1986-08-01
SECURITY CLASSIFICATION AUTHORITY 3 DISTRIBUTIONAVAILABILITY OF REPORT N/A \\pproved for public release, 21b. OECLASS FI) CAT ) ON/OOWNGRAOING SCMEOLLE...from this set of projections. The Convolution Back-Projection (CBP) algorithm is widely used technique in Computer Aide Tomography ( CAT ). In this work...University of Illinois at Urbana-Champaign. 1985 Ac % DTICEl_ FCTE " AUG 1 11986 Urbana. Illinois U,) I A NEW METHOD OF SYNTHETIC APERTURE RADAR IMAGE
NASA Astrophysics Data System (ADS)
Lu, Tong; Wang, Yihan; Gao, Feng; Zhao, Huijuan; Ntziachristos, Vasilis; Li, Jiao
2018-02-01
Photoacoustic mesoscopy (PAMe), offering high-resolution (sub-100-μm) and high optical contrast imaging at the depth of 1-10 mm, generally obtains massive collection data using a high-frequency focused ultrasonic transducer. The spatial impulse response (SIR) of this focused transducer causes the distortion of measured signals in both duration and amplitude. Thus, the reconstruction method considering the SIR needs to be investigated in the computation-economic way for PAMe. Here, we present a modified back-projection algorithm, by introducing a SIR-dependent calibration process using a non-satationary convolution method. The proposed method is performed on numerical simulations and phantom experiments of microspheres with diameter of both 50 μm and 100 μm, and the improvement of image fidelity of this method is proved to be evident by methodology parameters. The results demonstrate that, the images reconstructed when the SIR of transducer is accounted for have higher contrast-to-noise ratio and more reasonable spatial resolution, compared to the common back-projection algorithm.
Accelerating separable footprint (SF) forward and back projection on GPU
NASA Astrophysics Data System (ADS)
Xie, Xiaobin; McGaffin, Madison G.; Long, Yong; Fessler, Jeffrey A.; Wen, Minhua; Lin, James
2017-03-01
Statistical image reconstruction (SIR) methods for X-ray CT can improve image quality and reduce radiation dosages over conventional reconstruction methods, such as filtered back projection (FBP). However, SIR methods require much longer computation time. The separable footprint (SF) forward and back projection technique simplifies the calculation of intersecting volumes of image voxels and finite-size beams in a way that is both accurate and efficient for parallel implementation. We propose a new method to accelerate the SF forward and back projection on GPU with NVIDIA's CUDA environment. For the forward projection, we parallelize over all detector cells. For the back projection, we parallelize over all 3D image voxels. The simulation results show that the proposed method is faster than the acceleration method of the SF projectors proposed by Wu and Fessler.13 We further accelerate the proposed method using multiple GPUs. The results show that the computation time is reduced approximately proportional to the number of GPUs.
NASA Technical Reports Server (NTRS)
Lundberg, J. B.; Feulner, M. R.; Abusali, P. A. M.; Ho, C. S.
1991-01-01
The method of modified back differences, a technique that significantly reduces the numerical integration errors associated with crossing shadow boundaries using a fixed-mesh multistep integrator without a significant increase in computer run time, is presented. While Hubbard's integral approach can produce significant improvements to the trajectory solution, the interpolation method provides the best overall results. It is demonstrated that iterating on the point mass term correction is also important for achieving the best overall results. It is also shown that the method of modified back differences can be implemented with only a small increase in execution time.
Uncertainty Analyses for Back Projection Methods
NASA Astrophysics Data System (ADS)
Zeng, H.; Wei, S.; Wu, W.
2017-12-01
So far few comprehensive error analyses for back projection methods have been conducted, although it is evident that high frequency seismic waves can be easily affected by earthquake depth, focal mechanisms and the Earth's 3D structures. Here we perform 1D and 3D synthetic tests for two back projection methods, MUltiple SIgnal Classification (MUSIC) (Meng et al., 2011) and Compressive Sensing (CS) (Yao et al., 2011). We generate synthetics for both point sources and finite rupture sources with different depths, focal mechanisms, as well as 1D and 3D structures in the source region. The 3D synthetics are generated through a hybrid scheme of Direct Solution Method and Spectral Element Method. Then we back project the synthetic data using MUSIC and CS. The synthetic tests show that the depth phases can be back projected as artificial sources both in space and time. For instance, for a source depth of 10km, back projection gives a strong signal 8km away from the true source. Such bias increases with depth, e.g., the error of horizontal location could be larger than 20km for a depth of 40km. If the array is located around the nodal direction of direct P-waves the teleseismic P-waves are dominated by the depth phases. Therefore, back projections are actually imaging the reflection points of depth phases more than the rupture front. Besides depth phases, the strong and long lasted coda waves due to 3D effects near trench can lead to additional complexities tested here. The strength contrast of different frequency contents in the rupture models also produces some variations to the back projection results. In the synthetic tests, MUSIC and CS derive consistent results. While MUSIC is more computationally efficient, CS works better for sparse arrays. In summary, our analyses indicate that the impact of various factors mentioned above should be taken into consideration when interpreting back projection images, before we can use them to infer the earthquake rupture physics.
Modified Hawking Radiation from a Kerr-Newman Black Hole due to Back-Reaction
NASA Astrophysics Data System (ADS)
Liu, Bo; Wang, Gang; Liu, Wenbiao
Hawking radiation from a general Kerr-Newman black hole is investigated using Damour-Ruffini's method. Considering the back-reaction of particle's energy, charge and angular momentum to the spacetime, we obtain a modified nonthermal spectrum. Maybe the information loss paradox can be explained, furthermore, the result is also consistent with the result obtained using Parikh and Wilczek's method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ain, Khusnul; Physics Department - Airlangga University, Surabaya – Indonesia, khusnulainunair@yahoo.com; Kurniadi, Deddy
2015-04-16
Back projection reconstruction has been implemented to get the dynamical image in electrical impedance tomography. However the implementation is still limited in method of adjacent data collection and circular object element model. The study aims to develop the methods of back projection as reconstruction method that has the high speed, accuracy, and flexibility, which can be used for various methods of data collection and model of the object element. The proposed method uses the forward problem solution as the operator of filtered and back projection matrix. This is done through a simulation study on several methods of data collection andmore » various models of the object element. The results indicate that the developed method is capable of producing images, fastly and accurately for reconstruction of the various methods of data collection and models of the object element.« less
Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate
NASA Astrophysics Data System (ADS)
Bedford, James L.; Hanson, Ian M.; Hansen, Vibeke N.
2018-01-01
In the forward-projection method of portal dosimetry for volumetric modulated arc therapy (VMAT), the integrated signal at the electronic portal imaging device (EPID) is predicted at the time of treatment planning, against which the measured integrated image is compared. In the back-projection method, the measured signal at each gantry angle is back-projected through the patient CT scan to give a measure of total dose to the patient. This study aims to investigate the practical agreement between the two types of EPID dosimetry for prostate radiotherapy. The AutoBeam treatment planning system produced VMAT plans together with corresponding predicted portal images, and a total of 46 sets of gantry-resolved portal images were acquired in 13 patients using an iViewGT portal imager. For the forward-projection method, each acquisition of gantry-resolved images was combined into a single integrated image and compared with the predicted image. For the back-projection method, iViewDose was used to calculate the dose distribution in the patient for comparison with the planned dose. A gamma index for 3% and 3 mm was used for both methods. The results were investigated by delivering the same plans to a phantom and repeating some of the deliveries with deliberately introduced errors. The strongest agreement between forward- and back-projection methods is seen in the isocentric intensity/dose difference, with moderate agreement in the mean gamma. The strongest correlation is observed within a given patient, with less correlation between patients, the latter representing the accuracy of prediction of the two methods. The error study shows that each of the two methods has its own distinct sensitivity to errors, but that overall the response is similar. The forward- and back-projection EPID dosimetry methods show moderate agreement in this series of prostate VMAT patients, indicating that both methods can contribute to the verification of dose delivered to the patient.
NASA Astrophysics Data System (ADS)
Yuniarto, Budi; Kurniawan, Robert
2017-03-01
PLS Path Modeling (PLS-PM) is different from covariance based SEM, where PLS-PM use an approach based on variance or component, therefore, PLS-PM is also known as a component based SEM. Multiblock Partial Least Squares (MBPLS) is a method in PLS regression which can be used in PLS Path Modeling which known as Multiblock PLS Path Modeling (MBPLS-PM). This method uses an iterative procedure in its algorithm. This research aims to modify MBPLS-PM with Back Propagation Neural Network approach. The result is MBPLS-PM algorithm can be modified using the Back Propagation Neural Network approach to replace the iterative process in backward and forward step to get the matrix t and the matrix u in the algorithm. By modifying the MBPLS-PM algorithm using Back Propagation Neural Network approach, the model parameters obtained are relatively not significantly different compared to model parameters obtained by original MBPLS-PM algorithm.
Camera calibration based on the back projection process
NASA Astrophysics Data System (ADS)
Gu, Feifei; Zhao, Hong; Ma, Yueyang; Bu, Penghui
2015-12-01
Camera calibration plays a crucial role in 3D measurement tasks of machine vision. In typical calibration processes, camera parameters are iteratively optimized in the forward imaging process (FIP). However, the results can only guarantee the minimum of 2D projection errors on the image plane, but not the minimum of 3D reconstruction errors. In this paper, we propose a universal method for camera calibration, which uses the back projection process (BPP). In our method, a forward projection model is used to obtain initial intrinsic and extrinsic parameters with a popular planar checkerboard pattern. Then, the extracted image points are projected back into 3D space and compared with the ideal point coordinates. Finally, the estimation of the camera parameters is refined by a non-linear function minimization process. The proposed method can obtain a more accurate calibration result, which is more physically useful. Simulation and practical data are given to demonstrate the accuracy of the proposed method.
Robertson, David; Kumbhare, Dinesh; Nolet, Paul; Srbely, John; Newton, Genevieve
2017-01-01
Introduction The association between depression, somatization and low back pain has been minimally investigated in a Canadian emerging adult population. Methods 1013 first year Canadian university students completed the Modified Zung Depression Index, the Modified Somatic Perception Questionnaire, and a survey about low back pain frequency and intensity. Multinomial logistic regression was used to measure associations between low back pain and depression and somatization, both independently and co-occurring. Results Over 50% of subjects reported low back pain across grades, and both depression and somatization were significantly positively associated with low back pain. Several positive associations between the cooccurrence of somatization and depression with various grades of low back pain were observed. Discussion These results suggest that low back pain, depression and somatization are relatively common at the onset of adulthood, and should be considered an important focus of public health. PMID:28928493
NASA Astrophysics Data System (ADS)
Xie, Lizhe; Hu, Yining; Chen, Yang; Shi, Luyao
2015-03-01
Projection and back-projection are the most computational consuming parts in Computed Tomography (CT) reconstruction. Parallelization strategies using GPU computing techniques have been introduced. We in this paper present a new parallelization scheme for both projection and back-projection. The proposed method is based on CUDA technology carried out by NVIDIA Corporation. Instead of build complex model, we aimed on optimizing the existing algorithm and make it suitable for CUDA implementation so as to gain fast computation speed. Besides making use of texture fetching operation which helps gain faster interpolation speed, we fixed sampling numbers in the computation of projection, to ensure the synchronization of blocks and threads, thus prevents the latency caused by inconsistent computation complexity. Experiment results have proven the computational efficiency and imaging quality of the proposed method.
Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.
Wu, Meng; Keil, Andreas; Constantin, Dragos; Star-Lack, Josh; Zhu, Lei; Fahrig, Rebecca
2014-12-01
The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10-15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%-10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.
NASA Astrophysics Data System (ADS)
Tan, F.; Wang, G.; Chen, C.; Ge, Z.
2016-12-01
Back-projection of teleseismic P waves [Ishii et al., 2005] has been widely used to image the rupture of earthquakes. Besides the conventional narrowband beamforming in time domain, approaches in frequency domain such as MUSIC back projection (Meng 2011) and compressive sensing (Yao et al, 2011), are proposed to improve the resolution. Each method has its advantages and disadvantages and should be properly used in different cases. Therefore, a thorough research to compare and test these methods is needed. We write a GUI program, which puts the three methods together so that people can conveniently use different methods to process the same data and compare the results. Then we use all the methods to process several earthquake data, including 2008 Wenchuan Mw7.9 earthquake and 2011 Tohoku-Oki Mw9.0 earthquake, and theoretical seismograms of both simple sources and complex ruptures. Our results show differences in efficiency, accuracy and stability among the methods. Quantitative and qualitative analysis are applied to measure their dependence on data and parameters, such as station number, station distribution, grid size, calculate window length and so on. In general, back projection makes it possible to get a good result in a very short time using less than 20 lines of high-quality data with proper station distribution, but the swimming artifact can be significant. Some ways, for instance, combining global seismic data, could help ameliorate this method. Music back projection needs relatively more data to obtain a better and more stable result, which means it needs a lot more time since its runtime accumulates obviously faster than back projection with the increase of station number. Compressive sensing deals more effectively with multiple sources in a same time window, however, costs the longest time due to repeatedly solving matrix. Resolution of all the methods is complicated and depends on many factors. An important one is the grid size, which in turn influences runtime significantly. More detailed results in this research may help people to choose proper data, method and parameters.
Filtered back-projection algorithm for Compton telescopes
Gunter, Donald L [Lisle, IL
2008-03-18
A method for the conversion of Compton camera data into a 2D image of the incident-radiation flux on the celestial sphere includes detecting coincident gamma radiation flux arriving from various directions of a 2-sphere. These events are mapped by back-projection onto the 2-sphere to produce a convolution integral that is subsequently stereographically projected onto a 2-plane to produce a second convolution integral which is deconvolved by the Fourier method to produce an image that is then projected onto the 2-sphere.
NASA Astrophysics Data System (ADS)
Beskardes, G. D.; Hole, J. A.; Wang, K.; Wu, Q.; Chapman, M. C.; Davenport, K. K.; Michaelides, M.; Brown, L. D.; Quiros, D. A.
2016-12-01
Back-projection imaging has recently become a practical method for local earthquake detection and location due to the deployment of densely sampled, continuously recorded, local seismograph arrays. Back-projection is scalable to earthquakes with a wide range of magnitudes from very tiny to very large. Local dense arrays provide the opportunity to capture very tiny events for a range applications, such as tectonic microseismicity, source scaling studies, wastewater injection-induced seismicity, hydraulic fracturing, CO2 injection monitoring, volcano studies, and mining safety. While back-projection sometimes utilizes the full seismic waveform, the waveforms are often pre-processed to overcome imaging issues. We compare the performance of back-projection using four previously used data pre-processing methods: full waveform, envelope, short-term averaging / long-term averaging (STA/LTA), and kurtosis. The goal is to identify an optimized strategy for an entirely automated imaging process that is robust in the presence of real-data issues, has the lowest signal-to-noise thresholds for detection and for location, has the best spatial resolution of the energy imaged at the source, preserves magnitude information, and considers computational cost. Real data issues include aliased station spacing, low signal-to-noise ratio (to <1), large noise bursts and spatially varying waveform polarity. For evaluation, the four imaging methods were applied to the aftershock sequence of the 2011 Virginia earthquake as recorded by the AIDA array with 200-400 m station spacing. These data include earthquake magnitudes from -2 to 3 with highly variable signal to noise, spatially aliased noise, and large noise bursts: realistic issues in many environments. Each of the four back-projection methods has advantages and disadvantages, and a combined multi-pass method achieves the best of all criteria. Preliminary imaging results from the 2011 Virginia dataset will be presented.
78 FR 13402 - Proposed Collection; Comment Request for Regulation Project
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-27
... the election not to apply look-back method in de minimis cases. DATES: Written comments should be... . SUPPLEMENTARY INFORMATION: Title: Election Not to Apply Look-Back Method in De Minimis Cases. OMB Number: 1545...), a taxpayer may elect not to apply the look-back method to long-term contracts in de minimis cases...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez Reyes, B; Rodriguez Perez, E; Sosa Aquino, M
Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results:more » A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.« less
Metal artifact correction for x-ray computed tomography using kV and selective MV imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Meng, E-mail: mengwu@stanford.edu; Keil, Andreas; Constantin, Dragos
Purpose: The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Methods: Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kVmore » and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. Results: The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10–15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%–10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. Conclusions: The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.« less
Use of the Hotelling observer to optimize image reconstruction in digital breast tomosynthesis
Sánchez, Adrian A.; Sidky, Emil Y.; Pan, Xiaochuan
2015-01-01
Abstract. We propose an implementation of the Hotelling observer that can be applied to the optimization of linear image reconstruction algorithms in digital breast tomosynthesis. The method is based on considering information within a specific region of interest, and it is applied to the optimization of algorithms for detectability of microcalcifications. Several linear algorithms are considered: simple back-projection, filtered back-projection, back-projection filtration, and Λ-tomography. The optimized algorithms are then evaluated through the reconstruction of phantom data. The method appears robust across algorithms and parameters and leads to the generation of algorithm implementations which subjectively appear optimized for the task of interest. PMID:26702408
Wong, Ngai Sze; Wong, Ka Hing; Lee, Man Po; Tsang, Owen T Y; Chan, Denise P C; Lee, Shui Shan
2016-01-01
Undiagnosed infections accounted for the hidden proportion of HIV cases that have escaped from public health surveillance. To assess the population risk of HIV transmission, we estimated the undiagnosed interval of each known infection for constructing the HIV incidence curves. We used modified back-calculation methods to estimate the seroconversion year for each diagnosed patient attending any one of the 3 HIV specialist clinics in Hong Kong. Three approaches were used, depending on the adequacy of CD4 data: (A) estimating one's pre-treatment CD4 depletion rate in multilevel model;(B) projecting one's seroconversion year by referencing seroconverters' CD4 depletion rate; or (C) projecting from the distribution of estimated undiagnosed intervals in (B). Factors associated with long undiagnosed interval (>2 years) were examined in univariate analyses. Epidemic curves constructed from estimated seroconversion data were evaluated by modes of transmission. Between 1991 and 2010, a total of 3695 adult HIV patients were diagnosed. The undiagnosed intervals were derived from method (A) (28%), (B) (61%) and (C) (11%) respectively. The intervals ranged from 0 to 10 years, and were shortened from 2001. Heterosexual infection, female, Chinese and age >64 at diagnosis were associated with long undiagnosed interval. Overall, the peaks of the new incidence curves were reached 4-6 years ahead of reported diagnoses, while their contours varied by mode of transmission. Characteristically, the epidemic growth of heterosexual male and female declined after 1998 with slight rebound in 2004-2006, but that of MSM continued to rise after 1998. By determining the time of seroconversion, HIV epidemic curves could be reconstructed from clinical data to better illustrate the trends of new infections. With the increasing coverage of antiretroviral therapy, the undiagnosed interval can add to the measures for assessing HIV transmission risk in the population.
Three-dimensional Image Reconstruction in J-PET Using Filtered Back-projection Method
NASA Astrophysics Data System (ADS)
Shopa, R. Y.; Klimaszewski, K.; Kowalski, P.; Krzemień, W.; Raczyński, L.; Wiślicki, W.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
Research on Synthetic Aperture Radar Processing for the Spaceborne Sliding Spotlight Mode.
Shen, Shijian; Nie, Xin; Zhang, Xinggan
2018-02-03
Gaofen-3 (GF-3) is China' first C-band multi-polarization synthetic aperture radar (SAR) satellite, which also provides the sliding spotlight mode for the first time. Sliding-spotlight mode is a novel mode to realize imaging with not only high resolution, but also wide swath. Several key technologies for sliding spotlight mode in spaceborne SAR with high resolution are investigated in this paper, mainly including the imaging parameters, the methods of velocity estimation and ambiguity elimination, and the imaging algorithms. Based on the chosen Convolution BackProjection (CBP) and PFA (Polar Format Algorithm) imaging algorithms, a fast implementation method of CBP and a modified PFA method suitable for sliding spotlight mode are proposed, and the processing flows are derived in detail. Finally, the algorithms are validated by simulations and measured data.
NASA Astrophysics Data System (ADS)
Li, Miao; Li, Xiao-Dong; Wang, Shuang; Wang, Yi
2013-12-01
The problem of dark energy is briefly reviewed in both theoretical and observational aspects. In the theoretical aspect, dark energy scenarios are classified into symmetry, anthropic principle, tuning mechanism, modified gravity, quantum cosmology, holographic principle, back-reaction and phenomenological types. In the observational aspect, we introduce cosmic probes, dark energy related projects, observational constraints on theoretical models and model independent reconstructions.
Navigating Earthquake Physics with High-Resolution Array Back-Projection
NASA Astrophysics Data System (ADS)
Meng, Lingsen
Understanding earthquake source dynamics is a fundamental goal of geophysics. Progress toward this goal has been slow due to the gap between state-of-art earthquake simulations and the limited source imaging techniques based on conventional low-frequency finite fault inversions. Seismic array processing is an alternative source imaging technique that employs the higher frequency content of the earthquakes and provides finer detail of the source process with few prior assumptions. While the back-projection provides key observations of previous large earthquakes, the standard beamforming back-projection suffers from low resolution and severe artifacts. This thesis introduces the MUSIC technique, a high-resolution array processing method that aims to narrow the gap between the seismic observations and earthquake simulations. The MUSIC is a high-resolution method taking advantage of the higher order signal statistics. The method has not been widely used in seismology yet because of the nonstationary and incoherent nature of the seismic signal. We adapt MUSIC to transient seismic signal by incorporating the Multitaper cross-spectrum estimates. We also adopt a "reference window" strategy that mitigates the "swimming artifact," a systematic drift effect in back projection. The improved MUSIC back projections allow the imaging of recent large earthquakes in finer details which give rise to new perspectives on dynamic simulations. In the 2011 Tohoku-Oki earthquake, we observe frequency-dependent rupture behaviors which relate to the material variation along the dip of the subduction interface. In the 2012 off-Sumatra earthquake, we image the complicated ruptures involving orthogonal fault system and an usual branching direction. This result along with our complementary dynamic simulations probes the pressure-insensitive strength of the deep oceanic lithosphere. In another example, back projection is applied to the 2010 M7 Haiti earthquake recorded at regional distance. The high-frequency subevents are located at the edges of geodetic slip regions, which are correlated to the stopping phases associated with rupture speed reduction when the earthquake arrests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pelliccia, Daniele; Vaz, Raquel; Svalbe, Imants
X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve themore » same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.« less
1981-04-28
After completing it's first orbital mission with a landing at Edwards Air Force Base on April 14, 1981, Space Shuttle Columbia received a humorous sendoff before it's ferry flight atop a modified 747 back to the Kennedy Space Center in Florida. Holding the sign are, left to right: Melvin Burke, DFRC Orbital Flight Test (OFT) Program Manager; Isaac 'Ike' Gillam, DFRC Center Director; Fitzhugh 'Fitz' L. Fulton Jr., NASA DFRC 747 SCA Pilot; and Donald K. 'Deke' Slayton, JSC OFT Project Manager.
Dekkers, A L M; Slob, W
2012-10-01
In dietary exposure assessment, statistical methods exist for estimating the usual intake distribution from daily intake data. These methods transform the dietary intake data to normal observations, eliminate the within-person variance, and then back-transform the data to the original scale. We propose Gaussian Quadrature (GQ), a numerical integration method, as an efficient way of back-transformation. We compare GQ with six published methods. One method uses a log-transformation, while the other methods, including GQ, use a Box-Cox transformation. This study shows that, for various parameter choices, the methods with a Box-Cox transformation estimate the theoretical usual intake distributions quite well, although one method, a Taylor approximation, is less accurate. Two applications--on folate intake and fruit consumption--confirmed these results. In one extreme case, some methods, including GQ, could not be applied for low percentiles. We solved this problem by modifying GQ. One method is based on the assumption that the daily intakes are log-normally distributed. Even if this condition is not fulfilled, the log-transformation performs well as long as the within-individual variance is small compared to the mean. We conclude that the modified GQ is an efficient, fast and accurate method for estimating the usual intake distribution. Copyright © 2012 Elsevier Ltd. All rights reserved.
75 FR 5852 - Proposed Collection; Comment Request for Regulation Project
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-04
... Method in De Minimis Cases (Sec. 1.460-6). DATES: Written comments should be received on or before April... INFORMATION: Title: Election Not to Apply Look-Back Method in De Minimis Cases. OMB Number: 1545-1572... may elect not to apply the look-back method to long-term contracts in de minimis cases. The taxpayer...
Roelofs, Jeffrey; Peters, Madelon L; Vlaeyen, Johan W S
2003-06-01
The present study assessed, by means of a modified Stroop paradigm, whether highly fearful patients with chronic low back pain pay selective attention to words related to movement and injury. Two groups of patients (High Fear and Low Fear) were included based on their scores on the Tampa Scale of Kinesiophobia (TSK), a measure of fear of movement or (re)injury. A control group was recruited by means of advertisement in a local newspaper. Repeated-measures analysis of variance was conducted to examine whether highly fearful pain patients pay more selective attention to movement and injury words, compared to patients with low pain-related fear and controls. The results from the present study do not support the proposition that highly fearful patients with chronic low back pain selectively pay attention to words related to injury and movement. Limitations of the modified Stroop paradigm are discussed as well as the need for the application of alternative methods such as the dot-probe paradigm.
EUVL back-insertion layout optimization
NASA Astrophysics Data System (ADS)
Civay, D.; Laffosse, E.; Chesneau, A.
2018-03-01
Extreme ultraviolet lithography (EUVL) is targeted for front-up insertion at advanced technology nodes but will be evaluated for back insertion at more mature nodes. EUVL can put two or more mask levels back on one mask, depending upon what level(s) in the process insertion occurs. In this paper, layout optimization methods are discussed that can be implemented when EUVL back insertion is implemented. The layout optimizations can be focused on improving yield, reliability or density, depending upon the design needs. The proposed methodology modifies the original two or more colored layers and generates an optimized single color EUVL layout design.
Feature selection and back-projection algorithms for nonline-of-sight laser-gated viewing
NASA Astrophysics Data System (ADS)
Laurenzis, Martin; Velten, Andreas
2014-11-01
We discuss new approaches to analyze laser-gated viewing data for nonline-of-sight vision with a frame-to-frame back-projection as well as feature selection algorithms. Although first back-projection approaches use time transients for each pixel, our method has the ability to calculate the projection of imaging data on the voxel space for each frame. Further, different data analysis algorithms and their sequential application were studied with the aim of identifying and selecting signals from different target positions. A slight modification of commonly used filters leads to a powerful selection of local maximum values. It is demonstrated that the choice of the filter has an impact on the selectivity i.e., multiple target detection as well as on the localization precision.
NASA Astrophysics Data System (ADS)
Meng, Lingsen; Ampuero, Jean-Paul; Luo, Yingdi; Wu, Wenbo; Ni, Sidao
2012-12-01
Comparing teleseismic array back-projection source images of the 2011 Tohoku-Oki earthquake with results from static and kinematic finite source inversions has revealed little overlap between the regions of high- and low-frequency slip. Motivated by this interesting observation, back-projection studies extended to intermediate frequencies, down to about 0.1 Hz, have suggested that a progressive transition of rupture properties as a function of frequency is observable. Here, by adapting the concept of array response function to non-stationary signals, we demonstrate that the "swimming artifact", a systematic drift resulting from signal non-stationarity, induces significant bias on beamforming back-projection at low frequencies. We introduce a "reference window strategy" into the multitaper-MUSIC back-projection technique and significantly mitigate the "swimming artifact" at high frequencies (1 s to 4 s). At lower frequencies, this modification yields notable, but significantly smaller, artifacts than time-domain stacking. We perform extensive synthetic tests that include a 3D regional velocity model for Japan. We analyze the recordings of the Tohoku-Oki earthquake at the USArray and at the European array at periods from 1 s to 16 s. The migration of the source location as a function of period, regardless of the back-projection methods, has characteristics that are consistent with the expected effect of the "swimming artifact". In particular, the apparent up-dip migration as a function of frequency obtained with the USArray can be explained by the "swimming artifact". This indicates that the most substantial frequency-dependence of the Tohoku-Oki earthquake source occurs at periods longer than 16 s. Thus, low-frequency back-projection needs to be further tested and validated in order to contribute to the characterization of frequency-dependent rupture properties.
NASA Astrophysics Data System (ADS)
Duc-Toan, Nguyen; Tien-Long, Banh; Young-Suk, Kim; Dong-Won, Jung
2011-08-01
In this study, a modified Johnson-Cook (J-C) model and an innovated method to determine (J-C) material parameters are proposed to predict more correctly stress-strain curve for tensile tests in elevated temperatures. A MATLAB tool is used to determine material parameters by fitting a curve to follow Ludwick's hardening law at various elevated temperatures. Those hardening law parameters are then utilized to determine modified (J-C) model material parameters. The modified (J-C) model shows the better prediction compared to the conventional one. As the first verification, an FEM tensile test simulation based on the isotropic hardening model for boron sheet steel at elevated temperatures was carried out via a user-material subroutine, using an explicit finite element code, and compared with the measurements. The temperature decrease of all elements due to the air cooling process was then calculated when considering the modified (J-C) model and coded to VUMAT subroutine for tensile test simulation of cooling process. The modified (J-C) model showed the good agreement between the simulation results and the corresponding experiments. The second investigation was applied for V-bending spring-back prediction of magnesium alloy sheets at elevated temperatures. Here, the combination of proposed J-C model with modified hardening law considering the unusual plastic behaviour for magnesium alloy sheet was adopted for FEM simulation of V-bending spring-back prediction and shown the good comparability with corresponding experiments.
An R-peak detection method that uses an SVD filter and a search back system.
Jung, Woo-Hyuk; Lee, Sang-Goog
2012-12-01
In this paper, we present a method for detecting the R-peak of an ECG signal by using an singular value decomposition (SVD) filter and a search back system. The ECG signal was detected in two phases: the pre-processing phase and the decision phase. The pre-processing phase consisted of the stages for the SVD filter, Butterworth High Pass Filter (HPF), moving average (MA), and squaring, whereas the decision phase consisted of a single stage that detected the R-peak. In the pre-processing phase, the SVD filter removed noise while the Butterworth HPF eliminated baseline wander. The MA removed the remaining noise of the signal that had gone through the SVD filter to make the signal smooth, and squaring played a role in strengthening the signal. In the decision phase, the threshold was used to set the interval before detecting the R-peak. When the latest R-R interval (RRI), suggested by Hamilton et al., was greater than 150% of the previous RRI, the method of detecting the R-peak in such an interval was modified to be 150% or greater than the smallest interval of the two most latest RRIs. When the modified search back system was used, the error rate of the peak detection decreased to 0.29%, compared to 1.34% when the modified search back system was not used. Consequently, the sensitivity was 99.47%, the positive predictivity was 99.47%, and the detection error was 1.05%. Furthermore, the quality of the signal in data with a substantial amount of noise was improved, and thus, the R-peak was detected effectively. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Laurenzis, Martin; Velten, Andreas
2014-10-01
In the present paper, we discuss new approaches to analyze laser gated viewing data for non-line-of-sight vision with a novel frame-to-frame back projection as well as feature selection algorithms. While first back projection approaches use time transients for each pixel, our new method has the ability to calculate the projection of imaging data on the obscured voxel space for each frame. Further, four different data analysis algorithms were studied with the aim to identify and select signals from different target positions. A slight modification of commonly used filters leads to powerful selection of local maximum values. It is demonstrated that the choice of the filter has impact on the selectivity i.e. multiple target detection as well as on the localization precision.
Berezovsky, Alexander Bogdanov; Pagkalos, Vasileios A; Shoham, Yaron; Krieger, Yuval; Silberstein, Eldad
2015-08-01
Breast reconstruction has become standard of care for female patients with breast cancer. The transverse rectus abdominis musculo-cutaneous flap (TRAMf) is the most common method of immediate or delayed autologous breast reconstruction following mastectomy. We share our experience with modified, double back cut of post-mastectomy skin in delayed pedicled TRAMf breast reconstruction, resulting in fish-shaped skin paddle. This sort of back cut is a simple, reliable way to obtain a natural, esthetically pleasant breast mound with inconspicuous hidden scars.
NASA Astrophysics Data System (ADS)
Park, J. H.; Chi, H. C.; Lim, I. S.; Seong, Y. J.; Pak, J.
2017-12-01
During the first phase of EEW(Earthquake Early Warning) service to the public by KMA (Korea Meteorological Administration) from 2015 in Korea, KIGAM(Korea Institute of Geoscience and Mineral Resources) has adopted ElarmS2 of UC Berkeley BSL and modified local magnitude relation, travel time curves and association procedures so called TrigDB back-filling method. The TrigDB back-filling method uses a database of sorted lists of stations based on epicentral distances of the pre-defined events located on the grids for 1,401 × 1,601 = 2,243,001 events around the Korean Peninsula at a grid spacing of 0.05 degrees. When the version of an event is updated, the TrigDB back-filling method is invoked. First, the grid closest to the epicenter of an event is chosen from the database and candidate stations, which are stations corresponding to the chosen grid and also adjacent to the already-associated stations, are selected. Second, the directions from the chosen grid to the associated stations are averaged to represent the direction of wave propagation, which is used as a reference for computing apparent travel times. The apparent travel times for the associated stations are computed using a P wave velocity of 5.5 km/s from the grid to the projected points in the reference direction. The travel times for the triggered candidate stations are also computed and used to obtain the difference between the apparent travel times of the associated stations and the triggered candidates. Finally, if the difference in the apparent travel times is less than that of the arrival times, the method forces the triggered candidate station to be associated with the event and updates the event location. This method is useful to reduce false locations of events which could be generated from the deep (> 500 km) and regional distance earthquakes happening on the subduction pacific plate boundaries. In comparison of the case study between TrigDB back-filling applied system and the others, we could get the more reliable results in the early stagy of the version updating by forced association of the neighbored stations.
Enhancing the pictorial content of digital holograms at 100 frames per second.
Tsang, P W M; Poon, T-C; Cheung, K W K
2012-06-18
We report a low complexity, non-iterative method for enhancing the sharpness, brightness, and contrast of the pictorial content that is recorded in a digital hologram, without the need of re-generating the latter from the original object scene. In our proposed method, the hologram is first back-projected to a 2-D virtual diffraction plane (VDP) which is located at close proximity to the original object points. Next the field distribution on the VDP, which shares similar optical properties as the object scene, is enhanced. Subsequently, the processed VDP is expanded into a full hologram. We demonstrate two types of enhancement: a modified histogram equalization to improve the brightness and contrast, and localized high-boost-filtering (LHBF) to increase the sharpness. Experiment results have demonstrated that our proposed method is capable of enhancing a 2048x2048 hologram at a rate of around 100 frames per second. To the best of our knowledge, this is the first time real-time image enhancement is considered in the context of digital holography.
Carbon Back Sputter Modeling for Hall Thruster Testing
NASA Technical Reports Server (NTRS)
Gilland, James H.; Williams, George J.; Burt, Jonathan M.; Yim, John Tamin
2016-01-01
Lifetime requirements for electric propulsion devices, including Hall Effect thrusters, are continually increasing, driven in part by NASA's inclusion of this technology in it's exploration architecture. NASA will demonstrate high-power electric propulsion system on the Solar Electric Propulsion Technology Demonstration Mission (SEP TDM). The Asteroid Redirect Robotic mission is one candidate SEP TDM, which is projected to require tens of thousands of thruster life. As thruster life is increased, for example through the use of improved magnetic field designs, the relative influence of facility effects increases. One such effect is the sputtering and redeposition, or back sputter, of facility materials by the high energy thruster plumes. In support of wear testing for the Hall Effect Rocket with Magnetic Shielding (HERMeS) project, the back sputter from a Hall effect thruster plume has been modeled for the NASA Glenn Research Center's Vacuum Facility 5. The predicted wear at a near-worst case condition of 600 V, 12.5 kW was found to be on the order of 1 micron/kh in a fully carbon-lined chamber. A more detailed numerical Monte Carlo code was also modified to estimate back sputter for a detailed facility and pumping configuration. This code demonstrated similar back sputter rate distributions, but is not yet accurately modeling the magnitudes. The modeling has been benchmarked to recent HERMeS wear testing, using multiple microbalance measurements. These recent measurements have yielded values on the order of 1.5 - 2 micron/kh at 600 V and 12.5 kW.
Lee, Natalie; Thompson, Nicolas R; Passek, Sandra; Stilphen, Mary; Katzan, Irene L
2017-11-01
The Activity Measure for Post-Acute Care (AM-PAC) is a generic metric of patient-reported functional status. The minimal clinically important difference (MCID) in the AM-PAC score has not been determined. The study objective was to determine the MCID for AM-PAC in people with low back pain. This was a retrospective cohort study. Anchor-based and distribution-based methods were used to estimate the MCID. The Modified Low Back Pain Disability Questionnaire was used as the anchor. Adults who had a primary ICD-9 code for low back pain in at least 1 outpatient physical therapist visit during an episode of care and who completed both the AM-PAC and the Modified Low Back Pain Disability Questionnaire in at least 2 visits during the care episode were included. The MCID was calculated for the AM-PAC basic mobility version as well its adapted version, which the Cleveland Clinic uses for patients 65 years old or older. A total of 1,271 participants were eligible for study. For the AM-PAC basic mobility version, anchor-based methods yielded MCID estimates of between 3.4 and 5.1, whereas distribution-based methods yielded estimates of 1.7 to 4.2. The minimal detectable change (MDC) for the AM-PAC basic mobility version was 3.3. For the adapted AM-PAC basic mobility version, the MCID was estimated to be between 2.9 and 4.0 via anchor-based methods and between 1.2 to 3.5 via distribution-based methods. The MDC for the adapted AM-PAC basic mobility version was 3.5. The estimated MCID was designed for people with low back pain only. The MCID ranged from 3.3 to 5.1 for the AM-PAC basic mobility version and 3.5 to 4 for the adapted version, with the MDC as the lower limit. Changes in the AM-PAC for people with low back pain may be interpreted using the estimated MCID. Future studies are needed to determine the AM-PAC MCID for populations other than those with low back pain. © 2017 American Physical Therapy Association
Objective evaluation of linear and nonlinear tomosynthetic reconstruction algorithms
NASA Astrophysics Data System (ADS)
Webber, Richard L.; Hemler, Paul F.; Lavery, John E.
2000-04-01
This investigation objectively tests five different tomosynthetic reconstruction methods involving three different digital sensors, each used in a different radiologic application: chest, breast, and pelvis, respectively. The common task was to simulate a specific representative projection for each application by summation of appropriately shifted tomosynthetically generated slices produced by using the five algorithms. These algorithms were, respectively, (1) conventional back projection, (2) iteratively deconvoluted back projection, (3) a nonlinear algorithm similar to back projection, except that the minimum value from all of the component projections for each pixel is computed instead of the average value, (4) a similar algorithm wherein the maximum value was computed instead of the minimum value, and (5) the same type of algorithm except that the median value was computed. Using these five algorithms, we obtained data from each sensor-tissue combination, yielding three factorially distributed series of contiguous tomosynthetic slices. The respective slice stacks then were aligned orthogonally and averaged to yield an approximation of a single orthogonal projection radiograph of the complete (unsliced) tissue thickness. Resulting images were histogram equalized, and actual projection control images were subtracted from their tomosynthetically synthesized counterparts. Standard deviations of the resulting histograms were recorded as inverse figures of merit (FOMs). Visual rankings of image differences by five human observers of a subset (breast data only) also were performed to determine whether their subjective observations correlated with homologous FOMs. Nonparametric statistical analysis of these data demonstrated significant differences (P > 0.05) between reconstruction algorithms. The nonlinear minimization reconstruction method nearly always outperformed the other methods tested. Observer rankings were similar to those measured objectively.
NASA Astrophysics Data System (ADS)
Valeja, Santosh G.; Emmett, Mark R.; Marshall, Alan G.
2012-04-01
Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein-protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.
ERIC Educational Resources Information Center
Burzynska, Kamila
2012-01-01
The Internet provides a powerful digital learning environment for language acquisition and noticing. Thus implementation of challenging tasks to be solved by exploring the Web may sound appealing. The primary idea of the WebQuest project emphasizes data collection. The idea of the TalenQuest, however, goes beyond this traditional concept so as to…
Keawduangdee, Petcharat; Puntumetakul, Rungthip; Swangnetr, Manida; Laohasiriwong, Wongsa; Settheetham, Dariwan; Yamauchi, Junichiro; Boucaut, Rose
2015-01-01
[Purpose] The aim of this study was to investigate the prevalence of low back pain and associated factors in Thai rice farmers during the rice transplanting process. [Subjects and Methods] Three hundred and forty-four farmers, aged 20–59 years old, were asked to answer a questionnaire modified from the Standard Nordic Questionnaire (Thai version). The questionnaire sought demographic, back-related, and psychosocial data. [Results] The results showed that the prevalence of low back pain was 83.1%. Farmers younger than 45 years old who worked in the field fewer than six days were more likely to experience low back pain than those who worked for at least six days. Farmers with high stress levels were more likely to have low back pain. [Conclusion] In the rice transplanting process, the low back pain experienced by the farmers was associated with the weekly work duration and stress. PMID:26311961
NASA Astrophysics Data System (ADS)
Di, K.; Liu, Y.; Liu, B.; Peng, M.
2012-07-01
Chang'E-1(CE-1) and Chang'E-2(CE-2) are the two lunar orbiters of China's lunar exploration program. Topographic mapping using CE-1 and CE-2 images is of great importance for scientific research as well as for preparation of landing and surface operation of Chang'E-3 lunar rover. In this research, we developed rigorous sensor models of CE-1 and CE-2 CCD cameras based on push-broom imaging principle with interior and exterior orientation parameters. Based on the rigorous sensor model, the 3D coordinate of a ground point in lunar body-fixed (LBF) coordinate system can be calculated by space intersection from the image coordinates of con-jugate points in stereo images, and the image coordinates can be calculated from 3D coordinates by back-projection. Due to uncer-tainties of the orbit and the camera, the back-projected image points are different from the measured points. In order to reduce these inconsistencies and improve precision, we proposed two methods to refine the rigorous sensor model: 1) refining EOPs by correcting the attitude angle bias, 2) refining the interior orientation model by calibration of the relative position of the two linear CCD arrays. Experimental results show that the mean back-projection residuals of CE-1 images are reduced to better than 1/100 pixel by method 1 and the mean back-projection residuals of CE-2 images are reduced from over 20 pixels to 0.02 pixel by method 2. Consequently, high precision DEM (Digital Elevation Model) and DOM (Digital Ortho Map) are automatically generated.
Liu, Miao; Yang, Shourui; Wang, Zhangying; Huang, Shujun; Liu, Yue; Niu, Zhenqi; Zhang, Xiaoxuan; Zhu, Jigui; Zhang, Zonghua
2016-05-30
Augmented reality system can be applied to provide precise guidance for various kinds of manual works. The adaptability and guiding accuracy of such systems are decided by the computational model and the corresponding calibration method. In this paper, a novel type of augmented reality guiding system and the corresponding designing scheme are proposed. Guided by external positioning equipment, the proposed system can achieve high relative indication accuracy in a large working space. Meanwhile, the proposed system is realized with a digital projector and the general back projection model is derived with geometry relationship between digitized 3D model and the projector in free space. The corresponding calibration method is also designed for the proposed system to obtain the parameters of projector. To validate the proposed back projection model, the coordinate data collected by a 3D positioning equipment is used to calculate and optimize the extrinsic parameters. The final projecting indication accuracy of the system is verified with subpixel pattern projecting technique.
Toward automated analysis of particle holograms
NASA Technical Reports Server (NTRS)
Caulfield, H. J.
1987-01-01
A preliminary study of approaches for extracting and analyzing data from particle holograms is discussed. It concludes that: (1) for thin spherical particles, out-of-focus methods are optimum; (2) for thin nonspherical particles, out-of-focus methods are useful but must be supplemented by in-focus methods; (3) a complex method of projection and back projection can remove out-of-focus data for deep particles.
Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.
Wuest, W; May, M S; Brand, M; Bayerl, N; Krauss, A; Uder, M; Lell, M
2015-10-01
Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area. © 2015 by American Journal of Neuroradiology.
Bronx Zoo cogeneration project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivet, P.H.
The New York Zoological Society commenced feasibility studies for a proposed cogeneration and district heating system for the Bronz Zoo in spring 1982. Early studies focused on evaluating the Zoo's energy loads, infrastructure, and energy delivery and financing systems. The Zoological Society and New York City joined in the decision to support the construction of a system which would serve not only the Bronx Zoo but also five nearby City-funded installations, including the adjacent New York Botanical Garden. Since the submission of that study, the project has been modified in scope, scaling back to a generating capacity designed to servemore » only the Bronz Zoo.« less
FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector.
Schäfer, Dirk; Grass, Michael; van de Haar, Peter
2011-07-01
Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.
1989-08-18
Calabro, 1982; Macrae & Wright, 1969) and other forms of arthritis (Schober, 1937). Clinicians also use measurements of lumbar flexion to help determine...Clinical Biomechanics, 1, 20-26. Buswell, J. (1982). Low back pain: A comparison of two treatment programmes. New Zealand Journal of Physiotherapy ...Gilles, J., Haldeman, J. & Patterson, C. (1975). Low back pain: A study of 50 patients on a group exercise program. Physiotherapy Canada, 27. 71-77
The influence of unstable modified wall squat exercises on the posture of female university students
Lee, Yoonmi
2015-01-01
[Purpose] The purpose of this study was to examine the effect of unstable modified wall squat exercises on the posture of female university students. [Subjects] The subjects of this study were 30 female university students who were equally and randomly allocated to an unstable modified wall squat exercises group the experimental group and a stable modified wall squat exercises group the control group. [Methods] Both groups performed their respective exercises for 30 minutes three times per week over a six-week period. Using BackMapper, trunk inclination, trunk imbalance, pelvic position, pelvic torsion, pelvic rotation, and position of the scapulae were evaluated. [Results] The unstable modified wall squat exercises group obtained significant results for trunk inclination, trunk imbalance, pelvic position, pelvic torsion, position of the scapulae, while the stable modified wall squat exercises group obtained significant results for trunk imbalance and pelvic position. [Conclusion] Unstable modified wall squat exercises may be applied as a method to correct the posture of average adults. PMID:26356770
From Genomes to Protein Models and Back
NASA Astrophysics Data System (ADS)
Tramontano, Anna; Giorgetti, Alejandro; Orsini, Massimiliano; Raimondo, Domenico
2007-12-01
The alternative splicing mechanism allows genes to generate more than one product. When the splicing events occur within protein coding regions they can modify the biological function of the protein. Alternative splicing has been suggested as one way for explaining the discrepancy between the number of human genes and functional complexity. We analysed the putative structure of the alternatively spliced gene products annotated in the ENCODE pilot project and discovered that many of the potential alternative gene products will be unlikely to produce stable functional proteins.
NASA Astrophysics Data System (ADS)
Pathan, H. M.; Lokhande, C. D.; Amalnerkar, D. P.; Seth, T.
2003-09-01
Copper telluride thin films were deposited using modified chemical method using copper(II) sulphate; pentahydrate [CuSO 4·5H 2O] and sodium tellurite [Na 2TeO 3] as cationic and anionic sources, respectively. Modified chemical method is based on the immersion of the substrate into separately placed cationic and anionic precursors. The preparative conditions such as concentration, pH, immersion time, immersion cycles, etc. were optimized to get good quality copper telluride thin films at room temperature. The films have been characterized for structural, compositional, optical and electrical transport properties by means of X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDAX), Rutherford back scattering (RBS), optical absorption/transmission, electrical resistivity and thermoemf measurement techniques.
Method Accelerates Training Of Some Neural Networks
NASA Technical Reports Server (NTRS)
Shelton, Robert O.
1992-01-01
Three-layer networks trained faster provided two conditions are satisfied: numbers of neurons in layers are such that majority of work done in synaptic connections between input and hidden layers, and number of neurons in input layer at least as great as number of training pairs of input and output vectors. Based on modified version of back-propagation method.
Rubber-Modified Epoxy and Glass Laminates for Application to Naval Ship Structures.
1983-09-01
more information. Two generic carboxy terminated butadiene acrylonitrile ( CTBN )-modified epoxy/glass cloth material systems have been characterized...versus Normal Impact Energy of 7781-Z6040/Fl55 .......... .................... 8 4 - Front Surface of CTBN -Modified Epoxy GRP Panel After 60 Impacts at...15 6 - Back Surface of CTBN -Modified Epoxy GRP Panel After 60 Impacts at 206 Foot-Pounds ..... .................. ... 16 7 - Back Surface of
A reconstruction method for cone-beam differential x-ray phase-contrast computed tomography.
Fu, Jian; Velroyen, Astrid; Tan, Renbo; Zhang, Junwei; Chen, Liyuan; Tapfer, Arne; Bech, Martin; Pfeiffer, Franz
2012-09-10
Most existing differential phase-contrast computed tomography (DPC-CT) approaches are based on three kinds of scanning geometries, described by parallel-beam, fan-beam and cone-beam. Due to the potential of compact imaging systems with magnified spatial resolution, cone-beam DPC-CT has attracted significant interest. In this paper, we report a reconstruction method based on a back-projection filtration (BPF) algorithm for cone-beam DPC-CT. Due to the differential nature of phase contrast projections, the algorithm restrains from differentiation of the projection data prior to back-projection, unlike BPF algorithms commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a micro-focus x-ray tube source. Moreover, the numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated cone-beam datasets. We believe that this feature is of particular interest for future medical cone-beam phase-contrast CT imaging applications.
The Validity of the Modified Sit-and-Reach Test in College-Age Students.
ERIC Educational Resources Information Center
Minkler, Sharin; Patterson, Patricia
1994-01-01
Reports a study that examined the criterion-related validity of the modified sit-and-reach test against criterion measures of hamstring and low back flexibility in college students. Results indicated the modified sit-and-reach test moderately related to hamstring flexibility, but its relation to low back flexibility was low. (SM)
A reinterpretation of the data from the NASA Stratosphere-Troposphere Exchange Project
NASA Astrophysics Data System (ADS)
Newman, Paul A.; Schoeberl, Mark R.
Data obtained during the NASA Stratosphere Troposphere Exchange Project (STEP) Mid-Latitude Field Experiment displayed laminae of ozone, water, and condensation nuclei in the stratosphere in association with a mid-latitude stratosphere-troposphere folding event. Danielsen et al. (1991) constructed cross sections of these observations, and interpreted these quasi-horizontal laminae as evidence of ultra-low frequency gravity waves. We use a new technique to show that these laminae could have resulted from differential advection, rather than transport by ultra-low frequency gravity waves. This new technique uses reverse domain filling back trajectories on multiple isentropic surfaces in conjunction with modified potential vorticity to reveal the qualitative details of the constituent laminae.
A Novel General Imaging Formation Algorithm for GNSS-Based Bistatic SAR.
Zeng, Hong-Cheng; Wang, Peng-Bo; Chen, Jie; Liu, Wei; Ge, LinLin; Yang, Wei
2016-02-26
Global Navigation Satellite System (GNSS)-based bistatic Synthetic Aperture Radar (SAR) recently plays a more and more significant role in remote sensing applications for its low-cost and real-time global coverage capability. In this paper, a general imaging formation algorithm was proposed for accurately and efficiently focusing GNSS-based bistatic SAR data, which avoids the interpolation processing in traditional back projection algorithms (BPAs). A two-dimensional point target spectrum model was firstly presented, and the bulk range cell migration correction (RCMC) was consequently derived for reducing range cell migration (RCM) and coarse focusing. As the bulk RCMC seriously changes the range history of the radar signal, a modified and much more efficient hybrid correlation operation was introduced for compensating residual phase errors. Simulation results were presented based on a general geometric topology with non-parallel trajectories and unequal velocities for both transmitter and receiver platforms, showing a satisfactory performance by the proposed method.
A Novel General Imaging Formation Algorithm for GNSS-Based Bistatic SAR
Zeng, Hong-Cheng; Wang, Peng-Bo; Chen, Jie; Liu, Wei; Ge, LinLin; Yang, Wei
2016-01-01
Global Navigation Satellite System (GNSS)-based bistatic Synthetic Aperture Radar (SAR) recently plays a more and more significant role in remote sensing applications for its low-cost and real-time global coverage capability. In this paper, a general imaging formation algorithm was proposed for accurately and efficiently focusing GNSS-based bistatic SAR data, which avoids the interpolation processing in traditional back projection algorithms (BPAs). A two-dimensional point target spectrum model was firstly presented, and the bulk range cell migration correction (RCMC) was consequently derived for reducing range cell migration (RCM) and coarse focusing. As the bulk RCMC seriously changes the range history of the radar signal, a modified and much more efficient hybrid correlation operation was introduced for compensating residual phase errors. Simulation results were presented based on a general geometric topology with non-parallel trajectories and unequal velocities for both transmitter and receiver platforms, showing a satisfactory performance by the proposed method. PMID:26927117
de Lima, Camila; Salomão Helou, Elias
2018-01-01
Iterative methods for tomographic image reconstruction have the computational cost of each iteration dominated by the computation of the (back)projection operator, which take roughly O(N 3 ) floating point operations (flops) for N × N pixels images. Furthermore, classical iterative algorithms may take too many iterations in order to achieve acceptable images, thereby making the use of these techniques unpractical for high-resolution images. Techniques have been developed in the literature in order to reduce the computational cost of the (back)projection operator to O(N 2 logN) flops. Also, incremental algorithms have been devised that reduce by an order of magnitude the number of iterations required to achieve acceptable images. The present paper introduces an incremental algorithm with a cost of O(N 2 logN) flops per iteration and applies it to the reconstruction of very large tomographic images obtained from synchrotron light illuminated data.
Phase 2 of the array automated assembly task for the low cost solar array project
NASA Technical Reports Server (NTRS)
Campbell, R. B.; Davis, J. R.; Ostroski, J. W.; Rai-Choudhury, P.; Rohatgi, A.; Seman, E. J.; Stapleton, R. E.
1979-01-01
The process sequence for the fabrication of dendritic web silicon into solar panels was modified to include aluminum back surface field formation. Plasma etching was found to be a feasible technique for pre-diffusion cleaning of the web. Several contacting systems were studied. The total plated Pd-Ni system was not compatible with the process sequence; however, the evaporated TiPd-electroplated Cu system was shown stable under life testing. Ultrasonic bonding parameters were determined for various interconnect and contact metals but the yield of the process was not sufficiently high to use for module fabrication at this time. Over 400 solar cells were fabricated according to the modified sequence. No sub-process incompatibility was seen. These cells were used to fabricate four demonstration modules. A cost analysis of the modified process sequence resulted in a selling price of $0.75/peak watt.
Color back projection for fruit maturity evaluation
NASA Astrophysics Data System (ADS)
Zhang, Dong; Lee, Dah-Jye; Desai, Alok
2013-12-01
In general, fruits and vegetables such as tomatoes and dates are harvested before they fully ripen. After harvesting, they continue to ripen and their color changes. Color is a good indicator of fruit maturity. For example, tomatoes change color from dark green to light green and then pink, light red, and dark red. Assessing tomato maturity helps maximize its shelf life. Color is used to determine the length of time the tomatoes can be transported. Medjool dates change color from green to yellow, and the orange, light red and dark red. Assessing date maturity helps determine the length of drying process to help ripen the dates. Color evaluation is an important step in the processing and inventory control of fruits and vegetables that directly affects profitability. This paper presents an efficient color back projection and image processing technique that is designed specifically for real-time maturity evaluation of fruits. This color processing method requires very simple training procedure to obtain the frequencies of colors that appear in each maturity stage. This color statistics is used to back project colors to predefined color indexes. Fruit maturity is then evaluated by analyzing the reprojected color indexes. This method has been implemented and used for commercial production.
Zooming in on vibronic structure by lowest-value projection reconstructed 4D coherent spectroscopy
NASA Astrophysics Data System (ADS)
Harel, Elad
2018-05-01
A fundamental goal of chemical physics is an understanding of microscopic interactions in liquids at and away from equilibrium. In principle, this microscopic information is accessible by high-order and high-dimensionality nonlinear optical measurements. Unfortunately, the time required to execute such experiments increases exponentially with the dimensionality, while the signal decreases exponentially with the order of the nonlinearity. Recently, we demonstrated a non-uniform acquisition method based on radial sampling of the time-domain signal [W. O. Hutson et al., J. Phys. Chem. Lett. 9, 1034 (2018)]. The four-dimensional spectrum was then reconstructed by filtered back-projection using an inverse Radon transform. Here, we demonstrate an alternative reconstruction method based on the statistical analysis of different back-projected spectra which results in a dramatic increase in sensitivity and at least a 100-fold increase in dynamic range compared to conventional uniform sampling and Fourier reconstruction. These results demonstrate that alternative sampling and reconstruction methods enable applications of increasingly high-order and high-dimensionality methods toward deeper insights into the vibronic structure of liquids.
Does thorax EIT image analysis depend on the image reconstruction method?
NASA Astrophysics Data System (ADS)
Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut
2013-04-01
Different methods were proposed to analyze the resulting images of electrical impedance tomography (EIT) measurements during ventilation. The aim of our study was to examine if the analysis methods based on back-projection deliver the same results when applied on images based on other reconstruction algorithms. Seven mechanically ventilated patients with ARDS were examined by EIT. The thorax contours were determined from the routine CT images. EIT raw data was reconstructed offline with (1) filtered back-projection with circular forward model (BPC); (2) GREIT reconstruction method with circular forward model (GREITC) and (3) GREIT with individual thorax geometry (GREITT). Three parameters were calculated on the resulting images: linearity, global ventilation distribution and regional ventilation distribution. The results of linearity test are 5.03±2.45, 4.66±2.25 and 5.32±2.30 for BPC, GREITC and GREITT, respectively (median ±interquartile range). The differences among the three methods are not significant (p = 0.93, Kruskal-Wallis test). The proportions of ventilation in the right lung are 0.58±0.17, 0.59±0.20 and 0.59±0.25 for BPC, GREITC and GREITT, respectively (p = 0.98). The differences of the GI index based on different reconstruction methods (0.53±0.16, 0.51±0.25 and 0.54±0.16 for BPC, GREITC and GREITT, respectively) are also not significant (p = 0.93). We conclude that the parameters developed for images generated with GREITT are comparable with filtered back-projection and GREITC.
FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer, Dirk; Grass, Michael; Haar, Peter van de
2011-05-15
Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting andmore » back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.« less
Scholtes, Sara A.; Norton, Barbara J.; Lang, Catherine E.; Van Dillen, Linda R.
2010-01-01
The purpose of the current study was to examine how effectively people with and people without low back pain (LBP) modify lumbopelvic motion during a limb movement test. Nineteen subjects with LBP and 20 subjects without LBP participated. Kinematic data were collected while subjects performed active hip lateral rotation (HLR) in prone. Subjects completed trials (1) using their natural method (Natural condition) of performing HLR, and (2) following standardized instructions to modify lumbopelvic motion while performing HLR (Modified condition). Variables of interest included (1) the amount of HLR completed prior to the start of lumbopelvic motion, and (2) the maximum amount of lumbopelvic motion demonstrated during HLR. Compared to the Natural Condition, all subjects improved their performance during the Modified condition by (1) completing a greater amount of HLR prior to the start of lumbopelvic motion, and (2) demonstrating less lumbopelvic motion (P<0.01 for all comparisons). There was a tendency for people without LBP to demonstrate a greater difference in maximal lumbopelvic rotation between the Natural and Modified conditions (P=0.07). In conclusion, people are able to modify lumbopelvic motion following instruction. Further study is needed to determine if people without LBP improve lumbopelvic motion following instruction to a greater extent than people with LBP. PMID:20627798
Atom probe trajectory mapping using experimental tip shape measurements.
Haley, D; Petersen, T; Ringer, S P; Smith, G D W
2011-11-01
Atom probe tomography is an accurate analytical and imaging technique which can reconstruct the complex structure and composition of a specimen in three dimensions. Despite providing locally high spatial resolution, atom probe tomography suffers from global distortions due to a complex projection function between the specimen and detector which is different for each experiment and can change during a single run. To aid characterization of this projection function, this work demonstrates a method for the reverse projection of ions from an arbitrary projection surface in 3D space back to an atom probe tomography specimen surface. Experimental data from transmission electron microscopy tilt tomography are combined with point cloud surface reconstruction algorithms and finite element modelling to generate a mapping back to the original tip surface in a physically and experimentally motivated manner. As a case study, aluminium tips are imaged using transmission electron microscopy before and after atom probe tomography, and the specimen profiles used as input in surface reconstruction methods. This reconstruction method is a general procedure that can be used to generate mappings between a selected surface and a known tip shape using numerical solutions to the electrostatic equation, with quantitative solutions to the projection problem readily achievable in tens of minutes on a contemporary workstation. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.
Nurminen, M
1997-11-01
To re-examine the relation between heavy physical work and the occurrence of sciatic pain among construction workers reported previously to be absent in an epidemiological study. METHODS-Poisson log linear regression was used to model for the frequency of sciatic pain among concrete reinforcement workers and maintenance house painters with adjustment for the interactive effects of earlier back accidents and aging that modified the relation. Concrete reinforcement work not only had a direct effect on the frequency of sciatic pain, but it also contributed significantly to the risk indirectly through earlier back accidents. The risk of sciatic pain increased from age 25 to 54 in a different manner for a worker depending on his occupational group and record of back accidents. Epidemiological studies on low back pain need to be analysed with sound methodology. This is important in view of future meta-analyses that will be performed for the purpose of providing guidelines on the prevention of back disorders in heavy physical work.
