due to the frailty of the walls of the cells. X-ray computed tomography (CT) is a non-destructive, three dimensional structure characterization technique that has great potential for structure characterization of styrenic foams. Unfortunately the intrinsic artifacts of the data and the artifacts generated during image reconstruction are often comparable in size and shape to the thin walls of the foam, making robust and reliable analysis of cell sizes challenging. We explored three different image processing methods to clean up artifacts in the reconstructed images, thus allowing quantitative three dimensional determination of cell size in a low density styrenic foam. Three image processing approaches - an intensity based approach, an intensity variance based approach, and a machine learning based approach - are explored in this study, and the machine learning image feature classification method was shown to be the best. Individual cells are segmented within the images after the images were cleaned up using the three different methods and the cell sizes are measured and compared in the study. Although the collected data with the image analysis methods together did not yield enough measurements for a good statistic of the measurement of cell sizes, the problem can be resolved by measuring multiple samples or increasing imaging field of view.
NASA Astrophysics Data System (ADS)
Yamamoto, Seiichi; Kawaguchi, Wataru
2018-06-01
For precise distribution measurements of alpha particles, a high-resolution alpha particle imaging detector is required. Although combining a thin scintillator with a silicon photomultiplier (Si-PM) array is a promising method for achieving high resolution, the spatial resolution is limited. Reducing the size of the Si-PM array is a possible approach to improving the spatial resolution of the alpha particle imaging detector. Consequently, we employed a 1 mm channel size Si-PM array combined with a thin ZnS(Ag) sheet to form an alpha particle imaging detector and evaluated the performance. For the developed alpha particle imaging detector, an Si-PM array with 1 mm x 1 mm channel size arranged 8 x 8 was optically coupled to a ZnS(Ag) sheet with a 1-mm-thick light guide between them. The size of the alpha particle imaging detector was 9.5 mm x 9.5 mm. The spatial resolution of the developed alpha particle imaging detector was 0.14 mm FWHM, and the energy resolution was 74% FWHM for 5.5 MeV alpha particles. The uniformity of the imaging detector at the central part of the field of view (FOV) was ±4.7%. The background count rate was 0.06 counts/min. We obtained various high-resolution phantom images for alpha particles with the developed system. We conclude that the developed imaging detector is promising for high-resolution distribution measurements of alpha particles.
Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.
Elleaume, P; Fortgang, C; Penel, C; Tarazona, E
1995-09-01
A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.
Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot
NASA Technical Reports Server (NTRS)
Lane, John
2013-01-01
The optical extinction of a laser due to scattering of particles is a well-known phenomenon. In a laboratory environment, this physical principle is known as the Beer-Lambert law, and is often used to measure the concentration of scattering particles in a fluid or gas. This method has been experimentally shown to be a usable means to measure the dust density from a rocket plume interaction with the lunar surface. Using the same principles and experimental arrangement, this technique can be applied to hydrometeor size distributions, and for launch-pad operations, specifically as a passive hail detection and measurement system. Calibration of a hail monitoring system is a difficult process. In the past, it has required comparison to another means of measuring hydrometeor size and density. Using a technique recently developed for estimating the density of surface dust dispersed during a rocket landing, measuring the extinction of a laser passing through hail (or dust in the rocket case) yields an estimate of the second moment of the particle cloud, and hydrometeor size distribution in the terrestrial meteorological case. With the exception of disdrometers, instruments that measure rain and hail fall make indirect measurements of the drop-size distribution. Instruments that scatter microwaves off of hydrometeors, such as the WSR-88D (Weather Surveillance Radar 88 Doppler), vertical wind profilers, and microwave disdrometers, measure the sixth moment of the drop size distribution (DSD). By projecting a laser onto a target, changes in brightness of the laser spot against the target background during rain and hail yield a measurement of the DSD's second moment by way of the Beer-Lambert law. In order to detect the laser attenuation within the 8-bit resolution of most camera image arrays, a minimum path length is required. Depending on the intensity of the hail fall rate for moderate to heavy rainfall, a laser path length of 100 m is sufficient to measure variations in optical extinction using a digital camera. For hail fall only, the laser path may be shorter because of greater scattering due to the properties of hailstones versus raindrops. A photodetector may replace the camera in automated installations. Laser-based rain and hail measurement systems are available, but they are based on measuring the interruption of a thin laser beam, thus counting individual hydrometeors. These systems are true disdrometers since they also measure size and velocity. The method reported here is a simple method, requiring far less processing, but it is not a disdrometer.
Wolstencroft, J; Robinson, L; Srinivasan, R; Kerry, E; Mandy, W; Skuse, D
2018-07-01
Group social skills interventions (GSSIs) are a commonly offered treatment for children with high functioning ASD. We critically evaluated GSSI randomised controlled trials for those aged 6-25 years. Our meta-analysis of outcomes emphasised internal validity, thus was restricted to trials that used the parent-report social responsiveness scale (SRS) or the social skills rating system (SSRS). Large positive effect sizes were found for the SRS total score, plus the social communication and restricted interests and repetitive behaviours subscales. The SSRS social skills subscale improved with moderate effect size. Moderator analysis of the SRS showed that GSSIs that include parent-groups, and are of greater duration or intensity, obtained larger effect sizes. We recommend future trials distinguish gains in children's social knowledge from social performance.
NASA Technical Reports Server (NTRS)
Bielawa, Richard L.; Hefner, Rachel E.; Castagna, Andre
1991-01-01
The results are presented of an analytic and experimental research program involving a Sikorsky S-55 helicopter tail cone directed ultimately to the improved structural analysis of airframe substructures typical of moderate sized helicopters of metal semimonocoque construction. Experimental static strain and dynamic shake-testing measurements are presented. Correlation studies of each of these tests with a PC-based finite element analysis (COSMOS/M) are described. The tests included static loadings at the end of the tail cone supported in the cantilever configuration as well as vibrational shake-testing in both the cantilever and free-free configurations.
Schwalbe, Craig; Gearing, Robin
2012-01-01
Poor adherence of children and adolescents to evidence-based psychosocial interventions remains a fundamental impediment to treatment effectiveness. To maintain client adherence, researchers and clinicians have employed a number of adherence-promoting strategies, from telephone calls and letters to providing transportation costs and child care to motivational enhancement therapies. However, the influence of adherence promoters on intervention outcomes has not been reported. This study examined the moderating effect of adherence-promoting strategies in a survey and meta-analysis of randomized clinical trials of cognitive behavioral treatments, interpersonal therapy, and psycho-education for children and adolescents with mental health problems (k = 33). Results indicated the type and intensity of adherence promoters' moderated study effect sizes according to client characteristics (age, gender, diagnosis). Preliminary findings suggest that males had higher effect sizes when more intensive adherence-promoting efforts were employed. Adherence-promoting efforts were associated with lower effect sizes for youths who were diagnosed with externalizing disorders. Results of this study suggest directions for future research to clarify clinical guidelines to maximize retention in evidence-based psychotherapy. © 2012 American Orthopsychiatric Association.
Yuchang, Jin; Junyi, Li; Junxiu, An; Jing, Wu; Mingcheng, He
2017-01-01
Traditional bullying and cyberbullying have become serious worldwide issues. The meta-analysis in this article took a cross-cultural perspective to explore whether there were any differences between the effects of cyber victimization and traditional victimization on the presence of depression and anxiety in children and adolescents and to examine the effects of moderators in explaining these differences/similarities. Fifty-six empirical studies (generating 148 independent samples) were included with a total sample size of 214,819 participants. The results indicated that the effects of cyber victimization and the subtypes of traditional victimization on anxiety were significantly different, and there was a marginally significant difference for depression. The moderating effects of country of origin were found to be significant for depression, with the mean effect size in North America being significantly higher than in China and Europe, which suggested that culture was an important factor. The moderating effects of age were also found to be significant for the relationships between traditional victimization and depression, traditional victimization and anxiety, cyber victimization and depression, and cyber victimization and anxiety. In addition, the effect size for cyber victimization and depression has increased in more recent publication years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ben-Naim, Eli; Krapivsky, Paul
Here we generalize the ordinary aggregation process to allow for choice. In ordinary aggregation, two random clusters merge and form a larger aggregate. In our implementation of choice, a target cluster and two candidate clusters are randomly selected and the target cluster merges with the larger of the two candidate clusters.We study the long-time asymptotic behavior and find that as in ordinary aggregation, the size density adheres to the standard scaling form. However, aggregation with choice exhibits a number of different features. First, the density of the smallest clusters exhibits anomalous scaling. Second, both the small-size and the large-size tailsmore » of the density are overpopulated, at the expense of the density of moderate-size clusters. Finally, we also study the complementary case where the smaller candidate cluster participates in the aggregation process and find an abundance of moderate clusters at the expense of small and large clusters. Additionally, we investigate aggregation processes with choice among multiple candidate clusters and a symmetric implementation where the choice is between two pairs of clusters.« less
NASA Astrophysics Data System (ADS)
Sacks, L. E.; Edgar, L. A.; Edwards, C. S.; Anderson, R. B.
