Gale, Heather I; Sharatz, Steven M; Taphey, Mayureewan; Bradley, William F; Nimkin, Katherine; Gee, Michael S
2017-09-01
Assessment for active Crohn disease by CT enterography and MR enterography relies on identifying mural and perienteric imaging features. To evaluate the performance of established imaging features of active Crohn disease in children and adolescents on CT and MR enterography compared with histological reference. We included patients ages 18 years and younger who underwent either CT or MR enterography from 2007 to 2014 and had endoscopic biopsy within 28 days of imaging. Two pediatric radiologists blinded to the histological results reviewed imaging studies and scored the bowel for the presence or absence of mural features (wall thickening >3 mm, mural hyperenhancement) and perienteric features (mesenteric hypervascularity, edema, fibrofatty proliferation and lymphadenopathy) of active disease. We performed univariate analysis and multivariate logistic regression to compare imaging features with histological reference. We evaluated 452 bowel segments (135 from CT enterography, 317 from MR enterography) from 84 patients. Mural imaging features had the highest association with active inflammation both for MR enterography (wall thickening had 80% accuracy, 69% sensitivity and 91% specificity; mural hyperenhancement had 78%, 53% and 96%, respectively) and CT enterography (wall thickening had 84% accuracy, 72% sensitivity and 91% specificity; mural hyperenhancement had 76%, 51% and 91%, respectively), with perienteric imaging features performing significantly worse on MR enterography relative to CT enterography (P < 0.001). Mural features are predictors of active inflammation for both CT and MR enterography, while perienteric features can be distinguished better on CT enterography compared with MR enterography. This likely reflects the increased conspicuity of the mesentery on CT enterography and suggests that mural features are the most reliable imaging features of active Crohn disease in children and adolescents.
Seastedt, Kenneth P; Trencheva, Koiana; Michelassi, Fabrizio; Alsaleh, Doaa; Milsom, Jeffrey W; Sonoda, Toyooki; Lee, Sang W; Nandakumar, Govind
2014-12-01
CT enterography and magnetic resonance enterography have emerged as first-line imaging technologies for the evaluation of the gastrointestinal tract in Crohn's disease. The purpose of this work was to evaluate the accuracy of these imaging modalities to identify Crohn's disease lesions preoperatively. This was a retrospective chart review. The study was conducted at a single institution. Seventy-six patients with Crohn's disease with preoperative CT enterography and/or magnetic resonance enterography were included in the study. The number of stenoses, fistulas, and abscesses on CT enterography and/or magnetic resonance enterography before surgery were compared with operative findings. Forty patients (53%) were women, 46 (60%) underwent surgery for recurrent Crohn's disease, and 46 (57%) had previous abdominal surgery. Thirty-six (47%) had a preoperative CT enterography and 43 (57%) had a preoperative magnetic resonance enterography. CT enterography sensitivity was 75% for stenosis and 50% for fistula. MRE sensitivity was 68% for stenosis and 60% for fistula. The negative predictive values of CT enterography and magnetic resonance enterography for stenosis were very low (54% and 65%) and were 85% and 81% for fistula. CT enterography had 76% accuracy for stenosis and 79% for fistula; magnetic resonance enterography had 78% accuracy for stenosis and 85% for fistula. Both were accurate for abscess. False-negative rates for CT enterography were 50% for fistula and 25% for stenosis. False-negative rates for magnetic resonance enterography were 40% for fistula and 32% for stenosis. Unexpected intraoperative findings led to modification of the planned surgical procedure in 20 patients (26%). This study was limited by its small sample size, its retrospective nature, and that some studies were performed at outside institutions. CT enterography and magnetic resonance enterography in patients with Crohn's disease were accurate for the identification of abscesses but not for fistulas or stenoses. Surgeons should search for additional lesions intraoperatively. Patients should be appropriately counseled regarding the need for unexpected interventions (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A162).
Hong, Seong Sook; Kim, Ah Young; Kwon, Seok Beom; Kim, Pyo Nyun; Lee, Moon-Gyu; Ha, Hyun Kwon
2010-10-01
To evaluate the feasibility of 3D CT enterography using oral gastrografin in patients with small bowel obstruction (SBO), focusing on improving diagnostic performance as compared with the use of axial CT imagings and fluoroscopic findings. For a 10-month period, 18 patients with known SBO detected clinically and radiologically were enrolled. In all patients, gastrografin was ingested prior to CT enterography. Twelve patients underwent a fluoroscopic examination. Images were randomly assessed for confidence for the level, for the cause of SBO, and for the assessment of the interpretability of each image by two gastrointestinal radiologists. The results were considered statistically significant using the Wilcoxon rank sum test. All patients (100%) well tolerated the administration of oral gastrografin. The use of 3D CT enterography significantly improved diagnostic confidence for the interpretation of the level, cause of SBO, and the assessment of the interpretability of each image as compared with the use of axial CT images (P < 0.05). 3D CT enterography was superior as compared to fluoroscopic examination (P < 0.05). The use of gastrografin for 3D CT enterography is a safe and feasible technique for precise evaluation of known or suspected SBO.
... equipped to deal with them. Advancements in CT technology now allow CT enterography to be performed with even lower radiation doses. Because children are more sensitive to radiation, they should have ...
He, Bosheng; Gu, Jinhua; Huang, Sheng; Gao, Xuesong; Fan, Jinhe; Sheng, Meihong; Wang, Lin; Gong, Shenchu
2017-02-01
This study was performed to evaluate the diagnostic performance of multi-slice CT angiography combined with enterography in determining the cause and location of obstruction as well as intestinal ischaemia in patients with small bowel obstruction (SBO). This study retrospectively summarized the image data of 57 SBO patients who received both multi-slice CT angiography and enterography examination between December 2012 and May 2013. The CT diagnoses of SBO and intestinal ischaemia were correlated with the findings at surgery or digital subtraction angiography, which were set as standard references. Multi-slice CT angiography and enterography indicated that the cause of SBO in three patients was misjudged, suggesting a diagnostic accuracy of 94.7%. In one patient the level of obstruction was incorrect, demonstrating a diagnostic accuracy of 98.2%. Based on the results of the receiver operating characteristic (ROC) curve analysis, the diagnostic criterion for ischaemic SBO was at least two of the four CT signs (circumferential bowel wall thickening, reduced enhancement of the intestinal wall, mesenteric oedema and mesenteric vascular engorgement). The criterion yielded a sensitivity of 94.4%, a specificity of 92.3%, a positive predicted value of 85.0% and a negative predicted value of 97.3%, and the area under curve (AUC) was 0.92 (95% CI, 0.85-0.99). Multi-slice CT angiography and enterography have high diagnostic value in identifying the cause and site of SBO. In addition, the suggested diagnostic criterion using CT signs is helpful for diagnosing intestinal ischaemia in SBO patients. © 2016 The Royal Australian and New Zealand College of Radiologists.
Pediatric Small Bowel Crohn Disease: Correlation of US and MR Enterography
Smith, Ethan A.; Sanchez, Ramon J.; DiPietro, Michael A.; DeMatos-Maillard, Vera; Strouse, Peter J.; Darge, Kassa
2015-01-01
Small bowel Crohn disease is commonly diagnosed during the pediatric period, and recent investigations show that its incidence is increasing in this age group. Diagnosis and follow-up of this condition are commonly based on a combination of patient history and physical examination, disease activity surveys, laboratory assessment, and endoscopy with biopsy, but imaging also plays a central role. Ultrasonography (US) is an underutilized well-tolerated imaging modality for screening and follow-up of small bowel Crohn disease in children and adolescents. US has numerous advantages over computed tomographic (CT) enterography and magnetic resonance (MR) enterography, including low cost and no required use of oral or intravenous contrast material. US also has the potential to provide images with higher spatial resolution than those obtained at CT enterography and MR enterography, allows faster examination than does MR enterography, does not involve ionizing radiation, and does not require sedation or general anesthesia. US accurately depicts small bowel and mesenteric changes related to pediatric Crohn disease, and US findings show a high correlation with MR imaging findings in this patient population. ©RSNA, 2015 PMID:25839736
Small bowel adenocarcinoma in Crohn disease: CT-enterography features with pathological correlation.
Soyer, Philippe; Hristova, Lora; Boudghène, Frank; Hoeffel, Christine; Dray, Xavier; Laurent, Valérie; Fishman, Elliot K; Boudiaf, Mourad
2012-06-01
The aim of this study was to analyze the clinical, pathological, and CT-enterography findings of small bowel adenocarcinomas in Crohn disease patients. Clinical, histopathological, and imaging findings were retrospectively evaluated in seven Crohn disease patients with small bowel adenocarcinoma. CT-enterography examinations were reviewed for morphologic features and location of tumor, presence of stratification, luminal stenosis, proximal dilatation, adjacent lymph nodes, and correlated with findings at histological examination. The tumor was located in the terminal (n = 6) or distal (n = 1) ileum. On CT-enterography, the tumor was visible in five patients, whereas two patients had no visible tumor. Four different patterns were individualized including small bowel mass (n = 2), long stenosis with heterogeneous submucosal layer (n = 2), short and severe stenosis with proximal small bowel dilatation (n = 2), and sacculated small bowel loop with irregular and asymmetric circumferential thickening (n = 1). Stratification, fat stranding, and comb sign were present in two, two, and one patients, respectively. Identification of a mass being clearly visible suggests strongly the presence of small bowel adenocarcinoma in Crohn disease patients but adenocarcinoma may be completely indistinguishable from benign fibrotic or acute inflammatory stricture. Knowledge of these findings is critical to help suggest the diagnosis of this rare but severe complication of Crohn disease.
... causes, such as infection. You may also undergo flexible sigmoidoscopy, colonoscopy, body CT, body MRI, MR enterography, upper GI, small ... Flexible sigmoidoscopy , performed by inserting a sigmoidoscope (a flexible tube ... can also sometimes be seen. Body CT scan , a special type of x-ray ...
Masselli, Gabriele; Mastroiacovo, Ilaria; De Marco, Emidio; Francione, Giulia; Casciani, Emanuele; Polettini, Elisabetta; Gualdi, Gianfranco
2016-01-01
Crohn’s disease affects more than 500000 individuals in the United States, and about 25% of cases are diagnosed during the pediatric period. Imaging of the bowel has undergone dramatic changes in the past two decades. The endoscopy with biopsy is generally considered the diagnostic reference standard, this combination can evaluates only the mucosa, not inflammation or fibrosis in the mucosa. Actually, the only modalities that can visualize submucosal tissues throughout the small bowel are the computed tomography (CT) enterography (CTE) with the magnetic resonance enterography (MRE). CT generally is highly utilized, but there is growing concern over ionizing radiation and cancer risk; it is a very important aspect to keep in consideration in pediatric patients. In contrast to CTE, MRE does not subject patients to ionizing radiation and can be used to detect detailed morphologic information and functional data of bowel disease, to monitor the effects of medical therapy more accurately, to detect residual active disease even in patients showing apparent clinical resolution and to guide treatment more accurately. PMID:27551337
Gandhi, Namita S; Baker, Mark E; Goenka, Ajit H; Bullen, Jennifer A; Obuchowski, Nancy A; Remer, Erick M; Coppa, Christopher P; Einstein, David; Feldman, Myra K; Kanmaniraja, Devaraju; Purysko, Andrei S; Vahdat, Noushin; Primak, Andrew N; Karim, Wadih; Herts, Brian R
2016-08-01
Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.
CT enterography: Mannitol versus VoLumen.
Wong, Jessica; Moore, Helen; Roger, Mark; McKee, Chris
2016-10-01
Several different neutral oral contrast agents have been trialled in magnetic resonance and CT enterography (CTE). In the Auckland region, Mannitol 2.5% and VoLumen are both used in CTE. This study compares the performance of these two neutral oral contrast agents in CTE. Computed tomography enterography data were collected from 25 consecutive studies that used either Mannitol or VoLumen in 2014. All images were reviewed by three radiologists blinded to the type of oral contrast. Each quadrant was assessed for maximum distension, proportion of bowel loops distended, presence of inhomogeneous content and bowel wall visibility. Assessment also included whether the contrast agent reached the caecum and an overall subjective quality assessment. Patients were invited to answer a questionnaire regarding tolerability of the preparations. Mannitol achieves better wall visibility in the right upper quadrant, left upper quadrant and left lower quadrant (P < 0.01). Overall differences in study quality favours Mannitol (P < 0.01) with 48% of the Mannitol studies being considered excellent compared with 4% of the VoLumen studies. There was no difference in maximal distension or proportion of loops distended. Mannitol in CTE achieves studies of a better quality than and is a viable alternative to VoLumen. © 2016 The Royal Australian and New Zealand College of Radiologists.
Lim, Bee Kuan; Bux, Shaik Ismail; Rahmat, Kartini; Lam, Sze Yin; Liew, Yew Wai
2012-11-01
We compared the effectiveness of different types of non-commercial neutral oral contrast agents for bowel distension and mural visualisation in computed tomographic (CT) enterography. 90 consecutive patients from a group of 108 were randomly assigned to receive water (n = 30), 3.8% milk (n = 30) or 0.1% gastrografin (n = 30) as oral contrast agent. The results were independently reviewed by two radiologists who were blinded to the contrast agents used. The degree of bowel distension was qualitatively scored on a four-point scale. The discrimination of bowel loops, mural visualisation and visualisation of mucosal folds were evaluated on a 'yes' or 'no' basis. Side effects of the various agents were also recorded. 3.8% milk was significantly superior to water for bowel distension (jejunum, ileum and terminal ileum), discrimination of bowel loops (jejunum and ileum), mural visualisation and visualisation of mucosal folds (ileum and terminal ileum). It was also significantly superior to 0.1% gastrografin for bowel distension, discrimination of bowel loops, mural visualisation and visualisation of mucosal folds (jejunum, ileum and terminal ileum). However, 10% of patients who received 3.8% milk reported immediate post-test diarrhoea. No side effects were documented for patients who received water and 0.1% gastrografin. 3.8% milk is an effective and superior neutral oral contrast agent for the assessment of the jejunum, ileum and terminal ileum in CT enterography. However, further studies are needed to explore other suitable oral contrast agents for CT enterography in lactose- or cow's milk-intolerant patients.
Villanueva Campos, A M; Tardáguila de la Fuente, G; Utrera Pérez, E; Jurado Basildo, C; Mera Fernández, D; Martínez Rodríguez, C
To analyze whether there are significant differences in the objective quantitative parameters obtained in the postprocessing of dual-energy CT enterography studies between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. This retrospective study analyzed 33 patients (16 men and 17 women; mean age 54 years) with known Crohn's disease who underwent CT enterography on a dual-energy scanner with oral sorbitol and intravenous contrast material in the portal phase. Images obtained with dual energy were postprocessed to obtain color maps (iodine maps). For each patient, regions of interest were traced on these color maps and the density of iodine (mg/ml) and the fat fraction (%) were calculated for the wall of a pathologic bowel segment with radiologic signs of Crohn's disease and for the wall of a healthy bowel segment; the differences in these parameters between the two segments were analyzed. The density of iodine was lower in the radiologically normal segments than in the pathologic segments [1.8 ± 0.4mg/ml vs. 3.7 ± 0.9mg/ml; p<0.05]. The fat fraction was higher in the radiologically normal segments than in the pathologic segments [32.42% ± 6.5 vs. 22.23% ± 9.4; p<0.05]. There are significant differences in the iodine density and fat fraction between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
ACR Appropriateness Criteria Crohn Disease.
Kim, David H; Carucci, Laura R; Baker, Mark E; Cash, Brooks D; Dillman, Jonathan R; Feig, Barry W; Fowler, Kathryn J; Gage, Kenneth L; Noto, Richard B; Smith, Martin P; Yaghmai, Vahid; Yee, Judy; Lalani, Tasneem
2015-10-01
Crohn disease is a chronic inflammatory disorder involving the gastrointestinal tract, characterized by episodic flares and times of remission. Underlying structural damage occurs progressively, with recurrent bouts of inflammation. The diagnosis and management of this disease process is dependent on several clinical, laboratory, imaging, endoscopic, and histologic factors. In recent years, with the maturation of CT enterography, and MR enterography, imaging has played an increasingly important role in relation to Crohn Disease. In addition to these specialized examination modalities, ultrasound and routine CT have potential uses. Fluoroscopy, radiography, and nuclear medicine may be less beneficial depending on the clinical scenario. The imaging modality best suited to evaluating this disease may change, depending on the target population, severity of presentation, and specific clinical situation. This document presents seven clinical scenarios (variants) in both the adult and pediatric populations and rates the appropriateness of the available imaging options. They are summarized in a consolidated table, and the underlying rationale and supporting literature are presented in the accompanying narrative. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every three years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Computed Tomography Enterography for Evaluation of Inflammatory Bowel Disease
Park, Min Jung
2013-01-01
Computed tomography enterography (CTE) has become a main modality for the evaluation of inflammatory bowel disease (IBD). It simultaneously offers visualization of the small bowel and extraintestinal status, which is helpful for diagnosing IBD. Crohn disease has long segmental enhancing wall thickening related with the eccentric longitudinal distribution. In addition, mural stratification, fibrofatty proliferation, positive comb sign by increased mesenteric vascularity and internal/perianal fistula are characteristics of Crohn disease and can be identified on CTE. Short segmental inflammatory wall thickening and the central low attenuated lymph nodes are favorable CT finding of intestinal tuberculosis. A geographic, relatively large, and deep penetrating ulcer with bowel wall thickening and mural hyperenhancement in ileocecal area are characteristics of intestinal Behcet disease. Each of CTE findings for the IBDs is helpful for differential diagnosis. The main disadvantage of this technique is the requisite radiation exposure of patients, particularly in young patients. However, recent development of advanced CT techniques is promising for radiation dose reduction without compromising diagnostic image quality. PMID:23964329
CT enterography for Crohn's disease: accurate preoperative diagnostic imaging.
Vogel, Jon; da Luz Moreira, Andre; Baker, Mark; Hammel, Jeffery; Einstein, David; Stocchi, Luca; Fazio, Victor
2007-11-01
CT enterography (CTE) is a technique that provides detailed images of the small bowel by using a low Hounsfield unit oral contrast media. This study was designed to correlate CTE findings with operative findings in patients with Crohn's disease. We performed a retrospective study of all patients with Crohn's disease of the small bowel or colon, who had CTE and subsequent small bowel or colon surgery within three months after the CT examination. CTE findings of stricture, fistula, inflammatory mass, abscess, and combinations of these abnormalities were compared with operative findings. Specialist radiologists and fellowship-trained colorectal surgeons participated in the study. The Fisher's exact test or chi-squared tests were used with respect to categorical data, and the Wilcoxon's rank-sum test was used for quantitative data. In 36 patients, the presence or absence of stricture, fistula, abscess, or inflammatory mass was correctly determined by CTE in 100, 94, 100, and 97 percent, respectively. The accuracy for stricture or fistula number was 83 and 86 percent, respectively. There were nine patients with multiple disease phenotypes identified on CTE of which eight were confirmed at surgery. CTE overestimated or underestimated the extent of disease in 11 patients (31 percent). CTE is an accurate preoperative diagnostic imaging study for small-bowel Crohn's disease. The ability of this imaging study to detect both luminal and extraluminal pathology is a distinct advantage of CTE compared with small-bowel contrast studies.
Seo, Nieun; Park, Seong Ho; Kim, Kyung-Jo; Kang, Bo-Kyeong; Lee, Yedaun; Yang, Suk-Kyun; Ye, Byong Duk; Park, Sang Hyoung; Kim, So Yeon; Baek, Seunghee; Han, Kyunghwa; Ha, Hyun Kwon
2016-03-01
To determine whether magnetic resonance (MR) enterography performed with diffusion-weighted imaging (DWI) without intravenous contrast material is noninferior to contrast material-enhanced (CE) MR enterography for the evaluation of small-bowel inflammation in Crohn disease. Institutional review board approval and informed consent were obtained for this prospective noninferiority study. Fifty consecutive adults suspected of having Crohn disease underwent clinical assessment, MR enterography, and ileocolonoscopy within 1 week. MR enterography included conventional imaging and DWI (b = 900 sec/mm(2)). In 44 patients with Crohn disease, 171 small-bowel segments that were generally well distended and showed a wide range of findings, from normalcy to severe inflammation (34 men, 10 women; mean age ± standard deviation, 26.9 years ± 6.1), were selected for analysis. Image sets consisting of (a) T2-weighted sequences with DWI and (b) T2-weighted sequences with CE T1-weighted sequences were reviewed by using a crossover design with blinding and randomization. Statistical analyses included noninferiority testing regarding proportional agreement between DWI and CE MR enterography for the identification of bowel inflammation with a noninferiority margin of 80%, correlation between DWI and CE MR enterography scores of bowel inflammation severity, and comparison of accuracy between DWI and CE MR enterography for the diagnosis of terminal ileal inflammation by using endoscopic findings as the reference standard. The agreement between DWI and CE MR enterography for the identification of bowel inflammation was 91.8% (157 of 171 segments; one-sided 95% confidence interval: ≥88.4%). The correlation coefficient between DWI and CE MR enterography scores was 0.937 (P < .001). DWI and CE MR enterography did not differ significantly regarding the sensitivity and specificity for the diagnosis of terminal ileal inflammation (P > .999). DWI and CE MR enterography concurred in the diagnosis of penetrating complications in five of eight segments. DWI MR enterography was noninferior to CE MR enterography for the evaluation of inflammation in Crohn disease in generally well-distended small bowel, except for the diagnosis of penetration.
Shenoy-Bhangle, Anuradha S; Nimkin, Katherine; Aranson, Thomas; Gee, Michael S
2016-01-01
MR enterography is increasingly utilized for noninvasive evaluation of disease activity in young patients with Crohn disease and has great impact on clinical management. Diffusion-weighted imaging (DWI) is a rapid MR imaging technique that measures molecular diffusion of water and is sensitive to the inflammatory process; however, its value to MR enterography has not been rigorously evaluated. To determine whether the addition of DWI to MR enterography is helpful in evaluating Crohn disease activity in young patients when compared to a histological reference. In this single-institution retrospective study, we searched an imaging database for the period January 2010 to December 2012 to identify patients age 19 years and younger who had MR enterography with diffusion-weighted imaging (DWI). We used an electronic medical record search to identify those who had MR enterography and colonoscopy performed within 28 days of each other. All MR enterography scans were performed on a 1.5-T or 3-T clinical MR scanner with phased-array torso coil configuration using standard pulse sequences as well as axial DWI with b values of 50, 400 and 800. Bowel segments were evaluated for disease activity based on standard MR enterography sequences; in addition, segmental apparent diffusion coefficient (ADC) values were calculated based on DWI. Histological reference for disease activity was based on assessment for mucosal inflammatory changes on endoscopic biopsy. MR enterography and DWI evaluation were performed in a blinded fashion with respect to histological results. We included imaging of 78 bowel segments from 27 patients (mean age 14.5 ± 3.02 years) with known Crohn disease in the study. The mean ADC for bowel segments with active disease was 1.56 ± 0.7 × 10(3) mm(2)/s compared with 2.58 ± 1.4 × 10(3) mm(2)/s for segments without active disease, a difference that was statistically significant (P < 0.01, Student's t-test). Using a threshold value of 2.0 × 10(3) mm(2)/s, DWI demonstrated lower accuracy (64.1%) but higher sensitivity (78.8%) for detecting active disease compared with standard MR enterography (69.2% and 54.6%, respectively). Combining DWI with MR enterography, using DWI as the initial screen and MR enterography afterward to reduce false negativity, led to a significant increase in accuracy (76.9%; P = 0.03, McNemar's test) compared with either imaging technique alone. Although DWI does not perform as well as standard MR enterography for detection of active Crohn disease, the combination of DWI and MR enterography increases imaging accuracy for determining disease activity compared with either technique alone. These results indicate that DWI adds value to MR enterography and supports the incorporation of DWI into MR enterography protocols for evaluation of Crohn disease in young patients.
Imširović, Bilal; Zerem, Enver; Efendić, Alma; Mekić Abazović, Alma; Zerem, Omar; Djedović, Muhamed
2018-08-01
Aim To determine capabilities and potential of contrast enhanced magnetic resonance imaging (MRI) enterography in order to establish the diagnosis and to evaluate severity and activity of intestinal inflammation. Methods Fifty-five patients with suspicion for presence of Crohn's disease were evaluated. All patients underwent contrast enhanced MRI enterography and diffusion weighted imaging (DWI), and subsequently endoscopic examination or surgical treatment. Four parameters were analysed: thickening of the bowel wall, and presence of abscess, fistula and lymphadenopathy. Results Comparing results of DWI and contrast enhanced MRI enterography a significant difference between results given through diffusion and histopathological test was found, e.g. a significant difference between results obtained through diffusion and MRI enterography was found. MRI enterography sensitiveness for bowel wall thickening was 97.7% and specificity 70%, whilst DWI sensitivity for bowel wall thickening was 84% and specificity 100%. The diagnostics of abscess and fistula showed no significant difference between DWI and MRI, while in lymphadenopathy significant difference between contrast enhanced MRI enterography and DWI was found. Conclusion Contrast enhanced MRI enterography in combination with DWI allows for excellent evaluation of disease activity, but also problems or complications following it. The examination can be repeated, controlled, and it can contribute to monitoring of patients with this disease. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
Kim, Jin Sil; Jang, Hye Young; Park, Seong Ho; Kim, Kyung-Jo; Han, Kyunghwa; Yang, Suk-Kyun; Ye, Byong Duk; Park, Sang Hyoung; Lee, Jong Seok; Kim, Hyun Jin
2017-05-01
The purpose of this article is to appraise the use of the MR index of activity (MaRIA) score in evaluating Crohn disease (CD) on present-day MR enterography images, with an emphasis on determining the modifying roles of DWI and the effects of different contrast enhancement phases. Fifty patients prospectively underwent MR enterography, including DWI and enteric and portal phase scans, and ileocolonoscopy with segmental CD endoscopic index of severity (CDEIS) scoring within a week. Thirty-nine terminal ilea and 40 right-sided colons (mean [± SD] segmental CDEIS score, 14.3 ± 12.1) from 42 patients with CD (mean age, 27 ± 6.2 years) were finally analyzed by three independent readers. Original and modified (ulcer replaced with DWI grade) MaRIA scores were compared regarding their correlation with segmental CDEIS score, accuracy in diagnosing active (segmental CDEIS score ≥ 3) and severe (segmental CDEIS score ≥ 12) inflammation, and interobserver reproducibility. The primary analysis used portal phase data, and the agreement between portal and enteric phase scores was analyzed. MaRIA and modified MaRIA scores correlated similarly with CDEIS scores (r = 0.737 and 0.742; p = 0.387) and did not significantly differ in terms of AUC values for the diagnosis of active (0.909 and 0.903; p = 0.571) or severe (0.907 and 0.892; p = 0.443) inflammation. The intraclass correlation coefficient was significantly higher for modified MaRIA than for MaRIA (0.845 and 0.701; p < 0.001). The mean difference between portal and enteric phase scores (i.e., portal minus enteric) was 0.33-0.36 score points for individual readers, and the Bland-Altman repeatability coefficient was 0.9-1.42 score points. Interobserver reproducibility in evaluating the severity of bowel inflammation in CD using the MaRIA score can be improved by modification with DWI. MaRIA scoring provides steady results across enteric and portal phases.
DWI at MR Enterography for Evaluating Bowel Inflammation in Crohn Disease.
Park, Seong Ho
2016-07-01
The purpose of this article is to provide a comprehensive review regarding DWI enterography used for evaluating Crohn disease and to summarize the relevant evidence. Active bowel inflammation in Crohn disease causes restricted diffusion on MR enterography with DWI. Enterographic DWI to evaluate Crohn disease is increasingly drawing attention for both academic research and clinical practice and has shown potential as a quantitative tool for assessing bowel inflammation. DWI enterography also has multiple unresolved issues and limitations.
Pous-Serrano, S; Frasson, M; Palasí Giménez, R; Sanchez-Jordá, G; Pamies-Guilabert, J; Llavador Ros, M; Nos Mateu, P; Garcia-Granero, E
2017-05-01
To assess the accuracy of magnetic resonance enterography in predicting the extension, location and characteristics of the small bowel segments affected by Crohn's disease. This is a prospective study including a consecutive series of 38 patients with Crohn's disease of the small bowel who underwent surgery at a specialized colorectal unit of a tertiary hospital. Preoperative magnetic resonance enterography was performed in all patients, following a homogeneous protocol, within the 3 months prior to surgery. A thorough exploration of the small bowel was performed during the surgical procedure; calibration spheres were used according to the discretion of the surgeon. The accuracy of magnetic resonance enterography in detecting areas affected by Crohn's disease in the small bowel was assessed. The findings of magnetic resonance enterography were compared with surgical and pathological findings. Thirty-eight patients with 81 lesions were included in the study. During surgery, 12 lesions (14.8%) that were not described on magnetic resonance enterography were found. Seven of these were detected exclusively by the use of calibration spheres, passing unnoticed at surgical exploration. Magnetic resonance enterography had 90% accuracy in detecting the location of the stenosis (75.0% sensitivity, 95.7% specificity). Magnetic resonance enterography did not precisely diagnose the presence of an inflammatory phlegmon (accuracy 46.2%), but it was more accurate in detecting abscesses or fistulas (accuracy 89.9% and 98.6%, respectively). Magnetic resonance enterography is a useful tool in the preoperative assessment of patients with Crohn's disease. However, a thorough intra-operative exploration of the entire small bowel is still necessary. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
Endoscopic Skipping of the Terminal Ileum in Pediatric Crohn Disease.
Mansuri, Ishrat; Fletcher, Joel G; Bruining, David H; Kolbe, Amy B; Fidler, Jeff L; Samuel, Sunil; Tung, Jeanne
2017-06-01
Pediatric small-bowel (SB) Crohn disease (CD) may be missed if the terminal ileum (TI) appears normal at endoscopy and SB imaging is not performed. We sought to estimate the prevalence and clinical characteristics of pediatric patients with CD and endoscopic skipping of the TI-that is, pediatric patients with active SB or upper gut inflammation and an endoscopically normal TI. This retrospective study included pediatric patients with CD who underwent both CT enterography (CTE) or MR enterography (MRE) and ileocolonoscopy within a 30-day period between July 2004 and April 2014. The physician global assessment was used as the reference standard for SB CD activity. Radiologists reviewed the CTE and MRE studies for inflammatory parameters; severity, length, and multifocality of SB inflammation; and the presence of penetrating complications. Of 170 patients who underwent ileal intubation, the TI was macroscopically normal or showed nonspecific inflammation in 73 patients (43%). Nearly half (36/73, 49%) of the patients with normal or nonspecific findings at ileocolonoscopy had radiologically active disease with a median length of SB involvement of 20 cm (range, 1 to > 100 cm). Seventeen (47%) of these patients had multifocal SB involvement and five (14%) had penetrating complications. Overall, endoscopic TI skipping was present in 43 (59%) patients with normal or nonspecific ileocolonoscopic findings: 20 with histologic inflammation (17 with positive imaging findings), 14 with inflammation at imaging only, and nine with proximal disease (upper gut, jejunum, or proximal ileum). There were no significant differences in the clinical parameters of the patients with and those without endoscopic TI skipping. Ileocolonoscopy may miss SB CD in pediatric patients that is due to isolated histologic, intramural, or proximal inflammation. Enterography is complementary to ileocolonoscopy in the evaluation of pediatric CD.
Magnetic resonance enterography in pediatric celiac disease.
Koc, Gonca; Doganay, Selim; Sevinc, Eylem; Deniz, Kemal; Chavhan, Govind; Gorkem, Sureyya B; Karacabey, Neslihan; Dogan, Mehmet S; Coskun, Abdulhakim; Aslan, Duran
To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Thirty-one pediatric patients (mean age 11.7±3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. The mean duration of the disease was 5.6±1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2±66.6RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Magnetic Resonance Enterography in Crohn׳s Disease.
Westerland, Olwen; Griffin, Nyree
2016-08-01
Over the past decade, magnetic resonance (MR) enterography has become established as the first-line imaging test for patients with Crohn׳s disease. This article reviews the role of MR enterography in assessing the extent and activity of Crohn׳s disease at baseline and on treatment follow-up. It discusses the role of diffusion-weighted imaging, and the recent introduction of MR scoring systems to facilitate noninvasive objective assessment of disease activity and cumulative bowel damage. Copyright © 2016 Elsevier Inc. All rights reserved.
Maccioni, Francesca; Al Ansari, Najwa; Mazzamurro, Fabrizio; Civitelli, Fortunata; Viola, Franca; Cucchiara, Salvatore; Catalano, Carlo
2014-11-01
The purpose of this article is to prospectively determine the accuracy of MR enterography in detecting Crohn disease lesions from the jejunum to the anorectal region in pediatric patients, in comparison with main reference investigations. Fifty consecutive children with known Crohn disease underwent MR enterography with oral contrast agent and gadolinium-chelate intravenous injection. Two radiologists detected and localized lesions by dividing the bowel into nine segments (450 analyzed segments in 50 patients). Ileocolonoscopy, barium studies, intestinal ultrasound, and capsule endoscopy were considered as first- and second-level reference examinations and were performed within 15 days of MR enterography. MR enterography detected lesions in 164 of 450 segments, with 155 true-positive and nine false-positive findings; overall sensitivity, specificity, and positive and negative predictive values for small- and large-bowel lesions were 94.5%, 97%, 94.5%, and 97%, respectively (ĸ = 0.93; 95% CI, 0.89-0.97). Sensitivity and specificity values were 88% and 97%, respectively, for the jejunum, 100% and 97% for the proximal-to-mid ileum, 100% and 100% for the distal ileum, 93% and 100% for the cecum, 70% and 97% for the ascending colon, 80% and 100% for the transverse colon, 100% and 92% for the descending colon, 96% and 90% for the sigmoid colon, and 96% and 88% for the rectum. From jejunum to rectum, the AUC value ranged between 0.916 (jejunum) and 1.00 (distal ileum). Perianal fistulas were diagnosed in 15 patients, and other complications were found in 13 patients. MR enterography showed an accuracy comparable to that of reference investigations, for both small- and large-bowel lesions. Because MR enterography is safer and more comprehensive than the reference examinations, it should be considered the primary examination for detecting Crohn disease lesions in children.
Collagenous sprue cross-sectional imaging: a comparative blinded study.
Al-Bawardy, Badr; Sheedy, Shannon P; Herberts, Michelle B; Murray, Joseph A; Rubio-Tapia, Alberto; Rajan, Elizabeth; Bruining, David H; Hansel, Stephanie L; Barlow, John M; Fletcher, Joel G; Fidler, Jeff L
2017-02-01
Collagenous sprue (CS) is a rare enteropathy characterized by villous atrophy and a thickened subepithelial collagen band. The aim of this study is to describe the cross-sectional imaging findings of CS. A case-control, retrospective study with cases of all CS patients from January 2000 to 2015 was performed. Inclusion criteria were (1) Histopathologic diagnosis and (2) Imaging with computed tomography abdomen/pelvis (CT A/P), CT enterography (CTE), or magnetic resonance enterography within 6 months of small bowel (SB) biopsy. Control subjects were irritable bowel syndrome (IBS) patients who underwent CTE. Imaging studies were examined by two GI radiologists, blinded to patient data. 108 patients (54 CS; 54 IBS) were included. Mean age was 56.7 ± 16.5 years, and 68% were female (72% in CS group vs. 63% in IBS group; p = 0.3). CS patients were significantly older (67 ± 12 vs. 47 ± 15 year; p < 0.001) and more likely to be on angiotensin receptor blockers (41% vs. 6%; p < 0.001) as compared to the IBS group. Compared to IBS, CS patients were more likely to have mesenteric lymph node (LN) prominence (56% vs. 15%; p < 0.001), jejunoileal fold pattern reversal (46% vs. 6%; p < 0.001), SB dilation (28% vs. 0%; p < 0.001), SB conformational change (28% vs. 6%; p = 0.002), SB wall thickening (13% vs. 2%; p = 0.03), and ulcerative jejunoileitis (4% vs. 0%; p = 0.01). Radiologists suspected malabsorption in 72% in the CS group and 2% in the IBS group (p < 0.001). Imaging findings suggestive of mucosal malabsorption are commonly demonstrated in CS.
Iwańczak, Barbara M; Nienartowicz, Ewa; Krzesiek, Elżbieta
2016-01-01
In pediatric patients Crohn's disease most commonly involves the colon and the ileocecal part of the intestine. MR enterography, a new method of small bowel imaging with magnetic resonance, has been introduced in the last decade. The aim of this study was to assess the usefulness of the MR enterography in the diagnosis of small bowel lesions in children with Crohn's disease. The study included 37 children (18 girls and 19 boys) aged from 5.5 to 18 years (average age, 13.3), diagnosed with Crohn's disease according to the Porto criteria. The disease duration ranged from 1 month to 12 years, on average 3 years. MR eterography was performed according to the Giles et al. protocol. The obtained results were compared with the location and the manifestation of the disease according to the Paris classification. In 13 children (35.1%), the disease began prior to 10 years of age, and in the remaining 24 children (64.9%) between 10 and 17 years of age. The gastrointestinal endoscopy confirmed Crohn's disease in the colon (45.9%) and in the colon and ileum (27.1%). An incomplete colonoscopy examination which did not reveal the location of the disease was conducted in 7 children (18.9%). A comparison of the location of Crohn's disease with the location of lesions in the small bowel as indicated by MR enterography revealed that the most common changes can be found in the final part of ileum, in ileum, and in 4 children in jejunum. MR enterography demonstrated, that 16 children (43.2%) had inflammation, 7 children (18.9%) stenosis, and 14 children (37.8%) had no lesions at all. MR enterography is a non-invasive and safe procedure well tolerated by children that allows the visualization of lesions in the small bowel in children with Crohn's disease.
Accumulation of mesalazine pills in the medium ileum in a patient with Crohn´s disease.
Martínez Huertas, Carmen; Garcia-Villanova Ruiz, Paloma; Pozo Sánchez, José; Dávila Arias, Cristina
2017-03-01
Crohn´s disease is an inflammatory disease that can involve any portion of the gastrointestinal tract, although terminal ileum is the most commonly affected portion. It is characterized by a transmural and discontinuous distribution pattern, with alternating periods of active disease and remission. We present the case of a 23-year-old patient diagnosed with Crohn´s disease, in treatment with extended release Mesalazine and corticoids. The CT Enterography showed activity signs and a great dilatation of medium ileum with lots of Mesalazine pills accumulated inside. Pill accumulation occurred because of stenosis, which did not let the pills at this level progress to distal ileum, and be absorbed.
MRI in patients with inflammatory bowel disease
Gee, Michael S.; Harisinghani, Mukesh G.
2011-01-01
Inflammatory bowel disease (IBD) affects approximately 1.4 million people in North America and, because of its typical early age of onset and episodic disease course, IBD patients often undergo numerous imaging studies over the course of their lifetimes. CT has become the standard imaging modality for assessment of IBD patients because of its widespread availability, rapid image acquisition, and ability to evaluate intraluminal and extraluminal disease. However, repetitive CT imaging has been associated with a significant ionizing radiation risk to patients, making MRI an appealing alternative IBD imaging modality. Pelvic MRI is currently the imaging gold standard for detecting perianal disease, while recent studies indicate that MRI bowel-directed techniques (enteroclysis, enterography, colonography) can accurately evaluate bowel inflammation in IBD. With recent technical innovations leading to faster and higher resolution body MRI, the role of MRI in IBD evaluation is likely to continue to expand. Future applications include surveillance imaging, detection of mural fibrosis, and early assessment of therapy response. PMID:21512607
Adaptive nonlocal means filtering based on local noise level for CT denoising
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhoubo; Trzasko, Joshua D.; Lake, David S.
2014-01-15
Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analyticalmore » noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.« less
MR enterography in children: Principles, technique, and clinical applications.
Chavhan, Govind B; Babyn, Paul S; Walters, Thomas
2013-04-01
MR enterography is a constantly advancing technique for assessment of bowel with newer technology and sequences. It is being increasingly used for the assessment of inflammatory bowel disease and has almost replaced barium follow through examinations in many institutions. Its lack of radiation makes it an attractive alternative for bowel evaluation in children. It has been proved to be highly sensitive in the detection of Crohn disease in adults and children. It is also superior to barium studies in showing extra-enteric findings and detecting complications such as fistulas and abscesses. Even though at present it is almost exclusively used for the evaluation of inflammatory bowel disease, it has the potential to be used in other conditions affecting the bowel. The principles, MR enterography technique pertinent to children, and its utility in the assessment of Crohn disease in children are discussed in this review.
Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet
2017-04-01
Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.
Lee, Seul Bi; Kim, Seung Ho; Son, Jung Hee; Baik, Ji Yeon
2017-12-01
To compare small bowel distension and bowel wall visualization among three different patients' positions (supine, sitting and right decubitus) during administration of oral contrast media in preparation for CT enterography (CTE). A total of 150 consecutive patients (104 males and 46 females; mean age 34.6 years, range 15-78 years) who were scheduled to undergo CTE were recruited. Patients were randomly allocated into the three position groups during oral contrast media administration, and there were 50 patients in each group. Two blinded radiologists independently scored the luminal distension and visualization of the bowel wall using a continuous 5-point scale (1: worst and 5: best) at the jejunum and ileum. The Mann-Whitney U test was used to evaluate differences between any two groups among the three positions for bowel distension and wall visualization. For ileal distension, the supine and sitting positions performed better than the right decubitus position [for reader 1, mean: 3.4/3.2/2.9 (hereafter, supine/sitting/right decubitus in order), p = 0.002/0.033; for reader 2, 3.3/3.0/2.6, p < 0.001/0.027]. However, there was no significant difference among the three groups for jejunal distension (for reader 1, 2.4/2.3/2.2; for reader 2, 2.4/2.4/2.2, p > 0.05, respectively). For bowel wall visualization, the supine and sitting positions were superior to the right decubitus position for the ileum when scored by one reader (4.0/3.8/3.4, p = 0.001/0.015). Supine and sitting positions during the administration of oral contrast media provided better ileal distension than the right decubitus position in obtaining CTE. Advances in knowledge: The performance of CTE largely depends on adequate luminal distension and wall visualization. As the terminal ileum is the predominant site of small bowel pathology for inflammatory bowel disease, the supine or sitting position would be preferable for patients who are suspected of having small bowel pathology.
Bruining, David H; Zimmermann, Ellen M; Loftus, Edward V; Sandborn, William J; Sauer, Cary G; Strong, Scott A
2018-03-01
Computed tomography and magnetic resonance enterography have become routine small bowel imaging tests to evaluate patients with established or suspected Crohn's disease, but the interpretation and use of these imaging modalities can vary widely. A shared understanding of imaging findings, nomenclature, and utilization will improve the utility of these imaging techniques to guide treatment options, as well as assess for treatment response and complications. Representatives from the Society of Abdominal Radiology Crohn's Disease-Focused Panel, the Society of Pediatric Radiology, the American Gastroenterological Association, and other experts, systematically evaluated evidence for imaging findings associated with small bowel Crohn's disease enteric inflammation and established recommendations for the evaluation, interpretation, and use of computed tomography and magnetic resonance enterography in small bowel Crohn's disease. This work makes recommendations for imaging findings that indicate small bowel Crohn's disease, how inflammatory small bowel Crohn's disease and its complications should be described, elucidates potential extra-enteric findings that may be seen at imaging, and recommends that cross-sectional enterography should be performed at diagnosis of Crohn's disease and considered for small bowel Crohn's disease monitoring paradigms. A useful morphologic construct describing how imaging findings evolve with disease progression and response is described, and standard impressions for radiologic reports that convey meaningful information to gastroenterologists and surgeons are presented. © 2018, RSNA, AGA Institute, and Society of Abdominal Radiology This article is being published jointly in Radiology and Gastroenterology.
Bruining, David H; Zimmermann, Ellen M; Loftus, Edward V; Sandborn, William J; Sauer, Cary G; Strong, Scott A
2018-03-01
Computed tomography and magnetic resonance enterography have become routine small bowel imaging tests to evaluate patients with established or suspected Crohn's disease, but the interpretation and use of these imaging modalities can vary widely. A shared understanding of imaging findings, nomenclature, and utilization will improve the utility of these imaging techniques to guide treatment options, as well as assess for treatment response and complications. Representatives from the Society of Abdominal Radiology Crohn's Disease-Focused Panel, the Society of Pediatric Radiology, the American Gastroenterological Association, and other experts, systematically evaluated evidence for imaging findings associated with small bowel Crohn's disease enteric inflammation and established recommendations for the evaluation, interpretation, and use of computed tomography and magnetic resonance enterography in small bowel Crohn's disease. This work makes recommendations for imaging findings that indicate small bowel Crohn's disease, how inflammatory small bowel Crohn's disease and its complications should be described, elucidates potential extra-enteric findings that may be seen at imaging, and recommends that cross-sectional enterography should be performed at diagnosis of Crohn's disease and considered for small bowel Crohn's disease monitoring paradigms. A useful morphologic construct describing how imaging findings evolve with disease progression and response is described, and standard impressions for radiologic reports that convey meaningful information to gastroenterologists and surgeons are presented. Copyright © 2018 AGA Institute, RSNA, and Society of Abdominal Radiology. Published by Elsevier Inc. All rights reserved.
Feng, Cui; Zhu, Di; Zou, Xianlun; Li, Anqin; Hu, Xuemei; Li, Zhen; Hu, Daoyu
2018-03-01
To investigate the subjective and quantitative image quality and radiation exposure of CT enterography (CTE) examination performed at low tube voltage and low concentration of contrast agent with adaptive statistical iterative reconstruction (ASIR) algorithm, compared with conventional CTE.One hundred thirty-seven patients with suspected or proved gastrointestinal diseases underwent contrast enhanced CTE in a multidetector computed tomography (MDCT) scanner. All cases were assigned to 2 groups. Group A (n = 79) underwent CT with low tube voltage based on patient body mass index (BMI) (BMI < 23 kg/m, 80 kVp; BMI ≥ 23 kg/m, 100 kVp) and low concentration of contrast agent (270 mg I/mL), the images were reconstructed with standard filtered back projection (FBP) algorithm and 50% ASIR algorithm. Group B (n = 58) underwent conventional CTE with 120 kVp and 350 mg I/mL contrast agent, the images were reconstructed with FBP algorithm. The computed tomography dose index volume (CTDIvol), dose length product (DLP), effective dose (ED), and total iodine dosage were calculated and compared. The CT values, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of the normal bowel wall, gastrointestinal lesions, and mesenteric vessels were assessed and compared. The subjective image quality was assessed independently and blindly by 2 radiologists using a 5-point Likert scale.The differences of values for CTDIvol (8.64 ± 2.72 vs 11.55 ± 3.95, P < .001), ED (6.34 ± 2.24 vs 8.52 ± 3.02, P < .001), and DLP (422.6 ± 149.40 vs 568.30 ± 213.90, P < .001) were significant between group A and group B, with a reduction of 25.2%, 25.7%, and 25.7% in group A, respectively. The total iodine dosage in group A was reduced by 26.1%. The subjective image quality did not differ between the 2 groups (P > .05) and all image quality scores were greater than or equal to 3 (moderate). Fifty percent ASIR-A group images provided lower image noise, but similar or higher quantitative image quality in comparison with FBP-B group images.Compared with the conventional protocol, CTE performed at low tube voltage, low concentration of contrast agent with 50% ASIR algorithm produce a diagnostically acceptable image quality with a mean ED of 6.34 mSv and a total iodine dose reduction of 26.1%.
Welch, B T; Coelho Prabhu, N; Walkoff, L; Trenkner, S W
2016-12-01
A 71-year-old male with 50-year history of Crohn's disease was evaluated for acute onset of dizziness and slurred speech. Blood ethanol levels were elevated despite abstinence from alcohol for over 30 years. CT enterography demonstrated massive dilation of the small bowel with anastomotic stricture. Auto-brewery syndrome may be considered in a patient with chronic obstruction or hypomotility presenting with elevated serum ethanol levels in the setting of high carbohydrate intake. Although treatment algorithms lack validation, judicious use of antibiotic therapy, carbohydrate control, and short courses of antifungal therapy have all been reported in the literature. Importantly, clinical consideration of 'auto-brewery' should be undertaken with substantial caution, given the lack of validated mechanisms linking endogenous ethanol production to peripheral blood ethanol. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Stieger-Vanegas, Susanne M; Cebra, Christopher K
2013-01-15
To assess the feasibility and usefulness of CT enterography to evaluate the gastrointestinal tract in clinically normal llamas and alpacas. Prospective observational study. 7 clinically normal alpacas and 8 clinically normal llamas. The imaging protocol included orogastric administration of iodinated contrast material mixed with water. Three hours later, helical CT scanning was performed of the entire abdomen with transverse and multiplanar sagittal and dorsal projections before and after IV iodinated contrast agent injection. Both oral and IV contrast agents were well tolerated, and no adverse reactions were observed. Transverse images depicted the gastrointestinal tract and pancreas in the short axis; however, dorsal and sagittal projections aided in localizing and differentiating the various gastrointestinal segments, including the pancreas. In all camelids, the wall of the gastrointestinal tract was well differentiated. In all but 2 camelids, all gastrointestinal segments were well visualized and differentiated. In those 2 animals, the cecum was difficult to identify. Good distention of the small intestine was achieved by use of the oral contrast agent. The dorsal projections were useful to identify the pancreas in its entire length. The present study supplied new information about gastrointestinal wall thickness, intestinal diameter, and location of the pancreas and ileocecocolic junction in alpacas and llamas. Multiplanar contrast-enhanced CT was useful to reveal the various segments of the gastrointestinal tract, pancreas, and abdominal lymph nodes. The shorter time delay before imaging, compared with the delay with conventional barium studies, makes this technique complementary or superior to conventional radiographic or ultrasonographic studies for evaluation of the gastrointestinal tract.
... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...
[Magnetic resonance enterography: technique and indications. Findings in Crohn's disease].
Torregrosa, A; Pallardó, Y; Hinojosa, J; Insa, S; Molina, R
2013-09-01
Radiology with oral contrast, or enteroclysis, have traditionally been the techniques of choice in the examination of the small intestine, due to the excellent visualisation of the mucosal pattern. However, the absence of extra-luminal information and the use of ionising radiation have replaced these examinations with sectional techniques which enable the abdominal cavity to be viewed with good resolution. Magnetic resonance enterography is a simple technique, with no ionising radiation, provided quality images, distends the intestinal lumen well by the administration of non-reabsorbable oral substances, minimises peristalsis, and establishes a protocol which includes sequences with intravenous contrast. These properties can be used in patients with Crohn's disease, achieving good diagnostic precision in the assessment of activity and monitoring of treatment, in intestinal obstruction, in the suspicion of small intestine tumours, and in paediatric patients due to it being harmless. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
MR Enterography of Inflammatory Bowel Disease with Endoscopic Correlation.
Kaushal, Pankaj; Somwaru, Alexander S; Charabaty, Aline; Levy, Angela D
2017-01-01
Crohn disease (CD) and ulcerative colitis (UC) are the two main forms of idiopathic inflammatory bowel disease (IBD). CD is a transmural chronic inflammatory disorder that can affect any part of the gastrointestinal tract in a discontinuous distribution. UC is a mucosal and submucosal chronic inflammatory disease that typically originates in the rectum and may extend proximally in a continuous manner. In treating patients with CD and UC, clinicians rely heavily on accurate diagnoses and disease staging. Magnetic resonance (MR) enterography used in conjunction with endoscopy and histopathologic analysis can help accurately diagnose and manage disease in the majority of patients. Endoscopy is more sensitive for detection of the early-manifesting mucosal abnormalities seen with IBD and enables histopathologic sampling. MR enterography yields more insightful information about the pathologic changes seen deep to the mucosal layer of the gastrointestinal tract wall and to those portions of the small bowel that are not accessible endoscopically. CD can be classified into active inflammatory, fistulizing and perforating, fibrostenotic, and reparative and regenerative phases of disease. Although CD has a progressive course, there is no stepwise progression between these disease phases, and various phases may exist at the same time. The endoscopic and MR enterographic features of UC can be broadly divided into two categories: acute phase and subacute-chronic phase. Understanding the endoscopic features of IBD and the pathologic processes that cause the MR enterographic findings of IBD can help improve the accuracy of disease characterization and thus optimize the medication and surgical therapies for these patients. © RSNA, 2016.
Barber, Joy L; Zambrano-Perez, Alexsandra; Olsen, Øystein E; Kiparissi, Fevronia; Baycheva, Mila; Knaflez, Daniela; Shah, Neil; Watson, Tom A
2018-06-01
Magnetic resonance enterography (MRE) is the current gold standard for imaging in inflammatory bowel disease, but ultrasound (US) is a potential alternative. To determine whether US is as good as MRE for the detecting inflamed bowel, using a combined consensus score as the reference standard. We conducted a retrospective cohort study in children and adolescents <18 years with inflammatory bowel disease (IBD) at a tertiary and quaternary centre. We included children who underwent MRE and US within 4 weeks. We scored MRE using the London score and US using a score adapted from the METRIC (MR Enterography or Ultrasound in Crohn's Disease) trial. Four gastroenterologists assessed an independent clinical consensus score. A combined consensus score using the imaging and clinical scores was agreed upon and used as the reference standard to compare MRE with US. We included 53 children. At a whole-patient level, MRE scores were 2% higher than US scores. We used Lin coefficient to assess inter-observer variability. The repeatability of MRE scores was poor (Lin 0.6). Agreement for US scoring was substantial (Lin 0.95). There was a significant positive correlation between MRE and clinical consensus scores (Spearman's rho = 0.598, P=0.0053) and US and clinical consensus scores (Spearman's rho = 0.657, P=0.0016). US detects as much clinically significant bowel disease as MRE. It is possible that MRE overestimates the presence of disease when using a scoring system. This study demonstrates the feasibility of using a clinical consensus reference standard in paediatric IBD imaging studies.
Improving Efficiency Using Time-Driven Activity-Based Costing Methodology.
Tibor, Laura C; Schultz, Stacy R; Menaker, Ronald; Weber, Bradley D; Ness, Jay; Smith, Paula; Young, Phillip M
2017-03-01
The aim of this study was to increase efficiency in MR enterography using a time-driven activity-based costing methodology. In February 2015, a multidisciplinary team was formed to identify the personnel, equipment, space, and supply costs of providing outpatient MR enterography. The team mapped the current state, completed observations, performed timings, and calculated costs associated with each element of the process. The team used Pareto charts to understand the highest cost and most time-consuming activities, brainstormed opportunities, and assessed impact. Plan-do-study-act cycles were developed to test the changes, and run charts were used to monitor progress. The process changes consisted of revising the workflow associated with the preparation and administration of glucagon, with completed implementation in November 2015. The time-driven activity-based costing methodology allowed the radiology department to develop a process to more accurately identify the costs of providing MR enterography. The primary process modification was reassigning responsibility for the administration of glucagon from nurses to technologists. After implementation, the improvements demonstrated success by reducing non-value-added steps and cost by 13%, staff time by 16%, and patient process time by 17%. The saved process time was used to augment existing examination time slots to more accurately accommodate the entire enterographic examination. Anecdotal comments were captured to validate improved staff satisfaction within the multidisciplinary team. This process provided a successful outcome to address daily workflow frustrations that could not previously be improved. A multidisciplinary team was necessary to achieve success, in addition to the use of a structured problem-solving approach. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Hsu, Wei-Fan; Tsang, Yuk-Ming; Teng, Chung-Jen; Chung, Chen-Shuan
2015-01-21
Obscure gastrointestinal bleeding is an uncommonly encountered and difficult-to-treat clinical problem in gastroenterology, but advancements in endoscopic and radiologic imaging modalities allow for greater accuracy in diagnosing obscure gastrointestinal bleeding. Ectopic varices account for less than 5% of all variceal bleeding cases, and jejunal variceal bleeding due to extrahepatic portal hypertension is rare. We present a 47-year-old man suffering from obscure gastrointestinal bleeding. Computed tomography of the abdomen revealed multiple vascular tufts around the proximal jejunum but no evidence of cirrhosis, and a visible hypodense filling defect suggestive of thrombus was visible in the superior mesenteric vein. Enteroscopy revealed several serpiginous varices in the proximal jejunum. Serologic data disclosed protein C deficiency (33.6%). The patient was successfully treated by therapeutic balloon-assisted enteroscopy and long-term anticoagulant therapy, which is normally contraindicated in patients with gastrointestinal bleeding. Diagnostic modalities for obscure gastrointestinal bleeding, such as capsule endoscopy, computed tomography enterography, magnetic resonance enterography, and enteroscopy, were also reviewed in this article.
Nuzzo, Alexandre; Zappa, Magaly; Cazals-Hatem, Dominique; Bouhnik, Yoram
2016-09-01
Mesenteric panniculitis (MP) is mostly an associated sign of an intra-abdominal or systemic inflammatory primary disease. Nevertheless, etiological and differential diagnosis of idiopathic MP can be challenging when an associate primary cause is not in the foreground. We report here the case of an isolated small bowel Crohn's disease, long time considered as idiopathic MP. This patient presented to our department with a 10-year history of acute abdominal symptoms evolving with flare-up and remission. A diagnosis of idiopathic MP was made based on compatible CT-scan features along with normal laboratory tests and upper and lower bowel endoscopies. As symptoms recurred, a steroid course was proposed which dramatically improved his condition for years. Finally, an explorative laparoscopy was performed because of concern of malignancy when he returned to our unit with a steroid refractory flare-up and weight loss, along with MP nodes growing up to 10 mm. Crohn's disease was eventually diagnosed, based on histopathological middle-gut bowel resection and numerous granulomas in mesenteric nodes without necrosis. This case emphasizes the importance of excluding inflammatory intestinal lesions before making the diagnosis of idiopathic MP (fecal calprotectin, magnetic resonance enterography, wireless capsule endoscopy).
Thomassin-Naggara, I; Bendifallah, S; Rousset, P; Bazot, M; Ballester, M; Darai, E
2018-03-01
Diagnostic performance of MR imaging for the diagnosis of pelvic endometriosis are good. Even if some differences of performances exists according the location considered, the risk of misdiagnosis is lower than 10% for trained teams (NP2). The performance of pelvic MR imaging and surgery are quite similar to diagnose endometrioma (sensitivity and specificity>90%). A negative pelvic MR imaging allows to exclude deep pelvic endometriosis with a performance similar to surgery but a positive MR imaging is less accurate than surgery because of a high number of false positives (23%). Pelvic MR imaging is more sensitive and less specific than ultrasonography for the diagnosis of uterosacral ligament, vagina or recto vaginal septum (NP2). Pelvic ultrasonography is more sensitive than pelvic MR imaging for the diagnosis of colorectal location (NP3). Pelvic MR imaging is a reproducible technique for the diagnosis of pelvic endometriosis (NP3). Regarding, quality criteria of pelvic MR imaging, no data are enough to recommend a specific MR unit, digestive preparation, or a specific moment during the menstrual cycle to realize the examination. Vaginal and/or rectal opacification are options. Most of studies are based a protocol including 3D T2W and 3DT1W sequences. Gadolinium injection is useful to characterize a complex adnexal mass. In clinical routine, slices crossing the kidneys are useful to evaluate the presence of pyelo calic distension. ColoCT is an accurate technique to diagnose pelvic digestive endometriosis (rectosigmoide and iléocaecal) (NP3). Copyright © 2018 Elsevier Masson SAS. All rights reserved.
ACR Appropriateness Criteria® Nonvariceal Upper Gastrointestinal Bleeding.
Singh-Bhinder, Nimarta; Kim, David H; Holly, Brian P; Johnson, Pamela T; Hanley, Michael; Carucci, Laura R; Cash, Brooks D; Chandra, Ankur; Gage, Kenneth L; Lambert, Drew L; Levy, Angela D; Oliva, Isabel B; Peterson, Christine M; Strax, Richard; Rybicki, Frank J; Dill, Karin E
2017-05-01
Upper gastrointestinal bleeding (UGIB) remains a significant cause of morbidity and mortality with mortality rates as high as 14%. This document addresses the indications for imaging UGIB that is nonvariceal and unrelated to portal hypertension. The four variants are derived with respect to upper endoscopy. For the first three, it is presumed that upper endoscopy has been performed, with three potential initial outcomes: endoscopy reveals arterial bleeding source, endoscopy confirms UGIB without a clear source, and negative endoscopy. The fourth variant, "postsurgical and traumatic causes of UGIB; endoscopy contraindicated" is considered separately because upper endoscopy is not performed. When endoscopy identifies the presence and location of bleeding but bleeding cannot be controlled endoscopically, catheter-based arteriography with treatment is an appropriate next study. CT angiography (CTA) is comparable with angiography as a diagnostic next step. If endoscopy demonstrates a bleed but the endoscopist cannot identify the bleeding source, angiography or CTA can be typically performed and both are considered appropriate. In the event of an obscure UGIB, angiography and CTA have been shown to be equivalent in identifying the bleeding source; CT enterography may be an alternative to CTA to find an intermittent bleeding source. In the postoperative or traumatic setting when endoscopy is contraindicated, primary angiography, CTA, and CT with intravenous contrast are considered appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Mennecke, Angelika; Svergun, Stanislav; Scholz, Bernhard; Royalty, Kevin; Dörfler, Arnd; Struffert, Tobias
2017-01-01
Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. • After coiling subarachnoid haemorrhage, metal artefacts seriously reduce FD-CT image quality. • This new metal artefact reduction algorithm is feasible for flat-detector CT. • After coiling, MAR is necessary for diagnostic quality of affected slices. • Slice-wise Pearson correlation is introduced to evaluate improvement of MAR in future studies. • Metal-unaffected parts of image are not modified by this MAR algorithm.
Scarfone, Christopher; Lavely, William C; Cmelak, Anthony J; Delbeke, Dominique; Martin, William H; Billheimer, Dean; Hallahan, Dennis E
2004-04-01
The aim of this investigation was to evaluate the influence and accuracy of (18)F-FDG PET in target volume definition as a complementary modality to CT for patients with head and neck cancer (HNC) using dedicated PET and CT scanners. Six HNC patients were custom fitted with head and neck and upper body immobilization devices, and conventional radiotherapy CT simulation was performed together with (18)F-FDG PET imaging. Gross target volume (GTV) and pathologic nodal volumes were first defined in the conventional manner based on CT. A segmentation and surface-rendering registration technique was then used to coregister the (18)F-FDG PET and CT planning image datasets. (18)F-FDG PET GTVs were determined and displayed simultaneously with the CT contours. CT GTVs were then modified based on the PET data to form final PET/CT treatment volumes. Five-field intensity-modulated radiation therapy (IMRT) was then used to demonstrate dose targeting to the CT GTV or the PET/CT GTV. One patient was PET-negative after induction chemotherapy. The CT GTV was modified in all remaining patients based on (18)F-FDG PET data. The resulting PET/CT GTV was larger than the original CT volume by an average of 15%. In 5 cases, (18)F-FDG PET identified active lymph nodes that corresponded to lymph nodes contoured on CT. The pathologically enlarged CT lymph nodes were modified to create final lymph node volumes in 3 of 5 cases. In 1 of 6 patients, (18)F-FDG-avid lymph nodes were not identified as pathologic on CT. In 2 of 6 patients, registration of the independently acquired PET and CT data using segmentation and surface rendering resulted in a suboptimal alignment and, therefore, had to be repeated. Radiotherapy planning using IMRT demonstrated the capability of this technique to target anatomic or anatomic/physiologic target volumes. In this manner, metabolically active sites can be intensified to greater daily doses. Inclusion of (18)F-FDG PET data resulted in modified target volumes in radiotherapy planning for HNC. PET and CT data acquired on separate, dedicated scanners may be coregistered for therapy planning; however, dual-acquisition PET/CT systems may be considered to reduce the need for reregistrations. It is possible to use IMRT to target dose to metabolically active sites based on coregistered PET/CT data.
A curly-tail modifier locus, mct1, on mouse chromosome 17
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letts, V.A.; Schork, N.J.; Frankel, W.N.
1995-10-10
The major gene for neural tube defects, ct, in the curly-tail (CT) mouse strain was mapped previously to mouse chromosome 4 by combining linkage data from several backcrosses. The penetrance of the neural tube trait, already incomplete in the CT strain, was further reduced in several of these backcrosses, suggesting the existence of recessive modifiers or strain-specific susceptibility alleles. Here we describe the mapping of a curly-tail modifier locus, mct1, to chromosome 17 in moderate and low penetrance crosses of CT with BALB/cByJ and Mus spretus. No effect of mct1 was seen in a higher penetrance cross with the BXD-8/Tymore » strain, confirming that ct is the major gene in the model. Homozygosity at both ct and mct1 loci was sufficient to account for all of the affected individuals in the BALB/cByJ cross and most of the affected individuals in the M. spretus cross and was the preferred model overall. No evidence was found for epistatic interaction between ct and mct1. 30 refs., 2 figs., 3 tabs.« less
Alshahrani, Lina Abdullah; Li, Xi; Luo, Hui; Yang, Linlin; Wang, Mengmeng; Yan, Songling; Liu, Peng; Yang, Yuqin; Li, Quanhua
2014-01-01
A glassy carbon electrode was modified with a copper(II) complex [Cu(Sal-β-Ala) (3,5-DMPz)2] (Sal = salicylaldehyde, β-Ala = β-alanine, 3,5-DMPz = 3,5-dimethylpyrazole) and single-walled carbon nanotubes (SWCNTs). The modified electrode was used to detect catechol (CT) and hydroquinone (HQ) and exhibited good electrocatalytic activities toward the oxidation of CT and HQ. The peak currents were linear with the CT and HQ concentrations over the range of 5–215 μmol·L−1 and 5–370 μmol·L−1 with corresponding detection limits of 3.5 μmol·L−1 and 1.46 μmol·L−1 (S/N = 3) respectively. Moreover, the modified electrode exhibited good sensitivity, stability and reproducibility for the determination of CT and HQ, indicating the promising applications of the modified electrode in real sample analysis. PMID:25429411
Reiter, Michael J; Nemesure, Allison; Madu, Ezemonye; Reagan, Lisa; Plank, April
2018-06-01
To describe the frequency, distribution and reporting patterns of incidental findings receiving the Lung-RADS S modifier on low-dose chest computed tomography (CT) among lung cancer screening participants. This retrospective investigation included 581 individuals who received baseline low-dose chest CT for lung cancer screening between October 2013 and June 2017 at a single center. Incidental findings resulting in assignment of Lung-RADS S modifier were recorded as were incidental abnormalities detailed within the body of the radiology report only. A subset of 60 randomly selected CTs was reviewed by a second (blinded) radiologist to evaluate inter-rater variability of Lung-RADS reporting. A total of 261 (45%) participants received the Lung-RADS S modifier on baseline CT with 369 incidental findings indicated as potentially clinically significant. Coronary artery calcification was most commonly reported, accounting for 182 of the 369 (49%) findings. An additional 141 incidentalomas of the same types as these 369 findings were described in reports but were not labelled with the S modifier. Therefore, as high as 69% (402 of 581) of participants could have received the S modifier if reporting was uniform. Inter-radiologist concordance of S modifier reporting in a subset of 60 participants was poor (42% agreement, kappa = 0.2). Incidental findings are commonly identified on chest CT for lung cancer screening, yet reporting of the S modifier within Lung-RADS is inconsistent. Specific guidelines are necessary to better define potentially clinically significant abnormalities and to improve reporting uniformity. Copyright © 2018 Elsevier B.V. All rights reserved.
Wesolowski, Jordan; Weber, Mary M.; Nawrotek, Agata; Dooley, Cheryl A.; Calderon, Mike; St. Croix, Claudette M.; Hackstadt, Ted; Cherfils, Jacqueline
2017-01-01
ABSTRACT The intracellular bacterium Chlamydia trachomatis develops in a parasitic compartment called the inclusion. Posttranslationally modified microtubules encase the inclusion, controlling the positioning of Golgi complex fragments around the inclusion. The molecular mechanisms by which Chlamydia coopts the host cytoskeleton and the Golgi complex to sustain its infectious compartment are unknown. Here, using a genetically modified Chlamydia strain, we discovered that both posttranslationally modified microtubules and Golgi complex positioning around the inclusion are controlled by the chlamydial inclusion protein CT813/CTL0184/InaC and host ARF GTPases. CT813 recruits ARF1 and ARF4 to the inclusion membrane, where they induce posttranslationally modified microtubules. Similarly, both ARF isoforms are required for the repositioning of Golgi complex fragments around the inclusion. We demonstrate that CT813 directly recruits ARF GTPases on the inclusion membrane and plays a pivotal role in their activation. Together, these results reveal that Chlamydia uses CT813 to hijack ARF GTPases to couple posttranslationally modified microtubules and Golgi complex repositioning at the inclusion. PMID:28465429
Vorst, Keith L; Todd, Ewen C D; Rysert, Elliot T
2004-10-01
Four sampling devices, a sterile environmental sponge (ES), a sterile cotton-tipped swab (CS), a sterile calcium alginate fiber-tipped swab (CAS), and a one-ply composite tissue (CT), were evaluated for quantitative recovery of Listeria monocytogenes from a food-grade stainless steel surface. Sterile 304-grade stainless steel plates (6 by 6 cm) were inoculated with approximately 106 CFU/cm2 L. monocytogenes strain Scott A and dried for 1 h. The ES and CT sampling devices were rehydrated in phosphate buffer solution. After plate swabbing, ES and CT were placed in 40 ml of phosphate buffer solution, stomached for 1 min and hand massaged for 30 s. Each CS and CAS device was rehydrated in 0.1% peptone before swabbing. After swabbing, CS and CAS were vortexed in 0.1% peptone for 1 min. Samples were spiral plated on modified Oxford agar with modified Oxford agar Rodac Contact plates used to recover any remaining cells from the stainless steel surface. Potential inhibition from CT was examined in both phosphate buffer solution and in a modified disc-diffusion assay. Recovery was 2.70, 1.34, and 0.62 log greater using CT compared with ES, CS, and CAS, respectively, with these differences statistically significant (P < 0.001) for ES and CT and for CAS, CS, and CT (P < 0.05). Rodac plates were typically overgrown following ES, positive after CS and CAS, and negative after CT sampling. CT was noninhibitory in both phosphate buffer solution and the modified disc-diffusion assay. Using scanning electron microscopy, Listeria cells were observed on stainless steel plates sampled with each sampling device except CT. The CT device, which is inexpensive and easy to use, represents a major improvement over other methods in quantifying L. monocytogenes on stainless steel surfaces and is likely applicable to enrichment of environmental samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeon, Chang Ho; Kim, Bohyoung; Gu, Bon Seung
2013-10-15
Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique wasmore » developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.« less
Primary small-bowel malignancy: update in tumor biology, markers, and management strategies.
Shenoy, Santosh
2014-12-01
Primary small-bowel malignancies (SBM) are rare tumors but their incidence is rising. An estimated 9160 new cases and 1210 deaths due to SBM may occur in the USA in 2014. We review advances made in tumor biology, immunohistochemistry, and discuss treatment strategies for these malignancies. Relevant articles from PubMed/Medline and Embase searches were collected using the phrases "small-bowel adenocarcinoma, gastrointestinal carcinoids, gastrointestinal stromal tumors, small-bowel leiomyosarcoma, and small-bowel lymphoma". Advances in imaging techniques such as wireless capsule endoscopy, CT and MRI enterography, and endoscopy (balloon enteroscopy) along with discovery of molecular markers such as c-kit and PDGFRA for GIST tumors have improved our ability to diagnose, localize, and treat these patients. Early detection and surgical resection offers the best chance for long-term survival in all tumors except bowel lymphoma where chemotherapy plays the main role. Adjuvant therapy with imatinib has improved overall survival for GIST tumors, somatostatin analogs have improved symptoms and also inhibited tumor growth and stabilized metastatic disease in carcinoid disease, but chemotherapy has not improved survival for adenocarcinoma. Recent advances in molecular characterization holds promise in novel targeted therapies. Currently ongoing trials are exploring efficacy of targeted therapies and role of adjuvant therapy for adenocarcinoma and results are awaited. Early detection and aggressive surgical therapy for all localized tumors and lymph node sampling particularly for adenocarcinoma remains the main treatment modality.
Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.
Parikh, A K; Shah, C C
2016-06-01
The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.
Riaz, Saima; Bashir, Humayun; Niazi, Imran Khalid; Butt, Sumera; Qamar, Faisal
2018-06-01
Mirels' scoring system quantifies the risk of sustaining a pathologic fracture in osseous metastases of weight bearing long bones. Conventional Mirels' scoring is based on radiographs. Our pilot study proposes Tc MDP bone SPECT-CT based modified Mirels' scoring system and its comparison with conventional Mirels' scoring. Cortical lysis was noted in 8(24%) by SPECT-CT versus 2 (6.3%) on X-rays. Additional SPECT-CT parameters were; circumferential involvement [1/4 (31%), 1/2 (3%), 3/4 (37.5%), 4/4 (28%)] and extra-osseous soft tissue [3%]. Our pilot study suggests the potential role of SPECT-CT in predicting risk of fracture in osseous metastases.
Adams, William M; Kleiter, Miriam M; Thrall, Donald E; Klauer, Julia M; Forrest, Lisa J; La Due, Tracy A; Havighurst, Thomas C
2009-01-01
Prognostic significance of tumor histology and four computed tomography (CT) staging methods was tested retrospectively in dogs from three treatment centers that underwent intent-to-cure-radiotherapy for intranasal neoplasia. Disease-free and overall survival times were available for 94 dogs. A grouping of anaplastic, squamous cell, and undifferentiated carcinomas had a significantly shorter median disease-free survival (4.4 mo) than a grouping of all sarcomas (10.6 months). Disease-free survivals were not significantly different, when all carcinomas were compared with all sarcomas. The published original and modified WHO staging methods did not significantly relate to either survival endpoint. A modified human maxillary tumor staging system previously applied to canine nasal tumors was prognostically significant for both survival endpoints; a further modified version of that CT-based staging system resulted in improved significance for both survival endpoints. Dogs with unilateral intranasal involvement without bone destruction beyond the turbinates on CT, had longest median survival (23.4 months); CT evidence of cribriform plate involvement was associated with shortest median survival (6.7 months). Combining CT and histology statistically improved prognostic significance for both survival endpoints over the proposed CT staging method alone. Significance was lost when CT stages were collapsed to < four categories or histopathology groupings were collapsed to < three categories.
Wesolowski, Jordan; Weber, Mary M; Nawrotek, Agata; Dooley, Cheryl A; Calderon, Mike; St Croix, Claudette M; Hackstadt, Ted; Cherfils, Jacqueline; Paumet, Fabienne
2017-05-02
The intracellular bacterium Chlamydia trachomatis develops in a parasitic compartment called the inclusion. Posttranslationally modified microtubules encase the inclusion, controlling the positioning of Golgi complex fragments around the inclusion. The molecular mechanisms by which Chlamydia coopts the host cytoskeleton and the Golgi complex to sustain its infectious compartment are unknown. Here, using a genetically modified Chlamydia strain, we discovered that both posttranslationally modified microtubules and Golgi complex positioning around the inclusion are controlled by the chlamydial inclusion protein CT813/CTL0184/InaC and host ARF GTPases. CT813 recruits ARF1 and ARF4 to the inclusion membrane, where they induce posttranslationally modified microtubules. Similarly, both ARF isoforms are required for the repositioning of Golgi complex fragments around the inclusion. We demonstrate that CT813 directly recruits ARF GTPases on the inclusion membrane and plays a pivotal role in their activation. Together, these results reveal that Chlamydia uses CT813 to hijack ARF GTPases to couple posttranslationally modified microtubules and Golgi complex repositioning at the inclusion. IMPORTANCE Chlamydia trachomatis is an important cause of morbidity and a significant economic burden in the world. However, how Chlamydia develops its intracellular compartment, the so-called inclusion, is poorly understood. Using genetically engineered Chlamydia mutants, we discovered that the effector protein CT813 recruits and activates host ADP-ribosylation factor 1 (ARF1) and ARF4 to regulate microtubules. In this context, CT813 acts as a molecular platform that induces the posttranslational modification of microtubules around the inclusion. These cages are then used to reposition the Golgi complex during infection and promote the development of the inclusion. This study provides the first evidence that ARF1 and ARF4 play critical roles in controlling posttranslationally modified microtubules around the inclusion and that Chlamydia trachomatis hijacks this novel function of ARF to reposition the Golgi complex. Copyright © 2017 Wesolowski et al.
Yang, Tsung-Shi; Liu, Tai-Ti; Lin, I-Hwa
2017-08-01
The aims of this research were to conjugate chitosan (CT) with stearic acid (SA) and gallic acid (GA), and apply the modified chitosan to stabilize labile aroma compounds such as allyl isothiocyanate (AITC) and limonene in oil-in-water emulsions. Generally, the antioxidant activity of CT-SA-GA increased as the GA content in the conjugate increased. In most assays, GA had a lower IC 50 value than that of CT-SA-GA; however, CT-SA-GA exhibited better performance than GA in the Fe 2+ -chelating activity. In accelerated tests (heating or illumination) for evaluating the chemical stability of AITC and limonene during storage, CT-SA and CT-SA-GA were used to prepare AITC and limonene O/W emulsions, respectively. Tween 80 and Span 80 (T-S-80), an emulsifier mixture, were used as a control in both emulsions for comparison. The results show that CT-SA or CT-SA-GA could protect AITC or limonene from degradation or oxidation more effectively than T-S-80. Copyright © 2017 Elsevier Ltd. All rights reserved.
Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.
Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A
2008-07-01
Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.
Jazwiecka-Koscielniak, Ewa; Kozakiewicz, Marcin
2014-10-01
Orbital reconstruction makes higher demands on symmetry and axial precision than other parts of the skull, because the position of the eye globe determines proper vision. The aim of this study is to evaluate titanium surface marking of polymers (UHMW-PE and PA6) to check implants position in CT examination and clinical application of such modified individual implant. One hundred and twenty-four polymer blocks were prepared. New method of ultrasounds welding to connect the titanium markers to the polymer surface was developed and tested. Titanium marked polymer blocks were examined by CT to evaluate the quality of the cover. Then, two modified UHMW-PE individual implants were applied clinically and implant position was checked by CT. The biggest titanium cover was in PA6 [25 ± 18% of processed surface] and for UHMW-PE [19 ± 12%] without significance [p = 0.14]. Both covers were visible in CT. Clinical application revealed proper reconstruction, uneventful post-operational outcome and well visible surface of the implants in CT. The conducted tests make it possible to determine the suitability of ultrasonic technology for the deposition of titanium markers in polymer. The clinical use of modified individual implants allows to confirm the correct position of the implants because they are accurate visible in CT. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves
PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. Aftermore » placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.« less
An approach for quantitative image quality analysis for CT
NASA Astrophysics Data System (ADS)
Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe
2016-03-01
An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.
Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam
2016-04-01
BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.
Performance of an improved first generation optical CT scanner for 3D dosimetry
NASA Astrophysics Data System (ADS)
Qian, Xin; Adamovics, John; Wuu, Cheng-Shie
2013-12-01
Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans.
