Sample records for modified integral counting

  1. Incorporating Neutrophil-to-lymphocyte Ratio and Platelet-to-lymphocyte Ratio in Place of Neutrophil Count and Platelet Count Improves Prognostic Accuracy of the International Metastatic Renal Cell Carcinoma Database Consortium Model

    PubMed Central

    Chrom, Pawel; Stec, Rafal; Bodnar, Lubomir; Szczylik, Cezary

    2018-01-01

    Purpose The study investigated whether a replacement of neutrophil count and platelet count by neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) within the International Metastatic Renal Cell Carcinoma Database Consortium (IMDC) model would improve its prognostic accuracy. Materials and Methods This retrospective analysis included consecutive patients with metastatic renal cell carcinoma treated with first-line tyrosine kinase inhibitors. The IMDC and modified-IMDC models were compared using: concordance index (CI), bias-corrected concordance index (BCCI), calibration plots, the Grønnesby and Borgan test, Bayesian Information Criterion (BIC), generalized R2, Integrated Discrimination Improvement (IDI), and continuous Net Reclassification Index (cNRI) for individual risk factors and the three risk groups. Results Three hundred and twenty-one patients were eligible for analyses. The modified-IMDC model with NLR value of 3.6 and PLR value of 157 was selected for comparison with the IMDC model. Both models were well calibrated. All other measures favoured the modified-IMDC model over the IMDC model (CI, 0.706 vs. 0.677; BCCI, 0.699 vs. 0.671; BIC, 2,176.2 vs. 2,190.7; generalized R2, 0.238 vs. 0.202; IDI, 0.044; cNRI, 0.279 for individual risk factors; and CI, 0.669 vs. 0.641; BCCI, 0.669 vs. 0.641; BIC, 2,183.2 vs. 2,198.1; generalized R2, 0.163 vs. 0.123; IDI, 0.045; cNRI, 0.165 for the three risk groups). Conclusion Incorporation of NLR and PLR in place of neutrophil count and platelet count improved prognostic accuracy of the IMDC model. These findings require external validation before introducing into clinical practice. PMID:28253564

  2. Incorporating Neutrophil-to-lymphocyte Ratio and Platelet-to-lymphocyte Ratio in Place of Neutrophil Count and Platelet Count Improves Prognostic Accuracy of the International Metastatic Renal Cell Carcinoma Database Consortium Model.

    PubMed

    Chrom, Pawel; Stec, Rafal; Bodnar, Lubomir; Szczylik, Cezary

    2018-01-01

    The study investigated whether a replacement of neutrophil count and platelet count by neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) within the International Metastatic Renal Cell Carcinoma Database Consortium (IMDC) model would improve its prognostic accuracy. This retrospective analysis included consecutive patients with metastatic renal cell carcinoma treated with first-line tyrosine kinase inhibitors. The IMDC and modified-IMDC models were compared using: concordance index (CI), bias-corrected concordance index (BCCI), calibration plots, the Grønnesby and Borgan test, Bayesian Information Criterion (BIC), generalized R 2 , Integrated Discrimination Improvement (IDI), and continuous Net Reclassification Index (cNRI) for individual risk factors and the three risk groups. Three hundred and twenty-one patients were eligible for analyses. The modified-IMDC model with NLR value of 3.6 and PLR value of 157 was selected for comparison with the IMDC model. Both models were well calibrated. All other measures favoured the modified-IMDC model over the IMDC model (CI, 0.706 vs. 0.677; BCCI, 0.699 vs. 0.671; BIC, 2,176.2 vs. 2,190.7; generalized R 2 , 0.238 vs. 0.202; IDI, 0.044; cNRI, 0.279 for individual risk factors; and CI, 0.669 vs. 0.641; BCCI, 0.669 vs. 0.641; BIC, 2,183.2 vs. 2,198.1; generalized R 2 , 0.163 vs. 0.123; IDI, 0.045; cNRI, 0.165 for the three risk groups). Incorporation of NLR and PLR in place of neutrophil count and platelet count improved prognostic accuracy of the IMDC model. These findings require external validation before introducing into clinical practice.

  3. A Comparison of the OSHA Modified NIOSH Physical and Chemical Analytical Method (P and CAM) 304 and the Dust Trak Photometric Aerosol Sampler for 0-Chlorobenzylidine Malonitrile

    DTIC Science & Technology

    2013-04-02

    photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method to determine correlation between the two...study compared the non-specific, rapid photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method...mask confidence training (27) . This study will compare a direct reading, non-specific photometric particle count instrument (DustTrak TSI Model

  4. Modified combination of platelet count and neutrophil "to" lymphocyte ratio as a prognostic factor in patients with advanced head and neck cancer.

    PubMed

    Nakayama, Masahiro; Gosho, Masahiko; Hirose, Yuki; Nishimura, Bungo; Tanaka, Shuho; Tabuchi, Keiji; Okubo, Hideki; Wada, Tetsuro; Hara, Akira

    2018-06-01

    We evaluated the prognostic potential of the combination of platelet count and neutrophil to lymphocyte ratio (COP-NLR) in patients with advanced head and neck cancer. We proposed a modified COP-NLR scoring system defined as follows: score 0 (platelet count level <300 × 10 9 /L and NLR <3); score 1 (platelet count level ≥300 × 10 9 /L and NLR <3); and score 2 (NLR ≥3). We assessed whether the modified scoring system had better performance as an indicator of prognosis than the existing COP-NLR scoring system (original and 4-group scores). A total of 248 patients were enrolled. The Akaike Information Criterion value with the modified COP-NLR score was the smallest among the 3 models. The 3-year survival rates according to the modified COP-NLR scores of 0, 1, and 2 were 80.6%, 59.9%, and 23.8%, respectively. The modified COP-NLR score is a useful prognostic marker in patients with advanced head and neck cancer. © 2018 Wiley Periodicals, Inc.

  5. Modeling zero-modified count and semicontinuous data in health services research part 2: case studies.

    PubMed

    Neelon, Brian; O'Malley, A James; Smith, Valerie A

    2016-11-30

    This article is the second installment of a two-part tutorial on the analysis of zero-modified count and semicontinuous data. Part 1, which appears as a companion piece in this issue of Statistics in Medicine, provides a general background and overview of the topic, with particular emphasis on applications to health services research. Here, we present three case studies highlighting various approaches for the analysis of zero-modified data. The first case study describes methods for analyzing zero-inflated longitudinal count data. Case study 2 considers the use of hurdle models for the analysis of spatiotemporal count data. The third case study discusses an application of marginalized two-part models to the analysis of semicontinuous health expenditure data. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Health-aware Model Predictive Control of Pasteurization Plant

    NASA Astrophysics Data System (ADS)

    Karimi Pour, Fatemeh; Puig, Vicenç; Ocampo-Martinez, Carlos

    2017-01-01

    In order to optimize the trade-off between components life and energy consumption, the integration of a system health management and control modules is required. This paper proposes the integration of model predictive control (MPC) with a fatigue estimation approach that minimizes the damage of the components of a pasteurization plant. The fatigue estimation is assessed with the rainflow counting algorithm. Using data from this algorithm, a simplified model that characterizes the health of the system is developed and integrated with MPC. The MPC controller objective is modified by adding an extra criterion that takes into account the accumulated damage. But, a steady-state offset is created by adding this extra criterion. Finally, by including an integral action in the MPC controller, the steady-state error for regulation purpose is eliminated. The proposed control scheme is validated in simulation using a simulator of a utility-scale pasteurization plant.

  7. Children's Counting Strategies for Time Quantification and Integration.

    ERIC Educational Resources Information Center

    Wilkening, Friedrich; And Others

    1987-01-01

    Investigated whether and how children age 5 to 7 employed counting to measure and integrate the duration of two events, which were accompanied by metronome beats for half the children. The rhythm enhanced use of counting in younger children. By age 7, most counted spontaneously, using sensible counting strategies. (SKC)

  8. Modeling zero-modified count and semicontinuous data in health services research Part 1: background and overview.

    PubMed

    Neelon, Brian; O'Malley, A James; Smith, Valerie A

    2016-11-30

    Health services data often contain a high proportion of zeros. In studies examining patient hospitalization rates, for instance, many patients will have no hospitalizations, resulting in a count of zero. When the number of zeros is greater or less than expected under a standard count model, the data are said to be zero modified relative to the standard model. A similar phenomenon arises with semicontinuous data, which are characterized by a spike at zero followed by a continuous distribution with positive support. When analyzing zero-modified count and semicontinuous data, flexible mixture distributions are often needed to accommodate both the excess zeros and the typically skewed distribution of nonzero values. Various models have been introduced over the past three decades to accommodate such data, including hurdle models, zero-inflated models, and two-part semicontinuous models. This tutorial describes recent modeling strategies for zero-modified count and semicontinuous data and highlights their role in health services research studies. Part 1 of the tutorial, presented here, provides a general overview of the topic. Part 2, appearing as a companion piece in this issue of Statistics in Medicine, discusses three case studies illustrating applications of the methods to health services research. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Adaptive Search through Constraint Violations

    DTIC Science & Technology

    1990-01-01

    underly counting (Gelman & Gallistel , 1978; Gelman & Meck, 1986). Modifying slightly the analysis by Gelman and Gallistel (1978), we identify three...understanding of counting, Gelman and Gallistel (1978) invented two non-standard counting tasks, ordered counting, in which the objects are counted In... Gallistel , 1978; Gelman & Meck, 1986). The most plausible explanation for this flexibility is that children can derive the control knowledge for the

  10. The diabetes nutrition education study randomized controlled trial: A comparative effectiveness study of approaches to nutrition in diabetes self-management education.

    PubMed

    Bowen, Michael E; Cavanaugh, Kerri L; Wolff, Kathleen; Davis, Dianne; Gregory, Rebecca P; Shintani, Ayumi; Eden, Svetlana; Wallston, Ken; Elasy, Tom; Rothman, Russell L

    2016-08-01

    To compare the effectiveness of different approaches to nutrition education in diabetes self-management education and support (DSME/S). We randomized 150 adults with type 2 diabetes to either certified diabetes educator (CDE)-delivered DSME/S with carbohydrate gram counting or the modified plate method versus general health education. The primary outcome was change in HbA1C over 6 months. At 6 months, HbA1C improved within the plate method [-0.83% (-1.29, -0.33), P<0.001] and carbohydrate counting [-0.63% (-1.03, -0.18), P=0.04] groups but not the control group [P=0.34]. Change in HbA1C from baseline between the control and intervention groups was not significant at 6 months (carbohydrate counting, P=0.36; modified plate method, P=0.08). In a pre-specified subgroup analysis of patients with a baseline HbA1C 7-10%, change in HbA1C from baseline improved in the carbohydrate counting [-0.86% (-1.47, -0.26), P=0.006] and plate method groups [-0.76% (-1.33, -0.19), P=0.01] compared to controls. CDE-delivered DSME/S focused on carbohydrate counting or the modified plate method improved glycemic control in patients with an initial HbA1C between 7 and 10%. Both carbohydrate counting and the modified plate method improve glycemic control as part of DSME/S. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. A comparison of artificial compressibility and fractional step methods for incompressible flow computations

    NASA Technical Reports Server (NTRS)

    Chan, Daniel C.; Darian, Armen; Sindir, Munir

    1992-01-01

    We have applied and compared the efficiency and accuracy of two commonly used numerical methods for the solution of Navier-Stokes equations. The artificial compressibility method augments the continuity equation with a transient pressure term and allows one to solve the modified equations as a coupled system. Due to its implicit nature, one can have the luxury of taking a large temporal integration step at the expense of higher memory requirement and larger operation counts per step. Meanwhile, the fractional step method splits the Navier-Stokes equations into a sequence of differential operators and integrates them in multiple steps. The memory requirement and operation count per time step are low, however, the restriction on the size of time marching step is more severe. To explore the strengths and weaknesses of these two methods, we used them for the computation of a two-dimensional driven cavity flow with Reynolds number of 100 and 1000, respectively. Three grid sizes, 41 x 41, 81 x 81, and 161 x 161 were used. The computations were considered after the L2-norm of the change of the dependent variables in two consecutive time steps has fallen below 10(exp -5).

  12. Exercise Improves Cognition in Parkinson’s Disease: the PRET-PD Randomized Clinical Trial

    PubMed Central

    David, Fabian J.; Robichaud, Julie A.; Leurgans, Sue E.; Poon, Cynthia; Kohrt, Wendy M.; Goldman, Jennifer G.; Comella, Cynthia L.; Vaillancourt, David E.; Corcos, Daniel M.

    2015-01-01

    Background This paper reports on the findings of the effect of two structured exercise interventions on secondary cognitive outcomes which were gathered as part of the Progressive Resistance Exercise Training in Parkinson’s disease randomized controlled trial. Methods This study was a prospective, parallel-group, single-center trial. Fifty-one non-demented patients with mild-to-moderate Parkinson’s disease were randomly assigned either to modified Fitness Counts or to Progressive Resistance Exercise, and were followed for 24 months. Cognitive outcomes were the Digit Span, Stroop, and Brief Test of Attention. Results Eighteen patients in modified Fitness Counts and 20 patients in Progressive Resistance Exercise completed the trial. At 12 and at 24 months no differences between groups were observed. At 12 months, relative to baseline, modified Fitness Counts improved on the Digit Span (estimated change, 0.3; Inter-Quartile Range, 0, 0.7; p=0.04) and Stroop (0.3; 0, 0.6; p=0.04), and Progressive Resistance Exercise improved only on the Digit Span (0.7; 0.3, 1; p<0.01). At 24 months, relative to baseline, modified Fitness Counts improved on the Digit Span (0.7; 0.3, 1.7; p<0.01) and Stroop (0.3; 0.1, 0.5; p=0.03), while Progressive Resistance Exercise improved on the Digit Span (0.5; 0.2, 0.8; p<0.01), Stroop (0.2; −0.1, 0.6; p=0.048), and Brief Test of Attention (0.3; 0, 0.8; p=0.048). No neurologic or cognitive adverse events were seen. Conclusions This study provides Class IV level of evidence that 24 months of Progressive Resistance Exercise or modified Fitness Counts may improve attention and working memory in non-demented patients with mild-to-moderate Parkinson’s disease. PMID:26148003

  13. Monitoring Microbial Numbers in Food by Density Centrifugation

    PubMed Central

    Basel, Richard M.; Richter, Edward R.; Banwart, George J.

    1983-01-01

    Some foods contain low numbers of microbes that may be difficult to enumerate by the plate count method due to small food particles that interfere with the counting of colonies. Ludox colloidal silicon was coated with reducing agents to produce a nontoxic density material. Food homogenates were applied to a layered 10 and 80% mixture of modified Ludox and centrifuged at low speed. The top and bottom of the tube contained the food material, and the Ludox-containing portion was evaluated by conventional pour plate techniques. Plate counts of the Ludox mixture agreed with plate counts of the food homogenate alone. The absence of small food particles from pour plates resulted in a plate that was more easily read than pour plates of the homogenate alone. Modified Ludox was evaluated for its effect on bacteria at 4°C during a 24-h incubation period. No inhibition was observed. This method is applicable to food products, such as doughnuts, spices, tomato products, and meat, in which small food particles often interfere with routine plate counts or low dilution may inhibit colony formation. Inhibitory substances can be removed from spices, resulting in higher counts. Ludox is more economical than similar products, such as Percoll. Modified Ludox is easily rendered nontoxic by the addition of common laboratory reagents. In addition, the mixture is compatible with microbiological media. PMID:6303217

  14. Pulse pileup statistics for energy discriminating photon counting x-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir

    Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less

  15. On-Line Identification of Simulation Examples for Forgetting Methods to Track Time Varying Parameters Using the Alternative Covariance Matrix in Matlab

    NASA Astrophysics Data System (ADS)

    Vachálek, Ján

    2011-12-01

    The paper compares the abilities of forgetting methods to track time varying parameters of two different simulated models with different types of excitation. The observed parameters in the simulations are the integral sum of the Euclidean norm, deviation of the parameter estimates from their true values and a selected band prediction error count. As supplementary information, we observe the eigenvalues of the covariance matrix. In the paper we used a modified method of Regularized Exponential Forgetting with Alternative Covariance Matrix (REFACM) along with Directional Forgetting (DF) and three standard regularized methods.

  16. Edge detection of optical subaperture image based on improved differential box-counting method

    NASA Astrophysics Data System (ADS)

    Li, Yi; Hui, Mei; Liu, Ming; Dong, Liquan; Kong, Lingqin; Zhao, Yuejin

    2018-01-01

    Optical synthetic aperture imaging technology is an effective approach to improve imaging resolution. Compared with monolithic mirror system, the image of optical synthetic aperture system is often more complex at the edge, and as a result of the existence of gap between segments, which makes stitching becomes a difficult problem. So it is necessary to extract the edge of subaperture image for achieving effective stitching. Fractal dimension as a measure feature can describe image surface texture characteristics, which provides a new approach for edge detection. In our research, an improved differential box-counting method is used to calculate fractal dimension of image, then the obtained fractal dimension is mapped to grayscale image to detect edges. Compared with original differential box-counting method, this method has two improvements as follows: by modifying the box-counting mechanism, a box with a fixed height is replaced by a box with adaptive height, which solves the problem of over-counting the number of boxes covering image intensity surface; an image reconstruction method based on super-resolution convolutional neural network is used to enlarge small size image, which can solve the problem that fractal dimension can't be calculated accurately under the small size image, and this method may well maintain scale invariability of fractal dimension. The experimental results show that the proposed algorithm can effectively eliminate noise and has a lower false detection rate compared with the traditional edge detection algorithms. In addition, this algorithm can maintain the integrity and continuity of image edge in the case of retaining important edge information.

  17. Selecting a distributional assumption for modelling relative densities of benthic macroinvertebrates

    USGS Publications Warehouse

    Gray, B.R.

    2005-01-01

    The selection of a distributional assumption suitable for modelling macroinvertebrate density data is typically challenging. Macroinvertebrate data often exhibit substantially larger variances than expected under a standard count assumption, that of the Poisson distribution. Such overdispersion may derive from multiple sources, including heterogeneity of habitat (historically and spatially), differing life histories for organisms collected within a single collection in space and time, and autocorrelation. Taken to extreme, heterogeneity of habitat may be argued to explain the frequent large proportions of zero observations in macroinvertebrate data. Sampling locations may consist of habitats defined qualitatively as either suitable or unsuitable. The former category may yield random or stochastic zeroes and the latter structural zeroes. Heterogeneity among counts may be accommodated by treating the count mean itself as a random variable, while extra zeroes may be accommodated using zero-modified count assumptions, including zero-inflated and two-stage (or hurdle) approaches. These and linear assumptions (following log- and square root-transformations) were evaluated using 9 years of mayfly density data from a 52 km, ninth-order reach of the Upper Mississippi River (n = 959). The data exhibited substantial overdispersion relative to that expected under a Poisson assumption (i.e. variance:mean ratio = 23 ??? 1), and 43% of the sampling locations yielded zero mayflies. Based on the Akaike Information Criterion (AIC), count models were improved most by treating the count mean as a random variable (via a Poisson-gamma distributional assumption) and secondarily by zero modification (i.e. improvements in AIC values = 9184 units and 47-48 units, respectively). Zeroes were underestimated by the Poisson, log-transform and square root-transform models, slightly by the standard negative binomial model but not by the zero-modified models (61%, 24%, 32%, 7%, and 0%, respectively). However, the zero-modified Poisson models underestimated small counts (1 ??? y ??? 4) and overestimated intermediate counts (7 ??? y ??? 23). Counts greater than zero were estimated well by zero-modified negative binomial models, while counts greater than one were also estimated well by the standard negative binomial model. Based on AIC and percent zero estimation criteria, the two-stage and zero-inflated models performed similarly. The above inferences were largely confirmed when the models were used to predict values from a separate, evaluation data set (n = 110). An exception was that, using the evaluation data set, the standard negative binomial model appeared superior to its zero-modified counterparts using the AIC (but not percent zero criteria). This and other evidence suggest that a negative binomial distributional assumption should be routinely considered when modelling benthic macroinvertebrate data from low flow environments. Whether negative binomial models should themselves be routinely examined for extra zeroes requires, from a statistical perspective, more investigation. However, this question may best be answered by ecological arguments that may be specific to the sampled species and locations. ?? 2004 Elsevier B.V. All rights reserved.

  18. Effect of vacuum and modified atmosphere packaging on microbiological properties of cold-smoked trout

    NASA Astrophysics Data System (ADS)

    Đorđević, J.; Pavlićević, N.; Bošković, M.; Janjić, J.; Glišić, M.; Starčević, M.; Baltić, M. Ž.

    2017-09-01

    Because of the importance of different packaging methods for the extension of fish shelf life, as a highly perishable food, the aim of the present study was to examine the effect of vacuum and modified atmosphere packaging on the total Enterobacteriaceae and lactic acid bacteria counts of cold-smoked Salmon trout (Oncorhynchus mykiss) stored at 3°C during six weeks. Trout fillets were vacuumed packaged (VP) or packaged in one of two different modified atmospheres, with gas ratio of 50%CO2/50%N2 (MAP1) and 90%CO2/10%N2 (MAP2) and analysed on days 0, 7, 14, 21, 28, 35 and 42. Both the total Enterobacteriaceae and total lactic acid bacteria counts increased in the trout fillets in all packaging types during storage. A significantly lower total Enterobacteriaceae count was determined in the MAP fish compared to the VP fish, with the weakest growth rate and lowest numbers attained in MAP2 fillets. The lactic acid bacteria count was higher in trout packaged in MAP compared to VP, with the highest number in the MAP with 90% CO2 (MAP2).

  19. Excessive bleeding predictors after cardiac surgery in adults: integrative review.

    PubMed

    Lopes, Camila Takao; Dos Santos, Talita Raquel; Brunori, Evelise Helena Fadini Reis; Moorhead, Sue A; Lopes, Juliana de Lima; Barros, Alba Lucia Bottura Leite de

    2015-11-01

    To integrate literature data on the predictors of excessive bleeding after cardiac surgery in adults. Perioperative nursing care requires awareness of the risk factors for excessive bleeding after cardiac surgery to assure vigilance prioritising and early correction of those that are modifiable. Integrative literature review. Articles were searched in seven databases. Seventeen studies investigating predictive factors for excessive bleeding after open-heart surgery from 2004-2014 were included. Predictors of excessive bleeding after cardiac surgery were: Patient-related: male gender, higher preoperative haemoglobin levels, lower body mass index, diabetes mellitus, impaired left ventricular function, lower amount of prebypass thrombin generation, lower preoperative platelet counts, decreased preoperative platelet aggregation, preoperative platelet inhibition level >20%, preoperative thrombocytopenia and lower preoperative fibrinogen concentration. Procedure-related: the operating surgeon, coronary artery bypass surgery with three or more bypasses, use of the internal mammary artery, duration of surgery, increased cross-clamp time, increased cardiopulmonary bypass time, lower intraoperative core body temperature and bypass-induced haemostatic disorders. Postoperative: fibrinogen levels and metabolic acidosis. Patient-related, procedure-related and postoperative predictors of excessive bleeding after cardiac surgery were identified. The predictors summarised in this review can be used for risk stratification of excessive bleeding after cardiac surgery. Assessment, documentation and case reporting can be guided by awareness of these factors, so that postoperative vigilance can be prioritised. Timely identification and correction of the modifiable factors can be facilitated. © 2015 John Wiley & Sons Ltd.

  20. Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

    NASA Astrophysics Data System (ADS)

    Zhang, Guoqing; Lina, Liu

    2018-02-01

    An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.

  1. 75 FR 36114 - Notice of Inventory Completion: U.S. Department of Defense, Army Corps of Engineers, Walla Walla...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-24

    .... The six counted objects are one core, two unidentified ground stone items, one iron container, and two... funerary objects are one counted object and seven lots of objects, which are one piece of modified bone... identified. The seven associated funerary objects are one counted object and six lots of objects, which are...

  2. Forecasting Emergency Department Crowding: An External, Multi-Center Evaluation

    PubMed Central

    Hoot, Nathan R.; Epstein, Stephen K.; Allen, Todd L.; Jones, Spencer S.; Baumlin, Kevin M.; Chawla, Neal; Lee, Anna T.; Pines, Jesse M.; Klair, Amandeep K.; Gordon, Bradley D.; Flottemesch, Thomas J.; LeBlanc, Larry J.; Jones, Ian; Levin, Scott R.; Zhou, Chuan; Gadd, Cynthia S.; Aronsky, Dominik

    2009-01-01

    Objective To apply a previously described tool to forecast ED crowding at multiple institutions, and to assess its generalizability for predicting the near-future waiting count, occupancy level, and boarding count. Methods The ForecastED tool was validated using historical data from five institutions external to the development site. A sliding-window design separated the data for parameter estimation and forecast validation. Observations were sampled at consecutive 10-minute intervals during 12 months (n = 52,560) at four sites and 10 months (n = 44,064) at the fifth. Three outcome measures – the waiting count, occupancy level, and boarding count – were forecast 2, 4, 6, and 8 hours beyond each observation, and forecasts were compared to observed data at corresponding times. The reliability and calibration were measured following previously described methods. After linear calibration, the forecasting accuracy was measured using the median absolute error (MAE). Results The tool was successfully used for five different sites. Its forecasts were more reliable, better calibrated, and more accurate at 2 hours than at 8 hours. The reliability and calibration of the tool were similar between the original development site and external sites; the boarding count was an exception, which was less reliable at four out of five sites. Some variability in accuracy existed among institutions; when forecasting 4 hours into the future, the MAE of the waiting count ranged between 0.6 and 3.1 patients, the MAE of the occupancy level ranged between 9.0 and 14.5% of beds, and the MAE of the boarding count ranged between 0.9 and 2.7 patients. Conclusion The ForecastED tool generated potentially useful forecasts of input and throughput measures of ED crowding at five external sites, without modifying the underlying assumptions. Noting the limitation that this was not a real-time validation, ongoing research will focus on integrating the tool with ED information systems. PMID:19716629

  3. Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

    PubMed

    Ding, Huanjun; Molloi, Sabee

    2012-08-07

    A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio of the dual energy image with respect to the square root of mean glandular dose, was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. For an average sized 4.5 cm thick breast, the FOM was maximized with a tube voltage of 46 kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (∼32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique.

  4. Zero adjusted models with applications to analysing helminths count data.

    PubMed

    Chipeta, Michael G; Ngwira, Bagrey M; Simoonga, Christopher; Kazembe, Lawrence N

    2014-11-27

    It is common in public health and epidemiology that the outcome of interest is counts of events occurrence. Analysing these data using classical linear models is mostly inappropriate, even after transformation of outcome variables due to overdispersion. Zero-adjusted mixture count models such as zero-inflated and hurdle count models are applied to count data when over-dispersion and excess zeros exist. Main objective of the current paper is to apply such models to analyse risk factors associated with human helminths (S. haematobium) particularly in a case where there's a high proportion of zero counts. The data were collected during a community-based randomised control trial assessing the impact of mass drug administration (MDA) with praziquantel in Malawi, and a school-based cross sectional epidemiology survey in Zambia. Count data models including traditional (Poisson and negative binomial) models, zero modified models (zero inflated Poisson and zero inflated negative binomial) and hurdle models (Poisson logit hurdle and negative binomial logit hurdle) were fitted and compared. Using Akaike information criteria (AIC), the negative binomial logit hurdle (NBLH) and zero inflated negative binomial (ZINB) showed best performance in both datasets. With regards to zero count capturing, these models performed better than other models. This paper showed that zero modified NBLH and ZINB models are more appropriate methods for the analysis of data with excess zeros. The choice between the hurdle and zero-inflated models should be based on the aim and endpoints of the study.

  5. Investigation of bicycle and pedestrian continuous and short duration count technologies in Oregon : final report : SPR 772.

    DOT National Transportation Integrated Search

    2016-05-01

    While motorized traffic counts are systematic and comprehensive, bicycle and pedestrian counts are : often unknown or inaccurate. This research presents recommendations to increase bicycle and : pedestrian count accuracy while integrating bicycle and...

  6. Progress on the Use of Combined Analog and Photon Counting Detection for Raman Lidar

    NASA Technical Reports Server (NTRS)

    Newsom, Rob; Turner, Dave; Clayton, Marian; Ferrare, Richard

    2008-01-01

    The Atmospheric Radiation Measurement (ARM) program Raman Lidar (CARL) was upgraded in 2004 with a new data system that provides simultaneous measurements of both the photomultiplier analog output voltage and photon counts. The so-called merge value added procedure (VAP) was developed to combine the analog and count-rate signals into a single signal with improved dynamic range. Earlier versions of this VAP tended to cause unacceptably large biases in the water vapor mixing ratio during the daytime as a result of improper matching between the analog and count-rate signals in the presence of elevated solar background levels. We recently identified several problems and tested a modified version of the merge VAP by comparing profiles of water vapor mixing ratio derived from CARL with simultaneous sonde data over a six month period. We show that the modified merge VAP significantly reduces the daytime bias, and results in mean differences that are within approximately 1% for both nighttime and daytime measurements.

  7. A double-fibre Fabry-Perot sensor based on modified fringe counting and direct phase demodulation

    NASA Astrophysics Data System (ADS)

    Li, M.; Tong, B.; Arsad, N.; Guo, J. J.

    2013-09-01

    A modified double-fibre Fabry-Perot cavity is developed for determination of the fringe moving direction and higher sensitivity in applications of liquid level and displacement sensors. Two fibres are integrated into a silica ferrule where the ends of the two fibres in the ferrule serve as the front surfaces of the Fabry-Perot cavities, and a diaphragm, which is replaced by a moving mirror for measurement of displacement, serves as the rear surface for both cavities in liquid level sensing. Our design has no strict requirements for a specific phase difference between the two optical paths, just a constant difference resulting from the processing error between the two fibre end positions rather than a precise optical path difference of λ/8 to judge the pattern shift direction. Experimental results demonstrate the feasibility of this approach to determining the fringe moving direction, a displacement sensitivity of 3 µm and good linearity for both applications.