2016-12-01
Images acquired by the Mars Hand Lens Imager (MAHLI) and the ChemCam Remote Micro Imager (RMI) onboard the Mars Science Laboratory (MSL) Curiosity rover provide grain-scale data that are critical for interpreting sedimentary deposits. At the location informally known as Marias Pass, Curiosity used both cameras to image the nine rock targets used in this study. We used manual point-counts to measure grain size distributions from those images to compare the abilities of the two cameras. The manually derived results were compared to automated grain size data obtained using pyDGS (Digital Grain Size), an open-source python program. Grain size analyses were used to test the lacustrine and aeolian depositional hypotheses for the Murray and Stimson formations at Marias Pass. Results indicate that the MAHLI and RMI instruments, despite their different fields of view and properties, provide comparable grain size measurements. Additionally, pyDGS does not account for grains smaller than a few pixels and thus does not report representative grain size data and should not be used on images with a large fraction of unresolved grains. Finally, the data collected at Marias Pass are consistent with the existing interpretations of the Murray and Stimson formations. The fine-grained results of the Murray formation analyses support lacustrine deposition, while the mean grain size of the Stimson formation is fine to medium sized sand, consistent with aeolian deposition. However, directly above the contact with the Murray formation, larger rip-up clasts of the Murray formation are present in the Stimson formation. It is possible that water was involved at this stage of erosion and re-deposition, prior to aeolian deposition. Additionally, the grain-scale analyses conducted in this study show that the Dust Removal Tool on Curiosity should be used prior to capturing images for grain-scale analysis. Two images of the target informally named Ronan, taken before and after brushing, resulted in dramatically different grain size results, suggesting that the common, thin layer of dust obscured the true grain size distribution. These grain-scale analyses at Marias Pass have important implications for the collection and processing of image data, as well as the depositional environments recorded in Gale crater. Funded by NSF Grant AST-1461200
Schopper, Melissa A; Walkup, Laura L; Tkach, Jean A; Higano, Nara S; Lim, Foong Yen; Haberman, Beth; Woods, Jason C; Kingma, Paul S
2017-09-01
To evaluate postnatal lung volume in infants with congenital diaphragmatic hernia (CDH) and determine if a compensatory increase in lung volume occurs during the postnatal period. Using a novel pulmonary magnetic resonance imaging method for imaging neonatal lungs, the postnatal lung volumes in infants with CDH were determined and compared with prenatal lung volumes obtained via late gestation magnetic resonance imaging. Infants with left-sided CDH (2 mild, 9 moderate, and 1 severe) were evaluated. The total lung volume increased in all infants, with the contralateral lung increasing faster than the ipsilateral lung (mean ± SD: 4.9 ± 3.0 mL/week vs 3.4 ± 2.1 mL/week, P = .005). In contrast to prenatal studies, the volume of lungs of infants with more severe CDH grew faster than the lungs of infants with more mild CDH (Spearman's ρ=-0.086, P = .01). Although the contralateral lung volume grew faster in both mild and moderate groups, the majority of total lung volume growth in moderate CDH came from increased volume of the ipsilateral lung (42% of total lung volume increase in the moderate group vs 32% of total lung volume increase in the mild group, P = .09). Analysis of multiple clinical variables suggests that increased weight gain was associated with increased compensatory ipsilateral lung volume growth (ρ = 0.57, P = .05). These results suggest a potential for postnatal catch-up growth in infants with pulmonary hypoplasia and suggest that weight gain may increase the volume growth of the more severely affected lung. Copyright © 2017 Elsevier Inc. All rights reserved.
McBride, Colleen M; Blocklin, Michelle; Lipkus, Isaac M; Klein, William M P; Brandon, Thomas H
2017-01-01
To understand whether patient-reported experiences with lung cancer may create teachable moments (TM) for their relatives as evidenced by shifts in their risk perceptions, affective response, and self-image and in turn, motivation to quit smoking. Patients at a comprehensive cancer center (n = 152) completed a survey within 6 months of lung cancer diagnosis to assess their cancer-related symptoms and openness and enumerated relatives who were smokers. Relative smokers (n = 218) then completed a survey assessing their risk perceptions, affective response, and self-image as a smoker related to the patient's diagnosis (TM mechanisms), and their motivation to quit smoking. Cross-sectional mediation and moderation analyses were conducted to explore the links between patient-reported experiences, and relatives' TM mechanisms, and motivation to quit smoking. Relative-reported affect was a significant mediator of the association between patient-reported symptoms and relative smoker's desire to quit. Relatives' self-image was a significant moderator of the association between patient-reported symptoms and relative smoker's desire to quit, such that patients' reported symptoms were associated with relatives' desire to quit only when the relative smoker reported a generally positive self-image as a smoker. No evidence was found for moderated mediation. However, the link between symptoms and negative affect was moderated by perceptions of risk. Whether smokers experience a family member's lung cancer as a TM is influenced by multiple interrelated cognitive and affective factors that warrant further exploration. Clearer understanding of these factors could inform how to re-invigorate and sustain this motivation to promote concrete actions toward smoking cessation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Peller, Joseph A.; Ceja, Nancy K.; Wawak, Amanda J.; Trammell, Susan R.
2018-02-01
Polarized light imaging and optical spectroscopy can be used to distinguish between healthy and diseased tissue. In this study, the design and testing of a single-pixel hyperspectral imaging system that uses differences in the polarization of light reflected from tissue to differentiate between healthy and thermally damaged tissue is discussed. Thermal lesions were created in porcine skin (n = 8) samples using an IR laser. The damaged regions were clearly visible in the polarized light hyperspectral images. Reflectance hyperspectral and white light imaging was also obtained for all tissue samples. Sizes of the thermally damaged regions as measured via polarized light hyperspectral imaging are compared to sizes of these regions as measured in the reflectance hyperspectral images and white light images. Good agreement between the sizes measured by all three imaging modalities was found. Hyperspectral polarized light imaging can differentiate between healthy and damaged tissue. Possible applications of this imaging system include determination of tumor margins during cancer surgery or pre-surgical biopsy.
Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M
2017-03-01
To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Thompson, J E; van Leeuwen, P J; Moses, D; Shnier, R; Brenner, P; Delprado, W; Pulbrook, M; Böhm, M; Haynes, A M; Hayen, A; Stricker, P D
2016-05-01
We assess the accuracy of multiparametric magnetic resonance imaging for significant prostate cancer detection before diagnostic biopsy in men with an abnormal prostate specific antigen/digital rectal examination. A total of 388 men underwent multiparametric magnetic resonance imaging, including T2-weighted, diffusion weighted and dynamic contrast enhanced imaging before biopsy. Two radiologists used PI-RADS to allocate a score of 1 to 5 for suspicion of significant prostate cancer (Gleason 7 with more than 5% grade 4). PI-RADS 3 to 5 was considered positive. Transperineal template guided mapping biopsy of 18 regions (median 30 cores) was performed with additional manually directed cores from magnetic resonance imaging positive regions. The anatomical location, size and grade of individual cancer areas in the biopsy regions (18) as the primary outcome and in prostatectomy specimens (117) as the secondary outcome were correlated to the magnetic resonance imaging positive regions. Of the 388 men who were enrolled in the study 344 were analyzed. Multiparametric magnetic resonance imaging was positive in 77.0% of patients, 62.5% had prostate cancer and 41.6% had significant prostate cancer. The detection of significant prostate cancer by multiparametric magnetic resonance imaging had a sensitivity of 96%, specificity of 36%, negative predictive value of 92% and positive predictive value of 52%. Adding PI-RADS to the multivariate model, including prostate specific antigen, digital rectal examination, prostate volume and age, improved the AUC from 0.776 to 0.879 (p <0.001). Anatomical concordance analysis showed a low mismatch between the magnetic resonance imaging positive regions and biopsy positive regions (4 [2.9%]), and the significant prostate cancer area in the radical prostatectomy specimen (3 [3.3%]). In men with an abnormal prostate specific antigen/digital rectal examination, multiparametric magnetic resonance imaging detected significant prostate cancer with an excellent negative predictive value and moderate positive predictive value. The use of multiparametric magnetic resonance imaging to diagnose significant prostate cancer may result in a substantial number of unnecessary biopsies while missing a minimum of significant prostate cancers. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Sookpeng, S; Martin, C J; Gentle, D J; Lopez-Gonzalez, M R
2014-03-01
Automatic tube current modulation (ATCM) systems are now used for the majority of CT scans. The principles of ATCM operation are different in CT scanners from different manufacturers. Toshiba and GE scanners base the current modulation on a target noise setting, while Philips and Siemens scanners use reference image and reference mAs concepts respectively. Knowledge of the relationships between patient size, dose and image noise are important for CT patient dose optimisation. In this study, the CT patient doses were surveyed for 14 CT scanners from four different CT scanner manufacturers. The patient cross sectional area, the tube current modulation and the image noise from the CT images were analysed using in-house software. The Toshiba and GE scanner results showed that noise levels are relatively constant but tube currents are dependent on patient size. As a result of this there is a wide range in tube current values across different patient sizes, and doses for large patients are significantly higher in these scanners. In contrast, in the Philips and Siemens scanners, tube currents are less dependent on patient size, the range in tube current is narrower, and the doses for larger patients are not as high. Image noise is more dependent on the patient size.