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Jakubowska, A; Rozkrut, D; Antoniou, A; Hamann, U; Scott, R J; McGuffog, L; Healy, S; Sinilnikova, O M; Rennert, G; Lejbkowicz, F; Flugelman, A; Andrulis, I L; Glendon, G; Ozcelik, H; Thomassen, M; Paligo, M; Aretini, P; Kantala, J; Aroer, B; von Wachenfeldt, A; Liljegren, A; Loman, N; Herbst, K; Kristoffersson, U; Rosenquist, R; Karlsson, P; Stenmark-Askmalm, M; Melin, B; Nathanson, K L; Domchek, S M; Byrski, T; Huzarski, T; Gronwald, J; Menkiszak, J; Cybulski, C; Serrano, P; Osorio, A; Cajal, T R; Tsitlaidou, M; Benítez, J; Gilbert, M; Rookus, M; Aalfs, C M; Kluijt, I; Boessenkool-Pape, J L; Meijers-Heijboer, H E J; Oosterwijk, J C; van Asperen, C J; Blok, M J; Nelen, M R; van den Ouweland, A M W; Seynaeve, C; van der Luijt, R B; Devilee, P; Easton, D F; Peock, S; Frost, D; Platte, R; Ellis, S D; Fineberg, E; Evans, D G; Lalloo, F; Eeles, R; Jacobs, C; Adlard, J; Davidson, R; Eccles, D; Cole, T; Cook, J; Godwin, A; Bove, B; Stoppa-Lyonnet, D; Caux-Moncoutier, V; Belotti, M; Tirapo, C; Mazoyer, S; Barjhoux, L; Boutry-Kryza, N; Pujol, P; Coupier, I; Peyrat, J-P; Vennin, P; Muller, D; Fricker, J-P; Venat-Bouvet, L; Johannsson, O Th; Isaacs, C; Schmutzler, R; Wappenschmidt, B; Meindl, A; Arnold, N; Varon-Mateeva, R; Niederacher, D; Sutter, C; Deissler, H; Preisler-Adams, S; Simard, J; Soucy, P; Durocher, F; Chenevix-Trench, G; Beesley, J; Chen, X; Rebbeck, T; Couch, F; Wang, X; Lindor, N; Fredericksen, Z; Pankratz, V S; Peterlongo, P; Bonanni, B; Fortuzzi, S; Peissel, B; Szabo, C; Mai, P L; Loud, J T; Lubinski, J
2012-01-01
Background: The variable penetrance of breast cancer in BRCA1/2 mutation carriers suggests that other genetic or environmental factors modify breast cancer risk. Two genes of special interest are prohibitin (PHB) and methylene-tetrahydrofolate reductase (MTHFR), both of which are important either directly or indirectly in maintaining genomic integrity. Methods: To evaluate the potential role of genetic variants within PHB and MTHFR in breast and ovarian cancer risk, 4102 BRCA1 and 2093 BRCA2 mutation carriers, and 6211 BRCA1 and 2902 BRCA2 carriers from the Consortium of Investigators of Modifiers of BRCA1 and BRCA2 (CIMBA) were genotyped for the PHB 1630 C>T (rs6917) polymorphism and the MTHFR 677 C>T (rs1801133) polymorphism, respectively. Results: There was no evidence of association between the PHB 1630 C>T and MTHFR 677 C>T polymorphisms with either disease for BRCA1 or BRCA2 mutation carriers when breast and ovarian cancer associations were evaluated separately. Analysis that evaluated associations for breast and ovarian cancer simultaneously showed some evidence that BRCA1 mutation carriers who had the rare homozygote genotype (TT) of the PHB 1630 C>T polymorphism were at increased risk of both breast and ovarian cancer (HR 1.50, 95%CI 1.10–2.04 and HR 2.16, 95%CI 1.24–3.76, respectively). However, there was no evidence of association under a multiplicative model for the effect of each minor allele. Conclusion: The PHB 1630TT genotype may modify breast and ovarian cancer risks in BRCA1 mutation carriers. This association need to be evaluated in larger series of BRCA1 mutation carriers. PMID:22669161
Cho, Chul-Hyun; Oh, Joo Han; Jung, Gu-Hee; Moon, Gi-Hyuk; Rhyou, In Hyeok; Yoon, Jong Pil; Lee, Ho Min
2015-10-01
As there is substantial variation in the classification and diagnosis of lateral clavicle fractures, proper management can be challenging. Although the Neer classification system modified by Craig has been widely used, no study has assessed its validity through inter- and intrarater agreement. To determine the inter- and intrarater agreement of the modified Neer classification system and associated treatment choice for lateral clavicle fractures and to assess whether 3-dimensional computed tomography (3D CT) improves the level of agreement. Cohort study (diagnosis); Level of evidence, 3. Nine experienced shoulder specialists and 9 orthopaedic fellows evaluated 52 patients with lateral clavicle fractures, completing fracture typing according to the modified Neer classification system and selecting a treatment choice for each case. Web-based assessment was performed using plain radiographs only, followed by the addition of 3D CT images 2 weeks later. This procedure was repeated 4 weeks later. Fleiss κ values were calculated to estimate the inter- and intrarater agreement. Based on plain radiographs only, the inter- and intrarater agreement of the modified Neer classification system was regarded as fair (κ = 0.344) and moderate (κ = 0.496), respectively; the inter- and intrarater agreement of treatment choice was both regarded as moderate (κ = 0.465 and 0.555, respectively). Based on the plain radiographs and 3D CT images, the inter- and intrarater agreement of the classification system was regarded as fair (κ = 0.317) and moderate (κ = 0.508), respectively; the inter- and intrarater agreement of treatment choice was regarded as moderate (κ = 0.463) and substantial (κ = 0.623), respectively. There were no significant differences in the level of agreement between the plain radiographs only and plain radiographs plus 3D CT images for any κ values (all P > .05). The level of interrater agreement of the modified Neer classification system for lateral clavicle fractures was fair. Additional 3D CT did not improve the overall level of interrater or intrarater agreement of the modified Neer classification system or associated treatment choice. To eliminate a common source of disagreement among surgeons, a new classification system to focus on unclassifiable fracture types is needed. © 2015 The Author(s).
Capsule endoscopy in neoplastic diseases
Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto
2008-01-01
Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies. PMID:18785274
ERIC Educational Resources Information Center
Zettle, Robert D.; Rains, Jeanetta C.; Hayes, Steven C.
2011-01-01
Several articles have recently questioned the distinction between acceptance and commitment therapy (ACT) and traditional cognitive therapy (CT). This study presents a reanalysis of data from Zettle and Rains that compared 12 weeks of group CT with group ACT. For theoretical reasons, Zettle and Rains also included a modified form of CT that did…
Zhou, Jian; Li, Xi; Yang, Linlin; Yan, Songlin; Wang, Mengmeng; Cheng, Dan; Chen, Qi; Dong, Yulin; Liu, Peng; Cai, Weiquan; Zhang, Chaocan
2015-10-29
A novel electrochemical sensor based on Cu-MOF-199 [Cu-MOF-199 = Cu3(BTC)2 (BTC = 1,3,5-benzenetricarboxylicacid)] and SWCNTs (single-walled carbon nanotubes) was fabricated for the simultaneous determination of hydroquinone (HQ) and catechol (CT). The modification procedure was carried out through casting SWCNTs on the bare glassy carbon electrode (GCE) and followed by the electrodeposition of Cu-MOF-199 on the SWCNTs modified electrode. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were performed to characterize the electrochemical performance and surface characteristics of the as-prepared sensor. The composite electrode exhibited an excellent electrocatalytic activity with increased electrochemical signals towards the oxidation of HQ and CT, owing to the synergistic effect of SWCNTs and Cu-MOF-199. Under the optimized condition, the linear response range were from 0.1 to 1453 μmol L(-1) (RHQ = 0.9999) for HQ and 0.1-1150 μmol L(-1) (RCT = 0.9990) for CT. The detection limits for HQ and CT were as low as 0.08 and 0.1 μmol L(-1), respectively. Moreover, the modified electrode presented the good reproducibility and the excellent anti-interference performance. The analytical performance of the developed sensor for the simultaneous detection of HQ and CT had been evaluated in practical samples with satisfying results. Copyright © 2015 Elsevier B.V. All rights reserved.
Gnapareddy, Bramaramba; Ahn, Sang Jung; Dugasani, Sreekantha Reddy; Kim, Jang Ah; Amin, Rashid; Mitta, Sekhar Babu; Vellampatti, Srivithya; Kim, Byeonghoon; Kulkarni, Atul; Kim, Taesung; Yun, Kyusik; LaBean, Thomas H; Park, Sung Ha
2015-11-01
We present two free-solution annealed DNA nanostructures consisting of either cross-tile CT1 or CT2. The proposed nanostructures exhibit two distinct structural morphologies, with one-dimensional (1D) nanotubes for CT1 and 2D nanolattices for CT2. When we perform mica-assisted growth annealing with CT1, a dramatic dimensional change occurs where the 1D nanotubes transform into 2D nanolattices due to the presence of the substrate. We assessed the coverage percentage of the 2D nanolattices grown on the mica substrate with CT1 and CT2 as a function of the concentration of the DNA monomer. Furthermore, we fabricated a scaffold cross-tile (SCT), which is a new design of a modified cross-tile that consists of four four-arm junctions with a square aspect ratio. For SCT, eight oligonucleotides are designed in such a way that adjacent strands with sticky ends can produce continuous arms in both the horizontal and vertical directions. The SCT was fabricated via free-solution annealing, and self-assembled SCT produces 2D nanolattices with periodic square cavities. All structures were observed via atomic force microscopy. Finally, we fabricated divalent nickel ion (Ni(2+))- and trivalent dysprosium ion (Dy(3+))-modified 2D nanolattices constructed with CT2 on a quartz substrate, and the ion coordinations were examined via Raman spectroscopy. Copyright © 2015 Elsevier B.V. All rights reserved.
Combination cancer therapy by hapten-targeted prodrug-activating enzymes and cytokines.
Chuang, Kuo-Hsiang; Cheng, Chiu-Min; Roffler, Steve R; Lu, Yu-Lin; Lin, Shiu-Ru; Wang, Jaw-Yuan; Tzou, Wen-Shyong; Su, Yu-Cheng; Chen, Bing-Mae; Cheng, Tian-Lu
2006-01-01
Combination therapy can help overcome limitations in the treatment of heterogeneous tumors. In the current study, we examined whether multiple therapeutic agents could be targeted to anti-dansyl single-chain antibodies (DNS scFv) that were anchored on the plasma membrane of cancer cells. Functional DNS scFv could be stably expressed on CT-26 colon cancer cells both in vitro and in vivo. Dansyl moieties were covalently attached to recombinant beta-glucuronidase (betaG) and interleukin 2 (IL-2) via a flexible poly(ethylene glycol) linker to form DNS-PEG-betaG and DNS-PEG-IL-2 conjugates. The conjugates displayed enzymatic and splenocyte-stimulatory activities, respectively, that were similar to those of the unmodified proteins. The conjugates selectively bound CT-26 cells that expressed anti-DNS scFv (CT-26/DNS cells) but not CT-26 cells that expressed control scFv (CT-26/phOx cells). DNS-PEG-betaG preferentially activated a glucuronide prodrug (BHAMG) of p-hydroxy aniline mustard at CT-26/DNS cells in culture and accumulated in subcutaneous CT-26/DNS tumors after intravenous administration. Systemic administration of DNS-PEG-IL-2 or DNS-PEG-betaG and BHAMG significantly delayed the growth of CT-26/DNS but not control CT-26/phOx tumors. Combination treatment with DNS-PEG-betaG and BHAMG followed by DNS-PEG-IL-2 therapy significantly suppressed the growth of CT-26/DNS tumors as compared to either single-agent regimen. These results show that at least two DNS-modified therapeutic agents can be selectively delivered to DNS scFv receptors in vitro and in vivo, allowing combination therapy of DNS scFv-modified tumors.
Zhao, Dehua; Jiang, Hao; Yang, Tangwu; Cai, Ying; Xu, Delin; An, Shuqing
2012-03-01
Classification trees (CT) have been used successfully in the past to classify aquatic vegetation from spectral indices (SI) obtained from remotely-sensed images. However, applying CT models developed for certain image dates to other time periods within the same year or among different years can reduce the classification accuracy. In this study, we developed CT models with modified thresholds using extreme SI values (CT(m)) to improve the stability of the models when applying them to different time periods. A total of 903 ground-truth samples were obtained in September of 2009 and 2010 and classified as emergent, floating-leaf, or submerged vegetation or other cover types. Classification trees were developed for 2009 (Model-09) and 2010 (Model-10) using field samples and a combination of two images from winter and summer. Overall accuracies of these models were 92.8% and 94.9%, respectively, which confirmed the ability of CT analysis to map aquatic vegetation in Taihu Lake. However, Model-10 had only 58.9-71.6% classification accuracy and 31.1-58.3% agreement (i.e., pixels classified the same in the two maps) for aquatic vegetation when it was applied to image pairs from both a different time period in 2010 and a similar time period in 2009. We developed a method to estimate the effects of extrinsic (EF) and intrinsic (IF) factors on model uncertainty using Modis images. Results indicated that 71.1% of the instability in classification between time periods was due to EF, which might include changes in atmospheric conditions, sun-view angle and water quality. The remainder was due to IF, such as phenological and growth status differences between time periods. The modified version of Model-10 (i.e. CT(m)) performed better than traditional CT with different image dates. When applied to 2009 images, the CT(m) version of Model-10 had very similar thresholds and performance as Model-09, with overall accuracies of 92.8% and 90.5% for Model-09 and the CT(m) version of Model-10, respectively. CT(m) decreased the variability related to EF and IF and thereby improved the applicability of the models to different time periods. In both practice and theory, our results suggested that CT(m) was more stable than traditional CT models and could be used to map aquatic vegetation in time periods other than the one for which the model was developed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Daghini, Elena; Juillard, Laurent; Haas, John A; Krier, James D; Romero, Juan C; Lerman, Lilach O
2007-02-01
To prospectively compare in pigs three mathematic models for assessment of glomerular filtration rate (GFR) on electron-beam (EB) computed tomographic (CT) images, with concurrent inulin clearance serving as the reference standard. This study was approved by the institutional animal care and use committee. Inulin clearance was measured in nine pigs (18 kidneys) and compared with single-kidney GFR assessed from renal time-attenuation curves (TACs) obtained with EB CT before and after infusion of the vasodilator acetylcholine. CT-derived GFR was calculated with the original and modified Patlak methods and with previously validated extended gamma variate modeling of first-pass cortical TACs. Statistical analysis was performed to assess correlation between CT methods and inulin clearance for estimation of GFR with least-squares regression analysis and Bland-Altman graphical representation. Comparisons within groups were performed with a paired t test. GFR assessed with the original Patlak method indicated poor correlation with inulin clearance, whereas GFR assessed with the modified Patlak method (P < .001, r = 0.75) and with gamma variate modeling (P < .001, r = 0.79) correlated significantly with inulin clearance and indicated an increase in response to acetylcholine. CT-derived estimates of GFR can be significantly improved by modifications in image analysis methods (eg, use of a cortical region of interest). (c) RSNA, 2007.
Calcitonin and calcitonin receptors: bone and beyond
Pondel, Marc
2000-01-01
Calcitonin (CT), a 32 amino acid peptide hormone produced primarily by the thyroid, and its receptor (CTR) are well known for their ability to regulate osteoclast mediated bone resorption and enhance Ca2+ excretion by the kidney. However, recent studies now suggest that CT and CTRs may play an important role in a variety of processes as wide ranging as embryonic/foetal development and sperm function/physiology. In this review article, CT and CTR gene transcription, signal transduction and function are addressed. The effects of CT on the physiology of a variety of organ systems are discussed and the relationship between polymorphisms in the CTR gene and bone mineral density (BMD)/osteoporosis is examined. Recent studies demonstrating the ability of receptor activity modifying proteins (RAMPs) to post-translationally modify the calcitonin receptor-like receptor (CRLR) are detailed and studies employing transgenic mouse technology to determine the temporal and tissue specific transcriptional activity of the CTR gene in vivo are discussed. PMID:11298188
Cerrillo, Elena; Beltrán, Belén; Pous, Salvador; Echarri, Ana; Gallego, Jose Carlos; Iborra, Marisa; Pamies, Jose; Nos, Pilar
2015-07-01
Magnetic resonance enterography (MRE) is an effective method of assessing small bowel Crohn's disease (CD). Fecal calprotectin (FC) correlates well with endoscopic disease activity. We aimed to evaluate the correlation between FC and disease activity according to MRE and surgical pathology in small bowel CD. One hundred twenty consecutive patients with ileal CD who underwent MRE assessment were included. Clinical data, C-reactive protein and FC, radiological and histological variables were obtained. Clinical activity was evaluated by the Harvey-Bradshaw Index and FC by enzyme-linked immunosorbent assay. MRE activity was assessed by means of the Magnetic Resonance Index of Activity score. Chiorean's score was used to grade pathological inflammation in surgical specimens. Seventy-five patients (62.5%) were in clinical remission (Harvey-Bradshaw Index < 5) and 45 (37.5%) had active disease (Harvey-Bradshaw Index ≥ 5). The Magnetic Resonance Index of Activity score was significantly associated with FC levels (P < 0.01), with a moderate overall correlation (Spearman's r = 0.56, P < 0.001). FC reflected MRE inflammatory activity with an area under the receiver operating characteristic curve of 0.914 (confidence interval, 0.849-0.958; P < 0.001). A cutoff value of 166.50 μg/g had 90% sensitivity, 74% specificity, 89% positive predictive value, and 76% negative predictive value for diagnosis of inflammation. Twenty-eight of 120 patients were operated. Surgical pathology showed a good agreement with FC for moderate (P = 0.03) and severe (P = 0.01) Chiorean's index. No relationship was detected for C-reactive protein. FC correlates with the degree of MRE inflammatory activity and with surgical pathology damage in ileal CD. Thus, FC could be a surrogate marker of disease control used to select patients for MRE assessment and therapeutic adjustment.
Dykes, Dana M.H.; Towbin, Alexander J.; Bonkowski, Erin; Chalk, Claudia; Bezold, Ramona; Lake, Kathleen; Kim, Mi-Ok; Heubi, James E.; Trapnell, Bruce C.; Podberesky, Daniel J.; Denson, Lee A.
2013-01-01
Background Crohn disease (CD) patients with elevated Granulocyte-Macrophage Colony-Stimulating Factor auto-antibodies (GM-CSF Ab) are more likely to develop stricturing behavior requiring surgery. Computed Tomography or Magnetic Resonance Enterography (CTE or MRE) may detect luminal narrowing (LN) prior to stricture development. Objective To determine whether CD patients with elevated GM-CSF Ab (≥ 1.6 mcg/mL) have a higher prevalence of LN and stricturing on CTE or MRE. Methods A single center, cross-sectional study of 153 pediatric CD patients and controls undergoing CTE or MRE. A novel scoring system evaluated for disease activity, presence of LN, stricture, intra-abdominal abscess, or fistulae Ouutcomes were compared with respect to antibody status using Fisher's exact test, logistic regression, and the unpaired t-test. Results GM-CSF Ab were elevated in CD patients (n=114) with a median (IQR) GM-CSF Ab level of 2.3 mcg/mL (0.5, 6.6) compared with healthy and disease controls, p=0.001. Ileal disease location was more common in CD patients with high GM-CSF Ab, p<0.001. Luminal narrowing increased from 39% in CD patients with low GM-CSF Ab to 71% in those with high levels (p=0.004). High GM-CSF Ab remained significantly associated with LN in a multivariate logistic model. Stricturing increased from 4% in CD patients with low GM-CSF Ab to 19% in those with high GM-CSF Ab (p=0.03). Conclusions Pediatric CD patients with high GM-CSF Ab levels have a higher prevalence of LN on CTE or MRE. Further study will be needed to determine whether medical therapy will reduce progression to stricturing behavior in these patients. PMID:23893081
Assa, Amit; Amitai, Michal; Greer, Mary-Louise; Castro, Denise A; Kuint, Ruth C; Martínez-León, Maria; Herman-Sucharska, Izabela; Coppenrath, Eva; Anupindi, Sudha; Towbin, Alexander; Moote, Douglas; Konen, Osnat; Pratt, Li-Tal; Griffiths, Anne; Turner, Dan
2017-09-01
Data on the outcomes of children with perianal Crohn disease (pCD) are limited, although its presence is often used for justifying early use of biologics. We aimed to assess whether pCD in children is associated with more severe outcomes as found in adults. Data were extracted from the ImageKids database, a prospective, multicenter, longitudinal cohort study. The study enrolled 246 children at disease onset or thereafter. All patients underwent comprehensive clinical, endoscopic, and radiologic evaluation at enrollment; 98 children had repeat evaluation at 18 months. Of the 234 included patients (mean age 14.2 ± 2.4 years; 131 [56%] boys), 57 (24%) had perianal findings, whereas only 21 (9%) had fistulizing perianal disease. Children with pCD had reduced weight and height z scores compared with non-pCD patients (-0.9 vs -0.35, P = 0.03 and -0.68 vs -0.23, respectively; P = 0.04), higher weighted pediatric CD activity index (32 [interquartile range 16-50] vs 20 [8-37]; P = 0.004), lower serum albumin (3.6 ± 0.7 vs 4.5 ± 0.8, P = 0.016), and higher magnetic resonance enterography global inflammatory score (P = 0.04). Children with pCD had more rectal (57% vs 38%, P = 0.04), and jejunal involvement (31% vs 11% P = 0.003) and a higher prevalence of granulomas (64% vs 23%, P = 0.0001). Magnetic resonance enterography-based damage scores did not differ between groups. Patients with skin tags/fissures only, had similar clinical, endoscopic, and radiologic characteristics as patients with no perianal findings. Pediatric patients with pCD with fistulizing disease have distinct phenotypic features and a predisposition to a greater inflammatory burden.
Comparison of 3% sorbitol vs psyllium fibre as oral contrast agents in MR enterography.
Saini, Sidharth; Colak, Errol; Anthwal, Shalini; Vlachou, Paraskevi A; Raikhlin, Antony; Kirpalani, Anish
2014-10-01
To compare the degree of small bowel distension achieved by 3% sorbitol, a high osmolarity solution, and a psyllium-based bulk fibre as oral contrast agents (OCAs) in MR enterography (MRE). This retrospective study was approved by our institutional review board. A total of 45 consecutive normal MRE examinations (sorbitol, n = 20; psyllium, n = 25) were reviewed. The patients received either 1.5 l of 3% sorbitol or 2 l of 1.6 g kg(-1) psyllium prior to imaging. Quantitative small bowel distension measurements were taken in five segments: proximal jejunum, distal jejunum, proximal ileum, distal ileum and terminal ileum by two independent radiologists. Distension in these five segments was also qualitatively graded from 0 (very poor) to 4 (excellent) by two additional independent radiologists. Statistical analysis comparing the groups and assessing agreement included intraclass coefficients, Student's t-test and Mann-Whitney U-test. Small bowel distension was not significantly different in any of the five small bowel segments between the use of sorbitol and psyllium as OCAs in both the qualitative (p = 0.338-0.908) and quantitative assessments (p = 0.083-0.856). The mean bowel distension achieved was 20.1 ± 2.2 mm for sorbitol and 19.8 ± 2.5 mm for psyllium (p = 0.722). Visualization of the ileum was good or excellent in 65% of the examinations in both groups. Sorbitol and psyllium are not significantly different at distending the small bowel and both may be used as OCAs for MRE studies. This is the first study to directly compare the degree of distension in MRE between these two common, readily available and inexpensive OCAs.
Lahat, Adi; Kopylov, Uri; Amitai, Marianne M; Neuman, Sandra; Levhar, Nina; Yablecovitch, Doron; Avidan, Benjamin; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Eliakim, Rami
2016-01-01
Background Despite differences in the information obtained by capsule endoscopy (CE) and magnetic resonance enterography (MRE), one of these modalities is usually needed when evaluating disease activity. There are no data on patients’ preference that would help guide the choice between these two modalities in these instances. Aim To compare patients’ tolerance and preference to MRE versus CE. Patients and methods Patients with known small bowel Crohn’s disease (CD) in clinical remission (Crohn’s disease activity index [CDAI] <150) or with mild symptoms (CDAI <220) were prospectively recruited. All patients underwent MRE followed by CE. Patients were asked to fill out a questionnaire addressing specific points regarding inconvenience during the preparation for the procedures, the procedures, and postprocedures. Side effects and procedure preference were addressed. Questionnaires were included for analysis only when more than 95% of the items were addressed. Results Fifty-six patients fulfilled inclusion criteria. Pre-exam discomfort, during-exam discomfort, nausea, vomiting, bloating, and abdominal pain were all significantly more prominent in MRE as compared to CE (P<0.0001, P<0.0001, P<0.0001, P=0.009, P=0.0002, P<0.0001, respectively). MRE was perceived as a more difficult procedure (P<0.0001). Furthermore, MRE was associated with a specific adverse event – claustrophobia. Seventy-eight percent of patients (44 patients) preferred to repeat CE as compared to 22% (P<0.0001) who preferred MRE. Conclusion CE was better tolerated by CD patients compared to MRE and was preferred by 78% of patients. The superior tolerability of CE should be considered along with the diagnostic features, and more data sought when choosing between these two modalities for CD patients for long-term follow-up. PMID:27354774
Kopylov, Uri; Klang, Eyal; Yablecovitch, Doron; Lahat, Adi; Avidan, Benjamin; Neuman, Sandra; Levhar, Nina; Greener, Tomer; Rozendorn, Noa; Beytelman, Arkadi; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Amitai, Marianne M.; Eliakim, Rami
2016-01-01
Background: Video capsule endoscopy (VCE) and magnetic resonance enterography (MRE) are the prime modalities for the evaluation of small bowel (SB) Crohn’s disease (CD). Mucosal inflammation on VCE is quantified using the Lewis score (LS). Diffusion-weighted (DW) magnetic resonance imaging (MRI) allows for accurate assessment of SB inflammation without administration of intravenous contrast material. The Magnetic Resonance Index of Activity (MaRiA) and the Clermont index are quantitative activity indices validated for contrast-enhanced MRE and DW-MRE, respectively. The aim of this study was to compare the quantification of distal SB inflammation by VCE and MR-related activity indices. Methods: Patients with known quiescent SB CD were prospectively recruited and underwent MRE and VCE. LS, MaRIA and Clermont scores were calculated for the distal SB. Results: Both MRI-based indices significantly correlated with the LS and the Clermont index (r = 0.50, p = 0.001 and r = 0.53, p = 0.001, respectively). Both MaRIA and Clermont scores were significantly lower in patients with mucosal healing (LS < 135). The area under the curve (AUC) with both MR scores was moderate for prediction of any mucosal inflammation (LS ⩾ 135) and excellent for prediction of moderate-to-severe inflammation (LS ⩾ 790) (0.71 and 0.74 versus 0.93 and 0.91 for MaRIA and Clermont score, respectively). Conclusions: Modest correlation between VCE- and MRE-based quantitative indices of inflammation in patients with quiescent SB CD was observed. Between-modality correlation was higher in patients with endoscopically severe disease. DW-MRE gauged by Clermont score was at least as accurate as contrast-enhanced MRE for quantification of SB inflammation. PMID:27582877
NASA Astrophysics Data System (ADS)
Strocchi, Sabina; Colli, Vittoria; Novario, Raffaele; Carrafiello, Gianpaolo; Giorgianni, Andrea; Macchi, Aldo; Fugazzola, Carlo; Conte, Leopoldo
2007-03-01
Aim of this work is to compare the performances of a Xoran Technologies i-CAT Cone Beam CT for dental applications with those of a standard total body multislice CT (Toshiba Aquilion 64 multislice) used for dental examinations. Image quality and doses to patients have been compared for the three main i-CAT protocols, the Toshiba standard protocol and a Toshiba modified protocol. Images of two phantoms have been acquired: a standard CT quality control phantom and an Alderson Rando ® anthropomorphic phantom. Image noise, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and geometric accuracy have been considered. Clinical image quality was assessed. Effective dose and doses to main head and neck organs were evaluated by means of thermo-luminescent dosimeters (TLD-100) placed in the anthropomorphic phantom. A Quality Index (QI), defined as the ratio of squared CNR to effective dose, has been evaluated. The evaluated effective doses range from 0.06 mSv (i-CAT 10 s protocol) to 2.37 mSv (Toshiba standard protocol). The Toshiba modified protocol (halved tube current, higher pitch value) imparts lower effective dose (0.99 mSv). The conventional CT device provides lower image noise and better SNR, but clinical effectiveness similar to that of dedicated dental CT (comparable CNR and clinical judgment). Consequently, QI values are much higher for this second CT scanner. No geometric distortion has been observed with both devices. As a conclusion, dental volumetric CT supplies adequate image quality to clinical purposes, at doses that are really lower than those imparted by a conventional CT device.
Effect of {sup 18}F-FDG PET/CT Imaging in Patients With Clinical Stage II and III Breast Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groheux, David; Moretti, Jean-Luc; EAD Imagerie Moleculaire Diagnostique et Ciblage Therapeutique, IUH, University of Paris VII, Paris
2008-07-01
Purpose: To investigate the potential effect of using {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in the initial assessment of patients with clinical Stage II or III breast cancer. Methods and Materials: During 14 consecutive months, 39 patients (40 tumors) who presented with Stage II or III breast cancer on the basis of a routine extension assessment were prospectively included in this study. PET/CT was performed in addition to the initial assessment. Results: In 3 cases, PET/CT showed extra-axillary lymph node involvement that had not been demonstrated with conventional techniques. Two of these patients had hypermetabolic lymph nodes in themore » subpectoral and infraclavicular regions, and the third had a hypermetabolic internal mammary node. PET/CT showed distant uptake in 4 women. Of these 4 women, 1 had pleural involvement and 3 had bone metastasis. Overall, of the 39 women, the PET/CT results modified the initial stage in 7 (18%). The modified staging altered the treatment plan for 5 patients (13%). It led to radiotherapy in 4 patients (bone metastasis, pleural lesion, subpectoral lymph nodes, and internal mammary nodes) and excision of, and radiotherapy to, the infraclavicular lymph nodes in 1 patient. Conclusions: PET/CT can provide information on extra-axillary lymph node involvement and can uncover occult distant metastases in a significant percentage of patients. Therefore, initial PET/CT could enable better treatment planning for patients with Stage II and III breast cancer.« less
Di, Li-Jun; Byun, Jung S; Wong, Madeline M; Wakano, Clay; Taylor, Tara; Bilke, Sven; Baek, Songjoon; Hunter, Kent; Yang, Howard; Lee, Maxwell; Zvosec, Cecilia; Khramtsova, Galina; Cheng, Fan; Perou, Charles M; Miller, C Ryan; Raab, Rachel; Olopade, Olufunmilayo I; Gardner, Kevin
2013-01-01
The C-terminal binding protein (CtBP) is a NADH-dependent transcriptional repressor that links carbohydrate metabolism to epigenetic regulation by recruiting diverse histone-modifying complexes to chromatin. Here global profiling of CtBP in breast cancer cells reveals that it drives epithelial-to-mesenchymal transition, stem cell pathways and genome instability. CtBP expression induces mesenchymal and stem cell-like features, whereas CtBP depletion or caloric restriction reverses gene repression and increases DNA repair. Multiple members of the CtBP-targeted gene network are selectively downregulated in aggressive breast cancer subtypes. Differential expression of CtBP-targeted genes predicts poor clinical outcome in breast cancer patients, and elevated levels of CtBP in patient tumours predict shorter median survival. Finally, both CtBP promoter targeting and gene repression can be reversed by small molecule inhibition. These findings define broad roles for CtBP in breast cancer biology and suggest novel chromatin-based strategies for pharmacologic and metabolic intervention in cancer.
Yoshida, Atsushi; Ueno, Fumiaki; Morizane, Toshio; Joh, Takashi; Kamiya, Takeshi; Takahashi, Shin''ichi; Tokunaga, Kengo; Iwakiri, Ryuichi; Kinoshita, Yoshikazu; Suzuki, Hidekazu; Naito, Yuji; Uchiyama, Kazuhiko; Fukodo, Shin; Chan, Francis K L; Halm, Ki-Baik; Kachintorn, Udom; Fock, Kwong Ming; Rani, Abdul Aziz; Syam, Ari Fahrial; Sollano, Jose D; Zhu, Qi
2017-01-01
Diagnostic and therapeutic strategies in inflammatory bowel disease (IBD) vary among countries in terms of availability of modalities, affordability of health care resource, health care policy and cultural background. This may be the case in different countries in Eastern Asia. The aim of this study was to determine and understand the differences in diagnostic and therapeutic strategies of IBD between Japan and the rest of Asian countries (ROA). Questionnaires with regard to clinical practice in IBD were distributed to members of the International Gastroenterology Consensus Symposium Study Group. The responders were allowed to select multiple items for each question, as multiple modalities are frequently utilized in the diagnosis and the management of IBD. Dependency and independency of selected items for each question were evaluated by the Bayesian network analysis. The selected diagnostic modalities were not very different between Japan and ROA, except for those related to small bowel investigations. Balloon-assisted enteroscopy and small bowel follow through are frequently used in Japan, while CT/MR enterography is popular in ROA. Therapeutic modalities for IBD depend on availability of such modalities in clinical practice. As far as modalities commonly available in both regions are concerned, there seemed to be similarity in the selection of each therapeutic modality. However, evaluation of dependency of separate therapeutic modalities by Bayesian network analysis disclosed some difference in therapeutic strategies between Japan and ROA. Although selected modalities showed some similarity, Bayesian network analysis elicited certain differences in the clinical approaches combining multiple modalities in various aspects of IBD between Japan and ROA. © 2016 S. Karger AG, Basel.
Jimenez-Jimenez, E; Mateos, P; Aymar, N; Roncero, R; Ortiz, I; Gimenez, M; Pardo, J; Salinas, J; Sabater, S
2018-05-02
Evidence supporting the use of 18F-FDG-PET/CT in the segmentation process of oesophageal cancer for radiotherapy planning is limited. Our aim was to compare the volumes and tumour lengths defined by fused PET/CT vs. CT simulation. Twenty-nine patients were analyzed. All patients underwent a single PET/CT simulation scan. Two separate GTVs were defined: one based on CT data alone and another based on fused PET/CT data. Volume sizes for both data sets were compared and the spatial overlap was assessed by the Dice similarity coefficient (DSC). The gross tumour volume (GTVtumour) and maximum tumour diameter were greater by PET/CT, and length of primary tumour was greater by CT, but differences were not statistically significant. However, the gross node volume (GTVnode) was significantly greater by PET/CT. The DSC analysis showed excellent agreement for GTVtumour, 0.72, but was very low for GTVnode, 0.25. Our study shows that the volume definition by PET/CT and CT data differs. CT simulation, without taking into account PET/CT information, might leave cancer-involved nodes out of the radiotherapy-delineated volumes.
33 CFR 100.102 - Great Connecticut River Raft Race, Middletown, CT.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Great Connecticut River Raft Race... Raft Race, Middletown, CT. (a) Regulated Area. That section of the Connecticut River between Dart.... (1) The Coast Guard patrol commander may delay, modify, or cancel the race as conditions or...
Speed of gravitational waves and black hole hair
NASA Astrophysics Data System (ADS)
Tattersall, Oliver J.; Ferreira, Pedro G.; Lagos, Macarena
2018-04-01
The recent detection of GRB 170817A and GW170817 constrains the speed of gravity waves cT to be that of light, which severely restricts the landscape of modified gravity theories that impact the cosmological evolution of the Universe. In this work, we investigate the presence of black hole hair in the remaining viable cosmological theories of modified gravity that respect the constraint cT=1 . We focus mainly on scalar-tensor theories of gravity, analyzing static, asymptotically flat black holes in Horndeski, Beyond Horndeski, Einstein-scalar-Gauss-Bonnet, and Chern-Simons theories. We find that in all of the cases considered here, theories that are cosmologically relevant and respect cT=1 do not allow for hair, or have negligible hair. We further comment on vector-tensor theories including Einstein-Yang-Mills, Einstein-Aether, and generalized Proca theories, as well as bimetric theories.
Modeling CO2 degassing and pH in a stream-aquifer system
Choi, J.; Hulseapple, S.M.; Conklin, M.H.; Harvey, J.W.
1998-01-01
Pinal Creek, Arizona receives an inflow of ground water with high dissolved inorganic carbon (57-75 mg/l) and low pH (5.8-6.3). There is an observed increase of in-stream pH from approximately 6.0-7.8 over the 3 km downstream of the point of groundwater inflow. We hypothesized that CO2 gas-exchange was the most important factor causing the pH increase in this stream-aquifer system. An existing transport model, for coupled ground water-surface water systems (OTIS), was modified to include carbonate equilibria and CO2 degassing, used to simulate alkalinity, total dissolved inorganic carbon (C(T)), and pH in Pinal Creek. Because of the non-linear relation between pH and C(T), the modified transport model used the numerical iteration method to solve the non-linearity. The transport model parameters were determined by the injection of two tracers, bromide and propane. The resulting simulations of alkalinity, C(T) and pH reproduced, without fitting, the overall trends in downstream concentrations. A multi-parametric sensitivity analysis (MPSA) was used to identify the relative sensitivities of the predictions to six of the physical and chemical parameters used in the transport model. MPSA results implied that C(T) and pH in stream water were controlled by the mixing of ground water with stream water and CO2 degassing. The relative importance of these two processes varied spatially depending on the hydrologic conditions, such as stream flow velocity and whether a reach gained or lost stream water caused by the interaction with the ground water. The coupled transport model with CO2 degassing and generalized sensitivity analysis presented in this study can be applied to evaluate carbon transport and pH in other coupled stream-ground water systems.An existing transport model for coupled groundwater-surface water systems was modified to include carbonate equilibria and CO2 degassing. The modified model was used to simulate alkalinity, total dissolved inorganic carbon (CT) and pH in Pinal Creek. The model used the numerical iteration method to solve the nonlinear relation between pH and CT. A multi-parametric sensitivity analysis (MPSA) was used to identify the relative sensitivities of the predictions to six of the physical and chemical parameters used in the transport model. MPSA results implied that CT and pH in the stream water were controlled by the mixing of groundwater with stream water and CO2 degassing.
Electrocardiogram‐gated coronary CT angiography dose estimates using ImPACT
Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Koshida, Kichiro; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Toyama, Hiroshi; Kato, Ryoichi
2016-01-01
The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), prospective CTA, continuous CTA/cardiac function analysis (CFA), and CTA/CFA modulation. Accordingly, we clarified the CT dose index (CTDI) to determine the relationship between heart rate (HR) and X‐ray exposure. As a secondary objective, we compared radiation doses using modified ImPACT, a whole‐body dosimetry phantom study, and the k‐factor method to verify the validity of the dose results obtained with modified ImPACT. The effective dose determined for the reference person (4.66 mSv at 60 beats per minute (bpm) and 33.43 mSv at 90 bpm) were approximately 10% less than those determined for the phantom study (5.28 mSv and 36.68 mSv). The effective doses according to the k‐factor (0.014 mSv·mGy−1·cm−1; 2.57 mSv and 17.10 mSv) were significantly lower than those obtained with the other two methods. In the present study, we have shown that ImPACT, when modified for cardiac applications, can assess both absorbed and effective doses. The results of our dose comparison indicate that modified ImPACT dose assessment is a promising and practical method for evaluating coronary CTA. PACS number(s): 87.57.Q‐, 87.59.Dj, 87.57.uq PMID:27455500
SU-G-IeP2-10: Lens Dose Reduction by Patient Position Modification During Neck CT Exams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosher, E; Lee, C; Butman, J
Purpose: Irradiation of the lens during a neck CT may increase a patient’s risk of developing cataracts later in life. Radiologists and technologists at the National Institutes of Health Clinical Center (NIHCC) have developed new CT imaging protocols that include a reduction in scan range and modifying neck positioning using a head tilt. This study will evaluate the efficacy of this protocol in the reduction of lens dose. Methods: We retrieved CT images of five male patients who had two sets of CT images: before and after the implementation of the new protocol. The lens doses before the new protocolmore » were calculated using an in-house CT dose calculator, National Cancer Institute dosimetry system for CT (NCICT), where computational human phantoms with no head tilt are included. We also calculated the lens dose for the patient CT conducted after the new protocol by using an adult male computational phantom with the neck position deformed to match the angle of the head tilt. We also calculated the doses to other radiosensitive organs including the globes of the eye, brain, pituitary gland and salivary glands before and after head tilt. Results: Our dose calculations demonstrated that modifying neck position reduced dose to the lens by 89% on average (range: 86–96%). Globe, brain, pituitary and salivary gland doses also decreased by an average of 65% (51–95%), 38% (−8–66%), 34% (−43–84%) and 14% (13–14%), respectively. The new protocol resulted in a nearly ten-fold decrease in lens dose. Conclusion: The use of a head tilt and scan range reduction is an easy and effective method to reduce radiation exposure to the lens and other radiosensitive organs, while still allowing for the inclusion of critical neck structures in the CT image. We are expanding our study to a total of 10 males and 10 females.« less
Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images
Yang, Juan; Zhang, You; Yin, Yong
2015-01-01
Fusion of anatomic information in computed tomography (CT) and functional information in F18‐FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined F18‐FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole‐body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)‐based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point‐wise mutual information (PMI) diffeomorphic‐based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB‐approved study. Whole‐body PET and CT images were acquired from a combined F18‐FDG PET/CT scanner for each patient. The modified Hausdorff distance (dMH) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of dMH were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI‐based demons and the PMI diffeomorphic‐based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined F18‐FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic‐based demons algorithm was more accurate than the GMI‐based demons algorithm in registering PET/CT esophageal images. PACS numbers: 87.57.nj, 87.57. Q‐, 87.57.uk PMID:26218993
Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.
Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong
2015-07-08
Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons algorithm was more accurate than the GMI-based demons algorithm in registering PET/CT esophageal images.
User’s Supplement to MIL-STD-740-2 Modified for Measurements to 20 KHz
1989-10-01
Process Compressor Div. 100 Chemung Street 1 AMI Research Painted Post, NY 14870 2 Captain Walk 1 James Seibert New London, CT 06320 1 Mark Clifton 1...CT 06340-4909 942 Memorial Pkwy. 1 Wilf Kalbach Phillipsburg, NJ 08865 1 David Mewha 1 Timothy Luce 1 Ed Miller 1 Kevin Brimmer 2 ITW Linac 1 Robert
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J.; Siva, Shankar
Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metricsmore » model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.« less
Robot-assisted partial nephrectomy for large renal masses: a multi-institutional series.
Delto, Joan C; Paulucci, David; Helbig, Michael W; Badani, Ketan K; Eun, Daniel; Porter, James; Abaza, Ronney; Hemal, Ashok K; Bhandari, Akshay
2018-06-01
To compare peri-operative outcomes after robot-assisted partial nephrectomy (RAPN) for cT2a (7 to <10 cm) to cT1 tumours. Patients with a cT1a (n = 1 358, 76.4%), cT1b (n = 379, 21.3%) or cT2a (n = 41, 2.3%) renal mass were identified from a multi-institutional RAPN database. Intra- and postoperative outcomes were compared for cT2a masses vs cT1a and cT1b masses using multivariable regression models (linear, logistic, Poisson etc.), adjusting for operating surgeon and a modified R.E.N.A.L. nephrometry score that excluded the radius component. The median sizes for cT1a, cT1b and cT2a tumours were 2.5, 5.0 and 8.0 cm, respectively (P < 0.001) with modified R.E.N.A.L. nephrometry scores being 6.0, 6.5 and 7.0, respectively (cT1a, P < 0.001; cT1b, P = 0.105). RAPN for cT2a vs cT1a masses was associated with a 12% increase in operating time (P < 0.001), a 32% increase in estimated blood loss (P < 0.001), a 7% increase in ischaemia time (P = 0.008), a 3.93 higher odds of acute kidney injury at discharge (95% confidence interval [CI] 1.33, 8.76; P = 0.009) and a higher risk of recurrence (hazard ratio [HR] 10.9, 95% CI 1.31, 92.2; P = 0.027). RAPN for cT2a vs cT1b masses was associated with a 12% increase in blood loss (P = 0.036), a 5% increase in operating time (P = 0.062) and a marginally higher risk of recurrence (HR 11.2, 95% CI 0.77, 11.5; P = 0.059). RAPN for cT2a tumours was not associated with differences in complications (cT1a, P = 0.535; cT1b, P = 0.382), positive margins (cT1a, P = 0.972; cT1b, P = 0.681), length of stay (cT1a, P = 0.507; cT1b, P = 0.513) or renal function decline up to 24 months post-RAPN (cT1a, P = 0.124; cT1b, P = 0.467). For T2a tumours RAPN is a feasible treatment option in a select patient population when performed by experienced surgeons in institutions equipped to manage postoperative complications. Although RAPN was associated with greater blood loss and longer operating and ischaemia time in T2a tumours, it was not associated with greater complication or positive surgical margin rates compared with T1 tumours. Renal function preservation rates were equivalent for up to 24 months postoperatively; however, 12-month recurrence-free survival was significantly lower in the T2a group. Extended follow-up is required to further evaluate long-term survival. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
Density Measurement of Compact Toroid with Mach-Zehnder Interferometer
NASA Astrophysics Data System (ADS)
Laufman-Wollitzer, Lauren; Endrizzi, Doug; Brookhart, Matt; Flanagan, Ken; Forest, Cary
2016-10-01
Utilizing a magnetized coaxial plasma gun (MCPG) built by Tri Alpha Energy, a dense compact toroid (CT) is created and injected at high speed into the Wisconsin Plasma Astrophysics Laboratory (WiPAL) vessel. A modified Mach-Zehnder interferometer from the Line-Tied Reconnection Experiment (LTRX) provides an absolute measurement of electron density. The interferometer is located such that the beam intersects the plasma across the diameter of the MCPG drift region before the CT enters the vessel. This placement ensures that the measurement is taken before the CT expand. Results presented will be used to further analyze characteristics of the CT. Funding provided by DoE, NSF, and WISE Summer Research.
Gimbel, Ronald W; Pirrallo, Ronald G; Lowe, Steven C; Wright, David W; Zhang, Lu; Woo, Min-Jae; Fontelo, Paul; Liu, Fang; Connor, Zachary
2018-03-12
The frequency of head computed tomography (CT) imaging for mild head trauma patients has raised safety and cost concerns. Validated clinical decision rules exist in the published literature and on-line sources to guide medical image ordering but are often not used by emergency department (ED) clinicians. Using simulation, we explored whether the presentation of a clinical decision rule (i.e. Canadian CT Head Rule - CCHR), findings from malpractice cases related to clinicians not ordering CT imaging in mild head trauma cases, and estimated patient out-of-pocket cost might influence clinician brain CT ordering. Understanding what type and how information may influence clinical decision making in the ordering advanced medical imaging is important in shaping the optimal design and implementation of related clinical decision support systems. Multi-center, double-blinded simulation-based randomized controlled trial. Following standardized clinical vignette presentation, clinicians made an initial imaging decision for the patient. This was followed by additional information on decision support rules, malpractice outcome review, and patient cost; each with opportunity to modify their initial order. The malpractice and cost information differed by assigned group to test the any temporal relationship. The simulation closed with a second vignette and an imaging decision. One hundred sixteen of the 167 participants (66.9%) initially ordered a brain CT scan. After CCHR presentation, the number of clinicians ordering a CT dropped to 76 (45.8%), representing a 21.1% reduction in CT ordering (P = 0.002). This reduction in CT ordering was maintained, in comparison to initial imaging orders, when presented with malpractice review information (p = 0.002) and patient cost information (p = 0.002). About 57% of clinicians changed their order during study, while 43% never modified their imaging order. This study suggests that ED clinician brain CT imaging decisions may be influenced by clinical decision support rules, patient out-of-pocket cost information and findings from malpractice case review. NCT03449862 , February 27, 2018, Retrospectively registered.
Chalaye, Julia; Costentin, Charlotte E; Luciani, Alain; Amaddeo, Giuliana; Ganne-Carrié, Nathalie; Baranes, Laurence; Allaire, Manon; Calderaro, Julien; Azoulay, Daniel; Nahon, Pierre; Seror, Olivier; Mallat, Ariane; Soussan, Michael; Duvoux, Christophe; Itti, Emmanuel; Nault, Jean Charles
2018-03-06
Hepatocellular carcinoma (HCC) staging according to the Barcelona Clinical Liver Cancer (BCLC) classification is based on conventional imaging. The aim of our study was to assess the impact of dual-tracer 18F-fluorocholine and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) on tumor staging and treatment allocation. A total of 192 dual-tracer PET/CT scans (18F-fluorocholine and 18F-fluorodeoxyglucose PET/CT) were performed in 177 patients with HCC. BCLC staging and treatment proposal were retrospectively collected based on conventional imaging, along with any new lesions detected, and changes in BCLC classification or treatment allocation based on dual-tracer PET/CT. Patients were primarily men (87.5%) with cirrhosis (71%) due to alcohol ± non-alcoholic steatohepatitis (26%), viral infection (62%) or unknown causes (12%). Among 122 patients with PET/CT performed for staging, BCLC stage based on conventional imaging was 0/A in 61 patients (50%), B in 32 patients (26%) and C in 29 patients (24%). Dual-tracer PET/CT detected new lesions in 26 patients (21%), upgraded BCLC staging in 14 (11%) and modified treatment strategy in 17 (14%). In addition, dual-tracer PET/CT modified the final treatment in 4/9 (44%) patients with unexplained elevation of alpha-fetoprotein (AFP), 10/25 patients (40%) with doubtful lesions on conventional imaging and 3/36 patients (8%) waiting for liver transplantation without active HCC after tumor response following bridging therapy. When used for HCC staging, dual-tracer PET/CT enabled BCLC upgrading and treatment modification in 11% and 14% of patients, respectively. Dual-tracer PET/CT might also be useful in specific situations (an unexplained rise in AFP, doubtful lesions or pre-transplant evaluation of patients without active HCC). Using a combination of tracers 18F-fluorocholine and 18F-fluorodeoxyglucose when performing positron emission tomography/computed tomography (PET/CT), often called a PET scan, helps to identify new tumor lesions in patients with hepatocellular carcinoma. This technique enabled staging modification of patients' tumors and led to changes in treatment allocation in certain patients. Copyright © 2018. Published by Elsevier B.V.
Barkmeier, Daniel T; Dillman, Jonathan R; Al-Hawary, Mahmoud; Heider, Amer; Davenport, Matthew S; Smith, Ethan A; Adler, Jeremy
2016-04-01
Crohn disease is a chronic inflammatory condition that can lead to intestinal strictures. The presence of fibrosis within strictures alters optimal management but is not reliably detected by current imaging methods. To correlate the MRI features of surgically resected small-bowel strictures in pediatric Crohn disease with histological inflammation and fibrosis scoring. We included children with Crohn disease who had symptomatic small-bowel strictures requiring surgical resection and had preoperative MR enterography (MRE) within 3 months of surgery (n = 20). Two blinded radiologists reviewed MRE examinations to document stricture-related findings. A pediatric pathologist scored stricture histological specimens for fibrosis (0-4) and inflammation (0-4). MRE findings were correlated with histological data using Spearman correlation (ρ) and exact logistic regression analysis. There was significant positive correlation between histological bowel wall fibrosis and inflammation in resected strictures (ρ = 0.55; P = 0.01). Confluent transmural histological fibrosis was associated with pre-stricture upstream small-bowel dilatation >3 cm at univariate (odds ratio [OR] = 51.7; 95% confidence interval [CI]: 7.6- > 999.9; P = 0.0002) and multivariate (OR = 43.4; 95% CI: 6.1- > 999.9; P = 0.0006, adjusted for age) analysis. The degree of bowel wall T2-weighted signal intensity failed to correlate with histological bowel wall fibrosis or inflammation (P-values >0.05). There were significant negative correlations between histological fibrosis score and patient age at resection (ρ = -0.48, P = 0.03), and time from diagnosis to surgery (ρ = -0.73, P = 0.0002). Histological fibrosis and inflammation co-exist in symptomatic pediatric Crohn disease small-bowel strictures and are positively correlated. Pre-stenotic upstream small-bowel dilatation greater than 3 cm is significantly associated with confluent transmural fibrosis.
Dubron, Céline; Avni, Freddy; Boutry, Nathalie; Turck, Dominique; Duhamel, Alain
2016-01-01
Objective: To evaluate prospectively the performance of diffusion-weighted imaging (DWI) for the detection of active lesions on MR enterography (MRE) in children with inflammatory bowel disease (IBD). Methods: MRE of 48 children (mean age 13 years) with suspected or known IBD were blindly analysed by 2 independent readers for the presence of active lesions. Two sets of imaging including DWI and gadolinium-enhanced imaging (GEI) were reviewed. A reader consensus was obtained. The gold standard was histopathological findings. In patient-level analysis and segment-level analysis, sensitivity and specificity were calculated for DWI and GEI and compared using McNemar's test or logistic random-effects models. Results: At least 1 active lesion was confirmed in 42 (87.5%) children. Sensitivity and specificity for the detection of at least one lesion were 88.1% (95% CI, 74.3–96.1) and 83.3% (95% CI, 35.9–99.6), respectively, for DWI and 66.7% (95% CI, 50.4–80.4) and 83.3% (95% CI, 35.9–99.6), respectively, for GEI. In segment-level analysis, sensitivity and specificity for the detection of specific segment lesions were 62.5% (95% CI, 48.1–75) and 97.1% (95% CI, 93.5–98.7), respectively, for DWI and 45.7% (95% CI, 30.8–61.3) and 98.2% (95% CI, 95.3–99.4), respectively, for GEI. The sensitivity of DWI was significantly better than that of GEI per patient (p = 0.004) and per segment (p = 0.028). Conclusion: DWI demonstrates better performance than GEI for the detection of active lesions in children with IBD. Advances in knowledge: Examination with no intravenous injection–DWI can replace T1 weighted images when paediatric patients are screened with MRE for IBD. Examination performed in free breathing is better tolerated by children. PMID:26838954
Dubron, Céline; Avni, Freddy; Boutry, Nathalie; Turck, Dominique; Duhamel, Alain; Amzallag-Bellenger, Elisa
2016-01-01
To evaluate prospectively the performance of diffusion-weighted imaging (DWI) for the detection of active lesions on MR enterography (MRE) in children with inflammatory bowel disease (IBD). MRE of 48 children (mean age 13 years) with suspected or known IBD were blindly analysed by 2 independent readers for the presence of active lesions. Two sets of imaging including DWI and gadolinium-enhanced imaging (GEI) were reviewed. A reader consensus was obtained. The gold standard was histopathological findings. In patient-level analysis and segment-level analysis, sensitivity and specificity were calculated for DWI and GEI and compared using McNemar's test or logistic random-effects models. At least 1 active lesion was confirmed in 42 (87.5%) children. Sensitivity and specificity for the detection of at least one lesion were 88.1% (95% CI, 74.3-96.1) and 83.3% (95% CI, 35.9-99.6), respectively, for DWI and 66.7% (95% CI, 50.4-80.4) and 83.3% (95% CI, 35.9-99.6), respectively, for GEI. In segment-level analysis, sensitivity and specificity for the detection of specific segment lesions were 62.5% (95% CI, 48.1-75) and 97.1% (95% CI, 93.5-98.7), respectively, for DWI and 45.7% (95% CI, 30.8-61.3) and 98.2% (95% CI, 95.3-99.4), respectively, for GEI. The sensitivity of DWI was significantly better than that of GEI per patient (p = 0.004) and per segment (p = 0.028). DWI demonstrates better performance than GEI for the detection of active lesions in children with IBD. Examination with no intravenous injection-DWI can replace T1 weighted images when paediatric patients are screened with MRE for IBD. Examination performed in free breathing is better tolerated by children.
Comparison of 3% sorbitol vs psyllium fibre as oral contrast agents in MR enterography
Saini, S; Colak, E; Anthwal, S; Vlachou, P A; Raikhlin, A
2014-01-01
Objective: To compare the degree of small bowel distension achieved by 3% sorbitol, a high osmolarity solution, and a psyllium-based bulk fibre as oral contrast agents (OCAs) in MR enterography (MRE). Methods: This retrospective study was approved by our institutional review board. A total of 45 consecutive normal MRE examinations (sorbitol, n = 20; psyllium, n = 25) were reviewed. The patients received either 1.5 l of 3% sorbitol or 2 l of 1.6 g kg−1 psyllium prior to imaging. Quantitative small bowel distension measurements were taken in five segments: proximal jejunum, distal jejunum, proximal ileum, distal ileum and terminal ileum by two independent radiologists. Distension in these five segments was also qualitatively graded from 0 (very poor) to 4 (excellent) by two additional independent radiologists. Statistical analysis comparing the groups and assessing agreement included intraclass coefficients, Student's t-test and Mann–Whitney U-test. Results: Small bowel distension was not significantly different in any of the five small bowel segments between the use of sorbitol and psyllium as OCAs in both the qualitative (p = 0.338–0.908) and quantitative assessments (p = 0.083–0.856). The mean bowel distension achieved was 20.1 ± 2.2 mm for sorbitol and 19.8 ± 2.5 mm for psyllium (p = 0.722). Visualization of the ileum was good or excellent in 65% of the examinations in both groups. Conclusion: Sorbitol and psyllium are not significantly different at distending the small bowel and both may be used as OCAs for MRE studies. Advances in knowledge: This is the first study to directly compare the degree of distension in MRE between these two common, readily available and inexpensive OCAs. PMID:25062448
Magnetic Resonance Enterography to Assess Multifocal and Multicentric Bowel Endometriosis.
Nyangoh Timoh, Krystel; Stewart, Zelda; Benjoar, Mikhael; Beldjord, Selma; Ballester, Marcos; Bazot, Marc; Thomassin-Naggara, Isabelle; Darai, Emile
To prospectively determine the accuracy of magnetic resonance enterography (MRE) compared with conventional magnetic resonance imaging (MRI) for multifocal (i.e., multiple lesions affecting the same digestive segment) and multicentric (i.e., multiple lesions affecting several digestive segments) bowel endometriosis. A prospective study (Canadian Task Force classification II-2). Tenon University Hospital, Paris, France. Patients with MRI-suspected colorectal endometriosis scheduled for colorectal resection from April 2014 to February 2016 were included. Patients underwent both 1.5-Tesla MRI and MRE as well as laparoscopically assisted and open colorectal resections. The diagnostic performance of MRI and MRE was evaluated for sensitivity, specificity, positive and negative predictive values, accuracy, and positive and negative likelihood ratios (LRs). The interobserver variability of the experienced and junior radiologists was quantified using weighted statistics. Forty-seven patients were included. Twenty-two (46.8%) patients had unifocal lesions, 14 (30%) had multifocal lesions, and 11 (23.4%) had multicentric lesions. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multifocal lesions were 0.29 (6/21), 1.00 (23/24), 15.36, and 0.71 for MRI and 0.57 (12/21), 0.89 (23/25), 4.95, and 0.58 for MRE. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multicentric lesions were 0.18 (1/11), 1.00 (1/1), 15, and 0.80 for MRI and 0.46 (5/11), 0.92 (33/36), 5.45, and 0.60 for MRE. Lower accuracies for MRI compared with MRE to diagnose multicentric (p = .01) and multifocal lesions (p = .004) were noted. The interobserver agreement for MRE was good for both multifocality (κ = 0.80) and multicentricity (κ = 0.61). MRE has better accuracy for diagnosing multifocal and multicentric bowel endometriosis than conventional MRI. Copyright © 2018. Published by Elsevier Inc.
A comprehensive review and update on Crohn's disease.
Gajendran, Mahesh; Loganathan, Priyadarshini; Catinella, Anthony P; Hashash, Jana G
2018-02-01
The term inflammatory bowel disease (IBD) refers principally to two major categories of chronic relapsing inflammatory intestinal disorders: Crohn's disease (CD) and ulcerative colitis (UC). In the United States, it is currently estimated that about 1.5 million people suffer from IBD, causing considerable suffering, mortality and economic loss every year. Yet the cause of IBD is unknown, and until we understand more, prevention or cure will not be possible. There is a lot of variation in the incidence and prevalence of CD based on geographic region, environment, immigrant population, and ethnic groups. The annual incidence of CD in North America is reported to be 3.1-20.2 per 100,000 with a prevalence of 201 per 100,000 population. Based on the epidemiological, genetic and immunological data, CD is considered to be a heterogeneous disorder with multifactorial etiology in which genetics and environment interact to manifest the disease. Several genes have been studied so for with respect to CD, but thus far the strong and replicated associations have been identified with NOD2, IL23R and ATG16L1 genes. The risk factors implicated with CD include smoking, low fiber- high carbohydrate diet, altered microbiome and medications such as non-steroidal anti-inflammatory drugs. CD is typically characterized by transmural inflammation of the intestine and could affect any part of the gastrointestinal tract from mouth to perianal area. In terms of distribution of the disease 25% of the patients have colitis only, 25% is ileitis only and 50% have ileocolitis. The Montreal classification is based on the age at diagnosis (<16, 17-40, > 40), disease location (Ileal, colonic, Ileocolonic) and the disease behavior (nonstricturing/nonpenetrating, stricturing, penetrating). The key features for diagnosing CD comprises a combination of radiographic, endoscopic and pathological findings demonstrating focal, asymmetric, transmural or granulomatous features. Abdominal Computed tomography (CT) enterography is the most preferred first-line radiologic study used in the assessment of small bowel CD. The diagnostic accuracy of magnetic resonance enterography/enteroclysis is similar to that of CT scans and also prevents exposure to ionizing radiation. Endoscopic scores are considered to be the gold standard tool to measure the activity of CD and they are used more commonly in the clinical trials to measure the efficacy of various drugs on inducing and maintaining mucosal healing. The most common scoring systems used to measure clinical disease activity include Crohn's Disease Activity Index (CDAI), HBI- Harvey-Bradshaw index (HBI), short inflammatory bowel disease questionnaire (SIBDQ) and Lehmann score. Management of Crohn's disease has been seen as an evolving challenge owing to its widely heterogeneous manifestations, overlapping characteristics with other inflammatory disorders, often elusive extraintestinal manifestations and uncertain etiology. Therapeutic interventions are tailored to address symptomatic response and subsequent tolerance of the intervention. Chronology of treatment should favor treatment dose acute disease or "induction therapy", followed by maintenance of adequate response or remission, i.e. "maintenance therapy". The medications which are highly effective in inducing remission include steroids and Tumor Necrosis Factor (TNF) inhibitors. Medications used to maintain remission include 5-aminosalicyclic acid products, immunomodulators (Azathioprine, 6-mercaptopurine, methotrexate) and TNF inhibitors (infliximab, adalimumab, certolizumab and golimumab). Surgical interventions like bowel resection, stricturoplasty or drainage of abscess is required in up to two thirds of CD patients during their lifetime. The most common indications for surgical resection are medically refractory disease, perforation, persisting or recurrent obstruction, abscess not amenable to percutaneous drainage, intractable hemorrhage, dysplasia or cancer. Endoscopic recurrence in postoperative CD patients, as defined by Rutgeers score i2-i4 occur in 30-90% of the patients at the neoterminal ileum within 12 months of surgery and almost universally by 5 years. Treating CD requires a comprehensive care team including the patient, primary care provider, and gastroenterologist. In summary CD is a chronic inflammatory condition with a remitting and relapsing course primarily affecting relatively younger population with significant socioeconomic effects. Copyright © 2018 Mosby, Inc. All rights reserved.
A modified conjugate gradient method based on the Tikhonov system for computerized tomography (CT).
Wang, Qi; Wang, Huaxiang
2011-04-01
During the past few decades, computerized tomography (CT) was widely used for non-destructive testing (NDT) and non-destructive examination (NDE) in the industrial area because of its characteristics of non-invasiveness and visibility. Recently, CT technology has been applied to multi-phase flow measurement. Using the principle of radiation attenuation measurements along different directions through the investigated object with a special reconstruction algorithm, cross-sectional information of the scanned object can be worked out. It is a typical inverse problem and has always been a challenge for its nonlinearity and ill-conditions. The Tikhonov regulation method is widely used for similar ill-posed problems. However, the conventional Tikhonov method does not provide reconstructions with qualities good enough, the relative errors between the reconstructed images and the real distribution should be further reduced. In this paper, a modified conjugate gradient (CG) method is applied to a Tikhonov system (MCGT method) for reconstructing CT images. The computational load is dominated by the number of independent measurements m, and a preconditioner is imported to lower the condition number of the Tikhonov system. Both simulation and experiment results indicate that the proposed method can reduce the computational time and improve the quality of image reconstruction. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
Fischer, J A; Muff, R; Born, W
2002-08-01
The calcitonin (CT) receptor (CTR) and the CTR-like receptor (CRLR) are close relatives within the type II family of G-protein-coupled receptors, demonstrating sequence identity of 50%. Unlike the interaction between CT and CTR, receptors for the related hormones and neuropeptides amylin, CT-gene-related peptide (CGRP) and adrenomedullin (AM) require one of three accessory receptor-activity-modifying proteins (RAMPs) for ligand recognition. An amylin/CGRP receptor is revealed when CTR is co-expressed with RAMP1. When complexed with RAMP3, CTR interacts with amylin alone. CRLR, initially classed as an orphan receptor, is a CGRP receptor when co-expressed with RAMP1. The same receptor is specific for AM in the presence of RAMP2. Together with human RAMP3, CRLR defines an AM receptor, and with mouse RAMP3 it is a low-affinity CGRP/AM receptor. CTR-RAMP1, antagonized preferentially by salmon CT-(8-32) and not by CGRP-(8-37), and CRLR-RAMP1, antagonized by CGRP-(8-37), are two CGRP receptor isotypes. Thus amylin and CGRP interact specifically with heterodimeric complexes between CTR and RAMP1 or RAMP3, and CGRP and AM interact with complexes between CRLR and RAMP1, RAMP2 or RAMP3.
Naegleria fowleri immunization modifies lymphocytes and APC of nasal mucosa.
Carrasco-Yepez, M M; Campos-Rodríguez, R; Reséndiz-Albor, A A; Peña-Juárez, C; Contis-Montes de Oca, A; Arciniega-Martínez, I M; Bonilla-Lemus, P; Rojas-Hernandez, S
2018-03-01
We investigated whether intranasal immunization with amoebic lysates plus cholera toxin modified the populations of T and B lymphocytes, macrophages and dendritic cells by flow cytometry from nose-associated lymphoid tissue (NALT), cervical lymph nodes (CN), nasal passages (NP) and spleen (SP). In all immunized groups, the percentage of CD4 was higher than CD8 cells. CD45 was increased in B cells from mice immunized. We observed IgA antibody-forming cell (IgA-AFC) response, mainly in NALT and NP. Macrophages from NP and CN expressed the highest levels of CD80 and CD86 in N. fowleri lysates with either CT or CT alone immunized mice, whereas dendritic cells expressed high levels of CD80 and CD86 in all compartment from immunized mice. These were lower than those expressed by macrophages. Only in SP from CT-immunized mice, these costimulatory molecules were increased. These results suggest that N. fowleri and CT antigens are taking by APCs, and therefore, protective immunity depends on interactions between APCs and T cells from NP and CN. Consequently, CD4 cells stimulate the differentiation from B lymphocytes to AFC IgA-positive; antibody that we previously found interacting with trophozoites in the nasal lumen avoiding the N. fowleri attachment to nasal epithelium. © 2017 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu; Brinkmann, Debra H.; Ward, Shelly B.
2013-03-15
Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the secondmore » (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.« less
Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A
2013-03-15
This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.
Effect of TiO2 modification with amino-based self-assembled monolayer on inverted organic solar cell
NASA Astrophysics Data System (ADS)
Tozlu, Cem; Mutlu, Adem; Can, Mustafa; Havare, Ali Kemal; Demic, Serafettin; Icli, Sıddık
2017-11-01
The effects of surface modification of titanium dioxide (TiO2) on the performance of inverted type organic solar cells (i-OSCs) was investigated in this study. A series of benzoic acid derivatized self-assembled monolayer (SAM) molecules of 4‧-[(hexyloxy)phenyl]amino-3,5-biphenyl dicarboxylic acid (CT17) and 4‧-[1-naphthyl (phenyl)amino]biphenyl-4-carboxylic acid (CT19) were utilized to modify the interface between TiO2 buffer layer and poly-3 hexylthiophene (P3HT):[6,6]-phenyl C61 butyric acid methyl ester (PC61BM) active layer having the device structure of ITO/TiO2/SAM/P3HT:PC61BM/MoO3/Ag. The work function and surface wetting properties of TiO2 buffer layer served as electron transporting layer between ITO and PC61BM active layer were tuned by SAM method. The solar cell of the SAM modified devices exhibited better performance. The power conversion efficiency (PCE) of i-OSCs devices with bare TiO2 electrodes enhanced from 2.00% to 2.21% and 2.43% with CT17 and CT19 treated TiO2 electrodes, respectively. The open circuit voltage (Voc) of the SAM treated TiO2 devices reached to 0.60 V and 0.61 V, respectively, while the Voc of untreated TiO2 was 0.57 V. The water contact angle of i-OSCs with CT17 and CT19 SAMs was also higher than the value of the unmodified TiO2 electrode. These results show that inserting a monolayer at the interface between organic and inorganic layers is an useful alternative method to improve the performance of i-OSCs.
Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram
NASA Astrophysics Data System (ADS)
Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.
2015-11-01
The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.
Development of a repetitive compact torus injector
NASA Astrophysics Data System (ADS)
Onchi, Takumi; McColl, David; Dreval, Mykola; Rohollahi, Akbar; Xiao, Chijin; Hirose, Akira; Zushi, Hideki
2013-10-01
A system for Repetitive Compact Torus Injection (RCTI) has been developed at the University of Saskatchewan. CTI is a promising fuelling technology to directly fuel the core region of tokamak reactors. In addition to fuelling, CTI has also the potential for (a) optimization of density profile and thus bootstrap current and (b) momentum injection. For steady-state reactor operation, RCTI is necessary. The approach to RCTI is to charge a storage capacitor bank with a large capacitance and quickly charge the CT capacitor bank through a stack of integrated-gate bipolar transistors (IGBTs). When the CT bank is fully charged, the IGBT stack will be turned off to isolate banks, and CT formation/acceleration sequence will start. After formation of each CT, the fast bank will be replenished and a new CT will be formed and accelerated. Circuits for the formation and the acceleration in University of Saskatchewan CT Injector (USCTI) have been modified. Three CT shots at 10 Hz or eight shots at 1.7 Hz have been achieved. This work has been sponsored by the CRC and NSERC, Canada.
Roman-Blas, Jorge A; Mediero, Aránzazu; Tardío, Lidia; Portal-Nuñez, Sergio; Gratal, Paula; Herrero-Beaumont, Gabriel; Largo, Raquel
2017-01-05
Osteoarthritis is the most common chronic joint disorder especially during aging. Although with controversies, glucosamine, both in its forms of sulfate and hydrochloride, and chondroitin sulfate are commonly employed to treat osteoarthritis. Due to the modest improve in the symptoms observed in patients treated with these drugs alone, a formulation combining both agents has been considered. The discrepant results achieved for pain control or structural improvement in osteoarthritis patients has been attributed to the quality of chemical formulations or different bias in clinical studies. The current study has been designed to test the effects of two different combined formulations with adequate pharmaceutical grade of these drugs in osteoarthritic joints, and to explore the underlying mechanisms modulated by both formulations in different osteoarthritis target tissues. Knee osteoarthritis was surgically induced in experimental rabbits. Some animals received the combined therapy (CT)1, (chondroitin sulfate 1200mg/day + glucosamine sulfate 1500mg/day), or the CT2 ((chondroitin sulfate 1200mg/day + glucosamine hydrochloride 1500mg/day). Neither CT1 nor CT2 significantly modified the cartilage damage or the synovial inflammation observed in osteoarthritic animals. Treatments were also unable to modify the presence of pro-inflammatory mediators, and the synthesis of metalloproteinases in the cartilage or in the synovium of osteoarthritic animals. Combined therapies did not modify the decrease in the subchondral bone mineral density observed in osteoarthritic rabbits. Therapies of chondroitin sulfate plus glucosamine sulfate or chondroitin sulfate plus glucosamine hydrochloride failed to improve structural damage or to ameliorate the inflammatory profile of joint tissues during experimental osteoarthritis. Published by Elsevier B.V.
Body-wide anatomy recognition in PET/CT images
NASA Astrophysics Data System (ADS)
Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.
2015-03-01
With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.
Al-Hablani, Bader
2017-01-01
The objective of this study is to discuss and analyze the use of automated SNOMED CT clinical coding in clinical decision support systems (CDSSs) for preventive care. The central question that this study seeks to answer is whether the utilization of SNOMED CT in CDSSs can improve preventive care. PubMed, Google Scholar, and Cochrane Library were searched for articles published in English between 2001 and 2012 on SNOMED CT, CDSS, and preventive care. Outcome measures were the sensitivity or specificity of SNOMED CT coded data and the positive predictive value or negative predictive value of SNOMED CT coded data. Additionally, we documented the publication year, research question, study design, results, and conclusions of these studies. The reviewed studies suggested that SNOMED CT successfully represents clinical terms and negated clinical terms. The use of SNOMED CT in CDSS can be considered to provide an answer to the problem of medical errors as well as for preventive care in general. Enhancement of the modifiers and synonyms found in SNOMED CT will be necessary to improve the expected outcome of the integration of SNOMED CT with CDSS. Moreover, the application of the tree-augmented naïve (TAN) Bayesian network method can be considered the best technique to search SNOMED CT data and, consequently, to help improve preventive health services.
Al-Hablani, Bader
2017-01-01
Objective The objective of this study is to discuss and analyze the use of automated SNOMED CT clinical coding in clinical decision support systems (CDSSs) for preventive care. The central question that this study seeks to answer is whether the utilization of SNOMED CT in CDSSs can improve preventive care. Method PubMed, Google Scholar, and Cochrane Library were searched for articles published in English between 2001 and 2012 on SNOMED CT, CDSS, and preventive care. Outcome Measures Outcome measures were the sensitivity or specificity of SNOMED CT coded data and the positive predictive value or negative predictive value of SNOMED CT coded data. Additionally, we documented the publication year, research question, study design, results, and conclusions of these studies. Results The reviewed studies suggested that SNOMED CT successfully represents clinical terms and negated clinical terms. Conclusion The use of SNOMED CT in CDSS can be considered to provide an answer to the problem of medical errors as well as for preventive care in general. Enhancement of the modifiers and synonyms found in SNOMED CT will be necessary to improve the expected outcome of the integration of SNOMED CT with CDSS. Moreover, the application of the tree-augmented naïve (TAN) Bayesian network method can be considered the best technique to search SNOMED CT data and, consequently, to help improve preventive health services. PMID:28566995
NASA Astrophysics Data System (ADS)
Mahmud, M. H.; Nordin, A. J.; Saad, F. F. Ahmad; Fattah Azman, A. Z.
2014-11-01
This study aims to estimate the radiation effective dose resulting from whole body fluorine-18 flourodeoxyglucose Positron Emission Tomography (18F-FDG PET) scanning as compared to conservative Computed Tomography (CT) techniques in evaluating oncology patients. We reviewed 19 oncology patients who underwent 18F-FDG PET/CT at our centre for cancer staging. Internal and external doses were estimated using radioactivity of injected FDG and volume CT Dose Index (CTDIvol), respectively with employment of the published and modified dose coefficients. The median differences of dose among the conservative CT and PET protocols were determined using Kruskal Wallis test with p < 0.05 considered as significant. The median (interquartile range, IQR) effective doses of non-contrasted CT, contrasted CT and PET scanning protocols were 7.50 (9.35) mSv, 9.76 (3.67) mSv and 6.30 (1.20) mSv, respectively, resulting in the total dose of 21.46 (8.58) mSv. Statistically significant difference was observed in the median effective dose between the three protocols (p < 0.01). The effective doses of whole body 18F-FDG PET technique may be effective the lowest amongst the conventional CT imaging techniques.
Interaction between a cationic porphyrin and ctDNA investigated by SPR, CV and UV-vis spectroscopy.
Xu, Zi-Qiang; Zhou, Bo; Jiang, Feng-Lei; Dai, Jie; Liu, Yi
2013-10-01
The interaction between ctDNA and a cationic porphyrin was studied in this work. The binding process was monitored by surface plasmon resonance (SPR) spectroscopy in detail. The association, dissociation rate constants and the binding constants calculated by global analysis were 2.4×10(2)±26.4M(-1)s(-1), 0.011±0.0000056s(-1) and 2.18×10(4)M(-1), respectively. And the results were confirmed by cyclic voltammetry and UV-vis absorption spectroscopy. The binding constants obtained from cyclic voltammetry and UV-vis absorption spectroscopy were 8.28×10(4)M(-1) and 6.73×10(4)M(-1) at 298K, respectively. The covalent immobilization methodology of ctDNA onto gold surface modified with three different compounds was also investigated by SPR. These compounds all contain sulfydryl but with different terminated functional groups. The results indicated that the 11-MUA (HS(CH2)10COOH)-modified gold film is more suitable for studying the DNA-drug interaction. Copyright © 2013 Elsevier B.V. All rights reserved.
Oxygen-dependent acetylation and dimerization of the corepressor CtBP2 in neural stem cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karaca, Esra; Lewicki, Jakub; Hermanson, Ola, E-mail: Ola.Hermanson@ki.se
2015-03-01
The transcriptional corepressor CtBP2 is essential for proper development of the nervous system. The factor exerts its repression by interacting in complexes with chromatin-modifying factors such as histone deacetylases (HDAC) 1/2 and the histone demethylase LSD1/KDM1. Notably, the histone acetyl transferase p300 acetylates CtBP2 and this is an important regulatory event of the activity and subcellular localization of the protein. We recently demonstrated an essential role for CtBPs as sensors of microenvironmental oxygen levels influencing the differentiation potential of neural stem cells (NSCs), but it is not known whether oxygen levels influence the acetylation levels of CtBP factors. Here wemore » show by using proximity ligation assay (PLA) that CtBP2 acetylation levels increased significantly in undifferentiated, proliferating NSCs under hypoxic conditions. CtBP2 interacted with the class III HDAC Sirt1 but this interaction was unaltered in hypoxic conditions, and treatment with the Sirt1 inhibitor Ex527 did not result in any significant change in total CtBP2 acetylation levels. Instead, we revealed a significant decrease in PLA signal representing CtBP2 dimerization in NSCs under hypoxic conditions, negatively correlating with the acetylation levels. Our results suggest that microenvironmental oxygen levels influence the dimerization and acetylation levels, and thereby the activity, of CtBP2 in proliferating NSCs.« less
Performance evaluations of demons and free form deformation algorithms for the liver region.
Wang, Hui; Gong, Guanzhong; Wang, Hongjun; Li, Dengwang; Yin, Yong; Lu, Jie
2014-04-01
We investigated the influence of breathing motion on radiation therapy according to four- dimensional computed tomography (4D-CT) technology and indicated the registration of 4D-CT images was significant. The demons algorithm in two interpolation modes was compared to the FFD model algorithm to register the different phase images of 4D-CT in tumor tracking, using iodipin as verification. Linear interpolation was used in both mode 1 and mode 2. Mode 1 set outside pixels to nearest pixel, while mode 2 set outside pixels to zero. We used normalized mutual information (NMI), sum of squared differences, modified Hausdorff-distance, and registration speed to evaluate the performance of each algorithm. The average NMI after demons registration method in mode 1 improved 1.76% and 4.75% when compared to mode 2 and FFD model algorithm, respectively. Further, the modified Hausdorff-distance was no different between demons modes 1 and 2, but mode 1 was 15.2% lower than FFD. Finally, demons algorithm has the absolute advantage in registration speed. The demons algorithm in mode 1 was therefore found to be much more suitable for the registration of 4D-CT images. The subtractions of floating images and reference image before and after registration by demons further verified that influence of breathing motion cannot be ignored and the demons registration method is feasible.
NASA Astrophysics Data System (ADS)
Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance
2017-04-01
Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, ChuanXiang; Zhao, Yi, E-mail: yizhao@xmu.edu.cn, E-mail: liangwz@xmu.edu.cn; Liang, WanZhen, E-mail: yizhao@xmu.edu.cn, E-mail: liangwz@xmu.edu.cn
2015-10-21
The time-dependent correlation function approach for the calculations of absorption and resonance Raman spectra (RRS) of organic molecules absorbed on semiconductor surfaces [Y. Zhao and W. Z. Liang, J. Chem. Phys. 135, 044108 (2011)] is extended to include the contribution of the intermolecular charge transfer (CT) excitation from the absorbers to the semiconducting nanoparticles. The results demonstrate that the bidirectionally interfacial CT significantly modifies the spectral line shapes. Although the intermolecular CT excitation makes the absorption spectra red shift slightly, it essentially changes the relative intensities of mode-specific RRS and causes the oscillation behavior of surface enhanced Raman spectra withmore » respect to interfacial electronic couplings. Furthermore, the constructive and destructive interferences of RRS from the localized molecular excitation and CT excitation are observed with respect to the electronic coupling and the bottom position of conductor band. The interferences are determined by both excitation pathways and bidirectionally interfacial CT.« less
Local reconstruction in computed tomography of diffraction enhanced imaging
NASA Astrophysics Data System (ADS)
Huang, Zhi-Feng; Zhang, Li; Kang, Ke-Jun; Chen, Zhi-Qiang; Zhu, Pei-Ping; Yuan, Qing-Xi; Huang, Wan-Xia
2007-07-01
Computed tomography of diffraction enhanced imaging (DEI-CT) based on synchrotron radiation source has extremely high sensitivity of weakly absorbing low-Z samples in medical and biological fields. The authors propose a modified backprojection filtration(BPF)-type algorithm based on PI-line segments to reconstruct region of interest from truncated refraction-angle projection data in DEI-CT. The distribution of refractive index decrement in the sample can be directly estimated from its reconstruction images, which has been proved by experiments at the Beijing Synchrotron Radiation Facility. The algorithm paves the way for local reconstruction of large-size samples by the use of DEI-CT with small field of view based on synchrotron radiation source.
CT reconstruction from portal images acquired during volumetric-modulated arc therapy
NASA Astrophysics Data System (ADS)
Poludniowski, G.; Thomas, M. D. R.; Evans, P. M.; Webb, S.
2010-10-01
Volumetric-modulated arc therapy (VMAT), a form of intensity-modulated arc therapy (IMAT), has become a topic of research and clinical activity in recent years. As a form of arc therapy, portal images acquired during the treatment fraction form a (partial) Radon transform of the patient. We show that these portal images, when used in a modified global cone-beam filtered backprojection (FBP) algorithm, allow a surprisingly recognizable CT-volume to be reconstructed. The possibility of distinguishing anatomy in such VMAT-CT reconstructions suggests that this could prove to be a valuable treatment position-verification tool. Further, some potential for local-tomography techniques to improve image quality is shown.
Software platform for simulation of a prototype proton CT scanner.