  8. The effect of silver or gallium doped titanium against the multidrug resistant Acinetobacter baumannii.

    PubMed

    Cochis, A; Azzimonti, B; Della Valle, C; De Giglio, E; Bloise, N; Visai, L; Cometa, S; Rimondini, L; Chiesa, R

    2016-02-01

    Implant-related infection of biomaterials is one of the main causes of arthroplasty and osteosynthesis failure. Bacteria, such as the rapidly-emerging Multi Drug Resistant (MDR) pathogen Acinetobacter Baumannii, initiate the infection by adhering to biomaterials and forming a biofilm. Since the implant surface plays a crucial role in early bacterial adhesion phases, titanium was electrochemically modified by an Anodic Spark Deposition (ASD) treatment, developed previously and thought to provide osseo-integrative properties. In this study, the treatment was modified to insert gallium or silver onto the titanium surface, to provide antibacterial properties. The material was characterized morphologically, chemically, and mechanically; biological properties were investigated by direct cytocompatibility assay, Alkaline Phosphatase (ALP) activity, Scanning Electron Microscopy (SEM), and Immunofluorescent (IF) analysis; antibacterial activity was determined by counting Colony Forming Units, and viability assay. The various ASD-treated surfaces showed similar morphology, micrometric pore size, and uniform pore distribution. Of the treatments studied, gallium-doped specimens showed the best ALP synthesis and antibacterial properties. This study demonstrates the possibility of successfully doping the surface of titanium with gallium or silver, using the ASD technique; this approach can provide antibacterial properties and maintain high osseo-integrative potential. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Integrating chronological uncertainties for annually laminated lake sediments using layer counting, independent chronologies and Bayesian age modelling (Lake Ohau, South Island, New Zealand)

    NASA Astrophysics Data System (ADS)

    Vandergoes, Marcus J.; Howarth, Jamie D.; Dunbar, Gavin B.; Turnbull, Jocelyn C.; Roop, Heidi A.; Levy, Richard H.; Li, Xun; Prior, Christine; Norris, Margaret; Keller, Liz D.; Baisden, W. Troy; Ditchburn, Robert; Fitzsimons, Sean J.; Bronk Ramsey, Christopher

    2018-05-01

    Annually resolved (varved) lake sequences are important palaeoenvironmental archives as they offer a direct incremental dating technique for high-frequency reconstruction of environmental and climate change. Despite the importance of these records, establishing a robust chronology and quantifying its precision and accuracy (estimations of error) remains an essential but challenging component of their development. We outline an approach for building reliable independent chronologies, testing the accuracy of layer counts and integrating all chronological uncertainties to provide quantitative age and error estimates for varved lake sequences. The approach incorporates (1) layer counts and estimates of counting precision; (2) radiometric and biostratigrapic dating techniques to derive independent chronology; and (3) the application of Bayesian age modelling to produce an integrated age model. This approach is applied to a case study of an annually resolved sediment record from Lake Ohau, New Zealand. The most robust age model provides an average error of 72 years across the whole depth range. This represents a fractional uncertainty of ∼5%, higher than the <3% quoted for most published varve records. However, the age model and reported uncertainty represent the best fit between layer counts and independent chronology and the uncertainties account for both layer counting precision and the chronological accuracy of the layer counts. This integrated approach provides a more representative estimate of age uncertainty and therefore represents a statistically more robust chronology.

  10. The effects of age on associations between markers of HIV progression and markers of metabolic function including albumin, haemoglobin and lipid concentrations.

    PubMed

    Samuel, M; Jose, S; Winston, A; Nelson, M; Johnson, M; Chadwick, D; Fisher, M; Leen, C; Gompels, M; Gilson, R; Post, F A; Hay, P; Sabin, C A

    2014-05-01

    We investigated whether age modified associations between markers of HIV progression, CD4 T lymphocyte count and HIV RNA viral load (VL), and the following markers of metabolic function: albumin, haemoglobin, high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and total cholesterol (TC). A retrospective analysis of data from the United Kingdom Collaborative HIV Cohort was carried out. Analyses were limited to antiretroviral-naïve subjects to focus on the impact of HIV disease itself. A total of 16670 subjects were included in the analysis. Multilevel linear regression models assessed associations between CD4 count/VL and each of the outcomes. Statistical tests for interactions assessed whether associations differed among age groups. After adjustment for gender and ethnicity, there was evidence that lower CD4 count and higher VL were associated with lower TC, LDL-C, haemoglobin and albumin concentrations but higher triglyceride concentrations. Age modified associations between CD4 count and albumin (P < 0.001) and haemoglobin (P = 0.001), but not between CD4 count and HDL-C, LDL-C and TC, or VL and any outcome. Among participants aged < 30, 30-50 and > 50 years, a 50 cells/μL lower CD4 count correlated with a 2.4 [95% confidence interval (CI) 1.7-3.0], 3.6 (95% CI 3.2-4.0) and 5.1 (95% CI 4.0-6.1) g/L lower haemoglobin concentration and a 0.09 (95% CI 0.07-0.11), 0.12 (95% CI 0.11-0.13) and 0.16 (95% CI 0.13-0.19) g/L lower albumin concentration, respectively. We present evidence that age modifies associations between CD4 count and plasma albumin and haemoglobin levels. A given reduction in CD4 count was associated with a greater reduction in haemoglobin and albumin concentrations among older people living with HIV. These findings increase our understanding of how the metabolic impact of HIV is influenced by age. © 2013 The Authors. HIV Medicine published by John Wiley & Sons Ltd on behalf of British HIV Association.

  11. Anticlostridial agent 8-hydroxyquinoline improves the isolation of faecal bifidobacteria on modified Wilkins-Chalgren agar with mupirocin.

    PubMed

    Novakova, J; Vlkova, E; Salmonova, H; Pechar, R; Rada, V; Kokoska, L

    2016-04-01

    The need for suitable selective cultivation media for the isolation of Bifidobacterium spp. continues to be a real concern in the field of intestinal microbiology. Isolation of bifidobacteria from human and animal faecal samples using selective agar plating may be problematic especially in samples with increased clostridial counts than bifidobacterial counts. Due to the absence of anticlostridial agents in existing selective media, clostridia can displace bifidobacteria resulting in incorrect estimation of their counts. Therefore, we supplemented the existing selective medium 'modified Wilkins Chalgren agar with mupirocin' (MWM) with 90 mg l(-1) of 8-hydroxyquinoline (8HQ), which was recently proved to act selectively against clostridia. The newly composed 'modified Wilkins-Chalgren agar with 8HQ' (MWMQ) was tested on pure bifidobacterial and clostridial strains, their mixtures, and using faecal samples of mammalian origin; its selectivity was evaluated by genus-specific identification of isolates. The results demonstrated that the presence of 8HQ in this agar eliminated the growth of nonbifidobacterial strains on MWMQ compared to that on MWM, whereas the recovery of bifidobacterial counts was at satisfactory levels. In conclusion, MWMQ could be recommended for bifidobacterial isolation from human and animal faeces especially when bifidobacteria are not numerically dominant and there are chances of clostridial contamination. Routine isolation of bifidobacteria from mammalian faeces does not use a reliable selective agar with an anticlostridial agent. Overgrowth of clostridia may result in incorrect estimation of bifidobacterial counts. Thus, in order to improve the selectivity of existing media for bifidobacterial isolation, we chose the modified Wilkins-Chalgren agar with mupirocin and supplemented it with 8-hydroxyquinoline (8HQ), a molecule that shows anticlostridial activity without affecting the growth of bifidobacteria. This newly composed medium showed enhanced selectivity and specificity compared to the original medium and therefore, can be recommended for the isolation of bifidobacteria from mammal faeces. © 2016 The Society for Applied Microbiology.

  12. Characterization of Sphinx1 ASIC X-ray detector using photon counting and charge integration

    NASA Astrophysics Data System (ADS)

    Habib, A.; Arques, M.; Moro, J.-L.; Accensi, M.; Stanchina, S.; Dupont, B.; Rohr, P.; Sicard, G.; Tchagaspanian, M.; Verger, L.

    2018-01-01

    Sphinx1 is a novel pixel architecture adapted for X-ray imaging, it detects radiation by photon counting and charge integration. In photon counting mode, each photon is compensated by one or more counter-charges typically consisting of 100 electrons (e-) each. The number of counter-charges required gives a measure of the incoming photon energy, thus allowing spectrometric detection. Pixels can also detect radiation by integrating the charges deposited by all incoming photons during one image frame and converting this analog value into a digital response with a 100 electrons least significant bit (LSB), based on the counter-charge concept. A proof of concept test chip measuring 5 mm × 5 mm, with 200 μm × 200 μm pixels has been produced and characterized. This paper provides details on the architecture and the counter-charge design; it also describes the two modes of operation: photon counting and charge integration. The first performance measurements for this test chip are presented. Noise was found to be ~80 e-rms in photon counting mode with a power consumption of only 0.9 μW/pixel for the static analog part and 0.3 μW/pixel for the static digital part.

  13. The sensitivity of direct faecal examination, direct faecal flotation, modified centrifugal faecal flotation and centrifugal sedimentation/flotation in the diagnosis of canine spirocercosis.

    PubMed

    Christie, J; Schwan, E V; Bodenstein, L L; Sommerville, J E M; van der Merwe, L L

    2011-06-01

    Several faecal examination techniques have shown variable sensitivity in demonstrating Spirocerca lupi (S. lupi) eggs. The objective of this study was to determine which faecal examination technique, including a novel modified centrifugal flotation technique, was most sensitive to diagnose spirocercosis. Ten coproscopic examinations were performed on faeces collected from 33 dogs confirmed endoscopically to have spirocercosis. The tests included a direct faecal examination, a faecal sedimentation/flotation test, 4 direct faecal flotations and 4 modified faecal centrifugal flotations. These latter 2 flotation tests utilised 4 different faecal flotation solutions: NaNO3 (SG 1.22), MgSO4 (SG 1.29), ZnSO4 (SG 1.30) and sugar (SG 1.27). The sensitivity of the tests ranged between 42% and 67%, with the NaNO3 solution showing the highest sensitivity in both the direct and modified-centrifugal flotations. The modified NaNO3 centrifugal method ranked 1st with the highest mean egg count (45.24 +/- 83), and was superior (i.e. higher egg count) and significantly different (P < 0.05) compared with the routine saturated sugar, ZnSO4 and MgSO4 flotation methods. The routine NaNO3 flotation method was also superior and significantly different (P < 0.05) compared with the routine ZnSO4 and MgSO4 flotation methods. Fifteen per cent (n = 5) of dogs had neoplastic oesophageal nodules and a further 18% (n = 6) had both neoplastic and non-neoplastic nodules. S. lupi eggs were demonstrated in 40% of dogs with neoplastic nodules only and 72.9% of the dogs with non-neoplastic nodules. The mean egg count in the non-neoplastic group (61) was statistically greater (P = 0.02) than that of the neoplastic group (1). The results show that faecal examination using a NaNO3 solution is the most sensitive in the diagnosis of spirocercosis. The modified centrifugal flotation faecal method using this solution has the highest egg count. The study also found that dogs with neoplastic nodules shed significantly fewer eggs than dogs with non-neoplastic nodules.

  14. Note: Fully integrated active quenching circuit achieving 100 MHz count rate with custom technology single photon avalanche diodes.

    PubMed

    Acconcia, G; Labanca, I; Rech, I; Gulinatti, A; Ghioni, M

    2017-02-01

    The minimization of Single Photon Avalanche Diodes (SPADs) dead time is a key factor to speed up photon counting and timing measurements. We present a fully integrated Active Quenching Circuit (AQC) able to provide a count rate as high as 100 MHz with custom technology SPAD detectors. The AQC can also operate the new red enhanced SPAD and provide the timing information with a timing jitter Full Width at Half Maximum (FWHM) as low as 160 ps.

  15. 42 CFR 435.603 - Application of modified adjusted gross income (MAGI).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... household. In the case of determining the family size of a pregnant woman, the pregnant woman is counted as... of other individuals who have a pregnant woman in their household, the pregnant woman is counted, at... history of predictable fluctuations in income, or other clear indicia of such future changes in income...

  16. Obtaining Parts

    Science.gov Websites

    The Cosmic Connection Computer Interface For each count, the detector sends out a signal that is room temperature on the upper plot and the cosmic ray count rate per minute on the lower scale. Please contact us for more details on this setup. Sample Data for Cosmic Ray Detector Last modified: April 27

  17. Intestinal parasitic infections in relation to HIV/AIDS status, diarrhea and CD4 T-cell count.

    PubMed

    Assefa, Shimelis; Erko, Berhanu; Medhin, Girmay; Assefa, Zelalem; Shimelis, Techalew

    2009-09-18

    HIV infection has been modifying both the epidemiology and outcome of parasitic infections. Hence, this study was undertaken to determine the prevalence of intestinal parasitic infection among people with and without HIV infection and its association with diarrhea and CD4 T-cell count. A cross-sectional study was conducted at Hawassa Teaching and Referral Hospital focusing on HIV positive individuals, who gave blood for CD4 T-cell count at their first enrollment and clients tested HIV negative from November, 2008 to March, 2009. Data on socio-demographic factors and diarrhea status were obtained by interviewing 378 consecutive participants (214 HIV positive and 164 HIV negative). Stool samples were collected from all study subjects and examined for parasites using direct, formol-ether and modified acid fast stain techniques. The prevalence of any intestinal parasitic infection was significantly higher among HIV positive participants. Specifically, rate of infection with Cryptosporidium, I. belli, and S. stercoralis were higher, particularly in those with CD4 count less than 200 cells/microL. Diarrhea was more frequent also at the same lower CD4 T-cell counts. Immunodeficiency increased the risk of having opportunistic parasites and diarrhea. Therefore; raising patient immune status and screening at least for those treatable parasites is important.

  18. Calibration of a Modified Andersen Bacterial Aerosol Sampler

    PubMed Central

    May, K. R.

    1964-01-01

    A study of the flow regime in the commercial Andersen sampler revealed defects in the sampling of the larger airborne particles. Satisfactory sampling was obtained by redesigning the hole pattern of the top stages and adding one more stage to extend the range of the instrument. A new, rational hole pattern is suggested for the lower stages. With both patterns a special colony-counting mask can be used to facilitate the assay. A calibration of the modified system is presented which enables particle size distribution curves to be drawn from the colony counts. Images FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 FIG. 8 PMID:14106938

  19. A PFM-based MWIR DROIC employing off-pixel fine conversion of photocharge to digital using integrated column ADCs

    NASA Astrophysics Data System (ADS)

    Abbasi, S.; Galioglu, A.; Shafique, A.; Ceylan, O.; Yazici, M.; Gurbuz, Y.

    2017-02-01

    A 32x32 prototype of a digital readout IC (DROIC) for medium-wave infrared focal plane arrays (MWIR IR-FPAs) is presented. The DROIC employs in-pixel photocurrent to digital conversion based on a pulse frequency modulation (PFM) loop and boasts a novel feature of off-pixel residue conversion using 10-bit column SAR ADCs. The remaining charge at the end of integration in typical PFM based digital pixel sensors is usually wasted. Previous works employing in-pixel extended counting methods make use of extra memory and counters to convert this left-over charge to digital, thereby performing fine conversion of the incident photocurrent. This results in a low quantization noise and hence keeps the readout noise low. However, focal plane arrays (FPAs) with small pixel pitch are constrained in pixel area, which makes it difficult to benefit from in-pixel extended counting circuitry. Thus, in this work, a novel approach to measure the residue outside the pixel using column -parallel SAR ADCs has been proposed. Moreover, a modified version of the conventional PFM based pixel has been designed to help hold the residue charge and buffer it to the column ADC. In addition to the 2D array of pixels, the prototype consists of 32 SAR ADCs, a timing controller block and a memory block to buffer the residue data coming out of the ADCs. The prototype has been designed and fabricated in 90nm CMOS.

  20. Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: A feasibility study

    PubMed Central

    Ding, Huanjun; Molloi, Sabee

    2012-01-01

    Purpose A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. Methods A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio (SNR) of the dual energy image with respect to the square root of mean glandular dose (MGD), was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. Results For an average sized breast of 4.5 cm thick, the FOM was maximized with a tube voltage of 46kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (~ 32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. Conclusions The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique. PMID:22771941

  1. Assessing avian richness in remnant wetlands: Towards an improved methodology

    USGS Publications Warehouse

    Krzys, Greg; Waite, Thomas A.; Stapanian, Martin; Vucetich, John A.

    2002-01-01

    Because the North American Breeding Bird Survey provides inadequate coverage of wetland habitat, the Wetland Breeding Bird Survey was recently established in Ohio, USA. This program relies on volunteers to conduct 3 counts at each monitored wetland. Currently, all counts are conducted during the morning. Under the premise that volunteer participation could be increased by allowing evening counts, we evaluated the potential for modifying the methodology. We evaluated the sampling efficiency of all 3-count combinations of morning and evening counts using data collected at 14 wetlands. Estimates of overall species richness decreased with increasing numbers of evening counts. However, this pattern did not hold when analyses were restricted to wetland-dependent species or those of conservation concern. Our findings suggest that it would be reasonable to permit evening counts, particularly if the data are to be used to monitor wetland dependent species and those of concern.

  2. 42 CFR 435.603 - Application of modified adjusted gross income (MAGI).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... size of a pregnant woman, the pregnant woman is counted as herself plus the number of children she is... woman in their household, the pregnant woman is counted, at State option, as either 1 or 2 person(s) or... signed contract for employment, a clear history of predictable fluctuations in income, or other clear...

  3. Amplitude distributions of dark counts and photon counts in NbN superconducting single-photon detectors integrated with the HEMT readout

    NASA Astrophysics Data System (ADS)

    Kitaygorsky, J.; Słysz, W.; Shouten, R.; Dorenbos, S.; Reiger, E.; Zwiller, V.; Sobolewski, Roman

    2017-01-01

    We present a new operation regime of NbN superconducting single-photon detectors (SSPDs) by integrating them with a low-noise cryogenic high-electron-mobility transistor and a high-load resistor. The integrated sensors are designed to get a better understanding of the origin of dark counts triggered by the detector, as our scheme allows us to distinguish the origin of dark pulses from the actual photon pulses in SSPDs. The presented approach is based on a statistical analysis of amplitude distributions of recorded trains of the SSPD photoresponse transients. It also enables to obtain information on energy of the incident photons, as well as demonstrates some photon-number-resolving capability of meander-type SSPDs.

  4. The correlation between indoor and in soil radon concentrations in a desert climate

    NASA Astrophysics Data System (ADS)

    Al-Khateeb, H. M.; Aljarrah, K. M.; Alzoubi, F. Y.; Alqadi, M. K.; Ahmad, A. A.

    2017-01-01

    This study examines the levels and the correlation between indoor and in soil radon concentration in a desert climate. The measurements are carried out, in Jordan desert in AlMafraq district, using the passive integrated technique. An intelligent automated tracks counting system, modified recently by our group, is used to estimate the overlapping tracks and to decrease the counting percentage error. Results show that radon concentration in soil expands from 4.09 to 11.30 kBq m-3, with an average of 7.53 kBq m-3. Indoor radon concentrations vary from 20.2 Bq m-3 in the AlMafraq city to 46.7 Bq m-3 in Housha village and with an average of 29.6 Bq m-3. All of individual indoor radon concentrations are lower than the limit (100 Bq m-3) recommended by WHO except two dwellings in Housha village which found being higher than this limit. A moderate linear correlation (R2=0.66) was observed between indoor and in soil radon concentrations in the investigated region. Our results showed that an in soil radon measurement can be a satisfactory predictor for indoor radon potential.

  5. Extended range radiation dose-rate monitor

    DOEpatents

    Valentine, Kenneth H.

    1988-01-01

    An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

  6. In vitro adherence of radioactively labeled Escherichia coli in normal and cystitis-prone females

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parsons, C.L.; Anwar, H.; Stauffer, C.

    Numerous investigators report data obtained using an in vitro quantitative assay for measuring bacterial adherence to epithelial cells. In the modified assay described here, we eliminated the need for visual counting of bacteria by incorporating the use of radioactively labeled Escherichia coli. This allowed quantitation of bacterial adherence to as many as 50,000 vaginal cells, whereas the visual counting system limits the determination to perhaps 50 cells. Using the modified method, we found no statistically significant differences among values for adherence of E. coli type 04 to the vaginal cells of control and cystitis-prone women at either pH 6.4 ormore » 4.0.« less

  7. Nutsedge Counts Predict Meloidogyne incognita Juvenile Counts in an Integrated Management System.

    PubMed

    Ou, Zhining; Murray, Leigh; Thomas, Stephen H; Schroeder, Jill; Libbin, James

    2008-06-01

    The southern root-knot nematode (Meloidogyne incognita), yellow nutsedge (Cyperus esculentus) and purple nutsedge (Cyperus rotundus) are important pests in crops grown in the southern US. Management of the individual pests rather than the pest complex is often unsuccessful due to mutually beneficial pest interactions. In an integrated pest management scheme using alfalfa to suppress nutsedges and M. incognita, we evaluated quadratic polynomial regression models for prediction of the number of M. incognita J2 in soil samples as a function of yellow and purple nutsedge plant counts, squares of nutsedge counts and the cross-product between nutsedge counts . In May 2005, purple nutsedge plant count was a significant predictor of M. incognita count. In July and September 2005, counts of both nutsedges and the cross-product were significant predictors. In 2006, the second year of the alfalfa rotation, counts of all three species were reduced. As a likely consequence, the predictive relationship between nutsedges and M. incognita was not significant for May and July. In September 2006, purple nutsedge was a significant predictor of M. incognita. These results lead us to conclude that nutsedge plant counts in a field infested with the M. incognita-nutsedge pest complex can be used as a visual predictor of M. incognita J2 populations, unless the numbers of nutsedge plants and M. incognita are all very low.

  8. Nutsedge Counts Predict Meloidogyne incognita Juvenile Counts in an Integrated Management System

    PubMed Central

    Ou, Zhining; Murray, Leigh; Thomas, Stephen H.; Schroeder, Jill; Libbin, James

    2008-01-01

    The southern root-knot nematode (Meloidogyne incognita), yellow nutsedge (Cyperus esculentus) and purple nutsedge (Cyperus rotundus) are important pests in crops grown in the southern US. Management of the individual pests rather than the pest complex is often unsuccessful due to mutually beneficial pest interactions. In an integrated pest management scheme using alfalfa to suppress nutsedges and M. incognita, we evaluated quadratic polynomial regression models for prediction of the number of M. incognita J2 in soil samples as a function of yellow and purple nutsedge plant counts, squares of nutsedge counts and the cross-product between nutsedge counts . In May 2005, purple nutsedge plant count was a significant predictor of M. incognita count. In July and September 2005, counts of both nutsedges and the cross-product were significant predictors. In 2006, the second year of the alfalfa rotation, counts of all three species were reduced. As a likely consequence, the predictive relationship between nutsedges and M. incognita was not significant for May and July. In September 2006, purple nutsedge was a significant predictor of M. incognita. These results lead us to conclude that nutsedge plant counts in a field infested with the M. incognita-nutsedge pest complex can be used as a visual predictor of M. incognita J2 populations, unless the numbers of nutsedge plants and M. incognita are all very low. PMID:19259526

  9. Low photon-count tip-tilt sensor

    NASA Astrophysics Data System (ADS)

    Saathof, Rudolf; Schitter, Georg

    2016-07-01

    Due to the low photon-count of dark areas of the universe, signal strength of tip-tilt sensor is low, limiting sky-coverage of reliable tip-tilt measurements. This paper presents the low photon-count tip-tilt (LPC-TT) sensor, which potentially achieves improved signal strength. Its optical design spatially samples and integrates the scene. This increases the probability that several individual sources coincide on a detector segment. Laboratory experiments show feasibility of spatial sampling and integration and the ability to measure tilt angles. By simulation an improvement of the SNR of 10 dB compared to conventional tip-tilt sensors is shown.

  10. Evaluation of potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar for enumeration of Campylobacter in chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-05-01

    Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess. © 2014 Institute of Food Technologists®

  11. High event rate ROICs (HEROICs) for astronomical UV photon counting detectors

    NASA Astrophysics Data System (ADS)

    Harwit, Alex; France, Kevin; Argabright, Vic; Franka, Steve; Freymiller, Ed; Ebbets, Dennis

    2014-07-01

    The next generation of astronomical photocathode / microchannel plate based UV photon counting detectors will overcome existing count rate limitations by replacing the anode arrays and external cabled electronics with anode arrays integrated into imaging Read Out Integrated Circuits (ROICs). We have fabricated a High Event Rate ROIC (HEROIC) consisting of a 32 by 32 array of 55 μm square pixels on a 60 μm pitch. The pixel sensitivity (threshold) has been designed to be globally programmable between 1 × 103 and 1 × 106 electrons. To achieve the sensitivity of 1 × 103 electrons, parasitic capacitances had to be minimized and this was achieved by fabricating the ROIC in a 65 nm CMOS process. The ROIC has been designed to support pixel counts up to 4096 events per integration period at rates up to 1 MHz per pixel. Integration time periods can be controlled via an external signal with a time resolution of less than 1 microsecond enabling temporally resolved imaging and spectroscopy of astronomical sources. An electrical injection port is provided to verify functionality and performance of each ROIC prior to vacuum integration with a photocathode and microchannel plate amplifier. Test results on the first ROICs using the electrical injection port demonstrate sensitivities between 3 × 103 and 4 × 105 electrons are achieved. A number of fixes are identified for a re-spin of this ROIC.

  12. Single Photon Counting Performance and Noise Analysis of CMOS SPAD-Based Image Sensors.

    PubMed

    Dutton, Neale A W; Gyongy, Istvan; Parmesan, Luca; Henderson, Robert K

    2016-07-20

    SPAD-based solid state CMOS image sensors utilising analogue integrators have attained deep sub-electron read noise (DSERN) permitting single photon counting (SPC) imaging. A new method is proposed to determine the read noise in DSERN image sensors by evaluating the peak separation and width (PSW) of single photon peaks in a photon counting histogram (PCH). The technique is used to identify and analyse cumulative noise in analogue integrating SPC SPAD-based pixels. The DSERN of our SPAD image sensor is exploited to confirm recent multi-photon threshold quanta image sensor (QIS) theory. Finally, various single and multiple photon spatio-temporal oversampling techniques are reviewed.

  13. Two-nucleon S10 amplitude zero in chiral effective field theory

    NASA Astrophysics Data System (ADS)

    Sánchez, M. Sánchez; Yang, C.-J.; Long, Bingwei; van Kolck, U.

    2018-02-01

    We present a new rearrangement of short-range interactions in the S10 nucleon-nucleon channel within chiral effective field theory. This is intended to address the slow convergence of Weinberg's scheme, which we attribute to its failure to reproduce the amplitude zero (scattering momentum ≃340 MeV) at leading order. After the power counting scheme is modified to accommodate the zero at leading order, it includes subleading corrections perturbatively in a way that is consistent with renormalization-group invariance. Systematic improvement is shown at next-to-leading order, and we obtain results that fit empirical phase shifts remarkably well all the way up to the pion-production threshold. An approach in which pions have been integrated out is included, which allows us to derive analytic results that also fit phenomenology surprisingly well.

  14. Swarm Observations: Implementing Integration Theory to Understand an Opponent Swarm

    DTIC Science & Technology

    2012-09-01

    80 Figure 14 Box counts and local dimension plots for the “Rally” scenario. .....................81 Figure...88 Figure 21 Spatial entropy over time for the “Avoid” scenario.........................................89 Figure 22 Box counts and local...96 Figure 27 Spatial entropy over time for the “Rally-integration” scenario. ......................97 Figure 28 Box counts and

  15. Resolution of Dialyzer Membrane-Associated Thrombocytopenia with Use of Cellulose Triacetate Membrane: A Case Report

    PubMed Central

    Olafiranye, Feyisayo; Kyaw, Win; Olafiranye, Oladipupo

    2011-01-01

    Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility between synthetic membrane and modified cellulose membrane. Herein, we report a case of a patient on hemodialysis who developed dialyzer-membrane-related thrombocytopenia with use of synthetic membrane (F200NR polysulfone). The diagnosis of dialyzer membrane-associated thrombocytopenia was suspected by the trend of platelet count before and after dialysis, and the absence of other possible causes of thrombocytopenia. We observed significant improvement in platelet count when the membrane was changed to modified cellulose membrane (cellulose triacetate). In patients at high risk for thrombocytopenia, the modified cellulose membrane could be a better alternative to the standard synthetic membranes during hemodialysis. PMID:21547252

  16. Cold plasma: A new technology to modify wheat flour functionality

    PubMed Central

    Bahrami, Niloufar; Bayliss, Danny; Chope, Gemma; Penson, Simon; Perehinec, Tania; Fisk, Ian D.

    2016-01-01

    Atmospheric pressure cold plasma has the potential to modify biological chemistry and modulate physical surface properties. Wheat flour was treated by low levels of cold plasma (air, 15 V and 20 V) for 60 or 120 s. There was no change in the total aerobic bacterial count or total mould count as a result of treatment. Treatment did not impact the concentration of total non-starch lipids, or non-polar and glycolipids. However, treatment did reduce total free fatty acids and phospholipids and was dose dependent. Oxidation markers (hydroperoxide value and head space n-hexanal) increased with treatment time and voltage, which confirmed the acceleration of lipid oxidation. Total proteins were not significantly influenced by treatment although there was a trend towards higher molecular weight fractions which indicated protein oxidation and treated flour did produce a stronger dough. This study confirms the potential of cold plasma as a tool to modify flour functionality. PMID:26920291

  17. Influence of resin-modified glass ionomer and topical fluoride on levels of Streptococcus mutans in saliva and biofilm adjacent to metallic brackets

    PubMed Central

    ANDRUCIOLI, Marcela Cristina Damião; FARIA, Gisele; NELSON-FILHO, Paulo; ROMANO, Fábio Lourenço; MATSUMOTO, Mírian Aiko Nakane

    2017-01-01

    Abstract Decalcification of enamel during fixed orthodontic appliance treatment remains a problem. White spot lesions are observed in nearly 50% of patients undergoing orthodontic treatment. The use of fluoride-containing orthodontic materials has shown inconclusive results on their ability to reduce decalcification. The aims of this investigation were to compare the levels of Streptococcus mutans (SM) in saliva and biofilm adjacent to orthodontic brackets retained with a resin-modified glass ionomer cement (RMGIC) (Fuji ORTHO LC) and a light cured composite resin (Transbond XT), and to analyze the influence of topical application of the 1.23% acidulated phosphate fluoride (APF) on SM counts. In a parallel study design, two groups (n=14/15) were used with random allocation and high salivary SM counts before treatment. Biofilm was collected from areas adjacent to the brackets on teeth 13, 22, 33, and 41. Both saliva and biofilm were collected on the 7th, 21st, 35th, and 49th days after appliance placement. Topical fluoride application was carried out on the 35th day. Bonding with RMGIC did not alter SM counts in saliva or biofilm adjacent to the brackets. On the other hand, the biofilm adjacent to brackets retained with composite resin showed a significant increase in SM counts along the trial period. Topical application of 1.23% APF did not reduce salivary or biofilm SM counts regardless of the bonding material. In conclusion, fluoride topical application did not show efficacy in reducing SM. The use of RMGIC as bonding materials allowed a better control of SM cfu counts in dental biofilm hindering the significant increase of these microorganisms along the trial period, which was observed in the biofilm adjacent to the composite material. PMID:28403360

  18. Influence of resin-modified glass ionomer and topical fluoride on levels of Streptococcus mutans in saliva and biofilm adjacent to metallic brackets.

    PubMed

    Andrucioli, Marcela Cristina Damião; Faria, Gisele; Nelson-Filho, Paulo; Romano, Fábio Lourenço; Matsumoto, Mírian Aiko Nakane

    2017-01-01

    Decalcification of enamel during fixed orthodontic appliance treatment remains a problem. White spot lesions are observed in nearly 50% of patients undergoing orthodontic treatment. The use of fluoride-containing orthodontic materials has shown inconclusive results on their ability to reduce decalcification. The aims of this investigation were to compare the levels of Streptococcus mutans (SM) in saliva and biofilm adjacent to orthodontic brackets retained with a resin-modified glass ionomer cement (RMGIC) (Fuji ORTHO LC) and a light cured composite resin (Transbond XT), and to analyze the influence of topical application of the 1.23% acidulated phosphate fluoride (APF) on SM counts. In a parallel study design, two groups (n=14/15) were used with random allocation and high salivary SM counts before treatment. Biofilm was collected from areas adjacent to the brackets on teeth 13, 22, 33, and 41. Both saliva and biofilm were collected on the 7th, 21st, 35th, and 49th days after appliance placement. Topical fluoride application was carried out on the 35th day. Bonding with RMGIC did not alter SM counts in saliva or biofilm adjacent to the brackets. On the other hand, the biofilm adjacent to brackets retained with composite resin showed a significant increase in SM counts along the trial period. Topical application of 1.23% APF did not reduce salivary or biofilm SM counts regardless of the bonding material. In conclusion, fluoride topical application did not show efficacy in reducing SM. The use of RMGIC as bonding materials allowed a better control of SM cfu counts in dental biofilm hindering the significant increase of these microorganisms along the trial period, which was observed in the biofilm adjacent to the composite material.