Immediate effects of dynamic sitting exercise on the lower back mobility of sedentary young adults
Chatchawan, Uraiwan; Jupamatangb, Unthika; Chanchitc, Sunisa; Puntumetakul, Rungthip; Donpunha, Wanida; Yamauchi, Junichiro
2015-01-01
[Purpose] The aim of this study was to investigate the effects of dynamic sitting exercises during prolonged sitting on the lower back mobility of sedentary young adults. [Subjects and Methods] Seventy-one subjects aged between 18–25 years participated in this study. Following a randomized crossover study design, subjects were randomly assigned to two groups: sitting only and dynamic sitting exercise. The dynamic sitting exercise was a combination of lower back hyperextension and abdominal drawing-in movements which were repeated 6 times in a 1-minute period and performed every 20 minutes during a 2-hour sitting session. Lumbar range of movement was measured with the modified-modified Schober test, and the pain intensity was evaluated using the visual analog scale. [Results] After the experiment, the lumbar range of movement was significantly impaired in the sitting only group; however, it was significantly improved in the dynamic sitting exercise group. There were significant differences in lumbar range of movement of both flexion and extension between the groups. No significant difference in pain intensity between the groups was found. [Conclusion] These results suggest that dynamic sitting exercises during prolonged sitting can prevent decreases in lumbar range of movement in both back flexion and extension following a 2-hour sitting period. PMID:26696698
Interrelations between random walks on diagrams (graphs) with and without cycles.
Hill, T L
1988-05-01
Three topics are discussed. A discrete-state, continuous-time random walk with one or more absorption states can be studied by a presumably new method: some mean properties, including the mean time to absorption, can be found from a modified diagram (graph) in which each absorption state is replaced by a one-way cycle back to the starting state. The second problem is a random walk on a diagram (graph) with cycles. The walk terminates on completion of the first cycle. This walk can be replaced by an equivalent walk on a modified diagram with absorption. This absorption diagram can in turn be replaced by another modified diagram with one-way cycles back to the starting state, just as in the first problem. The third problem, important in biophysics, relates to a long-time continuous walk on a diagram with cycles. This diagram can be transformed (in two steps) to a modified, more-detailed, diagram with one-way cycles only. Thus, the one-way cycle fluxes of the original diagram can be found from the state probabilities of the modified diagram. These probabilities can themselves be obtained by simple matrix inversion (the probabilities are determined by linear algebraic steady-state equations). Thus, a simple method is now available to find one-way cycle fluxes exactly (previously Monte Carlo simulation was required to find these fluxes, with attendant fluctuations, for diagrams of any complexity). An incidental benefit of the above procedure is that it provides a simple proof of the one-way cycle flux relation Jn +/- = IIn +/- sigma n/sigma, where n is any cycle of the original diagram.
Sakhteman, Amirhossein; Faridi, Pouya; Daneshamouz, Saeid; Akbarizadeh, Amin Reza; Borhani-Haghighi, Afshin; Mohagheghzadeh, Abdolali
2017-01-01
Herbal oils have been widely used in Iran as medicinal compounds dating back to thousands of years in Iran. Chamomile oil is widely used as an example of traditional oil. We remade chamomile oils and tried to modify it with current knowledge and facilities. Six types of oil (traditional and modified) were prepared. Microbial limit tests and physicochemical tests were performed on them. Also, principal component analysis, hierarchical cluster analysis, and partial least squares discriminant analysis were done on the spectral data of attenuated total reflectance–infrared in order to obtain insight based on classification pattern of the samples. The results show that we can use modified versions of the chamomile oils (modified Clevenger-type apparatus method and microwave method) with the same content of traditional ones and with less microbial contaminations and better physicochemical properties. PMID:28585466
Zargaran, Arman; Sakhteman, Amirhossein; Faridi, Pouya; Daneshamouz, Saeid; Akbarizadeh, Amin Reza; Borhani-Haghighi, Afshin; Mohagheghzadeh, Abdolali
2017-10-01
Herbal oils have been widely used in Iran as medicinal compounds dating back to thousands of years in Iran. Chamomile oil is widely used as an example of traditional oil. We remade chamomile oils and tried to modify it with current knowledge and facilities. Six types of oil (traditional and modified) were prepared. Microbial limit tests and physicochemical tests were performed on them. Also, principal component analysis, hierarchical cluster analysis, and partial least squares discriminant analysis were done on the spectral data of attenuated total reflectance-infrared in order to obtain insight based on classification pattern of the samples. The results show that we can use modified versions of the chamomile oils (modified Clevenger-type apparatus method and microwave method) with the same content of traditional ones and with less microbial contaminations and better physicochemical properties.
NASA Astrophysics Data System (ADS)
Lough, A. C.; Roman, D. C.; Haney, M. M.
2015-12-01
Deep long period (DLP) earthquakes are commonly observed in volcanic settings such as the Aleutian Arc in Alaska. DLPs are poorly understood but are thought to be associated with movements of fluids, such as magma or hydrothermal fluids, deep in the volcanic plumbing system. These events have been recognized for several decades but few studies have gone beyond their identification and location. All long period events are more difficult to identify and locate than volcano-tectonic (VT) earthquakes because traditional detection schemes focus on high frequency (short period) energy. In addition, DLPs present analytical challenges because they tend to be emergent and so it is difficult to accurately pick the onset of arriving body waves. We now expect to find DLPs at most volcanic centers, the challenge lies in identification and location. We aim to reduce the element of human error in location by applying back projection to better constrain the depth and horizontal position of these events. Power et al. (2004) provided the first compilation of DLP activity in the Aleutian Arc. This study focuses on the reanalysis of 162 cataloged DLPs beneath 11 volcanoes in the Aleutian arc (we expect to ultimately identify and reanalyze more DLPs). We are currently adapting the approach of Haney (2014) for volcanic tremor to use back projection over a 4D grid to determine position and origin time of DLPs. This method holds great potential in that it will allow automated, high-accuracy picking of arrival times and could reduce the number of arrival time picks necessary for traditional location schemes to well constrain event origins. Back projection can also calculate a relative focal mechanism (difficult with traditional methods due to the emergent nature of DLPs) allowing the first in depth analysis of source properties. Our event catalog (spanning over 25 years and volcanoes) is one of the longest and largest and enables us to investigate spatial and temporal variation in DLPs.
NASA Astrophysics Data System (ADS)
Maghsoudi, M. H.; Zarei-Hanzaki, A.; Abedi, H. R.; Shamsolhodaei, A.
2015-11-01
Accumulative back extrusion (ABE) processing, as a novel severe plastic deformation (SPD) method, has been recently justified to be capable of modifying the microstructural characteristics of alloys. In line to its ongoing researches, the present work has been planned to study the evolution of γ-Mg17Al12 intermetallic phase during ABE and subsequent ageing treatment in a high Al-bearing Mg-Al-Zn alloy. The behaviour of γ intermetallic has been systematically examined as following points of view: (i) strain-temperature-dependent morphology changes, (ii) strain-induced dissolution, and (iii) re-ageing behaviour as a function of time and temperature. Aiming to analyse the morphology of eutectic γ compound with respect to the strain and temperature, 2D projections of effective diameter, shape factor and globularity have been made in strain/temperature graphs. The processing conditions (strain and temperature) corresponding to the desired and undesired morphologies are introduced and microstructurally explained through underlying plasticity mechanisms, i.e., 'necking-thinning-particle separation' and 'brittle fragmentation.' The former mechanism is suggested to be in relation with partial strain-induced dissolution of eutectic γ phase, leading to generation of a supersaturated solid solution. This has resulted to the observation of 'off-stoichiometry' phenomena in Mg17Al12 phase and has been justified through dislocation-assisted deformation mechanism at elevated temperature. Surprisingly, a unique re-ageing behaviour has been found for the obtained solid solutions, where a modified kinetics and morphology of γ phase precipitation were characterized. The altered precipitation behaviour is attributed to the specific defect structure achieved by SPD acting as fast diffusion channel for Al solutes.
NASA Astrophysics Data System (ADS)
Peng, Cheng; Geneva, Nicholas; Guo, Zhaoli; Wang, Lian-Ping
2017-01-01
In lattice Boltzmann simulations involving moving solid boundaries, the momentum exchange between the solid and fluid phases was recently found to be not fully consistent with the principle of local Galilean invariance (GI) when the bounce-back schemes (BBS) and the momentum exchange method (MEM) are used. In the past, this inconsistency was resolved by introducing modified MEM schemes so that the overall moving-boundary algorithm could be more consistent with GI. However, in this paper we argue that the true origin of this violation of Galilean invariance (VGI) in the presence of a moving solid-fluid interface is due to the BBS itself, as the VGI error not only exists in the hydrodynamic force acting on the solid phase, but also in the boundary force exerted on the fluid phase, according to Newton's Third Law. The latter, however, has so far gone unnoticed in previously proposed modified MEM schemes. Based on this argument, we conclude that the previous modifications to the momentum exchange method are incomplete solutions to the VGI error in the lattice Boltzmann method (LBM). An implicit remedy to the VGI error in the LBM and its limitation is then revealed. To address the VGI error for a case when this implicit remedy does not exist, a bounce-back scheme based on coordinate transformation is proposed. Numerical tests in both laminar and turbulent flows show that the proposed scheme can effectively eliminate the errors associated with the usual bounce-back implementations on a no-slip solid boundary, and it can maintain an accurate momentum exchange calculation with minimal computational overhead.
Pitcher, Mark J.; Behm, David G.; MacKinnon, Scott N.
2007-01-01
Studies employing modified Biering-Sørenson tests have reported that low back endurance is related to the potential for developing low back pain. Understanding the manner in which spinal musculature fatigues in people with and without LBP is necessary to gain insight into the sensitivity of the modified Biering-Sørenson test to differentiate back health. Twenty male volunteers were divided into a LBP group of subjects with current subacute or a history of LBP that limited their activity (n = 10) and a control group (n = 10). The median frequency of the fast Fourier transform was calculated from bilateral surface electromyography (EMG) of the upper lumbar erector spinae (ULES), lower lumbar erector spinae (LLES) and biceps femoris while maintaining a prescribed modified Biering-Sørensen test position and exerting isometric forces equivalent to 100, 120, 140 and 160% of the estimated mass of the head-arms-trunk (HAT) segment. Time to failure was also investigated across the percentages of HAT. Fatigue time decreased with increasing load and differences between groups increased as load increased, however these differences were not significant. Significant differences in the EMG median frequency between groups occurred in the right biceps femoris (p ≤ 0.05) with significant pairwise differences occurring at 140% for the left biceps femoris and at 160% for the right biceps femoris. There were significant pairwise differences at 120% for average EMG of the right biceps femoris and at 140% for the right ULES, and right and left biceps femoris (p ≤ 0.05). The modified Biering-Sørensen test as usually performed at 100% HAT is not sufficient to demonstrate significant differences between controls and subjects with varying degrees of mild back disability based on the Oswestry classification. Key pointsThe results do not wholly support the modified Biering-Sørensen test utilizing resistance of 100% HAT to discern differences in fatigue in subjects with mild low back pain.A greater activation of the biceps femoris by low back pain individuals probably contributed to the lack of significant differences in back fatigue times.The possibility exists that subjects with more sophisticated strategies could yield higher fatigue times despite inferior neuromuscular fatigue and the existence of low back pain. PMID:24149491
The Impact of Obesity on Back and Core Muscular Endurance in Firefighters
Mayer, John M.; Nuzzo, James L.; Chen, Ren; Quillen, William S.; Verna, Joe L.; Miro, Rebecca; Dagenais, Simon
2012-01-01
The purpose of this study was to assess the relationships between obesity and measures of back and core muscular endurance in firefighters. Methods. A cross-sectional study was conducted in career firefighters without low back pain. Obesity measures included body mass index (BMI) and body fat percentage assessed with air displacement plethysmography. Muscular endurance was assessed with the Modified Biering Sorensen (back) and Plank (core) tests. Relationships were explored using t-tests and regression analyses. Results. Of the 83 participants enrolled, 24 (29%) were obese (BMI ≥ 30). Back and core muscular endurance was 27% lower for obese participants. Significant negative correlations were observed for BMI and body fat percentage with back and core endurance (r = −0.42 to −0.52). Stepwise regression models including one obesity measure (BMI, body fat percentage, and fat mass/fat-free mass), along with age and self-reported physical exercise, accounted for 17–19% of the variance in back muscular endurance and 29–37% of the variance in core muscular endurance. Conclusions. Obesity is associated with reduced back and core muscular endurance in firefighters, which may increase the risk of musculoskeletal injuries. Obesity should be considered along with back and core muscular endurance when designing exercise programs for back pain prevention in firefighters. PMID:23213491
Determination of lateral effects of borrow pits on hydrology of adjacent wetlands.
DOT National Transportation Integrated Search
2007-09-28
A three year research project was conducted to develop and test a method to predict the distance borrow pits should : be set back from adjacent wetlands to avoid detrimental impacts on wetland hydrology. The method is based on the : Boussinesq equati...
Robust method to detect and locate local earthquakes by means of amplitude measurements.
NASA Astrophysics Data System (ADS)
del Puy Papí Isaba, María; Brückl, Ewald
2016-04-01
In this study we present a robust new method to detect and locate medium and low magnitude local earthquakes. This method is based on an empirical model of the ground motion obtained from amplitude data of earthquakes in the area of interest, which were located using traditional methods. The first step of our method is the computation of maximum resultant ground velocities in sliding time windows covering the whole period of interest. In the second step, these maximum resultant ground velocities are back-projected to every point of a grid covering the whole area of interest while applying the empirical amplitude - distance relations. We refer to these back-projected ground velocities as pseudo-magnitudes. The number of operating seismic stations in the local network equals the number of pseudo-magnitudes at each grid-point. Our method introduces the new idea of selecting the minimum pseudo-magnitude at each grid-point for further analysis instead of searching for a minimum of the L2 or L1 norm. In case no detectable earthquake occurred, the spatial distribution of the minimum pseudo-magnitudes constrains the magnitude of weak earthquakes hidden in the ambient noise. In the case of a detectable local earthquake, the spatial distribution of the minimum pseudo-magnitudes shows a significant maximum at the grid-point nearest to the actual epicenter. The application of our method is restricted to the area confined by the convex hull of the seismic station network. Additionally, one must ensure that there are no dead traces involved in the processing. Compared to methods based on L2 and even L1 norms, our new method is almost wholly insensitive to outliers (data from locally disturbed seismic stations). A further advantage is the fast determination of the epicenter and magnitude of a seismic event located within a seismic network. This is possible due to the method of obtaining and storing a back-projected matrix, independent of the registered amplitude, for each seismic station. As a direct consequence, we are able to save computing time for the calculation of the final back-projected maximum resultant amplitude at every grid-point. The capability of the method was demonstrated firstly using synthetic data. In the next step, this method was applied to data of 43 local earthquakes of low and medium magnitude (1.7 < magnitude scale < 4.3). These earthquakes were recorded and detected by the seismic network ALPAACT (seismological and geodetic monitoring of Alpine PAnnonian ACtive Tectonics) in the period 2010/06/11 to 2013/09/20. Data provided by the ALPAACT network is used in order to understand seismic activity in the Mürz Valley - Semmering - Vienna Basin transfer fault system in Austria and what makes it such a relatively high earthquake hazard and risk area. The method will substantially support our efforts to involve scholars from polytechnic schools in seismological work within the Sparkling Science project Schools & Quakes.
Dual-tracer method to estimate coral reef response to a plume of chemically modified seawater
NASA Astrophysics Data System (ADS)
Maclaren, J. K.; Caldeira, K.
2013-12-01
We present a new method, based on measurement of seawater samples, to estimate the response of a reef ecosystem to a plume of an additive (for example, a nutrient or other chemical). In the natural environment, where there may be natural variability in concentrations, it can be difficult to distinguish between changes in concentrations that would occur naturally and changes in concentrations that result from a chemical addition. Furthermore, in the unconfined natural environment, chemically modified water can mix with waters that have not been modified, making it difficult to distinguish between effects of dilution and effects of chemical fluxes or transformations. We present a dual-tracer method that extracts signals from observations that may be affected by both natural variability and dilution. In this dual-tracer method, a substance (in our example case, alkalinity) is added to the water in known proportion to a passive conservative tracer (in our example case, Rhodamine WT dye). The resulting plume of seawater is allowed to flow over the study site. Two transects are drawn across the plume at the front and back of the study site. If, in our example, alkalinity is plotted as a function of dye concentration for the front transect, the slope of the resulting mixing line is the ratio of alkalinity to dye in the added fluid. If a similar mixing line is measured and calculated for the back transect, the slope of this mixing line will indicate the amount of added alkalinity that remains in the water flowing out of the study site per unit of added dye. The ratio of the front and back slopes indicates the fraction of added alkalinity that was taken up by the reef. The method is demonstrated in an experiment performed on One Tree Reef (Queensland, Australia) aimed at showing that ocean acidification is already affecting coral reef growth. In an effort to chemically reverse some of the changes to seawater chemistry that have occurred over the past 200 years, we added sodium hydroxide to increase alkalinity in the plume and controlled for dilution with Rhodamine WT dye. Preliminary data will be presented and analyzed using the approach described above.
2001-05-08
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Endeavour on top lifts off from Edwards Air Force Base to begin its ferry flight back to the Kennedy Space Center in Florida.
Cluster-modified function projective synchronisation of complex networks with asymmetric coupling
NASA Astrophysics Data System (ADS)
Wang, Shuguo
2018-02-01
This paper investigates the cluster-modified function projective synchronisation (CMFPS) of a generalised linearly coupled network with asymmetric coupling and nonidentical dynamical nodes. A novel synchronisation scheme is proposed to achieve CMFPS in community networks. We use adaptive control method to derive CMFPS criteria based on Lyapunov stability theory. Each cluster of networks is synchronised with target system by state transformation with scaling function matrix. Numerical simulation results are presented finally to illustrate the effectiveness of this method.
NASA Astrophysics Data System (ADS)
Thompson, John D.; Chakraborty, Dev P.; Szczepura, Katy; Vamvakas, Ioannis; Tootell, Andrew; Manning, David J.; Hogg, Peter
2015-03-01
Purpose: To investigate the dose saving potential of iterative reconstruction (IR) in a computed tomography (CT) examination of the thorax. Materials and Methods: An anthropomorphic chest phantom containing various configurations of simulated lesions (5, 8, 10 and 12mm; +100, -630 and -800 Hounsfield Units, HU) was imaged on a modern CT system over a tube current range (20, 40, 60 and 80mA). Images were reconstructed with (IR) and filtered back projection (FBP). An ATOM 701D (CIRS, Norfolk, VA) dosimetry phantom was used to measure organ dose. Effective dose was calculated. Eleven observers (15.11+/-8.75 years of experience) completed a free response study, localizing lesions in 544 single CT image slices. A modified jackknife alternative free-response receiver operating characteristic (JAFROC) analysis was completed to look for a significant effect of two factors: reconstruction method and tube current. Alpha was set at 0.05 to control the Type I error in this study. Results: For modified JAFROC analysis of reconstruction method there was no statistically significant difference in lesion detection performance between FBP and IR when figures-of-merit were averaged over tube current (F(1,10)=0.08, p = 0.789). For tube current analysis, significant differences were revealed between multiple pairs of tube current settings (F(3,10) = 16.96, p<0.001) when averaged over image reconstruction method. Conclusion: The free-response study suggests that lesion detection can be optimized at 40mA in this phantom model, a measured effective dose of 0.97mSv. In high-contrast regions the diagnostic value of IR, compared to FBP, is less clear.
GPU-accelerated iterative reconstruction for limited-data tomography in CBCT systems.
de Molina, Claudia; Serrano, Estefania; Garcia-Blas, Javier; Carretero, Jesus; Desco, Manuel; Abella, Monica
2018-05-15
Standard cone-beam computed tomography (CBCT) involves the acquisition of at least 360 projections rotating through 360 degrees. Nevertheless, there are cases in which only a few projections can be taken in a limited angular span, such as during surgery, where rotation of the source-detector pair is limited to less than 180 degrees. Reconstruction of limited data with the conventional method proposed by Feldkamp, Davis and Kress (FDK) results in severe artifacts. Iterative methods may compensate for the lack of data by including additional prior information, although they imply a high computational burden and memory consumption. We present an accelerated implementation of an iterative method for CBCT following the Split Bregman formulation, which reduces computational time through GPU-accelerated kernels. The implementation enables the reconstruction of large volumes (>1024 3 pixels) using partitioning strategies in forward- and back-projection operations. We evaluated the algorithm on small-animal data for different scenarios with different numbers of projections, angular span, and projection size. Reconstruction time varied linearly with the number of projections and quadratically with projection size but remained almost unchanged with angular span. Forward- and back-projection operations represent 60% of the total computational burden. Efficient implementation using parallel processing and large-memory management strategies together with GPU kernels enables the use of advanced reconstruction approaches which are needed in limited-data scenarios. Our GPU implementation showed a significant time reduction (up to 48 ×) compared to a CPU-only implementation, resulting in a total reconstruction time from several hours to few minutes.
Identifying Treatment Effect Modifiers in the STarT Back Trial: A Secondary Analysis.
Beneciuk, Jason M; Hill, Jonathan C; Campbell, Paul; Afolabi, Ebenezer; George, Steven Z; Dunn, Kate M; Foster, Nadine E
2017-01-01
Identification of patient characteristics influencing treatment outcomes is a top low back pain (LBP) research priority. Results from the STarT Back trial support the effectiveness of prognostic stratified care for LBP compared with current best care, however, patient characteristics associated with treatment response have not yet been explored. The purpose of this secondary analysis was to identify treatment effect modifiers within the STarT Back trial at 4-month follow-up (n = 688). Treatment response was dichotomized using back-specific physical disability measured using the Roland-Morris Disability Questionnaire (≥7). Candidate modifiers were identified using previous literature and evaluated using logistic regression with statistical interaction terms to provide preliminary evidence of treatment effect modification. Socioeconomic status (SES) was identified as an effect modifier for disability outcomes (odds ratio [OR] = 1.71, P = .028). High SES patients receiving prognostic stratified care were 2.5 times less likely to have a poor outcome compared with low SES patients receiving best current care (OR = .40, P = .006). Education level (OR = 1.33, P = .109) and number of pain medications (OR = .64, P = .140) met our criteria for effect modification with weaker evidence (.20 > P ≥ .05). These findings provide preliminary evidence for SES, education, and number of pain medications as treatment effect modifiers of prognostic stratified care delivered in the STarT Back Trial. This analysis provides preliminary exploratory findings about the characteristics of patients who might least likely benefit from targeted treatment using prognostic stratified care for LBP. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.
Wang, Hongkai; Stout, David B; Chatziioannou, Arion F
2013-05-01
The development of sophisticated and high throughput whole body small animal imaging technologies has created a need for improved image analysis and increased automation. The registration of a digital mouse atlas to individual images is a prerequisite for automated organ segmentation and uptake quantification. This paper presents a fully-automatic method for registering a statistical mouse atlas with individual subjects based on an anterior-posterior X-ray projection and a lateral optical photo of the mouse silhouette. The mouse atlas was trained as a statistical shape model based on 83 organ-segmented micro-CT images. For registration, a hierarchical approach is applied which first registers high contrast organs, and then estimates low contrast organs based on the registered high contrast organs. To register the high contrast organs, a 2D-registration-back-projection strategy is used that deforms the 3D atlas based on the 2D registrations of the atlas projections. For validation, this method was evaluated using 55 subjects of preclinical mouse studies. The results showed that this method can compensate for moderate variations of animal postures and organ anatomy. Two different metrics, the Dice coefficient and the average surface distance, were used to assess the registration accuracy of major organs. The Dice coefficients vary from 0.31 ± 0.16 for the spleen to 0.88 ± 0.03 for the whole body, and the average surface distance varies from 0.54 ± 0.06 mm for the lungs to 0.85 ± 0.10mm for the skin. The method was compared with a direct 3D deformation optimization (without 2D-registration-back-projection) and a single-subject atlas registration (instead of using the statistical atlas). The comparison revealed that the 2D-registration-back-projection strategy significantly improved the registration accuracy, and the use of the statistical mouse atlas led to more plausible organ shapes than the single-subject atlas. This method was also tested with shoulder xenograft tumor-bearing mice, and the results showed that the registration accuracy of most organs was not significantly affected by the presence of shoulder tumors, except for the lungs and the spleen. Copyright © 2013 Elsevier B.V. All rights reserved.
Homeland Security Collaboration: Catch Phrase or Preeminent Organizational Construct?
2009-09-01
collaborative effort? C. RESEARCH METHODOLOGY This research project utilized a modified case study methodology. The traditional case study method ...discussing the research method , offering smart practices and culminate with findings and recommendations. Chapter II Homeland Security Collaboration...41 Centers for Regional Excellence, “Building Models.” 16 Chapter III Research Methodology: Modified Case Study Method is
2008-12-10
The Space Shuttle Endeavour atop its modified Boeing 747 carrier aircraft lifts off from Edwards Air Force Base on the first leg of its ferry flight back to the Kennedy Space Center just after sunrise on Dec. 10, 2008.
2008-12-10
The modified Boeing 747 carrier aircraft carrying the Space Shuttle Endeavour soars aloft from Edwards Air Force Base on the first leg of its ferry flight back to the Kennedy Space Center just after sunrise on Dec. 10, 2008.
2008-12-10
Moments after sunrise, the modified Boeing 747 carrier aircraft carrying the Space Shuttle Endeavour lifts off from Edwards Air Force Base on the first leg of its ferry flight back to the Kennedy Space Center on Dec. 10, 2008.
Schmelzer, Amy C; Salt, Elizabeth; Wiggins, Amanda; Crofford, Leslie J; Bush, Heather; Mannino, David M
2016-03-01
The purpose of this study was to examine the association between smoking and stress with nonpersistent and persistent back pain. Participants included 3703 women who took part in the Kentucky Women's Health Registry in 2008 and 2011. Multivariate logistic regression modeling was used to examine whether smoking status and stress levels were predictive of nonpersistent and persistent back pain, controlling for sociodemographic characteristics. Stress level was associated with both nonpersistent and persistent back pain, whereas smoking was associated with only persistent back pain. Current smokers were 1.5 times more likely to report persistent back pain compared with never smokers, controlling for age, race, body mass index, educational attainment, and employment status. Women experiencing large or overwhelming amounts of stress were 1.8 times more likely to have nonpersistent back pain and 1.6 times more likely to report persistent back pain, compared with women experiencing small amounts of stress. This study further substantiates the findings of prior research that describes a significant relationship between back pain, stress, and smoking. Understanding the role of modifiable risk factors (ie, smoking and stress) and their impact on back pain provides an opportunity to offer a comprehensive and tailored treatment plan.
Proposed test method for and evaluation of wheelchair seating system (WCSS) crashworthiness.
van Roosmalen, L; Bertocci, G; Ha, D R; Karg, P; Szobota, S
2000-01-01
Safety of motor vehicle seats is of great importance in providing crash protection to the occupant. An increasing number of wheelchair users use their wheelchairs as motor vehicle seats when traveling. A voluntary standard requires that compliant wheelchairs be dynamically sled impact tested. However, testing to evaluate the crashworthiness of add-on wheelchair seating systems (WCSS) independent of their wheelchair frame is not addressed by this standard. To address this need, this study developed a method to evaluate the crash-worthiness of WCSS with independent frames. Federal Motor Vehicle Safety Standards (FMVSS) 207 test protocols, used to test the strength of motor vehicle seats, were modified and used to test the strength of three WCSS. Forward and rearward loads were applied at the WCSS center of gravity (CGSS), and a moment was applied at the uppermost point of the seat back. Each of the three tested WCSS met the strength requirements of FMVSS 207. Wheelchair seat-back stiffness was also investigated and compared to motor vehicle seat-back stiffness.
Study protocol title: a prospective cohort study of low back pain
2013-01-01
Background Few prospective cohort studies of workplace low back pain (LBP) with quantified job physical exposure have been performed. There are few prospective epidemiological studies for LBP occupational risk factors and reported data generally have few adjustments for many personal and psychosocial factors. Methods/design A multi-center prospective cohort study has been incepted to quantify risk factors for LBP and potentially develop improved methods for designing and analyzing jobs. Due to the subjectivity of LBP, six measures of LBP are captured: 1) any LBP, 2) LBP ≥ 5/10 pain rating, 3) LBP with medication use, 4) LBP with healthcare provider visits, 5) LBP necessitating modified work duties and 6) LBP with lost work time. Workers have thus far been enrolled from 30 different employment settings in 4 diverse US states and performed widely varying work. At baseline, workers undergo laptop-administered questionnaires, structured interviews, and two standardized physical examinations to ascertain demographics, medical history, psychosocial factors, hobbies and physical activities, and current musculoskeletal disorders. All workers’ jobs are individually measured for physical factors and are videotaped. Workers are followed monthly for the development of low back pain. Changes in jobs necessitate re-measure and re-videotaping of job physical factors. The lifetime cumulative incidence of low back pain will also include those with a past history of low back pain. Incident cases will exclude prevalent cases at baseline. Statistical methods planned include survival analyses and logistic regression. Discussion Data analysis of a prospective cohort study of low back pain is underway and has successfully enrolled over 800 workers to date. PMID:23497211
NASA Astrophysics Data System (ADS)
Torres-Xirau, I.; Olaciregui-Ruiz, I.; Rozendaal, R. A.; González, P.; Mijnheer, B. J.; Sonke, J.-J.; van der Heide, U. A.; Mans, A.
2017-08-01
In external beam radiotherapy, electronic portal imaging devices (EPIDs) are frequently used for pre-treatment and for in vivo dose verification. Currently, various MR-guided radiotherapy systems are being developed and clinically implemented. Independent dosimetric verification is highly desirable. For this purpose we adapted our EPID-based dose verification system for use with the MR-Linac combination developed by Elekta in cooperation with UMC Utrecht and Philips. In this study we extended our back-projection method to cope with the presence of an extra attenuating medium between the patient and the EPID. Experiments were performed at a conventional linac, using an aluminum mock-up of the MRI scanner housing between the phantom and the EPID. For a 10 cm square field, the attenuation by the mock-up was 72%, while 16% of the remaining EPID signal resulted from scattered radiation. 58 IMRT fields were delivered to a 20 cm slab phantom with and without the mock-up. EPID reconstructed dose distributions were compared to planned dose distributions using the γ -evaluation method (global, 3%, 3 mm). In our adapted back-projection algorithm the averaged {γmean} was 0.27+/- 0.06 , while in the conventional it was 0.28+/- 0.06 . Dose profiles of several square fields reconstructed with our adapted algorithm showed excellent agreement when compared to TPS.
Inverse solutions for electrical impedance tomography based on conjugate gradients methods
NASA Astrophysics Data System (ADS)
Wang, M.
2002-01-01
A multistep inverse solution for two-dimensional electric field distribution is developed to deal with the nonlinear inverse problem of electric field distribution in relation to its boundary condition and the problem of divergence due to errors introduced by the ill-conditioned sensitivity matrix and the noise produced by electrode modelling and instruments. This solution is based on a normalized linear approximation method where the change in mutual impedance is derived from the sensitivity theorem and a method of error vector decomposition. This paper presents an algebraic solution of the linear equations at each inverse step, using a generalized conjugate gradients method. Limiting the number of iterations in the generalized conjugate gradients method controls the artificial errors introduced by the assumption of linearity and the ill-conditioned sensitivity matrix. The solution of the nonlinear problem is approached using a multistep inversion. This paper also reviews the mathematical and physical definitions of the sensitivity back-projection algorithm based on the sensitivity theorem. Simulations and discussion based on the multistep algorithm, the sensitivity coefficient back-projection method and the Newton-Raphson method are given. Examples of imaging gas-liquid mixing and a human hand in brine are presented.
Investigation of Back-Projection Uncertainties with M6 Earthquakes
NASA Astrophysics Data System (ADS)
Fan, W.; Shearer, P. M.
2017-12-01
We investigate possible biasing effects of inaccurate timing corrections on teleseismic P-wave back-projection imaging of large earthquake ruptures. These errors occur because empirically-estimated time shifts based on aligning P-wave first arrivals are exact only at the hypocenter and provide approximate corrections for other parts of the rupture. Using the Japan subduction zone as a test region, we analyze 46 M6-7 earthquakes over a ten-year period, including many aftershocks of the 2011 M9 Tohoku earthquake, performing waveform cross-correlation of their initial P-wave arrivals to obtain hypocenter timing corrections to global seismic stations. We then compare back-projection images for each earthquake using its own timing corrections with those obtained using the time corrections for other earthquakes. This provides a measure of how well sub-events can be resolved with back-projection of a large rupture as a function of distance from the hypocenter. Our results show that back-projection is generally very robust and that sub-event location errors average about 20 km across the entire study region ( 700 km). The back-projection coherence loss and location errors do not noticeably converge to zero even when the event pairs are very close (<20 km). This indicates that most of the timing differences are due to 3D structure close to each of the hypocenter regions, which limits the effectiveness of attempts to refine back-projection images using aftershock calibration, at least in this region.
Motta, Mario; Zhang, Shiwei
2017-11-14
We address the computation of ground-state properties of chemical systems and realistic materials within the auxiliary-field quantum Monte Carlo method. The phase constraint to control the Fermion phase problem requires the random walks in Slater determinant space to be open-ended with branching. This in turn makes it necessary to use back-propagation (BP) to compute averages and correlation functions of operators that do not commute with the Hamiltonian. Several BP schemes are investigated, and their optimization with respect to the phaseless constraint is considered. We propose a modified BP method for the computation of observables in electronic systems, discuss its numerical stability and computational complexity, and assess its performance by computing ground-state properties in several molecular systems, including small organic molecules.
Individual Participant Data Meta-Analysis of Mechanical Workplace Risk Factors and Low Back Pain
Shannon, Harry S.; Wells, Richard P.; Walter, Stephen D.; Cole, Donald C.; Côté, Pierre; Frank, John; Hogg-Johnson, Sheilah; Langlois, Lacey E.
2012-01-01
Objectives. We used individual participant data from multiple studies to conduct a comprehensive meta-analysis of mechanical exposures in the workplace and low back pain. Methods. We conducted a systematic literature search and contacted an author of each study to request their individual participant data. Because outcome definitions and exposure measures were not uniform across studies, we conducted 2 substudies: (1) to identify sets of outcome definitions that could be combined in a meta-analysis and (2) to develop methods to translate mechanical exposure onto a common metric. We used generalized estimating equation regression to analyze the data. Results. The odds ratios (ORs) for posture exposures ranged from 1.1 to 2.0. Force exposure ORs ranged from 1.4 to 2.1. The magnitudes of the ORs differed according to the definition of low back pain, and heterogeneity was associated with both study-level and individual-level characteristics. Conclusions. We found small to moderate ORs for the association of mechanical exposures and low back pain, although the relationships were complex. The presence of individual-level OR modifiers in such an area can be best understood by conducting a meta-analysis of individual participant data. PMID:22390445
NASA Astrophysics Data System (ADS)
Kelly, C. L.; Lawrence, J. F.
2014-12-01
During October 2012, 51 geophones and 6 broadband seismometers were deployed in an ~50x50m region surrounding a periodically erupting columnar geyser in the El Tatio Geyser Field, Chile. The dense array served as the seismic framework for a collaborative project to study the mechanics of complex hydrothermal systems. Contemporaneously, complementary geophysical measurements (including down-hole temperature and pressure, discharge rates, thermal imaging, water chemistry, and video) were also collected. Located on the western flanks of the Andes Mountains at an elevation of 4200m, El Tatio is the third largest geyser field in the world. Its non-pristine condition makes it an ideal location to perform minutely invasive geophysical studies. The El Jefe Geyser was chosen for its easily accessible conduit and extremely periodic eruption cycle (~120s). During approximately 2 weeks of continuous recording, we recorded ~2500 nighttime eruptions which lack cultural noise from tourism. With ample data, we aim to study how the source varies spatially and temporally during each phase of the geyser's eruption cycle. We are developing a new back-projection processing technique to improve source imaging for diffuse signals. Our method was previously applied to the Sierra Negra Volcano system, which also exhibits repeating harmonic and diffuse seismic sources. We back-project correlated seismic signals from the receivers back to their sources, assuming linear source to receiver paths and a known velocity model (obtained from ambient noise tomography). We apply polarization filters to isolate individual and concurrent geyser energy associated with P and S phases. We generate 4D, time-lapsed images of the geyser source field that illustrate how the source distribution changes through the eruption cycle. We compare images for pre-eruption, co-eruption, post-eruption and quiescent periods. We use our images to assess eruption mechanics in the system (i.e. top-down vs. bottom-up) and determine variations in source depth and distribution in the conduit and larger geyser field over many eruption cycles.
Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT.
Hahn, G; Just, A; Dudykevych, T; Frerichs, I; Hinz, J; Quintel, M; Hellige, G
2006-05-01
The increasing use of EIT in clinical research on severely ill lung patients requires a clarification of the influence of pathologic impedance distributions on the validity of the resulting tomograms. Significant accumulation of low-conducting air (e.g. pneumothorax or emphysema) or well-conducting liquid (e.g. haematothorax or atelectases) may conflict with treating the imaging problem as purely linear. First, we investigated the influence of stepwise inflation and deflation by up to 300 ml of air and 300 ml of Ringer solution into the pleural space of five pigs on the resulting tomograms during ventilation at constant tidal volume. Series of EIT images representing relative impedance changes were generated on the basis of a modified Sheffield back projection algorithm and ventilation distribution was displayed as functional (f-EIT) tomograms. In addition, a modified simultaneous iterative reconstruction technique (SIRT) was applied to quantify the resistivity distribution on an absolute level scaled in Omega m (a-EIT). Second, we applied these two EIT techniques on four intensive care patients with inhomogeneous air and fluid distribution and compared the EIT results to computed tomography (CT) and to a reference set of intrathoracic resistivity data of 20 healthy volunteers calculated by SIRT. The results of the animal model show that f-EIT based on back projection is not disturbed by the artificial pneumo- or haematothorax. Application of SIRT allows reliable discrimination and detection of the location and amplitude of pneumo- or haematothorax. These results were supported by the good agreement between the electrical impedance tomograms and CT scans on patients and by the significant differences of regional resistivity data between patients and healthy volunteers.
Quantum Dot Sensitized Solar Cells Based on Ternary Metal Oxide Nanowires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wenyong; Tang, Jinke; Dahnovsky, Yuri
In Phase I of this project we investigate quantum dot sensitized solar cells (QDSSCs) based on ternary metal oxide nanowires and study the physical and chemical mechanisms that govern device operation. Our research has the following five objectives: (1) synthesis of ternary metal oxide nanowires, (2) synthesis of QDs and exploration of non-solution based QD deposition methods, (3) physical and electro-optical characterizations of fabricated solar devices, (4) device modeling and first-principle theoretical study of transport physics, and (5) investigation of long-term stability issues of QD sensitized solar cells. In Phase II of this project our first major research goal ismore » to investigate magnetically doped quantum dots and related spin polarization effect, which could improve light absorption and suppress electron relaxation in the QDs. We will utilize both physical and chemical methods to synthesize these doped QDs. We will also study magnetically modified nanowires and introduce spin-polarized transport into QDSSCs, and inspect its impact on forward electron injection and back electron transfer processes. Our second goal is to study novel solid-state electrolytes for QDSSCs. Specifically, we will inspect a new type of polymer electrolytes based on a modified polysulfide redox couple, and examine the effect of their electrical properties on QDSSC performance. These solid-state electrolytes could also be used as filler materials for in situ sample fracturing in STM and enable cross-sectional interface examination of QD/nanowire structures. Our third research goal is to examine the interfacial properties such as energy level alignment at QD/nanowire interfaces using the newly developed Cross-sectional Scanning Tunneling Microscopy and Spectroscopy technique for non-cleavable materials. This technique allows a direct probing of band structures and alignment at device interfaces, which could generate important insight into the mechanisms that govern QDSSC operation. These investigations will be carried out through a close collaboration between our experimental and theoretical efforts in this project. This project initiates an important research direction in the jurisdiction of Wyoming. It brings together researchers from different academic disciplines including physics, chemistry, materials science, and engineering to work on one common scientific theme, and is a vital step towards the establishment of an nationally competitive research program in energy-related nanomaterials in the state of Wyoming.« less
Calculating the Financial Impact of Population Growth on Education.
ERIC Educational Resources Information Center
Cline, Daniel H.
It is particularly difficult to make accurate enrollment projections for areas that are experiencing a rapid expansion in their population. The traditional method of calculating cohort survival ratios must be modified and supplemented with additional information to ensure accuracy; cost projection methods require detailed analyses of current costs…
Reducing Artifacts in TMS-Evoked EEG
NASA Astrophysics Data System (ADS)
Fuertes, Juan José; Travieso, Carlos M.; Álvarez, A.; Ferrer, M. A.; Alonso, J. B.
Transcranial magnetic stimulation induces weak currents within the cranium to activate neuronal firing and its response is recorded using electroencephalography in order to study the brain directly. However, different artifacts contaminate the results. The goal of this study is to process these artifacts and reduce them digitally. Electromagnetic, blink and auditory artifacts are considered, and Signal-Space Projection, Independent Component Analysis and Wiener Filtering methods are used to reduce them. These last two produce a successful solution for electromagnetic artifacts. Regarding the other artifacts, processed with Signal-Space Projection, the method reduces the artifact but modifies the signal as well. Nonetheless, they are modified in an exactly known way and the vector used for the projection is conserved to be taken into account when analyzing the resulting signals. A system which combines the proposed methods would improve the quality of the information presented to physicians.
Semiautomated skeletonization of the pulmonary arterial tree in micro-CT images
NASA Astrophysics Data System (ADS)
Hanger, Christopher C.; Haworth, Steven T.; Molthen, Robert C.; Dawson, Christopher A.
2001-05-01
We present a simple and robust approach that utilizes planar images at different angular rotations combined with unfiltered back-projection to locate the central axes of the pulmonary arterial tree. Three-dimensional points are selected interactively by the user. The computer calculates a sub- volume unfiltered back-projection orthogonal to the vector connecting the two points and centered on the first point. Because more x-rays are absorbed at the thickest portion of the vessel, in the unfiltered back-projection, the darkest pixel is assumed to be the center of the vessel. The computer replaces this point with the newly computer-calculated point. A second back-projection is calculated around the original point orthogonal to a vector connecting the newly-calculated first point and user-determined second point. The darkest pixel within the reconstruction is determined. The computer then replaces the second point with the XYZ coordinates of the darkest pixel within this second reconstruction. Following a vector based on a moving average of previously determined 3- dimensional points along the vessel's axis, the computer continues this skeletonization process until stopped by the user. The computer estimates the vessel diameter along the set of previously determined points using a method similar to the full width-half max algorithm. On all subsequent vessels, the process works the same way except that at each point, distances between the current point and all previously determined points along different vessels are determined. If the difference is less than the previously estimated diameter, the vessels are assumed to branch. This user/computer interaction continues until the vascular tree has been skeletonized.
NASA Astrophysics Data System (ADS)
Kim, Chang-Won; Kim, Jong-Hyo
2011-03-01
Perfusion CT (PCT) examinations are getting more frequently used for diagnosis of acute brain diseases such as hemorrhage and infarction, because the functional map images it produces such as regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) may provide critical information in the emergency work-up of patient care. However, a typical PCT scans the same slices several tens of times after injection of contrast agent, which leads to much increased radiation dose and is inevitability of growing concern for radiation-induced cancer risk. Reducing the number of views in projection in combination of TV minimization reconstruction technique is being regarded as an option for radiation reduction. However, reconstruction artifacts due to insufficient number of X-ray projections become problematic especially when high contrast enhancement signals are present or patient's motion occurred. In this study, we present a novel reconstruction technique using contrast-adaptive TpV minimization that can reduce reconstruction artifacts effectively by using different p-norms in high contrast and low contrast objects. In the proposed method, high contrast components are first reconstructed using thresholded projection data and low p-norm total variation to reflect sparseness in both projection and reconstruction spaces. Next, projection data are modified to contain only low contrast objects by creating projection data of reconstructed high contrast components and subtracting them from original projection data. Then, the low contrast projection data are reconstructed by using relatively high p-norm TV minimization technique, and are combined with the reconstructed high contrast component images to produce final reconstructed images. The proposed algorithm was applied to numerical phantom and a clinical data set of brain PCT exam, and the resultant images were compared with those using filtered back projection (FBP) and conventional TV reconstruction algorithm. Our results show the potential of the proposed algorithm for image quality improvement, which in turn may lead to dose reduction.
Modifying the food supply at a community swimming pool: a case study.
Lloyd, Beverley; Dumbrell, Susan
2011-04-01
We report on a process evaluation of a project that aimed to replace energy-dense, nutrient-poor (EDNP) items at a community swimming pool kiosk. The analytic framework was the Analysis Grid for Environments Linked to Obesity (ANGELO). To contribute to health promotion practice in recreational settings, the process evaluation sought to determine the extent to which project'controversies' modified project objectives and strategies. The case study method captured the project narrative. The primary data were interviews with key project participants, supplemented with project records and media articles.These were analysed thematically. The socio-cultural and political environments, particularly the capacity to exercise choice in relation to ENDP products, had considerable influence on the project. In the face of two controversies -"I thought everyone was signed up to it"and "We can't deny the kiddies their ice-cream" it was necessary for the project partners to modify the objectives and strategies and substantially change the target. The setting is highly responsive to both the micro and macro socio-cultural and political aspects of the environment.
An accelerated training method for back propagation networks
NASA Technical Reports Server (NTRS)
Shelton, Robert O. (Inventor)
1993-01-01
The principal objective is to provide a training procedure for a feed forward, back propagation neural network which greatly accelerates the training process. A set of orthogonal singular vectors are determined from the input matrix such that the standard deviations of the projections of the input vectors along these singular vectors, as a set, are substantially maximized, thus providing an optimal means of presenting the input data. Novelty exists in the method of extracting from the set of input data, a set of features which can serve to represent the input data in a simplified manner, thus greatly reducing the time/expense to training the system.
Pang, Wai-Man; Qin, Jing; Lu, Yuqiang; Xie, Yongming; Chui, Chee-Kong; Heng, Pheng-Ann
2011-03-01
To accelerate the simultaneous algebraic reconstruction technique (SART) with motion compensation for speedy and quality computed tomography reconstruction by exploiting CUDA-enabled GPU. Two core techniques are proposed to fit SART into the CUDA architecture: (1) a ray-driven projection along with hardware trilinear interpolation, and (2) a voxel-driven back-projection that can avoid redundant computation by combining CUDA shared memory. We utilize the independence of each ray and voxel on both techniques to design CUDA kernel to represent a ray in the projection and a voxel in the back-projection respectively. Thus, significant parallelization and performance boost can be achieved. For motion compensation, we rectify each ray's direction during the projection and back-projection stages based on a known motion vector field. Extensive experiments demonstrate the proposed techniques can provide faster reconstruction without compromising image quality. The process rate is nearly 100 projections s (-1), and it is about 150 times faster than a CPU-based SART. The reconstructed image is compared against ground truth visually and quantitatively by peak signal-to-noise ratio (PSNR) and line profiles. We further evaluate the reconstruction quality using quantitative metrics such as signal-to-noise ratio (SNR) and mean-square-error (MSE). All these reveal that satisfactory results are achieved. The effects of major parameters such as ray sampling interval and relaxation parameter are also investigated by a series of experiments. A simulated dataset is used for testing the effectiveness of our motion compensation technique. The results demonstrate our reconstructed volume can eliminate undesirable artifacts like blurring. Our proposed method has potential to realize instantaneous presentation of 3D CT volume to physicians once the projection data are acquired.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, M.; Funk, L.P.; Sadeq, M.A.
1995-06-01
The major objective of this project was to formulate a Chunk Rubber Asphalt Concrete (CRAC) mix for use on low volume roads. CRAC is a rubber modified asphalt concrete product produced by the `dry process` where rubber chunks of 1/2 inch size are used as aggregate in a cold mix with a type C fly ash. The second objective of this project was to develop guidelines concerning the use of rubber modified asphalt concrete hot mix to include: (1) Design methods for use of asphalt-rubber mix for new construction and overlay, (2) Mix design method for asphalt-rubber, and (3) Testmore » method for determining the amount of rubber in an asphalt-rubber concrete for quality control purposes.« less
[Correction of posttraumatic thoracolumbar kyphosis with modified pedicle subtraction osteotomy].
Chen, Fei; Kang, Yijun; Zhou, Bin; Dai, Zhehao
2016-11-28
To evaluate the efficacy and safety of modified pedicle subtraction osteotomy for treatment of thoracolumbar old fracture with kyphosis. Methods: From January 2003 to January 2013, 58 patients of thoracolumbar kyphosis, who underwent modified pedicle subtraction osteotomy, were reviewed. Among them, 45 cases underwent initial operation and 13 cases underwent revision surgery. Preoperative and postoperative kyphotic Cobb's angle, score of back pain, as well as the incidence of complication were accessed by using visual analogue scale (VAS) and Oswestry disability index (ODI). Results: Mean follow-up duration was 42 months (range, 24-60 months). Average operative time was 258 min (range, 190-430 min), while average bleeding was 950 mL (range, 600-1 600 mL). All the patients were significantly improved in function and self-image, and achieved kyphosis correction with 17.9°± 4.3°. VAS of low back pain was decreased by 3.1±0.6; ODI was dropped by 25.3%±5.5%. 3 patients (5.2%) suffered anterior thigh numbness and got recovery after 3 months of follow-up. Complications happened in 19 patients, including 12 with cerebrospinal fluid leak, 4 with superficial wound infection, and 3 with urinary tract infection. All these complications were managed properly and none of them underwent reoperation. Conclusion: Modified pedicle subtraction osteotomy is a safe and effective technique for the treatment of old fracture with kyphosis.
Modified Hawking radiation in a BTZ black hole using Damour Ruffini method
NASA Astrophysics Data System (ADS)
He, Xiaokai; Liu, Wenbiao
2007-09-01
Considering energy conservation, angular momentum conservation, and the particles' back reaction to space-time, the scalar particles' Hawking radiation from a BTZ black hole was investigated using Damour-Ruffini method. The exact expression of the emission rate near the horizon is obtained and the result indicates that Hawking radiation spectrum is not purely thermal. The result obtained is consistent with the previous literatures. It is in agreement with an underlying unitary theory and offers a possible mechanism to explain the information loss paradox. Whereas, the method is more concise and understandable.
A Comparison of Ultrasound Tomography Methods in Circular Geometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leach, R R; Azevedo, S G; Berryman, J G
2002-01-24
Extremely high quality data was acquired using an experimental ultrasound scanner developed at Lawrence Livermore National Laboratory using a 2D ring geometry with up to 720 transmitter/receiver transducer positions. This unique geometry allows reflection and transmission modes and transmission imaging and quantification of a 3D volume using 2D slice data. Standard image reconstruction methods were applied to the data including straight-ray filtered back projection, reflection tomography, and diffraction tomography. Newer approaches were also tested such as full wave, full wave adjoint method, bent-ray filtered back projection, and full-aperture tomography. A variety of data sets were collected including a formalin-fixed humanmore » breast tissue sample, a commercial ultrasound complex breast phantom, and cylindrical objects with and without inclusions. The resulting reconstruction quality of the images ranges from poor to excellent. The method and results of this study are described including like-data reconstructions produced by different algorithms with side-by-side image comparisons. Comparisons to medical B-scan and x-ray CT scan images are also shown. Reconstruction methods with respect to image quality using resolution, noise, and quantitative accuracy, and computational efficiency metrics will also be discussed.« less
Tibbles, Anthony C; Waalen, Judith K; Hains, François C
1998-01-01
Background: The Oswestry Low Back Pain Disability Questionnaire (ODQ) is a widely used 10-item paper and pencil measure of disability resulting from low back pain. However, few studies have assessed the psychometric properties of the instrument. This study evaluated the response set bias, the internal consistency, and the construct validity of the ODQ. Objectives: The original ODQ was compared to seven modified versions to examine whether a response set bias existed. The internal consistency of the ODQ was assessed using the Cronbach alpha. Finally, the relationship between scores on the ODQ and the Roland Morris Functional Disability Scal (RM) was examined. Methods: Seven modified versions of the ODQ were developed from the original. One of the eight versions was randomly allocated to 102 adult patients presenting with low lack pain. There was no attempt to select patients on the basis of pain intensity or prior treatment so as to maximize the range and diversity of low back pain sufferers. Results: Results suggest that the responses given on the eight versions of the ODQ are a function of content and not of the format in which the items are presented. The ODQ also has strong internal consisstency (alpha = 0.85) and is strongly correlated to the RM (r = .70, p = .0005). The ODQ is a significant predictor of the RM scores (T-9.45, p = .0005) and duration of symptoms (T = -2.17, p = .0325). Conclusion: The ODQ appears to possess stable psychometric properties. The use of more than one version provides practitioners with a means of repeatedly assessing the disability levels of patients suffering from low back pain over the course of treatment.
Effectiveness of recycling light in ultra-bright short-arc discharge lamps.
Malul, Asher; Nakar, Doron; Feuermann, Daniel; Gordon, Jeffrey M
2007-10-17
Recycling light back into a plasma lamp's radiant zone can enhance its radiance. Measurements are reported for the effectiveness, spectral properties and modified plasma radiance maps that result from light recycling with a specular hemispherical mirror in commercial 150 W ultrabright Xenon short-arc discharge lamps, motivated by projection, biomedical and high-temperature furnace applications. For certain spectral windows and plasma arc regions, radiance can be heightened by up to 70%. However, the overall light recycling efficiency is reduced to about half this value due to lamp geometry. The manner in which light-plasma interactions affect light recycling efficacy is also elucidated.
ÇIÇEK, Ersan; KOÇAK, Mustafa Murat; KOÇAK, Sibel; SAĞLAM, Baran Can; TÜRKER, Sevinç Aktemur
2017-01-01
Abstract Postoperative pain is a frequent complication associated with root canal treatment, especially during apical instrumentation of tooth with preexisting periradicular inflammation Objectives The aim of this clinical study was to evaluate the influence of the instrumentation techniques on the incidence and intensity of postoperative pain in single-visit root canal treatment. Material and Methods Ninety patients with single root/canal and non-vital pulps were included. The patients were assigned into 3 groups according to root canal instrumentation technique used; modified step-back, reciprocal, and rotational techniques. Root canal treatment was carried out in a single visit and the severity of postoperative pain was assessed via 4-point pain intensity scale. All the participants were called through the phone at 12, 24 and 48 h to obtain the pain scores. Data were analyzed through the Kruskal–Wallis test. Results There was significant difference between all groups (p<0.05). The modified step-back technique produced postoperative pain significantly lower than the rotational (p=0.018) and reciprocal (p=0.020) techniques. No difference was found between the reciprocal and rotational techniques (p=0.868). Postoperative pain in the first 12 h period (p=0.763) and in the 24 h period (p=0.147) was not significantly different between the groups. However, the difference in the 48 h period was statistically different between the groups (p=0.040). Conclusion All instrumentation techniques caused postoperative pain. The modified step-back technique produced less pain compared to the rotational and reciprocal techniques. PMID:28198972
2006-01-01
on genetically modified (GM) seeds make this a crime (Shiva, 2005). Patents also appropriate the traditional use of products India’s Neem tree has...genetic engineering,” that apply across a range of industries. The methods are the same, whether manipulating organisms to clean up pollution or using ...back to 8000 BC when the Mesopotamian people used selective breeding practices to improve their livestock and to 6000 BC when the Sumerians began
A modified Dodge algorithm for the parabolized Navier-Stokes equations and compressible duct flows
NASA Technical Reports Server (NTRS)
Cooke, C. H.; Dwoyer, D. M.
1983-01-01
A revised version of Dodge's split-velocity method for numerical calculation of compressible duct flow has been developed. The revision incorporates balancing of massflow rates on each marching step in order to maintain front-to-back continuity during the calculation. Qualitative agreement with analytical predictions and experimental results has been obtained for some flows with well-known solutions.
Plenoptic projection fluorescence tomography.
Iglesias, Ignacio; Ripoll, Jorge
2014-09-22
A new method to obtain the three-dimensional localization of fluorochrome distributions in micrometric samples is presented. It uses a microlens array coupled to the image port of a standard microscope to obtain tomographic data by a filtered back-projection algorithm. Scanning of the microlens array is proposed to obtain a dense data set for reconstruction. Simulation and experimental results are shown and the implications of this approach in fast 3D imaging are discussed.
Optimization and Comparison of Different Digital Mammographic Tomosynthesis Reconstruction Methods
2007-04-01
physical measurements of impulse response analysis, modulation transfer function (MTF) and noise power spectrum (NPS). (Months 5- 12). 1.2.1. Simulate...added: projection images with simulated impulse and the 1/r2 shading difference. Other system blur and noise issues were not addressed in this paper...spectrum (NPS), Noise -equivalent quanta (NEQ), impulse response, Back Projection (BP) 1. INTRODUCTION Digital breast tomosynthesis is a new
Foot posture, foot function and low back pain: the Framingham Foot Study
Menz, Hylton B.; Dufour, Alyssa B.; Riskowski, Jody L.; Hillstrom, Howard J.
2013-01-01
Objective. Abnormal foot posture and function have been proposed as possible risk factors for low back pain, but this has not been examined in detail. The objective of this study was to explore the associations of foot posture and foot function with low back pain in 1930 members of the Framingham Study (2002–05). Methods. Low back pain, aching or stiffness on most days was documented on a body chart. Foot posture was categorized as normal, planus or cavus using static weight-bearing measurements of the arch index. Foot function was categorized as normal, pronated or supinated using the centre of pressure excursion index derived from dynamic foot pressure measurements. Sex-specific multivariate logistic regression models were used to examine the associations of foot posture, foot function and asymmetry with low back pain, adjusting for confounding variables. Results. Foot posture showed no association with low back pain. However, pronated foot function was associated with low back pain in women [odds ratio (OR) = 1.51, 95% CI 1.1, 2.07, P = 0.011] and this remained significant after adjusting for age, weight, smoking and depressive symptoms (OR = 1.48, 95% CI 1.07, 2.05, P = 0.018). Conclusion. These findings suggest that pronated foot function may contribute to low back symptoms in women. Interventions that modify foot function, such as orthoses, may therefore have a role in the prevention and treatment of low back pain. PMID:24049103
Impact of Electro-Magneto Concave Collector on the Characterizations of Electrospun Nanofibers
NASA Astrophysics Data System (ADS)
Shehata, Nader; Abdelkader, Mohamed
2018-05-01
We introduce a modified approach to produce aligned nanofibers through electro-magneto concave collectors. Both electric and magnetic fields distributions are simulated with COMSOL Multiphysics for different collectors including conventional, concave and modified concave collectors by adding magnetic discs in the back. Orientation matrices are evaluated for each collector in the study, and the highest degree of alignment is found to be with the modified concave collector with a percentage of 68%, followed by the concave collector with a percentage of 57%, which shows an improvement of the proposed method by adding a magnetic field. The generated nanofiber mats from the electro-magneto concave collector show improvements in both mechanical (Young's modulus = 117.66 MPa) and thermal properties compared to both concave and conventional collectors.
Study protocol title: a prospective cohort study of low back pain.
Garg, Arun; Hegmann, Kurt T; Moore, J Steven; Kapellusch, Jay; Thiese, Matthew S; Boda, Sruthi; Bhoyr, Parag; Bloswick, Donald; Merryweather, Andrew; Sesek, Richard; Deckow-Schaefer, Gwen; Foster, James; Wood, Eric; Sheng, Xiaoming; Holubkov, Richard
2013-03-07
Few prospective cohort studies of workplace low back pain (LBP) with quantified job physical exposure have been performed. There are few prospective epidemiological studies for LBP occupational risk factors and reported data generally have few adjustments for many personal and psychosocial factors. A multi-center prospective cohort study has been incepted to quantify risk factors for LBP and potentially develop improved methods for designing and analyzing jobs. Due to the subjectivity of LBP, six measures of LBP are captured: 1) any LBP, 2) LBP ≥ 5/10 pain rating, 3) LBP with medication use, 4) LBP with healthcare provider visits, 5) LBP necessitating modified work duties and 6) LBP with lost work time. Workers have thus far been enrolled from 30 different employment settings in 4 diverse US states and performed widely varying work. At baseline, workers undergo laptop-administered questionnaires, structured interviews, and two standardized physical examinations to ascertain demographics, medical history, psychosocial factors, hobbies and physical activities, and current musculoskeletal disorders. All workers' jobs are individually measured for physical factors and are videotaped. Workers are followed monthly for the development of low back pain. Changes in jobs necessitate re-measure and re-videotaping of job physical factors. The lifetime cumulative incidence of low back pain will also include those with a past history of low back pain. Incident cases will exclude prevalent cases at baseline. Statistical methods planned include survival analyses and logistic regression. Data analysis of a prospective cohort study of low back pain is underway and has successfully enrolled over 800 workers to date.
Modified Standard Penetration Test–based Drilled Shaft Design Method for Weak Rocks (Phase 2 Study)
DOT National Transportation Integrated Search
2017-12-15
In this project, Illinois-specific design procedures were developed for drilled shafts founded in weak shale or rock. In particular, a modified standard penetration test was developed and verified to characterize the in situ condition of weak shales ...