Giacometti, Valentina; Bashkirov, Vladimir A; Piersimoni, Pierluigi; Guatelli, Susanna; Plautz, Tia E; Sadrozinski, Hartmut F-W; Johnson, Robert P; Zatserklyaniy, Andriy; Tessonnier, Thomas; Parodi, Katia; Rosenfeld, Anatoly B; Schulte, Reinhard W
2017-03-01
Proton computed tomography (pCT) is a promising imaging technique to substitute or at least complement x-ray CT for more accurate proton therapy treatment planning as it allows calculating directly proton relative stopping power from proton energy loss measurements. A proton CT scanner with a silicon-based particle tracking system and a five-stage scintillating energy detector has been completed. In parallel a modular software platform was developed to characterize the performance of the proposed pCT. The modular pCT software platform consists of (1) a Geant4-based simulation modeling the Loma Linda proton therapy beam line and the prototype proton CT scanner, (2) water equivalent path length (WEPL) calibration of the scintillating energy detector, and (3) image reconstruction algorithm for the reconstruction of the relative stopping power (RSP) of the scanned object. In this work, each component of the modular pCT software platform is described and validated with respect to experimental data and benchmarked against theoretical predictions. In particular, the RSP reconstruction was validated with both experimental scans, water column measurements, and theoretical calculations. The results show that the pCT software platform accurately reproduces the performance of the existing prototype pCT scanner with a RSP agreement between experimental and simulated values to better than 1.5%. The validated platform is a versatile tool for clinical proton CT performance and application studies in a virtual setting. The platform is flexible and can be modified to simulate not yet existing versions of pCT scanners and higher proton energies than those currently clinically available. © 2017 American Association of Physicists in Medicine.
2012-04-01
ER D C/ G SL T R -1 2 -1 5 Pavement -Transportation Computer Assisted Structural Engineering (PCASE) Implementation of the Modified...Berggren (ModBerg) Equation for Computing the Frost Penetration Depth within Pavement Structures G eo te ch n ic al a n d S tr u ct u re s La b or at...April 2012 Pavement -Transportation Computer Assisted Structural Engineering (PCASE) Implementation of the Modified Berggren (ModBerg) Equation for
Lee, Jae Seung; Lee, Sang-Min; Seo, Joon Beom; Lee, Sei Won; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do
2014-01-01
Published data concerning the utility of computed tomography (CT)-based lung volumes are limited to correlation with lung function. The aim of this study was to evaluate the clinical utility of the CT expiratory-to-inspiratory lung volume ratio (CT Vratio) by assessing the relationship with clinically relevant outcomes. A total of 75 stable chronic obstructive pulmonary disease (COPD) patients having pulmonary function testing and volumetric CT at full inspiration and expiration were retrospectively evaluated. Inspiratory and expiratory CT lung volumes were measured using in-house software. Correlation of the CT Vratio with patient-centered outcomes, including the modified Medical Research Council (MMRC) dyspnea score, the 6-min walk distance (6MWD), the St. George's Respiratory Questionnaire (SGRQ) score, and multidimensional COPD severity indices, such as the BMI, airflow obstruction, dyspnea, and exercise capacity index (BODE) and age, dyspnea, and airflow obstruction (ADO), were analyzed. The CT Vratio correlated significantly with BMI (r = -0.528, p < 0.001). The CT Vratio was also significantly associated with MMRC dyspnea (r = 0.387, p = 0.001), 6MWD (r = -0.459, p < 0.001), and SGRQ (r = 0.369, p = 0.001) scores. Finally, the CT Vratio had significant correlations with the BODE and ADO multidimensional COPD severity indices (r = 0.605, p < 0.001; r = 0.411, p < 0.001). The CT Vratio had significant correlations with patient-centered outcomes and multidimensional COPD severity indices. © 2013 S. Karger AG, Basel.
Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.
Meshaal, Marwa Sayed; Kassem, Hussein Heshmat; Samir, Ahmad; Zakaria, Ayman; Baghdady, Yasser; Rizk, Hussein Hassan
2015-01-01
Infective endocarditis (IE) is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs). These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA) is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE. From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention. The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%). Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32%) had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%). The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture. Routine brain CT/CTA resulted in changes in the treatment plan in a significant proportion of patients with IE, even those without clinically evident neurological disease. Routine brain CT/CTA may be indicated in all hospitalized patients with IE.
Liang, Jibei; Cheng, Tao; Huang, Yi; Liu, Jianhua
2018-05-28
Enhanced bioremediation is a favorable approach for petroleum pollutant cleanup, which depends on the growth of oil-eating microorganisms. In this study, we show that, by using the modified T-RFLP (mT-RFLP) methodology, one of the four major microbial populations derived from oil sludge has failed to propagate in MS medium supplemented with 2% yeast extract (YE). rDNA sequence-based analysis indicated that the four populations were Donghicola sp. CT5, Bacillus sp. CT6, Alcaligenes sp. CT10, and Pseudomonas sp. ZS1. Four purified strains grow well individually in MS medium supplemented with 2% YE, suggesting that ZS1 growth is antagonized by other strains. Co-growth analysis using mT-RFLP methodology and plate inhibitory assay indicated that ZS1 exhibited antagonistic effect against CT5 and CT6. On the other hand, co-growth analysis and plate inhibition assay showed that CT10 antagonized against ZS1. To investigate the potential compounds responsible for the antagonism, supernatant of CT10 culture was subjected to GC-MS analysis. Analysis indicated that CT10 produced a number of antimicrobial compounds including cyclodipeptide c-(L-Pro-L-Phe), which was known to inhibit the growth of Pseudomonas sp. Growth test using the purified c-(L-Pro-L-Phe) from CT10 confirmed its inhibitory activity. We further showed that, using both gravimetric and GC analysis, CT10 antagonism against the oil-eating ZS1 led to the diminishing of crude oil degradation. Together, our results indicate that bioremediation can be affected by environmental antagonists.
Takayoshi, Kotoe; Kusaba, Hitoshi; Uenomachi, Masato; Mitsugi, Kenji; Makiyama, Chinatsu; Makiyama, Akitaka; Uchino, Keita; Shirakawa, Tsuyoshi; Shibata, Yoshihiro; Shinohara, Yudai; Inadomi, Kyoko; Tsuchihashi, Kenji; Arita, Shuji; Ariyama, Hiroshi; Esaki, Taito; Akashi, Koichi; Baba, Eishi
2017-08-01
Standard therapy for advanced small bowel adenocarcinoma (SBA) has not yet been established. The present study assessed the efficacy and safety of chemotherapy (CT) in association with molecular targeting approaches for SBA. The histories of 33 advanced SBA patients from six different institutions in Japan, who received CT from 2008 to 2016, were retrospectively examined for background, clinical course and outcome. Median patient age was 65 years (range 39-83). Primary tumor was located in the duodenum in 21 patients (67%), the ampulla of Vater in three patients (9%), the jejunum in seven patients (21%) and the ileum in one patient (3%). Histologically, well-to-moderately and poorly differentiated adenocarcinoma were identified in 20 (61%) and nine (27%) patients, respectively. Thirteen patients received a single CT regimen, seven patients received two types of CT regimen, and 13 patients received three or more CT regimens. As first-line CT, modified FOLFOX6, capecitabine plus oxaliplatin, and S-1 plus cisplatin were employed in 13, 1, and 4 patients, respectively. The response rate (RR) and median progression-free survival (PFS) were 25% and 6.0 months, respectively. Median overall survival (OS) was 13.0 months. Nine out of the 33 patients received bevacizumab-containing CT and three received cetuximab-containing CT. Median OS of bevacizumab-containing CT patients was 21.9 months. No unexpected serious adverse events were observed. The analysis indicates that combination CT for advanced SBA is associated with modest efficacy and safety, and bevacizumab-containing CT may contribute to favorable outcome in these patients.
Allaire, Brett T; DePaolis Kaluza, M Clara; Bruno, Alexander G; Samelson, Elizabeth J; Kiel, Douglas P; Anderson, Dennis E; Bouxsein, Mary L
2017-01-01
Current standard methods to quantify disc height, namely distortion compensated Roentgen analysis (DCRA), have been mostly utilized in the lumbar and cervical spine and have strict exclusion criteria. Specifically, discs adjacent to a vertebral fracture are excluded from measurement, thus limiting the use of DCRA in studies that include older populations with a high prevalence of vertebral fractures. Thus, we developed and tested a modified DCRA algorithm that does not depend on vertebral shape. Participants included 1186 men and women from the Framingham Heart Study Offspring and Third Generation Multidetector CT Study. Lateral CT scout images were used to place 6 morphometry points around each vertebra at 13 vertebral levels in each participant. Disc heights were calculated utilizing these morphometry points using DCRA methodology and our modified version of DCRA, which requires information from fewer morphometry points than the standard DCRA. Modified DCRA and standard DCRA measures of disc height are highly correlated, with concordance correlation coefficients above 0.999. Both measures demonstrate good inter- and intra-operator reproducibility. 13.9 % of available disc heights were not evaluable or excluded using the standard DCRA algorithm, while only 3.3 % of disc heights were not evaluable using our modified DCRA algorithm. Using our modified DCRA algorithm, it is not necessary to exclude vertebrae with fracture or other deformity from disc height measurements as in the standard DCRA. Modified DCRA also yields identical measurements to the standard DCRA. Thus, the use of modified DCRA for quantitative assessment of disc height will lead to less missing data without any loss of accuracy, making it a preferred alternative to the current standard methodology.
Badiga, Suguna; Johanning, Gary L.; Macaluso, Maurizio; Azuero, Andres; Chambers, Michelle M.; Siddiqui, Nuzhat R.; Piyathilake, Chandrika J.
2014-01-01
Background Studies in populations unexposed to folic acid (FA) fortification have demonstrated that MTHFR C677T polymorphism is associated with increased risk of higher grades of cervical intraepithelial neoplasia (CIN 2+). However, it is unknown whether exposure to higher folate as a result of the FA fortification program has altered the association between MTHFR C677T and risk of CIN, or the mechanisms involved with such alterations. The current study investigated the following in a FA fortified population: 1) The association between MTHFR C677T polymorphism and risk of CIN 2+; 2) The modifying effects of plasma folate concentrations on this association; and 3) The modifying effects of plasma folate on the association between the polymorphism and degree of methylation of long interspersed nucleotide elements (L1s), in peripheral blood mononuclear cell (PBMC) DNA, a documented biomarker of CIN risk. Methods The study included 457 US women diagnosed with either CIN 2+ (cases) or ≤ CIN 1 (non-cases). Unconditional logistic regression models were used to test the associations after adjusting for relevant risk factors for CIN. Results The 677CT/TT MTHFR genotypes were not associated with the risk of CIN 2+. Women with CT/TT genotype with lower folate, however, were more likely to be diagnosed with CIN 2+ compared to women with CT/TT genotype with higher folate (OR = 2.41, P = 0.030). Women with CT/TT genotype with lower folate were less likely to have a higher degree of PBMC L1 methylation compared to women with CT/TT genotype with higher folate (OR = 0.28, P = 0.017). Conclusions This study provides the first evidence that the MTHFR 677CT/TT genotype-associated lower degree of PBMC L1 methylation increases the risk of CIN 2+ in women in the US post-FA fortification era. Thus, even in the post-FA fortification era, not all women have adequate folate status to overcome MTHFR 677CT/TT genotype-associated lower degree of L1 methylation. PMID:25302494
Lee, Sang-Min; Hay, Debbie L; Pioszak, Augen A
2016-04-15
Receptor activity-modifying proteins (RAMP1-3) determine the selectivity of the class B G protein-coupled calcitonin receptor (CTR) and the CTR-like receptor (CLR) for calcitonin (CT), amylin (Amy), calcitonin gene-related peptide (CGRP), and adrenomedullin (AM) peptides. RAMP1/2 alter CLR selectivity for CGRP/AM in part by RAMP1 Trp-84 or RAMP2 Glu-101 contacting the distinct CGRP/AM C-terminal residues. It is unclear whether RAMPs use a similar mechanism to modulate CTR affinity for CT and Amy, analogs of which are therapeutics for bone disorders and diabetes, respectively. Here, we reproduced the peptide selectivity of intact CTR, AMY1 (CTR·RAMP1), and AMY2 (CTR·RAMP2) receptors using purified CTR extracellular domain (ECD) and tethered RAMP1- and RAMP2-CTR ECD fusion proteins and antagonist peptides. All three proteins bound salmon calcitonin (sCT). Tethering RAMPs to CTR enhanced binding of rAmy, CGRP, and the AMY antagonist AC413. Peptide alanine-scanning mutagenesis and modeling of receptor-bound sCT and AC413 supported a shared non-helical CGRP-like conformation for their TN(T/V)G motif prior to the C terminus. After this motif, the peptides diverged; the sCT C-terminal Pro was crucial for receptor binding, whereas the AC413/rAmy C-terminal Tyr had little or no influence on binding. Accordingly, mutant RAMP1 W84A- and RAMP2 E101A-CTR ECD retained AC413/rAmy binding. ECD binding and cell-based signaling assays with antagonist sCT/AC413/rAmy variants with C-terminal residue swaps indicated that the C-terminal sCT/rAmy residue identity affects affinity more than selectivity. rAmy(8-37) Y37P exhibited enhanced antagonism of AMY1 while retaining selectivity. These results reveal unexpected differences in how RAMPs determine CTR and CLR peptide selectivity and support the hypothesis that RAMPs allosterically modulate CTR peptide affinity. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
NASA Astrophysics Data System (ADS)
Liu, Lin; Zhang, Xiangyi; Li, Wuchao; Sun, Haozhen; Lou, Yan; Zhang, Xingguo; Li, Fanzhu
2013-11-01
A novel drug carrier for brain delivery, maleimide-poly(ethyleneglycol)-poly(lactide) (maleimide-PEG-PLA) nanoparticles (NPs) conjugated with mouse-anti-rat monoclonal antibody OX26 (OX26-NPs), was developed and its brain delivery property was evaluated. The diblock copolymers of maleimide-PEG-PLA were synthesized and applied to α-cobrotoxin (αCT)-loaded NPs which were characterized by transmission electron micrograph imaging, Fourier-transform IR, and X-ray diffraction. The NPs encapsulating αCT had a round and vesicle-like shape with a mean diameter around 100 nm, and the OX26 had covalently conjugated to the surface of NPs. MTT studies in brain microvascular endothelial cells (BMEC) revealed a moderate decrease in the cell viability of αCT, when incorporated in OX26-NPs compared to free αCT in solution. A higher affinity of the OX26-αCT-NPs to the BMEC was shown in comparison to αCT-NPs. Then, OX26-αCT-NPs were intranasally (i.n.) administered to rats, and αCT in the periaqueductal gray was monitored for up to 480 min using microdialysis technique in free-moving rats, with i.n. αCT-NPs, i.n. OX26-αCT-NPs, intramuscular injection (i.m.) αCT-NPs, and i.m. OX26-αCT-NPs. The brain transport results showed that the corresponding absolute bioavailability ( F abs) of i.n. OX26-αCT-NPs were about 125 and 155 % with i.n. αCT-NPs and i.m. OX26-αCT-NPs, respectively, and it was found that both the C max and AUC of the four groups were as follows: i.n. OX26-αCT-NPs > i.n. αCT-NPs > i.m. OX26-αCT-NPs > i.m. αCT-NPs, while αCT solution, as control groups, could hardly enter the brain. These results indicated that OX26-NPs are promising carriers for peptide brain delivery.
Marwede, Dirk; Schulz, Thomas; Kahn, Thomas
2008-12-01
To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex. Report content was manually indexed by two radiologists in consensus in term categories of Anatomic Location, Finding, Modifier, Relationship, Image Quality, and Uncertainty. Descriptive statistics were used and differences between age groups and report types were tested for significance using Kruskal-Wallis and Mann-Whitney Test (significance level <0.05). From 363 terms extracted, 304 (84%) were found and 59 (16%) were not found in RadLex. Report indexing showed a mean of 16.2 encoded items per report and 3.2 Finding per report. Term categories most frequently encoded were Modifier (1,030 of 3,244, 31.8%), Anatomic Location (813, 25.1%), Relationship (702, 21.6%) and Finding (638, 19.7%). Frequency of indexed items per report was higher in older age groups, but no significant difference was found between first study and follow up study reports. Frequency of distinct findings per report increased with patient age (p < 0.05). RadLex already covers most terms present in thoracic CT reports based on a small sample analysis from one institution. Applications for report encoding need to be developed to validate the lexicon against a larger sample of reports and address the issue of automatic relationship encoding.
Refinements in modeling the passive properties of laryngeal soft tissue.
Hunter, Eric J; Titze, Ingo R
2007-07-01
The nonlinear viscoelastic passive properties of three canine intrinsic laryngeal muscles, the lateral cricoarytenoid (LCA), the posterior cricoarytenoid (PCA), and the interarytenoid (IA), were fit to the parameters of a modified Kelvin model. These properties were compared with those of the thyroarytenoid (TA) and cricothyroid (CT) muscles, as well as previously unpublished viscoelastic characteristics of the human vocal ligament. Passive parameters of the modified Kelvin model were summarized for the vocal ligament, mucosa, and all five laryngeal muscles. Results suggest that the LCA, PCA, and IA muscles are functionally different from the TA and CT muscles in their load-bearing capacity. Furthermore, the LCA, PCA, and IA have a much larger stress-strain hysteresis effect than has been previously reported for the TA and CT or the vocal ligament. The variation in this effect suggests that the connective tissue within the TA and CT muscles is somehow similar to the vocal ligament but different from the LCA, PCA, or IA muscles. Further demonstrating the potential significance of grouping tissues in the laryngeal system by functional groups in the laryngeal system was the unique finding that, over their working elongation range, the LCA and PCA were nearly as exponentially stiff as the vocal ligament. This paper was written in conjunction with an online technical report (http://www.ncvs.org/ncvs/library/tech) in which comprehensive muscle data and sensitivity analysis, as well as downloadable data files and computer scripts, are made available.
Prabhu, Sunil; Sullivan, Jennifer L; Betageri, Guru V
2002-01-01
The objective of our study was to compare the in vitro release kinetics of a sustained-release injectable microsphere formulation of the polypeptide drug, calcitonin (CT), to optimize the characteristics of drug release from poly-(lactide-co-glycolide) (PLGA) copolymer biodegradable microspheres. A modified solvent evaporation and double emulsion technique was used to prepare the microspheres. Release kinetic studies were carried out in silanized tubes and dialysis bags, whereby microspheres were suspended and incubated in phosphate buffered saline, sampled at fixed intervals, and analyzed for drug content using a modified Lowry protein assay procedure. An initial burst was observed whereby about 50% of the total dose of the drug was released from the microspheres within 24 hr and 75% within 3 days. This was followed by a period of slow release over a period of 3 weeks in which another 10-15% of drug was released. Drug release from the dialysis bags was more gradual, and 50% CT was released only after 4 days and 75% after 12 days of release. Scanning electron micrographs revealed spherical particles with channel-like structures and a porous surface after being suspended in an aqueous solution for 5 days. Differential scanning calorimetric studies revealed that CT was present as a mix of amorphous and crystalline forms within the microspheres. Overall, these studies demonstrated that sustained release of CT from PLGA microspheres over a 3-week period is feasible and that release of drug from dialysis bags was more predictable than from tubes.
Radmard, Amir Reza; Hashemi Taheri, Amir Pejman; Salehian Nik, Elham; Kooraki, Soheil; Kolahdoozan, Shadi; Mirminachi, Babak; Sotoudeh, Masoud; Ekhlasi, Golnaz; Malekzadeh, Reza; Shahbazkhani, Bijan
2017-10-01
To assess small bowel abnormalities on magnetic resonance enterography (MRE) in adult patients with nonresponsive celiac disease (CD) and investigate their associations with endoscopic, histopathologic, serologic, and genetic features. This prospective study was carried out between September 2012 and August 2013. After approval by the Ethics Committee of our institution, informed consent was acquired from all participants. Forty consecutive patients with nonresponsive CD, aged 17-76 years, underwent MRE using a 1.5T unit. Sequences included T 2 -HASTE, True-FISP, pre- and postcontrast VIBE to assess the quantitative (number of ileal and jejunal folds) and qualitative (fold pattern abnormalities, mural thickening, increased enhancement, bowel dilatation, or intussusception) measures. Endoscopic manifestations were categorized as normal/mild vs. severe. Histopathological results were divided into mild and severe. Genotyping of HLA-DQ2 and DQ8 was performed. Serum levels of tissue-transglutaminase, endomysial, and gliadin antibodies were also determined. Logistic regression analysis and receiver operating characteristic (ROC) curve were used. Twenty-nine (72.5%) cases showed abnormal MRE. Reversed jejunoileal fold pattern had significant association with severe endoscopic (odds ratio [OR] = 8.38, 95% confidence interval [CI] 1.73-40.5) and pathologic features (OR = 7.36, 95% CI 1.33-40.54). An increased number of ileal folds/inch was significantly associated with severe MARSH score and positive HLA-DQ8. (P < 0.001 and P = 0.026, respectively). Ileal fold number had the highest areas under the curve for prediction of severe endoscopic (AUC: 0.75, P = 0.009) and pathologic (AUC: 0.84, P < 0.001) findings and positive anti-transglutaminase antibody (AUC: 0.85, P = 0.027). Fold pattern reversal on MRE is highly associated with endoscopic and pathologic features of refractory celiac disease (RCD). Increased ileal folds showed higher correlation with endoscopic-pathologic features, HLA-DQ8, and anti-transglutaminase level. MRE might be more sensitive for detection of increased ileal folds in CD rather than reduction of duodenal and jejunal folds due to better distension of ileal loops. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:1096-1106. © 2017 International Society for Magnetic Resonance in Medicine.
Church, Peter C; Greer, Mary-Louise C; Cytter-Kuint, Ruth; Doria, Andrea S; Griffiths, Anne M; Turner, Dan; Walters, Thomas D; Feldman, Brian M
2017-05-01
Magnetic resonance enterography (MRE) is increasingly relied upon for noninvasive assessment of intestinal inflammation in Crohn disease. However very few studies have examined the diagnostic accuracy of individual MRE signs in children. We have created an MR-based multi-item measure of intestinal inflammation in children with Crohn disease - the Pediatric Inflammatory Crohn's MRE Index (PICMI). To inform item selection for this instrument, we explored the inter-rater agreement and diagnostic accuracy of individual MRE signs of inflammation in pediatric Crohn disease and compared our findings with the reference standards of the weighted Pediatric Crohn's Disease Activity Index (wPCDAI) and C-reactive protein (CRP). In this cross-sectional single-center study, MRE studies in 48 children with diagnosed Crohn disease (66% male, median age 15.5 years) were reviewed by two independent radiologists for the presence of 15 MRE signs of inflammation. Using kappa statistics we explored inter-rater agreement for each MRE sign across 10 anatomical segments of the gastrointestinal tract. We correlated MRE signs with the reference standards using correlation coefficients. Radiologists measured the length of inflamed bowel in each segment of the gastrointestinal tract. In each segment, MRE signs were scored as either binary (0-absent, 1-present), or ordinal (0-absent, 1-mild, 2-marked). These segmental scores were weighted by the length of involved bowel and were summed to produce a weighted score per patient for each MRE sign. Using a combination of wPCDAI≥12.5 and CRP≥5 to define active inflammation, we calculated area under the receiver operating characteristic curve (AUC) for each weighted MRE sign. Bowel wall enhancement, wall T2 hyperintensity, wall thickening and wall diffusion-weighted imaging (DWI) hyperintensity were most commonly identified. Inter-rater agreement was best for decreased motility and wall DWI hyperintensity (kappa≥0.64). Correlation between MRE signs and wPCDAI was higher than with CRP. AUC was highest (≥0.75) for ulcers, wall enhancement, wall thickening, wall T2 hyperintensity and wall DWI hyperintensity. Some MRE signs had good inter-rater agreement and AUC for detection of inflammation in children with Crohn disease.
Sahi, Kamaldeep Singh; Lee, Karen S; Moss, Alan; Yee, Eric; Allard, Felicia; Brook, Alexander; Mortele, Koenraad J
2015-11-01
The purpose of this study was to describe the MR enterography (MRE) appearance of inflammation of the ileoanal pouch after ileal pouch-anal anastomosis (IPAA) surgery and to correlate it with pouch endoscopic and histopathologic findings. All MRE studies performed between October 1, 2007, and September 30, 2013, for patients who had previously undergone IPAA (n = 54) were retrieved. After review of medical records, the patients who underwent MRE, pouch endoscopy, and biopsy within 90 days (14 men, 14 women; mean age, 42.2 years; range, 24-67 years) were selected for inclusion in the study. Two blinded MRI radiologists in consensus retrospectively evaluated MRE studies for multiple MRI features. Two MRI scores were then calculated: an active and a composite inflammation score. A gastroenterologist retrospectively reviewed the pouch endoscopic images, and a pathologist reviewed the slides; both of these investigators were blinded. Both MRI scores were correlated with the pouch endoscopic and histopathologic findings. The composite MRI score had strong positive correlation with the endoscopic score (r = 0.61; p = 0.0005) but weak positive correlation with the histopathologic score (r = 0.31; p = 0.10, not statistically significant). The active inflammation MRI score had moderate positive correlation with the endoscopic score (r = 0.57; p = 0.0017) and weak positive correlation with the histopathologic score (r = 0.20; p = 0.31, not statistically significant). An MRI score ≥ 4 indicated the best results, with sensitivity of 86%, specificity of 79%, positive predictive value of 80%, negative predictive value of 85%, and accuracy of 82% for pouch inflammation. A positive likelihood ratio of 4.00 and negative likelihood ratio of 0.18 were obtained. In patients who have undergone IPAA surgery, the MRE findings strongly correlate with the pouch endoscopic findings with high sensitivity and positive predictive value for pouch inflammation. Therefore, MRE is a useful noninvasive test performed without ionizing radiation that can be used to evaluate patients with clinical symptoms and possibly alleviate the need for endoscopy in a select patient population.
The health care provider will perform a physical exam, and ask about your medical history and symptoms. Tests that may be done include: Bronchoscopy with culture Complete blood count (CBC) Chest x-ray Chest CT scan Lung biopsy Modified AFB smear of sputum ...
Mainenti, Pier Paolo; Iodice, Delfina; Segreto, Sabrina; Storto, Giovanni; Magliulo, Mario; Palma, Giovanni Domenico De; Salvatore, Marco; Pace, Leonardo
2011-01-01
AIM: To evaluate whether FDG-positron emission tomography (PET)/computed tomography (CT) may be an accurate technique in the assessment of the T stage in patients with colorectal cancer. METHODS: Thirty four consecutive patients (20 men and 14 women; mean age: 63 years) with a histologically proven diagnosis of colorectal adenocarcinoma and scheduled for surgery in our hospital were enrolled in this study. All patients underwent FDG-PET/CT preoperatively. The primary tumor site and extent were evaluated on PET/CT images. Colorectal wall invasion was analysed according to a modified T classification that considers only three stages (≤ T2, T3, T4). Assessment of accuracy was carried out using 95% confidence intervals for T. RESULTS: Thirty five/37 (94.6%) adenocarcinomas were identified and correctly located on PET/CT images. PET/CT correctly staged the T of 33/35 lesions identified showing an accuracy of 94.3% (95% CI: 87%-100%). All T1, T3 and T4 lesions were correctly staged, while two T2 neoplasms were overstated as T3. CONCLUSION: Our data suggest that FDG-PET/CT may be an accurate modality for identifying primary tumor and defining its local extent in patients with colorectal cancer. PMID:21472100
Soyama, Takeshi; Sakuhara, Yusuke; Kudo, Kohsuke; Abo, Daisuke; Wang, Jeff; Ito, Yoichi M; Hasegawa, Yu; Shirato, Hiroki
2016-07-01
This preliminary study compared ultrasonography-computed tomography (US-CT) fusion imaging and conventional ultrasonography (US) for accuracy and time required for target identification using a combination of real phantoms and sets of digitally modified computed tomography (CT) images (digital/real hybrid phantoms). In this randomized prospective study, 27 spheres visible on B-mode US were placed at depths of 3.5, 8.5, and 13.5 cm (nine spheres each). All 27 spheres were digitally erased from the CT images, and a radiopaque sphere was digitally placed at each of the 27 locations to create 27 different sets of CT images. Twenty clinicians were instructed to identify the sphere target using US alone and fusion imaging. The accuracy of target identification of the two methods was compared using McNemar's test. The mean time required for target identification and error distances were compared using paired t tests. At all three depths, target identification was more accurate and the mean time required for target identification was significantly less with US-CT fusion imaging than with US alone, and the mean error distances were also shorter with US-CT fusion imaging. US-CT fusion imaging was superior to US alone in terms of accurate and rapid identification of target lesions.
Data fusion in X-ray computed tomography using a superiorization approach.
Schrapp, Michael J; Herman, Gabor T
2014-05-01
X-ray computed tomography (CT) is an important and widespread inspection technique in industrial non-destructive testing. However, large-sized and heavily absorbing objects cause artifacts due to either the lack of penetration of the specimen in specific directions or by having data from only a limited angular range of views. In such cases, valuable information about the specimen is not revealed by the CT measurements alone. Further imaging modalities, such as optical scanning and ultrasonic testing, are able to provide data (such as an edge map) that are complementary to the CT acquisition. In this paper, a superiorization approach (a newly developed method for constrained optimization) is used to incorporate the complementary data into the CT reconstruction; this allows precise localization of edges that are not resolvable from the CT data by itself. Superiorization, as presented in this paper, exploits the fact that the simultaneous algebraic reconstruction technique (SART), often used for CT reconstruction, is resilient to perturbations; i.e., it can be modified to produce an output that is as consistent with the CT measurements as the output of unmodified SART, but is more consistent with the complementary data. The application of this superiorized SART method to measured data of a turbine blade demonstrates a clear improvement in the quality of the reconstructed image.
Kondo, Yumi; Matsunaga, Satoru; Mochizuki, Manabu; Kadosawa, Tsuyoshi; Nakagawa, Takayuki; Nishimura, Ryohei; Sasaki, Nobuo
2008-03-01
To evaluate the efficacy of clinical staging based on computed tomography (CT) imaging over the World Health Organization (WHO) staging system based on radiography for nasal tumors in dogs, a retrospective study was conducted. This study used 112 dogs that had nasal tumors; they had undergone radiography and CT and had been histologically confirmed as having nasal tumors. Among 112 dogs, 85 (75.9%) were diagnosed as adenocarcinoma. Then they were analyzed for survival time according to each staging system. More than 70% of the patients with adenocarcinoma were classified as having WHO stage III. The patients classified under WHO stage II tended to survive longer than those classified under WHO stage III. Dogs classified under WHO stage III were further grouped into CT stages III and IV, and CT stage III patients had a significantly longer survival time than CT stage IV patients. In addition, patients treated with a combination of surgery and radiation had a significantly longer survival time than the patients who did not receive any treatment in CT stage III. On the other hand, different treatment modalities did not show a significant difference in the survival time of CT stage IV dogs. The results suggest that WHO stage III dogs may have various levels of tumor progression, indicating that the CT staging system may be more accurate than the WHO staging system.
Duan, Yuping; Bouslimi, Dalel; Yang, Guanyu; Shu, Huazhong; Coatrieux, Gouenou
2017-07-01
In this paper, we focus on the "blind" identification of the computed tomography (CT) scanner that has produced a CT image. To do so, we propose a set of noise features derived from the image chain acquisition and which can be used as CT-scanner footprint. Basically, we propose two approaches. The first one aims at identifying a CT scanner based on an original sensor pattern noise (OSPN) that is intrinsic to the X-ray detectors. The second one identifies an acquisition system based on the way this noise is modified by its three-dimensional (3-D) image reconstruction algorithm. As these reconstruction algorithms are manufacturer dependent and kept secret, our features are used as input to train a support vector machine (SVM) based classifier to discriminate acquisition systems. Experiments conducted on images issued from 15 different CT-scanner models of 4 distinct manufacturers demonstrate that our system identifies the origin of one CT image with a detection rate of at least 94% and that it achieves better performance than sensor pattern noise (SPN) based strategy proposed for general public camera devices.
Blend sign predicts poor outcome in patients with intracerebral hemorrhage.
Li, Qi; Yang, Wen-Song; Wang, Xing-Chen; Cao, Du; Zhu, Dan; Lv, Fa-Jin; Liu, Yang; Yuan, Liang; Zhang, Gang; Xiong, Xin; Li, Rui; Hu, Yun-Xin; Qin, Xin-Yue; Xie, Peng
2017-01-01
Blend sign has been recently described as a novel imaging marker that predicts hematoma expansion. The purpose of our study was to investigate the prognostic value of CT blend sign in patients with ICH. Patients with intracerebral hemorrhage who underwent baseline CT scan within 6 hours were included. The presence of blend sign on admission nonenhanced CT was independently assessed by two readers. The functional outcome was assessed by using the modified Rankin Scale (mRS) at 90 days. Blend sign was identified in 40 of 238 (16.8%) patients on admission CT scan. The proportion of patients with a poor functional outcome was significantly higher in patients with blend sign than those without blend sign (75.0% versus 47.5%, P = 0.001). The multivariate logistic regression analysis demonstrated that age, intraventricular hemorrhage, admission GCS score, baseline hematoma volume and presence of blend sign on baseline CT independently predict poor functional outcome at 90 days. The CT blend sign independently predicts poor outcome in patients with ICH (odds ratio 3.61, 95% confidence interval [1.47-8.89];p = 0.005). Early identification of blend sign is useful in prognostic stratification and may serve as a potential therapeutic target for prospective interventional studies.
A review of cognitive therapy in acute medical settings. Part I: therapy model and assessment.
Levin, Tomer T; White, Craig A; Kissane, David W
2013-04-01
Although cognitive therapy (CT) has established outpatient utility, there is no integrative framework for using CT in acute medical settings where most psychosomatic medicine (P-M) clinicians practice. Biopsychosocial complexity challenges P-M clinicians who want to use CT as the a priori psychotherapeutic modality. For example, how should clinicians modify the data gathering and formulation process to support CT in acute settings? Narrative review methodology is used to describe the framework for a CT informed interview, formulation, and assessment in acute medical settings. Because this review is aimed largely at P-M trainees and educators, exemplary dialogues model the approach (specific CT strategies for common P-M scenarios appear in the companion article.) Structured data gathering needs to be tailored by focusing on cognitive processes informed by the cognitive hypothesis. Agenda setting, Socratic questioning, and adaptations to the mental state examination are necessary. Specific attention is paid to the CT formulation, Folkman's Cognitive Coping Model, self-report measures, data-driven evaluations, and collaboration (e.g., sharing the formulation with the patient.) Integrative CT-psychopharmacological approaches and the importance of empathy are emphasized. The value of implementing psychotherapy in parallel with data gathering because of time urgency is advocated, but this is a significant departure from usual outpatient approaches in which psychotherapy follows evaluation. This conceptual approach offers a novel integrative framework for using CT in acute medical settings, but future challenges include demonstrating clinical outcomes and training P-M clinicians so as to demonstrate fidelity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, C. M., E-mail: christopher.thomas@gstt.nhs.uk; Convery, D. J.; Greener, A. G.
2014-04-15
Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was testedmore » throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.« less
NASA Astrophysics Data System (ADS)
Tsiaousis, D.; Munn, R. W.
2004-04-01
Calculations for the acetanilide crystal yield the effective polarizability (16.6 Å3), local electric field tensor, effective dipole moment (5.41 D), and dipole-dipole energy (-12.8 kJ/mol). Fourier-transform techniques are used to calculate the polarization energy P for a single charge in the perfect crystal (-1.16 eV); the charge-dipole energy WD is zero if the crystal carries no bulk dipole moment. Polarization energies for charge-transfer (CT) pairs combine with the Coulomb energy EC to give the screened Coulomb energy Escr; screening is nearly isotropic, with Escr≈EC/2.7. For CT pairs WD reduces to a term δWD arising from the interaction of the charge on each ion with the change in dipole moment on the other ion relative to the neutral molecule. The dipole moments calculated by density-functional theory methods with the B3LYP functional at the 6-311++G** level are 3.62 D for the neutral molecule, changing to 7.13 D and 4.38 D for the anion and cation, relative to the center of mass. Because of the large change in the anion, δWD reaches -0.9 eV and modifies the sequence of CT energies markedly from that of Escr, giving the lowest two CT pairs at -1.98 eV and -1.41 eV. The changes in P and WD near a vacancy are calculated; WD changes for the individual charges because the vacancy removes a dipole moment and modifies the crystal dielectric response, but δWD and EC do not change. A vacancy yields a positive change ΔP that scatters a charge or CT pair, but the change ΔWD can be negative and large enough to outweigh ΔP, yielding traps with depths that can exceed 150 meV for single charges and for CT pairs. Divacancies yield traps with depths nearly equal to the sum of those produced by the separate vacancies and so they can exceed 300 meV. These results are consistent with a mechanism of optical damage in which vacancies trap optically generated CT pairs that recombine and release energy; this can disrupt the lattice around the vacancy, thereby favoring trapping and recombination of CT pairs generated by subsequent photon absorption, leading to further lattice disruption. Revisions to previous calculations on trapping of CT pairs in anthracene are reported.
Childhood CT scans and cancer risk: impact of predisposing factors for cancer on the risk estimates.
Journy, N; Roué, T; Cardis, E; Le Pointe, H Ducou; Brisse, H; Chateil, J-F; Laurier, D; Bernier, M-O
2016-03-01
To investigate the role of cancer predisposing factors (PFs) on the associations between paediatric computed tomography (CT) scan exposures and subsequent risk of central nervous system (CNS) tumours and leukaemia. A cohort of children who underwent a CT scan in 2000-2010 in 23 French radiology departments was linked with the national childhood cancers registry and national vital status registry; information on PFs was retrieved through hospital discharge databases. In children without PF, hazard ratios of 1.07 (95% CI 0.99-1.10) for CNS tumours (15 cases) and 1.16 (95% CI 0.77-1.27) for leukaemia (12 cases) were estimated for each 10 mGy increment in CT x-rays organ doses. These estimates were similar to those obtained in the whole cohort. In children with PFs, no positive dose-risk association was observed, possibly related to earlier non-cancer mortality in this group. Our results suggest a modifying effect of PFs on CT-related cancer risks, but need to be confirmed by longer follow-up and other studies.
Pfeiffer, Tanya; Ruppert, Thomas; Schaal, Heiner; Bosch, Valerie
2013-06-20
Employing antibodies against the cytoplasmic tail of the HIV-1 glycoprotein (Env-CT), in addition to gp160/gp41, we have identified several novel small Env proteins (<25kD) in HIV-1 transfected and infected cells. Mass spectrometric and mutational analyses show that two mechanisms contribute to their generation. Thus the protein, designated Tr-Env-CT (for truncated Env-CT), consists of the C-terminal 139 amino acids (aa) of Env (aa 718-856) with the N-terminal Q718 modified to pyroglutamic acid. It is likely derived from full-length Env protein by proteolytic processing. A further heterogeneous set of slightly larger proteins, termed Env-CT* species, are rather derived from spliced mRNAs containing only those Env C-terminal residues (aa 719-856) which overlap with the second tat and rev coding exons. They are N-terminally extended in the same reading frame. It is conceivable that essential Env-CT functions may be fulfilled by these novel species rather than by the full-length glycoprotein itself. Copyright © 2013 Elsevier Inc. All rights reserved.
IMPaCT - Integration of Missions, Programs, and Core Technologies
NASA Technical Reports Server (NTRS)
Balacuit, Carlos P.; Cutts, James A.; Peterson, Craig E.; Beauchamp, Patricia M.; Jones, Susan K.; Hang, Winnie N.; Dastur, Shahin D.
2013-01-01
IMPaCT enables comprehensive information on current NASA missions, prospective future missions, and the technologies that NASA is investing in, or considering investing in, to be accessed from a common Web-based interface. It allows dependencies to be established between missions and technology, and from this, the benefits of investing in individual technologies can be determined. The software also allows various scenarios for future missions to be explored against resource constraints, and the nominal cost and schedule of each mission to be modified in an effort to fit within a prescribed budget.
CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)
NASA Astrophysics Data System (ADS)
Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.
2006-05-01
To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.
The Value of 18F-FDG PET/CT in Diagnosis and During Follow-up in 273 Patients with Chronic Q Fever.
Kouijzer, Ilse J E; Kampschreur, Linda M; Wever, Peter C; Hoekstra, Corneline; van Kasteren, Marjo E E; de Jager-Leclercq, Monique G L; Nabuurs-Franssen, Marrigje H; Wegdam-Blans, Marjolijn C A; Ammerlaan, Heidi S M; Buijs, Jacqueline; Geus-Oei, Lioe-Fee de; Oyen, Wim J G; Bleeker-Rovers, Chantal P
2018-01-01
In 1%-5% of all acute Q fever infections, chronic Q fever develops, mostly manifesting as endocarditis, infected aneurysms, or infected vascular prostheses. In this study, we investigated the diagnostic value of 18 F-FDG PET/CT in chronic Q fever at diagnosis and during follow-up. Methods: All adult Dutch patients suspected of chronic Q fever who were diagnosed since 2007 were retrospectively included until March 2015, when at least one 18 F-FDG PET/CT scan was obtained. Clinical data and results from 18 F-FDG PET/CT at diagnosis and during follow-up were collected. 18 F-FDG PET/CT scans were prospectively reevaluated by 3 nuclear medicine physicians using a structured scoring system. Results: In total, 273 patients with possible, probable, or proven chronic Q fever were included. Of all 18 F-FDG PET/CT scans performed at diagnosis, 13.5% led to a change in diagnosis. Q fever-related mortality rate in patients with and without vascular infection based on 18 F-FDG PET/CT was 23.8% and 2.1%, respectively ( P = 0.001). When 18 F-FDG PET/CT was added as a major criterion to the modified Duke criteria, 17 patients (1.9-fold increase) had definite endocarditis. At diagnosis, 19.6% of 18 F-FDG PET/CT scans led to treatment modification. During follow-up, 57.3% of 18 F-FDG PET/CT scans resulted in treatment modification. Conclusion: 18 F-FDG PET/CT is a valuable technique in diagnosis of chronic Q fever and during follow-up, often leading to a change in diagnosis or treatment modification and providing important prognostic information on patient survival. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
[Modification of the retrolabyrinthine approach with hearing preservation in CPA tumors].
Schipper, J; Lohnstein, P; Stummer, W; Knapp, F; Turowski, B; Klenzner, T
2010-02-01
In an anatomical study including a CT scan of the cadaver sections by means of a virtual model analysis the option of a modified retrolabyrinthine passage to the cerebellopontine angle (CPA) preserving the Saccus endolymphaticus and the upper petrosus sinus was analysed. Due to the individual anatomical variations of the petrosus bone the results showed several limitations with regard to the retrolabyrintine passage to the CPA. The smallest distance between the dura of the posterior fossa and the posterior semicircular canal measured in a high resolution CT was of particular importance as to how much room was available for the surgical manipulation in the retrolabyrinthine space. As the back side angle to the petrosus bone is much flatter in a translabyrinthine approach than in a retrosigmoidal approach the internal auditory canal needed to be controlled by using a 30 degree endoscope. In five patients the translabyrinthine approach was modified by temporarily preserving the labyrinth in an effort to remove the CPA tumors. Based on our clinical experience and on the findings of the anatomical and radiological studies we eventually removed the CPA tumors type B2 or C3 in three patients preserving hearing by using a modified retrolabyrinthine approach.
Gooi, J H; Pompolo, S; Karsdal, M A; Kulkarni, N H; Kalajzic, I; McAhren, S H M; Han, B; Onyia, J E; Ho, P W M; Gillespie, M T; Walsh, N C; Chia, L Y; Quinn, J M W; Martin, T J; Sims, N A
2010-06-01
The therapeutic goal of increasing bone mass by co-treatment of parathyroid hormone (PTH) and an osteoclast inhibitor has been complicated by the undefined contribution of osteoclasts to the anabolic activity of PTH. To determine whether active osteoclasts are required at the time of PTH administration, we administered a low dose of the transient osteoclast inhibitor salmon calcitonin (sCT) to young rats receiving an anabolic PTH regimen. Co-administration of sCT significantly blunted the anabolic effect of PTH as measured by peripheral quantitative computer tomography (pQCT) and histomorphometry in the femur and tibia, respectively. To determine gene targets of sCT, we carried out quantitative real time PCR and microarray analysis of metaphyseal samples 1.5, 4 and 6.5h after administration of a single injection of PTH, sCT or PTH+sCT. Known targets of PTH action, IL-6, ephrinB2 and RANKL, were not modified by co-administration with sCT. Surprisingly, at all time points, we noted a significant upregulation of sclerostin mRNA by sCT treatment, as well as down-regulation of two other osteocyte gene products, MEPE and DMP1. Immunohistochemistry confirmed that sCT administration increased the percentage of osteocytes expressing sclerostin, suggesting a mechanism by which sCT reduced the anabolic effect of PTH. Neither mRNA for CT receptor (Calcr) nor labeled CT binding could be detected in sclerostin-enriched cells differentiated from primary calvarial osteoblasts. In contrast, osteocytes freshly isolated from calvariae expressed a high level of Calcr mRNA. Furthermore immunohistochemistry revealed co-localization of CT receptor (CTR) and sclerostin in some osteocytes in calvarial sections. Taken together these data indicate that co-treatment with sCT can blunt the anabolic effect of PTH and this may involve direct stimulation of sclerostin production by osteocytes. These data directly implicate calcitonin as a negative regulator of bone formation through a previously unsuspected mechanism. Copyright 2010 Elsevier Inc. All rights reserved.
Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei
2012-10-01
To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors' classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors' automatic classification and manual segmentation were 91.6% ± 2.0%. A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution.
Computed Tomography of the Abdomen in Eight Clinically Normal Common Marmosets (Callithrix jacchus).
du Plessis, W M; Groenewald, H B; Elliott, D
2017-08-01
The aim of this study was to provide a detailed anatomical description of the abdomen in the clinically normal common marmoset by means of computed tomography (CT). Eight clinically healthy mature common marmosets ranging from 12 to 48 months and 235 to 365 g bodyweight were anesthetized and pre- and post-contrast CT examinations were performed using different CT settings in dorsal recumbency. Abdominal organs were identified and visibility noted. Diagnostic quality abdominal images could be obtained of the common marmoset despite its small size using a dual-slice CT scanner. Representative cross-sectional images were chosen from different animals illustrating the abdominal CT anatomy of clinically normal common marmosets. Identification or delineation of abdominal organs greatly improved with i.v. contrast. A modified high-frequency algorithm with edge enhancement added valuable information for identification of small structures such as the ureters. The Hounsfield unit (HU) of major abdominal organs differed from that of small animals (domestic dogs and cats). Due to their size and different anatomy, standard small animal CT protocols need to be critically assessed and adapted for exotics, such as the common marmoset. The established normal reference range of HU of major abdominal organs and adapted settings for a CT protocol will aid clinical assessment of the common marmoset. © 2017 Blackwell Verlag GmbH.
Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei
2012-01-01
Purpose: To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. Methods: The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors’ classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. Results: The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors’ automatic classification and manual segmentation were 91.6% ± 2.0%. Conclusions: A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution. PMID:23039675
Berenguer, Roberto; Pastor-Juan, María Del Rosario; Canales-Vázquez, Jesús; Castro-García, Miguel; Villas, María Victoria; Legorburo, Francisco Mansilla; Sabater, Sebastià
2018-04-24
Purpose To identify the reproducible and nonredundant radiomics features (RFs) for computed tomography (CT). Materials and Methods Two phantoms were used to test RF reproducibility by using test-retest analysis, by changing the CT acquisition parameters (hereafter, intra-CT analysis), and by comparing five different scanners with the same CT parameters (hereafter, inter-CT analysis). Reproducible RFs were selected by using the concordance correlation coefficient (as a measure of the agreement between variables) and the coefficient of variation (defined as the ratio of the standard deviation to the mean). Redundant features were grouped by using hierarchical cluster analysis. Results A total of 177 RFs including intensity, shape, and texture features were evaluated. The test-retest analysis showed that 91% (161 of 177) of the RFs were reproducible according to concordance correlation coefficient. Reproducibility of intra-CT RFs, based on coefficient of variation, ranged from 89.3% (151 of 177) to 43.1% (76 of 177) where the pitch factor and the reconstruction kernel were modified, respectively. Reproducibility of inter-CT RFs, based on coefficient of variation, also showed large material differences, from 85.3% (151 of 177; wood) to only 15.8% (28 of 177; polyurethane). Ten clusters were identified after the hierarchical cluster analysis and one RF per cluster was chosen as representative. Conclusion Many RFs were redundant and nonreproducible. If all the CT parameters are fixed except field of view, tube voltage, and milliamperage, then the information provided by the analyzed RFs can be summarized in only 10 RFs (each representing a cluster) because of redundancy. © RSNA, 2018 Online supplemental material is available for this article.
4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling.
Yang, Deshan; Lu, Wei; Low, Daniel A; Deasy, Joseph O; Hope, Andrew J; El Naqa, Issam
2008-10-01
Four-dimensional computed tomography (4D-CT) imaging technology has been developed for radiation therapy to provide tumor and organ images at the different breathing phases. In this work, a procedure is proposed for estimating and modeling the respiratory motion field from acquired 4D-CT imaging data and predicting tissue motion at the different breathing phases. The 4D-CT image data consist of series of multislice CT volume segments acquired in ciné mode. A modified optical flow deformable image registration algorithm is used to compute the image motion from the CT segments to a common full volume 3D-CT reference. This reference volume is reconstructed using the acquired 4D-CT data at the end-of-exhalation phase. The segments are optimally aligned to the reference volume according to a proposed a priori alignment procedure. The registration is applied using a multigrid approach and a feature-preserving image downsampling maxfilter to achieve better computational speed and higher registration accuracy. The registration accuracy is about 1.1 +/- 0.8 mm for the lung region according to our verification using manually selected landmarks and artificially deformed CT volumes. The estimated motion fields are fitted to two 5D (spatial 3D+tidal volume+airflow rate) motion models: forward model and inverse model. The forward model predicts tissue movements and the inverse model predicts CT density changes as a function of tidal volume and airflow rate. A leave-one-out procedure is used to validate these motion models. The estimated modeling prediction errors are about 0.3 mm for the forward model and 0.4 mm for the inverse model.
NASA Astrophysics Data System (ADS)
Zhou, Benqing; Wang, Meng; Zhou, Feifan; Song, Jun; Qu, Junle; Chen, Wei R.
2018-02-01
We report the synthesis and characterization of arginine-glycine-aspartic acid (RGD) peptide-targeted polyethylenimine (PEI)-entrapped gold nanoparticles (RGD-Au PENPs) for targeted CT imaging of hepatic carcinomas in situ. In this work, PEI sequentially modified with polyethylene glycol (PEG), and RGD linked-PEG was used as a nanoplatform to prepare AuNPs, followed by complete acetylation of PEI surface amines. We showed that the designed RGD-Au PENPs were colloidally stable and biocompatible in the given concentration range, and could be specifically taken up by αvβ3 integrin-overexpressing liver cancer cells in vitro. Furthermore, in vivo CT imaging results revealed that the particles displayed a great contrast enhancement of hepatic carcinomas region, and could target to hepatic carcinomas region in situ. With the proven biodistribution and histological examinations in vivo, the synthesized RGD-Au PENPs show a great formulation to be used as a contrast agent for targeted CT imaging of different αvβ3 integrin receptoroverexpressing tumors.
Blend sign predicts poor outcome in patients with intracerebral hemorrhage
Cao, Du; Zhu, Dan; Lv, Fa-Jin; Liu, Yang; Yuan, Liang; Zhang, Gang; Xiong, Xin; Li, Rui; Hu, Yun-Xin; Qin, Xin-Yue; Xie, Peng
2017-01-01
Introduction Blend sign has been recently described as a novel imaging marker that predicts hematoma expansion. The purpose of our study was to investigate the prognostic value of CT blend sign in patients with ICH. Objectives and methods Patients with intracerebral hemorrhage who underwent baseline CT scan within 6 hours were included. The presence of blend sign on admission nonenhanced CT was independently assessed by two readers. The functional outcome was assessed by using the modified Rankin Scale (mRS) at 90 days. Results Blend sign was identified in 40 of 238 (16.8%) patients on admission CT scan. The proportion of patients with a poor functional outcome was significantly higher in patients with blend sign than those without blend sign (75.0% versus 47.5%, P = 0.001). The multivariate logistic regression analysis demonstrated that age, intraventricular hemorrhage, admission GCS score, baseline hematoma volume and presence of blend sign on baseline CT independently predict poor functional outcome at 90 days. The CT blend sign independently predicts poor outcome in patients with ICH (odds ratio 3.61, 95% confidence interval [1.47–8.89];p = 0.005). Conclusions Early identification of blend sign is useful in prognostic stratification and may serve as a potential therapeutic target for prospective interventional studies. PMID:28829797
Zhang, Yu-Dong; Xue, Chen-Qi; Wu, Chen-Jiang; Tao, Jun; Zhou, Wan-Li; Shi, Hai-Bin
2017-01-01
To investigate whether triphasic CT with a simplified Patlak plot can be used in clinical practice for the estimate of split kidney glomerular filtration rate (SKGFR). The animal experiment included 15 rabbits that underwent 40 dynamic contrast-enhanced CT scans of the kidneys with 1.5 s time interval. Patlak-derived SKGFR was obtained using standard forty-point, two-point (unenhanced phase, arterial phase t α, and portovenous phase t β ), and a modified two-point (MTP) (unenhanced, t α , t β , and a virtual t τ [t τ = (t α + t β )/2]) image data, respectively. The MTP-Patlak plot approach was then validated in 13 patients who underwent a triphasic renal contrast-enhanced CT examination. SKGFR measured by 99 m Tc-DTPA clearance was as a standard reference. MTP-Patlak significantly reduced input function errors than two-point Patlak (21.1 ± 16.2 % vs 30.8 ± 15.2 %, p < 0.01) and showed good concordance with standard Patlak for measurement of SKGFR in animal experiment (1.20 ± 0.38 mL/g/min vs 1.51 ± 0.43 mL/g/min; linear correlation coefficient r = 0.87, p < 0.001). Human study showed that mean SKGFR was 45.7 mL/min (range, 26.5-86.2 mL/min) obtained from 99 m Tc-DTPA, and 38.2 mL/min (range, 18.6-79.3 mL/min) obtained from triphasic CT using MTP-Patlak plot. Linear correlation between the two methods was r = 0.75 (p < 0.01). The mean difference between SKGFRs as determined with the two methods was 7.4 ± 9.0 mL/min. The MTP-Patlak approach, featured with simplicity, is feasible in a clinically indicated CT examination for the evaluation of split renal function.
Lozano-Carrascal, Naroa; Delgado-Ruiz, Rafael Arcesio; Gargallo-Albiol, Jordi; Maté-Sánchez, José Eduardo; Hernandez Alfaro, Federico; Calvo-Guirado, José Luis
2016-02-01
The aim of the study was to compare the effects of porcine xenografts (MP3(®)) with or without pamindronate for the healing of small and large defects of postextraction sockets. Six beagle dogs were used in the study; second premolars and first molars of the mandible were extracted, small defects (SD) and large defects (LD) were identified. Each defect was measured and randomly filled as follows: SC (small control defects filled with MP3(®) alone), ST (small test defects filled with MP3(®) modified with pamindronate), LC (large control defects filled with MP3(®) alone), LT (large test defects filled with MP3(®) modified with pamindronate). After 4 and 8 weeks, the animals were euthanized and the percentages of new bone formation (NB), residual graft (RG) and connective tissue (CT) were analysed by histology and histomorphometry of undecalcified samples. After 4 weeks, NB formation was higher for ST compared to all groups and for LT compared to LC (P < 0.05); RG was significantly higher in both control groups compared to tests (P < 0.05); and CT was higher in large defects (LC and LT) compared to small defects. After 8 weeks, NB formation was higher for test groups (ST and LT) compared to controls (P < 0.05); RG was significantly higher in both control groups compared to tests (P < 0.05); and CT was higher in large defects (LC and LT) compared to small defects (P < 0.05). Within the limitations of this experimental study, the findings suggest that porcine xenografts modified with pamindronate favours the new bone formation and increased the porcine xenograft substitution/replacement after 4 and 8 weeks of healing. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Novoderezhkin, Vladimir I.; Dekker, Jan P.; van Grondelle, Rienk
2007-01-01
We propose an exciton model for the Photosystem II reaction center (RC) based on a quantitative simultaneous fit of the absorption, linear dichroism, circular dichroism, steady-state fluorescence, triplet-minus-singlet, and Stark spectra together with the spectra of pheophytin-modified RCs, and so-called RC5 complexes that lack one of the peripheral chlorophylls. In this model, the excited state manifold includes a primary charge-transfer (CT) state that is supposed to be strongly mixed with the pure exciton states. We generalize the exciton theory of Stark spectra by 1), taking into account the coupling to a CT state (whose static dipole cannot be treated as a small parameter in contrast to usual excited states); and 2), expressing the line shape functions in terms of the modified Redfield approach (the same as used for modeling of the linear responses). This allows a consistent modeling of the whole set of experimental data using a unified physical picture. We show that the fluorescence and Stark spectra are extremely sensitive to the assignment of the primary CT state, its energy, and coupling to the excited states. The best fit of the data is obtained supposing that the initial charge separation occurs within the special-pair PD1PD2. Additionally, the scheme with primary electron transfer from the accessory chlorophyll to pheophytin gave a reasonable quantitative fit. We show that the effectiveness of these two pathways is strongly dependent on the realization of the energetic disorder. Supposing a mixed scheme of primary charge separation with a disorder-controlled competition of the two channels, we can explain the coexistence of fast sub-ps and slow ps components of the Phe-anion formation as revealed by different ultrafast spectroscopic techniques. PMID:17526589
NASA Astrophysics Data System (ADS)
Wang, Ruizhi; Luo, Yu; Yang, Shuohui; Lin, Jiang; Gao, Dongmei; Zhao, Yan; Liu, Jinguo; Shi, Xiangyang; Wang, Xiaolin
2016-09-01
Hepatocellular carcinoma (HCC) is the most common malignant tumor of the liver. The early and effective diagnosis has always been desired. Herein, we present the preparation and characterization of hyaluronic acid (HA)-modified, multifunctional nanoparticles (NPs) targeting CD44 receptor-expressing cancer cells for computed tomography (CT)/magnetic resonance (MR) dual-mode imaging. We first modified amine-terminated generation 5 poly(amidoamine) dendrimers (G5.NH2) with an Mn chelator, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), fluorescein isothiocyanate (FI), and HA. Then, gold nanoparticles (AuNPs) were entrapped within the above raw product, denoted as G5.NH2-FI-DOTA-HA. The designed multifunctional NPs were formed after further Mn chelation and purification and were denoted as {(Au0)100G5.NH2-FI-DOTA(Mn)-HA}. These NPs were characterized via several different techniques. We found that the {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} NPs exhibited good water dispersibility, stability under different conditions, and cytocompatibility within a given concentration range. Because both AuNPs and Mn were present in the product, {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} displayed a high X-ray attenuation intensity and favorable r1 relaxivity, which are advantageous properties for targeted CT/MR dual-mode imaging. This approach was used to image HCC cells in vitro and orthotopically transplanted HCC tumors in a unique in vivo model through the CD44 receptor-mediated endocytosis pathway. This work introduces a novel strategy for preparing multifunctional NPs via dendrimer nanotechnology.
SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Y; Bowsher, J; Yan, S
2014-06-01
Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medicalmore » Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.« less
Yip, C; Thomas, C; Michaelidou, A; James, D; Lynn, R; Lei, M
2014-01-01
Objective: To investigate if cone beam CT (CBCT) can be used to estimate the delivered dose in head and neck intensity-modulated radiotherapy (IMRT). Methods: 15 patients (10 without replan and 5 with replan) were identified retrospectively. Weekly CBCT was co-registered with original planning CT. Original high-dose clinical target volume (CTV1), low-dose CTV (CTV2), brainstem, spinal cord, parotids and external body contours were copied to each CBCT and modified to account for anatomical changes. Corresponding planning target volumes (PTVs) and planning organ-at-risk volumes were created. The original plan was applied and calculated using modified per-treatment volumes on the original CT. Percentage volumetric, cumulative (planned dose delivered prior to CBCT + adaptive dose delivered after CBCT) and actual delivered (summation of weekly adaptive doses) dosimetric differences between each per-treatment and original plan were calculated. Results: There was greater volumetric change in the parotids with an average weekly difference of between −4.1% and −27.0% compared with the CTVs/PTVs (−1.8% to −5.0%). The average weekly cumulative dosimetric differences were as follows: CTV/PTV (range, −3.0% to 2.2%), ipsilateral parotid volume receiving ≥26 Gy (V26) (range, 0.5–3.2%) and contralateral V26 (range, 1.9–6.3%). In patients who required replan, the average volumetric reductions were greater: CTV1 (−2.5%), CTV2 (−6.9%), PTV1 (−4.7%), PTV2 (−11.5%), ipsilateral (−10.4%) and contralateral parotids (−12.1%), but did not result in significant dosimetric changes. Conclusion: The dosimetric changes during head and neck simultaneous integrated boost IMRT do not necessitate adaptive radiotherapy in most patients. Advances in knowledge: Our study shows that CBCT could be used for dose estimation during head and neck IMRT. PMID:24288402
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, C.-D.; Ko, S.-F.; Huang, C.-F.
We present a rare case of a central venous catheter-malposition-induced life-threatening cardiac tamponade as a result of computed tomography (CT) with contrast enhancement in an infant with a ventricular septal defect and pulmonary atresia after a modified Blalock-Taussig shunt. The diagnosis was confirmed by chest radiographs and CT study with catheter perforation through the right atrial wall and extravasation of the contrast medium into the pericardium, leading to cardiac tamponade and subsequent circulatory collapse. Two hours after successful cardiopulmonary resuscitation, the patient gradually resumed normal hemodynamic status.
Bulla, A; Casoli, C; Farace, F; Mazzarello, V; De Luca, L; Rubino, C; Montella, A
2014-01-01
The aim of the present study is to propose a new contrast agent that can be easily applied both to CT and dissection studies to replace lead oxide based formulas for comparative anatomical analyses of the vascularisation of cadaveric specimens. The infusion material was an epoxy resin, especially modified by the addition of barium sulphate to enhance its radiopacity. The final copolymer was toxicologically safe. To test the properties of the new material, several cadaveric limb injections were performed. The injected specimens were both CT scanned to perform 3D vascular reconstructions and dissected by anatomical planes. There was a perfect correspondence between the image studies and the dissections: even the smallest arteries on CT scan can be identified on the specimen and vice versa. The properties of the epoxy allowed an easy dissection of the vessels. The new imaging techniques available today, such as CT scan, can evaluate the vascular anatomy in high detail and 3D. This new contrast agent may help realising detailed vascular studies comparing CT scan results with anatomical dissections. Moreover, it may be useful for teaching surgical skills in the field of plastic surgery.
Maroules, Christopher D; Blaha, Michael J; El-Haddad, Mohamed A; Ferencik, Maros; Cury, Ricardo C
2013-01-01
Coronary CT angiography is an effective, evidence-based strategy for evaluating acute chest pain in the emergency department for patients at low-to-intermediate risk of acute coronary syndrome. Recent multicenter trials have reported that coronary CT angiography is safe, reduces time to diagnosis, facilitates discharge, and may lower overall cost compared with routine care. Herein, we provide a 10-step approach for establishing a successful coronary CT angiography program in the emergency department. The importance of strategic planning and multidisciplinary collaboration is emphasized. Patient selection and preparation guidelines for coronary CT angiography are reviewed with straightforward protocols that can be adapted and modified to clinical sites, depending on available cardiac imaging capabilities. Technical parameters and patient-specific modifications are also highlighted to maximize the likelihood of diagnostic quality examinations. Practical suggestions for quality control, process monitoring, and standardized reporting are reviewed. Finally, the role of a "triple rule-out" protocol is featured in the context of acute chest pain evaluation in the emergency department. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
DICOM structured report to track patient's radiation dose to organs from abdominal CT exam
NASA Astrophysics Data System (ADS)
Morioka, Craig; Turner, Adam; McNitt-Gray, Michael; Zankl, Maria; Meng, Frank; El-Saden, Suzie
2011-03-01
The dramatic increase of diagnostic imaging capabilities over the past decade has contributed to increased radiation exposure to patient populations. Several factors have contributed to the increase in imaging procedures: wider availability of imaging modalities, increase in technical capabilities, rise in demand by patients and clinicians, favorable reimbursement, and lack of guidelines to control utilization. The primary focus of this research is to provide in depth information about radiation doses that patients receive as a result of CT exams, with the initial investigation involving abdominal CT exams. Current dose measurement methods (i.e. CTDIvol Computed Tomography Dose Index) do not provide direct information about a patient's organ dose. We have developed a method to determine CTDIvol normalized organ doses using a set of organ specific exponential regression equations. These exponential equations along with measured CTDIvol are used to calculate organ dose estimates from abdominal CT scans for eight different patient models. For each patient, organ dose and CTDIvol were estimated for an abdominal CT scan. We then modified the DICOM Radiation Dose Structured Report (RDSR) to store the pertinent patient information on radiation dose to their abdominal organs.
Tsiaousis, D; Munn, R W
2004-04-15
Calculations for the acetanilide crystal yield the effective polarizability (16.6 A(3)), local electric field tensor, effective dipole moment (5.41 D), and dipole-dipole energy (-12.8 kJ/mol). Fourier-transform techniques are used to calculate the polarization energy P for a single charge in the perfect crystal (-1.16 eV); the charge-dipole energy W(D) is zero if the crystal carries no bulk dipole moment. Polarization energies for charge-transfer (CT) pairs combine with the Coulomb energy E(C) to give the screened Coulomb energy E(scr); screening is nearly isotropic, with E(scr) approximately E(C)/2.7. For CT pairs W(D) reduces to a term deltaW(D) arising from the interaction of the charge on each ion with the change in dipole moment on the other ion relative to the neutral molecule. The dipole moments calculated by density-functional theory methods with the B3LYP functional at the 6-311++G(**) level are 3.62 D for the neutral molecule, changing to 7.13 D and 4.38 D for the anion and cation, relative to the center of mass. Because of the large change in the anion, deltaW(D) reaches -0.9 eV and modifies the sequence of CT energies markedly from that of E(scr), giving the lowest two CT pairs at -1.98 eV and -1.41 eV. The changes in P and W(D) near a vacancy are calculated; W(D) changes for the individual charges because the vacancy removes a dipole moment and modifies the crystal dielectric response, but deltaW(D) and E(C) do not change. A vacancy yields a positive change DeltaP that scatters a charge or CT pair, but the change DeltaW(D) can be negative and large enough to outweigh DeltaP, yielding traps with depths that can exceed 150 meV for single charges and for CT pairs. Divacancies yield traps with depths nearly equal to the sum of those produced by the separate vacancies and so they can exceed 300 meV. These results are consistent with a mechanism of optical damage in which vacancies trap optically generated CT pairs that recombine and release energy; this can disrupt the lattice around the vacancy, thereby favoring trapping and recombination of CT pairs generated by subsequent photon absorption, leading to further lattice disruption. Revisions to previous calculations on trapping of CT pairs in anthracene are reported. (c) 2004 American Institute of Physics.
NASA Astrophysics Data System (ADS)
Daniel, Marie-Christine; Aras, Omer; Smith, Mark F.; Nan, Anjan; Fleiter, Thorsten
2010-04-01
The development of cardiac and pulmonary fibrosis have been associated with overexpression of angiotensin-converting enzyme (ACE). Moreover, ACE inhibitors, such as lisinopril, have shown a benificial effect for patients diagnosed with heart failure or systemic hypertension. Thus targeted imaging of the ACE is of crucial importance for monitoring of the tissue ACE activity as well as the treatment efficacy in heart failure. In this respect, lisinopril-capped gold nanoparticles were prepared to provide a new type of probe for targeted molecular imaging of ACE by tuned K-edge computed tomography (CT) imaging. Concentrated solutions of these modified gold nanoparticles, with a diameter around 16 nm, showed high contrast in CT imaging. These new targeted imaging agents were thus used for in vivo imaging on rat models.
Sekiguchi, Toshio; Shiraishi, Akira; Satake, Honoo; Kuwasako, Kenji; Takahashi, Hiroki; Sato, Masayuki; Urata, Makoto; Wada, Shuichi; Endo, Masato; Ikari, Takahiro; Hattori, Atsuhiko; Srivastav, Ajai K; Suzuki, Nobuo
2017-05-15
Calcitonin (CT) is a hormone that decreases serum calcium level by suppressing osteoclastic activity in the vertebrate bone. In vertebrates, the structure-function relationship of CTs has been studied extensively. We recently identified three CT superfamily peptides, Bf-CTFP1 to 3, and clarified the molecular and functional characteristics of their receptor and receptor activity-modifying protein in amphioxus, Branchiostoma floridae. However, the CT activity of Bf-CTFPs has yet to be investigated. In the present study, a functional analysis of Bf-CTFPs was performed using goldfish scales having both osteoclasts and osteoblasts. All Bf-CTFPs suppressed osteoclastic activity via a goldfish CT receptor. Although the primary amino acid sequences of the Bf-CTFPs showed low sequence similarity to vertebrate CTs, Bf-CTFP1 to 3 share three amino acids, Thr 25 , Thr 27 , and Pro 32 -NH 2 , that are required for receptor binding, with salmon CT. Moreover, homology model analysis revealed that the Bf-CTFPs form alpha-helical structures. The alpha-helical position and length of Bf-CTFP1 and 2 were conserved with those of a highly potent ligand, teleost CT. Interestingly, the composition of the alpha-helix of Bf-CTFP3 differed from those of teleost CT, despite that the action of Bf-CTFP3 on goldfish scales was the same as that of Bf-CTFP1 and 2. Collectively, the present study provides new insights into the structure-function relationship of CT and its functional evolution in chordates. Copyright © 2017 Elsevier Inc. All rights reserved.
Pozvek, G; Hilton, J M; Quiza, M; Houssami, S; Sexton, P M
1997-04-01
The structure/function relationship of salmon calcitonin (sCT) analogues was investigated in heterologous calcitonin receptor (CTR) expression systems. sCT analogues with progressive amino-terminal truncations intermediate of sCT-(1-32) to sCT-(8-32) were examined for their ability to act as agonists, antagonists, or inverse agonists. Two CTR cell clones, B8-H10 and G12-E12, which express approximately 5 million and 25,000 C1b receptors/cell, respectively, were used for this study. The B8-H10 clone has an approximately 80-fold increase in basal levels of intracellular cAMP due to constitutive activation of the overexpressed receptor. In whole-cell competition binding studies, sCT-(1-32) was more potent than any of its amino-terminally truncated analogues in competition for 125I-sCT binding. In cAMP accumulation studies, sCT-(1-32) and modified analogues sCT-(2-32) and sCT-(3-32) had agonist activities. SDZ-216-710, with an amino-terminal truncation of four amino acids, behaved as a partial agonist/antagonist, whereas amino-terminal truncations of six or seven amino acid residues produced a 16-fold reduction in basal cAMP levels and attenuated the response to the agonist sCT-(1-32) in the constitutively active CTR system. This inverse agonist effect was insensitive to pertussis toxin inhibition. In contrast, the inverse agonist activity of these peptides was not observed in the nonconstitutively active CTR system, in which sCT analogues with amino-terminal truncations of four or more amino acids behaved as neutral competitive antagonists. These results suggest that the inverse agonist activity is mediated by stabilization of the inactive state of the receptor, which does not couple to G protein, and attenuates basal signaling initiated by ligand-independent activation of the effector adenylyl cyclase.
Esquivel-Pérez, Rita; Moreno-Fierros, Leticia
2005-01-01
Evidence from several sources support the assertion that cholera toxin (CT) is a potent immunogen and mucosal adjuvant; however there are also reports showing its lack of adjuvanticity against some antigens. Cry1Ac protoxin also exerts adjuvant effects in the antibody responses to proteins and polysaccharides but its adjuvanticity with regard to peptide vaccines had not been tested. To probe whether the adjuvant effects of these proteins varied depending on the antigen co-administered, we evaluated antipeptide antibody responses in serum and mucosal samples (vaginal, intestinal, and pulmonary) of mice that were immunized by intranasal or intraperitoneal routes with one of two distinct hybrid C4/V3 HIV peptides, either alone or with CT or Cry1Ac. The tested HIV 1 peptides differed in two aminoacids, T1SP10MN(A) was modified at the SP10 region by the substitution of the isoleucines 12 and 14 for cysteines and was called modified (m)T1SP10MN(A). Our data indicate that the adjuvant effects of CT and Cry1Ac are different. In addition they vary depending on the antigen co-administered and the number of antigen doses, because after three doses moderate adjuvant effects of CT and Cry1Ac on anti-peptide serum and mucosal antibody responses were observed only against the mT1SP10MN(A). In contrast, to attain significant adjuvant effects against the T1SP10MN, four doses were required. Interestingly we found that modification of the HIV peptide increases its immunogenicity without altering the principal neutralizing determinant (SP10).
Design and Development of a Megavoltage CT Scanner for Radiation Therapy.
NASA Astrophysics Data System (ADS)
Chen, Ching-Tai
A Varian 4 MeV isocentric therapy accelerator has been modified to perform also as a CT scanner. The goal is to provide low cost computed tomography capability for use in radiotherapy. The system will have three principal uses. These are (i) to provide 2- and 3-dimensional maps of electron density distribution for CT assisted therapy planning, (ii) to aid in patient set up by providing sectional views of the treatment volume and high contrast scout-mode verification images and (iii) to provide a means for periodically checking the patients anatomical conformation against what was used to generate the original therapy plan. The treatment machine was modified by mounting an array of detectors on a frame bolted to the counter weight end of the gantry in such a manner as to define a 'third generation' CT Scanner geometry. The data gathering is controlled by a Z-80 based microcomputer system which transfers the x-ray transmission data to a general purpose PDP 11/34 for processing. There a series of calibration processes and a logarithmic conversion are performed to get projection data. After reordering the projection data to an equivalent parallel beam sinogram format a convolution algorithm is employed to construct the image from the equivalent parallel projection data. Results of phantom studies have shown a spatial resolution of 2.6 mm and an electron density discrimination of less than 1% which are sufficiently good for accurate therapy planning. Results also show that the system is linear to within the precision of our measurement ((DBLTURN).75%) over a wide range of electron densities corresponding to those found in body tissues. Animal and human images are also presented to demonstrate that the system's imaging capability is sufficient to allow the necessary visualization of anatomy.
Peng, Chen; Zheng, Linfeng; Chen, Qian; Shen, Mingwu; Guo, Rui; Wang, Han; Cao, Xueyan; Zhang, Guixiang; Shi, Xiangyang
2012-02-01
We report the synthesis and characterization of dendrimer-entrapped gold nanoparticles (Au DENPs) modified by polyethylene glycol (PEG) with enhanced biocompatibility for computed tomography (CT) imaging applications. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH(2)) modified by PEG monomethyl ether (G5.NH(2)-mPEG(20)) were used as templates to synthesize Au DENPs, followed by acetylation of the remaining dendrimer terminal amines to generate PEGylated Au DENPs. The partial PEGylation modification of dendrimer terminal amines allows high loading of Au within the dendrimer interior, and consequently by simply varying the Au salt/dendrimer molar ratio, the size of the PEGylated Au DENPs can be controlled at a range of 2-4 nm with a narrow size distribution. The formed PEGylated Au DENPs are water-dispersible, stable in a pH range of 5-8 and a temperature range of 0-50 °C, and non-cytotoxic at a concentration as high as 100 μm. X-ray absorption coefficient measurements show that the attenuation intensity of the PEGylated Au DENPs is much higher than that of Omnipaque with iodine concentration similar to Au. With the sufficiently long half-decay time demonstrated by pharmacokinetics studies, the PEGylated Au DENPs enabled not only X-ray CT blood pool imaging of mice and rats after intravenous injection of the particles, but also effective CT imaging of a xenograft tumor model in nude mice. These findings suggest that the designed PEGylated Au DENPs can be used as a promising contrast agent with enhanced biocompatibility for CT imaging of various biological systems, especially in cancer diagnosis. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Thompson, John D.; Chakraborty, Dev P.; Szczepura, Katy; Vamvakas, Ioannis; Tootell, Andrew; Manning, David J.; Hogg, Peter
2015-03-01
Purpose: To investigate the dose saving potential of iterative reconstruction (IR) in a computed tomography (CT) examination of the thorax. Materials and Methods: An anthropomorphic chest phantom containing various configurations of simulated lesions (5, 8, 10 and 12mm; +100, -630 and -800 Hounsfield Units, HU) was imaged on a modern CT system over a tube current range (20, 40, 60 and 80mA). Images were reconstructed with (IR) and filtered back projection (FBP). An ATOM 701D (CIRS, Norfolk, VA) dosimetry phantom was used to measure organ dose. Effective dose was calculated. Eleven observers (15.11+/-8.75 years of experience) completed a free response study, localizing lesions in 544 single CT image slices. A modified jackknife alternative free-response receiver operating characteristic (JAFROC) analysis was completed to look for a significant effect of two factors: reconstruction method and tube current. Alpha was set at 0.05 to control the Type I error in this study. Results: For modified JAFROC analysis of reconstruction method there was no statistically significant difference in lesion detection performance between FBP and IR when figures-of-merit were averaged over tube current (F(1,10)=0.08, p = 0.789). For tube current analysis, significant differences were revealed between multiple pairs of tube current settings (F(3,10) = 16.96, p<0.001) when averaged over image reconstruction method. Conclusion: The free-response study suggests that lesion detection can be optimized at 40mA in this phantom model, a measured effective dose of 0.97mSv. In high-contrast regions the diagnostic value of IR, compared to FBP, is less clear.
Sağlam, Özlem; Kızılkaya, Bayram; Uysal, Hüseyin; Dilgin, Yusuf
2016-01-15
A novel amperometric glucose biosensor was proposed in flow injection analysis (FIA) system using glucose oxidase (GOD) and Quantum dot (ZnS-CdS) modified Pencil Graphite Electrode (PGE). After ZnS-CdS film was electrochemically deposited onto PGE surface, GOD was immobilized on the surface of ZnS-CdS/PGE through crosslinking with chitosan (CT). A pair of well-defined reversible redox peak of GOD was observed at GOD/CT/ZnS-CdS/PGE based on enzyme electrode by direct electron transfer between the protein and electrode. Further, obtained GOD/CT/ZnS-CdS/PGE offers a disposable, low cost, selective and sensitive electrochemical biosensing of glucose in FIA system based on the decrease of the electrocatalytic response of the reduced form of GOD to dissolved oxygen. Under optimum conditions (flow rate, 1.3mL min(-1); transmission tubing length, 10cm; injection volume, 100μL; and constant applied potential, -500mV vs. Ag/AgCl), the proposed method displayed a linear response to glucose in the range of 0.01-1.0mM with detection limit of 3.0µM. The results obtained from this study would provide the basis for further development of the biosensing using PGE based FIA systems. Copyright © 2015 Elsevier B.V. All rights reserved.
Lopa, Nasrin Siraj; Rahman, Md Mahbubur; Jang, Hohyoun; Sutradhar, Sabuj Chandra; Ahmed, Faiz; Ryu, Taewook; Kim, Whangi
2017-12-06
2,4-Dinitrophenylhydrazine (DNPH) was electropolymerized on the surface of an anodized glassy carbon electrode by cyclic voltammetry. The anodized electrode has a highly electroactive surface due to the creation of chemically functionalized graphitic nanoparticles, and this facilitates the formation of poly-DNPH via radical polymerization. Poly-DNPH displays excellent redox activity due to the presence of nitro groups on its backbone. These catalyze the electro-oxidation of hydroquinone (HQ) and catechol (CT). The peak-to-peak separation is around 109 mV, while a bare GCE cannot resolve the peaks (located at 165 and 274 mV vs. Ag/AgCl). Sensitivity is also enhanced to ∼1.20 and 1.19 μA·cm -2 ·μM -1 , respectively. The sensor has a linear response that covers the 20-250 μM concentration range for both HQ and CT, with 0.75 and 0.76 μM detection limits, respectively, at simultaneous detection. Commonly present species do not interfere. Graphical abstract A novel conducting poly(2,4-dinitrophenylhydrazine)-modified anodized glassy carbon electrode (pDNPH/AGCE) was developed by electrochemical method. The electro-catalytic activity of pDNPH/AGCE sensor was investigated for the selective and simultaneous electrochemical detection of hydroquinone (HQ) and catechol (CT), which revealed high sensitivities and low detection limits with excellent stability.
He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating
2010-07-01
This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Kim, Sangroh; Yoshizumi, Terry T; Yin, Fang-Fang; Chetty, Indrin J
2013-04-21
Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan-scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the 'ISource = 8: Phase-Space Source Incident from Multiple Directions' in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the spiral CT scan dose in the BEAMnrc/EGSnrc system.
NASA Astrophysics Data System (ADS)
Kim, Sangroh; Yoshizumi, Terry T.; Yin, Fang-Fang; Chetty, Indrin J.
2013-04-01
Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan—scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the ‘ISource = 8: Phase-Space Source Incident from Multiple Directions’ in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the spiral CT scan dose in the BEAMnrc/EGSnrc system.
Nettleton, Jennifer A.; Steffen, Lyn M.; Ballantyne, Christie M.; Boerwinkle, Eric; Folsom, Aaron R.