The economic burden of prematurity in Canada.
Johnston, Karissa M; Gooch, Katherine; Korol, Ellen; Vo, Pamela; Eyawo, Oghenowede; Bradt, Pamela; Levy, Adrian
2014-04-05
Preterm birth is a major risk factor for morbidity and mortality among infants worldwide, and imposes considerable burden on health, education and social services, as well as on families and caregivers. Morbidity and mortality resulting from preterm birth is highest among early (< 28 weeks gestational age) and moderate (28-32 weeks) preterm infants, relative to late preterm infants (33-36 weeks). However, substantial societal burden is associated with late prematurity due to the larger number of late preterm infants relative to early and moderate preterm infants. The aim in this study was to characterize the burden of premature birth in Canada for early, moderate, and late premature infants, including resource utilization, direct medical costs, parental out-of-pocket costs, education costs, and mortality, using a validated and published decision model from the UK, and adapting it to a Canadian setting based on analysis of administrative, population-based data from Québec. Two-year survival was estimated at 56.0% for early preterm infants, 92.8% for moderate preterm infants, and 98.4% for late preterm infants. Per infant resource utilization consistently decreased with age. For moderately preterm infants, hospital days ranged from 1.6 at age two to 0.09 at age ten. Cost per infant over the first ten years of life was estimated to be $67,467 for early preterm infants, $52,796 for moderate preterm infants, and $10,010 for late preterm infants. Based on population sizes this corresponds to total national costs of $123.3 million for early preterm infants, $255.6 million for moderate preterm infants, $208.2 million for late preterm infants, and $587.1 million for all infants. Premature birth results in significant infant morbidity, mortality, healthcare utilization and costs in Canada. A comprehensive decision-model based on analysis of a Canadian population-based administrative data source suggested that the greatest national-level burden is associated with moderate preterm infants due to both a large cost per infant and population size while the highest individual-level burden is in early preterm infants and the largest total population size is in late preterm infants. Although the highest medical costs are incurred during the neonatal period, greater resource utilization and costs extend into childhood.
Fairchild, Amanda J.; McQuillin, Samuel D.
2017-01-01
Third variable effects elucidate the relation between two other variables, and can describe why they are related or under what conditions they are related. This article demonstrates methods to analyze two third-variable effects: moderation and mediation. The utility of examining moderation and mediation effects in school psychology is described and current use of the analyses in applied school psychology research is reviewed and evaluated. Proper statistical methods to test the effects are presented, and different effect size measures for the models are provided. Extensions of the basic moderator and mediator models are also described. PMID:20006988
Fairchild, Amanda J; McQuillin, Samuel D
2010-02-01
Third variable effects elucidate the relation between two other variables, and can describe why they are related or under what conditions they are related. This article demonstrates methods to analyze two third-variable effects: moderation and mediation. The utility of examining moderation and mediation effects in school psychology is described and current use of the analyses in applied school psychology research is reviewed and evaluated. Proper statistical methods to test the effects are presented, and different effect size measures for the models are provided. Extensions of the basic moderator and mediator models are also described.
Warren, Cortney S; Castillo, Linda G; Gleaves, David H
2010-01-01
White American cultural values of appearance are implicated in the development of body dissatisfaction. This study examined whether the relationships between awareness of White American appearance ideals, internalization of such ideals, and body dissatisfaction are moderated by behavioral acculturation and attitudinal marginalization in a sample of 94 Mexican American women. Results indicated that behavioral acculturation moderated the relationship between awareness and internalization and cognitive marginalization moderated the relationship between internalization and body dissatisfaction. Body size was positively correlated with body dissatisfaction and negatively correlated with behavioral acculturation. These findings have important implications for clinical practice and research with Mexican American women.
SPECT brain perfusion findings in mild or moderate traumatic brain injury.
Abu-Judeh, H H; Parker, R; Aleksic, S; Singh, M L; Naddaf, S; Atay, S; Kumar, M; Omar, W; El-Zeftawy, H; Luo, J Q; Abdel-Dayem, H M
2000-01-01
The purpose of this manuscript is to present the findings in the largest series of SPECT brain perfusion imaging reported to date for mild or moderate traumatic brain injury. This is a retrospective evaluation of 228 SPECT brain perfusion-imaging studies of patients who suffered mild or moderate traumatic brain injury with or without loss of consciousness (LOC). All patients had no past medical history of previous brain trauma, neurological, or psychiatric diseases, HIV, alcohol or drug abuse. The patient population included 135 males and 93 females. The ages ranged from 11-88 years (mean 40.8). The most common complaints were characteristic of the postconcussion syndrome: headaches 139/228 (61%); dizziness 61/228 (27%); and memory problems 63/228 (28%). LOC status was reported to be positive in 121/228 (53%), negative in 41/228 (18%), and unknown for 63/228 (28%). Normal studies accounted for 52/228 (23%). For abnormal studies (176/228 or 77%) the findings were as follows: basal ganglia hypoperfusion 338 lesions (55.2%); frontal lobe hypoperfusion 146 (23.8%); temporal lobes hypoperfusion 80 (13%); parietal lobes hypoperfusion 20 (3.7%); insular and or occipital lobes hypoperfusion 28 (4.6%). Patients' symptoms correlated with the SPECT brain perfusion findings. The SPECT BPI studies in 122/228 (54%) were done early within 3 months of the date of the accident, and for the remainder, 106/228 (46%) over 3 months and less than 3 years from the date of the injury. In early imaging, 382 lesions were detected; in 92 patients (average 4.2 lesions per study) imaging after 3 months detected 230 lesions: in 84 patients (average 2.7 lesions per study). Basal ganglia hypoperfusion is the most common abnormality following mild or moderate traumatic brain injury (p = 0.006), and is more common in patients complaining of memory problem (p = 0.0005) and dizziness (p = 0.003). Early imaging can detect more lesions than delayed imaging (p = 0.0011). SPECT brain perfusion abnormalities can occur in the absence of LOC.
Vadnais, Carolyn; Stensaas, Gregory
2014-01-01
Under the National Land Imaging Requirements (NLIR) Project, the U.S. Geological Survey (USGS) is developing a functional capability to obtain, characterize, manage, maintain and prioritize all Earth observing (EO) land remote sensing user requirements. The goal is a better understanding of community needs that can be supported with land remote sensing resources, and a means to match needs with appropriate solutions in an effective and efficient way. The NLIR Project is composed of two components. The first component is focused on the development of the Earth Observation Requirements Evaluation System (EORES) to capture, store and analyze user requirements, whereas, the second component is the mechanism and processes to elicit and document the user requirements that will populate the EORES. To develop the second component, the requirements elicitation methodology was exercised and refined through a pilot project conducted from June to September 2013. The pilot project focused specifically on applications and user requirements for moderate resolution imagery (5–120 meter resolution) as the test case for requirements development. The purpose of this summary report is to provide a high-level overview of the requirements elicitation process that was exercised through the pilot project and an early analysis of the moderate resolution imaging user requirements acquired to date to support ongoing USGS sustainable land imaging study needs. The pilot project engaged a limited set of Federal Government users from the operational and research communities and therefore the information captured represents only a subset of all land imaging user requirements. However, based on a comparison of results, trends, and analysis, the pilot captured a strong baseline of typical applications areas and user needs for moderate resolution imagery. Because these results are preliminary and represent only a sample of users and application areas, the information from this report should only be used to indicate general user needs for the applications covered. Users of the information are cautioned that use of specific numeric results may be inappropriate without additional research. Any information used or cited from this report should specifically be cited as preliminary findings.
NASA Technical Reports Server (NTRS)
Huang, Dong; Yang, Wenze; Tan, Bin; Rautiainen, Miina; Zhang, Ping; Hu, Jiannan; Shabanov, Nikolay V.; Linder, Sune; Knyazikhin, Yuri; Myneni, Ranga B.
2006-01-01
The validation of moderate-resolution satellite leaf area index (LAI) products such as those operationally generated from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor data requires reference LAI maps developed from field LAI measurements and fine-resolution satellite data. Errors in field measurements and satellite data determine the accuracy of the reference LAI maps. This paper describes a method by which reference maps of known accuracy can be generated with knowledge of errors in fine-resolution satellite data. The method is demonstrated with data from an international field campaign in a boreal coniferous forest in northern Sweden, and Enhanced Thematic Mapper Plus images. The reference LAI map thus generated is used to assess modifications to the MODIS LAI/fPAR algorithm recently implemented to derive the next generation of the MODIS LAI/fPAR product for this important biome type.
General and program-specific moderators of two eating disorder prevention programs.