Prevalence of low back pain among handloom weavers in West Bengal, India
Durlov, Santu; Chakrabarty, Sabarni; Chatterjee, Arijit; Das, Tamal; Dev, Samrat; Gangopadhyay, Somnath; Haldar, Prasun; Maity, Santi Gopal; Sarkar, Krishnendu; Sahu, Subhashis
2014-01-01
Background: Handloom is one of the oldest industries in India, particularly in West Bengal, where a considerable number of rural people are engaged in weaving. Objectives: The purpose of this study was to evaluate the prevalence of low back pain among the handloom weavers in India. Methods: A modified Nordic Musculoskeletal Disorder Questionnaire and Oswestry Low Back Pain Disability Questionnaire along with a body part discomfort scale were administered to handloom weavers (n = 175). Working posture of the participants was assessed using the Ovako Working Posture Analysis System (OWAS). Results: Sixty eight per cent of the participants reported suffering from low back pain, making it the most prevalent disorder in our sample. Analysis of the Oswestry Low Back Pain Disability Questionnaire data revealed that among those with low back pain (n = 119), 2% had severe disabilities, 46% had moderate disabilities, and 52% had minimal disabilities. Statistical analyses revealed a positive significant association between the intensity of pain in the lower back and an increased number of years of work experience (P<0.05). Conclusions: The study underlines the need for further research regarding the postural strain of weavers and also suggests the implementation of ergonomic design into weaver workstations to minimize the adverse effect of their current working postures. Improving upon the weaver’s work-posture could improve their quality of life. PMID:25224808
Project Puffin: How We Brought Puffins Back to Egg Rock.
ERIC Educational Resources Information Center
Kress, Stephen W.; Salmansohn, Pete
This book describes Project Puffin, a project which aimed to bring puffins that have been threatened with local extinction back to the coast of Maine. The book describes puffins, how they adapted to their ocean environment, how they catch fish, socialize, nest in burrows, and raise their young. (JRH)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, F; Park, J; Barraclough, B
2016-06-15
Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end,more » tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.« less
Lisi, Anthony J; Salsbury, Stacie A; Hawk, Cheryl; Vining, Robert D; Wallace, Robert B; Branson, Richard; Long, Cynthia R; Burgo-Black, A Lucille; Goertz, Christine M
2018-02-01
The purpose of this study was to develop an integrated care pathway for doctors of chiropractic, primary care providers, and mental health professionals who manage veterans with low back pain, with or without mental health comorbidity, within Department of Veterans Affairs health care facilities. The research method used was a consensus process. A multidisciplinary investigative team reviewed clinical guidelines and Veterans Affairs pain and mental health initiatives to develop seed statements and care algorithms to guide chiropractic management and collaborative care of veterans with low back pain. A 5-member advisory committee approved initial recommendations. Veterans Affairs-based panelists (n = 58) evaluated the pathway via e-mail using a modified RAND/UCLA methodology. Consensus was defined as agreement by 80% of panelists. The modified Delphi process was conducted in July to December 2016. Most (93%) seed statements achieved consensus during the first round, with all statements reaching consensus after 2 rounds. The final care pathway addressed the topics of informed consent, clinical evaluation including history and examination, screening for red flags, documentation, diagnostic imaging, patient-reported outcomes, adverse event reporting, chiropractic treatment frequency and duration standards, tailored approaches to chiropractic care in veteran populations, and clinical presentation of common mental health conditions. Care algorithms outlined chiropractic case management and interprofessional collaboration and referrals between doctors of chiropractic and primary care and mental health providers. This study offers an integrative care pathway that includes chiropractic care for veterans with low back pain. Copyright © 2018. Published by Elsevier Inc.
Villafañe, Jorge H; Gobbo, Massimiliano; Peranzoni, Matteo; Naik, Ganesh; Imperio, Grace; Cleland, Joshua A; Negrini, Stefano
2016-09-01
This systematic literature review aimed at examining the validity and applicability in everyday clinical rehabilitation practise of methods for the assessment of back muscle fatiguability in patients with chronic non-specific low back pain (CNSLBP). Extensive research was performed in MEDLINE, Cumulative Index of Nursing and Allied Health Literature (CINAHL), Embase, Physiotherapy Evidence Database (PEDro) and Cochrane Central Register of Controlled Trials (CENTRAL) databases from their inception to September 2014. Potentially relevant articles were also manually looked for in the reference lists of the identified publications. Studies examining lumbar muscle fatigue in people with CNSLBP were selected. Two reviewers independently selected the articles, carried out the study quality assessment and extracted the results. A modified Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) scale was used to evaluate the scientific rigour of the selected works. Twenty-four studies fulfilled the selection criteria and were included in the systematic review. We found conflicting data regarding the validity of methods used to examine back muscle fatigue. The Biering-Sorensen test, performed in conjunction with surface electromyography spectral analysis, turned out to be the most widely used and comparatively, the most optimal modality currently available to assess objective back muscle fatigue in daily clinical practise, even though critical limitations are discussed. Future research should address the identification of an advanced method for lower back fatigue assessment in patients with CNSLBP which, eventually, might provide physical therapists with an objective and reliable test usable in everyday clinical practise. Implications for Rehabilitation Despite its limitations, the Biering-Sorensen test is currently the most used, convenient and easily available fatiguing test for lumbar muscles. To increase validity and reliability of the Biering-Sorensen test, concomitant activation of synergistic muscles should be taken into account. Pooled mean frequency and half-width of the spectrum are currently the most valid electromyographic parameters to assess fatigue in chronic non-specific low back pain. Body mass index, grading of pain and level of disability of the study population should be reported to enhance research quality.
Biological risk indicators for recurrent non-specific low back pain in adolescents.
Jones, M A; Stratton, G; Reilly, T; Unnithan, V B
2005-03-01
A matched case-control study was carried out to evaluate biological risk indicators for recurrent non-specific low back pain in adolescents. Adolescents with recurrent non-specific low back pain (symptomatic; n = 28; mean (SD) age 14.9 (0.7) years) and matched controls (asymptomatic; n = 28; age 14.9 (0.7) years) with no history of non-specific low back pain participated. Measures of stature, mass, sitting height, sexual maturity (Tanner self assessment), lateral flexion of the spine, lumbar sagittal plane mobility (modified Schober), hip range of motion (Leighton flexometer), back and hamstring flexibility (sit and reach), and trunk muscle endurance (number of sit ups) were performed using standardised procedures with established reliability. Backward stepwise logistic regression analysis was performed, with the presence/absence of recurrent low back pain as the dependent variable and the biological measures as the independent variables. Hip range of motion, trunk muscle endurance, lumbar sagittal plane mobility, and lateral flexion of the spine were identified as significant risk indicators of recurrent low back pain (p<0.05). Follow up analysis indicated that symptomatic subjects had significantly reduced lateral flexion of the spine, lumbar sagittal plane mobility, and trunk muscle endurance (p<0.05). Hip range of motion, abdominal muscle endurance, lumbar flexibility, and lateral flexion of the spine were risk indicators for recurrent non-specific low back pain in a group of adolescents. These risk indicators identify the potential for exercise as a primary or secondary prevention method.
Putting America Back to Work: The Kellogg Leadership Initiative. A Report and Guidebook.
ERIC Educational Resources Information Center
American Association of Community and Junior Colleges, Washington, DC.
As part of the American Association of Community and Junior Colleges' Putting America Back to Work Project, this monograph examines the economic climate of the United States and the role of the community colleges in economic recovery. The first sections outline the origins and initial activities of the Putting America Back to Work Project, which…
An Earth Orbiting Satellite Service and Repair Facility
NASA Technical Reports Server (NTRS)
Berndt, Andrew; Cardoza, Mike; Chen, John; Daley, Gunter; Frizzell, Andy; Linton, Richard; Rast, Wayne
1989-01-01
A conceptual design was produced for the Geosynchronous Satellite Servicing Platform (GSSP), an orbital facility capable of repairing and servicing satellites in geosynchronous orbit. The GSSP is a man-tended platform, which consists of a habitation module, operations module, service bay and truss assembly. This design review includes an analysis of life support systems, thermal and power requirements, robotic and automated systems, control methods and navigation, and communications systems. The GSSP will utilize existing technology available at the time of construction, focusing mainly on modifying and integrating existing systems. The entire facility, along with two satellite retrieval vehicles (SRV), will be placed in geosynchronous orbit by the Advanced Launch System. The SRV will be used to ferry satellites to and from the GSSP. Technicians will be transferred from Earth to the GSSP and back in an Apollo-derived Crew Transfer Capsule (CTC). These missions will use advanced telerobotic equipment to inspect and service satellites. Four of these missions are tentatively scheduled per year. At this rate, the GSSP will service over 650 satelites during the projected 25 year lifespan.
AbouHassan, J; Milosavljevic, S; Carman, A
2010-12-01
As stooped postures are known to increase kinematic and kinetic loading on the lumbar spine they can be problematic for people with low back pain and postural task modification is often recommended. For the Muslim with low back pain, the bowing postures during prayer can aggravate low back symptoms. The aims of this study were to describe lumbo-sacral and pelvic tilt kinematics and lumbo-sacral kinetics during the standard bowing postures of Islam and to compare these to kinematic and kinetic data gathered during a clinically recommended modified bowing posture. The study was a repeated measures within subject cross-over design with 33 healthy male Muslim participants. 3-D motion analysis data were gathered to calculate body joint angles during the two bowing postures. A 3-D biomechanical model was then used to calculate spinal loads. Paired t-test analyses showed that the use of the modified posture resulted in significantly less pelvic tilt range of motion and anterior shear force and compressive force L5/S1, at stages 1 and 5 of bowing. Although this study was conducted with healthy young Muslim males, the use of this modified bent knee posture is recommended for all Muslims with low back pain. Clinical trials are being considered to determine the clinical utility of this postural manoeuvre as an intervention. STATEMENT OF RELEVANCE: The presence of low back pain may hinder a Muslim's ability to use the traditional Islamic bowing posture. Muslims who have low back pain may benefit from adopting a modification to the traditional bowing posture, which has been found to reduce the loads and postural demands on the lower back.
Golf-Related Low Back Pain: A Review of Causative Factors and Prevention Strategies
Lindsay, David M.; Vandervoort, Anthony A.
2014-01-01
Golf is a popular sport with both perceived and real health benefits. However, certain injury risks are also prevalent, particularly to the lower back. Epidemiological studies have shown that lower back pain (LBP) from golf account for between 18% and 54% of all documented ailments, leading many researchers to regard the condition as the most common golf injury. The purpose of this review was to examine the scientific literature to ascertain the risk factors associated with the development of LBP from playing golf and suggest methods to modify or limit these factors. Results of the review indicate that the high frequency of LBP appears multi-factorial although the asymmetrical and forceful nature of the swing along with excessive play and practice, particularly amongst elite players, appear to be common factors. Other factors include swing flaws leading to excessive side-bend and over-rotation of the spine, abnormal muscle recruitment, poor trunk endurance, restricted lead hip internal rotation and the use of unnecessarily stressful club transportation methods. Methods to help control or eliminate excessive stress on the lower back would include reducing the amount spent playing or practicing, seeking professional assistance to assess and adjust swing mechanics, improve trunk and hip flexibility, increase the strength and endurance of the trunk musculature, consider different footwear options and avoid carrying the golf bag. Adopting some or all of these recommendations should allow players to continue to enjoy the sport of golf well into their senior years. PMID:25741420
NASA Astrophysics Data System (ADS)
Sun, Benyuan; Yue, Shihong; Cui, Ziqiang; Wang, Huaxiang
2015-12-01
As an advanced measurement technique of non-radiant, non-intrusive, rapid response, and low cost, the electrical tomography (ET) technique has developed rapidly in recent decades. The ET imaging algorithm plays an important role in the ET imaging process. Linear back projection (LBP) is the most used ET algorithm due to its advantages of dynamic imaging process, real-time response, and easy realization. But the LBP algorithm is of low spatial resolution due to the natural ‘soft field’ effect and ‘ill-posed solution’ problems; thus its applicable ranges are greatly limited. In this paper, an original data decomposition method is proposed, and every ET measuring data are decomposed into two independent new data based on the positive and negative sensing areas of the measuring data. Consequently, the number of total measuring data is extended to twice as many as the number of the original data, thus effectively reducing the ‘ill-posed solution’. On the other hand, an index to measure the ‘soft field’ effect is proposed. The index shows that the decomposed data can distinguish between different contributions of various units (pixels) for any ET measuring data, and can efficiently reduce the ‘soft field’ effect of the ET imaging process. In light of the data decomposition method, a new linear back projection algorithm is proposed to improve the spatial resolution of the ET image. A series of simulations and experiments are applied to validate the proposed algorithm by the real-time performances and the progress of spatial resolutions.
Buendía, Mateo; Cibrián, Rosa M.; Salvador, Rosario; Laguía, Manuel; Martín, Antonio; Gomar, Francisco
2006-01-01
New noninvasive techniques, amongst them structured light methods, have been applied to study rachis deformities, providing a way to evaluate external back deformities in the three planes of space. These methods are aimed at reducing the number of radiographic examinations necessary to diagnose and follow-up patients with scoliosis. By projecting a grid over the patient’s back, the corresponding software for image treatment provides a topography of the back in a color or gray scale. Visual inspection of back topographic images using this method immediately provides information about back deformity, but it is important to determine quantifier variables of the deformity to establish diagnostic criteria. In this paper, two topographic variables [deformity in the axial plane index (DAPI) and posterior trunk symmetry index (POTSI)] that quantify deformity in two different planes are analyzed. Although other authors have reported the POTSI variable, the DAPI variable proposed in this paper is innovative. The upper normality limit of these variables in a nonpathological group was determined. These two variables have different and complementary diagnostic characteristics, therefore we devised a combined diagnostic criterion: cases with normal DAPI and POTSI (DAPI ≤ 3.9% and POTSI ≤ 27.5%) were diagnosed as nonpathologic, but cases with high DAPI or POTSI were diagnosed as pathologic. When we used this criterion to analyze all the cases in the sample (56 nonpathologic and 30 with idiopathic scoliosis), we obtained 76.6% sensitivity, 91% specificity, and a positive predictive value of 82%. The interobserver, intraobserver, and interassay variability were studied by determining the variation coefficient. There was good correlation between topographic variables (DAPI and POTSI) and clinical variables (Cobb’s angle and vertebral rotation angle). PMID:16609858
Explosion localization and characterization via infrasound using numerical modeling
NASA Astrophysics Data System (ADS)
Fee, D.; Kim, K.; Iezzi, A. M.; Matoza, R. S.; Jolly, A. D.; De Angelis, S.; Diaz Moreno, A.; Szuberla, C.
2017-12-01
Numerous methods have been applied to locate, detect, and characterize volcanic and anthropogenic explosions using infrasound. Far-field localization techniques typically use back-azimuths from multiple arrays (triangulation) or Reverse Time Migration (RTM, or back-projection). At closer ranges, networks surrounding a source may use Time Difference of Arrival (TDOA), semblance, station-pair double difference, etc. However, at volcanoes and regions with topography or obstructions that block the direct path of sound, recent studies have shown that numerical modeling is necessary to provide an accurate source location. A heterogeneous and moving atmosphere (winds) may also affect the location. The time reversal mirror (TRM) application of Kim et al. (2015) back-propagates the wavefield using a Finite Difference Time Domain (FDTD) algorithm, with the source corresponding to the location of peak convergence. Although it provides high-resolution source localization and can account for complex wave propagation, TRM is computationally expensive and limited to individual events. Here we present a new technique, termed RTM-FDTD, which integrates TRM and FDTD. Travel time and transmission loss information is computed from each station to the entire potential source grid from 3-D Green's functions derived via FDTD. The wave energy is then back-projected and stacked at each grid point, with the maximum corresponding to the likely source. We apply our method to detect and characterize thousands of explosions from Yasur Volcano, Vanuatu and Etna Volcano, Italy, which both provide complex wave propagation and multiple source locations. We compare our results with those from more traditional methods (e.g. semblance), and suggest our method is preferred as it is computationally less expensive than TRM but still integrates numerical modeling. RTM-FDTD could be applied to volcanic other anthropogenic sources at a wide variety of ranges and scenarios. Kim, K., Lees, J.M., 2015. Imaging volcanic infrasound sources using time reversal mirror algorithm. Geophysical Journal International 202, 1663-1676.
Foo, Ning-Ping; Chang, Jer-Hao; Su, Shih-Bin; Chen, Kow-Tong; Cheng, Ching-Fa; Chen, Pei-Chung
2014-01-01
Background The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). Purpose To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. Methods Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. Results The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. Conclusions The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain. PMID:25329643
Marion, Bill; Smith, Benjamin
2017-03-27
Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. Here, a method was developed to back-solve for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the measured ac power of south-facing PV module/micro-inverter systems. The method was validated using one year of irradiance and PV performance measurements for five PV systems, each with a different tilt/azimuth orientation, and located in Golden, Colorado. Compared to using a measured global horizontal irradiance for PV performance model input,more » using the back-solved values of DNI and DHI only increased the range of mean bias deviations from measured values by 0.6% for the modeled annual averages of the global tilt irradiance and ac power for the five PV systems. Correcting for angle-of-incidence effects is an important feature of the method to prevent underestimating the solar resource and for modeling the performance of PV systems with more dissimilar PV module orientations. The results for the method were also shown more favorable than the results when using an existing power projection method for estimating the ac power.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, Bill; Smith, Benjamin
Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. Here, a method was developed to back-solve for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the measured ac power of south-facing PV module/micro-inverter systems. The method was validated using one year of irradiance and PV performance measurements for five PV systems, each with a different tilt/azimuth orientation, and located in Golden, Colorado. Compared to using a measured global horizontal irradiance for PV performance model input,more » using the back-solved values of DNI and DHI only increased the range of mean bias deviations from measured values by 0.6% for the modeled annual averages of the global tilt irradiance and ac power for the five PV systems. Correcting for angle-of-incidence effects is an important feature of the method to prevent underestimating the solar resource and for modeling the performance of PV systems with more dissimilar PV module orientations. The results for the method were also shown more favorable than the results when using an existing power projection method for estimating the ac power.« less
Evaluation of intrinsic respiratory signal determination methods for 4D CBCT adapted for mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Rachael; Pan, Tinsu, E-mail: tpan@mdanderson.org; Rubinstein, Ashley
Purpose: 4D CT imaging in mice is important in a variety of areas including studies of lung function and tumor motion. A necessary step in 4D imaging is obtaining a respiratory signal, which can be done through an external system or intrinsically through the projection images. A number of methods have been developed that can successfully determine the respiratory signal from cone-beam projection images of humans, however only a few have been utilized in a preclinical setting and most of these rely on step-and-shoot style imaging. The purpose of this work is to assess and make adaptions of several successfulmore » methods developed for humans for an image-guided preclinical radiation therapy system. Methods: Respiratory signals were determined from the projection images of free-breathing mice scanned on the X-RAD system using four methods: the so-called Amsterdam shroud method, a method based on the phase of the Fourier transform, a pixel intensity method, and a center of mass method. The Amsterdam shroud method was modified so the sharp inspiration peaks associated with anesthetized mouse breathing could be detected. Respiratory signals were used to sort projections into phase bins and 4D images were reconstructed. Error and standard deviation in the assignment of phase bins for the four methods compared to a manual method considered to be ground truth were calculated for a range of region of interest (ROI) sizes. Qualitative comparisons were additionally made between the 4D images obtained using each of the methods and the manual method. Results: 4D images were successfully created for all mice with each of the respiratory signal extraction methods. Only minimal qualitative differences were noted between each of the methods and the manual method. The average error (and standard deviation) in phase bin assignment was 0.24 ± 0.08 (0.49 ± 0.11) phase bins for the Fourier transform method, 0.09 ± 0.03 (0.31 ± 0.08) phase bins for the modified Amsterdam shroud method, 0.09 ± 0.02 (0.33 ± 0.07) phase bins for the intensity method, and 0.37 ± 0.10 (0.57 ± 0.08) phase bins for the center of mass method. Little dependence on ROI size was noted for the modified Amsterdam shroud and intensity methods while the Fourier transform and center of mass methods showed a noticeable dependence on the ROI size. Conclusions: The modified Amsterdam shroud, Fourier transform, and intensity respiratory signal methods are sufficiently accurate to be used for 4D imaging on the X-RAD system and show improvement over the existing center of mass method. The intensity and modified Amsterdam shroud methods are recommended due to their high accuracy and low dependence on ROI size.« less
DOT National Transportation Integrated Search
2003-06-01
It is estimated that approximately 8,500 abandoned underground mines are present in Ohio and mine-related : subsidence has been a problem dating back to the 1920's. Many investigative methods have been utilized with : varying degrees of success in an...
Zha, Kan; Busch, Stephen; Park, Cheolwoong; ...
2016-06-24
In-cylinder flow measurements are necessary to gain a fundamental understanding of swirl-supported, light-duty Diesel engine processes for high thermal efficiency and low emissions. Planar particle image velocimetry (PIV) can be used for non-intrusive, in situ measurement of swirl-plane velocity fields through a transparent piston. In order to keep the flow unchanged from all-metal engine operation, the geometry of the transparent piston must adapt the production-intent metal piston geometry. As a result, a temporally- and spatially-variant optical distortion is introduced to the particle images. Here, to ensure reliable measurement of particle displacements, this work documents a systematic exploration of optical distortionmore » quantification and a hybrid back-projection procedure that combines ray-tracing-based geometric and in situ manual back-projection approaches.« less
2003-08-25
NASA's F-15B research testbed jet from NASA's Dryden Flight Research Center flew in the supersonic shockwave of a Northrop Grumman Corp. modified U.S. Navy F-5E jet in support of the Shaped Sonic Boom Demonstration (SSBD) project, which is part of the DARPA's Quiet Supersonic Platform (QSP) program. On Aug. 27, 2003, the F-5 SSBD aircraft demonstrated a method to reduce the intensity of sonic booms.
Validity of the modified back-saver sit-and-reach test: a comparison with other protocols.
Hui, S S; Yuen, P Y
2000-09-01
Studies have shown that the classical sit-and-reach (CSR) test, the modified sit-and-reach (MSR), and the newly developed back-saver sit-and-reach (BS) test have poor criterion-related validity in estimating low-back flexibility but yielded moderate criterion-related validity in hamstring flexibility. The V sit-and-reach (VSR) test was found to be practical but the validity has not been established. The purpose of this study was to propose a modified back-saver sit-and-reach (MBS) test, which incorporated all advantages of the various protocols, and to compare the criterion-related validity and reliability of all these tests. 158 college students (F = 96, and M = 62; age = 20.77 +/- 2.51) performed CSR, VSR, BS (left and right leg), and MBS (left and right leg) tests in a randomized order. Scores from each test were then correlated with the criterion measures. For all sit-reach tests, intraclass reliability (single trial) was very high (r = 0.89-0.98). MBS yielded significant and highest r with low-back and hamstring criterion for men (r = 0.47-0.67) and women (r = 0.23-0.54). The low-back and right hamstring validity of MBS for men were significantly (P < 0.01) higher than those from BS and CSR, whereas no differences in criterion-related validity were found between the MBS and other protocols in women. The ratings of perceived comfort among the sit-and-reach protocols were significantly different (P < 0.001) from each other. The rating for MBS was observed the most comfortable test as compared with other protocols. The MBS test is not only a reliable test for hamstring and low-back flexibility, it is also a more practical with improved validity for hamstring and low-back flexibility in men than previous protocols.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-12
... multiple Issuer MBS is structured so that small issuers, who do not meet the minimum number of loans and... program, securities are backed by single-family or multifamily loans. Under the Ginnie Mae II program, securities are only backed by single family loans. Both the Ginnie Mae I and II MBS are modified pass-through...
Valenzuela-Pascual, Fran; Molina, Fidel; Corbi, Francisco; Blanco-Blanco, Joan; Gil, Rosa M; Soler-Gonzalez, Jorge
2015-11-23
Low back pain is the highest reported musculoskeletal problem worldwide. Up to 90 % of patients with low back pain have no clear explanation for the source and origin of their pain. These individuals commonly receive a diagnosis of non-specific low back pain. Patient education is a way to provide information and advice aimed at changing patients' cognition and knowledge about their chronic state through the reduction of fear of anticipatory outcomes and the resumption of normal activities. Information technology and the expedited communication processes associated with this technology can be used to deliver health care information to patients. Hence, this technology and its ability to deliver life-changing information has grown as a powerful and alternative health promotion tool. Several studies have demonstrated that websites can change and improve chronic patients' knowledge and have a positive impact on patients' attitudes and behaviors. The aim of this project is to identify chronic low back pain patients' beliefs about the origin and meaning of pain to develop a web-based educational tool using different educational formats and gamification techniques. This study has a mixed-method sequential exploratory design. The participants are chronic low back pain patients between 18-65 years of age who are attending a primary care setting. For the qualitative phase, subjects will be contacted by their family physician and invited to participate in a personal semi-structured interview. The quantitative phase will be a randomized controlled trial. Subjects will be randomly allocated using a simple random sample technique. The intervention group will be provided access to the web site where they will find information related to their chronic low back pain. This information will be provided in different formats. All of this material will be based on the information obtained in the qualitative phase. The control group will follow conventional treatment provided by their family physician. The main outcome of this project is to identify chronic low back pain patients' beliefs about the origin and meaning of pain to develop a web-based educational tool using different educational formats and gamification techniques. ClinicalTrials.gov NCT02369120 Date: 02/20/2015.
Kachanathu, Shaji John; Alenazi, Aqeel M; Seif, Hamada Eid; Hafez, Ashraf Ramadan; Alroumim, Meshari Abdulmohsen
2014-08-01
[Purpose] Nonspecific low back pain (NSLBP) is a very common but largely self-limiting condition. Several types of tape and their associated application methods are available for different conditions. The aim of the present study was to observe the effect of Kinesio taping (KT) compared with traditional management of NSLBP. [Subjects and Methods] Forty male and female patients with a mean age of 34.8±7.54 years were randomly divided into two groups; group 1 (n=20) which underwent conventional physical therapy with KT, and group 2 (n=20), which underwent only conventional physical therapy. The intervention sessions for both groups were three times per week for four weeks. Outcomes were assessed for activities of daily living (ADL) using the Roland-Morris Disability Questionnaire, pain severity using a visual analogue scale, and ranges of motion (ROMs) of trunk flexion and extension using the modified Schober's test. [Results] Significant differences in measures of pain, ADL, and trunk flexion and extension ROMs were observed post intervention within each group. In comparison, there were no significant differences in measures of pain, ADL, and trunk flexion and extension ROMs post intervention between groups. [Conclusion] A physical therapy program involving strengthening exercises for abdominal muscles and stretching exercises for back, hamstring, and iliopsoas muscles with or without Kinesio taping was beneficial in the treatment of chronic low back pain.
Koszela, Kamil; Krukowska, Sylwia; Woldańska-Okońska, Marta
2017-06-23
Back disorders are very common phenomena in modern society. One of the methods of spinal pain treatment is performing surgery. Unfortunately, this method is not one hundred percent effective. Some patients show no improvement after surgery, the pain persists and even increases. In these cases, it is reasonable to use the term Failed Back Surgery Syndrome (FBSS), i.e. back pain syndrome after unsuccessful spine surgery. The aim of the study is to assess the impact of rehabilitation on the pain intensity level in patients with FBSS. The study was conducted in a group of 38 patients aged from 32 to 87 (mean age 61 years), including 20 women and 18 men. All patients were operated for spinal pain syndrome. Afterwards, they underwent rehabilitation because of persisting pain after the surgery. For the pain assessment was used The Visual- Analogue Scale and The Laitinen Modified Questionnaire Indicators of Pain. The results were statistically analyzed. The study showed the high efficacy of specialized rehabilitation in patients with FBSS. The rehabilitation in patients with FBSS has a significant analgesic effect. Rehabilitation should be a gold standard in patients with FBSS.
Chau, P; Yip, P
2003-01-01
Objective: To estimate the infection curve of severe acute respiratory syndrome (SARS) using the back projection method and to assess the effectiveness of interventions. Design: Statistical method. Data: The daily reported number of SARS and interventions taken by Hong Kong Special Administrative Region (HKSAR) up to 24 June 2003 are used. Method: To use a back projection technique to construct the infection curve of SARS in Hong Kong. The estimated epidemic curve is studied to identify the major events and to assess the effectiveness of interventions over the course of the epidemic. Results: The SARS infection curve in Hong Kong is constructed for the period 1 March 2003 to 24 June 2003. Some interventions seem to be effective while others apparently have little or no effect. The infections among the medical and health workers are high. Conclusions: Quarantine of the close contacts of confirmed and suspected SARS cases seems to be the most effective intervention against spread of SARS in the community. Thorough disinfection of the infected area against environmental hazards is helpful. Infections within hospitals can be reduced by better isolation measures and protective equipments. PMID:14573569
Support of the eight-foot high-temperature tunnel modifications project
NASA Technical Reports Server (NTRS)
Hodges, Donald Y.; Shebalin, John V.
1987-01-01
An ultrasonic level sensor was developed to measure the liquid level in a storage vessel under high pressures, namely up to 6000 psi. The sensor is described. A prototype sensor was installed in the cooling-water storage vessel of the Eight-Foot High-Temperature Tunnel. Plans are being made to install the readout instrument in the control room, so that tunnel operators can monitor the water level during the course of a tunnel run. It was discovered that the sensor will operate at cryogenic temperatures. Consequently, a sensor will be installed in the modified Eight-Foot High-Temperature Tunnel to measure the sound speed of liquid oxygen (LOX) as it is transferred from a storage vessel to the tunnel combustor at pressure of about 3000 psi. The sound speed is known to be a reliable indicator of contamination of LOX by pressurized gaseous nitrogen, which will be used to effect the transfer. Subjecting the sensor to a temperature cycle from room temperature to liquid nitrogen temperature and back again several times revealed no deterioration in sensor performance. The method using this sensor is superior to the original method, which was to bleed samples of LOX from the storage vessel to an independent chamber for measurement of the sound speed.
DOT National Transportation Integrated Search
2011-08-01
The Backing crash Countermeasures project, part of the U.S. Department of Transportation's Advanced Crash Avoidance Technologies (ACAT) program, developed a basic methodological framework and computerbased simulation model to estimate the effectiv...
How Engineers Engineer: Lessons from My First Big Engineering Project
ERIC Educational Resources Information Center
Roman, Harry T.
2008-01-01
Little did the author realize how much his first engineering project would change his career path, but when it came, he was hooked forever on doing R&D-type engineering. In this article, the author takes the reader back to his first really important electrical engineering project. While the technology he worked on back then is antiquated by…
ERIC Educational Resources Information Center
Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean
2015-01-01
Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…
Solid-state NMR imaging system
Gopalsami, Nachappa; Dieckman, Stephen L.; Ellingson, William A.
1992-01-01
An apparatus for use with a solid-state NMR spectrometer includes a special imaging probe with linear, high-field strength gradient fields and high-power broadband RF coils using a back projection method for data acquisition and image reconstruction, and a real-time pulse programmer adaptable for use by a conventional computer for complex high speed pulse sequences.
2013-01-01
A new approach, the projective system approach, is proposed to realize modified projective synchronization between two different chaotic systems. By simple analysis of trajectories in the phase space, a projective system of the original chaotic systems is obtained to replace the errors system to judge the occurrence of modified projective synchronization. Theoretical analysis and numerical simulations show that, although the projective system may not be unique, modified projective synchronization can be achieved provided that the origin of any of projective systems is asymptotically stable. Furthermore, an example is presented to illustrate that even a necessary and sufficient condition for modified projective synchronization can be derived by using the projective system approach. PMID:24187522
Baradaran, Aslan; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2016-04-01
Prospective study. We aimed to validate the Persian version of the modified Oswestry disability questionnaire (MODQ) in patients with low back pain. Modified Oswestry low back pain disability questionnaire is a well-known condition-specific outcome measure that helps quantify disability in patients with lumbar syndromes. To test the validity in a pilot study, the Persian MODQ was administered to 25 individuals with low back pain. We then enrolled 200 consecutive patients with low back pain to fill the Persian MODQ as well as the short form 36 (SF-36) questionnaire. Convergent validity of the MODQ was tested using the Spearman's correlation coefficient between the MODQ and SF-36 subscales. Intraclass correlation coefficient (ICC) and Cronbach's α coefficient were measured to test the reliability between test and retest and internal consistency of all items, respectively. ICC for individual items ranged from 0.43 to 0.80 showing good reliability and reproducibility of each individual item. Cronbach's α coefficient was 0.69 showing good internal consistency across all 10 items of the Persian MODQ. Total MODQ score showed moderate to strong correlation with the eight subscales and the two domains of the SF-36. The highest correlation was between the MODQ and the physical functioning subscale of the SF-36 (r=-0.54, p<0.001) and the physical component domain of the SF-36 (r=-0.55, p<0.001) showing that MODQ is measuring what it is supposed to measure in terms of disability and physical function. Persian version of the MODQ is a valid and reliable tool for the assessment of the disability following low back pain.
NASA Astrophysics Data System (ADS)
Li, Qin; Berman, Benjamin P.; Schumacher, Justin; Liang, Yongguang; Gavrielides, Marios A.; Yang, Hao; Zhao, Binsheng; Petrick, Nicholas
2017-03-01
Tumor volume measured from computed tomography images is considered a biomarker for disease progression or treatment response. The estimation of the tumor volume depends on the imaging system parameters selected, as well as lesion characteristics. In this study, we examined how different image reconstruction methods affect the measurement of lesions in an anthropomorphic liver phantom with a non-uniform background. Iterative statistics-based and model-based reconstructions, as well as filtered back-projection, were evaluated and compared in this study. Statistics-based and filtered back-projection yielded similar estimation performance, while model-based yielded higher precision but lower accuracy in the case of small lesions. Iterative reconstructions exhibited higher signal-to-noise ratio but slightly lower contrast of the lesion relative to the background. A better understanding of lesion volumetry performance as a function of acquisition parameters and lesion characteristics can lead to its incorporation as a routine sizing tool.
Projections of suitable habitat for rare species under global warming scenarios
F. Thomas Ledig; Gerald E. Rehfeldt; Cuauhtemoc Saenz-Romero; Flores-Lopez Celestino
2010-01-01
Premise of the study: Modeling the contemporary and future climate niche for rare plants is a major hurdle in conservation, yet such projections are necessary to prevent extinctions that may result from climate change. Methods: We used recently developed spline climatic models and modifi ed Random Forests...
A label distance maximum-based classifier for multi-label learning.
Liu, Xiaoli; Bao, Hang; Zhao, Dazhe; Cao, Peng
2015-01-01
Multi-label classification is useful in many bioinformatics tasks such as gene function prediction and protein site localization. This paper presents an improved neural network algorithm, Max Label Distance Back Propagation Algorithm for Multi-Label Classification. The method was formulated by modifying the total error function of the standard BP by adding a penalty term, which was realized by maximizing the distance between the positive and negative labels. Extensive experiments were conducted to compare this method against state-of-the-art multi-label methods on three popular bioinformatic benchmark datasets. The results illustrated that this proposed method is more effective for bioinformatic multi-label classification compared to commonly used techniques.
A Comparison of Wood Density between Classical Cremonese and Modern Violins
Stoel, Berend C.; Borman, Terry M.
2008-01-01
Classical violins created by Cremonese masters, such as Antonio Stradivari and Giuseppe Guarneri Del Gesu, have become the benchmark to which the sound of all violins are compared in terms of their abilities of expressiveness and projection. By general consensus, no luthier since that time has been able to replicate the sound quality of these classical instruments. The vibration and sound radiation characteristics of a violin are determined by an instrument's geometry and the material properties of the wood. New test methods allow the non-destructive examination of one of the key material properties, the wood density, at the growth ring level of detail. The densities of five classical and eight modern violins were compared, using computed tomography and specially developed image-processing software. No significant differences were found between the median densities of the modern and the antique violins, however the density difference between wood grains of early and late growth was significantly smaller in the classical Cremonese violins compared with modern violins, in both the top (Spruce) and back (Maple) plates (p = 0.028 and 0.008, respectively). The mean density differential (SE) of the top plates of the modern and classical violins was 274 (26.6) and 183 (11.7) gram/liter. For the back plates, the values were 128 (2.6) and 115 (2.0) gram/liter. These differences in density differentials may reflect similar changes in stiffness distributions, which could directly impact vibrational efficacy or indirectly modify sound radiation via altered damping characteristics. Either of these mechanisms may help explain the acoustical differences between the classical and modern violins. PMID:18596937
Controlled differential pressure system for an enhanced fluid blending apparatus
Hallman, Jr., Russell Louis
2009-02-24
A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.
Back-Projection Cortical Potential Imaging: Theory and Results.
Haor, Dror; Shavit, Reuven; Shapiro, Moshe; Geva, Amir B
2017-07-01
Electroencephalography (EEG) is the single brain monitoring technique that is non-invasive, portable, passive, exhibits high-temporal resolution, and gives a directmeasurement of the scalp electrical potential. Amajor disadvantage of the EEG is its low-spatial resolution, which is the result of the low-conductive skull that "smears" the currents coming from within the brain. Recording brain activity with both high temporal and spatial resolution is crucial for the localization of confined brain activations and the study of brainmechanismfunctionality, whichis then followed by diagnosis of brain-related diseases. In this paper, a new cortical potential imaging (CPI) method is presented. The new method gives an estimation of the electrical activity on the cortex surface and thus removes the "smearing effect" caused by the skull. The scalp potentials are back-projected CPI (BP-CPI) onto the cortex surface by building a well-posed problem to the Laplace equation that is solved by means of the finite elements method on a realistic head model. A unique solution to the CPI problem is obtained by introducing a cortical normal current estimation technique. The technique is based on the same mechanism used in the well-known surface Laplacian calculation, followed by a scalp-cortex back-projection routine. The BP-CPI passed four stages of validation, including validation on spherical and realistic head models, probabilistic analysis (Monte Carlo simulation), and noise sensitivity tests. In addition, the BP-CPI was compared with the minimum norm estimate CPI approach and found superior for multi-source cortical potential distributions with very good estimation results (CC >0.97) on a realistic head model in the regions of interest, for two representative cases. The BP-CPI can be easily incorporated in different monitoring tools and help researchers by maintaining an accurate estimation for the cortical potential of ongoing or event-related potentials in order to have better neurological inferences from the EEG.
2013-01-01
Background Low back pain is a relevant public health problem, being an important cause of work absenteeism worldwide, as well as affecting the quality of life of sufferers and their individual functional performances. Supervised active physical routines and of cognitive-behavioral therapies are recommended for the treatment of chronic Low back pain, although evidence to support the effectiveness of different techniques is missing. Accordingly, the aim of this study is to contrast the effectiveness of two types of exercises, graded activity or supervised, in decreasing symptoms of chronic low back pain. Methods/design Sample will consist of 66 patients, blindly allocated into one of two groups: 1) Graded activity which, based on an operant approach, will use time-contingent methods aiming to increase participants’ activity levels; 2) Supervised exercise, where participants will be trained for strengthening, stretching, and motor control targeting different muscle groups. Interventions will last one hour, and will happen twice a week for 6 weeks. Outcomes (pain, disability, quality of life, global perceived effect, return to work, physical activity, physical capacity, and kinesiophobia) will be assessed at baseline, at treatment end, and three and six months after treatment end. Data collection will be conducted by an investigator blinded to treatment allocation. Discussion This project describes the randomisation method that will be used to compare the effectiveness of two different treatments for chronic low back pain: graded activity and supervised exercises. Since optimal approach for patients with chronic back pain have yet not been defined based on evidence, good quality studies on the subject are necessary. Trial registration NCT01719276 PMID:23336703
NASA Astrophysics Data System (ADS)
Kobinata, Hideo; Yamashita, Hiroshi; Nomura, Eiichi; Nakajima, Ken; Kuroki, Yukinori
1998-12-01
A new method for proximity effect correction, suitable for large-field electron-beam (EB) projection lithography with high accelerating voltage, such as SCALPEL and PREVAIL in the case where a stencil mask is used, is discussed. In this lithography, a large-field is exposed by the same dose, and thus, the dose modification method, which is used in the variable-shaped beam and the cell projection methods, cannot be used in this case. In this study, we report on development of a new proximity effect correction method which uses a pattern modified stencil mask suitable for high accelerating voltage and large-field EB projection lithography. In order to obtain the mask bias value, we have investigated linewidth reduction, due to the proximity effect, in the peripheral memory cell area, and found that it could be expressed by a simple function and all the correction parameters were easily determined from only the mask pattern data. The proximity effect for the peripheral array pattern could also be corrected by considering the pattern density. Calculated linewidth deviation was 3% or less for a 0.07-µm-L/S memory cell pattern and 5% or less for a 0.14-µm-line and 0.42-µm-space peripheral array pattern, simultaneously.
77 FR 51745 - Proposed Flood Elevation Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
.... Specifically, it addresses the following flooding sources: Back Creek, Big Elk Creek, Bohemia River, Chesapeake... Areas'' addressed the following flooding sources: Back Creek, Big Elk Creek, Bohemia River, Chesapeake... modified elevation in feet, and/or communities affected for the following flooding sources: Big Elk Creek...
Shaw, William S; Linton, Steven J; Pransky, Glenn
2006-12-01
To assess, from the review literature, the extent to which effective strategies for reducing work absence after acute low back pain (LBP) match empirical risk factors. From 17 recent review articles (2000-2005), disability risk factors and interventions were cross-tabulated to assess levels of relative concordance. Potentially modifiable risk factors included 23 variables describing 3 workplace and 3 personal domains. Effective interventions included 25 strategies that were personal (physical or behavioral), engineering, or administrative in nature. There was a strong risk factor concordance for workplace technical and organizational interventions, graded activity exposure, and cognitive restructuring of pain beliefs. There was less risk factor concordance for exercise, back education, and RTW coordination. Few interventions focused on relieving emotional distress or improving job dissatisfaction, two well-supported risk factors. Gaps between the epidemiological and intervention research of back disability prevention could be reduced by testing mediators of intervention effects or by stratifying outcomes according to pre-intervention risk factors.
Research in Computational Astrobiology
NASA Technical Reports Server (NTRS)
Chaban, Galina; Colombano, Silvano; Scargle, Jeff; New, Michael H.; Pohorille, Andrew; Wilson, Michael A.
2003-01-01
We report on several projects in the field of computational astrobiology, which is devoted to advancing our understanding of the origin, evolution and distribution of life in the Universe using theoretical and computational tools. Research projects included modifying existing computer simulation codes to use efficient, multiple time step algorithms, statistical methods for analysis of astrophysical data via optimal partitioning methods, electronic structure calculations on water-nuclei acid complexes, incorporation of structural information into genomic sequence analysis methods and calculations of shock-induced formation of polycylic aromatic hydrocarbon compounds.
A web-based repository of surgical simulator projects.
Leskovský, Peter; Harders, Matthias; Székely, Gábor
2006-01-01
The use of computer-based surgical simulators for training of prospective surgeons has been a topic of research for more than a decade. As a result, a large number of academic projects have been carried out, and a growing number of commercial products are available on the market. Keeping track of all these endeavors for established groups as well as for newly started projects can be quite arduous. Gathering information on existing methods, already traveled research paths, and problems encountered is a time consuming task. To alleviate this situation, we have established a modifiable online repository of existing projects. It contains detailed information about a large number of simulator projects gathered from web pages, papers and personal communication. The database is modifiable (with password protected sections) and also allows for a simple statistical analysis of the collected data. For further information, the surgical repository web page can be found at www.virtualsurgery.vision.ee.ethz.ch.
In-line phase contrast micro-CT reconstruction for biomedical specimens.
Fu, Jian; Tan, Renbo
2014-01-01
X-ray phase contrast micro computed tomography (micro-CT) can non-destructively provide the internal structure information of soft tissues and low atomic number materials. It has become an invaluable analysis tool for biomedical specimens. Here an in-line phase contrast micro-CT reconstruction technique is reported, which consists of a projection extraction method and the conventional filter back-projection (FBP) reconstruction algorithm. The projection extraction is implemented by applying the Fourier transform to the forward projections of in-line phase contrast micro-CT. This work comprises a numerical study of the method and its experimental verification using a biomedical specimen dataset measured at an X-ray tube source micro-CT setup. The numerical and experimental results demonstrate that the presented technique can improve the imaging contrast of biomedical specimens. It will be of interest for a wide range of in-line phase contrast micro-CT applications in medicine and biology.
A Survey of the Use of Iterative Reconstruction Algorithms in Electron Microscopy
Otón, J.; Vilas, J. L.; Kazemi, M.; Melero, R.; del Caño, L.; Cuenca, J.; Conesa, P.; Gómez-Blanco, J.; Marabini, R.; Carazo, J. M.
2017-01-01
One of the key steps in Electron Microscopy is the tomographic reconstruction of a three-dimensional (3D) map of the specimen being studied from a set of two-dimensional (2D) projections acquired at the microscope. This tomographic reconstruction may be performed with different reconstruction algorithms that can be grouped into several large families: direct Fourier inversion methods, back-projection methods, Radon methods, or iterative algorithms. In this review, we focus on the latter family of algorithms, explaining the mathematical rationale behind the different algorithms in this family as they have been introduced in the field of Electron Microscopy. We cover their use in Single Particle Analysis (SPA) as well as in Electron Tomography (ET). PMID:29312997
Augmented reality based real-time subcutaneous vein imaging system
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-01-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed. PMID:27446690
Augmented reality based real-time subcutaneous vein imaging system.
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-07-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.
Electrochromic projection and writing device
Branz, Howard M.; Benson, David K.
2002-01-01
A display and projection apparatus includes an electrochromic material and a photoconductive material deposited in tandem used in conjunction with a light filtering means for filtering light transmitted through the electrochromic material. When an electric field is applied across the electrochromic material and the photoconductive material, light that is incident onto the photoconductive material through the surface of the projection apparatus causes the photoconductive material to conduct current locally in proportion to the amount of light incident on the photoconductive material. The flow of current causes the underlying portions of the electrochromic material to switch from an opaque state to a clear or transmissive state, thereby allowing back-light to propagate through the electrochromic material to create a visible image on the surface of the projection apparatus. Reversal of the electric field causes the electrochromic material to revert back to its opaque state, thereby blocking the transmission of back-light and effectively erasing the image from the surface of the projection apparatus.
ERIC Educational Resources Information Center
Gilbert, Jane; Bull, Ally
2014-01-01
This working paper sets out some of the early findings from a pilot project to explore the qualities that future-oriented teachers might need and how those qualities might be developed. The work began under a New Zealand Council for Educational Research (NZCER) project called Back to the Future and is now part of a Teaching & Learning Research…
NASA Astrophysics Data System (ADS)
Shin, Kang Sik; Jang, Eunseok; Cho, Jun-Sik; Yoo, Jinsu; Park, Joo Hyung; Byungsung, O.
2015-09-01
In recent decades, researchers have improved the efficiency of amorphous silicon solar cells in many ways. One of the easiest and most practical methods to improve solar-cell efficiency is adopting a back surface reflector (BSR) as the bottom layer or as the substrate. The BSR reflects the incident light back to the absorber layer in a solar cell, thus elongating the light path and causing the so-called "light trapping effect". The elongation of the light path in certain wavelength ranges can be enhanced with the proper scale of BSR surface structure or morphology. An aluminum substrate with a surface modified by aluminum anodizing is used to improve the optical properties for applications in amorphous silicon solar cells as a BSR in this research due to the high reflectivity and the low material cost. The solar cells with a BSR were formed and analyzed by using the following procedures: First, the surface of the aluminum substrate was degreased by using acetone, ethanol and distilled water, and it was chemically polished in a dilute alkali solution. After the cleaning process, the aluminum surface's morphology was modified by using a controlled anodization in a dilute acid solution to form oxide on the surface. The oxidized film was etched off by using an alkali solution to leave an aluminum surface with randomly-ordered dimple-patterns of approximately one micrometer in size. The anodizing conditions and the anodized aluminum surfaces after the oxide layer had been removed were systematically investigated according to the applied voltage. Finally, amorphous silicon solar cells were deposited on a modified aluminum plate by using dc magnetron sputtering. The surfaces of the anodized aluminum were observed by using field-emission scanning electron microscopy. The total and the diffuse reflectances of the surface-modified aluminum sheets were measured by using UV spectroscopy. We observed that the diffuse reflectances increased with increasing anodizing voltage. The properties of the solar cells on anodized aluminum substrates were analyzed by using a solar simulator.
OPeNDAP Server4: Buidling a High-Performance Server for the DAP by Leveraging Existing Software
NASA Astrophysics Data System (ADS)
Potter, N.; West, P.; Gallagher, J.; Garcia, J.; Fox, P.
2006-12-01
OPeNDAP has been working in conjunction with NCAR/ESSL/HAO to develop a modular, high performance data server that will be the successor to the current OPeNDAP data server. The new server, called Server4, is really two servers: A 'Back-End' data server which reads information from various types of data sources and packages the results in DAP objects; and A 'Front-End' which receives client DAP request and then decides how use features of the Back-End data server to build the correct responses. This architecture can be configured in several interesting ways: The Front- and Back-End components can be run on either the same or different machines, depending on security and performance needs, new Front-End software can be written to support other network data access protocols and local applications can interact directly with the Back-End data server. This new server's Back-End component will use the server infrastructure developed by HAO for use with the Earth System Grid II project. Extensions needed to use it as part of the new OPeNDAP server were minimal. The HAO server was modified so that it loads 'data handlers' at run-time. Each data handler module only needs to satisfy a simple interface which both enabled the existing data handlers written for the old OPeNDAP server to be directly used and also simplifies writing new handlers from scratch. The Back-End server leverages high- performance features developed for the ESG II project, so applications that can interact with it directly can read large volumes of data efficiently. The Front-End module of Server4 uses the Java Servlet system in place of the Common Gateway Interface (CGI) used in the past. New front-end modules can be written to support different network data access protocols, so that same server will ultimately be able to support more than the DAP/2.0 protocol. As an example, we will discuss a SOAP interface that's currently in development. In addition to support for DAP/2.0 and prototypical support for a SOAP interface, the new server includes support for the THREDDS cataloging protocol. THREDDS is tightly integrated into the Front-End of Server4. The Server4 Front-End can make full use of the advanced THREDDS features such as attribute specification and inheritance, custom catalogs which segue into automatically generated catalogs as well as providing a default behavior which requires almost no catalog configuration.
NASA Astrophysics Data System (ADS)
Ding, Hao; Wang, Yong; Guo, Sini; Xu, Xiaofeng; Che, Cheng
2016-04-01
International projects are different from general domestic ones. In order to analyse the differences, a tripartite game model is built up to describe the relationship among owner, supervisor and general contractor, and some measures are given for the owner to more effectively complete the project. In addition, a project schedule selection model is formulated and a new benefit allocation method is proposed by introducing a new modified Shapley value with weighted factor.
On adaptive modified projective synchronization of a supply chain management system
NASA Astrophysics Data System (ADS)
Tirandaz, Hamed
2017-12-01
In this paper, the synchronization problem of a chaotic supply chain management system is studied. A novel adaptive modified projective synchronization method is introduced to control the behaviour of the leader supply chain system by a follower chaotic system and to adjust the leader system parameters until the measurable errors of the system parameters converge to zero. The stability evaluation and convergence analysis are carried out by the Lyapanov stability theorem. The proposed synchronization and antisynchronization techniques are studied for identical supply chain chaotic systems. Finally, some numerical simulations are presented to verify the effectiveness of the theoretical discussions.
Experience with modified aerospace reliability and quality assurance method for wind turbines
NASA Technical Reports Server (NTRS)
Klein, W. E.
1982-01-01
The SR&QA approach assures that the machine is not hazardous to the public or operating personnel, can operate unattended on a utility grid, demonstrates reliability operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The approach consisted of modified failure modes and effects analysis (FMEA) during the design phase, minimal hardware inspection during parts fabrication, and three simple documents to control activities during machine construction and operation. Five years experience shows that this low cost approach works well enough that it should be considered by others for similar projects.
NASA Astrophysics Data System (ADS)
Buendía, M.; Salvador, R.; Cibrián, R.; Laguia, M.; Sotoca, J. M.
1999-01-01
The projection of structured light is a technique frequently used to determine the surface shape of an object. In this paper, a new procedure is described that efficiently resolves the correspondence between the knots of the projected grid and those obtained on the object when the projection is made. The method is based on the use of three images of the projected grid. In two of them the grid is projected over a flat surface placed, respectively, before and behind the object; both images are used for calibration. In the third image the grid is projected over the object. It is not reliant on accurate determination of the camera and projector pair relative to the grid and object. Once the method is calibrated, we can obtain the surface function by just analysing the projected grid on the object. The procedure is especially suitable for the study of objects without discontinuities or large depth gradients. It can be employed for determining, in a non-invasive way, the patient's back surface function. Symmetry differences permit a quantitative diagnosis of spinal deformities such as scoliosis.
2009-06-01
CAPE CANAVERAL, Fla. – NASA 911, one of NASA's two modified Boeing 747 space shuttle carriers, lifts off Runway 22L at Edwards Air Force Base with the shuttle Atlantis on its back on the first leg of Atlantis' ferry flight back to NASA's Kennedy Space Center in Florida. Photo credit: NASA/Tom Tschida
Park, Sang-Sub
2014-01-01
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
BPSK Demodulation Using Digital Signal Processing
NASA Technical Reports Server (NTRS)
Garcia, Thomas R.
1996-01-01
A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.
Finite difference time domain modeling of spiral antennas
NASA Technical Reports Server (NTRS)
Penney, Christopher W.; Beggs, John H.; Luebbers, Raymond J.
1992-01-01
The objectives outlined in the original proposal for this project were to create a well-documented computer analysis model based on the finite-difference, time-domain (FDTD) method that would be capable of computing antenna impedance, far-zone radiation patterns, and radar cross-section (RCS). The ability to model a variety of penetrable materials in addition to conductors is also desired. The spiral antennas under study by this project meet these requirements since they are constructed of slots cut into conducting surfaces which are backed by dielectric materials.
Bessel beam fluorescence lifetime tomography of live embryos (Conference Presentation)
NASA Astrophysics Data System (ADS)
Xu, Dongli; Peng, Leilei
2016-03-01
Optical tomography allows isotropic 3D imaging of embryos. Scanning-laser optical tomography (SLOT) has superior light collecting efficiency than wide-field optical tomography, making it ideal for fluorescence imaging of live embryos. We previously reported an imaging system that combines SLOT with a novel Fourier-multiplexed fluorescence lifetime imaging (FmFLIM) technique named FmFLIM-SLOT. FmFLIM-SLOT performs multiplexed FLIM-FRET readout of multiple FRET sensors in live embryos. Here we report a recent effort on improving the spatial resolution of the FmFLIM-SLOT system in order to image complex biochemical processes in live embryos at the cellular level. Optical tomography has to compromise between resolution and the depth of view. In SLOT, the commonly-used focused Gaussian beam diverges quickly from the focal plane, making it impossible to achieve high resolution imaging in a large volume specimen. We thus introduce Bessel beam laser-scanning tomography, which illuminates the sample with a spatial-light-modulator-generated Bessel beam that has an extended focal depth. The Bessel beam is scanned across the whole specimen. Fluorescence projection images are acquired at equal angular intervals as the sample rotates. Reconstruction artifacts due to annular-rings of the Bessel beam are removed by a modified 3D filtered back projection algorithm. Furthermore, in combination of Fourier-multiplexing fluorescence lifetime imaging (FmFLIM) method, the Bessel FmFLIM-SLOT system is capable of perform 3D lifetime imaging of live embryos at cellular resolution. The system is applied to in-vivo imaging of transgenic Zebrafish embryos. Results prove that Bessel FmFLIM-SLOT is a promising imaging method in development biology research.
NASA Astrophysics Data System (ADS)
Parambath Vinayan, Bhaghavathi; Nagar, Rupali; Ramaprabhu, Sundara
2016-09-01
We investigate the electrocatalytic activity of PtAu alloy nanoparticles supported on various chemically modified carbon morphologies towards oxygen reduction reaction (ORR) and methanol oxidation reaction (MOR). The surface-modification of graphene nanosheets (f-G), multi-walled carbon nanotubes (f-MWNTs) and (graphene nanosheets-carbon nanotubes) hybrid support (f-G-MWNTs) were carried out by soft functionalization method using a cationic polyelectrolyte poly-(diallyldimethyl ammonium chloride). The Pt and PtAu alloy nanoparticles were dispersed over chemically modified carbon supports by sodium-borohydride assisted modified polyol reduction method. The electrochemical performance of all electrocatalysts were studied by half- and full-cell proton exchange membrane fuel cell (PEMFC) measurements and PtAu/f-G-MWNTs catalyst comparatively yielded the best catalytic performance. PEMFC full cell measurements of PtAu/f-G-MWNTs cathode electrocatalyst yield a maximum power density of 319 mW cm-2 at 60 °C without any back pressure,which is 2.1 times higher than that of cathode electrocatalyst Pt on graphene support. The high ORR and MOR activity of PtAu/f-G-MWNTs electrocatalyst is due to the alloying effect and inherent beneficial properties of porous hybrid nanocarbon support.
The Early Childhood Community Gives Back: Exchange Center Makeover Project
ERIC Educational Resources Information Center
Exchange: The Early Childhood Leaders' Magazine Since 1978, 2010
2010-01-01
The early childhood community gives back. With the extreme generosity of the "Exchange" Makeover Project partners, Jewel's Learning Center, selected as the winner of the Center Makeover, will be awarded with new and innovative tools to help build an even stronger educational foundation for the children attending the center. Included will be new…
Reduced projection angles for binary tomography with particle aggregation.
Al-Rifaie, Mohammad Majid; Blackwell, Tim
This paper extends particle aggregate reconstruction technique (PART), a reconstruction algorithm for binary tomography based on the movement of particles. PART supposes that pixel values are particles, and that particles diffuse through the image, staying together in regions of uniform pixel value known as aggregates. In this work, a variation of this algorithm is proposed and a focus is placed on reducing the number of projections and whether this impacts the reconstruction of images. The algorithm is tested on three phantoms of varying sizes and numbers of forward projections and compared to filtered back projection, a random search algorithm and to SART, a standard algebraic reconstruction method. It is shown that the proposed algorithm outperforms the aforementioned algorithms on small numbers of projections. This potentially makes the algorithm attractive in scenarios where collecting less projection data are inevitable.
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Endeavour on top lifts of
NASA Technical Reports Server (NTRS)
2001-01-01
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Endeavour on top lifts off from Edwards Air Force Base to begin its ferry flight back to the Kennedy Space Center in Florida.
NASA Astrophysics Data System (ADS)
Coakley, Kevin J.; Vecchia, Dominic F.; Hussey, Daniel S.; Jacobson, David L.
2013-10-01
At the NIST Neutron Imaging Facility, we collect neutron projection data for both the dry and wet states of a Proton-Exchange-Membrane (PEM) fuel cell. Transmitted thermal neutrons captured in a scintillator doped with lithium-6 produce scintillation light that is detected by an amorphous silicon detector. Based on joint analysis of the dry and wet state projection data, we reconstruct a residual neutron attenuation image with a Penalized Likelihood method with an edge-preserving Huber penalty function that has two parameters that control how well jumps in the reconstruction are preserved and how well noisy fluctuations are smoothed out. The choice of these parameters greatly influences the resulting reconstruction. We present a data-driven method that objectively selects these parameters, and study its performance for both simulated and experimental data. Before reconstruction, we transform the projection data so that the variance-to-mean ratio is approximately one. For both simulated and measured projection data, the Penalized Likelihood method reconstruction is visually sharper than a reconstruction yielded by a standard Filtered Back Projection method. In an idealized simulation experiment, we demonstrate that the cross validation procedure selects regularization parameters that yield a reconstruction that is nearly optimal according to a root-mean-square prediction error criterion.
Magalhaes, Mauricio Oliveira; França, Fábio Jorge Renovato; Burke, Thomaz Nogueira; Ramos, Luiz Armando Vidal; de Moura Campos Carvalho e Silva, Ana Paula; Almeida, Gabriel Peixoto Leao; Yuan, Susan Lee King; Marques, Amélia Pasqual
2013-01-21
Low back pain is a relevant public health problem, being an important cause of work absenteeism worldwide, as well as affecting the quality of life of sufferers and their individual functional performances. Supervised active physical routines and of cognitive-behavioral therapies are recommended for the treatment of chronic Low back pain, although evidence to support the effectiveness of different techniques is missing. Accordingly, the aim of this study is to contrast the effectiveness of two types of exercises, graded activity or supervised, in decreasing symptoms of chronic low back pain. Sample will consist of 66 patients, blindly allocated into one of two groups: 1) Graded activity which, based on an operant approach, will use time-contingent methods aiming to increase participants' activity levels; 2) Supervised exercise, where participants will be trained for strengthening, stretching, and motor control targeting different muscle groups. Interventions will last one hour, and will happen twice a week for 6 weeks. Outcomes (pain, disability, quality of life, global perceived effect, return to work, physical activity, physical capacity, and kinesiophobia) will be assessed at baseline, at treatment end, and three and six months after treatment end. Data collection will be conducted by an investigator blinded to treatment allocation. This project describes the randomisation method that will be used to compare the effectiveness of two different treatments for chronic low back pain: graded activity and supervised exercises. Since optimal approach for patients with chronic back pain have yet not been defined based on evidence, good quality studies on the subject are necessary. NCT01719276.
Influence of climatic conditions on antiperspirant efficacy determined at different test areas.