  19. A qualitative evaluation of a physician-delivered pedometer-based step count prescription strategy with insight from participants and treating physicians.

    PubMed

    Cooke, Alexandra B; Pace, Romina; Chan, Deborah; Rosenberg, Ellen; Dasgupta, Kaberi; Daskalopoulou, Stella S

    2018-05-01

    The integration of pedometers into clinical practice has the potential to enhance physical activity levels in patients with chronic disease. Our SMARTER randomized controlled trial demonstrated that a physician-delivered step count prescription strategy has measurable effects on daily steps, glycemic control, and insulin resistance in patients with type 2 diabetes and/or hypertension. In this study, we aimed to understand perceived barriers and facilitators influencing successful uptake and sustainability of the strategy, from patient and physician perspectives. Qualitative in-depth interviews were conducted in a purposive sample of physicians (n = 10) and participants (n = 20), including successful and less successful cases in terms of pedometer-assessed step count improvements. Themes that achieved saturation in either group through thematic analysis are presented. All participants appreciated the pedometer-based monitoring combined with step count prescriptions. Accountability to physicians and support offered by the trial coordinator influenced participant motivation. Those who increased step counts adopted strategies to integrate more steps into their routines and were able to overcome weather-related barriers by finding indoor alternative options to outdoor steps. Those who decreased step counts reported difficulty in overcoming weather-related challenges, health limitations and work constraints. Physicians indicated the strategy provided a framework for discussing physical activity and motivating patients, but emphasized the need for support from allied professionals to help deliver the strategy in busy clinical settings. A physician-delivered step count prescription strategy was feasibly integrated into clinical practice and successful in engaging most patients; however, continual support is needed for maximal engagement and sustained use. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Waveguide integrated superconducting single-photon detectors with high internal quantum efficiency at telecom wavelengths

    PubMed Central

    Kahl, Oliver; Ferrari, Simone; Kovalyuk, Vadim; Goltsman, Gregory N.; Korneev, Alexander; Pernice, Wolfram H. P.

    2015-01-01

    Superconducting nanowire single-photon detectors (SNSPDs) provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, compatibility with an integrated optical platform is a crucial requirement for applications in emerging quantum photonic technologies. Here we present SNSPDs embedded in nanophotonic integrated circuits which achieve internal quantum efficiencies close to unity at 1550 nm wavelength. This allows for the SNSPDs to be operated at bias currents far below the critical current where unwanted dark count events reach milli-Hz levels while on-chip detection efficiencies above 70% are maintained. The measured dark count rates correspond to noise-equivalent powers in the 10−19 W/Hz−1/2 range and the timing jitter is as low as 35 ps. Our detectors are fully scalable and interface directly with waveguide-based optical platforms. PMID:26061283

  1. Waveguide integrated superconducting single-photon detectors with high internal quantum efficiency at telecom wavelengths.

    PubMed

    Kahl, Oliver; Ferrari, Simone; Kovalyuk, Vadim; Goltsman, Gregory N; Korneev, Alexander; Pernice, Wolfram H P

    2015-06-10

    Superconducting nanowire single-photon detectors (SNSPDs) provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, compatibility with an integrated optical platform is a crucial requirement for applications in emerging quantum photonic technologies. Here we present SNSPDs embedded in nanophotonic integrated circuits which achieve internal quantum efficiencies close to unity at 1550 nm wavelength. This allows for the SNSPDs to be operated at bias currents far below the critical current where unwanted dark count events reach milli-Hz levels while on-chip detection efficiencies above 70% are maintained. The measured dark count rates correspond to noise-equivalent powers in the 10(-19) W/Hz(-1/2) range and the timing jitter is as low as 35 ps. Our detectors are fully scalable and interface directly with waveguide-based optical platforms.

  2. A proposal of a local modified QCD

    NASA Astrophysics Data System (ADS)

    Cabo Montes de Oca, A.

    2012-06-01

    A local and renormalizable version of a modified PQCD introduced in previous works is presented. The construction indicates that it could be equivalent to massless QCD. The case in which only quark condensate effects are retained is discussed in more detail. Then, the appearing auxiliary fermion fields can be integrated, leading to a theory with the action of massless QCD, to which one local and gauge invariant Lagrangian term for each quark flavour is added. Those action terms are defined by two gluon and two quark fields, in a form curiously not harming power counting renormalizability. The gluon self-energy is evaluated in second order in the gauge coupling and all orders in the new quark couplings, and the result became transversal as required by the gauge invariance. The vacuum energy was also calculated in the two-loop approximation and became gauge parameter independent. The possibilities that higher-loop contributions to the vacuum energy allow the generation of a quark mass hierarchy as a flavour symmetry-breaking effect are commented. The decision on this issue needs a further evaluation of more than two-loop contributions, in which more than one type of quark loops start appearing, possibly leading to interference effects in the vacuum energy.

  3. Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

    NASA Technical Reports Server (NTRS)

    Burton, William D., Jr.; Schultz, J. Albert; Vaughn, Valentine; McCully, Michael; Ulrich, Steven; Egan, Thomas F.

    2006-01-01

    A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

  4. The effect of different gas permeability of packaging on physicochemical and microbiological parameters of pork loin storage under high O2 modified atmosphere packaging conditions.

    PubMed

    Marcinkowska-Lesiak, Monika; Poławska, Ewa; Wierzbicka, Agnieszka

    2017-03-01

    The aim of this study was to determine the influence of different packaging materials on meat quality during cold storage. Therefore pork loins (m. longissimus thoracis et lumborum) obtained from crossbred pigs (Polish Landrance x Duroc, n = 6) were stored at 2 ℃ in modified atmosphere packs (80% O 2 , 20% CO 2 ) in four types of trays, which differ in gas permeability. Physicochemical (headspace gas composition, pH, colour, drip loss, cooking loss, shear force, the basic composition and fatty acid profile) and microbiological ( Salmonella spp., Escherichia coli, Enterobacteriaceae, total aerobic plates count, total psychrotrophic bacteria count, the number of lactic acid bacteria, Pseudomonas spp., the general amount of yeast and mold) parameters were monitored for up to 12 days. At the end of the storage period no differences in most physicochemical properties of pork loin due to type of packaging were found, however trays with high gas permeability had the greatest impact on total aerobic plates count and Pseudomonas spp. growth.

  5. 7 CFR 932.149 - Modified minimum quality requirements for specified styles of canned olives of the ripe type.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Fragments (Pitted Style Only) Not more than 1.3% average by count Major Stems Not more than 3 HEVM Not more... per 300 grams Major Stems Not more than 3 HEVM Not more than 2 units per sample Broken Pieces and End... Fragments Average of not more than 1 by count per 300 grams Major Stems Not more than 3 HEVM Not more than 2...

  6. 7 CFR 932.149 - Modified minimum quality requirements for specified styles of canned olives of the ripe type.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Fragments (Pitted Style Only) Not more than 1.3% average by count Major Stems Not more than 3 HEVM Not more... per 300 grams Major Stems Not more than 3 HEVM Not more than 2 units per sample Broken Pieces and End... Fragments Average of not more than 1 by count per 300 grams Major Stems Not more than 3 HEVM Not more than 2...

  7. 7 CFR 932.149 - Modified minimum quality requirements for specified styles of canned olives of the ripe type.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Fragments (Pitted Style Only) Not more than 1.3% average by count Major Stems Not more than 3 HEVM Not more... per 300 grams Major Stems Not more than 3 HEVM Not more than 2 units per sample Broken Pieces and End... Fragments Average of not more than 1 by count per 300 grams Major Stems Not more than 3 HEVM Not more than 2...

  8. 7 CFR 932.149 - Modified minimum quality requirements for specified styles of canned olives of the ripe type.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Fragments (Pitted Style Only) Not more than 1.3% average by count Major Stems Not more than 3 HEVM Not more... per 300 grams Major Stems Not more than 3 HEVM Not more than 2 units per sample Broken Pieces and End... Fragments Average of not more than 1 by count per 300 grams Major Stems Not more than 3 HEVM Not more than 2...

  9. 7 CFR 932.149 - Modified minimum quality requirements for specified styles of canned olives of the ripe type.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Fragments (Pitted Style Only) Not more than 1.3% average by count Major Stems Not more than 3 HEVM Not more... per 300 grams Major Stems Not more than 3 HEVM Not more than 2 units per sample Broken Pieces and End... Fragments Average of not more than 1 by count per 300 grams Major Stems Not more than 3 HEVM Not more than 2...

  10. Single Photon Counting Performance and Noise Analysis of CMOS SPAD-Based Image Sensors

    PubMed Central

    Dutton, Neale A. W.; Gyongy, Istvan; Parmesan, Luca; Henderson, Robert K.

    2016-01-01

    SPAD-based solid state CMOS image sensors utilising analogue integrators have attained deep sub-electron read noise (DSERN) permitting single photon counting (SPC) imaging. A new method is proposed to determine the read noise in DSERN image sensors by evaluating the peak separation and width (PSW) of single photon peaks in a photon counting histogram (PCH). The technique is used to identify and analyse cumulative noise in analogue integrating SPC SPAD-based pixels. The DSERN of our SPAD image sensor is exploited to confirm recent multi-photon threshold quanta image sensor (QIS) theory. Finally, various single and multiple photon spatio-temporal oversampling techniques are reviewed. PMID:27447643

  11. Gravity at the horizon: on relativistic effects, CMB-LSS correlations and ultra-large scales in Horndeski's theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renk, Janina; Zumalacárregui, Miguel; Montanari, Francesco, E-mail: renk@thphys.uni-heidelberg.de, E-mail: miguel.zumalacarregui@nordita.org, E-mail: francesco.montanari@helsinki.fi

    2016-07-01

    We address the impact of consistent modifications of gravity on the largest observable scales, focusing on relativistic effects in galaxy number counts and the cross-correlation between the matter large scale structure (LSS) distribution and the cosmic microwave background (CMB). Our analysis applies to a very broad class of general scalar-tensor theories encoded in the Horndeski Lagrangian and is fully consistent on linear scales, retaining the full dynamics of the scalar field and not assuming quasi-static evolution. As particular examples we consider self-accelerating Covariant Galileons, Brans-Dicke theory and parameterizations based on the effective field theory of dark energy, using the himore » class code to address the impact of these models on relativistic corrections to LSS observables. We find that especially effects which involve integrals along the line of sight (lensing convergence, time delay and the integrated Sachs-Wolfe effect—ISW) can be considerably modified, and even lead to O(1000%) deviations from General Relativity in the case of the ISW effect for Galileon models, for which standard probes such as the growth function only vary by O(10%). These effects become dominant when correlating galaxy number counts at different redshifts and can lead to ∼ 50% deviations in the total signal that might be observable by future LSS surveys. Because of their integrated nature, these deep-redshift cross-correlations are sensitive to modifications of gravity even when probing eras much before dark energy domination. We further isolate the ISW effect using the cross-correlation between LSS and CMB temperature anisotropies and use current data to further constrain Horndeski models. Forthcoming large-volume galaxy surveys using multiple-tracers will search for all these effects, opening a new window to probe gravity and cosmic acceleration at the largest scales available in our universe.« less

  12. On the influence of noise correlations in measurement data on basis image noise in dual-energylike x-ray imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roessl, Ewald; Ziegler, Andy; Proksa, Roland

    2007-03-15

    In conventional dual-energy systems, two transmission measurements with distinct spectral characteristics are performed. These measurements are used to obtain the line integrals of two basis material densities. Usually, the measurement process is such that the two measured signals can be treated as independent and therefore uncorrelated. Recently, however, a readout system for x-ray detectors has been introduced for which this is no longer the case. The readout electronics is designed to obtain simultaneous measurements of the total number of photons N and the total energy E they deposit in the sensor material. Practically, this is realized by a signal replicationmore » and separate counting and integrating processing units. Since the quantities N and E are (electronically) derived from one and the same physical sensor signal, they are statistically correlated. Nevertheless, the pair N and E can be used to perform a dual-energy processing following the well-known approach by Alvarez and Macovski. Formally, this means that N is to be identified with the first dual-energy measurement M{sub 1} and E with the second measurement M{sub 2}. In the presence of input correlations between M{sub 1}=N and M{sub 2}=E, however, the corresponding analytic expressions for the basis image noise have to be modified. The main observation made in this paper is that for positively correlated data, as is the case for the simultaneous counting and integrating device mentioned above, the basis image noise is suppressed through the influence of the covariance between the two signals. We extend the previously published relations for the basis image noise to the case where the original measurements are not independent and illustrate the importance of the input correlations by comparing dual-energy basis image noise resulting from the device mentioned above and a device measuring the photon numbers and the deposited energies consecutively.« less

  13. Monolithically compatible impedance measurement

    DOEpatents

    Ericson, Milton Nance; Holcomb, David Eugene

    2002-01-01

    A monolithic sensor includes a reference channel and at least one sensing channel. Each sensing channel has an oscillator and a counter driven by the oscillator. The reference channel and the at least one sensing channel being formed integrally with a substrate and intimately nested with one another on the substrate. Thus, the oscillator and the counter have matched component values and temperature coefficients. A frequency determining component of the sensing oscillator is formed integrally with the substrate and has an impedance parameter which varies with an environmental parameter to be measured by the sensor. A gating control is responsive to an output signal generated by the reference channel, for terminating counting in the at least one sensing channel at an output count, whereby the output count is indicative of the environmental parameter, and successive ones of the output counts are indicative of changes in the environmental parameter.

  14. Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate

    PubMed Central

    Schuck, Carsten; Pernice, Wolfram H. P.; Tang, Hong X.

    2013-01-01

    Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10−20 W/Hz1/2 level. PMID:23714696

  15. Controlling Legionella and Pseudomonas aeruginosa re-growth in therapeutic spas: implementation of physical disinfection treatments, including UV/ultrafiltration, in a respiratory hydrotherapy system.

    PubMed

    Leoni, E; Sanna, T; Zanetti, F; Dallolio, L

    2015-12-01

    The study aimed to assess the efficacy of an integrated water safety plan (WSP) in controlling Legionella re-growth in a respiratory hydrotherapy system located in a spa centre, supplied with sulphurous water, which was initially colonized by Legionella pneumophila. Heterotrophic plate counts, Pseudomonas aeruginosa, Legionella spp. were detected in water samples taken 6-monthly from the hydrotherapy equipment (main circuit, entry to benches, final outlets). On the basis of the results obtained by the continuous monitoring and the changes in conditions, the original WSP, including physical treatments of water and waterlines, environmental surveillance and microbiological monitoring, was integrated introducing a UV/ultrafiltration system. The integrated treatment applied to the sulphurous water (microfiltration/UV irradiation/ultrafiltration), waterlines (superheated stream) and distal outlets (descaling/disinfection of nebulizers and nasal irrigators), ensured the removal of Legionella spp. and P. aeruginosa and a satisfactory microbiological quality over time. The environmental surveillance was successful in evaluating the hazard and identifying the most suitable preventive strategies to avoid Legionella re-growth. Ultrafiltration is a technology to take into account in the control of microbial contamination of therapeutic spas, since it does not modify the chemical composition of the water, thus allowing it to retain its therapeutic properties.

  16. Reliability and validity of an audio signal modified shuttle walk test.

    PubMed

    Singla, Rupak; Rai, Richa; Faye, Abhishek Anil; Jain, Anil Kumar; Chowdhury, Ranadip; Bandyopadhyay, Debdutta

    2017-01-01

    The audio signal in the conventionally accepted protocol of shuttle walk test (SWT) is not well-understood by the patients and modification of the audio signal may improve the performance of the test. The aim of this study is to study the validity and reliability of an audio signal modified SWT, called the Singla-Richa modified SWT (SWTSR), in healthy normal adults. In SWTSR, the audio signal was modified with the addition of reverse counting to it. A total of 54 healthy normal adults underwent conventional SWT (CSWT) at one instance and two times SWTSRon the same day. The validity was assessed by comparing outcomes of the SWTSRto outcomes of CSWT using the Pearson correlation coefficient and Bland-Altman plot. Test-retest reliability of SWTSRwas assessed using the intraclass correlation coefficient (ICC). The acceptability of the modified test in comparison to the conventional test was assessed using Likert scale. The distance walked (mean ± standard deviation) in the CSWT and SWTSRtest was 853.33 ± 217.33 m and 857.22 ± 219.56 m, respectively (Pearson correlation coefficient - 0.98; P < 0.001) indicating SWTSRto be a valid test. The SWTSRwas found to be a reliable test with ICC of 0.98 (95% confidence interval: 0.97-0.99). The acceptability of SWTSRwas significantly higher than CSWT. The SWTSRwith modified audio signal with reverse counting is a reliable as well as a valid test when compared with CSWT in healthy normal adults. It better understood by subjects compared to CSWT.

  17. Testing the Hypothesis of Young Martian Volcanism: Studies of the Tharsis Volcanoes and Adjacent Lava Plains

    NASA Technical Reports Server (NTRS)

    Grier, Jennifer A.

    2005-01-01

    We experienced much success in reaching our stated goals in our original MDAP proposal. Our work made substantial contributions towards an integrated understanding of the counting and calibration of crater data on Mars, and changing nature of the Martian surface influenced by craters, water, and wind, and their general relationship to Martian geothermal history. We accomplished this while being to responsive to the rapid changes in the field brought about by several key NASA missions that returned data during the life of the grant. Our integrated effort included three stages: The first major area of research (Crater Count Research) was conducted by Jennifer Grier (P.I.), Lazslo Keszthelyi (Collaborator), William Hartmann (Collaborator), with assistance from Dan Berman (Graduate student) and concerned the mapping and the collection of crater count data on various Martian terrains. The second major area of study (Absolute Age Calibration) was conducted by William Bottke (Co-I) at SWRI, and concerned constraining the nature of the Moon and Mars impactor populations to create better absolute age calibrations for counted areas. The third major area of study was the integration and leverage of this effort with ongoing related Mars crater work at PSI (Integrated and Continuing Studies - Older Volcanoes), headed by David Crown (PSI Scientist), assisted by Les Bleamaster (PSI Scientist) and Dan Berman (Graduate Student).

  18. Multiple-Event, Single-Photon Counting Imaging Sensor

    NASA Technical Reports Server (NTRS)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  19. Bayesian model selection techniques as decision support for shaping a statistical analysis plan of a clinical trial: An example from a vertigo phase III study with longitudinal count data as primary endpoint

    PubMed Central

    2012-01-01

    Background A statistical analysis plan (SAP) is a critical link between how a clinical trial is conducted and the clinical study report. To secure objective study results, regulatory bodies expect that the SAP will meet requirements in pre-specifying inferential analyses and other important statistical techniques. To write a good SAP for model-based sensitivity and ancillary analyses involves non-trivial decisions on and justification of many aspects of the chosen setting. In particular, trials with longitudinal count data as primary endpoints pose challenges for model choice and model validation. In the random effects setting, frequentist strategies for model assessment and model diagnosis are complex and not easily implemented and have several limitations. Therefore, it is of interest to explore Bayesian alternatives which provide the needed decision support to finalize a SAP. Methods We focus on generalized linear mixed models (GLMMs) for the analysis of longitudinal count data. A series of distributions with over- and under-dispersion is considered. Additionally, the structure of the variance components is modified. We perform a simulation study to investigate the discriminatory power of Bayesian tools for model criticism in different scenarios derived from the model setting. We apply the findings to the data from an open clinical trial on vertigo attacks. These data are seen as pilot data for an ongoing phase III trial. To fit GLMMs we use a novel Bayesian computational approach based on integrated nested Laplace approximations (INLAs). The INLA methodology enables the direct computation of leave-one-out predictive distributions. These distributions are crucial for Bayesian model assessment. We evaluate competing GLMMs for longitudinal count data according to the deviance information criterion (DIC) or probability integral transform (PIT), and by using proper scoring rules (e.g. the logarithmic score). Results The instruments under study provide excellent tools for preparing decisions within the SAP in a transparent way when structuring the primary analysis, sensitivity or ancillary analyses, and specific analyses for secondary endpoints. The mean logarithmic score and DIC discriminate well between different model scenarios. It becomes obvious that the naive choice of a conventional random effects Poisson model is often inappropriate for real-life count data. The findings are used to specify an appropriate mixed model employed in the sensitivity analyses of an ongoing phase III trial. Conclusions The proposed Bayesian methods are not only appealing for inference but notably provide a sophisticated insight into different aspects of model performance, such as forecast verification or calibration checks, and can be applied within the model selection process. The mean of the logarithmic score is a robust tool for model ranking and is not sensitive to sample size. Therefore, these Bayesian model selection techniques offer helpful decision support for shaping sensitivity and ancillary analyses in a statistical analysis plan of a clinical trial with longitudinal count data as the primary endpoint. PMID:22962944

  20. Bayesian model selection techniques as decision support for shaping a statistical analysis plan of a clinical trial: an example from a vertigo phase III study with longitudinal count data as primary endpoint.

    PubMed

    Adrion, Christine; Mansmann, Ulrich

    2012-09-10

    A statistical analysis plan (SAP) is a critical link between how a clinical trial is conducted and the clinical study report. To secure objective study results, regulatory bodies expect that the SAP will meet requirements in pre-specifying inferential analyses and other important statistical techniques. To write a good SAP for model-based sensitivity and ancillary analyses involves non-trivial decisions on and justification of many aspects of the chosen setting. In particular, trials with longitudinal count data as primary endpoints pose challenges for model choice and model validation. In the random effects setting, frequentist strategies for model assessment and model diagnosis are complex and not easily implemented and have several limitations. Therefore, it is of interest to explore Bayesian alternatives which provide the needed decision support to finalize a SAP. We focus on generalized linear mixed models (GLMMs) for the analysis of longitudinal count data. A series of distributions with over- and under-dispersion is considered. Additionally, the structure of the variance components is modified. We perform a simulation study to investigate the discriminatory power of Bayesian tools for model criticism in different scenarios derived from the model setting. We apply the findings to the data from an open clinical trial on vertigo attacks. These data are seen as pilot data for an ongoing phase III trial. To fit GLMMs we use a novel Bayesian computational approach based on integrated nested Laplace approximations (INLAs). The INLA methodology enables the direct computation of leave-one-out predictive distributions. These distributions are crucial for Bayesian model assessment. We evaluate competing GLMMs for longitudinal count data according to the deviance information criterion (DIC) or probability integral transform (PIT), and by using proper scoring rules (e.g. the logarithmic score). The instruments under study provide excellent tools for preparing decisions within the SAP in a transparent way when structuring the primary analysis, sensitivity or ancillary analyses, and specific analyses for secondary endpoints. The mean logarithmic score and DIC discriminate well between different model scenarios. It becomes obvious that the naive choice of a conventional random effects Poisson model is often inappropriate for real-life count data. The findings are used to specify an appropriate mixed model employed in the sensitivity analyses of an ongoing phase III trial. The proposed Bayesian methods are not only appealing for inference but notably provide a sophisticated insight into different aspects of model performance, such as forecast verification or calibration checks, and can be applied within the model selection process. The mean of the logarithmic score is a robust tool for model ranking and is not sensitive to sample size. Therefore, these Bayesian model selection techniques offer helpful decision support for shaping sensitivity and ancillary analyses in a statistical analysis plan of a clinical trial with longitudinal count data as the primary endpoint.

  1. Magnification-temperature correlation: The dark side of integrated Sachs-Wolfe measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LoVerde, Marilena; Hui, Lam; Gaztanaga, Enrique

    2007-02-15

    Integrated Sachs-Wolfe (ISW) measurements, which involve cross-correlating the microwave background anisotropies with the foreground large-scale structure (e.g. traced by galaxies/quasars), have proven to be an interesting probe of dark energy. We show that magnification bias, which is the inevitable modulation of the foreground number counts by gravitational lensing, alters both the scale dependence and amplitude of the observed ISW signal. This is true especially at high redshifts because (1) the intrinsic galaxy-temperature signal diminishes greatly back in the matter-dominated era, (2) the lensing efficiency increases with redshift and (3) the number count slope generally steepens with redshift in a magnitudemore » limited sample. At z > or approx. 2, the magnification-temperature correlation dominates over the intrinsic galaxy-temperature correlation and causes the observed ISW signal to increase with redshift, despite dark energy subdominance--a result of the fact that magnification probes structures all the way from the observer to the sources. Ignoring magnification bias therefore can lead to (significantly) erroneous conclusions about dark energy. While the lensing modulation opens up an interesting high z window for ISW measurements, high redshift measurements are not expected to add much new information to low redshift ones if dark energy is indeed the cosmological constant. This is because lensing introduces significant covariance across redshifts. The most compelling reasons for pursuing high redshift ISW measurements are to look for potential surprises such as early dark energy domination or signatures of modified gravity. We conclude with a discussion of existing measurements, the highest redshift of which is at the margin of being sensitive to the magnification effect. We also develop a formalism which might be of more general interest: to predict biases in estimating parameters when certain physical effects are ignored in interpreting observations.« less

  2. Two-nucleon S 0 1 amplitude zero in chiral effective field theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, M. Sanchez; Yang, C. -J.; Long, Bingwei

    We present a new rearrangement of short-range interactions in the 1S 0 nucleon-nucleon channel within chiral effective field theory. This is intended to address the slow convergence of Weinberg’s scheme, which we attribute to its failure to reproduce the amplitude zero (scattering momentum ≃340 MeV) at leading order. After the power counting scheme is modified to accommodate the zero at leading order, it includes subleading corrections perturbatively in a way that is consistent with renormalization-group invariance. Systematic improvement is shown at next-to-leading order, and we obtain results that fit empirical phase shifts remarkably well all the way up to themore » pion-production threshold. As a result, an approach in which pions have been integrated out is included, which allows us to derive analytic results that also fit phenomenology surprisingly well.« less

  3. Two-nucleon S 0 1 amplitude zero in chiral effective field theory

    DOE PAGES

    Sanchez, M. Sanchez; Yang, C. -J.; Long, Bingwei; ...

    2018-02-05

    We present a new rearrangement of short-range interactions in the 1S 0 nucleon-nucleon channel within chiral effective field theory. This is intended to address the slow convergence of Weinberg’s scheme, which we attribute to its failure to reproduce the amplitude zero (scattering momentum ≃340 MeV) at leading order. After the power counting scheme is modified to accommodate the zero at leading order, it includes subleading corrections perturbatively in a way that is consistent with renormalization-group invariance. Systematic improvement is shown at next-to-leading order, and we obtain results that fit empirical phase shifts remarkably well all the way up to themore » pion-production threshold. As a result, an approach in which pions have been integrated out is included, which allows us to derive analytic results that also fit phenomenology surprisingly well.« less

  4. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timmins, Rachel; Klein, Ran; Petryk, Julia

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress.more » Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.« less

  5. An integrated circuit floating point accumulator

    NASA Technical Reports Server (NTRS)

    Goldsmith, T. C.

    1977-01-01

    Goddard Space Flight Center has developed a large scale integrated circuit (type 623) which can perform pulse counting, storage, floating point compression, and serial transmission, using a single monolithic device. Counts of 27 or 19 bits can be converted to transmitted values of 12 or 8 bits respectively. Use of the 623 has resulted in substantial savaings in weight, volume, and dollar resources on at least 11 scientific instruments to be flown on 4 NASA spacecraft. The design, construction, and application of the 623 are described.

  6. Integrated four-channel all-fiber up-conversion single-photon-detector with adjustable efficiency and dark count.

    PubMed

    Zheng, Ming-Yang; Shentu, Guo-Liang; Ma, Fei; Zhou, Fei; Zhang, Hai-Ting; Dai, Yun-Qi; Xie, Xiuping; Zhang, Qiang; Pan, Jian-Wei

    2016-09-01

    Up-conversion single photon detector (UCSPD) has been widely used in many research fields including quantum key distribution, lidar, optical time domain reflectrometry, and deep space communication. For the first time in laboratory, we have developed an integrated four-channel all-fiber UCSPD which can work in both free-running and gate modes. This compact module can satisfy different experimental demands with adjustable detection efficiency and dark count. We have characterized the key parameters of the UCSPD system.

  7. Unified method to integrate and blend several, potentially related, sources of information for genetic evaluation.

    PubMed

    Vandenplas, Jérémie; Colinet, Frederic G; Gengler, Nicolas

    2014-09-30

    A condition to predict unbiased estimated breeding values by best linear unbiased prediction is to use simultaneously all available data. However, this condition is not often fully met. For example, in dairy cattle, internal (i.e. local) populations lead to evaluations based only on internal records while widely used foreign sires have been selected using internally unavailable external records. In such cases, internal genetic evaluations may be less accurate and biased. Because external records are unavailable, methods were developed to combine external information that summarizes these records, i.e. external estimated breeding values and associated reliabilities, with internal records to improve accuracy of internal genetic evaluations. Two issues of these methods concern double-counting of contributions due to relationships and due to records. These issues could be worse if external information came from several evaluations, at least partially based on the same records, and combined into a single internal evaluation. Based on a Bayesian approach, the aim of this research was to develop a unified method to integrate and blend simultaneously several sources of information into an internal genetic evaluation by avoiding double-counting of contributions due to relationships and due to records. This research resulted in equations that integrate and blend simultaneously several sources of information and avoid double-counting of contributions due to relationships and due to records. The performance of the developed equations was evaluated using simulated and real datasets. The results showed that the developed equations integrated and blended several sources of information well into a genetic evaluation. The developed equations also avoided double-counting of contributions due to relationships and due to records. Furthermore, because all available external sources of information were correctly propagated, relatives of external animals benefited from the integrated information and, therefore, more reliable estimated breeding values were obtained. The proposed unified method integrated and blended several sources of information well into a genetic evaluation by avoiding double-counting of contributions due to relationships and due to records. The unified method can also be extended to other types of situations such as single-step genomic or multi-trait evaluations, combining information across different traits.

  8. A new integrable equation combining the modified KdV equation with the negative-order modified KdV equation: multiple soliton solutions and a variety of solitonic solutions

    NASA Astrophysics Data System (ADS)

    Wazwaz, Abdul-Majid

    2018-07-01

    A new third-order integrable equation is constructed via combining the recursion operator of the modified KdV equation (MKdV) and its inverse recursion operator. The developed equation will be termed the modified KdV-negative order modified KdV equation (MKdV-nMKdV). The complete integrability of this equation is confirmed by showing that it nicely possesses the Painlevé property. We obtain multiple soliton solutions for the newly developed integrable equation. Moreover, this equation enjoys a variety of solutions which include solitons, peakons, cuspons, negaton, positon, complexiton and other solutions.

  9. Rapid enumeration of viable bacteria by image analysis

    NASA Technical Reports Server (NTRS)

    Singh, A.; Pyle, B. H.; McFeters, G. A.

    1989-01-01

    A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.

  10. Enhancing the Detection of Dysmorphic Red Blood Cells and Renal Tubular Epithelial Cells with a Modified Urinalysis Protocol.

    PubMed

    Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann

    2017-01-11

    Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis.

  11. Enhancing the Detection of Dysmorphic Red Blood Cells and Renal Tubular Epithelial Cells with a Modified Urinalysis Protocol

    PubMed Central

    Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann

    2017-01-01

    Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis. PMID:28074941

  12. Factors associated to adherence to different treatment schemes with meglumine antimoniate in a clinical trial for cutaneous leishmaniasis.