Stice, Eric; Marti, Nathan; Shaw, Heather; O'Neil, Kelly
2008-11-01
To investigate general and program-specific factors hypothesized to moderate the effects of two eating disorder prevention programs. High-risk adolescent girls (N = 481; M age = 17) were randomized to a dissonance-based thin-ideal internalization reduction program, a healthy weight management program, an expressive-writing control condition, or an assessment-only control condition. Participants completed diagnostic interviews and surveys at pretest, post-test, 6-month follow-up, and 12-month follow-up. Dissonance program effects on bulimic symptoms were stronger for participants with initial elevations in body image distress, bulimic symptoms, and thin-ideal internalization. Healthy weight program effects on bulimic symptoms were stronger for adolescents with initial elevations in body image distress, bulimic symptoms, readiness to change, body mass, and emotional eating. Overall, intervention effects tended to be amplified for high-risk versus low-risk adolescents. However, certain moderator effects appeared to be specific to the two different prevention programs.
Gender Differences in Figural Matrices: The Moderating Role of Item Design Features
ERIC Educational Resources Information Center
Arendasy, Martin E.; Sommer, Markus
2012-01-01
There is a heated debate on whether observed gender differences in some figural matrices in adults can be attributed to gender differences in inductive reasoning/G[subscript f] or differential item functioning and/or test bias. Based on previous studies we hypothesized that three specific item design features moderate the effect size of the gender…
Knieps, Melanie; Granhag, Pär A; Vrij, Aldert
2014-01-01
Prospection is thinking about possible future states of the world. Commitment to perform a future action-commonly referred to as intention-is a specific type of prospection. This knowledge is relevant when trying to assess whether a stated intention is a lie or the truth. An important observation is that thinking of, and committing to, future actions often evoke vivid and detailed mental images. One factor that affects how specific a person experiences these simulations is location-familiarity. The purpose of this study was to examine to what extent location-familiarity moderates how liars and truth tellers describe a mental image in an investigative interview. Liars were instructed to plan a criminal act and truth tellers were instructed to plan a non-criminal act. Before they could carry out these acts, the participants were intercepted and interviewed about the mental images they may have had experienced in this planning phase. Truth tellers told the truth whereas liars used a cover story to mask their criminal intentions. As predicted, the results showed that the truth tellers reported a mental image significantly more often than the liars. If a mental image was reported, the content of the descriptions did not differ between liars and truth tellers. In a post interview questionnaire, the participants rated the vividness (i.e., content and clarity) of their mental images. The ratings revealed that the truth tellers had experienced their mental images more vividly during the planning phase than the liars. In conclusion, this study indicates that both prototypical and specific representations play a role in prospection. Although location-familiarity did not moderate how liars and truth tellers describe their mental images of the future, this study allows some interesting insights into human future thinking. How these findings can be helpful for distinguishing between true and false intentions will be discussed.
Knieps, Melanie; Granhag, Pär A.; Vrij, Aldert
2014-01-01
Prospection is thinking about possible future states of the world. Commitment to perform a future action—commonly referred to as intention—is a specific type of prospection. This knowledge is relevant when trying to assess whether a stated intention is a lie or the truth. An important observation is that thinking of, and committing to, future actions often evoke vivid and detailed mental images. One factor that affects how specific a person experiences these simulations is location-familiarity. The purpose of this study was to examine to what extent location-familiarity moderates how liars and truth tellers describe a mental image in an investigative interview. Liars were instructed to plan a criminal act and truth tellers were instructed to plan a non-criminal act. Before they could carry out these acts, the participants were intercepted and interviewed about the mental images they may have had experienced in this planning phase. Truth tellers told the truth whereas liars used a cover story to mask their criminal intentions. As predicted, the results showed that the truth tellers reported a mental image significantly more often than the liars. If a mental image was reported, the content of the descriptions did not differ between liars and truth tellers. In a post interview questionnaire, the participants rated the vividness (i.e., content and clarity) of their mental images. The ratings revealed that the truth tellers had experienced their mental images more vividly during the planning phase than the liars. In conclusion, this study indicates that both prototypical and specific representations play a role in prospection. Although location-familiarity did not moderate how liars and truth tellers describe their mental images of the future, this study allows some interesting insights into human future thinking. How these findings can be helpful for distinguishing between true and false intentions will be discussed. PMID:25071648
Klimza, Hanna; Jackowska, Joanna; Piazza, Cesare; Banaszewski, Jacek; Wierzbicka, Malgorzata
2018-03-01
Trans-oral laser microsurgery is an established technique for the treatment of early and moderately advanced laryngeal cancer. The authors intend to test the usefulness of narrow-band imaging in the intraoperative assessment of the larynx mucosa in terms of specifying surgical margins. Forty-four consecutive T1-T2 glottic cancers treated with trans-oral laser microsurgery Type I-VI cordectomy were presented. Suspected areas (90 samples/44 patients) were biopsied under the guidance of narrow-band imaging and white light and sent for frozen section. Our study revealed that 75 of 90 (83.3%) white light and narrow-band imaging-guided samples were histopathologically positive: 30 (40%) were confirmed as carcinoma in situ or invasive carcinoma and 45 (60%) as moderate to severe dysplasia. In 6 patients mucosa was suspected only in narrow-band imaging, with no suspicion under white light. Thus, in these 6 patients 18/90 (20%) samples were taken. In 5/6 patients 16/18 (88.8%) samples were positive in frozen section: in 6/18 (33.3%) carcinoma (2 patients), 10/18 (66.6%) severe dysplasia was confirmed (3 patients). In 1 patient 2/18 (11.1%) samples were negative in frozen section. Presented analysis showed, that sensitivity, specificity and accuracy of white light was 79.5%, 20% and 71.1% respectively, while narrow-band imaging was 100%, 0.0% and 85.7%, respectively. The intraoperative use of narrow-band imaging proved to be valuable in the visualization of suspect areas of the mucosa. Narrow-band imaging confirms the suspicions undertaken in white light and importantly, it showed microlesions beyond the scope of white light. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Multiparametric Quantitative Ultrasound Imaging in Assessment of Chronic Kidney Disease.
Gao, Jing; Perlman, Alan; Kalache, Safa; Berman, Nathaniel; Seshan, Surya; Salvatore, Steven; Smith, Lindsey; Wehrli, Natasha; Waldron, Levi; Kodali, Hanish; Chevalier, James
2017-11-01
To evaluate the value of multiparametric quantitative ultrasound imaging in assessing chronic kidney disease (CKD) using kidney biopsy pathologic findings as reference standards. We prospectively measured multiparametric quantitative ultrasound markers with grayscale, spectral Doppler, and acoustic radiation force impulse imaging in 25 patients with CKD before kidney biopsy and 10 healthy volunteers. Based on all pathologic (glomerulosclerosis, interstitial fibrosis/tubular atrophy, arteriosclerosis, and edema) scores, the patients with CKD were classified into mild (no grade 3 and <2 of grade 2) and moderate to severe (at least 2 of grade 2 or 1 of grade 3) CKD groups. Multiparametric quantitative ultrasound parameters included kidney length, cortical thickness, pixel intensity, parenchymal shear wave velocity, intrarenal artery peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index. We tested the difference in quantitative ultrasound parameters among mild CKD, moderate to severe CKD, and healthy controls using analysis of variance, analyzed correlations of quantitative ultrasound parameters with pathologic scores and the estimated glomerular filtration rate (GFR) using Pearson correlation coefficients, and examined the diagnostic performance of quantitative ultrasound parameters in determining moderate CKD and an estimated GFR of less than 60 mL/min/1.73 m 2 using receiver operating characteristic curve analysis. There were significant differences in cortical thickness, pixel intensity, PSV, and EDV among the 3 groups (all P < .01). Among quantitative ultrasound parameters, the top areas under the receiver operating characteristic curves for PSV and EDV were 0.88 and 0.97, respectively, for determining pathologic moderate to severe CKD, and 0.76 and 0.86 for estimated GFR of less than 60 mL/min/1.73 m 2 . Moderate to good correlations were found for PSV, EDV, and pixel intensity with pathologic scores and estimated GFR. The PSV, EDV, and pixel intensity are valuable in determining moderate to severe CKD. The value of shear wave velocity in assessing CKD needs further investigation. © 2017 by the American Institute of Ultrasound in Medicine.