Brandt, Marianne; Bielfeldt, Stephan; Springmann, Gunja; Wilhelm, Klaus-Peter
2008-05-01
The efficacy of antiperspirants is a current topic among the developers of cosmetic products. According to the Food and Drug Administration (FDA) for the US market, efficacy testing performed in the axilla of human volunteers is mandatory. Another method is yet available, which enables comparison of more than one antiperspirant formula in a single study by performing the test on the backs of volunteers. However, how reproducible are these methods, comparing between the back and axilla? Do they differ as a result of seasonal variation? Is a correlation between the results of the two methods possible? To answer these questions, the antiperspirant efficacy of aluminium chlorohydrate (ACH) aqueous solutions was investigated in the axilla and on the backs of volunteers, in four separate clinical studies covering cold and warm seasons. Four days of product application were followed by thermal sweat induction on the fifth day, using a sauna. The amount of sweat recovered by weighing cotton pads before and after sweat induction was used to calculate sweat reduction. Testing in the axilla and on the back was performed on the same volunteers simultaneously to achieve the best comparable data. For this reason, the FDA guideline was slightly modified to thermal stimulation in a sauna instead of in a hot room. Increasing concentrations of ACH in aqueous solutions on the backs of volunteers showed a saturation for 8% ACH with a sweat reduction of approximately 50%. The antiperspirant efficacy of solutions containing 4%, 8% or 12% ACH was repeatedly found at the same levels, when tested on the backs during summer, autumn and winter time. Axilla tests, with an 8% ACH aqueous solution, showed strongly varying results for summer and winter time, represented by sweat reduction values of -2% to 25%. As an assumption, these high variations might result from reduced gel formation in cold seasons due to low humidity in the axillae during the application phase. On the back, this effect was avoided by applying occlusive foils after product application. To gain further insight, a study, during which summer conditions were artificially simulated by thermal stimulation during the application phase, again showed decreased antiperspirant efficacy in the axilla for winter conditions with sweat reduction values of 2%, compared with 25% under simulated summer conditions. These strongly varying values of sweat reduction in the axilla under summer and winter conditions make comparisons between antiperspirant products difficult and a statement about correlation between the two test sites back and axilla impossible. A standardization of the application phase, comparable to the simulated summer conditions described here, could be a solution to reduce the high variation of results in the axilla. Consequently, testing on the back is not only a more cost-effective method to investigate the antiperspirant efficacy of more than one formulation, but a reproducible method more independent of climatic influences during test implementation than the axilla test method. It could, therefore, be regarded as the method of choice for discriminating antiperspirant efficacy between several products during development of new antiperspirant formulations.
Characterizing the reflectivity of handheld display devices.
Liu, Peter; Badano, Aldo
2014-08-01
With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements, both luminance and illuminance increased as the size of the display window decreased. The TG18 method does not account for this variability. The authors conclude that the method requires a definitive description of the back panel used in the light source setup. The methods described in the TG18 document may need to be improved to provide consistent comparisons of desktop monitors, phones, and tablets.
50 CFR 216.275 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Navy shall complete an Integrated Comprehensive Monitoring Plan (ICMP) in 2009. This planning and adaptive management tool shall include: (1) A method for prioritizing monitoring projects that clearly... potentially modify subsequent monitoring and mitigation. (4) An adaptive management plan. (5) A method for...
Ryu, Young Jin; Choi, Young Hun; Cheon, Jung-Eun; Ha, Seongmin; Kim, Woo Sun; Kim, In-One
2016-03-01
CT of pediatric phantoms can provide useful guidance to the optimization of knowledge-based iterative reconstruction CT. To compare radiation dose and image quality of CT images obtained at different radiation doses reconstructed with knowledge-based iterative reconstruction, hybrid iterative reconstruction and filtered back-projection. We scanned a 5-year anthropomorphic phantom at seven levels of radiation. We then reconstructed CT data with knowledge-based iterative reconstruction (iterative model reconstruction [IMR] levels 1, 2 and 3; Philips Healthcare, Andover, MA), hybrid iterative reconstruction (iDose(4), levels 3 and 7; Philips Healthcare, Andover, MA) and filtered back-projection. The noise, signal-to-noise ratio and contrast-to-noise ratio were calculated. We evaluated low-contrast resolutions and detectability by low-contrast targets and subjective and objective spatial resolutions by the line pairs and wire. With radiation at 100 peak kVp and 100 mAs (3.64 mSv), the relative doses ranged from 5% (0.19 mSv) to 150% (5.46 mSv). Lower noise and higher signal-to-noise, contrast-to-noise and objective spatial resolution were generally achieved in ascending order of filtered back-projection, iDose(4) levels 3 and 7, and IMR levels 1, 2 and 3, at all radiation dose levels. Compared with filtered back-projection at 100% dose, similar noise levels were obtained on IMR level 2 images at 24% dose and iDose(4) level 3 images at 50% dose, respectively. Regarding low-contrast resolution, low-contrast detectability and objective spatial resolution, IMR level 2 images at 24% dose showed comparable image quality with filtered back-projection at 100% dose. Subjective spatial resolution was not greatly affected by reconstruction algorithm. Reduced-dose IMR obtained at 0.92 mSv (24%) showed similar image quality to routine-dose filtered back-projection obtained at 3.64 mSv (100%), and half-dose iDose(4) obtained at 1.81 mSv.
Balneotherapy for chronic low back pain: a randomized, controlled study.
Kesiktas, Nur; Karakas, Sinem; Gun, Kerem; Gun, Nuran; Murat, Sadiye; Uludag, Murat
2012-10-01
A large number of treatments were used for patients with chronic low back pain. Frequent episodes have been reported very high. Although balneotherapy was found effective in this disease, there are not well-designed studies. We aimed to determine the effectiveness of balneotherapy versus physical therapy in patients with chronic low back pain. Exercise was added to both treatment programs. Sixty patients with chronic low back pain were randomly divided into two groups. Physical modalities plus exercise were applied to group 1, and group 2 was received balneotherapy plus exercise for ten sessions. The following parameters were measured: visual analogue scale at rest and movement for pain, paracetamol dose, manual muscle test for lumber muscles, modified Schoeber' test, Oswestry disability index, and Short-Form 36 at the beginning and end of the therapies and at the 3 months follow-up. The statistical analyses were performed using the SPSS 10.0 program. Both groups achieved significant improvements within themselves. But balneotherapy groups were improved at back extensor muscle test (P < 0.05), modified Schoeber's test (P < 0.03), Oswestry disability index, and the some scores of SF 36 (energy vitality, social function, role limitations related to physical problems, and general health P < 0.05). Balneotherapy combined with exercise therapy had advantages than therapy with physical modalities plus exercise in improving quality of life and flexibility of patients with chronic low back pain.
Aerodynamic characteristics of the Fiat UNO car
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costelli, A.F.
1984-01-01
The purpose of this article is to describe the work conducted in the aerodynamic field throughout the 4-year development and engineering time span required by the project of the UNO car. A description is given of all the parametric studies carried out. Through these studies two types of cars at present in production were defined and the characteristics of a possible future sports version laid down. A movable device, to be fitted in the back window, was also set up and patented. When actuated it reduces soiling of back window. A description is also provided of the measurements made inmore » the car flow field and some considerations are outlined about the method applied. This method is still in development phase but it already permits some considerations and in-depth investigations to be made on the vehicle wake.« less
Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo
2018-05-07
In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
NASA Astrophysics Data System (ADS)
Busto, S.; Ferrín, J. L.; Toro, E. F.; Vázquez-Cendón, M. E.
2018-01-01
In this paper the projection hybrid FV/FE method presented in [1] is extended to account for species transport equations. Furthermore, turbulent regimes are also considered thanks to the k-ε model. Regarding the transport diffusion stage new schemes of high order of accuracy are developed. The CVC Kolgan-type scheme and ADER methodology are extended to 3D. The latter is modified in order to profit from the dual mesh employed by the projection algorithm and the derivatives involved in the diffusion term are discretized using a Galerkin approach. The accuracy and stability analysis of the new method are carried out for the advection-diffusion-reaction equation. Within the projection stage the pressure correction is computed by a piecewise linear finite element method. Numerical results are presented, aimed at verifying the formal order of accuracy of the scheme and to assess the performance of the method on several realistic test problems.
Development of ceramic-coated weld backing bars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eggleston, B.R.
1994-10-20
In shipbuilding and many other industries, copper weld backing bars are used to draw the heat out of the weld. The problem that some users of these bars encounter is that these bars, on occasion, actually melt in spots and become welded to the weld plates. After this happens a number of times, the backing bar becomes so degraded that it must be either discarded or machined, both of which are very costly and time-consuming actions. To avoid this fusion between the backing bar and the weld plate, the weld processes that are used cannot be ones of high beatmore » input. This requirement is very limiting when thick plates are being welded. The plates must be beveled, and more weld passes must be run. These problems are also costly and time consuming. The aim of this project is to find a way to produce backing bars with nearly the same `chilling` effect but with both a greater resistance to molten metal and resistance to arcing to the backing bar itself. A possible solution currently being tested is to coat the copper bars with a thin layer of a ceramic coating. The procedure used was to coat the copper bars with either alumina or spinel by a plasma spraying method.« less
Magneto-transport study of top- and back-gated LaAlO{sub 3}/SrTiO{sub 3} heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W., E-mail: W.Liu@unige.ch; Gariglio, S.; Fête, A.
2015-06-01
We report a detailed analysis of magneto-transport properties of top- and back-gated LaAlO{sub 3}/SrTiO{sub 3} heterostructures. Efficient modulation in magneto-resistance, carrier density, and mobility of the two-dimensional electron liquid present at the interface is achieved by sweeping top and back gate voltages. Analyzing those changes with respect to the carrier density tuning, we observe that the back gate strongly modifies the electron mobility while the top gate mainly varies the carrier density. The evolution of the spin-orbit interaction is also followed as a function of top and back gating.
Analysis of pulse thermography using similarities between wave and diffusion propagation
NASA Astrophysics Data System (ADS)
Gershenson, M.
2017-05-01
Pulse thermography or thermal wave imaging are commonly used as nondestructive evaluation (NDE) method. While the technical aspect has evolve with time, theoretical interpretation is lagging. Interpretation is still using curved fitting on a log log scale. A new approach based directly on the governing differential equation is introduced. By using relationships between wave propagation and the diffusive propagation of thermal excitation, it is shown that one can transform from solutions in one type of propagation to the other. The method is based on the similarities between the Laplace transforms of the diffusion equation and the wave equation. For diffusive propagation we have the Laplace variable s to the first power, while for the wave propagation similar equations occur with s2. For discrete time the transformation between the domains is performed by multiplying the temperature data vector by a matrix. The transform is local. The performance of the techniques is tested on synthetic data. The application of common back projection techniques used in the processing of wave data is also demonstrated. The combined use of the transform and back projection makes it possible to improve both depth and lateral resolution of transient thermography.
NASA Astrophysics Data System (ADS)
Morozov, Alexey Nikolaevich; Vaganova, Natalya V.; Asming, Vladimir E.; Konechnaya, Yana V.; Evtyugina, Zinaida A.
2018-05-01
We have relocated seismic events registered within the Barents and Kara sea region from early twentieth century to 1989 with a view to creating a relocated catalog. For the relocation, we collected all available seismic bulletins from the global network using data from the ISC Bulletin (International Seismological Centre), ISC-GEM project (International Seismological Centre-Global Earthquake Model), EuroSeismos project, and by Soviet seismic stations from Geophysical Survey of the Russian Academy of Sciences. The location was performed by applying a modified method of generalized beamforming. We have considered several travel time models and selected one with the best location accuracy for ground truth events. Verification of the modified method and selection of the travel time model were performed using data on four nuclear explosions that occurred in the area of the Novaya Zemlya Archipelago and in the north of the European part of Russia. The modified method and the Barents travel time model provide sufficient accuracy for event location in the region. The relocation procedure was applied to 31 of 36 seismic events registered within the Barents and Kara sea region.
NASA Astrophysics Data System (ADS)
Meng, L.; Ampuero, J. P.; Rendon, H.
2010-12-01
Back projection of teleseismic waves based on array processing has become a popular technique for earthquake source imaging,in particular to track the areas of the source that generate the strongest high frequency radiation. The technique has been previously applied to study the rupture process of the Sumatra earthquake and the supershear rupture of the Kunlun earthquakes. Here we attempt to image the Haiti earthquake using the data recorded by Venezuela National Seismic Network (VNSN). The network is composed of 22 broad-band stations with an East-West oriented geometry, and is located approximately 10 degrees away from Haiti in the perpendicular direction to the Enriquillo fault strike. This is the first opportunity to exploit the privileged position of the VNSN to study large earthquake ruptures in the Caribbean region. This is also a great opportunity to explore the back projection scheme of the crustal Pn phase at regional distances,which provides unique complementary insights to the teleseismic source inversions. The challenge in the analysis of the 2010 M7.0 Haiti earthquake is its very compact source region, possibly shorter than 30km, which is below the resolution limit of standard back projection techniques based on beamforming. Results of back projection analysis using the teleseismic USarray data reveal little details of the rupture process. To overcome the classical resolution limit we explored the Multiple Signal Classification method (MUSIC), a high-resolution array processing technique based on the signal-noise orthognality in the eigen space of the data covariance, which achieves both enhanced resolution and better ability to resolve closely spaced sources. We experiment with various synthetic earthquake scenarios to test the resolution. We find that MUSIC provides at least 3 times higher resolution than beamforming. We also study the inherent bias due to the interferences of coherent Green’s functions, which leads to a potential quantification of biased uncertainty of the back projection. Preliminary results from the Venezuela data set shows an East to West rupture propagation along the fault with sub-Rayleigh rupture speed, consistent with a compact source with two significant asperities which are confirmed by source time function obtained from Green’s function deconvolution and other source inversion results. These efforts could lead the Venezuela National Seismic Network to play a prominent role in the timely characterization of the rupture process of large earthquakes in the Caribbean, including the future ruptures along the yet unbroken segments of the Enriquillo fault system.
A modified dodge algorithm for the parabolized Navier-Stokes equations and compressible duct flows
NASA Technical Reports Server (NTRS)
Cooke, C. H.
1981-01-01
A revised version of a split-velocity method for numerical calculation of compressible duct flow was developed. The revision incorporates balancing of mass flow rates on each marching step in order to maintain front-to-back continuity during the calculation. The (checkerboard) zebra algorithm is applied to solution of the three-dimensional continuity equation in conservative form. A second-order A-stable linear multistep method is employed in effecting a marching solution of the parabolized momentum equations. A checkerboard successive overrelaxation iteration is used to solve the resulting implicit nonlinear systems of finite-difference equations which govern stepwise transition.
Wang, Nu; Boswell, Paul G
2017-10-20
Gradient retention times are difficult to project from the underlying retention factor (k) vs. solvent composition (φ) relationships. A major reason for this difficulty is that gradients produced by HPLC pumps are imperfect - gradient delay, gradient dispersion, and solvent mis-proportioning are all difficult to account for in calculations. However, we recently showed that a gradient "back-calculation" methodology can measure these imperfections and take them into account. In RPLC, when the back-calculation methodology was used, error in projected gradient retention times is as low as could be expected based on repeatability in the k vs. φ relationships. HILIC, however, presents a new challenge: the selectivity of HILIC columns drift strongly over time. Retention is repeatable in short time, but selectivity frequently drifts over the course of weeks. In this study, we set out to understand if the issue of selectivity drift can be avoid by doing our experiments quickly, and if there any other factors that make it difficult to predict gradient retention times from isocratic k vs. φ relationships when gradient imperfections are taken into account with the back-calculation methodology. While in past reports, the accuracy of retention projections was >5%, the back-calculation methodology brought our error down to ∼1%. This result was 6-43 times more accurate than projections made using ideal gradients and 3-5 times more accurate than the same retention projections made using offset gradients (i.e., gradients that only took gradient delay into account). Still, the error remained higher in our HILIC projections than in RPLC. Based on the shape of the back-calculated gradients, we suspect the higher error is a result of prominent gradient distortion caused by strong, preferential water uptake from the mobile phase into the stationary phase during the gradient - a factor our model did not properly take into account. It appears that, at least with the stationary phase we used, column distortion is an important factor to take into account in retention projection in HILIC that is not usually important in RPLC. Copyright © 2017 Elsevier B.V. All rights reserved.
Iris double recognition based on modified evolutionary neural network
NASA Astrophysics Data System (ADS)
Liu, Shuai; Liu, Yuan-Ning; Zhu, Xiao-Dong; Huo, Guang; Liu, Wen-Tao; Feng, Jia-Kai
2017-11-01
Aiming at multicategory iris recognition under illumination and noise interference, this paper proposes a method of iris double recognition based on a modified evolutionary neural network. An equalization histogram and Laplace of Gaussian operator are used to process the iris to suppress illumination and noise interference and Haar wavelet to convert the iris feature to binary feature encoding. Calculate the Hamming distance for the test iris and template iris , and compare with classification threshold, determine the type of iris. If the iris cannot be identified as a different type, there needs to be a secondary recognition. The connection weights in back-propagation (BP) neural network use modified evolutionary neural network to adaptively train. The modified neural network is composed of particle swarm optimization with mutation operator and BP neural network. According to different iris libraries in different circumstances of experimental results, under illumination and noise interference, the correct recognition rate of this algorithm is higher, the ROC curve is closer to the coordinate axis, the training and recognition time is shorter, and the stability and the robustness are better.
Ishihara, Satoru; Kotomura, Naoe; Yamamoto, Naoki; Ochiai, Hiroshi
2017-08-15
Ligation-mediated polymerase chain reaction (LM-PCR) is a common technique for amplification of a pool of DNA fragments. Here, a double-stranded oligonucleotide consisting of two primer sequences in back-to-back orientation was designed as an adapter for LM-PCR. When DNA fragments were ligated with this adapter, the fragments were sandwiched between two adapters in random orientations. In the ensuing PCR, ligation products linked at each end to an opposite side of the adapter, i.e. to a distinct primer sequence, were preferentially amplified compared with products linked at each end to an identical primer sequence. The use of this adapter in LM-PCR reduced the impairment of PCR by substrate DNA with a high GC content, compared with the use of traditional LM-PCR adapters. This result suggested that our method has the potential to contribute to reduction of the amplification bias that is caused by an intrinsic property of the sequence context in substrate DNA. A DNA preparation obtained from a chromatin immunoprecipitation assay using pulldown of a specific form of histone H3 was successfully amplified using the modified LM-PCR, and the amplified products could be used as probes in a fluorescence in situ hybridization analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
Isometric endurance of the back extensors in school-aged adolescents with and without low back pain.
Johnson, Olubusola E; Mbada, Chidozie E; Akosile, Christopher O; Agbeja, Oyinade A
2009-01-01
Studies on back extensor endurance in adolescents are scarce. This study sought to establish reference data and pattern of back extensor endurance in school-aged adolescents with and without low-back pain (LBP) from Nigeria. This study recruited 625 adolescents aged 11 to 19 years from eight randomly selected secondary schools. The modified Biering-Sørensen test of Static Muscular Endurance (BSME) was used to assess isometric endurance of the back extensors. Demographic and anthropometric data were collected. A modified LBP questionnaire was used to assess the presence of LBP. Descriptive and inferential analyses were used to analyze data. Significance was set at 0.05 alpha-level. The mean isometric holding time (IHT) of all the participants was 132.9 $\\pm$ 65.6. Males had significantly higher significant (p=0.026) IHT than females. Adolescents without LBP had a higher significant IHT (p=0.042) than those with reported history of previous LBP and those with present LBP (p=0.000) respectively. Using percentile values, poor endurance was defined as IHT that is < 90.0 s and < 67 s for males and females respectively; medium endurance was defined as IHT that ranged between 90 and 193 s and 67 and 170 s for males and females respectively while good endurance was defined as IHT that is > 193 s and > 170 s for males and females respectively. IHT was significantly related to each of body mass index, hip circumference and waist-to-hip ratio (p < 0.05). Isometric back extensors endurance in Nigerian adolescents was comparable to the original Biering-Sørensen mean value. Majority of the participants had medium endurance performance with the back endurance pattern in the ratio 1:2:1. Male had higher isometric back extensors endurance than females. Decreased isometric back extensors endurance was associated with the presence of LBP in adolescents.
New technology in dietary assessment: a review of digital methods in improving food record accuracy.
Stumbo, Phyllis J
2013-02-01
Methods for conducting dietary assessment in the United States date back to the early twentieth century. Methods of assessment encompassed dietary records, written and spoken dietary recalls, FFQ using pencil and paper and more recently computer and internet applications. Emerging innovations involve camera and mobile telephone technology to capture food and meal images. This paper describes six projects sponsored by the United States National Institutes of Health that use digital methods to improve food records and two mobile phone applications using crowdsourcing. The techniques under development show promise for improving accuracy of food records.
NASA Astrophysics Data System (ADS)
Yan, Zhen-Ya; Xie, Fu-Ding; Zhang, Hong-Qing
2001-07-01
Both the direct method due to Clarkson and Kruskal and the improved direct method due to Lou are extended to reduce the high-order modified Boussinesq equation with the damping term (HMBEDT) arising in the general Fermi-Pasta-Ulam model. As a result, several types of similarity reductions are obtained. It is easy to show that the nonlinear wave equation is not integrable under the sense of Ablowitz's conjecture from the reduction results obtained. In addition, kink-shaped solitary wave solutions, which are of important physical significance, are found for HMBEDT based on the obtained reduction equation. The project supported by National Natural Science Foundation of China under Grant No. 19572022, the National Key Basic Research Development Project Program of China under Grant No. G1998030600 and Doctoral Foundation of China under Grant No. 98014119
Initial Back-to-Back Fission Chamber Testing in ATRC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benjamin Chase; Troy Unruh; Joy Rempe
2014-06-01
Development and testing of in-pile, real-time neutron sensors for use in Materials Test Reactor experiments is an ongoing project at Idaho National Laboratory. The Advanced Test Reactor National Scientific User Facility has sponsored a series of projects to evaluate neutron detector options in the Advanced Test Reactor Critical Facility (ATRC). Special hardware was designed and fabricated to enable testing of the detectors in the ATRC. Initial testing of Self-Powered Neutron Detectors and miniature fission chambers produced promising results. Follow-on testing required more experiment hardware to be developed. The follow-on testing used a Back-to-Back fission chamber with the intent to providemore » calibration data, and a means of measuring spectral indices. As indicated within this document, this is the first time in decades that BTB fission chambers have been used in INL facilities. Results from these fission chamber measurements provide a baseline reference for future measurements with Back-to-Back fission chambers.« less
NASA Astrophysics Data System (ADS)
Naeimi, Hossein; Nayebi Shahabi, Mina; Mohammadi, Sohrab
2017-08-01
In developing countries, small and micro hydropower plants are very effective source for electricity generation with energy pay-back time (EPBT) less than other conventional electricity generation systems. Using pump as turbine (PAT) is an attractive, significant and cost-effective alternative. Pump manufacturers do not normally provide the characteristic curves of their pumps working as turbines. Therefore, choosing an appropriate Pump to work as a turbine is essential in implementing the small-hydro plants. In this paper, in order to find the best fitting method to choose a PAT, the results of a small-hydro plant implemented on the by-pass of a Pressure Reducing Valve (PRV) in Urmia city in Iran are presented. Some of the prediction methods of Best Efficiency Point of PATs are derived. Then, the results of implemented project have been compared to the prediction methods results and the deviation of from measured data were considered and discussed and the best method that predicts the specifications of PAT more accurately determined. Finally, the energy pay-back time for the plant is calculated.
A neural network approach for image reconstruction in electron magnetic resonance tomography.
Durairaj, D Christopher; Krishna, Murali C; Murugesan, Ramachandran
2007-10-01
An object-oriented, artificial neural network (ANN) based, application system for reconstruction of two-dimensional spatial images in electron magnetic resonance (EMR) tomography is presented. The standard back propagation algorithm is utilized to train a three-layer sigmoidal feed-forward, supervised, ANN to perform the image reconstruction. The network learns the relationship between the 'ideal' images that are reconstructed using filtered back projection (FBP) technique and the corresponding projection data (sinograms). The input layer of the network is provided with a training set that contains projection data from various phantoms as well as in vivo objects, acquired from an EMR imager. Twenty five different network configurations are investigated to test the ability of the generalization of the network. The trained ANN then reconstructs two-dimensional temporal spatial images that present the distribution of free radicals in biological systems. Image reconstruction by the trained neural network shows better time complexity than the conventional iterative reconstruction algorithms such as multiplicative algebraic reconstruction technique (MART). The network is further explored for image reconstruction from 'noisy' EMR data and the results show better performance than the FBP method. The network is also tested for its ability to reconstruct from limited-angle EMR data set.
Through the Regional Applied Research Effort (RARE) program, the Chemical Exposure Research Branch and Region 9 personnel in San Francisco, California are collaborating on a project to explore sample pretreatment and preconcentration techniques to lower the method detection limit...
NASA Astrophysics Data System (ADS)
Guo, Zhenyan; Song, Yang; Yuan, Qun; Wulan, Tuya; Chen, Lei
2017-06-01
In this paper, a transient multi-parameter three-dimensional (3D) reconstruction method is proposed to diagnose and visualize a combustion flow field. Emission and transmission tomography based on spatial phase-shifted technology are combined to reconstruct, simultaneously, the various physical parameter distributions of a propane flame. Two cameras triggered by the internal trigger mode capture the projection information of the emission and moiré tomography, respectively. A two-step spatial phase-shifting method is applied to extract the phase distribution in the moiré fringes. By using the filtered back-projection algorithm, we reconstruct the 3D refractive-index distribution of the combustion flow field. Finally, the 3D temperature distribution of the flame is obtained from the refractive index distribution using the Gladstone-Dale equation. Meanwhile, the 3D intensity distribution is reconstructed based on the radiation projections from the emission tomography. Therefore, the structure and edge information of the propane flame are well visualized.
Project Word-Back: Exploratory Follow-Up Study on Deaf-Blind (Rubella) Children in California.
ERIC Educational Resources Information Center
Scheffelin, Edward J.
Project Word-Back, an exploratory followup study of 21 young deaf-blind (Rubella) children (6 to 9 years old), was conducted to establish a tentative reference source of information, obtain teacher estimates on selected aspects of the current functioning level of a sample of children, and provide basic data from which hypotheses may be formulated…
Direct phase projection and transcranial focusing of ultrasound for brain therapy.
Pinton, Gianmarco F; Aubry, Jean-Francois; Tanter, Mickaël
2012-06-01
Ultrasound can be used to noninvasively treat the human brain with hyperthermia by focusing through the skull. To obtain an accurate focus, especially at high frequencies (>500 kHz), the phase of the transmitted wave must be modified to correct the aberrations introduced by the patient's individual skull morphology. Currently, three-dimensional finite-difference time-domain simulations are used to model a point source at the target. The outward-propagating wave crosses the measured representation of the human skull and is recorded at the therapy array transducer locations. The signal is then time reversed and experimentally transmitted back to its origin. These simulations are resource intensive and add a significant delay to treatment planning. Ray propagation is computationally efficient because it neglects diffraction and only describes two propagation parameters: the wave's direction and the phase. We propose a minimal method that is based only on the phase. The phase information is projected from the external skull surface to the array locations. This replaces computationally expensive finite-difference computations with an almost instantaneous direct phase projection calculation. For the five human skull samples considered, the phase distribution outside of the skull is shown to vary by less than λ/20 as it propagates over a 5 cm distance and the validity of phase projection is established over these propagation distances. The phase aberration introduced by the skull is characterized and is shown to have a good correspondence with skull morphology. The shape of this aberration is shown to have little variation with propagation distance. The focusing quality with the proposed phase-projection algorithm is shown to be indistinguishable from the gold-standard full finite-difference simulation. In conclusion, a spherical wave that is aberrated by the skull has a phase propagation that can be accurately described as radial, even after it has been distorted. By combining finite-difference simulations with a phase-projection algorithm, the time required for treatment planning is significantly reduced. The correlation length of the phase is used to validate the algorithm and it can also be used to provide guiding parameters for clinical array transducer design in terms of transducer spacing and phase error.
Wang, Liang; Yang, Die; Fang, Cheng; Chen, Zuliang; Lesniewski, Peter J; Mallavarapu, Megharaj; Naidu, Ravendra
2015-01-01
Sodium potassium absorption ratio (SPAR) is an important measure of agricultural water quality, wherein four exchangeable cations (K(+), Na(+), Ca(2+) and Mg(2+)) should be simultaneously determined. An ISE-array is suitable for this application because its simplicity, rapid response characteristics and lower cost. However, cross-interferences caused by the poor selectivity of ISEs need to be overcome using multivariate chemometric methods. In this paper, a solid contact ISE array, based on a Prussian blue modified glassy carbon electrode (PB-GCE), was applied with a novel chemometric strategy. One of the most popular independent component analysis (ICA) methods, the fast fixed-point algorithm for ICA (fastICA), was implemented by the genetic algorithm (geneticICA) to avoid the local maxima problem commonly observed with fastICA. This geneticICA can be implemented as a data preprocessing method to improve the prediction accuracy of the Back-propagation neural network (BPNN). The ISE array system was validated using 20 real irrigation water samples from South Australia, and acceptable prediction accuracies were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saha, K; Barbarits, J; Humenik, R
Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (nmore » = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.« less
Takahashi, Hiro; Honda, Hiroyuki
2006-07-01
Considering the recent advances in and the benefits of DNA microarray technologies, many gene filtering approaches have been employed for the diagnosis and prognosis of diseases. In our previous study, we developed a new filtering method, namely, the projective adaptive resonance theory (PART) filtering method. This method was effective in subclass discrimination. In the PART algorithm, the genes with a low variance in gene expression in either class, not both classes, were selected as important genes for modeling. Based on this concept, we developed novel simple filtering methods such as modified signal-to-noise (S2N') in the present study. The discrimination model constructed using these methods showed higher accuracy with higher reproducibility as compared with many conventional filtering methods, including the t-test, S2N, NSC and SAM. The reproducibility of prediction was evaluated based on the correlation between the sets of U-test p-values on randomly divided datasets. With respect to leukemia, lymphoma and breast cancer, the correlation was high; a difference of >0.13 was obtained by the constructed model by using <50 genes selected by S2N'. Improvement was higher in the smaller genes and such higher correlation was observed when t-test, NSC and SAM were used. These results suggest that these modified methods, such as S2N', have high potential to function as new methods for marker gene selection in cancer diagnosis using DNA microarray data. Software is available upon request.
Marcondes, Freddy Beretta; de Vasconcelos, Rodrigo Antunes; Marchetto, Adriano; de Andrade, André Luis Lugnani; Filho, Américo Zoppi; Etchebehere, Maurício
2015-01-01
Objetctive: Study was to translate and culturally adapt the modified Rowe score for overhead athletes. Methods: The translation and cultural adaptation process initially involved the stages of translation, synthesis, back-translation, and revision by the Translation Group. It was than created the pre-final version of the questionnaire, being the areas “function” and “pain” applied to 20 athletes that perform overhead movements and that suffered SLAP lesions in the dominant shoulder and the areas “active compression test and anterior apprehension test” and “motion” were applied to 15 health professionals. Results: During the translation process there were made little modifications in the questionnaire in order to adapt it to Brazilian culture, without changing the semantics and the idiomatic concept originally described. Conclusion: The questionnaire was easily understood by the subjects of the study, being possible to obtain the Brazilian version of the modified Rowe score for overhead athletes that underwent surgical treatment of the SLAP lesion. PMID:27047903
NASA Astrophysics Data System (ADS)
Pap, Zs.; Mogyorósi, K.; Veréb, G.; Dombi, A.; Hernádi, K.; Danciu, V.; Baia, L.
2014-09-01
As visible light driven photocatalysis became more and more intensively studied, the first commercial products showed up on the market. Simultaneously controversial results appeared in the literature generating an intensive debate regarding the advantages and draw-backs of nitrogen doping of titania. Hence, the present work focuses on two commercially available and four sol-gel made nitrogen modified titania powders regarding their structure and activity. It is demonstrated that the interstitial nitrogen entities “leak out” from the catalysts if the material is irradiated with UV light, while substitutional nitrogen remains stable. However, the latter one was proven to be less important in the photocatalytic point of view. These observations were also valid in the case of sol-gel made nitrogen modified titanias. Furthermore, the results obtained after applying different spectroscopic methods (IR, XPS and DRS) shown that the yellow color of the titanias, does not necessary mean that a successful doping is achieved.
Lee, Heung-Rae
1997-01-01
A three-dimensional image reconstruction method comprises treating the object of interest as a group of elements with a size that is determined by the resolution of the projection data, e.g., as determined by the size of each pixel. One of the projections is used as a reference projection. A fictitious object is arbitrarily defined that is constrained by such reference projection. The method modifies the known structure of the fictitious object by comparing and optimizing its four projections to those of the unknown structure of the real object and continues to iterate until the optimization is limited by the residual sum of background noise. The method is composed of several sub-processes that acquire four projections from the real data and the fictitious object: generate an arbitrary distribution to define the fictitious object, optimize the four projections, generate a new distribution for the fictitious object, and enhance the reconstructed image. The sub-process for the acquisition of the four projections from the input real data is simply the function of acquiring the four projections from the data of the transmitted intensity. The transmitted intensity represents the density distribution, that is, the distribution of absorption coefficients through the object.
Back to the basics: Birmingham, Alabama, measurement and scale
Handley, L.R.; Lockwood, C.M.; Handley, N.
2005-01-01
Back to the Basics: Birmingham, Alabama is the fourth in a series of workshops that focus on teaching foundational map reading and spatial differentiation skills. It is the second published exercise from the Back to the Basics series developed by the Wetland Education through Maps and Aerial Photography (WETMAAP) Program (see Journal of Geography 103, 5: 226-230). Like its predecessor, the current exercise is modified from the Birmingham Back to the Basics workshop offered during the annual National Council for Geographic Education meeting. The focus of this exercise is on scale and measurement, foundational skills for spatial thinking and analysis. ?? 2005 National Council for Geographic Education.
Multisegment nanowire sensors for the detection of DNA molecules.
Wang, Xu; Ozkan, Cengiz S
2008-02-01
We describe a novel application for detecting specific single strand DNA sequences using multisegment nanowires via a straightforward surface functionalization method. Nanowires comprising CdTe-Au-CdTe segments are fabricated using electrochemical deposition, and electrical characterization indicates a p-type behavior for the multisegment nanostructures, in a back-to-back Schottky diode configuration. Such nanostructures modified with thiol-terminated probe DNA fragments could function as high fidelity sensors for biomolecules at very low concentration. The gold segment is utilized for functionalization and binding of single strand DNA (ssDNA) fragments while the CdTe segments at both ends serve to modulate the equilibrium Fermi level of the heterojunction device upon hybridization of the complementary DNA fragments (cDNA) to the ssDNA over the Au segment. Employing such multisegment nanowires could lead to the fabrication more sophisticated and high multispecificity biosensors via selective functionalization of individual segments for biowarfare sensing and medical diagnostics applications.
NASA Technical Reports Server (NTRS)
Volakis, J. L.; Kempel, L. C.; Sliva, R.; Wang, H. T. G.; Woo, A. G.
1994-01-01
The goal of this project was to develop analysis codes for computing the scattering and radiation of antennas on cylindrically and doubly conformal platforms. The finite element-boundary integral (FE-BI) method has been shown to accurately model the scattering and radiation of cavity-backed patch antennas. Unfortunately extension of this rigorous technique to coated or doubly curved platforms is cumbersome and inefficient. An alternative approximate approach is to employ an absorbing boundary condition (ABC) for terminating the finite element mesh thus avoiding use of a Green's function. A FE-ABC method is used to calculate the radar cross section (RCS) and radiation pattern of a cavity-backed patch antenna which is recessed within a metallic surface. It is shown that this approach is accurate for RCS and antenna pattern calculations with an ABC surface displaced as little as 0.3 lambda from the cavity aperture. These patch antennas may have a dielectric overlay which may also be modeled with this technique.
NASA Astrophysics Data System (ADS)
Gusman, A. R.; Satake, K.; Sheehan, A. F.; Mulia, I. E.; Heidarzadeh, M.; Maeda, T.
2015-12-01
Adaption of absolute or differential pressure gauges (APG or DPG) to Ocean Bottom Seismometers has provided the opportunity to study tsunamis. Recently we extracted tsunami waveforms of the 28 October 2012 Haida Gwaii earthquake recoded by the APG and DPG of Cascadia Initiative program (Sheehan et al., 2015, SRL). We applied such dense tsunami observations (48 stations) together with other records from DARTs (9 stations) to characterize the tsunami source. This study is the first study that used such a large number of offshore tsunami records for earthquake source study. Conventionally the curves of tsunami travel times are drawn backward from station locations to estimate the tsunami source region. Here we propose a more advanced technique called tsunami back-projection to estimate the source region. Our image produced by tsunami back-projection has the largest value or tsunami centroid that is very close to the epicenter and above the Queen Charlotte transform fault (QCF), whereas the negative values are mostly located east of Haida Gwaii in the Hecate Strait. By using tsunami back-projection we avoid picking initial tsunami phase which is a necessary step in the conventional method that is rather subjective. The slip distribution of the 2012 Haida Gwaii earthquake estimated by tsunami waveform inversion shows large slip near the trench (4-5 m) and also on a plate interface southeast the epicenter (3-4 m) below QCF. From the slip distribution, the calculated seismic moment is 5.4 × 1020 N m (Mw 7.8). The steep bathymetry offshore Haida Gwaii and the horizontal movement caused by the earthquake possibly affects the sea surface deformation. The potential tsunami energy calculated from the sea-surface deformation of pure faulting is 2.20 × 1013 J, while that from the bathymetry effect is 0.12 × 1013 J or about 5% of the total potential energy. The significant deformation above the steep slope is confirmed by another tsunami inversion that disregards fault parameters.
Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R
2015-01-01
Background In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. Objective The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. Methods From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Results Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. Conclusions A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined workflow and user-friendly interfaces for data collection; (3) allowing for ongoing communication, feedback, and technology-related skill-building among all staff; and (4) supporting infrastructure for back-end data systems. Although mobile technologies are evolving rapidly, lessons learned from these case studies are essential for ensuring that the many benefits of new mobile systems for rapid point-of-sale surveillance are fully realized. PMID:27227138
42 CFR 137.304 - May Self-Governance Tribes buy back environmental services from the IHS?
Code of Federal Regulations, 2010 CFR
2010-10-01
... project agreement, including design and construction engineering, and environmental compliance services... 42 Public Health 1 2010-10-01 2010-10-01 false May Self-Governance Tribes buy back environmental...-GOVERNANCE Construction Nepa Process § 137.304 May Self-Governance Tribes buy back environmental services...
Local meshing plane analysis as a source of information about the gear quality
NASA Astrophysics Data System (ADS)
Mączak, Jędrzej
2013-07-01
In the paper the application of the local meshing plane concept is discussed and applied for detecting of tooth degradation due to fatigue, and for overall gear quality assessment. Knowing the kinematic properties of the machine (i.e. gear tooth numbers) it is possible to modify the diagnostic signal in such a manner that its fragments will be linked to different rotating parts. This allows for presentation of either raw or processed gearbox signal in a form of three dimensional map on the plane "pinion teeth×gear teeth", called local meshing plane. The meshing plane in Cartesian coordinates z1×z2 allows for precise location and assessment of gear faults in terms of meshing quality of consecutive tooth pairs. Although the method was applied to simulated signals generated by the gearbox model, similar results were obtained for the measurement signals recorded during the back-to-back test stand experiment. The described method could be used for assessing the manufacturing quality of gears, the assembly quality as well as for the gear failure evaluation during normal exploitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H; Kong, V; Jin, J
Purpose: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution to this issue is acquiring 2 complimentary projections at each position, which increases scanning time. This study reports our first Result using an inter-projection sensor fusion (IPSF) method to estimate missing projection in our prototype SMOG-based CBCT system. Methods: An in-house SMOG assembling with a 1:1 grid of 3 mm gap has been installed in a CBCT benchtop. The grid movesmore » back and forth in a 3-mm amplitude and up-to 20-Hz frequency. A control program in LabView synchronizes the grid motion with the platform rotation and x-ray firing so that the grid patterns for any two neighboring projections are complimentary. A Catphan was scanned with 360 projections. After scatter correction, the IPSF algorithm was applied to estimate missing signal for each projection using the information from the 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was applied to reconstruct CBCT images. The CBCTs were compared to those reconstructed using normal projections without applying the SMOG system. Results: The SMOG-IPSF method may reduce image dose by half due to the blocked radiation by the grid. The method almost completely removed scatter related artifacts, such as the cupping artifacts. The evaluation of line pair patterns in the CatPhan suggested that the spatial resolution degradation was minimal. Conclusion: The SMOG-IPSF is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.« less
Dose response and structural injury in the disability of spinal injury.
Patel, Mohammed Shakil; Sell, Philip
2013-03-01
In traumatic injury there is a clear relationship between the dose of energy involved, structural tissue damage and resultant disability after recovery. This relationship is often absent in cases of non-specific chronic low back pain that is perceived by patients as attributed to a workplace injury. There are many studies assessing risk factors for non-specific low back pain. However, studies addressing causality of back pain are deficient. To establish whether there exists a causal relationship between structural injury, low back pain and spinal disability. Retrospective analysis of prospectively gathered validated spinal outcome measures [Oswestry disability index (ODI), low back outcome score (LBO), modified somatic perception (MSP), modified Zung depression index (MZD)] between patients with healed high energy thoracolumbar spinal fractures and patients with self-perceived work-related low back pain. Causality was established according to two of Bradford Hill's criteria of medical causality, temporal and dose-response relationships. Twenty-three patients with spinal fractures (group 1) of average age 44 years were compared to 19 patients with self-reported back pain in the workplace pursuing claims for compensation (group 2) of average age 48 years. Both groups were comparable in terms of age and sex. The average ODI in group 1 was 28 % (SD 19) compared to 42 % (SD 19) in group 2 (P < 0.05). Similarly, LBOS was 39.7 versus 24.3 (P < 0.05), MSP 4.3 versus 9.3 (P < 0.05) and MZD 20.2 versus 34.8 (P < 0.05) in groups 1 and 2, respectively. Despite high-energy trauma and significant structural damage to the spine, patients with the high energy injuries had better spinal outcome scores in all measures. There is no 'dose-response' relationship between structural injury, low back pain and spinal disability. This is the reverse of what would be anticipated if structural injury was the cause of disability in workplace reported onset of low back pain.
2011-01-01
Background Various solutions have been introduced for the identification of post-translational modification (PTM) from tandem mass spectrometry (MS/MS) in proteomics field but the identification of peptide modifiers, such as Ubiquitin (Ub) and ubiquitin-like proteins (Ubls), is still a challenge. The fragmentation of peptide modifier produce complex shifted ion mass patterns in combination with other PTMs, which makes it difficult to identify and locate the PTMs on a protein sequence. Currently, most PTM identification methods do not consider the complex fragmentation of peptide modifier or deals it separately from the other PTMs. Results We developed an advanced PTM identification method that inspects possible ion patterns of the most known peptide modifiers as well as other known biological and chemical PTMs to make more comprehensive and accurate conclusion. The proposed method searches all detectable mass differences of measured peaks from their theoretical values and the mass differences within mass tolerance range are grouped as mass shift classes. The most possible locations of multiple PTMs including peptide modifiers can be determined by evaluating all possible scenarios generated by the combination of the qualified mass shift classes.The proposed method showed excellent performance in the test with simulated spectra having various PTMs including peptide modifiers and in the comparison with recently developed methods such as QuickMod and SUMmOn. In the analysis of HUPO Brain Proteome Project (BPP) datasets, the proposed method could find the ubiquitin modification sites that were not identified by other conventional methods. Conclusions This work presents a novel method for identifying bothpeptide modifiers that generate complex fragmentation patternsand PTMs that are not fragmented during fragmentation processfrom tandem mass spectra. PMID:22373085
Tham, Leung-Mun; Lee, Heow Pueh; Lu, Chun
2007-07-01
We evaluated the effectiveness of modified lithotriptor shock waves using computer models. Finite element models were used to simulate the propagation of lithotriptor shock waves in human renal calculi in vivo. Kidney stones were assumed to be spherical, homogeneous, isotropic and linearly elastic, and immersed in a continuum fluid. Single and tandem shock wave pulses modified to intensify the collapse of cavitation bubbles near the stone surface to increase fragmentation efficiency and suppress the expansion of intraluminal bubbles for decreased vascular injury were analyzed. The effectiveness of the modified shock waves was assessed by comparing the states of loading in the renal calculi induced by these shock waves to those produced by conventional shock waves. Our numerical simulations revealed that modified shock waves produced marginally lower stresses in spherical renal calculi than those produced by conventional shock waves. Tandem pulses of conventional or modified shock waves produced peak stresses in the front and back halves of the renal calculi. However, the single shock wave pulses generated significant peak stresses in only the back halves of the renal calculi. Our numerical simulations suggest that for direct stress wave induced fragmentation modified shock waves should be as effective as conventional shock waves for fragmenting kidney stones. Also, with a small interval of 20 microseconds between the pulses tandem pulse lithotripsy using modified or conventional shock waves could be considerably more effective than single pulse lithotripsy for fragmenting kidney stones.
3D refractive index measurements of special optical fibers
NASA Astrophysics Data System (ADS)
Yan, Cheng; Huang, Su-Juan; Miao, Zhuang; Chang, Zheng; Zeng, Jun-Zhang; Wang, Ting-Yun
2016-09-01
A digital holographic microscopic chromatography-based approach with considerably improved accuracy, simplified configuration and performance stability is proposed to measure three dimensional refractive index of special optical fibers. Based on the approach, a measurement system is established incorporating a modified Mach-Zehnder interferometer and lab-developed supporting software for data processing. In the system, a phase projection distribution of an optical fiber is utilized to obtain an optimal digital hologram recorded by a CCD, and then an angular spectrum theory-based algorithm is adopted to extract the phase distribution information of an object wave. The rotation of the optic fiber enables the experimental measurements of multi-angle phase information. Based on the filtered back projection algorithm, a 3D refraction index of the optical fiber is thus obtained at high accuracy. To evaluate the proposed approach, both PANDA fibers and special elliptical optical fiber are considered in the system. The results measured in PANDA fibers agree well with those measured using S14 Refractive Index Profiler, which is, however, not suitable for measuring the property of a special elliptical fiber.
Ashton-Warner Literacy Method. Technical Note No. 5.
ERIC Educational Resources Information Center
Gunter, Jock
This document describes a literacy project in rural Ecuador using a modified version of Sylvia Ashton Warner's language experience approach. This method allows learners to approach written culture on their own terms by learning words important to their life, then transferring these works to sentences and stories. The approach reduces the rural…
Kent, Alexander Dale [Los Alamos, NM
2008-09-02
Methods and systems in a data/computer network for authenticating identifying data transmitted from a client to a server through use of a gateway interface system which are communicately coupled to each other are disclosed. An authentication packet transmitted from a client to a server of the data network is intercepted by the interface, wherein the authentication packet is encrypted with a one-time password for transmission from the client to the server. The one-time password associated with the authentication packet can be verified utilizing a one-time password token system. The authentication packet can then be modified for acceptance by the server, wherein the response packet generated by the server is thereafter intercepted, verified and modified for transmission back to the client in a similar but reverse process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennock, Kenneth; Makarov, Yuri V.; Rajagopal, Sankaran
The need for proactive closed-loop integration of uncertainty information into system operations and probability-based controls is widely recognized, but rarely implemented in system operations. Proactive integration for this project means that the information concerning expected uncertainty ranges for net load and balancing requirements, including required balancing capacity, ramping and ramp duration characteristics, will be fed back into the generation commitment and dispatch algorithms to modify their performance so that potential shortages of these characteristics can be prevented. This basic, yet important, premise is the motivating factor for this project. The achieved project goal is to demonstrate the benefit of suchmore » a system. The project quantifies future uncertainties, predicts additional system balancing needs including the prediction intervals for capacity and ramping requirements of future dispatch intervals, evaluates the impacts of uncertainties on transmission including the risk of overloads and voltage problems, and explores opportunities for intra-hour generation adjustments helping to provide more flexibility for system operators. The resulting benefits culminate in more reliable grid operation in the face of increased system uncertainty and variability caused by solar power. The project identifies that solar power does not require special separate penetration level restrictions or penalization for its intermittency. Ultimately, the collective consideration of all sources of intermittency distributed over a wide area unified with the comprehensive evaluation of various elements of balancing process, i.e. capacity, ramping, and energy requirements, help system operators more robustly and effectively balance generation against load and interchange. This project showed that doing so can facilitate more solar and other renewable resources on the grid without compromising reliability and control performance. Efforts during the project included developing and integrating advanced probabilistic solar forecasts, including distributed PV forecasts, into closed –loop decision making processes. Additionally, new uncertainty quantifications methods and tools for the direct integration of uncertainty and variability information into grid operations at the transmission and distribution levels were developed and tested. During Phase 1, project work focused heavily on the design, development and demonstration of a set of processes and tools that could reliably and efficiently incorporate solar power into California’s grid operations. In Phase 2, connectivity between the ramping analysis tools and market applications software were completed, multiple dispatch scenarios demonstrated a successful reduction of overall uncertainty and an analysis to quantify increases in system operator reliability, and the transmission and distribution system uncertainty prediction tool was introduced to system operation engineers in a live webinar. The project met its goals, the experiments prove the advancements to methods and tools, when working together, are beneficial to not only the California Independent System Operator, but the benefits are transferable to other system operators in the United States.« less
Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers.
Valstar, E R; Spoor, C W; Nelissen, R G; Rozing, P M
1997-11-01
A method for the detection of micromotion of a metal-backed hemispherical acetabular cup is presented and tested. Unlike in conventional roentgen stereophotogrammetric analysis, the cup does not have to be marked with tantalum markers; the micromotion is calculated from the contours of the hemispherical part and the base circle of the cup. In this way, two rotations (tilt and anteversion) and the translations along the three cardinal axes are obtained. In a phantom study, the maximum error in the position of the cup's centre was 0.04 mm. The mean error in the orientation of the cup was 0.41 degree, with a 95% confidence interval of 0.28-0.54 degree. The in vivo accuracy was tested by repeated measurement of 21 radiographs from seven patients. The upper bound of the 95% tolerance interval for the translations along the transversal, longitudinal, and sagittal axes was 0.09, 0.07, and 0.34 mm, respectively: for the rotation, this upper bound was 0.39 degree. These results show that the new method, in which the position and orientation of metal-backed hemispherical cup is calculated from its projected contours, is a simple and accurate alternative to attaching markers to the cup.
NASA Astrophysics Data System (ADS)
Ee, K. C.; Dillon, O. W.; Jawahir, I. S.
2004-06-01
This paper discusses the influence of major chip-groove parameters of a cutting tool on the chip formation process in orthogonal machining using finite element (FE) methods. In the FE formulation, a thermal elastic-viscoplastic material model is used together with a modified Johnson-Cook material law for the flow stress. The chip back-flow angle and the chip up-curl radius are calculated for a range of cutting conditions by varying the chip-groove parameters. The analysis provides greater understanding of the effectiveness of chip-groove configurations and points a way to correlate cutting conditions with tool-wear when machining with a grooved cutting tool.
Tamrin, Shamsul Bahri Mohd; Yokoyama, Kazuhito; Jalaludin, Juliana; Aziz, Nasaruddin Abdul; Jemoin, Nizam; Nordin, Rusli; Li Naing, Ayub; Abdullah, Yunus; Abdullah, Mazlan
2007-04-01
To determine the risk factors associated with complain of low back pain. A cross sectional study was done from June 2004 until August 2005. Seven hundred and sixty commercial vehicle drivers from 11 bus companies in central, northern and eastern regions in Malaysia participated in this study. Modified Nordic questionnaire was used to determine the prevalence of low back pain; Maestro human vibration meter was used to measure the personal R.M.S values of lateral, anterior-posterior and vertical axes. Modified Owas was used to assess the awkward posture of the driver torso namely, bending forward movement, leaning, sitting straight and twisting. Profile of Mood States (POMS) was used to evaluate the mood states of bus drivers with complain of low back pain. A high prevalence of low back pain (60.4%) among Malaysian commercial vehicle drivers was found. Logistic regression analysis controlling for age, income, education level and non occupational activities revealed that the following factors were related to low back pain: Tension-anxiety [1.080, 95% CI 1.041-1.121], depression dejection [1.047, 95% CI 1.023-1.072], anger-hostility [1.053, 95% CI 1.027-1.081], fatigue [1.132, 95% CI 1.089-1.177] and confusion [1.114, 95% CI 1.061-1.169] of POMS, length of employment [1.001, 95% CI 1.0-1.003], steering wheel adjustment [1.521, 95% CI 1.101-2.101], perception of exposing to vibration [1.943, 95% CI 1.389-2.719]. In conclusion, combinations of risks lead to high increase of low back pain complain among Malaysian bus drivers.
Reviving Polya's "Look Back" in a Singapore School
ERIC Educational Resources Information Center
Leong, Yew Hoong; Tay, Eng Guan; Toh, Tin Lam; Quek, Khiok Seng; Dindyal, Jaguthsing
2011-01-01
This study is based on the stance that Polya's "Look Back," though understudied, remains relevant to Mathematics curricula that place emphasis on problem solving. Although the Singapore Mathematics curriculum adopts the goal of teaching Look Back, research about how it is carried out in actual classroom practice is rare. In our project,…
Record Efficiency on Large Area P-Type Czochralski Silicon Substrates
NASA Astrophysics Data System (ADS)
Hallam, Brett; Wenham, Stuart; Lee, Haeseok; Lee, Eunjoo; Lee, Hyunwoo; Kim, Jisun; Shin, Jeongeun; Cho, Kyeongyeon; Kim, Jisoo
2012-10-01
In this work we report a world record independently confirmed efficiency of 19.4% for a large area p-type Czochralski grown solar cell fabricated with a full area aluminium back surface field. This is achieved using the laser doped selective emitter solar cell technology on an industrial screen print production line with the addition of laser doping and light induced plating equipment. The use of a modified diffusion process is explored in which the emitter is diffused to a sheet resistance of 90 Ω/square and subsequent etch back of the emitter to 120 Ω/square. This results in a lower surface concentration of phosphorus compared to that of emitters diffused directly to 120 Ω/square. This modified diffusion process subsequently reduces the conductivity of the surface in relation to that of the heavily diffused laser doped contacts and avoids parasitic plating, resulting an average absolute increase in efficiency of 0.4% compared to cells fabricated without an emitter etch back process.
a Framework for Distributed Mixed Language Scientific Applications
NASA Astrophysics Data System (ADS)
Quarrie, D. R.
The Object Management Group has defined an architecture (CORBA) for distributed object applications based on an Object Request Broker and Interface Definition Language. This project builds upon this architecture to establish a framework for the creation of mixed language scientific applications. A prototype compiler has been written that generates FORTRAN 90 or Eiffel stubs and skeletons and the required C++ glue code from an input IDL file that specifies object interfaces. This generated code can be used directly for non-distributed mixed language applications or in conjunction with the C++ code generated from a commercial IDL compiler for distributed applications. A feasibility study is presently underway to see whether a fully integrated software development environment for distributed, mixed-language applications can be created by modifying the back-end code generator of a commercial CASE tool to emit IDL.
An evaluation of gap-filled Landsat SLC-off imagery for wildland fire burn severity mapping
Howard, Stephen M.; Lacasse, James M.
2004-01-01
n May 31, 2003 unusual artifacts appeared within image data collected by the Enhanced Thematic Mapper plus (ETM+) instrument on-board the Landsat 7 spacecraft. The U.S. Geological Survey (USGS), with the support of NASA, has been working to find a means of compensating for the data gaps that result from a failure of the instrument’s scan line corrector (SLC). The SLC is an electromechanical device that compensates for the forward motion of the spacecraft by modifying the instrument’s optical path. The problem is likely due to a mechanical failure of the device for which there is no redundancy and that cannot be repaired or coaxed back into service. Further information regarding Landsat 7 and the SLC failure can be found at the Landsat Project home page (http://landsat7.usgs.gov).
NASA Astrophysics Data System (ADS)
Prijono, Agus; Darmawan Hangkawidjaja, Aan; Ratnadewi; Saleh Ahmar, Ansari
2018-01-01
The verification to person who is used today as a fingerprint, signature, personal identification number (PIN) in the bank system, identity cards, attendance, easily copied and forged. This causes the system not secure and is vulnerable to unauthorized persons to access the system. In this research will be implemented verification system using the image of the blood vessels in the back of the palms as recognition more difficult to imitate because it is located inside the human body so it is safer to use. The blood vessels located at the back of the human hand is unique, even humans twins have a different image of the blood vessels. Besides the image of the blood vessels do not depend on a person’s age, so it can be used for long term, except in the case of an accident, or disease. Because of the unique vein pattern recognition can be used in a person. In this paper, we used a modification method to perform the introduction of a person based on the image of the blood vessel that is using Modified Local Line Binary Pattern (MLLBP). The process of matching blood vessel image feature extraction using Hamming Distance. Test case of verification is done by calculating the percentage of acceptance of the same person. Rejection error occurs if a person was not matched by the system with the data itself. The 10 person with 15 image compared to 5 image vein for each person is resulted 80,67% successful Another test case of the verification is done by verified two image from different person that is forgery, and the verification will be true if the system can rejection the image forgery. The ten different person is not verified and the result is obtained 94%.
PCB-Caulk Replacement Project Johnson Space Center Houston, TX
NASA Technical Reports Server (NTRS)
Young, William M.; Stanch, Penney M.; Molenda, William
2011-01-01
Wet method reduced exposure by minimizing overall respirable particulate release. Dry method didn't introduce delays for primer/caulk application. Removed caulks came in many forms, from dry powdery to tarry sticky. Varying textures were not sampled or packaged differently. During the course of the project, EPA modified recommended practices to include full containment for exterior caulk removal. Changes are ongoing. Initial recommendations were directed to school buildings. EPA is researching risks due to caulk. Exposure guidance lacking except for 2 of 209 PCB congeners. Work was safely completed on schedule and under budget.
Assessing musculoskeletal disorders among municipal waste loaders of Mumbai, India.
Salve, Pradeep; Chokhandre, Praveen; Bansod, Dhananjay
2017-10-06
The study aims to assess the impact of municipal waste loading occupation upon developing musculoskeletal disorders (MSDs) and thereby disabilities among waste loaders. Additionally, the study has identified the potential risk factors raising MSDs and disabilities. A cross-sectional case-control design survey was conducted in 6 out of 24 municipal wards of Mumbai during March-September 2015. The study population consisted of municipal waste loaders (N = 180) and a control group (N = 180). The Standardized Modified Nordic questionnaire was adopted to measures the MSDs and thereby disabilities in the past 12 months. A Propensity Score Matching (PSM) method was applied to assess the impact of waste loading occupation on developing MSDs and disabilities. Waste loaders had a significantly higher risk of developing MSDs as well as disabilities than the control group particularly for low back, hip/ thigh upper back and shoulder. Propensity Score Matching results revealed that the MSDs were significantly higher among waste loaders for hip/thigh (22%), low back (19%), shoulder (18%), and upper back (15%) than matched control group. Likewise, MSDs-related disabilities were found to be significantly higher among waste loaders for low back (20%), hip/ thigh (18%) upper back (13%) and shoulder (8%) than the control group. Duration of work, substance use and mental health were found to be the potential psychosocial factors for developing the risk of MSDs and disabilities. The municipal waste loading occupation raised the risk of MSDs and related disabilities among waste loaders compared to the control group. The preventive and curative measures are strongly recommended to minimize the burden of MSDs and disabilities. Int J Occup Med Environ Health 2017;30(6):875-886. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
2008-01-01
Objectives To determine whether advice and training on working techniques and lifting equipment prevent back pain in jobs that involve heavy lifting. Data sources Medline, Embase, CENTRAL, Cochrane Back Group’s specialised register, CINAHL, Nioshtic, CISdoc, Science Citation Index, and PsychLIT were searched up to September-November 2005. Review methods The primary search focused on randomised controlled trials and the secondary search on cohort studies with a concurrent control group. Interventions aimed to modify techniques for lifting and handling heavy objects or patients and including measurements for back pain, consequent disability, or sick leave as the main outcome were considered for the review. Two authors independently assessed eligibility of the studies and methodological quality of those included. For data synthesis, we summarised the results of studies comparing similar interventions. We used odds ratios and effect sizes to combine the results in a meta-analysis. Finally, we compared the conclusions of the primary and secondary analyses. Results Six randomised trials and five cohort studies met the inclusion criteria. Two randomised trials and all cohort studies were labelled as high quality. Eight studies looked at lifting and moving patients, and three studies were conducted among baggage handlers or postal workers. Those in control groups received no intervention or minimal training, physical exercise, or use of back belts. None of the comparisons in randomised trials (17 720 participants) yielded significant differences. In the secondary analysis, none of the cohort studies (772 participants) had significant results, which supports the results of the randomised trials. Conclusions There is no evidence to support use of advice or training in working techniques with or without lifting equipment for preventing back pain or consequent disability. The findings challenge current widespread practice of advising workers on correct lifting technique. PMID:18244957
Influence of Installation Errors On the Output Data of the Piezoelectric Vibrations Transducers
NASA Astrophysics Data System (ADS)
Kozuch, Barbara; Chelmecki, Jaroslaw; Tatara, Tadeusz
2017-10-01
The paper examines an influence of installation errors of the piezoelectric vibrations transducers on the output data. PCB Piezotronics piezoelectric accelerometers were used to perform calibrations by comparison. The measurements were performed with TMS 9155 Calibration Workstation version 5.4.0 at frequency in the range of 5Hz - 2000Hz. Accelerometers were fixed on the calibration station in a so-called back-to-back configuration in accordance with the applicable international standard - ISO 16063-21: Methods for the calibration of vibration and shock transducers - Part 21: Vibration calibration by comparison to a reference transducer. The first accelerometer was calibrated by suitable methods with traceability to a primary reference transducer. Each subsequent calibration was performed when changing one setting in relation to the original calibration. The alterations were related to negligence and failures in relation to the above-mentioned standards and operating guidelines - e.g. the sensor was not tightened or appropriate substance was not placed. Also, there was modified the method of connection which was in the standards requirements. Different kind of wax, light oil, grease and other assembly methods were used. The aim of the study was to verify the significance of standards requirements and to estimate of their validity. The authors also wanted to highlight the most significant calibration errors. Moreover, relation between various appropriate methods of the connection was demonstrated.