2008-01-01
Polymorphisms in genes involved in HDL-cholesterol (HDL-C) metabolism influence plasma HDL-C concentrations. We examined whether dietary fat intake modified relations between HDL-C and polymorphisms in hepatic lipase (LIPC-514C→T), cholesteryl ester transfer protein (CETP TaqIB), and lipoprotein lipase (LPL S447X) genes. Diet (food frequency questionnaire), plasma lipids, and LIPC, CETP, and LPL genotypes were assessed in ~12,000 White and African American adults. In both races and all genotypes studied, minor allele homozygotes had highest HDL-C concentrations compared to the other genotypes (P <0.001). However, main effects were modified by usual dietary fat intake. In African Americans— women somewhat more strongly than men— LIPC TT homozygotes with fat intake ≥33.2% of energy had ~3-4 mg/dL higher HDL-C concentrations than CC and CT genotypes. In contrast, when fat intake was <33.2% of energy, TT homozygotes had HDL-C concentrations ~3.5 mg/dL greater than those with the CC genotype but not different from those with the CT genotype (Pinteraction =0.013). In Whites, LPL GG homozygotes had greatest HDL-C at lower total, saturated, and monounsaturated fat intakes but lowest HDL-C at higher intakes of these fats (Pinteraction ≤0.002). Dietary fat did not modify associations between CETP and HDL-C. In conclusion, these data show that plasma HDL-C differs according to LIPC, LPL, and CETP genotypes. In the case of LIPC and LPL, data suggest dietary fat modifies these relations. PMID:17157861
Hyperspectral optical tomography of intrinsic signals in the rat cortex
Konecky, Soren D.; Wilson, Robert H.; Hagen, Nathan; Mazhar, Amaan; Tkaczyk, Tomasz S.; Frostig, Ron D.; Tromberg, Bruce J.
2015-01-01
Abstract. We introduce a tomographic approach for three-dimensional imaging of evoked hemodynamic activity, using broadband illumination and diffuse optical tomography (DOT) image reconstruction. Changes in diffuse reflectance in the rat somatosensory cortex due to stimulation of a single whisker were imaged at a frame rate of 5 Hz using a hyperspectral image mapping spectrometer. In each frame, images in 38 wavelength bands from 484 to 652 nm were acquired simultaneously. For data analysis, we developed a hyperspectral DOT algorithm that used the Rytov approximation to quantify changes in tissue concentration of oxyhemoglobin (ctHbO2) and deoxyhemoglobin (ctHb) in three dimensions. Using this algorithm, the maximum changes in ctHbO2 and ctHb were found to occur at 0.29±0.02 and 0.66±0.04 mm beneath the surface of the cortex, respectively. Rytov tomographic reconstructions revealed maximal spatially localized increases and decreases in ctHbO2 and ctHb of 321±53 and 555±96 nM, respectively, with these maximum changes occurring at 4±0.2 s poststimulus. The localized optical signals from the Rytov approximation were greater than those from modified Beer–Lambert, likely due in part to the inability of planar reflectance to account for partial volume effects. PMID:26835483
Dillman, Jonathan R; Smith, Ethan A; Sanchez, Ramon; DiPietro, Michael A; Dehkordy, Soudabeh Fazeli; Adler, Jeremy; DeMatos-Maillard, Vera; Khalatbari, Shokoufeh; Davenport, Matthew S
2016-04-01
There is a paucity of published literature describing ultrasound (US)-US and US-MR enterography (MRE) inter-radiologist agreement in pediatric small bowel Crohn disease. To prospectively assess US-US and US-MRE inter-radiologist agreement in pediatric small bowel Crohn disease. Institutional Review Board approval and informed consent/assent were obtained for this HIPAA-compliant prospective cohort study of children with newly diagnosed distal small bowel Crohn disease (July 2012 to December 2014). Enrolled subjects (n = 29) underwent two small bowel US examinations performed by blinded independent radiologists both before and at multiple time points after initiation of medical therapy (231 unique US examinations, in total); 134 US examinations were associated with concurrent MRE. The MRE examination was interpreted by a third blinded radiologist. The following was documented on each examination: involved length of ileum (cm); maximum bowel wall thickness (mm); amount of bowel wall and mesenteric Doppler signal, and presence of stricture, penetrating disease and/or abscess. Inter-radiologist agreement was assessed with single-measure, three-way, mixed-model intra-class correlation coefficients (ICC) and prevalence-adjusted, bias-adjusted kappa statistics (κ). Numbers in brackets are 95% confidence intervals. Ultrasound-US agreement was moderate for involved length (ICC: 0.41 [0.35-0.49]); substantial for maximum bowel wall thickness (ICC: 0.67 [0.64-0.70]); moderate for bowel wall Doppler signal (ICC: 0.53 [0.48-0.59]); slight for mesenteric Doppler signal (ICC: 0.25 [0.18-0.42]), and moderate to almost perfect for stricture (κ: 0.54), penetrating disease (κ: 0.80), and abscess (κ: 0.96). US-MRE agreement was moderate for involved length (ICC: 0.42 [0.37-0.49]); substantial for maximum bowel wall thickness (ICC: 0.66 [0.65-0.69]), and substantial to almost perfect for stricture (κ: 0.61), penetrating disease (κ: 0.72) and abscess (κ: 0.88). Ultrasound-US agreement was similar to US-MRE agreement for assessing pediatric small bowel Crohn disease. Discrepancies in US-US and US-MRE reporting question the utility of US as an accurate, reproducible radiologic biomarker for assessing response to medical therapy and disease-related complications.
Integration of a Miniaturized Conductivity Sensor into an Animal-Borne Instrument
2013-09-30
inductive sensors. However, there is a trade -off between size and accuracy. Decreasing size resuls in a decreased accuracy. In addition, by...modified for easy integration into the existing SRDL. The CT package will then be intergrated into the SRDL tested in the lab. After the successful
18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.
Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S
2017-02-01
This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.
Indicators for technological, environmental and economic sustainability of ozone contactors.
Zhang, Jie; Tejada-Martinez, Andres E; Lei, Hongxia; Zhang, Qiong
2016-09-15
Various studies have attempted to improve disinfection efficiency as a way to improve the sustainability of ozone disinfection which is a critical unit process for water treatment. Baffling factor, CT10, and log-inactivation are commonly used indicators for quantifying disinfection credits. However the applicability of these indicators and the relationship between these indicators have not been investigated in depth. This study simulated flow, tracer transport, and chemical species transport in a full-scale ozone contactor operated by the City of Tampa Water Department and six other modified designs using computational fluid dynamics (CFD). Through analysis of the simulation results, we found that baffling factor and CT10 are not optimal indicators of disinfection performance. We also found that the relationship between effluent CT obtained from CT transport simulation and baffling factor depends on the location of ozone release. In addition, we analyzed the environmental and economic impacts of ozone contactor designs and upgrades and developed a composite indicator to quantify the sustainability in technological, environmental and economic dimensions. Copyright © 2016 Elsevier Ltd. All rights reserved.
SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY.
Feng, Qianjin; Foskey, Mark; Tang, Songyuan; Chen, Wufan; Shen, Dinggang
2009-08-07
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First, a modified scale invariant feature transform (SIFT) local descriptor, which is more distinctive than general intensity and gradient features, is used to characterize the image features. Second, an online training approach is used to build the shape statistics for accurately capturing intra-patient variation, which is more important than inter-patient variation for prostate segmentation in clinical radiotherapy. Experimental results show that the proposed method is robust and accurate, suitable for clinical application.
SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY
Feng, Qianjin; Foskey, Mark; Tang, Songyuan; Chen, Wufan; Shen, Dinggang
2010-01-01
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First, a modified scale invariant feature transform (SIFT) local descriptor, which is more distinctive than general intensity and gradient features, is used to characterize the image features. Second, an online training approach is used to build the shape statistics for accurately capturing intra-patient variation, which is more important than inter-patient variation for prostate segmentation in clinical radiotherapy. Experimental results show that the proposed method is robust and accurate, suitable for clinical application. PMID:21197416
Wang, Xiuyun; Huang, Wanlu; Yang, Zhimin; Liu, Jun; Huang, Bingru
2016-01-01
Heat stress transcription factor A2s (HsfA2s) are key regulators in plant response to high temperature. Our objectives were to isolate an HsfA2 gene (CtHsfA2b) from a warm-season grass species, African bermudagrass (Cynodon transvaalensis Burtt-Davy), and to determine the physiological functions and transcriptional regulation of HsfA2 for improving heat tolerance. Gene expression analysis revealed that CtHsfA2b was heat-inducible and exhibited rapid response to increasing temperature. Ectopic expression of CtHsfA2b improved heat tolerance in Arabidopsis and restored heat-sensitive defects of Arabidopsis hsfa2 mutant, which was demonstrated by higher survival rate and photosynthetic parameters, and lower electrolyte leakage in transgenic plants compared to the WT or hsfa2 mutant. CtHsfA2b transgenic plants showed elevated transcriptional regulation of several downstream genes, including those encoding ascorbate peroxidase (AtApx2) and heat shock proteins [AtHsp18.1-CI, AtHsp22.0-ER, AtHsp25.3-P and AtHsp26.5-P(r), AtHsp70b and AtHsp101-3]. CtHsfA2b was found to bind to the heat shock element (HSE) on the promoter of AtApx2 and enhanced transcriptional activity of AtApx2. These results suggested that CtHsfA2b could play positive roles in heat protection by up-regulating antioxidant defense and chaperoning mechanisms. CtHsfA2b has the potential to be used as a candidate gene to genetically modify cool-season species for improving heat tolerance. PMID:27320381
Lymph node detection in IASLC-defined zones on PET/CT images
NASA Astrophysics Data System (ADS)
Song, Yihua; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.
2016-03-01
Lymph node detection is challenging due to the low contrast between lymph nodes as well as surrounding soft tissues and the variation in nodal size and shape. In this paper, we propose several novel ideas which are combined into a system to operate on positron emission tomography/ computed tomography (PET/CT) images to detect abnormal thoracic nodes. First, our previous Automatic Anatomy Recognition (AAR) approach is modified where lymph node zones predominantly following International Association for the Study of Lung Cancer (IASLC) specifications are modeled as objects arranged in a hierarchy along with key anatomic anchor objects. This fuzzy anatomy model built from diagnostic CT images is then deployed on PET/CT images for automatically recognizing the zones. A novel globular filter (g-filter) to detect blob-like objects over a specified range of sizes is designed to detect the most likely locations and sizes of diseased nodes. Abnormal nodes within each automatically localized zone are subsequently detected via combined use of different items of information at various scales: lymph node zone model poses found at recognition indicating the geographic layout at the global level of node clusters, g-filter response which hones in on and carefully selects node-like globular objects at the node level, and CT and PET gray value but within only the most plausible nodal regions for node presence at the voxel level. The models are built from 25 diagnostic CT scans and refined for an object hierarchy based on a separate set of 20 diagnostic CT scans. Node detection is tested on an additional set of 20 PET/CT scans. Our preliminary results indicate node detection sensitivity and specificity at around 90% and 85%, respectively.
Demirezen, Nihat; Tarınç, Derya; Polat, Duygu; Ceşme, Mustafa; Gölcü, Ayşegül; Tümer, Mehmet
2012-08-01
Complexes of trimethoprim (TMP), with Cu(II), Zn(II), Pt(II), Ru(III) and Fe(III) have been synthesized. Then, these complexes have been characterized by spectroscopic techniques involving UV-vis, IR, mass and (1)H NMR. CHN elemental analysis, electrochemical and thermal behavior of complexes have also been investigated. The electrochemical properties of all complexes have been investigated by cyclic voltammetry (CV) using glassy carbon electrode. The biological activity of the complexes has been evaluated by examining their ability to bind to calf-thymus DNA (CT DNA) with UV spectroscopy and cyclic voltammetry. UV studies of the interaction of the complexes with DNA have shown that these compounds can bind to CT DNA. The binding constants of the complexes with CT DNA have also been calculated. The cyclic voltammograms of the complexes in the presence of CT DNA have shown that the complexes can bind to CT DNA by both the intercalative and the electrostatic binding mode. The antimicrobial activity of these complexes has been evaluated against three Gram-positive and four Gram-negative bacteria. Antifungal activity against two different fungi has been evaluated and compared with the reference drug TMP. Almost all types of complexes show excellent activity against all type of bacteria and fungi. The morphology of the CT DNA, TMP, metal ions and metal complexes has been investigated by scanning electron microscopy (SEM). To get the SEM images, the interaction of compounds with CT DNA has been studied by means of differential pulse voltammetry (DPV) at CT DNA modified pencil graphite electrode (PGE). The decrease in intensity of the guanine oxidation signals has been used as an indicator for the interaction mechanism. Copyright © 2012 Elsevier B.V. All rights reserved.
Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C
The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.
Abuhaimed, Abdullah; Martin, Colin J; Sankaralingam, Marimuthu; Gentle, David J
2015-07-21
A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to the ratio of the cumulative dose at the middle of a CT scan to the volume weighted CTDI (CTDIvol), and was investigated for conventional multi-slice CT scanners operating with a moving table. As the stationary table mode, which is the basis for cone beam CT (CBCT) scans, differs from that used for conventional CT scans, the aim of this study was to investigate the extension of the Gx(L) function to CBCT scans. An On-Board Imager (OBI) system integrated with a TrueBeam linac was simulated with Monte Carlo EGSnrc/BEAMnrc, and the absorbed dose was calculated within PMMA, polyethylene (PE), and water head and body phantoms using EGSnrc/DOSXYZnrc, where the body PE body phantom emulated the ICRU/AAPM phantom. Beams of width 40-500 mm and beam qualities at tube potentials of 80-140 kV were studied. Application of a modified function of beam width (W) termed Gx(W), for which the cumulative dose for CBCT scans f (0) is normalized to the weighted CTDI (CTDIw) for a reference beam of width 40 mm, was investigated as a possible option. However, differences were found in Gx(W) with tube potential, especially for body phantoms, and these were considered to be due to differences in geometry between wide beams used for CBCT scans and those for conventional CT. Therefore, a modified function Gx(W)100 has been proposed, taking the form of values of f (0) at each position in a long phantom, normalized with respect to dose indices f 100(150)x measured with a 100 mm pencil ionization chamber within standard 150 mm PMMA phantoms, using the same scanning parameters, beam widths and positions within the phantom. f 100(150)x averages the dose resulting from a CBCT scan over the 100 mm length. Like the Gx(L) function, the Gx(W)100 function showed only a weak dependency on tube potential at most positions for the phantoms studied. The results were fitted to polynomial equations from which f (0) within the longer PMMA, PE, or water phantoms can be evaluated from measurements of f 100(150)x. Comparisons with other studies, suggest that these functions may be suitable for application to any CT or CBCT scan acquired with stationary table mode.
Predicting stroke outcome using DCE-CT measured blood velocity
NASA Astrophysics Data System (ADS)
Oosterbroek, Jaap; Bennink, Edwin; Dankbaar, Jan Willem; Horsch, Alexander D.; Viergever, Max A.; Velthuis, Birgitta K.; de Jong, Hugo W. A. M.
2015-03-01
CT plays an important role in the diagnosis of acute stroke patients. Dynamic contrast enhanced CT (DCE-CT) can estimate local tissue perfusion and extent of ischemia. However, hemodynamic information of the large intracranial vessels may also be obtained from DCE-CT data and may contain valuable diagnostic information. We describe a novel method to estimate intravascular blood velocity (IBV) in large cerebral vessels using DCE-CT data, which may be useful to help predict stroke outcome. DCE-CT scans from 34 patients with isolated M1 occlusions were included from a large prospective multi-center cohort study of patients with acute ischemic stroke. Gaussians fitted to the intravascular data yielded the time-to-peak (TTP) and cerebral-blood-volume (CBV). IBV was computed by taking the inverse of the TTP gradient magnitude. Voxels with a CBV of at least 10% of the CBV found in the arterial input function were considered part of a vessel. Mid-sagittal planes were drawn manually and averages of the IBV over all vessel-voxels (arterial and venous) were computed for each hemisphere. Mean-hemisphere IBV differences, mean-hemisphere TTP differences, and hemisphere vessel volume differences were used to differentiate between patients with good and bad outcome (modified Rankin Scale score <3 versus ≥3 at 90 days) using ROC analysis. AUCs from the ROC for IBV, TTP, and vessel volume were 0.80, 0.67 and 0.62 respectively. In conclusion, IBV was found to be a better predictor of patient outcome than the parameters used to compute it and may be a promising new parameter for stroke outcome prediction.
Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu
2009-06-01
With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.
Charge-transfer modified embedded atom method dynamic charge potential for Li-Co-O system
NASA Astrophysics Data System (ADS)
Kong, Fantai; Longo, Roberto C.; Liang, Chaoping; Nie, Yifan; Zheng, Yongping; Zhang, Chenxi; Cho, Kyeongjae
2017-11-01
To overcome the limitation of conventional fixed charge potential methods for the study of Li-ion battery cathode materials, a dynamic charge potential method, charge-transfer modified embedded atom method (CT-MEAM), has been developed and applied to the Li-Co-O ternary system. The accuracy of the potential has been tested and validated by reproducing a variety of structural and electrochemical properties of LiCoO2. A detailed analysis on the local charge distribution confirmed the capability of this potential for dynamic charge modeling. The transferability of the potential is also demonstrated by its reliability in describing Li-rich Li2CoO2 and Li-deficient LiCo2O4 compounds, including their phase stability, equilibrium volume, charge states and cathode voltages. These results demonstrate that the CT-MEAM dynamic charge potential could help to overcome the challenge of modeling complex ternary transition metal oxides. This work can promote molecular dynamics studies of Li ion cathode materials and other important transition metal oxides systems that involve complex electrochemical and catalytic reactions.
Charge-transfer modified embedded atom method dynamic charge potential for Li-Co-O system.
Kong, Fantai; Longo, Roberto C; Liang, Chaoping; Nie, Yifan; Zheng, Yongping; Zhang, Chenxi; Cho, Kyeongjae
2017-11-29
To overcome the limitation of conventional fixed charge potential methods for the study of Li-ion battery cathode materials, a dynamic charge potential method, charge-transfer modified embedded atom method (CT-MEAM), has been developed and applied to the Li-Co-O ternary system. The accuracy of the potential has been tested and validated by reproducing a variety of structural and electrochemical properties of LiCoO 2 . A detailed analysis on the local charge distribution confirmed the capability of this potential for dynamic charge modeling. The transferability of the potential is also demonstrated by its reliability in describing Li-rich Li 2 CoO 2 and Li-deficient LiCo 2 O 4 compounds, including their phase stability, equilibrium volume, charge states and cathode voltages. These results demonstrate that the CT-MEAM dynamic charge potential could help to overcome the challenge of modeling complex ternary transition metal oxides. This work can promote molecular dynamics studies of Li ion cathode materials and other important transition metal oxides systems that involve complex electrochemical and catalytic reactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chen, J
Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due tomore » the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.« less
Micro-CT images reconstruction and 3D visualization for small animal studying
NASA Astrophysics Data System (ADS)
Gong, Hui; Liu, Qian; Zhong, Aijun; Ju, Shan; Fang, Quan; Fang, Zheng
2005-01-01
A small-animal x-ray micro computed tomography (micro-CT) system has been constructed to screen laboratory small animals and organs. The micro-CT system consists of dual fiber-optic taper-coupled CCD detectors with a field-of-view of 25x50 mm2, a microfocus x-ray source, a rotational subject holder. For accurate localization of rotation center, coincidence between the axis of rotation and centre of image was studied by calibration with a polymethylmethacrylate cylinder. Feldkamp"s filtered back-projection cone-beam algorithm is adopted for three-dimensional reconstruction on account of the effective corn-beam angle is 5.67° of the micro-CT system. 200x1024x1024 matrix data of micro-CT is obtained with the magnification of 1.77 and pixel size of 31x31μm2. In our reconstruction software, output image size of micro-CT slices data, magnification factor and rotation sample degree can be modified in the condition of different computational efficiency and reconstruction region. The reconstructed image matrix data is processed and visualization by Visualization Toolkit (VTK). Data parallelism of VTK is performed in surface rendering of reconstructed data in order to improve computing speed. Computing time of processing a 512x512x512 matrix datasets is about 1/20 compared with serial program when 30 CPU is used. The voxel size is 54x54x108 μm3. The reconstruction and 3-D visualization images of laboratory rat ear are presented.
Frohnmeyer, Esther; Frisch, Farina; Falke, Sven; Betzel, Christian; Fischer, Markus
2018-03-10
Aptamers are single-stranded DNA or RNA oligonucleotides, which have been emerging as recognition elements in disease diagnostics and food control, including the detection of bacterial toxins. In this study, we employed the semi-automated just in time-selection to identify aptamers that bind to cholera toxin (CT) with high affinity and specificity. CT is the main virulence factor of Vibrio cholerae and the causative agent of the eponymous disease. For the selected aptamers, dissociation constants in the low nanomolar range (23-56 nM) were determined by fluorescence-based affinity chromatography and cross-reactivity against related proteins was evaluated by direct enzyme-linked aptamer assay (ELAA). Aptamer CT916 has a dissociation constant of 48.5 ± 0.5 nM and shows negligible binding to Shiga-like toxin 1B, protein A and BSA. This aptamer was chosen to develop a sandwich ELAA for the detection of CT from binding buffer and local tap water. Amine-C6- or biotin-modified CT916 was coupled to magnetic beads to serve as the capture element. Using an anti-CT polyclonal antibody as the reporter, detection limits of 2.1 ng/ml in buffer and 2.4 ng/ml in tap water, with a wide log-linear dynamic range from 1 ng/ml to 1000 ng/ml and 500 ng/ml, respectively, were achieved. Copyright © 2018 Elsevier B.V. All rights reserved.
Chromium chains as polydentate fluoride ligands for actinides and group IV metals.
Leng, Ji-Dong; Kostopoulos, Andreas K; Isherwood, Liam H; Ariciu, Ana-Maria; Tuna, Floriana; Vitórica-Yrezábal, Iñigo J; Pritchard, Robin G; Whitehead, George F S; Timco, Grigore A; Mills, David P; Winpenny, Richard E P
2018-05-08
The reactions of {Cr6} horseshoe chains {[nPr2NH2]3[Cr6F11(O2CtBu)10]}2, 1 and precursors of actinides and group IV metals led to a series of ring complexes [nPr2NH2][Cr7TiF6O2(O2CtBu)16], 2, [nPr2NH2][Cr6Ti2F5O3(O2CtBu)16], 3, [Cr6ThF7(O2CtBu)15 (Me2SO)], 4, [(nPr2NH2)2(Cr6Th2F12(O2CtBu)16)], 5 and [nPr2NH2][Cr6U2O2F8(O2CtBu)16(Me2SO)], 6. X-ray structure studies indicate that the {Cr6} chains maintain their structures in these complexes, acting as polydentate fluoride ligands. Their static magnetic properties were measured and fitted by isotropic exchange Hamiltonian. In accordance with 1, the magnetic exchanges between CrIII are antiferromagnetic, while the exchange interactions can be modified by the tetravalent metals. For compound 6, ferromagnetic exchanges JCr-U and JU-U are obtained. EPR spectra of compounds 2-5 were measured at Q band and were simulated. The spectrum of 2 has the same profile as {Cr7Cd} and {Cr7Zn} rings with a ground state S = 3/2. 3, 4 and 5 give similar EPR spectra with S = 0 ground states.
Jothinathan, Lakshmi; Hu, Jiangyong
2018-05-01
In this study, the performance of graphene oxide (GO) in ozonation process was kinetically evaluated using the modified R ct concept since GO may act as initiator, promoter and inhibitor in ozone radical chain reaction. The applicability of the modified R ct concept was demonstrated using different GO suspensions (GO alone, GO/TiO 2 , GO/Fe 3 O 4 , GO/TiO 2 /Fe 3 O 4 ) in ozonation process. Results showed that ozone exposure and •OH exposure were found to be higher for GO/Fe 3 O 4 and GO/TiO 2 /Fe 3 O 4 compared to other GO suspensions, which was almost equivalent to O 3 /H 2 O 2 process. The determined initiation and inhibition rate constants of GO alone, were 1 fold higher than GO/Fe 3 O 4 and GO/TiO 2 /Fe 3 O 4 , since the GO alone suspension possesses higher O 3 decomposition but lower organic degradation because that GO does not yield •OH. Moreover, GO/Fe 3 O 4 suspension, along with natural organic matter (NOM), was proven to be helpful in degrading ibuprofen in ozonation process, but the effect was minimal when compared to O 3 /H 2 O 2 process. These results exhibited that the surface modified GO suspensions could be utilized as future alternative AOPs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wyatt, S K; Barck, K H; Kates, L; Zavala-Solorio, J; Ross, J; Kolumam, G; Sonoda, J; Carano, R A D
2015-11-01
The ability to non-invasively measure body composition in mouse models of obesity and obesity-related disorders is essential for elucidating mechanisms of metabolic regulation and monitoring the effects of novel treatments. These studies aimed to develop a fully automated, high-throughput micro-computed tomography (micro-CT)-based image analysis technique for longitudinal quantitation of adipose, non-adipose and lean tissue as well as bone and demonstrate utility for assessing the effects of two distinct treatments. An initial validation study was performed in diet-induced obesity (DIO) and control mice on a vivaCT 75 micro-CT system. Subsequently, four groups of DIO mice were imaged pre- and post-treatment with an experimental agonistic antibody specific for anti-fibroblast growth factor receptor 1 (anti-FGFR1, R1MAb1), control immunoglobulin G antibody, a known anorectic antiobesity drug (rimonabant, SR141716), or solvent control. The body composition analysis technique was then ported to a faster micro-CT system (CT120) to markedly increase throughput as well as to evaluate the use of micro-CT image intensity for hepatic lipid content in DIO and control mice. Ex vivo chemical analysis and colorimetric analysis of the liver triglycerides were performed as the standard metrics for correlation with body composition and hepatic lipid status, respectively. Micro-CT-based body composition measures correlate with ex vivo chemical analysis metrics and enable distinction between DIO and control mice. R1MAb1 and rimonabant have differing effects on body composition as assessed by micro-CT. High-throughput body composition imaging is possible using a modified CT120 system. Micro-CT also provides a non-invasive assessment of hepatic lipid content. This work describes, validates and demonstrates utility of a fully automated image analysis technique to quantify in vivo micro-CT-derived measures of adipose, non-adipose and lean tissue, as well as bone. These body composition metrics highly correlate with standard ex vivo chemical analysis and enable longitudinal evaluation of body composition and therapeutic efficacy monitoring.
Cha, Jungwon; Farhangi, Mohammad Mehdi; Dunlap, Neal; Amini, Amir A
2018-01-01
We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion information within a signed distance function representation to permit more accurate and automated segmentation and tracking of lung nodules in 4D CT data. Active shape models (ASM) with signed distance function were used to capture the shape prior information, preventing unwanted surrounding tissues from becoming part of the segmented object. The optical flow method was used to estimate the local motion and to extend three-dimensional (3D) segmentation to 4D by warping a prior shape model through time. The algorithm has been applied to segmentation of well-circumscribed, vascularized, and juxtapleural lung nodules from respiratory gated CT data. In all cases, 4D segmentation and tracking for five phases of high-resolution CT data took approximately 10 min on a PC workstation with AMD Phenom II and 32 GB of memory. The method was trained based on 500 breath-held 3D CT data from the LIDC data base and was tested on 17 4D lung nodule CT datasets consisting of 85 volumetric frames. The validation tests resulted in an average Dice Similarity Coefficient (DSC) = 0.68 for all test data. An important by-product of the method is quantitative volume measurement from 4D CT from end-inspiration to end-expiration which will also have important diagnostic value. The algorithm performs robust segmentation of lung nodules from 4D CT data. Signed distance ASM provides the shape prior information which based on the iterative graph-cuts framework is adaptively refined to best fit the input data, preventing unwanted surrounding tissue from merging with the segmented object. © 2017 American Association of Physicists in Medicine.
Multimodality image integration for radiotherapy treatment: an easy approach
NASA Astrophysics Data System (ADS)
Santos, Andres; Pascau, Javier; Desco, Manuel; Santos, Juan A.; Calvo, Felipe A.; Benito, Carlos; Garcia-Barreno, Rafael
2001-05-01
The interest of using combined MR and CT information for radiotherapy planning is well documented. However, many planning workstations do not allow to use MR images, nor import predefined contours. This paper presents a new simple approach for transferring segmentation results from MRI to a CT image that will be used for radiotherapy planning, using the same original CT format. CT and MRI images of the same anatomical area are registered using mutual information (MI) algorithm. Targets and organs at risk are segmented by the physician on the MR image, where their contours are easy to track. A locally developed software running on PC is used for this step, with several facilities for the segmentation process. The result is transferred onto the CT by slightly modifying up and down the original Hounsfield values of some points of the contour. This is enough to visualize the contour on the CT, but does not affect dose calculations. The CT is then stored using the original file format of the radiotherapy planning workstation, where the technician uses the segmented contour to design the correct beam positioning. The described method has been tested in five patients. Simulations and patient results show that the dose distribution is not affected by the small modification of pixels of the CT image, while the segmented structures can be tracked in the radiotherapy planning workstation-using adequate window/level settings. The presence of the physician is not requires at the planning workstation, and he/she can perform the segmentation process using his/her own PC. This new approach makes it possible to take advantage from the anatomical information present on the MRI and to transfer the segmentation to the CT used for planning, even when the planning workstation does not allow to import external contours. The physician can draw the limits of the target and areas at risk off-line, thus separating in time the segmentation and planning tasks and increasing the efficiency.
Deniaud, François; Scieux, Catherine; Spindler, Edith; Janier, Michel
2003-09-20
Chlamydia trachomatis (CT) pharyngitis has rarely been described in the literature. Studies in the last decade have shown a prevalence of less than 5%, with more women than men infected in the pharynx. Among homosexual men, only one study, conducted more than 5 years ago, detected the presence of CT in the throat (in one patient out of 13 tested). A 33 year-old homosexual man consulted for cutaneous lesions on the palms and the chest. Infected by HIV, he was taking antiretroviral therapy but no antibiotic prophylaxis. He admitted practising unprotected (insertive and receptive) fellatio with unknown partners. The lesions were those of secondary syphilis but the location of the chancre remained unknown. An enlarged screening for sexually transmitted infections detected the presence, through molecular amplification, of CT in the throat without further localisation (urethra, anus). After intramuscular injection of Extencillin and an 8-day-regimen of cycline, CT was no longer detected in the throat. The course of HIV infection did not appear modified by this infectious episode. According to a review of the literature, the 4 most recent studies have not revealed CT in the throat of homosexuals although the bacteria was detected in the urethra of 3 to 4% of them. Chlamydia trachomatis is more frequently detected in the genital tract rather than the pharynx of women also screened in various localisations. These results must be tempered by the participant recruitment methods, diagnostic methods used, sample size and history of recent antibiotherapy. The pharyngeal mucosa might be less receptive to CT than the urethral mucosa. Association of CT pharyngitis with syphilis or its occurrence during HIV infection are not documented. The molecular amplification technique detects CT in the throat with sensitivity and specificity. A one-week regimen of cycline can cure this pharyngitis. Cost-effectiveness of screening for pharyngeal CT has not yet been assessed in persons 'at risk'.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigro, D.N.
1979-07-01
The quarterly status report covers the period from 30 April 1979 through 31 July 1979 and is a summary of DDA activities for the effort performed on the procurement and delivery of eleven (11) Allison GT 404-4 gas turbine engines and five (5) HT740CT and six (6) V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of eleven (11) Allison GT 404-4 Industrial Gas Turbine Engines and five (5) HT740CT and six (6) V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installationmore » drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE at a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines will be built with ceramic regenerators. (TFD)« less
Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi
2017-05-01
Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.
NASA Astrophysics Data System (ADS)
Hor, Amy; Dagel, Daryl; Luu, Quocanh; Savaikar, Madhusudan; Ding, Shi-You; Smith, Steve
2015-03-01
Photo Activated Localization Microscopy (PALM) is used to conduct an in vivo study of the binding affinity of polysaccharide-specific Carbohydrate Binding Modules (CBMs) to insoluble cellulose substrates. Two families of CBMs, namely TrCBM1 and CtCBM3, were modified to incorporate photo-activatable mCherry fluorescent protein (PAmCherry), and exposed to highly crystalline Valonia cellulose nano-fibrils. The resulting PALM images show CBMs binding along the nano-fibril long axis in a punctuated linear array, localized with, on average, 10 nm precision. Statistical analysis of the binding events results in nearest neighbor distributions between CBMs. A comparison between TrCBM1 and CtCBM3 reveals a similarity in the nearest neighbor distribution peaks but differences in the overall binding density. The former is attributed to steric hindrance among the CBMs on the nano-fibril whereas the latter is attributed to differences in the CBMs' binding strength. These results are compared to similar distributions derived from TEM measurements of dried samples of CtCBM3-CdSs quantum dot bioconjugates and AFM images of CtCBM3-GFP bound to similar Valonia nano-fibrils. Funding provided by NSF MPS/DMR/BMAT Award # 1206908.
Sultan, H; Boyle, A; Pereira, M; Antoun, N; Maimaris, C
2004-01-01
Objective: : In 2002 a new protocol was introduced based on the Canadian CT rules. Before this the Royal College of Surgeons "Galasko" report guidelines had been followed. This study evaluates the effects of the protocol and discusses the impact of the implementation of the NICE head injury guidelines—also based on the Canadian CT rules. Methods: A "before and after" study was undertaken, using data from accident and emergency cards and hospital notes of adult patients with head injuries presenting to the emergency department over seven months in 2001 and nine months in 2002. The two groups were compared to see how rates of computed tomography (CT), admission for observation, discharge, and skull radiography had changed after introduction of the protocol. Results: : Head CT rates in patients with minor head injuries (MHI) increased significantly from 47 of 330 (14%) to 58 of 267 (20%) (p<0.05). There were also significantly increased rates of admission for observation, from 111 (34%) to 119 (45%). Skull radiography rates fell considerably from 33% of all patients with head injuries in 2001 to 1.6% in 2002, without any adverse effect. Conclusions: This study shows that it is possible to replace the current practice in the UK of risk stratification of adult MHI based on skull radiography, with slightly modified versions of the Canadian CT rule/NICE guidelines. This will result in a large reduction in skull radiography and will be associated with modest increases in CT and admissions rates. If introduction of the NICE guideline is to be realistic, the study suggests that it will not be cost neutral. PMID:15208222
Black Hole Sign Predicts Poor Outcome in Patients with Intracerebral Hemorrhage.
Li, Qi; Yang, Wen-Song; Chen, Sheng-Li; Lv, Fu-Rong; Lv, Fa-Jin; Hu, Xi; Zhu, Dan; Cao, Du; Wang, Xing-Chen; Li, Rui; Yuan, Liang; Qin, Xin-Yue; Xie, Peng
2018-01-01
In spontaneous intracerebral hemorrhage (ICH), black hole sign has been proposed as a promising imaging marker that predicts hematoma expansion in patients with ICH. The aim of our study was to investigate whether admission CT black hole sign predicts hematoma growth in patients with ICH. From July 2011 till February 2016, patients with spontaneous ICH who underwent baseline CT scan within 6 h of symptoms onset and follow-up CT scan were recruited into the study. The presence of black hole sign on admission non-enhanced CT was independently assessed by 2 readers. The functional outcome was assessed using the modified Rankin Scale (mRS) at 90 days. Univariate and multivariable logistic regression analyses were performed to assess the association between the presence of the black hole sign and functional outcome. A total of 225 patients (67.6% male, mean age 60.3 years) were included in our study. Black hole sign was identified in 32 of 225 (14.2%) patients on admission CT scan. The multivariate logistic regression analysis demonstrated that age, intraventricular hemorrhage, baseline ICH volume, admission Glasgow Coma Scale score, and presence of black hole sign on baseline CT independently predict poor functional outcome at 90 days. There are significantly more patients with a poor functional outcome (defined as mRS ≥4) among patients with black hole sign than those without (84.4 vs. 32.1%, p < 0.001; OR 8.19, p = 0.001). The CT black hole sign independently predicts poor outcome in patients with ICH. Early identification of black hole sign is useful in prognostic stratification and may serve as a potential therapeutic target for anti-expansion clinical trials. © 2018 S. Karger AG, Basel.
development projects. This shapefile was generated from a raster dataset with a 200 m resolution, in a UTM Energy ("DOE"). The user is granted the right, without any fee or cost, to use, copy, modify appears in all copies of the data. Further, the user of this data agrees to credit NREL in any
18F-FDG positron emission tomography/computed tomography in infective endocarditis.
Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla
2017-02-01
The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.
Diamond, Keri; Mowszowski, Loren; Cockayne, Nicole; Norrie, Louisa; Paradise, Matthew; Hermens, Daniel F; Lewis, Simon J G; Hickie, Ian B; Naismith, Sharon L
2015-01-01
With the rise in the ageing population and absence of a cure for dementia, cost-effective prevention strategies for those 'at risk' of dementia including those with depression and/or mild cognitive impairment are urgently required. This study evaluated the efficacy of a multifaceted Healthy Brain Ageing Cognitive Training (HBA-CT) program for older adults 'at risk' of dementia. Using a single-blinded design, 64 participants (mean age = 66.5 years, SD = 8.6) were randomized to an immediate treatment (HBA-CT) or treatment-as-usual control arm. The HBA-CT intervention was conducted twice-weekly for seven weeks and comprised group-based psychoeducation about cognitive strategies and modifiable lifestyle factors pertaining to healthy brain ageing, and computerized cognitive training. In comparison to the treatment-as-usual control arm, the HBA-CT program was associated with improvements in verbal memory (p = 0.03), self-reported memory (p = 0.03), mood (p = 0.01), and sleep (p = 0.01). While the improvements in memory (p = 0.03) and sleep (p = 0.02) remained after controlling for improvements in mood, only a trend in verbal memory improvement was apparent after controlling for sleep. The HBA-CT program improves cognitive, mood, and sleep functions in older adults 'at risk' of dementia, and therefore offers promise as a secondary prevention strategy.
Ceresoli, Giovanni Luca; Cattaneo, Giovanni Mauro; Castellone, Pietro; Rizzos, Giovanna; Landoni, Claudio; Gregorc, Vanesa; Calandrino, Riccardo; Villa, Eugenio; Messa, Cristina; Santoro, Armando; Fazio, Ferruccio
2007-01-01
Mediastinal elective node irradiation (ENI) in patients with non-small cell lung cancer candidate to radical radiotherapy is controversial. In this study, the impact of co-registered [18F]fluorodeoxyglucose-positron emission tomography (PET) and standard computed tomography (CT) on definition of target volumes and toxicity parameters was evaluated, by comparison with standard CT-based simulation with and without ENI. CT-based gross tumor volume (GTVCT) was first contoured by a single observer without knowledge of PET results. Subsequently, the integrated GTV based on PET/CT coregistered images (GTVPET/CT) was defined. Each patient was planned according to three different treatment techniques: 1) radiotherapy with ENI using the CT data set alone (ENI plan); 2) radiotherapy without ENI using the CT data set alone (no ENI plan); 3) radiotherapy without ENI using PET/CT fusion data set (PET plan). Rival plans were compared for each patient with respect to dose to the normal tissues (spinal cord, healthy lungs, heart and esophagus). The addition of PET-modified TNM staging in 10/21 enrolled patients (48%); 3/21 were shifted to palliative treatment due to detection of metastatic disease or large tumor not amenable to high-dose radiotherapy. In 7/18 (39%) patients treated with radical radiotherapy, a significant (> or =25%) change in volume between GTVCT and GTVPET/CT was observed. For all the organs at risk, ENI plans had dose values significantly greater than no-ENI and PET plans. Comparing no ENI and PET plans, no statistically significant difference was observed, except for maximum point dose to the spinal cord Dmax, which was significantly lower in PET plans. Notably, even in patients in whom PET/CT planning resulted in an increased GTV, toxicity parameters were fairly acceptable, and always more favorable than with ENI plans. Our study suggests that [18F]-fluorodeoxyglucose-PET should be integrated in no-ENI techniques, as it improves target volume delineation without a major increase in predicted toxicity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, Nam Chull, E-mail: pncspine@gmail.com
Background and PurposeIn CT fluoroscopy (CTF)-guided cervical transforaminal epidural steroid injection (TFESI), the majority of radiation dose is contributed by the planning CT scan rather than the CTF procedure itself. We replaced the planning helical CT with a spot CTF and accordingly changed the patient posture during scout and planning scans. The aim of this study was to test whether radiation dose reduction would be achieved by this protocol modification while still maintaining technical performance.MethodsOverall, 338 consecutive procedures before (control group: n = 163) and after (study group: n = 175) instituting the above-mentioned protocol modification were analyzed retrospectively, comparing patient characteristics (age, sex,more » neck diameter, and level injected) and technical performance [technical success rate, dose-length product (DLP), inadvertent contrast flow incidence, number of CTF acquisitions, and procedural time] between the two groups.ResultsAll injections were technically successful at every level from C3–C4 to C7–T1 without serious complications in both groups. The median DLP of the study group (7.92 mGy·cm) was significantly reduced compared to that of the control group (39.05 mGy·cm, P < 0.001). There were no significant differences between the two groups regarding the incidence of inadvertent contrast flow (20.6 vs. 17.2 %, P = 0.426), number of CTF acquisitions (median 5 vs. 4, P = 0.123), and the procedural time (median 6.62 vs. 6.90 min, P = 0.100).ConclusionsWhen conducting CTF-guided cervical TFESIs, a significant radiation dose reduction (median 79.7 % in DLP) can be achieved by modifying scout and planning steps, without compromising the technical performance.« less
Peng, Chen; Li, Kangan; Cao, Xueyan; Xiao, Tingting; Hou, Wenxiu; Zheng, Linfeng; Guo, Rui; Shen, Mingwu; Zhang, Guixiang; Shi, Xiangyang
2012-11-07
We report a facile approach to forming dendrimer-stabilized gold nanoparticles (Au DSNPs) through the use of amine-terminated fifth-generation poly(amidoamine) (PAMAM) dendrimers modified by diatrizoic acid (G5.NH(2)-DTA) as stabilizers for enhanced computed tomography (CT) imaging applications. In this study, by simply mixing G5.NH(2)-DTA dendrimers with gold salt in aqueous solution at room temperature, dendrimer-entrapped gold nanoparticles (Au DENPs) with a mean core size of 2.5 nm were able to be spontaneously formed. Followed by an acetylation reaction to neutralize the dendrimer remaining terminal amines, Au DSNPs with a mean size of 6 nm were formed. The formed DTA-containing [(Au(0))(50)-G5.NHAc-DTA] DSNPs were characterized via different techniques. We show that the Au DSNPs are colloid stable in aqueous solution under different pH and temperature conditions. In vitro hemolytic assay, cytotoxicity assay, flow cytometry analysis, and cell morphology observation reveal that the formed Au DSNPs have good hemocompatibility and are non-cytotoxic at a concentration up to 3.0 μM. X-ray absorption coefficient measurements show that the DTA-containing Au DSNPs have enhanced attenuation intensity, much higher than that of [(Au(0))(50)-G5.NHAc] DENPs without DTA or Omnipaque at the same molar concentration of the active element (Au or iodine). The formed DTA-containing Au DSNPs can be used for CT imaging of cancer cells in vitro as well as for blood pool CT imaging of mice in vivo with significantly improved signal enhancement. With the two radiodense elements of Au and iodine incorporated within one particle, the formed DTA-containing Au DSNPs may be applicable for CT imaging of various biological systems with enhanced X-ray attenuation property and detection sensitivity.
Tungsten Oxide Nanorods: An Efficient Nanoplatform for Tumor CT Imaging and Photothermal Therapy
Zhou, Zhiguo; Kong, Bin; Yu, Chao; Shi, Xiangyang; Wang, Mingwei; Liu, Wei; Sun, Yanan; Zhang, Yingjian; Yang, Hong; Yang, Shiping
2014-01-01
We report here a facile thermal decomposition approach to creating tungsten oxide nanorods (WO2.9 NRs) with a length of 13.1 ± 3.6 nm and a diameter of 4.4 ± 1.5 nm for tumor theranostic applications. The formed WO2.9 NRs were modified with methoxypoly(ethylene glycol) (PEG) carboxyl acid via ligand exchange to have good water dispersability and biocompatibility. With the high photothermal conversion efficiency irradiated by a 980 nm laser and the better X-ray attenuation property than clinically used computed tomography (CT) contrast agent Iohexol, the formed PEGylated WO2.9 NRs are able to inhibit the growth of the model cancer cells in vitro and the corresponding tumor model in vivo, and enable effective CT imaging of the tumor model in vivo. Our “killing two birds with one stone” strategy could be extended for fabricating other nanoplatforms for efficient tumor theranostic applications. PMID:24413483
Ghatpande, A S; Rao, S; Sikdar, S K
2001-01-01
Tetrapentylammonium (TPeA) block of rat brain type IIA sodium channel α subunit was studied using whole cell patch clamp. Results indicate that TPeA blocks the inactivating brain sodium channel in a potential and use-dependent manner similar to that of the cardiac sodium channel. Removal of inactivation using chloramine-T (CT) unmasks a time-dependent block by TPeA consistent with slow blocking kinetics. On the other hand, no time dependence is observed when inactivation is abolished by modification with veratridine. TPeA does not bind in a potential-dependent fashion to veratridine-modified channels and does not significantly affect gating of veratridine-modified channels suggesting that high affinity binding of TPeA to the brain sodium channel is lost after veratridine modification. PMID:11309247
Evaluation of inflammatory activity in Crohn’s disease and ulcerative colitis
Vilela, Eduardo Garcia; Torres, Henrique Osvaldo da Gama; Martins, Fabiana Paiva; Ferrari, Maria de Lourdes de Abreu; Andrade, Marcella Menezes; da Cunha, Aloísio Sales
2012-01-01
Crohn’s disease and ulcerative colitis evolve with a relapsing and remitting course. Determination of inflammatory state is crucial for the assessment of disease activity and for tailoring therapy. However, no simple diagnostic test for monitoring intestinal inflammation is available. Noninvasive markers give only indirect assessments of disease activity. Histopathological or endoscopical examinations accurately assess inflammatory activity, but they are invasive, time consuming and expensive and therefore are unsuitable for routine use. Imaging procedures are not applicable for ulcerative colitis. The usefulness of ultrasound and Doppler imaging in assessing disease activity is still a matter of discussion for Crohn’s disease, and an increased interest in computed tomography enterograph (CTE) has been seen, mainly because it can delineate the extent and severity of bowel wall inflammation, besides detecting extraluminal findings. Until now, the available data concerning the accuracy of magnetic resonance enterography in detecting disease activity is less than CTE. Due to this, clinical activity indices are still commonly used for both diseases. PMID:22408345
Wolthaus, J W H; Sonke, J J; van Herk, M; Damen, E M F
2008-09-01
lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods < 0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of "shape differences" was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.
García-Pedraza, José Ángel; García, Mónica; Martín, María Luisa; Eleno, Nélida; Morán, Asunción
2017-01-01
5-Hydroxytryptamine (5-HT) modulates the cardiac parasympathetic neurotransmission, inhibiting the bradyarrhythmia by 5-HT2 receptor activation. We aimed to determine whether the chronic selective 5-HT2 blockade (sarpogrelate) could modify the serotonergic modulation on vagal cardiac outflow in pithed rat. Bradycardic responses in rats treated with sarpogrelate (30 mg·kg·d; orally) were obtained by electrical stimulation of the vagal fibers (3, 6, and 9 Hz) or intravenous (IV) injections of acetylcholine (1, 5, and 10 μg/kg). 5-HT7 receptor expression was quantified by Western blot in vagus nerve and right atrium. The IV administration of 5-HT (10-200 μg/kg) dose dependently decreased the vagally induced bradycardia, and agonists 5-CT (5-HT1/7), 8-OH-DPAT (5-HT1A), or AS-19 (5-HT7) (50 μg/kg each) mimicked the 5-HT-induced inhibitory effect. Neither agonists CGS-12066B (5-HT1B), L-694,247 (5-HT1D), nor 1-phenylbiguanide (5-HT3) modified the electrically-induced bradycardic responses. Moreover, SB-258719 (5-HT7 antagonist) abolished the 5-HT-, 5-CT-, 8-OH-DPAT-, and AS-19-induced bradycardia inhibition; 5-HT or AS-19 did not modify the bradycardia induced by IV acetylcholine; and 5-HT7 receptor was expressed in both the vagus nerve and the right atrium. Our outcomes suggest that blocking chronically 5-HT2 receptors modifies the serotonergic influence on cardiac vagal neurotransmission exhibiting 5-HT as an exclusively inhibitory agent via prejunctional 5-HT7 receptor.
Kim, Chang Guhn; Kim, Woo Hyoung; Kim, Myoung Hyoun; Kim, Dae-Weung
2013-06-01
The purpose of this study was to estimate lean body mass (LBM) using CT (LBM CTs) and compare the results with LBM estimates of four different predictive equations (LBM PEs) to assess whether LBM CTs and LBM PEs can be used interchangeably for SUV normalization. Whole-body F-18 FDG PET/CT studies were conducted on 392 patients. LBM CT1 is modified adipose tissue-free body mass, and LBM CT2 is adipose tissue-free body mass. Four different PEs were used for comparison (LBM PE1-4). Agreement between the two measurement methods was assessed by Bland-Altman analysis. We calculated the difference between two methods (bias), the percentage of difference, and the limits of agreement, expressed as a percentage. For LBM CTs vs. LBM PEs, except LBM PE3, the ranges of biases and limits of agreement were -3.77 to 3.81 kg and 26.60-35.05 %, respectively, indicating the wide limits of agreement and differing magnitudes of bias. For LBM CTs vs. LBM PE3, LBM PE3 had wider limits of agreement and greater positive bias (44.28-46.19 % and 10.49 to 14.04 kg, respectively), showing unacceptably large discrepancies between LBM CTs and LBM PE3. This study demonstrated that there are substantial discrepancies between individual LBM CTs and LBM PEs, and this should be taken into account when LBM CTs and LBM PEs are used interchangeably between patients.
Lu, Michael T; Hallett, Travis R; Hemingway, Jennifer; Hughes, Danny R; Hoffmann, Udo; Duszak, Richard
2016-09-01
Secondary interpretation of diagnostic imaging examinations (providing a second formal interpretation for imaging performed at another institution) may reduce repeat imaging after transfer of care. Recently, CMS requested information to guide payment policy. We aimed to study historic trends in submitted claims and payments for secondary interpretation services in the Medicare fee-for-service population. Applying current procedural terminology codes by body part to Medicare Part B aggregate claims files, we identified all CT interpretation services rendered between 1999 and 2012. Secondary interpretation services were identified using combined code modifiers 26 and 77, in accordance with CMS billing guidelines. The frequencies of billed and denied services were extracted for primary and secondary CT interpretation services. Primary versus secondary interpretation denial rates were calculated and compared. Of all 227 million Medicare Part B claims for CT services, 299,468 (0.13%) were for secondary interpretation services. From 1999 to 2012, growth in secondary interpretation claims outpaced that in primary interpretation claims (+811% versus +56%; compound annual growth rate 17% versus 3.2%). As a percentage of all services, secondary interpretations increased from 0.05% in 1999 to 0.30% in 2012. Denial rates for second interpretations decreased from 1999 to 2012 (12.7% to 7.0%), and now approach those for primary interpretations (5.4% in 2012). Medicare claims for secondary interpretation of CT examinations are growing but account for less than 1% of all billed CT interpretation services. Denial rates are similar to those of primary interpretation services. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Intravenous volume tomographic pulmonary angiography imaging
NASA Astrophysics Data System (ADS)
Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng
1999-05-01
This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chao, M; Yuan, Y; Lo, Y
Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered withmore » the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.« less
Gómez-de la Fuente, F J; Martínez-Rodríguez, I; de Arcocha-Torres, M; Quirce, R; Jiménez-Bonilla, J; Martínez-Amador, N; Banzo, I
11 C-choline PET/CT has demonstrated good results in the restaging of prostate cancer (PCa) with high serum prostate specific antigen (PSA), but its use in patients with low serum PSA is controversial. Our aim was to evaluate the contribution of 11 C-choline PET/CT in patients with PCa, biochemical relapse and PSA <1 ng/ml. Fifty consecutive patients (mean age: 65.9±5.6 years) with biochemical relapse of PCa and serum PSA <1ng/ml were evaluated retrospectively. PET/CT was performed 20min after intravenous administration of 555-740 MBq of 11 C-choline. Minimum follow up time was 30 months. Twenty-one out of 50 patients (42%) had an abnormal 11 C-choline PET/CT. In 7 out of 21 patients (14%) tumor was confirmed (4 in prostatic bed, 4 in pelvic lymph nodes, 2 in mediastinal lymph nodes and one synchronous sigmoid carcinoma), and in all cases the initial therapeutic planning was modified. In 2 patients (4%) subsequent tests diagnosed a benign disease (one sarcoidosis, one tuberculosis sequelae) and in 3 patients (6%) they ruled out pathology. The other 9 patients (18%) had no further assessment (7 mediastinal and 4 pelvic lymph nodes). Twenty-nine out of 50 patients (58%) had a normal PET/CT. At 30 months, follow up recurrence was confirmed only in 2 of these patients. 11 C-choline PET/CT proved its usefulness in demonstrating tumor in 14% of patients with BR of PCa and serum PSA <1ng/ml, with therapeutic implications. In 4% of patients a benign condition was detected. A normal 11 C-choline PET/CT was associated with a very low rate of recurrence at 30 months. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Pallesen, Lars P; Khomenko, Andrei; Dzialowski, Imanuel; Barlinn, Jessica; Barlinn, Kristian; Zerna, Charlotte; van der Hoeven, Erik Jrj; Algra, Ale; Kapelle, L Jaap; Michel, Patrik; Bodechtel, Ulf; Demchuk, Andrew M; Schonewille, Wouter; Puetz, Volker
2017-02-01
Background Coma is associated with poor outcome in patients with basilar artery occlusion. Aims We sought to assess whether the posterior circulation Acute Stroke Prognosis Early CT Score and the Pons-Midbrain Index applied to CT angiography source images predict the outcome of comatose patients in the Basilar Artery International Cooperation Study. Methods Basilar Artery International Cooperation Study was a prospective, observational registry of patients with acute basilar artery occlusion with 48 recruiting centers worldwide. We applied posterior circulation Acute Stroke Prognosis Early CT Score and Pons-Midbrain Index to CT angiography source images of Basilar Artery International Cooperation Study patients who presented with coma. We calculated adjusted risk ratios to assess the association of dichotomized posterior circulation Acute Stroke Prognosis Early CT Score (≥8 vs. <8) and Pons-Midbrain Index (<3 vs. ≥3) with mortality and favourable outcome (modified Rankin Scale score 0-3) at one month. Results Of 619 patients in the Basilar Artery International Cooperation Study registry, CT angiography source images were available for review in 158 patients. Among these, 78 patients (49%) presented with coma. Compared to non-comatose patients, comatose patients were more likely to die (risk ratios 2.34; CI 95% 1.56-3.52) and less likely to have a favourable outcome (risk ratios 0.44; CI 95% 0.24-0.80). Among comatose patients, a Pons-Midbrain Index < 3 was related to reduced mortality (adjusted RR 0.66; 95% CI 0.46-0.96), but not to favourable outcome (adjusted RR 1.19; 95% CI 0.39-3.62). Posterior circulation Acute Stroke Prognosis Early CT Score dichotomized at ≥ 8 vs. <8 was not significantly associated with death (adjusted RR 0.70; 95% CI 0.46-1.05). Conclusion In comatose patients with basilar artery occlusion, the extent of brainstem ischemia appears to be related to mortality but not to favourable outcome.
Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT
NASA Astrophysics Data System (ADS)
Krol, Andrzej; Naveed, Muhammad; McGrath, Mary; Lisi, Michele; Lavalley, Cathy; Feiglin, David
2015-03-01
The aim of this study was to evaluate if effective radiation dose due to PET component in adult whole-body tumor imaging with time-of-flight F-18 FDG PET/CT could be significantly reduced. We retrospectively analyzed data for 10 patients with the body mass index ranging from 25 to 50. We simulated F-18 FDG dose reduction to 25% of the ACR recommended dose via reconstruction of simulated shorter acquisition time per bed position scans from the acquired list data. F-18 FDG whole-body scans were reconstructed using time-of-flight OSEM algorithm and advanced system modeling. Two groups of images were obtained: group A with a standard dose of F-18 FDG and standard reconstruction parameters and group B with simulated 25% dose and modified reconstruction parameters, respectively. Three nuclear medicine physicians blinded to the simulated activity independently reviewed the images and compared diagnostic quality of images. Based on the input from the physicians, we selected optimal modified reconstruction parameters for group B. In so obtained images, all the lesions observed in the group A were visible in the group B. The tumor SUV values were different in the group A, as compared to group B, respectively. However, no significant differences were reported in the final interpretation of the images from A and B groups. In conclusion, for a small number of patients, we have demonstrated that F-18 FDG dose reduction to 25% of the ACR recommended dose, accompanied by appropriate modification of the reconstruction parameters provided adequate diagnostic quality of PET images acquired on time-of-flight PET/CT.
Feature and Intensity Based Medical Image Registration Using Particle Swarm Optimization.
Abdel-Basset, Mohamed; Fakhry, Ahmed E; El-Henawy, Ibrahim; Qiu, Tie; Sangaiah, Arun Kumar
2017-11-03
Image registration is an important aspect in medical image analysis, and kinds use in a variety of medical applications. Examples include diagnosis, pre/post surgery guidance, comparing/merging/integrating images from multi-modal like Magnetic Resonance Imaging (MRI), and Computed Tomography (CT). Whether registering images across modalities for a single patient or registering across patients for a single modality, registration is an effective way to combine information from different images into a normalized frame for reference. Registered datasets can be used for providing information relating to the structure, function, and pathology of the organ or individual being imaged. In this paper a hybrid approach for medical images registration has been developed. It employs a modified Mutual Information (MI) as a similarity metric and Particle Swarm Optimization (PSO) method. Computation of mutual information is modified using a weighted linear combination of image intensity and image gradient vector flow (GVF) intensity. In this manner, statistical as well as spatial image information is included into the image registration process. Maximization of the modified mutual information is effected using the versatile Particle Swarm Optimization which is developed easily with adjusted less parameter. The developed approach has been tested and verified successfully on a number of medical image data sets that include images with missing parts, noise contamination, and/or of different modalities (CT, MRI). The registration results indicate the proposed model as accurate and effective, and show the posture contribution in inclusion of both statistical and spatial image data to the developed approach.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Background Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson’s disease (PD). Methods We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. Results The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. Conclusion CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable. PMID:26147749
Grotzky, Andrea; Manaka, Yuichi; Kojima, Taisuke; Walde, Peter
2011-01-10
Covalent UV/vis-quantifiable bis-aryl hydrazone bond formation was investigated for the preparation of conjugates between α-poly-d-lysine (PDL) and either α-chymotrypsin (α-CT) or horseradish peroxidase (HRP). PDL and the enzymes were first modified via free amino groups with the linking reagents succinimidyl 6-hydrazinonicotinate acetone hydrazone (S-HyNic, at pH 7.6) and succinimidyl 4-formylbenzoate (S-4FB, at pH 7.2), respectively. The modified PDL and enzymes were then conjugated at pH 4.7, whereby polymer chains carrying several enzymes were obtained. Kinetics of the bis-aryl hydrazone bond formation was investigated spectrophotometrically at 354 nm. Retention of the enzymatic activity after conjugate formation was confirmed by using the substrates N-succinimidyl-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide (for α-CT) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS, for HRP). Thus, not only a mild and efficient preparation and convenient quantification of a conjugate between the polycationic α-polylysine and enzymes could be shown, but also the complete preservation of the enzymatic activity.
Moroncini, Francesca; Mazzoni, Serena; Belicchi, Marzia Laura Chiara; Villa, Chiara; Erratico, Silvia; Colombo, Elena; Calcaterra, Francesca; Brambilla, Lucia; Torrente, Yvan; Albertini, Gianni; Della Bella, Silvia
2014-01-01
Spatiotemporal interactions play important roles in tissue development and function, especially in stem cell-seeded bioscaffolds. Cells interact with the surface of bioscaffold polymers and influence material-driven control of cell differentiation. In vitro cultures of different human progenitor cells, that is, endothelial colony-forming cells (ECFCs) from a healthy control and a patient with Kaposi sarcoma (an angioproliferative disease) and human CD133+ muscle-derived stem cells (MSH 133+ cells), were seeded onto polyglycolic acid–polylactic acid scaffolds. Three-dimensional (3D) images were obtained by X-ray phase-contrast microtomography (micro-CT) and processed with the Modified Bronnikov Algorithm. The method enabled high spatial resolution detection of the 3D structural organization of cells on the bioscaffold and evaluation of the way and rate at which cells modified the construct at different time points from seeding. The different cell types displayed significant differences in the proliferation rate. In conclusion, X-ray synchrotron radiation phase-contrast micro-CT analysis proved to be a useful and sensitive tool to investigate the spatiotemporal pattern of progenitor cell organization on a bioscaffold. PMID:23879738
Improved 2D/3D registration robustness using local spatial information
NASA Astrophysics Data System (ADS)
De Momi, Elena; Eckman, Kort; Jaramaz, Branislav; DiGioia, Anthony, III
2006-03-01
Xalign is a tool designed to measure implant orientation after joint arthroplasty by co-registering a projection of an implant model and a digitally reconstructed radiograph of the patient's anatomy with a post operative x-ray. A mutual information based registration method is used to automate alignment. When using basic mutual information, the presence of local maxima can result in misregistration. To increase robustness of registration, our research is aimed at improving the similarity function by modifying the information measure and incorporating local spatial information. A test dataset with known groundtruth parameters was created to evaluate the performance of this measure. A synthetic radiograph was generated first from a preoperative pelvic CT scan to act as the gold standard. The voxel weights used to generate the image were then modified and new images were generated with the CT rigidly transformed. The roll, pitch and yaw angles span a range of -10/+10 degrees, while x, y and z translations range from -10mm to +10mm. These images were compared with the reference image. The proposed cost function correctly identified the correct pose in all tests and did not exhibit any local maxima which would slow or prevent locating the global maximum.
2017-11-01
CT radiation is arguably carcinogenic. Results from single-centre studies, mostly retrospective, have advocated lowering the CT radiation dose for the diagnosis of appendicitis. However, adoption of low-dose CT has been slow. We aimed to assess the effectiveness of low-dose CT compared with standard-dose CT in the diagnosis of appendicitis in adolescents and young adults. We did this pragmatic, multicentre, randomised controlled non-inferiority trial at 20 South Korean teaching hospitals with little experience with low-dose CT. Patients aged 15-44 years with suspected appendicitis were randomly assigned (1:1), via computer-generated random assignments (permuted block sizes of two, four, six, and eight) concealed in sequentially numbered envelopes, to receive low-dose CT (2 mSv) or standard-dose CT (≤8 mSv). Randomisation was stratified by site. Group allocation was concealed from patients, outcome assessors, and adverse event adjudicators; care providers, site pathologists, and data collectors were aware of allocation. The primary endpoint was the negative (unnecessary) appendectomy rate among all appendectomies, with a non-interiority margin of 4·5% for low-dose versus standard-dose CT. Primary analysis was by modified intention to treat, which included all patients who received an appendectomy in the group to which they were assigned. This trial is registered with ClinicalTrials.gov, number NCT01925014. Between Dec 4, 2013, and Aug 18, 2016, we assigned 1535 patients to the low-dose CT group and 1539 patients to the standard-dose CT group. 22 (3·9%) of 559 patients had a negative appendectomy in the low-dose group versus 16 (2·7%) of 601 patients in the standard-dose group (difference 1·3%, 95% CI -0·8 to 3·3; p=0·0022 for the non-inferiority test). We recorded 43 adverse events in 43 (2·8%) of 1535 patients in the low-dose group and 41 adverse events in 40 (2·6%) of 1539 patients in the standard-dose group. One life-threatening adverse event of anaphylaxis caused by an iodinated contrast material occurred in the low-dose group. Radiation dose of appendiceal CT for adolescents and young adults can be reduced to 2 mSv without impairing clinical outcomes. In view of the vast number of appendiceal CT examinations done worldwide, use of low-dose CT could prevent a sizeable number of radiation-associated cancers in the future. Korea Health Industry Development Institute, Seoul National University Bundang Hospital, Dasol Life Science, and Bracco Imaging Korea. Copyright © 2017 Elsevier Ltd. All rights reserved.
Godar, Sean C; Mosher, Laura J; Strathman, Hunter J; Gochi, Andrea M; Jones, Cori M; Fowler, Stephen C; Bortolato, Marco
2016-07-01
The D1CT-7 mouse is one of the best known animal models of Tourette syndrome (TS), featuring spontaneous tic-like behaviours sensitive to standard TS therapies; these characteristics ensure a high face and predictive validity of this model, yet its construct validity remains elusive. To address this issue, we studied the responses of D1CT-7 mice to two critical components of TS pathophysiology: the exacerbation of tic-like behaviours in response to stress and the presence of sensorimotor gating deficits, which are thought to reflect the perceptual alterations causing the tics. D1CT-7 and wild-type (WT) littermates were subjected to a 20 min session of spatial confinement (SC) within an inescapable, 10 cm wide cylindrical enclosure. Changes in plasma corticosterone levels, tic-like behaviours and other spontaneous responses were measured. SC-exposed mice were also tested for the prepulse inhibition (PPI) of the startle response (a sensorimotor gating index) and other TS-related behaviours, including open-field locomotion, novel object exploration and social interaction and compared with non-confined counterparts. SC produced a marked increase in corticosterone concentrations in both D1CT-7 and WT mice. In D1CT-7, but not WT mice, SC exacerbated tic-like and digging behaviours, and triggered PPI deficits and aggressive responses. Conversely, SC did not modify locomotor activity or novel object exploration in D1CT-7 mice. Both tic-like behaviours and PPI impairments in SC-exposed D1CT-7 mice were inhibited by standard TS therapies and D1 dopamine receptor antagonism. These findings collectively support the translational and construct validity of D1CT-7 mice with respect to TS. This article is part of a themed section on Updating Neuropathology and Neuropharmacology of Monoaminergic Systems. To view the other articles in this section visit http://onlinelibrary.wiley.com/doi/10.1111/bph.v173.13/issuetoc. © 2015 The British Pharmacological Society.
Development of a Carbon Nanotube-Based Micro-CT and its Applications in Preclinical Research
NASA Astrophysics Data System (ADS)
Burk, Laurel May
Due to the dependence of researchers on mouse models for the study of human disease, diagnostic tools available in the clinic must be modified for use on these much smaller subjects. In addition to high spatial resolution, cardiac and lung imaging of mice presents extreme temporal challenges, and physiological gating methods must be developed in order to image these organs without motion blur. Commercially available micro-CT imaging devices are equipped with conventional thermionic x-ray sources and have a limited temporal response and are not ideal for in vivo small animal studies. Recent development of a field-emission x-ray source with carbon nanotube (CNT) cathode in our lab presented the opportunity to create a micro-CT device well-suited for in vivo lung and cardiac imaging of murine models for human disease. The goal of this thesis work was to present such a device, to develop and refine protocols which allow high resolution in vivo imaging of free-breathing mice, and to demonstrate the use of this new imaging tool for the study many different disease models. In Chapter 1, I provide background information about x-rays, CT imaging, and small animal micro-CT. In Chapter 2, CNT-based x-ray sources are explained, and details of a micro-focus x-ray tube specialized for micro-CT imaging are presented. In Chapter 3, the first and second generation CNT micro-CT devices are characterized, and successful respiratory- and cardiac-gated live animal imaging on normal, wild-type mice is achieved. In Chapter 4, respiratory-gated imaging of mouse disease models is demonstrated, limitations to the method are discussed, and a new contactless respiration sensor is presented which addresses many of these limitations. In Chapter 5, cardiac-gated imaging of disease models is demonstrated, including studies of aortic calcification, left ventricular hypertrophy, and myocardial infarction. In Chapter 6, several methods for image and system improvement are explored, and radiation therapy-related micro-CT imaging is present. Finally, in Chapter 7 I discuss future directions for this research and for the CNT micro-CT.
Jia, Fang; Balaji, Baghavathy S; Gallazzi, Fabio; Lewis, Michael R
2015-11-01
The bcl-2 gene is overexpressed in non-Hodgkin's lymphoma (NHL). We have reported micro-SPECT/CT imaging of Mec-1 human lymphoma xenografts in SCID mice, using [(111)In]DOTA-anti-bcl-2-PNA-Tyr(3)-octreotate. In order to reduce normal organ accumulation and improve imaging contrast, modified monomers with neutral hydrophilic (serine, TS) or negatively charged (aspartic acid, TD) residues were synthesized as substitutes for glycine at T(14) in the PNA sequence. The parent and modified PNA-peptide conjugates were labeled with (64)Cu and evaluated in biodistribution studies and high resolution PET/CT imaging of SCID mice bearing bcl-2-positive Mec-1 xenografts as well as bcl-2-negative Ramos xenografts. Mice were administered the (64)Cu-labeled conjugates for biodistribution and imaging studies. Biodistributions were obtained from 1 to 48 h post-injection. Mice were imaged from 1 to 48 h post-injection. The parent glycine conjugate and two modified conjugates all showed selective tumor uptake in Mec-1 xenografts. The liver uptake of the serine conjugate was significantly reduced compared to the two other PNA conjugates. Its kidney uptake was highest of the three at 47.1% ID/g at 1h and dropped to 20.6% ID/g at 24h. [Copper-64]DOTA-anti-bcl-2-TS-PNA-Tyr(3)-octreotate showed tumor uptake of 1.38% ID/g at 1h and 1.06% ID/g at 24h. The tumor-to-blood ratio was increased by factor of 2 from 1h to 24h. This compound detected Mec-1 tumors by micro-PET/CT as early as 1h post-injection and at time points out to 48 h. However, the negative control Ramos tumor could not be detected. These (64)Cu-labeled, amino acid-modified PNA conjugates showed selective tumor targeting in vivo, and tumor xenografts were detected by micro-PET/CT as early as 1h post-injection, suggesting that bcl-2 expression at the mRNA level can detected by PET in mouse models of NHL. Advances in knowledge and implications for patient care Down-regulating bcl-2, an anti-apoptotic proto-oncogene, is a mechanism to reverse chemotherapy resistance in humans with NHL. Thus, bcl-2 overexpression might be considered a new independent prognostic parameter in NHL, aiding in the identification of patients at risk for treatment failure. We have developed [(64)Cu]DOTA-anti-bcl-2-PNA-Tyr(3)-octreotate conjugates for targeted antisense PET imaging. Our preclinical studies identified an effective combination of antisense and radionuclide imaging, with the goal of future clinical trials in patients. This imaging modality may improve clinical care by identifying patients who might respond better to conventional chemotherapy. Copyright © 2015. Published by Elsevier Inc.
Justine, Maria; Manaf, Haidzir; Sulaiman, Affeenddie; Razi, Shahir; Alias, Hani Asilah
2014-01-01
This study compares energy expenditure (EE), gait parameters (GP), and level of fatigue (LOF) between 5-minute walking with sharp turning (ST) and corner turning (CT). Data were obtained from 29 community-dwelling elderly (mean age, 62.7 ± 3.54 years). For 5 minutes, in ST task, participants walked on a 3-meter pathway with 2 cones placed at each end (180° turning), while in CT task, participants walked on a 6-meter pathway with 4 cones placed at 4 corners (90° turning). The physiological cost index, pedometer, and 10-point Modified Borg Dyspnoea Scale were used to measure EE (beats/min), GP (no of steps), and LOF, respectively. Data were analyzed by using independent t-tests. EE during ST (0.62 ± 0.21 beats/min) was significantly higher than CT (0.48 ± 0.17 beats/min) (P < 0.05). GP (434 ± 92.93 steps) and LOF (1.40 ± 1.11) in ST were found to be lower compared to GP (463 ± 92.18 steps) and LOF (1.54 ± 1.34) in CT (All, P > 0.05). Higher EE in ST could be due to the difficulty in changing to a 180° direction, which may involve agility and different turning strategies (step-turn or pivot-turn) to adjust the posture carefully. In CT, participants could choose a step-turn strategy to change to a 90° direction, which was less challenging to postural control.
Romano, Christine A; Sontz, Pamela A; Barton, Jacqueline K
2011-07-12
Endonuclease III (EndoIII) is a base excision repair glycosylase that targets damaged pyrimidines and contains a [4Fe-4S] cluster. We have proposed a model where BER proteins that contain redox-active [4Fe-4S] clusters utilize DNA charge transport (CT) as a first step in the detection of DNA lesions. Here, several mutants of EndoIII were prepared to probe their efficiency of DNA/protein charge transport. Cyclic voltammetry experiments on DNA-modified electrodes show that aromatic residues F30, Y55, Y75, and Y82 help mediate charge transport between DNA and the [4Fe-4S] cluster. On the basis of circular dichroism studies to measure protein stability, mutations at residues W178 and Y185 are found to destabilize the protein; these residues may function to protect the [4Fe-4S] cluster. Atomic force microscopy studies furthermore reveal a correlation in the ability of mutants to carry out protein/DNA CT and their ability to relocalize onto DNA strands containing a single base mismatch; EndoIII mutants that are defective in carrying out DNA/protein CT do not redistribute onto mismatch-containing strands, consistent with our model. These results demonstrate a link between the ability of the repair protein to carry out DNA CT and its ability to relocalize near lesions, thus pointing to DNA CT as a key first step in the detection of base damage in the genome.
Romano, Christine A.; Sontz, Pamela A.; Barton, Jacqueline K.
2011-01-01
Endonuclease III (EndoIII) is a base excision repair glycosylase that targets damaged pyrimidines and contains a [4Fe-4S] cluster. We have proposed a model where BER proteins that contain redox-active [4Fe-4S] clusters utilize DNA charge transport (CT) as a first step in the detection of DNA lesions. Here, several mutants of EndoIII were prepared to probe their efficiency of DNA/protein charge transport. Cyclic voltammetry experiments on DNA-modified electrodes show that aromatic residues F30, Y55, Y75 and Y82 help mediate charge transport between DNA and the [4Fe-4S] cluster. Based on circular dichroism studies to measure protein stability, mutations at residues W178 and Y185 are found to destabilize the protein; these residues may function to protect the [4Fe-4S] cluster. Atomic force microscopy studies furthermore reveal a correlation in the ability of mutants to carry out protein/DNA CT and their ability to relocalize onto DNA strands containing a single base mismatch; EndoIII mutants that are defective in carrying out DNA/protein CT do not redistribute onto mismatch-containing strands, consistent with our model. These results demonstrate a link between the ability of the repair protein to carry out DNA CT and its ability to relocalize near lesions, thus pointing to DNA CT as a key first step in the detection of base damage in the genome. PMID:21651304
Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I
2014-12-01
The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.
A Hybrid Method for Pancreas Extraction from CT Image Based on Level Set Methods
Tan, Hanqing; Fujita, Hiroshi
2013-01-01
This paper proposes a novel semiautomatic method to extract the pancreas from abdominal CT images. Traditional level set and region growing methods that request locating initial contour near the final boundary of object have problem of leakage to nearby tissues of pancreas region. The proposed method consists of a customized fast-marching level set method which generates an optimal initial pancreas region to solve the problem that the level set method is sensitive to the initial contour location and a modified distance regularized level set method which extracts accurate pancreas. The novelty in our method is the proper selection and combination of level set methods, furthermore an energy-decrement algorithm and an energy-tune algorithm are proposed to reduce the negative impact of bonding force caused by connected tissue whose intensity is similar with pancreas. As a result, our method overcomes the shortages of oversegmentation at weak boundary and can accurately extract pancreas from CT images. The proposed method is compared to other five state-of-the-art medical image segmentation methods based on a CT image dataset which contains abdominal images from 10 patients. The evaluated results demonstrate that our method outperforms other methods by achieving higher accuracy and making less false segmentation in pancreas extraction. PMID:24066016
Molar axis estimation from computed tomography images.
Dongxia Zhang; Yangzhou Gan; Zeyang Xia; Xinwen Zhou; Shoubin Liu; Jing Xiong; Guanglin Li
2016-08-01
Estimation of tooth axis is needed for some clinical dental treatment. Existing methods require to segment the tooth volume from Computed Tomography (CT) images, and then estimate the axis from the tooth volume. However, they may fail during estimating molar axis due to that the tooth segmentation from CT images is challenging and current segmentation methods may get poor segmentation results especially for these molars with angle which will result in the failure of axis estimation. To resolve this problem, this paper proposes a new method for molar axis estimation from CT images. The key innovation point is that: instead of estimating the 3D axis of each molar from the segmented volume, the method estimates the 3D axis from two projection images. The method includes three steps. (1) The 3D images of each molar are projected to two 2D image planes. (2) The molar contour are segmented and the contour's 2D axis are extracted in each 2D projection image. Principal Component Analysis (PCA) and a modified symmetry axis detection algorithm are employed to extract the 2D axis from the segmented molar contour. (3) A 3D molar axis is obtained by combining the two 2D axes. Experimental results verified that the proposed method was effective to estimate the axis of molar from CT images.
Creation of a 3D printed temporal bone model from clinical CT data.
Cohen, Joss; Reyes, Samuel A
2015-01-01
Generate and describe the process of creating a 3D printed, rapid prototype temporal bone model from clinical quality CT images. We describe a technique to create an accurate, alterable, and reproducible rapid prototype temporal bone model using freely available software to segment clinical CT data and generate three different 3D models composed of ABS plastic. Each model was evaluated based on the appearance and size of anatomical structures and response to surgical drilling. Mastoid air cells had retained scaffolding material in the initial versions. This required modifying the model to allow drainage of the scaffolding material. External auditory canal dimensions were similar to those measured from the clinical data. Malleus, incus, oval window, round window, promontory, horizontal semicircular canal, and mastoid segment of the facial nerve canal were identified in all models. The stapes was only partially formed in two models and absent in the third. Qualitative feel of the ABS plastic was softer than bone. The pate produced by drilling was similar to bone dust when appropriate irrigation was used. We present a rapid prototype temporal bone model made based on clinical CT data using 3D printing technology. The model can be made quickly and inexpensively enough to have potential applications for educational training. Copyright © 2015 Elsevier Inc. All rights reserved.
Risher, D W; Zhang, X; Kostarczyk, E; Gokin, A P; Honda, C N; Giesler, G J
1997-04-25
We developed a relatively inexpensive method for stereotaxic placement of electrodes or needles in the brains of monkeys. Steel balls were affixed to the skulls of monkeys. These balls served as fiducial markers and were also used as points at which the monkey's skull was held in a modified stereotaxic apparatus. Computed tomography (CT) was used to establish the location of an injection target with respect to the fiducial markers. A computer program related the CT coordinates to stereotaxic coordinates. These were used to direct an electrode marker toward a target in the hypothalamus. With the marker left in place, the monkey was removed from the stereotaxic frame and a second CT scan was performed. Corrections for errors in marker placement were made and retrograde tracers were injected. This procedure was found to be more accurate and reliable than conventional stereotaxic procedures. The accuracy and repeatability of the technique were also established using a phantom model of a monkey's skull. Two important advantages of this method are that animals can be repeatedly placed into the stereotaxic frame in precisely the same position and that there are many opportunities during the procedure to check for and correct errors.
GEANT4 Tuning For pCT Development
NASA Astrophysics Data System (ADS)
Yevseyeva, Olga; de Assis, Joaquim T.; Evseev, Ivan; Schelin, Hugo R.; Paschuk, Sergei A.; Milhoretto, Edney; Setti, João A. P.; Díaz, Katherin S.; Hormaza, Joel M.; Lopes, Ricardo T.
2011-08-01
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. Moreover, the spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through aluminum absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadrontherapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development.
Schreiber, Franziska; Witthöft, Michael; Neng, Julia M B; Weck, Florian
2016-03-01
Previous studies using modified versions of the Affect Misattribution Procedure (AMP; Payne, Cheng, Govorun, & Stewart, 2005) have revealed that there is an implicit negative evaluation bias of illness-related information in patients with hypochondriasis (HYP), which might be a maintaining feature of HYP. However, there is no evidence on whether this bias might be targeted successfully by effective treatments, such as exposure therapy (ET) or cognitive therapy (CT). This is the first study to examine the change in negative implicit evaluations in a randomized controlled trial, including individual CT and ET, compared to a wait-list control group for HYP. An AMP with illness, symptom and neutral primes was used in 70 patients with HYP before and after treatment (wait-list respectively). There was no significant change in negative implicit affective evaluations in both CT and ET, compared to wait-list. However, comparisons between the two active treatments revealed an interaction effect, that only for CT were the affective reactions on illness-as well as symptom-related prime trials (but not neutral primes) significantly more positive at post-compared to pre-treatment. In CT but not in ET, the reduction of implicit negative evaluation bias regarding symptom-related primes was significantly related to the reduction of self-reported health anxiety. The small subsample sizes for CT and ET, in comparison to wait-list, prohibit the detection of smaller effects. Formal cognitive restructuring is necessary for reducing implicit negative evaluation bias in HYP, but the latter is not a prerequisite for reducing health anxiety. Thus, the importance of the negative implicit evaluation bias for the maintenance of HYP remains questionable. Copyright © 2015 Elsevier Ltd. All rights reserved.
Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner
NASA Astrophysics Data System (ADS)
Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.