Mapping Snow Grain Size over Greenland from MODIS
NASA Technical Reports Server (NTRS)
Lyapustin, Alexei; Tedesco, Marco; Wang, Yujie; Kokhanovsky, Alexander
2008-01-01
This paper presents a new automatic algorithm to derive optical snow grain size (SGS) at 1 km resolution using Moderate Resolution Imaging Spectroradiometer (MODIS) measurements. Differently from previous approaches, snow grains are not assumed to be spherical but a fractal approach is used to account for their irregular shape. The retrieval is conceptually based on an analytical asymptotic radiative transfer model which predicts spectral bidirectional snow reflectance as a function of the grain size and ice absorption. The analytical form of solution leads to an explicit and fast retrieval algorithm. The time series analysis of derived SGS shows a good sensitivity to snow metamorphism, including melting and snow precipitation events. Preprocessing is performed by a Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm, which includes gridding MODIS data to 1 km resolution, water vapor retrieval, cloud masking and an atmospheric correction. MAIAC cloud mask (CM) is a new algorithm based on a time series of gridded MODIS measurements and an image-based rather than pixel-based processing. Extensive processing of MODIS TERRA data over Greenland shows a robust performance of CM algorithm in discrimination of clouds over bright snow and ice. As part of the validation analysis, SGS derived from MODIS over selected sites in 2004 was compared to the microwave brightness temperature measurements of SSM\\I radiometer, which is sensitive to the amount of liquid water in the snowpack. The comparison showed a good qualitative agreement, with both datasets detecting two main periods of snowmelt. Additionally, MODIS SGS was compared with predictions of the snow model CROCUS driven by measurements of the automatic whether stations of the Greenland Climate Network. We found that CROCUS grain size is on average a factor of two larger than MODIS-derived SGS. Overall, the agreement between CROCUS and MODIS results was satisfactory, in particular before and during the first melting period in mid-June. Following detailed time series analysis of SGS for four permanent sites, the paper presents SGS maps over the Greenland ice sheet for the March-September period of 2004.
Barbagelata, Alejandro; Di Carli, Marcelo F; Califf, Robert M; Garg, Jyotsna; Birnbaum, Yochai; Grinfeld, Liliana; Gibbons, Raymond J; Granger, Christopher B; Goodman, Shaun G; Wagner, Galen S; Mahaffey, Kenneth W
2005-10-01
Noninvasive methods are needed to evaluate reperfusion success in patients with acute myocardial infarction (MI). The AMISTAD trial was analyzed to compare MI size and myocardial salvage determined by electrocardiogram (ECG) with technetium Tc 99m sestamibi single-photon emission computerized tomography (SPECT) imaging. Of 236 patients enrolled in AMISTAD, 166 (70 %) with no ECG confounding factors and no prior MI were included in this analysis. Of these, group 1 (126 patients, 53%) had final infarct size (FIS) available by both ECG and SPECT. Group 2 (56 patients, 24%) had myocardium at risk, FIS, and salvage index (SI) assessed by both SPECT and ECG techniques. Aldrich/Clemmensen scores for myocardium at risk and the Selvester QRS score for final MI size were used. Salvage index was calculated as follows: SI = (myocardium at risk-FIS)/(myocardium at risk). In group 1, FIS was 15% (6, 24) as measured by ECG and 11% (2, 27) as measured by SPECT. In the adenosine group, FIS was 12% (6, 21) and 11% (2, 22). In the placebo group, FIS was 16.5% (7.5, 24) and 11.5% (3.0, 38.5) by ECG and SPECT, respectively. The overall correlation between SPECT and ECG for FIS was 0.58 (P = .0001): 0.60 in the placebo group (P = .0001) and 0.54 (P = .0001) in the adenosine group. In group 2, myocardium at risk was 23% (17, 30) and 26% (10, 50) with ECG and SPECT, respectively (P = .0066). Final infarct size was 17% (6, 21) and 12% (1, 24) (P < .0001). The SI was 29% (-7, 57) and 46% (15, 79) with ECG and SPECT, respectively (P = .0510). The ECG measurement of infarct size has a moderate relationship with SPECT infarct size measurements in the population with available assessments. This ECG algorithm must further be validated on clinical outcomes.
This study applied a phenology-based land-cover classification approach across the Laurentian Great Lakes Basin (GLB) using time-series data consisting of 23 Moderate Resolution Imaging Spectroradiometer (MODIS) Normalized Difference Vegetation Index (NDVI) composite images (250 ...
The correlation of social support with mental health: A meta-analysis
Harandi, Tayebeh Fasihi; Taghinasab, Maryam Mohammad; Nayeri, Tayebeh Dehghan
2017-01-01
Background and aim Social support is an important factor that can affect mental health. In recent decades, many studies have been done on the impact of social support on mental health. The purpose of the present study is to investigate the effect size of the relationship between social support and mental health in studies in Iran. Methods This meta-analysis was carried out in studies that were performed from 1996 through 2015. Databases included SID and Magiran, the comprehensive portal of human sciences, Noor specialized magazine databases, IRANDOC, Proquest, PubMed, Scopus, ERIC, Iranmedex and Google Scholar. The keywords used to search these websites included “mental health or general health,” and “Iran” and “social support.” In total, 64 studies had inclusion criteria meta-analysis. In order to collect data used from a meta-analysis worksheet that was made by the researcher and for data analysis software, CMA-2 was used. Results The mean of effect size of the 64 studies in the fixed-effect model and random-effect model was obtained respectively as 0.356 and 0.330, which indicated the moderate effect size of social support on mental health. The studies did not have publication bias, and enjoyed a heterogeneous effect size. The target population and social support questionnaire were moderator variables, but sex, sampling method, and mental health questionnaire were not moderator variables. Conclusion Regarding relatively high effect size of the correlation between social support and mental health, it is necessary to predispose higher social support, especially for women, the elderly, patients, workers, and students. PMID:29038699
Pernod, Gilles; Caterino, Jeffrey; Maignan, Maxime; Tissier, Cindy; Kassis, Jeannine; Lazarchick, John
2017-01-01
Although diagnostic guidelines are similar, there is a huge difference in pulmonary embolism (PE) prevalence between the United States of America (US) and countries outside the USA (OUS) in the emergency care setting. In this study, we prospectively analyze patients' characteristics and differences in clinical care that may influence PE prevalence in different countries. An international multicenter prospective diagnostic study was conducted in a standard-of-care setting. Consecutive outpatients presenting to the emergency unit and suspected for PE were managed using the Wells score, STA-Liatest® D-Dimers and imaging. The prevalence of PE in the study was 7.9% in low and moderate risk patients. Among the 1060 patients with low or moderate pre-test probability (PTP), PE prevalence was four times higher in OUS (10.7%) than in the US (2.5%) (P < 0.0001). The mean number of imaging procedures performed for one new PE diagnosis was 3.3 in OUS vs 17 in the US (P < 0.001). Stopping investigation in the case of negative D-dimers (DD combined) with low/moderate PTP was more frequent in OUS (92.7%) than in the US (75.7%) (P < 0.01). Moreover, the use of imaging was much higher in the US (44.4% vs 19.2% in OUS) in the case of moderate PTP combined with negative DD. Differences between US and OUS PE prevalence in emergency setting might be explained by differences in patients' characteristics and mostly in care patterns. US physicians performed computed tomographic pulmonary angiography more often than in Europe in cases of low/moderate PTP combined with negative DD. ClinicalTrials.gov NCT01221805.
IMPACTS OF PATCH SIZE AND LANDSCAPE HETEROGENEITY ON THEMATIC IMAGE CLASSIFICATION ACCURACY
Impacts of Patch Size and Landscape Heterogeneity on Thematic Image Classification Accuracy.
Currently, most thematic accuracy assessments of classified remotely sensed images oily account for errors between the various classes employed, at particular pixels of interest, thu...
Full-field digital mammography image data storage reduction using a crop tool.
Kang, Bong Joo; Kim, Sung Hun; An, Yeong Yi; Choi, Byung Gil
2015-05-01
The storage requirements for full-field digital mammography (FFDM) in a picture archiving and communication system are significant, so methods to reduce the data set size are needed. A FFDM crop tool for this purpose was designed, implemented, and tested. A total of 1,651 screening mammography cases with bilateral FFDMs were included in this study. The images were cropped using a DICOM editor while maintaining image quality. The cases were evaluated according to the breast volume (1/4, 2/4, 3/4, and 4/4) in the craniocaudal view. The image sizes between the cropped image group and the uncropped image group were compared. The overall image quality and reader's preference were independently evaluated by the consensus of two radiologists. Digital storage requirements for sets of four uncropped to cropped FFDM images were reduced by 3.8 to 82.9 %. The mean reduction rates according to the 1/4-4/4 breast volumes were 74.7, 61.1, 38, and 24 %, indicating that the lower the breast volume, the smaller the size of the cropped data set. The total image data set size was reduced from 87 to 36.7 GB, or a 57.7 % reduction. The overall image quality and the reader's preference for the cropped images were higher than those of the uncropped images. FFDM mammography data storage requirements can be significantly reduced using a crop tool.
NASA Astrophysics Data System (ADS)
Chan, Heang-Ping; Helvie, Mark A.; Petrick, Nicholas; Sahiner, Berkman; Adler, Dorit D.; Blane, Caroline E.; Joynt, Lynn K.; Paramagul, Chintana; Roubidoux, Marilyn A.; Wilson, Todd E.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.