    PubMed

    Ribeiro, Madelon Novato; Pimentel, Maria Inês Fernandes; Schubach, Armando de Oliveira; Oliveira, Raquel de Vasconcellos Carvalhães de; Teixeira, José Liporage; Leite, Madson Pedro da Silva; Fonseca, Monique; Santos, Ginelza Peres Lima dos; Salgueiro, Mariza Matos; Ferreira e Vasconcellos, Erica de Camargo; Lyra, Marcelo Rosandiski; Saheki, Mauricio Naoto; Valete-Rosalino, Claudia Maria

    2014-01-01

    The favorable outcome of the treatment of a disease is influenced by the adherence to therapy. Our objective was to assess factors associated with adherence to treatment of patients included in a clinical trial of equivalence between the standard and alternative treatment schemes with meglumine antimoniate (MA) in the treatment of cutaneous leishmaniasis (CL), in the state of Rio de Janeiro. Between 2008 and 2011, 57 patients with CL were interviewed using a questionnaire to collect socioeconomic data. The following methods were used for adherence monitoring: counting of vial surplus, monitoring card, Morisky test and modified Morisky test (without the question regarding the schedule); we observed 82.1% (vial return), 86.0% (monitoring card), 66.7% (Morisky test) and 86.0% (modified Morisky test) adherence. There was a strong correlation between the method of vial counting and the monitoring card and modified Morisky test. A significant association was observed between greater adherence to treatment and low dose of MA, as well as with a lower number of people sleeping in the same room. We recommend the use of the modified Morisky test to assess adherence to treatment of CL with MA, because it is a simple method and with a good performance, when compared to other methods.

  13. Influence of observers and stream flow on northern two-lined salamander (Eurycea bislineata bislineata) relative abundance estimates in Acadia and Shenandoah National Parks, USA

    USGS Publications Warehouse

    Crocker, J.B.; Bank, M.S.; Loftin, C.S.; Jung Brown, R.E.

    2007-01-01

    We investigated effects of observers and stream flow on Northern Two-Lined Salamander (Eurycea bislineata bislineata) counts in streams in Acadia (ANP) and Shenandoah National Parks (SNP). We counted salamanders in 22 ANP streams during high flow (May to June 2002) and during low flow (July 2002). We also counted salamanders in SNP in nine streams during high flow (summer 2003) and 11 streams during low flow (summers 2001?02, 2004). In 2002, we used a modified cover-controlled active search method with a first and second observer. In succession, observers turned over 100 rocks along five 1-m belt transects across the streambed. The difference between observers in total salamander counts was not significant. We counted fewer E. b. bislineata during high flow conditions, confirming that detection of this species is reduced during high flow periods and that assessment of stream salamander relative abundance is likely more reliable during low or base flow conditions.

  14. Investigation of energy weighting using an energy discriminating photon counting detector for breast CT

    PubMed Central

    Kalluri, Kesava S.; Mahd, Mufeed; Glick, Stephen J.

    2013-01-01

    Purpose: Breast CT is an emerging imaging technique that can portray the breast in 3D and improve visualization of important diagnostic features. Early clinical studies have suggested that breast CT has sufficient spatial and contrast resolution for accurate detection of masses and microcalcifications in the breast, reducing structural overlap that is often a limiting factor in reading mammographic images. For a number of reasons, image quality in breast CT may be improved by use of an energy resolving photon counting detector. In this study, the authors investigate the improvements in image quality obtained when using energy weighting with an energy resolving photon counting detector as compared to that with a conventional energy integrating detector. Methods: Using computer simulation, realistic CT images of multiple breast phantoms were generated. The simulation modeled a prototype breast CT system using an amorphous silicon (a-Si), CsI based energy integrating detector with different x-ray spectra, and a hypothetical, ideal CZT based photon counting detector with capability of energy discrimination. Three biological signals of interest were modeled as spherical lesions and inserted into breast phantoms; hydroxyapatite (HA) to represent microcalcification, infiltrating ductal carcinoma (IDC), and iodine enhanced infiltrating ductal carcinoma (IIDC). Signal-to-noise ratio (SNR) of these three lesions was measured from the CT reconstructions. In addition, a psychophysical study was conducted to evaluate observer performance in detecting microcalcifications embedded into a realistic anthropomorphic breast phantom. Results: In the energy range tested, improvements in SNR with a photon counting detector using energy weighting was higher (than the energy integrating detector method) by 30%–63% and 4%–34%, for HA and IDC lesions and 12%–30% (with Al filtration) and 32%–38% (with Ce filtration) for the IIDC lesion, respectively. The average area under the receiver operating characteristic curve (AUC) for detection of microcalcifications was higher by greater than 19% (for the different energy weighting methods tested) as compared to the AUC obtained with an energy integrating detector. Conclusions: This study showed that breast CT with a CZT photon counting detector using energy weighting can provide improvements in pixel SNR, and detectability of microcalcifications as compared to that with a conventional energy integrating detector. Since a number of degrading physical factors were not modeled into the photon counting detector, this improvement should be considered as an upper bound on achievable performance. PMID:23927337

  15. Single photon detection in a waveguide-coupled Ge-on-Si lateral avalanche photodiode.

    PubMed

    Martinez, Nicholas J D; Gehl, Michael; Derose, Christopher T; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S

    2017-07-10

    We examine gated-Geiger mode operation of an integrated waveguide-coupled Ge-on-Si lateral avalanche photodiode (APD) and demonstrate single photon detection at low dark count for this mode of operation. Our integrated waveguide-coupled APD is fabricated using a selective epitaxial Ge-on-Si growth process resulting in a separate absorption and charge multiplication (SACM) design compatible with our silicon photonics platform. Single photon detection efficiency and dark count rate is measured as a function of temperature in order to understand and optimize performance characteristics in this device. We report single photon detection of 5.27% at 1310 nm and a dark count rate of 534 kHz at 80 K for a Ge-on-Si single photon avalanche diode. Dark count rate is the lowest for a Ge-on-Si single photon detector in this range of temperatures while maintaining competitive detection efficiency. A jitter of 105 ps was measured for this device.

  16. Counting particles emitted by stratospheric aircraft and measuring size of particles emitted by stratospheric aircraft

    NASA Technical Reports Server (NTRS)

    Wilson, James Charles

    1994-01-01

    The ER-2 condensation nuclei counter (CNC) has been modified to reduce the diffusive losses of particles within the instrument. These changes have been successful in improving the counting efficiency of small particles at low pressures. Two techniques for measuring the size distributions of particles with diameters less than 0.17 micrometers have been evaluated. Both of these methods, the differential mobility analyzer (DMA) and the diffusion battery, have fundamental problems that limit their usefulness for stratospheric applications. We cannot recommend either for this application. Newly developed, alternative methods for measuring small particles include inertial separation with a low-loss critical orifice and thin-plate impactor device. This technique is now used to collect particles in the multisample aerosol collector housed in the ER-2 CNC-2, and shows some promise for particle size measurements when coupled with a CNC as a counting device. The modified focused-cavity aerosol spectrometer (FCAS) can determine the size distribution of particles with ambient diameters as small as about 0.07 micrometers. Data from this instrument indicates the presence of a nuclei mode when CNC-2 indicates high concentrations of particles, but cannot resolve important parameters of the distribution.

  17. Effects of Extended Freezer Storage on the Integrity of Human Milk.

    PubMed

    Ahrabi, Ali Faraghi; Handa, Deepali; Codipilly, Champa N; Shah, Syed; Williams, Janet E; McGuire, Mark A; Potak, Debra; Aharon, Grace Golda; Schanler, Richard J

    2016-10-01

    To examine the integrity (pH, bacterial counts, host defense factors, nutrient contents, and osmolality) of freshly expressed and previously refrigerated human milk subjected to long-term freezer storage. Mothers donated 100 mL of freshly expressed milk. Samples were divided into baseline, storage at -20°C (fresh frozen) for 1, 3, 6, and 9 months, and prior storage at +4°C for 72 hours (refrigerated frozen) before storage at -20°C for 1 to 9 months. Samples were analyzed for pH, total bacterial colony count, gram-positive and gram-negative colony counts, and concentrations of total protein, fat, nonesterified fatty acids, lactoferrin, secretory IgA, and osmolality. Milk pH, total bacterial colony count, and Gram-positive colony counts decreased significantly with freezer storage (P < .001); bacterial counts decreased most rapidly in the refrigerated frozen group. The gram-negative colony count decreased significantly over time (P < .001). Nonesterified fatty acid concentrations increased significantly with time in storage (P < .001). Freezing for up to 9 months did not affect total protein, fat, lactoferrin, secretory IgA, or osmolality in either group. Freezer storage of human milk for 9 months at -20°C is associated with decreasing pH and bacterial counts, but preservation of key macronutrients and immunoactive components, with or without prior refrigeration for 72 hours. These data support current guidelines for freezer storage of human milk for up to 9 months for both freshly expressed and refrigerated milk. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Three-dimensional passive sensing photon counting for object classification

    NASA Astrophysics Data System (ADS)

    Yeom, Seokwon; Javidi, Bahram; Watson, Edward

    2007-04-01

    In this keynote address, we address three-dimensional (3D) distortion-tolerant object recognition using photon-counting integral imaging (II). A photon-counting linear discriminant analysis (LDA) is discussed for classification of photon-limited images. We develop a compact distortion-tolerant recognition system based on the multiple-perspective imaging of II. Experimental and simulation results have shown that a low level of photons is sufficient to classify out-of-plane rotated objects.

  19. Increased Sensitivity to Testicular Toxicity of Transplacental Benzo[a]pyrene Exposure in Male Glutamate Cysteine Ligase Modifier Subunit Knockout (Gclm−/−) Mice

    PubMed Central

    Nakamura, Brooke N.; Mohar, Isaac; Lawson, Gregory W.; Cortés, Mabel M.; Hoang, Yvonne D.; Ortiz, Laura; Patel, Reshma; Rau, Bogdan A.; McConnachie, Lisa A.; Kavanagh, Terrance J.; Luderer, Ulrike

    2012-01-01

    Polycyclic aromatic hydrocarbons (PAHs), like benzo[a]pyrene (BaP), are ubiquitous environmental pollutants formed by the incomplete combustion of organic materials. The tripeptide glutathione (GSH) is a major antioxidant and is important in detoxification of PAH metabolites. Mice null for the modifier subunit of glutamate cysteine ligase (Gclm), the rate-limiting enzyme in GSH synthesis, have decreased GSH concentrations. We investigated the effects of Gclm deletion alone on male fertility and spermatogenesis and its effect on the sensitivity of male embryos to the transplacental testicular toxicity of BaP. Gclm−/− males had dramatically decreased testicular and epididymal GCL enzymatic activity and total GSH concentrations compared with Gclm+/+ littermates. Ratios of reduced to oxidized GSH were significantly increased in Gclm−/− testes. GSH reductase enzymatic activity was increased in Gclm−/− epididymides. We observed no changes in fertility, testicular weights, testicular sperm head counts, or testicular histology and subtle changes in cauda epididymal sperm counts, motility, and morphology in Gclm−/− compared with Gclm+/+ males. Prenatal exposure to BaP from gestational day 7 to 16 was dose dependently associated with significantly decreased testicular and epididymal weights, testicular and epididymal sperm counts, and with vacuolated seminiferous tubules at 10 weeks of age. Gclm−/− males exposed prenatally to BaP had greater decreases in testicular weights, testicular sperm head counts, epididymal sperm counts, and epididymal sperm motility than Gclm+/+ littermates. These results show no effects of Gclm deletion alone on male fertility and testicular spermatogenesis and subtle epididymal effects but support increased sensitivity of Gclm−/− males to the transplacental testicular toxicity of BaP. PMID:22253057

  20. Replication capacity in relation to immunologic and virologic outcomes in HIV-1-infected treatment-naive subjects.

    PubMed

    Skowron, Gail; Spritzler, John G; Weidler, Jodi; Robbins, Gregory K; Johnson, Victoria A; Chan, Ellen S; Asmuth, David M; Gandhi, Rajesh T; Lie, Yolanda; Bates, Michael; Pollard, Richard B

    2009-03-01

    To evaluate the association between baseline (BL) replication capacity (RC) (RCBL) and immunologic/virologic parameters (at BL and after 48 weeks on therapy) in HIV-1-infected subjects initiating antiretroviral therapy. RCBL was determined using a modified Monogram PhenoSense HIV drug susceptibility assay on plasma HIV-1 from 321 treatment-naive subjects from AIDS Clinical Trials Group 384. Univariate and multivariable analyses were performed to determine the association of RCBL with BL and on-therapy virologic and immunologic outcomes. Higher RCBL was associated with lower baseline CD4 (CD4BL) (r = -0.23, P < 0.0001), higher baseline HIV-1 RNA (r = 0.25, P < 0.0001), higher CD4BL activation percent (r = 0.23, P < 0.0001), and lower CD4BL memory count (r = -0.21, P = 0.0002). In a multivariable model, week 48 CD4 increase (DeltaCD448) was associated with lower CD4BL memory count and higher CD4BL-naive percent (P = 0.004, P = 0.015, respectively). The interaction between CD4BL and RCBL was significant (P = 0.018), with a positive association between RCBL and DeltaCD448 in subjects with higher CD4BL and a negative association at lower absCD4BL. At baseline, higher RC was significantly associated with higher HIV-1 RNA, higher CD4 cell activation, lower CD4 cell count, and lower CD4 memory cell count. These factors may interact, directly or indirectly, to modify the extent to which CD4 recovery occurs in patients starting antiretroviral therapy at different CD4BL counts.

  1. Replication Capacity in Relation to Immunologic and Virologic Outcomes in HIV-1 infected, Treatment-Naïve Subjects

    PubMed Central

    Skowron, Gail; Spritzler, John G.; Weidler, Jodi; Robbins, Gregory K.; Johnson, Victoria A.; Chan, Ellen S.; Asmuth, David M.; Gandhi, Rajesh T.; Lie, Yolanda; Bates, Michael; Pollard, Richard B.

    2012-01-01

    Objectives To evaluate the association between baseline (BL) replication capacity (RC) [RCBL] and immunologic/virologic parameters (at BL and after 48 weeks on therapy) in HIV-1 infected subjects initiating antiretroviral therapy. Methods RCBL was determined using a modified Monogram PhenoSense HIV drug susceptibility assay on plasma HIV-1 from 321 treatment-naïve subjects from ACTG384. Univariate and multivariable analyses were performed to determine the association of RCBL with BL and on-therapy virologic and immunologic outcomes. Results Higher RCBL was associated with lower baseline CD4 (CD4BL) (r=−0.23, p<0.0001), higher baseline HIV-1 (RNABL) (r=0.25, p<0.0001), higher CD4BL activation percent (r=0.23, p<0.0001) and lower CD4BL memory count (r=−0.21, p=0.0002). In a multivariable model, week 48 CD4 increase (ΔCD448) was associated with lower CD4BL memory count and higher CD4BL naive percent (p=0.004, p=0.015, respectively). The interaction between CD4BL and RCBL was significant (p=0.018), with a positive association between RCBL and ΔCD448 in subjects with higher CD4BL, and a negative association at lower absCD4BL. Conclusions At baseline, higher RC was significantly associated with higher HIV-1 RNA, higher CD4 cell activation, lower CD4 cell count, and lower CD4 memory cell count. These factors may interact, directly or indirectly, to modify the extent to which CD4 recovery occurs in patients starting antiretroviral therapy at different baseline CD4 counts. PMID:19194319

  2. Evaluation of accuracy and precision of a smartphone based automated parasite egg counting system in comparison to the McMaster and Mini-FLOTAC methods.

    PubMed

    Scare, J A; Slusarewicz, P; Noel, M L; Wielgus, K M; Nielsen, M K

    2017-11-30

    Fecal egg counts are emphasized for guiding equine helminth parasite control regimens due to the rise of anthelmintic resistance. This, however, poses further challenges, since egg counting results are prone to issues such as operator dependency, method variability, equipment requirements, and time commitment. The use of image analysis software for performing fecal egg counts is promoted in recent studies to reduce the operator dependency associated with manual counts. In an attempt to remove operator dependency associated with current methods, we developed a diagnostic system that utilizes a smartphone and employs image analysis to generate automated egg counts. The aims of this study were (1) to determine precision of the first smartphone prototype, the modified McMaster and ImageJ; (2) to determine precision, accuracy, sensitivity, and specificity of the second smartphone prototype, the modified McMaster, and Mini-FLOTAC techniques. Repeated counts on fecal samples naturally infected with equine strongyle eggs were performed using each technique to evaluate precision. Triplicate counts on 36 egg count negative samples and 36 samples spiked with strongyle eggs at 5, 50, 500, and 1000 eggs per gram were performed using a second smartphone system prototype, Mini-FLOTAC, and McMaster to determine technique accuracy. Precision across the techniques was evaluated using the coefficient of variation. In regards to the first aim of the study, the McMaster technique performed with significantly less variance than the first smartphone prototype and ImageJ (p<0.0001). The smartphone and ImageJ performed with equal variance. In regards to the second aim of the study, the second smartphone system prototype had significantly better precision than the McMaster (p<0.0001) and Mini-FLOTAC (p<0.0001) methods, and the Mini-FLOTAC was significantly more precise than the McMaster (p=0.0228). Mean accuracies for the Mini-FLOTAC, McMaster, and smartphone system were 64.51%, 21.67%, and 32.53%, respectively. The Mini-FLOTAC was significantly more accurate than the McMaster (p<0.0001) and the smartphone system (p<0.0001), while the smartphone and McMaster counts did not have statistically different accuracies. Overall, the smartphone system compared favorably to manual methods with regards to precision, and reasonably with regards to accuracy. With further refinement, this system could become useful in veterinary practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Information theoretic approach for assessing image fidelity in photon-counting arrays.

    PubMed

    Narravula, Srikanth R; Hayat, Majeed M; Javidi, Bahram

    2010-02-01

    The method of photon-counting integral imaging has been introduced recently for three-dimensional object sensing, visualization, recognition and classification of scenes under photon-starved conditions. This paper presents an information-theoretic model for the photon-counting imaging (PCI) method, thereby providing a rigorous foundation for the merits of PCI in terms of image fidelity. This, in turn, can facilitate our understanding of the demonstrated success of photon-counting integral imaging in compressive imaging and classification. The mutual information between the source and photon-counted images is derived in a Markov random field setting and normalized by the source-image's entropy, yielding a fidelity metric that is between zero and unity, which respectively corresponds to complete loss of information and full preservation of information. Calculations suggest that the PCI fidelity metric increases with spatial correlation in source image, from which we infer that the PCI method is particularly effective for source images with high spatial correlation; the metric also increases with the reduction in photon-number uncertainty. As an application to the theory, an image-classification problem is considered showing a congruous relationship between the fidelity metric and classifier's performance.

  4. Genetic Modifiers of Neurofibromatosis Type 1-Associated Café-au-Lait Macule Count Identified Using Multi-platform Analysis

    PubMed Central

    Pemov, Alexander; Sung, Heejong; Hyland, Paula L.; Sloan, Jennifer L.; Ruppert, Sarah L.; Baldwin, Andrea M.; Boland, Joseph F.; Bass, Sara E.; Lee, Hyo Jung; Jones, Kristine M.; Zhang, Xijun; Mullikin, James C.; Widemann, Brigitte C.; Wilson, Alexander F.; Stewart, Douglas R.

    2014-01-01

    Neurofibromatosis type 1 (NF1) is an autosomal dominant, monogenic disorder of dysregulated neurocutaneous tissue growth. Pleiotropy, variable expressivity and few NF1 genotype-phenotype correlates limit clinical prognostication in NF1. Phenotype complexity in NF1 is hypothesized to derive in part from genetic modifiers unlinked to the NF1 locus. In this study, we hypothesized that normal variation in germline gene expression confers risk for certain phenotypes in NF1. In a set of 79 individuals with NF1, we examined the association between gene expression in lymphoblastoid cell lines with NF1-associated phenotypes and sequenced select genes with significant phenotype/expression correlations. In a discovery cohort of 89 self-reported European-Americans with NF1 we examined the association between germline sequence variants of these genes with café-au-lait macule (CALM) count, a tractable, tumor-like phenotype in NF1. Two correlated, common SNPs (rs4660761 and rs7161) between DPH2 and ATP6V0B were significantly associated with the CALM count. Analysis with tiled regression also identified SNP rs4660761 as significantly associated with CALM count. SNP rs1800934 and 12 rare variants in the mismatch repair gene MSH6 were also associated with CALM count. Both SNPs rs7161 and rs4660761 (DPH2 and ATP6V0B) were highly significant in a mega-analysis in a combined cohort of 180 self-reported European-Americans; SNP rs1800934 (MSH6) was near-significant in a meta-analysis assuming dominant effect of the minor allele. SNP rs4660761 is predicted to regulate ATP6V0B, a gene associated with melanosome biology. Individuals with homozygous mutations in MSH6 can develop an NF1-like phenotype, including multiple CALMs. Through a multi-platform approach, we identified variants that influence NF1 CALM count. PMID:25329635

  5. Pulmonary actinomycosis

    MedlinePlus

    The health care provider will perform a physical exam, and ask about your medical history and symptoms. Tests that may be done include: Bronchoscopy with culture Complete blood count (CBC) Chest x-ray Chest CT scan Lung biopsy Modified AFB smear of sputum ...

  6. Quantifying the Effect of Pressure Sensitive Paint On Aerodynamic Data

    NASA Technical Reports Server (NTRS)

    Amer, T. R.; Obara, C. J.; Liu, T.

    2003-01-01

    A thin pressure sensitive paint (PSP) coating can slightly modify the overall shape of a wind-tunnel model and produce surface roughness or smoothness that does not exist on the unpainted model. These undesirable changes in model geometry may alter flow over the model, and affect the pressure distribution and aerodynamic forces and moments on the model. This study quantifies the effects of PSP on three models in low-speed, transonic and supersonic flow regimes. At a 95% confidence level, the PSP effects on the integrated forces are insignificant for a slender arrow-wing-fuselage model and delta wing model with two different paints at Mach 0.2, 1.8, and 2.16 relative to the total balance accuracy limit. The data displayed a repeatability of 2.5 drag counts, while the balance accuracy limit was about 5.5 drag counts. At transonic speeds, the paint has a localized effect at high angles of attack and has a resolvable effect on the normal force, which is significant relative to the balance accuracy limit. For low speeds, the PSP coating has a localized effect on the pressure tap measurements, which leads to an appreciable decrease in the pressure tap reading. Moreover, the force and moment measurements had a poor precision, which precluded the ability to measure the PSP effect for this particular test.

  7. Dark-count-less photon-counting x-ray computed tomography system using a YAP-MPPC detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2012-10-01

    A high-sensitive X-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and a dark-count-less photon-counting CT system was developed. X-ray photons are detected using a YAP(Ce) [cerium-doped yttrium aluminum perovskite] single crystal scintillator and an MPPC (multipixel photon counter). Photocurrents are amplified by a high-speed current-voltage amplifier, and smooth event pulses from an integrator are sent to a high-speed comparator. Then, logical pulses are produced from the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The image contrast of gadolinium medium slightly fell with increase in lower-level voltage (Vl) of the comparator. The dark count rate was 0 cps, and the count rate for the CT was approximately 250 kcps.

  8. HgCdTe APD-based linear-mode photon counting components and ladar receivers

    NASA Astrophysics Data System (ADS)

    Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.

    2011-05-01

    Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.

  9. High-Throughput Method for Automated Colony and Cell Counting by Digital Image Analysis Based on Edge Detection

    PubMed Central

    Choudhry, Priya

    2016-01-01

    Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849

  10. Do thawing and warming affect the integrity of human milk?

    PubMed

    Handa, D; Ahrabi, A F; Codipilly, C N; Shah, S; Ruff, S; Potak, D; Williams, J E; McGuire, M A; Schanler, R J

    2014-11-01

    To evaluate the integrity of the human milk (pH, bacterial counts, host defense factors and nutrients) subjected to thawing, warming, refrigeration and maintenance at room temperature. Mothers in the neonatal intensive care unit donated freshly expressed milk. A baseline sample was stored at -80 °C and the remainder of the milk was divided and stored for 7 days at -20 °C. The milk was then subjected to two methods of thawing and warming: tepid water and waterless warmer. Thawed milk also was refrigerated for 24 h prior to warming. Lastly, warmed milk was maintained at room temperature for 4 h to simulate a feeding session. Samples were analyzed for pH, bacterial colony counts, total fat and free fatty acids, and the content of protein, secretory IgA and lactoferrin. Data were analyzed by repeated-measures analysis of variance and paired t test. There were no differences between processing methods and no changes in fat, protein, lactoferrin and secretory immunoglobulin A with processing steps. Milk pH and bacterial colony counts declined while free fatty acids rose with processing. Refrigeration of thawed milk resulted in greater declines in pH and bacteria and increases in free fatty acids. Bacterial colony counts and free fatty acids increased with maintenance at room temperature. The integrity of the milk was affected similarly by the two thawing and warming methods. Thawing and warming change the integrity of previously frozen human milk, but not adversely. Concerns about maintaining warmed milk at room temperature need to be explored.

  11. Bacterial communities of fresh goat meat packaged in modified atmosphere.

    PubMed

    Carrizosa, Elia; Benito, María José; Ruiz-Moyano, Santiago; Hernández, Alejandro; Villalobos, Maria Del Carmen; Martín, Alberto; Córdoba, María de Guía

    2017-08-01

    The objective of this work was to study the growth and development of fortuitous flora and food pathogens in fresh goat meat packaged under modified atmospheres containing two different concentrations of CO 2 . Meat samples were stored at 10 °C under two different modified-atmosphere packing (MAP) conditions: treatment A had 45% CO 2  + 20% O 2  + 35% N 2 and treatment B had 20% CO 2  + 55% O 2  + 25% N 2 . During 14 days of storage, counts of each bacterial group and dominant species identification by 16S rRNA gene sequencing were performed to determine the microbial diversity present. The MAP condition used for treatment A was a more effective gas mixture for increasing the shelf life of fresh goat meat, significantly reducing the total number of viable bacteria and enterobacteria counts. Members of the Enterobacteriaceae family were the most common contaminants, although Hafnia alvei was dominant in treatment A and Serratia proteamaculans in treatment B. Identification studies at the species level showed that different microorganisms develop under different storage conditions, reflecting the importance of gas composition in the modified atmosphere on the bacterial community. This work provides new insights into the microbial changes of goat meat storage under different MAP conditions, which will be beneficial for the meat industry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effect of modified atmosphere and vacuum packaging on some quality characteristics and the shelf-life of "morcilla", a typical cooked blood sausage.

    PubMed

    Cachaldora, Aida; García, Gloria; Lorenzo, José M; García-Fontán, M Camino

    2013-02-01

    The effect of modified atmosphere and vacuum packaging on the shelf-life of "morcilla", a traditional cooked blood sausage, was investigated. A total of 99 "morcillas" were packaged under vacuum and in modified atmosphere using three different gas mixtures: 15:35:50/O(2):N(2):CO(2) (atmosphere 1), 60:40/N(2):CO(2) (atmosphere 2) and 40:60/N(2):CO(2) (atmosphere 3), and stored during 2, 4, 6 and 8 weeks at 4 °C. Shelf life evaluation was based on pH, water activity (a(w)), colour (CIE L*, a*, b*, C* and h*), TBARS formation and microbial counts. The results indicated that, in general, storage time affected (P<0.05) all parameters whereas no significant differences were observed (P>0.05) among packaging conditions. Based on the microbial counts, the shelf-life of "morcilla" would be greater than 8 weeks for all packaging conditions. Samples packaged with high CO(2) concentrations (40:60/N(2):CO(2)) showed the lowest values of TBARS at the end of storage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Silicon Quantum Dots with Counted Antimony Donor Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Meenakshi; Pacheco, Jose L.; Perry, Daniel Lee

    2015-10-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

  14. Generalized seasonal autoregressive integrated moving average models for count data with application to malaria time series with low case numbers.

    PubMed

    Briët, Olivier J T; Amerasinghe, Priyanie H; Vounatsou, Penelope

    2013-01-01

    With the renewed drive towards malaria elimination, there is a need for improved surveillance tools. While time series analysis is an important tool for surveillance, prediction and for measuring interventions' impact, approximations by commonly used Gaussian methods are prone to inaccuracies when case counts are low. Therefore, statistical methods appropriate for count data are required, especially during "consolidation" and "pre-elimination" phases. Generalized autoregressive moving average (GARMA) models were extended to generalized seasonal autoregressive integrated moving average (GSARIMA) models for parsimonious observation-driven modelling of non Gaussian, non stationary and/or seasonal time series of count data. The models were applied to monthly malaria case time series in a district in Sri Lanka, where malaria has decreased dramatically in recent years. The malaria series showed long-term changes in the mean, unstable variance and seasonality. After fitting negative-binomial Bayesian models, both a GSARIMA and a GARIMA deterministic seasonality model were selected based on different criteria. Posterior predictive distributions indicated that negative-binomial models provided better predictions than Gaussian models, especially when counts were low. The G(S)ARIMA models were able to capture the autocorrelation in the series. G(S)ARIMA models may be particularly useful in the drive towards malaria elimination, since episode count series are often seasonal and non-stationary, especially when control is increased. Although building and fitting GSARIMA models is laborious, they may provide more realistic prediction distributions than do Gaussian methods and may be more suitable when counts are low.

  15. Generalized Seasonal Autoregressive Integrated Moving Average Models for Count Data with Application to Malaria Time Series with Low Case Numbers

    PubMed Central

    Briët, Olivier J. T.; Amerasinghe, Priyanie H.; Vounatsou, Penelope

    2013-01-01

    Introduction With the renewed drive towards malaria elimination, there is a need for improved surveillance tools. While time series analysis is an important tool for surveillance, prediction and for measuring interventions’ impact, approximations by commonly used Gaussian methods are prone to inaccuracies when case counts are low. Therefore, statistical methods appropriate for count data are required, especially during “consolidation” and “pre-elimination” phases. Methods Generalized autoregressive moving average (GARMA) models were extended to generalized seasonal autoregressive integrated moving average (GSARIMA) models for parsimonious observation-driven modelling of non Gaussian, non stationary and/or seasonal time series of count data. The models were applied to monthly malaria case time series in a district in Sri Lanka, where malaria has decreased dramatically in recent years. Results The malaria series showed long-term changes in the mean, unstable variance and seasonality. After fitting negative-binomial Bayesian models, both a GSARIMA and a GARIMA deterministic seasonality model were selected based on different criteria. Posterior predictive distributions indicated that negative-binomial models provided better predictions than Gaussian models, especially when counts were low. The G(S)ARIMA models were able to capture the autocorrelation in the series. Conclusions G(S)ARIMA models may be particularly useful in the drive towards malaria elimination, since episode count series are often seasonal and non-stationary, especially when control is increased. Although building and fitting GSARIMA models is laborious, they may provide more realistic prediction distributions than do Gaussian methods and may be more suitable when counts are low. PMID:23785448

  16. Effect of a nano-silver coating on the quality of fresh turkey meat during storage after modified atmosphere or vacuum packaging.