2006-03-01
We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girinsky, Théodore; Aupérin, Anne; Ribrag, Vincent
2014-08-01
Purpose: This study examines the role of {sup 18}F-labeled fluorodeoxyglucose positron emission tomography (FDG-PET) in the implementation of involved-node radiation therapy (INRT) in patients treated for clinical stages (CS) I/II supradiaphragmatic Hodgkin lymphoma (HL). Methods and Material: Patients with untreated CS I/II HL enrolled in the randomized EORTC/LYSA/FIL Intergroup H10 trial and participating in a real-time prospective quality assurance program were prospectively included in this study. Data were electronically obtained from 18 French cancer centers. All patients underwent APET-computed tomography (PET-CT) and a post-chemotherapy planning CT scanning. The pre-chemotherapy gross tumor volume (GTV) and the postchemotherapy clinical target volume (CTV) weremore » first delineated on CT only by the radiation oncologist. The planning PET was then co-registered, and the delineated volumes were jointly analyzed by the radiation oncologist and the nuclear medicine physician. Lymph nodes undetected on CT but FDG-avid were recorded, and the previously determined GTV and CTV were modified according to FDG-PET results. Results: From March 2007 to February 2010, 135 patients were included in the study. PET-CT identified at least 1 additional FDG-avid lymph node in 95 of 135 patients (70.4%; 95% confidence interval [CI]: 61.9%-77.9%) and 1 additional lymph node area in 55 of 135 patients (40.7%; 95% CI: 32.4%-49.5%). The mean increases in the GTV and CTV were 8.8% and 7.1%, respectively. The systematic addition of PET to CT led to a CTV increase in 60% of the patients. Conclusions: Pre-chemotherapy FDG-PET leads to significantly better INRT delineation without necessarily increasing radiation volumes.« less
Stern, J E; Ladizesky, M G; Keller Sarmiento, M I; Cardinali, D P
1993-03-01
Hypocalcemia is a common finding during stress. The objective of this study was to examine: (a) the changes in circulating calcium, parathyroid hormone (PTH) and calcitonin (CT) concentration in rats stressed by being given a subcutaneous injection of turpentine oil, and (b) the involvement of the sympathetic cervical pathway in stress-induced changes of calcium homeostasis. Four hours after receiving turpentine oil or vehicle, rats were subjected either to hypocalcemia, by being given EDTA intraperitoneally, or to hypercalcemia, by being injected CaCl2 intraperitoneally. Significant changes in serum calcium (10% decrease), serum PTH (28% increase) and CT levels (40% decrease) were observed in stressed rats. EDTA administration brought about a significantly greater hypocalcemia, and a higher PTH secretory response in turpentine oil-stressed rats. During stress, the increase of serum calcium after CaCl2 was significantly smaller, and the rise of CT was greater than in controls. In the case of CT the changes were still observed in rats subjected to superior cervical ganglionectomy (SCGx) 14 days earlier. In the case of PTH, the increase found in stressed rats, but not the augmented response after EDTA, was blunted by SCGx. The potentiation of hypocalcemia brought about by turpentine oil was no longer observed in SCGx rats. In vehicle-treated controls, SCGx delayed PTH response to hypocalcemia, but did not affect the increased response of CT to CaCl2 challenge. The results indicate that a number of changes in calcium homeostasis arise during turpentine oil stress in rats. SCGx was effective to modify the set point for PTH release, but played a minor role in affecting the augmentation of CT release during stress.
Hashkavayi, Ayemeh Bagheri; Raoof, Jahan Bakhsh; Ojani, Reza; Kavoosian, Saeid
2017-06-15
Colorectal cancer is one of the most common cancers in the world and has no effective treatment. Therefore, development of new methods for early diagnosis is instantly required. Biological recognition probes such as synthetic receptor and aptamer is one of the candidate recognition layers to detect important biomolecules. In this work, an electrochemical aptasensor was developed by fabricating an aptamer-cell-aptamer sandwich architecture on an SBA-15-3-aminopropyltriethoxysilane (SBA-15-pr-NH 2 ) and Au nanoparticles (AuNPs) modified graphite screen printed electrode (GSPE) surface for the selective, label-free detection of CT26 cancer cells. Based on the incubation of the thiolated aptamer with CT26 cells, the electron-transfer resistance of Fe (CN) 6 3-/4- redox couple increased considerably on the aptasensor surface. The results obtained from cyclic voltammetry and electrochemical impedance spectroscopy studies showed that the fabricated aptasensor can specifically identify CT26 cells in the concentration ranges of 10-1.0×10 5 cells/mL and 1.0×10 5 -6.0×10 6 cells/mL, respectively, with a detection limit of 2cells/mL. Applying the thiol terminated aptamer (5TR1) as a recognition layer led to a sensor with high affinity for CT26 cancer cells, compared to control cancer cells of AGS cells, VERO Cells, PC3 cells and SKOV-3 cells. Therefore a simple, rapid, label free, inexpensive, excellent, sensitive and selective electrochemical aptasensor based on sandwich architecture was developed for detection of CT26 Cells. Copyright © 2016 Elsevier B.V. All rights reserved.
Cortés Romera, M; Gámez Cenzano, C; Caresia Aróztegui, A P; Martín-Comín, J; González-Barca, E; Ricart Brulles, Y; Palacios Abufón, A; Robles Barba, J; Rodríguez-Bel, L; Rossi Seoane, S; Fernández de Sevilla, A
2012-01-01
To assess the role of FDG-PET/CT performed after the first cycles of chemotherapy in the prediction of response to treatment in patients with diffuse large B-cell lymphoma. Twenty patients (mean age: 48 years) were included, 16 initial staging and 4 relapse. All patients underwent PET/CT at 3 times: 1) Baseline, 2) After 1-3 cycles of chemotherapy (early response assessment), and 3) End of treatment (evaluation of final response). Early PET/CT findings were correlated to the end-treatment PET/CT and follow-up. The evaluation of the response was established according to the decrease in uptake of the lesions (SUVmax). In the early assessment, a good response indicator (GRI) was obtained when the lesion disappeared or had more than 50% reduction in SUVmax. At the end of the treatment, a complete metabolic response (CMR) was determined in negative PET scans. Follow-up was superior to 19 months and final outcome was established as progression/relapse or no evidence of disease (NED). At the early treatment evaluation, 16/16 patients of initial staging (100%) and 2/4 of relapse (50%) achieved GRI. At the end of treatment evaluation, 14/16 patients of initial staging with GRI achieved CMR and 1/16 PMR: 14 were alive with NED in the follow-up while 1 relapsed. In the second group, 2/2 patients with GRI achieved CMR (100%): 1 continued with NED in the follow-up and another relapsed. FDG-PET/CT after the first cycles of chemotherapy is useful to monitor treatment due to its high negative predictive value (87.5%), using it to modify treatment early in the non-responders. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.
Salem, A; Salem, A F; Al-Ibraheem, A; Lataifeh, I; Almousa, A; Jaradat, I
2011-01-01
In recent years, the role of positron emission tomography (PET) in the staging and management of gynecological cancers has been increasing. The aim of this study was to systematically review the role of PET in radiotherapy planning and brachytherapy treatment optimization in patients with cervical cancer. Systematic literature review. Systematic review of relevant literature addressing the utilization of PET and/or PET-computed tomography (CT) in external-beam radiotherapy planning and brachytherapy treatment optimization. We performed an extensive PubMed database search on 20 April 2011. Nineteen studies, including 759 patients, formed the basis of this systematic review. PET/ PET-CT is the most sensitive imaging modality for detecting nodal metastases in patients with cervical cancer and has been shown to impact external-beam radiotherapy planning by modifying the treatment field and customizing the radiation dose. This particularly applies to detection of previously uncovered para-aortic and inguinal nodal metastases. Furthermore, PET/ PET-CT guided intensity-modulated radiation therapy (IMRT) allows delivery of higher doses of radiation to the primary tumor, if brachytherapy is unsuitable, and to grossly involved nodal disease while minimizing treatment-related toxicity. PET/ PET-CT based brachytherapy optimization allows improved tumor-volume dose distribution and detailed 3D dosimetric evaluation of risk organs. Sequential PET/ PET-CT imaging performed during the course of brachytherapy form the basis of âadaptiveâ brachytherapy in cervical cancer. This review demonstrates the effectiveness of pretreatment PET/ PET-CT in cervical cancer patients treated by radiotherapy. Further prospective studies are required to define the group of patients who would benefit the most from this procedure.
Chai, Orit; Peery, Dana; Bdolah-Abram, Tali; Moscovich, Efrat; Kelmer, Efrat; Klainbart, Sigal; Milgram, Joshua; Shamir, Merav H
2017-09-01
OBJECTIVE To characterize CT findings and outcomes in dogs with head trauma and design a prognostic scale. ANIMALS 27 dogs admitted to the Koret School Veterinary Teaching Hospital within 72 hours after traumatic head injury that underwent CT imaging of the head. PROCEDURES Data were extracted from medical records regarding dog signalment, history, physical and neurologic examination findings, and modified Glasgow coma scale scores. All CT images were retrospectively evaluated by a radiologist unaware of dog status. Short-term (10 days after trauma) and long-term (≥ 6 months after trauma) outcomes were determined, and CT findings and other variables were analyzed for associations with outcome. A prognostic CT-based scale was developed on the basis of the results. RESULTS Cranial vault fractures, parenchymal abnormalities, or both were identified via CT in 24 of 27 (89%) dogs. Three (11%) dogs had only facial bone fractures. Intracranial hemorrhage was identified in 16 (59%) dogs, cranial vault fractures in 15 (56%), midline shift in 14 (52%), lateral ventricle asymmetry in 12 (44%), and hydrocephalus in 7 (26%). Hemorrhage and ventricular asymmetry were significantly and negatively associated with short- and long-term survival, respectively. The developed 7-point prognostic scale included points for hemorrhage, midline shift or lateral ventricle asymmetry, cranial vault fracture, and depressed fracture (1 point each) and infratentorial lesion (3 points). CONCLUSIONS AND CLINICAL RELEVANCE The findings reported here may assist in determining prognoses for other dogs with head trauma. The developed scale may be useful for outcome assessment of dogs with head trauma; however, it must be validated before clinical application.
Hanks, Joanna; Ayed, Iyeman; Kukreja, Neil; Rogers, Chris; Harris, Jessica; Gheorghiu, Alina; Liu, Chee Ling; Emery, Peter; Pufulete, Maria
2013-12-01
Decreased genomic and increased gene-specific DNA methylation predispose to colorectal cancer. Dietary folate intake and the methylenetetrahydrofolate reductase polymorphism (MTHFR 677C>T) may influence risk by modifying DNA methylation. We investigated the associations between MTHFR 677C>T genotype, folate status, and DNA methylation in the colon. We conducted a cross-sectional study of 336 men and women (age 19-92 y) in the United Kingdom without colorectal neoplasia. We obtained blood samples for measurement of serum and red blood cell folate, plasma homocysteine, and MTHFR 677C>T genotype and colonic tissue biopsies for measurement of colonic tissue folate and DNA methylation (genomic- and gene-specific, estrogen receptor 1, ESR1; myoblast determination protein 1, MYOD1; insulin-like growth factor II, IGF2; tumor suppressor candidate 33, N33; adenomatous polyposis coli, APC; mut-L homolog 1, MLH1; and O(6)-methylguanine-DNA methyltransferase, MGMT) by liquid chromatography/electrospray ionization mass spectrometry and pyrosequencing, respectively. Of the 336 subjects recruited, 185 (55%) carried the CC, 119 (35%) the CT, and 32 (10%) the TT alleles. No significant differences in systemic markers of folate status and colonic tissue folate between genotypes were found. The MTHFR TT genotype was not associated with genomic or gene-specific DNA methylation. Biomarkers of folate status were not associated with genomic DNA methylation. Relations between biomarkers of folate status and gene-specific methylation were inconsistent. However, low serum folate was associated with high MGMT methylation (P = 0.001). MTHFR 677C>T genotype and folate status were generally not associated with DNA methylation in the colon of a folate-replete population without neoplasia.
The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.
Vorona, G A; Zuccoli, G; Sutcavage, T; Clayton, B L; Ceschin, R C; Panigrahy, A
2013-01-01
Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Xiaodong, E-mail: wangxde@gmail.com; Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org; Jia Xiaoyu, E-mail: jiax@mskcc.org
2013-08-01
PurposeTo determine if the pattern of retained contrast on immediate postprocedure computed tomography (CT) after particle embolization of hepatic tumors predicts modified Response Evaluation Criteria in Solid Tumors (mRECIST) response.Materials and MethodsThis study was approved by the Institutional Review Board with a waiver of authorization. One hundred four liver tumors were embolized with spherical embolic agents (Embospheres, Bead Block, LC Bead) and polyvinyl alcohol. Noncontrast CT was performed immediately after embolization to assess contrast retention in the targeted tumors, and treatment response was assessed by mRECIST criteria on follow-up CT (average time 9.0 {+-} 7.7 weeks after embolization). Tumor contrastmore » retention (TCR) was determined based on change in Hounsfield units (HUs) of the index tumors between the preprocedure and immediate postprocedure scans; vascular contrast retention (VCR) was rated; and defects in contrast retention (DCR) were also documented. The morphology of residual enhancing tumor on follow-up CT was described as partial, circumferential, or total. Association between TCR variables and tumor response were assessed using multivariate logistic regression.ResultsOf 104 hepatic tumors, 51 (49 %) tumors had complete response (CR) by mRECIST criteria; 23 (22.1 %) had partial response (PR); 21 (20.2 %) had stable disease (SD); and 9 (8.7 %) had progressive disease (PD). By multivariate analysis, TCR, VCR, and tumor size are independent predictors of CR (p = 0.02, 0.05, and 0.005 respectively). In 75 tumors, DCR was found to be an independent predictor of failure to achieve complete response (p < 0.0001) by imaging criteria.ConclusionTCR, VCR, and DCR on immediate posttreatment CT are independent predictors of CR by mRECIST criteria.« less
Kudryashova, E V; Gladilin, A K; Vakurov, A V; Heitz, F; Levashov, A V; Mozhaev, V V
1997-07-20
Formation of noncovalent complexes between alpha-chymotrypsin (CT) and a polyelectrolyte, polybrene (PB), has been shown to produce two major effects on enzymatic reactions in binary mixtures of polar organic cosolvents with water. (i) At moderate concentrations of organic cosolvents (10% to 30% v/v), enzymatic activity of CT is higher than in aqueous solutions, and this activation effect is more significant for CT in complex with PB (5- to 7-fold) than for free enzyme (1.5- to 2.5-fold). (ii) The range of cosolvent concentrations that the enzyme tolerates without complete loss of catalytic activity is much broader. For enhancement of enzyme stability in the complex with the polycation, the number of negatively charged groups in the protein has been artificially increased by using chemical modification with pyromellitic and succinic anhydrides. Additional activation effect at moderate concentrations of ethanol and enhanced resistance of the enzyme toward inactivation at high concentrations of the organic solvent have been observed for the modified preparations of CT in the complex with PB as compared with an analogous complex of the native enzyme. Structural changes behind alterations in enzyme activity in water-ethanol mixtures have been studied by the method of circular dichroism (CD). Protein conformation of all CT preparations has not changed significantly up to 30% v/v of ethanol where activation effects in enzymatic catalysis were most pronounced. At higher concentrations of ethanol, structural changes in the protein have been observed for different forms of CT that were well correlated with a decrease in enzymatic activity. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 55: 267-277, 1997.
Percutaneous CT-Guided Biopsy of C3 Vertebral Body: Modified Approach for an Old Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pua, Uei, E-mail: druei@yahoo.com; Chan, Stephen Yung-Wei
2013-06-15
Percutaneous biopsy of upper cervical vertebrae is challenging due to the various critical structures in the location and often requires difficult trajectory such as transoral or paramaxillary approaches. The purpose of this manuscript is to illustrate the utility of head rotation in creating a potential space for direct percutaneous access to C3 vertebral body for safe biopsy.
Intra-abdominal drain fracture following pancreatic necrosectomy.
Campbell, W; Wallace, W; Gibson, E; McCallion, K
2011-06-01
We describe a rare case of iatrogenic fracture of an intra-abdominal tube drain (Portex Robinson drain, Smiths Medical, Kent, UK) in a 74-year-old man. The fracture occurred at the level of an additionally placed fenestration and was identified on CT scanning prior to retrieval at planned re-laparotomy. This case highlights the potential dangers of modifying pre-formed drains and recommends against this practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, Eric; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca; Gardi, Lori
Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration butmore » modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu, T; Kearney, V; Liu, H
Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT correspondingmore » curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.« less
Correction for human head motion in helical x-ray CT
NASA Astrophysics Data System (ADS)
Kim, J.-H.; Sun, T.; Alcheikh, A. R.; Kuncic, Z.; Nuyts, J.; Fulton, R.
2016-02-01
Correction for rigid object motion in helical CT can be achieved by reconstructing from a modified source-detector orbit, determined by the object motion during the scan. This ensures that all projections are consistent, but it does not guarantee that the projections are complete in the sense of being sufficient for exact reconstruction. We have previously shown with phantom measurements that motion-corrected helical CT scans can suffer from data-insufficiency, in particular for severe motions and at high pitch. To study whether such data-insufficiency artefacts could also affect the motion-corrected CT images of patients undergoing head CT scans, we used an optical motion tracking system to record the head movements of 10 healthy volunteers while they executed each of the 4 different types of motion (‘no’, slight, moderate and severe) for 60 s. From these data we simulated 354 motion-affected CT scans of a voxelized human head phantom and reconstructed them with and without motion correction. For each simulation, motion-corrected (MC) images were compared with the motion-free reference, by visual inspection and with quantitative similarity metrics. Motion correction improved similarity metrics in all simulations. Of the 270 simulations performed with moderate or less motion, only 2 resulted in visible residual artefacts in the MC images. The maximum range of motion in these simulations would encompass that encountered in the vast majority of clinical scans. With severe motion, residual artefacts were observed in about 60% of the simulations. We also evaluated a new method of mapping local data sufficiency based on the degree to which Tuy’s condition is locally satisfied, and observed that areas with high Tuy values corresponded to the locations of residual artefacts in the MC images. We conclude that our method can provide accurate and artefact-free MC images with most types of head motion likely to be encountered in CT imaging, provided that the motion can be accurately determined.
Calcitonin and Amylin Receptor Peptide Interaction Mechanisms
Lee, Sang-Min; Hay, Debbie L.; Pioszak, Augen A.
2016-01-01
Receptor activity-modifying proteins (RAMP1–3) determine the selectivity of the class B G protein-coupled calcitonin receptor (CTR) and the CTR-like receptor (CLR) for calcitonin (CT), amylin (Amy), calcitonin gene-related peptide (CGRP), and adrenomedullin (AM) peptides. RAMP1/2 alter CLR selectivity for CGRP/AM in part by RAMP1 Trp-84 or RAMP2 Glu-101 contacting the distinct CGRP/AM C-terminal residues. It is unclear whether RAMPs use a similar mechanism to modulate CTR affinity for CT and Amy, analogs of which are therapeutics for bone disorders and diabetes, respectively. Here, we reproduced the peptide selectivity of intact CTR, AMY1 (CTR·RAMP1), and AMY2 (CTR·RAMP2) receptors using purified CTR extracellular domain (ECD) and tethered RAMP1- and RAMP2-CTR ECD fusion proteins and antagonist peptides. All three proteins bound salmon calcitonin (sCT). Tethering RAMPs to CTR enhanced binding of rAmy, CGRP, and the AMY antagonist AC413. Peptide alanine-scanning mutagenesis and modeling of receptor-bound sCT and AC413 supported a shared non-helical CGRP-like conformation for their TN(T/V)G motif prior to the C terminus. After this motif, the peptides diverged; the sCT C-terminal Pro was crucial for receptor binding, whereas the AC413/rAmy C-terminal Tyr had little or no influence on binding. Accordingly, mutant RAMP1 W84A- and RAMP2 E101A-CTR ECD retained AC413/rAmy binding. ECD binding and cell-based signaling assays with antagonist sCT/AC413/rAmy variants with C-terminal residue swaps indicated that the C-terminal sCT/rAmy residue identity affects affinity more than selectivity. rAmy(8–37) Y37P exhibited enhanced antagonism of AMY1 while retaining selectivity. These results reveal unexpected differences in how RAMPs determine CTR and CLR peptide selectivity and support the hypothesis that RAMPs allosterically modulate CTR peptide affinity. PMID:26895962
Craciunescu, Corneliu N; Johnson, Amy R; Zeisel, Steven H
2010-06-01
In mice, maternal dietary folate, a cofactor in 1-carbon metabolism, modulates neurogenesis and apoptosis in the fetal brain. Similarly, maternal dietary choline, an important methyl-donor, also influences these processes. Choline and folate are metabolically interrelated, and we determined whether choline supplementation could reverse the effects of folate deficiency on brain development. Timed-pregnant mice were fed control (CT), folate-deficient (FD), or folate-deficient, choline-supplemented (FDCS) AIN-76 diets from d 11 to 17 (E11-17) of pregnancy, and on E17, fetal brains were collected for analysis. Compared with the CT group, the FD group had fewer neural progenitor cells undergoing mitosis in the ventricular zones of the developing mouse brain septum (47%; P < 0.01), hippocampus (29%; P < 0.01), striatum (34%; P < 0.01), and anterior and mid-posterior neocortex (33% in both areas; P < 0.01). In addition, compared with CT, the FD diet almost doubled the rate of apoptosis in the fetal septum and hippocampus (P < 0.01). In the FDCS group, the mitosis rates generally were intermediate between those of the CT and FD groups; mitosis rates in the septum and striatum were significantly greater compared with the FD group and were significantly lower than in the CT group only in the septum and neocortex. In the FDCS group, the hippocampal apoptosis rate was significantly lower than in the FD group (P < 0.01) and was the same as in the CT group. In the septum, the apotosis rate in the FDCS group was intermediate between the CT and FD groups' rates. These results suggest that neural progenitor cells in fetal forebrain are sensitive to maternal dietary folate during late gestation and that choline supplementation can modify some, but not all, of these effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, S; Markel, D; Hegyi, G
2016-06-15
Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with amore » grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image acquisition parameters.« less
Kirsch, Jacobo; Martinez, Felipe; Lopez, David; Novaro, Gian M; Asher, Craig R
2017-02-01
Coronary artery calcification (CAC) is a known risk factor for adverse outcomes in the general population and in patients with coronary artery disease. We performed a survey of United States radiologists to evaluate the trends in reporting the presence or absence of CAC on NCCT examinations. An 11 multiple-choice questionnaire was distributed to members of the American College of Radiology, and 530 members participated in the study. Eighty-seven percent of the analyzed group report the presence of CAC on standard CT scans of the chest, and approximately half them (52 %) use a qualitative modifier. Only 32 % of cardiac imagers were aware of the published data correlating qualitative and quantitative calcium scores on non-gated chest CT examinations compared to 17 % of non-cardiac imagers. We believe that subjective or objective grading of coronary calcified plaque burden on standard chest CT exams is warranted as it may not only help risk-stratify patients, but also may eliminate the need for dedicated CACS in many patients and may be useful in treatment guidance.
Diagnostic value of imaging in infective endocarditis: a systematic review.
Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu
2017-01-01
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Range prediction for tissue mixtures based on dual-energy CT
NASA Astrophysics Data System (ADS)
Möhler, Christian; Wohlfahrt, Patrick; Richter, Christian; Greilich, Steffen
2016-06-01
The use of dual-energy CT (DECT) potentially decreases range uncertainties in proton and ion therapy treatment planning via determination of the involved physical target quantities. For eventual clinical application, the correct treatment of tissue mixtures and heterogeneities is an essential feature, as they naturally occur within a patient’s CT. Here, we present how existing methods for DECT-based ion-range prediction can be modified in order to incorporate proper mixing behavior on several structural levels. Our approach is based on the factorization of the stopping-power ratio into the relative electron density and the relative stopping number. The latter is confined for tissue between about 0.95 and 1.02 at a therapeutic beam energy of 200 MeV u-1 and depends on the I-value. We show that convenient mixing and averaging properties arise by relating the relative stopping number to the relative cross section obtained by DECT. From this, a maximum uncertainty of the stopping-power ratio prediction below 1% is suggested for arbitrary mixtures of human body tissues.
Vélez-Fort, Mateo; Rousseau, Charly V; Niedworok, Christian J; Wickersham, Ian R; Rancz, Ede A; Brown, Alexander P Y; Strom, Molly; Margrie, Troy W
2014-09-17
Sensory computations performed in the neocortex involve layer six (L6) cortico-cortical (CC) and cortico-thalamic (CT) signaling pathways. Developing an understanding of the physiological role of these circuits requires dissection of the functional specificity and connectivity of the underlying individual projection neurons. By combining whole-cell recording from identified L6 principal cells in the mouse primary visual cortex (V1) with modified rabies virus-based input mapping, we have determined the sensory response properties and upstream monosynaptic connectivity of cells mediating the CC or CT pathway. We show that CC-projecting cells encompass a broad spectrum of selectivity to stimulus orientation and are predominantly innervated by deep layer V1 neurons. In contrast, CT-projecting cells are ultrasparse firing, exquisitely tuned to orientation and direction information, and receive long-range input from higher cortical areas. This segregation in function and connectivity indicates that L6 microcircuits route specific contextual and stimulus-related information within and outside the cortical network. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Grams, Astrid Ellen; Djurdjevic, Tanja; Rehwald, Rafael; Schiestl, Thomas; Dazinger, Florian; Steiger, Ruth; Knoflach, Michael; Gizewski, Elke Ruth; Glodny, Bernhard
2018-05-04
The aim was to investigate whether dual-energy computed tomography (DECT) reconstructions optimised for oedema visualisation (oedema map; EM) facilitate an improved detection of early infarctions after endovascular stroke therapy (EST). Forty-six patients (21 women; 25 men; mean age: 63 years; range 24-89 years) were included. The brain window (BW), virtual non-contrast (VNC) and modified VNC series based on a three-material decomposition technique optimised for oedema visualisation (EM) were evaluated. Follow-up imaging was used as the standard for comparison. Contralateral side to infarction differences in density (CIDs) were determined. Infarction detectability was assessed by two blinded readers, as well as image noise and contrast using Likert scales. ROC analyses were performed and the respective Youden indices calculated for cut-off analysis. The highest CIDs were found in the EM series (73.3 ± 49.3 HU), compared with the BW (-1.72 ± 13.29 HU) and the VNC (8.30 ± 4.74 HU) series. The EM was found to have the highest infarction detection rates (area under the curve: 0.97 vs. 0.54 and 0.90, p < 0.01) with a cut-off value of < 50.7 HU, despite slightly more pronounced image noise. The location of the infarction did not affect detectability (p > 0.05 each). The EM series allows higher contrast and better early infarction detection than the VNC or BW series after EST. • Dual-energy CT EM allows better early infarction detection than standard brain window. • Dual-energy CT EM series allow better early infarction detection than VNC series. • Dual-energy CT EM are modified VNC based on water content of tissue.
Ferreira, António Miguel; Marques, Hugo; Tralhão, António; Santos, Miguel Borges; Santos, Ana Rita; Cardoso, Gonçalo; Dores, Hélder; Carvalho, Maria Salomé; Madeira, Sérgio; Machado, Francisco Pereira; Cardim, Nuno; de Araújo Gonçalves, Pedro
2016-11-01
Current guidelines recommend the use of the Modified Diamond-Forrester (MDF) method to assess the pre-test likelihood of obstructive coronary artery disease (CAD). We aimed to compare the performance of the MDF method with two contemporary algorithms derived from multicenter trials that additionally incorporate cardiovascular risk factors: the calculator-based 'CAD Consortium 2' method, and the integer-based CONFIRM score. We assessed 1069 consecutive patients without known CAD undergoing coronary CT angiography (CCTA) for stable chest pain. Obstructive CAD was defined as the presence of coronary stenosis ≥50% on 64-slice dual-source CT. The three methods were assessed for calibration, discrimination, net reclassification, and changes in proposed downstream testing based upon calculated pre-test likelihoods. The observed prevalence of obstructive CAD was 13.8% (n=147). Overestimations of the likelihood of obstructive CAD were 140.1%, 9.8%, and 18.8%, respectively, for the MDF, CAD Consortium 2 and CONFIRM methods. The CAD Consortium 2 showed greater discriminative power than the MDF method, with a C-statistic of 0.73 vs. 0.70 (p<0.001), while the CONFIRM score did not (C-statistic 0.71, p=0.492). Reclassification of pre-test likelihood using the 'CAD Consortium 2' or CONFIRM scores resulted in a net reclassification improvement of 0.19 and 0.18, respectively, which would change the diagnostic strategy in approximately half of the patients. Newer risk factor-encompassing models allow for a more precise estimation of pre-test probabilities of obstructive CAD than the guideline-recommended MDF method. Adoption of these scores may improve disease prediction and change the diagnostic pathway in a significant proportion of patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
González, R Gilberto; Furie, Karen L; Goldmacher, Gregory V; Smith, Wade S; Kamalian, Shervin; Payabvash, Seyedmehdi; Harris, Gordon J; Halpern, Elkan F; Koroshetz, Walter J; Camargo, Erica C S; Dillon, William P; Lev, Michael H
2013-11-01
To determine the effect of intravenous tissue plasminogen activator (IV-tPA) on outcomes in patients with severe major anterior circulation ischemic stroke. Prospectively, 649 patients with acute stroke had admission National Institutes of Health stroke scale (NIHSS) scores, noncontrast computed tomography (CT), CT angiography (CTA), and 6-month outcome assessed using modified Rankin scale. IV-tPA treatment decisions were made before CTA, at the time of noncontrast CT scanning, as per routine clinical protocol. Severe symptoms were defined as NIHSS>10. Poor outcome was defined as modified Rankin scale >2. Major occlusions were identified on CTA. Univariate and multivariate stepwise-forward logistic regression analyses of the full cohort were performed. Of 649 patients, 188 (29%) patients presented with NIHSS>10, and 64 out of 188 (34%) patients received IV-tPA. Admission NIHSS, large artery occlusion, and IV-tPA all independently predicted good outcomes; however, a significant interaction existed between IV-tPA and occlusion (P<0.001). Of the patients who presented with NIHSS>10 with anterior circulation occlusion, twice the percentage had good outcomes if they received IV-tPA (17 out of 49 patients, 35%) than if they did not (13 out of 77 patients, 17%; P=0.031). The number needed to treat was 7 (95% confidence interval, 3-60). IV-tPA treatment resulted in significantly better outcomes in patients with severely symptomatic stroke with major anterior circulation occlusions. The 35% good outcome rate was similar to rates found in endovascular therapy trials. Vascular imaging may help in patient selection and stratification for trials of IV-thrombolytic and endovascular therapies.
Walz, Paul H; Newcomer, Benjamin W; Riddell, Kay P; Scruggs, Daniel W; Cortese, Victor S
2017-09-01
We evaluated duration of PCR-positive results following administration of modified-live viral (MLV) vaccines to beef calves. Twenty beef calves were randomly assigned to either group 1 and vaccinated intranasally with a MLV vaccine containing bovine alphaherpesvirus 1 (BoHV-1), bovine respiratory syncytial virus (BRSV), and bovine parainfluenza virus 3 (BPIV-3), or to group 2 and vaccinated subcutaneously with a MLV vaccine containing bovine viral diarrhea virus 1 and 2 (BVDV-1, -2), BoHV-1, BRSV, and BPIV-3. Deep nasopharyngeal swabs (NPS) and transtracheal washes (TTW) were collected from all calves, and whole blood was collected from group 2 calves and tested by PCR. In group 1, the proportions of calves that tested PCR-positive to BVDV, BoHV-1, BRSV, and BPIV-3 on any sample at any time were 0%, 100%, 100%, and 10%, respectively. In group 1 calves, 100% of calves became PCR-positive for BoHV-1 by day 3 post-vaccination and 100% of calves became PCR-positive for BRSV by day 7 post-vaccination. In group 2, the proportions of calves that tested positive to BVDV, BoHV-1, BRSV, and BPIV-3 on any sample at any time were 50%, 40%, 10%, and 0%, respectively. All threshold cycle (Ct) values were >30 in group 2 calves, irrespective of virus; however, Ct values <25 were observed in group 1 calves from PCR-positive results for BoHV-1 and BRSV. All calves were PCR-negative for all viruses after day 28. Following intranasal MLV viral vaccination, PCR results and Ct values for BRSV and BoHV-1 suggest that attempts to differentiate vaccine virus from natural infection is unreliable.
Azizian, Mohammad F; Semprini, Lewis
2017-08-01
The simultaneous anaerobic transformation of tetrachloroethene (PCE) and carbon tetrachloride (CT) was evaluated in a continuous flow column. The column was packed with quartz sand and bioaugmented with the Evanite culture (EV) that is capable of transforming PCE to ethene. Azizian and Semprini (2016) reported that PCE and CT could be simultaneously transformed in the column, with PCE (0.1mM) transformed mainly to ethene and CT (0.015mM) to chloroform (CF) (20%) and an unknown transformation product, likely carbon dioxide (CO 2 ). The fermentation of propionate, formed from lactate fermentation, was inhibited after the transformation of CT, likely from the exposure to CF. Reported here is the second phase of that study where a second bioaugmentation of the EV culture was made to reintroduce a lactate and propionate fermenting population to the column. Effective lactate and propionate fermentation were restored with a H 2 concentration of ~25nM maintained in the column effluent. PCE (0.1mM) was effectively transformed to ethene (~98%) and vinyl chloride (VC) (~2%). Unlabeled CT (0.015 to 0.03mM) was completely transformed with a transient build-up of CF and chloromethane (CM), which were subsequently removed below their detection limits. A series of transient tests were initiated through the addition of carbon-13 labeled CT ( 13 CT), with concentrations gradually increased from 0.03 to 0.10mM. GC-MS analysis of the column effluent showed that 13 C labeled CO 2 ( 13 CO 2 ) was formed, ranging from 82 to 93% of the 13 CT transformed, with the transient increases in 13 CO 2 associated with the increased concentration of 13 CT. A modified COD analysis indicated a lesser amount of 13 CT (18%) was transformed to soluble products, while 13 CO 2 represented 82% the 13 CT transformed. In a final transient test, the influent lactate concentration was decreased from 1.1 to 0.67mM. The transformation of both CT and PCE changed dramatically. Only 59% of the 13 CT was transformed, primarily to CF. 13 CO 2 concentrations gradually decreased to background levels, indicating CO 2 was no longer a transformation product. PCE transformation resulted in the following percentage of products formed: cDCE (60%), VC (36%), and ethene (4%). Incomplete propionate fermentation was also observed, consistent with the build-up of CF and the decrease in H 2 concentrations to approximately 2nM. The results clearly demonstrate that high concentrations of CT were transformed to CO 2 , and effective PCE dehalogenation to ethene was maintained when excess lactate was fed and propionate was effectively fermented. However, when the lactate concentration was reduced, both PCE and CT transformation and propionate fermentation were negatively impacted. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Azizian, Mohammad F.; Semprini, Lewis
2017-08-01
The simultaneous anaerobic transformation of tetrachloroethene (PCE) and carbon tetrachloride (CT) was evaluated in a continuous flow column. The column was packed with quartz sand and bioaugmented with the Evanite culture (EV) that is capable of transforming PCE to ethene. Azizian and Semprini (2016) reported that PCE and CT could be simultaneously transformed in the column, with PCE (0.1 mM) transformed mainly to ethene and CT (0.015 mM) to chloroform (CF) (20%) and an unknown transformation product, likely carbon dioxide (CO2). The fermentation of propionate, formed from lactate fermentation, was inhibited after the transformation of CT, likely from the exposure to CF. Reported here is the second phase of that study where a second bioaugmentation of the EV culture was made to reintroduce a lactate and propionate fermenting population to the column. Effective lactate and propionate fermentation were restored with a H2 concentration of 25 nM maintained in the column effluent. PCE (0.1 mM) was effectively transformed to ethene ( 98%) and vinyl chloride (VC) ( 2%). Unlabeled CT (0.015 to 0.03 mM) was completely transformed with a transient build-up of CF and chloromethane (CM), which were subsequently removed below their detection limits. A series of transient tests were initiated through the addition of carbon-13 labeled CT (13CT), with concentrations gradually increased from 0.03 to 0.10 mM. GC-MS analysis of the column effluent showed that 13C labeled CO2 (13CO2) was formed, ranging from 82 to 93% of the 13CT transformed, with the transient increases in 13CO2 associated with the increased concentration of 13CT. A modified COD analysis indicated a lesser amount of 13CT (18%) was transformed to soluble products, while 13CO2 represented 82% the 13CT transformed. In a final transient test, the influent lactate concentration was decreased from 1.1 to 0.67 mM. The transformation of both CT and PCE changed dramatically. Only 59% of the 13CT was transformed, primarily to CF. 13CO2 concentrations gradually decreased to background levels, indicating CO2 was no longer a transformation product. PCE transformation resulted in the following percentage of products formed: cDCE (60%), VC (36%), and ethene (4%). Incomplete propionate fermentation was also observed, consistent with the build-up of CF and the decrease in H2 concentrations to approximately 2 nM. The results clearly demonstrate that high concentrations of CT were transformed to CO2, and effective PCE dehalogenation to ethene was maintained when excess lactate was fed and propionate was effectively fermented. However, when the lactate concentration was reduced, both PCE and CT transformation and propionate fermentation were negatively impacted.
Pripatnanont, P; Balabid, F; Pongpanich, S; Vongvatcharanon, S
2015-05-01
This study evaluated the effect of a modified Hyrax device and platelet-rich fibrin (PRF) on osteogenic periosteal distraction (OPD). Twelve adult male New Zealand white rabbits were separated into two main groups (six in each) according to the duration of the consolidation period (4 or 8 weeks). In each main group, the animals underwent OPD of the left and right sides of the mandible and were divided into four subgroups (three animals per group): device vs. device+PRF, and PRF vs. sham. Radiographic, histological, histomorphometric, and micro-computed tomography (micro-CT) analyses were performed. New bone formation was observed on the lateral and vertical sides of the mandible of all groups. Micro-CT and histomorphometry showed that the device+PRF group presented the highest percentages of bone volume and bone area at 4 weeks (56.67 ± 12.67%, 41.37 ± 7.57%) and at 8 weeks (49.67 ± 8.33%, 55.46 ± 10.67%; significantly higher than the other groups, P<0.001), followed by the device group at 4 weeks (33.00 ± 1.73%, 33.21 ± 11.00%) and at 8 weeks (30.00 ± 3.00%, 23.25 ± 5.46%). In conclusion, the modified Hyrax device was used successfully for OPD in a rabbit model to gain vertical ridge augmentation, and greater bone maturation was achieved with the addition of PRF. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics
NASA Astrophysics Data System (ADS)
King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.
2011-03-01
The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.
CT-scout based, semi-automated vertebral morphometry after digital image enhancement.
Glinkowski, Wojciech M; Narloch, Jerzy
2017-09-01
Radiographic diagnosis of osteoporotic vertebral fracture is necessary to reduce its substantial associated morbidity. Computed tomography (CT) scout has recently been demonstrated as a reliable technique for vertebral fracture diagnosis. Software assistance may help to overcome some limitations of that diagnostics. We aimed to evaluate whether digital image enhancement improved the capacity of one of the existing software to detect fractures semi-automatically. CT scanograms of patients suffering from osteoporosis, with or without vertebral fractures were analyzed. The original set of CT scanograms were triplicated and digitally modified to improve edge detection using three different techniques: SHARPENING, UNSHARP MASKING, and CONVOLUTION. The manual morphometric analysis identified 1485 vertebrae, 200 of which were classified as fractured. Unadjusted morphometry (AUTOMATED with no digital enhancement) found 63 fractures, 33 of which were true positive (i.e., it correctly identified 52% of the fractures); SHARPENING detected 57 fractures (30 true positives, 53%); UNSHARP MASKING yielded 30 (13 true positives, 43%); and CONVOLUTION found 24 fractures (9 true positives, 38%). The intra-reader reliability for height ratios did not significantly improve with image enhancement (kappa ranged 0.22-0.41 for adjusted measurements and 0.16-0.38 for unadjusted). Similarly, the inter-reader agreement for prevalent fractures did not significantly improve with image enhancement (kappa 0.29-0.56 and -0.01 to 0.23 for adjusted and unadjusted measurements, respectively). Our results suggest that digital image enhancement does not improve software-assisted vertebral fracture detection by CT scout. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hashim, S.; Karim, M. K. A.; Bakar, K. A.; Sabarudin, A.; Chin, A. W.; Saripan, M. I.; Bradley, D. A.
2016-09-01
The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, 8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose.
A general ansatz for constructing quasi-diabatic states in electronically excited aggregated systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Wenlan; Köhn, Andreas; InnovationLab GmbH, Speyerer St. 4, D-69115 Heidelberg
2015-08-28
We present a general method for analyzing the character of singly excited states in terms of charge transfer (CT) and locally excited (LE) configurations. The analysis is formulated for configuration interaction singles (CIS) singly excited wave functions of aggregate systems. It also approximately works for the second-order approximate coupled cluster singles and doubles and the second-order algebraic-diagrammatic construction methods [CC2 and ADC(2)]. The analysis method not only generates a weight of each character for an excited state, but also allows to define the related quasi-diabatic states and corresponding coupling matrix elements. In the character analysis approach, we divide the targetmore » system into domains and use a modified Pipek-Mezey algorithm to localize the canonical MOs on each domain, respectively. The CIS wavefunction is then transformed into the localized basis, which allows us to partition the wavefunction into LE configurations within domains and CT configuration between pairs of different domains. Quasi-diabatic states are then obtained by mixing excited states subject to the condition of maximizing the weight of one single LE or CT configuration (localization in configuration space). Different aims of such a procedure are discussed, either the construction of pure LE and CT states for analysis purposes (by including a large number of excited states) or the construction of effective models for dynamics calculations (by including a restricted number of excited states). Applications are given to LE/CT mixing in π-stacked systems, charge-recombination matrix elements in a hetero-dimer, and excitonic couplings in multi-chromophoric systems.« less
SU-E-I-43: Pediatric CT Dose and Image Quality Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, G; Singh, R
2014-06-01
Purpose: To design an approach to optimize radiation dose and image quality for pediatric CT imaging, and to evaluate expected performance. Methods: A methodology was designed to quantify relative image quality as a function of CT image acquisition parameters. Image contrast and image noise were used to indicate expected conspicuity of objects, and a wide-cone system was used to minimize scan time for motion avoidance. A decision framework was designed to select acquisition parameters as a weighted combination of image quality and dose. Phantom tests were used to acquire images at multiple techniques to demonstrate expected contrast, noise and dose.more » Anthropomorphic phantoms with contrast inserts were imaged on a 160mm CT system with tube voltage capabilities as low as 70kVp. Previously acquired clinical images were used in conjunction with simulation tools to emulate images at different tube voltages and currents to assess human observer preferences. Results: Examination of image contrast, noise, dose and tube/generator capabilities indicates a clinical task and object-size dependent optimization. Phantom experiments confirm that system modeling can be used to achieve the desired image quality and noise performance. Observer studies indicate that clinical utilization of this optimization requires a modified approach to achieve the desired performance. Conclusion: This work indicates the potential to optimize radiation dose and image quality for pediatric CT imaging. In addition, the methodology can be used in an automated parameter selection feature that can suggest techniques given a limited number of user inputs. G Stevens and R Singh are employees of GE Healthcare.« less
DOE R&D Accomplishments Database
Freifeld, Barry M.; Kneafsey, Timothy J.; Tomutsa, Liviu; Stern, Laura A.; Kirby, Stephen H.
2002-02-28
X-ray computed tomography (CT) is a method that has been used extensively in laboratory experiments for measuring rock properties and fluid transport behavior. More recently, CT scanning has been applied successfully to detect the presence and study the behavior of naturally occurring hydrates. In this study, we used a modified medical CT scanner to image and analyze the progression of a dissociation front in a synthetic methane hydrate/sand mixture. The sample was initially scanned under conditions at which the hydrate is stable (atmospheric pressure and liquid nitrogen temperature, 77 K). The end of the sample holder was then exposed to the ambient air, and the core was continuously scanned as dissociation occurred in response to the rising temperature. CT imaging captured the advancing dissociation front clearly and accurately. The evolved gas volume was monitored as a function of time. Measured by CT, the advancing hydrate dissociation front was modeled as a thermal conduction problem explicitly incorporating the enthalpy of dissociation, using the Stefan moving-boundary-value approach. The assumptions needed to perform the analysis consisted of temperatures at the model boundaries. The estimated value for thermal conductivity of 2.6 W/m K for the remaining water ice/sand mixture is higher than expected based on conduction alone; this high value may represent a lumped parameter that incorporates the processes of heat conduction, methane gas convection, and any kinetic effects that occur during dissociation. The technique presented here has broad implications for future laboratory and field testing that incorporates geophysical techniques to monitor gas hydrate dissociation.
Moving Beam-Blocker-Based Low-Dose Cone-Beam CT
NASA Astrophysics Data System (ADS)
Lee, Taewon; Lee, Changwoo; Baek, Jongduk; Cho, Seungryong
2016-10-01
This paper experimentally demonstrates a feasibility of moving beam-blocker-based low-dose cone-beam CT (CBCT) and exploits the beam-blocking configurations to reach an optimal one that leads to the highest contrast-to-noise ratio (CNR). Sparse-view CT takes projections at sparse view angles and provides a viable option to reducing dose. We have earlier proposed a many-view under-sampling (MVUS) technique as an alternative to sparse-view CT. Instead of switching the x-ray tube power, one can place a reciprocating multi-slit beam-blocker between the x-ray tube and the patient to partially block the x-ray beam. We used a bench-top circular cone-beam CT system with a lab-made moving beam-blocker. For image reconstruction, we used a modified total-variation minimization (TV) algorithm that masks the blocked data in the back-projection step leaving only the measured data through the slits to be used in the computation. The number of slits and the reciprocation frequency have been varied and the effects of them on the image quality were investigated. For image quality assessment, we used CNR and the detectability. We also analyzed the sampling efficiency in the context of compressive sensing: the sampling density and data incoherence in each case. We tested three sets of slits with their number of 6, 12 and 18, each at reciprocation frequencies of 10, 30, 50 and 70 Hz/rot. The optimum condition out of the tested sets was found to be using 12 slits at 30 Hz/rot.
GPU-accelerated regularized iterative reconstruction for few-view cone beam CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matenine, Dmitri, E-mail: dmitri.matenine.1@ulaval.ca; Goussard, Yves, E-mail: yves.goussard@polymtl.ca; Després, Philippe, E-mail: philippe.despres@phy.ulaval.ca
2015-04-15
Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it ismore » implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Y; Liao, Z; Jiang, W
Purpose: To evaluate the feasibility of using an automatic segmentation tool to delineate cardiac substructures from computed tomography (CT) images for cardiac toxicity analysis for non-small cell lung cancer (NSCLC) patients after radiotherapy. Methods: A multi-atlas segmentation tool developed in-house was used to delineate eleven cardiac substructures including the whole heart, four heart chambers, and six greater vessels automatically from the averaged 4DCT planning images for 49 NSCLC patients. The automatic segmented contours were edited appropriately by two experienced radiation oncologists. The modified contours were compared with the auto-segmented contours using Dice similarity coefficient (DSC) and mean surface distance (MSD)more » to evaluate how much modification was needed. In addition, the dose volume histogram (DVH) of the modified contours were compared with that of the auto-segmented contours to evaluate the dosimetric difference between modified and auto-segmented contours. Results: Of the eleven structures, the averaged DSC values ranged from 0.73 ± 0.08 to 0.95 ± 0.04 and the averaged MSD values ranged from 1.3 ± 0.6 mm to 2.9 ± 5.1mm for the 49 patients. Overall, the modification is small. The pulmonary vein (PV) and the inferior vena cava required the most modifications. The V30 (volume receiving 30 Gy or above) for the whole heart and the mean dose to the whole heart and four heart chambers did not show statistically significant difference between modified and auto-segmented contours. The maximum dose to the greater vessels did not show statistically significant difference except for the PV. Conclusion: The automatic segmentation of the cardiac substructures did not require substantial modification. The dosimetric evaluation showed no statistically significant difference between auto-segmented and modified contours except for the PV, which suggests that auto-segmented contours for the cardiac dose response study are feasible in the clinical practice with a minor modification to the PV vessel.« less
Kobayashi, Adam; Wardlaw, Joanna M; Lindley, Richard I; Lewis, Steff C; Sandercock, Peter A G; Czlonkowska, Anna
2009-03-01
The Oxfordshire Community Stroke Project (OCSP) clinical stroke syndrome classification correlates well with the stroke lesion in established ischemic stroke, but there are few data in patients with hyperacute stroke. We wished to assess whether the OCSP correlated with the site and size of the ischemic lesion and location of cerebral vessel lesion on computed tomography (CT) in hyperacute stroke. Prospective study of ischemic stroke patients presenting within 6 hours of onset in the Third International Stroke Trial (IST-3), a randomized, controlled trial of rt-PA. OCSP syndrome was assigned by a computer-based algorithm. The CT assessment was made by a neuroradiologist blinded to clinical details. We assessed baseline data and CT findings for the first 510 patients; early tissue ischemic changes were present in 329/510 (65%) total anterior circulation syndrome (TACS) - 79%; partial anterior circulation syndrome (PACS) - 57%, lacunar syndrome (LACS) - 40%; posterior circulation syndrome (POCS) - 33%. The site and size of ischemic change on CT was compatible with the clinical syndrome in 79%, 37%, 2%, and 14%, respectively. Assuming that all patients with a normal CT scan will develop an incompatible lesion these numbers reflected the "worst possible scenario." For the "best possible scenario" we presumed that those with a normal CT will develop concordant ischemic change and the proportions were 100%, 80%, 62% and 81%, respectively. The hyperattenuated artery sign was seen in 206/510 (40%); (TACS 54%; PACS 35%, LACS 5%, and POCS 19%). Within 6 hours of stroke, in patients with a nonlacunar syndrome, the OCSP syndrome correlated well with the pattern of ischemic change on CT. For clinicians who wish to restrict the use of thrombolytic therapy to large-artery ischemic stroke, concordance of clinical and CT appearances may give greater confidence in making therapeutic decisions in hyperacute stroke. In centers where immediate access to MR is limited, use of the classification may help focus use of MR on patients with suspected LACS and POCS. The utility of the classification may further increase if IST-3 establishes that the OCSP syndrome significantly modifies response to thrombolytic therapy.
Liang, Ming-Tai; Chen, Clayton Chi-Chang; Wang, Ching-Ping; Wang, Chen-Chi; Lin, Whe-Dar; Liu, Shih-An
2009-06-01
The aim of this study was to determine if volume of cervical lymph node measured via computed tomography (CT) could differentiate metastatic from benign lesions in head and neck cancer patients. We conducted a retrospective review of chart and images in a tertiary referring center in Taiwan. Patients with head and neck cancers underwent radical, modified radical or functional neck dissection were enrolled. The CT images before operation were reassessed by a radiologist and were compared with the results of pathological examination. A total of 102 patients were included for final analyses. Most patients were male (n = 96, 94%) and average age was 50.1 years. Although the average nodal volume in patients with cervical metastases was higher than those of patients without cervical metastases, it was not an independent factor associated with cervical metastasis after controlling for other variables; however, central nodal necrosis on enhanced CT image [odds ratio (OR) 18.95, P = 0.008) and minimal axial diameter >7.5 mm (OR 6.868, P = 0.001) were independent factors correlated with cervical metastasis. Therefore, the volume of cervical lymph node measured from CT images cannot predict cervical metastases in head and neck cancer patients. Measurement of minimal axial diameter of the largest lymph node is a simple and more accurate way to predict cervical metastasis instead.
Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.
Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J
2006-01-01
Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.
Multiple supervised residual network for osteosarcoma segmentation in CT images.
Zhang, Rui; Huang, Lin; Xia, Wei; Zhang, Bo; Qiu, Bensheng; Gao, Xin
2018-01-01
Automatic and accurate segmentation of osteosarcoma region in CT images can help doctor make a reasonable treatment plan, thus improving cure rate. In this paper, a multiple supervised residual network (MSRN) was proposed for osteosarcoma image segmentation. Three supervised side output modules were added to the residual network. The shallow side output module could extract image shape features, such as edge features and texture features. The deep side output module could extract semantic features. The side output module could compute the loss value between output probability map and ground truth and back-propagate the loss information. Then, the parameters of residual network could be modified by gradient descent method. This could guide the multi-scale feature learning of the network. The final segmentation results were obtained by fusing the results output by the three side output modules. A total of 1900 CT images from 15 osteosarcoma patients were used to train the network and a total of 405 CT images from another 8 osteosarcoma patients were used to test the network. Results indicated that MSRN enabled a dice similarity coefficient (DSC) of 89.22%, a sensitivity of 88.74% and a F1-measure of 0.9305, which were larger than those obtained by fully convolutional network (FCN) and U-net. Thus, MSRN for osteosarcoma segmentation could give more accurate results than FCN and U-Net. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bronchiectasis: correlation of high-resolution CT findings with health-related quality of life.
Eshed, I; Minski, I; Katz, R; Jones, P W; Priel, I E
2007-02-01
To evaluate the relationship between the severity of bronchiectatic diseases, as evident on high-resolution computed tomography (HRCT) and the patient's quality of life measured using the St George's Respiratory Questionnaire (SGRQ). Forty-six patients (25 women, 21 men, mean age: 63 years) with bronchiectatic disease as evident on recent HRCT examinations were recruited. Each patient completed the SGRQ and underwent respiratory function tests. HRCT findings were blindly and independently scored by two radiologists, using the modified Bhalla scoring system. The relationships between HRCT scores, SGRQ scores and pulmonary function tests were evaluated. The patients' total CT score did not correlate with the SGRQ scores. However, patients with more advanced disease on HRCT, significantly differed in their SGRQ scores from patients with milder bronchiectatic disease. A significant correlation was found between the CT scores for the middle and distal lung zones and the activity, impacts and total SGRQ scores. No correlation was found between CT scores and respiratory function test indices. However, a significant correlation was found between the SGRQ scores and most of the respiratory function test indices. A correlation between the severity of bronchiectatic disease as expressed in HRCT and the health-related quality of life exists in patients with a more severe bronchiectatic disease but not in patients with mild disease. Such correlation depends on the location of the bronchiectasis in the pulmonary tree.
Frueh, Florian S.; Körbel, Christina; Gassert, Laura; Müller, Andreas; Gousopoulos, Epameinondas; Lindenblatt, Nicole; Giovanoli, Pietro; Laschke, Matthias W.; Menger, Michael D.
2016-01-01
Secondary lymphedema is a common complication of cancer treatment characterized by chronic limb swelling with interstitial inflammation. The rodent hindlimb is a widely used model for the evaluation of novel lymphedema treatments. However, the assessment of limb volume in small animals is challenging. Recently, high-resolution three-dimensional (3D) imaging modalities have been introduced for rodent limb volumetry. In the present study we evaluated the validity of microcomputed tomography (μCT), magnetic resonance imaging (MRI) and ultrasound in comparison to conventional measuring techniques. For this purpose, acute lymphedema was induced in the mouse hindlimb by a modified popliteal lymphadenectomy. The 4-week course of this type of lymphedema was first assessed in 6 animals. In additional 12 animals, limb volumes were analyzed by μCT, 9.4 T MRI and 30 MHz ultrasound as well as by planimetry, circumferential length and paw thickness measurements. Interobserver correlation was high for all modalities, in particular for μCT analysis (r = 0.975, p < 0.001). Importantly, caliper-measured paw thickness correlated well with μCT (r = 0.861), MRI (r = 0.821) and ultrasound (r = 0.800). Because the assessment of paw thickness represents a time- and cost-effective approach, it may be ideally suited for the quantification of rodent hindlimb lymphedema. PMID:27698469
A method for evaluating models that use galaxy rotation curves to derive the density profiles
NASA Astrophysics Data System (ADS)
de Almeida, Álefe O. F.; Piattella, Oliver F.; Rodrigues, Davi C.
2016-11-01
There are some approaches, either based on General Relativity (GR) or modified gravity, that use galaxy rotation curves to derive the matter density of the corresponding galaxy, and this procedure would either indicate a partial or a complete elimination of dark matter in galaxies. Here we review these approaches, clarify the difficulties on this inverted procedure, present a method for evaluating them, and use it to test two specific approaches that are based on GR: the Cooperstock-Tieu (CT) and the Balasin-Grumiller (BG) approaches. Using this new method, we find that neither of the tested approaches can satisfactorily fit the observational data without dark matter. The CT approach results can be significantly improved if some dark matter is considered, while for the BG approach no usual dark matter halo can improve its results.
The Potential Application of Raw Cadmium Sulfide Nanoparticles as CT Photographic Developer
NASA Astrophysics Data System (ADS)
Wu, Qiang; Huang, Lingxin; Li, Zhan; An, Wenzhen; Liu, Dan; Lin, Jin; Tian, Longlong; Wang, Xinling; Liu, Bo; Qi, Wei; Wu, Wangsuo
2016-04-01
With the development of science and technology, new applications about nanoparticles should be explored to achieve full-scale knowledge. Therefore, in this work, the toxicity and potential application of raw cadmium sulfide nanoparticles (CdS) in vivo were further studied through ICP-OES and CTs. Surprisingly, CdS exhibited an excellent photographic property, except for finding the accumulation of CdS in the lungs, liver, spleen, and kidney with a strong dependence on time; it is also found that there were a significant uptake in the pancreas for an obvious CT imaging. And the following investigations showed that the raw CdS could damage the tissues accumulating nanoparticles. Through this work, it can be seen that the raw CdS being modified might be an excellent photographic developer for detecting cancers or other diseases.
Truong, Thi Ngoc Lien; Tran, Dai Lam; Vu, Thi Hong An; Tran, Vinh Hoang; Duong, Tuan Quang; Dinh, Quang Khieu; Tsukahara, Toshifumi; Lee, Young Hoon; Kim, Jong Seung
2010-01-15
In this paper, we describe DNA electrochemical detection for genetically modified organism (GMO) based on multi-wall carbon nanotubes (MWCNTs)-doped polypyrrole (PPy). DNA hybridization is studied by quartz crystal microbalance (QCM) and electrochemical impedance spectroscopy (EIS). An increase in DNA complementary target concentration results in a decrease in the faradic charge transfer resistance (R(ct)) and signifying "signal-on" behavior of MWCNTs-PPy-DNA system. QCM and EIS data indicated that the electroanalytical MWCNTs-PPy films were highly sensitive (as low as 4pM of target can be detected with QCM technique). In principle, this system can be suitable not only for DNA but also for protein biosensor construction.
Cai, Bo-Lei; Ren, Rong; Yu, Hong-Bo; Liu, Peng-Chao; Shen, Steve G F; Shi, Jun
2018-05-01
In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Ishak, Basem; Schneider, Till; Tubbs, R Shane; Gimmy, Valerie; Younsi, Alexander; Unterberg, Andreas W; Kiening, Karl L
2017-11-01
Various surgical techniques have been described for treating odontoid instability and achieving effective stabilization. The earliest technique to be described proposed a C1 lateral mass entry point including neurectomy of the C2 nerve roots to ensure hemostasis. Because C2 neurectomy remains controversial, preservation of the C2 nerve root as described in Goel-Harms technique can lead to intractable occipital neuralgia and significant blood loss. The aim of this study was to modify the Goel-Harms technique with a high C1 lateral mass screw entry point to enhance overall intraoperative safety. Sixty-three patients (average age, 70 ± 16 years) with acute traumatic odontoid fracture type II underwent posterior stabilization with a modified posterior C1 lateral mass entry point using intraoperative computed tomography (CT)-guided spinal navigation. Complications were recorded, especially bleeding from the epidural venous plexus and development of occipital neuralgia. All patients were followed up for a minimum of 6 months. None of the patients developed occipital neuralgia or numbness. Blood transfusion was necessary in 1 patient because of a coagulation disorder. There was no bleeding from the epidural venous plexus. All screws were correctly placed. Two patients needed surgical revision (wound infection, dural tear). Two developed cardiopulmonary complications. Solid bony fusion was achieved in all patients. This study confirms that changing the C1 entry point to the junction of the posterior arch and superior-posterior part of the C1 lateral mass by using intraoperative CT navigation yields a safe and effective procedure with few complications. The overall complication rate was 6%. Copyright © 2017 Elsevier Inc. All rights reserved.
Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fortunati, Valerio, E-mail: v.fortunati@erasmusmc.nl; Verhaart, René F.; Angeloni, Francesco
2014-09-01
Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealisticmore » deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration.« less
Tang, Weifeng; Zhang, Sheng; Qiu, Hao; Wang, Lixin; Sun, Bin; Yin, Jun; Gu, Haiyong
2014-05-01
Esophageal cancer is the sixth most common cancer worldwide. Esophageal squamous cell carcinoma (ESCC) is a fatal malignancy associated with low 5-year survival rate. The aim of this study was to assess the association between methylenetetrahydrofolate reductase (MTHFR) tagging single nucleotide polymorphisms (SNPs) rs1801133 C>T, rs3753584 A>G, rs4845882 G>A, rs4846048 A>G and rs9651118 T>C genotypes and ESCC susceptibility in a hospital-based case-control study. We conducted genotyping analyses for these five SNPs with 629 ESCC cases and 686 controls in a Chinese Han population. Ligation detection reaction method was used to identify genotypes of these MTHFR SNPs. Our results demonstrated that MTHFR rs1801133 C>T was associated with the risk of ESCC; however, MTHFR rs4845882 G>A and rs4846048 A>G SNPs were associated with the decreased risk of ESCC, and MTHFR rs3753584 A>G and rs9651118 T>C SNPs were not associated with ESCC risk. Our findings suggests that MTHFR rs1801133 C>T, rs4845882 G>A and rs4846048 A>G SNPs may be genetic modifiers for developing ESCC in Chinese Han population.
Zhang, Hua; Huang, Jing; Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan
2014-09-01
Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as "PWLS-PINL". Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.
Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan
2014-01-01
Repeated x-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the x-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as “PWLS-PINL”. Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive over-relaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection and edge detail preservation. PMID:24235272
Sekiguchi, Toshio; Kuwasako, Kenji; Ogasawara, Michio; Takahashi, Hiroki; Matsubara, Shin; Osugi, Tomohiro; Muramatsu, Ikunobu; Sasayama, Yuichi; Suzuki, Nobuo; Satake, Honoo
2016-01-29
The calcitonin (CT)/CT gene-related peptide (CGRP) family is conserved in vertebrates. The activities of this peptide family are regulated by a combination of two receptors, namely the calcitonin receptor (CTR) and the CTR-like receptor (CLR), and three receptor activity-modifying proteins (RAMPs). Furthermore, RAMPs act as escort proteins by translocating CLR to the cell membrane. Recently, CT/CGRP family peptides have been identified or inferred in several invertebrates. However, the molecular characteristics and relevant functions of the CTR/CLR and RAMPs in invertebrates remain unclear. In this study, we identified three CT/CGRP family peptides (Bf-CTFPs), one CTR/CLR-like receptor (Bf-CTFP-R), and three RAMP-like proteins (Bf-RAMP-LPs) in the basal chordate amphioxus (Branchiostoma floridae). The Bf-CTFPs were shown to possess an N-terminal circular region typical of the CT/CGRP family and a C-terminal Pro-NH2. The Bf-CTFP genes were expressed in the central nervous system and in endocrine cells of the midgut, indicating that Bf-CTFPs serve as brain and/or gut peptides. Cell surface expression of the Bf-CTFP-R was enhanced by co-expression with each Bf-RAMP-LP. Furthermore, Bf-CTFPs activated Bf-CTFP-R·Bf-RAMP-LP complexes, resulting in cAMP accumulation. These results confirmed that Bf-RAMP-LPs, like vertebrate RAMPs, are prerequisites for the function and translocation of the Bf-CTFP-R. The relative potencies of the three peptides at each receptor were similar. Bf-CTFP2 was a potent ligand at all receptors in cAMP assays. Bf-RAMP-LP effects on ligand potency order were distinct to vertebrate CGRP/adrenomedullin/amylin receptors. To the best of our knowledge, this is the first molecular and functional characterization of an authentic invertebrate CT/CGRP family receptor and RAMPs. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Haeussler, Silvia; Luepke, Matthias; Seifert, Hermann; Staszyk, Carsten
2014-02-21
In equine practice, teeth corrections by means of motorized grinding systems are standard procedure. The heat resulting from that treatment may cause irreparable damage to the dental pulp. It has been shown that a 5.5°C temperature rise may cause severe destruction in pulp cells. Hence, the capability to continuously form secondary dentine is lost, and may lead, due to equine-typical occlusal tooth abrasion, to an opening of the pulp cavity.To obtain reliable data on the intra-pulp increase in temperature during corrective treatments, equine cheek teeth (CT) were modified in a way (occlusal surface smoothed, apical parts detached, pulp horns standardized) that had been qualified in own former published studies. All parameters influencing the grinding process were standardized (force applied, initial temperatures, dimensions of pulp horns, positioning of grinding disk, rotational speed). During grinding experiments, imitating real dental treatments, the time span for an intra-pulp temperature increase of 5.5°C was determined. The minimum time recorded for an intra-pulp temperature increase of 5.5°C was 38 s in mandibular CT (buccal grinding, 12,000 rpm) and 70 s in maxillary CT (flat occlusal grinding, 12,000 rpm). The data obtained showed that doubling the rotational speed of the disk results in halving the time span after which the critical intra-pulp temperature increase in maxillary CT is reached. For mandibular CT, the time span even drops by two thirds. The use of standardized hypsodont CT enabled comparative studies of intra-pulp heating during the grinding of occlusal tooth surfaces using different tools and techniques. The anatomical structure of the natural vital hypsodont tooth must be kept in mind, so that the findings of this study do not create a deceptive sense of security with regard to the time-dependent heating of the native pulp.
2014-01-01
Background In equine practice, teeth corrections by means of motorized grinding systems are standard procedure. The heat resulting from that treatment may cause irreparable damage to the dental pulp. It has been shown that a 5.5°C temperature rise may cause severe destruction in pulp cells. Hence, the capability to continuously form secondary dentine is lost, and may lead, due to equine-typical occlusal tooth abrasion, to an opening of the pulp cavity. To obtain reliable data on the intra-pulp increase in temperature during corrective treatments, equine cheek teeth (CT) were modified in a way (occlusal surface smoothed, apical parts detached, pulp horns standardized) that had been qualified in own former published studies. All parameters influencing the grinding process were standardized (force applied, initial temperatures, dimensions of pulp horns, positioning of grinding disk, rotational speed). During grinding experiments, imitating real dental treatments, the time span for an intra-pulp temperature increase of 5.5°C was determined. Results The minimum time recorded for an intra-pulp temperature increase of 5.5°C was 38 s in mandibular CT (buccal grinding, 12,000 rpm) and 70 s in maxillary CT (flat occlusal grinding, 12,000 rpm). The data obtained showed that doubling the rotational speed of the disk results in halving the time span after which the critical intra-pulp temperature increase in maxillary CT is reached. For mandibular CT, the time span even drops by two thirds. Conclusion The use of standardized hypsodont CT enabled comparative studies of intra-pulp heating during the grinding of occlusal tooth surfaces using different tools and techniques. The anatomical structure of the natural vital hypsodont tooth must be kept in mind, so that the findings of this study do not create a deceptive sense of security with regard to the time-dependent heating of the native pulp. PMID:24559121
Bhure, U N; Lardinois, D; Kalff, V; Hany, T F; Soltermann, A; Seifert, B; Steinert, H C
2010-10-01
Accurate determination of tumour size in lung adenocarcinoma with bronchoalveolar features (BAC) is important for the determination of TNM (tumour, nodes, metastasis) scores used in staging, prognosis and therapy response assessment. However, tumour sizes derived using lung window (LW) CT or soft-tissue/mediastinal window (MW) CT often give different results. This study examines which measurement correlates best with actual tumour size and which best identifies advanced disease. This retrospective study included 43 BAC patients who underwent surgical resection with mediastinal lymphadenectomy <4 weeks post CT scan. The largest unidimensional tumour diameter on each CT window was compared with actual histopathological tumour size (HP). LW, MW and HP size measurements and a recently described CT parameter - the modified tumour shadow disappearance rate (mTDR) = (1 - [MW/LW]) - were then used to determine which parameter best discriminated between the presence or absence of advanced disease. There was no difference between HP and LW sizes, but MW significantly underestimated HP size (p<0.0001). Unlike MW (p = 0.01) and mTDR (p = 0.001), neither HP (p = 0.14) nor LW (p = 0.10) distinguished between patients with or without advanced disease. On receiver operating characteristic (ROC) analysis at a cut-off of ≤0.13, the sensitivity and specificity of mTDR for detecting advanced disease were 69% and 89%, respectively. In patients with tumours ≤3 cm, only mTDR remained a significant predictor of advanced disease (p = 0.017), with best cut-off at ≤0.20, giving a sensitivity and specificity of 71% and 94%, respectively. MW better predicts advanced disease than LW and might also need to be recorded for RECIST (response evaluation criteria in solid tumours) assessment for T staging of BAC; however, mTDR appears to be an even better predictor and should also be used.
Decreased occipital lobe metabolism by FDG-PET/CT
Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun
2017-01-01
Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p < 0.0005; medial occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205
Lee, Tih-Shih; Quek, Shin Yi; Goh, Siau Juinn Alexa; Phillips, Rachel; Guan, Cuntai; Cheung, Yin Bun; Feng, Lei; Wang, Chuan Chu; Chin, Zheng Yang; Zhang, Haihong; Lee, Jimmy; Ng, Tze Pin; Krishnan, K Ranga Rama
2015-01-01
There is growing evidence that cognitive training (CT) can improve the cognitive functioning of the elderly. CT may be influenced by cultural and linguistic factors, but research examining CT programs has mostly been conducted on Western populations. We have developed an innovative electroencephalography (EEG)-based brain-computer interface (BCI) CT program that has shown preliminary efficacy in improving cognition in 32 healthy English-speaking elderly adults in Singapore. In this second pilot trial, we examine the acceptability, safety, and preliminary efficacy of our BCI CT program in healthy Chinese-speaking Singaporean elderly. Thirty-nine elderly participants were randomized into intervention (n=21) and wait-list control (n=18) arms. Intervention consisted of 24 half-hour sessions with our BCI-based CT training system to be completed in 8 weeks; the control arm received the same intervention after an initial 8-week waiting period. At the end of the training, a usability and acceptability questionnaire was administered. Efficacy was measured using the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS), which was translated and culturally adapted for the Chinese-speaking local population. Users were asked about any adverse events experienced after each session as a safety measure. The training was deemed easily usable and acceptable by senior users. The median difference in the change scores pre- and post-training of the modified RBANS total score was 8.0 (95% confidence interval [CI]: 0.0-16.0, P=0.042) higher in the intervention arm than waitlist control, while the mean difference was 9.0 (95% CI: 1.7-16.2, P=0.017). Ten (30.3%) participants reported a total of 16 adverse events - all of which were graded "mild" except for one graded "moderate". Our BCI training system shows potential in improving cognition in both English- and Chinese-speaking elderly, and deserves further evaluation in a Phase III trial. Overall, participants responded positively on the usability and acceptability questionnaire.
Kanczler, Janos M; Smith, Emma L; Roberts, Carol A; Oreffo, Richard O C
2012-10-01
Understanding the structural development of embryonic bone in a three dimensional framework is fundamental to developing new strategies for the recapitulation of bone tissue in latter life. We present an innovative combined approach of an organotypic embryonic femur culture model, microcomputed tomography (μCT) and immunohistochemistry to examine the development and modulation of the three dimensional structures of the developing embryonic femur. Isolated embryonic chick femurs were organotypic (air/liquid interface) cultured for 10 days in either basal, chondrogenic, or osteogenic supplemented culture conditions. The growth development and modulating effects of basal, chondrogenic, or osteogenic culture media of the embryonic chick femurs was investigated using μCT, immunohistochemistry, and histology. The growth and development of noncultured embryonic chick femur stages E10, E11, E12, E13, E15, and E17 were very closely correlated with increased morphometric indices of bone formation as determined by μCT. After 10 days in the organotpyic culture set up, the early aged femurs (E10 and E11) demonstrated a dramatic response to the chondrogenic or osteogenic culture conditions compared to the basal cultured femurs as determined by a change in μCT morphometric indices and modified expression of chondrogenic and osteogenic markers. Although the later aged femurs (E12 and E13) increased in size and structure after 10 days organotpypic culture, the effects of the osteogenic and chondrogenic organotypic cultures on these femurs were not significantly altered compared to basal conditions. We have demonstrated that the embryonic chick femur organotpyic culture model combined with the μCT and immunohistochemical analysis can provide an integral methodology for investigating the modulation of bone development in an ex vivo culture setting. Hence, these interdisciplinary techniques of μCT and whole organ bone cultures will enable us to delineate some of the temporal, structural developmental paradigms and modulation of bone tissue formation to underpin innovative skeletal regenerative technology for clinical therapeutic strategies in musculoskeletal trauma and diseases.
Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G
2003-01-01
To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (p<0.001), and the 1-month CT volume was 43.6 cm(3) (p<0.001). The mean difference between the OR dose received by 90% of the prostate (D(90)) and the CT D(90) was 3.4% (95% confidence interval, 2.5-6.6%; p=0.034). The mean dose to 30% of the urethra was 120% of prescription in the OR and 138% on CT. The mean difference was 18% (95% confidence interval, 13-24%; p<0.001). Although small differences exist between the OR and CT dosimetry results, these data suggest that this intraoperative implant dosimetric representation system provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.
Wahba, Roger; Franke, Mareike; Hellmich, Martin; Kleinert, Robert; Cingöz, Tülay; Schmidt, Matthias C; Stippel, Dirk L; Bangard, Christopher
2016-06-01
Transplant centers commonly evaluate split renal function (SRF) with Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy in living kidney donation. Alternatively, the kidney volume can be measured based on predonation CT scans. The aim of this study was to identify the most accurate CT volumetry technique for SRF and the prediction of postdonation kidney function (PDKF). Three CT volumetry techniques (modified ellipsoid volume [MELV], smart region of interest [ROI] volume, renal cortex volume [RCV]) were performed in 101 living kidney donors. Preoperation CT volumetric SRF was determined and compared with MAG3-SRF, postoperation donor kidney function, and graft function. The correlation between donors predonation total kidney volume and predonation kidney function was the highest for RCV (0.58 with creatine clearance, 0.54 with estimated glomerular filtration rate-Cockcroft-Gault). The predonation volume of the preserved kidney was (ROI, MELV, RCV) 148.0 ± 29.1 cm, 151.2 ± 35.4 and 93.9 ± 25.2 (P < 0.005 MELV vs RCV and ROI vs RCV). Bland-Altman analysis showed agreement between CT volumetry SRF and MAG3-SRF (bias, 95% limits of agreement: ROI vs MAG3 0.4%, -7.7% to 8.6%; MELV vs MAG3 0.4%, -8.9% to 9.7%; RCV vs MAG3 0.8%, -9.1% to 10.7%). The correlation between predonation CT volumetric SRF of the preserved kidney and PDKF at day 3 was r = 0.85 to 0.88, between MAG3-SRF and PDKF (r = 0.84). The difference of predonation SRF between preserved and donated kidney was the lowest for ROI and RCV (median, 3% and 4%; 95th percentile, 9% and 13%). Overall renal cortex volumetry seems to be the most accurate technique for the evaluation of predonation SRF and allows a reliable prediction of donor's PDKF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomson, David J.; The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester; Beasley, William J.
Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial andmore » second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.« less
Kha, Lan-Chau T; Hanneman, Kate; Donahoe, Laura; Chung, Taebong; Pierre, Andrew F; Yasufuku, Kazuhiro; Keshavjee, Shafique; Mayo, John R; Paul, Narinder S; Nguyen, Elsie T
2016-01-01
The purpose of this pilot study was to evaluate the safety and efficacy of preoperative computed tomography (CT)-guided percutaneous microcoil lung nodule localization without pleural marking compared with the established technique with pleural marking. Sixty-three consecutive patients (66.7% female, mean age 61.6±11.4 y) with 64 lung nodules resected between October 2008 and January 2014 were retrospectively evaluated. Of the nodules, 29.7% (n=19) had microcoil deployment with pleural marking (control group) and 70.3% (n=45) had microcoil deployment without pleural marking (pilot group). Clinical, pathologic, and imaging characteristics, radiation dose, CT procedure and operating room time, and complete resection and complication rates were compared between the pilot and control groups. There was no significant difference in nodule size (P=0.552) or distance from the pleural surface (P=0.222) between the pilot and control groups. However, mean procedure duration (53.6±18.3 vs. 72.8±25.3 min, P=0.001) and total effective radiation dose (5.1±2.6 vs. 7.1±4.9 mSv, P=0.039) were significantly lower in the pilot group compared with the control group. CT procedure-related complications (P=0.483) [including pneumothoraces (P=0.769) and pulmonary hemorrhage (P=1.000)], operating room time (P=0.926), complete resection rates (P=0.520), intraoperative complications (P=0.549), and postoperative complications (P=1.000) were similar between the pilot and control groups. Preoperative CT-guided lung nodule microcoil localization performed without visceral pleural marking appears to decrease the CT procedure time and radiation dose while maintaining equivalent complete resection rates and procedural and surgical complications, when compared with microcoil localization performed with pleural marking.
Ujike, Makoto; Nakajima, Katsuhisa; Nobusawa, Eri
2004-11-01
The cytoplasmic tail (CT) of hemagglutinin (HA) of influenza B virus (BHA) contains at positions 578 and 581 two highly conserved cysteine residues (Cys578 and Cys581) that are modified with palmitic acid (PA) through a thioester linkage. To investigate the role of PA in the fusion activity of BHA, site-specific mutagenesis was performed with influenza B virus B/Kanagawa/73 HA cDNA. All of the HA mutants were expressed on Cos cells by an expression vector. The membrane fusion ability of the HA mutants at a low pH was quantitatively examined with lipid (octadecyl rhodamine B chloride) and aqueous (calcein) dye transfer assays and with the syncytium formation assay. Two deacylation mutants lacking a CT or carrying serine residues substituting for Cys578 and Cys581 promoted full fusion. However, one of the single-acylation-site mutants, C6, in which Cys581 is replaced with serine, promoted hemifusion but not pore formation. In contrast, four other single-acylation-site mutants that have a sole cysteine residue in the CT at position 575, 577, 579, or 581 promoted full fusion. The impaired pore-forming ability of C6 was improved by amino acid substitution between residues 578 and 582 or by deletion of the carboxy-terminal leucine at position 582. Syncytium-forming ability, however, was not adequately restored by these mutations. These facts indicated that the acylation was not significant in membrane fusion by BHA but that pore formation and pore dilation were appreciably affected by the particular amino acid sequence of the CT and the existence of a single acylation site in CT residue 578.
Peripheral gustatory processing of sweet stimuli by golden hamsters.
Frank, Marion E; Formaker, Bradley K; Hettinger, Thomas P
2005-07-15
Behaviors and taste-nerve responses to bitter stimuli are linked to compounds that bind T2 receptors expressed in one subset of taste-bud receptor cells (TRCs); and behavioral and neural responses to sweet stimuli are linked to chemical compounds that bind a T1 receptor expressed in a different TRC subset. Neural and behavioral responses to bitter-sweet mixtures, however, complicate the ostensible bitter and sweet labeled lines. In the golden hamster, Mesocricetus auratus, quinine hydrochloride, the bitter prototype, suppresses chorda tympani (CT) nerve responses to the sweet prototype: sucrose. This bitter-sweet inhibition was tested with concentration series of sucrose and dulcin, a hydrophobic synthetic sweetener that hamsters behaviorally cross-generalize with sucrose. Dulcin, sucrose and other sweeteners activate one subset of CT fibers: S neurons; whereas, quinine activates a separate subset of CT fibers: E neurons. Whole-nerve and S-neuron CT responses to a sweetener concentration series, mixed with 0, 1, 3 and 10 mM quinine, were measured for 0-2.5 s transient and/or 2.6-10 s steady-state response periods. Ten-sec total single-fiber records, aligned at response onset, were averaged for 100 ms bins to identify response oscillations. Quinine inhibition of dulcin and sucrose responses was identical. Each log molar increment in quinine resulted in equivalent declines in response to either sweetener. Furthermore, sucrose response decrements paralleled response increments in quinine-sensitive CT neurons to the same quinine increases. A 1.43 Hz bursting rhythm to the sweeteners was unchanged by quinine inhibition or decreases in sweetener concentration. Taste-bud processing, possibly between-cell inhibition and within-cell negative feedback, must modify signals initiated by T1 receptors before they are transmitted to the brain.
Influence of CT automatic tube current modulation on uncertainty in effective dose.