Olson, R; Hahn, D I; Buckert, A
2009-06-01
Short-haul truck (lorry) drivers are particularly vulnerable to back pain and injury due to exposure to whole body vibration, prolonged sitting and demanding material handling tasks. The current project reports the results of video-based assessments (711 stops) and driver behavioural self-monitoring (BSM) (385 stops) of injury hazards during non-driving work. Participants (n = 3) worked in a trailer fitted with a camera system during baseline and BSM phases. Descriptive analyses showed that challenging customer environments and non-standard ingress/egress were prevalent. Statistical modelling of video-assessment results showed that each instance of manual material handling increased the predicted mean for severe trunk postures by 7%, while customer use of a forklift, moving standard pallets and moving non-standard pallets decreased predicted means by 12%, 20% and 22% respectively. Video and BSM comparisons showed that drivers were accurate at self-monitoring frequent environmental conditions, but less accurate at monitoring trunk postures and rare work events. The current study identified four predictors of severe trunk postures that can be modified to reduce risk of injury among truck drivers and showed that workers can produce reliable self-assessment data with BSM methods for frequent and easily discriminated events environmental.
Lee, H.R.
1997-11-18
A three-dimensional image reconstruction method comprises treating the object of interest as a group of elements with a size that is determined by the resolution of the projection data, e.g., as determined by the size of each pixel. One of the projections is used as a reference projection. A fictitious object is arbitrarily defined that is constrained by such reference projection. The method modifies the known structure of the fictitious object by comparing and optimizing its four projections to those of the unknown structure of the real object and continues to iterate until the optimization is limited by the residual sum of background noise. The method is composed of several sub-processes that acquire four projections from the real data and the fictitious object: generate an arbitrary distribution to define the fictitious object, optimize the four projections, generate a new distribution for the fictitious object, and enhance the reconstructed image. The sub-process for the acquisition of the four projections from the input real data is simply the function of acquiring the four projections from the data of the transmitted intensity. The transmitted intensity represents the density distribution, that is, the distribution of absorption coefficients through the object. 5 figs.
Marich, Andrej V; Lanier, Vanessa M; Salsich, Gretchen B; Lang, Catherine E; Van Dillen, Linda R
2018-04-06
People with low back pain (LBP) may display an altered lumbar movement pattern of early lumbar motion compared to people with healthy backs. Modifying this movement pattern during a clinical test decreases pain. It is unknown whether similar effects would be seen during a functional activity. The objective of this study is was to examine the lumbar movement patterns before and after motor skill training, effects on pain, and characteristics that influenced the ability to modify movement patterns. The design consisted of a repeated-measures study examining early-phase lumbar excursion in people with LBP during a functional activity test. Twenty-six people with chronic LBP received motor skill training, and 16 people with healthy backs were recruited as a reference standard. Twenty minutes of motor skill training to decrease early-phase lumbar excursion during the performance of a functional activity were used as a treatment intervention. Early-phase lumbar excursion was measured before and after training. Participants verbally reported increased pain, decreased pain, or no change in pain during performance of the functional activity test movement in relation to their baseline pain. The characteristics of people with LBP that influenced the ability to decrease early-phase lumbar excursion were examined. People with LBP displayed greater early-phase lumbar excursion before training than people with healthy backs (LBP: mean = 11.2°, 95% CI = 9.3°-13.1°; healthy backs: mean = 7.1°, 95% CI = 5.8°-8.4°). Following training, the LBP group showed a decrease in the amount of early-phase lumbar excursion (mean change = 4.1°, 95% CI = 2.4°-5.8°); 91% of people with LBP reported that their pain decreased from baseline following training. The longer the duration of LBP (β = - 0.22) and the more early-phase lumbar excursion before training (β = - 0.82), the greater the change in early-phase lumbar excursion following training. The long-term implications of modifying the movement pattern and whether the decrease in pain attained was clinically significant are unknown. People with LBP were able to modify their lumbar movement pattern and decrease their pain with the movement pattern within a single session of motor skill training.
Friche, Amélia Augusta de Lima; Dias, Maria Angélica de Salles; Reis, Priscila Brandão Dos; Dias, Cláudia Silva; Caiaffa, Waleska Teixeira
2015-11-01
There is little scientific evidence that urban upgrading helps improve health or reduce inequities. This article presents the design for the BH-Viva Project, a "quasi-experimental", multiphase, mixed-methods study with quantitative and qualitative components, proposing an analytical model for monitoring the effects that interventions in the urban environment can have on residents' health in slums in Belo Horizonte, Minas Gerais State, Brazil. A preliminary analysis revealed intra-urban differences in age-specific mortality when comparing areas with and without interventions; the mortality rate from 2002 to 2012 was stable in the "formal city", increased in slums without interventions, and decreased in slums with interventions. BH-Viva represents an effort at advancing methodological issues, providing learning and theoretical backing for urban health research and research methods, allowing their application and extension to other urban contexts.
Engineering calculations for communications satellite systems planning
NASA Technical Reports Server (NTRS)
Walton, E.; Aebker, E.; Mata, F.; Reilly, C.
1991-01-01
The final phase of a satellite synthesis project is described. Several methods for generating satellite positionings with improved aggregate carrier to interference characteristics were studied. Two general methods for modifying required separation values are presented. Also, two methods for improving aggregate carrier to interference (C/I) performance of given satellite synthesis solutions are presented. A perturbation of the World Administrative Radio Conference (WARC) synthesis is presented.
42 CFR 137.304 - May Self-Governance Tribes buy back environmental services from the IHS?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false May Self-Governance Tribes buy back environmental...-GOVERNANCE Construction Nepa Process § 137.304 May Self-Governance Tribes buy back environmental services from the IHS? Yes, Self-Governance Tribes may “buy back” project related services in their construction...
NASA Astrophysics Data System (ADS)
Rahmatullah; Ellahi, Rahmat; Mohyud-Din, Syed Tauseef; Khan, Umar
2018-03-01
We have computed new exact traveling wave solutions, including complex solutions of fractional order Boussinesq-Like equations, occurring in physical sciences and engineering, by applying Exp-function method. The method is blended with fractional complex transformation and modified Riemann-Liouville fractional order operator. Our obtained solutions are verified by substituting back into their corresponding equations. To the best of our knowledge, no other technique has been reported to cope with the said fractional order nonlinear problems combined with variety of exact solutions. Graphically, fractional order solution curves are shown to be strongly related to each other and most importantly, tend to fixate on their integer order solution curve. Our solutions comprise high frequencies and very small amplitude of the wave responses.
NASA Technical Reports Server (NTRS)
Willis, P. B.; Baum, B.; White, R. A.
1978-01-01
The results of an investigation of solar module encapsulation systems applicable to the Low-Cost Solar Array Project 1986 cost and performance goals are presented. Six basic construction elements were identified and their specific uses in module construction defined. A uniform coating basis was established for each element. The survey results were also useful in revealing price ranges for classes of materials and estimating the cost allocation for each element within the encapsulating cost goal. The six construction elements were considered to be substrates, superstrates, pottants, adhesives, outer covers and back covers.
NASA Astrophysics Data System (ADS)
Laura, Jason; Skinner, James A.; Hunter, Marc A.
2017-08-01
In this paper we present the Large Crater Clustering (LCC) tool set, an ArcGIS plugin that supports the quantitative approximation of a primary impact location from user-identified locations of possible secondary impact craters or the long-axes of clustered secondary craters. The identification of primary impact craters directly supports planetary geologic mapping and topical science studies where the chronostratigraphic age of some geologic units may be known, but more distant features have questionable geologic ages. Previous works (e.g., McEwen et al., 2005; Dundas and McEwen, 2007) have shown that the source of secondary impact craters can be estimated from secondary impact craters. This work adapts those methods into a statistically robust tool set. We describe the four individual tools within the LCC tool set to support: (1) processing individually digitized point observations (craters), (2) estimating the directional distribution of a clustered set of craters, back projecting the potential flight paths (crater clusters or linearly approximated catenae or lineaments), (3) intersecting projected paths, and (4) intersecting back-projected trajectories to approximate the local of potential source primary craters. We present two case studies using secondary impact features mapped in two regions of Mars. We demonstrate that the tool is able to quantitatively identify primary impacts and supports the improved qualitative interpretation of potential secondary crater flight trajectories.
Image reconstruction of x-ray tomography by using image J platform
NASA Astrophysics Data System (ADS)
Zain, R. M.; Razali, A. M.; Salleh, K. A. M.; Yahya, R.
2017-01-01
A tomogram is a technical term for a CT image. It is also called a slice because it corresponds to what the object being scanned would look like if it were sliced open along a plane. A CT slice corresponds to a certain thickness of the object being scanned. So, while a typical digital image is composed of pixels, a CT slice image is composed of voxels (volume elements). In the case of x-ray tomography, similar to x-ray Radiography, the quantity being imaged is the distribution of the attenuation coefficient μ(x) within the object of interest. The different is only on the technique to produce the tomogram. The image of x-ray radiography can be produced straight foward after exposed to x-ray, while the image of tomography produces by combination of radiography images in every angle of projection. A number of image reconstruction methods by converting x-ray attenuation data into a tomography image have been produced by researchers. In this work, Ramp filter in "filtered back projection" has been applied. The linear data acquired at each angular orientation are convolved with a specially designed filter and then back projected across a pixel field at the same angle. This paper describe the step of using Image J software to produce image reconstruction of x-ray tomography.
NASA Technical Reports Server (NTRS)
Goldman, H.; Wolf, M.
1979-01-01
The manufacturing methods for photovoltaic solar energy utilization are assessed. Economic and technical data on the current front junction formation processes of gaseous diffusion and ion implantation are presented. Future proposals, including modifying gaseous diffusion and using ion implantation, to decrease the cost of junction formation are studied. Technology developments in current processes and an economic evaluation of the processes are included.
New developments in EPID-based 3D dosimetry in The Netherlands Cancer Institute
NASA Astrophysics Data System (ADS)
Mijnheer, B.; Rozendaal, R.; Olaciregui-Ruiz, I.; González, P.; van Oers, R.; Mans, A.
2017-05-01
EPID-based offline 3D in vivo dosimetry is performed routinely in The Netherlands Cancer Institute for almost all RT treatments. The 3D dose distribution is reconstructed using the EPID primary dose in combination with a back-projection algorithm and compared with the planned dose distribution. Recently the method was adapted for real-time dose verification, performing 3D dose verification in less than 300 ms, which is faster than the current portal frame acquisition rate. In this way a possibility is created for halting the linac in case of large delivery errors. Furthermore, a new method for pre-treatment QA was developed in which the EPID primary dose behind a phantom or patient is predicted using the CT data of that phantom or patient in combination with in-air EPID measurements. This virtual EPID primary transit dose is then used to reconstruct the 3D dose distribution within the phantom or patient geometry using the same dose engine as applied offline. In order to assess the relevance of our clinically applied alert criteria, we investigated the sensitivity of our EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. This was done through simulation by modifying patient treatment plans, as well as experimentally by performing EPID measurements during the irradiation of an Alderson phantom, both after deliberately introducing errors during VMAT delivery. In this presentation these new developments will be elucidated.
Ant Colony Optimization Analysis on Overall Stability of High Arch Dam Basis of Field Monitoring
Liu, Xiaoli; Chen, Hong-Xin; Kim, Jinxie
2014-01-01
A dam ant colony optimization (D-ACO) analysis of the overall stability of high arch dams on complicated foundations is presented in this paper. A modified ant colony optimization (ACO) model is proposed for obtaining dam concrete and rock mechanical parameters. A typical dam parameter feedback problem is proposed for nonlinear back-analysis numerical model based on field monitoring deformation and ACO. The basic principle of the proposed model is the establishment of the objective function of optimizing real concrete and rock mechanical parameter. The feedback analysis is then implemented with a modified ant colony algorithm. The algorithm performance is satisfactory, and the accuracy is verified. The m groups of feedback parameters, used to run a nonlinear FEM code, and the displacement and stress distribution are discussed. A feedback analysis of the deformation of the Lijiaxia arch dam and based on the modified ant colony optimization method is also conducted. By considering various material parameters obtained using different analysis methods, comparative analyses were conducted on dam displacements, stress distribution characteristics, and overall dam stability. The comparison results show that the proposal model can effectively solve for feedback multiple parameters of dam concrete and rock material and basically satisfy assessment requirements for geotechnical structural engineering discipline. PMID:25025089
Marine geophysical data collected in a shallow back-barrier estuary, Barnegat Bay, New Jersey
Andrews, Brian D.; Miselis, Jennifer L.; Danforth, William W.; Irwin, Barry J.; Worley, Charles R.; Bergeron, Emile M.; Blackwood, Dann S.
2015-06-26
In 2011, the U.S. Geological Survey, in cooperation with the New Jersey Department of Environmental Protection, began a multidisciplinary research project to better understand the water quality in Barnegat Bay, New Jersey. This back-barrier estuary is experiencing degraded water quality, algal blooms, loss of seagrass, and increases in oxygen stress, macroalgae, stinging nettles, and brown tide. The spatial scale of the estuary and the scope of challenges within it necessitate a multidisciplinary approach that includes establishing the regional geology and the estuary’s physical characteristics and modeling how the estuary’s morphology interacts to affect its water quality. This report presents the data collected during this project for use in understanding the morphology and the distribution of sea-floor and sub-sea-floor sediments within Barnegat Bay, describes the methods used to collect and process those data, and includes links to the final processed datasets. These data can be used by scientists to understand the links between geomorphology, geologic framework, sediment transport, and estuarine water quality and circulation.
Regridding reconstruction algorithm for real-time tomographic imaging
Marone, F.; Stampanoni, M.
2012-01-01
Sub-second temporal-resolution tomographic microscopy is becoming a reality at third-generation synchrotron sources. Efficient data handling and post-processing is, however, difficult when the data rates are close to 10 GB s−1. This bottleneck still hinders exploitation of the full potential inherent in the ultrafast acquisition speed. In this paper the fast reconstruction algorithm gridrec, highly optimized for conventional CPU technology, is presented. It is shown that gridrec is a valuable alternative to standard filtered back-projection routines, despite being based on the Fourier transform method. In fact, the regridding procedure used for resampling the Fourier space from polar to Cartesian coordinates couples excellent performance with negligible accuracy degradation. The stronger dependence of the observed signal-to-noise ratio for gridrec reconstructions on the number of angular views makes the presented algorithm even superior to filtered back-projection when the tomographic problem is well sampled. Gridrec not only guarantees high-quality results but it provides up to 20-fold performance increase, making real-time monitoring of the sub-second acquisition process a reality. PMID:23093766
NASA Astrophysics Data System (ADS)
Gómez-Alba, Sebastián; Fajardo-Zarate, Carlos Eduardo; Vargas, Carlos Alberto
2016-11-01
At least 156 earthquakes (Mw 2.8-4.4) were detected in Puerto Gaitán, Colombia (Eastern Llanos Basin) between April 2013 and December 2014. Out of context, this figure is not surprising. However, from its inception in 1993, the Colombian National Seismological Network (CNSN) found no evidence of significant seismic events in this region. In this study, we used CNSN data to model the rupture front and orientation of the highest-energy events. For these earthquakes, we relied on a joint inversion method to estimate focal mechanisms and, in turn, determine the area's fault trends and stress tensor. While the stress tensor defines maximum stress with normal tendency, focal mechanisms generally represent normal faults with NW orientation, an orientation which lines up with the tracking rupture achieved via Back Projection Imaging for the study area. We ought to bear in mind that this anomalous earthquake activity has taken place within oil fields. In short, the present paper argues that, based on the spatiotemporal distribution of seismic events, hydrocarbon operations may induce the study area's seismicity.
2.5D S-wave velocity model of the TESZ area in northern Poland from receiver function analysis
NASA Astrophysics Data System (ADS)
Wilde-Piorko, Monika; Polkowski, Marcin; Grad, Marek
2016-04-01
Receiver function (RF) locally provides the signature of sharp seismic discontinuities and information about the shear wave (S-wave) velocity distribution beneath the seismic station. The data recorded by "13 BB Star" broadband seismic stations (Grad et al., 2015) and by few PASSEQ broadband seismic stations (Wilde-Piórko et al., 2008) are analysed to investigate the crustal and upper mantle structure in the Trans-European Suture Zone (TESZ) in northern Poland. The TESZ is one of the most prominent suture zones in Europe separating the young Palaeozoic platform from the much older Precambrian East European craton. Compilation of over thirty deep seismic refraction and wide angle reflection profiles, vertical seismic profiling in over one hundred thousand boreholes and magnetic, gravity, magnetotelluric and thermal methods allowed for creation a high-resolution 3D P-wave velocity model down to 60 km depth in the area of Poland (Grad et al. 2016). On the other hand the receiver function methods give an opportunity for creation the S-wave velocity model. Modified ray-tracing method (Langston, 1977) are used to calculate the response of the structure with dipping interfaces to the incoming plane wave with fixed slowness and back-azimuth. 3D P-wave velocity model are interpolated to 2.5D P-wave velocity model beneath each seismic station and synthetic back-azimuthal sections of receiver function are calculated for different Vp/Vs ratio. Densities are calculated with combined formulas of Berteussen (1977) and Gardner et al. (1974). Next, the synthetic back-azimuthal sections of RF are compared with observed back-azimuthal sections of RF for "13 BB Star" and PASSEQ seismic stations to find the best 2.5D S-wave models down to 60 km depth. National Science Centre Poland provided financial support for this work by NCN grant DEC-2011/02/A/ST10/00284.
2014-01-01
Background Chronic low back pain causes substantial morbidity and cost to society while disproportionately impacting low-income and minority adults. Several randomized controlled trials show yoga is an effective treatment. However, the comparative effectiveness of yoga and physical therapy, a common mainstream treatment for chronic low back pain, is unknown. Methods/Design This is a randomized controlled trial for 320 predominantly low-income minority adults with chronic low back pain, comparing yoga, physical therapy, and education. Inclusion criteria are adults 18–64 years old with non-specific low back pain lasting ≥12 weeks and a self-reported average pain intensity of ≥4 on a 0–10 scale. Recruitment takes place at Boston Medical Center, an urban academic safety-net hospital and seven federally qualified community health centers located in diverse neighborhoods. The 52-week study has an initial 12-week Treatment Phase where participants are randomized in a 2:2:1 ratio into i) a standardized weekly hatha yoga class supplemented by home practice; ii) a standardized evidence-based exercise therapy protocol adapted from the Treatment Based Classification method, individually delivered by a physical therapist and supplemented by home practice; and iii) education delivered through a self-care book. Co-primary outcome measures are 12-week pain intensity measured on an 11-point numerical rating scale and back-specific function measured using the modified Roland Morris Disability Questionnaire. In the subsequent 40-week Maintenance Phase, yoga participants are re-randomized in a 1:1 ratio to either structured maintenance yoga classes or home practice only. Physical therapy participants are similarly re-randomized to either five booster sessions or home practice only. Education participants continue to follow recommendations of educational materials. We will also assess cost effectiveness from the perspectives of the individual, insurers, and society using claims databases, electronic medical records, self-report cost data, and study records. Qualitative data from interviews will add subjective detail to complement quantitative data. Trial registration This trial is registered in ClinicalTrials.gov, with the ID number: NCT01343927. PMID:24568299
NASA Astrophysics Data System (ADS)
Wang, Dongyi; Vinson, Robert; Holmes, Maxwell; Seibel, Gary; Tao, Yang
2018-04-01
The Atlantic blue crab is among the highest-valued seafood found in the American Eastern Seaboard. Currently, the crab processing industry is highly dependent on manual labor. However, there is great potential for vision-guided intelligent machines to automate the meat picking process. Studies show that the back-fin knuckles are robust features containing information about a crab's size, orientation, and the position of the crab's meat compartments. Our studies also make it clear that detecting the knuckles reliably in images is challenging due to the knuckle's small size, anomalous shape, and similarity to joints in the legs and claws. An accurate and reliable computer vision algorithm was proposed to detect the crab's back-fin knuckles in digital images. Convolutional neural networks (CNNs) can localize rough knuckle positions with 97.67% accuracy, transforming a global detection problem into a local detection problem. Compared to the rough localization based on human experience or other machine learning classification methods, the CNN shows the best localization results. In the rough knuckle position, a k-means clustering method is able to further extract the exact knuckle positions based on the back-fin knuckle color features. The exact knuckle position can help us to generate a crab cutline in XY plane using a template matching method. This is a pioneering research project in crab image analysis and offers advanced machine intelligence for automated crab processing.
Jo, Dae-Jean; Kim, Yong-Sang; Kim, Sung-Min; Kim, Ki-Tack; Seo, Eun-Min
2015-10-01
Most thoracolumbar fractures have a good healing outcome with adequate treatment. However, posttraumatic thoracolumbar kyphosis can occur in a proportion of thoracolumbar fractures after inappropriate treatment, osteoporosis, or osteonecrosis of the vertebral body. There are several surgical options to correct posttraumatic thoracolumbar kyphosis, including anterior, posterior, and combined approaches, which are associated with varying degrees of success. The aim of this study was to assess the use of a modified closing wedge osteotomy for the treatment of posttraumatic thoracolumbar kyphosis and to evaluate the radiographic findings and clinical outcomes of patients treated using this technique. Thirteen consecutive patients with symptomatic posttraumatic thoracolumbar kyphosis were treated using a modified closing wedge osteotomy. The mean patient age was 62 years. The kyphosis apex ranged from T-10 to L-2. The sagittal alignment, kyphotic angle, neurological function, visual analog scale for back pain, and Oswestry Disability Index were evaluated before surgery and at follow-up. RESULTS The mean preoperative regional angle was 27.4°, and the mean correction angle was 29.6°. Sagittal alignment improved with a mean correction rate of 58.3%. The mean surgical time was 275 minutes, and the mean intraoperative blood loss was 1585 ml. The intraoperative complications included 2 dural tears, 1 nerve root injury, and 1 superficial wound infection. The mean visual analog scale score for back pain improved from 6. 6 to 2, and the Oswestry Disability Index score decreased from 55.4 to 22.6 at the last follow-up. All patients achieved bony anterior fusion based on the presence of trabecular bone bridging at the osteotomy site. The modified posterior closing wedge osteotomy technique achieves satisfactory kyphosis correction with direct visualization of the circumferentially decompressed spinal cord, as well as good fusion with less blood loss and fewer complications. It is an alternative method for treating patients with posttraumatic thoracolumbar kyphosis.
1999-06-19
In the Space Station Processing Facility, STS-99 crew members inspect the Shuttle Radar Topography Mission (SRTM), the payload for their mission. At left is Commander Kevin R. Kregel talking to Mission Specialist Janice Voss (Ph.D.); and Mission Specialists Gerhard Thiele of Germany and Mamoru Mohri of Japan farther back. In the foreground (back to camera) is Mission Specialist Janet Lynn Kavandi (Ph.D.). The final crew member (not shown) is Pilot Dominic L. Pudwill Gorie. Thiele represents the European Space Agency and Mohri represents the National Space Agency of Japan. An international project spearheaded by the National Imagery and Mapping Agency and NASA, with participation of the German Aerospace Center DLR, the SRTM consists of a specially modified radar system that will gather data for the most accurate and complete topographic map of the Earth's surface that has ever been assembled. SRTM will make use of radar interferometry, wherein two radar images are taken from slightly different locations. Differences between these images allow for the calculation of surface elevation, or change. The SRTM hardware will consist of one radar antenna in the shuttle payload bay and a second radar antenna attached to the end of a mast extended 60 meters (195 feet) out from the shuttle. STS-99 is scheduled to launch Sept. 16 at 8:47 a.m. from Launch Pad 39A
[The design of all solid-state tunable pulsed Ti:sapphire laser system].
Chen, Zhe; Ku, Geng; Wan, Junchao; Wang, Wei; Zhou, Chuanqing
2013-05-01
This paper presented a design of broadly all solid-state tunable pulsed Ti:sapphire laser with high power and stable performance. The laser was pumped by custom-made Nd:YAG laser which had water cooling system and amplified by two stage amplifier. The method accomplished tunable output of all solid-state tunable pulsed Ti:sapphire laser by modifying the reflection angle of the back mirror. We investigated the relationship between the power of the pumping laser and the all solid-state tunable pulsed Ti: sapphire laser by changing the power of the pumping source.
NASA Astrophysics Data System (ADS)
Piatkowski, Marian; Müthing, Steffen; Bastian, Peter
2018-03-01
In this paper we consider discontinuous Galerkin (DG) methods for the incompressible Navier-Stokes equations in the framework of projection methods. In particular we employ symmetric interior penalty DG methods within the second-order rotational incremental pressure correction scheme. The major focus of the paper is threefold: i) We propose a modified upwind scheme based on the Vijayasundaram numerical flux that has favourable properties in the context of DG. ii) We present a novel postprocessing technique in the Helmholtz projection step based on H (div) reconstruction of the pressure correction that is computed locally, is a projection in the discrete setting and ensures that the projected velocity satisfies the discrete continuity equation exactly. As a consequence it also provides local mass conservation of the projected velocity. iii) Numerical results demonstrate the properties of the scheme for different polynomial degrees applied to two-dimensional problems with known solution as well as large-scale three-dimensional problems. In particular we address second-order convergence in time of the splitting scheme as well as its long-time stability.
Research to Real Life, 2006: Innovations in Deaf-Blindness
ERIC Educational Resources Information Center
Leslie, Gail, Ed.
2006-01-01
This publication presents several projects that support children who are deaf-blind. These projects are: (1) Learning To Learn; (2) Project SALUTE; (3) Project SPARKLE; (4) Bringing It All Back Home; (5) Project PRIIDE; and (6) Including Students With Deafblindness In Large Scale Assessment Systems. Each project lists components, key practices,…
The Impact of Biofilms on the Process of Back Diffusion From a Contaminated Rock Matrix
NASA Astrophysics Data System (ADS)
Yungwirth, G. A.; Novakowski, K. S.; Ross, N.
2005-12-01
Groundwater remediation in fractured rock settings is complicated by the diffusion of contaminants into the rock matrix and the subsequent back diffusion into the fractures. The process of back diffusion, in particular, leads to extended periods of low-level contamination in the fracture network that persists long after the source area is hydraulically or otherwise removed. In such a case, we hypothesize that back diffusion could be limited by growing a biofilm which coats the rock fracture surface and potentially invades the rock micropores. This would effectively sequester the contamination potentially in perpetuity. To explore the viability of this concept, diffusion experiments were conducted in which the effect of biofilm growth on diffusion through thin (0.8 to 1.2 cm) slices of dolostone core obtained from the Lockport Formation, Southern Ontario, was investigated. The experiments were conducted using a double-cell method, in which the core slices were encapsulated inside Teflon coated hydraulic hose, fitted with ultra high molecular weight polyethylene endcaps having stainless steel sample ports. Diffusion was established across the core slice by spiking one reservoir with a conservative tracer and monitoring the tracer arrival in the reservoir located on the other side of the coupon. The experiments were conducted both in the presence and absence of a biofilm. Biofilm was grown on the rock coupons in a separate bath before the coupons were transferred to the apparatus for the diffusion experiments. Microbial populations indigenous to the groundwater used in the bath were stimulated to form the biofilm with the addition of a beef extract and peptone nutrient broth in 1g/L concentration. The extent of biofilm growth was monitored using a modified Dubois et al (1956) colorimetric method for sugar determination. Results were simulated using an analytical model that was developed for the geometry of the diffusion experiments. Governing equations for the model are based on a cylindrical coordinate system where one equation was developed for the rock and another for the biofilm. The solution was found using the Laplace Transform method. Preliminary results show substantial biofilm growth, confirming that the method of biofilm stimulation is viable. Preliminary analysis of data from the diffusion experiments shows the impact of biofilm presence on back diffusion to be profound.
Stevens, S; Dvorak, P; Spevacek, V; Pilarova, K; Bray-Parry, M; Gesner, J; Richmond, A
2018-01-01
To provide a 3D dosimetric evaluation of a commercial portal dosimetry system using 2D/3D detectors under ideal conditions using VMAT. A 2D ion chamber array, radiochromic film and gel dosimeter were utilised to provide a dosimetric evaluation of transit phantom and pre-treatment 'fluence' EPID back-projected dose distributions for a standard VMAT plan. In-house 2D and 3D gamma methods compared pass statistics relative to each dosimeter and TPS dose distributions. Fluence mode and transit EPID dose distributions back-projected onto phantom geometry produced 2D gamma pass rates in excess of 97% relative to other tested detectors and exported TPS dose planes when a 3%, 3 mm global gamma criterion was applied. Use of a gel dosimeter within a glass vial allowed comparison of measured 3D dose distributions versus EPID 3D dose and TPS calculated distributions. 3D gamma comparisons between modalities at 3%, 3 mm gave pass rates in excess of 92%. Use of fluence mode was indicative of transit results under ideal conditions with slightly reduced dose definition. 3D EPID back projected dose distributions were validated against detectors in both 2D and 3D. Cross validation of transit dose delivered to a patient is limited due to reasons of practicality and the tests presented are recommended as a guideline for 3D EPID dosimetry commissioning; allowing direct comparison between detector, TPS, fluence and transit modes. The results indicate achievable gamma scores for a complex VMAT plan in a homogenous phantom geometry and contributes to growing experience of 3D EPID dosimetry. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
GPU Accelerated Ultrasonic Tomography Using Propagation and Back Propagation Method
2015-09-28
the medical imaging field using GPUs has been done for many years. In [1], Copeland et al. used 2D images , obtained by X - ray projections, to...Index Terms— Medical Imaging , Ultrasonic Tomography, GPU, CUDA, Parallel Computing I. INTRODUCTION GRAPHIC Processing Units (GPUs) are computation... Imaging Algorithm The process of reconstructing images from ultrasonic infor- mation starts with the following acoustical wave equation: ∂2 ∂t2 u ( x
Keeping the Dogs in the Fight: What Combatant Commanders Need to Know about MWDs
2013-05-20
Manhattan Project that Bombed,” Public Integrity, Last modified August 2011, http://www.publicintegrity.org/2011/03/27/3799/jieddo- manhattan - project -bombed...Carey, Peter. “JIEDDO: The Manhattan Project that Bombed.” Public Integrity. Last modified August 2011. http://www.publicintegrity.org/2011/03/27...3799/jieddo- manhattan - project -bombed. Community Marines. “MCO 5580.2B.” Last modified August 2008. http://community.marines.mil/news
2007-07-01
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Atlantis on top lifts off from Edwards Air Force Base to begin its ferry flight back to the Kennedy Space Center in Florida. The cross-country journey will take approximately two days, with stops at several intermediate points for refueling.
2004-06-22
Leah Robson and Bridgette Puljiz of Tehachapi (seated) and Zachary Johnson of Palmdale (back to camera) look over the maze of dials and switches in the flight deck of NASA's modified Boeing 747 space shuttle carrier aircraft during Take Your Children to Work Day June 22 at NASA Dryden Flight Research Center.
A modified constitutive model for creep of Sn-3.5Ag-0.7Cu solder joints
NASA Astrophysics Data System (ADS)
Han, Y. D.; Jing, H. Y.; Nai, S. M. L.; Tan, C. M.; Wei, J.; Xu, L. Y.; Zhang, S. R.
2009-06-01
In this study, the constitutive behaviour for creep performance of 95.8Sn-3.5Ag-0.7Cu lead-free solder joints was investigated. It was observed that the stress exponent (n) can be well defined into two stress regimes: low stress and high stress. A new, improved constitutive model, which considered back stress, was proposed to describe the creep behaviour of SnAgCu solder joints. In this model, the back stress, which is a function of the applied shear stress in the low stress regime (LSR) and a function of the particle size, volume fraction and coarsening of IMC particles in the high stress regime (HSR), was introduced to construct the relationship between the creep strain rate and the shear stress. The creep mechanism in these two stress regimes was studied in detail. In the LSR, dislocations passed through the matrix by climbing over the intermetallic particles, while in the HSR, the dislocations were glide-controlled. According to the different creep mechanisms in both the stress regimes, the back stress was calculated, respectively, and then incorporated into the Arrhenius power-law creep model. It was demonstrated that the predicted strain rate-shear stress behaviour employing the modified creep constitutive model which considered back stress, was in good agreement with the experimental results.
T-34C back seat instrument panel
1997-05-15
The back seat instrument panel on the NASA T-34C chase plane. In its role as a military trainer, the instructor pilot would ride in the back seat, while the student would be in the front seat. As a chase plane, the back seat would be occupied by a photographer. The aircraft was previously used at the Lewis Research Center in propulsion experiments involving turboprop engines, and was used as a chase aircraft at Dryden for smaller and slower research projects. Chase aircraft accompany research flights for photography and video purposes, and also as support for safety and research. At Dryden, the T-34 is used mainly for smaller remotely piloted vehicles which fly slower than NASA's F-18's, used for larger scale projects. This aircraft was returned to the U.S. Navy in May of 2002. The T-34C, built by Beech, carries a crew of 2 and is nicknamed the Mentor.
Stop Using the Modified Work APGAR to Measure Job Satisfaction
Mielenz, Thelma J.; DeVellis, Robert F.; Battie, Michele C.; Carey, Timothy S.
2011-01-01
Background. The psychometric properties of the Modified Work APGAR (MWA) scale are not established, yet researchers use this scale as an overall measure of job satisfaction. Objective. Perform psychometric analyses on the MWA scale using data from two populations. Methods. A landmark occupational cohort and a clinical cohort are populations with low back pain studied. The first five items of the MWA scale measure social support from coworkers, one item measures dissatisfaction with job tasks, and the sixth item measures lack of social support from a supervisor. Exploratory principal components analyses were conducted in both cohorts. Results. In both cohorts, the first five items of the MWA scale loaded consistently onto one factor, social support from coworkers subscale. Conclusions. Unless researchers are interested in measuring social support from coworkers only, future studies should use other reliable and valid instruments to measure a broad range of psychosocial work characteristics. PMID:22191021
Space Shuttle Damper System for Ground Wind Load Tests
NASA Technical Reports Server (NTRS)
Robinson, G. D.; Holt, J. R.; Chang, C. S.
1973-01-01
An active damper system which was originally developed for a 5.5% Saturn IB/Skylab Ground Winds Model was modified and used for similar purposes in a Space Shuttle model. A second damper system which was originally used in a 3% Saturn V/Dry Workshop model was also modified and made compatible with the Space Shuttle model to serve as a back-up system. Included in this final report are descriptions of the modified damper systems and the associated control and instrumentation.
Understanding interaction of curcumin and metal ions on electrode surfaces using EDXRF
NASA Astrophysics Data System (ADS)
Joseph, Daisy; Kumar, K. Krishna; Narayanan, S. Sriman
2018-04-01
A chemically modified electrode was developed for determination of metal ions (Cd, Pb, Zn, Co, Hg). The modifier used for the study was Curcumin. Curcumin acts as a complexing agent at the surface of the electrode for preconcentration of metal ions from electrolyte to electrode surface and stripped back to electrolyte during analysis. EDXRF was used to analyze these electrodes and it was concluded that the PCR modified electrode favored effective chelation for lead and mercury.
Contribution of European research to risk analysis.
Boenke, A
2001-12-01
The European Commission's, Quality of Life Research Programme, Key Action 1-Health, Food & Nutrition is mission-oriented and aims, amongst other things, at providing a healthy, safe and high-quality food supply leading to reinforced consumer confidence in the safety, of European food. Its objectives also include the enhancing of the competitiveness of the European food supply. Key Action 1 is currently supporting a number of different types of European collaborative projects in the area of risk analysis. The objectives of these projects range from the development and validation of prevention strategies including the reduction of consumers risks; development and validation of new modelling approaches, harmonization of risk assessment principles methodologies and terminology; standardization of methods and systems used for the safety evaluation of transgenic food; providing of tools for the evaluation of human viral contamination of shellfish and quality control; new methodologies for assessing the potential of unintended effects of genetically modified (genetically modified) foods; development of a risk assessment model for Cryptosporidium parvum related to the food and water industries, to the development of a communication platform for genetically modified organism, producers, retailers, regulatory authorities and consumer groups to improve safety assessment procedures, risk management strategies and risk communication; development and validation of new methods for safety testing of transgenic food; evaluation of the safety and efficacy of iron supplementation in pregnant women, evaluation of the potential cancer-preventing activity of pro- and pre-biotic ('synbiotic') combinations in human volunteers. An overview of these projects is presented here.
Advanced Guidance and Control Project for Reusable Launch Vehicles
NASA Technical Reports Server (NTRS)
Hanson, John M.
2000-01-01
The goals of this project are to significantly reduce the time and cost associated with guidance and control design for reusable launch vehicles, and to increase their safety and reliability. Success will lead to reduced cycle times during vehicle design and to reduced costs associated with flying to new orbits, with new payloads, and with modified vehicles. Success will also lead to more robustness to unforeseen circumstances in flight thereby enhancing safety and reducing risk. There are many guidance and control methods available that hold some promise for improvement in the desired areas. Investigators are developing a representative set of independent guidance and control methods for this project. These methods are being incorporated into a high-fidelity off is being conducted across a broad range of flight requirements. The guidance and control methods that perform the best will have demonstrated the desired qualities.
2010-01-01
Background Patients with signs of nerve root irritation represent a sub-group of those with low back pain who are at increased risk of persistent symptoms and progression to costly and invasive management strategies including surgery. A period of non-surgical management is recommended for most patients, but there is little evidence to guide non-surgical decision-making. We conducted a preliminary study examining the effectiveness of a treatment protocol of mechanical traction with extension-oriented activities for patients with low back pain and signs of nerve root irritation. The results suggested this approach may be effective, particularly in a more specific sub-group of patients. The aim of this study will be to examine the effectiveness of treatment that includes traction for patients with low back pain and signs of nerve root irritation, and within the pre-defined sub-group. Methods/Design The study will recruit 120 patients with low back pain and signs of nerve root irritation. Patients will be randomized to receive an extension-oriented treatment approach, with or without the addition of mechanical traction. Randomization will be stratified based on the presence of the pre-defined sub-grouping criteria. All patients will receive 12 physical therapy treatment sessions over 6 weeks. Follow-up assessments will occur after 6 weeks, 6 months, and 1 year. The primary outcome will be disability measured with a modified Oswestry questionnaire. Secondary outcomes will include self-reports of low back and leg pain intensity, quality of life, global rating of improvement, additional healthcare utilization, and work absence. Statistical analysis will be based on intention to treat principles and will use linear mixed model analysis to compare treatment groups, and examine the interaction between treatment and sub-grouping status. Discussion This trial will provide a methodologically rigorous evaluation of the effectiveness of using traction for patients with low back pain and signs of nerve root irritation, and will examine the validity of a pre-defined sub-grouping hypothesis. The results will provide evidence to inform non-surgical decision-making for these patients. Trial Registration This trial has been registered with http://ClinicalTrials.gov: NCT00942227 PMID:20433733
An object-oriented simulator for 3D digital breast tomosynthesis imaging system.
Seyyedi, Saeed; Cengiz, Kubra; Kamasak, Mustafa; Yildirim, Isa
2013-01-01
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values.
An Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System
Cengiz, Kubra
2013-01-01
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values. PMID:24371468
NASA Astrophysics Data System (ADS)
Oyler, J.; Anderson, R.; Running, S. W.
2010-12-01
In topographically complex landscapes, there is often a mismatch in scale between global climate model projections and more local climate-forcing factors and related ecological/hydrological processes. To overcome this limitation, the objective of this study was to downscale climate projections to the rugged Crown of the Continent Ecosystem (CCE) within the U.S. Northern Rockies and assess future impacts on water balances, vegetation dynamics, and carbon fluxes. A 40-year (1970-2009) spatial historical climate dataset (800m resolution, daily timestep) was generated for the CCE and modified for terrain influences. Regional climate projections were downscaled by applying them to the fine-scale historical dataset using a modified delta downscaling method and stochastic weather generator. The downscaled projections were used to drive the Biome-BGC ecosystem model. Overall CCE impacts included decreases in April 1 snow water equivalent, less days with snow on the ground, increased vegetation water stress, and increased growing degree days. The relaxing of temperature constraints increased annual net primary productivity (NPP) throughout most of the CCE landscape. However, an increase in water stress seems to have limited the growth in NPP and, in some areas, NPP actually decreased. Thus, CCE vegetation productivity trends under increasing temperatures will likely be determined by local changes in hydrologic function. Given the greater uncertainty in precipitation projections, future work should concentrate on determining thresholds in water constraints that greatly modify the magnitude and direction of carbon accumulation within the CCE under a warming climate.
A modified Dodge algorithm for the parabolized Navier-Stokes equation and compressible duct flows
NASA Technical Reports Server (NTRS)
Cooke, C. H.
1981-01-01
A revised version of Dodge's split-velocity method for numerical calculation of compressible duct flow was developed. The revision incorporates balancing of mass flow rates on each marching step in order to maintain front-to-back continuity during the calculation. The (checkerboard) zebra algorithm is applied to solution of the three dimensional continuity equation in conservative form. A second-order A-stable linear multistep method is employed in effecting a marching solution of the parabolized momentum equations. A checkerboard iteration is used to solve the resulting implicit nonlinear systems of finite-difference equations which govern stepwise transition. Qualitive agreement with analytical predictions and experimental results was obtained for some flows with well-known solutions.
Bellon, L; Maloney, L; Zinnen, S P; Sandberg, J A; Johnson, K E
2000-08-01
Versatile bioanalytical assays to detect chemically stabilized hammerhead ribozyme and putative ribozyme metabolites from plasma are described. The extraction protocols presented are based on serial solid-phase extractions performed on a 96-well plate format and are compatible with either IEX-HPLC or CGE back-end analysis. A validation of both assays confirmed that both the HPLC and the CGE methods possess the required linearity, accuracy, and precision to accurately measure concentrations of hammerhead ribozyme extracted from plasma. These methods should be of general use to detect and quantitate ribozymes from other biological fluids such as serum and urine. Copyright 2000 Academic Press.
Miéville, Frédéric A; Gudinchet, François; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, François O; Verdun, Francis R
2011-09-01
Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas
2014-06-15
Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo undermore » weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.« less
26 CFR 1.460-6 - Look-back method.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) for the redetermination year, as adjusted for past applications of the look-back method and taking... the year in question with respect to other contracts. Notwithstanding the look-back method, the...) INCOME TAXES Taxable Year for Which Items of Gross Income Included § 1.460-6 Look-back method. (a) In...
Efficacy of core muscle strengthening exercise in chronic low back pain patients.
Kumar, Tarun; Kumar, Suraj; Nezamuddin, Md; Sharma, V P
2015-01-01
Low back pain is a common health problem in human being and about 5 to 15% will develop chronic low back pain (CLBP). The clinical findings of CLBP suggest that lumbar mobility is decreased and recruitment order of core muscles is altered. In literature, there is no data about the effect of core muscles strengthening in the chronicity (short duration, long duration) of CLBP. This study evaluated the effect of core muscle strengthening intervention on chronicity of chronic low back pain. Thirty patients were recruited from the outpatient department of the National Institute for the Orthopaedically Handicapped. These 30 patients divided into two groups: A and B on the basis of duration of low back pain. Group-A patients complain about pain duration for more than twelve months and Group B complains about pain duration from three to twelve months. Both the groups were received same intervention for six weeks. Assessment was done pre intervention and post intervention after six weeks for both the groups. %For both the groups the assessment was done after six weeks for pre and post intervention. The result described both the groups showed improvement in all the outcome measures including pain as well as in function using Numerical pain rating scale, Oswestry Disability Index, Sorensen test, Gluteus Maximus Strength, Activation of transversus abdominis and Modified-Modified Schober's Test. The improvement was statistically non-significant with inter groups and significant within group. This study concludes that core muscle strengthening exercise along with lumbar flexibility and gluteus maximus strengthening is an effective rehabilitation technique for all chronic low back pain patients irrespective of duration (less than one year and more than one year) of their pain.
Descarreaux, Martin; Blouin, Jean-Sébastien; Drolet, Marc; Papadimitriou, Stanislas; Teasdale, Normand
2004-10-01
To document the potential role of maintenance chiropractic spinal manipulation to reduce overall pain and disability levels associated with chronic low-back conditions after an initial phase of intensive chiropractic treatments. Thirty patients with chronic nonspecific low-back pain were separated into 2 groups. The first group received 12 treatments in an intensive 1-month period but received no treatment in a subsequent 9-month period. For this group, a 4-week period preceding the initial phase of treatment was used as a control period to examine the sole effect of time on pain and disability levels. The second group received 12 treatments in an intensive 1-month period and also received maintenance spinal manipulation every 3 weeks for a 9-month follow-up period. Pain and disability levels were evaluated with a visual analog scale and a modified Oswestry questionnaire, respectively. The 1-month control period did not modify the pain and disability levels. For both groups, the pain and disability levels decreased after the intensive phase of treatments. Both groups maintained their pain scores at levels similar to the postintensive treatments throughout the follow-up period. For the disability scores, however, only the group that was given spinal manipulations during the follow-up period maintained their postintensive treatment scores. The disability scores of the other group went back to their pretreatment levels. Intensive spinal manipulation is effective for the treatment of chronic low back pain. This experiment suggests that maintenance spinal manipulations after intensive manipulative care may be beneficial to patients to maintain subjective postintensive treatment disability levels. Future studies, however, are needed to confirm the finding in a larger group of patients with chronic low-back pain.
Shi, Hongli; Yang, Zhi; Luo, Shuqian
2017-01-01
The beam hardening artifact is one of most important modalities of metal artifact for polychromatic X-ray computed tomography (CT), which can impair the image quality seriously. An iterative approach is proposed to reduce beam hardening artifact caused by metallic components in polychromatic X-ray CT. According to Lambert-Beer law, the (detected) projections can be expressed as monotonic nonlinear functions of element geometry projections, which are the theoretical projections produced only by the pixel intensities (image grayscale) of certain element (component). With help of a prior knowledge on spectrum distribution of X-ray beam source and energy-dependent attenuation coefficients, the functions have explicit expressions. Newton-Raphson algorithm is employed to solve the functions. The solutions are named as the synthetical geometry projections, which are the nearly linear weighted sum of element geometry projections with respect to mean of each attenuation coefficient. In this process, the attenuation coefficients are modified to make Newton-Raphson iterative functions satisfy the convergence conditions of fixed pointed iteration(FPI) so that the solutions will approach the true synthetical geometry projections stably. The underlying images are obtained using the projections by general reconstruction algorithms such as the filtered back projection (FBP). The image gray values are adjusted according to the attenuation coefficient means to obtain proper CT numbers. Several examples demonstrate the proposed approach is efficient in reducing beam hardening artifacts and has satisfactory performance in the term of some general criteria. In a simulation example, the normalized root mean square difference (NRMSD) can be reduced 17.52% compared to a newest algorithm. Since the element geometry projections are free from the effect of beam hardening, the nearly linear weighted sum of them, the synthetical geometry projections, are almost free from the effect of beam hardening. By working out the synthetical geometry projections, the proposed approach becomes quite efficient in reducing beam hardening artifacts.
Mattioli Della Rocca, Francescopaolo
2018-01-01
This paper examines methods to best exploit the High Dynamic Range (HDR) of the single photon avalanche diode (SPAD) in a high fill-factor HDR photon counting pixel that is scalable to megapixel arrays. The proposed method combines multi-exposure HDR with temporal oversampling in-pixel. We present a silicon demonstration IC with 96 × 40 array of 8.25 µm pitch 66% fill-factor SPAD-based pixels achieving >100 dB dynamic range with 3 back-to-back exposures (short, mid, long). Each pixel sums 15 bit-planes or binary field images internally to constitute one frame providing 3.75× data compression, hence the 1k frames per second (FPS) output off-chip represents 45,000 individual field images per second on chip. Two future projections of this work are described: scaling SPAD-based image sensors to HDR 1 MPixel formats and shrinking the pixel pitch to 1–3 µm. PMID:29641479
Solution of nonlinear time-dependent PDEs through componentwise approximation of matrix functions
NASA Astrophysics Data System (ADS)
Cibotarica, Alexandru; Lambers, James V.; Palchak, Elisabeth M.
2016-09-01
Exponential propagation iterative (EPI) methods provide an efficient approach to the solution of large stiff systems of ODEs, compared to standard integrators. However, the bulk of the computational effort in these methods is due to products of matrix functions and vectors, which can become very costly at high resolution due to an increase in the number of Krylov projection steps needed to maintain accuracy. In this paper, it is proposed to modify EPI methods by using Krylov subspace spectral (KSS) methods, instead of standard Krylov projection methods, to compute products of matrix functions and vectors. Numerical experiments demonstrate that this modification causes the number of Krylov projection steps to become bounded independently of the grid size, thus dramatically improving efficiency and scalability. As a result, for each test problem featured, as the total number of grid points increases, the growth in computation time is just below linear, while other methods achieved this only on selected test problems or not at all.
Fermilab History and Archives Project | Norman F. Ramsey
Fermilab History and Archives Project Fermilab History and Archives Project Fermilab History and Archives Project Home About the Archives History and Archives Online Request Contact Us History & ; Archives Project Fermilab History and Archives Project Norman F. Ramsey Back to History and Archives
General practitioners’ views on radiology reports of plain radiography for back pain
Espeland, Ansgar; Baerheim, Anders
2007-01-01
Objective To identify and describe general practitioners’ (GPs’) views on radiology reports, using plain radiography for back pain as the case. Design Qualitative study with three focus-group interviews analysed using Giorgi's method as modified by Malterud. Setting Southern Norway. Subjects Five female and eight male GPs aged 32–57 years who had practised for 3–15 years and were from 11 different practices. Main outcome measures Descriptions of GPs’ views. Results GPs wanted radiology reports to indicate more clearly the meaning of radiological terminology, the likelihood of disease, the clinical relevance of the findings, and/or the need for further investigations. GPs stated that good referral information leads to better reports. Conclusion These results can help to improve communication between radiologists and GPs. The issues identified in this study could be further investigated in studies that can quantify GPs’ satisfaction with radiology reports in relation to characteristics of the GP, the radiologist, and the referral information. PMID:17354154
Balabin, Roman M; Smirnov, Sergey V
2011-04-29
During the past several years, near-infrared (near-IR/NIR) spectroscopy has increasingly been adopted as an analytical tool in various fields from petroleum to biomedical sectors. The NIR spectrum (above 4000 cm(-1)) of a sample is typically measured by modern instruments at a few hundred of wavelengths. Recently, considerable effort has been directed towards developing procedures to identify variables (wavelengths) that contribute useful information. Variable selection (VS) or feature selection, also called frequency selection or wavelength selection, is a critical step in data analysis for vibrational spectroscopy (infrared, Raman, or NIRS). In this paper, we compare the performance of 16 different feature selection methods for the prediction of properties of biodiesel fuel, including density, viscosity, methanol content, and water concentration. The feature selection algorithms tested include stepwise multiple linear regression (MLR-step), interval partial least squares regression (iPLS), backward iPLS (BiPLS), forward iPLS (FiPLS), moving window partial least squares regression (MWPLS), (modified) changeable size moving window partial least squares (CSMWPLS/MCSMWPLSR), searching combination moving window partial least squares (SCMWPLS), successive projections algorithm (SPA), uninformative variable elimination (UVE, including UVE-SPA), simulated annealing (SA), back-propagation artificial neural networks (BP-ANN), Kohonen artificial neural network (K-ANN), and genetic algorithms (GAs, including GA-iPLS). Two linear techniques for calibration model building, namely multiple linear regression (MLR) and partial least squares regression/projection to latent structures (PLS/PLSR), are used for the evaluation of biofuel properties. A comparison with a non-linear calibration model, artificial neural networks (ANN-MLP), is also provided. Discussion of gasoline, ethanol-gasoline (bioethanol), and diesel fuel data is presented. The results of other spectroscopic techniques application, such as Raman, ultraviolet-visible (UV-vis), or nuclear magnetic resonance (NMR) spectroscopies, can be greatly improved by an appropriate feature selection choice. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Ina; French, Roger H.
Our project objective in the first and only Budget Period was to demonstrate the potential of nm-scale organofunctional silane coatings as a method of extending the lifetime of PV materials and devices. Specifically, the target was to double the lifetime performance of a laminated Cu(In,Ga)Se2 (CIGS) cell under real-world and accelerated aging exposure conditions. Key findings are that modification of aluminum-doped zinc oxide (AZO) films (materials used as transparent conductive oxide (TCO) top contacts) resulted in decreased degradation of optical and electrical properties under damp heat (DH) exposure compared to un-modified AZO. The most significant finding is that modification ofmore » the AZO top contact of full CIGS devices resulted in significantly improved properties under DH exposure compared to un-modified devices, by a factor of 4 after 1000 h. Results of this one-year project have demonstrated that surface functionalization is a viable pathway for extending the lifetime of state-of-the-art CIGS devices.« less
Irreducible projective representations and their physical applications
NASA Astrophysics Data System (ADS)
Yang, Jian; Liu, Zheng-Xin
2018-01-01
An eigenfunction method is applied to reduce the regular projective representations (Reps) of finite groups to obtain their irreducible projective Reps. Anti-unitary groups are treated specially, where the decoupled factor systems and modified Schur’s lemma are introduced. We discuss the applications of irreducible Reps in many-body physics. It is shown that in symmetry protected topological phases, geometric defects or symmetry defects may carry projective Rep of the symmetry group; while in symmetry enriched topological phases, intrinsic excitations (such as spinons or visons) may carry projective Rep of the symmetry group. We also discuss the applications of projective Reps in problems related to spectrum degeneracy, such as in search of models without sign problem in quantum Monte Carlo simulations.
Terrestrial Environmental Variables Derived From EOS Platform Sensors
NASA Technical Reports Server (NTRS)
Stadler, Stephen J.; Czajkowski, Kevin P.; Goward, Samuel N.; Xue, Yongkang
2001-01-01
The three main objectives of the overall project were: 1. Adaptation of environmental constraint methods to take advantage of EOS sensors, specifically, MODIS, ASTER, and Landsat-7, in addition to the PM AVHRR observations 2. Refinement of environmental constraint methods based on fundamental scientific knowledge. 3. Assessment of spatial scaling patterns in environmental constraint measurements to evaluate the potential biases and errors that occur when estimating regional and global-scale NPP patterns with moderate to coarse satellite observations. These goals were modified because, on one hand, MODIS data did not become available until after the first year of the project and because of project staffing issues at the University of Maryland., The OSU portion of the project contained a modest amount of funding and responsibility compared to the University of Maryland and the University of Toledo.
Effect of accuracy of wind power prediction on power system operator
NASA Technical Reports Server (NTRS)
Schlueter, R. A.; Sigari, G.; Costi, T.
1985-01-01
This research project proposed a modified unit commitment that schedules connection and disconnection of generating units in response to load. A modified generation control is also proposed that controls steam units under automatic generation control, fast responding diesels, gas turbines and hydro units under a feedforward control, and wind turbine array output under a closed loop array control. This modified generation control and unit commitment require prediction of trend wind power variation one hour ahead and the prediction of error in this trend wind power prediction one half hour ahead. An improved meter for predicting trend wind speed variation is developed. Methods for accurately simulating the wind array power from a limited number of wind speed prediction records was developed. Finally, two methods for predicting the error in the trend wind power prediction were developed. This research provides a foundation for testing and evaluating the modified unit commitment and generation control that was developed to maintain operating reliability at a greatly reduced overall production cost for utilities with wind generation capacity.
NASA Astrophysics Data System (ADS)
Tan, Zhukui; Xie, Baiming; Zhao, Yuanliang; Dou, Jinyue; Yan, Tong; Liu, Bin; Zeng, Ming
2018-06-01
This paper presents a new integrated planning framework for effective accommodating electric vehicles in smart distribution systems (SDS). The proposed method incorporates various investment options available for the utility collectively, including distributed generation (DG), capacitors and network reinforcement. Using a back-propagation algorithm combined with cost-benefit analysis, the optimal network upgrade plan, allocation and sizing of the selected components are determined, with the purpose of minimizing the total system capital and operating costs of DG and EV accommodation. Furthermore, a new iterative reliability test method is proposed. It can check the optimization results by subsequently simulating the reliability level of the planning scheme, and modify the generation reserve margin to guarantee acceptable adequacy levels for each year of the planning horizon. Numerical results based on a 32-bus distribution system verify the effectiveness of the proposed method.
NASA Astrophysics Data System (ADS)
Fujii, M.
2017-07-01
Two variations of a depth-selective back-projection filter for functional near-infrared spectroscopy (fNIRS) systems are introduced. The filter comprises a depth-selective algorithm that uses inverse problems applied to an optically diffusive multilayer medium. In this study, simultaneous signal reconstruction of both superficial and deep tissue from fNIRS experiments of the human forehead using a prototype of a CW-NIRS system is demonstrated.
Jacobsen, S.; Birkelund, Y.
2010-01-01
Microwave breast cancer detection is based on the dielectric contrast between healthy and malignant tissue. This radar-based imaging method involves illumination of the breast with an ultra-wideband pulse. Detection of tumors within the breast is achieved by some selected focusing technique. Image formation algorithms are tailored to enhance tumor responses and reduce early-time and late-time clutter associated with skin reflections and heterogeneity of breast tissue. In this contribution, we evaluate the performance of the so-called cross-correlated back projection imaging scheme by using a scanning system in phantom experiments. Supplementary numerical modeling based on commercial software is also presented. The phantom is synthetically scanned with a broadband elliptical antenna in a mono-static configuration. The respective signals are pre-processed by a data-adaptive RLS algorithm in order to remove artifacts caused by antenna reverberations and signal clutter. Successful detection of a 7 mm diameter cylindrical tumor immersed in a low permittivity medium was achieved in all cases. Selecting the widely used delay-and-sum (DAS) beamforming algorithm as a benchmark, we show that correlation based imaging methods improve the signal-to-clutter ratio by at least 10 dB and improves spatial resolution through a reduction of the imaged peak full-width half maximum (FWHM) of about 40–50%. PMID:21331362
Jacobsen, S; Birkelund, Y
2010-01-01
Microwave breast cancer detection is based on the dielectric contrast between healthy and malignant tissue. This radar-based imaging method involves illumination of the breast with an ultra-wideband pulse. Detection of tumors within the breast is achieved by some selected focusing technique. Image formation algorithms are tailored to enhance tumor responses and reduce early-time and late-time clutter associated with skin reflections and heterogeneity of breast tissue. In this contribution, we evaluate the performance of the so-called cross-correlated back projection imaging scheme by using a scanning system in phantom experiments. Supplementary numerical modeling based on commercial software is also presented. The phantom is synthetically scanned with a broadband elliptical antenna in a mono-static configuration. The respective signals are pre-processed by a data-adaptive RLS algorithm in order to remove artifacts caused by antenna reverberations and signal clutter. Successful detection of a 7 mm diameter cylindrical tumor immersed in a low permittivity medium was achieved in all cases. Selecting the widely used delay-and-sum (DAS) beamforming algorithm as a benchmark, we show that correlation based imaging methods improve the signal-to-clutter ratio by at least 10 dB and improves spatial resolution through a reduction of the imaged peak full-width half maximum (FWHM) of about 40-50%.
Experiences Using Formal Methods for Requirements Modeling
NASA Technical Reports Server (NTRS)
Easterbrook, Steve; Lutz, Robyn; Covington, Rick; Kelly, John; Ampo, Yoko; Hamilton, David
1996-01-01
This paper describes three cases studies in the lightweight application of formal methods to requirements modeling for spacecraft fault protection systems. The case studies differ from previously reported applications of formal methods in that formal methods were applied very early in the requirements engineering process, to validate the evolving requirements. The results were fed back into the projects, to improve the informal specifications. For each case study, we describe what methods were applied, how they were applied, how much effort was involved, and what the findings were. In all three cases, the formal modeling provided a cost effective enhancement of the existing verification and validation processes. We conclude that the benefits gained from early modeling of unstable requirements more than outweigh the effort needed to maintain multiple representations.
Sleep Better at Night...Back Up Your Data.
ERIC Educational Resources Information Center
Smith, Russell
1996-01-01
Discusses the need to back up computer files, and describes the technological evolution of back-up methods. Reviews tape drive and external hard drive back-up products offered by computer companies and presents back-up strategies to use with all back-up methods. A sidebar lists information on the reviewed products. (JMV)
Telephone interview strategy can be used for screening inflammatory back pain in the community.