1999-05-01
A receiver operating characteristic (ROC) experiment was conducted to evaluate the effects of pixel size on the characterization of mammographic microcalcifications. Digital mammograms were obtained by digitizing screen-film mammograms with a laser film scanner. One hundred twelve two-view mammograms with biopsy-proven microcalcifications were digitized at a pixel size of 35 micrometer X 35 micrometer. A region of interest (ROI) containing the microcalcifications was extracted from each image. ROI images with pixel sizes of 70 micrometers, 105 micrometers, and 140 micrometers were derived from the ROI of 35 micrometer pixel size by averaging 2 X 2, 3 X 3, and 4 X 4 neighboring pixels, respectively. The ROI images were printed on film with a laser imager. Seven MQSA-approved radiologists participated as observers. The likelihood of malignancy of the microcalcifications was rated on a 10-point confidence rating scale and analyzed with ROC methodology. The classification accuracy was quantified by the area, Az, under the ROC curve. The statistical significance of the differences in the Az values for different pixel sizes was estimated with the Dorfman-Berbaum-Metz (DBM) method for multi-reader, multi-case ROC data. It was found that five of the seven radiologists demonstrated a higher classification accuracy with the 70 micrometer or 105 micrometer images. The average Az also showed a higher classification accuracy in the range of 70 to 105 micrometer pixel size. However, the differences in A(subscript z/ between different pixel sizes did not achieve statistical significance. The low specificity of image features of microcalcifications an the large interobserver and intraobserver variabilities may have contributed to the relatively weak dependence of classification accuracy on pixel size.
MODIS Retrieval of Dust Aerosol
NASA Technical Reports Server (NTRS)
Remer, Lorraine A.; Kaufman, Yoram J.; Tanre, Didier
2003-01-01
The MODerate resolution Imaging Spectroradiometer (MODIS) currently aboard both the Terra and Aqua satellites produces a suite of products designed to characterize global aerosol distribution, optical thickness and particle size. Never before has a space-borne instrument been able to provide such detailed information, operationally, on a nearly global basis every day. The three years of Terra-MODIS data have been validated by comparing with co-located AERONET observations of aerosol optical thickness and derivations of aerosol size parameters. Some 8000 comparison points located at 133 AERONET sites around the globe show that the MODIS aerosol optical thickness retrievals are accurate to within the pre-launch expectations. However, the validation in regions dominated by desert dust is less accurate than in regions dominated by fine mode aerosol or background marine sea salt. The discrepancy is most apparent in retrievals of aerosol size parameters over ocean. In dust situations, the MODIS algorithm tends to under predict particle size because the reflectances at top of atmosphere measured by MODIS exhibit the stronger spectral signature expected by smaller particles. This pattern is consistent with the angular and spectral signature of non-spherical particles. All possible aerosol models in the MODIS Look-Up Tables were constructed from Mie theory, assuming a spherical shape. Using a combination of MODIS and AERONET observations, in regimes dominated by desert dust, we construct phase functions, empirically, with no assumption of particle shape. These new phase functions are introduced into the MODIS algorithm, in lieu of the original options for large dust-like particles. The results will be analyzed and examined.
Herencia-Bueno, Karina E; Aldrovani, Marcela; Crivelaro, Roberta M; Thiesen, Roberto; Barros-Sobrinho, Alexandre A F; Claros-Chacaltana, Flor D Y; Padua, Ivan R M; Santos, Daniela M; Laus, José L
2018-05-01
To evaluate acetylation of histone H3, chromatin remodeling, nuclear size and shape, DNA ploidy, and distribution of nucleolus organizing regions (NORs) in corneal epithelial and stromal cells of diabetic and nondiabetic rats. Diabetes was induced by a single intraperitoneal injection of alloxan. All diabetic rats (n = 20) included in the study had 4 weeks of moderate-to-severe hyperglycemia (plasma glucose levels >400 mg/dL). Acetylated histone H3 levels were quantified in corneal tissue using a colorimetric assay. Chromatin remodeling, nuclear sizes (area/perimeter) and shapes (circularity), and DNA ploidies were evaluated from Feulgen-stained tissue sections using video image analysis. Distributions of NORs were studied in tissue sections impregnated with silver ions. Ophthalmic clinical parameters, including corneal sensitivity, were investigated. Twenty nondiabetic rats were used as controls. Acetylation of histone H3 was reduced in the corneas of the diabetic rats. Nuclei in corneal epithelial cells of diabetic rats compacted chromatin, increased in size, modified their shapes, and elevated DNA ploidy. The only nuclear change observed in the corneal stromal cells of diabetic rats was chromatin decompaction. The size of the silver-stained NOR did not differ between the study samples. The corneal sensitivity in diabetic rats was 51.8% lower than that in nondiabetic rats. The results of this study show that alloxan-induced diabetes altered the histone H3 acetylation pattern and compromised the chromatin supraorganization in corneal tissue/cells. Continued research is needed to understand the clinical and morphofunctional significance of changes in corneal cell nuclei of diabetic individuals.
Rodriguez-Merchan, E C; De La Corte-Rodriguez, H
2016-04-01
Radiosynovectomy (RS) reduces the number of haemarthroses and the synovial size in chronic haemophilic synovitis. The purpose of this study was to quantitatively compare the effectiveness of two types of RS (yttrium-90 vs. rhenium-186) in terms of the objective improvement of haemarthroses and synovial size. Seventy RSs were performed in 70 joints (44 elbows, 26 ankles) of 70 haemophiliacs diagnosed with chronic synovitis. Yttrium-90 was used in 21 joints and rhenium-186 was used in 49 joints. The mean patient age was 20.61 years. RS resulted in significant improvement in the three variables studied (six months before RS vs. six months after RS), namely in the number of episodes of haemarthrosis (67.8% improvement); the size of the synovium as measured by means of a clinical scale (43.8% improvement) and imaging techniques in millimetres (26.7% improvement). We did not find significant statistical differences between yttrium-90 and rhenium-186 regarding their efficacy. No correlation was found between the results and other variables: age, joint (ankle or elbow), presence or absence of radiological involvement, type of haemophilia (A or B), grade of haemophilia (mild, moderate or severe), previous haematological treatment (on demand or prophylaxis), and the presence or absence of inhibitor Yttrium-90 RS and rhenium-186 RS were equally effective in reducing the number of haemarthroses and the size of the synovium in ankles and elbows in the short-term (6 months). No correlation was found between the results and other patients' characteristics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Electromagnetic backscattering from freak waves in (1 + 1)-dimensional deep-water
NASA Astrophysics Data System (ADS)
Xie, Tao; Shen, Tao; William, Perrie; Chen, Wei; Kuang, Hai-Lan
2010-05-01
To study the electromagnetic (EM) backscatter characteristics of freak waves at moderate incidence angles, we establish an EM backscattering model for freak waves in (1 + 1)-dimensional deep water. The nonlinear interaction between freak waves and Bragg short waves is considered to be the basic hydrodynamic spectra modulation mechanism in the model. Numerical results suggest that the EM backscattering intensities of freak waves are less than those from the background sea surface at moderate incidence angles. The normalised radar cross sections (NRCSs) from freak waves are highly polarisation dependent, even at low incidence angles, which is different from the situation for normal sea waves; moreover, the NRCS of freak waves is more polarisation dependent than the background sea surface. NRCS discrepancies between freak waves and the background sea surface with using horizontal transmitting horizomtal (HH) polarisation are larger than those using vertical transmitting vertical (VV) polarisation, at moderate incident angles. NRCS discrepancies between freak waves and background sea surface decreases with the increase of incidence angle, in both HH and VV polarisation radars. As an application, in the synthetic-aperture radar (SAR) imaging of freak waves, we suggest that freak waves should have extremely low backscatter NRCSs for the freak wave facet with the strongest slope. Compared with the background sea surface, the freak waves should be darker in HH polarisation echo images than in VV echo images, in SAR images. Freak waves can be more easily detected from the background sea surface in HH polarisation images than in VV polarisation images. The possibility of detection of freak waves at low incidence angles is much higher than at high incidence angles.
Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W
2015-01-01
Objective: The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Methods: Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined “small pelvis” reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current–time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. Results: It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). Conclusion: The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. Advances in knowledge: The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose. PMID:26419892
Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.
O'Dell, Walter G; Gormaley, Anne K; Prida, David A
2017-12-01
Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-user variability. Automatic methods of vessel sizing have been developed for two-dimensional images but a fully three-dimensional (3D) method suitable for vessel sizing from volumetric X-ray computed tomography (CT) or magnetic resonance imaging has heretofore not been demonstrated and validated robustly. In this paper, we refined and objectively validated Gatortail, a method that creates a mathematical geometric 3D model of each branch in a vascular tree, simulates the appearance of the virtual vascular tree in a 3D CT image, and uses the similarity of the simulated image to a patient's CT scan to drive the optimization of the model parameters, including vessel size, to match that of the patient. The method was validated with a 2-dimensional virtual tree structure under deformation, and with a realistic 3D-printed vascular phantom in which the diameter of 64 branches were manually measured 3 times each. The phantom was then scanned on a conventional clinical CT imaging system and the images processed with the in-house software to automatically segment and mathematically model the vascular tree, label each branch, and perform the Gatortail optimization of branch size and trajectory. Previously proposed methods of vessel sizing using matched Gaussian filters and tubularity metrics were also tested. The Gatortail method was then demonstrated on the pulmonary arterial tree segmented from a human volunteer's CT scan. The standard deviation of the difference between the manually measured and Gatortail-based radii in the 3D physical phantom was 0.074 mm (0.087 in-plane pixel units for image voxels of dimension 0.85 × 0.85 × 1.0 mm) over the 64 branches, representing vessel diameters ranging from 1.2 to 7 mm. The linear regression fit gave a slope of 1.056 and an R 2 value of 0.989. These three metrics reflect superior agreement of the radii estimates relative to previously published results over all sizes tested. Sizing via matched Gaussian filters resulted in size underestimates of >33% over all three test vessels, while the tubularity-metric matching exhibited a sizing uncertainty of >50%. In the human chest CT data set, the vessel voxel intensity profiles with and without branch model optimization showed excellent agreement and improvement in the objective measure of image similarity. Gatortail has been demonstrated to be an automated, objective, accurate and robust method for sizing of vessels in 3D non-invasively from chest CT scans. We anticipate that Gatortail, an image-based approach to automatically compute estimates of blood vessel radii and trajectories from 3D medical images, will facilitate future quantitative evaluation of vascular response to disease and environmental insult and improve understanding of the biological mechanisms underlying vascular disease processes. © 2017 American Association of Physicists in Medicine.