    PubMed

    Deus, D; Kehrenberg, C; Schaudien, D; Klein, G; Krischek, C

    2017-02-01

    Nano-silver is used in consumer products due to its antibacterial properties. The aim of this study was to evaluate the effect of a nano-silver-coated film on the quality of turkey meat during vacuum-sealed and modified atmosphere packaging up to 12 days of storage. In the first part of the experiment, turkey breasts were packaged using either vacuum packaging or modified atmosphere packages (MAPs) and contained films with or without a nano-silver coating (control film). Parameters such as pH, electrical conductivity, color (lightness L*, redness a*), myoglobin redox forms, thiobarbituric acid-reactive substances (TBARS), biogenic amines (BAs), total viable bacterial counts, Pseudomonas species counts, and Enterobacteriaceae species counts were evaluated on storage days 4, 8, and 12. In the second part of the study, the antimicrobial effect of a nano-silver-coated film on turkey breast was evaluated after inoculation with Escherichia coli (E. coli). Turkey meat packaged with the nano-silver film exhibited lower a* values on days 1 (3.15 ± 0.62), 4 (3.90 ± 0.68), and 8 (4.27 ± 0.76) compared to the packaged meat with the control film (3.41 ± 0.73, 4.35 ± 0.94, 4.85 ± 0.89, respectively), indicating special optical properties of nanoparticles. Concerning the BAs, silver packaged meat showed higher values of tyramine on day 12 (1274 ± 392 ng/g meat) and cadaverine on day 4 (1224 ± 435 ng/g meat) compared to the normal packaged products (647 ± 576 and 508 ± 314 ng/g meat, respectively). MAP meat revealed higher L* and TBARS values and lower microbial counts than the vacuum packaged products on all days. The MAP meat also showed lower a* results on days 4 and 8 and higher metmyoglobin (metMb) values on days 8 and 12 compared to th E: vacuum products. In the inoculation study, the microbial counts of the turkey meat were comparable between the two film types. The study showed that the nano-silver coating did not exhibit any advantageous effects on the quality and microbiological parameters of the turkey meat. © 2016 Poultry Science Association Inc.

  17. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    PubMed

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  18. Photon counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy

    PubMed Central

    Driscoll, Jonathan D.; Shih, Andy Y.; Iyengar, Satish; Field, Jeffrey J.; White, G. Allen; Squier, Jeffrey A.; Cauwenberghs, Gert

    2011-01-01

    We present a high-speed photon counter for use with two-photon microscopy. Counting pulses of photocurrent, as opposed to analog integration, maximizes the signal-to-noise ratio so long as the uncertainty in the count does not exceed the gain-noise of the photodetector. Our system extends this improvement through an estimate of the count that corrects for the censored period after detection of an emission event. The same system can be rapidly reconfigured in software for fluorescence lifetime imaging, which we illustrate by distinguishing between two spectrally similar fluorophores in an in vivo model of microstroke. PMID:21471395

  19. Transforming the Classroom. Technology Counts, 2016. Education Week. Volume 35, Issue 35

    ERIC Educational Resources Information Center

    Edwards, Virginia B., Ed.

    2016-01-01

    The 2016 edition of "Education Week's" long-­running "Technology Counts" report combines in-depth reporting and insight from an original national survey to reveal teachers' confidence levels in ed tech, how teachers approach integrating technology into the classroom, and decision-making behind tech products. Contents include:…

  20. freeQuant: A Mass Spectrometry Label-Free Quantification Software Tool for Complex Proteome Analysis.

    PubMed

    Deng, Ning; Li, Zhenye; Pan, Chao; Duan, Huilong

    2015-01-01

    Study of complex proteome brings forward higher request for the quantification method using mass spectrometry technology. In this paper, we present a mass spectrometry label-free quantification tool for complex proteomes, called freeQuant, which integrated quantification with functional analysis effectively. freeQuant consists of two well-integrated modules: label-free quantification and functional analysis with biomedical knowledge. freeQuant supports label-free quantitative analysis which makes full use of tandem mass spectrometry (MS/MS) spectral count, protein sequence length, shared peptides, and ion intensity. It adopts spectral count for quantitative analysis and builds a new method for shared peptides to accurately evaluate abundance of isoforms. For proteins with low abundance, MS/MS total ion count coupled with spectral count is included to ensure accurate protein quantification. Furthermore, freeQuant supports the large-scale functional annotations for complex proteomes. Mitochondrial proteomes from the mouse heart, the mouse liver, and the human heart were used to evaluate the usability and performance of freeQuant. The evaluation showed that the quantitative algorithms implemented in freeQuant can improve accuracy of quantification with better dynamic range.

  1. A compact 7-cell Si-drift detector module for high-count rate X-ray spectroscopy.

    PubMed

    Hansen, K; Reckleben, C; Diehl, I; Klär, H

    2008-05-01

    A new Si-drift detector module for fast X-ray spectroscopy experiments was developed and realized. The Peltier-cooled module comprises a sensor with 7 × 7-mm 2 active area, an integrated circuit for amplification, shaping and detection, storage, and derandomized readout of signal pulses in parallel, and amplifiers for line driving. The compactness and hexagonal shape of the module with a wrench size of 16mm allow very short distances to the specimen and multi-module arrangements. The power dissipation is 186mW. At a shaper peaking time of 190 ns and an integration time of 450 ns an electronic rms noise of ~11 electrons was achieved. When operated at 7 °C, FWHM line widths around 260 and 460 eV (Cu-K α ) were obtained at low rates and at sum-count rates of 1.7 MHz, respectively. The peak shift is below 1% for a broad range of count rates. At 1.7-MHz sum-count rate the throughput loss amounts to 30%.

  2. Does the covariance structure matter in longitudinal modelling for the prediction of future CD4 counts?

    PubMed

    Taylor, J M; Law, N

    1998-10-30

    We investigate the importance of the assumed covariance structure for longitudinal modelling of CD4 counts. We examine how individual predictions of future CD4 counts are affected by the covariance structure. We consider four covariance structures: one based on an integrated Ornstein-Uhlenbeck stochastic process; one based on Brownian motion, and two derived from standard linear and quadratic random-effects models. Using data from the Multicenter AIDS Cohort Study and from a simulation study, we show that there is a noticeable deterioration in the coverage rate of confidence intervals if we assume the wrong covariance. There is also a loss in efficiency. The quadratic random-effects model is found to be the best in terms of correctly calibrated prediction intervals, but is substantially less efficient than the others. Incorrectly specifying the covariance structure as linear random effects gives too narrow prediction intervals with poor coverage rates. Fitting using the model based on the integrated Ornstein-Uhlenbeck stochastic process is the preferred one of the four considered because of its efficiency and robustness properties. We also use the difference between the future predicted and observed CD4 counts to assess an appropriate transformation of CD4 counts; a fourth root, cube root and square root all appear reasonable choices.

  3. Refrigerator storage of expressed human milk in the neonatal intensive care unit.

    PubMed

    Slutzah, Meredith; Codipilly, Champa N; Potak, Debra; Clark, Richard M; Schanler, Richard J

    2010-01-01

    To provide recommendations for refrigerator storage of human milk, the overall integrity (bacterial growth, cell counts, and component concentrations) of milk was examined during 96 hours of storage at 4 degrees C. Fresh milk samples (n = 36) were divided and stored at 4 degrees C for 0, 24, 48, 72, and 96 hours. At each time, pH, white cell count, and osmolality were measured and additional samples were stored at -80 degrees C until analyzed for bacteria and concentrations of lactoferrin, secretory (s)IgA, fat, fatty acids, and protein. There were no significant changes for osmolality, total and Gram-negative bacterial colony counts or concentrations of sIgA, lactoferrin, and fat. Gram-positive colony counts (2.9 to 1.6 x 10(5) colony-forming units per mL), pH (7.21 to 6.68), white blood cell counts (2.31 to 1.85 x 10(6) cells per mL), and total protein (17.5 to 16.7 g/L) declined, and free fatty acid concentrations increased (0.35 to 1.28 g/L) as storage duration increased, P < .001. Changes were minimal and the overall integrity of milk during refrigerator storage was preserved. Fresh mother's milk may be stored at refrigerator temperature for as long as 96 hours.

  4. A study of pile-up in integrated time-correlated single photon counting systems

    NASA Astrophysics Data System (ADS)

    Arlt, Jochen; Tyndall, David; Rae, Bruce R.; Li, David D.-U.; Richardson, Justin A.; Henderson, Robert K.

    2013-10-01

    Recent demonstration of highly integrated, solid-state, time-correlated single photon counting (TCSPC) systems in CMOS technology is set to provide significant increases in performance over existing bulky, expensive hardware. Arrays of single photon single photon avalanche diode (SPAD) detectors, timing channels, and signal processing can be integrated on a single silicon chip with a degree of parallelism and computational speed that is unattainable by discrete photomultiplier tube and photon counting card solutions. New multi-channel, multi-detector TCSPC sensor architectures with greatly enhanced throughput due to minimal detector transit (dead) time or timing channel dead time are now feasible. In this paper, we study the potential for future integrated, solid-state TCSPC sensors to exceed the photon pile-up limit through analytic formula and simulation. The results are validated using a 10% fill factor SPAD array and an 8-channel, 52 ps resolution time-to-digital conversion architecture with embedded lifetime estimation. It is demonstrated that pile-up insensitive acquisition is attainable at greater than 10 times the pulse repetition rate providing over 60 dB of extended dynamic range to the TCSPC technique. Our results predict future CMOS TCSPC sensors capable of live-cell transient observations in confocal scanning microscopy, improved resolution of near-infrared optical tomography systems, and fluorescence lifetime activated cell sorting.

  5. A study of pile-up in integrated time-correlated single photon counting systems.

    PubMed

    Arlt, Jochen; Tyndall, David; Rae, Bruce R; Li, David D-U; Richardson, Justin A; Henderson, Robert K

    2013-10-01

    Recent demonstration of highly integrated, solid-state, time-correlated single photon counting (TCSPC) systems in CMOS technology is set to provide significant increases in performance over existing bulky, expensive hardware. Arrays of single photon single photon avalanche diode (SPAD) detectors, timing channels, and signal processing can be integrated on a single silicon chip with a degree of parallelism and computational speed that is unattainable by discrete photomultiplier tube and photon counting card solutions. New multi-channel, multi-detector TCSPC sensor architectures with greatly enhanced throughput due to minimal detector transit (dead) time or timing channel dead time are now feasible. In this paper, we study the potential for future integrated, solid-state TCSPC sensors to exceed the photon pile-up limit through analytic formula and simulation. The results are validated using a 10% fill factor SPAD array and an 8-channel, 52 ps resolution time-to-digital conversion architecture with embedded lifetime estimation. It is demonstrated that pile-up insensitive acquisition is attainable at greater than 10 times the pulse repetition rate providing over 60 dB of extended dynamic range to the TCSPC technique. Our results predict future CMOS TCSPC sensors capable of live-cell transient observations in confocal scanning microscopy, improved resolution of near-infrared optical tomography systems, and fluorescence lifetime activated cell sorting.

  6. Botulism challenge studies of a modified atmosphere package for fresh mussels: inoculated pack studies.

    PubMed

    Newell, C R; Ma, Li; Doyle, Michael

    2012-06-01

    A series of botulism challenge studies were performed to determine the possibility of production of botulinum toxin in mussels (Mytilus edulis) held under a commercial high-oxygen (60 to 65% O(2)), modified atmosphere packaging (MAP) condition. Spore mixtures of six strains of nonproteolytic Clostridium botulinum were introduced into mussel MAP packages receiving different packaging buffers with or without the addition of lactic acid bacteria. Dye studies and package flipping trials were conducted to ensure internalization of spores by packed mussels. Inoculated mussel packages were stored at normal (4°C) and abusive (12°C) temperatures for 21 and 13 days, respectively, which were beyond the packaged mussels' intended shelf life. Microbiological and chemical analyses were conducted at predetermined intervals (a total of five sampling times at each temperature), including total aerobic plate counts, C. botulinum counts, lactic acid bacterial counts, package headspace gas composition, pH of packaging buffer and mussel meat, and botulinum toxin assays of packaging buffer and mussel meat. Results revealed that C. botulinum inoculated in fresh mussels packed under MAP packaging did not produce toxin, even at an abusive storage temperature and when held beyond their shelf life. No evidence was found that packaging buffers or gas composition influenced the lack of botulinum toxin production in packed mussels.

  7. Development of a homogeneous pulse shape discriminating flow-cell radiation detection system

    NASA Astrophysics Data System (ADS)

    Hastie, K. H.; DeVol, T. A.; Fjeld, R. A.

    1999-02-01

    A homogeneous flow-cell radiation detection system which utilizes coincidence counting and pulse shape discrimination circuitry was assembled and tested with five commercially available liquid scintillation cocktails. Two of the cocktails, Ultima Flo (Packard) and Mono Flow 5 (National Diagnostics) have low viscosities and are intended for flow applications; and three of the cocktails, Optiphase HiSafe 3 (Wallac), Ultima Gold AB (Packard), and Ready Safe (Beckman), have higher viscosities and are intended for static applications. The low viscosity cocktails were modified with 1-methylnaphthalene to increase their capability for alpha/beta pulse shape discrimination. The sample loading and pulse shape discriminator setting were optimized to give the lowest minimum detectable concentration for alpha radiation in a 30 s count time. Of the higher viscosity cocktails, Optiphase HiSafe 3 had the lowest minimum detectable activities for alpha and beta radiation, 0.2 and 0.4 Bq/ml for 233U and 90Sr/ 90Y, respectively, for a 30 s count time. The sample loading was 70% and the corresponding alpha/beta spillover was 5.5%. Of the low viscosity cocktails, Mono Flow 5 modified with 2.5% (by volume) 1-methylnaphthalene resulted in the lowest minimum detectable activities for alpha and beta radiation; 0.3 and 0.5 Bq/ml for 233U and 90Sr/ 90Y, respectively, for a 30 s count time. The sample loading was 50%, and the corresponding alpha/beta spillover was 16.6%. HiSafe 3 at a 10% sample loading was used to evaluate the system under simulated flow conditions.

  8. Trajectory-Based Complexity (TBX): A Modified Aircraft Count to Predict Sector Complexity During Trajectory-Based Operations

    NASA Technical Reports Server (NTRS)

    Prevot, Thomas; Lee, Paul U.

    2011-01-01

    In this paper we introduce a new complexity metric to predict -in real-time- sector complexity for trajectory-based operations (TBO). TBO will be implemented in the Next Generation Air Transportation System (NextGen). Trajectory-Based Complexity (TBX) is a modified aircraft count that can easily be computed and communicated in a TBO environment based upon predictions of aircraft and weather trajectories. TBX is scaled to aircraft count and represents an alternate and additional means to manage air traffic demand and capacity with more consideration of dynamic factors such as weather, aircraft equipage or predicted separation violations, as well as static factors such as sector size. We have developed and evaluated TBX in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center during human-in-the-loop studies of trajectory-based concepts since 2009. In this paper we will describe the TBX computation in detail and present the underlying algorithm. Next, we will describe the specific TBX used in an experiment at NASA's AOL. We will evaluate the performance of this metric using data collected during a controller-inthe- loop study on trajectory-based operations at different equipage levels. In this study controllers were prompted at regular intervals to rate their current workload on a numeric scale. When comparing this real-time workload rating to the TBX values predicted for these time periods we demonstrate that TBX is a better predictor of workload than aircraft count. Furthermore we demonstrate that TBX is well suited to be used for complexity management in TBO and can easily be adjusted to future operational concepts.

  9. Portable multiplicity counter

    DOEpatents

    Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM

    2009-09-01

    A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

  10. MicroCT with energy-resolved photon-counting detectors

    PubMed Central

    Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, BMW; Patt, B E; Frey, E C

    2011-01-01

    The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with Kabsorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences. PMID:21464527

  11. MicroCT with energy-resolved photon-counting detectors.

    PubMed

    Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, B M W; Patt, B E; Frey, E C

    2011-05-07

    The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with K-absorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences.

  12. Sperm Quality during Storage Is Not Affected by the Presence of Antibiotics in EquiPlus Semen Extender but Is Improved by Single Layer Centrifugation

    PubMed Central

    Spergser, Joachim; Kuhl, Juliane; Schmidt, Kathrin; Johannisson, Anders

    2017-01-01

    Contamination of semen with bacteria arises during semen collection and handling. This bacterial contamination is typically controlled by adding antibiotics to semen extenders but intensive usage of antibiotics can lead to the development of bacterial resistance and may be detrimental to sperm quality. The objective of this study was to determine the effects of antibiotics in a semen extender on sperm quality and to investigate the effects of removal of bacteria by modified Single Layer Centrifugation (MSLC) through a colloid. Semen was collected from six adult pony stallions (three ejaculates per male). Aliquots of extended semen were used for MSLC with Equicoll, resulting in four treatment groups: control and MSLC in extender with antibiotics (CA and SA, respectively); control and MSLC in extender without antibiotics (CW and SW, respectively). Sperm motility, membrane integrity, mitochondrial membrane potential and chromatin integrity were evaluated daily by computer-assisted sperm analysis (CASA) and flow cytometry. There were no differences in sperm quality between CA and CW, or between SA and SW, although progressive motility was negatively correlated to total bacterial counts at 0 h. However, MSLC groups showed higher mean total motility (P < 0.001), progressive motility (P < 0.05), membrane integrity (P < 0.0001) and mitochondrial membrane potential (P < 0.05), as well as better chromatin integrity (P < 0.05), than controls. Sperm quality remained higher in the MSLC groups than controls throughout storage. These results indicate that sperm quality was not adversely affected by the presence of antibiotics but was improved considerably by MSLC. PMID:29267226

  13. Screening for Circulating Tumour Cells Allows Early Detection of Cancer and Monitoring of Treatment Effectiveness: An Observational Study

    PubMed Central

    Ried, Karin; Eng, Peter; Sali, Avni

    2017-01-01

    Background: Circulating-Tumour-Cells (CTC) provide a blood biomarker for early carcinogenesis, cancer progression and treatment effectiveness. An increase in CTCs is associated with cancer progression, a CTC decrease with cancer containment or remission. Several technologies have been developed to identify CTC, including the validated Isolation-by-Size-of-Epithelial-Tumour (ISET, Rarecells) technology, combining blood filtration and microscopy using standard histo-pathological criteria. Methods: This observational study compared CTC count to cancer status and cancer risk, by monitoring treatment effectiveness in cancer patients and by screening for CTC in asymptomatic patients with risk factors, including family history of cancer. Results: Between Sept-2014 and Dec-2016 we undertook 600 CTC tests (542 patients), including 50% screening requests of patients without cancer diagnosis but with risk factors. CTC were detected in all cancer patients (n=277, 100%), and in half of the asymptomatic patients screened (50%, 132 out-of 265 patients). Follow-up tests including scans, scheduled within 1-10 months of positive CTC tests, found early cancerous lesions in 20% of screened patients. In 50% of male patients with CTC and normal PSA (prostate-specific-antigen) levels, PSMA-PET scans revealed increased uptake in the prostate, indicative of early prostate cancer. Other types of cancers detected by CTC screening and subsequent scans included early breast, ovarian, lung, or renal cancer. Patients with CTC were advised on integrative approaches including immune-stimulating and anti-carcinogenic nutritional therapies. CTC repeat tests were available in 10% of patients with detected CTC (40 out-of 409 patients, n=98 CTC tests) to assess treatment effectiveness, suggesting nutritional therapies to be beneficial in reducing CTC count. Conclusions: CTC screening provided a highly sensitive biomarker for the early detection of cancer, with higher CTC counts being associated with higher risk of malignancy. CTC monitoring over time indicated treatment effectiveness. Nutrients with anti-carcinogenic properties could reduce CTC count, and included curcumin, garlic, green tea, grape seed, modified citrus pectin, and medicinal mushroom extract. PMID:28843267

  14. Screening for Circulating Tumour Cells Allows Early Detection of Cancer and Monitoring of Treatment Effectiveness: An Observational Study

    PubMed

    Ried, Karin; Eng, Peter; Sali, Avni

    2017-08-27

    Background: Circulating-Tumour-Cells (CTC) provide a blood biomarker for early carcinogenesis, cancer progression and treatment effectiveness. An increase in CTCs is associated with cancer progression, a CTC decrease with cancer containment or remission. Several technologies have been developed to identify CTC, including the validated Isolation-by-Size-of-Epithelial-Tumour (ISET, Rarecells) technology, combining blood filtration and microscopy using standard histo-pathological criteria. Methods: This observational study compared CTC count to cancer status and cancer risk, by monitoring treatment effectiveness in cancer patients and by screening for CTC in asymptomatic patients with risk factors, including family history of cancer. Results: Between Sept-2014 and Dec-2016 we undertook 600 CTC tests (542 patients), including 50% screening requests of patients without cancer diagnosis but with risk factors. CTC were detected in all cancer patients (n=277, 100%), and in half of the asymptomatic patients screened (50%, 132 out-of 265 patients). Follow-up tests including scans, scheduled within 1-10 months of positive CTC tests, found early cancerous lesions in 20% of screened patients. In 50% of male patients with CTC and normal PSA (prostate-specific-antigen) levels, PSMA-PET scans revealed increased uptake in the prostate, indicative of early prostate cancer. Other types of cancers detected by CTC screening and subsequent scans included early breast, ovarian, lung, or renal cancer. Patients with CTC were advised on integrative approaches including immune-stimulating and anti-carcinogenic nutritional therapies. CTC repeat tests were available in 10% of patients with detected CTC (40 outof 409 patients, n=98 CTC tests) to assess treatment effectiveness, suggesting nutritional therapies to be beneficial in reducing CTC count. Conclusions: CTC screening provided a highly sensitive biomarker for the early detection of cancer, with higher CTC counts being associated with higher risk of malignancy. CTC monitoring over time indicated treatment effectiveness. Nutrients with anti-carcinogenic properties could reduce CTC count, and included curcumin, garlic, green tea, grape seed, modified citrus pectin, and medicinal mushroom extract. Creative Commons Attribution License

  15. A chemometrics approach applied to Fourier transform infrared spectroscopy (FTIR) for monitoring the spoilage of fresh salmon (Salmo salar) stored under modified atmospheres.

    PubMed

    Saraiva, C; Vasconcelos, H; de Almeida, José M M M

    2017-01-16

    The aim of this work was to investigate the potential of Fourier transform infrared spectroscopy (FTIR) to detect and predict the bacterial load of salmon fillets (Salmo salar) stored at 3, 8 and 30°C under three packaging conditions: air packaging (AP) and two modified atmospheres constituted by a mixture of 50%N 2 /40%CO 2 /10%O 2 with lemon juice (MAPL) and without lemon juice (MAP). Fresh salmon samples were periodically examined for total viable counts (TVC), specific spoilage organisms (SSO) counts, pH, FTIR and sensory assessment of freshness. Principal components analysis (PCA) allowed identification of the wavenumbers potentially correlated with the spoilage process. Linear discriminant analysis (LDA) of infrared spectral data was performed to support sensory data and to accurately identify samples freshness. The effect of the packaging atmospheres was assessed by microbial enumeration and LDA was used to determine sample packaging from the measured infrared spectra. It was verified that modified atmospheres can decrease significantly the bacterial load of fresh salmon. Lemon juice combined with MAP showed a more pronounced delay in the growth of Brochothrix thermosphacta, Photobacterium phosphoreum, psychrotrophs and H 2 S producers. Partial least squares regression (PLS-R) allowed estimates of TVC and psychrotrophs, lactic acid bacteria, molds and yeasts, Brochothrix thermosphacta, Enterobacteriaceae, Pseudomonas spp. and H 2 S producer counts from the infrared spectral data. For TVC, the root mean square error of prediction (RMSEP) value was 0.78logcfug -1 for an external set of samples. According to the results, FTIR can be used as a reliable, accurate and fast method for real time freshness evaluation of salmon fillets stored under different temperatures and packaging atmospheres. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Integrating count and detection–nondetection data to model population dynamics

    USGS Publications Warehouse

    Zipkin, Elise F.; Rossman, Sam; Yackulic, Charles B.; Wiens, David; Thorson, James T.; Davis, Raymond J.; Grant, Evan H. Campbell

    2017-01-01

    There is increasing need for methods that integrate multiple data types into a single analytical framework as the spatial and temporal scale of ecological research expands. Current work on this topic primarily focuses on combining capture–recapture data from marked individuals with other data types into integrated population models. Yet, studies of species distributions and trends often rely on data from unmarked individuals across broad scales where local abundance and environmental variables may vary. We present a modeling framework for integrating detection–nondetection and count data into a single analysis to estimate population dynamics, abundance, and individual detection probabilities during sampling. Our dynamic population model assumes that site-specific abundance can change over time according to survival of individuals and gains through reproduction and immigration. The observation process for each data type is modeled by assuming that every individual present at a site has an equal probability of being detected during sampling processes. We examine our modeling approach through a series of simulations illustrating the relative value of count vs. detection–nondetection data under a variety of parameter values and survey configurations. We also provide an empirical example of the model by combining long-term detection–nondetection data (1995–2014) with newly collected count data (2015–2016) from a growing population of Barred Owl (Strix varia) in the Pacific Northwest to examine the factors influencing population abundance over time. Our model provides a foundation for incorporating unmarked data within a single framework, even in cases where sampling processes yield different detection probabilities. This approach will be useful for survey design and to researchers interested in incorporating historical or citizen science data into analyses focused on understanding how demographic rates drive population abundance.

  17. Integrating count and detection-nondetection data to model population dynamics.

    PubMed

    Zipkin, Elise F; Rossman, Sam; Yackulic, Charles B; Wiens, J David; Thorson, James T; Davis, Raymond J; Grant, Evan H Campbell

    2017-06-01

    There is increasing need for methods that integrate multiple data types into a single analytical framework as the spatial and temporal scale of ecological research expands. Current work on this topic primarily focuses on combining capture-recapture data from marked individuals with other data types into integrated population models. Yet, studies of species distributions and trends often rely on data from unmarked individuals across broad scales where local abundance and environmental variables may vary. We present a modeling framework for integrating detection-nondetection and count data into a single analysis to estimate population dynamics, abundance, and individual detection probabilities during sampling. Our dynamic population model assumes that site-specific abundance can change over time according to survival of individuals and gains through reproduction and immigration. The observation process for each data type is modeled by assuming that every individual present at a site has an equal probability of being detected during sampling processes. We examine our modeling approach through a series of simulations illustrating the relative value of count vs. detection-nondetection data under a variety of parameter values and survey configurations. We also provide an empirical example of the model by combining long-term detection-nondetection data (1995-2014) with newly collected count data (2015-2016) from a growing population of Barred Owl (Strix varia) in the Pacific Northwest to examine the factors influencing population abundance over time. Our model provides a foundation for incorporating unmarked data within a single framework, even in cases where sampling processes yield different detection probabilities. This approach will be useful for survey design and to researchers interested in incorporating historical or citizen science data into analyses focused on understanding how demographic rates drive population abundance. © 2017 by the Ecological Society of America.

  18. Electrochemical magneto-actuated biosensor for CD4 count in AIDS diagnosis and monitoring.

    PubMed

    Carinelli, S; Xufré Ballesteros, C; Martí, M; Alegret, S; Pividori, M I

    2015-12-15

    The counting of CD4(+) T lymphocytes is a clinical parameter used for AIDS diagnosis and follow-up. As this disease is particularly prevalent in developing countries, simple and affordable CD4 cell counting methods are urgently needed in resource-limited settings. This paper describes an electrochemical magneto-actuated biosensor for CD4 count in whole blood. The CD4(+) T lymphocytes were isolated, preconcentrated and labeled from 100 μL of whole blood by immunomagnetic separation with magnetic particles modified with antiCD3 antibodies. The captured cells were labeled with a biotinylated antiCD4 antibody, followed by the reaction with the electrochemical reporter streptavidin-peroxidase conjugate. The limit of detection for the CD4 counting magneto-actuated biosensor in whole blood was as low as 44 cells μL(-1) while the logistic range was found to be from 89 to 912 cells μL(-1), which spans the whole medical interest range for CD4 counts in AIDS patients. The electrochemical detection together with the immunomagnetic separation confers high sensitivity, resulting in a rapid, inexpensive, robust, user-friendly method for CD4 counting. This approach is a promising alternative for the costly standard flow cytometry and suitable as diagnostic tool at decentralized practitioner sites in low resource settings, especially in less developed countries. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. FPGA-based photon-counting phase-modulation fluorometer and a brief comparison with that operated in a pulsed-excitation mode

    NASA Astrophysics Data System (ADS)

    Iwata, Tetsuo; Taga, Takanori; Mizuno, Takahiko

    2018-02-01

    We have constructed a high-efficiency, photon-counting phase-modulation fluorometer (PC-PMF) using a field-programmable gate array, which is a modified version of the photon-counting fluorometer (PCF) that works in a pulsed-excitation mode (Iwata and Mizuno in Meas Sci Technol 28:075501, 2017). The common working principle for both is the simultaneous detection of the photoelectron pulse train, which covers 64 ns with a 1.0-ns resolution time (1.0 ns/channel). The signal-gathering efficiency was improved more than 100 times over that of conventional time-correlated single-photon-counting at the expense of resolution time depending on the number of channels. The system dead time for building a histogram was eliminated, markedly shortening the measurement time for fluorescent samples with moderately high quantum yields. We describe the PC-PMF and make a brief comparison with the pulsed-excitation PCF in precision, demonstrating the potential advantage of PC-PMF.

  20. Development of low level 226Ra analysis for live fish using gamma-ray spectrometry

    NASA Astrophysics Data System (ADS)

    Chandani, Z.; Prestwich, W. V.; Byun, S. H.

    2017-06-01

    A low level 226Ra analysis method for live fish was developed using a 4π NaI(Tl) gamma-ray spectrometer. In order to find out the best algorithm for accomplishing the lowest detection limit, the gamma-ray spectrum from a 226Ra point was collected and nine different methods were attempted for spectral analysis. The lowest detection limit of 0.99 Bq for an hour counting occurred when the spectrum was integrated in the energy region of 50-2520 keV. To extend 226Ra analysis to live fish, a Monte Carlo simulation model with a cylindrical fish in a water container was built using the MCNP code. From simulation results, the spatial distribution of the efficiency and the efficiency correction factor for the live fish model were determined. The MCNP model will be able to be conveniently modified when a different fish or container geometry is employed as fish grow up in real experiments.

  1. Reconfigurable acquisition system with integrated optics for a portable flow cytometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirleis, Matthew A., E-mail: matthew.kirleis@nrl.navy.mil; Mathews, Scott A.; Verbarg, Jasenka

    2013-11-15

    Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-colormore » excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.« less

  2. Reconfigurable acquisition system with integrated optics for a portable flow cytometer.

    PubMed

    Kirleis, Matthew A; Mathews, Scott A; Verbarg, Jasenka; Erickson, Jeffrey S; Piqué, Alberto

    2013-11-01

    Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

  3. Reconfigurable acquisition system with integrated optics for a portable flow cytometer

    NASA Astrophysics Data System (ADS)

    Kirleis, Matthew A.; Mathews, Scott A.; Verbarg, Jasenka; Erickson, Jeffrey S.; Piqué, Alberto

    2013-11-01

    Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

  4. The effect of abused substances on antenatal and intrapartum fetal testing and well-being.

    PubMed

    Kopel, Ellen; Hill, Washington C

    2013-03-01

    Recognition that use and abuse of substances by pregnant patients perpetuates, despite ongoing efforts to educate the public, necessitates clinicians to integrate understanding of potential effects on antepartum and intrapartum fetal testing into their interpretation and implementation of clinical findings. This includes acknowledging some anticipated alterations in results and selecting the appropriate type and frequency of testing methods and interventions. Certain substances are well documented in terms of expected variations in test results; others are not as clearly defined. An overview of information that may be helpful to the clinician is presented to promote understanding of fetal evaluation performed through common tests such as contraction stress test, the nonstress test, the biophysical profile, the modified biophysical profile, fetal movement counting, and Doppler velocimetry. What evidence is available should be used to assist in defining the actual status of the fetus as best as possible, even when the effects of substances may be unknown or have obscure results.