Solmaz, Dilek; Gunduz, Ozgul; Akar, Servet; Can, Gercek; Birlik, Merih; Akkoc, Yesim; Gerdan, Vedat; Onen, Fatos; Akkoc, Nurullah
2017-01-01
Telephone surveys are less expensive and time-consuming for both interviewers and interviewees, with similar or even higher response rates than face-to-face interviews. In rheumatology, telephone technique has been used in a number of epidemiologic studies. In the present study, we conducted a telephone survey for screening inflammatory back pain (IBP) in the community. One hundred and seventy-two patients with axial spondyloarthritis (axSpA) and 25 patients with chronic mechanical back pain were included. A telephone interview and a face-to-face interview was conducted by the same physician using a standardized questionnaire that elicited information on all the components of IBP addressed in the Calin, Berlin and ASAS (the Assessment of SpondyloArthritis International Society) criteria sets. The telephone survey was repeated by another rheumatologist within the same week to assess the inter-rater agreement. Of 172 patients with axSpA, 114 could be classified as ankylosing spondylitis (AS) according to the modified New York criteria (AS group).The remaining 58 patients had active sacroiliitis on magnetic resonance imaging and they constituted the non-radiographic axSpA group (nr-axSpA group). Calin's criteria showed the highest sensitivity but also the lowest specificity with both interview methods. Calin's criteria showed the best agreement between the interview methods (kappa = 0.60). The results of our study indicate that telephone surveys based on Calin's criteria for IBP has a moderate, almost substantial agreement with face-to-face interviews and can be used as an easily applicable, less expensive and time-saving method in screening subjects for IBP. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
NASA Technical Reports Server (NTRS)
Gernhardt, M.L.; Chappell, S.P.
2009-01-01
The EVA Physiology, Systems and Performance (EPSP) Project is performing tests in different analog environments to understand human performance during Extravehicular Activity (EVA) with the aim of developing more safe and efficient systems for lunar exploration missions and the Constellation Program. The project is characterizing human EVA performance in studies using several test beds, including the underwater NASA Extreme Environment Mission Operations (NEEMO) and Neutral Buoyancy Laboratory (NBL) facilities, JSC fs Partial Gravity Simulator (POGO), and the NASA Reduced Gravity Office (RGO) parabolic flight aircraft. Using these varied testing environments, NASA can gain a more complete understanding of human performance issues related to EVA and the limitations of each testing environment. Tests are focused on identifying and understanding the EVA system factors that affect human performance such as center of gravity (CG), inertial mass, ground reaction forces (GRF), suit weight, and suit pressure. The test results will lead to the development of lunar EVA systems operations concepts and design requirements that optimize human performance and exploration capabilities. METHODS: Tests were conducted in the NBL and during NEEMO missions in the NOAA Aquarius Habitat. A reconfigurable back pack with repositionable mass was used to simulate Perfect, Low, Forward, High, Aft and NASA Baseline CG locations. Subjects performed simulated exploration tasks that included ambulation, kneel and recovery, rock pick-up, and shoveling. Testing using POGO, that simulates partial gravity via pneumatic weight offload system and a similar reconfigurable rig, is underway for a subset of the same tasks. Additionally, test trials are being performed on the RGO parabolic flight aircraft. Subject performance was assessed using a modified Cooper-Harper scale to assess operator compensation required to achieve desired performance. All CG locations are based on the assumption of a standardized 6 ft 180 lb subject. RESULTS: The modified Cooper-Harper Scale assesses desired task performance described as performance in a reduced gravity environment as compared to a 1G environment. Modified Cooper-Harper ratings of . 3 indicate no improvements are needed, ratings of 4-6 indicate improvements are desirable, and ratings . 7 indicate improvements are mandatory. DISCUSSION: Differences were noted in suited CH results based on environment at the same CG and suit pressure. Additionally, results suggest that CG location affects unsuited human performance. Subjects preferred locations near their natural CG over those that are high, aft, or a combination of high and aft. Further testing and analyses are planned to compare these unsuited results to suited performance.
Back-Projection Imaging of extended, diffuse seismic sources in volcanic and hydrothermal systems
NASA Astrophysics Data System (ADS)
Kelly, C. L.; Lawrence, J. F.; Beroza, G. C.
2017-12-01
Volcanic and hydrothermal systems exhibit a wide range of seismicity that is directly linked to fluid and volatile activity in the subsurface and that can be indicative of imminent hazardous activity. Seismograms recorded near volcanic and hydrothermal systems typically contain "noisy" records, but in fact, these complex signals are generated by many overlapping low-magnitude displacements and pressure changes at depth. Unfortunately, excluding times of high-magnitude eruptive activity that typically occur infrequently relative to the length of a system's entire eruption cycle, these signals often have very low signal-to-noise ratios and are difficult to identify and study using established seismic analysis techniques (i.e. phase-picking, template matching). Arrays of short-period and broadband seismic sensors are proven tools for monitoring short- and long-term changes in volcanic and hydrothermal systems. Time-reversal techniques (i.e. back-projection) that are improved by additional seismic observations have been successfully applied to locating volcano-seismic sources recorded by dense sensor arrays. We present results from a new computationally efficient back-projection method that allows us to image the evolution of extended, diffuse sources of volcanic and hydrothermal seismicity. We correlate short time-window seismograms from receiver-pairs to find coherent signals and propagate them back in time to potential source locations in a 3D subsurface model. The strength of coherent seismic signal associated with any potential source-receiver-receiver geometry is equal to the correlation of the short time-windows of seismic records at appropriate time lags as determined by the velocity structure and ray paths. We stack (sum) all short time-window correlations from all receiver-pairs to determine the cumulative coherence of signals at each potential source location. Through stacking, coherent signals from extended and/or repeating sources of short-period energy radiation interfere constructively while background noise signals interfere destructively, such that the most likely source locations of the observed seismicity are illuminated. We compile results to analyze changes in the distribution and prevalence of these sources throughout a systems entire eruptive cycle.
1985-06-28
1984 to April 1985 includedr installation of 27 raw mnitor wells and 11 amh l’,(1 zjit~s, collecticn cf seive~t, sarples ftw surfac , soil, shallowv...modifying a sampling and analytical program that addresses the requirements of the project. If project requirements necessitate different quality...reagent blank and at least five (5) different concentrations of thl analyte. A modification of the method of Hubaux and Vos will be used to deter
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Following a series of acid mine drainage (AMD) projects funded largely by EPA’s Clean Water Act Section 319 non-point source program, the pH level in Aaron Run is meeting Maryland’s water quality standard – and the brook trout are back.
NASA Astrophysics Data System (ADS)
Tabrizi, Babak H.; Ghaderi, Seyed Farid
2016-09-01
Simultaneous planning of project scheduling and material procurement can improve the project execution costs. Hence, the issue has been addressed here by a mixed-integer programming model. The proposed model facilitates the procurement decisions by accounting for a number of suppliers offering a distinctive discount formula from which to purchase the required materials. It is aimed at developing schedules with the best net present value regarding the obtained benefit and costs of the project execution. A genetic algorithm is applied to deal with the problem, in addition to a modified version equipped with a variable neighbourhood search. The underlying factors of the solution methods are calibrated by the Taguchi method to obtain robust solutions. The performance of the aforementioned methods is compared for different problem sizes, in which the utilized local search proved efficient. Finally, a sensitivity analysis is carried out to check the effect of inflation on the objective function value.
Image-Based 2D Re-Projection for Attenuation Substitution in PET Neuroimaging.
Laymon, Charles M; Minhas, Davneet S; Becker, Carl R; Matan, Cristy; Oborski, Matthew J; Price, Julie C; Mountz, James M
2018-02-27
In dual modality positron emission tomography (PET)/magnetic resonance imaging (MRI), attenuation correction (AC) methods are continually improving. Although a new AC can sometimes be generated from existing MR data, its application requires a new reconstruction. We evaluate an approximate 2D projection method that allows offline image-based reprocessing. 2-Deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) brain scans were acquired (Siemens HR+) for six subjects. Attenuation data were obtained using the scanner's transmission source (SAC). Additional scanning was performed on a Siemens mMR including production of a Dixon-based MR AC (MRAC). The MRAC was imported to the HR+ and the PET data were reconstructed twice: once using native SAC (ground truth); once using the imported MRAC (imperfect AC). The re-projection method was implemented as follows. The MRAC PET was forward projected to approximately reproduce attenuation-corrected sinograms. The SAC and MRAC images were forward projected and converted to attenuation-correction factors (ACFs). The MRAC ACFs were removed from the MRAC PET sinograms by division; the SAC ACFs were applied by multiplication. The regenerated sinograms were reconstructed by filtered back projection to produce images (SUBAC PET) in which SAC has been substituted for MRAC. Ideally SUBAC PET should match SAC PET. Via coregistered T1 images, FreeSurfer (FS; MGH, Boston) was used to define a set of cortical gray matter regions of interest. Regional activity concentrations were extracted for SAC PET, MRAC PET, and SUBAC PET. SUBAC PET showed substantially smaller root mean square error than MRAC PET with averaged values of 1.5 % versus 8.1 %. Re-projection is a viable image-based method for the application of an alternate attenuation correction in neuroimaging.
NASA Astrophysics Data System (ADS)
Zhang, Xiaoxian; Crawford, John W.; Flavel, Richard J.; Young, Iain M.
2016-10-01
The Lattice Boltzmann (LB) model and X-ray computed tomography (CT) have been increasingly used in combination over the past decade to simulate water flow and chemical transport at pore scale in porous materials. Because of its limitation in resolution and the hierarchical structure of most natural soils, the X-ray CT tomography can only identify pores that are greater than its resolution and treats other pores as solid. As a result, the so-called solid phase in X-ray images may in reality be a grey phase, containing substantial connected pores capable of conducing fluids and solute. Although modified LB models have been developed to simulate fluid flow in such media, models for solute transport are relatively limited. In this paper, we propose a LB model for simulating solute transport in binary soil images containing permeable solid phase. The model is based on the single-relaxation time approach and uses a modified partial bounce-back method to describe the resistance caused by the permeable solid phase to chemical transport. We derive the relationship between the diffusion coefficient and the parameter introduced in the partial bounce-back method, and test the model against analytical solution for movement of a pulse of tracer. We also validate it against classical finite volume method for solute diffusion in a simple 2D image, and then apply the model to a soil image acquired using X-ray tomography at resolution of 30 μm in attempts to analyse how the ability of the solid phase to diffuse solute at micron-scale affects the behaviour of the solute at macro-scale after a volumetric average. Based on the simulated results, we discuss briefly the danger in interpreting experimental results using the continuum model without fully understanding the pore-scale processes, as well as the potential of using pore-scale modelling and tomography to help improve the continuum models.
Yun, Sungdae; Kyriakos, Walid E; Chung, Jun-Young; Han, Yeji; Yoo, Seung-Schik; Park, Hyunwook
2007-03-01
To develop a novel approach for calculating the accurate sensitivity profiles of phased-array coils, resulting in correction of nonuniform intensity in parallel MRI. The proposed intensity-correction method estimates the accurate sensitivity profile of each channel of the phased-array coil. The sensitivity profile is estimated by fitting a nonlinear curve to every projection view through the imaged object. The nonlinear curve-fitting efficiently obtains the low-frequency sensitivity profile by eliminating the high-frequency image contents. Filtered back-projection (FBP) is then used to compute the estimates of the sensitivity profile of each channel. The method was applied to both phantom and brain images acquired from the phased-array coil. Intensity-corrected images from the proposed method had more uniform intensity than those obtained by the commonly used sum-of-squares (SOS) approach. With the use of the proposed correction method, the intensity variation was reduced to 6.1% from 13.1% of the SOS. When the proposed approach was applied to the computation of the sensitivity maps during sensitivity encoding (SENSE) reconstruction, it outperformed the SOS approach in terms of the reconstructed image uniformity. The proposed method is more effective at correcting the intensity nonuniformity of phased-array surface-coil images than the conventional SOS method. In addition, the method was shown to be resilient to noise and was successfully applied for image reconstruction in parallel imaging.
Dynamic PET Image reconstruction for parametric imaging using the HYPR kernel method
NASA Astrophysics Data System (ADS)
Spencer, Benjamin; Qi, Jinyi; Badawi, Ramsey D.; Wang, Guobao
2017-03-01
Dynamic PET image reconstruction is a challenging problem because of the ill-conditioned nature of PET and the lowcounting statistics resulted from short time-frames in dynamic imaging. The kernel method for image reconstruction has been developed to improve image reconstruction of low-count PET data by incorporating prior information derived from high-count composite data. In contrast to most of the existing regularization-based methods, the kernel method embeds image prior information in the forward projection model and does not require an explicit regularization term in the reconstruction formula. Inspired by the existing highly constrained back-projection (HYPR) algorithm for dynamic PET image denoising, we propose in this work a new type of kernel that is simpler to implement and further improves the kernel-based dynamic PET image reconstruction. Our evaluation study using a physical phantom scan with synthetic FDG tracer kinetics has demonstrated that the new HYPR kernel-based reconstruction can achieve a better region-of-interest (ROI) bias versus standard deviation trade-off for dynamic PET parametric imaging than the post-reconstruction HYPR denoising method and the previously used nonlocal-means kernel.
NASA Astrophysics Data System (ADS)
Chang, Dong Eui; Jiménez, Fernando; Perlmutter, Matthew
2016-12-01
A new method is proposed to numerically integrate a dynamical system on a manifold such that the trajectory stably remains on the manifold and preserves the first integrals of the system. The idea is that given an initial point in the manifold we extend the dynamics from the manifold to its ambient Euclidean space and then modify the dynamics outside the intersection of the manifold and the level sets of the first integrals containing the initial point such that the intersection becomes a unique local attractor of the resultant dynamics. While the modified dynamics theoretically produces the same trajectory as the original dynamics, it yields a numerical trajectory that stably remains on the manifold and preserves the first integrals. The big merit of our method is that the modified dynamics can be integrated with any ordinary numerical integrator such as Euler or Runge-Kutta. We illustrate this method by applying it to three famous problems: the free rigid body, the Kepler problem and a perturbed Kepler problem with rotational symmetry. We also carry out simulation studies to demonstrate the excellence of our method and make comparisons with the standard projection method, a splitting method and Störmer-Verlet schemes.
Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas; Pal, Saikat; McWalter, Emily J; Beaupré, Gary S; Gold, Garry E; Fahrig, Rebecca
2014-06-01
A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjects in vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. A 2D Euclidean distance-based metric of subjects' motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.
Advanced autostereoscopic display for G-7 pilot project
NASA Astrophysics Data System (ADS)
Hattori, Tomohiko; Ishigaki, Takeo; Shimamoto, Kazuhiro; Sawaki, Akiko; Ishiguchi, Tsuneo; Kobayashi, Hiromi
1999-05-01
An advanced auto-stereoscopic display is described that permits the observation of a stereo pair by several persons simultaneously without the use of special glasses and any kind of head tracking devices for the viewers. The system is composed of a right eye system, a left eye system and a sophisticated head tracking system. In the each eye system, a transparent type color liquid crystal imaging plate is used with a special back light unit. The back light unit consists of a monochrome 2D display and a large format convex lens. The unit distributes the light of the viewers' correct each eye only. The right eye perspective system is combined with a left eye perspective system is combined with a left eye perspective system by a half mirror in order to function as a time-parallel stereoscopic system. The viewer's IR image is taken through and focused by the large format convex lens and feed back to the back light as a modulated binary half face image. The auto-stereoscopic display employs the TTL method as the accurate head tracking. The system was worked as a stereoscopic TV phone between Duke University Department Tele-medicine and Nagoya University School of Medicine Department Radiology using a high-speed digital line of GIBN. The applications are also described in this paper.
Experiences Using Lightweight Formal Methods for Requirements Modeling
NASA Technical Reports Server (NTRS)
Easterbrook, Steve; Lutz, Robyn; Covington, Rick; Kelly, John; Ampo, Yoko; Hamilton, David
1997-01-01
This paper describes three case studies in the lightweight application of formal methods to requirements modeling for spacecraft fault protection systems. The case studies differ from previously reported applications of formal methods in that formal methods were applied very early in the requirements engineering process, to validate the evolving requirements. The results were fed back into the projects, to improve the informal specifications. For each case study, we describe what methods were applied, how they were applied, how much effort was involved, and what the findings were. In all three cases, formal methods enhanced the existing verification and validation processes, by testing key properties of the evolving requirements, and helping to identify weaknesses. We conclude that the benefits gained from early modeling of unstable requirements more than outweigh the effort needed to maintain multiple representations.
DOT National Transportation Integrated Search
1995-05-01
The Oregon Department of Transportation (ODOT) installed a two-rail steel-backed timber guardrail along a section of the Historic Columbia River Highway, formerly known as the Crown Point Highway, in March 1992 as an experimental features project. Th...
NASA Astrophysics Data System (ADS)
Bianco, S.; Jones, J. A.; Gosnell, H.
2017-12-01
Process-based restoration, a new approach to river and floodplain management, is being implemented on federal lands across Oregon. These management efforts are aimed at promoting key physical processes in order to improve river ecological function, create diverse habitat, and increase biological productivity for ESA-listed bull trout and spring Chinook salmon. Although the practice is being disseminated across the Pacific Northwest, it remains unclear what is driving aquatic and riparian ecosystem restoration towards this process-based approach and away from form-based methods such as Rosgen's Natural Channel Design. The technical aspects of process-based restoration have been described in the literature (ex. Beechie et al. 2010), but little is known about the practice from a social science perspective, and few case studies exist to assess the impact of these efforts. We combine semi-structured qualitative interviews with management experts and photogrammetric analysis to better understand how complex social processes and changing ideas about aquatic ecosystems are manifesting on the ground in federal land management. This study characterizes process-based river and floodplain restoration projects on federal lands in Oregon, and identifies catalysts and barriers to its implementation. The Deer Creek Floodplain Enhancement project serves as a case study for photogrammetric analysis. To characterize long-term changes at Deer Creek, geomorphic features were mapped and classified using orthoimage mosaics developed from a time series of historic aerial photographs dating back to 1954. 3D Digital Elevation Models (3D-DEMs) were created of portions of the modified sections of Deer Creek and its floodplain immediately before and after restoration using drone-captured aerial photography and a photogrammetric technique called Structure from Motion. These 3D-DEMs have enabled extraction of first-order geomorphic variables to compare pre- and post-project conditions. This study improves understanding of the historic range of conditions at Deer Creek, and assesses how process-based restoration activities drive short-term changes in geomorphic features, which can in turn influence complex riverine processes such as energy dissipation and sediment deposition.
Energy dissipation in the blade tip region of an axial fan
NASA Astrophysics Data System (ADS)
Bizjan, B.; Milavec, M.; Širok, B.; Trenc, F.; Hočevar, M.
2016-11-01
A study of velocity and pressure fluctuations in the tip clearance flow of an axial fan is presented in this paper. Two different rotor blade tip designs were investigated: the standard one with straight blade tips and the modified one with swept-back tip winglets. Comparison of integral sound parameters indicates a significant noise level reduction for the modified blade tip design. To study the underlying mechanisms of the energy conversion and noise generation, a novel experimental method based on simultaneous measurements of local flow velocity and pressure has also been developed and is presented here. The method is based on the phase space analysis by the use of attractors, which enable more accurate identification and determination of the local flow structures and turbulent flow properties. Specific gap flow energy derived from the pressure and velocity time series was introduced as an additional attractor parameter to assess the flow energy distribution and dissipation within the phase space, and thus determines characteristic sources of the fan acoustic emission. The attractors reveal a more efficient conversion of the pressure to kinetic flow energy in the case of the modified (tip winglet) fan blade design, and also a reduction in emitted noise levels. The findings of the attractor analysis are in a good agreement with integral fan characteristics (efficiency and noise level), while offering a much more accurate and detailed representation of gap flow phenomena.
Depositing aluminum as sacrificial metal to reduce metal-graphene contact resistance
NASA Astrophysics Data System (ADS)
Da-cheng, Mao; Zhi, Jin; Shao-qing, Wang; Da-yong, Zhang; Jing-yuan, Shi; Song-ang, Peng; Xuan-yun, Wang
2016-07-01
Reducing the contact resistance without degrading the mobility property is crucial to achieve high-performance graphene field effect transistors. Also, the idea of modifying the graphene surface by etching away the deposited metal provides a new angle to achieve this goal. We exploit this idea by providing a new process method which reduces the contact resistance from 597 Ω·μm to sub 200 Ω·μm while no degradation of mobility is observed in the devices. This simple process method avoids the drawbacks of uncontrollability, ineffectiveness, and trade-off with mobility which often exist in the previously proposed methods. Project by the National Science and Technology Major Project, China (Grant No. 2011ZX02707.3), the National Natural Science Foundation of China (Grant No. 61136005), the Chinese Academy of Sciences (Grant No. KGZD-EW-303), and the Project of Beijing Municipal Science and Technology Commission, China (Grant No. Z151100003515003).
Köhn, J; Licher, J; Mielke, M; Loutfi-Krauss, B; Blümer, N; Heine, B; Rödel, C; Scherf, C; Ramm, U
2017-02-01
The use of Electronic Portal Imaging Devices (EPIDs) to acquire dosimetric information, especially for 3D-back-projection, has been increasingly extended. For a precise back-projection, the accurate knowledge of the movement characteristics of the EPID during gantry rotation is an essential requirement. Measurements were conducted with different alignments of steel balls, which were mounted on the treatment table to avoid secondary effects such as the mechanical sag of gantry or jaws. The image movement of the EPID was determined by comparing the predicted projections of the phantoms with the EPID acquired image. Effects on dosimetric verifications were evaluated by γ-evaluation. The measurement results showed that the shift of the EPID image is larger in Y direction than in X direction. A maximum rotation of 0.3° and nodding of 2.4° of the detector was calculated. Changes in SDD were found up to 10mm. The angles of nodding are overall higher at discrete gantry angles in comparison to images detected for continuous rotation. Using these results we were able to correct the EPID images used for verification measurements. γ-evaluation revealed a significantly improved agreement between planned and measured EPID signal values. The measurement methods and algorithms introduced in this study are simple and comprehensive. Using these methods and algorithms we were able to quantify the major effects on geometrical and dosimetric characteristics. This allows the correction of EPID signal measurements for these effects related to the gantry angle, leading to an improved γ-evaluation for treatment plans. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Lujie; Quan, Chenggen
2006-07-01
We have confirmed that a mathematical expression in our previous Letter [Chen and Quan, Opt. Lett.30, 2101 (2005)] should be modified. The modification, however, does not affect the validity of the method reported, the results obtained and the subsequent conclusions made.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
... Folsom DS/FDR EIS/EIR considered several methods to modify MIAD to achieve Reclamation's risk standards... availability of the Final Supplemental Environmental Impact Statement/Environmental Impact Report (EIS/EIR). SUMMARY: Pursuant to the National Environmental Policy Act and the California Environmental Quality Act...
Exact Fan-Beam Reconstruction With Arbitrary Object Translations and Truncated Projections
NASA Astrophysics Data System (ADS)
Hoskovec, Jan; Clackdoyle, Rolf; Desbat, Laurent; Rit, Simon
2016-06-01
This article proposes a new method for reconstructing two-dimensional (2D) computed tomography (CT) images from truncated and motion contaminated sinograms. The type of motion considered here is a sequence of rigid translations which are assumed to be known. The algorithm first identifies the sufficiency of angular coverage in each 2D point of the CT image to calculate the Hilbert transform from the local “virtual” trajectory which accounts for the motion and the truncation. By taking advantage of data redundancy in the full circular scan, our method expands the reconstructible region beyond the one obtained with chord-based methods. The proposed direct reconstruction algorithm is based on the Differentiated Back-Projection with Hilbert filtering (DBP-H). The motion is taken into account during backprojection which is the first step of our direct reconstruction, before taking the derivatives and inverting the finite Hilbert transform. The algorithm has been tested in a proof-of-concept study on Shepp-Logan phantom simulations with several motion cases and detector sizes.
Multispectral high-resolution hologram generation using orthographic projection images
NASA Astrophysics Data System (ADS)
Muniraj, I.; Guo, C.; Sheridan, J. T.
2016-08-01
We present a new method of synthesizing a digital hologram of three-dimensional (3D) real-world objects from multiple orthographic projection images (OPI). A high-resolution multiple perspectives of 3D objects (i.e., two dimensional elemental image array) are captured under incoherent white light using synthetic aperture integral imaging (SAII) technique and their OPIs are obtained respectively. The reference beam is then multiplied with the corresponding OPI and integrated to form a Fourier hologram. Eventually, a modified phase retrieval algorithm (GS/HIO) is applied to reconstruct the hologram. The principle is validated experimentally and the results support the feasibility of the proposed method.
A broadband high-efficiency Doherty power amplifier using symmetrical devices
NASA Astrophysics Data System (ADS)
Cheng, Zhiqun; Zhang, Ming; Li, Jiangzhou; Liu, Guohua
2018-04-01
This paper proposes a method for broadband and high-efficiency amplification of Doherty power amplifier (DPA) using symmetric devices. In order to achieve the perfect load modulation, the carrier amplifier output circuit total power length is designed to odd multiple of 90°, and the peak amplifier output total power length is designed to even multiple of 180°. The proposed method is demonstrated by designing a broadband high-efficiency DPA using identical 10-W packaged GaN HEMT devices. Measurement results show that over 51% drain efficiency is achieved at 6-dB back-off power, over the frequency band of 1.9–2.4 GHz. Project supported by the National Natural Science Foundation of China (No. 60123456), the Zhejiang Provincial Natural Science Foundation of China (No. LZ16F010001), and the Zhejiang Provincial Public Technology Research Project (No. 2016C31070).
Single-Image Distance Measurement by a Smart Mobile Device.
Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling
2017-12-01
Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.
A modified Dodge algorithm for the parabolized Navier-Stokes equations and compressible duct flows
NASA Technical Reports Server (NTRS)
Cooke, C. H.; Dwoyer, D. M.
1983-01-01
A revised version of Dodge's split-velocity method for numerical calculation of compressible duct flow was developed. The revision incorporates balancing of mass flow rates on each marching step in order to maintain front-to-back continuity during the calculation. The (checkerboard) zebra algorithm is applied to solution of the three dimensional continuity equation in conservative form. A second-order A-stable linear multistep method is employed in effecting a marching solution of the parabolized momentum equations. A checkerboard iteration is used to solve the resulting implicit nonlinear systems of finite-difference equations which govern stepwise transition. Qualitative agreement with analytical predictions and experimental results was obtained for some flows with well-known solutions. Previously announced in STAR as N82-16363
Elementary test for nonclassicality based on measurements of position and momentum
NASA Astrophysics Data System (ADS)
Fresta, Luca; Borregaard, Johannes; Sørensen, Anders S.
2015-12-01
We generalize a nonclassicality test described by Kot et al. [Phys. Rev. Lett. 108, 233601 (2012), 10.1103/PhysRevLett.108.233601], which can be used to rule out any classical description of a physical system. The test is based on measurements of quadrature operators and works by proving a contradiction with the classical description in terms of a probability distribution in phase space. As opposed to the previous work, we generalize the test to include states without rotational symmetry in phase space. Furthermore, we compare the performance of the nonclassicality test with classical tomography methods based on the inverse Radon transform, which can also be used to establish the quantum nature of a physical system. In particular, we consider a nonclassicality test based on the so-called filtered back-projection formula. We show that the general nonclassicality test is conceptually simpler, requires less assumptions on the system, and is statistically more reliable than the tests based on the filtered back-projection formula. As a specific example, we derive the optimal test for quadrature squeezed single-photon states and show that the efficiency of the test does not change with the degree of squeezing.
Boeing 747 jet modified to carry shuttle flying over Rocky Mountains
NASA Technical Reports Server (NTRS)
1977-01-01
A Boeing 747 jet aircraft, modified for use by NASA for the Space Shuttle Orbiter Approach and Landing Tests (ALTs), is seen in flight over the Rocky Mountains. Note the added structural supports atop the huge aircraft. The Shuttle Orbiter will ride 'piggy-back' atop the NASA 747 for the ALTs. The NASA 747 will be used also to transport Orbiters to the Space Shuttle launch sites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, M.K.; Narayan, R.; Han, O.
1992-01-30
The overall goal of this project is to find biological methods to remove carboxylic functionalities from low-rank coals under ambient conditions and to assess the properties of these modified coals towards coal liquefaction. The main objectives of this quarter were: (1) continuation of microbial consortia development, (2) evaluation of the isolated organisms for decarboxylation, (3) selection of best performing culture (known cultures vs. new isolates), and (4) coal decarboxylation using activated carbon as blanks. The project began on September 12, 1990.
Simulation study on ion extraction from electron cyclotron resonance ion sources
NASA Astrophysics Data System (ADS)
Fu, S.; Kitagawa, A.; Yamada, S.
1994-04-01
In order to study beam optics of NIRS-ECR ion source used in the HIMAC project, the EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1D and 2D sheath theories are used, respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source are presented in this paper, exhibiting an agreement with the experiment results.
["Back pain coach". A project for patients with back pain].
Lindena, G; Marnitz, U; Hartmann, P; Müller, G
2012-12-01
Back pain is a challenge for case management but is a health insurance fund (HIF) that identifies high risk patients and includes them in a back pain assessment and a multimodal program cost-effective? Case managers of a HIF contacted selected patients and requested information on pain and current perspectives. Patients in the intervention group were offered a multimodal assessment and, if applicable, a multimodal treatment program. Control group patients received verbal or written (back book) information. Cost data were evaluated with respect to the interview data 1 year prior and 1 year afterwards. Of the 800 insured persons contacted 621 were nationwide, 88 were regional controls and 91 were intervention patients. Inability to work was still rising in all groups but less in the intervention group versus both control groups. Drugs, hospital as well as cure/adjuvant costs were less for intervention patients than in both control groups. The investment for the program was thus more than refinanced. Case management was well accepted but the intervention was in need of training for case managers and the specific diagnostic and treatment option regionally. The HIF was responsible for the study investment and project partners shared the training of the HIF regional case managers.
Zhao, Lu; Xie, Jingqian; Guo, Fangjie; Liu, Kai
2018-05-01
Supercritical fluid chromatography (SFC) is already used for enantioseparation in the pharmaceutical industry, but it is rarely used for the separation of chiral pesticides. Comparing with high performence liquid chromatography, SFC uses much more environmnetal friendly and economic mobile phase, supercritical CO 2 . In our work, the enantioseparation of an amide herbicide, napropamide, using three different polysaccharide-type chiral stationary phases (CSPs) in SFC was investigated. By studying the effect of different CSPs, organic modifiers, temperature, back-pressure regulator pressures, and flow rates for the enantioseparation of napropamide, we established a rapid and green method for enantioseparation that takes less than 2 minutes: The column was CEL2, the mobile phase was CO 2 with 20% 2-propanol, and the flow rate was 2.0 mL/min. We found that CEL2 demonstrated the strongest resolution capability. Acetonitrile was favored over alcoholic solvents when the CSP was amylose and 2-propanol was the best choice when using cellulose. When the concentration of the modifiers or the flow rate was decreased, resolutions and analysis times increased concurrently. The temperature and back-pressure regulator pressure exhibited only minor influences on the resolution and analysis time of the napropamide enantioseparations with these chiral columns. The molecular docking analysis provided a deeper insight into the interactions between the enantiomers and the CSPs at the atomic level and partly explained the reason for the different elution orders using the different chiral columns. © 2018 Wiley Periodicals, Inc.
Gate Tunable Transport in Graphene/MoS₂/(Cr/Au) Vertical Field-Effect Transistors.
Nazir, Ghazanfar; Khan, Muhammad Farooq; Aftab, Sikandar; Afzal, Amir Muhammad; Dastgeer, Ghulam; Rehman, Malik Abdul; Seo, Yongho; Eom, Jonghwa
2017-12-28
Two-dimensional materials based vertical field-effect transistors have been widely studied due to their useful applications in industry. In the present study, we fabricate graphene/MoS₂/(Cr/Au) vertical transistor based on the mechanical exfoliation and dry transfer method. Since the bottom electrode was made of monolayer graphene (Gr), the electrical transport in our Gr/MoS₂/(Cr/Au) vertical transistors can be significantly modified by using back-gate voltage. Schottky barrier height at the interface between Gr and MoS₂ can be modified by back-gate voltage and the current bias. Vertical resistance (R vert ) of a Gr/MoS₂/(Cr/Au) transistor is compared with planar resistance (R planar ) of a conventional lateral MoS₂ field-effect transistor. We have also studied electrical properties for various thicknesses of MoS₂ channels in both vertical and lateral transistors. As the thickness of MoS₂ increases, R vert increases, but R planar decreases. The increase of R vert in the thicker MoS₂ film is attributed to the interlayer resistance in the vertical direction. However, R planar shows a lower value for a thicker MoS₂ film because of an excess of charge carriers available in upper layers connected directly to source/drain contacts that limits the conduction through layers closed to source/drain electrodes. Hence, interlayer resistance associated with these layers contributes to planer resistance in contrast to vertical devices in which all layers contribute interlayer resistance.
Modified screening and ranking algorithm for copy number variation detection.
Xiao, Feifei; Min, Xiaoyi; Zhang, Heping
2015-05-01
Copy number variation (CNV) is a type of structural variation, usually defined as genomic segments that are 1 kb or larger, which present variable copy numbers when compared with a reference genome. The screening and ranking algorithm (SaRa) was recently proposed as an efficient approach for multiple change-points detection, which can be applied to CNV detection. However, some practical issues arise from application of SaRa to single nucleotide polymorphism data. In this study, we propose a modified SaRa on CNV detection to address these issues. First, we use the quantile normalization on the original intensities to guarantee that the normal mean model-based SaRa is a robust method. Second, a novel normal mixture model coupled with a modified Bayesian information criterion is proposed for candidate change-point selection and further clustering the potential CNV segments to copy number states. Simulations revealed that the modified SaRa became a robust method for identifying change-points and achieved better performance than the circular binary segmentation (CBS) method. By applying the modified SaRa to real data from the HapMap project, we illustrated its performance on detecting CNV segments. In conclusion, our modified SaRa method improves SaRa theoretically and numerically, for identifying CNVs with high-throughput genotyping data. The modSaRa package is implemented in R program and freely available at http://c2s2.yale.edu/software/modSaRa. Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Carbon Back Sputter Modeling for Hall Thruster Testing
NASA Technical Reports Server (NTRS)
Gilland, James H.; Williams, George J.; Burt, Jonathan M.; Yim, John T.
2016-01-01
In support of wear testing for the Hall Effect Rocket with Magnetic Shielding (HERMeS) program, the back sputter from a Hall effect thruster plume has been modeled for the NASA Glenn Research Centers Vacuum Facility 5. The predicted wear at a near-worst case condition of 600 V, 12.5 kW was found to be on the order of 3 4 mkhour in a fully carbon-lined chamber. A more detailed numerical monte carlo code was also modified to estimate back sputter for a detailed facility and pumping configuration. This code demonstrated similar back sputter rate distributions, but is not yet accurately modeling the magnitudes. The modeling has been benchmarked to recent HERMeS wear testing, using multiple microbalance measurements. These recent measurements have yielded values, on the order of 1.5- 2 microns/khour.
NASA Astrophysics Data System (ADS)
Ren, Zhong; Liu, Guodong; Huang, Zhen
2012-11-01
The image reconstruction is a key step in medical imaging (MI) and its algorithm's performance determinates the quality and resolution of reconstructed image. Although some algorithms have been used, filter back-projection (FBP) algorithm is still the classical and commonly-used algorithm in clinical MI. In FBP algorithm, filtering of original projection data is a key step in order to overcome artifact of the reconstructed image. Since simple using of classical filters, such as Shepp-Logan (SL), Ram-Lak (RL) filter have some drawbacks and limitations in practice, especially for the projection data polluted by non-stationary random noises. So, an improved wavelet denoising combined with parallel-beam FBP algorithm is used to enhance the quality of reconstructed image in this paper. In the experiments, the reconstructed effects were compared between the improved wavelet denoising and others (directly FBP, mean filter combined FBP and median filter combined FBP method). To determine the optimum reconstruction effect, different algorithms, and different wavelet bases combined with three filters were respectively test. Experimental results show the reconstruction effect of improved FBP algorithm is better than that of others. Comparing the results of different algorithms based on two evaluation standards i.e. mean-square error (MSE), peak-to-peak signal-noise ratio (PSNR), it was found that the reconstructed effects of the improved FBP based on db2 and Hanning filter at decomposition scale 2 was best, its MSE value was less and the PSNR value was higher than others. Therefore, this improved FBP algorithm has potential value in the medical imaging.
Determination of linsidomine in human plasma by tandem LC-MS with ESI.
Sutherland, F C; de Jager, A D; Swart, K J; Hundt, H K; Scanes, T; Hundt, A F
2000-04-01
A sensitive method for the determination of linsidomine in plasma was developed, using high-performance liquid chromatographic (HPLC) separation with tandem mass spectrometric detection. Linsidomine was derivatised with propyl chloroformate and extracted with tert-butyl methyl ether/1,2-dichloroethane (55:45, v/v), back-extracted into HCl (0.01 M) followed by alkalinisation and back-extraction into ether; the final ether extract evaporated, reconstituted in mobile phase and then separated on a Phenomenex Luna C18 (2) 5 micron 2.1 x 150 mm column with a mobile phase consisting of methanol water formic acid (98/100%) (400:600:0.05, v/v/v) at a flow-rate of 0.4 ml min(-1). Detection was achieved by a Finnigan MAT mass spectrometer (LCQ) at unit resolution in the selected reaction monitoring (SRM) mode monitoring the transition of the protonated molecular ion m/z 257.0 to the product ion m/z 86.0. The mean recovery for linsidomine was 51% with a lower limit of quantification of 0.70 ng/ml using 1 ml plasma for extraction. This LC-MS/MS method for the determination of linsidomine in human plasma allows for better specificity and a higher sample throughput than the traditional LC-UV methods. It also demonstrates the profound effect that the composition of acidic modifiers and matrix constituents can have on the electrospray ionisation (ESI) of the analyte.
Ahmed, Omar; Dhinsa, Amrita; Popenko, Natalie; Osann, Kathryn; Crumley, Roger L; Wong, Brian J
2014-01-01
There is no universally accepted quantitative metric that defines the ideal nasal tip rotation and projection. To identify the ideal nasal tip projection (NTP) and rotation by using 3 classic NTP methods (Crumley 1, Crumley 2, and Goode). Lateral facial portraits of normal-appearing white women aged 18 to 25 years were selected from a previously validated and attractiveness-scored database of images. Each image was digitally modified to fit the NTP ideals outlined by the Crumley 1, Crumley 2, and Goode methods with columellar facial angles (rotation metric) of 96°, 101°, 106°, 111°, and 116° (15 modified images per portrait). These variants were incorporated into electronic surveys that were distributed to traditional focus-group and online social-network participants. Analysis was performed using paired comparison analysis, a consumer preference research analytic. The traditional focus-group participants were undergraduate students at the University of California, Irvine, whose online social-network contacts were also used. Mean ranks. There were no significant differences in preference between the traditional focus-group (n = 106) and online participants (n = 3872) (P > .05). The most preferred rotation variant for all 3 NTP methods was 106° (Crumley 1: mean rank, 2.11 [95% CI, 2.07-2.16]; Crumley 2: mean rank, 2.07 [95% CI, 2.02-2.12]; and Goode: mean rank, 2.05 [95% CI, 1.99-2.11]; P < .001). Crumley 1 was considered to be the most attractive NTP method (mean rank, 1.84 [95% CI, 1.82-1.85]; P < .001) overall and was the most preferred NTP method for faces of above-average attractiveness (mean rank, 1.78 [95% CI, 1.76-1.80]; P < .001). No significantly preferred NTP method was found for faces of average attractiveness (P > .05). The most aesthetic combination of tip rotation and projection was a columellar facial angle of 106° with the Crumley 1 tip projection. To our knowledge, this is the first population-based study to attempt to simultaneously determine the ideal NTP and rotation. Each classic NTP method uses measurements dependent on both projection and rotation; thus, ideal rotation for each NTP method must be determined before comparison of the ideals. A rotation of 106° (columellar facial angle) was found to be the most aesthetic. The Crumley 1 method was determined to be the most attractive nasal tip variant overall. NA.
Maki, Dana; Rajab, Ebrahim; Watson, Paul J; Critchley, Duncan J
2017-02-01
Purpose To translate and cross-culturally adapt the Back Beliefs Questionnaire (BBQ) into modern standard Arabic and examine its validity, acceptability and reliability in Arabic-speaking patients with low back pain (LBP). Method The BBQ was forward, back-translated and reviewed by an expert committee. Seventeen bilingual patients completed Arabic and English BBQs. LBP patients (n = 199) completed the Arabic BBQ. Sixty-four repeated it a week later, and 151 completed the Arabic Fear-avoidance Beliefs Questionnaire (FABQ). Results The expert committee followed advice from the developers to maintain Arabic equivalence of "back trouble(s)". Patients found the questionnaire comprehensible and acceptable. Agreement between the English and Arabic versions of the BBQ was acceptable, ICC = 0.65 (0.25-0.86). Most item-by-item agreement ranged from fair to moderate (K = 0.12-0.54). Mean (SD) of BBQ, FABQ total, work and physical activity subscales were 25.31(6.13), 44.76(19.49), 21.17(10.10) and 13.95(6.65). The BBQ correlated with the FABQ at r = -0.33, work subscale r = -0.29 and physical activity r = -0.30 (all p < 0.01). Cronbach's α = 0.73 indicated high internal consistency. Test-retest reliability was high, ICC = 0.80 (0.68-0.87). Item-by-item agreement ranged from fair to acceptable (K = 0.31-0.66). Conclusions The Arabic BBQ has good comprehensibility and acceptability, acceptable agreement with the English BBQ, high internal consistency and test-retest reliability. We recommend its use with Arabic-speaking LBP patient to determine their beliefs and attitudes about their back pain, as they have been shown to be important predictors of persistent LBP disability. Implications for Rehabilitation There are limited valid and reliable outcome measures for back pain in Arabic. The Back Beliefs Questionnaire (BBQ) is a tool that measures attitudes and beliefs about back pain. We recommend the use of our valid and reliable, translated and cross-culturally adapted tool with Arabic-speaking patients. The tool can measure attitudes and beliefs concerning the future consequences of LBP, with regards to recovery and return to work in this sample. Findings will improve back pain management options aimed at reducing back pain disability though challenging and modifying beliefs in the Middle East or with migrant populations in the West.
A guide to federal-aid programs and projects
DOT National Transportation Integrated Search
1999-05-01
This guide provides basic information about Federal-aid programs, projects, and other program characteristics. The information sheets contained in the guide provide fiscal information, statutory and regulatory references, general eligibility and back...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uyttenhove, W.; Baeten, P.; Kochetkov, A.
The GUINEVERE (Generation of Uninterrupted Intense Neutron pulses at the lead Venus Reactor) project was launched in 2006 within the framework of FP6 EUROTRANS in order to validate online reactivity monitoring and subcriticality level determination in accelerator driven systems (ADS). Therefore, the VENUS reactor at SCK.CEN in Mol, Belgium, was modified towards a fast core (VENUS-F) and coupled to the GENEPI-3C accelerator built by CNRS. The accelerator can operate in both continuous and pulsed mode. The VENUS-F core is loaded with enriched Uranium and reflected with solid lead. A well-chosen critical reference state is indispensable for the validation of themore » online subcriticality monitoring methodology. Moreover, a benchmarking tool is required for nuclear data research and code validation. In this paper, the design and the importance of the critical reference state for the GUINEVERE project are motivated. The results of the first experimental phase on the critical core are presented. The control rods worth is determined by the positive period method and the application of the Modified Source Multiplication (MSM) method allows the determination of the worth of the safety rods. The results are implemented in the VENUS-F core certificate for full exploitation of the critical core. (authors)« less
Imaging and virtual autopsy: looking back and forward
Bolliger, Stephan A.; Thali, Michael J.
2015-01-01
In order to create a three-dimensional (3D) documentation of findings which can be reassessed if necessary by other experts, the research project ‘Virtopsy®’ was launched in the late 1990s. This project combined autopsy results with forensic imaging in the form of computed tomography, magnetic resonance tomography and 3D surface scanning. The success of this project eventually succeeded in convincing the courts in Switzerland to accept these novel methods as evidence. As opposition towards autopsies has grown over the last decades, Virtopsy also strives to find and elaborate additional methods which can answer the main forensic questions without autopsy. These methods comprise post-mortem angiography for illustration of the vascular bed and image-guided tissue and fluid sampling for histological, toxicological and microbiological examinations. Based on the promising results, post-mortem imaging, especially with 3D surface scanning, has meanwhile also been applied to living victims of assault, who have suffered patterned injuries due to bites, blows with objects, etc. In our opinion, forensic imaging is an objective method which offers the possibility for a reassessment of the findings by other experts, even after burial or cremation of the corpse, or healing of the injuries in living victims, thus leading to a greater security in court. PMID:26101279
NASA Technical Reports Server (NTRS)
Greening, Gage J.
2016-01-01
The Project Management and Engineering Branch (SF4) supports the Human Health and Performance Directorate (HH&P) and is responsible for developing and supporting human systems hardware for the International Space Station (ISS). When a principal investigator's (PI) medical research project on the ISS is accepted, SF4 develops the necessary hardware and software to transport to the ISS. The two projects I primarily worked on were the centrifuge and ultrasound projects. Centrifuge: One concern with spacecraft such as the ISS is electromagnetic interference (EMI) from onboard equipment, typically from radio waves (frequencies of 3 kHz to 300 GHz), which can negatively affect nearby circuitry. Standard commercial centrifuges produce EMI above safety limits, so my task was to help reduce EMI production from this equipment. Two centrifuges were tested: one unmodified as a control and one modified. To reduce EMI below safety limits, one centrifuge was modified to become a Faraday shield, in which significant electrical contact was made between all regions of the centrifuge housing. This included removing non-conductive paint, applying conductive fabric to the lid and foam sealer, adding a 10,000 µF decoupling capacitor across the power supply, and adding copper adhesive-mount gaskets to the housing interior. EMI testing of both centrifuges was performed in the EMI/EMC Control Test and Measurement Facility. EMI for both centrifuges was below safety limits for frequencies between 10 MHz and 15 GHz (pass); however, between 14 kHz and 10 MHz, EMI for the unmodified centrifuge exceeded safety limits (fail) as expected. Alternatively, for the modified centrifuge with the Faraday shield, EMI was below the safely limit of 55 dBµV/m for electromagnetic frequencies between 14 kHz and 10 MHz. This result indicates our modifications were successful. The successful EMI test allowed us to communicate with the vendor what modifications they needed to make to their commercial unit to meet our specifications and to understand what needs to be done in lab to the new centrifuge. Our modifications will provide a standard for readying centrifuges for future missions. Once the new modified centrifuge arrives by the vendor, it will need to undergo EMI testing again for validation. The centrifuge is also in the process of compatibility testing with a custom stowage drawer, which is an ongoing project in SF4. Both of these items will be payloads on future missions to the ISS for various research purposes. Ultrasound: ISS currently has an onboard ultrasound (Ultrasound 2 system) for research and medical purposes. Every piece of medical flight hardware has an equivalent ground-unit so instrumentation can be routinely evaluated and transported to the ISS if necessary. The ground-unit ultrasound equipment must be evaluated every six months using a task performance sheet (TPS). A TPS is a document, written by the appropriate scientists and engineers, which describes how to run equipment and is written in such a way that astronauts with unspecialized training can follow the tasks. I was responsible for performing six TPSs on a combination of three ultrasounds and two video power converters (VPCs). Performing a TPS involves checking out and computationally documenting each piece of equipment removed from storage locations, setting up hardware and software, performing tasks to verify functionality, returning equipment, and logging items back into the computerized system. My work revealed all ground-unit ultrasounds were functioning properly. Because of proper function, a discrepancy report (DR) did not have to be opened. The TPS was then passed along to the Quality Engineering (QE) for review and ultimately given to Quality Assurance (QA). Other projects: In addition to my main projects, I participated in other tasks including troubleshooting an EEG headband, volunteering for an ultrasound training research study, and conformal coating printed circuit boards. My internship at SF4 has helped me understand how space systems hardware development for the ISS fits into NASA's mission and vision.
Milosavljevic, Stephan
2017-01-01
Introduction Low back pain (LBP) is the most common, costly and disabling musculoskeletal disorder worldwide, and is prevalent in healthcare workers. Posture is a modifiable risk factor for LBP shown to reduce the prevalence of LBP. Our feasibility research suggests that postural feedback might help healthcare workers avoid hazardous postures. The Effectiveness of Lumbopelvic Feedback (ELF) trial will investigate the extent to which postural monitor and feedback (PMF) can reduce exposure to hazardous posture associated with LBP. Methods This is a participant-blinded, randomised controlled trial with blocked cluster random allocation. Participants will include volunteer healthcare workers recruited from aged care institutions and hospitals. A postural monitoring and feedback device will monitor and record lumbopelvic forward bending posture, and provide audio feedback whenever the user sustains a lumbopelvic forward bending posture that exceeds predefined thresholds. The primary outcome measure will be postural behaviour (exceeding thresholds). Secondary outcome measures will be incidence of LBP, participant-reported disability and adherence. Following baseline assessment, we will randomly assign participants to 1 of 2 intervention arms: a feedback group and a no-feedback control group. We will compare between-group differences of changes in postural behaviour by using a repeated measures mixed-effect model analysis of covariance (ANCOVA) at 6 weeks. Postural behaviour baseline scores, work-related psychosocial factors and disability scores will be input as covariates into the statistical models. We will use logistic mixed model analysis and Cox's proportional hazards for assessing the effect of a PMF on LBP incidence between groups. Discussion Posture is a modifiable risk factor for low back disorders. Findings from the ELF trial will inform the design of future clinical trials assessing the effectiveness of wearable technology on minimising hazardous posture during daily living activities in patients with low back disorders. Trial registration number ACTRN12616000449437. PMID:28073798
Hedden, Sarra L; Woolson, Robert F; Carter, Rickey E; Palesch, Yuko; Upadhyaya, Himanshu P; Malcolm, Robert J
2009-07-01
"Loss to follow-up" can be substantial in substance abuse clinical trials. When extensive losses to follow-up occur, one must cautiously analyze and interpret the findings of a research study. Aims of this project were to introduce the types of missing data mechanisms and describe several methods for analyzing data with loss to follow-up. Furthermore, a simulation study compared Type I error and power of several methods when missing data amount and mechanism varies. Methods compared were the following: Last observation carried forward (LOCF), multiple imputation (MI), modified stratified summary statistics (SSS), and mixed effects models. Results demonstrated nominal Type I error for all methods; power was high for all methods except LOCF. Mixed effect model, modified SSS, and MI are generally recommended for use; however, many methods require that the data are missing at random or missing completely at random (i.e., "ignorable"). If the missing data are presumed to be nonignorable, a sensitivity analysis is recommended.
Processing multiphoton states through operation on a single photon: Methods and applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin Qing; He Bing; Bergou, Janos A.
2009-10-15
Multiphoton states are widely applied in quantum information technology. By the methods presented in this paper, the structure of a multiphoton state in the form of multiple single-photon qubit products can be mapped to a single-photon qudit, which could also be in a separable product with other photons. This makes possible the manipulation of such multiphoton states by processing single-photon states. The optical realization of unknown qubit discrimination [B. He, J. A. Bergou, and Y.-H. Ren, Phys. Rev. A 76, 032301 (2007)] is simplified with the transformation methods. Another application is the construction of quantum logic gates, where the inversemore » transformations back to the input state spaces are also necessary. We especially show that the modified setups to implement the transformations can realize the deterministic multicontrol gates (including Toffoli gate) operating directly on the products of single-photon qubits.« less
Study protocol: The back pain outcomes using longitudinal data (BOLD) registry
2012-01-01
Background Back pain is one of the most important causes of functional limitation, disability, and utilization of health care resources for adults of all ages, but especially among older adults. Despite the high prevalence of back pain in this population, important questions remain unanswered regarding the comparative effectiveness of commonly used diagnostic tests and treatments in the elderly. The overall goal of the Back pain Outcomes using Longitudinal Data (BOLD) project is to establish a rich, sustainable registry to describe the natural history and evaluate prospectively the effectiveness, safety, and cost-effectiveness of interventions for patients 65 and older with back pain. Methods/design BOLD is enrolling 5,000 patients ≥ 65 years old who present to a primary care physician with a new episode of back pain. We are recruiting study participants from three integrated health systems (Kaiser-Permanente Northern California, Henry Ford Health System in Detroit and Harvard Vanguard Medical Associates/ Harvard Pilgrim Health Care in Boston). Registry patients complete validated, standardized measures of pain, back pain-related disability, and health-related quality of life at enrollment and 3, 6 and 12 months later. We also have available for analysis the clinical and administrative data in the participating health systems’ electronic medical records. Using registry data, we will conduct an observational cohort study of early imaging compared to no early imaging among patients with new episodes of back pain. The aims are to: 1) identify predictors of early imaging and; 2) compare pain, functional outcomes, diagnostic testing and treatment utilization of patients who receive early imaging versus patients who do not receive early imaging. In terms of predictors, we will examine patient factors as well as physician factors. Discussion By establishing the BOLD registry, we are creating a resource that contains patient-reported outcome measures as well as electronic medical record data for elderly patients with back pain. The richness of our data will allow better matching for comparative effectiveness studies than is currently possible with existing datasets. BOLD will enrich the existing knowledge base regarding back pain in the elderly to help clinicians and patients make informed, evidence-based decisions regarding their care. PMID:22554166
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.
2010-09-15
Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selectedmore » from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.« less
3D mapping of breast surface using digital fringe projection
NASA Astrophysics Data System (ADS)
Vairavan, Rajendaran; Retnasamy, Vithyacharan; Mohamad Shahimin, Mukhzeer; Sauli, Zaliman; Leng, Lai Siang; Wan Norhaimi, Wan Mokhzani; Marimuthu, Rajeswaran; Abdullah, Othman; Kirtsaeng, Supap
2017-02-01
Optical sensing technique has inherited non-contact nature for generating 3D surface mapping where its application ranges from MEMS component characterization, corrosion analysis, and vibration analysis. In particular, the digital fringe projection is utilized for 3D mapping of objects through the illumination of structured light for medical application extending from oral dental measurements, lower back deformation analysis, monitoring of scoliosis and 3D face reconstruction for biometric identification. However, the usage of digital fringe projection for 3D mapping of human breast is very minimal. Thus, this paper addresses the application of digital fringe projection for 3D mapping of breast surface based on total non-contact nature. In this work, phase shift method is utilized to perform the 3D mapping. The phase shifted fringe pattern are displayed through a digital projector onto the breast surface, and the distorted fringe patterns are captured by a CCD camera. A phase map is produced, and phase unwrapping was executed to obtain the 3D surface mapping of the breast. The surface height profile from 3D fringe projection was compared with the surface height measured by a direct method using electronic digital vernier caliper. Preliminary results showed the feasibility of digital fringe projection in providing a 3D mapping of breast and its application could be further extended for breast carcinoma detection.
Factors affecting recovery from work-related, low back disorders in autoworkers.
Oleske, Denise M; Neelakantan, Janani; Andersson, Gunnar B; Hinrichs, Bradley G; Lavender, Steven A; Morrissey, Mary J; Zold-Kilbourn, Phyllis; Taylor, Emily
2004-08-01
To simultaneously evaluate personal, medical, and job factors that could affect recovery from work-related, low back disorders, specifically focusing on an active working sample. Observational, longitudinal study. Two US automotive plants. Employees (N=352; 289 men, 63 women; mean age +/- standard deviation, 45.1+/-7.5 y) who were active hourly autoworkers, diagnosed with work-related, low back disorder by the plant's medical department. Not applicable. Oswestry Disability Questionnaire for back pain was used to evaluate recovery. Factors associated with better recovery were lower stress levels (P<.001) and exercise or physical activity outside work (P<.001); factors associated with higher disability levels over time were current cigarette smoking (P<.01) and bedrest (P<.001). Personal modifiable factors are major influences in the recovery from work-related, low back disorders, even in active working populations. Interventions aimed at increasing exercise and decreasing stress should also be considered as a part of rehabilitation in employed persons with low levels of disability.
NASA Astrophysics Data System (ADS)
Sheikhan, Mansour; Abbasnezhad Arabi, Mahdi; Gharavian, Davood
2015-10-01
Artificial neural networks are efficient models in pattern recognition applications, but their performance is dependent on employing suitable structure and connection weights. This study used a hybrid method for obtaining the optimal weight set and architecture of a recurrent neural emotion classifier based on gravitational search algorithm (GSA) and its binary version (BGSA), respectively. By considering the features of speech signal that were related to prosody, voice quality, and spectrum, a rich feature set was constructed. To select more efficient features, a fast feature selection method was employed. The performance of the proposed hybrid GSA-BGSA method was compared with similar hybrid methods based on particle swarm optimisation (PSO) algorithm and its binary version, PSO and discrete firefly algorithm, and hybrid of error back-propagation and genetic algorithm that were used for optimisation. Experimental tests on Berlin emotional database demonstrated the superior performance of the proposed method using a lighter network structure.
NASA Astrophysics Data System (ADS)
Bencze, Larry; Hewitt, Jim; Pedretti, Erminia
2009-01-01
Results of various studies suggest that multimedia ‘case methods’ (activities associated with case documentaries) have many benefits in university-based teacher education contexts. They can, for example, help to ‘bridge the gap’ between perspectives and practices held by academic teacher educators and those held by student-teachers - who may adhere to perspectives and practices commonly supported in schools. On the other hand, some studies, along with theoretical arguments, suggest that there are limits to the effectiveness of multimedia case methods - because, for example, they can never fully represent realities of teaching and learning in schools. Furthermore, often missing from multimedia case methods is the student-teacher in the role of teacher. To address these concerns, we modified an existing multimedia case method by associating it with a special practice teaching situation in a school context. Qualitative data analyzed using constant comparative methods suggest that student-teachers engaged in this modified multimedia case method developed relatively deep commitments to encouraging students to conduct technology design projects - a non-traditional practice in school science. Factors that appeared to influence development of this motivation included student-teachers’ pre-instructional perspectives about science and the personalization and contextualization inherent to the modified multimedia case method.
Peters, S; Schultze, A; Pfeifer, K; Faller, H; Meng, K
2016-03-01
The transfer of standardised patient education programmes into practice is a complex process with a multitude of influencing factors. Determinants relate among others to the organisation and individuals (e. g., practitioner, patient). Knowledge about individual factors regarding the trainers of patient education programmes in the German rehabilitation system is scarce. The aim of this study is to explore the acceptance of trainers concerning the implementation of a standardised back school and to derive facilitators and barriers to the implementation of patient education programmes. Semi-structured guideline-based interviews were conducted in 10 rehabilitation clinics. The sample consisted of 46 trainers (25 women): 11 physicians, 11 psychologists, 21 physio-/exercise therapists and 3 occupational therapists with a mean age of 41. The opinions of the trainers regarding the central components of back schools in general, their opinions about the new curriculum, their expectations on its implementation, anticipated difficulties with implementation and requests to the project team were explored as indicators for acceptance. The data were analysed with a multi-step qualitative content analysis. 6 main categories comprising 136 subcategories were created and 729 quotations coded. Regarding the central components that should be covered by back schools, back-friendly behaviour was addressed most often. Opinions regarding the new curriculum were mostly positive. Trainers' approval of content and methods was highlighted and the similarity with existing offers in the clinics as well as the structure of the programme were rated positively. The trainers expected an increased patient orientation and personal development as well as a common, coherent language and interdisciplinarity. Difficulties were anticipated regarding time and personnel as well as therapy and appointment planning and also regarding the motivation/acceptance of patients. A wish for communication, education of trainers and feedback was directed at the project team. The study demonstrates high acceptance of programme implementation and central components of modern patient education programmes among trainers. The basis of individual facilitators and barriers has been investigated and might contribute to further development of implementation interventions. Communication and education considering those factors play a central role. © Georg Thieme Verlag KG Stuttgart · New York.
A projection method for coupling two-phase VOF and fluid structure interaction simulations
NASA Astrophysics Data System (ADS)
Cerroni, Daniele; Da Vià, Roberto; Manservisi, Sandro
2018-02-01
The study of Multiphase Fluid Structure Interaction (MFSI) is becoming of great interest in many engineering applications. In this work we propose a new algorithm for coupling a FSI problem to a multiphase interface advection problem. An unstructured computational grid and a Cartesian mesh are used for the FSI and the VOF problem, respectively. The coupling between these two different grids is obtained by interpolating the velocity field into the Cartesian grid through a projection operator that can take into account the natural movement of the FSI domain. The piecewise color function is interpolated back on the unstructured grid with a Galerkin interpolation to obtain a point-wise function which allows the direct computation of the surface tension forces.
High Frequency Infrasonic Radiation from the 11 March 2011 Tohoku Mw 9.0 Earthquake
NASA Astrophysics Data System (ADS)
Walker, K. T.; Le Pichon, A.; Degroot-Hedlin, C. D.; Che, I.