Imaging of adrenal incidentalomas with PET using (11)C-metomidate and (18)F-FDG.
Minn, Heikki; Salonen, Anna; Friberg, Johan; Roivainen, Anne; Viljanen, Tapio; Långsjö, Jaakko; Salmi, Jorma; Välimäki, Matti; Någren, Kjell; Nuutila, Pirjo
2004-06-01
Our aim was to evaluate the use of PET with (11)C-metomidate and (18)F-FDG for the diagnosis of adrenal incidentalomas. Twenty-one patients underwent hormonal screening before dynamic imaging of the upper abdomen with (11)C-metomidate, and for 19 of these 21 patients, static (18)F-FDG imaging followed. Uptake of (11)C-metomidate and (18)F-FDG in incidentalomas was quantified and correlated with the hormonal work-up and the mass size on CT (median, 2.5 cm; range, 2-10 cm). The final diagnoses were hormonally active adenoma (n = 7), nonsecretory adenoma (n = 5), adrenocortical carcinoma (n = 1), pheochromocytoma (n = 2), benign noncortical tumor (n = 2), normal adrenal (n = 1), and malignant noncortical tumor (n = 3). Diagnosis was established at surgery (n = 9), percutaneous biopsy (n = 4), or follow-up (n = 8). The highest uptake of (11)C-metomidate, expressed as standardized uptake value (SUV), was found in adrenocortical carcinoma (SUV = 28.0), followed by active adenomas (median SUV = 12.7), nonsecretory adenomas (median SUV = 12.2), and noncortical tumors (median SUV = 5.7). Patients with adenomas had significantly higher tumor-to-normal-adrenal (11)C-metomidate SUV ratios than did patients with noncortical tumors. (18)F-FDG detected 2 of 3 noncortical malignancies but failed to detect adrenal metastases from renal cell carcinoma. All inactive and most active adenomas were difficult to detect with (18)F-FDG against background activity, whereas both pheochromocytomas and adrenocortical carcinoma showed slightly increased uptake of (18)F-FDG. There was no correlation between uptake of (11)C-metomidate or (18)F-FDG and mass size. (11)C-Metomidate is a promising PET tracer to identify incidentalomas of adrenocortical origin. (18)F-FDG should be reserved for patients with a moderate to high likelihood of neoplastic disease.
Kiloparsec-scale Dust Disks in High-redshift Luminous Submillimeter Galaxies
NASA Astrophysics Data System (ADS)
Hodge, J. A.; Swinbank, A. M.; Simpson, J. M.; Smail, I.; Walter, F.; Alexander, D. M.; Bertoldi, F.; Biggs, A. D.; Brandt, W. N.; Chapman, S. C.; Chen, C. C.; Coppin, K. E. K.; Cox, P.; Dannerbauer, H.; Edge, A. C.; Greve, T. R.; Ivison, R. J.; Karim, A.; Knudsen, K. K.; Menten, K. M.; Rix, H.-W.; Schinnerer, E.; Wardlow, J. L.; Weiss, A.; van der Werf, P.
2016-12-01
We present high-resolution (0.″16) 870 μm Atacama Large Millimeter/submillimeter Array (ALMA) imaging of 16 luminous ({L}{IR}˜ 4× {10}12 {L}⊙ ) submillimeter galaxies (SMGs) from the ALESS survey of the Extended Chandra Deep Field South. This dust imaging traces the dust-obscured star formation in these z˜ 2.5 galaxies on ˜1.3 kpc scales. The emission has a median effective radius of R e = 0.″24 ± 0.″02, corresponding to a typical physical size of {R}e= 1.8 ± 0.2 kpc. We derive a median Sérsic index of n = 0.9 ± 0.2, implying that the dust emission is remarkably disk-like at the current resolution and sensitivity. We use different weighting schemes with the visibilities to search for clumps on 0.″12 (˜1.0 kpc) scales, but we find no significant evidence for clumping in the majority of cases. Indeed, we demonstrate using simulations that the observed morphologies are generally consistent with smooth exponential disks, suggesting that caution should be exercised when identifying candidate clumps in even moderate signal-to-noise ratio interferometric data. We compare our maps to comparable-resolution Hubble Space Telescope {H}160-band images, finding that the stellar morphologies appear significantly more extended and disturbed, and suggesting that major mergers may be responsible for driving the formation of the compact dust disks we observe. The stark contrast between the obscured and unobscured morphologies may also have implications for SED fitting routines that assume the dust is co-located with the optical/near-IR continuum emission. Finally, we discuss the potential of the current bursts of star formation to transform the observed galaxy sizes and light profiles, showing that the z˜ 0 descendants of these SMGs are expected to have stellar masses, effective radii, and gas surface densities consistent with the most compact massive ({M}* ˜ 1-2 × 1011 {M}⊙ ) early-type galaxies observed locally.
Bashir, Mustafa R; Huang, Rong; Mayes, Nicholas; Marin, Daniele; Berg, Carl L; Nelson, Rendon C; Jaffe, Tracy A
2015-08-01
To determine the rate of agreement between the Organ Procurement and Transplant Network (OPTN) and Liver Imaging Reporting and Data System (LI-RADS) classifications for hypervascular liver nodules at least 1 cm in diameter, and for patient eligibility for hepatocellular/MELD (Model for Endstage Liver Disease) exception points. This retrospective study was approved by our Institutional Review Board and was compliant with the Health Insurance Portability and Accountability Act. The requirement for informed consent was waived. This study included 200 hypervascular hepatocellular nodules at least 1 cm in diameter on computed tomography (CT) or magnetic resonance imaging (MRI) examinations in 105 patients with chronic liver disease. Three radiologists blinded to clinical data independently evaluated nodule characteristics, including washout, capsule, size, and size on prior examination. Based on those characteristics, nodules were automatically classified as definite hepatocellular carcinoma (HCC) or not definite HCC using both the OPTN and LI-RADS classifications. Using these classifications and the Milan criteria, each examination was determined to be "below transplant criteria," "within transplant criteria," or "beyond transplant criteria." Agreement was assessed between readers and classification systems, using Fleiss' kappa, intraclass correlation coefficients (ICCs), and simple proportions. Interreader agreement was moderate for nodule features (κ = 0.59-0.69) and nodule classification (0.66-0.69). The two systems were in nearly complete agreement on nodule category assignment (98.7% [592/600]) and patient eligibility for transplant exemption priority (99.4% [313/315]). A few discrepancies occurred for the nodule feature of growth (1.3% [8/600]) and for nodule category assignment (1.3% [8/600]). Agreement between the OPTN and LI-RADS classifications is very strong for categorization of hypervascular liver nodules at least 1 cm in diameter, and for patient eligibility for hepatocellular/MELD exception points. Interreader variability is much higher than intersystem variability. © 2014 Wiley Periodicals, Inc.
Self-presentational persona: simultaneous management of multiple impressions.
Leary, Mark R; Allen, Ashley Batts
2011-11-01
Most research on self-presentation has examined how people convey images of themselves on only 1 or 2 dimensions at a time. In everyday interactions, however, people often manage their impressions on several image-relevant dimensions simultaneously. By examining people's self-presentations to several targets across multiple dimensions, these 2 studies offer new insights into the nature of self-presentation and provide a novel paradigm for studying impression management. Results showed that most people rely on a relatively small number of basic self-presentational personas in which they convey particular profiles of impressions as a set and that these personas reflect both normative influences to project images that are appropriate to a particular target and distinctive influences by which people put an idiosyncratic spin on these normative images. Furthermore, although people's self-presentational profiles correlate moderately with their self-views, they tailor their public images to specific targets. The degree to which participants' self-presentations were normative and distinctive, as well as the extent to which they reflected their own self-views, were moderated by individual differences in agreeableness, self-esteem, authenticity, and Machiavellianism.