  5. Signal to noise ratio of energy selective x-ray photon counting systems with pileup.

    PubMed

    Alvarez, Robert E

    2014-11-01

    To derive fundamental limits on the effect of pulse pileup and quantum noise in photon counting detectors on the signal to noise ratio (SNR) and noise variance of energy selective x-ray imaging systems. An idealized model of the response of counting detectors to pulse pileup is used. The model assumes a nonparalyzable response and delta function pulse shape. The model is used to derive analytical formulas for the noise and energy spectrum of the recorded photons with pulse pileup. These formulas are first verified with a Monte Carlo simulation. They are then used with a method introduced in a previous paper [R. E. Alvarez, "Near optimal energy selective x-ray imaging system performance with simple detectors," Med. Phys. 37, 822-841 (2010)] to compare the signal to noise ratio with pileup to the ideal SNR with perfect energy resolution. Detectors studied include photon counting detectors with pulse height analysis (PHA), detectors that simultaneously measure the number of photons and the integrated energy (NQ detector), and conventional energy integrating and photon counting detectors. The increase in the A-vector variance with dead time is also computed and compared to the Monte Carlo results. A formula for the covariance of the NQ detector is developed. The validity of the constant covariance approximation to the Cramèr-Rao lower bound (CRLB) for larger counts is tested. The SNR becomes smaller than the conventional energy integrating detector (Q) SNR for 0.52, 0.65, and 0.78 expected number photons per dead time for counting (N), two, and four bin PHA detectors, respectively. The NQ detector SNR is always larger than the N and Q SNR but only marginally so for larger dead times. Its noise variance increases by a factor of approximately 3 and 5 for the A1 and A2 components as the dead time parameter increases from 0 to 0.8 photons per dead time. With four bin PHA data, the increase in variance is approximately 2 and 4 times. The constant covariance approximation to the CRLB is valid for larger counts such as those used in medical imaging. The SNR decreases rapidly as dead time increases. This decrease places stringent limits on allowable dead times with the high count rates required for medical imaging systems. The probability distribution of the idealized data with pileup is shown to be accurately described as a multivariate normal for expected counts greater than those typically utilized in medical imaging systems. The constant covariance approximation to the CRLB is also shown to be valid in this case. A new formula for the covariance of the NQ detector with pileup is derived and validated.

  6. Signal to noise ratio of energy selective x-ray photon counting systems with pileup

    PubMed Central

    Alvarez, Robert E.

    2014-01-01

    Purpose: To derive fundamental limits on the effect of pulse pileup and quantum noise in photon counting detectors on the signal to noise ratio (SNR) and noise variance of energy selective x-ray imaging systems. Methods: An idealized model of the response of counting detectors to pulse pileup is used. The model assumes a nonparalyzable response and delta function pulse shape. The model is used to derive analytical formulas for the noise and energy spectrum of the recorded photons with pulse pileup. These formulas are first verified with a Monte Carlo simulation. They are then used with a method introduced in a previous paper [R. E. Alvarez, “Near optimal energy selective x-ray imaging system performance with simple detectors,” Med. Phys. 37, 822–841 (2010)] to compare the signal to noise ratio with pileup to the ideal SNR with perfect energy resolution. Detectors studied include photon counting detectors with pulse height analysis (PHA), detectors that simultaneously measure the number of photons and the integrated energy (NQ detector), and conventional energy integrating and photon counting detectors. The increase in the A-vector variance with dead time is also computed and compared to the Monte Carlo results. A formula for the covariance of the NQ detector is developed. The validity of the constant covariance approximation to the Cramèr–Rao lower bound (CRLB) for larger counts is tested. Results: The SNR becomes smaller than the conventional energy integrating detector (Q) SNR for 0.52, 0.65, and 0.78 expected number photons per dead time for counting (N), two, and four bin PHA detectors, respectively. The NQ detector SNR is always larger than the N and Q SNR but only marginally so for larger dead times. Its noise variance increases by a factor of approximately 3 and 5 for the A1 and A2 components as the dead time parameter increases from 0 to 0.8 photons per dead time. With four bin PHA data, the increase in variance is approximately 2 and 4 times. The constant covariance approximation to the CRLB is valid for larger counts such as those used in medical imaging. Conclusions: The SNR decreases rapidly as dead time increases. This decrease places stringent limits on allowable dead times with the high count rates required for medical imaging systems. The probability distribution of the idealized data with pileup is shown to be accurately described as a multivariate normal for expected counts greater than those typically utilized in medical imaging systems. The constant covariance approximation to the CRLB is also shown to be valid in this case. A new formula for the covariance of the NQ detector with pileup is derived and validated. PMID:25370642

  7. A high dynamic range pulse counting detection system for mass spectrometry.

    PubMed

    Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng

    2014-01-30

    A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Better Than Counting: Density Profiles from Force Sampling

    NASA Astrophysics Data System (ADS)

    de las Heras, Daniel; Schmidt, Matthias

    2018-05-01

    Calculating one-body density profiles in equilibrium via particle-based simulation methods involves counting of events of particle occurrences at (histogram-resolved) space points. Here, we investigate an alternative method based on a histogram of the local force density. Via an exact sum rule, the density profile is obtained with a simple spatial integration. The method circumvents the inherent ideal gas fluctuations. We have tested the method in Monte Carlo, Brownian dynamics, and molecular dynamics simulations. The results carry a statistical uncertainty smaller than that of the standard counting method, reducing therefore the computation time.

  9. Modified homotopy perturbation method for solving hypersingular integral equations of the first kind.

    PubMed

    Eshkuvatov, Z K; Zulkarnain, F S; Nik Long, N M A; Muminov, Z

    2016-01-01

    Modified homotopy perturbation method (HPM) was used to solve the hypersingular integral equations (HSIEs) of the first kind on the interval [-1,1] with the assumption that the kernel of the hypersingular integral is constant on the diagonal of the domain. Existence of inverse of hypersingular integral operator leads to the convergence of HPM in certain cases. Modified HPM and its norm convergence are obtained in Hilbert space. Comparisons between modified HPM, standard HPM, Bernstein polynomials approach Mandal and Bhattacharya (Appl Math Comput 190:1707-1716, 2007), Chebyshev expansion method Mahiub et al. (Int J Pure Appl Math 69(3):265-274, 2011) and reproducing kernel Chen and Zhou (Appl Math Lett 24:636-641, 2011) are made by solving five examples. Theoretical and practical examples revealed that the modified HPM dominates the standard HPM and others. Finally, it is found that the modified HPM is exact, if the solution of the problem is a product of weights and polynomial functions. For rational solution the absolute error decreases very fast by increasing the number of collocation points.

  10. Air-guided manual deep lamellar keratoplasty.

    PubMed

    Caporossi, A; Simi, C; Licignano, R; Traversi, C; Balestrazzi, A

    2004-01-01

    To evaluate the efficacy of a new modified technique of deep lamellar keratoplasty (DLK). Nine eyes of eight patients with keratoconus of moderate degree were included. All patients underwent DLK with manual dissection from a limbal side port after an air bubble injection in the anterior chamber. The patients underwent a complete ophthalmologic examination 6 months after the suture removal, evaluating best-corrected visual acuity, corneal thickness, endothelial cell count, and topographic astigmatism. One case (11.1%) was converted to penetrating keratoplasty because of microperforation. In the eight successful cases, 7 eyes (77.8%) achieved 20/30 or better visual acuity 6 months after suture removal. Mean postoperative pachymetry was 604.76 microm (SD 46.76). Specular microscopy 6 months after suture removal revealed average endothelial cell count of 2273/mm2 (SD 229). This modified DLK technique is a safe and effective procedure and could facilitate, after a short learning curve, this kind of surgery with a low risk of conversion to penetrating keratoplasty.

  11. Combined effects of gamma-irradiation and modified atmosphere packaging on quality of some spices.

    PubMed

    Kirkin, Celale; Mitrevski, Blagoj; Gunes, Gurbuz; Marriott, Philip J

    2014-07-01

    Thyme (Thymus vidgaris L.), rosemary (Rosmarinus officinalis L.), black pepper (Piper nigrum L.) and cumin (Cuminum cyminum L.) in ground form were packaged in either air or 100% N2 and γ-irradiated at 3 different irradiation levels (7kGy, 12kGy, 17kGy). Total viable bacterial count, yeast and mould count, colour, essential oil yield and essential oil composition were determined. Microbial load was not detectable after 12kGy irradiation of all samples. Irradiation resulted in significant changes in colour values of rosemary and black pepper. The discolouration of the irradiated black pepper was lower in modified atmosphere packaging (MAP) compared to air packaging. Essential oil yield of irradiated black pepper and cumin was lower in air packaging compared to MAP. Gamma-irradiation generally decreased monoterpenes and increased oxygenated compounds, but the effect was lower in MAP. Overall, spices should be irradiated under an O2-free atmosphere to minimise quality deterioration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Non-plaque-forming virions of Modified Vaccinia virus Ankara express viral genes.

    PubMed

    Lülf, Anna-Theresa; Freudenstein, Astrid; Marr, Lisa; Sutter, Gerd; Volz, Asisa

    2016-12-01

    In cell culture infections with vaccinia virus the number of counted virus particles is substantially higher than the number of plaques obtained by titration. We found that standard vaccine preparations of recombinant Modified Vaccinia virus Ankara produce only about 20-30% plaque-forming virions in fully permissive cell cultures. To evaluate the biological activity of the non-plaque-forming particles, we generated recombinant viruses expressing fluorescent reporter proteins under transcriptional control of specific viral early and late promoters. Live cell imaging and automated counting by fluorescent microscopy indicated that virtually all virus particles can enter cells and switch on viral gene expression. Although most of the non-plaque-forming infections are arrested at the level of viral early gene expression, we detected activation of late viral transcription in 10-20% of single infected cells. Thus, non-plaque-forming particles are biologically active, and likely contribute to the immunogenicity of vaccinia virus vaccines. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Blood-brain barrier integrity, intrathecal immunoactivation, and neuronal injury in HIV.

    PubMed

    Anesten, Birgitta; Yilmaz, Aylin; Hagberg, Lars; Zetterberg, Henrik; Nilsson, Staffan; Brew, Bruce J; Fuchs, Dietmar; Price, Richard W; Gisslén, Magnus

    2016-12-01

    Although blood-brain barrier (BBB) impairment has been reported in HIV-infected individuals, characterization of this impairment has not been clearly defined. BBB integrity was measured by CSF/plasma albumin ratio in this cross-sectional study of 631 HIV-infected individuals and 71 controls. We also analyzed CSF and blood HIV RNA and neopterin, CSF leukocyte count, and neurofilament light chain protein (NFL) concentrations. The HIV-infected participants included untreated neuroasymptomatic patients, patients with untreated HIV-associated dementia (HAD), and participants on suppressive antiretroviral treatment (ART). The albumin ratio was significantly increased in patients with HAD compared to all other groups. There were no significant differences between untreated neuroasymptomatic participants, treated participants, and controls. BBB integrity, however, correlated significantly with CSF leukocyte count, CSF HIV RNA, serum and CSF neopterin, and age in untreated neuroasymptomatic participants. In a multiple linear regression analysis, age, CSF neopterin, and CSF leukocyte count stood out as independent predictors of albumin ratio. A significant correlation was found between albumin ratio and CSF NFL in untreated neuroasymptomatic patients and in participants on ART. Albumin ratio, age, and CD4 cell count were confirmed as independent predictors of CSF NFL in multivariable analysis. BBB disruption was mainly found in patients with HAD, where BBB damage correlated with CNS immunoactivation. Albumin ratios also correlated with CSF inflammatory markers and NFL in untreated neuroasymptomatic participants. These findings give support to the association among BBB deterioration, intrathecal immunoactivation, and neuronal injury in untreated neuroasymptomatic HIV-infected individuals.

  14. Dormancy in Deinococcus sp. UDEC-P1 as a survival strategy to escape from deleterious effects of carbon starvation and temperature.

    PubMed

    Guerra, Matías; González, Karina; González, Carlos; Parra, Boris; Martínez, Miguel

    2015-09-01

    Dormancy is characterized by low metabolism and absence of protein synthesis and cellular division enabling bacterial cells to survive under stress. The aim was to determine if carbon starvation and low temperature are factors that modify the proportion of dormant/active cells in Deinococcus sp. UDEC-P1. By flow cytometry, RedoxSensor Green (RSG) was used to quantify metabolic activity and Propidium Iodide (PI) to evaluate membrane integrity in order to determine the percentage of dormant cells. Cell size and morphology were determined using scanning electronic microscopy. Under carbon starvation at 30°C, Deinococcus sp. UDEC-P1 increased its proportion of dormant cells from 0.1% to 20%, decreased the count of culturable cells and average cell volume decreased 7.1 times. At 4°C, however, the proportion of dormant cells increased only to 6%, without a change in the count of culturable cells and an average cellular volume decrease of 4.1 times and 3% of the dormant cells were able to be awakened. Results indicate a greater proportion of dormant Deinococcus sp. UDEC-P1 cells at 30ºC and it suggests that carbon starvation is more deleterious condition at 30ºC than 4ºC. For this reason Deinococcus sp. UDEC-P1 cells are more likely to enter into dormancy at higher temperature as a strategy to survive. Copyright© by the Spanish Society for Microbiology and Institute for Catalan Studies.

  15. Sequence of neuron origin and neocortical laminar fate: relation to cell cycle of origin in the developing murine cerebral wall

    NASA Technical Reports Server (NTRS)

    Takahashi, T.; Goto, T.; Miyama, S.; Nowakowski, R. S.; Caviness, V. S. Jr

    1999-01-01

    Neurons destined for each region of the neocortex are known to arise approximately in an "inside-to-outside" sequence from a pseudostratified ventricular epithelium (PVE). This sequence is initiated rostrolaterally and propagates caudomedially. Moreover, independently of location in the PVE, the neuronogenetic sequence in mouse is divisible into 11 cell cycles that occur over a 6 d period. Here we use a novel "birth hour" method that identifies small cohorts of neurons born during a single 2 hr period, i.e., 10-20% of a single cell cycle, which corresponds to approximately 1.5% of the 6 d neuronogenetic period. This method shows that neurons arising with the same cycle of the 11 cycle sequence in mouse have common laminar fates even if they arise from widely separated positions on the PVE (neurons of fields 1 and 40) and therefore arise at different embryonic times. Even at this high level of temporal resolution, simultaneously arising cells occupy more than one cortical layer, and there is substantial overlap in the distributions of cells arising with successive cycles. We demonstrate additionally that the laminar representation of cells arising with a given cycle is little if at all modified over the early postnatal interval of histogenetic cell death. We infer from these findings that cell cycle is a neuronogenetic counting mechanism and that this counting mechanism is integral to subsequent processes that determine cortical laminar fate.

  16. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    NASA Astrophysics Data System (ADS)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  17. Pile-up correction algorithm based on successive integration for high count rate medical imaging and radiation spectroscopy

    NASA Astrophysics Data System (ADS)

    Mohammadian-Behbahani, Mohammad-Reza; Saramad, Shahyar

    2018-07-01

    In high count rate radiation spectroscopy and imaging, detector output pulses tend to pile up due to high interaction rate of the particles with the detector. Pile-up effects can lead to a severe distortion of the energy and timing information. Pile-up events are conventionally prevented or rejected by both analog and digital electronics. However, for decreasing the exposure times in medical imaging applications, it is important to maintain the pulses and extract their true information by pile-up correction methods. The single-event reconstruction method is a relatively new model-based approach for recovering the pulses one-by-one using a fitting procedure, for which a fast fitting algorithm is a prerequisite. This article proposes a fast non-iterative algorithm based on successive integration which fits the bi-exponential model to experimental data. After optimizing the method, the energy spectra, energy resolution and peak-to-peak count ratios are calculated for different counting rates using the proposed algorithm as well as the rejection method for comparison. The obtained results prove the effectiveness of the proposed method as a pile-up processing scheme designed for spectroscopic and medical radiation detection applications.

  18. A model for predicting Xanthomonas arboricola pv. pruni growth as a function of temperature

    PubMed Central

    Llorente, Isidre; Montesinos, Emilio; Moragrega, Concepció

    2017-01-01

    A two-step modeling approach was used for predicting the effect of temperature on the growth of Xanthomonas arboricola pv. pruni, causal agent of bacterial spot disease of stone fruit. The in vitro growth of seven strains was monitored at temperatures from 5 to 35°C with a Bioscreen C system, and a calibrating equation was generated for converting optical densities to viable counts. In primary modeling, Baranyi, Buchanan, and modified Gompertz equations were fitted to viable count growth curves over the entire temperature range. The modified Gompertz model showed the best fit to the data, and it was selected to estimate the bacterial growth parameters at each temperature. Secondary modeling of maximum specific growth rate as a function of temperature was performed by using the Ratkowsky model and its variations. The modified Ratkowsky model showed the best goodness of fit to maximum specific growth rate estimates, and it was validated successfully for the seven strains at four additional temperatures. The model generated in this work will be used for predicting temperature-based Xanthomonas arboricola pv. pruni growth rate and derived potential daily doublings, and included as the inoculum potential component of a bacterial spot of stone fruit disease forecaster. PMID:28493954

  19. Solar cycle variation of interstellar neutral He, Ne, O density and pick-up ions along the Earth's orbit

    NASA Astrophysics Data System (ADS)

    Sokół, Justyna M.; Bzowski, Maciej; Kubiak, Marzena A.; Möbius, Eberhard

    2016-06-01

    We simulated the modulation of the interstellar neutral (ISN) He, Ne, and O density and pick-up ion (PUI) production rate and count rate along the Earth's orbit over the solar cycle (SC) from 2002 to 2013 to verify if SC-related effects may modify the inferred ecliptic longitude of the ISN inflow direction. We adopted the classical PUI model with isotropic distribution function and adiabatic cooling, modified by time- and heliolatitude-dependent ionization rates and non-zero injection speed of PUIs. We found that the ionization losses have a noticeable effect on the derivation of the ISN inflow longitude based on the Gaussian fit to the crescent and cone peak locations. We conclude that the non-zero radial velocity of the ISN flow and the energy range of the PUI distribution function that is accumulated are of importance for a precise reproduction of the PUI count rate along the Earth orbit. However, the temporal and latitudinal variations of the ionization in the heliosphere, and particularly their variation on the SC time-scale, may significantly modify the shape of PUI cone and crescent and also their peak positions from year to year and thus bias by a few degrees the derived longitude of the ISN gas inflow direction.

  20. Modified Spectral Fatigue Methods for S-N Curves With MIL-HDBK-5J Coefficients

    NASA Technical Reports Server (NTRS)

    Irvine, Tom; Larsen, Curtis

    2016-01-01

    The rainflow method is used for counting fatigue cycles from a stress response time history, where the fatigue cycles are stress-reversals. The rainflow method allows the application of Palmgren-Miner's rule in order to assess the fatigue life of a structure subject to complex loading. The fatigue damage may also be calculated from a stress response power spectral density (PSD) using the semi-empirical Dirlik, Single Moment, Zhao-Baker and other spectral methods. These methods effectively assume that the PSD has a corresponding time history which is stationary with a normal distribution. This paper shows how the probability density function for rainflow stress cycles can be extracted from each of the spectral methods. This extraction allows for the application of the MIL-HDBK-5J fatigue coefficients in the cumulative damage summation. A numerical example is given in this paper for the stress response of a beam undergoing random base excitation, where the excitation is applied separately by a time history and by its corresponding PSD. The fatigue calculation is performed in the time domain, as well as in the frequency domain via the modified spectral methods. The result comparison shows that the modified spectral methods give comparable results to the time domain rainflow counting method.

  1. Sequence-specific sepsis-related DNA capture and fluorescent labeling in monoliths prepared by single-step photopolymerization in microfluidic devices.

    PubMed

    Knob, Radim; Hanson, Robert L; Tateoka, Olivia B; Wood, Ryan L; Guerrero-Arguero, Israel; Robison, Richard A; Pitt, William G; Woolley, Adam T

    2018-05-21

    Fast determination of antibiotic resistance is crucial in selecting appropriate treatment for sepsis patients, but current methods based on culture are time consuming. We are developing a microfluidic platform with a monolithic column modified with oligonucleotides designed for sequence-specific capture of target DNA related to the Klebsiella pneumoniae carbapenemase (KPC) gene. We developed a novel single-step monolith fabrication method with an acrydite-modified capture oligonucleotide in the polymerization mixture, enabling fast monolith preparation in a microfluidic channel using UV photopolymerization. These prepared columns had a threefold higher capacity compared to monoliths prepared in a multistep process involving Schiff-base DNA attachment. Conditions for denaturing, capture and fluorescence labeling using hybridization probes were optimized with synthetic 90-mer oligonucleotides. These procedures were applied for extraction of a PCR amplicon from the KPC antibiotic resistance gene in bacterial lysate obtained from a blood sample spiked with E. coli. The results showed similar eluted peak areas for KPC amplicon extracted from either hybridization buffer or bacterial lysate. Selective extraction of the KPC DNA was verified by real time PCR on eluted fractions. These results show great promise for application in an integrated microfluidic diagnostic system that combines upstream blood sample preparation and downstream single-molecule counting detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Characterization of a hybrid energy-resolving photon-counting detector

    NASA Astrophysics Data System (ADS)

    Zang, A.; Pelzer, G.; Anton, G.; Ballabriga Sune, R.; Bisello, F.; Campbell, M.; Fauler, A.; Fiederle, M.; Llopart Cudie, X.; Ritter, I.; Tennert, F.; Wölfel, S.; Wong, W. S.; Michel, T.

    2014-03-01

    Photon-counting detectors in medical x-ray imaging provide a higher dose efficiency than integrating detectors. Even further possibilities for imaging applications arise, if the energy of each photon counted is measured, as for example K-edge-imaging or optimizing image quality by applying energy weighting factors. In this contribution, we show results of the characterization of the Dosepix detector. This hybrid photon- counting pixel detector allows energy resolved measurements with a novel concept of energy binning included in the pixel electronics. Based on ideas of the Medipix detector family, it provides three different modes of operation: An integration mode, a photon-counting mode, and an energy-binning mode. In energy-binning mode, it is possible to set 16 energy thresholds in each pixel individually to derive a binned energy spectrum in every pixel in one acquisition. The hybrid setup allows using different sensor materials. For the measurements 300 μm Si and 1 mm CdTe were used. The detector matrix consists of 16 x 16 square pixels for CdTe (16 x 12 for Si) with a pixel pitch of 220 μm. The Dosepix was originally intended for applications in the field of radiation measurement. Therefore it is not optimized towards medical imaging. The detector concept itself still promises potential as an imaging detector. We present spectra measured in one single pixel as well as in the whole pixel matrix in energy-binning mode with a conventional x-ray tube. In addition, results concerning the count rate linearity for the different sensor materials are shown as well as measurements regarding energy resolution.

  3. Computer Simulation of the Population Growth (Schizosaccharomyces Pombe) Experiment.

    ERIC Educational Resources Information Center

    Daley, Michael; Hillier, Douglas

    1981-01-01

    Describes a computer program (available from authors) developed to simulate "Growth of a Population (Yeast) Experiment." Students actively revise the counting techniques with realistically simulated haemocytometer or eye-piece grid and are reminded of the necessary dilution technique. Program can be modified to introduce such variables…

  4. Improving the numerical integration solution of satellite orbits in the presence of solar radiation pressure using modified back differences

    NASA Technical Reports Server (NTRS)

    Lundberg, J. B.; Feulner, M. R.; Abusali, P. A. M.; Ho, C. S.

    1991-01-01

    The method of modified back differences, a technique that significantly reduces the numerical integration errors associated with crossing shadow boundaries using a fixed-mesh multistep integrator without a significant increase in computer run time, is presented. While Hubbard's integral approach can produce significant improvements to the trajectory solution, the interpolation method provides the best overall results. It is demonstrated that iterating on the point mass term correction is also important for achieving the best overall results. It is also shown that the method of modified back differences can be implemented with only a small increase in execution time.

  5. Thrombocytopenia associated with vaccination of a dog with a modified-live paramyxovirus vaccine.

    PubMed

    McAnulty, J F; Rudd, R G

    1985-06-01

    Thrombocytopenia (10,000/mm3), with hematochezia and melena, appeared in a dog 8 days after it was given modified-live canine distemper, virus vaccine and persisted for approximately 5 days. Clinical investigation discounted other possible causes of thrombocytopenia; the condition was considered to be associated with vaccination. The problem spontaneously resolved. The appearance of thrombocytopenia after modified-live canine distemper virus vaccination is not unknown and may assume a severe form. This condition may be mistaken for idiopathic thrombocytopenia of immune origin, and in other instances, it may contribute significantly to surgical risk if concurrent coagulation disorders are present. Administration of levamisole HCl may alleviate the decrease in platelet count in affected animals.

  6. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development

    NASA Astrophysics Data System (ADS)

    Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Lazǎr, Veronica; Chifiriuc, Mariana Carmen

    2012-12-01

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.

  7. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development

    PubMed Central

    2012-01-01

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues. PMID:23272823

  8. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development.

    PubMed

    Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Laz R, Veronica; Chifiriuc, Mariana Carmen

    2012-12-31

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.

  9. Fast and High Dynamic Range Imaging with Superconducting Tunnel Junction Detectors

    NASA Astrophysics Data System (ADS)

    Matsuo, Hiroshi

    2014-08-01

    We have demonstrated a combined test of the submillimeter-wave SIS photon detectors and GaAs-JFET cryogenic integrated circuits. A relatively large background photo-current can be read out by fast-reset integrating amplifiers. An integration time of 1 ms enables fast frame rate readout and large dynamic range imaging, with an expected dynamic range of 8,000 in 1 ms. Ultimate fast and high dynamic range performance of superconducting tunnel junction detectors (STJ) will be obtained when photon counting capabilities are employed. In the terahertz frequencies, when input photon rate of 100 MHz is measured, the photon bunching gives us enough timing resolution to be used as phase information of intensity fluctuation. Application of photon statistics will be a new tool in the terahertz frequency region. The design parameters of STJ terahertz photon counting detectors are discussed.

  10. [Comments on policy--elderly count for much, or counting the elderly? A new statement on policy for the elderly].

    PubMed

    Knapen, M; van der Zanden, G H

    1990-12-01

    The Dutch government has published a new white paper 'Elderly count for much' on policy for the aged. In this document the central principle for social policy is the integration of the elderly in society. Old age policy is characterized as 'integral policy' that is it tries to integrate the traditional fields of social and economic policy, and as 'complementary' policy, that is it tries to complement general policy. The main characteristics of the action program 1990-1994 include: prevention, the integration of housing and services, care for elderly with chronic diseases, education, strengthening of labor-market participation of 50+, the position of elderly women and societal attitudes towards aging and the elderly. In this comment it is argued that this white paper initiates positive developments, but there remain several minor and major problems. We are critical about the role of education, the instruments for an active labor-market policy, the lack of attention for the European dimension, and about the lack of attention for future developments in generational equity and age-rationing of service allocation. We appreciate the attention for age discrimination, and possibilities for longitudinal research. We conclude that 'integrated policy' is only in its initial phase. In this white paper the government is only successful in an integrated policy in the fields of housing and care, not in other fields like technology, labor and education. 'Complementary' policy is not enough to create a firm infrastructure in the aging field. If initiatives in the field of aging are considered as 'extra's' this policy will soon be confronted with the boundaries it creates itself. Although attention for the challenges of graying is growing, old age policy is still marginal compared to the main general policy.

  11. Bondi Accretion and the Problem of the Missing Isolated Neutron Stars

    NASA Technical Reports Server (NTRS)

    Perna, Rosalba; Narayan, Ramesh; Rybicki, George; Stella, Luigi; Treves, Aldo

    2003-01-01

    A large number of neutron stars (NSs), approximately 10(exp 9), populate the Galaxy, but only a tiny fraction of them is observable during the short radio pulsar lifetime. The majority of these isolated NSs, too cold to be detectable by their own thermal emission, should be visible in X-rays as a result of accretion from the interstellar medium. The ROSAT All-Sky Survey has, however, shown that such accreting isolated NSs are very elusive: only a few tentative candidates have been identified, contrary to theoretical predictions that up to several thousand should be seen. We suggest that the fundamental reason for this discrepancy lies in the use of the standard Bondi formula to estimate the accretion rates. We compute the expected source counts using updated estimates of the pulsar velocity distribution, realistic hydrogen atmosphere spectra, and a modified expression for the Bondi accretion rate, as suggested by recent MHD simulations and supported by direct observations in the case of accretion around supermassive black holes in nearby galaxies and in our own. We find that, whereas the inclusion of atmospheric spectra partly compensates for the reduction in the counts due to the higher mean velocities of the new distribution, the modified Bondi formula dramatically suppresses the source counts. The new predictions are consistent with a null detection at the ROSAT sensitivity.

  12. Reliability of Classifying Multiple Sclerosis Disease Activity Using Magnetic Resonance Imaging in a Multiple Sclerosis Clinic

    PubMed Central

    Altay, Ebru Erbayat; Fisher, Elizabeth; Jones, Stephen E.; Hara-Cleaver, Claire; Lee, Jar-Chi; Rudick, Richard A.

    2013-01-01

    Objective To assess the reliability of new magnetic resonance imaging (MRI) lesion counts by clinicians in a multiple sclerosis specialty clinic. Design An observational study. Setting A multiple sclerosis specialty clinic. Patients Eighty-five patients with multiple sclerosis participating in a National Institutes of Health–supported longitudinal study were included. Intervention Each patient had a brain MRI scan at entry and 6 months later using a standardized protocol. Main Outcome Measures The number of new T2 lesions, newly enlarging T2 lesions, and gadolinium-enhancing lesions were measured on the 6-month MRI using a computer-based image analysis program for the original study. For this study, images were reanalyzed by an expert neuroradiologist and 3 clinician raters. The neuroradiologist evaluated the original image pairs; the clinicians evaluated image pairs that were modified to simulate clinical practice. New lesion counts were compared across raters, as was classification of patients as MRI active or inactive. Results Agreement on lesion counts was highest for gadolinium-enhancing lesions, intermediate for new T2 lesions, and poor for enlarging T2 lesions. In 18% to 25% of the cases, MRI activity was classified differently by the clinician raters compared with the neuroradiologist or computer program. Variability among the clinical raters for estimates of new T2 lesions was affected most strongly by the image modifications that simulated low image quality and different head position. Conclusions Between-rater variability in new T2 lesion counts may be reduced by improved standardization of image acquisitions, but this approach may not be practical in most clinical environments. Ultimately, more reliable, robust, and accessible image analysis methods are needed for accurate multiple sclerosis disease-modifying drug monitoring and decision making in the routine clinic setting. PMID:23599930

  13. Reduction of Radon Progeny in Indoor Air.

    DTIC Science & Technology

    1986-03-01

    arises from indoor radon is due * 4 to inhalation of the short-lived radon daughters Ra-A, Ra-B, and Ra-C. These decay products are formed from the alpha...concentrations of radon daughters 40 ’ in an air sample from the gross alpha counting of a filter 50 ’ in accordance with the modified Tsivoglou method. 60 ’ 70...8217 The modified Tsivoglou method may be found in " Measurement 80 ’ of Radon Daughters in Air," Health Physics, 23, : pp7S3-789 90 ’ (19𔃼). 95 100 The

  14. Case studies in forensic soil examinations.

    PubMed

    Petraco, Nicholas; Kubic, Thomas A; Petraco, Nicholas D K

    2008-07-04

    The examination and comparison of forensic soil samples is discussed. The origin of a simple and easy to learn procedure used and modified by the authors is reviewed. The process begins with a preliminary observation, removal of artifacts, and sieving of each specimen. A specific size fraction is split into three fractions for color matching, polarized light microscopy (PLM) examination (particle counting) and optional gradient comparison. Next, several cases are reviewed in which the modified method was used to evaluate the likelihood of common origin for questioned and known specimens.