2011-12-01
The tragic March 11 Mw 9.0 Tohoku earthquake ruptured the Wadati-Benioff zone beneath northeast Japan, generating a damaging seismic wavetrain and triggering a tsunami that devastated the nearby coastal areas. Centroid moment tensors, aftershocks, and the geometry of the trench suggest the rupture occurred on a plane roughly 400 km long by 200 km wide. Because the Earth's surface is effectively a speaker, the seismic wavetrain generated infrasonic emissions from northeast Japan that were recorded by seven infrasound arrays within 5600 km of the epicenter. Using a time progressive beamforming method and the Progressive Multi-Channel Correlation method, we detect and calculate back azimuths for the 0.3 to 3 Hz infrasonic signals at these stations. After application of predicted wind corrections, these back azimuths point to Honshu and Hokkaido, with the majority of detections illuminating a north-south elongated area near Sendai, where the USGS ShakeMap predicts the greatest intensity of surface shaking. An array near Tokyo (IS30) provides the first recording of locally generated infrasound from a very large dip-slip earthquake. At IS30 a six-minute arrival in the 0.3 to 1.5 Hz band is observed from northeast Japan spanning an 18° back azimuth range. Two shorter events originate from a source to the west, likely Mt. Fuji. Using constraints from propagation modeling, we back project the infrasonic amplitudes recorded at IS30 to a relatively localized area. The maximum amplitude of 1 Pa originates from surface shaking along the coast. This location is also just west of the epicenter and adjacent to the location of maximum P-wave radiation from back projection studies. Noise at IS30 after the mainshock limits the detection of additional signals. A more pronounced infrasonic wavetrain at IS44 (Kamchatka) illuminates the entire Honshu and Hokkaido region, especially along the east coast near Sendai. In agreement with propagation modeling predictions using global atmospheric velocity models, far-field stratospheric and thermospheric arrivals are detected to the northeast and west of the epicenter along the two approximate source-receiver planes. The northeast stations demonstrate a remarkably consistent amplitude decay with range (R) typical of spherical spreading (20log10{R}) whereas the western stations also experience a remarkably consistent decay, but one that is much greater (35log10{R}), likely due to thermospheric attenuation. Our results show that infrasonic arrays listening in regions of very large earthquakes can provide direct measurements of surface shaking, which is pertinent to the timely creation of accurate ShakeMaps.
Liu, Bao-Xin; Chen, Shu-Peng; Li, Yu-Dong; Wang, Ji; Zhang, Bin; Lin, Ying; Guan, Jun-Hui; Cai, Ying-Feng; Liang, Zhu; Zheng, Fang
2015-01-01
Abstract Osteoporosis and related fragility fractures represent a serious and global public health problem. To evaluate whether the modified eighth section of Eight-section Brocade (MESE) exercise could improve the symptom and indexes associated with osteoporosis in postmenopausal women. Guangzhou and Liuzhou hospital of traditional Chinese medicine in China. Women (n = 198) aged 50 to 75 years were randomized into Control, Ca, MESE, and MESE + Ca. Subjects in Ca and MESE groups were separately asked to consume thrice daily Calcium Carbonate Chewable D3 tablet and to perform thrice daily MESE exercise by 7 repetitions per time for 12 months. Subjects in MESE + Ca group performed such the combined treatment project for 12 months. Body height and Hospital for Special Surgery (HSS) scores of both knees, chronic back pain visual analogue scale scores (VAS), bone mineral density (BMD) at L2 to L4 and the left femoral neck, 3-feet Up and Go Test (3′) and one-leg Stance (OLS). In our study, the improvement in chronic back pain of the patients in Ca, MESE, and MESE + Ca group was better than that in control group. There was 1.9% and 1.7%, 2.3%, and 2.1% net profit in left femoral neck and lumbar BMD after the treatment for 12 months in MESE and MESE + Ca groups. For the balance capacity, the subjects in MESE and MESE + Ca groups secured much better performance than those in Ca and control group after the treatment for 12 months (P < 0.001, P < 0.001). The treatment of MESE exercise is the most effective for the improvement of the symptom and indexes in postmenopausal women. Importantly, the low attrition and the high exercise compliance indicate that MESE exercise is safe, feasible, and well tolerated by postmenopausal women. PMID:26107684
Charłusz, Magdalena; Gasztych, Jowita; Irzmański, Robert; Kujawa, Jolanta
2010-01-01
Low back pain syndromes are one of the most frequent causes of movement limitation in populations of highly industrialized countries. They are listed as the main cause of inability to work among people of working age. Chronic pain and the associated limitation of movement underlie the quest for effective therapies. The use of ultrasound, LLLT, vacuum therapy with Ultra Reiz current in physical therapy of these patients prompts research over their effectiveness in the therapy of patients with low-back pain. The aim of the work was to evaluate the analgesic efficacy of LLLT, ultrasound, and vacuum therapy with Ultra Reiz current in patients with low back pain. The study involved 94 people divided into three groups (A,B,C). Group A (n=35) received a series of 10 low energy laser therapy sessions (wave length 808 nm, surface density of radiation 510 mW/cm(2), continuous wave form, scanning mode, a dose of 12 J/cm(2) on a surface of 100 cm(2) [10x10cm]). Patients in Group B (n=27) had ultrasound sessions with a wave intensity of 1 W/cm(2) for 3 minutes. Patients in Group C (n=32) underwent vacuum therapy (8 kPa) combined with Ultra Reiz current. Subjective pain assessment was carried out using a modified Latinen questionnaire and a visual analogue scale of pain intensity. Lumbosacral spine mobility was evaluated with the Schober test and the finger-to- floor test. In Group A, following low energy laser therapy, a statistically significant decrease in pain intensity was observed, together with decreased analgesic consumption compared to the other groups. In Group C, following vacuum therapy combined with Ultra Reiz currents, a significant decrease in the frequency of pain was observed together with increased physical activity compared to both Groups A and B, assessed according to a modified Laitinen pain indicator questionnaire. The biggest improvement in global spine mobility and lumbosacral flexion was observed in Group C (vacuum therapy plus Ultra Reiz current) compared to the other groups. However, the most significant improvement in lower spine extension was noted in Group B (ultrasound). 1. The study showed slightly higher analgesic efficacy of laser biostimulation in comparison to vacuum therapy combined with Ultra Reiz current in patients with low back pain. 2. A more prominent increase in lumbosacral spine mobility was observed after vacuum therapy combined with Ultra Reiz current and ultrasound therapy.
Hocquelet, Arnaud; Cornelis, François; Jirot, Anna; Castaings, Laurent; de Sèze, Mathieu; Hauger, Olivier
2016-10-01
The aim of this study is to compare the accuracy and reliability of spinal curvatures and vertebral rotation data based on patient-specific 3D models created by 3D imaging system or by bi-planar imaging coupled with Moiré-Fringe projections. Sixty-two consecutive patients from a single institution were prospectively included. For each patient, frontal and sagittal calibrated low-dose bi-planar X-rays were performed and coupled simultaneously with an optical Moiré back surface-based technology. The 3D reconstructions of spine and pelvis were performed independently by one radiologist and one technician in radiology using two different semi-automatic methods using 3D radio-imaging system (method 1) or bi-planar imaging coupled with Moiré projections (method 2). Both methods were compared using Bland-Altman analysis, and reliability using intraclass correlation coefficient (ICC). ICC showed good to very good agreement. Between the two techniques, the maximum 95 % prediction limits was -4.9° degrees for the measurements of spinal coronal curves and less than 5° for other parameters. Inter-rater reliability was excellent for all parameters across both methods, except for axial rotation with method 2 for which ICC was fair. Method 1 was faster for reconstruction time than method 2 for both readers (13.4 vs. 20.7 min and 10.6 vs. 13.9 min; p = 0.0001). While a lower accuracy was observed for the evaluation of the axial rotation, bi-planar imaging coupled with Moiré-Fringe projections may be an accurate and reliable tool to perform 3D reconstructions of the spine and pelvis.
Zhao, B; Ding, H; Lu, Y; Wang, G; Zhao, J; Molloi, S
2012-06-01
To investigate the feasibility of an Iterative Reconstruction (IR) method utilizing the algebraic reconstruction technique coupled with dual-dictionary learning for the application of dedicated breast computed tomography (CT) based on a photon-counting detector. Postmortem breast samples were scanned in an experimental fan beam CT system based on a Cadmium-Zinc-Telluride (CZT) photon-counting detector. Images were reconstructed from various numbers of projections with both IR and Filtered-Back-Projection (FBP) methods. Contrast-to-Noise Ratio (CNR) between the glandular and adipose tissue of postmortem breast samples were calculated to evaluate the quality of images reconstructed from IR and FBP. In addition to CNR, the spatial resolution was also used as a metric to evaluate the quality of images reconstructed from the two methods. This is further studied with a high-resolution phantom consisting of a 14 cm diameter, 10 cm length polymethylmethacrylate (PMMA) cylinder. A 5 cm diameter coaxial volume of Interest insert that contains fine Aluminum wires of various diameters was used to determine spatial resolution. The spatial resolution and CNR were better when identical sinograms were reconstructed in IR as compared to FBP. In comparison with FBP reconstruction, a similar CNR was achieved using IR method with up to a factor of 5 fewer projections. The results of this study suggest that IR method can significantly reduce the required number of projections for a CT reconstruction compared to FBP method to achieve an equivalent CNR. Therefore, the scanning time of a CZT-based CT system using the IR method can potentially be reduced. © 2012 American Association of Physicists in Medicine.
The Filtered Abel Transform and Its Application in Combustion Diagnostics
NASA Technical Reports Server (NTRS)
Simons, Stephen N. (Technical Monitor); Yuan, Zeng-Guang
2003-01-01
Many non-intrusive combustion diagnosis methods generate line-of-sight projections of a flame field. To reconstruct the spatial field of the measured properties, these projections need to be deconvoluted. When the spatial field is axisymmetric, commonly used deconvolution method include the Abel transforms, the onion peeling method and the two-dimensional Fourier transform method and its derivatives such as the filtered back projection methods. This paper proposes a new approach for performing the Abel transform method is developed, which possesses the exactness of the Abel transform and the flexibility of incorporating various filters in the reconstruction process. The Abel transform is an exact method and the simplest among these commonly used methods. It is evinced in this paper that all the exact reconstruction methods for axisymmetric distributions must be equivalent to the Abel transform because of its uniqueness and exactness. Detailed proof is presented to show that the two dimensional Fourier methods when applied to axisymmetric cases is identical to the Abel transform. Discrepancies among various reconstruction method stem from the different approximations made to perform numerical calculations. An equation relating the spectrum of a set of projection date to that of the corresponding spatial distribution is obtained, which shows that the spectrum of the projection is equal to the Abel transform of the spectrum of the corresponding spatial distribution. From the equation, if either the projection or the distribution is bandwidth limited, the other is also bandwidth limited, and both have the same bandwidth. If the two are not bandwidth limited, the Abel transform has a bias against low wave number components in most practical cases. This explains why the Abel transform and all exact deconvolution methods are sensitive to high wave number noises. The filtered Abel transform is based on the fact that the Abel transform of filtered projection data is equal to an integral transform of the original projection data with the kernel function being the Abel transform of the filtering function. The kernel function is independent of the projection data and can be obtained separately when the filtering function is selected. Users can select the best filtering function for a particular set of experimental data. When the kernal function is obtained, it can be used repeatedly to a number of projection data sets (rovs) from the same experiment. When an entire flame image that contains a large number of projection lines needs to be processed, the new approach significantly reduces computational effort in comparison with the conventional approach in which each projection data set is deconvoluted separately. Computer codes have been developed to perform the filter Abel transform for an entire flame field. Measured soot volume fraction data of a jet diffusion flame are processed as an example.
Babiolakis, Corinne S; Kuk, Jennifer L; Drake, Janessa D M
2015-01-01
Low back pain is highly prevalent in nurses. This study aimed to determine which physical fitness, physical activity (PA) and biomechanical characteristics most clearly distinguish between nurses with [recently injured (RInj)] and without [not recently injured (NRInj)] a recent back injury. Twenty-seven (8 RInj, 19 NRInj) female nurses completed questionnaires (pain, work, PA), physical fitness, biomechanical and low back discomfort measures, and wore an accelerometer for one work shift. Relative to NRInj nurses, RInj nurses exhibited reduced lumbopelvic control (41.4% more displayed a moderate loss of frontal plane position), less active occupational behaviours (less moderate PA; less patient lifts performed alone; more sitting and less standing time) and more than two times higher low back discomfort scores. Despite no physical fitness differences, the lumbopelvic control, occupational behaviours and discomfort measures differed between nurses with and without recent back injuries. It is unclear whether poor lumbopelvic control is causal or adaptive in RInj nurses and may require further investigation. Practitioner Summary: It is unclear which personal modifiable factors are most clearly associated with low back pain in nurses. Lumbopelvic control was the only performance-based measure to distinguish between nurses with and without recent back injuries. Future research may investigate whether reduced lumbopelvic control is causal or adaptive in recently injured nurses.
Lightweight Seat Lever Operation Characteristics
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar
1999-01-01
In 1999, a Shuttle crew member was unable to operate the backrest lever for the lightweight seat in microgravity. It is essential that crew members can adjust this backrest lever, which is titled forward during launch and then moved backward upon reaching orbit. This adjustment is needed to cushion the crew members during an inadvertent crash landing situation. JSCs Anthropometry and Biomechanics Facility (ABF) performed an evaluation of the seat controls and provided recommendations on whether the seat lever positions and operations should be modified. The original Shuttle seats were replaced with new lightweight seats whose controls were moved, with one control at the front and the other at the back. The ABF designed a 12-person experiment to investigate the amount of pull force exerted by suited subjects, when controls were placed in the front and back of the lightweight seat. Each subject was asked to perform the pull test at least three times for each combination of lever position and suit pressure conditions. The results showed that, in general, the subjects were able to pull on the lever at the back position with only about half the amount of force that they were able to exert on the lever at the front position. In addition, the results also showed that subjects wearing the pressurized suit were unable to reach the seat lever when it was located at the back. The pull forces on the front lever diminished about 50% when subjects wore pressurized suits. Based on these results from this study, it was recommended that the levers should not be located in the back position. Further investigation is needed to determine whether the levers at the front of the seat could be modified or adjusted to increase the leverage for crew members wearing pressurized launch/escape suits.
Training Psychiatry Residents in Quality Improvement: An Integrated, Year-Long Curriculum
ERIC Educational Resources Information Center
Arbuckle, Melissa R.; Weinberg, Michael; Cabaniss, Deborah L.; Kistler; Susan C.; Isaacs, Abby J.; Sederer, Lloyd I.; Essock, Susan M.
2013-01-01
Objective: The authors describe a curriculum for psychiatry residents in Quality Improvement (QI) methodology. Methods: All PGY3 residents (N=12) participated in a QI curriculum that included a year-long group project. Knowledge and attitudes were assessed before and after the curriculum, using a modified Quality Improvement Knowledge Assessment…
Adolescent Career Development in Urban-Residing Aboriginal Families in Canada
ERIC Educational Resources Information Center
Marshall, Sheila K.; Young, Richard A.; Stevens, Alison; Spence, Wayne; Deyell, Stewart; Easterbrook, Adam; Brokenleg, Martin
2011-01-01
The purpose of this study was to understand how urban-residing Aboriginal adolescent-parent dyads (n = 11) jointly constructed and acted on goals and strategies with their social supports (n = 17) to facilitate the adolescents' career development. A modified protocol following the qualitative action-project method was used. A discrete joint…
The Impact of a Service-Learning Design Course on White Students' Racial Attitudes
ERIC Educational Resources Information Center
Houshmand, Sara; Spanierman, Lisa B.; Beer, Amanda M.; Poteat, V. Paul; Lawson, Laura J.
2014-01-01
This study examined the racial attitudes of White undergraduates (N = 15) enrolled in a service-learning design studio, in which students worked closely on landscape architecture projects with residents in a low-income African American community. Using a modified consensual qualitative research method, the authors analyzed a series of guided…
Measurement of whole-body vibration exposure from speed control humps
NASA Astrophysics Data System (ADS)
Khorshid, E.; Alkalby, F.; Kamal, H.
2007-07-01
The main objective of speed control humps is to introduce shocks and high vibration levels when a car passes over them if its speed is higher than the allowable limit. Hump geometry is a major factor in altering the level of these shocks and specifying the speed limit. However, there is no study of the relationship between whole body vibration due to passing over a speed control hump and lower back pain or occupational diseases. In this study, an experimental investigation is conducted to evaluate health risks associated with different geometry speed control humps. Vibration levels and shocks are measured by a seat pad accelerometer placed under the driver's seat to evaluate hazard risks on the human body's lower back. The assessment is based on two standard methods of measuring whole body vibration: the British standard BS 6841 and the new ISO/DIS standard 2631-5. These methods are used to assess the effects of vehicle type, passenger location in the vehicle, vehicle speed, and speed control hump geometry. It was found that circular speed control humps currently installed on many public roads should be modified in order to eliminate hazards. Two newly designed speed humps were proved to be less hazardous than circular speed control humps.
Aerobic Capacity and Cognitive Control in Elementary School-Age Children
Scudder, Mark R.; Lambourne, Kate; Drollette, Eric S.; Herrmann, Stephen; Washburn, Richard; Donnelly, Joseph E.; Hillman, Charles H.
2014-01-01
Purpose The current study examined the relationship between children’s performance on the Progressive Aerobic Cardiovascular Endurance Run (PACER) subtest of the FitnessGram® and aspects of cognitive control that are believed to support academic success. Methods Hierarchical linear regression analyses were conducted on a sample of 2nd and 3rd grade children (n = 397) who completed modified versions of a flanker task and spatial n-back task to assess inhibitory control and working memory, respectively. Results Greater aerobic fitness was significantly related to shorter reaction time and superior accuracy during the flanker task, suggesting better inhibitory control and the facilitation of attention in higher fit children. A similar result was observed for the n-back task such that higher fit children exhibited more accurate target detection and discrimination performance when working memory demands were increased. Conclusion These findings support the positive association between aerobic fitness and multiple aspects of cognitive control in a large sample of children, using a widely implemented and reliable field estimate of aerobic capacity. Importantly, the current results suggest that this relationship is consistent across methods used to assess fitness, which may have important implications for extending this research to more representative samples of children in a variety of experimental contexts. PMID:24743109
Empirical prediction intervals improve energy forecasting
Kaack, Lynn H.; Apt, Jay; Morgan, M. Granger; McSharry, Patrick
2017-01-01
Hundreds of organizations and analysts use energy projections, such as those contained in the US Energy Information Administration (EIA)’s Annual Energy Outlook (AEO), for investment and policy decisions. Retrospective analyses of past AEO projections have shown that observed values can differ from the projection by several hundred percent, and thus a thorough treatment of uncertainty is essential. We evaluate the out-of-sample forecasting performance of several empirical density forecasting methods, using the continuous ranked probability score (CRPS). The analysis confirms that a Gaussian density, estimated on past forecasting errors, gives comparatively accurate uncertainty estimates over a variety of energy quantities in the AEO, in particular outperforming scenario projections provided in the AEO. We report probabilistic uncertainties for 18 core quantities of the AEO 2016 projections. Our work frames how to produce, evaluate, and rank probabilistic forecasts in this setting. We propose a log transformation of forecast errors for price projections and a modified nonparametric empirical density forecasting method. Our findings give guidance on how to evaluate and communicate uncertainty in future energy outlooks. PMID:28760997
Resolution Analysis of finite fault inversions: A back-projection approach.
NASA Astrophysics Data System (ADS)
Ji, C.; Shao, G.
2007-12-01
The resolution of inverted source models of large earthquakes is controlled by frequency contents of "coherent" (or "useful") seismic observations and their spatial distribution. But it is difficult to distinguish whether some features consistent during different inversions are really required by data or a consequence of "prior" information, such as velocity structures, fault geometry, model parameterizations. Here, we investigate the model spatial resolution by first back projecting and stacking the data at the source regions and then analyzing the spatial- temporal variations of the focusing regions, which arbitrarily defined as the regions with 90% of the peak focusing amplitude. Our preliminary results indicated 1) The spatial-temporal resolution at a particularly direction is controlled by the region of directivity parameter [pcos(θ)] within the seismic network, where p is the horizontal slowness from the hypocenter and θ is the difference between the station azimuth and this orientation. Therefore, the network aperture is more important than the number of stations. 2) Simple stacking method is a robust method to capture the asperities but the sizes of focusing regions are usually much larger than what data could resolve. By carefully weighting the data before the stacking could enhance the spatial resolution in a particular direction. 3) The results based on the teleseismic P waves of a local network usually surfers the trade-off between the source's spatial location and its rupture time. The resolution of the 2001 Kunlunshan earthquake and 2006 Kuril island earthquake will be investigated.
Master-slave micromanipulator method
Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.
1999-01-01
A method based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be remotized by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it.
NASA Astrophysics Data System (ADS)
Van de Casteele, Elke; Parizel, Paul; Sijbers, Jan
2012-03-01
Adaptive statistical iterative reconstruction (ASiR) is a new reconstruction algorithm used in the field of medical X-ray imaging. This new reconstruction method combines the idealized system representation, as we know it from the standard Filtered Back Projection (FBP) algorithm, and the strength of iterative reconstruction by including a noise model in the reconstruction scheme. It studies how noise propagates through the reconstruction steps, feeds this model back into the loop and iteratively reduces noise in the reconstructed image without affecting spatial resolution. In this paper the effect of ASiR on the contrast to noise ratio is studied using the low contrast module of the Catphan phantom. The experiments were done on a GE LightSpeed VCT system at different voltages and currents. The results show reduced noise and increased contrast for the ASiR reconstructions compared to the standard FBP method. For the same contrast to noise ratio the images from ASiR can be obtained using 60% less current, leading to a reduction in dose of the same amount.
Topometry of technical and biological objects by fringe projection
NASA Astrophysics Data System (ADS)
Windecker, R.; Tiziani, H. J.
1995-07-01
Fringe projection is a fast and accurate technique for obtaining the topometry of a wide range of surfaces. Here some features of the principle are described, together with the possibilities of adapting this technique for the measurement of vaulted surfaces. We discuss various methods of phase evaluation and compare them with simulated computer data to obtain the resolution limits. Under certain restrictions a semispatial algorithm, called the modified Fourier analysis algorithm, gives the best results. One special subject of interest is the application of fringe projection for the measurement of the three-dimensional surface of the cornea. First results of in vivo measurements are presented.
Cantrell, Jennifer; Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R
2015-01-01
In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined workflow and user-friendly interfaces for data collection; (3) allowing for ongoing communication, feedback, and technology-related skill-building among all staff; and (4) supporting infrastructure for back-end data systems. Although mobile technologies are evolving rapidly, lessons learned from these case studies are essential for ensuring that the many benefits of new mobile systems for rapid point-of-sale surveillance are fully realized.
26 CFR 54.4980H-3 - Determining full-time employees.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-back measurement method, set forth in paragraph (d) of this section. The monthly measurement method... (except with respect to the weekly rule under the monthly measurement method). The look-back measurement... those employees are not full-time employees under the look-back measurement method or the monthly...
Transparent Conductive Ink for Additive Manufacturing
NASA Technical Reports Server (NTRS)
Patlan, X. J.; Rolin, T. D.
2017-01-01
NASA analyzes, tests, packages, and fabricates electrical, electronic, and electromechanical (EEE) parts. Nanotechnology is listed in NASA's Technology Roadmap as a key area to invest for further development.1 This research project focused on using nanotechnology to improve electroluminescent lighting in terms of additive manufacturing and to increase energy efficiency. Specifically, this project's goal was to produce a conductive but transparent printable ink that can be sprayed on any surface for use as one of the electrodes in electroluminescent device design. This innovative work is known as thick film dielectric electroluminescent (TDEL) technology. TDEL devices are used for "backlighting, illumination, and identification due to their tunable color output, scalability, and efficiency" (I.K. Small, T.D. Rolin, and A.D. Shields, "3D Printed Electroluminescent Light Panels," NASA Fiscal Year 2017 Center Innovation Fund Proposal, unpublished data, 2017). These devices use a 'front-to-back' printing method, where the substrate is the transparent layer, and the dielectric and phosphor are layered on top. This project is a first step in the process of creating a 3D printable 'back-to-front' electroluminescent device. Back-to-front 3D-printed devices are beneficial because they can be printed onto different substrates and embedded in different surfaces, and the substrate is not required to be transparent, all because the light is emitted from the top surface through the transparent conductor. Advances in this area will help further development of printing TDEL devices on an array of different surfaces. Figure 1 demonstrates the layering of the two electrodes that are aligned in a parallel plate capacitor structure (I.K. Small, T.D. Rolin, and A.D. Shields, "3D Printed Electroluminescent Light Panels," NASA Fiscal Year 2017 Center Innovation Fund Proposal, unpublished data, 2017). Voltage is applied across the device, and the subsequent electron excitation results in light emission at the top layer.
Effectiveness of Iyengar yoga in treating spinal (back and neck) pain: A systematic review
Crow, Edith Meszaros; Jeannot, Emilien; Trewhela, Alison
2015-01-01
Considerable amount of money spent in health care is used for treatments of lifestyle related, chronic health conditions, which come from behaviors that contribute to morbidity and mortality of the population. Back and neck pain are two of the most common musculoskeletal problems in modern society that have significant cost in health care. Yoga, as a branch of complementary alternative medicine, has emerged and is showing to be an effective treatment against nonspecific spinal pain. Recent studies have shown positive outcome of yoga in general on reducing pain and functional disability of the spine. The objective of this study is to conduct a systematic review of the existing research within Iyengar yoga method and its effectiveness on relieving back and neck pain (defined as spinal pain). Database research form the following sources (Cochrane library, NCBI PubMed, the Clinical Trial Registry of the Indian Council of Medical Research, Google Scholar, EMBASE, CINAHL, and PsychINFO) demonstrated inclusion and exclusion criteria that selected only Iyengar yoga interventions, which in turn, identified six randomized control trials dedicated to compare the effectiveness of yoga for back and neck pain versus other care. The difference between the groups on the postintervention pain or functional disability intensity assessment was, in all six studies, favoring the yoga group, which projected a decrease in back and neck pain. Overall six studies with 570 patients showed, that Iyengar yoga is an effective means for both back and neck pain in comparison to control groups. This systematic review found strong evidence for short-term effectiveness, but little evidence for long-term effectiveness of yoga for chronic spine pain in the patient-centered outcomes. PMID:25558128
Three-Dimensional Passive-Source Reverse-Time Migration of Converted Waves: The Method
NASA Astrophysics Data System (ADS)
Li, Jiahang; Shen, Yang; Zhang, Wei
2018-02-01
At seismic discontinuities in the crust and mantle, part of the compressional wave energy converts to shear wave, and vice versa. These converted waves have been widely used in receiver function (RF) studies to image discontinuity structures in the Earth. While generally successful, the conventional RF method has its limitations and is suited mostly to flat or gently dipping structures. Among the efforts to overcome the limitations of the conventional RF method is the development of the wave-theory-based, passive-source reverse-time migration (PS-RTM) for imaging complex seismic discontinuities and scatters. To date, PS-RTM has been implemented only in 2D in the Cartesian coordinate for local problems and thus has limited applicability. In this paper, we introduce a 3D PS-RTM approach in the spherical coordinate, which is better suited for regional and global problems. New computational procedures are developed to reduce artifacts and enhance migrated images, including back-propagating the main arrival and the coda containing the converted waves separately, using a modified Helmholtz decomposition operator to separate the P and S modes in the back-propagated wavefields, and applying an imaging condition that maintains a consistent polarity for a given velocity contrast. Our new approach allows us to use migration velocity models with realistic velocity discontinuities, improving accuracy of the migrated images. We present several synthetic experiments to demonstrate the method, using regional and teleseismic sources. The results show that both regional and teleseismic sources can illuminate complex structures and this method is well suited for imaging dipping interfaces and sharp lateral changes in discontinuity structures.
Worswick, Louise; Little, Christine; Ryan, Kath; Carr, Eloise
2015-01-01
Research about service user involvement in research and education focuses on the purpose, the methods, the barriers and the impact of their involvement. Few studies report on the experience of the service users who get involved. This paper reports an exploration of the experience of service users who participated in an interprofessional educational initiative in primary care - the Learning to Improve the Management of Back Pain in the Community (LIMBIC) project. Service users attended workshops with practice teams and assisted them in developing small scale quality improvement projects to improve their provision of care for people with back pain. To explore the experience of service users involved in the LIMBIC project. Using the philosophical and methodological approaches of pragmatism this study analysed data from the wider LIMBIC project and collected primary data through semi structured interviews with service users. Secondary data were reanalysed and integrated with primary data to address the research question. The study was undertaken in the primary health care setting. Patients participated as service users in workshops and quality improvement projects with members from their practice teams. Interviews with service users were transcribed and analysed thematically. Document and thematic analyses of secondary data from the LIMBIC project included focus group transcripts, patient stories, film, emails, meeting notes, a wiki and educational material such as presentations. Themes identified through the analyses illustrated the importance, to the service users, of the sense of community, of clear communication, and of influencing change through involvement. A model for co-learning with service users resulted from the analyses. The experience of service users can be optimised by planning, preparation and support so that their wealth of expertise can be recognised and utilised. A model for co-learning was developed and is presented in this paper. Copyright © 2014 Elsevier Ltd. All rights reserved.
Big physics quartet win government backing
NASA Astrophysics Data System (ADS)
Banks, Michael
2014-09-01
Four major physics-based projects are among 10 to have been selected by Japan’s Ministry of Education, Culture, Sports, Science and Technology for funding in the coming decade as part of its “roadmap” of big-science projects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chen, J
Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due tomore » the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.« less
Treatment-Based Classification versus Usual Care for Management of Low Back Pain
2017-10-01
AWARD NUMBER: W81XWH-11-1-0657 TITLE: Treatment-Based Classification versus Usual Care for Management of Low Back Pain PRINCIPAL INVESTIGATOR...Treatment-Based Classification versus Usual Care for Management of Low Back Pain 5b. GRANT NUMBER W81XWH-11-1-0657 5c. PROGRAM ELEMENT NUMBER 6...AUTHOR(S) MAJ Daniel Rhon – daniel_rhon@baylor.edu 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S
2003-04-07
USAWC FELLOWSHIP RESEARCH PROJECT The Army Information Technology Personnel Challenge (Are we selling our seed corn & can we buy it back?) by LTC...YYYY) 07-04-2003 2. REPORT TYPE 3. DATES COVERED (FROM - TO) xx-xx-2002 to xx-xx-2003 4. TITLE AND SUBTITLE The Army Information Technology Personnel...Boggs TITLE: The Army Information Technology Personnel Challenge (Are we selling our seed corn & can we buy it back?) FORMAT: Civilian Fellowship
Polidori, David; Rowley, Clarence
2014-07-22
The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method.
NASA Astrophysics Data System (ADS)
Park, Subok; Zhang, George Z.; Zeng, Rongping; Myers, Kyle J.
2014-03-01
A task-based assessment of image quality1 for digital breast tomosynthesis (DBT) can be done in either the projected or reconstructed data space. As the choice of observer models and feature selection methods can vary depending on the type of task and data statistics, we previously investigated the performance of two channelized- Hotelling observer models in conjunction with 2D Laguerre-Gauss (LG) and two implementations of partial least squares (PLS) channels along with that of the Hotelling observer in binary detection tasks involving DBT projections.2, 3 The difference in these observers lies in how the spatial correlation in DBT angular projections is incorporated in the observer's strategy to perform the given task. In the current work, we extend our method to the reconstructed data space of DBT. We investigate how various model observers including the aforementioned compare for performing the binary detection of a spherical signal embedded in structured breast phantoms with the use of DBT slices reconstructed via filtered back projection. We explore how well the model observers incorporate the spatial correlation between different numbers of reconstructed DBT slices while varying the number of projections. For this, relatively small and large scan angles (24° and 96°) are used for comparison. Our results indicate that 1) given a particular scan angle, the number of projections needed to achieve the best performance for each observer is similar across all observer/channel combinations, i.e., Np = 25 for scan angle 96° and Np = 13 for scan angle 24°, and 2) given these sufficient numbers of projections, the number of slices for each observer to achieve the best performance differs depending on the channel/observer types, which is more pronounced in the narrow scan angle case.
Rattling Cages--Comments on "Hearing Voices" Commentary.
ERIC Educational Resources Information Center
Hall, Ruth L.
1999-01-01
The exploration of the uses of research by G. Russell and J. Bohan illustrates applied feminist research in the use of research results to give something back to the community. Their projects also show that it is possible to be creative in the way in which researchers do give something back to the community. (SLD)
Steffens, Daniel; Hancock, Mark J; Pereira, Leani S M; Kent, Peter M; Latimer, Jane; Maher, Chris G
2016-04-01
Magnetic resonance imaging (MRI) can reveal a range of degenerative findings and anatomical abnormalities; however, the clinical importance of these remains uncertain and controversial. We aimed to investigate if the presence of MRI findings identifies patients with low back pain (LBP) or sciatica who respond better to particular interventions. MEDLINE, EMBASE and CENTRAL databases were searched. We included RCTs investigating MRI findings as treatment effect modifiers for patients with LBP or sciatica. We excluded studies with specific diseases as the cause of LBP. Risk of bias was assessed using the criteria of the Cochrane Back Review Group. Each MRI finding was examined for its individual capacity for effect modification. Eight published trials met the inclusion criteria. The methodological quality of trials was inconsistent. Substantial variability in MRI findings, treatments and outcomes across the eight trials prevented pooling of data. Patients with Modic type 1 when compared with patients with Modic type 2 had greater improvements in function when treated by Diprospan (steroid) injection, compared with saline. Patients with central disc herniation when compared with patients without central disc herniation had greater improvements in pain when treated by surgery, compared with rehabilitation. Although individual trials suggested that some MRI findings might be effect modifiers for specific interventions, none of these interactions were investigated in more than a single trial. High quality, adequately powered trials investigating MRI findings as effect modifiers are essential to determine the clinical importance of MRI findings in LBP and sciatica ( CRD42013006571).
Safakish, Ramin
2017-01-01
Lower back pain (LBP) is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI) joint pain is responsible for LBP in 18%-30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques.
Geometric correction method for 3d in-line X-ray phase contrast image reconstruction
2014-01-01
Background Mechanical system with imperfect or misalignment of X-ray phase contrast imaging (XPCI) components causes projection data misplaced, and thus result in the reconstructed slice images of computed tomography (CT) blurred or with edge artifacts. So the features of biological microstructures to be investigated are destroyed unexpectedly, and the spatial resolution of XPCI image is decreased. It makes data correction an essential pre-processing step for CT reconstruction of XPCI. Methods To remove unexpected blurs and edge artifacts, a mathematics model for in-line XPCI is built by considering primary geometric parameters which include a rotation angle and a shift variant in this paper. Optimal geometric parameters are achieved by finding the solution of a maximization problem. And an iterative approach is employed to solve the maximization problem by using a two-step scheme which includes performing a composite geometric transformation and then following a linear regression process. After applying the geometric transformation with optimal parameters to projection data, standard filtered back-projection algorithm is used to reconstruct CT slice images. Results Numerical experiments were carried out on both synthetic and real in-line XPCI datasets. Experimental results demonstrate that the proposed method improves CT image quality by removing both blurring and edge artifacts at the same time compared to existing correction methods. Conclusions The method proposed in this paper provides an effective projection data correction scheme and significantly improves the image quality by removing both blurring and edge artifacts at the same time for in-line XPCI. It is easy to implement and can also be extended to other XPCI techniques. PMID:25069768
Planning and leading of the technological processes by mechanical working with microsoft project
NASA Astrophysics Data System (ADS)
Nae, I.; Grigore, N.
2016-08-01
Nowadays, fabrication systems and methods are being modified; new processing technologies come up, flow sheets develop a minimum number of phases, the flexibility of the technologies grows up, new methods and instruments of monitoring and leading the processing operations also come up. The technological course (route, entry, scheme, guiding) referring to the series of the operation, putting and execution phases of a mark in order to obtain the final product from the blank is represented by a sequence of activities realized by a logic manner, on a well determined schedule, with a determined budget and resources. Also, a project can be defined as a series of specific activities, methodical structured which they aim to finish a specific objective, within a fixed schedule and budget. Within the homogeneity between the project and the technological course, this research is presenting the defining of the technological course of mechanical chip removing process using Microsoft Project. Under these circumstances, this research highlights the advantages of this method: the celerity using of other technological alternatives in order to pick the optimal process, the job scheduling being constrained by any kinds, the standardization of some processing technological operations.
Ventilation mapping of chest using Focused Impedance Method (FIM)
NASA Astrophysics Data System (ADS)
Kadir, M. Abdul; Ferdous, Humayra; Baig, Tanvir Noor; Siddique-e-Rabbani, K.
2010-04-01
Focused Impedance Method (FIM) provides an opportunity for localized impedance measurement down to reasonable depths within the body using surface electrodes, and has a potential application in localized lung ventilation study. This however needs assessment of normal values for healthy individuals. In this study, localized ventilation maps in terms of electrical impedance in a matrix formation around the thorax, both from the front and the back, were obtained from two normal male subjects using a modified configuration of FIM. For this the focused impedance values at full inspiration and full expiration were measured and the percentage difference with respect to the latter was used. Some of the measured values would have artefacts due to movements of the heart and the diaphragm in the relevant anatomical positions which needs to be considered with due care in any interpretation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dall-Anese, Emiliano; Bernstein, Andrey; Simonetto, Andrea
This paper develops an online optimization method to maximize operational objectives of distribution-level distributed energy resources (DERs), while adjusting the aggregate power generated (or consumed) in response to services requested by grid operators. The design of the online algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements from the distribution network and the DERs. By virtue of this approach, the resultant algorithm can cope with inaccuracies in the representation of the AC power flows, it avoids pervasive metering to gather the state of noncontrollable resources, and it naturally lends itself to a distributed implementation. Optimality claimsmore » are established in terms of tracking of the solution of a well-posed time-varying convex optimization problem.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dall-Anese, Emiliano; Bernstein, Andrey; Simonetto, Andrea
This paper develops an online optimization method to maximize the operational objectives of distribution-level distributed energy resources (DERs) while adjusting the aggregate power generated (or consumed) in response to services requested by grid operators. The design of the online algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements from the distribution network and the DERs. By virtue of this approach, the resultant algorithm can cope with inaccuracies in the representation of the AC power, it avoids pervasive metering to gather the state of noncontrollable resources, and it naturally lends itself to a distributed implementation. Optimality claimsmore » are established in terms of tracking of the solution of a well-posed time-varying optimization problem.« less
ERIC Educational Resources Information Center
Brevard Community Coll., Cocoa, FL.
This manual describes and evaluates the implementation of Project BEST-PAL (Basic Education Skills Through-Parent Affective Learning), Brevard Community College's special demonstration training project intended to return adults who have dropped out of the educational system back into the learning environment by bringing them to parenting classes…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altunbas, Cem, E-mail: caltunbas@gmail.com; Lai, Chao-Jen; Zhong, Yuncheng
Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrancemore » exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.« less
van Zadelhoff, Claudia; Ehrle, Anna; Merle, Roswitha; Jahn, Werner; Lischer, Christoph
2018-05-09
Scintigraphy is a standard diagnostic method for evaluating horses with back pain due to suspected thoracic processus spinosus pathology. Lesion detection is based on subjective or semi-quantitative assessments of increased uptake. This retrospective, analytical study is aimed to compare semi-quantitative and subjective methods in the evaluation of scintigraphic images of the processi spinosi in the equine thoracic spine. Scintigraphic images of 20 Warmblood horses, presented for assessment of orthopedic conditions between 2014 and 2016, were included in the study. Randomized, blinded image evaluation was performed by 11 veterinarians using subjective and semi-quantitative methods. Subjective grading was performed for the analysis of red-green-blue and grayscale scintigraphic images, which were presented in full-size or as masked images. For the semi-quantitative assessment, observers placed regions of interest over each processus spinosus. The uptake ratio of each processus spinosus in comparison to a reference region of interest was determined. Subsequently, a modified semi-quantitative calculation was developed whereby only the highest counts-per-pixel for a specified number of pixels was processed. Inter- and intraobserver agreement was calculated using intraclass correlation coefficients. Inter- and intraobserver intraclass correlation coefficients were 41.65% and 71.39%, respectively, for the subjective image assessment. Additionally, a correlation between intraobserver agreement, experience, and grayscale images was identified. The inter- and intraobserver agreement was significantly increased when using semi-quantitative analysis (97.35% and 98.36%, respectively) or the modified semi-quantitative calculation (98.61% and 98.82%, respectively). The proposed modified semi-quantitative technique showed a higher inter- and intraobserver agreement when compared to other methods, which makes it a useful tool for the analysis of scintigraphic images. The association of the findings from this study with clinical and radiological examinations requires further investigation. © 2018 American College of Veterinary Radiology.
NASA Astrophysics Data System (ADS)
Kostrzewa, Daniel; Josiński, Henryk
2016-06-01
The expanded Invasive Weed Optimization algorithm (exIWO) is an optimization metaheuristic modelled on the original IWO version inspired by dynamic growth of weeds colony. The authors of the present paper have modified the exIWO algorithm introducing a set of both deterministic and non-deterministic strategies of individuals' selection. The goal of the project was to evaluate the modified exIWO by testing its usefulness for multidimensional numerical functions optimization. The optimized functions: Griewank, Rastrigin, and Rosenbrock are frequently used as benchmarks because of their characteristics.
NASA Technical Reports Server (NTRS)
Blacksberg, Jordana (Inventor); Hoenk, Michael Eugene (Inventor); Nikzad, Shouleh (Inventor)
2010-01-01
A method is provided for growing a back surface contact on an imaging detector used in conjunction with back illumination. In operation, an imaging detector is provided. Additionally, a back surface contact (e.g. a delta-doped layer, etc.) is grown on the imaging detector utilizing a process that is performed at a temperature less than 450 degrees Celsius.
Rupture evolution of the 2006 Java tsunami earthquake and the possible role of splay faults
NASA Astrophysics Data System (ADS)
Fan, Wenyuan; Bassett, Dan; Jiang, Junle; Shearer, Peter M.; Ji, Chen
2017-11-01
The 2006 Mw 7.8 Java earthquake was a tsunami earthquake, exhibiting frequency-dependent seismic radiation along strike. High-frequency global back-projection results suggest two distinct rupture stages. The first stage lasted ∼65 s with a rupture speed of ∼1.2 km/s, while the second stage lasted from ∼65 to 150 s with a rupture speed of ∼2.7 km/s. High-frequency radiators resolved with back-projection during the second stage spatially correlate with splay fault traces mapped from residual free-air gravity anomalies. These splay faults also colocate with a major tsunami source associated with the earthquake inferred from tsunami first-crest back-propagation simulation. These correlations suggest that the splay faults may have been reactivated during the Java earthquake, as has been proposed for other tsunamigenic earthquakes, such as the 1944 Mw 8.1 Tonankai earthquake in the Nankai Trough.
The Project for Developing Countermeasures against Landslides in the Abay River Gorge, Ethiopia
NASA Astrophysics Data System (ADS)
Guta, H. E.
2016-12-01
The Blue Nile Gorge of Ethiopia is characterized by high relief landscape. The stretch of major arterial road that connects Ethiopia to Sudan passes through the Gorge. The Gorge is plagued by swarms of landslides which makes it a tremendous obstacle for travel and communication. Therefore, landside study was carried out from 2010 to 2012 by JICA and Geological survey of Ethiopia to figure out the mechanisms that trigger the swarms of landslides that occur in the area and identify appropriate countermeasures that would be best implemented. The study included geomorphologic and geologic survey, drilling survey, displacement monitoring, ground water and precipitation monitoring, geophysical exploration, and stability analysis. About 42 landslide monitoring instruments namely extensometers (both surface and borehole), inclinometers and ground water level meters were installed in four highly landslide prone areas to detect slip surface, and determine amount and direction of movement. The amount of landslide movement at the four zones is 42.4, 57.6, 294.9 and 136mm during rainy season. Ground water level rising, nature of material and intense rainfall are found to be among the major triggering factors. Stability analysis using Simple Jambu and modified Fellenus methods was conducted resulting in safety factor Fs less than one and reasonably 0.98 by adopting shear parameters of soils by back analysis. By assuming cohesion (c') to be very close to 0 due to landslide blocks active movement when ground water rises during rainy season, Shear resistance angle, ɸ, was obtained to be 10.80, 26.30, 10.20 and 16.30 in the four areas using Modified Fellenius method and 10.70, 26.60, 10.00 and 16.10 using Simple Janbu method. Effect of countermeasures was checked by trial calculation. Accordingly the factory of safety increased from 0.98 to 1.2 when ɸ=60, ground water is lowered by 6m, and steel pipe pile of ɸ500mm x t40mm at an interval of 1.9m are implemented. consequently, buttress fill works and surface drainage works are designed countermeasures in the first stage. Furthermore, improvement of safety factor in the landslides by steep pile works or horizontal drainage borings are suitable countermeasures to be adopted in the second stage. Key words: Blue Nile Gorge, Landslide, Slope stability analysis, Countermeasure works
Prevalence of low back pain among handloom weavers in West Bengal, India.
Durlov, Santu; Chakrabarty, Sabarni; Chatterjee, Arijit; Das, Tamal; Dev, Samrat; Gangopadhyay, Somnath; Haldar, Prasun; Maity, Santi Gopal; Sarkar, Krishnendu; Sahu, Subhashis
2014-10-01
Handloom is one of the oldest industries in India, particularly in West Bengal, where a considerable number of rural people are engaged in weaving. The purpose of this study was to evaluate the prevalence of low back pain among the handloom weavers in India. A modified Nordic Musculoskeletal Disorder Questionnaire and Oswestry Low Back Pain Disability Questionnaire along with a body part discomfort scale were administered to handloom weavers (n = 175). Working posture of the participants was assessed using the Ovako Working Posture Analysis System (OWAS). Sixty eight per cent of the participants reported suffering from low back pain, making it the most prevalent disorder in our sample. Analysis of the Oswestry Low Back Pain Disability Questionnaire data revealed that among those with low back pain (n = 119), 2% had severe disabilities, 46% had moderate disabilities, and 52% had minimal disabilities. Statistical analyses revealed a positive significant association between the intensity of pain in the lower back and an increased number of years of work experience (P<0·05). The study underlines the need for further research regarding the postural strain of weavers and also suggests the implementation of ergonomic design into weaver workstations to minimize the adverse effect of their current working postures. Improving upon the weaver's work-posture could improve their quality of life.
Light ray field capture using focal plane sweeping and its optical reconstruction using 3D displays.
Park, Jae-Hyeung; Lee, Sung-Keun; Jo, Na-Young; Kim, Hee-Jae; Kim, Yong-Soo; Lim, Hong-Gi
2014-10-20
We propose a method to capture light ray field of three-dimensional scene using focal plane sweeping. Multiple images are captured using a usual camera at different focal distances, spanning the three-dimensional scene. The captured images are then back-projected to four-dimensional spatio-angular space to obtain the light ray field. The obtained light ray field can be visualized either using digital processing or optical reconstruction using various three-dimensional display techniques including integral imaging, layered display, and holography.
NASA Astrophysics Data System (ADS)
Wang, Lei; Fan, Youping; Zhang, Dai; Ge, Mengxin; Zou, Xianbin; Li, Jingjiao
2017-09-01
This paper proposes a method to simulate a back-to-back modular multilevel converter (MMC) HVDC transmission system. In this paper we utilize an equivalent networks to simulate the dynamic power system. Moreover, to account for the performance of converter station, core components of model of the converter station gives a basic model of simulation. The proposed method is applied to an equivalent real power system.
Ceramic composite protection for turbine disc bursts. [for the A-300 aircraft
NASA Technical Reports Server (NTRS)
Gardner, P. B.
1977-01-01
Ceramic composite turbine disc protection panels for the A300B were developed using armor technology. Analytical predictions for modifying the ballistic projectile armor system were verified by a test program conducted to qualify the rotor containment system. With only a slight change in the areal density of the armor system a more than two-fold increase in kinetic energy protection level was achieved. Thickness of the fiberglass reinforced plastic backing material was increased to achieve an optimum ratio of ceramic thickness to backing thickness for the different ballistic defeat condition.
2014-01-01
Background The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. Methods We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Conclusions Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method. PMID:25052018
Precise Aperture-Dependent Motion Compensation with Frequency Domain Fast Back-Projection Algorithm.
Zhang, Man; Wang, Guanyong; Zhang, Lei
2017-10-26
Precise azimuth-variant motion compensation (MOCO) is an essential and difficult task for high-resolution synthetic aperture radar (SAR) imagery. In conventional post-filtering approaches, residual azimuth-variant motion errors are generally compensated through a set of spatial post-filters, where the coarse-focused image is segmented into overlapped blocks concerning the azimuth-dependent residual errors. However, image domain post-filtering approaches, such as precise topography- and aperture-dependent motion compensation algorithm (PTA), have difficulty of robustness in declining, when strong motion errors are involved in the coarse-focused image. In this case, in order to capture the complete motion blurring function within each image block, both the block size and the overlapped part need necessary extension leading to degeneration of efficiency and robustness inevitably. Herein, a frequency domain fast back-projection algorithm (FDFBPA) is introduced to deal with strong azimuth-variant motion errors. FDFBPA disposes of the azimuth-variant motion errors based on a precise azimuth spectrum expression in the azimuth wavenumber domain. First, a wavenumber domain sub-aperture processing strategy is introduced to accelerate computation. After that, the azimuth wavenumber spectrum is partitioned into a set of wavenumber blocks, and each block is formed into a sub-aperture coarse resolution image via the back-projection integral. Then, the sub-aperture images are straightforwardly fused together in azimuth wavenumber domain to obtain a full resolution image. Moreover, chirp-Z transform (CZT) is also introduced to implement the sub-aperture back-projection integral, increasing the efficiency of the algorithm. By disusing the image domain post-filtering strategy, robustness of the proposed algorithm is improved. Both simulation and real-measured data experiments demonstrate the effectiveness and superiority of the proposal.
ANALYSIS OF OUT OF DATE MCU MODIFIER LOCATED IN SRNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C.
2014-10-22
SRNL recently completed density measurements and chemical analyses on modifier samples stored in drums within SRNL. The modifier samples date back to 2008 and are in various quantities up to 40 gallons. Vendor information on the original samples indicates a shelf life of 5 years. There is interest in determining if samples that have been stored for more than the 5 year shelf life are still acceptable for use. The Modular Caustic Side Solvent Extraction Unit (MCU) Solvent component Cs-7SB [(2,2,3,3- tetraflouropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, CAS #308362-88-1] is used as a diluent modifier to increase extractant solubility and provide physical characteristics necessary formore » diluent trimming.« less
Pilot Study for the Active TV Viewer Scholar Education. Final Report. Years 1984-1985.
ERIC Educational Resources Information Center
Torres, Miguel Reyes
The purposes of the "Pilot Study for the Active TV Viewer Scholar Education" project were to find low cost teaching methods that developed critical television viewing skills among elementary and secondary students, and to develop a parallel program of family education in an effort to modify family viewing practices to encourage critical…
IRIS DMC products help explore the Tohoku earthquake
NASA Astrophysics Data System (ADS)
Trabant, C.; Hutko, A. R.; Bahavar, M.; Ahern, T. K.; Benson, R. B.; Casey, R.
2011-12-01
Within two hours after the great March 11, 2011 Tohoku earthquake the IRIS DMC started publishing automated data products through its Searchable Product Depository (SPUD), which provides quick viewing of many aspects of the data and preliminary analysis of this great earthquake. These products are part of the DMC's data product development effort intended to serve many purposes: stepping-stones for future research projects, data visualizations, data characterization, research result comparisons as well as outreach material. Our current and soon-to-be-released products that allow users to explore this and other global M>6.0 events include 1) Event Plots, which are a suite of maps, record sections, regional vespagrams and P-coda stacks 2) US Array Ground Motion Visualizations that show the vertical and horizontal global seismic wavefield sweeping across US Array including minor and major arc surface waves and their polarizations 3) back-projection movies that show the time history of short-period energy from the rupture 4) R1 source-time functions that show approximate duration and source directivity and 5) aftershock sequence maps and statistics movies based on NEIC alerts that self-update every hour in the first few days following the mainshock. Higher order information for the Tohoku event that can be inferred based on our products which will be highlighted include a rupture duration of order 150 sec (P-coda stacks, back-projections, R1 STFs) that ruptured approximately 400 km along strike primarily towards the south (back-projections, R1 STFs, aftershock animation) with a very low rupture velocity (back-projections, R1 STFs). All of our event-based products are automated and consistently produced shortly after the event so that they may serve as familiar baselines for the seismology research community. More details on these and other existing products are available at: http://www.iris.edu/dms/products/
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2013 CFR
2013-10-01
... (30 psig), if fired with solid fuel not in suspension, or if not equipped for unattended waterbed... back Scotch boilers, 2 inches above the top row of tubes. (j) [Reserved] (k)(1) Fusible plugs shall be...
NASA Technical Reports Server (NTRS)
Swaim, Benji D.
1989-01-01
Modified orifice for variable-polarity plasma-arc welding directs welding plume so it creates clean, even welds on both Inconel(R) and aluminum alloys. Includes eight holes to relieve back pressure in plasma. Quality of welds on ferrous and nonferrous alloys improved as result.
Dougherty, T B; Porche, V H; Thall, P F
2000-04-01
This study investigated the ability of the modified continual reassessment method (MCRM) to determine the maximum tolerated dose of the opioid antagonist nalmefene, which does not reverse analgesia in an acceptable number of postoperative patients receiving epidural fentanyl in 0.075% bupivacaine. In the postanesthetic care unit, patients received a single intravenous dose of 0.25, 0.50, 0.75, or 1.00 microg/kg nalmefene. Reversal of analgesia was defined as an increase in pain score of two or more integers above baseline on a visual analog scale from 0 through 10 after nalmefene administration. Patients were treated in cohorts of one, starting with the lowest dose. The maximum tolerated dose of nalmefene was defined as that dose, among the four studied, with a final mean probability of reversal of anesthesia (PROA) closest to 0.20 (ie., a 20% chance of causing reversal). The modified continual reassessment method is an iterative Bayesian statistical procedure that, in this study, selected the dose for each successive cohort as that having a mean PROA closest to the preselected target PROA of 0.20. The modified continual reassessment method repeatedly updated the PROA of each dose level as successive patients were observed for presence or absence of ROA. After 25 patients, the maximum tolerated dose of nalmefene was selected as 0.50 microg/kg (final mean PROA = 0.18). The 1.00-microg/kg dose was never tried because its projected PROA was far above 0.20. The modified continual reassessment method facilitated determination of the maximum tolerated dose ofnalmefene . Operating characteristics of the modified continual reassessment method suggest it may be an effective statistical tool for dose-finding in trials of selected analgesic or anesthetic agents.
Understanding the Up, Back, and Forward-Component in Master's Thesis Supervision with Adaptivity
ERIC Educational Resources Information Center
de Kleijn, Renske A. M.; Bronkhorst, Larike H.; Meijer, Paulien C.; Pilot, Albert; Brekelmans, Mieke
2016-01-01
Despite the importance of goals in educational theories, goals in master's thesis projects are rarely investigated. Therefore, this study explores how goals play a role in master's thesis supervision in terms of: defining the goals (up-component); locating where the student stands in relation to the goals (back-component); and how the student can…
35. From Final Construction Report on the Haleakala Road ProjectNR7, ...
35. From Final Construction Report on the Haleakala Road Project--NR-7, Hawaii National Park, Island of Maui, Territory of Hawaii. LOOKING BACK FROM STATION 335 AT RETURN CURVE. - Haleakala National Park Roads, Pukalani, Maui County, HI
KazRAM: Build Your Own Raman Spectrometer for Environmental Science Education in Kazakhstan
NASA Astrophysics Data System (ADS)
Redfern, S. A. T.; Seitkan, A.
2016-12-01
The development of field-based spectroscopic investigations in Eastern Kazakhstan has been held-back by the lack of access to spectroscopic methods and technologies. This has been addressed in this project, in which we use a modular system of construction to allow a Raman spectrometer to be built in the University classroom. In collaboration with scientists at East Kazakhstan State University the team at Cambridge University have designed and developed an instrument that can be replicated in the near-field environment in Central Asia. This allows students to gain a first-hand understanding of the principles and practise of Raman spectroscopy by constructing their own instrument. The project will then allow measurement of key samples in both biological ecology settings as well as in geological and mining exploration contexts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, Bill; Smith, Benjamin
Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/- 4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis showsmore » the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.« less
NASA Astrophysics Data System (ADS)
Li, Bin; Wang, Dayong; Rong, Lu; Zhai, Changchao; Wang, Yunxin; Zhao, Jie
2018-02-01
Terahertz (THz) radiation is able to penetrate many different types of nonpolar and nonmetallic materials without the damaging effects of x-rays. THz technology can be combined with computed tomography (CT) to form THz CT, which is an effective imaging method that is used to visualize the internal structure of a three-dimensional sample as cross-sectional images. Here, we reported an application of THz as the radiation source in CT imaging by replacing the x-rays. In this method, the sample cross section is scanned in all translation and rotation directions. Then, the projection data are reconstructed using a tomographic reconstruction algorithm. Two-dimensional (2-D) cross-sectional images of the chicken ulna were obtained through the continuous-wave (CW) THz CT system. Given by the difference of the THz absorption of different substances, the compact bone and spongy bone inside the chicken ulna are structurally distinguishable in the 2-D cross-sectional images. Using the filtered back projection algorithm, we reconstructed the projection data of the chicken ulna at different projection angle intervals and found that the artifacts and noise in the images are strikingly increased when the projection angle intervals become larger, reflected by the blurred boundary of the compact bone. The quality and fidelity of the 2-D cross-sectional images could be substantially improved by reducing the projection angle intervals. Our experimental data demonstrated a feasible application of the CW THz CT system in biological imaging.
[Sacroiliac joint dysfunction presented with acute low back pain: three case reports].
Hamauchi, Shuji; Morimoto, Daijiro; Isu, Toyohiko; Sugawara, Atsushi; Kim, Kyongsong; Shimoda, Yusuke; Motegi, Hiroaki; Matsumoto, Ryoji; Isobe, Masanori
2010-07-01
Sacroiliac joint (SIJ) can cause low back pain when its joint capsule and ligamentous tissue are damaged. We report our experience in treating three SIJ dysfunction patients presenting with acute low back pain (a 38 year-old male, a 24 year-old male, and a 32 year-old female). SIJ dysfunction was diagnosed using the one-finger test, the modified Newton test, and SIJ injection. In all three patients, lumbar MRI demonstrated slightly degenerated lumbar lesions (lumbar canal stenosis, lumbar disc hernia). Two patients had paresthesia or pain in the leg and all three patients showed iliac muscle tenderness in the groin, which was thought to be a referred symptom because of improvement after SIJ injection. The two male patients returned to work and the problems have not recurred. Although our female patient resumed daily life as a housewife, her condition recurred at intervals of 2-3 months and she required regular SIJ injections. The prevalence of SIJ dysfunction of low back pain is about 10%, so it should be considered as a differential diagnosis when treating low back pain and designing treatment for lumbar spinal disorders.
Feed-back modulation of cone synapses by L-horizontal cells of turtle retina.
Gerschenfeld, H M; Piccolino, M; Neyton, J
1980-12-01
Light stimulation of the periphery of the receptive field of turtle cones can evoke both transient and sustained increases of the cone Ca2+ conductance, which may become regenerative. Such increase in the cone Ca2+ conductance evoked by peripheral illumination results from the activation of a polysynaptic pathway involving a feed-back connexion from the L-horizontal cells (L-HC) to the cones. Thus the hyperpolarization of a L-HC by inward current injection can evoke a Ca2+ conductance increase in neighbouring cones. The cone Ca2+ channels thus activated are likely located at its synaptic endings and probably intervene in the cone transmitter release. Therefore the feed-back connexion between L-HC and cones by modifying the Ca2+ conductance of cones could actually modulate the transmitter release from cone synapses. Such feed-back modulation of cone synapses plays a role in the organization of the colour-coded responses of the chromaticity type-horizontal cells and probably of other second order neurones, post-synaptic to the cones. The mechanisms operating the feed-back connexion from L-HC to cones are discussed.
Geometry-constraint-scan imaging for in-line phase contrast micro-CT.
Fu, Jian; Yu, Guangyuan; Fan, Dekai
2014-01-01
X-ray phase contrast computed tomography (CT) uses the phase shift that x-rays undergo when passing through matter, rather than their attenuation, as the imaging signal and may provide better image quality in soft-tissue and biomedical materials with low atomic number. Here a geometry-constraint-scan imaging technique for in-line phase contrast micro-CT is reported. It consists of two circular-trajectory scans with x-ray detector at different positions, the phase projection extraction method with the Fresnel free-propagation theory and the filter back-projection reconstruction algorithm. This method removes the contact-detector scan and the pure phase object assumption in classical in-line phase contrast Micro-CT. Consequently it relaxes the experimental conditions and improves the image contrast. This work comprises a numerical study of this technique and its experimental verification using a biomedical composite dataset measured at an x-ray tube source Micro-CT setup. The numerical and experimental results demonstrate the validity of the presented method. It will be of interest for a wide range of in-line phase contrast Micro-CT applications in biology and medicine.
Evaluation of field projects using crumb rubber modified asphaltic concrete.
DOT National Transportation Integrated Search
2007-03-01
In 1994, the Louisiana Department of Transportation and Development (LADOTD) initiated a research project to evaluate different crumb-rubber modified (CRM) applications in which the long-term pavement performance of the CRM asphalt pavements was comp...
Evaluation of Work-Related Musculoskeletal Disorders and Postural Stress of Female "Jari" Workers.
Pal, Amitava; Dhara, Prakash C
2017-01-01
The present investigation was aimed to assess the postural stress and the prevalence of musculoskeletal disorders (MSDs) of the "Jari" (golden thread) workers. This cross-sectional study was carried out on 156 female workers in different areas of the Purba Medinipur, Paschim Medinipur, and Howrah districts of West Bengal, India. The MSDs of the workers were evaluated by modified Nordic questionnaire method. The postural pattern during work was assessed by direct observation method. The posture of Jari workers has been analyzed by OWAS, REBA, and RULA methods. The joint angle in normal and working posture was observed. The prevalence of MSDs was very high among the workers. The major locations of body pains in Jari workers were lower back, upper back, neck, wrist, thigh, and shoulder. The occurrence of MSDs was higher in lower and higher age group than that of the middle age group. The total work shift of the workers was approximately 13 h including rest pause. The dominant postures adopted by the workers were sitting on the floor with stretched legs, sitting on the floor with folded knees, and kneeling posture. From the results of the postural analysis, the postures of the Jari workers had been categorized as stressful. There were a significant deviation between normal standing angles and working angles. From the overall study, it may be concluded that adoption of stressful postures for longer duration might be the cause of MSDs in different body parts of the Jari workers.