Sookpeng, S; Martin, C J; Gentle, D J
2016-01-01
Computed tomography (CT) scanners are equipped with automatic tube current modulation (ATCM) systems that adjust the current to compensate for variations in patient attenuation. CT dosimetry variables are not defined for ATCM situations and, thus, only the averaged values are displayed and analysed. The patient effective dose (E), which is derived from a weighted sum of organ equivalent doses, will be modified by the ATCM. Values for E for chest-abdomen-pelvis CT scans have been calculated using the ImPACT spreadsheet for patients on five CT scanners. Values for E resulting from the z-axis modulation under ATCM have been compared with results assessed using the same effective mAs values with constant tube currents. Mean values for E under ATCM were within ±10 % of those for fixed tube currents for all scanners. Cumulative dose distributions under ATCM have been simulated for two patient scans using single-slice dose profiles measured in elliptical and cylindrical phantoms on one scanner. Contributions to the effective dose from organs in the upper thorax under ATCM are 30-35 % lower for superficial tissues (e.g. breast) and 15-20 % lower for deeper organs (e.g. lungs). The effect on doses to organs in the abdomen depends on body shape, and they can be 10-22 % higher for larger patients. Results indicate that scan dosimetry parameters, dose-length product and effective mAs averaged over the whole scan can provide an assessment in terms of E that is sufficiently accurate to quantify relative risk for routine patient exposures under ATCM. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Novotny, Vojtech; Nacu, Aliona; Kvistad, Christopher E; Fromm, Annette; Neckelmann, Gesche F; Khanevski, Andrej N; Tobro, Haakon; Waje-Andreassen, Ulrike; Naess, Halvor; Thomassen, Lars; Logallo, Nicola
2017-11-08
Contrast-enhanced sonothrombolysis (CEST) seems to be a safe and promising treatment in acute ischemic stroke. It remains unknown if temporal bone features may influence the efficacy of CEST. We investigated the association between different temporal bone features on admission computed tomography (CT) scan and the outcome in acute ischemic stroke patients included in the randomized Norwegian Sonothrombolysis in Acute Stroke Study (NOR-SASS). Patients diagnosed as stroke mimics and those with infratentorial stroke or with incorrect insonation were excluded. We retrospectively assessed temporal bone heterogeneity (presence of diploë), diploë ratio, thickness, and density on admission CT scans. National institute of Health Stroke Scale (NIHSS) at 24 h and modified Rankin Scale (mRS) at 3 months were correlated with CT findings both in CEST and sham CEST patients. A total of 99 patients were included of which 52 were assigned to CEST and 47 to sham CEST. Approximately 20% patients had a heterogeneous temporal bone in both the CEST and sham CEST group. All temporal bone CT features studied were associated with female sex. In the CEST group, temporal bone heterogeneity (p = 0.006) and higher temporal bone diploë ratio (p = 0.002) were associated with higher NIHSS at 24 h. There was no association between temporal bone features and mRS at 3 months. Approximately 20% of acute ischemic stroke patients have heterogeneous temporal bone and may be resistant to standard 2-MHz transcranial Doppler ultrasound treatment. Sonothrombolysis resistance may easily be predicted by admission CT for better selection.
Evaluation of physical activity measures used in middle-aged women.
Pettee Gabriel, Kelley; McClain, James J; Lee, Chong D; Swan, Pamela D; Alvar, Brent A; Mitros, Melanie R; Ainsworth, Barbara E
2009-07-01
To evaluate the reliability and validity of five commonly used physical activity questionnaires (PAQ) in women aged 45-65 yr with varying physical activity (PA) levels. Data were obtained from the Evaluation of Physical Activity Measures in Middle-aged Women (PAW) Study and included 66 women (aged 52.6 +/- 5.4 yr). PAQ evaluated include Modifiable Activity Questionnaire (past week and past month version), Nurses' Health Study PAQ, Active Australia Survey, and Women's Health Initiative PAQ. Intraclass correlation coefficients (ICC) between administrations of the PAQ were used to assess test-retest reliability. Spearman rank-order correlation coefficients were used to examine the associations of PA and physical fitness data with PAQ summary estimates. Accelerometer-determined median (25th, 75th percentiles) times (min.d) spent in moderate-lifestyle [760-1951 counts (ct)], moderate-walk (1952-5724 ct), vigorous (> or =5725 ct), and combined moderate and vigorous PA (MVPA > or = 1952 ct) during the 35 d of observation were 66.0 (51.2, 81.3), 23.1 (14.1, 34.6), 0.4 (0.0, 2.3), and 24.3 (15.9, 41.6) min, respectively. The PAQ were shown to be reproducible and relatively stable over time (ICC = 0.32 to 0.91) and were associated with total counts per day (ct.d, 0.46 to 0.60, all P < 0.001), and most were associated with many facets of physical fitness, including cardiorespiratory fitness (0.36 to 0.46, P < 0.01), body composition (-0.27 to -0.34, P < 0.05), and muscular fatigue (-0.25 to -0.44, P < 0.05). The PAQ evaluated in this study were shown to be reliable and associated with PA and physical fitness measures. Current findings support the utility of these PAQ for PA assessment in research studies of middle-aged women.
Computer tool to evaluate the cue reactivity of chemically dependent individuals.
Silva, Meire Luci da; Frère, Annie France; Oliveira, Henrique Jesus Quintino de; Martucci Neto, Helio; Scardovelli, Terigi Augusto
2017-03-01
Anxiety is one of the major influences on the dropout of relapse and treatment of substance abuse treatment. Chemically dependent individuals need (CDI) to be aware of their emotional state in situations of risk during their treatment. Many patients do not agree with the diagnosis of the therapist when considering them vulnerable to environmental stimuli related to drugs. This research presents a cue reactivity detection tool based on a device acquiring physiological signals connected to personal computer. Depending on the variations of the emotional state of the drug addict, alteration of the physiological signals will be detected by the computer tool (CT) which will modify the displayed virtual sets without intervention of the therapist. Developed in 3ds Max® software, the CT is composed of scenarios and objects that are in the habit of marijuana and cocaine dependent individual's daily life. The interaction with the environment is accomplished using a Human-Computer Interface (HCI) that converts incoming physiological signals indicating anxiety state into commands that change the scenes. Anxiety was characterized by the average variability from cardiac and respiratory rate of 30 volunteers submitted stress environment situations. To evaluate the effectiveness of cue reactivity a total of 50 volunteers who were marijuana, cocaine or both dependent were accompanied. Prior to CT, the results demonstrated a poor correlation between the therapists' predictions and those of the chemically dependent individuals. After exposure to the CT, there was a significant increase of 73% in awareness of the risks of relapse. We confirmed the hypothesis that the CT, controlled only by physiological signals, increases the perception of vulnerability to risk situations of individuals with dependence on marijuana, cocaine or both. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Aurumskjöld, Marie-Louise; Söderberg, Marcus; Stålhammar, Fredrik; von Steyern, Kristina Vult; Tingberg, Anders; Ydström, Kristina
2018-06-01
Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose 4 ), and images from the low-dose examinations were reconstructed with both iDose 4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose 4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose 4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60-0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose 4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiaojian; Qiao, Qiao; Department of Radiotherapy, First Hospital of China Medical University, Shenyang
Purpose: To evaluate the efficiency of standard image-guided radiation therapy (IGRT) to account for lumpectomy cavity (LC) variation during whole-breast irradiation (WBI) and propose an adaptive strategy to improve dosimetry if IGRT fails to address the interfraction LC variations. Methods and Materials: Daily diagnostic-quality CT data acquired during IGRT in the boost stage using an in-room CT for 19 breast cancer patients treated with sequential boost after WBI in the prone position were retrospectively analyzed. Contours of the LC, treated breast, ipsilateral lung, and heart were generated by populating contours from planning CTs to boost fraction CTs using an auto-segmentationmore » tool with manual editing. Three plans were generated on each fraction CT: (1) a repositioning plan by applying the original boost plan with the shift determined by IGRT; (2) an adaptive plan by modifying the original plan according to a fraction CT; and (3) a reoptimization plan by a full-scale optimization. Results: Significant variations were observed in LC. The change in LC volume at the first boost fraction ranged from a 70% decrease to a 50% increase of that on the planning CT. The adaptive and reoptimization plans were comparable. Compared with the repositioning plans, the adaptive plans led to an improvement in target coverage for an increased LC case (1 of 19, 7.5% increase in planning target volume evaluation volume V{sub 95%}), and breast tissue sparing for an LC decrease larger than 35% (3 of 19, 7.5% decrease in breast evaluation volume V{sub 50%}; P=.008). Conclusion: Significant changes in LC shape and volume at the time of boost that deviate from the original plan for WBI with sequential boost can be addressed by adaptive replanning at the first boost fraction.« less
NASA Astrophysics Data System (ADS)
Zikmund, T.; Novotná, M.; Kavková, M.; Tesařová, M.; Kaucká, M.; Szarowská, B.; Adameyko, I.; Hrubá, E.; Buchtová, M.; Dražanová, E.; Starčuk, Z.; Kaiser, J.
2018-02-01
The biomedically focused brain research is largely performed on laboratory mice considering a high homology between the human and mouse genomes. A brain has an intricate and highly complex geometrical structure that is hard to display and analyse using only 2D methods. Applying some fast and efficient methods of brain visualization in 3D will be crucial for the neurobiology in the future. A post-mortem analysis of experimental animals' brains usually involves techniques such as magnetic resonance and computed tomography. These techniques are employed to visualize abnormalities in the brains' morphology or reparation processes. The X-ray computed microtomography (micro CT) plays an important role in the 3D imaging of internal structures of a large variety of soft and hard tissues. This non-destructive technique is applied in biological studies because the lab-based CT devices enable to obtain a several-micrometer resolution. However, this technique is always used along with some visualization methods, which are based on the tissue staining and thus differentiate soft tissues in biological samples. Here, a modified chemical contrasting protocol of tissues for a micro CT usage is introduced as the best tool for ex vivo 3D imaging of a post-mortem mouse brain. This way, the micro CT provides a high spatial resolution of the brain microscopic anatomy together with a high tissue differentiation contrast enabling to identify more anatomical details in the brain. As the micro CT allows a consequent reconstruction of the brain structures into a coherent 3D model, some small morphological changes can be given into context of their mutual spatial relationships.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orza, Anamaria; Wu, Hui; Li, Yuancheng
Purpose: To develop a core/shell nanodimer of gold (core) and silver iodine (shell) as a dual-modal contrast-enhancing agent for biomarker targeted x-ray computed tomography (CT) and photoacoustic imaging (PAI) applications. Methods: The gold and silver iodine core/shell nanodimer (Au/AgICSD) was prepared by fusing together components of gold, silver, and iodine. The physicochemical properties of Au/AgICSD were then characterized using different optical and imaging techniques (e.g., HR- transmission electron microscope, scanning transmission electron microscope, x-ray photoelectron spectroscopy, energy-dispersive x-ray spectroscopy, Z-potential, and UV-vis). The CT and PAI contrast-enhancing effects were tested and then compared with a clinically used CT contrast agentmore » and Au nanoparticles. To confer biocompatibility and the capability for efficient biomarker targeting, the surface of the Au/AgICSD nanodimer was modified with the amphiphilic diblock polymer and then functionalized with transferrin for targeting transferrin receptor that is overexpressed in various cancer cells. Cytotoxicity of the prepared Au/AgICSD nanodimer was also tested with both normal and cancer cell lines. Results: The characterizations of prepared Au/AgI core/shell nanostructure confirmed the formation of Au/AgICSD nanodimers. Au/AgICSD nanodimer is stable in physiological conditions for in vivo applications. Au/AgICSD nanodimer exhibited higher contrast enhancement in both CT and PAI for dual-modality imaging. Moreover, transferrin functionalized Au/AgICSD nanodimer showed specific binding to the tumor cells that have a high level of expression of the transferrin receptor. Conclusions: The developed Au/AgICSD nanodimer can be used as a potential biomarker targeted dual-modal contrast agent for both or combined CT and PAI molecular imaging.« less
Flores-Villanueva, Pedro O; Ganachari, Malathesha; Guio, Heinner; Mejia, Jaime A; Granados, Julio
2018-04-15
Lung cancer is a leading cause of cancer-related death among both men and women in the United States, where non-small cell lung cancer accounts for ∼85% of lung cancer. Lung adenocarcinoma (ADC) is the major histologic subtype. The presence of actionable mutations prompts the use of therapies designed to specifically address the deleterious effects of those cancer-driving mutations; these therapies have already shown promise in cases carrying those actionable mutations (∼30%). Innovative therapeutic approaches are needed for the treatment of 70% of patients suffering from lung ADC. Adoptive transfer of CD8 + T cells specific against cancer/testis (CT) Ags, whose protein expression is restricted to the gonads (testis and ovary) and cancerous cells, is an excellent alternative. In this study, we report the isolation of HLA-A*02:01/CT37 peptide-specific α and β TCR chains from a CD8 + T cell clone obtained from a patient suffering from lung ADC. We also report the development of an innovative CD3ζ construct. With those TCR chains and the engineered (modified) CD3ζ chain, we produced a construct that when transduced into CD8 + T cells is capable of redirecting transduced CD8 + T cell cytotoxic activity and IFN-γ secretion against peptide-pulsed autologous cells and HLA-A*02:01 -positive and CT37-expressing lung ADC cell lines. Our findings will launch the development of innovative adoptive transfer immunotherapies for the treatment of lung ADC, targeting the most prevalent HLA molecules and CT37 peptides restricted by these molecules. Copyright © 2018 by The American Association of Immunologists, Inc.
Guio, Heinner
2018-01-01
Lung cancer is a leading cause of cancer-related death among both men and women in the United States, where non–small cell lung cancer accounts for ∼85% of lung cancer. Lung adenocarcinoma (ADC) is the major histologic subtype. The presence of actionable mutations prompts the use of therapies designed to specifically address the deleterious effects of those cancer-driving mutations; these therapies have already shown promise in cases carrying those actionable mutations (∼30%). Innovative therapeutic approaches are needed for the treatment of 70% of patients suffering from lung ADC. Adoptive transfer of CD8+ T cells specific against cancer/testis (CT) Ags, whose protein expression is restricted to the gonads (testis and ovary) and cancerous cells, is an excellent alternative. In this study, we report the isolation of HLA-A*02:01/CT37 peptide–specific α and β TCR chains from a CD8+ T cell clone obtained from a patient suffering from lung ADC. We also report the development of an innovative CD3ζ construct. With those TCR chains and the engineered (modified) CD3ζ chain, we produced a construct that when transduced into CD8+ T cells is capable of redirecting transduced CD8+ T cell cytotoxic activity and IFN-γ secretion against peptide-pulsed autologous cells and HLA-A*02:01–positive and CT37-expressing lung ADC cell lines. Our findings will launch the development of innovative adoptive transfer immunotherapies for the treatment of lung ADC, targeting the most prevalent HLA molecules and CT37 peptides restricted by these molecules. PMID:29555781
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noid, G; Tai, A; Li, X
2016-06-15
Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with themore » high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery. Supported by Siemens.« less
Hamada, Taku; Kotani, Kazuhiko; Fujiwara, Shinji; Sano, Yoshiko; Domichi, Masayuki; Tsuzaki, Kokoro; Sakane, Naoki
2008-03-01
Uncoupling protein 3 (UCP3) is considered to be associated with obesity, given its function in the regulation of energy and lipid metabolism. An increased body mass index (BMI) and a decreased level of high-density lipoprotein cholesterol (HDL-C) are risk factors for cardiovascular disease. The purpose of this study was to investigate whether the UCP3 promoter -55 C/T single nucleotide polymorphism (UCP3 -55 C/T SNP) was associated with obesity according to the criteria for Japanese (BMI > or = 25 kg/m2), BMI, and serum HDL-C levels in the general Japanese population. The subjects, numbering 282 and aged 65 +/- 13 years (mean +/- SD), were recruited through an annual health checkup of residents of Mima city, Tokushima, in Japan. Body mass index, blood pressure, biochemical indexes including lipid, and lipoprotein profiles were measured. The UCP3 -55 C/T SNP was determined with a fluorescence-based allele-specific DNA primer assay system. The frequency of the -55 T allele was 30.0%. Subjects with the T/T genotype had significantly higher HDL-C levels than those with the C/C genotype or the C/T genotype. Furthermore, subjects with the T/T genotype had a significantly lower BMI than those with the C/C genotype. A multivariate analysis revealed that the -55 T allele was a significant independent variable contributing to the variance in HDL-C levels and BMI. The T/T genotype was associated with a lower prevalence of obesity than the C/C and C/T genotypes, with an odds ratio of 0.358 (95% confidence interval, 0.132-0.972; P = .037). In conclusion, the UCP3 -55 C/T SNP was associated with elevated HDL-C levels and a reduced BMI, independent of modifiable factors such as lifestyle. Furthermore, this polymorphism, when expressed in its homozygous form, reduced the prevalence of obesity in Japanese.
2013-01-01
Background In the present study, we used multimodal imaging to investigate biodistribution in rats after intravenous administration of a new 99mTc-labeled delivery system consisting of polymer-shelled microbubbles (MBs) functionalized with diethylenetriaminepentaacetic acid (DTPA), thiolated poly(methacrylic acid) (PMAA), chitosan, 1,4,7-triacyclononane-1,4,7-triacetic acid (NOTA), NOTA-super paramagnetic iron oxide nanoparticles (SPION), or DTPA-SPION. Methods Examinations utilizing planar dynamic scintigraphy and hybrid imaging were performed using a commercially available single-photon emission computed tomography (SPECT)/computed tomography (CT) system. For SPION containing MBs, the biodistribution pattern of 99mTc-labeled NOTA-SPION and DTPA-SPION MBs was investigated and co-registered using fusion SPECT/CT and magnetic resonance imaging (MRI). Moreover, to evaluate the biodistribution, organs were removed and radioactivity was measured and calculated as percentage of injected dose. Results SPECT/CT and MRI showed that the distribution of 99mTc-labeled ligand-functionalized MBs varied with the type of ligand as well as with the presence of SPION. The highest uptake was observed in the lungs 1 h post injection of 99mTc-labeled DTPA and chitosan MBs, while a similar distribution to the lungs and the liver was seen after the administration of PMAA MBs. The highest counts of 99mTc-labeled NOTA-SPION and DTPA-SPION MBs were observed in the lungs, liver, and kidneys 1 h post injection. The highest counts were observed in the liver, spleen, and kidneys as confirmed by MRI 24 h post injection. Furthermore, the results obtained from organ measurements were in good agreement with those obtained from SPECT/CT. Conclusions In conclusion, microbubbles functionalized by different ligands can be labeled with radiotracers and utilized for SPECT/CT imaging, while the incorporation of SPION in MB shells enables imaging using MR. Our investigation revealed that biodistribution may be modified using different ligands. Furthermore, using a single contrast agent with fusion SPECT/CT/MR multimodal imaging enables visualization of functional and anatomical information in one image, thus improving the diagnostic benefit for patients. PMID:23442550
Randomized assessment of rapid endovascular treatment of ischemic stroke.
Goyal, Mayank; Demchuk, Andrew M; Menon, Bijoy K; Eesa, Muneer; Rempel, Jeremy L; Thornton, John; Roy, Daniel; Jovin, Tudor G; Willinsky, Robert A; Sapkota, Biggya L; Dowlatshahi, Dar; Frei, Donald F; Kamal, Noreen R; Montanera, Walter J; Poppe, Alexandre Y; Ryckborst, Karla J; Silver, Frank L; Shuaib, Ashfaq; Tampieri, Donatella; Williams, David; Bang, Oh Young; Baxter, Blaise W; Burns, Paul A; Choe, Hana; Heo, Ji-Hoe; Holmstedt, Christine A; Jankowitz, Brian; Kelly, Michael; Linares, Guillermo; Mandzia, Jennifer L; Shankar, Jai; Sohn, Sung-Il; Swartz, Richard H; Barber, Philip A; Coutts, Shelagh B; Smith, Eric E; Morrish, William F; Weill, Alain; Subramaniam, Suresh; Mitha, Alim P; Wong, John H; Lowerison, Mark W; Sajobi, Tolulope T; Hill, Michael D
2015-03-12
Among patients with a proximal vessel occlusion in the anterior circulation, 60 to 80% of patients die within 90 days after stroke onset or do not regain functional independence despite alteplase treatment. We evaluated rapid endovascular treatment in addition to standard care in patients with acute ischemic stroke with a small infarct core, a proximal intracranial arterial occlusion, and moderate-to-good collateral circulation. We randomly assigned participants to receive standard care (control group) or standard care plus endovascular treatment with the use of available thrombectomy devices (intervention group). Patients with a proximal intracranial occlusion in the anterior circulation were included up to 12 hours after symptom onset. Patients with a large infarct core or poor collateral circulation on computed tomography (CT) and CT angiography were excluded. Workflow times were measured against predetermined targets. The primary outcome was the score on the modified Rankin scale (range, 0 [no symptoms] to 6 [death]) at 90 days. A proportional odds model was used to calculate the common odds ratio as a measure of the likelihood that the intervention would lead to lower scores on the modified Rankin scale than would control care (shift analysis). The trial was stopped early because of efficacy. At 22 centers worldwide, 316 participants were enrolled, of whom 238 received intravenous alteplase (120 in the intervention group and 118 in the control group). In the intervention group, the median time from study CT of the head to first reperfusion was 84 minutes. The rate of functional independence (90-day modified Rankin score of 0 to 2) was increased with the intervention (53.0%, vs. 29.3% in the control group; P<0.001). The primary outcome favored the intervention (common odds ratio, 2.6; 95% confidence interval, 1.7 to 3.8; P<0.001), and the intervention was associated with reduced mortality (10.4%, vs. 19.0% in the control group; P=0.04). Symptomatic intracerebral hemorrhage occurred in 3.6% of participants in intervention group and 2.7% of participants in control group (P=0.75). Among patients with acute ischemic stroke with a proximal vessel occlusion, a small infarct core, and moderate-to-good collateral circulation, rapid endovascular treatment improved functional outcomes and reduced mortality. (Funded by Covidien and others; ESCAPE ClinicalTrials.gov number, NCT01778335.).
High-throughput real-time quantitative reverse transcription PCR.
Bookout, Angie L; Cummins, Carolyn L; Mangelsdorf, David J; Pesola, Jean M; Kramer, Martha F
2006-02-01
Extensive detail on the application of the real-time quantitative polymerase chain reaction (QPCR) for the analysis of gene expression is provided in this unit. The protocols are designed for high-throughput, 384-well-format instruments, such as the Applied Biosystems 7900HT, but may be modified to suit any real-time PCR instrument. QPCR primer and probe design and validation are discussed, and three relative quantitation methods are described: the standard curve method, the efficiency-corrected DeltaCt method, and the comparative cycle time, or DeltaDeltaCt method. In addition, a method is provided for absolute quantification of RNA in unknown samples. RNA standards are subjected to RT-PCR in the same manner as the experimental samples, thus accounting for the reaction efficiencies of both procedures. This protocol describes the production and quantitation of synthetic RNA molecules for real-time and non-real-time RT-PCR applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigro, D.N.
1979-11-01
The report summarizes the DDA activities for the effort performed on the procurement and delivery of eleven Allison GT 404-4 gas turbine engines and five HT740CT and six V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of the engines and transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installation drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE atmore » a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines are to be built with ceramic regenerators. (TFD)« less
[ESC and AHA guidelines 2015 on endocarditis : In competition or synchrony?
Maisch, Bernhard
2016-12-01
In the 2015 guidelines of the European Society of Cardiology (ESC) and the American Heart Association (AHA) on infective endocarditis, the diagnostics are based on the modified Duke criteria. The diagnosis can be confirmed by a combination of micro-organisms demonstrated in culture or in situ, with the detection of valvular lesions or abscess formation by an imaging modality using echocardiography, positron emission tomography computed tomography (PET/CT), cardio-CT or nuclear medical methods. The management should be further improved by an interdisciplinary endocarditis team in a specifically designated reference center. Pharmaceutical treatment is largely unchanged and based on classical antibiotics in monotherapy or as combination therapy but for staphylococcal endocarditis, gentamycin is no longer required. As cardiac surgery is needed in 50 % of the cases during the course of the disease, the urgency for surgery depends on the extent of cardiac insufficiency, the persistence of the pathogen despite antibiotic treatment and on neurological complications.
High-speed upper-airway imaging using full-range optical coherence tomography
NASA Astrophysics Data System (ADS)
Jing, Joseph; Zhang, Jun; Loy, Anthony Chin; Wong, Brian J. F.; Chen, Zhongping
2012-11-01
Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizing radiation, and MRI typically requires sedation of the patient to prevent motion artifacts. Long-range optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images with high resolution and without the use of ionizing radiation. In this paper, we present work on the development of a long-range OCT endoscopic probe with 1.2 mm OD and 20 mm working distance used in conjunction with a modified Fourier domain swept source OCT system to acquire structural and anatomical datasets of the human airway. Imaging from the bottom of the larynx to the end of the nasal cavity is completed within 40 s.
Long-term control of olfactory neuroblastoma in a dog treated with surgery and radiation therapy.
Gumpel, E; Moore, A S; Simpson, D J; Hoffmann, K L; Taylor, D P
2017-07-01
Olfactory neuroblastoma is a rare malignancy of the nasal cavity in dogs that is thought to arise from specialised sensory neuroendocrine olfactory cells derived from the neural crest. An 8-year-old dog was presented for reclusiveness and pacing. On CT and MRI, a contract-enhancing mass was disclosed within the rostral fossa, extending caudally from the cribriform plate into the left nasal sinus. Surgical excision was performed and the diagnosis was histological grade III (Hyams grading scheme) olfactory neuroblastoma. Based on human CT criteria this was high stage (modified Kadish stage C). Surgical excision was incomplete and was followed by curative-intent radiation therapy using a linear accelerator to a total dose of 48 Gy. The dog survived 20 months after diagnosis. Although olfactory neuroblastoma is a rare tumour in dogs, aggressive local therapy may allow for prolonged survival, even when the tumour is advanced. © 2017 Australian Veterinary Association.
Hideghéty, Katalin; Cserháti, Adrienne; Besenyi, Zsuzsanna; Zag, Levente; Gaál, Szilvia; Együd, Zsófia; Mózes, Petra; Szántó, Erika; Csenki, Melinda; Rusz, Orsolya; Varga, Zoltán; Dobi, Ágnes; Maráz, Anikó; Pávics, László; Lengyel, Zsolt
2015-06-01
The purpose of our work is evaluation of the impact of 18FDG-PET/CT on the complex management of locoregionally advanced (T3-4N1-3) head and neck squamous cell cancer (LAHNSC), and on the target definition for 3D conformal (3DCRT) and intensity-modulated radiotherapy (IMRT). 18FDG-PET/CT were performed on 185 patients with LAHNSC prior to radiotherapy/chemoradiation in the treatment position between 2006 and 2011. Prior to it 91 patients received induction chemotherapy (in 20 cases of these, baseline PET/CT was also available). The independently delineated CT-based gross tumor volume (GTVct) and PET/CT based ones (GTVpet) were compared. Impact of PET/CT on the treatment strategy, on tumor response evaluation to ICT, on GTV definition furthermore on overall and disease-specific survival (OS, DSS) was analysed. PET/CT revealed 10 head and neck, 2 lung cancers for 15 patients with carcinoma of unknown primary (CUP) while 3 remained unknown. Second tumors were detected in 8 (4.4%), distant metastasis in 15 (8.2%) cases. The difference between GTVct and GTVpet was significant (p=0.001). In 16 patients (14%) the GTVpet were larger than GTVct due to multifocal manifestations in the laryngo-pharyngeal regions (4 cases) or lymph node metastases (12 cases). In the majority of the cases (82 pts, 72%) PET/CT-based conturing resulted in remarkable decrease in the volume (15-20%: 4 cases, 20-50%: 46 cases, >50%: 32 cases). On the basis of the initial and post-ICT PET/CT comparison in 15/20 patients more than 50% volume reduction and in 6/20 cases complete response were achieved. After an average of 6.4 years of follow-up the OS (median: 18.3±2.6 months) and DSS (median: 25.0±4.0 months) exhibited close correlation (p=0.0001) to the GTVpet. In cases with GTVpet <10 cm3 prior to RT, DSS did not reach the median, the mean is 82.1±6.1 months, while in cases with GTVpet 10-40 cm3 the median of the DSS was 28.8±4.9 months (HR = 3.57; 95% CI: 1.5-8.3), and in those with GTVpet >40 cm3 the median DSS was 8.4±0.96 months (HR= 11.48; 95% CI: 5.3-24.9). Our results suggest that 18FDG-PET/CT plays an important role for patient with LAHNSC, by modifying the treatment concept and improving the target definition for selective RT modalities. Volumetric PET/CT-based assessment of the tumor response after ICT gives valuable contribution to further therapy planning.
Tomographic Neutron Imaging using SIRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregor, Jens; FINNEY, Charles E A; Toops, Todd J
2013-01-01
Neutron imaging is complementary to x-ray imaging in that materials such as water and plastic are highly attenuating while material such as metal is nearly transparent. We showcase tomographic imaging of a diesel particulate filter. Reconstruction is done using a modified version of SIRT called PSIRT. We expand on previous work and introduce Tikhonov regularization. We show that near-optimal relaxation can still be achieved. The algorithmic ideas apply to cone beam x-ray CT and other inverse problems.
Multimodality CT/SPECT Evaluation of Micelle Drug Carriers for Treatment of Breast Tumors
2006-07-01
through the inclusion of a radiolabel. In this study , PEG/PLA or PEG/PCL micelles were modified through the addition of a cRGD targeting ligand and a...macro-initiator and Sn(Oct)2 as a catalyst . Synthesized polymer was then characterized with NMR and gel permeation chromatography (GPC). The resulting...radiolabeled micelle distribution with in vivo animal studies . Reportable Outcomes • Refereed publications - Ai, H., C. Flask, B. Weinberg, X.-T. Shuai
1977-11-01
residual unbaiance. Mass production experience and availability of rotary piston engines -type WANKEL- refer basically to the automobile industry...production air cooled automobile engine in standard form can be ruled out on a specific weight basis. 4. In modified form, as used in many light aircr: Ct...the air cooled automobile engine appears to be a possibility. Availability, lcw initial cost; and good specific fuel consumption could make the unit
Simulation trainer for practicing emergent open thoracotomy procedures.
Hamilton, Allan J; Prescher, Hannes; Biffar, David E; Poston, Robert S
2015-07-01
An emergent open thoracotomy (OT) is a high-risk, low-frequency procedure uniquely suited for simulation training. We developed a cost-effective Cardiothoracic (CT) Surgery trainer and assessed its potential for improving technical and interprofessional skills during an emergent simulated OT. We modified a commercially available mannequin torso with artificial tissue models to create a custom CT Surgery trainer. The trainer's feasibility for simulating emergent OT was tested using a multidisciplinary CT team in three consecutive in situ simulations. Five discretely observable milestones were identified as requisite steps in carrying out an emergent OT; namely (1) diagnosis and declaration of a code situation, (2) arrival of the code cart, (3) arrival of the thoracotomy tray, (4) initiation of the thoracotomy incision, and (5) defibrillation of a simulated heart. The time required for a team to achieve each discrete step was measured by an independent observer over the course of each OT simulation trial and compared. Over the course of the three OT simulation trials conducted in the coronary care unit, there was an average reduction of 29.5% (P < 0.05) in the times required to achieve the five critical milestones. The time required to complete the whole OT procedure improved by 7 min and 31 s from the initial to the final trial-an overall improvement of 40%. In our preliminary evaluation, the CT Surgery trainer appears to be useful for improving team performance during a simulated emergent bedside OT in the coronary care unit. Copyright © 2015 Elsevier Inc. All rights reserved.
Laxative-free CT colonography.
Slater, A; Betts, M; D'Costa, H
2012-08-01
The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as "easy" vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanguineti, Giuseppe; Califano, Joseph; Stafford, Edward
Purpose: To assess the risk of ipsilateral subclinical neck nodal involvement for early T-stage/node-positive oropharyngeal squamous cell carcinoma. Methods and Materials: Patients undergoing multilevel upfront neck dissection (ND) at Johns Hopkins Hospital within the last 10 years for early clinical T-stage (cT1-2) node-positive (cN+) oropharyngeal squamous cell carcinoma were identified. Pathologic involvement of Levels IB-V was determined. For each nodal level, the negative predictive value of imaging results was computed by using sensitivity/specificity data for computed tomography (CT). This was used to calculate 1 - negative predictive value, or the risk that a negative level on CT harbors subclinical disease.more » Results: One hundred three patients met the criteria. Radical ND was performed in 14.6%; modified radical ND, in 70.9%; and selective ND, in 14.6%. Pathologic positivity rates were 9.5%, 91.3%, 40.8%, 18.0%, and 3.3% for Levels IB-V, respectively. Risks of subclinical disease despite negative CT imaging results were calculated as 3.1%, 76.3%, 17.5%, 6.3%, and 1.0% for Levels IB-V, respectively. Conclusions: Levels IB and V are at very low (<5%) risk of involvement, even with ipsilateral to pathologically proven neck disease; this can guide radiation planning. Levels II and III should be included in high-risk volumes regardless of imaging results, and Level IV should be included within the lowest risk volume.« less
MAY, OLIVIA L.; ERISIR, ALEV; HILL, DAVID L.
2008-01-01
The terminal fields of nerves carrying gustatory information to the rat brainstem show a remarkable amount of expansion in the nucleus of the solitary tract (NTS) as a result of early dietary sodium restriction. However, the extent to which these axonal changes represent corresponding changes in synapses is not known. To identify the synaptic characteristics that accompany the terminal field expansion, the greater superficial petrosal (GSP), chorda tympani (CT), and glossopharyngeal (IX) nerves were labeled in rats fed a sodium-restricted diet during pre- and postnatal development. The morphology of these nerve terminals within the NTS region where the terminal fields of all three nerves overlap was evaluated by transmission electron microscopy. Compared to data from control rats, CT axons were the most profoundly affected. The density of CT arbors and synapses quadrupled as a result of the near life-long dietary manipulation. In contrast, axon and synapse densities of GSP and IX nerves were not modified in sodium-restricted rats. Furthermore, compared to controls, CT terminals displayed more instances of contacts with postsynaptic dendritic protrusions and IX terminals synapsed more frequently with dendritic shafts. Thus, dietary sodium restriction throughout pre- and postnatal development had differential effects on the synaptic organization of the three nerves in the NTS. These anatomical changes may underlie the impact of sensory restriction during development on the functional processing of taste information and taste-related behaviors. PMID:18366062
May, Olivia L; Erisir, Alev; Hill, David L
2008-06-01
The terminal fields of nerves carrying gustatory information to the rat brainstem show a remarkable amount of expansion in the nucleus of the solitary tract (NTS) as a result of early dietary sodium restriction. However, the extent to which these axonal changes represent corresponding changes in synapses is not known. To identify the synaptic characteristics that accompany the terminal field expansion, the greater superficial petrosal (GSP), chorda tympani (CT), and glossopharyngeal (IX) nerves were labeled in rats fed a sodium-restricted diet during pre- and postnatal development. The morphology of these nerve terminals within the NTS region where the terminal fields of all three nerves overlap was evaluated by transmission electron microscopy. Compared to data from control rats, CT axons were the most profoundly affected. The density of CT arbors and synapses quadrupled as a result of the near life-long dietary manipulation. In contrast, axon and synapse densities of GSP and IX nerves were not modified in sodium-restricted rats. Furthermore, compared to controls, CT terminals displayed more instances of contacts with postsynaptic dendritic protrusions and IX terminals synapsed more frequently with dendritic shafts. Thus, dietary sodium restriction throughout pre- and postnatal development had differential effects on the synaptic organization of the three nerves in the NTS. These anatomical changes may underlie the impact of sensory restriction during development on the functional processing of taste information and taste-related behaviors.
Eidelman, Polina; Talbot, Lisa; Ivers, Hans; Bélanger, Lynda; Morin, Charles M; Harvey, Allison G
2016-01-01
As part of a larger randomized controlled trial, 188 participants were randomized to behavior therapy (BT), cognitive therapy (CT), or cognitive-behavioral therapy (CBT) for insomnia. The aims of this study were threefold: (a) to determine whether change in dysfunctional beliefs about sleep was related to change in sleep, insomnia symptoms, and impairment following treatment; (b) to determine whether BT, CT, and CBT differ in their effects on dysfunctional beliefs; and (c) to determine whether the treatments differ in their effects on particular kinds of dysfunctional beliefs. Beliefs, sleep, insomnia symptoms, and sleep-related psychosocial impairment were assessed at pretreatment, posttreatment, and 6- and 12-month follow-up. Greater change in dysfunctional beliefs occurring over the course of BT, CT, or CBT was associated with greater improvement in insomnia symptoms and impairment at posttreatment and both follow-ups. All groups experienced a significant decrease in dysfunctional beliefs during treatment, which were sustained through 6- and 12-month follow-up. Compared with the BT group, a greater proportion of participants in the CT and/or CBT groups endorsed dysfunctional beliefs below a level considered clinically significant at posttreatment and 12-month follow-up. The results demonstrate the importance of targeting dysfunctional beliefs in insomnia treatment, suggest that beliefs may be significantly modified with BT alone, and indicate that cognitive interventions may be particularly powerful in enhancing belief change. Copyright © 2016. Published by Elsevier Ltd.
Farolfi, Andrea; Ceci, Francesco; Castellucci, Paolo; Graziani, Tiziano; Siepe, Giambattista; Lambertini, Alessandro; Schiavina, Riccardo; Lodi, Filippo; Morganti, Alessio G; Fanti, Stefano
2018-06-15
The primary aim of this retrospective, single-centre analysis was to assess the performance of 68 Ga-PSMA-11 PET/CT in prostate cancer (PCa) patients in early PSA failure after radical prostatectomy (RP). The secondary aim was to assess the potential impact of 68 Ga-PSMA-11 PET/CT on treatment strategy. 68 Ga-PSMA-11 PET/CT is performed in our institution within an investigational new drug (IND) trial in PCa patients with biochemical recurrence (BCR). The records of all patients enrolled between March 2016 and July 2017 were evaluated. These records were retrospectively analysed according to the following inclusion criteria: (a) RP as primary therapy, (b) proven BCR, ©) PSA levels in the range 0.2-0.5 ng/ml at the time of the 68 Ga-PSMA-11 PET/CT investigation, and (d) no salvage radiotherapy (S-RT) performed after recurrence. The performance of 68 Ga-PSMA-11 PET/CT was evaluated in terms of detection rate on a per-patient and a per-region basis (local vs. distant lesions). We further performed an intention-to-treat (ITT) analysis. The patient cohort was grouped into three subpopulations, blinded to the 68 Ga-PSMA-11 PET/CT results, according to the patients' characteristics and different patterns of treatment: (1) S-RT (with or without systemic treatment), (2) stereotactic body radiotherapy (SBRT) (with or without systemic treatment), and (3) systemic treatment. The treatment strategy was re-evaluated for each patient taking into consideration the 68 Ga-PSMA-11 PET/CT images. We enrolled 119 PCa patients (mean age 66 years, range 44-78 years) with a mean PSA level at the time of 68 Ga-PSMA-11 PET/CT of 0.34 ng/ml (median 0.32 ng/ml, SD ±0.09, range 0.20-0.50 ng/ml). 68 Ga-PSMA-1 1 PET/CT was positive in 41 of the 119 patients, resulting in an overall detection rate of 34.4%. 68 Ga-PSMA-11 uptake was observed in the prostate bed (3 patients, 2.5%), in the pelvic lymph nodes (21, 17.6%), in the retroperitoneal lymph nodes (4, 3.4%) and in the skeleton (21, 17.6%). Regarding ITT, 81 patients (68.1%) were considered possible candidates for S-RT only in the prostate bed and none of the patients (0%) for SBRT. According to the 68 Ga-PSMA-11 PET/CT results, the intended treatment was changed in 36 patients (30.2%). According to the PET/CT results, S-RT was recommended in 70 patients (58.8%), only to the prostate bed in 58 (48.7%) and SBRT in 29 (24.4%). The intended RT planning was modified in 36 (87.8%) of 41 patients with a positive 68 Ga-PSMA-11 PET/CT result. In our patient series with PSA levels <0.5 ng/ml, 68 Ga-PSMA-11 PET/CT had a detection rate of 34.4%. In the ITT analysis, 30.2% of patients had a change in the intended treatment. These data support the hypothesis that 68 Ga-PSMA-11 PET/CT is a useful procedure in the management of PCa patients showing early recurrence after RP, and should be implemented in routine clinical practice.
3D conformal radiation therapy for palliative treatment of canine nasal tumors.
Buchholz, Julia; Hagen, Regine; Leo, Chiara; Ebling, Alessia; Roos, Malgorzata; Kaser-Hotz, Barbara; Bley, Carla Rohrer
2009-01-01
We evaluated the response of 38 dogs treated with a coarsely fractionated, palliative radiation protocol based on CT-based 3D treatment planning. Dogs with histologically confirmed malignant nasal tumors were studied. Treatment prescriptions consisted of 3-4 x 8 Gy, 4-5 x 6 Gy, or 10 x 3 Gy fractions. Selected patient and tumor factors were evaluated for an effect on outcome. Resolution of clinical signs was reported after irradiation in all dogs. Acute toxicities were mild and short lived. Thirty-seven of 38 dogs died or were euthanized due to tumor-related disease. Overall median progression-free interval (PFI) was 10 months. Tumor stage affected response, with modified stage 1 patients having a median PFI 21.3 months vs. a median PFI of 8.5 months for modified stage 2 patients (P = 0.0006). Modified stage was the only factor significantly related to outcome. Based on these findings, a palliative radiation prescription based on computerized treatment planning may be justified in some canine nasal tumor patients.
Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jost, Gregor; Mensing, Tristan; Golfier, Sven
2009-06-15
Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detectionmore » system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Zhang, J; Hu, Q
2014-06-01
Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with intervalmore » of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.« less
Yeo, L L L; Paliwal, P; Teoh, H L; Seet, R C; Chan, B P; Ting, E; Venketasubramanian, N; Leow, W K; Wakerley, B; Kusama, Y; Rathakrishnan, R; Sharma, V K
2015-02-01
Intracranial collaterals influence the prognosis of patients treated with intravenous tissue plasminogen activator in acute anterior circulation ischemic stroke. We compared the methods of scoring collaterals on pre-tPA brain CT angiography for predicting functional outcomes in acute anterior circulation ischemic stroke. Two hundred consecutive patients with acute anterior circulation ischemic stroke treated with IV-tPA during 2010-2012 were included. Two independent neuroradiologists evaluated intracranial collaterals by using the Miteff system, Maas system, the modified Tan scale, and the Alberta Stroke Program Early CT Score 20-point methodology. Good and extremely poor outcomes at 3 months were defined by modified Rankin Scale scores of 0-1 and 5-6 points, respectively. Factors associated with good outcome on univariable analysis were younger age, female sex, hypertension, diabetes mellitus, atrial fibrillation, small infarct core (ASPECTS ≥8), vessel recanalization, lower pre-tPA NIHSS scores, and good collaterals according to Tan methodology, ASPECTS methodology, and Miteff methodology. On multivariable logistic regression, only lower NIHSS scores (OR, 1.186 per point; 95% CI, 1.079-1.302; P = .001), recanalization (OR, 5.599; 95% CI, 1.560-20.010; P = .008), and good collaterals by the Miteff method (OR, 3.341; 95% CI, 1.203-5.099; P = .014) were independent predictors of good outcome. Poor collaterals by the Miteff system (OR, 2.592; 95% CI, 1.113-6.038; P = .027), Maas system (OR, 2.580; 95% CI, 1.075-6.187; P = .034), and ASPECTS method ≤5 points (OR, 2.685; 95% CI, 1.156-6.237; P = .022) were independent predictors of extremely poor outcomes. Only the Miteff scoring system for intracranial collaterals is reliable for predicting favorable outcome in thrombolyzed acute anterior circulation ischemic stroke. However, poor outcomes can be predicted by most of the existing methods of scoring intracranial collaterals. © 2015 by American Journal of Neuroradiology.
SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamima, T; Takahashi, R; Sato, Y
2015-06-15
Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conductedmore » in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.« less
Price, Dominique N; McBride, Amber A; Anton, Martina; Kusewitt, Donna F; Norenberg, Jeffrey P; MacKenzie, Debra A; Thompson, Todd A; Muttil, Pavan
2016-01-01
Lung cancer has the highest mortality rate of any tissue-specific cancer in both men and women. Research continues to investigate novel drugs and therapies to mitigate poor treatment efficacy, but the lack of a good descriptive lung cancer animal model for preclinical drug evaluation remains an obstacle. Here we describe the development of an orthotopic lung cancer animal model which utilizes the human sodium iodide symporter gene (hNIS; SLC5A5) as an imaging reporter gene for the purpose of non-invasive, longitudinal tumor quantification. hNIS is a glycoprotein that naturally transports iodide (I-) into thyroid cells and has the ability to symport the radiotracer 99mTc-pertechnetate (99mTcO4-). A549 lung adenocarcinoma cells were genetically modified with plasmid or lentiviral vectors to express hNIS. Modified cells were implanted into athymic nude mice to develop two tumor models: a subcutaneous and an orthotopic xenograft tumor model. Tumor progression was longitudinally imaged using SPECT/CT and quantified by SPECT voxel analysis. hNIS expression in lung tumors was analyzed by quantitative real-time PCR. Additionally, hematoxylin and eosin staining and visual inspection of pulmonary tumors was performed. We observed that lentiviral transduction provided enhanced and stable hNIS expression in A549 cells. Furthermore, 99mTcO4- uptake and accumulation was observed within lung tumors allowing for imaging and quantification of tumor mass at two-time points. This study illustrates the development of an orthotopic lung cancer model that can be longitudinally imaged throughout the experimental timeline thus avoiding inter-animal variability and leading to a reduction in total animal numbers. Furthermore, our orthotopic lung cancer animal model is clinically relevant and the genetic modification of cells for SPECT/CT imaging can be translated to other tissue-specific tumor animal models.
Anton, Martina; Kusewitt, Donna F.; Norenberg, Jeffrey P.; MacKenzie, Debra A.; Thompson, Todd A.; Muttil, Pavan
2016-01-01
Lung cancer has the highest mortality rate of any tissue-specific cancer in both men and women. Research continues to investigate novel drugs and therapies to mitigate poor treatment efficacy, but the lack of a good descriptive lung cancer animal model for preclinical drug evaluation remains an obstacle. Here we describe the development of an orthotopic lung cancer animal model which utilizes the human sodium iodide symporter gene (hNIS; SLC5A5) as an imaging reporter gene for the purpose of non-invasive, longitudinal tumor quantification. hNIS is a glycoprotein that naturally transports iodide (I-) into thyroid cells and has the ability to symport the radiotracer 99mTc-pertechnetate (99mTcO4-). A549 lung adenocarcinoma cells were genetically modified with plasmid or lentiviral vectors to express hNIS. Modified cells were implanted into athymic nude mice to develop two tumor models: a subcutaneous and an orthotopic xenograft tumor model. Tumor progression was longitudinally imaged using SPECT/CT and quantified by SPECT voxel analysis. hNIS expression in lung tumors was analyzed by quantitative real-time PCR. Additionally, hematoxylin and eosin staining and visual inspection of pulmonary tumors was performed. We observed that lentiviral transduction provided enhanced and stable hNIS expression in A549 cells. Furthermore, 99mTcO4- uptake and accumulation was observed within lung tumors allowing for imaging and quantification of tumor mass at two-time points. This study illustrates the development of an orthotopic lung cancer model that can be longitudinally imaged throughout the experimental timeline thus avoiding inter-animal variability and leading to a reduction in total animal numbers. Furthermore, our orthotopic lung cancer animal model is clinically relevant and the genetic modification of cells for SPECT/CT imaging can be translated to other tissue-specific tumor animal models. PMID:28036366
Ash, Samuel Y; Harmouche, Rola; Ross, James C; Diaz, Alejandro A; Rahaghi, Farbod N; Sanchez-Ferrero, Gonzalo Vegas; Putman, Rachel K; Hunninghake, Gary M; Onieva, Jorge Onieva; Martinez, Fernando J; Choi, Augustine M; Bowler, Russell P; Lynch, David A; Hatabu, Hiroto; Bhatt, Surya P; Dransfield, Mark T; Wells, J Michael; Rosas, Ivan O; San Jose Estepar, Raul; Washko, George R
2018-06-05
Purpose To determine if interstitial features at chest CT enhance the effect of emphysema on clinical disease severity in smokers without clinical pulmonary fibrosis. Materials and Methods In this retrospective cohort study, an objective CT analysis tool was used to measure interstitial features (reticular changes, honeycombing, centrilobular nodules, linear scar, nodular changes, subpleural lines, and ground-glass opacities) and emphysema in 8266 participants in a study of chronic obstructive pulmonary disease (COPD) called COPDGene (recruited between October 2006 and January 2011). Additive differences in patients with emphysema with interstitial features and in those without interstitial features were analyzed by using t tests, multivariable linear regression, and Kaplan-Meier analysis. Multivariable linear and Cox regression were used to determine if interstitial features modified the effect of continuously measured emphysema on clinical measures of disease severity and mortality. Results Compared with individuals with emphysema alone, those with emphysema and interstitial features had a higher percentage predicted forced expiratory volume in 1 second (absolute difference, 6.4%; P < .001), a lower percentage predicted diffusing capacity of lung for carbon monoxide (DLCO) (absolute difference, 7.4%; P = .034), a 0.019 higher right ventricular-to-left ventricular (RVLV) volume ratio (P = .029), a 43.2-m shorter 6-minute walk distance (6MWD) (P < .001), a 5.9-point higher St George's Respiratory Questionnaire (SGRQ) score (P < .001), and 82% higher mortality (P < .001). In addition, interstitial features modified the effect of emphysema on percentage predicted DLCO, RVLV volume ratio, 6WMD, SGRQ score, and mortality (P for interaction < .05 for all). Conclusion In smokers, the combined presence of interstitial features and emphysema was associated with worse clinical disease severity and higher mortality than was emphysema alone. In addition, interstitial features enhanced the deleterious effects of emphysema on clinical disease severity and mortality. © RSNA, 2018 Online supplemental material is available for this article.
Kim, Eun Young; Kim, Nambeom; Kim, Young Saing; Seo, Ja-Young; Park, Inkeun; Ahn, Hee Kyung; Jeong, Yu Mi; Kim, Jeong Ho
2016-01-01
Advanced lung cancer inflammation index (ALI, body mass index [BMI] x serum albumin/neutrophil-lymphocyte ratio [NLR]) has been shown to predict overall survival (OS) in small cell lung cancer (SCLC). CT enables skeletal muscle to be quantified, whereas BMI cannot accurately reflect body composition. The purpose was to evaluate prognostic value of modified ALI (mALI) using CT-determined L3 muscle index (L3MI, muscle area at L3/height2) beyond original ALI. L3MIs were calculated using the CT images of 186 consecutive patients with SCLC taken at diagnosis, and mALI was defined as L3MI x serum albumin/NLR. Using chi-squared test determined maximum cut-offs for low ALI and low mALI, the prognostic values of low ALI and low mALI were tested using Kaplan-Meier method and Cox proportional hazards analysis. Finally, deviance statistics was used to test whether the goodness of fit of the prognostic model is improved by adding mALI as an extra variable. Patients with low ALI (cut-off, 31.1, n = 94) had shorter OS than patients with high ALI (median, 6.8 months vs. 15.8 months; p < 0.001), and patients with low mALI (cut-off 67.7, n = 94) had shorter OS than patients with high mALI (median, 6.8 months vs. 16.5 months; p < 0.001). There was no significant difference in estimates of median survival time between low ALI and low mALI (z = 0.000, p = 1.000) and between high ALI and high mALI (z = 0.330, p = 0.740). Multivariable analysis showed that low ALI was an independent prognostic factor for shorter OS (HR, 1.67, p = 0.004), along with advanced age (HR, 1.49, p = 0.045), extensive disease (HR, 2.27, p < 0.001), supportive care only (HR, 7.86, p < 0.001), and elevated LDH (HR, 1.45, p = 0.037). Furthermore, goodness of fit of this prognostic model was not significantly increased by adding mALI as an extra variable (LR difference = 2.220, p = 0.136). The present study confirms mALI using CT-determined L3MI has no additional prognostic value beyond original ALI using BMI. ALI is a simple and useful prognostic indicator in SCLC.
Kamel, Azza M; Ebid, Gamal T A; Moussa, Heba S
2015-08-01
N-Acetyltransferases (NAT) have been known to modify the risk to a variety of solid tumors. However, the role of NAT2 polymorphism in risk susceptibility to childhood acute lymphoblastic leukemia (ALL) is still not well known. We performed a case-control study to determine if the common NAT2 polymorphisms play a role in altering susceptibility to pediatric ALL. DNA of 92 pediatric ALL patients and 312 healthy controls was analyzed for the NAT2 polymorphisms using the PCR-RFLP method. The wild-type NAT2*4 was encountered in 8.6 % of patients versus 11.8 % of controls (P = 0.23). The rapid acetylators NAT2*12 803A>G, AG, GG, and AG/GG were overrepresented in controls (P = 0.0001; odds ratio (OR) 0.22, 0.19, and 0.21 respectively). NAT2*5D 341T>C and NAT2*11A 481C>T were of comparable frequencies. For their combination, NAT2*5A, a slow acetylator, both TCTT and CCCT were overrepresented in patients (P < 0.001; OR 15.8 and 17.9 respectively). NAT2*5B (803A>G, 341T>C, 481C>T) was overrepresented in controls (P < 0.001; OR 0.12). Apparently, 803A>G ameliorated the combined effect of 341T>C and 481C>T. A similar effect was obtained with NAT2*5C (341T>A, 803A>G) (P < 0.0001; OR 0.11). For slow acetylator NAT2*7A 857G>A, GA and GA/AA were overrepresented in patients (P = 0.009 and 0.01; OR 2.74 and 2.72 respectively). NAT2*13 282C>T, NAT2*6B 590G>A, and NAT2*14A 191G>A were of comparable frequencies. NAT2 282C>A in combination with NAT2 857G>A (NAT2*7B) showed a synergistic effect in patients versus controls (P < 0.0001; OR 3.51). In conclusion, NAT2 gene polymorphism(s) with slow acetylator phenotype is generally associated with the risk of development of ALL in children.
A model-based scatter artifacts correction for cone beam CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Wei; Zhu, Jun; Wang, Luyao
2016-04-15
Purpose: Due to the increased axial coverage of multislice computed tomography (CT) and the introduction of flat detectors, the size of x-ray illumination fields has grown dramatically, causing an increase in scatter radiation. For CT imaging, scatter is a significant issue that introduces shading artifact, streaks, as well as reduced contrast and Hounsfield Units (HU) accuracy. The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. Methods: The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain ormore » projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Scatter correction in both projection domain and image domain was conducted and the influences of segmentation method, mismatched attenuation coefficients, and spectrum model as well as parameter selection were also investigated. Results: Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four-components segmentation yields the best results, while the results of three-components segmentation are still acceptable. The parameters (iteration number K and weight β) affect the accuracy of the scatter correction and the results get improved as K and β increase. It was found that variations in attenuation coefficient accuracies only slightly impact the performance of the proposed processing. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from −21.8 to −0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images is greatly improved after correction. Conclusions: The software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow (i.e., no extra scan/measurement data are needed) or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.« less
An Experimental Study of the Dynamics of an Unsteady Turbulent Boundary Layer.
1982-12-01
honeycomb combination into the screen box. The screen box is made of plexiglas, and the screens are made of stainless steel wire (24 gauge, 70% porosity...port plug was modified to accommodate at its cen- ter a stainless steel stem with a disk on the end toward the inside of the tunnel. The stem is spring...necessay and Identify by block nomber) * turbulent boundary layers fluid dynamics free stream velocity A B r R CT si royy.rs ebb it ,imseesa nd ideiiit
NASA Astrophysics Data System (ADS)
Yi, Zhigao; Lu, Wei; Liu, Hongrong; Zeng, Songjun
2014-12-01
Polyacrylic acid (PAA) modified NaYF4:Gd/Yb/Er upconversion nanorods (denoted as PAA-UCNRs) are demonstrated for tri-modal upconversion (UC) optical, computed X-ray tomography (CT), and magnetic resonance imaging (MRI). The hydrophilic PAA-UCNRs were obtained from hydrophobic oleic acid (OA) capped UCNRs (denoted as OA-UCNRs) using a ligand exchange method. The as-prepared UCNRs with a hexagonal phase structure present high monodispersity. These PAA-UCNRs are successfully used as ideal probes for in vivo UC luminescence bioimaging and synergistic X-ray and UC bioimaging. Moreover, X-ray CT imaging reveals that PAA-UCNRs can act as contrast agents for improved detection of the liver and spleen. In addition, a significant signal enhancement in the liver is observed in in vivo MRI, indicating that PAA-UCNRs are ideal T1-weighted MRI agents. More importantly, in vivo long-term tracking based on these PAA-UCNRs in the live mice and the corresponding ex vivo bioimaging of isolated organs also verify the translocation of PAA-UCNRs from the liver to the spleen, and the observed intense UC signals from the feces reveal the biliary excretion mechanism of these UCNRs. These findings contribute to understanding of the translocation and potential route for excretion of PAA-UCNRs, which can provide an important guide for the diagnosis and detection of diseases based on these UCNRs.Polyacrylic acid (PAA) modified NaYF4:Gd/Yb/Er upconversion nanorods (denoted as PAA-UCNRs) are demonstrated for tri-modal upconversion (UC) optical, computed X-ray tomography (CT), and magnetic resonance imaging (MRI). The hydrophilic PAA-UCNRs were obtained from hydrophobic oleic acid (OA) capped UCNRs (denoted as OA-UCNRs) using a ligand exchange method. The as-prepared UCNRs with a hexagonal phase structure present high monodispersity. These PAA-UCNRs are successfully used as ideal probes for in vivo UC luminescence bioimaging and synergistic X-ray and UC bioimaging. Moreover, X-ray CT imaging reveals that PAA-UCNRs can act as contrast agents for improved detection of the liver and spleen. In addition, a significant signal enhancement in the liver is observed in in vivo MRI, indicating that PAA-UCNRs are ideal T1-weighted MRI agents. More importantly, in vivo long-term tracking based on these PAA-UCNRs in the live mice and the corresponding ex vivo bioimaging of isolated organs also verify the translocation of PAA-UCNRs from the liver to the spleen, and the observed intense UC signals from the feces reveal the biliary excretion mechanism of these UCNRs. These findings contribute to understanding of the translocation and potential route for excretion of PAA-UCNRs, which can provide an important guide for the diagnosis and detection of diseases based on these UCNRs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05161k
Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira
2016-01-01
Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776
Diagnosis and management of Crohn's disease.
Wilkins, Thad; Jarvis, Kathryn; Patel, Jigneshkumar
2011-12-15
Crohn's disease is a chronic inflammatory condition affecting the gastrointestinal tract at any point from the mouth to the rectum. Patients may experience diarrhea, abdominal pain, fever, weight loss, abdominal masses, and anemia. Extraintestinal manifestations of Crohn's disease include osteoporosis, inflammatory arthropathies, scleritis, nephrolithiasis, cholelithiasis, and erythema nodosum. Acute phase reactants, such as C-reactive protein level and erythrocyte sedimentation rate, are often increased with inflammation and may correlate with disease activity. Levels of vitamin B12, folate, albumin, prealbumin, and vitamin D can help assess nutritional status. Colonoscopy with ileoscopy, capsule endoscopy, computed tomography enterography, and small bowel follow-through are often used to diagnose Crohn's disease. Ultrasonography, computed axial tomography, scintigraphy, and magnetic resonance imaging can assess for extraintestinal manifestations or complications (e.g., abscess, perforation). Mesalamine products are often used for the medical management of mild to moderate colonic Crohn's disease. Antibiotics (e.g., metronidazole, fluoroquinolones) are often used for treatment. Patients with moderate to severe Crohn's disease are treated with corticosteroids, azathioprine, 6-mercaptopurine, or anti-tumor necrosis factor agents (e.g., infliximab, adalimumab). Severe disease may require emergent hospitalization and a multidisciplinary approach with a family physician, gastroenterologist, and surgeon.
Update on imaging of Peutz-Jeghers syndrome
Tomas, Catherine; Soyer, Philippe; Dohan, Anthony; Dray, Xavier; Boudiaf, Mourad; Hoeffel, Christine
2014-01-01
Peutz-Jeghers syndrome (PJS) is a rare, autosomal dominant disease linked to a mutation of the STK 11 gene and is characterized by the development of benign hamartomatous polyps in the gastrointestinal tract in association with a hyperpigmentation on the lips and oral mucosa. Patients affected by PJS have an increased risk of developing gastrointestinal and extra-digestive cancer. Malignancy most commonly occurs in the small-bowel. Extra-intestinal malignancies are mostly breast cancer and gynecological tumors or, to a lesser extent, pancreatic cancer. These polyps are also at risk of acute gastrointestinal bleeding, intussusception and bowel obstruction. Recent guidelines recommend regular small-bowel surveillance to reduce these risks associated with PJS. Small-bowel surveillance allows for the detection of large polyps and the further referral of selected PJS patients for endoscopic enteroscopy or surgery. Video capsule endoscopy, double balloon pushed enteroscopy, multidetector computed tomography and magnetic resonance enteroclysis or enterography, all of which are relatively new techniques, have an important role in the management of patients suffering from PJS. This review illustrates the pathological, clinical and imaging features of small-bowel abnormalities as well as the role and performance of the most recent imaging modalities for the detection and follow-up of PJS patients. PMID:25152588
Pandey, Sagar; Fan, Miao; Xu, Zhe; Yan, Chaogui; Zhu, Junfeng; Li, Xiuhong
2016-10-01
Meckel diverticulum (MD) is the most common congenital abnormality of gastrointestinal tract. Tough believed to occur in 2% of population, most of them remain veiled because majority are clinically asymptomatic and remain obscure in radiological examination. A 26-year-old male with episodic black colored stool since last 10 years. Tough symptomatic, diagnosis of pathological lesion, and the bleeding site could not be established with any of the sophisticated diagnostic technique. After 10 years, it was finally diagnosed as MD with careful observation of bowel loops on computed tomography enterography (CTE) where remnant of vitelline vessel and hyper-enhancing nodule are seen along the wall of diverticular loop. The patient underwent robot assisted laparoscopic surgery with excision of diverticular loop. To the best of our knowledge, this robot-assistant Meckel diverculectomy is probably the first reported surgical procedure in PubMed. Follow-up for 3 month showed no complication or recurrence. Every case is unique and we must be aware and remain alert in tracing the possible morphological variation of the case. Here, we present one unique but rare feature of MD, which helped us in making diagnosis.
Sethi, Gaurav; Saini, B S
2015-12-01
This paper presents an abdomen disease diagnostic system based on the flexi-scale curvelet transform, which uses different optimal scales for extracting features from computed tomography (CT) images. To optimize the scale of the flexi-scale curvelet transform, we propose an improved genetic algorithm. The conventional genetic algorithm assumes that fit parents will likely produce the healthiest offspring that leads to the least fit parents accumulating at the bottom of the population, reducing the fitness of subsequent populations and delaying the optimal solution search. In our improved genetic algorithm, combining the chromosomes of a low-fitness and a high-fitness individual increases the probability of producing high-fitness offspring. Thereby, all of the least fit parent chromosomes are combined with high fit parent to produce offspring for the next population. In this way, the leftover weak chromosomes cannot damage the fitness of subsequent populations. To further facilitate the search for the optimal solution, our improved genetic algorithm adopts modified elitism. The proposed method was applied to 120 CT abdominal images; 30 images each of normal subjects, cysts, tumors and stones. The features extracted by the flexi-scale curvelet transform were more discriminative than conventional methods, demonstrating the potential of our method as a diagnostic tool for abdomen diseases.
Bodon, Gergely; Grimm, Andras; Hirt, Bernhard; Seifarth, Harald; Barsa, Pavel
2016-10-01
To present a method of posterior arch and lateral mass screw (PALMS) insertion and to prove its feasibility. Four formalin-fixed specimens and 40 macerated atlas vertebras were used to describe the relevant anatomy. The height of the posterior arch was measured on 42 consecutive patients using standard CT of the cervical spine. The operative technique and the special CT reconstructions used for preoperative planning are described. Eight patients underwent posterior fixation using this technique. We described the relevant anatomy and important anatomical landmarks of the posterior arch of the atlas. PALMS placement was modified according to these anatomical findings. Fifteen PALMSs were placed in eight patients using this technique without vascular or neural injury. It is feasible to place PALMS using the described technique. CT angiography is of crucial importance for preoperative planning using the described special reconstructions. The arch posterior to the lateral mass (APLM) is defined as the bone stock situated posterior to the lateral mass, respecting its convergence. The ideal entry point for a PALMS is on the APLM above the center of the converging lateral mass. A complete or incomplete ponticulus posticus and a retrotransverse foramen or groove can be used as an accessory landmark to refine the entry point.
NASA Astrophysics Data System (ADS)
Wu, T. Y.; Lin, S. F.
2013-10-01
Automatic suspected lesion extraction is an important application in computer-aided diagnosis (CAD). In this paper, we propose a method to automatically extract the suspected parotid regions for clinical evaluation in head and neck CT images. The suspected lesion tissues in low contrast tissue regions can be localized with feature-based segmentation (FBS) based on local texture features, and can be delineated with accuracy by modified active contour models (ACM). At first, stationary wavelet transform (SWT) is introduced. The derived wavelet coefficients are applied to derive the local features for FBS, and to generate enhanced energy maps for ACM computation. Geometric shape features (GSFs) are proposed to analyze each soft tissue region segmented by FBS; the regions with higher similarity GSFs with the lesions are extracted and the information is also applied as the initial conditions for fine delineation computation. Consequently, the suspected lesions can be automatically localized and accurately delineated for aiding clinical diagnosis. The performance of the proposed method is evaluated by comparing with the results outlined by clinical experts. The experiments on 20 pathological CT data sets show that the true-positive (TP) rate on recognizing parotid lesions is about 94%, and the dimension accuracy of delineation results can also approach over 93%.
Automated brain computed tomographic densitometry of early ischemic changes in acute stroke
Stoel, Berend C.; Marquering, Henk A.; Staring, Marius; Beenen, Ludo F.; Slump, Cornelis H.; Roos, Yvo B.; Majoie, Charles B.
2015-01-01
Abstract. The Alberta Stroke Program Early CT score (ASPECTS) scoring method is frequently used for quantifying early ischemic changes (EICs) in patients with acute ischemic stroke in clinical studies. Varying interobserver agreement has been reported, however, with limited agreement. Therefore, our goal was to develop and evaluate an automated brain densitometric method. It divides CT scans of the brain into ASPECTS regions using atlas-based segmentation. EICs are quantified by comparing the brain density between contralateral sides. This method was optimized and validated using CT data from 10 and 63 patients, respectively. The automated method was validated against manual ASPECTS, stroke severity at baseline and clinical outcome after 7 to 10 days (NIH Stroke Scale, NIHSS) and 3 months (modified Rankin Scale). Manual and automated ASPECTS showed similar and statistically significant correlations with baseline NIHSS (R=−0.399 and −0.277, respectively) and with follow-up mRS (R=−0.256 and −0.272), except for the follow-up NIHSS. Agreement between automated and consensus ASPECTS reading was similar to the interobserver agreement of manual ASPECTS (differences <1 point in 73% of cases). The automated ASPECTS method could, therefore, be used as a supplementary tool to assist manual scoring. PMID:26158082
Possibilities of CT Scanning as Analysis Method in Laser Additive Manufacturing
NASA Astrophysics Data System (ADS)
Karme, Aleksis; Kallonen, Aki; Matilainen, Ville-Pekka; Piili, Heidi; Salminen, Antti
Laser additive manufacturing is an established and constantly developing technique. Structural assessment should be a key component to ensure directed evolution towards higher level of manufacturing. The macroscopic properties of metallic structures are determined by their internal microscopic features, which are difficult to assess using conventional surface measuring methodologies. X-ray microtomography (CT) is a promising technique for three-dimensional non-destructive probing of internal composition and build of various materials. Aim of this study is to define the possibilities of using CT scanning as quality control method in LAM fabricated parts. Since the parts fabricated with LAM are very often used in high quality and accuracy demanding applications in various industries such as medical and aerospace, it is important to be able to define the accuracy of the build parts. The tubular stainless steel test specimens were 3D modelled, manufactured with a modified research AM equipment and imaged after manufacturing with a high-power, high-resolution CT scanner. 3D properties, such as surface texture and the amount and distribution of internal pores, were also evaluated in this study. Surface roughness was higher on the interior wall of the tube, and deviation from the model was systematically directed towards the central axis. Pore distribution showed clear organization and divided into two populations; one following the polygon model seams along both rims, and the other being associated with the concentric and equidistant movement path of the laser. Assessment of samples can enhance the fabrication by guiding the improvement of both modelling and manufacturing process.
Gay, Hiram A.; Barthold, H. Joseph; O’Meara, Elizabeth; Bosch, Walter R.; El Naqa, Issam; Al-Lozi, Rawan; Rosenthal, Seth A.; Lawton, Colleen; Lee, W. Robert; Sandler, Howard; Zietman, Anthony; Myerson, Robert; Dawson, Laura A.; Willett, Christopher; Kachnic, Lisa A.; Jhingran, Anuja; Portelance, Lorraine; Ryu, Janice; Small, William; Gaffney, David; Viswanathan, Akila N.; Michalski, Jeff M.
2012-01-01
Purpose To define a male and female pelvic normal tissue contouring atlas for Radiation Therapy Oncology Group (RTOG) trials. Methods and Materials One male pelvis computed tomography (CT) data set and one female pelvis CT data set were shared via the Image-Guided Therapy QA Center. A total of 16 radiation oncologists participated. The following organs at risk were contoured in both CT sets: anus, anorectum, rectum (gastrointestinal and genitourinary definitions), bowel NOS (not otherwise specified), small bowel, large bowel, and proximal femurs. The following were contoured in the male set only: bladder, prostate, seminal vesicles, and penile bulb. The following were contoured in the female set only: uterus, cervix, and ovaries. A computer program used the binomial distribution to generate 95% group consensus contours. These contours and definitions were then reviewed by the group and modified. Results The panel achieved consensus definitions for pelvic normal tissue contouring in RTOG trials with these standardized names: Rectum, AnoRectum, SmallBowel, Colon, BowelBag, Bladder, UteroCervix, Adnexa_R, Adnexa_L, Prostate, SeminalVesc, PenileBulb, Femur_R, and Femur_L. Two additional normal structures whose purpose is to serve as targets in anal and rectal cancer were defined: AnoRectumSig and Mesorectum. Detailed target volume contouring guidelines and images are discussed. Conclusions Consensus guidelines for pelvic normal tissue contouring were reached and are available as a CT image atlas on the RTOG Web site. This will allow uniformity in defining normal tissues for clinical trials delivering pelvic radiation and will facilitate future normal tissue complication research. PMID:22483697
Slater, A; Betts, M; D'Costa, H
2012-01-01
Objectives The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. Methods Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin® (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. Results 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as “easy” vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). Conclusion Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives. PMID:22167512
Pre and post PET-CT impact on oesophageal cancer management: a retrospective analysis.
NASA Astrophysics Data System (ADS)
Azmi, NA; Razak, HRA; Vinjamuri, S.
2017-05-01
Assessment of the retrospective cancer incidence, prevalence and crude survival rates of oesophageal cancer to allow comparison between pre and post PET-CT introduction are part of 4 phase cost effectiveness research. It will provide baseline data for to assess PET or PET-CT cost effective potential for staging. A total of 849 patient’s data received from NWCIS databases with various stages of oesophageal cancer between 2001 and 2008. The fundamental activities are retrospective analysis of patient data. In most cases where appropriate, results are presented with 95 percent confidence intervals (CI). Variances between patient groups and variables are assessed using chi-square test. In cases where it deems vital, multiple logistic regression are used to modify for potential confounder such as age and sex. All p-values are two-sided and any value lower than 0.05 were considered to suggest a statistically significant result. Retrospective analysis were categorised into two categories, patients from 2001-2003 considered as pre PET and post PET for 2004-2008. This categorisation allows better comparison of patients’ survival trend to be made between both groups. Rates are presented in percentages and being grouped by tumour characteristics and other variables associated with demographic profile, diagnosis, staging and treatment. Results allowed comparison of oesophageal cancer trends between the pre and post PET-CT introduction such as changes in incidence rate or changes in survival. These data were used to normalise the decision tree model so that cost-effectiveness analysis can be performed across the whole population.
Prell, D; Kalender, W A; Kyriakou, Y
2010-12-01
The purpose of this study was to develop, implement and evaluate a dedicated metal artefact reduction (MAR) method for flat-detector CT (FDCT). The algorithm uses the multidimensional raw data space to calculate surrogate attenuation values for the original metal traces in the raw data domain. The metal traces are detected automatically by a three-dimensional, threshold-based segmentation algorithm in an initial reconstructed image volume, based on twofold histogram information for calculating appropriate metal thresholds. These thresholds are combined with constrained morphological operations in the projection domain. A subsequent reconstruction of the modified raw data yields an artefact-reduced image volume that is further processed by a combining procedure that reinserts the missing metal information. For image quality assessment, measurements on semi-anthropomorphic phantoms containing metallic inserts were evaluated in terms of CT value accuracy, image noise and spatial resolution before and after correction. Measurements of the same phantoms without prostheses were used as ground truth for comparison. Cadaver measurements were performed on complex and realistic cases and to determine the influences of our correction method on the tissue surrounding the prostheses. The results showed a significant reduction of metal-induced streak artefacts (CT value differences were reduced to below 22 HU and image noise reduction of up to 200%). The cadaver measurements showed excellent results for imaging areas close to the implant and exceptional artefact suppression in these areas. Furthermore, measurements in the knee and spine regions confirmed the superiority of our method to standard one-dimensional, linear interpolation.
Greenbaum, Michael P.; Strom, Eric A.; Allen, Pamela K.; Perkins, George H.; Oh, Julia L.; Tereffe, Welela; Yu, Tse-Kuan; Buchholz, Thomas A.; Woodward, Wendy. A.
2011-01-01
Purpose To determine the rate of locoregional recurrence (LRR) associated with modern tri-modality therapy. Methods We retrospectively reviewed data from 291 consecutive PMRT patients treated from 1999 to 2001. These patients were compared to an historical group of 313 patients treated from 1979 to 1988 who had fluoroscopic simulation and contour-generated 2D planning. 1999–2001 spans the adoption of CT simulators for breast radiation therapy and a comparison was made between patients simulated before and after the implementation of CT simulation. Five-year actuarial rates for LRR, distal metastasis (DM), and overall survival (OS) between the pre and post CT simulation cohorts were compared as well. Results Compared to a 2D planned historic control, the combined contemporary patients had improved outcomes at 5 years for all endpoints studied; LRR 3.0% vs. 11.5%, DM 29.2% vs. 39.2%, and OS 79.2% vs. 70.6% (p = 0.0004, 0.0052, 0.0012, respectively). Significant factors in a multivariate analysis for LRR were: advanced T-stage (RR = 2.14, CI = 1.11–4.11, p = 0.023), and percent positive nodes (RR = 1.01, CI = 1.00–1.02, p = 0.012). The comparison of the pre and post CT-simulated PMRT patients (1999–2001) found no significant difference in any endpoint. Conclusions The rate of locoregional control for PMRT patients treated with modern radiotherapy is outstanding and has improved significantly compared to historical controls. PMID:20227126
Determination of split renal function using dynamic CT-angiography: preliminary results.
Helck, Andreas; Schönermarck, Ulf; Habicht, Antje; Notohamiprodjo, Mike; Stangl, Manfred; Klotz, Ernst; Nikolaou, Konstantin; la Fougère, Christian; Clevert, Dirk Andrè; Reiser, Maximilian; Becker, Christoph
2014-01-01
To determine the feasibility of a dynamic CT angiography-protocol with regard to simultaneous assessment of renal anatomy and function. 7 healthy potential kidney donors (58 ± 7 years) underwent a dynamic computed tomography angiography (CTA) using a 128-slice CT-scanner with continuous bi-directional table movement, allowing the coverage of a scan range of 18 cm within 1.75 sec. Twelve scans of the kidneys (n = 14) were acquired every 3.5 seconds with the aim to simultaneously obtain CTA and renal function data. Image quality was assessed quantitatively (HU-measurements) and qualitatively (grade 1-4, 1 = best). The glomerular filtration rate (GFR) was calculated by a modified Patlak method and compared with the split renal function obtained with renal scintigraphy. Mean maximum attenuation was 464 ± 58 HU, 435 ± 48 HU and 277 ± 29 HU in the aorta, renal arteries, and renal veins, respectively. The abdominal aorta and all renal vessels were depicted excellently (grade 1.0). The image quality score for cortex differentiation was 1.6 ± 0.49, for the renal parenchyma 2.4 ± 0.49. GFR obtained from dynamic CTA correlated well with renal scintigraphy with a correlation coefficient of r = 0.84; P = 0.0002 (n = 14). The average absolute deviation was 1.6 mL/min. The average effective dose was 8.96 mSv. Comprehensive assessment of renal anatomy and function is feasible using a single dynamic CT angiography examination. The proposed protocol may help to improve management in case of asymmetric kidney function as well as to simplify evaluation of potential living kidney donors.
Taxt-Lamolle, Sébastien F; Rubert, Marina; Haugen, Håvard J; Lyngstadaas, Ståle Petter; Ellingsen, Jan Eirik; Monjo, Marta
2010-03-01
Previous studies have shown that bone-to-implant attachment of titanium implants to cortical bone is improved when the surface is modified with hydrofluoric acid. The aim of this study was to investigate if biological factors are involved in the improved retention of these implants. Fluoride was implemented in implant surfaces by cathodic reduction with increasing concentrations of HF in the electrolyte. The modified implants were placed in the cortical bone in the tibias of New Zealand white rabbits. After 4 weeks of healing, wound fluid collected from the implant site showed lower lactate dehydrogenase activity and less bleeding in fluoride-modified implants compared to control. A significant increase in gene expression levels of osteocalcin and tartrate-resistant acid phosphatase (TRAP) was found in the cortical bone attached to Ti implants modified with 0.001 and 0.01 vol.% HF, while Ti implants modified with 0.1% HF showed only induced TRAP mRNA levels. These results were supported by the performed micro-CT analyses. The volumetric bone mineral density of the cortical bone hosting Ti implants modified with 0.001% and 0.01% HF was higher both in the newly woven bone (<100 microm from the interface) and in the older Haversian bone (>100 microm). In conclusion, the modulation of these biological factors by surface modification of titanium implants with low concentrations of HF using cathodic reduction may explain their improved osseointegration properties. Copyright 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Novel designed VmCT1 analogs with increased antimicrobial activity.
Pedron, Cibele Nicolaski; Torres, Marcelo Der Torossian; Lima, Julia Aparecida da Silva; Silva, Pedro Ismael; Silva, Fernanda Dias; Oliveira, Vani Xavier
2017-01-27
Antimicrobial peptides are biologically active molecules produced by a wide range of organisms as an essential component of the innate immune response. They have recently attracted great interest, since they have antimicrobial activity against a broad spectrum of microorganisms. VmCT1 is a cationic peptide from the venom of Vaejovis mexicanus smithi scorpions, which presents antibacterial activity and tends to helical structures. Its analogs were synthesized, characterized and the conformational studies were performed by circular dichroism. The peptides were designed to verify if the single and double substitutions proposed at the hydrophilic and hydrophobic portions of the amphipathic structure would alter antimicrobial activity against Gram-negative and Gram-positive bacteria, yeast and filamentous fungus, besides the hemolytic activity in human erythrocytes. Total charge of the peptides were modified from +2 to +3 by the introduction of a Lysine residue in the hydrophilic face of the amphiphilic helical structure leading to enhanced antimicrobial activity. [K] 11 -VmCT1-NH 2 presented the lower MIC value against the microorganisms (from 0.39 to 6.25 μmol L -1 ), however it showed higher hemolytic activity. The other Lysine-substituted analogs presented also lower MIC values ranging from 0.39 to 25 μmol L -1 for the microorganisms assessed. The circular dichroism spectra analyses suggest that the Lysine-substituted analogs tend to adopt helical structures in trifluoroethanol solution and vesicles (f H : 0.43-1), however they were coiled in water. Alanine substitution by a Glutamic acid residue in the hydrophilic face promotes the increase of polar angle in [E] 4 -VmCT1-NH 2 analog, which was important to led lower hemolytic activity (MHC value = 25 μmol L -1 ). [W] 9 -VmCT1-NH 2 and [E] 4 [W] 9 -VmCT1-NH 2 were designed to favors hydrophobic interactions by the introduction of Tryptophan residue. [W] 9 -VmCT1-NH 2 presented MIC values lower or similar than the model molecule in the most of microorganisms tested. These results provided information about the structure-activity relationship and showed the influence of physicochemical parameters on antimicrobial and hemolytic activity. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Patient-specific CT dosimetry calculation: a feasibility study.