  15. A multi-threaded version of MCFM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, John M.; Ellis, R. Keith; Giele, Walter T.

    We report on our findings modifying MCFM using OpenMP to implement multi-threading. By using OpenMP, the modified MCFM will execute on any processor, automatically adjusting to the number of available threads. We then modified the integration routine VEGAS to distribute the event evaluation over the threads, while combining all events at the end of every iteration to optimize the numerical integration. Furthermore, we took special care so that the results of the Monte Carlo integration were independent of the number of threads used, to facilitate the validation of the OpenMP version of MCFM.

  16. Total mesophilic counts underestimate in many cases the contamination levels of psychrotrophic lactic acid bacteria (LAB) in chilled-stored food products at the end of their shelf-life.

    PubMed

    Pothakos, Vasileios; Samapundo, Simbarashe; Devlieghere, Frank

    2012-12-01

    The major objective of this study was to determine the role of psychrotrophic lactic acid bacteria (LAB) in spoilage-associated phenomena at the end of the shelf-life of 86 various packaged (air, vacuum, modified-atmosphere) chilled-stored retail food products. The current microbiological standards, which are largely based on the total viable mesophilic counts lack discriminatory capacity to detect psychrotrophic LAB. A comparison between the total viable counts on plates incubated at 30 °C (representing the mesophiles) and at 22 °C (indicating the psychrotrophs) for 86 food samples covering a wide range - ready-to-eat vegetable salads, fresh raw meat, cooked meat products and composite food - showed that a consistent underestimation of the microbial load occurs when the total aerobic mesophilic counts are used as a shelf-life parameter. In 38% of the samples, the psychrotrophic counts had significantly higher values (+0.5-3 log CFU/g) than the corresponding total aerobic mesophilic counts. A total of 154 lactic acid bacteria, which were unable to proliferate at 30 °C were isolated. In addition, a further 43 with a poor recovery at this temperature were also isolated. This study highlights the potential fallacy of the total aerobic mesophilic count as a reference shelf-life parameter for chilled food products as it can often underestimate the contamination levels at the end of the shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Study on ultra-fast single photon counting spectrometer based on PCI

    NASA Astrophysics Data System (ADS)

    Zhang, Xi-feng

    2010-10-01

    The time-correlated single photon counting spectrometer developed uses PCI bus technology. We developed the ultrafast data acquisition card based on PCI, replace multi-channel analyzer primary. The system theory and design of the spectrometer are presented in detail, and the process of operation is introduced with the integration of the system. Many standard samples have been measured and the data have been analyzed and contrasted. Experimental results show that the spectrometer, s sensitive is single photon counting, and fluorescence life-span and time resolution is picosecond level. And the instrument could measure time-resolved spectroscopy.

  18. The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7

    NASA Technical Reports Server (NTRS)

    Lisle, J. T.; Pyle, B. H.; McFeters, G. A.

    1999-01-01

    A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.

  19. Statistical approaches to the analysis of point count data: A little extra information can go a long way

    USGS Publications Warehouse

    Farnsworth, G.L.; Nichols, J.D.; Sauer, J.R.; Fancy, S.G.; Pollock, K.H.; Shriner, S.A.; Simons, T.R.; Ralph, C. John; Rich, Terrell D.

    2005-01-01

    Point counts are a standard sampling procedure for many bird species, but lingering concerns still exist about the quality of information produced from the method. It is well known that variation in observer ability and environmental conditions can influence the detection probability of birds in point counts, but many biologists have been reluctant to abandon point counts in favor of more intensive approaches to counting. However, over the past few years a variety of statistical and methodological developments have begun to provide practical ways of overcoming some of the problems with point counts. We describe some of these approaches, and show how they can be integrated into standard point count protocols to greatly enhance the quality of the information. Several tools now exist for estimation of detection probability of birds during counts, including distance sampling, double observer methods, time-depletion (removal) methods, and hybrid methods that combine these approaches. Many counts are conducted in habitats that make auditory detection of birds much more likely than visual detection. As a framework for understanding detection probability during such counts, we propose separating two components of the probability a bird is detected during a count into (1) the probability a bird vocalizes during the count and (2) the probability this vocalization is detected by an observer. In addition, we propose that some measure of the area sampled during a count is necessary for valid inferences about bird populations. This can be done by employing fixed-radius counts or more sophisticated distance-sampling models. We recommend any studies employing point counts be designed to estimate detection probability and to include a measure of the area sampled.

  20. Assessment of dual-point drag reduction for an executive-jet modified airfoil section

    NASA Technical Reports Server (NTRS)

    Allison, Dennis O.; Mineck, Raymond E.

    1996-01-01

    This paper presents aerodynamic characteristics and pressure distributions for an executive-jet modified airfoil and discusses drag reduction relative to a baseline airfoil for two cruise design points. A modified airfoil was tested in the adaptive-wall test section of the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) for Mach numbers ranging from 0.250 to 0.780 and chord Reynolds numbers ranging from 3.0 x 10(exp 6) to 18.0 x 10(exp 6). The angle of attack was varied from minus 2 degrees to almost 10 degrees. Boundary-layer transition was fixed at 5 percent of chord on both the upper and lower surfaces of the model for most of the test. The two design Mach numbers were 0.654 and 0.735, chord Reynolds numbers were 4.5 x 10(exp 6) and 8.9 x 10(exp 6), and normal-force coefficients were 0.98 and 0.51. Test data are presented graphically as integrated force and moment coefficients and chordwise pressure distributions. The maximum normal-force coefficient decreases with increasing Mach number. At a constant normal-force coefficient in the linear region, as Mach number increases an increase occurs in the slope of normal-force coefficient versus angle of attack, negative pitching-moment coefficient, and drag coefficient. With increasing Reynolds number at a constant normal-force coefficient, the pitching-moment coefficient becomes more negative and the drag coefficient decreases. The pressure distributions reveal that when present, separation begins at the trailing edge as angle of attack is increased. The modified airfoil, which is designed with pitching moment and geometric constraints relative to the baseline airfoil, achieved drag reductions for both design points (12 and 22 counts). The drag reductions are associated with stronger suction pressures in the first 10 percent of the upper surface and weakened shock waves.

  1. Glycation, oxidation and glycoxidation of IgG: a biophysical, biochemical, immunological and hematological study.

    PubMed

    Islam, Sidra; Moinuddin; Mir, Abdul Rouf; Raghav, Alok; Habib, Safia; Alam, Khursheed; Ali, Asif

    2017-09-12

    Glycation and oxidation induce structural alterations in the proteins in an interdependent manner with consequent pathological implications. The published literature presents wide range of modifications in conformational characteristics of proteins by glycation and oxidation; however, there is little data that could elaborate the cumulative effect of both the processes. This study has analysed the modifications in IgG by methylglyoxal (MG) (glycative stress), hydroxyl radical ([Formula: see text]) (oxidative stress) and by their combined action i.e. [Formula: see text] treatment of MG glycated IgG (glycoxidation). It further addresses the implications of the altered structural integrity of IgG on its immunological characteristics and impact on haematological parameters in rabbits. Using circular dichroism, FTIR, SDS-PAGE analysis, thioflavin-T fluorescence assay, congo red absorbance analysis, dynamic light scattering, transmission electron microscopy, ELISA, blood cell counts and rectal temperature studies, we report that the glycoxidative modification caused maximum alteration in the IgG as compared to the glycatively and oxidatively modified protein. Far-UV CD results confirmed the highest decline in the beta-pleated sheet content of the protein by glycoxidation. The damage led to the reduced flexibility and enhanced electronic interactions in IgG as observed by near-UV CD. Modifications caused cross-linking and adduct formation in the serum protein. The electron micrograph confirmed amorphous aggregation in modified IgG. The modifications increased the hydrodynamic radius of IgG by allowing the attachment of [Formula: see text] and MG residues. The glycoxidatively modified IgG induced the maximum antibody titres that showed high specificity towards the altered IgG. The glycoxidation of IgG leads to activation of inflammatory pathways.

  2. Usability of small impact craters on small surface areas in crater count dating: Analysing examples from the Harmakhis Vallis outflow channel, Mars

    NASA Astrophysics Data System (ADS)

    Kukkonen, S.; Kostama, V.-P.

    2018-05-01

    The availability of very high-resolution images has made it possible to extend crater size-frequency distribution studies to small, deca/hectometer-scale craters. This has enabled the dating of small and young surface units, as well as recent, short-time and small-scale geologic processes that have occurred on the units. Usually, however, the higher the spatial resolution of space images is, the smaller area is covered by the images. Thus the use of single, very high-resolution images in crater count age determination may be debatable if the images do not cover the studied region entirely. Here we compare the crater count results for the floor of the Harmakhis Vallis outflow channel obtained from the images of the ConTeXt camera (CTX) and High Resolution Imaging Science Experiment (HiRISE) aboard the Mars Reconnaissance Orbiter (MRO). The CTX images enable crater counts for entire units on the Harmakhis Vallis main valley, whereas the coverage of the higher-resolution HiRISE images is limited and thus the images can only be used to date small parts of the units. Our case study shows that the crater count data based on small impact craters and small surface areas mainly correspond with the crater count data based on larger craters and more extensive counting areas on the same unit. If differences between the results were founded, they could usually be explained by the regional geology. Usually, these differences appeared when at least one cratering model age is missing from either of the crater datasets. On the other hand, we found only a few cases in which the cratering model ages were completely different. We conclude that the crater counts using small impact craters on small counting areas provide useful information about the geological processes which have modified the surface. However, it is important to remember that all the crater counts results obtained from a specific counting area always primarily represent the results from the counting area-not the whole unit. On the other hand, together with crater count results from extensive counting areas and lower-resolution images, crater counts on small counting areas but by using very high-resolution images is a very valuable tool for obtaining unique additional information about the local processes on the surface units.

  3. Blood–brain barrier integrity, intrathecal immunoactivation, and neuronal injury in HIV

    PubMed Central

    Yilmaz, Aylin; Hagberg, Lars; Zetterberg, Henrik; Nilsson, Staffan; Brew, Bruce J.; Fuchs, Dietmar; Price, Richard W.; Gisslén, Magnus

    2016-01-01

    Objective: Although blood–brain barrier (BBB) impairment has been reported in HIV-infected individuals, characterization of this impairment has not been clearly defined. Methods: BBB integrity was measured by CSF/plasma albumin ratio in this cross-sectional study of 631 HIV-infected individuals and 71 controls. We also analyzed CSF and blood HIV RNA and neopterin, CSF leukocyte count, and neurofilament light chain protein (NFL) concentrations. The HIV-infected participants included untreated neuroasymptomatic patients, patients with untreated HIV-associated dementia (HAD), and participants on suppressive antiretroviral treatment (ART). Results: The albumin ratio was significantly increased in patients with HAD compared to all other groups. There were no significant differences between untreated neuroasymptomatic participants, treated participants, and controls. BBB integrity, however, correlated significantly with CSF leukocyte count, CSF HIV RNA, serum and CSF neopterin, and age in untreated neuroasymptomatic participants. In a multiple linear regression analysis, age, CSF neopterin, and CSF leukocyte count stood out as independent predictors of albumin ratio. A significant correlation was found between albumin ratio and CSF NFL in untreated neuroasymptomatic patients and in participants on ART. Albumin ratio, age, and CD4 cell count were confirmed as independent predictors of CSF NFL in multivariable analysis. Conclusions: BBB disruption was mainly found in patients with HAD, where BBB damage correlated with CNS immunoactivation. Albumin ratios also correlated with CSF inflammatory markers and NFL in untreated neuroasymptomatic participants. These findings give support to the association among BBB deterioration, intrathecal immunoactivation, and neuronal injury in untreated neuroasymptomatic HIV-infected individuals. PMID:27868081

  4. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    PubMed

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.

  5. Development of an integrated semi-automated system for in vitro pharmacodynamic modelling.

    PubMed

    Wang, Liangsu; Wismer, Michael K; Racine, Fred; Conway, Donald; Giacobbe, Robert A; Berejnaia, Olga; Kath, Gary S

    2008-11-01

    The aim of this study was to develop an integrated system for in vitro pharmacodynamic modelling of antimicrobials with greater flexibility, easier control and better accuracy than existing in vitro models. Custom-made bottle caps, fittings, valve controllers and a modified bench-top shaking incubator were used. A temperature-controlled automated sample collector was built. Computer software was developed to manage experiments and to control the entire system including solenoid pinch valves, peristaltic pumps and the sample collector. The system was validated by pharmacokinetic simulations of linezolid 600 mg infusion. The antibacterial effect of linezolid against multiple Staphylococcus aureus strains was also studied in this system. An integrated semi-automated bench-top system was built and validated. The temperature-controlled automated sample collector allowed unattended collection and temporary storage of samples. The system software reduced the labour necessary for many tasks and also improved the timing accuracy for performing simultaneous actions in multiple parallel experiments. The system was able to simulate human pharmacokinetics of linezolid 600 mg intravenous infusion accurately. A pharmacodynamic study of linezolid against multiple S. aureus strains with a range of MICs showed that the required 24 h free drug AUC/MIC ratio was approximately 30 in order to keep the organism counts at the same level as their initial inoculum and was about > or = 68 in order to achieve > 2 log(10) cfu/mL reduction in the in vitro model. The integrated semi-automated bench-top system provided the ability to overcome many of the drawbacks of existing in vitro models. It can be used for various simple or complicated pharmacokinetic/pharmacodynamic studies efficiently and conveniently.

  6. The Lambert-Beer law in time domain form and its application.

    PubMed

    Mosorov, Volodymyr

    2017-10-01

    The majority of current radioisotope gauges utilize measurements of intensity for a chosen sampling time interval using a detector. Such an approach has several disadvantages: temporal resolution of the gauge is fixed and the accuracy of the measurements is not the same for different count rate. The solution can be the use of a stronger radioactive source, but it will be conflicted with ALARA (As Low As Reasonably Achievable) principle. Therefore, the article presents an alternative approach which is based on modified Lambert-Beer law. The basis of the approach is the registration of time intervals instead of the registration of counts. It allows to increase the temporal resolution of a gauge without the necessity of using a stronger radioactive source and the accuracy of the measurements will not depend on count rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Constraint counting for frictional jamming

    NASA Astrophysics Data System (ADS)

    Quint, D. A.; Henkes, S.; Schwarz, J. M.

    2012-02-01

    While the frictionless jamming transition has been intensely studied in recent years, more realistic frictional packings are less well understood. In frictionless sphere packings, the transition is predicted by a simple mean-field constraint counting argument, the isostaticity argument. For frictional packings, a modified constraint counting argument, which includes slipping contacts at the Coulomb threshold, has had limited success in accounting for the transition. We propose that the frictional jamming transition is not mean field and is triggered by the nucleation of unstable regions, which are themselves dynamical objects due to the Coulomb criterion. We create frictional packings using MD simulations and test for the presence and shape of rigid clusters with the pebble game to identify the partition of the packing into stable and unstable regions. To understand the dynamics of these unstable regions we follow perturbations at contacts crucial to the stability of the ``frictional house of cards.''

  8. Meshfree Modeling of Munitions Penetration in Soils

    DTIC Science & Technology

    2017-04-01

    discretization ...................... 8 Figure 2. Nodal smoothing domain for the modified stabilized nonconforming nodal integration...projectile ............................................................................................... 36 Figure 17. Discretization for the...List of Acronyms DEM: discrete element methods FEM: finite element methods MSNNI: modified stabilized nonconforming nodal integration RK

  9. Advances in HgCdTe APDs and LADAR Receivers

    NASA Technical Reports Server (NTRS)

    Bailey, Steven; McKeag, William; Wang, Jinxue; Jack, Michael; Amzajerdian, Farzin

    2010-01-01

    Raytheon is developing NIR sensor chip assemblies (SCAs) for scanning and staring 3D LADAR systems. High sensitivity is obtained by integrating high performance detectors with gain i.e. APDs with very low noise Readout Integrated Circuits. Unique aspects of these designs include: independent acquisition (non-gated) of pulse returns, multiple pulse returns with both time and intensity reported to enable full 3D reconstruction of the image. Recent breakthrough in device design has resulted in HgCdTe APDs operating at 300K with essentially no excess noise to gains in excess of 100, low NEP <1nW and GHz bandwidths and have demonstrated linear mode photon counting. SCAs utilizing these high performance APDs have been integrated and demonstrated excellent spatial and range resolution enabling detailed 3D imagery both at short range and long ranges. In this presentation we will review progress in high resolution scanning, staring and ultra-high sensitivity photon counting LADAR sensors.

  10. Advances in LADAR Components and Subsystems at Raytheon

    NASA Technical Reports Server (NTRS)

    Jack, Michael; Chapman, George; Edwards, John; McKeag, William; Veeder, Tricia; Wehner, Justin; Roberts, Tom; Robinson, Tom; Neisz, James; Andressen, Cliff; hide

    2012-01-01

    Raytheon is developing NIR sensor chip assemblies (SCAs) for scanning and staring 3D LADAR systems. High sensitivity is obtained by integrating high performance detectors with gain, i.e., APDs with very low noise Readout Integrated Circuits (ROICs). Unique aspects of these designs include: independent acquisition (non-gated) of pulse returns, multiple pulse returns with both time and intensity reported to enable full 3D reconstruction of the image. Recent breakthrough in device design has resulted in HgCdTe APDs operating at 300K with essentially no excess noise to gains in excess of 100, low NEP <1nW and GHz bandwidths and have demonstrated linear mode photon counting. SCAs utilizing these high performance APDs have been integrated and demonstrated excellent spatial and range resolution enabling detailed 3D imagery both at short range and long ranges. In the following we will review progress in real-time 3D LADAR imaging receiver products in three areas: (1) scanning 256 x 4 configuration for the Multi-Mode Sensor Seeker (MMSS) program and (2) staring 256 x 256 configuration for the Autonomous Landing and Hazard Avoidance Technology (ALHAT) lunar landing mission and (3) Photon-Counting SCAs which have demonstrated a dramatic reduction in dark count rate due to improved design, operation and processing.

  11. A new NIST primary standardization of 18F.

    PubMed

    Fitzgerald, R; Zimmerman, B E; Bergeron, D E; Cessna, J C; Pibida, L; Moreira, D S

    2014-02-01

    A new primary standardization of (18)F by NIST is reported. The standard is based on live-timed beta-gamma anticoincidence counting with confirmatory measurements by three other methods: (i) liquid scintillation (LS) counting using CIEMAT/NIST (3)H efficiency tracing; (ii) triple-to-double coincidence ratio (TDCR) counting; and (iii) NaI integral counting and HPGe γ-ray spectrometry. The results are reported as calibration factors for NIST-maintained ionization chambers (including some "dose calibrators"). The LS-based methods reveal evidence for cocktail instability for one LS cocktail. Using an ionization chamber to link this work with previous NIST results, the new value differs from the previous reports by about 4%, but appears to be in good agreement with the key comparison reference value (KCRV) of 2005. © 2013 Published by Elsevier Ltd.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manjunath, Naren; Samajdar, Rhine; Jain, Sudhir R., E-mail: srjain@barc.gov.in

    Recently, the nodal domain counts of planar, integrable billiards with Dirichlet boundary conditions were shown to satisfy certain difference equations in Samajdar and Jain (2014). The exact solutions of these equations give the number of domains explicitly. For complete generality, we demonstrate this novel formulation for three additional separable systems and thus extend the statement to all integrable billiards.

  13. Where Cultural Games Count: The Voices of Primary Classroom Teachers

    ERIC Educational Resources Information Center

    Nabie, Michael Johnson

    2015-01-01

    This study explored Ghanaian primary school teachers' values and challenges of integrating cultural games in teaching mathematics. Using an In-depth conversational interview, ten (10) certificated teachers' voices on the values and challenges of integrating games were examined. Thematic data analysis was applied to the qualitative data from the…

  14. Bibliometrics, Librarians, and Bibliograms

    ERIC Educational Resources Information Center

    White, Howard D.

    2016-01-01

    This paper sets forth an integrated way of introducing bibliometrics to relatively non-quantitative audiences, such as librarians and iSchool students. The integrative device is the bibliogram, a linguistic object consisting of a seed term and the terms that co-occur with it, ranked by their co-occurrence counts with the seed--a standard…

  15. Integration and task shifting for TB/HIV care and treatment in highly resource-scarce settings: one size may not fit all.

    PubMed

    Van Rie, Annelies; Patel, Monita R; Nana, Mbonze; Vanden Driessche, Koen; Tabala, Martine; Yotebieng, Marcel; Behets, Frieda

    2014-03-01

    A crucial question in managing HIV-infected patients with tuberculosis (TB) concerns when and how to initiate antiretroviral therapy (ART). The effectiveness of CD4-stratified ART initiation in a nurse-centered, integrated TB/HIV program at primary care in Kinshasa, Democratic Republic of Congo, was assessed. Prospective cohort study was conducted to assess the effect of CD4-stratified ART initiation by primary care nurses (513 TB patients, August 2007 to November 2009). ART was to be initiated at 1 month of TB treatment if CD4 count is <100 cells per cubic millimeter, at 2 months if CD4 count is 100-350 cells per cubic millimeter, and at the end of TB treatment after CD4 count reassessment if CD4 count is >350 cells per cubic millimeter. ART uptake and mortality were compared with a historical prospective cohort of 373 HIV-infected TB patients referred for ART to a centralized facility and 3577 HIV-negative TB patients (January 2006 to May 2007). ART uptake increased (17%-69%, P < 0.0001) and mortality during TB treatment decreased (20.1% vs 9.8%, P < 0.0003) after decentralized, nurse-initiated, CD4-stratified ART. Mortality among TB patients with CD4 count >100 cells per cubic millimeter was similar to that of HIV-negative TB patients (5.6% vs 6.3%, P = 0.65), but mortality among those with CD4 count <100 cells per cubic millimeter remained high (18.8%). Nurse-centered, CD4-stratified ART initiation at primary care level was effective in increasing timely ART uptake and reducing mortality among TB patients but may not be adequate to prevent mortality among those presenting with severe immunosuppression. Further research is needed to determine the optimal management at primary care level of TB patients with CD4 counts <100 cells per cubic millimeter.

  16. Recursive least squares background prediction of univariate syndromic surveillance data

    PubMed Central

    2009-01-01

    Background Surveillance of univariate syndromic data as a means of potential indicator of developing public health conditions has been used extensively. This paper aims to improve the performance of detecting outbreaks by using a background forecasting algorithm based on the adaptive recursive least squares method combined with a novel treatment of the Day of the Week effect. Methods Previous work by the first author has suggested that univariate recursive least squares analysis of syndromic data can be used to characterize the background upon which a prediction and detection component of a biosurvellance system may be built. An adaptive implementation is used to deal with data non-stationarity. In this paper we develop and implement the RLS method for background estimation of univariate data. The distinctly dissimilar distribution of data for different days of the week, however, can affect filter implementations adversely, and so a novel procedure based on linear transformations of the sorted values of the daily counts is introduced. Seven-days ahead daily predicted counts are used as background estimates. A signal injection procedure is used to examine the integrated algorithm's ability to detect synthetic anomalies in real syndromic time series. We compare the method to a baseline CDC forecasting algorithm known as the W2 method. Results We present detection results in the form of Receiver Operating Characteristic curve values for four different injected signal to noise ratios using 16 sets of syndromic data. We find improvements in the false alarm probabilities when compared to the baseline W2 background forecasts. Conclusion The current paper introduces a prediction approach for city-level biosurveillance data streams such as time series of outpatient clinic visits and sales of over-the-counter remedies. This approach uses RLS filters modified by a correction for the weekly patterns often seen in these data series, and a threshold detection algorithm from the residuals of the RLS forecasts. We compare the detection performance of this algorithm to the W2 method recently implemented at CDC. The modified RLS method gives consistently better sensitivity at multiple background alert rates, and we recommend that it should be considered for routine application in bio-surveillance systems. PMID:19149886

  17. Recursive least squares background prediction of univariate syndromic surveillance data.

    PubMed

    Najmi, Amir-Homayoon; Burkom, Howard

    2009-01-16

    Surveillance of univariate syndromic data as a means of potential indicator of developing public health conditions has been used extensively. This paper aims to improve the performance of detecting outbreaks by using a background forecasting algorithm based on the adaptive recursive least squares method combined with a novel treatment of the Day of the Week effect. Previous work by the first author has suggested that univariate recursive least squares analysis of syndromic data can be used to characterize the background upon which a prediction and detection component of a biosurvellance system may be built. An adaptive implementation is used to deal with data non-stationarity. In this paper we develop and implement the RLS method for background estimation of univariate data. The distinctly dissimilar distribution of data for different days of the week, however, can affect filter implementations adversely, and so a novel procedure based on linear transformations of the sorted values of the daily counts is introduced. Seven-days ahead daily predicted counts are used as background estimates. A signal injection procedure is used to examine the integrated algorithm's ability to detect synthetic anomalies in real syndromic time series. We compare the method to a baseline CDC forecasting algorithm known as the W2 method. We present detection results in the form of Receiver Operating Characteristic curve values for four different injected signal to noise ratios using 16 sets of syndromic data. We find improvements in the false alarm probabilities when compared to the baseline W2 background forecasts. The current paper introduces a prediction approach for city-level biosurveillance data streams such as time series of outpatient clinic visits and sales of over-the-counter remedies. This approach uses RLS filters modified by a correction for the weekly patterns often seen in these data series, and a threshold detection algorithm from the residuals of the RLS forecasts. We compare the detection performance of this algorithm to the W2 method recently implemented at CDC. The modified RLS method gives consistently better sensitivity at multiple background alert rates, and we recommend that it should be considered for routine application in bio-surveillance systems.

  18. Gene editing of CCR5 in autologous CD4 T cells of persons infected with HIV.

    PubMed

    Tebas, Pablo; Stein, David; Tang, Winson W; Frank, Ian; Wang, Shelley Q; Lee, Gary; Spratt, S Kaye; Surosky, Richard T; Giedlin, Martin A; Nichol, Geoff; Holmes, Michael C; Gregory, Philip D; Ando, Dale G; Kalos, Michael; Collman, Ronald G; Binder-Scholl, Gwendolyn; Plesa, Gabriela; Hwang, Wei-Ting; Levine, Bruce L; June, Carl H

    2014-03-06

    CCR5 is the major coreceptor for human immunodeficiency virus (HIV). We investigated whether site-specific modification of the gene ("gene editing")--in this case, the infusion of autologous CD4 T cells in which the CCR5 gene was rendered permanently dysfunctional by a zinc-finger nuclease (ZFN)--is safe. We enrolled 12 patients in an open-label, nonrandomized, uncontrolled study of a single dose of ZFN-modified autologous CD4 T cells. The patients had chronic aviremic HIV infection while they were receiving highly active antiretroviral therapy. Six of them underwent an interruption in antiretroviral treatment 4 weeks after the infusion of 10 billion autologous CD4 T cells, 11 to 28% of which were genetically modified with the ZFN. The primary outcome was safety as assessed by treatment-related adverse events. Secondary outcomes included measures of immune reconstitution and HIV resistance. One serious adverse event was associated with infusion of the ZFN-modified autologous CD4 T cells and was attributed to a transfusion reaction. The median CD4 T-cell count was 1517 per cubic millimeter at week 1, a significant increase from the preinfusion count of 448 per cubic millimeter (P<0.001). The median concentration of CCR5-modified CD4 T cells at 1 week was 250 cells per cubic millimeter. This constituted 8.8% of circulating peripheral-blood mononuclear cells and 13.9% of circulating CD4 T cells. Modified cells had an estimated mean half-life of 48 weeks. During treatment interruption and the resultant viremia, the decline in circulating CCR5-modified cells (-1.81 cells per day) was significantly less than the decline in unmodified cells (-7.25 cells per day) (P=0.02). HIV RNA became undetectable in one of four patients who could be evaluated. The blood level of HIV DNA decreased in most patients. CCR5-modified autologous CD4 T-cell infusions are safe within the limits of this study. (Funded by the National Institute of Allergy and Infectious Diseases and others; ClinicalTrials.gov number, NCT00842634.).

  19. Receptor binding assay for paralytic shellfish poisoning toxins: optimization and interlaboratory comparison.

    PubMed

    Ruberu, Shryamalie R; Liu, Yun-Gang; Wong, Carolyn T; Perera, S Kusum; Langlois, Gregg W; Doucette, Gregory J; Powell, Christine L

    2003-01-01

    A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California Department of Health Services, which uses a Packard TopCount scintillation counter. Due to differences in the detector arrangement between these 2 counters, markedly different counting efficiencies were exhibited, requiring optimization of the RBA protocol for the TopCount instrument. Precision, accuracy, and sensitivity [limit of detection = 0.2 microg saxitoxin (STX) equiv/100 g shellfish tissue] of the modified protocol were equivalent to those of the original protocol. The RBA robustness and adaptability were demonstrated by an interlaboratory study, in which STX concentrations in shellfish generated by the TopCount were consistent with MicroBeta-derived values. Comparison of STX reference standards obtained from the U.S. Food and Drug Administration and the National Research Council, Canada, showed no observable differences. This study confirms the RBA's value as a rapid, high throughput screen prior to testing by the conventional mouse bioassay (MBA) and its suitability for providing an early warning of increasing PSP toxicity when toxin levels are below the MBA limit of detection.

  20. A loop-counting method for covariate-corrected low-rank biclustering of gene-expression and genome-wide association study data.

    PubMed

    Rangan, Aaditya V; McGrouther, Caroline C; Kelsoe, John; Schork, Nicholas; Stahl, Eli; Zhu, Qian; Krishnan, Arjun; Yao, Vicky; Troyanskaya, Olga; Bilaloglu, Seda; Raghavan, Preeti; Bergen, Sarah; Jureus, Anders; Landen, Mikael

    2018-05-14

    A common goal in data-analysis is to sift through a large data-matrix and detect any significant submatrices (i.e., biclusters) that have a low numerical rank. We present a simple algorithm for tackling this biclustering problem. Our algorithm accumulates information about 2-by-2 submatrices (i.e., 'loops') within the data-matrix, and focuses on rows and columns of the data-matrix that participate in an abundance of low-rank loops. We demonstrate, through analysis and numerical-experiments, that this loop-counting method performs well in a variety of scenarios, outperforming simple spectral methods in many situations of interest. Another important feature of our method is that it can easily be modified to account for aspects of experimental design which commonly arise in practice. For example, our algorithm can be modified to correct for controls, categorical- and continuous-covariates, as well as sparsity within the data. We demonstrate these practical features with two examples; the first drawn from gene-expression analysis and the second drawn from a much larger genome-wide-association-study (GWAS).