Murakami, Yohko; Wang, Dandan; Burkemper, Bruce; Lin, Shan C.; Varma, Rohit
2016-01-01
Purpose To compare grading of goniophotographic images and gonioscopy in assessing the iridocorneal angle. Methods In a population-based, cross-sectional study, participants underwent gonioscopy and goniophotographic imaging during the same visit. The iridocorneal angle was classified as closed if the posterior trabecular meshwork could not be seen. A single masked observer graded the goniophotographic images, and each eye was classified as having angle closure based on the number of closed quadrants. Agreement between the methods was analyzed by calculating kappa (κ) and first-order agreement coefficient (AC1) statistics and comparison of area under receiver operating characteristic curves (AUC). Results A total of 4149 Chinese Americans (3994 eyes) were included in this study. The agreement for angle closure diagnosis between gonioscopy and EyeCam was moderate to excellent (κ = 0.60, AC1 0.90, AUC 0.76–0.80). Conclusions Detection of iridocorneal angle closure based on goniophotographic imaging shows moderate to very good agreement with angle closure assessment using gonioscopy. PMID:27571018
2009-10-01
Field-of-View, Mobile PET/SPECT System for Bedside Environments: A Dynamic Cardiac Phantom Study using 99mTc and 18F- FDG . Presented at the American...using Tc-99m tracers and viability imaging using F- 18 tracers [3]-[7]. For cardiac F-18 imaging in a bedside environment, the 511 keV SPECT approach...SPECT system may have difficulty imaging subtle myocardial defects with F-18 tracers , but it may effectively image moderate to severe defects. The
NASA Astrophysics Data System (ADS)
Lin, Shengtao; Zhang, Ge; Jamburidze, Akaki; Chee, Melisse; Hau Leow, Chee; Garbin, Valeria; Tang, Meng-Xing
2018-03-01
Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5-20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter < 200 nm) population without micron-sized outliers (>1 µm) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.
My 'Fat Girl Complex': a preliminary investigation of sexual health and body image in women of size.
Satinsky, Sonya; Dennis, Barbara; Reece, Michael; Sanders, Stephanie; Bardzell, Shaowen
2013-01-01
Women of size who inhabit non-normative bodies may have different experiences with body image and sexual health than women of average body size. In this exploratory study, we interviewed four women of size recruited from a larger mixed-methodological study of body image and sexuality. Each woman was interviewed twice on topics of body image, sexuality and sexual health. Reconstructive Horizon Analysis was used to analyse the content of the interviews. Women who expressed that their bodies had inherent personal and social value regardless of size did not articulate connections between body size and their sexual health. However, those women who looked externally for validation of their attractiveness struggled with acceptance of their sexuality and bodies and spoke of ways in which their body size and appearance hindered them from having the sexually healthy lives that they wanted. Findings highlight two important components of women's sexual health as participants related them to body image: the right to pleasure and the right to engage only in wanted sexual activity. Participants described how negative body attitudes affected both of these aspects of their sexual health. Interventions targeting weight-based stigma may offer a means of indirectly promoting sexual health and autonomy in women.
Ikuta, Ichiro; Warden, Graham I.; Andriole, Katherine P.; Khorasani, Ramin
2014-01-01
Purpose To test the hypothesis that patient size can be accurately calculated from axial computed tomographic (CT) images, including correction for the effects of anatomy truncation that occur in routine clinical CT image reconstruction. Materials and Methods Institutional review board approval was obtained for this HIPAA-compliant study, with waiver of informed consent. Water-equivalent diameter (DW) was computed from the attenuation-area product of each image within 50 adult CT scans of the thorax and of the abdomen and pelvis and was also measured for maximal field of view (FOV) reconstructions. Linear regression models were created to compare DW with the effective diameter (Deff) used to select size-specific volume CT dose index (CTDIvol) conversion factors as defined in report 204 of the American Association of Physicists in Medicine. Linear regression models relating reductions in measured DW to a metric of anatomy truncation were used to compensate for the effects of clinical image truncation. Results In the thorax, DW versus Deff had an R2 of 0.51 (n = 200, 50 patients at four anatomic locations); in the abdomen and pelvis, R2 was 0.90 (n = 150, 50 patients at three anatomic locations). By correcting for image truncation, the proportion of clinically reconstructed images with an extracted DW within ±5% of the maximal FOV DW increased from 54% to 90% in the thorax (n = 3602 images) and from 95% to 100% in the abdomen and pelvis (6181 images). Conclusion The DW extracted from axial CT images is a reliable measure of patient size, and varying degrees of clinical image truncation can be readily corrected. Automated measurement of patient size combined with CT radiation exposure metrics may enable patient-specific dose estimation on a large scale. © RSNA, 2013 PMID:24086075
Nyflot, Matthew J.; Yang, Fei; Byrd, Darrin; Bowen, Stephen R.; Sandison, George A.; Kinahan, Paul E.
2015-01-01
Abstract. Image heterogeneity metrics such as textural features are an active area of research for evaluating clinical outcomes with positron emission tomography (PET) imaging and other modalities. However, the effects of stochastic image acquisition noise on these metrics are poorly understood. We performed a simulation study by generating 50 statistically independent PET images of the NEMA IQ phantom with realistic noise and resolution properties. Heterogeneity metrics based on gray-level intensity histograms, co-occurrence matrices, neighborhood difference matrices, and zone size matrices were evaluated within regions of interest surrounding the lesions. The impact of stochastic variability was evaluated with percent difference from the mean of the 50 realizations, coefficient of variation and estimated sample size for clinical trials. Additionally, sensitivity studies were performed to simulate the effects of patient size and image reconstruction method on the quantitative performance of these metrics. Complex trends in variability were revealed as a function of textural feature, lesion size, patient size, and reconstruction parameters. In conclusion, the sensitivity of PET textural features to normal stochastic image variation and imaging parameters can be large and is feature-dependent. Standards are needed to ensure that prospective studies that incorporate textural features are properly designed to measure true effects that may impact clinical outcomes. PMID:26251842
Nyflot, Matthew J; Yang, Fei; Byrd, Darrin; Bowen, Stephen R; Sandison, George A; Kinahan, Paul E
2015-10-01
Image heterogeneity metrics such as textural features are an active area of research for evaluating clinical outcomes with positron emission tomography (PET) imaging and other modalities. However, the effects of stochastic image acquisition noise on these metrics are poorly understood. We performed a simulation study by generating 50 statistically independent PET images of the NEMA IQ phantom with realistic noise and resolution properties. Heterogeneity metrics based on gray-level intensity histograms, co-occurrence matrices, neighborhood difference matrices, and zone size matrices were evaluated within regions of interest surrounding the lesions. The impact of stochastic variability was evaluated with percent difference from the mean of the 50 realizations, coefficient of variation and estimated sample size for clinical trials. Additionally, sensitivity studies were performed to simulate the effects of patient size and image reconstruction method on the quantitative performance of these metrics. Complex trends in variability were revealed as a function of textural feature, lesion size, patient size, and reconstruction parameters. In conclusion, the sensitivity of PET textural features to normal stochastic image variation and imaging parameters can be large and is feature-dependent. Standards are needed to ensure that prospective studies that incorporate textural features are properly designed to measure true effects that may impact clinical outcomes.
Shaw, Leslee J.; Berman, Daniel S.; Picard, Michael H.; Friedrich, Matthias G.; Kwong, Raymond Y.; Stone, Gregg W.; Senior, Roxy; Min, James K.; Hachamovitch, Rory; Scherrer-Crosbie, Marielle; Mieres, Jennifer H.; Marwick, Thomas H.; Phillips, Lawrence M.; Chaudhry, Farooq A.; Pellikka, Patricia A.; Slomka, Piotr; Arai, Andrew E.; Iskandrian, Ami E.; Bateman, Timothy M.; Heller, Gary V.; Miller, Todd D.; Nagel, Eike; Goyal, Abhinav; Borges-Neto, Salvador; Boden, William E.; Reynolds, Harmony R.; Hochman, Judith S.; Maron, David J.; Douglas, Pamela S.
2014-01-01
The lack of standardized reporting of the magnitude of ischemia on noninvasive imaging contributes to variability in translating the severity of ischemia across stress imaging modalities. We identified the risk of coronary artery disease (CAD) death or myocardial infarction (MI) associated with ≥10% ischemic myocardium on stress nuclear imaging as the risk threshold for stress echocardiography and cardiac magnetic resonance. A narrative review revealed that ≥10% ischemic myocardium on stress nuclear imaging was associated with a median rate of CAD death or MI of 4.9%/year (interquartile range: 3.75% to 5.3%). For stress echocardiography, ≥3 newly dysfunctional segments portend a median rate of CAD death or MI of 4.5%/year (interquartile range: 3.8% to 5.9%). Although imprecisely delineated, moderate-severe ischemia on cardiac magnetic resonance may be indicated by ≥4 of 32 stress perfusion defects or ≥3 dobutamine-induced dysfunctional segments. Risk-based thresholds can define equivalent amounts of ischemia across the stress imaging modalities, which will help to translate a common understanding of patient risk on which to guide subsequent management decisions. PMID:24925328