Fearon, Thomas; Xie, Huchen; Cheng, Jason Y; Ning, Holly; Zhuge, Ying; Miller, Robert W
2011-11-15
Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient-specific CT dosimetry. A radiation treatment planning system was modified to calculate patient-specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose-volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi-empirical, measured correction-based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point-by-point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%-20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient-specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, P; Gang, Y; Qin, S
2016-06-15
Purpose: Many patients with technically unresectable or medically inoperable hepatocellular carcinoma (HCC) had hepatic dosimetric variations as a result of inter-fraction anatomical deformation. This study was conducted to assess the hepatic dosimetric consequences via reconstructing weekly dose in HCC patients receiving three dimensional conformal radiation therapy. Methods: Twenty-one HCC patients with 21 planning CT (pCT) scans and 63 weekly Cone-beam CT (CBCT) scans were enrolled in this investigation. Among them, six patients had been diagnosed of radiation induced liver disease (RILD) and the other fifteen patients had good prognosis after treatment. And each patient had three weekly CBCT before re-planning.more » In reconstructing CBCT-based weekly dose, we registered pCT to CBCT to provide the correct Hounsfield units for the CBCT using gradient-based deformable image registration (DIR), and this modified CBCT (mCBCT) were introduced to enable dose calculation.To obtain the weekly dosimetric consequences, the initial plan beam configurations and dose constraints were re-applied to mCBCT for performing dose calculation, and the mCBCT were extrapolated to 25 fractions. Besides, the manually delineated contour was propagated automatically onto the mCBCT of the new patient by exploiting the deformation vectors field, and the reconstructed weekly dose was mapped back to pCT to understand the dose distribution difference. Also, weekly dosimetric variations were compared with the hepatic radiation tolerance in terms of D50 and Dmean. Results: Among the twenty-one patients, the three weekly D50 increased by 0.7Gy, 5.1Gy and 6.1Gy, respectively, and Dmean increased by 0.9%, 4.7% and 5.5%, respectively. For patients with RILD, the average values of the third weekly D50 and Dmean were both high than hepatic radiation tolerance, while the values of patients without RILD were below. Conclusion: The planned dose on pCT was not a real dose to the liver, and the liver overdose increased the risk of RILD. The author would like to express great thanks to Lei Xing, Daniel S Kapp and Yong Yang in the Stanford University School of Medicine for their valuable suggestions to this work. This work is supported by NSFC(61471226), China Postdoctoral Science Foundation (2015T80739,2014M551949) and research funding from Shandong Province (JQ201516).« less
Liu, Dan; Khong, Pek-Lan; Gao, Yiming; Mahmood, Usman; Quinn, Brian; St Germain, Jean; Xu, X George; Dauer, Lawrence T
2016-06-01
Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. Consecutive adult patients with hepatocellular carcinoma who underwent whole-body dual-tracer PET/CT scans were retrospectively reviewed with institutional review board approval. OLINDA/EXM 1.1 was used to estimate patient-specific internal dose exposure in each organ. Biokinetic models for (18)F-FDG and (11)C-acetate as provided by ICRP (International Commission on Radiological Protection) publication 106 were used. Standard reference phantoms were modified to more closely represent patient-specific organ mass. With patient-specific parameters, organ equivalent doses from each CT series were estimated using VirtualDose. Dosimetry capabilities for tube current modulation protocols were applied by integrating with the latest anatomic realistic models. Effective dose was calculated using ICRP publication 103 tissue-weighting coefficients for adult male and female, respectively. Fourteen scans were evaluated (12 men, 2 women; mean age ± SD, 60 ± 19.48 y). The patient-specific effective dose from (18)F-FDG and (11)C-acetate was 6.08 ± 1.49 and 1.56 ± 0.47 mSv, respectively, for male patients and 6.62 ± 1.38 and 1.79 ± 0.12 mSV, respectively, for female patients. The patient-specific effective dose of the CT component, which comprised 2 noncontrast whole-body scans, to male and female patients was 21.20 ± 8.94 and 14.79 ± 3.35 mSv, respectively. Thus, the total effective doses of the combined whole-body dual-tracer PET/CT studies for male and female patients were 28.84 ± 10.18 and 23.19 ± 4.61 mSv, respectively. Patient-specific parameters allow for more accurate estimation of organ equivalent doses. Considering the substantial radiation dose incurred, judicious medical justification is required with every whole-body dual-tracer PET/CT referral. Although radiation risks may have less impact for the population with cancer because of their reduced life expectancy, the information is of interest and relevant for both justification, to evaluate risk/benefit, and protocol optimization. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Intradialytic Cognitive and Exercise Training May Preserve Cognitive Function.
McAdams-DeMarco, Mara A; Konel, Jonathan; Warsame, Fatima; Ying, Hao; Fernández, Marlís González; Carlson, Michelle C; Fine, Derek M; Appel, Lawrence J; Segev, Dorry L
2018-01-01
Cognitive decline is common and increases mortality risk in hemodialysis patients. Intradialytic interventions like cognitive training (CT) and exercise training (ET) may preserve cognitive function. We conducted a pilot randomized controlled trial of 20 hemodialysis patients to study the impact of 3 months of intradialytic CT (tablet-based brain games) (n = 7), ET (foot peddlers) (n = 6), or standard of care (SC) (n = 7) on cognitive function. Global cognitive function was measured by the Modified Mini Mental Status Exam (3MS), psychomotor speed was measured by Trail Making Tests A and B (TMTA and TMTB), and executive function was assessed by subtracting (TMTB - TMTA). Lower 3MS scores and slower TMTA and TMTB times reflected worse cognitive function. P values for differences were generated using analysis of variance, and 95% confidence intervals (CIs) and P values were generated from linear regression. Patients with SC experienced a decrease in psychomotor speed and executive function by 3 months (TMTA: 15 seconds; P = 0.055; TMTB: 47.4 seconds; P = 0.006; TMTB - TMTA; 31.7 seconds; P = 0.052); this decline was not seen among those with CT or ET (all P > 0.05). Compared with SC, the difference in the mean change in 3MS score was -3.29 points (95% CI: -11.70 to 5.12; P = 0.42) for CT and 4.48 points (95% CI: -4.27 to 13.22; P = 0.30) for ET. Compared with SC, the difference in mean change for TMTA was -15.13 seconds (95% CI: -37.64 to 7.39; P = 0.17) for CT and -17.48 seconds (95% CI: -41.18 to 6.22; P = 0.14) for ET, for TMTB, the difference was -46.72 seconds (95% CI: -91.12 to -2.31; P = 0.04) for CT and -56.21 seconds (95% CI: -105.86 to -6.56; P = 0.03) for ET, and for TMTB - TMTA, the difference was -30.88 seconds (95% CI: -76.05 to 14.28; P = 0.16) for CT and -34.93 seconds (95% CI: -85.43 to 15.56; P = 0.16) for ET. Preliminary findings of our pilot study suggested that cognitive decline in psychomotor speed and executive function is possibly prevented by intradialytic CT and ET. These preliminary pilot findings should be replicated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca; Haider, Masoom A.; Jaffray, David A.
Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarselymore » sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.« less
Lam, Karen; Chan, Conrad; Reilly, Raymond M.
2017-01-01
ABSTRACT We previously reported that microSPECT/CT imaging with 111In-labeled pertuzumab detected decreased HER2 expression in human breast cancer (BC) xenografts in athymic mice associated with response to treatment with trastuzumab (Herceptin). Our aim was to extend these results to PET/CT by constructing F(ab′)2 of pertuzumab modified with NOTA chelators for complexing 64Cu. The effect of the administered mass (5–200 µg) of 64Cu-NOTA-pertuzumab F(ab′)2 was studied in NOD/SCID mice engrafted with HER2-positive SK-OV-3 human ovarian cancer xenografts. Biodistribution studies were performed in non-tumor bearing Balb/c mice to predict radiation doses to normal organs in humans. Serial PET/CT imaging was conducted on mice engrafted with HER2-positive and trastuzumab-sensitive BT-474 or trastuzumab-insensitive SK-OV-3 xenografted mice treated with weekly doses of trastuzumab. There were no significant effects of the administered mass of 64Cu-NOTA-pertuzumab F(ab′)2 on tumor or normal tissue uptake. The predicted total body dose in humans was 0.015 mSv/MBq, a 3.3-fold reduction compared to 111In-labeled pertuzumab. MicroPET/CT images revealed specific tumor uptake of 64Cu-NOTA-pertuzumab F(ab′)2 at 24 or 48 h post-injection in mice with SK-OV-3 tumors. Image analysis of mice treated with trastuzumab showed 2-fold reduced uptake of 64Cu-NOTA-pertuzumab F(ab′)2 in BT-474 tumors after 1 week of trastuzumab normalized to baseline, and 1.9-fold increased uptake in SK-OV-3 tumors after 3 weeks of trastuzumab, consistent with tumor response and resistance, respectively. We conclude that PET/CT imaging with 64Cu-NOTA-pertuzumab F(ab′)2 detected changes in HER2 expression in response to trastuzumab while delivering a lower total body radiation dose compared to 111In-labeled pertuzumab. PMID:27813707
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, T; Diak, A; Surucu, M
Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions inmore » artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.« less
Smith, Emma L.; Roberts, Carol A.
2012-01-01
Understanding the structural development of embryonic bone in a three dimensional framework is fundamental to developing new strategies for the recapitulation of bone tissue in latter life. We present an innovative combined approach of an organotypic embryonic femur culture model, microcomputed tomography (μCT) and immunohistochemistry to examine the development and modulation of the three dimensional structures of the developing embryonic femur. Isolated embryonic chick femurs were organotypic (air/liquid interface) cultured for 10 days in either basal, chondrogenic, or osteogenic supplemented culture conditions. The growth development and modulating effects of basal, chondrogenic, or osteogenic culture media of the embryonic chick femurs was investigated using μCT, immunohistochemistry, and histology. The growth and development of noncultured embryonic chick femur stages E10, E11, E12, E13, E15, and E17 were very closely correlated with increased morphometric indices of bone formation as determined by μCT. After 10 days in the organotpyic culture set up, the early aged femurs (E10 and E11) demonstrated a dramatic response to the chondrogenic or osteogenic culture conditions compared to the basal cultured femurs as determined by a change in μCT morphometric indices and modified expression of chondrogenic and osteogenic markers. Although the later aged femurs (E12 and E13) increased in size and structure after 10 days organotpypic culture, the effects of the osteogenic and chondrogenic organotypic cultures on these femurs were not significantly altered compared to basal conditions. We have demonstrated that the embryonic chick femur organotpyic culture model combined with the μCT and immunohistochemical analysis can provide an integral methodology for investigating the modulation of bone development in an ex vivo culture setting. Hence, these interdisciplinary techniques of μCT and whole organ bone cultures will enable us to delineate some of the temporal, structural developmental paradigms and modulation of bone tissue formation to underpin innovative skeletal regenerative technology for clinical therapeutic strategies in musculoskeletal trauma and diseases. PMID:22472170
CT breast dose reduction with the use of breast positioning and organ-based tube current modulation.
Fu, Wanyi; Tian, Xiaoyu; Sturgeon, Gregory M; Agasthya, Greeshma; Segars, William Paul; Goodsitt, Mitchell M; Kazerooni, Ella A; Samei, Ehsan
2017-02-01
This study aimed to investigate the breast dose reduction potential of a breast-positioning (BP) technique for thoracic CT examinations with organ-based tube current modulation (OTCM). This study included 13 female anthropomorphic computational phantoms (XCAT, age range: 27-65 y.o., weight range: 52-105.8 kg). Each phantom was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were then morphed to emulate BP that constrained the majority of the breast tissue inside the 120° anterior tube current (mA) reduction zone. The OTCM mA value was modeled using a ray-tracing program, which reduced the mA to 20% in the anterior region with a corresponding increase to the posterior region. The organ doses were estimated by a validated Monte Carlo program for a typical clinical CT system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDI vol were used to compare three CT protocols: attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCM BP ). On average, compared to ATCM, OTCM reduced breast dose by 19.3 ± 4.5%, whereas OTCM BP reduced breast dose by 38.6 ± 8.1% (an additional 23.8 ± 9.4%). The dose saving of OTCM BP was more significant for larger breasts (on average 33, 38, and 44% reduction for 0.5, 1, and 2 kg breasts, respectively). Compared to ATCM, OTCM BP also reduced thymus and heart dose by 15.1 ± 7.4% and 15.9 ± 6.2% respectively. In thoracic CT examinations, OTCM with a breast-positioning technique can markedly reduce unnecessary exposure to radiosensitive organs in anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts. © 2016 American Association of Physicists in Medicine.
Temporal resolution improvement using PICCS in MDCT cardiac imaging
Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang
2009-01-01
The current paradigm for temporal resolution improvement is to add more source-detector units and∕or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120°, which is roughly 50% of the standard short-scan angular range (∼240° for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications. PMID:19610302
Temporal resolution improvement using PICCS in MDCT cardiac imaging.
Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang
2009-06-01
The current paradigm for temporal resolution improvement is to add more source-detector units and/or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120 degrees, which is roughly 50% of the standard short-scan angular range (approximately 240 degrees for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications.
Reiner, Caecilia S; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem
2016-03-01
To evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE). Sixteen patients (15 male; mean age 65 years; age range 47-80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters' ability to discriminate responders from non-responders. According to mRECIST, 8 patients (50%) were responders and 8 (50%) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min(-1) 100 mL(-1)); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min(-1) 100 mL(-1); p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min(-1) 100 mL(-1), therapy response could be predicted with a sensitivity of 88% (7/8) and specificity of 75% (6/8). Voxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.
Sowden, Gail; Hill, Jonathan C; Konstantinou, Kika; Khanna, Meenee; Main, Chris J; Salmon, Paula; Somerville, Simon; Wathall, Simon; Foster, Nadine E
2012-01-01
Background. The IMPaCT Back study (IMplementation to improve Patient Care through Targeted treatment for Back pain) is a quality improvement study which aims to investigate the effects of introducing and supporting a subgrouping for targeted treatment system for patients with low back pain (LBP) in primary care. This paper details the subgrouping for targeted treatment system and the clinical training and mentoring programmes aimed at equipping clinicians to deliver it. The subgrouping and targeted treatment system. This system differs from ‘one-size fits all’ usual practice as it suggests that first contact health care practitioners should systematically allocate LBP patients to one of the three subgroups according to key modifiable prognostic indicators for chronicity. Patients in each subgroup (those at low, medium or high risk of chronicity) are then managed according to a targeted treatment system of increasing complexity. The subgrouping tools. Subgrouping tools help guide clinical decision-making about treatment and onward referral. Two subgrouping tools have been used in the IMPaCT Back study, a 9-item version used by participating physiotherapists and a 6-item version used by GPs. The targeted treatments. The targeted treatments include a minimal intervention delivered by GPs (for those patients at low risk of poor outcome) or referral to primary care physiotherapists who can apply physiotherapy approaches to addressing pain and disability (for those at medium risk) and additional cognitive-behavioural approaches to help address psychological and social obstacles to recovery (for those at high risk). The training packages. Building on previous interventions for other pilot studies and randomized trials, we have developed and delivered clinical training and support programmes for GPs and physiotherapists. Discussion. This paper describes in detail the IMPaCT Back study’s subgrouping for targeted treatment system and the training and mentoring packages aimed at equipping clinicians to deliver it, within the IMPaCT Back study. Study registration. ISRCTN55174281. PMID:21708984
Kikuchi, Naoki; Yoshida, Shou; Okuyama, Mizuki; Nakazato, Koichi
2016-08-01
Kikuchi, N, Yoshida, S, Okuyama, M, and Nakazato, K. The effect of high-intensity interval cycling sprints subsequent to arm-curl exercise on upper-body muscle strength and hypertrophy. J Strength Cond Res 30(8): 2318-2323, 2016-The purpose of this study was to examine whether lower limb sprint interval training (SIT) after arm resistance training (RT) influences training response of arm muscle strength and hypertrophy. Twenty men participated in this study. We divided subjects into RT group (n = 6) and concurrent training group (CT, n = 6). The RT program was designed to induce muscular hypertrophy (3 sets × 10 repetitions [reps] at 80% 1 repetition maximum [1RM] of arm-curl exercise) and was performed in an 8-week training schedule performed 3 times per week on nonconsecutive days. Subjects assigned to the CT group performed identical protocols as strength training and modified SIT (4 sets of 30-s maximal effort, separated in 4 m 30-s rest intervals) on the same day. Pretest and posttest maximal oxygen consumption (V[Combining Dot Above]O2max), muscle cross-sectional area (CSA), and 1RM were measured. Significant increase in V[Combining Dot Above]O2max from pretest to posttest was observed in the CT group (p = 0.010, effect size [ES] = 1.84) but not in the RT group (p = 0.559, ES = 0.35). Significant increase in CSA from pretest to posttest was observed in the RT group (p = 0.030, ES = 1.49) but not in the CT group (p = 0.110, ES = 1.01). Significant increase in 1RM from pretest to posttest was observed in the RT group (p = 0.021, ES = 1.57) but not in the CT group (p = 0.065, ES = 1.19). In conclusion, our data indicate that concurrent lower limb SIT interferes with arm muscle hypertrophy and strength.
Enhancing Innovation and Underlying Neural Mechanisms Via Cognitive Training in Healthy Older Adults
Chapman, Sandra B.; Spence, Jeffrey S.; Aslan, Sina; Keebler, Molly W.
2017-01-01
Non-invasive interventions, such as cognitive training (CT) and physical exercise, are gaining momentum as ways to augment both cognitive and brain function throughout life. One of the most fundamental yet little studied aspects of human cognition is innovative thinking, especially in older adults. In this study, we utilize a measure of innovative cognition that examines both the quantity and quality of abstracted interpretations. This randomized pilot trial in cognitively normal adults (56–75 years) compared the effect of cognitive reasoning training (SMART) on innovative cognition as measured by Multiple Interpretations Measure (MIM). We also examined brain changes in relation to MIM using two MRI-based measurement of arterial spin labeling (ASL) to measure cerebral blood flow (CBF) and functional connectivity MRI (fcMRI) to measure default mode and central executive network (CEN) synchrony at rest. Participants (N = 58) were randomized to the CT, physical exercise (physical training, PT) or control (CN) group where CT and PT groups received training for 3 h/week over 12 weeks. They were assessed at baseline-, mid- and post-training using innovative cognition and MRI measures. First, the CT group showed significant gains pre- to post-training on the innovation measure whereas the physical exercise and control groups failed to show significant gains. Next, the CT group showed increased CBF in medial orbitofrontal cortex (mOFC) and bilateral posterior cingulate cortex (PCC), two nodes within the Default Mode Network (DMN) compared to physical exercise and control groups. Last, significant correlations were found between innovation performance and connectivity of two major networks: CEN (positive correlation) and DMN (negative correlation). These results support the view that both the CEN and DMN are important for enhancement of innovative cognition. We propose that neural mechanisms in healthy older adults can be modified through reasoning training to better subserve enhanced innovative cognition. PMID:29062276
SU-F-I-50: Finite Element-Based Deformable Image Registration of Lung and Heart
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penjweini, R; Kim, M; Zhu, T
Purpose: Photodynamic therapy (PDT) is used after surgical resection to treat the microscopic disease for malignant pleural mesothelioma and to increase survival rates. Although accurate light delivery is imperative to PDT efficacy, the deformation of the pleural volume during the surgery impacts the delivered light dose. To facilitate treatment planning, we use a finite-element-based (FEM) deformable image registration to quantify the anatomical variation of lung and heart volumes between CT pre-(or post-) surgery and surface contours obtained during PDT using an infrared camera-based navigation system (NDI). Methods: NDI is used during PDT to obtain the information of the cumulative lightmore » fluence on every cavity surface point that is being treated. A wand, comprised of a modified endotrachial tube filled with Intralipid and an optical fiber inside the tube, is used to deliver the light during PDT. The position of the treatment is tracked using an attachment with nine reflective passive markers that are seen by the NDI system. Then, the position points are plotted as three-dimensional volume of the pleural cavity using Matlab and Meshlab. A series of computed tomography (CT) scans of the lungs and heart, in the same patient, are also acquired before and after the surgery. The NDI and CT contours are imported into COMSOL Multiphysics, where the FEM-based deformable image registration is obtained. The NDI and CT contours acquired during and post-PDT are considered as the reference, and the Pre-PDT CT contours are used as the target, which will be deformed. Results: Anatomical variation of the lung and heart volumes, taken at different times from different imaging devices, was determined by using our model. The resulting three-dimensional deformation map along x, y and z-axes was obtained. Conclusion: Our model fuses images acquired by different modalities and provides insights into the variation in anatomical structures over time.« less
Shading correction assisted iterative cone-beam CT reconstruction
NASA Astrophysics Data System (ADS)
Yang, Chunlin; Wu, Pengwei; Gong, Shutao; Wang, Jing; Lyu, Qihui; Tang, Xiangyang; Niu, Tianye
2017-11-01
Recent advances in total variation (TV) technology enable accurate CT image reconstruction from highly under-sampled and noisy projection data. The standard iterative reconstruction algorithms, which work well in conventional CT imaging, fail to perform as expected in cone beam CT (CBCT) applications, wherein the non-ideal physics issues, including scatter and beam hardening, are more severe. These physics issues result in large areas of shading artifacts and cause deterioration to the piecewise constant property assumed in reconstructed images. To overcome this obstacle, we incorporate a shading correction scheme into low-dose CBCT reconstruction and propose a clinically acceptable and stable three-dimensional iterative reconstruction method that is referred to as the shading correction assisted iterative reconstruction. In the proposed method, we modify the TV regularization term by adding a shading compensation image to the reconstructed image to compensate for the shading artifacts while leaving the data fidelity term intact. This compensation image is generated empirically, using image segmentation and low-pass filtering, and updated in the iterative process whenever necessary. When the compensation image is determined, the objective function is minimized using the fast iterative shrinkage-thresholding algorithm accelerated on a graphic processing unit. The proposed method is evaluated using CBCT projection data of the Catphan© 600 phantom and two pelvis patients. Compared with the iterative reconstruction without shading correction, the proposed method reduces the overall CT number error from around 200 HU to be around 25 HU and increases the spatial uniformity by a factor of 20 percent, given the same number of sparsely sampled projections. A clinically acceptable and stable iterative reconstruction algorithm for CBCT is proposed in this paper. Differing from the existing algorithms, this algorithm incorporates a shading correction scheme into the low-dose CBCT reconstruction and achieves more stable optimization path and more clinically acceptable reconstructed image. The method proposed by us does not rely on prior information and thus is practically attractive to the applications of low-dose CBCT imaging in the clinic.
ImaSim, a software tool for basic education of medical x-ray imaging in radiotherapy and radiology
NASA Astrophysics Data System (ADS)
Landry, Guillaume; deBlois, François; Verhaegen, Frank
2013-11-01
Introduction: X-ray imaging is an important part of medicine and plays a crucial role in radiotherapy. Education in this field is mostly limited to textbook teaching due to equipment restrictions. A novel simulation tool, ImaSim, for teaching the fundamentals of the x-ray imaging process based on ray-tracing is presented in this work. ImaSim is used interactively via a graphical user interface (GUI). Materials and methods: The software package covers the main x-ray based medical modalities: planar kilo voltage (kV), planar (portal) mega voltage (MV), fan beam computed tomography (CT) and cone beam CT (CBCT) imaging. The user can modify the photon source, object to be imaged and imaging setup with three-dimensional editors. Objects are currently obtained by combining blocks with variable shapes. The imaging of three-dimensional voxelized geometries is currently not implemented, but can be added in a later release. The program follows a ray-tracing approach, ignoring photon scatter in its current implementation. Simulations of a phantom CT scan were generated in ImaSim and were compared to measured data in terms of CT number accuracy. Spatial variations in the photon fluence and mean energy from an x-ray tube caused by the heel effect were estimated from ImaSim and Monte Carlo simulations and compared. Results: In this paper we describe ImaSim and provide two examples of its capabilities. CT numbers were found to agree within 36 Hounsfield Units (HU) for bone, which corresponds to a 2% attenuation coefficient difference. ImaSim reproduced the heel effect reasonably well when compared to Monte Carlo simulations. Discussion: An x-ray imaging simulation tool is made available for teaching and research purposes. ImaSim provides a means to facilitate the teaching of medical x-ray imaging.
Jing, Xueping; Zheng, Xiujuan; Song, Shaoli; Liu, Kai
2017-12-01
Glomerular filtration rate (GFR), which can be estimated by Gates method with dynamic kidney single photon emission computed tomography (SPECT) imaging, is a key indicator of renal function. In this paper, an automatic computer tomography (CT)-assisted detection method of kidney region of interest (ROI) is proposed to achieve the objective and accurate GFR calculation. In this method, the CT coronal projection image and the enhanced SPECT synthetic image are firstly generated and registered together. Then, the kidney ROIs are delineated using a modified level set algorithm. Meanwhile, the background ROIs are also obtained based on the kidney ROIs. Finally, the value of GFR is calculated via Gates method. Comparing with the clinical data, the GFR values estimated by the proposed method were consistent with the clinical reports. This automatic method can improve the accuracy and stability of kidney ROI detection for GFR calculation, especially when the kidney function has been severely damaged.
In-vivo x-ray micro-imaging and micro-CT with the Medipix2 semiconductor detector at UniAndes
NASA Astrophysics Data System (ADS)
Caicedo, I.; Avila, C.; Gomez, B.; Bula, C.; Roa, C.; Sanabria, J.
2012-02-01
This poster contains the procedure to obtain micro-CTs and to image moving samples using the Medipix2 detector, with its corresponding results. The high granularity of the detector makes it suitable for micro-CT. We used commercial software (Octopus) to do the 3D reconstruction of the samples in the first place, and we worked on modifying free reconstruction software afterwards. Medipix has a very fast response ( ~ hundreds of nanoseconds) and high sensibility. These features allow obtaining nearly in-vivo high resolution (55m * 55m) images. We used an exposure time of 0.1 s for each frame, and the resulting images were animated. The High Energy Physics Group at UniAndes is a member of the Medipix3 collaboration. Its research activities are focused on developing set-ups for biomedical applications and particle tracking using the Medipix2 and Timepix detectors, and assessing the feasibility of the Medipix3 detector for future applications.
Saliency U-Net: A regional saliency map-driven hybrid deep learning network for anomaly segmentation
NASA Astrophysics Data System (ADS)
Karargyros, Alex; Syeda-Mahmood, Tanveer
2018-02-01
Deep learning networks are gaining popularity in many medical image analysis tasks due to their generalized ability to automatically extract relevant features from raw images. However, this can make the learning problem unnecessarily harder requiring network architectures of high complexity. In case of anomaly detection, in particular, there is often sufficient regional difference between the anomaly and the surrounding parenchyma that could be easily highlighted through bottom-up saliency operators. In this paper we propose a new hybrid deep learning network using a combination of raw image and such regional maps to more accurately learn the anomalies using simpler network architectures. Specifically, we modify a deep learning network called U-Net using both the raw and pre-segmented images as input to produce joint encoding (contraction) and expansion paths (decoding) in the U-Net. We present results of successfully delineating subdural and epidural hematomas in brain CT imaging and liver hemangioma in abdominal CT images using such network.
Hematoma Expansion Following Acute Intracerebral Hemorrhage
Brouwers, H. Bart; Greenberg, Steven M.
2013-01-01
Intracerebral hemorrhage, the most devastating form of stroke, has no specific therapy proven to improve outcome by randomized controlled trial. Location and baseline hematoma volume are strong predictors of mortality, but are non-modifiable by the time of diagnosis. Expansion of the initial hematoma is a further marker of poor prognosis that may be at least partly preventable. Several risk factors for hematoma expansion have been identified, including baseline ICH volume, early presentation after symptom onset, anticoagulation, and the CT angiography spot sign. Although the biological mechanisms of hematoma expansion remain unclear, accumulating evidence supports a model of ongoing secondary bleeding from ruptured adjacent vessels surrounding the initial bleeding site. Several large clinical trials testing therapies aimed at preventing hematoma expansion are in progress, including aggressive blood pressure reduction, treatment with recombinant factor VIIa guided by CT angiography findings, and surgical intervention for superficial hematomas without intraventricular extension. Hematoma expansion is so far the only marker of outcome that is amenable to treatment and thus a potentially important therapeutic target. PMID:23466430
Modified nanoparticle mediated IL-12 immunogene therapy for colon cancer.
Liu, Xiaoxiao; Gao, Xiang; Zheng, Songping; Wang, Bilan; Li, Yanyan; Zhao, Chanjuan; Muftuoglu, Yagmur; Chen, Song; Li, Ying; Yao, Haiyan; Sun, Hui; Mao, Qing; You, Chao; Guo, Gang; Wei, Yuquan
2017-08-01
For the past few years, immunotherapy has recently shown considerable clinical benefit in CRC therapy, and the application of immunologic therapies in cancer treatments continues to increase perennially. Interleukin-12, an ideal candidate for tumor immunotherapy, could activate both innate and adaptive immunities. In this study, we developed a novel gene delivery system with a self-assembly method by MPEG-PLA and DOTAP(DMP) with zeta-potential value of 38.5mV and size of 37.5nm. The supernatant of lymphocytes treated with supernatant from Ct26 transfected pIL12 with DMP could inhibit Ct26 cells growth ex vivo. Treatment of tumor-bearing mice with DMP-pIL12 complex has significantly inhibited tumor growth at both the subcutaneous and peritoneal model in vivo by inhibiting angiogenesis, promoting apoptosis and reducing proliferation. The IL-12 plasmid and DMP complex may be used to treat the colorectal cancer in clinical as a new drug. Copyright © 2017 Elsevier Inc. All rights reserved.
Song, David Sheng; Taylor, Christopher Alan; Mejia, Alfredo; Melgar-Quiñonez, Hugo; Balcazar, Hector G.; Anders, Robert L.; Segura-Pérez, Sofia; Duarte-Gardea, Maria O.; Ibarra, Jorge M.
2010-01-01
This cross-sectional study assessed: (a) awareness and knowledge of federal dietary tools (MyPyramid, Food Guide Pyramid (FGP), and food labels (FL)), and (b) the influence of acculturation and state of residence on FGP knowledge (FGPK) indicators among low-income Latina WIC participants (N = 479) living in Connecticut, Ohio, Texas, and California. Participants were familiar with FGP but only 37% recognized MyPyramid. FGPK was highest for fruits (71%) and lowest for the ‘breads and cereals’ group (12%). Less than half (47%) used FL’s when grocery shopping. Living in OH, was associated with the lowest FGPK. Multivariate analyses showed that more acculturated individuals living in CT/CA had better FGPK than participants living in TX and their less acculturated counterparts in CT/CA. The forthcoming revised federal dietary tools need to be adequately disseminated among Latinos, with special emphasis on those with lower acculturation levels, living in rapid emerging Latino communities or in the US–Mexico border. PMID:20549357
Baum, Richard P.; Kulkarni, Harshad R.
2012-01-01
The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs) using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT), and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction. PMID:22768024
Baum, Richard P; Kulkarni, Harshad R
2012-01-01
The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs) using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT), and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction.
NASA Astrophysics Data System (ADS)
Wolfs, Cecile J. A.; Brás, Mariana G.; Schyns, Lotte E. J. R.; Nijsten, Sebastiaan M. J. J. G.; van Elmpt, Wouter; Scheib, Stefan G.; Baltes, Christof; Podesta, Mark; Verhaegen, Frank
2017-08-01
The aim of this work is to assess the performance of 2D time-integrated (2D-TI), 2D time-resolved (2D-TR) and 3D time-integrated (3D-TI) portal dosimetry in detecting dose discrepancies between the planned and (simulated) delivered dose caused by simulated changes in the anatomy of lung cancer patients. For six lung cancer patients, tumor shift, tumor regression and pleural effusion are simulated by modifying their CT images. Based on the modified CT images, time-integrated (TI) and time-resolved (TR) portal dose images (PDIs) are simulated and 3D-TI doses are calculated. The modified and original PDIs and 3D doses are compared by a gamma analysis with various gamma criteria. Furthermore, the difference in the D 95% (ΔD 95%) of the GTV is calculated and used as a gold standard. The correlation between the gamma fail rate and the ΔD 95% is investigated, as well the sensitivity and specificity of all combinations of portal dosimetry method, gamma criteria and gamma fail rate threshold. On the individual patient level, there is a correlation between the gamma fail rate and the ΔD 95%, which cannot be found at the group level. The sensitivity and specificity analysis showed that there is not one combination of portal dosimetry method, gamma criteria and gamma fail rate threshold that can detect all simulated anatomical changes. This work shows that it will be more beneficial to relate portal dosimetry and DVH analysis on the patient level, rather than trying to quantify a relationship for a group of patients. With regards to optimizing sensitivity and specificity, different combinations of portal dosimetry method, gamma criteria and gamma fail rate should be used to optimally detect certain types of anatomical changes.
Wolfs, Cecile J A; Brás, Mariana G; Schyns, Lotte E J R; Nijsten, Sebastiaan M J J G; van Elmpt, Wouter; Scheib, Stefan G; Baltes, Christof; Podesta, Mark; Verhaegen, Frank
2017-07-12
The aim of this work is to assess the performance of 2D time-integrated (2D-TI), 2D time-resolved (2D-TR) and 3D time-integrated (3D-TI) portal dosimetry in detecting dose discrepancies between the planned and (simulated) delivered dose caused by simulated changes in the anatomy of lung cancer patients. For six lung cancer patients, tumor shift, tumor regression and pleural effusion are simulated by modifying their CT images. Based on the modified CT images, time-integrated (TI) and time-resolved (TR) portal dose images (PDIs) are simulated and 3D-TI doses are calculated. The modified and original PDIs and 3D doses are compared by a gamma analysis with various gamma criteria. Furthermore, the difference in the D 95% (ΔD 95% ) of the GTV is calculated and used as a gold standard. The correlation between the gamma fail rate and the ΔD 95% is investigated, as well the sensitivity and specificity of all combinations of portal dosimetry method, gamma criteria and gamma fail rate threshold. On the individual patient level, there is a correlation between the gamma fail rate and the ΔD 95% , which cannot be found at the group level. The sensitivity and specificity analysis showed that there is not one combination of portal dosimetry method, gamma criteria and gamma fail rate threshold that can detect all simulated anatomical changes. This work shows that it will be more beneficial to relate portal dosimetry and DVH analysis on the patient level, rather than trying to quantify a relationship for a group of patients. With regards to optimizing sensitivity and specificity, different combinations of portal dosimetry method, gamma criteria and gamma fail rate should be used to optimally detect certain types of anatomical changes.
Li, Ke; Tang, Jie; Chen, Guang-Hong
2014-04-01
To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo(®), GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a "redder" NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose)(-β) with the component β ≈ 0.25, which violated the classical σ ∝ (dose)(-0.5) power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement. © 2014 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ke; Tang, Jie; Chen, Guang-Hong, E-mail: gchen7@wisc.edu
Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD,more » GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a “redder” NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose){sup −β} with the component β ≈ 0.25, which violated the classical σ ∝ (dose){sup −0.5} power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. Conclusions: The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement.« less
Effects of acids on neural activity elicited by other taste stimuli in the rat Chorda tympani.
Sakurai, N; Kanemura, F; Watanabe, K; Shimizu, Y; Tonosaki, K
2000-03-24
The purpose of this study is whether the gustatory neural response of taste cell to a binary mixture with threshold concentration of acid becomes synergistic or antagonistic can be estimated from the whole chorda tympani (CT) nerve in the rat. The present data demonstrate that acids are synergistic enhancer for sugars, and suppressor for NaCl and QHCl, but no effect to glycine and alanine. These results suggest that the acid was modifying the interaction of the other stimulus with its transduction mechanism.
1982-12-01
093 .031 .026 E 116,292 56,424 44,906 12,354 L.L.S. c 2280 802 351 OW Average k .360 .074* .022* .009* Slope f 116,892 51,187 35,276 8,318 Modified c...LE.O.)THEN gELY =1. RGE1=RGE 1.1 ELS E X (CT-C) /THETA)**KI IF(XeLTo20.)THE4. RErLY=EXP(-X) ELSE RELY=O. END IF E"’D IF RETURN EN) 66 I APPENDIX B
Zhang, Lingli; Zeng, Li; Guo, Yumeng
2018-01-01
Restricted by the scanning environment in some CT imaging modalities, the acquired projection data are usually incomplete, which may lead to a limited-angle reconstruction problem. Thus, image quality usually suffers from the slope artifacts. The objective of this study is to first investigate the distorted domains of the reconstructed images which encounter the slope artifacts and then present a new iterative reconstruction method to address the limited-angle X-ray CT reconstruction problem. The presented framework of new method exploits the structural similarity between the prior image and the reconstructed image aiming to compensate the distorted edges. Specifically, the new method utilizes l0 regularization and wavelet tight framelets to suppress the slope artifacts and pursue the sparsity. New method includes following 4 steps to (1) address the data fidelity using SART; (2) compensate for the slope artifacts due to the missed projection data using the prior image and modified nonlocal means (PNLM); (3) utilize l0 regularization to suppress the slope artifacts and pursue the sparsity of wavelet coefficients of the transformed image by using iterative hard thresholding (l0W); and (4) apply an inverse wavelet transform to reconstruct image. In summary, this method is referred to as "l0W-PNLM". Numerical implementations showed that the presented l0W-PNLM was superior to suppress the slope artifacts while preserving the edges of some features as compared to the commercial and other popular investigative algorithms. When the image to be reconstructed is inconsistent with the prior image, the new method can avoid or minimize the distorted edges in the reconstructed images. Quantitative assessments also showed that applying the new method obtained the highest image quality comparing to the existing algorithms. This study demonstrated that the presented l0W-PNLM yielded higher image quality due to a number of unique characteristics, which include that (1) it utilizes the structural similarity between the reconstructed image and prior image to modify the distorted edges by slope artifacts; (2) it adopts wavelet tight frames to obtain the first and high derivative in several directions and levels; and (3) it takes advantage of l0 regularization to promote the sparsity of wavelet coefficients, which is effective for the inhibition of the slope artifacts. Therefore, the new method can address the limited-angle CT reconstruction problem effectively and have practical significance.
Wada, Kota; Ishigaki, Takashi; Ida, Yutaro; Yamada, Yuki; Hosono, Sachiko; Edamatsu, Hideo
2015-01-01
For treatment of a sinonasal inverted papilloma (IP), it is essential to have a definite diagnosis, to identify its origin by computed tomography (CT) and magnetic resonance imaging (MRI), and to select the appropriate surgical approach based on the staging system proposed by Krouse. Recently, a new surgical approach named endoscopic modified medial maxillectomy (EMMM) was proposed. This approach can preserve the inferior turbinate and nasolacrimal duct. We successfully treated sinonasal IP with EMMM in a 71-year-old female patient. In this patient, the sinonasal IP originated from the entire circumference of the maxillary sinus. EMMM is not a difficult procedure and provides good visibility of the operative field. Lacrimation and empty nose syndrome do not occur postoperatively as the nasolacrimal duct and inferior turbinate are preserved. EMMM is considered to be a very favorable approach for treatment of sinonasal IP. PMID:26146581
Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d'Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico
2016-01-01
The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS ≤ 2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gay, Hiram A., E-mail: hgay@radonc.wustl.edu; Barthold, H. Joseph; Beth Israel Deaconess Medical Center, Boston, MA
2012-07-01
Purpose: To define a male and female pelvic normal tissue contouring atlas for Radiation Therapy Oncology Group (RTOG) trials. Methods and Materials: One male pelvis computed tomography (CT) data set and one female pelvis CT data set were shared via the Image-Guided Therapy QA Center. A total of 16 radiation oncologists participated. The following organs at risk were contoured in both CT sets: anus, anorectum, rectum (gastrointestinal and genitourinary definitions), bowel NOS (not otherwise specified), small bowel, large bowel, and proximal femurs. The following were contoured in the male set only: bladder, prostate, seminal vesicles, and penile bulb. The followingmore » were contoured in the female set only: uterus, cervix, and ovaries. A computer program used the binomial distribution to generate 95% group consensus contours. These contours and definitions were then reviewed by the group and modified. Results: The panel achieved consensus definitions for pelvic normal tissue contouring in RTOG trials with these standardized names: Rectum, AnoRectum, SmallBowel, Colon, BowelBag, Bladder, UteroCervix, Adnexa{sub R}, Adnexa{sub L}, Prostate, SeminalVesc, PenileBulb, Femur{sub R}, and Femur{sub L}. Two additional normal structures whose purpose is to serve as targets in anal and rectal cancer were defined: AnoRectumSig and Mesorectum. Detailed target volume contouring guidelines and images are discussed. Conclusions: Consensus guidelines for pelvic normal tissue contouring were reached and are available as a CT image atlas on the RTOG Web site. This will allow uniformity in defining normal tissues for clinical trials delivering pelvic radiation and will facilitate future normal tissue complication research.« less
Motion compensation for cone-beam CT using Fourier consistency conditions
NASA Astrophysics Data System (ADS)
Berger, M.; Xia, Y.; Aichinger, W.; Mentl, K.; Unberath, M.; Aichert, A.; Riess, C.; Hornegger, J.; Fahrig, R.; Maier, A.
2017-09-01
In cone-beam CT, involuntary patient motion and inaccurate or irreproducible scanner motion substantially degrades image quality. To avoid artifacts this motion needs to be estimated and compensated during image reconstruction. In previous work we showed that Fourier consistency conditions (FCC) can be used in fan-beam CT to estimate motion in the sinogram domain. This work extends the FCC to 3\\text{D} cone-beam CT. We derive an efficient cost function to compensate for 3\\text{D} motion using 2\\text{D} detector translations. The extended FCC method have been tested with five translational motion patterns, using a challenging numerical phantom. We evaluated the root-mean-square-error and the structural-similarity-index between motion corrected and motion-free reconstructions. Additionally, we computed the mean-absolute-difference (MAD) between the estimated and the ground-truth motion. The practical applicability of the method is demonstrated by application to respiratory motion estimation in rotational angiography, but also to motion correction for weight-bearing imaging of knees. Where the latter makes use of a specifically modified FCC version which is robust to axial truncation. The results show a great reduction of motion artifacts. Accurate estimation results were achieved with a maximum MAD value of 708 μm and 1184 μm for motion along the vertical and horizontal detector direction, respectively. The image quality of reconstructions obtained with the proposed method is close to that of motion corrected reconstructions based on the ground-truth motion. Simulations using noise-free and noisy data demonstrate that FCC are robust to noise. Even high-frequency motion was accurately estimated leading to a considerable reduction of streaking artifacts. The method is purely image-based and therefore independent of any auxiliary data.
NASA Astrophysics Data System (ADS)
Matsumoto, Monica M. S.; Beig, Niha G.; Udupa, Jayaram K.; Archer, Steven; Torigian, Drew A.
2014-03-01
Lung cancer is associated with the highest cancer mortality rates among men and women in the United States. The accurate and precise identification of the lymph node stations on computed tomography (CT) images is important for staging disease and potentially for prognosticating outcome in patients with lung cancer, as well as for pretreatment planning and response assessment purposes. To facilitate a standard means of referring to lymph nodes, the International Association for the Study of Lung Cancer (IASLC) has recently proposed a definition of the different lymph node stations and zones in the thorax. However, nodal station identification is typically performed manually by visual assessment in clinical radiology. This approach leaves room for error due to the subjective and potentially ambiguous nature of visual interpretation, and is labor intensive. We present a method of automatically recognizing the mediastinal IASLC-defined lymph node stations by modifying a hierarchical fuzzy modeling approach previously developed for body-wide automatic anatomy recognition (AAR) in medical imagery. Our AAR-lymph node (AAR-LN) system follows the AAR methodology and consists of two steps. In the first step, the various lymph node stations are manually delineated on a set of CT images following the IASLC definitions. These delineations are then used to build a fuzzy hierarchical model of the nodal stations which are considered as 3D objects. In the second step, the stations are automatically located on any given CT image of the thorax by using the hierarchical fuzzy model and object recognition algorithms. Based on 23 data sets used for model building, 22 independent data sets for testing, and 10 lymph node stations, a mean localization accuracy of within 1-6 voxels has been achieved by the AAR-LN system.
Deep-learning derived features for lung nodule classification with limited datasets
NASA Astrophysics Data System (ADS)
Thammasorn, P.; Wu, W.; Pierce, L. A.; Pipavath, S. N.; Lampe, P. D.; Houghton, A. M.; Haynor, D. R.; Chaovalitwongse, W. A.; Kinahan, P. E.
2018-02-01
Only a few percent of indeterminate nodules found in lung CT images are cancer. However, enabling earlier diagnosis is important to avoid invasive procedures or long-time surveillance to those benign nodules. We are evaluating a classification framework using radiomics features derived with a machine learning approach from a small data set of indeterminate CT lung nodule images. We used a retrospective analysis of 194 cases with pulmonary nodules in the CT images with or without contrast enhancement from lung cancer screening clinics. The nodules were contoured by a radiologist and texture features of the lesion were calculated. In addition, sematic features describing shape were categorized. We also explored a Multiband network, a feature derivation path that uses a modified convolutional neural network (CNN) with a Triplet Network. This was trained to create discriminative feature representations useful for variable-sized nodule classification. The diagnostic accuracy was evaluated for multiple machine learning algorithms using texture, shape, and CNN features. In the CT contrast-enhanced group, the texture or semantic shape features yielded an overall diagnostic accuracy of 80%. Use of a standard deep learning network in the framework for feature derivation yielded features that substantially underperformed compared to texture and/or semantic features. However, the proposed Multiband approach of feature derivation produced results similar in diagnostic accuracy to the texture and semantic features. While the Multiband feature derivation approach did not outperform the texture and/or semantic features, its equivalent performance indicates promise for future improvements to increase diagnostic accuracy. Importantly, the Multiband approach adapts readily to different size lesions without interpolation, and performed well with relatively small amount of training data.
ACR appropriateness criteria blunt chest trauma.
Chung, Jonathan H; Cox, Christian W; Mohammed, Tan-Lucien H; Kirsch, Jacobo; Brown, Kathleen; Dyer, Debra Sue; Ginsburg, Mark E; Heitkamp, Darel E; Kanne, Jeffrey P; Kazerooni, Ella A; Ketai, Loren H; Ravenel, James G; Saleh, Anthony G; Shah, Rakesh D; Steiner, Robert M; Suh, Robert D
2014-04-01
Imaging is paramount in the setting of blunt trauma and is now the standard of care at any trauma center. Although anteroposterior radiography has inherent limitations, the ability to acquire a radiograph in the trauma bay with little interruption in clinical survey, monitoring, and treatment, as well as radiography's accepted role in screening for traumatic aortic injury, supports the routine use of chest radiography. Chest CT or CT angiography is the gold-standard routine imaging modality for detecting thoracic injuries caused by blunt trauma. There is disagreement on whether routine chest CT is necessary in all patients with histories of blunt trauma. Ultimately, the frequency and timing of CT chest imaging should be site specific and should depend on the local resources of the trauma center as well as patient status. Ultrasound may be beneficial in the detection of pneumothorax, hemothorax, and pericardial hemorrhage; transesophageal echocardiography is a first-line imaging tool in the setting of suspected cardiac injury. In the blunt trauma setting, MRI and nuclear medicine likely play no role in the acute setting, although these modalities may be helpful as problem-solving tools after initial assessment. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 2 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Sato, Shoichiro; Delcourt, Candice; Zhang, Shihong; Arima, Hisatomi; Heeley, Emma; Zheng, Danni; Al-Shahi Salman, Rustam; Stapf, Christian; Tzourio, Christophe; Robinson, Thompson; Lindley, Richard I; Chalmers, John; Anderson, Craig S
2016-01-01
This study aimed at identifying the determinants and prognostic significance of a sedimentation level (fluid-blood level) in the hematoma among patients with acute intracerebral hemorrhage (ICH) who participated in the main Intensive Blood Pressure Reduction in Acute Cerebral Hemorrhage Trial (INTERACT2). Post-hoc analysis of the INTERACT2 dataset, a randomized controlled trial of patients with acute ICH with elevated systolic blood pressure (SBP), randomly assigned to intensive (target SBP <140 mm Hg) or guideline-based (<180 mm Hg) BP management. Patients with a sedimentation level at baseline assessment on CT, and modified Rankin Scale score at 90-day, were included in these analyses. Factors associated with a sedimentation level and its significance in relation to 90-day clinical outcomes were assessed in univariable and multivariable logistic regression models. Of 2,065 participants, 19 (1%) had sedimentation level on baseline CT, which was independently associated with warfarin use (p = 0.006) and lobar ICH (p = 0.025). Sedimentation level was also associated with death or major disability at 90-day in both crude (84 vs. 53%; p = 0.014) and multivariable analyses adjusted for age, gender, Chinese region, warfarin use, baseline National Institutes of Health Stroke Scale score, onset to CT time, volume and location of ICH, intraventricular extension, and randomized intensive BP lowering (OR 3.94, 95% CI 1.01-15.37; p = 0.049). The presence of hematoma sedimentation level on baseline CT is associated with warfarin use and lobar location of ICH, and predicts a worse outcome. Although uncommon, sedimentation level is an easily detectable prognostic factor in acute ICH. © 2015 S. Karger AG, Basel.
González, R. Gilberto; Lev, Michael H.; Goldmacher, Gregory V.; Smith, Wade S.; Payabvash, Seyedmehdi; Harris, Gordon J.; Halpern, Elkan F.; Koroshetz, Walter J.; Camargo, Erica C. S.; Dillon, William P.; Furie, Karen L.
2012-01-01
Purpose To improve ischemic stroke outcome prediction using imaging information from a prospective cohort who received admission CT angiography (CTA). Methods In a prospectively designed study, 649 stroke patients diagnosed with acute ischemic stroke had admission NIH stroke scale scores, noncontrast CT (NCCT), CTA, and 6-month outcome assessed using the modified Rankin scale (mRS) scores. Poor outcome was defined as mRS>2. Strokes were classified as “major” by the (1) Alberta Stroke Program Early CT Score (ASPECTS+) if NCCT ASPECTS was≤7; (2) Boston Acute Stroke Imaging Scale (BASIS+) if they were ASPECTS+ or CTA showed occlusion of the distal internal carotid, proximal middle cerebral, or basilar arteries; and (3) NIHSS for scores>10. Results Of 649 patients, 253 (39.0%) had poor outcomes. NIHSS, BASIS, and age, but not ASPECTS, were independent predictors of outcome. BASIS and NIHSS had similar sensitivities, both superior to ASPECTS (p<0.0001). Combining NIHSS with BASIS was highly predictive: 77.6% (114/147) classified as NIHSS>10/BASIS+ had poor outcomes, versus 21.5% (77/358) with NIHSS≤10/BASIS− (p<0.0001), regardless of treatment. The odds ratios for poor outcome is 12.6 (95% CI: 7.9 to 20.0) in patients who are NIHSS>10/BASIS+ compared to patients who are NIHSS≤10/BASIS−; the odds ratio is 5.4 (95% CI: 3.5 to 8.5) when compared to patients who are only NIHSS>10 or BASIS+. Conclusions BASIS and NIHSS are independent outcome predictors. Their combination is stronger than either instrument alone in predicting outcomes. The findings suggest that CTA is a significant clinical tool in routine acute stroke assessment. PMID:22276182
The algorithm study for using the back propagation neural network in CT image segmentation
NASA Astrophysics Data System (ADS)
Zhang, Peng; Liu, Jie; Chen, Chen; Li, Ying Qi
2017-01-01
Back propagation neural network(BP neural network) is a type of multi-layer feed forward network which spread positively, while the error spread backwardly. Since BP network has advantages in learning and storing the mapping between a large number of input and output layers without complex mathematical equations to describe the mapping relationship, it is most widely used. BP can iteratively compute the weight coefficients and thresholds of the network based on the training and back propagation of samples, which can minimize the error sum of squares of the network. Since the boundary of the computed tomography (CT) heart images is usually discontinuous, and it exist large changes in the volume and boundary of heart images, The conventional segmentation such as region growing and watershed algorithm can't achieve satisfactory results. Meanwhile, there are large differences between the diastolic and systolic images. The conventional methods can't accurately classify the two cases. In this paper, we introduced BP to handle the segmentation of heart images. We segmented a large amount of CT images artificially to obtain the samples, and the BP network was trained based on these samples. To acquire the appropriate BP network for the segmentation of heart images, we normalized the heart images, and extract the gray-level information of the heart. Then the boundary of the images was input into the network to compare the differences between the theoretical output and the actual output, and we reinput the errors into the BP network to modify the weight coefficients of layers. Through a large amount of training, the BP network tend to be stable, and the weight coefficients of layers can be determined, which means the relationship between the CT images and the boundary of heart.
Association between tuberculosis and atopy: role of the CD14-159C/T polymorphism.
Baççioğlu Kavut, A; Kalpaklioğlu, F; Birben, E; Ayaslioğlu, E
2012-01-01
The development of allergic hypersensitivity depends on both genetic and environmental factors. Different amounts of microbial products could affect patients with atopy and different genotypes. We aimed to evaluate the role of varying degrees of exposure to infection by Mycobacterium tuberculosis (tuberculosis) in atopic patients and analyze the association with genetic factors. We performed CD14-159C/T genotyping in atopic patients (n=118) and healthy individuals (n=62) and recorded the following variables: rural lifestyle, exposure to persons with tuberculosis, bacille Calmette-Guerin (BCG) vaccination, tuberculin skin test (TST), skin prick test, and phenotypes of atopy. Blood samples were analyzed for soluble-CD14 (sCD14), interferon (IFN) y, total immunoglobulin (Ig) E, and eosinophil levels. A score was used to identify the likelihood of exposure to tuberculosis. Almost all the study participants had had a BCG vaccination, and half had a positive TST result. No differences were observed between atopic patients with high/low tuberculosis scores and CD14 genotypes in terms of atopic phenotypes, allergen sensitization, and levels of total IgE, sCD14, and IFN-y. However, the frequency of asthma was higher in atopic patients with a high tuberculosis score and was not associated with CD14 genotypes. Eosinophil counts in blood were higher in atopic patients with a high tuberculosis score and CC+CT genotypes. These results suggest that the C allele of the CD14-159C/T polymorphism has a marked effect on eosinophil levels in atopic patients with increased exposure to tuberculosis. In addition, the degree of exposure to tuberculosis in atopic patients may modify the development of asthma.
Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d’Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico
2016-01-01
Introduction The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. Methods 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Results Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS≤2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Conclusions Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size. PMID:26824672
Barca, Patrizio; Giannelli, Marco; Fantacci, Maria Evelina; Caramella, Davide
2018-06-01
Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.
Neuroanatomical Predictors of Awakening in Acutely Comatose Patients
Kowalski, Robert G.; Buitrago, Manuel M.; Duckworth, Josh; Chonka, Zachary D.; Puttgen, H. Adrian; Stevens, Robert D.; Geocadin, Romergryko G.
2016-01-01
Objective Lateral brain displacement has been associated with loss of consciousness and poor outcome in a range of acute neurologic disorders. We studied the association between lateral brain displacement and awakening from acute coma. Methods This prospective observational study included all new onset coma patients admitted to the Neurosciences Critical Care Unit (NCCU) over 12 consecutive months. Head computed tomography (CT) scans were analyzed independently at coma onset, after awakening, and at follow-up. Primary outcome measure was awakening, defined as the ability to follow commands before hospital discharge. Secondary outcome measures were discharge Glasgow Coma Scale (GCS), modified Rankin Scale, Glasgow Outcome Scale, and hospital and NCCU lengths of stay. Results Of the 85 patients studied, the mean age was 58 ± 16 years, 51% were female, and 78% had cerebrovascular etiology of coma. Fifty-one percent of patients had midline shift on head CT at coma onset and 43 (51%) patients awakened. In a multivariate analysis, independent predictors of awakening were younger age (odds ratio [OR] = 1.039, 95% confidence interval [CI] = 1.002–1.079, p = 0.040), higher GCS score at coma onset (OR = 1.455, 95% CI = 1.157–1.831, p = 0.001), nontraumatic coma etiology (OR = 4.464, 95% CI = 1.011–19.608, p = 0.048), lesser pineal shift on follow-up CT (OR = 1.316, 95% CI = 1.073–1.615, p = 0.009), and reduction or no increase in pineal shift on follow-up CT (OR = 11.628, 95% CI = 2.207–62.500, p = 0.004). Interpretation Reversal and/or limitation of lateral brain displacement are associated with acute awakening in comatose patients. These findings suggest objective parameters to guide prognosis and treatment in patients with acute onset of coma. PMID:25628166
Immediate breast reconstruction-impact on radiation management.
Shankar, Ravi A.; Nibhanupudy, J. Rao; Sridhar, Rajagopalan; Ashton, Cori; Goldson, Alfred L.
2003-01-01
Breast reconstruction is an option for women undergoing modified radical mastectomy due to a diagnosis of breast cancer. In certain patients, breast reconstruction is performed by insertion of a temporary tissue expander prior to the placement of permanent breast implants. Some of these patients, following mastectomy, may require chest wall irradiation to prevent loco regional relapse. The compatibility of radiation and tissue expanders placed in the chest wall is of major concern to the radiation oncologist. Clinically undetectable changes can occur in the tissue expander during the course of radiation therapy. This can lead to radiation treatment set-up changes, variation in tissue expansion resulting in unwanted cosmesis, and deviation from the prescribed radiation dose leading to over and/or under dosing of tumor burden. At Howard University hospital, a CT scan was utilized to evaluate the status of the temporary tissue expander during radiation treatment to enable us to prevent radiation treatment related complications resulting from dosimetric discrepancies. CT images of the tissue expander were obtained through the course of treatment. To avoid a 'geographic miss' the amount of fluid injected into the tissue expander was kept constant following patient's satisfaction with the size of the breast mound. The CT scans allowed better visualization of the prosthesis and its relation to the surrounding tumor bed. This technique ensured that anatomical changes occurring during radiation treatment, if any, were minimized. Repeated dosimetry evaluations showed no changes to the prescribed dose distribution. A CT of the reconstructed breast provides an important quality control. Further studies with greater number of patients are required for confirming this impact on radiation treatment. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 PMID:12749619
Ferrin, Maite; Vance, Alasdair
2014-12-01
Working memory (WM) deficits have been shown to be associated with core ADHD symptoms, worse academic achievement and peer-relationship problems. Internalizing symptoms, such as anxiety and depression, have also been associated with impaired WM performance. However, the association of anxiety and depression and WM performance remains unclear for children and adolescents with ADHD. Further, it is unknown how these comorbid conditions might affect WM performance in the two main ADHD subtypes. The association of anxiety and depression and the specific components of spatial (SWM) and verbal working memory (VWM) were examined in 303 children and adolescents with ADHD, combined type (ADHD-CT) and 77 ADHD, inattentive type (ADHD-IA) compared to 128 age- and gender-matched typically developing participants. The relationship between anxiety and depression and WM was assessed using multiple linear regression analyses and separate simple regression analyses. Higher levels of anxiety/depression were associated with (1) increased between-search errors in the typically developing participants alone, (2) a better strategy performance in the ADHD-CT group, and (3) a better spatial span performance in the ADHD-IA group. VWM was equally impaired in the ADHD-CT and ADHD-IA groups, independent of the levels of anxiety and depression. The results suggest that the effects of internalizing symptoms on WM differ in typically developing children and adolescents compared to those with ADHD. Further, high levels of anxiety and depression modified WM performance differently according to the specific ADHD subtypes. This might help explain contradictory findings observed in previous studies of mixed samples of participants with ADHD-CT and ADHD-IA.
Huehnerschulte, Tim Andreas; Angrisani, Nina; Rittershaus, Dina; Bormann, Dirk; Windhagen, Henning; Meyer-Lindenberg, Andrea
2011-01-01
In magnesium alloys, the components used modify the alloy properties. For magnesium implants in contact with bone, rare earths alloys are commonly examined. These were shown to have a higher corrosion resistance than other alloys and a high mechanical strength, but their exact composition is hard to predict. Therefore a reduction of their content could be favorable. The alloys ZEK100 and AX30 have a reduced content or contain no rare earths at all. The aim of the study was to investigate their in vivo degradation and to assess the suitability of the in vivo µCT for the examination of their corrosion. Implants were inserted in rabbit tibiae. Clinical examinations, X-rays and in vivo µCT scans were done regularly. Afterwards implants were analyzed with REM, electron dispersive X-ray (EDX), weighing and mechanical testing. The in vivo µCT is of great advantage, because it allows a quantification of the corrosion rate and qualitative 3D assessment of the corrosion morphology. The location of the implant has a remarkable effect on the corrosion rate. Due to its mechanical characteristics and its corrosion behavior, ZEK100 was judged to be suitable, while AX30, which displays favorable degradation behavior, has too little mechanical strength for applications in weight bearing bones. PMID:28879972
NASA Astrophysics Data System (ADS)
Cao, Liji; Peter, Jörg
2013-06-01
The adoption of axially oriented line illumination patterns for fluorescence excitation in small animals for fluorescence surface imaging (FSI) and fluorescence optical tomography (FOT) is being investigated. A trimodal single-photon-emission-computed-tomography/computed-tomography/optical-tomography (SPECT-CT-OT) small animal imaging system is being modified for employment of point- and line-laser excitation sources. These sources can be arbitrarily positioned around the imaged object. The line source is set to illuminate the object along its entire axial direction. Comparative evaluation of point and line illumination patterns for FSI and FOT is provided involving phantom as well as mouse data. Given the trimodal setup, CT data are used to guide the optical approaches by providing boundary information. Furthermore, FOT results are also being compared to SPECT. Results show that line-laser illumination yields a larger axial field of view (FOV) in FSI mode, hence faster data acquisition, and practically acceptable FOT reconstruction throughout the whole animal. Also, superimposed SPECT and FOT data provide additional information on similarities as well as differences in the distribution and uptake of both probe types. Fused CT data enhance further the anatomical localization of the tracer distribution in vivo. The feasibility of line-laser excitation for three-dimensional fluorescence imaging and tomography is demonstrated for initiating further research, however, not with the intention to replace one by the other.
Direct visualization of gastrointestinal tract with lanthanide-doped BaYbF5 upconversion nanoprobes.
Liu, Zhen; Ju, Enguo; Liu, Jianhua; Du, Yingda; Li, Zhengqiang; Yuan, Qinghai; Ren, Jinsong; Qu, Xiaogang
2013-10-01
Nanoparticulate contrast agents have attracted a great deal of attention along with the rapid development of modern medicine. Here, a binary contrast agent based on PAA modified BaYbF5:Tm nanoparticles for direct visualization of gastrointestinal (GI) tract has been designed and developed via a one-pot solvothermal route. By taking advantages of excellent colloidal stability, low cytotoxicity, and neglectable hemolysis of these well-designed nanoparticles, their feasibility as a multi-modal contrast agent for GI tract was intensively investigated. Significant enhancement of contrast efficacy relative to clinical barium meal and iodine-based contrast agent was evaluated via X-ray imaging and CT imaging in vivo. By doping Tm(3+) ions into these nanoprobes, in vivo NIR-NIR imaging was then demonstrated. Unlike some invasive imaging modalities, non-invasive imaging strategy including X-ray imaging, CT imaging, and UCL imaging for GI tract could extremely reduce the painlessness to patients, effectively facilitate imaging procedure, as well as rationality economize diagnostic time. Critical to clinical applications, long-term toxicity of our contrast agent was additionally investigated in detail, indicating their overall safety. Based on our results, PAA-BaYbF5:Tm nanoparticles were the excellent multi-modal contrast agent to integrate X-ray imaging, CT imaging, and UCL imaging for direct visualization of GI tract with low systemic toxicity. Copyright © 2013 Elsevier Ltd. All rights reserved.
A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology.
Figliuzzi, M; Mangano, F; Mangano, C
2012-07-01
Direct laser metal forming (DLMF) is a new technique which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. Modern computed tomography (CT) acquisition and 3D image conversion, combined with the DLMF process, allows the fabrication of custom-made, root-analogue implants (RAI), perfect copies of the radicular units that need replacing. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CT images of the residual non-restorable root of a right maxillary premolar were acquired and modified with specific software into a 3D model. From this model, a custom-made, root-analogue, DLMF implant was fabricated. Immediately after tooth extraction, the root-analogue implant was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the custom-made implant showed almost perfect functional and aesthetic integration. The possibility of fabricating custom-made, root-analogue DLMF implants opens new interesting perspectives for immediate placement of dental implants. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Campbell, Ian C.; Coudrillier, Baptiste; Mensah, Johanne; Abel, Richard L.; Ethier, C. Ross
2015-01-01
The lamina cribrosa (LC) is a tissue in the posterior eye with a complex trabecular microstructure. This tissue is of great research interest, as it is likely the initial site of retinal ganglion cell axonal damage in glaucoma. Unfortunately, the LC is difficult to access experimentally, and thus imaging techniques in tandem with image processing have emerged as powerful tools to study the microstructure and biomechanics of this tissue. Here, we present a staining approach to enhance the contrast of the microstructure in micro-computed tomography (micro-CT) imaging as well as a comparison between tissues imaged with micro-CT and second harmonic generation (SHG) microscopy. We then apply a modified version of Frangi's vesselness filter to automatically segment the connective tissue beams of the LC and determine the orientation of each beam. This approach successfully segmented the beams of a porcine optic nerve head from micro-CT in three dimensions and SHG microscopy in two dimensions. As an application of this filter, we present finite-element modelling of the posterior eye that suggests that connective tissue volume fraction is the major driving factor of LC biomechanics. We conclude that segmentation with Frangi's filter is a powerful tool for future image-driven studies of LC biomechanics. PMID:25589572
Enquobahrie, Daniel A; Sanchez, Sixto E; Muy-Rivera, Martin; Qiu, Chunfang; Zhang, Cuilin; Austin, Melissa A; Williams, Michelle A
2005-10-01
We examined the association between the hepatic lipase (LIPC) gene promoter polymorphism (-514C/T) and risk of preeclampsia among Peruvian women. We also evaluated whether this association is modified by maternal pre-pregnancy overweight status. Using a case control study design, 157 preeclampsia cases and 180 normotensive controls were enrolled in the study. Genotyping was conducted using PCR amplification, NlaIII enzyme digestion and gel electrophoresis. Logistic regression procedures were used to calculate adjusted odds ratios (ORs) and 95% confidence intervals (CI). After adjusting for confounding by maternal age, parity and pre-pregnancy body mass index (BMI), the relative risks of preeclampsia for women with LIPC -514CT and LIPC -514TT genotypes were 1.0 (95% CI 0.5-2.2) and 1.5 (95% CI 0.7-3.3) respectively, using women with LIPC -514CC genotype as a reference. Women who were both overweight and who had the LIPC -514TT genotype had a significant 3-fold increased risk of preeclampsia (Adj. OR:3.0 95% CI 1.3-6.8) as compared to those women who were not overweight and had the LIPC -514CC/CT genotype. In this study, we found that LIPC -514TT genotype and overweight status, when occurring together, were associated with a 3-fold increase in risk of preeclampsia among Peruvian women.
Matysiak-Brynda, Edyta; Bujak, Piotr; Augustin, Ewa; Kowalczyk, Agata; Mazerska, Zofia; Pron, Adam; Nowicka, Anna M
2018-01-18
One way to limit the negative effects of anti-tumor drugs on healthy cells is targeted therapy employing functionalized drug carriers. Here we present a biocompatible and stable nanoconjugate of transferrin anchored to Ag-In-Zn-S quantum dots modified with 11-mercaptoundecanoic acid (Tf-QD) as a drug carrier versus typical anticancer drug, doxorubicin. Detailed investigations of Tf-QD nanoconjugates without and with doxorubicin by fluorescence studies and cytotoxic measurements showed that the biological activity of both the transferrin and doxorubicin was fully retained in the nanoconjugate. In particular, the intercalation capabilities of free doxorubicin versus ctDNA remained essentially intact upon its binding to the nanoconjugate. In order to evaluate these capabilities, we studied the binding constant of doxorubicin attached to Tf-QDs with ctDNA as well as the binding site size on the ctDNA molecule. The binding constant slightly decreased compared to that of free doxorubicin while the binding site size, describing the number of consecutive DNA lattice residues involved in the binding, increased. It was also demonstrated that the QDs alone and in the form of a nanoconjugate with Tf were not cytotoxic towards human non-small cell lung carcinoma (H460 cell line) and the tumor cell sensitivity of the DOX-Tf-QD nanoconjugate was comparable to that of doxorubicin alone.
Rowan, Daniel J.; Tomatsu, Shunji; Grubb, Jeffrey H.; Haupt, Bisong; Montaño, Adriana M.; Oikawa, Hirotaka; Sosa, Catalina; Chen, Anping; Sly, William S.
2012-01-01
Mucopolysaccharidosis (MPS) type VII is a lysosomal storage disease caused by deficiency of the lysosomal enzyme β-glucuronidase (GUS), leading to accumulation of glycosaminoglycans (GAGs). Enzyme replacement therapy (ERT) effectively clears GAG storage in the viscera. Recent studies showed that a chemically modified form of GUS (PerT-GUS), which escaped clearance by mannose 6-phosphate and mannose receptors and showed prolonged circulation, reduced CNS storage more effectively than native GUS. Clearance of storage in bone has been limited due to the avascularity of the growth plate. To evaluate the effectiveness of long-circulating PerT-GUS in reducing the skeletal pathology, we treated MPS VII mice for 12 weeks beginning at 5 weeks of age with PerT-GUS or native GUS and used micro-CT, radiographs, and quantitative histopathological analysis for assessment of bones. Micro-CT findings showed PerT-GUS treated mice had a significantly lower BMD. Histopathological analysis also showed reduced storage material and a more organized growth plate in PerT-GUS treated mice compared with native GUS treated mice. Long term treatment with PerT-GUS from birth up to 57 weeks also significantly improved bone lesions demonstrated by micro-CT, radiographs and quantitative histopathological assay. In conclusion, long-circulating PerT-GUS provides a significant impact to rescue of bone lesions and CNS involvement. PMID:22902520
Karimi Shervedani, Reza; Mirhosseini, Hadiseh; Samiei Foroushani, Marzieh; Torabi, Mostafa; Rahsepar, Fatemeh Rahnemaye; Norouzi-Barough, Leila
2018-02-01
Immobilization of methotrexate (MTX) anticancer drug onto the graphene surface is reported through three methods, including either covalent linkage via (a) EDC/NHS organic activators and (b) electrografting of MTX diazonium salt, or (c) noncovalent bonding, resulting in three different systems. To evaluate the interaction ability of the immobilized MTX with biological species, calf thymus DNA (ctDNA), mouse 4T1 breast tumor, and Human foreskin fibroblast (hFF) cells as models of the primary intracellular target of anticancer drugs, cancer and normal cells, respectively, are examined. The features of the constructed systems and their interactions with ctDNA are followed by surface analysis techniques and electrochemical methods. The results indicate that (i) the amount of the immobilized MTX on the graphene surface is affected by type of the immobilization method; and a maximum value of (Γ=9.3±0.9pmolcm -2 ) is found via electrografting method, (ii) graphene-modified-MTX has high affinity for ctDNA in a wide dynamic range of concentrations, and (iii) the nature of the interaction is of electrostatic and/or hydrogen bonding type, formed most probably between OH, NH and CO groups of MTX and different DNA functions. Finally, electrochemical impedance spectroscopy results approved the high affinity of the systems for 4T1 cancer cells. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Park, Bumwoo; Furlan, Alessandro; Patil, Amol; Bae, Kyongtae T.
2010-03-01
Pulmonary embolism (PE) is a medical condition defined as the obstruction of pulmonary arteries by a blood clot, usually originating in the deep veins of the lower limbs. PE is a common but elusive illness that can cause significant disability and death if not promptly diagnosed and effectively treated. CT Pulmonary Angiography (CTPA) is the first line imaging study for the diagnosis of PE. While clinical prediction rules have been recently developed to associate short-term risks and stratify patients with acute PE, there is a dearth of objective biomarkers associated with the long-term prognosis of the disease. Clot (embolus) burden is a promising biomarker for the prognosis and recurrence of PE and can be quantified from CTPA images. However, to our knowledge, no study has reported a method for segmentation and measurement of clot from CTPA images. Thus, the purpose of this study was to develop a semi-automated method for segmentation and measurement of clot from CTPA images. Our method was based on Modified Seeded Region Growing (MSRG) algorithm which consisted of two steps: (1) the observer identifies a clot of interest on CTPA images and places a spherical seed over the clot; and (2) a region grows around the seed on the basis of a rolling-ball process that clusters the neighboring voxels whose CT attenuation values are within the range of the mean +/- two standard deviations of the initial seed voxels. The rollingball propagates iteratively until the clot is completely clustered and segmented. Our experimental results revealed that the performance of the MSRG was superior to that of the conventional SRG for segmenting clots, as evidenced by reduced degrees of over- or under-segmentation from adjacent anatomical structures. To assess the clinical value of clot burden for the prognosis of PE, we are currently applying the MSRG for the segmentation and volume measurement of clots from CTPA images that are acquired in a large cohort of patients with PE in an on-going NIH-sponsored clinical trial.
Rose, Fabrice; Wern, Jeanette Erbo; Gavins, Francesca; Andersen, Peter; Follmann, Frank; Foged, Camilla
2018-02-10
Induction of mucosal immunity with vaccines is attractive for the immunological protection against pathogen entry directly at the site of infection. An example is infection with Chlamydia trachomatis (Ct), which is the most common sexually transmitted infection in the world, and there is an unmet medical need for an effective vaccine. A vaccine against Ct should elicit protective humoral and cell-mediated immune (CMI) responses in the genital tract mucosa. We previously designed an antibody- and CMI-inducing adjuvant based on poly(dl-lactic-co-glycolic acid) (PLGA) nanoparticles modified with the cationic surfactant dimethyldioctadecylammonium bromide and the immunopotentiator trehalose-6,6'-dibehenate. Here we show that immunization with these lipid-polymer hybrid nanoparticles (LPNs) coated with the mucoadhesive polymer chitosan enhances mucosal immune responses. Glycol chitosan (GC)-modified LPNs were engineered using an oil-in-water single emulsion solvent evaporation method. The nanoparticle design was optimized in a highly systematic way by using a quality-by-design approach to define the optimal operating space and to gain maximal mechanistic information about the GC coating of the LPNs. Cryo-transmission electron microscopy revealed a PLGA core coated with one or several concentric lipid bilayers. The GC coating of the surface was identified as a saturable, GC concentration-dependent increase in particle size and a reduction of the zeta-potential, and the coating layer could be compressed upon addition of salt. Increased antigen-specific mucosal immune responses were induced in the lungs and the genital tract with the optimized GC-coated LPN adjuvant upon nasal immunization of mice with the recombinant Ct fusion antigen CTH522. The mucosal responses were characterized by CTH522-specific IgG/IgA antibodies, together with CTH522-specific interferon γ-producing Th1 cells. This study demonstrates that mucosal administration of CTH522 adjuvanted with chitosan-coated LPNs represents a promising strategy to modulate the magnitude of mucosal vaccine responses. Copyright © 2017 Elsevier B.V. All rights reserved.
Significance of large vessel intracranial occlusion causing acute ischemic stroke and TIA.
Smith, Wade S; Lev, Michael H; English, Joey D; Camargo, Erica C; Chou, Maggie; Johnston, S Claiborne; Gonzalez, Gilberto; Schaefer, Pamela W; Dillon, William P; Koroshetz, Walter J; Furie, Karen L
2009-12-01
Acute ischemic stroke due to large vessel occlusion (LVO)-vertebral, basilar, carotid terminus, middle and anterior cerebral arteries-likely portends a worse prognosis than stroke unassociated with LVO. Because little prospective angiographic data have been reported on a cohort of unselected patients with stroke and with transient ischemic attack, the clinical impact of LVO has been difficult to quantify. The Screening Technology and Outcome Project in Stroke Study is a prospective imaging-based study of stroke outcomes performed at 2 academic medical centers. Patients with suspected acute stroke who presented within 24 hours of symptom onset and who underwent multimodality CT/CT angiography were approached for consent for collection of clinical data and 6-month assessment of outcome. Demographic and clinical variables and 6-month modified Rankin Scale scores were collected and combined with blinded interpretation of the CT angiography data. The OR of each variable, including occlusion of intracranial vascular segment in predicting good outcome and 6-month mortality, was calculated using univariate and multivariate logistic regression. Over a 33-month period, 735 patients with suspected stroke were enrolled. Of these, 578 were adjudicated as stroke and 97 as transient ischemic attack. Among patients with stroke, 267 (46%) had LVO accounting for the stroke and 13 (13%) of patients with transient ischemic attack had LVO accounting for transient ischemic attack symptoms. LVO predicted 6-month mortality (OR, 4.5; 95% CI, 2.7 to 7.3; P<0.001). Six-month good outcome (modified Rankin Scale score
Wang, Q; Yang, Y; Fei, Q; Li, D; Li, J J; Meng, H; Su, N; Fan, Z H; Wang, B Q
2017-06-06
Objective: To build a three-dimensional finite element models of a modified posterior cervical single open-door laminoplasty with short-segmental lateral mass screws fusion. Methods: The C(2)-C(7) segmental data were obtained from computed tomography (CT) scans of a male patient with cervical spondylotic myelopathy and spinal stenosis.Three-dimensional finite element models of a modified cervical single open-door laminoplasty (before and after surgery) were constructed by the combination of software package MIMICS, Geomagic and ABAQUS.The models were composed of bony vertebrae, articulating facets, intervertebral disc and associated ligaments.The loads of moments 1.5Nm at different directions (flexion, extension, lateral bending and axial rotation)were applied at preoperative model to calculate intersegmental ranges of motion.The results were compared with the previous studies to verify the validation of the models. Results: Three-dimensional finite element models of the modified cervical single open- door laminoplasty had 102258 elements (preoperative model) and 161 892 elements (postoperative model) respectively, including C(2-7) six bony vertebraes, C(2-3)-C(6-7) five intervertebral disc, main ligaments and lateral mass screws.The intersegmental responses at the preoperative model under the loads of moments 1.5 Nm at different directions were similar to the previous published data. Conclusion: Three-dimensional finite element models of the modified cervical single open- door laminoplasty were successfully established and had a good biological fidelity, which can be used for further study.
NASA Astrophysics Data System (ADS)
Zhao, Yixin; Xue, Shanbin; Han, Songbai; Chen, Zhongwei; Liu, Shimin; Elsworth, Derek; He, Linfeng; Cai, Jianchao; Liu, Yuntao; Chen, Dongfeng
2017-07-01
Capillary imbibition in variably saturated porous media is important in defining displacement processes and transport in the vadose zone and in low-permeability barriers and reservoirs. Nonintrusive imaging in real time offers the potential to examine critical impacts of heterogeneity and surface properties on imbibition dynamics. Neutron radiography is applied as a powerful imaging tool to observe temporal changes in the spatial distribution of water in porous materials. We analyze water imbibition in both homogeneous and heterogeneous low-permeability sandstones. Dynamic observations of the advance of the imbibition front with time are compared with characterizations of microstructure (via high-resolution X-ray computed tomography (CT)), pore size distribution (Mercury Intrusion Porosimetry), and permeability of the contrasting samples. We use an automated method to detect the progress of wetting front with time and link this to square-root-of-time progress. These data are used to estimate the effect of microstructure on water sorptivity from a modified Lucas-Washburn equation. Moreover, a model is established to calculate the maximum capillary diameter by modifying the Hagen-Poiseuille and Young-Laplace equations based on fractal theory. Comparing the calculated maximum capillary diameter with the maximum pore diameter (from high-resolution CT) shows congruence between the two independent methods for the homogeneous silty sandstone but less effectively for the heterogeneous sandstone. Finally, we use these data to link observed response with the physical characteristics of the contrasting media—homogeneous versus heterogeneous—and to demonstrate the sensitivity of sorptivity expressly to tortuosity rather than porosity in low-permeability sandstones.
Ronda, Jocelyn; Gaydos, Charlotte A; Perin, Jamie; Tabacco, Lisa; Coleman, Jenell; Trent, Maria
2018-06-04
Mycoplasma genitalium (MG) is a common sexually transmitted infection (STI) but there are limited strategies to identify individuals at risk of MG. Previously a sex risk quiz was used to predict STIs including Chlamydia trachomatis (CT), Neisseria gonorrhoeae (GC), and/or Trichomonas vaginalis (TV). The original quiz categorized individuals ≤25 years old as at risk of STIs, but the Centers for Disease Control identifies females <25 years old as at risk of STIs. In this study, the quiz was changed to categorize females <25 years old as high risk. The objective was to determine if the age-modified risk quiz predicted MG infection. A cross-sectional analysis of a prospective longitudinal study was performed including female adolescents and young adults (AYA) evaluated in multiple outpatient clinics. Participants completed an age-modified risk quiz about sexual practices. Scores ranged from 0 to 10 and were categorized as low-risk (0-3), medium-risk (4-7), and high-risk (8-10) based upon the STI prevalence for each score. Vaginal and/or endocervical specimens were tested for MG, TV, CT, and GC using the Aptima Gen-Probe nucleic amplification test. There were 693 participants. Most participants reported having 0-1 sexual partners in the last 90 days (91%) and inconsistent condom use (84%). Multivariable logistic regression analysis controlling for race, education, and symptom status demonstrated that a medium-risk score predicted MG infection among AYA <25 years old (adjusted OR 2.56 [95% CI 1.06-6.18]). A risk quiz may be useful during clinical encounters to identify AYA at risk of MG.