Improved Measurement of Dispersion in an Optical Fiber
NASA Technical Reports Server (NTRS)
Huang, Shouhua; Le, Thanh; Maleki, Lute
2004-01-01
An improved method of measuring chromatic dispersion in an optical fiber or other device affords a lower (relative to prior such methods) limit of measurable dispersion. This method is a modified version of the amplitude-modulation (AM) method, which is one of the prior methods. In comparison with the other prior methods, the AM method is less complex. However, the AM method is limited to dispersion levels . 160 ps/nm and cannot be used to measure the symbol of the dispersion. In contrast, the present modified version of the AM method can be used to measure the symbol of the symbol of the dispersion and affords a measurement range from about 2 ps/nm to several thousand ps/nm with a resolution of 0.27 ps/nm or finer. The figure schematically depicts the measurement apparatus. The source of light for the measurement is a laser, the wavelength of which is monitored by an optical spectrum analyzer. A light-component analyzer amplitude-modulates the light with a scanning radio-frequency signal. The modulated light is passed through a buffer (described below) and through the device under test (e.g., an optical fiber, the dispersion of which one seeks to measure), then back to the light-component analyzer for spectrum analysis. Dispersion in the device under test gives rise to phase shifts among the carrier and the upper and lower sideband components of the modulated signal. These phase shifts affect the modulation-frequency component of the output of a photodetector exposed to the signal that emerges from the device under test. One of the effects is that this component goes to zero periodically as the modulation frequency is varied.
Evaluation of Work-Related Musculoskeletal Disorders and Postural Stress of Female “Jari” Workers
Pal, Amitava; Dhara, Prakash C.
2017-01-01
Aims: The present investigation was aimed to assess the postural stress and the prevalence of musculoskeletal disorders (MSDs) of the “Jari” (golden thread) workers. Settings and Design: This cross-sectional study was carried out on 156 female workers in different areas of the Purba Medinipur, Paschim Medinipur, and Howrah districts of West Bengal, India. Materials and Methods: The MSDs of the workers were evaluated by modified Nordic questionnaire method. The postural pattern during work was assessed by direct observation method. The posture of Jari workers has been analyzed by OWAS, REBA, and RULA methods. The joint angle in normal and working posture was observed. Results and Conclusions: The prevalence of MSDs was very high among the workers. The major locations of body pains in Jari workers were lower back, upper back, neck, wrist, thigh, and shoulder. The occurrence of MSDs was higher in lower and higher age group than that of the middle age group. The total work shift of the workers was approximately 13 h including rest pause. The dominant postures adopted by the workers were sitting on the floor with stretched legs, sitting on the floor with folded knees, and kneeling posture. From the results of the postural analysis, the postures of the Jari workers had been categorized as stressful. There were a significant deviation between normal standing angles and working angles. From the overall study, it may be concluded that adoption of stressful postures for longer duration might be the cause of MSDs in different body parts of the Jari workers. PMID:29618913
Miranda, Iã Ferreira; Souza, Catiane; Schneider, Alexandre Tavares; Chagas, Leandro Campos; Loss, Jefferson Fagundes
2018-05-01
There is some evidence in the literature about the effectiveness of the Pilates methods in the low back pain. Moreover, Pilates focus on exercises that empathizes the stability and/or mobility of the spine. Therefore, it is discussed in the literature whether higher levels of stability or mobility of the lumbar spine generates better results, both in performance and rehabilitation for low back pain. Compare the effects of the low back mobility and stability exercises from Pilates Method on low back pain, disability and movement functionality in individuals with non-specific chronic low back pain. 28 participants will be randomized into two exercise protocol from Pilates methods, one focusing on low back stability and other on low back mobility. Low back pain (visual analogic scale), low back disability (Oswestry) and movement functionality (7 functional movement tasks) will be evaluated before and after 10 sessions of Pilates exercise by the same trained assessor. A mixed designed ANOVA with two factors will be used. This study is the first to compare these outcomes for chronic low back pain participants with two exercises protocol focusing on low back mobility and stability and the results will evaluate what to prioritize with Pilates exercises to give better results for that population. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Matsubara, Makoto; Sato, Hiroshi; Ishiyama, Tatsuya; Van Horne, Anne
2017-07-01
The Mohorovičić discontinuity (Moho) is defined on the basis of an abrupt increase in seismic velocity in the lithosphere which has been observed using seismic refraction and receiver function analysis methods worldwide. Moho depth varies regionally and remains a fundamental parameter of crustal structure. We present a new method of mapping the Moho using a 3D seismic tomography model. Since the tomographic method cannot locate discontinuities, we treat the Moho as a zone of high velocity gradient. Maximum lower crust/minimum upper mantle P-wave velocities in Japan are known to be 7.0 km/s and 7.5 km/s, respectively. We map the residual between isovelocity surfaces of 7.0 km/s and 7.5 km/s to find areas where the residual is small, the separation between the surfaces is narrow, and the velocity gradient is high. The Moho is best constrained where the isovelocity surfaces are close together, and under much of Japan, they are < 6 km and rarely > 10 km apart. We chose an isovelocity surface of 7.2 km/s as a representative Moho 'proxy' in these areas. Our resulting 'Moho' map under Japan compares favorably with existing regional Moho models that were obtained from controlled-source seismic investigations. The 'Moho' varies from shallow (25-30 km) to deep (> 30 km), and this variability relates to the structural evolution of the Japanese islands: the opening of the Sea of Japan back-arc, ongoing arc-arc collisions at the Hidaka and Izu collision zones, ongoing back-arc extension in Kyushu, and a possible failed back-arc extensional event of Mesozoic age. It is apparent that the Moho is less well-constrained in areas where the crustal structure has been modified by magmatic activity or thickened due to arc-arc collision.
Boeing 747 jet modified to carry shuttle en route to Dryden
NASA Technical Reports Server (NTRS)
1977-01-01
A Boeing 747 jet aircraft, modified for use by NASA for the Space Shuttle Orbiter Approach and Landing Tests (ALTs), is seen en route from the Boeing facility at Seattle, Washington, to the Dryden Flight Research Center in Southern California. Note the added structural supports atop the huge aircraft. The Shuttle Orbiter will ride 'piggy-back' atop the NASA 747 for the ALTs. The NASA 747 will be used also to transport Orbiters to the Space Shuttle launch sites.
2008-12-09
The Space Shuttle Endeavour and its modified Boeing 747 carrier aircraft are illuminated by the morning sun Tuesday after mating of the pair was completed overnight in the Mate-DeMate gantry at NASA Dryden Flight Research Center. The pair are scheduled to depart Edwards Air Force Base on their ferry flight back to the Kennedy Space Center early Wednesday morning, Dec. 10.
The Reliability and Validity of the Computerized Double Inclinometer in Measuring Lumbar Mobility
MacDermid, Joy Christine; Arumugam, Vanitha; Vincent, Joshua Israel; Carroll, Krista L
2014-01-01
Study Design : Repeated measures reliability/validity study. Objectives : To determine the concurrent validity, test-retest, inter-rater and intra-rater reliability of lumbar flexion and extension measurements using the Tracker M.E. computerized dual inclinometer (CDI) in comparison to the modified-modified Schober (MMS) Summary of Background : Numerous studies have evaluated the reliability and validity of the various methods of measuring spinal motion, but the results are inconsistent. Differences in equipment and techniques make it difficult to correlate results. Methods : Twenty subjects with back pain and twenty without back pain were selected through convenience sampling. Two examiners measured sagittal plane lumbar range of motion for each subject. Two separate tests with the CDI and one test with the MMS were conducted. Each test consisted of three trials. Instrument and examiner order was randomly assigned. Intra-class correlations (ICCs 2, 2 and 2, 2) and Pearson correlation coefficients (r) were used to calculate reliability and concurrent validity respectively. Results : Intra-trial reliability was high to very high for both the CDI (ICCs 0.85 - 0.96) and MMS (ICCs 0.84 - 0.98). However, the reliability was poor to moderate, when the CDI unit had to be repositioned either by the same rate (ICCs 0.16 - 0.59) or a different rater (ICCs 0.45 - 0.52). Inter-rater reliability for the MMS was moderate to high (ICCs 0.75 - 0.82) which bettered the moderate correlation obtained for the CDI (ICCs 0.45 - 0.52). Correlations between the CDI and MMS were poor for flexion (0.32; p<0.05) and poor to moderate (-0.42 - -0.51; p<0.05) for extension measurements. Conclusion : When using the CDI, an average of subsequent tests is required to obtain moderate reliability. The MMS was highly reliable than the CDI. The MMS and the CDI measure lumbar movement on a different metric that are not highly related to each other. PMID:25352928
Localized water reverberation phases and its impact on back-projection images
NASA Astrophysics Data System (ADS)
Yue, H.; Castillo, J.; Yu, C.; Meng, L.; Zhan, Z.
2017-12-01
Coherent radiators imaged by back-projections (BP) are commonly interpreted as part of the rupture process. Nevertheless, artifacts introduced by structure related phases are rarely discriminated from the rupture process. In this study, we adopt the logic of empirical Greens' function analysis (EGF) to discriminate between rupture and structure effect. We re-examine the waveforms and BP images of the 2012 Mw 7.2 Indian Ocean earthquake and an EGF event (Mw 6.2). The P wave codas of both events present similar shape with characteristic period of approximately 10 s, which are back-projected as coherent radiators near the trench. S wave BP doesn't image energy radiation near the trench. We interpret those coda waves as localized water reverberation phases excited near the trench. We perform a 2D waveform modeling using realistic bathymetry model, and find that the sharp near-trench bathymetry traps the acoustic water waves forming localized reverberation phases. These waves can be imaged as coherent near-trench radiators with similar features as that in the observations. We present a set of methodology to discriminate between the rupture and propagation effects in BP images, which can serve as a criterion of subevent identification.
Rupture Propagation Imaging of Fluid Induced Events at the Basel EGS Project
NASA Astrophysics Data System (ADS)
Folesky, Jonas; Kummerow, Jörn; Shapiro, Serge A.
2014-05-01
The analysis of rupture properties using rupture propagation imaging techniques is a fast developing field of research in global seismology. Usually rupture fronts of large to megathrust earthquakes are subject of recent studies, like e.g. the 2004 Sumatra-Andaman earthquake or the 2011 Tohoku, Japan earthquake. The back projection technique is the most prominent technique in this field. Here the seismograms recorded at an array or at a seismic network are back shifted to a grid of possible source locations via a special stacking procedure. This can provide information on the energy release and energy distribution of the rupture which then can be used to find estimates of event properties like location, rupture direction, rupture speed or length. The procedure is fast and direct and it only relies on a reasonable velocity model. Thus it is a good way to rapidly estimate the rupture properties and it can be used to confirm independently achieved event information. We adopted the back projection technique and put it in a microseismic context. We demonstrated its usage for multiple synthetic ruptures within a reservoir model of microseismic scale in earlier works. Our motivation hereby is the occurrence of relatively large, induced seismic events at a number of stimulated geothermal reservoirs or waste disposal sites, having magnitudes ML ≥ 3.4 and yielding rupture lengths of several hundred meters. We use the configuration of the seismic network and reservoir properties of the Basel Geothermal Site to build a synthetic model of a rupture by modeling the wave field of multiple spatio-temporal separated single sources using Finite-Difference modeling. The focus of this work is the application of the Back Projection technique and the demonstration of its feasibility to retrieve the rupture properties of real fluid induced events. We take four microseismic events with magnitudes from ML 3.1 to 3.4 and reconstruct source parameters like location, orientation and length. By comparison with our synthetic results as well as independent localization studies and source mechanism studies in this area we can show, that the obtained results are reasonable and that the application of back projection imaging is not only possible for microseismic datasets of respective quality, but that it provides important additional insights in the rupture process.
Single-strain-gage force/stiffness buckling prediction techniques on a hat-stiffened panel
NASA Technical Reports Server (NTRS)
Hudson, Larry D.; Thompson, Randolph C.
1991-01-01
Predicting the buckling characteristics of a test panel is necessary to ensure panel integrity during a test program. A single-strain-gage buckling prediction method was developed on a hat-stiffened, monolithic titanium buckling panel. The method is an adaptation of the original force/stiffness method which requires back-to-back gages. The single-gage method was developed because the test panel did not have back-to-back gages. The method was used to predict buckling loads and temperatures under various heating and loading conditions. The results correlated well with a finite element buckling analysis. The single-gage force/stiffness method was a valid real-time and post-test buckling prediction technique.
Students' Use of "Look Back" Strategies in Multiple Solution Methods
ERIC Educational Resources Information Center
Lee, Shin-Yi
2016-01-01
The purpose of this study was to investigate the relationship between both 9th-grade and 1st-year undergraduate students' use of "look back" strategies and problem solving performance in multiple solution methods, the difference in their use of look back strategies and problem solving performance in multiple solution methods, and the…
Jenkins, Hazel J.; Hancock, Mark J.; French, Simon D.; Maher, Chris G.; Engel, Roger M.; Magnussen, John S.
2015-01-01
Background: Rates of imaging for low-back pain are high and are associated with increased health care costs and radiation exposure as well as potentially poorer patient outcomes. We conducted a systematic review to investigate the effectiveness of interventions aimed at reducing the use of imaging for low-back pain. Methods: We searched MEDLINE, Embase, CINAHL and the Cochrane Central Register of Controlled Trials from the earliest records to June 23, 2014. We included randomized controlled trials, controlled clinical trials and interrupted time series studies that assessed interventions designed to reduce the use of imaging in any clinical setting, including primary, emergency and specialist care. Two independent reviewers extracted data and assessed risk of bias. We used raw data on imaging rates to calculate summary statistics. Study heterogeneity prevented meta-analysis. Results: A total of 8500 records were identified through the literature search. Of the 54 potentially eligible studies reviewed in full, 7 were included in our review. Clinical decision support involving a modified referral form in a hospital setting reduced imaging by 36.8% (95% confidence interval [CI] 33.2% to 40.5%). Targeted reminders to primary care physicians of appropriate indications for imaging reduced referrals for imaging by 22.5% (95% CI 8.4% to 36.8%). Interventions that used practitioner audits and feedback, practitioner education or guideline dissemination did not significantly reduce imaging rates. Lack of power within some of the included studies resulted in lack of statistical significance despite potentially clinically important effects. Interpretation: Clinical decision support in a hospital setting and targeted reminders to primary care doctors were effective interventions in reducing the use of imaging for low-back pain. These are potentially low-cost interventions that would substantially decrease medical expenditures associated with the management of low-back pain. PMID:25733741
10 CFR 609.6 - Submission of Applications.
Code of Federal Regulations, 2011 CFR
2011-01-01
... checklist for the equity and debt to the extent available; (16) Applicant's business plan on which the project is based and Applicant's financial model presenting project pro forma statements for the proposed... backing, together with business and financial interests of controlling or commonly controlled...
MATCON MODIFIED ASPHALT CONTAINMENT SYSTEM FOR MULTI-USE BROWNFIELDS
The concept of putting brownfield real estate back into safe and practical use is very appealing o both the owner and the neighborhood. Environmental regulations often preclude multi-use alterantives because traditional containment solutions rely on water barrier covers. These ar...
NASA Astrophysics Data System (ADS)
Allawi, Mohammed Falah; Jaafar, Othman; Mohamad Hamzah, Firdaus; Mohd, Nuruol Syuhadaa; Deo, Ravinesh C.; El-Shafie, Ahmed
2017-10-01
Existing forecast models applied for reservoir inflow forecasting encounter several drawbacks, due to the difficulty of the underlying mathematical procedures being to cope with and to mimic the naturalization and stochasticity of the inflow data patterns. In this study, appropriate adjustments to the conventional coactive neuro-fuzzy inference system (CANFIS) method are proposed to improve the mathematical procedure, thus enabling a better detection of the high nonlinearity patterns found in the reservoir inflow training data. This modification includes the updating of the back propagation algorithm, leading to a consequent update of the membership rules and the induction of the centre-weighted set rather than the global weighted set used in feature extraction. The modification also aids in constructing an integrated model that is able to not only detect the nonlinearity in the training data but also the wide range of features within the training data records used to simulate the forecasting model. To demonstrate the model's efficacy, the proposed CANFIS method has been applied to forecast monthly inflow data at Aswan High Dam (AHD), located in southern Egypt. Comparative analyses of the forecasting skill of the modified CANFIS and the conventional ANFIS model are carried out with statistical score indicators to assess the reliability of the developed method. The statistical metrics support the better performance of the developed CANFIS model, which significantly outperforms the ANFIS model to attain a low relative error value (23%), mean absolute error (1.4 BCM month-1), root mean square error (1.14 BCM month-1), and a relative large coefficient of determination (0.94). The present study ascertains the better utility of the modified CANFIS model in respect to the traditional ANFIS model applied in reservoir inflow forecasting for a semi-arid region.
Ojukwu, Chidiebele Petronilla; Anyanwu, Godson Emeka; Anekwu, Emelie Morris; Chukwu, Sylvester Caesar; Fab-Agbo, Chukwubuikem
2017-10-01
Infant carrying is an integral part of the mothering occupation. Paucity of data exists on its correlates and associated musculoskeletal injuries. In this study, factors and musculoskeletal injuries associated with infant carrying were investigated in 227 nursing mothers, using a structured questionnaire. 77.1% utilised the back infant carrying methods (ICM). Maternal comfort was the major factor influencing participants' (37.4%) choices of ICMs. Infant's age (p = .000) and transportation means (p = .045) were significantly associated with ICMs. Low back pain (82.8%) and upper back pain (74.9%) were the most reported musculoskeletal discomforts associated with ICMs, especially among women who utilised back ICM. Back ICM is predominantly used by nursing mothers. Impact statement Infant carrying has been associated with increased energy cost and biomechanical changes. Currently, there is a paucity of data on infant carrying-related musculoskeletal injuries. In this study, investigating factors and musculoskeletal injuries associated with infant carrying, the results showed that back infant carrying method is predominantly used by nursing mothers. Age of the infant and mothers' means of transportation were determinant factors of infant carrying methods. Among the several reported infant carrying-related musculoskeletal disorders, low back and upper back pain were the most prevalent, especially among women who utilised the back infant carrying method. There is need for women's health specialists to introduce appropriate ergonomic training and interventions on infant carrying tasks in order to improve maternal musculoskeletal health during the childbearing years and beyond. Further experimental studies on the effects of various infant carrying methods on the musculoskeletal system are recommended.
Work activities and musculoskeletal complaints among preschool workers.
Grant, K A; Habes, D J; Tepper, A L
1995-12-01
The potential for musculoskeletal trauma among preschool workers has been largely unexplored in the United States. This case report describes an investigation conducted to identify and evaluate possible causes of back and lower extremity pain among 22 workers at a Montessori day care facility. Investigators met with and distributed a questionnaire to school employees, and made measurements of workstation and furniture dimensions. Investigators also recorded the normal work activities of school employees on videotape, and performed a work sampling study to estimate the percentage of time employees spend performing various tasks and in certain postures. Questionnaire results from 18 employees indicated that back pain/discomfort was a common musculoskeletal complaint, reported by 61% of respondents. Neck/shoulder pain, lower extremity pain and hand/wrist pain were reported by 33, 33 and 11% of respondents, respectively. Observation and analysis of work activities indicated that employees spend significant periods of time kneeling, sitting on the floor, squatting, or bending at the waist. Furthermore, staff members who work with smaller children (i.e. six weeks to 18 months of age) performed more lifts and assumed more awkward lower extremity postures than employees who work with older children (3-4 years of age). Analysis of two lifting tasks using the revised NIOSH lifting equation indicated that employees who handle small children may be at increased risk of lifting-related low back pain. Investigators concluded that day care employees at this facility are at increased risk of low back pain and lower extremity (i.e. knee) injury due to work activities that require awkward or heavy lifts, and static working postures. Recommendations for reducing or eliminating these risks by modifying the workplace and changing the organization and methods of work are presented.
Crumb rubber modified asphalt concrete in Oregon : summary report.
DOT National Transportation Integrated Search
1995-07-01
Over the last nine years, the Oregon Department of Transportation (ODOT) has constructed 13 projects using crumb rubber modifiers (CRMs) in asphalt concrete pavements using both the wet and dry process. Three of the projects included more than one ty...
Evaluation of modified work zone traffic control devices at business accesses
DOT National Transportation Integrated Search
2001-01-01
Modified work zone traffic control devices at business accesses were evaluated on two Oregon Department of Transportation (ODOT) projects in 1999 and 2000. On one section project, blue Temporary Business Access" signs were used at business accesses d...
A phase coherence approach to identifying co-located earthquakes and tremor
NASA Astrophysics Data System (ADS)
Hawthorne, J. C.; Ampuero, J.-P.
2018-05-01
We present and use a phase coherence approach to identify seismic signals that have similar path effects but different source time functions: co-located earthquakes and tremor. The method used is a phase coherence-based implementation of empirical matched field processing, modified to suit tremor analysis. It works by comparing the frequency-domain phases of waveforms generated by two sources recorded at multiple stations. We first cross-correlate the records of the two sources at a single station. If the sources are co-located, this cross-correlation eliminates the phases of the Green's function. It leaves the relative phases of the source time functions, which should be the same across all stations so long as the spatial extent of the sources are small compared with the seismic wavelength. We therefore search for cross-correlation phases that are consistent across stations as an indication of co-located sources. We also introduce a method to obtain relative locations between the two sources, based on back-projection of interstation phase coherence. We apply this technique to analyse two tremor-like signals that are thought to be composed of a number of earthquakes. First, we analyse a 20 s long seismic precursor to a M 3.9 earthquake in central Alaska. The analysis locates the precursor to within 2 km of the mainshock, and it identifies several bursts of energy—potentially foreshocks or groups of foreshocks—within the precursor. Second, we examine several minutes of volcanic tremor prior to an eruption at Redoubt Volcano. We confirm that the tremor source is located close to repeating earthquakes identified earlier in the tremor sequence. The amplitude of the tremor diminishes about 30 s before the eruption, but the phase coherence results suggest that the tremor may persist at some level through this final interval.
Estimation of low back moments from video analysis: a validation study.
Coenen, Pieter; Kingma, Idsart; Boot, Cécile R L; Faber, Gert S; Xu, Xu; Bongers, Paulien M; van Dieën, Jaap H
2011-09-02
This study aimed to develop, compare and validate two versions of a video analysis method for assessment of low back moments during occupational lifting tasks since for epidemiological studies and ergonomic practice relatively cheap and easily applicable methods to assess low back loads are needed. Ten healthy subjects participated in a protocol comprising 12 lifting conditions. Low back moments were assessed using two variants of a video analysis method and a lab-based reference method. Repeated measures ANOVAs showed no overall differences in peak moments between the two versions of the video analysis method and the reference method. However, two conditions showed a minor overestimation of one of the video analysis method moments. Standard deviations were considerable suggesting that errors in the video analysis were random. Furthermore, there was a small underestimation of dynamic components and overestimation of the static components of the moments. Intraclass correlations coefficients for peak moments showed high correspondence (>0.85) of the video analyses with the reference method. It is concluded that, when a sufficient number of measurements can be taken, the video analysis method for assessment of low back loads during lifting tasks provides valid estimates of low back moments in ergonomic practice and epidemiological studies for lifts up to a moderate level of asymmetry. Copyright © 2011 Elsevier Ltd. All rights reserved.
Foo, Ning-Ping; Chang, Jer-Hao; Su, Shih-Bin; Chen, Kow-Tong; Cheng, Ching-Fa; Chen, Pei-Chung; Lin, Tsung-Yi; Guo, How-Ran
2014-01-01
The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain.
Reconstructing Buildings with Discontinuities and Roof Overhangs from Oblique Aerial Imagery
NASA Astrophysics Data System (ADS)
Frommholz, D.; Linkiewicz, M.; Meissner, H.; Dahlke, D.
2017-05-01
This paper proposes a two-stage method for the reconstruction of city buildings with discontinuities and roof overhangs from oriented nadir and oblique aerial images. To model the structures the input data is transformed into a dense point cloud, segmented and filtered with a modified marching cubes algorithm to reduce the positional noise. Assuming a monolithic building the remaining vertices are initially projected onto a 2D grid and passed to RANSAC-based regression and topology analysis to geometrically determine finite wall, ground and roof planes. If this should fail due to the presence of discontinuities the regression will be repeated on a 3D level by traversing voxels within the regularly subdivided bounding box of the building point set. For each cube a planar piece of the current surface is approximated and expanded. The resulting segments get mutually intersected yielding both topological and geometrical nodes and edges. These entities will be eliminated if their distance-based affiliation to the defining point sets is violated leaving a consistent building hull including its structural breaks. To add the roof overhangs the computed polygonal meshes are projected onto the digital surface model derived from the point cloud. Their shapes are offset equally along the edge normals with subpixel accuracy by detecting the zero-crossings of the second-order directional derivative in the gradient direction of the height bitmap and translated back into world space to become a component of the building. As soon as the reconstructed objects are finished the aerial images are further used to generate a compact texture atlas for visualization purposes. An optimized atlas bitmap is generated that allows perspectivecorrect multi-source texture mapping without prior rectification involving a partially parallel placement algorithm. Moreover, the texture atlases undergo object-based image analysis (OBIA) to detect window areas which get reintegrated into the building models. To evaluate the performance of the proposed method a proof-of-concept test on sample structures obtained from real-world data of Heligoland/Germany has been conducted. It revealed good reconstruction accuracy in comparison to the cadastral map, a speed-up in texture atlas optimization and visually attractive render results.
2012-01-01
Background Chronic low back pain (CLBP) experienced in middle-age may have important implications for vertebral bone health, although this issue has not been investigated as a primary aim previously. This study investigated the associations between CLBP and dual energy X-ray absorptiometry (DXA)-derived vertebral bone mineral measures acquired from postero-anterior and lateral-projections, among community-dwelling, middle-aged adults. Methods Twenty-nine adults with CLBP (11 male, 18 female) and 42 adults with no history of LBP in the preceding year (17 male, 25 female) were evaluated. Self-reported demographic and clinical data were collected via questionnaires. Areal bone mineral density (aBMD) was measured in the lumbar spine by DXA. Apparent volumetric (ap.v) BMD in the lumbar spine was also calculated. Multiple linear regression models were used to examine associations between study group (CLBP and control) and vertebral DXA variables by gender, adjusting for height, mass and age. Results There was no difference between groups by gender in anthropometrics or clinical characteristics. In the CLBP group, the mean (SD) duration of CLBP was 13.3 (10.4) years in males and 11.6 (9.9) years in females, with Oswestry Disability Index scores of 16.2 (8.7)% and 15.4 (9.1)%, respectively. Males with CLBP had significantly lower adjusted lateral-projection aBMD and lateral-projection ap.vBMD than controls at L3 with mean differences (standard error) of 0.09 (0.04) g/cm2 (p = 0.03) and 0.02 (0.01) g/cm3 (p = 0.04). These multivariate models accounted for 55% and 53% of the variance in lateral-projection L3 aBMD and lateral-projection L3 ap.vBMD. Conclusions CLBP in males is associated with some lumbar vertebral BMD measures, raising important questions about the mechanism and potential clinical impact of this association. PMID:22458361
Saper, Robert B; Sherman, Karen J; Delitto, Anthony; Herman, Patricia M; Stevans, Joel; Paris, Ruth; Keosaian, Julia E; Cerrada, Christian J; Lemaster, Chelsey M; Faulkner, Carol; Breuer, Maya; Weinberg, Janice
2014-02-26
Chronic low back pain causes substantial morbidity and cost to society while disproportionately impacting low-income and minority adults. Several randomized controlled trials show yoga is an effective treatment. However, the comparative effectiveness of yoga and physical therapy, a common mainstream treatment for chronic low back pain, is unknown. This is a randomized controlled trial for 320 predominantly low-income minority adults with chronic low back pain, comparing yoga, physical therapy, and education. Inclusion criteria are adults 18-64 years old with non-specific low back pain lasting ≥ 12 weeks and a self-reported average pain intensity of ≥ 4 on a 0-10 scale. Recruitment takes place at Boston Medical Center, an urban academic safety-net hospital and seven federally qualified community health centers located in diverse neighborhoods. The 52-week study has an initial 12-week Treatment Phase where participants are randomized in a 2:2:1 ratio into i) a standardized weekly hatha yoga class supplemented by home practice; ii) a standardized evidence-based exercise therapy protocol adapted from the Treatment Based Classification method, individually delivered by a physical therapist and supplemented by home practice; and iii) education delivered through a self-care book. Co-primary outcome measures are 12-week pain intensity measured on an 11-point numerical rating scale and back-specific function measured using the modified Roland Morris Disability Questionnaire. In the subsequent 40-week Maintenance Phase, yoga participants are re-randomized in a 1:1 ratio to either structured maintenance yoga classes or home practice only. Physical therapy participants are similarly re-randomized to either five booster sessions or home practice only. Education participants continue to follow recommendations of educational materials. We will also assess cost effectiveness from the perspectives of the individual, insurers, and society using claims databases, electronic medical records, self-report cost data, and study records. Qualitative data from interviews will add subjective detail to complement quantitative data. This trial is registered in ClinicalTrials.gov, with the ID number: NCT01343927.
2010-01-01
Background Current evidence supports the use of exercise-based treatment for chronic low back pain that encourages the patient to assume an active role in their recovery. Walking has been shown it to be an acceptable type of exercise with a low risk of injury. However, it is not known whether structured physical activity programmes are any more effective than giving advice to remain active. Methods/Design The proposed study will test the feasibility of using a pedometer-driven walking programme, as an adjunct to a standard education and advice session in participants with chronic low back pain. Fifty adult participants will be recruited via a number of different sources. Baseline outcome measures including self reported function; objective physical activity levels; fear-avoidance beliefs and health-related quality of life will be recorded. Eligible participants will be randomly allocated under strict, double blind conditions to one of two treatments groups. Participants in group A will receive a single education and advice session with a physiotherapist based on the content of the 'Back Book'. Participants in group B will receive the same education and advice session. In addition, they will also receive a graded pedometer-driven walking programme prescribed by the physiotherapist. Follow up outcomes will be recorded by the same researcher, who will remain blinded to group allocation, at eight weeks and six months post randomisation. A qualitative exploration of participants' perception of walking will also be examined by use of focus groups at the end of the intervention. As a feasibility study, treatment effects will be represented by point estimates and confidence intervals. The assessment of participant satisfaction will be tabulated, as will adherence levels and any recorded difficulties or adverse events experienced by the participants or therapists. This information will be used to modify the planned interventions to be used in a larger randomised controlled trial. Discussion This paper describes the rationale and design of a study which will test the feasibility of using a structured, pedometer-driven walking programme in participants with chronic low back pain. Trial Registration [ISRCTN67030896] PMID:20633256
77 FR 69928 - Transco Railway Products Inc.-Acquisition and Operation Exemption-D&W Railroad LLC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... as the ``Depress Track,'' the ``Back Lead,'' and the ``Freight Track'' (the Freight Track leads to... the Freight Track to the Back Lead track).\\1\\ The tracks are located west of the main line, north of... qualify it as a Class III rail carrier, and further states that its projected annual revenue would not...
Explicit methods in extended phase space for inseparable Hamiltonian problems
NASA Astrophysics Data System (ADS)
Pihajoki, Pauli
2015-03-01
We present a method for explicit leapfrog integration of inseparable Hamiltonian systems by means of an extended phase space. A suitably defined new Hamiltonian on the extended phase space leads to equations of motion that can be numerically integrated by standard symplectic leapfrog (splitting) methods. When the leapfrog is combined with coordinate mixing transformations, the resulting algorithm shows good long term stability and error behaviour. We extend the method to non-Hamiltonian problems as well, and investigate optimal methods of projecting the extended phase space back to original dimension. Finally, we apply the methods to a Hamiltonian problem of geodesics in a curved space, and a non-Hamiltonian problem of a forced non-linear oscillator. We compare the performance of the methods to a general purpose differential equation solver LSODE, and the implicit midpoint method, a symplectic one-step method. We find the extended phase space methods to compare favorably to both for the Hamiltonian problem, and to the implicit midpoint method in the case of the non-linear oscillator.
ERIC Educational Resources Information Center
Asperin, Amelia Estepa; Castillo, Alexandra
2010-01-01
Purpose/Objectives: The purpose of this project was to identify and confirm best practices for increasing high school student participation and satisfaction in school nutrition (SN) programs operating under the regulations of the National School Lunch Program (NSLP). Methods: Using a modified best practices research model (BPRM; Mold & Gregory,…
Robert E. Keane; Pamela G. Sikkink; Theresa B. Jain
2018-01-01
Mastication is a wildland fuel treatment technique that is rapidly becoming the preferred method for many fire hazard reduction projects, especially in areas where reducing fuels with prescribed fire is particularly challenging. Mastication is the process of mechanically modifying the live and dead surface and canopy biomass by chopping and shredding vegetation to...
NASA Astrophysics Data System (ADS)
Lee, Haenghwa; Choi, Sunghoon; Jo, Byungdu; Kim, Hyemi; Lee, Donghoon; Kim, Dohyeon; Choi, Seungyeon; Lee, Youngjin; Kim, Hee-Joung
2017-03-01
Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve the detection of subtle lung disease over conventional chest radiography. Algorithm development for CDT system is challenging in that a limited number of low-dose projections are acquired over a limited angular range. To confirm the feasibility of algebraic reconstruction technique (ART) method under variations in key imaging parameters, quality metrics were conducted using LUNGMAN phantom included grand-glass opacity (GGO) tumor. Reconstructed images were acquired from the total 41 projection images over a total angular range of +/-20°. We evaluated contrast-to-noise ratio (CNR) and artifacts spread function (ASF) to investigate the effect of reconstruction parameters such as number of iterations, relaxation parameter and initial guess on image quality. We found that proper value of ART relaxation parameter could improve image quality from the same projection. In this study, proper value of relaxation parameters for zero-image (ZI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. Also, the maximum CNR values and the minimum full width at half maximum (FWHM) of ASF were acquired in the reconstructed images after 20 iterations and 3 iterations, respectively. According to the results, BP initial guess for ART method could provide better image quality than ZI initial guess. In conclusion, ART method with proper reconstruction parameters could improve image quality due to the limited angular range in CDT system.
26 CFR 1.460-6 - Look-back method.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 6 2011-04-01 2011-04-01 false Look-back method. 1.460-6 Section 1.460-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxable Year for Which Items of Gross Income Included § 1.460-6 Look-back method. (a) In general—(1) Introduction. With...
26 CFR 1.460-6 - Look-back method.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 6 2014-04-01 2014-04-01 false Look-back method. 1.460-6 Section 1.460-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxable Year for Which Items of Gross Income Included § 1.460-6 Look-back method. (a) In general—(1) Introduction. With...
26 CFR 1.460-6 - Look-back method.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 6 2012-04-01 2012-04-01 false Look-back method. 1.460-6 Section 1.460-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxable Year for Which Items of Gross Income Included § 1.460-6 Look-back method. (a) In general—(1) Introduction. With...
Simulating the electrohydrodynamics of a viscous droplet
NASA Astrophysics Data System (ADS)
Theillard, Maxime; Saintillan, David
2016-11-01
We present a novel numerical approach for the simulation of viscous drop placed in an electric field in two and three spatial dimensions. Our method is constructed as a stable projection method on Quad/Octree grids. Using a modified pressure correction we were able to alleviate the standard time step restriction incurred by capillary forces. In weak electric fields, our results match remarkably well with the predictions from the Taylor-Melcher leaky dielectric model. In strong electric fields the so-called Quincke rotation is correctly reproduced.
The Videodisc as a Pilot Project of the Public Archives of Canada.
ERIC Educational Resources Information Center
Mole, Dennis
1981-01-01
Discusses a project in which a large variety of materials from the collection of the Canadian Public Archives were recorded and played back using laser optical videodisc technology. The videodisc's capabilities for preserving, storing, and retrieving information are discussed. (Author/JJD)
Systematic, Multimethod Assessment of Adaptations Across Four Diverse Health Systems Interventions.
Rabin, Borsika A; McCreight, Marina; Battaglia, Catherine; Ayele, Roman; Burke, Robert E; Hess, Paul L; Frank, Joseph W; Glasgow, Russell E
2018-01-01
Many health outcomes and implementation science studies have demonstrated the importance of tailoring evidence-based care interventions to local context to improve fit. By adapting to local culture, history, resources, characteristics, and priorities, interventions are more likely to lead to improved outcomes. However, it is unclear how best to adapt evidence-based programs and promising innovations. There are few guides or examples of how to best categorize or assess health-care adaptations, and even fewer that are brief and practical for use by non-researchers. This study describes the importance and potential of assessing adaptations before, during, and after the implementation of health systems interventions. We present a promising multilevel and multimethod approach developed and being applied across four different health systems interventions. Finally, we discuss implications and opportunities for future research. The four case studies are diverse in the conditions addressed, interventions, and implementation strategies. They include two nurse coordinator-based transition of care interventions, a data and training-driven multimodal pain management project, and a cardiovascular patient-reported outcomes project, all of which are using audit and feedback. We used the same modified adaptation framework to document changes made to the interventions and implementation strategies. To create the modified framework, we started with the adaptation and modification model developed by Stirman and colleagues and expanded it by adding concepts from the RE-AIM framework. Our assessments address the intuitive domains of Who, How, When, What, and Why to classify and organize adaptations. For each case study, we discuss how the modified framework was operationalized, the multiple methods used to collect data, results to date and approaches utilized for data analysis. These methods include a real-time tracking system and structured interviews at key times during the intervention. We provide descriptive data on the types and categories of adaptations made and discuss lessons learned. The multimethod approaches demonstrate utility across diverse health systems interventions. The modified adaptations model adequately captures adaptations across the various projects and content areas. We recommend systematic documentation of adaptations in future clinical and public health research and have made our assessment materials publicly available.
NASA Astrophysics Data System (ADS)
Esfahanian, Farzane; Amoozadeh, Ali; Bitaraf, Mehrnoosh
2018-06-01
This study has represented an easy and inexpensive method for the synthesis of a new basic nanocatalyst. In this regard, 3-dimethylaminopropylamine (DMAPA), an economic, industrial, and readily obtainable basic compound, has been grafted onto nano-titania particles by the use of 2,4-toluene diisocyanate (TDI) as a bi-functional, inexpensive, and highly reactive linker. The prepared catalyst has been characterized using the spectroscopic FT-IR method, XRD, FE-SEM, EDX, and back titration. Furthermore, it was identified as an effective catalyst in the preparation of DHPM derivatives and pyranopyrazoles which results in high purity and high yields of products. Response surface methodology (RSM) based on a central composite design (CCD) was employed to reach the optimal conditions. The catalyst can be readily separated and recycled up to six times. [Figure not available: see fulltext.
Synthesis of an un-supported, high-flow ZSM-22 zeolite membrane
Thoma, Steven G [Albuquerque, NM; Nenoff, Tina M [Albuquerque, NM
2006-10-10
Novel methods for synthesizing wholly un-supported, high-flow catalytic membranes consisting of 100% crystalline ZSM-22 crystals with no binder phase, having sufficient porosity to allow high Weight Hourly Space Velocities of feedstock to pass through without generating back pressure. The ZSM-22 membranes perform favorably to existing bulk ZSM-22 catalysts (e.g., via 1-butene conversion and selectivity). The method of membrane synthesis, based on Vapor Phase Transport, allows free-standing, binder-less membranes to be fabricated in varied geometries and sizes so that membranes can be tailor-made for particular geometries applications. The ZSM-22 precursor gel may be consolidated into a semi-cohesive body prior to vapor phase crystallization, for example, by uniaxial pressing. These crystalline membranes may be modified by ion exchange, pore ion exchange, framework exchange, synthesis modification techniques to incorporate other elements into the framework, such as K, H, Mg, Zn, V, Ga, and Pt.
Shen, Junlin; Du, Xiangying; Guo, Daode; Cao, Lizhen; Gao, Yan; Yang, Qi; Li, Pengyu; Liu, Jiabin; Li, Kuncheng
2013-01-01
Objectives To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). Materials and Methods We performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113), noise-based tube current with filtered back projection (Group 2, n = 109) or with iterative reconstruction (Group 3, n = 116). Tube voltage was fixed at 120 kV. Qualitative image quality was rated on a 5-point scale (1 = impaired, to 5 = excellent, with 3–5 defined as diagnostic). Image noise and signal intensity were measured; signal-to-noise ratio was calculated; radiation dose parameters were recorded. Statistical analyses included one-way analysis of variance, chi-square test, Kruskal-Wallis test and multivariable linear regression. Results Image noise was maintained at the target value of 35HU with small interquartile range for Group 2 (35.00–35.03HU) and Group 3 (34.99–35.02HU), while from 28.73 to 37.87HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 20% and 51% reduction in effective dose for Group 2 (2.9 mSv) and Group 3 (1.8 mSv) were achieved compared with Group 1 (3.7 mSv). After adjustment for scan characteristics, iterative reconstruction was associated with 26% reduction in effective dose. Conclusion Noise-based tube current reduction method with iterative reconstruction maintains image noise precisely at the desired level and achieves consistent image quality. Meanwhile, effective dose can be reduced by more than 50%. PMID:23741444
Beam hardening correction in CT myocardial perfusion measurement
NASA Astrophysics Data System (ADS)
So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Lee, Ting-Yim
2009-05-01
This paper presents a method for correcting beam hardening (BH) in cardiac CT perfusion imaging. The proposed algorithm works with reconstructed images instead of projection data. It applies thresholds to separate low (soft tissue) and high (bone and contrast) attenuating material in a CT image. The BH error in each projection is estimated by a polynomial function of the forward projection of the segmented image. The error image is reconstructed by back-projection of the estimated errors. A BH-corrected image is then obtained by subtracting a scaled error image from the original image. Phantoms were designed to simulate the BH artifacts encountered in cardiac CT perfusion studies of humans and animals that are most commonly used in cardiac research. These phantoms were used to investigate whether BH artifacts can be reduced with our approach and to determine the optimal settings, which depend upon the anatomy of the scanned subject, of the correction algorithm for patient and animal studies. The correction algorithm was also applied to correct BH in a clinical study to further demonstrate the effectiveness of our technique.
Sampling limits for electron tomography with sparsity-exploiting reconstructions.
Jiang, Yi; Padgett, Elliot; Hovden, Robert; Muller, David A
2018-03-01
Electron tomography (ET) has become a standard technique for 3D characterization of materials at the nano-scale. Traditional reconstruction algorithms such as weighted back projection suffer from disruptive artifacts with insufficient projections. Popularized by compressed sensing, sparsity-exploiting algorithms have been applied to experimental ET data and show promise for improving reconstruction quality or reducing the total beam dose applied to a specimen. Nevertheless, theoretical bounds for these methods have been less explored in the context of ET applications. Here, we perform numerical simulations to investigate performance of ℓ 1 -norm and total-variation (TV) minimization under various imaging conditions. From 36,100 different simulated structures, our results show specimens with more complex structures generally require more projections for exact reconstruction. However, once sufficient data is acquired, dividing the beam dose over more projections provides no improvements-analogous to the traditional dose-fraction theorem. Moreover, a limited tilt range of ±75° or less can result in distorting artifacts in sparsity-exploiting reconstructions. The influence of optimization parameters on reconstructions is also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Rate-based congestion control in networks with smart links, revision. B.S. Thesis - May 1988
NASA Technical Reports Server (NTRS)
Heybey, Andrew Tyrrell
1990-01-01
The author uses a network simulator to explore rate-based congestion control in networks with smart links that can feed back information to tell senders to adjust their transmission rates. This method differs in a very important way from congestion control in which a congested network component just drops packets - the most commonly used method. It is clearly advantageous for the links in the network to communicate with the end users about the network capacity, rather than the users unilaterally picking a transmission rate. The components in the middle of the network, not the end users, have information about the capacity and traffic in the network. The author experiments with three different algorithms for calculating the control rate to feed back to the users. All of the algorithms exhibit problems in the form of large queues when simulated with a configuration modeling the dynamics of a packet-voice system. However, the problems are not with the algorithms themselves, but with the fact that feedback takes time. If the network steady-state utilization is low enough that it can absorb transients in the traffic through it, then the large queues disappear. If the users are modified to start sending slowly, to allow the network to adapt to a new flow without causing congestion, a greater portion of the network's bandwidth can be used.
NASA Astrophysics Data System (ADS)
Dominik, Michael T.
The success of a project is dependent in part on the skills, knowledge, and behavior of its leader, the project manager. Despite advances in project manager certifications and professional development, the aerospace and defense industry has continued to see highly visible and expensive project failures partially attributable to failures in leadership. Servant leadership is an emerging leadership theory whose practitioners embrace empowerment, authenticity, humility, accountability, forgiveness, courage, standing back, and stewardship, but has not yet been fully examined in the context of the project manager as leader. The objective of this study was to examine the relationship between servant leadership behaviors demonstrated by aerospace and defense project managers and the resulting success of their projects. Study participants were drawn from aerospace and defense oriented affinity groups from the LinkedInRTM social media web system. The participants rated their project managers using a 30-item servant leadership scale, and rated the success of their project using a 12-item project success scale. One hundred and fifteen valid responses were analyzed from 231 collected samples from persons who had worked for a project manager on an aerospace and defense project within the past year. The results of the study demonstrated statistically significant levels of positive correlation to project success for all eight servant leadership factors independently evaluated. Using multiple linear regression methods, the servant leadership factors of empowerment and authenticity were determined to be substantial and statistically significant predictors of project success. The study results established the potential application of servant leadership as a valid approach for improving outcomes of projects.
Relational Processing Following Stroke
ERIC Educational Resources Information Center
Andrews, Glenda; Halford, Graeme S.; Shum, David; Maujean, Annick; Chappell, Mark; Birney, Damian
2013-01-01
The research examined relational processing following stroke. Stroke patients (14 with frontal, 30 with non-frontal lesions) and 41 matched controls completed four relational processing tasks: sentence comprehension, Latin square matrix completion, modified Dimensional Change Card Sorting, and n-back. Each task included items at two or three…
There and Back Again: An Acquisition Study
ERIC Educational Resources Information Center
Xu, Ting; Snyder, William
2017-01-01
When "again" modifies an English goal-PP construction, the sentence is ambiguous between a repetitive and a restitutive reading. Interestingly, languages vary in whether their counterpart to English "again" permits a restitutive reading with goal-PP constructions (Beck 2005; Beck & Snyder 2001). This article explores how…
A direct force model for Galilean invariant lattice Boltzmann simulation of fluid-particle flows
NASA Astrophysics Data System (ADS)
Tao, Shi; He, Qing; Chen, Baiman; Yang, Xiaoping; Huang, Simin
The lattice Boltzmann method (LBM) has been widely used in the simulation of particulate flows involving complex moving boundaries. Due to the kinetic background of LBM, the bounce-back (BB) rule and the momentum exchange (ME) method can be easily applied to the solid boundary treatment and the evaluation of fluid-solid interaction force, respectively. However, recently it has been found that both the BB and ME schemes may violate the principle of Galilean invariance (GI). Some modified BB and ME methods have been proposed to reduce the GI error. But these remedies have been recognized subsequently to be inconsistent with Newton’s Third Law. Therefore, contrary to those corrections based on the BB and ME methods, a unified iterative approach is adopted to handle the solid boundary in the present study. Furthermore, a direct force (DF) scheme is proposed to evaluate the fluid-particle interaction force. The methods preserve the efficiency of the BB and ME schemes, and the performance on the accuracy and GI is verified and validated in the test cases of particulate flows with freely moving particles.
[Evaluation of the German new back school: pain-related and psychological characteristics].
Borys, C; Nodop, S; Tutzschke, R; Anders, C; Scholle, H C; Strauß, B
2013-12-01
Results related to the outcome of the classical back schools are inconsistent. Accordingly, a reformulation of the program integrating psychological and social aspects was performed as a necessary step for the development of the new back school in Germany. The aim of this study was to assess the effectiveness and sustainability of the new back school in subjects with non-specific back pain in the prevention setting. In a modified waiting design, individuals were investigated with respect to demographical, pain-related and psychological characteristics 3 months before the start, at the start and at the end of the back school and as well as 12 months after completion. In addition, predictors for a successful participation were analyzed. A total of 88 subjects with back pain initially participated in the study. In the short and long-term course, low to moderate effects were detected; however, during follow-up a reduction of pain showed high effects. Depression as assessed by the hospital anxiety and depression scale (HADS) and passive coping strategies assessed using the coping strategies questionnaire (CSQ) were identified as predictors for response to the intervention. On the basis of the sample studied, the new back school proved to be an effective treatment for short and long-term reduction of pain-related stress and associated psychological aspects. Maladaptive, passive coping strategies and higher depression scores were associated with a higher probability of success in terms of pain reduction and functional improvement.
2017-01-01
Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818
Thanawat, Thanakorn; Nualnetr, Nomjit
2017-01-01
Chronic low back pain (LBP) can be managed by exercises which should be tailored to an individual's readiness to behavioral change. To evaluate the effects of an intervention program based on the Transtheoretical Model of behavioral change (TTM) on back muscle endurance, physical function and pain in rice farmers with chronic LBP. In a 32-week study, 126 rice farmers were allocated to the TTM (n= 62) and non-TTM (n= 64) groups. Modified Biering-Sorensen test, Oswestry Disability Questionnaire and visual analogue scale were used for evaluating back muscle endurance, physical function and severity of pain, respectively. The evaluations were performed at baseline and at weeks 8, 20 and 32 of the study. Data were analyzed using repeated measure ANOVA. The back muscle endurance was significantly greater in the TTM group than in the non-TTM group at week 32 (p= 0.025). Physical function and severity of pain were significantly improved in the TTM group when compared with the non-TTM group at weeks 20 and 32 (p< 0.01). A TTM-based intervention could improve back muscle endurance and physical function, and reduce the pain in rice farmers with LBP. Further studies should be considered to explore the long-term effects of this intervention.
Prevalence of low back pain in emergency settings: a systematic review and meta-analysis.
Edwards, Jordan; Hayden, Jill; Asbridge, Mark; Gregoire, Bruce; Magee, Kirk
2017-04-04
Low back pain may be having a significant impact on emergency departments around the world. Research suggests low back pain is one of the leading causes of emergency department visits. However, in the peer-reviewed literature, there has been limited focus on the prevalence and management of back pain in the emergency department setting. The aim of the systematic review was to synthesize evidence about the prevalence of low back pain in emergency settings and explore the impact of study characteristics including type of emergency setting and how the study defined low back pain. Studies were identified from PubMed and EMBASE, grey literature search, and other sources. We selected studies that presented prevalence data for adults presenting to an emergency setting with low back pain. Critical appraisal was conducted using a modified tool developed to assess prevalence studies. Meta-analyses and a meta-regression explored the influence of study-level characteristics on prevalence. We screened 1187 citations and included 21 studies, reported between 2000 and 2016 presenting prevalence data from 12 countries. The pooled prevalence estimate from studies of standard emergency settings was 4.39% (95% CI: 3.67-5.18). Prevalence estimates of the included studies ranged from 0.9% to 17.1% and varied with study definition of low back pain and the type of emergency setting. The overall quality of the evidence was judged to be moderate as there was limited generalizability and high heterogeneity in the results. This is the first systematic review to examine the prevalence of low back pain in emergency settings. Our results indicate that low back pain is consistently a top presenting complaint and that the prevalence of low back pain varies with definition of low back pain and emergency setting. Clinicians and policy decisions makers should be aware of the potential impact of low back pain in their emergency settings.
Atalay, Erdem; Akova, Bedrettin; Gür, Hakan; Sekir, Ufuk
2017-12-01
The present study aimed to analyze the impacts of a low back rehabilitation program accompanied with neck, shoulder and upper back exercises on pain, disability, and physical characteristics of patients with chronic low back pain. Twenty sedentary male patients with chronic low back pain participated in the study on a voluntary basis. The patients were randomly allocated into two groups: a conventional low back exercise group (CE) and a supported exercise group (SE; CE plus upper back, neck, and shoulder exercises). The Modified Oswestry Disability Questionnaire (MODQ) was used to evaluate the disability status and the Visual Analog Scale (VAS) was used to identify the pain states of the patients. In addition, neck, lumbar and shoulder isokinetic and isometric strengths of the patients were evaluated. The CE group performed lumbar stretching, mobilization and stabilization exercises in addition to low-back and abdominal isometric and concentric strengthening exercises. The SE group performed static stretching and isotonic exercises for the neck, upper-back, and shoulder muscles, in addition to the exercises performed in CE group. The exercises were implemented 3 days a week for 6 weeks in both groups. Following the 6-week exercise periods in both groups, statistically significant (p < 0.01) improvements were observed in the patients' levels of pain and the scores of MODQ reflecting an easing of disability. With respect to the levels of pain and disability, the improvements observed in the SE group was significantly (p < 0.01) greater than the improvement observed in the CE group. Based on the findings of this study, we can conclude that a low back exercise program used in combination with neck, shoulder and upper back exercises reduces the level of pain and disability in patients with chronic low back pain more prominently than conventional low back exercises.
Mid-infrared spectroscopy for characterization of Baltic amber (succinite)
NASA Astrophysics Data System (ADS)
Wagner-Wysiecka, Ewa
2018-05-01
Natural Baltic amber (succinite) is the most appreciated fossil resin of the rich cultural traditions dating back to prehistoric times. Its unequivocal identification is extremely important in many branches of science and trades including archeology, paleontology, chemistry and finally mineralogical and gemological societies. Current methods of modification of natural succinite are more and more sophisticated making the identification of natural Baltic amber often challenging. In article the systematic analytical approach for identification of natural and modified under different conditions succinite, using mid-infrared spectroscopy (transmission, Drifts and ATR techniques) is presented. The correlation between spectral characteristics and properties of succinite is discussed pointing that the understanding of the nature of changes is the key of identification of this precious material.
Identifying Neck and Back Pain in Administrative Data: Defining the right cohort
Siroka, Andrew M.; Shane, Andrea C.; Trafton, Jodie A.; Wagner, Todd H.
2017-01-01
Structured Abstract Study design We reviewed existing methods for identifying patients with neck and back pain in administrative data. We compared these methods using data from the Department of Veterans Affairs. Objective To answer the following questions: 1) what diagnosis codes should be used to identify patients with neck and back pain in administrative data; 2) because the majority of complaints are characterized as non-specific or mechanical, what diagnosis codes should be used to identify patients with non-specific or mechanical problems in administrative data; and 3) what procedure and surgical codes should be used to identify patients who have undergone a surgical procedure on the neck or back. Summary of background data Musculoskeletal neck and back pain are pervasive problems, associated with chronic pain, disability, and high rates of healthcare utilization. Administrative data have been widely used in formative research which has largely relied on the original work of Volinn, Cherkin, Deyo and Einstadter and the Back Pain Patient Outcomes Assessment Team first published in 1992. Significant variation in reports of incidence, prevalence, and morbidity associated with these problems may be due to non standard or conflicting methods to define study cohorts. Methods A literature review produced seven methods for identifying neck and back pain in administrative data. These code lists were used to search VA data for patients with back and neck problems, and to further categorize each case by spinal segment involved, as non- specific/mechanical and as surgical or not. Results There is considerable overlap in most algorithms. However, gaps remain. Conclusions Gaps are evident in existing methods and a new framework to identify patients with neck and back pain in administrative data is proposed. PMID:22127268
2011-01-01
Background Low back disorders are a common and costly cause of pain and activity limitation in adults. Few treatment options have demonstrated clinically meaningful benefits apart from advice which is recommended in all international guidelines. Clinical heterogeneity of participants in clinical trials is hypothesised as reducing the likelihood of demonstrating treatment effects, and sampling of more homogenous subgroups is recommended. We propose five subgroups that allow the delivery of specific physiotherapy treatment targeting the pathoanatomical, neurophysiological and psychosocial components of low back disorders. The aim of this article is to describe the methodology of a randomised controlled trial comparing specific physiotherapy treatment to advice for people classified into five subacute low back disorder subgroups. Methods/Design A multi-centre parallel group randomised controlled trial is proposed. A minimum of 250 participants with subacute (6 weeks to 6 months) low back pain and/or referred leg pain will be classified into one of five subgroups and then randomly allocated to receive either physiotherapy advice (2 sessions over 10 weeks) or specific physiotherapy treatment (10 sessions over 10 weeks) tailored according to the subgroup of the participant. Outcomes will be assessed at 5 weeks, 10 weeks, 6 months and 12 months following randomisation. Primary outcomes will be activity limitation measured with a modified Oswestry Disability Index as well as leg and back pain intensity measured on separate 0-10 Numerical Rating Scales. Secondary outcomes will include a 7-point global rating of change scale, satisfaction with physiotherapy treatment, satisfaction with treatment results, the Sciatica Frequency and Bothersomeness Scale, quality of life (EuroQol-5D), interference with work, and psychosocial risk factors (Orebro Musculoskeletal Pain Questionnaire). Adverse events and co-interventions will also be measured. Data will be analysed according to intention to treat principles, using linear mixed models for continuous outcomes, Mann Whitney U tests for ordinal outcomes, and Chi-square, risk ratios and risk differences for dichotomous outcomes. Discussion This trial will determine the difference in outcomes between specific physiotherapy treatment tailored to each of the five subgroups versus advice which is recommended in guidelines as a suitable treatment for most people with a low back disorder. Trial registration Australia and New Zealand Clinical Trials Register (ANZCTR): ACTRN12609000834257. PMID:21599941
Towngas Lantau link beach approach, Hong Kong and China Gas Co. Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callnon, D.P.; Bertolucci, L.
1997-07-01
Horizontal directional drilling (HDD) laid dual, 12-in. OD, natural gas pipelines beneath a critical sea wall on Lantau island, Hong Kong New Territories. This was part of a 30-mile gas pipeline crossing under the South China Sea associated with the Towngas Lantau construction project for Hong Kong`s new Chep Lap Kok International Airport. During a twenty-one day project, Cherrington Corp. drilled and forward-reamed two, 20-in., 1,294-ft. holes to pull back the twin pipelines. The project was completed during typhoon weather, strong currents and logistical problems associated with operation in a remote uninhabited area. The successful installation of the twin gasmore » lines was the result of proper hole design, high-quality surveying techniques and innovative directional drilling methods. Each hole exited approximately 90-ft. from the pre-installed product pipe in the sea floor trench. A 20-in. reamer with bull-nose and rear stabilizer was used to open both holes from 9 to 20-inches.« less
Informatics methodologies for evaluation research in the practice setting.
Grant, A; Buteau, M; Richards, Y; Delisle, E; Laplante, P; Niyonsenga, T; Xhignesse, M
1998-06-01
A continuing challenge in health informatics and health evaluation is to enable access to the practice of health care so that the determinants of successful care and good health outcomes can be measured, evaluated and analysed. Furthermore the results of the analysis should be available to the health care practitioner or to the patient as might be appropriate, so that he or she can use this information for continual improvement of practice and optimisation of outcomes. In this paper we review two experiences, one in primary care, the FAMUS project, and the other in hospital care, the Autocontrol project. Each project demonstrates an informatics approach for evaluation research in the clinical setting and indicates ways in which useful information can be obtained which with appropriate feed-back and education can be used towards the achievement of better health. Emphasis is given to data collection methods compatible with practice and to high quality information feedback, particularly in the team context, to enable the formulation of strategies for practice improvement.
O'Keeffe, Mary; Dankaerts, Wim; O'Sullivan, Peter; O'Sullivan, Leonard; O'Sullivan, Kieran
2013-01-01
No study has examined the effectiveness of prescribing seating modifications according to the individual clinical presentation of people with low back pain (LBP). A dynamic, forward-inclined chair ('Back App') can reduce seated paraspinal muscle activation among pain-free participants. This study examined 21 participants whose LBP was specifically aggravated by prolonged sitting and was eased by standing. Low back discomfort (LBD) and overall body discomfort (OBD) were assessed every 15 min while participants sat for 1 h on both the dynamic, forward-inclined chair and a standard office chair. LBD increased significantly more (p = 0.005) on the standard office chair, with no significant difference (p = 0.178) in OBD between the chairs. The results demonstrate that, in a specific flexion-related subgroup of people with LBP, increased LBD during sitting can be minimised through modifying chair design. Mechanisms that minimise seated discomfort may be of relevance in LBP management, as part of a biopsychosocial management plan. This study examined low back discomfort (LBD) during a typing task among people with low back pain (LBP). Sitting on a dynamic, forward-inclined chair resulted in less seated LBD than sitting on a standard office chair. Further research is required to examine the long-term effectiveness of ergonomics interventions in LBP.
ERIC Educational Resources Information Center
Furstenberg, Gilberte; English, Kathryn
2016-01-01
Two of the original authors of "Giving a Virtual Voice to the Silent Language of Culture: The Cultura Project", published in "Language Learning & Technology" in 2001, look back on the origin of the Cultura project, its goals, and the approach and materials used. Their commentary then focuses on the features and the…
Code of Federal Regulations, 2011 CFR
2011-01-01
...' discretion. (iii) Risk factors and other monitoring—(A) Risk factors; other monitoring. A Bank's written monitoring policies shall take into account risk factors such as the amount of AHP subsidy in the project... reasonable risk-based sampling plan to review the back-up project documentation. (2) Reliance on long-term...