Development of a timing detector for the TOTEM experiment at the LHC
NASA Astrophysics Data System (ADS)
Minafra, Nicola
2017-09-01
The upgrade program of the TOTEM experiment will include the installation of timing detectors inside vertical Roman Pots to allow the reconstruction of the longitudinal vertex position in the presence of event pile-up in high- β^{\\ast} dedicated runs. The small available space inside the Roman Pot, optimized for high-intensity LHC runs, and the required time precision led to the study of a solution using single crystal CVD diamonds. The sensors are read out using fast low-noise front-end electronics developed by the TOTEM Collaboration, achieving a signal-to-noise ratio larger than 20 for MIPs. A prototype was designed, manufactured and tested during a test beam campaign, proving a time precision below 100ps and an efficiency above 99%. The geometry of the detector has been designed to guarantee uniform occupancy in the expected running conditions keeping, at the same time, the number of channels below 12. The read-out electronics was developed during an extensive campaign of beam tests dedicated first to the characterization of existing solution and then to the optimization of the electronics designed within the Collaboration. The detectors were designed to be read out using the SAMPIC chip, a fast sampler designed specifically for picosecond timing measurements with high-rate capabilities; later, a modified version was realized using the HPTDC to achieve the higher trigger rates required for the CT-PPS experiment. The first set of prototypes was successfully installed and tested in the LHC in November 2015; moreover the detectors modified for CT-PPS are successfully part of the global CMS data taking since October 2016.
A suggested technique for the application of the cone beam computed tomography periapical index
Esposito, S; Cardaropoli, M; Cotti, E
2011-01-01
Objectives Cone beam CT (CBCT) produces undistorted three-dimensional (3D) images of the maxillofacial region with a radiation dosage lower than conventional CT. The periapical index score (PAI) is commonly used to follow up the lesions in the bone using periapical radiographs. Recently, a new PAI based on CBCT was introduced (CBCT-PAI). The aim of this technical report is to present a modified reproducible method to assess the CBCT-PAI. Methods CBCT was used to evaluate a periapical bone lesion observed in the area of tooth number 13 before treatment and 2 years after treatment. The modified CBCT-PAI was applied to both the examinations to measure the lesion. The dimensional analysis of the lesion was performed in each plane, assessing three fixed and reproducible dimensions: mesiodistal (M-D), buccolingual (B-L) and coronoapical (C-A). The images were evaluated by three mutually independent examiners. Data were collected and reported in a chart. The results were compared with each other and with the PAI score from the periapical radiographs. Results The three observers reported the same measurements of the lesion for each plane. The CBCT-PAI follow-up showed a reduction of the size of the lesion (5D vs 4D) but also an increase in the erosion of the buccal cortical plate. The comparison of CBCT-PAI with classic PAI showed the first method to be more precise. Conclusions This technical report shows how the CBCT-PAI can be applied to the CBCT exam of a periapical lesion in a reproducible way. PMID:22065800
Patient‐specific CT dosimetry calculation: a feasibility study
Xie, Huchen; Cheng, Jason Y.; Ning, Holly; Zhuge, Ying; Miller, Robert W.
2011-01-01
Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of “standard man”. Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient‐specific CT dosimetry. A radiation treatment planning system was modified to calculate patient‐specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose‐volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi‐empirical, measured correction‐based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point‐by‐point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%–20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient‐specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation. PACS numbers: 87.55.D‐, 87.57.Q‐, 87.53.Bn, 87.55.K‐ PMID:22089016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harding, Scott, A; Tsai, Chung-jui; Lindroth, Richard, L
The project set out to use comparative (genotype and treatment) and transgenic approaches to investigate the determinants of condensed tannin (CT) accrual and chemical variability in Populus. CT type and amount are thought to effect the decomposition of plant detritus in the soil, and thereby the sequestering of carbon in the soil. The stated objectives were: 1. Genome-wide transcriptome profiling (microarrays) to analyze structural gene, transcription factor and metabolite control of CT partitioning; 2. Transcriptomic (microarray) and chemical analysis of ontogenetic effects on CT and PG partitioning; and 3. Transgenic manipulation of flavonoid biosynthetic pathway genes to modify the controlmore » of CT composition. Objective 1: A number of approaches for perturbing CT content and chemistry were tested in Objective 1, and those included nitrogen deficit, leaf wounding, drought, and salicylic acid spraying. Drought had little effect on CTs in the genotypes we used. Plants exhibited unpredictability in their response to salicylic acid spraying, leading us to abandon its use. Reduced plant nitrogen status and leaf wounding caused reproducible and magnitudinally striking increases in leaf CT content. Microarray submissions to NCBI from those experiments are the following: GSE ID 14515: Comparative transcriptomics analysis of Populus leaves under nitrogen limitation: clone 1979. Public on Jan 04, 2010; Contributor(s) Harding SA, Tsai C GSE ID 14893: Comparative transcriptomics analysis of Populus leaves under nitrogen limitation: clone 3200. Public on Feb 19, 2009; Contributor(s) Harding SA, Tsai C GSE ID 16783 Wound-induced gene expression changes in Populus: 1 week; clone RM5. Status Public on Dec 01, 2009; Contributor(s) Harding SA, Tsai C GSE ID 16785 Wound-induced gene expression changes in Populus: 90 hours; clone RM5 Status Public on Dec 01, 2009; Contributor(s) Harding SA, Tsai C Although CT amount changed in response to treatments, CT composition was essentially conserved. Overall phenylpropanoid composition exhibited changes due to large effects on phenolic glycosides containing a salicin moiety. There were no effects on lignin content. Efforts to publish this work continue, and depend on additional data which we are still collecting. This ongoing work is expected to strengthen our most provocative metabolic profiling data which suggests as yet unreported links controlling the balance between the two major leaf phenylpropanoid sinks, the CTs and the salicin-PGs. Objective 2: Ontogenic effects on leaf CT accrual and phenylpropanoid complexity (Objective 2) have been reported in the past and we contributed two manuscripts on how phenylpropanoid sinks in roots and stems could have an increasing effect on leaf CT as plants grow larger and plant proportions of stem, root and leaf change. Tsai C.-J., El Kayal W., Harding S.A. (2006) Populus, the new model system for investigating phenylpropanoid complexity. International Journal of Applied Science and Engineering 4: 221-233. We presented evidence that flavonoid precursors of CT rapidly decline in roots under conditions that favor CT accrual in leaves. Harding SA, Jarvie MM, Lindroth RL, Tsai C-J (2009) A comparative analysis of phenylpropanoid metabolism, N utilization and carbon partitioning in fast- and slow-growing Populus hybrid clones. Journal of Experimental Botany. 60:3443-3452. We presented evidence that nitrogen delivery to leaves as a fraction of nitrogen taken up by the roots is lower in high leaf CT genotypes. We presented a hypothesis from our data that N was sequestered in proportion to lignin content in stem tissues. Low leaf N content and high leaf CT in genotypes with high stem lignin was posited to be a systemic outcome of N demand in lignifiying stem tissues. Thereby, stem lignin and leaf CT accrual might be systemically linked, placing control of leaf phenylpropanoids under systemic rather than solely organ specific determinants. Analyses of total structural and non-structural carbohydrates contributed to the model presented. Harding SA, Xue L, Du L, Nyamdari B, Sykes R, Davis M, Lindroth RL, Tsai CJ (submitted March 2013) Condensed tannin biosynthesis in leaves conditions carbon use, defense and growth in Populus. (Invited submission to Tree Physiology) MS abstract: Condensed tannins (CT) are flavonoid end products that can comprise a large fraction of leaf, bark and root biomass in Populus species. CT accrual was investigated in relation to metabolic carbon and nitrogen use in young leaves and shoot tips (ST) where CT biosynthesis was most active. A slow-growing genotype (SG) and a fast-growing genotype (FG) were compared. Both genotypes exhibited the capacity to accrue similarly large reserves of salicortin a phenolic glycoside (PG), but the slow-growing line also produced CT. PG accrual was developmentally delayed in the slow-growing line, SG. Irrigation with low-N nutrients promoted PG accrual in FG plants, but PG accrual was suspended in CT-producing SG plants. In addition, the low C:N amide asparagine accumulated and glucose was depleted in ST and expanding leaves of SG plants. The monoamine phenylethylamine (PEA) was abundant in SG leaves and absent in FG leaves. Leaf metabolite and gene expression differences were observed between SG and FG that would be expected to impinge upon glycolysis, acetyl-CoA production and flavonoid production. A model that integrates PEA with those activities and CT accrual was developed. Briefly, the data support a model in which flavonoid biosynthesis depleted the acetyl-CoA pool, thereby promoting glycolytic and shikimic pathway fluxes in SG plants. PEA results from decarboxylation of the shikimic pathway end-product phenylalanine, and is proposed to have facilitated CT polymerization, thereby promoting the continued biosynthesis of flavonoid CT precursors in SG leaves. The leaf differentials described here were absent in young roots, as was PEA. The potential contribution of PEA to CT polymerization constituted a metabolic carbon drain in developing leaves that was not observed in the roots. We propose that PEA, in addition to other factors, including flavonoid pathway Myb transcription factors, is an important contributor to carbon management and plant defense in Populus. Objective 3: From work related to the first two objectives, it appeared that CT chemistry, at least in terms of the proportions of mono, di and tri hydroxylation at the phenylpropanoid-derived B-ring, changed little if at all when CT accrual per unit time was increased. A large number of transgenic Populus plants with alterations in the expression of flavonoid pathway genes and the potential to produce B-ring, chemically altered CT were generated during the project. Transgenic lines of Populus tremula Michx. Populus alba L. clone 717-1B4, a low CT producer, were produced that over- or under-express several mid and late flavonoid pathway genes including dihydroxyflavonol reductase (DFR-2 isoforms), leucoanthocyanidin reductase (LAR-3 isoforms), anthocyanidin reductase (ANR-2 isoforms), flavonol synthase (FLS-2 isoforms). A large number of additional transformation constructs (chalcone synthases, flavone synthases, and flavanol hydroxylases) were developed that failed to result in transgenic plants. We have purified CT from several of the successful lines and have obtained evidence from pyrolysis GC-MS that CT chemical composition was altered in transgenic lines harboring overexpression constructs for one of the two DFR isoforms. We have also observed increased CT levels in leaves of those lines, but the increases vary substantially in magnitude from experiment to experiment which has led to ongoing efforts to understand the variation before attempting to publish the findings. Preliminary results from some of the transgenic work were presented: An C*, Luo K, El Kayal W, Harding SA, Tsai C-J (2009) Transgenic manipulation of condensed tannins in Populus. IUFRO Tree Biotechnology Conference, Whistler, BC, Canada Work on the design of some of the constructs for the CT transgenics work has been published: Luo K, Harding SA, Tsai C-J (2008) A modified T-vector for simplified assembly of hairpin RNAi constructs. Biotechnology Letters 30: 1271-1274. DOE support from this project was also acknowledged in a book chapter: Douglas CJ, Ehlting J, Harding SA (2009) Phenylpropanoid and Phenolic Metabolism in Populus: Gene Family Structure and Comparative and Functional Genomics In Joshi, C.P., and S.P. DiFazio (eds). Genetics, Genomics and Breeding of Crop Plants: Poplar. Science Publishers, Enfield, New Hampshire. Pp. 304-326 Other work directly related to and supported in part by this project include: Qin H, Feng T, Harding SA, Tsai C-J, Zhang S (2008) An efficient method to identify differentially expressed genes in microarray experiments. Bioinformatics 24: 1583-1589. Tsai C-J, Ranjan P, DiFazio SP, Tuskan GA, Johnson V (2011) Poplar genome microarrays. In: Joshi CP, DiFazio SP and Kole C (eds), Genetics, Genomics and Breeding of Poplars. Science Publishers, Enfield, NH. pp. 112-127. Street N, Tsai C-J (2010) Populus resources and bioinformatics. In: Jansson S, Bhalerao R, and Groover AT (eds), Genetics and Genomics of Populus. Plant Genetics and Genomics: Crops and Models book series. Springer, New York, pp. 135-152.« less
Srivastava, Priyanka; Kapoor, Rakesh; Mittal, Rama D
2013-02-01
Matrix metalloproteinases (MMPs) are expressed in melanocytes and their overexpression has been linked to tumor development, progression, and metastasis. At the genetic level, following functional promoter polymorphisms are known to modify the gene transcription: -1306 C > T, -735 C > T in MMP2, and 799 C > T in MMP8 gene. Hence we hypothesize that functional polymorphisms in the 2 MMP SNPs in promoter region may modulate the risk for bladder cancer (BC) progression in North Indian population. Genotyping for these polymorphisms were done in a group of 200 BC and 200 age matched, similar ethnicity unrelated healthy controls using PCR-based methods. Two-sided χ(2), Cox-regression was utilized to evaluate the associations between genotype and various clinical and epidemiologic factors. Multivariate analyses were conducted using logistic regression, adjusting for known BC confounders such as age and gender. Survival analysis was done using the Kaplan-Meier method and differences in survival were assessed using the log rank test. Individuals with MMP2 (-1306) TT genotype as well as T allele were at higher risk of BC (P, 0.042; OR, 2.85; P, 0.001; OR, 1.76). This effect was even more apparent in case of CT+TT (P < 0.001; OR, 2.61). In MMP2 (735), CT+TT demonstrated significant risk (P, 0.034; OR, 1.66). In MMP8 (799), reduced risk was observed with TT genotype (P, 0.006; OR, 0.27). Haplotype analysis showed that individuals with haplotype 735C-1306T and 735T-1306C were at 1.9- and 1.5-fold higher risk. MMP2 -1306CC in combination with MMP8 799CT genotype showed protective effect. The genotype CT and CT+TT of MMP2 1306C > T were associated with high risk of recurrence in BCG treated patients (HR, 4.32; P, 0.006 and HR, 2.06; P, 0.047) thus showing reduced recurrence free survival (CT+TT/CC = 34/45 months; log rank P, 0.039). Our data suggested that variant allele of MMP2 1306C > T was associated with high risk of tumor recurrence and reduced recurrence free survival in superficial BC patients. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Z; Xia, P; Djemil, T
Purpose: To evaluate the impact of a commercial orthopedic metal artifact reduction (O-MAR) algorithm on CT image quality and dose calculation for patients with spinal prostheses near spinal tumors. Methods: A CT electron density phantom was scanned twice: with tissue-simulating inserts only, and with a titanium insert replacing solid water. A patient plan was mapped to the phantom images in two ways: with the titanium inside or outside of the spinal tumor. Pinnacle and Eclipse were used to evaluate the dosimetric effects of O-MAR on 12-bit and 16-bit CT data, respectively. CT images from five patients with spinal prostheses weremore » reconstructed with and without O-MAR. Two observers assessed the image quality improvement from O-MAR. Both pencil beam and Monte Carlo dose calculation in iPlan were used for the patient study. The percentage differences between non-OMAR and O-MAR datasets were calculated for PTV-min, PTV-max, PTV-mean, PTV-V100, PTV-D90, OAR-V10Gy, OAR-max, and OAR-D0.1cc. Results: O-MAR improved image quality but did not significantly affect the dose distributions and DVHs for both 12-bit and 16- bit CT phantom data. All five patient cases demonstrated some degree of image quality improvement from O-MAR, ranging from small to large metal artifact reduction. For pencil beam, the largest discrepancy was observed for OARV-10Gy at 5.4%, while the other seven parameters were ≤0.6%. For Monte Carlo, the differences between non-O-MAR and O-MAR datasets were ≤3.0%. Conclusion: Both phantom and patient studies indicated that O-MAR can substantially reduce metal artifacts on CT images, allowing better visualization of the anatomical structures and metal objects. The dosimetric impact of O-MAR was insignificant regardless of the metal location, image bit-depth, and dose calculation algorithm. O-MAR corrected images are recommended for radiation treatment planning on patients with spinal prostheses because of the improved image quality and no need to modify current dose constraints. This work was supported by a research grant from Philips Healthcare. Paul Klahr is an employee of Philips Healthcare.« less
Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment.
Meng, Bowen; Pratx, Guillem; Xing, Lei
2011-12-01
Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT∕CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. In this work, we accelerated the Feldcamp-Davis-Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT∕CT reconstruction algorithm. Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10(-7). Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. An ultrafast, reliable and scalable 4D CBCT∕CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment.
Oh, Sang Young; Lee, Minho; Seo, Joon Beom; Kim, Namkug; Lee, Sang Min; Lee, Jae Seung; Oh, Yeon Mok
2017-01-01
A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT). Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method ( r -values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942). The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT) parameters using the Pearson's correlation test. The mean extents of low-attenuation area (LAA), E1 (<1.5 mm), E2 (<7 mm), E3 (<15 mm), and E4 (≥15 mm) were 25.9%, 3.0%, 11.4%, 7.6%, and 3.9%, respectively, at the inspiratory CT, and 15.3%, 1.4%, 6.9%, 4.3%, and 2.6%, respectively at the expiratory CT. The extents of LAA, E2, E3, and E4 were found to be significantly correlated with the PFT parameters ( r =-0.53, -0.43, -0.48, and -0.25), with forced expiratory volume in 1 second (FEV 1 ; -0.81, -0.62, -0.75, and -0.40), and with diffusing capacity of the lungs for carbon monoxide (cDLco), respectively. The fraction of emphysema that shifted to the smaller subgroup showed a significant correlation with FEV 1 , cDLco, forced expiratory flow at 25%-75% of forced vital capacity, and residual volume (RV)/total lung capacity ( r =0.56, 0.73, 0.40, and -0.58). A detailed assessment of the size variation and collapse of emphysema holes may be useful for understanding the dynamic collapse of emphysema and its functional relation.
Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment
Meng, Bowen; Pratx, Guillem; Xing, Lei
2011-01-01
Purpose: Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT/CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. Methods: In this work, we accelerated the Feldcamp–Davis–Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT/CT reconstruction algorithm. Results: Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10−7. Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. Conclusions: An ultrafast, reliable and scalable 4D CBCT/CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment. PMID:22149842
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsalafoutas, Ioannis A.; Varsamidis, Athanasios; Thalassinou, Stella
Purpose: To investigate the utility of the nested polymethylacrylate (PMMA) phantom (which is available in many CT facilities for CTDI measurements), as a tool for the presentation and comparison of the ways that two different CT automatic exposure control (AEC) systems respond to a phantom when various scan parameters and AEC protocols are modified.Methods: By offsetting the two phantom's components (the head phantom and the body ring) half-way along their longitudinal axis, a phantom with three sections of different x-ray attenuation was created. Scan projection radiographs (SPRs) and helical scans of the three-section phantom were performed on a Toshiba Aquilionmore » 64 and a Philips Brilliance 64 CT scanners, with different scan parameter selections [scan direction, pitch factor, slice thickness, and reconstruction interval (ST/RI), AEC protocol, and tube potential used for the SPRs]. The dose length product (DLP) values of each scan were recorded and the tube current (mA) values of the reconstructed CT images were plotted against the respective Z-axis positions on the phantom. Furthermore, measurements of the noise levels at the center of each phantom section were performed to assess the impact of mA modulation on image quality.Results: The mA modulation patterns of the two CT scanners were very dissimilar. The mA variations were more pronounced for Aquilion 64, where changes in any of the aforementioned scan parameters affected both the mA modulations curves and DLP values. However, the noise levels were affected only by changes in pitch, ST/RI, and AEC protocol selections. For Brilliance 64, changes in pitch affected the mA modulation curves but not the DLP values, whereas only AEC protocol and SPR tube potential selection variations affected both the mA modulation curves and DLP values. The noise levels increased for smaller ST/RI, larger weight category AEC protocol, and larger SPR tube potential selection.Conclusions: The nested PMMA dosimetry phantom can be effectively utilized for the comprehension of CT AEC systems performance and the way that different scan conditions affect the mA modulation patterns, DLP values, and image noise. However, in depth analysis of the reasons why these two systems exhibited such different behaviors in response to the same phantom requires further investigation which is beyond the scope of this study.« less
NASA Astrophysics Data System (ADS)
Koybasi, Ozhan; Mishra, Pankaj; St. James, Sara; Lewis, John H.; Seco, Joao
2014-02-01
For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of ‘treatment’ with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for the patient with relatively regular breathing. We have demonstrated that proton therapy using the pre-treatment 4D-CT based ITV method can lead to significant under-dosage of the tumor, highlighting the need for daily customization to generate a target volume that represents tumor positions during the treatment more accurately.
Carbonate system parameters and anthropogenic CO2 in the North Aegean Sea during October 2013
NASA Astrophysics Data System (ADS)
Krasakopoulou, E.; Souvermezoglou, E.; Giannoudi, L.; Goyet, C.
2017-10-01
Data of AT (total alkalinity) and CT (total inorganic carbon) collected during October 2013, on a N-S transect crossing the North of Lemnos basin allowed to identify the peculiarities of the CO2 system in the North Aegean Sea and estimate the anthropogenic CO2 (CANT) concentrations. Extremely high concentrations of AT and CT were recorded in the upper layer of the North Aegean reflecting the high loads of AT and CT by the brackish BSW (Black Sea Water) outflowing through the Dardanelles strait and by the rivers runoff. Both AT and CT exhibit strong negative linear correlation with salinity in the upper layer (0-20 m). Investigation of the AT-S relationship along with the salinity adjustment of AT revealed excess alkalinity throughout the water column in relation to the surface waters implying a possible occurrence of non-carbonate alkalinity inputs as well as of other processes that take place probably over the extended shelves and contribute to the alkalinity surplus. The intermediate layer occupied by the Modified Levantine Intermediate Water (MLIW) mass exhibits the lowest CT and AT concentrations, while rather elevated AT and CT concentrations characterize the North Aegean Deep Water (NAgDW) mass filling the deep layer of the North of Lemnos basin linked to previous dense water formation episodes. High anthropogenic CO2 content was detected at intermediate and deep layers of the North Aegean reflecting the effective transportation of the absorbed atmospheric CO2 from the surface to the deeper waters via the dense water formation episodes. The MLIW layer is more affected by the penetration of CANT than the NAgDW that fills the deep part of the basin. The observed variability of CANT distribution reflects the influence of the intensity of dense water formation events, of the different θ/S properties of the newly formed dense waters as well as of the diverse submarine pathways followed by the cascading dense waters. The invasion of CANT has lead to more acidic conditions and to lower saturation degree of calcium carbonate in relation to the preindustrial era. The findings of this study provide baseline information about the carbonate system properties of the North Aegean and highlight its active role in sequestering and storing anthropogenic CO2.
PM10 emissions from aggregate fractions of an Entic Haplustoll under two contrasting tillage systems
NASA Astrophysics Data System (ADS)
Mendez, Mariano J.; Aimar, Silvia B.; Buschiazzo, Daniel E.
2015-12-01
Tillage systems affect physical and chemical properties of soils modifying its aggregation. How changes of the aggregate size distribution affect the capacity of the soil to emit fine particulate matter (PM10) to the atmosphere during wind erosion processes, is a less investigated issue. In order to answer this question, PM10 emissions from an Entic Haplustoll submitted to 25 years of continuous conventional tillage (LC) and no-till (NT) were analyzed. Soil samples were sieved with a rotary sieve in order to determine the aggregate size distribution (fractions : <0.42 mm, 0.42-0.84 mm, 0.84-2 mm, 2-6.4 mm, 6.4-19.2 mm, and >19.2 mm), the dry aggregate stability (DAS) and the erodible fraction (EF). The organic matter contents (OM), the particle size composition and the PM10 emission of each aggregate fraction were also measured. Results showed that NT promoted OM accumulations in all aggregate fractions which favored DAS and soil aggregation. The <0.42 mm sized aggregates (27%) predominated in CT and the >19.2 mm (41.7%) in NT, while the proportion of the other aggregate fractions was similar in both tillage systems. As a consequence of the smaller proportion of the <0.42 mm aggregates, the erodible fraction was lower in NT (EF: 17.3%) than in CT (30.8%). PM10 emissions of each aggregate fraction (AE) decreased exponentially with increasing size of the fractions in both tillage systems, mainly as a consequence of the smaller size and higher specific surface. AE was higher in CT than in NT for all aggregate fractions, but the higher differences were found in the <0.42 mm aggregates (18 μg g-1 in CT vs 8 μg g-1 in NT). The PM10 emission of the whole soil was three times higher in CT than in NT, while the emission of the erodible fraction (EFE) was in CT four times higher than in NT. PM10 emissions of the <0.42 mm aggregates represented over 50% of SE and 90% of EFE. We concluded that NT reduced the capacity of soils of the semiarid Pampas to emit PM10 because it produced a better aggregation that reduced the proportion and emission of the <0.42 mm aggregates. These aggregates had, by far, the highest emission potential.
Role of computed tomography angiography in detection and staging of small bowel carcinoid tumors
Bonekamp, David; Raman, Siva P; Horton, Karen M; Fishman, Elliot K
2015-01-01
Small-bowel carcinoid tumors are the most common form (42%) of gastrointestinal carcinoids, which by themselves comprise 70% of neuroendocrine tumors. Although primary small bowel neoplasms are overall rare (3%-6% of all gastrointestinal neoplasms), carcinoids still represent the second most common (20%-30%) primary small-bowel malignancy after small bowel adenocarcinoma. Their imaging evaluation is often challenging. State-of-the-art high-resolution multiphasic computed tomography together with advanced postprocessing methods provides an excellent tool for their depiction. The manifold interactive parameter choices however require knowledge of when to use which technique. Here, we discuss the imaging appearance and evaluation of duodenal, jejunal and ileal carcinoid tumors, including the imaging features of the primary tumor, locoregional mesenteric nodal metastases, and distant metastatic disease. A protocol for optimal lesion detection is presented, including the use of computed tomography enterography, volume acquisition, computed tomography angiography and three-dimensional mapping. Imaging findings are illustrated with a series of challenging cases which illustrate the spectrum of possible disease in the small bowel and mesentery, the range of possible appearances in the bowel itself on multiphase data and extraluminal findings such as the desmoplastic reaction in mesentery and hypervascular liver metastases. Typical imaging pitfalls and pearls are illustrated. PMID:26435774
Modified Goel’s Methods for Basilar Impression: A Case Report with Literature
Asamoto, Shunji; Fukui, Yasuyuki; Nishiyama, Makoto; Ishikawa, Masayuki; Nakamura, Satoshi; Nagashima, Masaki; Muto, Jun; Jimbo, Hiroyuki
2016-01-01
We report the case of a 57-year-old woman who had basilar impression manifesting as severe myelopathy and occipital neuralgia and was treated by distraction and fixation performed using a modification of Goel’s method. Magnetic resonance imaging (MRI) and computed tomography (CT) scans showed severe myelocompression by the dens of the axis from the ventral side and occipitalization of the atlas. After traction using a Halo vest, C1–2 facet distraction and fixation was performed in one stage using a modified Goel’s method. Although Goel et al. used a custom-made spacer to distract the facet joints, we used a threaded titanium cylindrical cage that was inserted into the joint to fix the C1–2 facet joint with posterior fixation from occipital bone to C5. Postoperatively, gradual symptomatic and neurological amelioration were observed. The atlantoaxial joints were bone-fused at 3 years post-operation. Distraction and fixation performed using this modified version of Goel’s method was effective for treating basilar invagination. The threaded titanium cylindrical cage provided adequate C1–2 space and strong initial fixation. PMID:28663991
Van den Bulcke, Marc; Lievens, Antoon; Barbau-Piednoir, Elodie; MbongoloMbella, Guillaume; Roosens, Nancy; Sneyers, Myriam; Casi, Amaya Leunda
2010-03-01
The detection of genetically modified (GM) materials in food and feed products is a complex multi-step analytical process invoking screening, identification, and often quantification of the genetically modified organisms (GMO) present in a sample. "Combinatory qPCR SYBRGreen screening" (CoSYPS) is a matrix-based approach for determining the presence of GM plant materials in products. The CoSYPS decision-support system (DSS) interprets the analytical results of SYBRGREEN qPCR analysis based on four values: the C(t)- and T(m) values and the LOD and LOQ for each method. A theoretical explanation of the different concepts applied in CoSYPS analysis is given (GMO Universe, "Prime number tracing", matrix/combinatory approach) and documented using the RoundUp Ready soy GTS40-3-2 as an example. By applying a limited set of SYBRGREEN qPCR methods and through application of a newly developed "prime number"-based algorithm, the nature of subsets of corresponding GMO in a sample can be determined. Together, these analyses provide guidance for semi-quantitative estimation of GMO presence in a food and feed product.
Liu, Guozhen; Liu, Jingquan; Davis, Thomas P; Gooding, J Justin
2011-04-15
Electrodes modified with passivating organic layers have been shown to, here and previously, to exhibit good Faradaic electrochemistry upon attachment of gold nanoparticles (AuNP). Due to their low background capacitances these constructs have good potential in electrochemical sensing. Herein is reported the application of these electrode constructs for impedance based immunosensing. The immunosensor was constructed by modifying a gold electrode with 4-thiophenol (4-TP) passivating layers by diazonium salt chemistry. Subsequently, the attachment of AuNP and then a biotin derivative as a model epitope to detect anti-biotin IgG were carried out. The interfacial properties of the modified electrodes were evaluated in the presence of Fe(CN)(6)(4-/3-) redox couple as a probe by cyclic voltammetry and electrochemical impedance spectroscopy. The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect anti-biotin IgG. The increase in charge-transfer resistance (R(ct)) was linearly proportional to the concentration of anti-biotin IgG in the range of 5-500 ng mL(-1), with a detection limit of 5 ng mL(-1). Copyright © 2011 Elsevier B.V. All rights reserved.
Chronic relapsing pancreatitis from a scorpion sting in Trinidad.
George Angus, L D; Salzman, S; Fritz, K; Ramirez, J; Yaman, M; Gintautas, J
1995-12-01
Chronic relapsing pancreatitis is a rare cause of abdominal pain in children and exceptionally rarely is related to a scorpion sting. We describe a 13-year-old girl who, following envenoming by a scorpion, developed recurrent attacks of sharp, intermittent pain in the umbilical region associated with fever, nausea, anorexia and vomiting, and changes in her psychological behaviour. Thorough clinical evaluation, including CT scanning, disclosed unabated pancreatitis. A modified Puestow procedure was performed with very good results. Physicians should be aware that in chronic relapsing pancreatitis, particularly in children, a scorpion sting should be considered an aetiological possibility.
Asymptomatic young man with an incidental murmur.
Shojaeifard, Maryam; Pouraliakbar, Hamid Reza; Houshmand, Golnaz
2018-05-31
A 32-year old man was referred to our institution for transthoracic echocardiography (TTE) following detection of an incidental murmur on physical examination before blood donation. He was asymptomatic with no significant medical history. Physical examination revealed dual heart sounds with a grade II/VI systolic murmur heard in the left sternal border. An ECG was in normal sinus rhythm. TTE was performed (figure 1A-C, online supplementary videos 1-4) followed by cardiac CT angiography (CTA) (figure 1D,E).heartjnl;heartjnl-2018-313223v1/F1F1F1Figure 1(A) Transthoracic echocardiography, parasternal left ventricular long axis view. (B) Colour Doppler of modified short axis in the mid-left ventricular level. (C) Doppler flow velocity profile. (D) Cardiac CT angiography (CTA) sagittal reconstruction. (E) Three-dimensional CTA reconstruction of the heart. What is the diagnosis?Pericardial cyst.Ventricular septal defect.Kawasaki.Anomalous left coronary artery from pulmonary artery (ALCAPA). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Topical Review: Polymer gel dosimetry
Baldock, C; De Deene, Y; Doran, S; Ibbott, G; Jirasek, A; Lepage, M; McAuley, K B; Oldham, M; Schreiner, L J
2010-01-01
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. PMID:20150687
Direct composite fillings: an optical coherence tomography and microCT investigation
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Sinescu, Cosmin; Borlea, Mugurel V.; Manescu, Adrian; Duma, Virgil F.; Rominu, Mihai; Podoleanu, Adrian G.
2015-03-01
The treatment of carious lesions requires removal of affected dental tissue thus creating cavities that are to be filled with dedicated materials. There are several methods known which are used to assess the quality of direct dental restorations, but most of them are invasive. Optical tomographic techniques are of particular importance in the medical imaging field, because these techniques can provide non-invasive diagnostic images. Using an en-face version of OCT, we have recently demonstrated real time thorough evaluation of quality of dental fillings. The major aim of this study was to analyses the optical performance of adhesives modified with zirconia particles in different concentrations in order to improve the contrast of OCT imaging of the interface between the tooth structure, adhesive and composite resin. The OCT investigations were validated by micro CT using synchrotron radiation. The OCT Swept Source is a valuable investigation tool for the clinical evaluation of class II direct composite restorations. The unmodified adhesive layer shows poor contrast on regular OCT investigations. Adding zirconia particles to the adhesive layer provides a better scattering which allows a better characterization and quantification of direct restorations.
A double mutation in AGXT gene in families with primary hyperoxaluria type 1.
Kanoun, Houda; Jarraya, Faiçal; Hadj Salem, Ikhlass; Mahfoudh, Hichem; Chaabouni, Yosr; Makni, Fatma; Hachicha, Jamil; Fakhfakh, Faiza
2013-12-01
Primary hyperoxaluria type 1 (PH1) is a severe autosomal recessive inherited disorder of glyoxylate metabolism caused by mutations in the AGXT gene on chromosome 2q37.3 that encodes the hepatic peroxisomal enzyme alanine:glyoxylate aminotransferase. These mutations are found throughout the entire gene and cause a wide spectrum of clinical severity. Rare in Europe, PH1 is responsible for 13% of the end stage renal failure in the Tunisian child. In the present work, we identified the double mutation c.32C>T (Pro11Leu) and c.731T>C (p.Ile244Thr) in AGXT gene in five unrelated Tunisian families with PH1 disease. Our results provide evidence regarding the potential involvement of c.32C>T, originally described as common polymorphism, on the resulting phenotype. We also reported an extreme intrafamilial heterogeneity in clinical presentation of PH1. Despite the same genetic background, the outcome of the affected members differs widely. The significant phenotypic heterogeneity observed within a same family, with a same genotype, suggests the existence of relevant modifier factors. © 2013.
NASA Astrophysics Data System (ADS)
Chen, Chen; Klämpfl, Florian; Stelzle, Florian; Schmidt, Michael
2014-11-01
An imging resolution of micron-scale has not yet been discovered by diffuse optical imaging (DOI), while a superficial response was eliminated. In this work, we report on a new approach of DOI with a local off-set alignment to subvert the common boundary conditions of the modified Beer-Lambert Law (MBLL). It can resolve a superficial target in micron scale under a turbid media. To validate both major breakthroughs, this system was used to recover a subsurface microvascular mimicking structure under an skin equivalent phantom. This microvascular was included with oxy-hemoglobin solution in variant concentrations to distiguish the absolute values of CtRHb and CtHbO2 . Experimental results confirmed the feasibility of recovering the target vascular of 50 µm in diameter, and graded the values of the concentrations of oxy-hemoglobin from 10 g/L to 50 g/L absolutely. Ultimately, this approach could evolve into a non-invasive imaging system to map the microvascular pattern and the associated oximetry under a human skin in-vivo.
Do Chondral Lesions of the Knee Correlate with Bone Tracer Uptake by Using SPECT/CT?
Dordevic, Milos; Hirschmann, Michael T; Rechsteiner, Jan; Falkowski, Anna; Testa, Enrique; Hirschmann, Anna
2016-01-01
To evaluate the correlation of bone tracer uptake as determined with single photon emission computed tomography (SPECT)/computed tomography (CT) and the size and severity of chondral lesions detected with magnetic resonance (MR) imaging of the knee. MR imaging and SPECT/CT images of 63 knee joints in 63 patients (mean age ± standard deviation, 49.2 years ± 12.7) with chondral or osteochondral lesions were prospectively collected and retrospectively analyzed after approval by the ethics committee. Chondral lesions were graded on MR images by using a modified Noyes grading scale (grade 0, intact; grade 1, fibrillations; grade 2, <50% defect; grade 3, >50% defect; and grade 4, grade three plus subchondral changes) and measured in two dimensions. Technetium 99m hydroxymethane diphosphonate SPECT/CT bone tracer uptake was volumetrically quantified by using validated software. Maximum values of each subchondral area (patellofemoral or medial and lateral femorotibial) were quantified, and a ratio was calculated in relation to a reference region in the femoral shaft, which represented the bone tracer uptake background activity. Grades and sizes of chondral lesions and bone tracer uptake were correlated by using an independent t test and analysis of variance (P < .05). Bone tracer uptake was low (mean relative uptake, 1.64 ± 0.95) in knees without any present chondral lesion. In knees with grade 3 and 4 chondral lesions, the relative ratio was significantly higher (3.62 ± 2.18, P = .002) than in knees with grade 1 and 2 lesions (2.95 ± 2.07). The larger the diameter of the chondral lesion, the higher the bone tracer uptake. Higher grades of chondral lesions (grades 3 and 4) larger than 4 cm(2) (4.96 ± 2.43) showed a significantly higher bone tracer uptake than smaller lesions (<1 cm(2), 2.72 ± 1.43 [P = .011]; and 1-4 cm(2), 3.28 ± 2.15 [P = .004]). SPECT/CT findings significantly correlate with the degree and size of chondral lesions on MR images. Grade 3 and 4 chondral lesions of the knee, as well as larger lesions, correlate with a high bone tracer uptake. © RSNA, 2015.
Boers, Anna M M; Jansen, Ivo G H; Beenen, Ludo F M; Devlin, Thomas G; San Roman, Luis; Heo, Ji Hoe; Ribó, Marc; Brown, Scott; Almekhlafi, Mohammed A; Liebeskind, David S; Teitelbaum, Jeanne; Lingsma, Hester F; van Zwam, Wim H; Cuadras, Patricia; du Mesnil de Rochemont, Richard; Beaumont, Marine; Brown, Martin M; Yoo, Albert J; van Oostenbrugge, Robert J; Menon, Bijoy K; Donnan, Geoffrey A; Mas, Jean Louis; Roos, Yvo B W E M; Oppenheim, Catherine; van der Lugt, Aad; Dowling, Richard J; Hill, Michael D; Davalos, Antoni; Moulin, Thierry; Agrinier, Nelly; Demchuk, Andrew M; Lopes, Demetrius K; Aja Rodríguez, Lucia; Dippel, Diederik W J; Campbell, Bruce C V; Mitchell, Peter J; Al-Ajlan, Fahad S; Jovin, Tudor G; Madigan, Jeremy; Albers, Gregory W; Soize, Sebastien; Guillemin, Francis; Reddy, Vivek K; Bracard, Serge; Blasco, Jordi; Muir, Keith W; Nogueira, Raul G; White, Phil M; Goyal, Mayank; Davis, Stephen M; Marquering, Henk A; Majoie, Charles B L M
2018-04-07
Follow-up infarct volume (FIV) has been recommended as an early indicator of treatment efficacy in patients with acute ischemic stroke. Questions remain about the optimal imaging approach for FIV measurement. To examine the association of FIV with 90-day modified Rankin Scale (mRS) score and investigate its dependency on acquisition time and modality. Data of seven trials were pooled. FIV was assessed on follow-up (12 hours to 2 weeks) CT or MRI. Infarct location was defined as laterality and involvement of the Alberta Stroke Program Early CT Score regions. Relative quality and strength of multivariable regression models of the association between FIV and functional outcome were assessed. Dependency of imaging modality and acquisition time (≤48 hours vs >48 hours) was evaluated. Of 1665 included patients, 83% were imaged with CT. Median FIV was 41 mL (IQR 14-120). A large FIV was associated with worse functional outcome (OR=0.88(95% CI 0.87 to 0.89) per 10 mL) in adjusted analysis. A model including FIV, location, and hemorrhage type best predicted mRS score. FIV of ≥133 mL was highly specific for unfavorable outcome. FIV was equally strongly associated with mRS score for assessment on CT and MRI, even though large differences in volume were present (48 mL (IQR 15-131) vs 22 mL (IQR 8-71), respectively). Associations of both early and late FIV assessments with outcome were similar in strength (ρ=0.60(95% CI 0.56 to 0.64) and ρ=0.55(95% CI 0.50 to 0.60), respectively). In patients with an acute ischemic stroke due to a proximal intracranial occlusion of the anterior circulation, FIV is a strong independent predictor of functional outcome and can be assessed before 48 hours, oneither CT or MRI. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Zhang, J; Qin, A
2016-06-15
Purpose: To evaluate the potential benefits of robust optimization in intensity modulated proton therapy(IMPT) treatment planning to account for inter-fractional variation for Head Neck Cancer(HNC). Methods: One patient with bilateral HNC previous treated at our institution was used in this study. Ten daily CBCTs were selected. The CT numbers of the CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration. The planning target volumes(PTVs) were defined by a 3mm expansion from clinical target volumes(CTVs). The prescription was 70Gy, 54Gy to CTV1, CTV2, and PTV1, PTV2 for robust optimized(RO) and conventionally optimized(CO) plans respectively. Bothmore » techniques were generated by RayStation with the same beam angles: two anterior oblique and two posterior oblique angles. The similar dose constraints were used to achieve 99% of CTV1 received 100% prescription dose while kept the hotspots less than 110% of the prescription. In order to evaluate the dosimetric result through the course of treatment, the contours were deformed from simulation CT to daily CBCTs, modified, and approved by a radiation oncologist. The initial plan on the simulation CT was re-replayed on the daily CBCTs followed the bony alignment. The target coverage was evaluated using the daily doses and the cumulative dose. Results: Eight of 10 daily deliveries with using RO plan achieved at least 95% prescription dose to CTV1 and CTV2, while still kept maximum hotspot less than 112% of prescription compared with only one of 10 for the CO plan to achieve the same standards. For the cumulative doses, the target coverage for both RO and CO plans was quite similar, which was due to the compensation of cold and hot spots. Conclusion: Robust optimization can be effectively applied to compensate for target dose deficit caused by inter-fractional target geometric variation in IMPT treatment planning.« less
WE-D-BRA-05: Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ger, R; Craft, DF; Burgett, EA
Purpose: To test the feasibility of using 3D-printed patient-specific phantoms for intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We created a patient-specific whole-head phantom using a 3D printer. The printer data file was created from high-resolution DICOM computed tomography (CT) images of 3-year old child treated at our institution for medulloblastoma. A custom-modified extruder system was used to create tissue-equivalent materials. For the printing process, the Hounsfield Units from the CT images were converted to proportional volumetric densities. A 5-field IMRT plan was created from the patient CT and delivered to the 3D- phantom. Dose was measured by anmore » ion chamber placed through the eye. The ion chamber was placed at the posterior edge of the planning target volume in a high dose gradient region. CT scans of the patient and 3D-phantom were fused by using commercial treatment planning software (TPS). The patient’s plan was calculated on the phantom CT images. The ion chamber’s active volume was delineated in the TPS; dose per field and total dose were obtained. Measured and calculated doses were compared. Results: The 3D-phantom dimensions and tissue densities were in good agreement with the patient. However, because of a printing error, there was a large discrepancy in the density in the frontal cortex. The calculated and measured treatment plan doses were 1.74 Gy and 1.72 Gy, respectively. For individual fields, the absolute dose difference between measured and calculated values was on average 3.50%. Conclusion: This study demonstrated the feasibility of using 3D-printed patient-specific phantoms for IMRT QA. Such phantoms would be particularly advantageous for complex IMRT treatment plans featuring high dose gradients and/or for anatomical sites with high variation in tissue densities. Our preliminary findings are promising. We anticipate that, once the printing process is further refined, the agreement between measured and calculated doses will improve.« less
Ye, Q; Heck, G L; DeSimone, J A
1993-07-01
1. Voltage-clamp and current-clamp data were obtained from a circumscribed region of the anterior rat lingual epithelium while simultaneously monitoring the afferent, stimulus-evoked, neural response from the same receptive field. 2. Chorda tympani (CT) responses at constant Na(+)-salt concentration were enhanced by submucosa negative voltage clamp and suppressed by positive voltage clamp. The complete CT response profile, including the time course of adaptation, was not uniquely determined by NaCl concentration alone. The response could be reproduced at different NaCl concentrations by applying a compensating voltage. 3. The form of the concentration and voltage dependence of the CT response indicates that the complete stimulus energy is the Na+ electrochemical potential difference across receptor cell apical membranes, and not Na+ concentration alone. This is the underlying principal behind the equivalence of chemical and electric taste for Na+ salts. 4. CT responses to sodium gluconate (25 and 200 mM) and 25 mM NaCl produced amiloride-insensitive components (AIC) of low magnitude. NaCl at 200 mM produced a significantly larger AIC. The AIC was voltage-clamp independent. The relative magnitude of the AIC was positively correlated with the transepithelial conductance of each salt. This suggests that the large AIC for 200 mM NaCl results from its relatively high permeability through the paracellular pathway. 5. Analysis of the CT response under voltage clamp revealed two anion effects on Na(+)-salt taste, both of which act through the paracellular shunt. 1) Anions modify the transepithelial potential (TP) across tight junctions and thereby modulate the cell receptor potential. This anion effect can be eliminated by voltage clamping the TP. 2) Sufficiently mobile anions facilitate electroneutral diffusion of Na+ salts through tight junctions. This effect is observed especially when Cl- is the anion and when the stimulus concentration favors NaCl influx, allowing Na+ to stimulate receptor cells from the submucosal side. Because the submucosal intercellular spaces are nearly isopotential regions, this effect is insensitive to voltage clamp of the TP. The large AIC associated with this anion effect is due to the low permeability of amiloride.
ExaCT: automatic extraction of clinical trial characteristics from journal publications
2010-01-01
Background Clinical trials are one of the most important sources of evidence for guiding evidence-based practice and the design of new trials. However, most of this information is available only in free text - e.g., in journal publications - which is labour intensive to process for systematic reviews, meta-analyses, and other evidence synthesis studies. This paper presents an automatic information extraction system, called ExaCT, that assists users with locating and extracting key trial characteristics (e.g., eligibility criteria, sample size, drug dosage, primary outcomes) from full-text journal articles reporting on randomized controlled trials (RCTs). Methods ExaCT consists of two parts: an information extraction (IE) engine that searches the article for text fragments that best describe the trial characteristics, and a web browser-based user interface that allows human reviewers to assess and modify the suggested selections. The IE engine uses a statistical text classifier to locate those sentences that have the highest probability of describing a trial characteristic. Then, the IE engine's second stage applies simple rules to these sentences to extract text fragments containing the target answer. The same approach is used for all 21 trial characteristics selected for this study. Results We evaluated ExaCT using 50 previously unseen articles describing RCTs. The text classifier (first stage) was able to recover 88% of relevant sentences among its top five candidates (top5 recall) with the topmost candidate being relevant in 80% of cases (top1 precision). Precision and recall of the extraction rules (second stage) were 93% and 91%, respectively. Together, the two stages of the extraction engine were able to provide (partially) correct solutions in 992 out of 1050 test tasks (94%), with a majority of these (696) representing fully correct and complete answers. Conclusions Our experiments confirmed the applicability and efficacy of ExaCT. Furthermore, they demonstrated that combining a statistical method with 'weak' extraction rules can identify a variety of study characteristics. The system is flexible and can be extended to handle other characteristics and document types (e.g., study protocols). PMID:20920176
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiner, Caecilia S., E-mail: caecilia.reiner@usz.ch; Gordic, Sonja; Puippe, Gilbert
2016-03-15
PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogrammore » analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min{sup −1} 100 mL{sup −1}); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min{sup −1} 100 mL{sup −1}; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min{sup −1} 100 mL{sup −1}, therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Derek; Mutanga, Theodore
Purpose: An end-to-end testing methodology was designed to evaluate the overall SRS treatment fidelity, incorporating all steps in the linac-based frameless radiosurgery treatment delivery process. The study details our commissioning experience of the Steev (CIRS, Norfolk, VA) stereotactic anthropomorphic head phantom including modification, test design, and baseline measurements. Methods: Repeated MR and CT scans were performed with interchanging inserts. MR-CT fusion accuracy was evaluated and the insert spatial coincidence was verified on CT. Five non-coplanar arcs delivered a prescription dose to a 15 mm spherical CTV with 2 mm PTV margin. Following setup, CBCT-based shifts were applied as per protocol.more » Sequential measurements were performed by interchanging inserts without disturbing the setup. Spatial and dosimetric accuracy was assessed by a combination of CBCT hidden target, radiochromic film, and ion chamber measurements. To facilitate film registration, the film insert was modified in-house by etching marks. Results: MR fusion error and insert spatial coincidences were within 0.3 mm. Both CBCT and film measurements showed spatial displacements of 1.0 mm in similar directions. Both coronal and sagittal films reported 2.3 % higher target dose relative to the treatment plan. The corrected ion chamber measurement was similarly greater by 1.0 %. The 3 %/2 mm gamma pass rate was 99% for both films Conclusions: A comprehensive end-to-end testing methodology was implemented for our SRS QA program. The Steev phantom enabled realistic evaluation of the entire treatment process. Overall spatial and dosimetric accuracy of the delivery were 1 mm and 3 % respectively.« less
Modeling of carbonate reservoir variable secondary pore space based on CT images
NASA Astrophysics Data System (ADS)
Nie, X.; Nie, S.; Zhang, J.; Zhang, C.; Zhang, Z.
2017-12-01
Digital core technology has brought convenience to us, and X-ray CT scanning is one of the most common way to obtain 3D digital cores. However, it can only provide the original information of the only samples being scanned, and we can't modify the porosity of the scanned cores. For numerical rock physical simulations, a series of cores with variable porosities are needed to determine the relationship between the physical properties and porosity. In carbonate rocks, the secondary pore space including dissolution pores, caves and natural fractures is the key reservoir space, which makes the study of carbonate secondary porosity very important. To achieve the variation of porosities in one rock sample, based on CT scanned digital cores, according to the physical and chemical properties of carbonate rocks, several mathematical methods are chosen to simulate the variation of secondary pore space. We use the erosion and dilation operations of mathematical morphology method to simulate the pore space changes of dissolution pores and caves. We also use the Fractional Brownian Motion model to generate natural fractures with different widths and angles in digital cores to simulate fractured carbonate rocks. The morphological opening-and-closing operations in mathematical morphology method are used to simulate distribution of fluid in the pore space. The established 3D digital core models with different secondary porosities and water saturation status can be used in the study of the physical property numerical simulations of carbonate reservoir rocks.
Dewi, Vitri; Kwok, Alister; Lee, Stella; Lee, Ming Min; Tan, Yee Mun; Nicholas, Hannah R; Isono, Kyo-ichi; Wienert, Beeke; Mak, Ka Sin; Knights, Alexander J; Quinlan, Kate G R; Cordwell, Stuart J; Funnell, Alister P W; Pearson, Richard C M; Crossley, Merlin
2015-03-27
Krüppel-like factor 3 (KLF3/BKLF), a member of the Krüppel-like factor (KLF) family of transcription factors, is a widely expressed transcriptional repressor with diverse biological roles. Although there is considerable understanding of the molecular mechanisms that allow KLF3 to silence the activity of its target genes, less is known about the signal transduction pathways and post-translational modifications that modulate KLF3 activity in response to physiological stimuli. We observed that KLF3 is modified in a range of different tissues and found that the serine/threonine kinase homeodomain-interacting protein kinase 2 (HIPK2) can both bind and phosphorylate KLF3. Mass spectrometry identified serine 249 as the primary phosphorylation site. Mutation of this site reduces the ability of KLF3 to bind DNA and repress transcription. Furthermore, we also determined that HIPK2 can phosphorylate the KLF3 co-repressor C-terminal binding protein 2 (CtBP2) at serine 428. Finally, we found that phosphorylation of KLF3 and CtBP2 by HIPK2 strengthens the interaction between these two factors and increases transcriptional repression by KLF3. Taken together, our results indicate that HIPK2 potentiates the activity of KLF3. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Gupta, Devanand; Batra, Renu; Mahajan, Shveta; Bhaskar, Dara John; Jain, Ankita; Shiju, Mohammed; Yadav, Ankit; Chaturvedi, Mudita; Gill, Shruti; Verma, Renuka; Dalai, Deepak Ranjan; Gupta, Rajendra Kumar
2014-10-01
Musculoskeletal problems have become a significant issue in the profession of dentistry. There are currently no recommended effective disease-preventing and modifying remedies. High prevalence rates for musculoskeletal disorders (MSDs) among dentists have been reported in the literature. Complementary and alternative medicine can be helpful in managing and preventing the MSDs. The purpose of this study was to determine if dentists in the western part of India are using complementary and alternative medicine therapies for MSDs, and also to find if those who use complementary and alternative medicine therapies have greater job/career satisfaction compared to conventional therapy (CT) users. Dentists of western India registered under the Dental Council of India (N = 2166) were recruited for the study. Data were analyzed using univariate and bivariate analyses and logistic regression. A response rate of 73% (n = 1581) was obtained, of which 79% (n = 1249) was suffering from MSDs. The use of complementary and alternative medicine or CT was reported by 90% (n = 1124) of dentists with MSDs. Dentists using complementary and alternative medicine reported greater health (P < 0.001) and carrier satisfaction (P < 0.001) and were able to work as many hours they wanted (P < 0.001) compared to CT users. Complementary and alternative medicine therapies may improve the quality of life and enhance job satisfaction for a dentist who suffers from MSDs.
Zhao, Dan; Hu, Qiaoqiao; Qi, Liping; Wang, Juan; Wu, Hao; Zhu, Guangying; Yu, Huiming
2017-02-01
We investigate the impact of magnetic resonance (MR) on the staging and radiotherapy planning for patients with nonsmall cell lung cancer (NSCLC).A total of 24 patients with NSCLC underwent MRI, which was fused with radiotherapy planning CT using rigid registration. Gross tumor volume (GTV) was delineated not only according to CT image alone (GTVCT), but also based on both CT and MR image (GTVCT/MR). For each patient, 2 conformal treatment plans were made according to GTVCT and GTVCT/MR, respectively. Dose-volume histograms (DVH) for lesion and normal organs were generated using both GTVCT and GTVCT/MR treatment plans. All patients were irradiated according to GTVCT/MR plan.Median volume of the GTVCT/MR and GTVCT were 105.42 cm and 124.45 cm, respectively, and the mean value of GTVCT/MR was significantly smaller than that of GTVCT (145.71 ± 145.04 vs 174.30 ± 150.34, P < 0.01). Clinical stage was modified in 9 patients (37.5%). The objective response rate (ORR) was 83.3% and the l-year overall survival (OS) was 87.5%.MR is a useful tool in radiotherapy treatment planning for NSCLC, which improves the definition of tumor volume, reduces organs at risk dose and does not increase the local recurrence rate.
Gupta, Devanand; Batra, Renu; Mahajan, Shveta; Bhaskar, Dara John; Jain, Ankita; Shiju, Mohammed; Yadav, Ankit; Chaturvedi, Mudita; Gill, Shruti; Verma, Renuka; Dalai, Deepak Ranjan; Gupta, Rajendra Kumar
2014-01-01
Musculoskeletal problems have become a significant issue in the profession of dentistry. There are currently no recommended effective disease-preventing and modifying remedies. High prevalence rates for musculoskeletal disorders (MSDs) among dentists have been reported in the literature. Complementary and alternative medicine can be helpful in managing and preventing the MSDs. The purpose of this study was to determine if dentists in the western part of India are using complementary and alternative medicine therapies for MSDs, and also to find if those who use complementary and alternative medicine therapies have greater job/career satisfaction compared to conventional therapy (CT) users. Dentists of western India registered under the Dental Council of India (N = 2166) were recruited for the study. Data were analyzed using univariate and bivariate analyses and logistic regression. A response rate of 73% (n = 1581) was obtained, of which 79% (n = 1249) was suffering from MSDs. The use of complementary and alternative medicine or CT was reported by 90% (n = 1124) of dentists with MSDs. Dentists using complementary and alternative medicine reported greater health (P < 0.001) and carrier satisfaction (P < 0.001) and were able to work as many hours they wanted (P < 0.001) compared to CT users. Complementary and alternative medicine therapies may improve the quality of life and enhance job satisfaction for a dentist who suffers from MSDs. PMID:25379469
Active Galactic Nuclei, Host Star Formation, and the Far Infrared
NASA Astrophysics Data System (ADS)
Draper, Aden R.; Ballantyne, D. R.
2011-05-01
Telescopes like Herschel and the Atacama Large Millimeter/submillimeter Array (ALMA) are creating new opportunities to study sources in the far infrared (FIR), a wavelength region dominated by cold dust emission. Probing cold dust in active galaxies allows for study of the star formation history of active galactic nuclei (AGN) hosts. The FIR is also an important spectral region for observing AGN which are heavily enshrouded by dust, such as Compton thick (CT) AGN. By using information from deep X-ray surveys and cosmic X-ray background synthesis models, we compute Cloudy photoionization simulations which are used to predict the spectral energy distribution (SED) of AGN in the FIR. Expected differential number counts of AGN and their host galaxies are calculated in the Herschel bands. The expected contribution of AGN and their hosts to the cosmic infrared background (CIRB) is also computed. Multiple star formation scenarios are investigated using a modified blackbody star formation SED. It is found that FIR observations at 350 and 500 um are an excellent tool in determining the star formation history of AGN hosts. Additionally, the AGN contribution to the CIRB can be used to determine whether star formation in AGN hosts evolves differently than in normal galaxies. AGN and host differential number counts are dominated by CT AGN in the Herschel-SPIRE bands. Therefore, X-ray stacking of bright SPIRE sources is likely to disclose a large fraction of the CT AGN population.
NASA Astrophysics Data System (ADS)
Xu, S.; Uneri, A.; Khanna, A. Jay; Siewerdsen, J. H.; Stayman, J. W.
2017-04-01
Metal artifacts can cause substantial image quality issues in computed tomography. This is particularly true in interventional imaging where surgical tools or metal implants are in the field-of-view. Moreover, the region-of-interest is often near such devices which is exactly where image quality degradations are largest. Previous work on known-component reconstruction (KCR) has shown the incorporation of a physical model (e.g. shape, material composition, etc) of the metal component into the reconstruction algorithm can significantly reduce artifacts even near the edge of a metal component. However, for such approaches to be effective, they must have an accurate model of the component that include energy-dependent properties of both the metal device and the CT scanner, placing a burden on system characterization and component material knowledge. In this work, we propose a modified KCR approach that adopts a mixed forward model with a polyenergetic model for the component and a monoenergetic model for the background anatomy. This new approach called Poly-KCR jointly estimates a spectral transfer function associated with known components in addition to the background attenuation values. Thus, this approach eliminates both the need to know component material composition a prior as well as the requirement for an energy-dependent characterization of the CT scanner. We demonstrate the efficacy of this novel approach and illustrate its improved performance over traditional and model-based iterative reconstruction methods in both simulation studies and in physical data including an implanted cadaver sample.
Shi, Jiajia; Sun, Jie; Zhang, Wen; Liang, Hui; Shi, Qin; Li, Xiaoran; Chen, Yanyan; Zhuang, Yan; Dai, Jianwu
2016-10-07
The reconstruction of bone usually depends on substitute transplantation, which has drawbacks including the limited bone substitutes available, comorbidity, immune rejection, and limited endogenous bone regeneration. Here, we constructed a functionalized bone substitute by combining application of the demineralized bone matrix (DBM) and collagen-binding stromal-cell-derived factor-1α (CBD-SDF-1α). DBM was a poriferous and biodegradable bone substitute, derived from bovine bone and consisting mainly of collagen. CBD-SDF-1α could bind to collagen and be controllably released from the DBM to mobilize stem cells. In a rat femur defect model, CBD-SDF-1α-modified DBM scaffolds could efficiently mobilize CD34 + and c-kit + endogenous stem cells homing to the injured site at 3 days after implantation. According to the data from micro-CT, CBD-SDF-1α-modified DBM scaffolds could help the bone defects rejoin with mineralization accumulated and bone volume expanded. Interestingly, osteoprotegerin (OPG) and osteopontin (OPN) were highly expressed in CBD-SDF-1α group at an early time after implantation, while osteocalcin (OCN) was more expanded. H&E and Masson's trichrome staining showed that the CBD-SDF-1α-modified DBM scaffold group had more osteoblasts and that the bone defect rejoined earlier. The ultimate strength of the regenerated bone was investigated by three-point bending, showing that the CBD-SDF-1α group had superior strength. In conclusion, CBD-SDF-1α-modified DBM scaffolds could promote bone regeneration by recruiting endogenous stem cells.
Devaraj, Bikash; Liu, Wendy; Tatum, James; Cologne, Kyle; Kaiser, Andreas M
2016-03-01
The best management for diverticulitis with abscess formation remains unknown. The purpose of this study was to determine the natural course and outcomes of patients with medically treated diverticular abscess. We conducted a retrospective review of all patients at our institution with diverticular abscess confirmed by CT from 2004 to 2014. This study was conducted in a tertiary referral hospital. A total of 1194 patients were treated for acute diverticulitis in 10 years; 210 patients with CT-documented diverticular abscess were analyzed (140 men (66.7%) and 70 women (33.3%); median age 45 years; range, 23-84 years). Overall recurrence and disease complication rates, as well as the need for subsequent operation after initial successful nonsurgical management, were measured, along with analysis of the whole cohort and the subgroup of patients with percutaneous drainage for diverticular abscess. During the initial presentation, 25 patients failed nonoperative management and required an urgent operation. A total of 185 patients were initially successfully managed without surgery and were discharged from the hospital. Of these, recurrent diverticulitis developed in 112 (60.5%) after an average time interval of 5.3 months (range, 0.8-20.0 months); 47 patients (42%) experienced more than 1 episode. The modified Hinchey stage at time of recurrence (compared with index stay) increased in 51 patients (45.6%). Seventy one (63%) of 112 recurrences showed local disease complications (recurrent abscess, fistula, stricture, or peritonitis). Fistula formation (colovesicular/colovaginal/colocutaneous) and recurrent abscess were the 2 most frequent complications. Twenty nine (26%) of 112 recurrences required an urgent operation; overall, 66 (59%) of 112 patients eventually underwent surgery at our institution. The original abscess size in patients who later developed recurrences was significantly larger than in patients who did not develop recurrence (5.3 vs 3.2 cm; p < 0.001). Paradoxically, larger abscesses also had a higher chance of successful CT-guided drainage (average size, 6.5 cm; range, 1.1-14 cm), yet CT-guided drainage did not change the overall outcome. Of 65 (31.0%) of 210 patients with CT-guided drainage, 45 (73.8%) of 61 after initial success experienced a recurrence. Furthermore, local disease complications at the time of recurrence were noted in 32 of 61 patients (52.5% of all CT-guided drainage, 71.1% of post-CT-guided drainage recurrences), and 13 (29.2%) of 45 patients with recurrence after successful CT-guided drainage subsequently required an urgent operation. The study was limited by its retrospective noncomparative design. Diverticular abscesses represent complicated diverticulitis and are associated with a high risk of recurrences and disease complications. Recurrences (contrary to other series) were often more severe than the index presentation. The successful CT-guided drainage of a diverticular abscess does not appear to lower the risks of future recurrence or complication rates and frequently is only a bridge to surgery. After initial successful nonoperative management, patients with diverticular abscess should be offered interval elective colectomy (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A216).
Yadav, Kabir; Sarioglu, Efsun; Choi, Hyeong Ah; Cartwright, Walter B; Hinds, Pamela S; Chamberlain, James M
2016-02-01
The authors have previously demonstrated highly reliable automated classification of free-text computed tomography (CT) imaging reports using a hybrid system that pairs linguistic (natural language processing) and statistical (machine learning) techniques. Previously performed for identifying the outcome of orbital fracture in unprocessed radiology reports from a clinical data repository, the performance has not been replicated for more complex outcomes. To validate automated outcome classification performance of a hybrid natural language processing (NLP) and machine learning system for brain CT imaging reports. The hypothesis was that our system has performance characteristics for identifying pediatric traumatic brain injury (TBI). This was a secondary analysis of a subset of 2,121 CT reports from the Pediatric Emergency Care Applied Research Network (PECARN) TBI study. For that project, radiologists dictated CT reports as free text, which were then deidentified and scanned as PDF documents. Trained data abstractors manually coded each report for TBI outcome. Text was extracted from the PDF files using optical character recognition. The data set was randomly split evenly for training and testing. Training patient reports were used as input to the Medical Language Extraction and Encoding (MedLEE) NLP tool to create structured output containing standardized medical terms and modifiers for negation, certainty, and temporal status. A random subset stratified by site was analyzed using descriptive quantitative content analysis to confirm identification of TBI findings based on the National Institute of Neurological Disorders and Stroke (NINDS) Common Data Elements project. Findings were coded for presence or absence, weighted by frequency of mentions, and past/future/indication modifiers were filtered. After combining with the manual reference standard, a decision tree classifier was created using data mining tools WEKA 3.7.5 and Salford Predictive Miner 7.0. Performance of the decision tree classifier was evaluated on the test patient reports. The prevalence of TBI in the sampled population was 159 of 2,217 (7.2%). The automated classification for pediatric TBI is comparable to our prior results, with the notable exception of lower positive predictive value. Manual review of misclassified reports, 95.5% of which were false-positives, revealed that a sizable number of false-positive errors were due to differing outcome definitions between NINDS TBI findings and PECARN clinical important TBI findings and report ambiguity not meeting definition criteria. A hybrid NLP and machine learning automated classification system continues to show promise in coding free-text electronic clinical data. For complex outcomes, it can reliably identify negative reports, but manual review of positive reports may be required. As such, it can still streamline data collection for clinical research and performance improvement. © 2016 by the Society for Academic Emergency Medicine.
Yadav, Kabir; Sarioglu, Efsun; Choi, Hyeong-Ah; Cartwright, Walter B.; Hinds, Pamela S.; Chamberlain, James M.
2016-01-01
Background The authors have previously demonstrated highly reliable automated classification of free text computed tomography (CT) imaging reports using a hybrid system that pairs linguistic (natural language processing) and statistical (machine learning) techniques. Previously performed for identifying the outcome of orbital fracture in unprocessed radiology reports from a clinical data repository, the performance has not been replicated for more complex outcomes. Objectives To validate automated outcome classification performance of a hybrid natural language processing (NLP) and machine learning system for brain CT imaging reports. The hypothesis was that our system has performance characteristics for identifying pediatric traumatic brain injury (TBI). Methods This was a secondary analysis of a subset of 2,121 CT reports from the Pediatric Emergency Care Applied Research Network (PECARN) TBI study. For that project, radiologists dictated CT reports as free text, which were then de-identified and scanned as PDF documents. Trained data abstractors manually coded each report for TBI outcome. Text was extracted from the PDF files using optical character recognition. The dataset was randomly split evenly for training and testing. Training patient reports were used as input to the Medical Language Extraction and Encoding (MedLEE) NLP tool to create structured output containing standardized medical terms and modifiers for negation, certainty, and temporal status. A random subset stratified by site was analyzed using descriptive quantitative content analysis to confirm identification of TBI findings based upon the National Institute of Neurological Disorders and Stroke Common Data Elements project. Findings were coded for presence or absence, weighted by frequency of mentions, and past/future/indication modifiers were filtered. After combining with the manual reference standard, a decision tree classifier was created using data mining tools WEKA 3.7.5 and Salford Predictive Miner 7.0. Performance of the decision tree classifier was evaluated on the test patient reports. Results The prevalence of TBI in the sampled population was 159 out of 2,217 (7.2%). The automated classification for pediatric TBI is comparable to our prior results, with the notable exception of lower positive predictive value (PPV). Manual review of misclassified reports, 95.5% of which were false positives, revealed that a sizable number of false-positive errors were due to differing outcome definitions between NINDS TBI findings and PECARN clinical important TBI findings, and report ambiguity not meeting definition criteria. Conclusions A hybrid NLP and machine learning automated classification system continues to show promise in coding free-text electronic clinical data. For complex outcomes, it can reliably identify negative reports, but manual review of positive reports may be required. As such, it can still streamline data collection for clinical research and performance improvement. PMID:26766600
Leukoaraiosis predicts poor 90-day outcome after acute large cerebral artery occlusion.
Henninger, Nils; Lin, Eugene; Baker, Stephen P; Wakhloo, Ajay K; Takhtani, Deepak; Moonis, Majaz
2012-01-01
To date limited information regarding outcome-modifying factors in patients with acute intracranial large artery occlusion (ILAO) in the anterior circulation is available. Leukoaraiosis (LA) is a common finding among patients with ischemic stroke and has been associated with poor post-stroke outcomes but its association with ILAO remains poorly characterized. This study sought to clarify the contribution of baseline LA and other common risk factors to 90-day outcome (modified Rankin Scale, mRS) after stroke due to acute anterior circulation ILAO. We retrospectively analyzed 1,153 consecutive patients with imaging-confirmed ischemic stroke during a 4-year period (2007-2010) at a single academic institution. The final study cohort included 87 patients with acute ILAO subjected to multimodal CT imaging within 24 h of symptom onset. LA severity was assessed using the van Swieten scale on non-contrast CT. Leptomeningeal collaterals were graded using CT angiogram source images. Hemorrhagic transformation (HT) was determined on follow-up CT. Multivariate logistic regression controlling for HT, treatment modality, demographic, as well as baseline clinical and imaging characteristics was used to identify independent predictors of a poor outcome (90-day mRS >2). The median National Institutes of Health Stroke Scale (NIHSS) at baseline was 15 (interquartile range 9-21). Twenty-four percent of the studied patients had severe LA. They were more likely to have hypertension (p = 0.028), coronary artery disease (p = 0.015), poor collaterals (p < 0.001), higher baseline NIHSS (p = 0.003), higher mRS at 90 days (p < 0.001), and were older (p = 0.002). Patients with severe LA had a uniformly poor outcome (p < 0.001) irrespective of treatment modality. Poor outcome was independently associated with higher baseline NIHSS (p < 0.001), worse LA (graded and dichotomized, p < 0.001), reduced leptomeningeal collaterals (graded and dichotomized, p < 0.001), presence of HT (p < 0.001), presence of parenchymal hemorrhages (p = 0.01), baseline mRS (p = 0.002), and older age (p = 0.043). The association between severe LA (p = 0.0056; OR 13.86; 95% CI 1.94-∞) and baseline NIHSS (p = 0.0001; OR 5.11; 95% CI 2.07-14.49 for each 10-point increase) with poor outcome maintained after adjustment for confounders in the final regression model. In this model, there was no significant association between presence of HT and poor outcome (p = 0.0572). Coexisting LA may predict poor functional outcome in patients with acute anterior circulation ILAO independent of other known important outcome predictors such as comorbid state, admission functional deficit, collateral status, hemorrhagic conversion, and treatment modality. Copyright © 2012 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Maciążek-Jurczyk, M.; Sułkowska, A.
2015-02-01
Oxygen metabolism has an important role in the pathogenesis of rheumatoid arthritis (RA). Reactive oxygen species (ROS) are produced in the course of cellular oxidative phosphorylation and by activated phagocytic cells during oxidative bursts, exceed the physiological buffering capacity and result in oxidative stress. ROS result in oxidation of serum albumin, which causes a number of structural changes in the spatial structure, may influence the binding and cause significant drug interactions, particularly in polytherapy. During the oxidation modification of amino acid residues, particularly cysteine and methionine may occur. The aim of the study was to investigate the influence of oxidative stress on human serum albumin (HSA) structure and evaluate of possible alterations in the binding of the drug to oxidized human serum albumin (oHSA). HSA was oxidized by a chloramine-T (CT). CT reacts rapidly with sulfhydryl groups and at pH 7.4 the reaction was monitored by spectroscopic techniques. Modification of free thiol group in the Cys residue in HSA was quantitatively determined by the use of Ellman's reagent. Changes of albumin conformation were examined by comparison of modified (oHSA) and nonmodified human serum albumin (HSA) absorption spectra, emission spectra, red-edge shift (REES) and synchronous spectroscopy. Studies of absorption spectra indicated that changes in the value of absorbance associated with spectral changes in the region of 200-250 nm involve structural alterations in peptide backbone conformation. Synchronous fluorescence spectroscopy technique confirmed changes of position of tryptophanyl and tyrosyl residues fluorescent band caused by CT. Moreover analysis of REES effect allowed to observe structural changes caused by CT in the region of the hydrophobic pocket containing the tryptophanyl residue. Effect of oxidative stress on binding of anti-rheumatic drugs, sulfasalazine (SSZ) and sulindac (SLD) in the high and low affinity binding sites was investigated by spectrofluorescence, ITC and 1H NMR spectroscopy, respectively. SSZ and SLD change the affinity of each other to the binding site in non- and modified human serum albumin. The presence of SLD causes the increase of association constant (Ka) of SSZ-oHSA system and the strength of binding and the stability of the complexes has been observed while in the presence of SSZ a displacement of SLD from the SLD-HSA has been recorded. The analysis of 1H NMR spectral parameters i.e. changes of chemical shifts of the drug indicate that the presence of SSZ and SLD have a mutual influence on changes in the affinity of human serum albumin binding site and this competition takes place not only due to the additional drug but also to the oxidation of HSA.
Woods, Sarah J; Spriet, Mathieu; Safra, Noa; Cissell, Derek D; Borjesson, Dori L
2018-04-23
All categories of pleural effusion subjectively display as soft tissue opacity on computed tomography (CT). Quantitative measurement using Hounsfield units (HU) has the potential to bring additional information regarding the nature of the fluid in a noninvasive way. The purposes of this retrospective cross-sectional analytical study were to compare Hounsfield units of different pleural effusion categories in dogs and cats, assess association between specific cytologic parameters and Hounsfield units, and evaluate the effect of dependent vs. nondependent aspect of the effusion pool on Hounsfield unit. A total of 111 patients (74 dogs and 37 cats) with pleural effusion, that underwent thoracic CT and diagnostic thoracocentesis, were included in the study. Effusions were cytologically categorized as exudate, transudate, modified transudate, hemorrhage, or chyle. Significant differences existed in Hounsfield units between categories in dogs (P < 0.0001) but not in cats (P = 0.334). Canine chylous effusion (6.1 ± 4.7 HU (mean ± standard deviation)) and transudate (5.6 ± 2.0) were significantly lower than exudate (20.3 ± 9.5) and hemorrhage (21.4 ± 9.2). No significant differences were found between modified transudate (13.6 ± 10.3) and other categories. Significant, weak linear correlation was identified in dogs between Hounsfield units and total protein (P = 0.018, R = 0.089), red blood cells (P = 0.021, R = 0.077), and total nucleated cells (P = 0.013, R = 0.089). The Hounsfield units of dependent effusion was not significantly higher than the nondependent effusion, except for canine chylous effusion (P = 0.008). Fourteen Hounsfield units was identified as the most clinically useful threshold: <14 HU identified transudate or chylous effusion with a sensitivity of 100% and a specificity of 69%. A threshold >14 HU had a specificity of 100% and a sensitivity of 69% for identifying exudate, modified transudate, or hemorrhage. © 2018 American College of Veterinary Radiology.
Ability of 3 tanniferous forage legumes to modify quality of milk and Gruyère-type cheese.
Girard, M; Dohme-Meier, F; Wechsler, D; Goy, D; Kreuzer, M; Bee, G
2016-01-01
Condensed tannins (CT) may affect ruminal biohydrogenation of dietary polyunsaturated fatty acids. A feeding experiment was conducted with 24 Holstein cows to evaluate whether diets containing CT from different forage legumes can increase polyunsaturated fatty acids, especially n-3 fatty acid content in milk and cheese, without affecting negatively their physicochemical and sensorial properties. Cows were assigned to 4 treatment groups (n=6) for 52 d, divided into 2 periods: a control period (CoP) and an experimental period (ExP). During the CoP, cows received a basal diet composed of hay, corn silage, ExtruLin (Trinova Handel & Marketing AG, Wangen, Switzerland), concentrate, and alfalfa (AF) in a ratio of 45:25:5:7:18. In the ExP, in 3 of the 4 groups AF was replaced by either sainfoin (SF; 19% CT in dry matter) or 1 of 2 cultivars of birdsfoot trefoil [Polom (BP), 3% CT; Bull (BB), 5% CT]. At the end of each period, milk was collected on 3 consecutive days and analyzed for milk gross composition and fatty acid profile and was processed to Gruyère-type cheese. A trained panel assessed the sensory quality of raw milk and cheese using discriminative and descriptive tests. This experimental design consisting of AF in both the CoP and ExP allowed us to quantify effects due to lactation stage and experimental diets. In both the CoP and ExP, dry matter intake and milk yield did not differ among treatment groups. From the CoP to the ExP, milk urea content was reduced by 23% with SF, remained unchanged with BP, and tended to increase with AF and BB. The odor of the raw BB milk was judged to be different from AF milk. With SF, switching from the CoP to the ExP resulted in a 17% increase of the 18:3n-3 proportion in milk and cheese lipids. In BP cheese, the increase was 3%, whereas it tended to decrease in BB cheese. Additionally, the 20:5n-3 and 22:5n-3 proportions tended to increase in SF cheese from the CoP to the ExP. Compared with the AF cheeses, cheeses from cows fed CT-containing legumes were judged harder and tended to be less adhesive to the palate. In addition, SF and BP cheeses had less rind. In conclusion, feeding SF compared with BB and BP increased the content of 18:3n-3 in the milk and the cheese without a negative effect on flavor of the cheese. Despite a similar CT content, the 2 birdsfoot trefoil cultivars had opposite effects on milk urea and 18:3n-3 deposition, suggesting that, besides the content, the chemical structure may have had an important effect on the CT efficacy. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Mathematical modelling of scanner-specific bowtie filters for Monte Carlo CT dosimetry
NASA Astrophysics Data System (ADS)
Kramer, R.; Cassola, V. F.; Andrade, M. E. A.; de Araújo, M. W. C.; Brenner, D. J.; Khoury, H. J.
2017-02-01
The purpose of bowtie filters in CT scanners is to homogenize the x-ray intensity measured by the detectors in order to improve the image quality and at the same time to reduce the dose to the patient because of the preferential filtering near the periphery of the fan beam. For CT dosimetry, especially for Monte Carlo calculations of organ and tissue absorbed doses to patients, it is important to take the effect of bowtie filters into account. However, material composition and dimensions of these filters are proprietary. Consequently, a method for bowtie filter simulation independent of access to proprietary data and/or to a specific scanner would be of interest to many researchers involved in CT dosimetry. This study presents such a method based on the weighted computer tomography dose index, CTDIw, defined in two cylindrical PMMA phantoms of 16 cm and 32 cm diameter. With an EGSnrc-based Monte Carlo (MC) code, ratios CTDIw/CTDI100,a were calculated for a specific CT scanner using PMMA bowtie filter models based on sigmoid Boltzmann functions combined with a scanner filter factor (SFF) which is modified during calculations until the calculated MC CTDIw/CTDI100,a matches ratios CTDIw/CTDI100,a, determined by measurements or found in publications for that specific scanner. Once the scanner-specific value for an SFF has been found, the bowtie filter algorithm can be used in any MC code to perform CT dosimetry for that specific scanner. The bowtie filter model proposed here was validated for CTDIw/CTDI100,a considering 11 different CT scanners and for CTDI100,c, CTDI100,p and their ratio considering 4 different CT scanners. Additionally, comparisons were made for lateral dose profiles free in air and using computational anthropomorphic phantoms. CTDIw/CTDI100,a determined with this new method agreed on average within 0.89% (max. 3.4%) and 1.64% (max. 4.5%) with corresponding data published by CTDosimetry (www.impactscan.org) for the CTDI HEAD and BODY phantoms, respectively. Comparison with results calculated using proprietary data for the PHILIPS Brilliance 64 scanner showed agreement on average within 2.5% (max. 5.8%) and with data measured for that scanner within 2.1% (max. 3.7%). Ratios of CTDI100,c/CTDI100, p for this study and corresponding data published by CTDosimetry (www.impactscan.org) agree on average within about 11% (max. 28.6%). Lateral dose profiles calculated with the proposed bowtie filter and with proprietary data agreed within 2% (max. 5.9%), and both calculated data agreed within 5.4% (max. 11.2%) with measured results. Application of the proposed bowtie filter and of the exactly modelled filter to human phantom Monte Carlo calculations show agreement on the average within less than 5% (max. 7.9%) for organ and tissue absorbed doses.
Amoroso-Silva, Pablo; De Moraes, Ivaldo Gomes; Marceliano-Alves, Marilia; Bramante, Clovis Monteiro; Zapata, Ronald Ordinola; Hungaro Duarte, Marco Antonio
2018-01-01
This study aimed to describe the morphological and morphometric aspects of fused mandibular second molars with radicular shallow grooves using micro-computed tomography (CT). Eighty-eight mandibular second molars with fused roots were scanned in a micro-CT scanner at a voxel size of 19.6 μm. After reconstruction, only molars without C-shaped roots and presenting shallow radicular grooves were selected. 30 molars were chosen for further analysis. Canal cross-sections were classified according to Fan's modified classification (C1, C2, C3, and C4) and morphometric parameters at the apical region, examination of accessory foramina and tridimensional configuration were evaluated. Three-dimensional reconstructions indicated a higher prevalence of merging type ( n = 22). According to Fan's modified classification, the C4 configuration was predominant in the 3 apical mm. Roundness median values revealed a more round-shaped canals at 3 mm (0.72) than at 2 (0.63) and 1 (0.61) mm from the apex. High values of major and minor diameters were observed in the canals of these evaluated sections. In addition, few accessory apical foramina were observed at 1 and 2 mm from the apex. The average distance between last accessory foramina and the anatomic apex was 1.17 mm. A less complex internal anatomy is found when a mandibular second molar presents fused roots with shallow radicular grooves. The merging type canal was frequently observed. Moreover, the C4 configuration was predominant at a point 3 mm from the apex and presented rounded canals, large apical diameters, and few accessory foramina. The cervical and middle thirds presented C3 and C1 canal configurations most frequently. A minor morphological complexity is found when fused mandibular second molars present shallow radicular grooves.