  1. Predicting bacterial growth in raw, salted, and cooked chicken breast fillets during storage.

    PubMed

    Galarz, Liane Aldrighi; Fonseca, Gustavo Graciano; Prentice, Carlos

    2016-09-01

    Growth curves were evaluated for aerobic mesophilic and psychrotrophic bacteria, Pseudomonas spp. and Staphylococcus spp., grown in raw, salted, and cooked chicken breast at 2, 4, 7, 10, 15, and 20 ℃, respectively, using the modified Gompertz and modified logistic models. Shelf life was determined based on microbiological counts and sensory analysis. Temperature increase reduced the shelf life, which varied from 10 to 26 days at 2 ℃, from nine to 21 days at 4 ℃, from six to 12 days at 7 ℃, from four to eight days at 10 ℃, from two to four days at 15 ℃, and from one to two days at 20 ℃. In most cases, cooked chicken breast showed the highest microbial count, followed by raw breast and lastly salted breast. The data obtained here were useful for the generation of mathematical models and parameters. The models presented high correlation and can be used for predictive purposes in the poultry meat supply chain. © The Author(s) 2015.

  2. [Automated hematology analysers and spurious counts Part 3. Haemoglobin, red blood cells, cell count and indices, reticulocytes].

    PubMed

    Godon, Alban; Genevieve, Franck; Marteau-Tessier, Anne; Zandecki, Marc

    2012-01-01

    Several situations lead to abnormal haemoglobin measurement or to abnormal red blood cells (RBC) counts, including hyperlipemias, agglutinins and cryoglobulins, haemolysis, or elevated white blood cells (WBC) counts. Mean (red) cell volume may be also subject to spurious determination, because of agglutinins (mainly cold), high blood glucose level, natremia, anticoagulants in excess and at times technological considerations. Abnormality related to one measured parameter eventually leads to abnormal calculated RBC indices: mean cell haemoglobin content is certainly the most important RBC parameter to consider, maybe as important as flags generated by the haematology analysers (HA) themselves. In many circumstances, several of the measured parameters from cell blood counts (CBC) may be altered, and the discovery of a spurious change on one parameter frequently means that the validity of other parameters should be considered. Sensitive flags allow now the identification of several spurious counts, but only the most sophisticated HA have optimal flagging, and simpler ones, especially those without any WBC differential scattergram, do not share the same capacity to detect abnormal results. Reticulocytes are integrated into the CBC in many HA, and several situations may lead to abnormal counts, including abnormal gating, interference with intraerythrocytic particles, erythroblastosis or high WBC counts.

  3. Electrostatically defined silicon quantum dots with counted antimony donor implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, M., E-mail: msingh@sandia.gov; Luhman, D. R.; Lilly, M. P.

    2016-02-08

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. In this work, a focused ion beam is used to implant antimony donors in 100 nm × 150 nm windows straddling quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of donors implanted can be counted to a precision of a single ion. In low-temperature transport measurements, regular Coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization are also observed in devices with counted donor implants.

  4. Electrostatically defined silicon quantum dots with counted antimony donor implants

    NASA Astrophysics Data System (ADS)

    Singh, M.; Pacheco, J. L.; Perry, D.; Garratt, E.; Ten Eyck, G.; Bishop, N. C.; Wendt, J. R.; Manginell, R. P.; Dominguez, J.; Pluym, T.; Luhman, D. R.; Bielejec, E.; Lilly, M. P.; Carroll, M. S.

    2016-02-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. In this work, a focused ion beam is used to implant antimony donors in 100 nm × 150 nm windows straddling quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of donors implanted can be counted to a precision of a single ion. In low-temperature transport measurements, regular Coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization are also observed in devices with counted donor implants.

  5. Reduction of Salmonella on chicken breast fillets stored under aerobic or modified atmosphere packaging by the application of lytic bacteriophage preparation SalmoFreshTM.

    PubMed

    Sukumaran, Anuraj T; Nannapaneni, Rama; Kiess, Aaron; Sharma, Chander Shekhar

    2016-03-01

    The present study evaluated the efficacy of recently approved Salmonella lytic bacteriophage preparation (SalmoFresh™) in reducing Salmonella on chicken breast fillets, as a surface and dip application. The effectiveness of phage in combination with modified atmosphere packaging (MAP) and the ability of phage preparation in reducing Salmonella on chicken breast fillets at room temperature was also evaluated. Chicken breast fillets inoculated with a cocktail of Salmonella Typhimurium, S. Heidelberg, and S. Enteritidis were treated with bacteriophage (10(9) PFU/mL) as either a dip or surface treatment. The dip-treated samples were stored at 4°C aerobically and the surface-treated samples were stored under aerobic and MAP conditions (95% CO2/5% O2) at 4°C for 7 d. Immersion of Salmonella-inoculated chicken breast fillets in bacteriophage solution reduced Salmonella (P < 0.05) by 0.7 and 0.9 log CFU/g on d 0 and d 1 of storage, respectively. Surface treatment with phage significantly (P < 0.05) reduced Salmonella by 0.8, 0.8, and 1 log CFU/g on d 0, 1, and 7 of storage, respectively, under aerobic conditions. Higher reductions in Salmonella counts were achieved on chicken breast fillets when the samples were surface treated with phage and stored under MAP conditions. The Salmonella counts were reduced by 1.2, 1.1, and 1.2 log CFU/g on d 0, 1, and 7 of storage, respectively. Bacteriophage surface application on chicken breast fillets stored at room temperature reduced the Salmonella counts by 0.8, 0.9, and 0.4 log CFU/g after 0, 4, and 8 h, respectively, compared to the untreated positive control. These findings indicate that lytic phage preparation was effective in reducing Salmonella on chicken breast fillets stored under aerobic and modified atmosphere conditions. © 2015 Poultry Science Association Inc.

  6. The 2-24 μm source counts from the AKARI North Ecliptic Pole survey

    NASA Astrophysics Data System (ADS)

    Murata, K.; Pearson, C. P.; Goto, T.; Kim, S. J.; Matsuhara, H.; Wada, T.

    2014-11-01

    We present herein galaxy number counts of the nine bands in the 2-24 μm range on the basis of the AKARI North Ecliptic Pole (NEP) surveys. The number counts are derived from NEP-deep and NEP-wide surveys, which cover areas of 0.5 and 5.8 deg2, respectively. To produce reliable number counts, the sources were extracted from recently updated images. Completeness and difference between observed and intrinsic magnitudes were corrected by Monte Carlo simulation. Stellar counts were subtracted by using the stellar fraction estimated from optical data. The resultant source counts are given down to the 80 per cent completeness limit; 0.18, 0.16, 0.10, 0.05, 0.06, 0.10, 0.15, 0.16 and 0.44 mJy in the 2.4, 3.2, 4.1, 7, 9, 11, 15, 18 and 24 μm bands, respectively. On the bright side of all bands, the count distribution is flat, consistent with the Euclidean universe, while on the faint side, the counts deviate, suggesting that the galaxy population of the distant universe is evolving. These results are generally consistent with previous galaxy counts in similar wavebands. We also compare our counts with evolutionary models and find them in good agreement. By integrating the models down to the 80 per cent completeness limits, we calculate that the AKARI NEP survey revolves 20-50 per cent of the cosmic infrared background, depending on the wavebands.

  7. GATE Monte Carlo simulations for variations of an integrated PET/MR hybrid imaging system based on the Biograph mMR model

    NASA Astrophysics Data System (ADS)

    Aklan, B.; Jakoby, B. W.; Watson, C. C.; Braun, H.; Ritt, P.; Quick, H. H.

    2015-06-01

    A simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop an accurate Monte Carlo (MC) simulation of a fully integrated 3T PET/MR hybrid imaging system (Siemens Biograph mMR). The PET/MR components of the Biograph mMR were simulated in order to allow a detailed study of variations of the system design on the PET performance, which are not easy to access and measure on a real PET/MR system. The 3T static magnetic field of the MR system was taken into account in all Monte Carlo simulations. The validation of the MC model was carried out against actual measurements performed on the PET/MR system by following the NEMA (National Electrical Manufacturers Association) NU 2-2007 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction, and count rate capability. The validated system model was then used for two different applications. The first application focused on investigating the effect of an extension of the PET field-of-view on the PET performance of the PET/MR system. The second application deals with simulating a modified system timing resolution and coincidence time window of the PET detector electronics in order to simulate time-of-flight (TOF) PET detection. A dedicated phantom was modeled to investigate the impact of TOF on overall PET image quality. Simulation results showed that the overall divergence between simulated and measured data was found to be less than 10%. Varying the detector geometry showed that the system sensitivity and noise equivalent count rate of the PET/MR system increased progressively with an increasing number of axial detector block rings, as to be expected. TOF-based PET reconstructions of the modeled phantom showed an improvement in signal-to-noise ratio and image contrast to the conventional non-TOF PET reconstructions. In conclusion, the validated MC simulation model of an integrated PET/MR system with an overall accuracy error of less than 10% can now be used for further MC simulation applications such as development of hardware components as well as for testing of new PET/MR software algorithms, such as assessment of point-spread function-based reconstruction algorithms.

  8. Can Appropriate Systemic Treatment Help Protect the Cornea in Patients With Rheumatoid Arthritis? A Multidisciplinary Approach to Autoimmune Ocular Involvement.

    PubMed

    Amador-Patarroyo, Manuel J; Jalil-Florencia, Emilio; Otero-Marquez, Oscar; Molano-Gonzalez, Nicolás; Mantilla, Ruben D; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel; Barraquer-Coll, Carmen

    2018-02-01

    To correlate rheumatologic with ophthalmic and laboratory findings in patients with rheumatoid arthritis (RA) to identify what effect these have on development of ocular disease. This is a cross-sectional study of 172 eyes of 86 patients with RA. Patients were examined by a group of rheumatologists. Sociodemographic, clinical, and laboratory data were collected. All patients underwent complete ophthalmologic examination including corneal topography and endothelial cell count. There was no significant correlation between RA-negative prognostic indicators (NPIs) and pathologic corneal findings. Patients using disease-modifying antirheumatic drugs (DMARDs) and antimalarial drugs had greater corneal volumes (mean difference 8.51 mm, 90% confidence interval [CI], 3.98-13.04, P = 0.004; and 2.24, 90% CI, 0.32-4.54, P = 0.048, respectively). Patients using azathioprine had lower endothelial cell counts compared with those using other drugs (mean difference 180 cells/mm, 90% CI, 69-291, P = 0.008). Patients using biologic DMARDs had better tear osmolarity values (between 280 and 300 mOsm/L) than patients not using them (mean difference 14.3 mOsm/L, P = 0.022). There was no correlation between NPIs of RA and positive keratoconus screening indices (Spearman correlation OD -0.013, P = 0.91; OS -0.033, P = 0.76). There was no clear correlation between RA-NPIs and pathologic corneal findings in our study. DMARDs treatment may help maintain corneal integrity in our patients and prevented collagenolytic manifestations of RA. Other medications such as azathioprine should be used carefully, as endothelial damage may potentially occur.

  9. Counting local integrals of motion in disordered spinless-fermion and Hubbard chains

    NASA Astrophysics Data System (ADS)

    Mierzejewski, Marcin; Kozarzewski, Maciej; Prelovšek, Peter

    2018-02-01

    We develop a procedure which systematically generates all conserved operators in the disordered models of interacting fermions. Among these operators, we identify and count the independent and local integrals of motion (LIOM), which represent the hallmark of the many-body localization (MBL). The method is tested first on the prototype disordered chain of interacting spinless fermions. As expected for full MBL, we find for large enough disorder NM=2M-1 independent and quasilocal LIOM with support on M consecutive sites. On the other hand, the study of the disordered Hubbard chain reveals that 3M-1

  10. Protective isolation in single-bed rooms: studies in a modified hospital ward

    PubMed Central

    Ayliffe, G. A. J.; Collins, B. J.; Lowbury, E. J. L.; Wall, Mary

    1971-01-01

    Studies were made in a modified hospital ward containing 19 beds, 14 of them in the open ward, one in a window-ventilated side-room, two in rooms with partial-recirculation ventilators giving 7-10 air changes per hour, and two in self-contained isolation suites with plenum ventilation (20 air changes per hour), ultra-violet (UV) barriers at doorways and airlocks. Preliminary tests with aerosols of tracer bacteria showed that few bacteria entered the plenum or recirculation-ventilated rooms. Bacteria released inside mechanically ventilated cubicles escaped into the corridor, but this transfer was reduced by the presence of an airlock. UV barriers at the entrance to the airlock and the cubicle reduced the transfer of bacteria from cubicle to corridor. During a period of 4 years while the ward was in use for surgical and gynaecological patients, the incidence of post-operative sepsis and colonization of wounds by multiple-resistant Staphylococcus aureus was lower (though not significantly lower) in the plenum-ventilated rooms than in the open ward, the recirculator-ventilated cubicles and the window-ventilated cubicles. Nasal acquisition of multiple-resistant Staph. aureus was significantly less common in the plenum-ventilated than in the recirculator-ventilated cubicles and in the other areas. Mean counts of bacteria on settle-plates were significantly lower in the plenum-ventilated cubicles than in the other areas; mean settle-plate counts in the recirculator-ventilated cubicles were significantly lower than in the open ward and in the window-ventilated side-room; similar results were shown by slit-sampling of air. Mean settle-plate counts were significantly lower in all areas when the ward was occupied by female patients. Staph. aureus was rarely carried by air from plenum-ventilated or other cubicles to the open ward, or from the open ward to the cubicles; though staphylococci were transferred from one floor area to another, they did not appear to be redispersed into the air in sufficient numbers to infect the patients. Ultra-violet irradiation caused a significant reduction in the total and staphylococcal counts from the floors of airlocks, and a significant reduction of total counts in the air. PMID:5289715

  11. Keeping the Dogs in the Fight: What Combatant Commanders Need to Know about MWDs

    DTIC Science & Technology

    2013-05-20

    Manhattan Project that Bombed,” Public Integrity, Last modified August 2011, http://www.publicintegrity.org/2011/03/27/3799/jieddo- manhattan - project -bombed...Carey, Peter. “JIEDDO: The Manhattan Project that Bombed.” Public Integrity. Last modified August 2011. http://www.publicintegrity.org/2011/03/27...3799/jieddo- manhattan - project -bombed. Community Marines. “MCO 5580.2B.” Last modified August 2008. http://community.marines.mil/news

  12. General pulsed-field gradient signal attenuation expression based on a fractional integral modified-Bloch equation

    NASA Astrophysics Data System (ADS)

    Lin, Guoxing

    2018-10-01

    Anomalous diffusion has been investigated in many polymer and biological systems. The analysis of PFG anomalous diffusion relies on the ability to obtain the signal attenuation expression. However, the general analytical PFG signal attenuation expression based on the fractional derivative has not been previously reported. Additionally, the reported modified-Bloch equations for PFG anomalous diffusion in the literature yielded different results due to their different forms. Here, a new integral type modified-Bloch equation based on the fractional derivative for PFG anomalous diffusion is proposed, which is significantly different from the conventional differential type modified-Bloch equation. The merit of the integral type modified-Bloch equation is that the original properties of the contributions from linear or nonlinear processes remain unchanged at the instant of the combination. From the modified-Bloch equation, the general solutions are derived, which includes the finite gradient pulse width (FGPW) effect. The numerical evaluation of these PFG signal attenuation expressions can be obtained either by the Adomian decomposition, or a direct integration method that is fast and practicable. The theoretical results agree with the continuous-time random walk (CTRW) simulations performed in this paper. Additionally, the relaxation effect in PFG anomalous diffusion is found to be different from that in PFG normal diffusion. The new modified-Bloch equations and their solutions provide a fundamental tool to analyze PFG anomalous diffusion in nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI).

  13. A whole-system approach to x-ray spectroscopy in cargo inspection systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langeveld, Willem G. J.; Gozani, Tsahi; Ryge, Peter

    The bremsstrahlung x-ray spectrum used in high-energy, high-intensity x-ray cargo inspection systems is attenuated and modified by the materials in the cargo in a Z-dependent way. Therefore, spectroscopy of the detected x rays yields information about the Z of the x-rayed cargo material. It has previously been shown that such ZSpectroscopy (Z-SPEC) is possible under certain circumstances. A statistical approach, Z-SCAN (Z-determination by Statistical Count-rate ANalysis), has also been shown to be effective, and it can be used either by itself or in conjunction with Z-SPEC when the x-ray count rate is too high for individual x-ray spectroscopy. Both techniquesmore » require fast x-ray detectors and fast digitization electronics. It is desirable (and possible) to combine all techniques, including x-ray imaging of the cargo, in a single detector array, to reduce costs, weight, and overall complexity. In this paper, we take a whole-system approach to x-ray spectroscopy in x-ray cargo inspection systems, and show how the various parts interact with one another. Faster detectors and read-out electronics are beneficial for both techniques. A higher duty-factor x-ray source allows lower instantaneous count rates at the same overall x-ray intensity, improving the range of applicability of Z-SPEC in particular. Using an intensity-modulated advanced x-ray source (IMAXS) allows reducing the x-ray count rate for cargoes with higher transmission, and a stacked-detector approach may help material discrimination for the lowest attenuations. Image processing and segmentation allow derivation of results for entire objects, and subtraction of backgrounds. We discuss R and D performed under a number of different programs, showing progress made in each of the interacting subsystems. We discuss results of studies into faster scintillation detectors, including ZnO, BaF{sub 2} and PbWO{sub 4}, as well as suitable photo-detectors, read-out and digitization electronics. We discuss high-duty-factor linear-accelerator x-ray sources and their associated requirements, and how such sources improve spectroscopic techniques. We further discuss how image processing techniques help in correcting for backgrounds and overlapping materials. In sum, we present an integrated picture of how to optimize a cargo inspection system for x-ray spectroscopy.« less

  14. Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

    NASA Technical Reports Server (NTRS)

    Smith, S. J.; Adams, J. S.; Bandler, S. R.; Betancourt-Martinez, G. L.; Chervenak, J. A.; Chiao, M. P.; Eckart, M. E.; Finkbeiner, F. M.; Kelley, R. L.; Kilbourne, C. A.; hide

    2016-01-01

    The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

  15. Ozone and Interdisciplinary Science Teaching--Learning to Address the Things That Count Most.

    ERIC Educational Resources Information Center

    Hobson, Art

    1993-01-01

    Presents the ozone depletion story as an excellent case study for the integration of science-related social issues into the college science curriculum. Describes the history of ozone depletion and efforts to remedy the problem. Provides a lecture outline on ozone depletion. Discusses integrating other science-related interdisciplinary topics in…

  16. Human milk galectin-3 binding protein and breast-feeding-associated HIV transmission.

    PubMed

    Chan, Christina S; Kim, Hae-Young; Autran, Chloe; Kim, Jae H; Sinkala, Moses; Kankasa, Chipepo; Mwiya, Mwiya; Thea, Donald M; Aldrovandi, Grace M; Kuhn, Louise; Bode, Lars

    2013-12-01

    Analysis of milk from 247 HIV-infected Zambian mothers showed that galectin-3 binding protein concentrations were significantly higher among HIV-infected mothers who transmitted HIV through breast-feeding (6.51 ± 2.12 μg/mL) than among nontransmitters but were also correlated with higher milk and plasma HIV RNA copies/mL and lower CD4+ cell counts. The association between galectin-3 binding protein and postnatal transmission was attenuated after adjustment for milk and plasma HIV load and CD4+ cell counts. This suggests that although milk galectin-3 binding protein is a marker of advanced maternal disease, it does not independently modify transmission risk.

  17. Alkali Halide Microstructured Optical Fiber for X-Ray Detection

    NASA Technical Reports Server (NTRS)

    DeHaven, S. L.; Wincheski, R. A.; Albin, S.

    2014-01-01

    Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. The results and associated materials difference are discussed.

  18. Remodeling census population with spatial information from Landsat TM imagery

    USGS Publications Warehouse

    Yuan, Y.; Smith, R.M.; Limp, W.F.

    1997-01-01

    In geographic information systems (GIS) studies there has been some difficulty integrating socioeconomic and physiogeographic data. One important type of socioeconomic data, census data, offers a wide range of socioeconomic information, but is aggregated within arbitrary enumeration districts (EDs). Values reflect either raw counts or, when standardized, the mean densities in the EDs. On the other hand, remote sensing imagery, an important type of physiogeographic data, provides large quantities of information with more spatial details than census data. Based on the dasymetric mapping principle, this study applies multivariable regression to examine the correlation between population counts from census and land cover types. The land cover map is classified from LandSat TM imagery. The correlation is high. Census population counts are remodeled to a GIS raster layer based on the discovered correlations coupled with scaling techniques, which offset influences from other than land cover types. The GIS raster layer depicts the population distribution with much more spatial detail than census data offer. The resulting GIS raster layer is ready to be analyzed or integrated with other GIS data. ?? 1998 Elsevier Science Ltd. All rights reserved.

  19. Counted Sb donors in Si quantum dots

    NASA Astrophysics Data System (ADS)

    Singh, Meenakshi; Pacheco, Jose; Bielejec, Edward; Perry, Daniel; Ten Eyck, Gregory; Bishop, Nathaniel; Wendt, Joel; Luhman, Dwight; Carroll, Malcolm; Lilly, Michael

    2015-03-01

    Deterministic control over the location and number of donors is critical for donor spin qubits in semiconductor based quantum computing. We have developed techniques using a focused ion beam and a diode detector integrated next to a silicon MOS single electron transistor to gain such control. With the diode detector operating in linear mode, the numbers of ions implanted have been counted and single ion implants have been detected. Poisson statistics in the number of ions implanted have been observed. Transport measurements performed on samples with counted number of implants have been performed and regular coulomb blockade and charge offsets observed. The capacitances to various gates are found to be in agreement with QCAD simulations for an electrostatically defined dot. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. The work was supported by Sandia National Laboratories Directed Research and Development Program. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  20. Integrated Arrival and Departure Schedule Optimization Under Uncertainty

    NASA Technical Reports Server (NTRS)

    Xue, Min; Zelinski, Shannon

    2014-01-01

    In terminal airspace, integrating arrivals and departures with shared waypoints provides the potential of improving operational efficiency by allowing direct routes when possible. Incorporating stochastic evaluation as a post-analysis process of deterministic optimization, and imposing a safety buffer in deterministic optimization, are two ways to learn and alleviate the impact of uncertainty and to avoid unexpected outcomes. This work presents a third and direct way to take uncertainty into consideration during the optimization. The impact of uncertainty was incorporated into cost evaluations when searching for the optimal solutions. The controller intervention count was computed using a heuristic model and served as another stochastic cost besides total delay. Costs under uncertainty were evaluated using Monte Carlo simulations. The Pareto fronts that contain a set of solutions were identified and the trade-off between delays and controller intervention count was shown. Solutions that shared similar delays but had different intervention counts were investigated. The results showed that optimization under uncertainty could identify compromise solutions on Pareto fonts, which is better than deterministic optimization with extra safety buffers. It helps decision-makers reduce controller intervention while achieving low delays.

  1. Counting Dots.

    ERIC Educational Resources Information Center

    Repine, Tom; Hemler, Deb; Lane, Duane

    2003-01-01

    Presents a problem-solving investigation on coal mining that integrates science and mathematics with geology. Engages students in a scenario in which they play the roles of geologists and mining engineers. (NB)

  2. Urban and regional land use analysis: CARETS and census cities experiment package

    NASA Technical Reports Server (NTRS)

    Alexander, R. (Principal Investigator); Lins, H. F., Jr.; Gallagher, D. B.

    1975-01-01

    The author has identified the following significant results. Temperatures in degrees Celsius were derived from PCM counts using the Pease's modified gray window technique. The Outcalt simulator was setup on the USGS computer. The input data to the model are basically meteorological and geographical in nature. The output data is presented in three matrices.

  3. Professional Learning for Teaching Assistants and Its Effect on Classroom Roles

    ERIC Educational Resources Information Center

    Hurst, Chris; Sparrow, Len

    2012-01-01

    The Swan Valley Cluster of schools for the Make It Count project identified the professional learning of teachers and teaching assistants as a key factor in improving numeracy outcomes for urban Indigenous children. Initial training for assistants began in late 2010 and took the form of workshops based on a modified First Steps in Mathematics…

  4. The predictive value of noninvasive serum markers of liver fibrosis in patients with chronic hepatitis C.

    PubMed

    Gökcan, Hale; Kuzu, Ufuk Barış; Öztaş, Erkin; Saygılı, Fatih; Öztuna, Derya; Suna, Nuretdin; Tenlik, İlyas; Akdoğan, Meral; Kaçar, Sabite; Kılıç, Zeki Mesut Yalın; Kayaçetin, Ertuğrul

    2016-03-01

    This study aims to show the predictive value of noninvasive serum markers on the hepatic fibrosis level. This cross sectional study involves 120 patients with chronic hepatitis C. The noninvasive markers used were as follows: age-platelet index (AP index), cirrhosis discriminant score (CDS), aspartate aminotransferase (AST)-alanine aminotransferase (ALT) ratio (AAR), fibrosis-4 (FIB-4) index, AST-platelet ratio index (APRI), Goteborg University Cirrhosis Index (GUCI), FibroQ, King's score, platelet count. Concurrent liver biopsies were evaluated using the modified Ishak and Knodell scoring systems. In accordance with the Knodell scores, F3-F4 scores were defined as "severe fibrosis," and the modified Ishak scores stage of ≥3 (F3-F6) were defined as "clinically significant fibrosis." Receiver Operating Characteristic (ROC) curve analyses were carried out to compare the noninvasive markers with hepatic fibrosis level. Mean age of the patients was 51.7±11.6. A total of 10 patients (8.3%) with Knodell scores and 24 patients (20%) with modified Ishak scores were evaluated to have ≥F3 hepatic fibrosis. ROC analyses with the Knodell and modified Ishak scores were as follows: AP index=0.61-0.57, CDS=0.66-0.55, AAR=0.60-0.49, FIB-4=0.70-0.68, APRI=0.67-0.72, GUCI=0.66-0.72, FibroQ=0.64-0.54, King's score=0.68-0.54, platelet count=0.61-0.55. We found that APRI, FIB-4, King's score, and GUCI can be used to determination patients with mild fibrosis with a high negative predictive value and in the differentiation of severe/significant fibrosis from mild to moderate fibrosis.

  5. Detector motion method to increase spatial resolution in photon-counting detectors

    NASA Astrophysics Data System (ADS)

    Lee, Daehee; Park, Kyeongjin; Lim, Kyung Taek; Cho, Gyuseong

    2017-03-01

    Medical imaging requires high spatial resolution of an image to identify fine lesions. Photon-counting detectors in medical imaging have recently been rapidly replacing energy-integrating detectors due to the former`s high spatial resolution, high efficiency and low noise. Spatial resolution in a photon counting image is determined by the pixel size. Therefore, the smaller the pixel size, the higher the spatial resolution that can be obtained in an image. However, detector redesigning is required to reduce pixel size, and an expensive fine process is required to integrate a signal processing unit with reduced pixel size. Furthermore, as the pixel size decreases, charge sharing severely deteriorates spatial resolution. To increase spatial resolution, we propose a detector motion method using a large pixel detector that is less affected by charge sharing. To verify the proposed method, we utilized a UNO-XRI photon-counting detector (1-mm CdTe, Timepix chip) at the maximum X-ray tube voltage of 80 kVp. A similar spatial resolution of a 55- μm-pixel image was achieved by application of the proposed method to a 110- μm-pixel detector with a higher signal-to-noise ratio. The proposed method could be a way to increase spatial resolution without a pixel redesign when pixels severely suffer from charge sharing as pixel size is reduced.

  6. Photon counting detector for the personal radiography inspection system "SIBSCAN"

    NASA Astrophysics Data System (ADS)

    Babichev, E. A.; Baru, S. E.; Grigoriev, D. N.; Leonov, V. V.; Oleynikov, V. P.; Porosev, V. V.; Savinov, G. A.

    2017-02-01

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator - SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  7. Survey of predators and sampling method comparison in sweet corn.

    PubMed

    Musser, Fred R; Nyrop, Jan P; Shelton, Anthony M

    2004-02-01

    Natural predation is an important component of integrated pest management that is often overlooked because it is difficult to quantify and perceived to be unreliable. To begin incorporating natural predation into sweet corn, Zea mays L., pest management, a predator survey was conducted and then three sampling methods were compared for their ability to accurately monitor the most abundant predators. A predator survey on sweet corn foliage in New York between 1999 and 2001 identified 13 species. Orius insidiosus (Say), Coleomegilla maculata (De Geer), and Harmonia axyridis (Pallas) were the most numerous predators in all years. To determine the best method for sampling adult and immature stages of these predators, comparisons were made among nondestructive field counts, destructive counts, and yellow sticky cards. Field counts were correlated with destructive counts for all populations, but field counts of small insects were biased. Sticky cards underrepresented immature populations. Yellow sticky cards were more attractive to C. maculata adults than H. axyridis adults, especially before pollen shed, making coccinellid population estimates based on sticky cards unreliable. Field counts were the most precise method for monitoring adult and immature stages of the three major predators. Future research on predicting predation of pests in sweet corn should be based on field counts of predators because these counts are accurate, have no associated supply costs, and can be made quickly.

  8. The contribution of simple random sampling to observed variations in faecal egg counts.

    PubMed

    Torgerson, Paul R; Paul, Michaela; Lewis, Fraser I

    2012-09-10

    It has been over 100 years since the classical paper published by Gosset in 1907, under the pseudonym "Student", demonstrated that yeast cells suspended in a fluid and measured by a haemocytometer conformed to a Poisson process. Similarly parasite eggs in a faecal suspension also conform to a Poisson process. Despite this there are common misconceptions how to analyse or interpret observations from the McMaster or similar quantitative parasitic diagnostic techniques, widely used for evaluating parasite eggs in faeces. The McMaster technique can easily be shown from a theoretical perspective to give variable results that inevitably arise from the random distribution of parasite eggs in a well mixed faecal sample. The Poisson processes that lead to this variability are described and illustrative examples of the potentially large confidence intervals that can arise from observed faecal eggs counts that are calculated from the observations on a McMaster slide. Attempts to modify the McMaster technique, or indeed other quantitative techniques, to ensure uniform egg counts are doomed to failure and belie ignorance of Poisson processes. A simple method to immediately identify excess variation/poor sampling from replicate counts is provided. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Use of a continuous culture fermentation system to investigate the effect of GanedenBC30 (Bacillus coagulans GBI-30, 6086) supplementation on pathogen survival in the human gut microbiota.

    PubMed

    Honda, Harue; Gibson, Glenn R; Farmer, Sean; Keller, David; McCartney, Anne L

    2011-02-01

    Single-stage continuous fermentation systems were employed to examine the effects of GanedenBC(30) supplementation on the human gastrointestinal microbiota in relation to pathogen challenge in vitro. Denaturing gradient gel electrophoresis analysis demonstrated that GanedenBC(30) supplementation modified the microbial profiles in the fermentation systems compared with controls, with profiles clustering according to treatment. Overall, GanedenBC(30) supplementation did not elicit major changes in bacterial population counts in vitro, although notably higher Bcoa191 counts were seen following probiotic supplementation (compared to the controls). Pathogen challenge did not elicit significant modification of the microbial counts in vitro, although notably higher Clit135 counts were seen in the control system post-Clostridium difficile challenge than in the corresponding GanedenBC(30)-supplemented systems. Sporulation appears to be associated with the anti-microbial activity of GanedenBC(30), suggesting that a bi-modal lifecycle of GanedenBC(30)in vivo may lead to anti-microbial activity in distal regions of the gastrointestinal tract. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Evaluation of surveillance methods for monitoring house fly abundance and activity on large commercial dairy operations.

    PubMed

    Gerry, Alec C; Higginbotham, G E; Periera, L N; Lam, A; Shelton, C R

    2011-06-01

    Relative house fly, Musca domestica L., activity at three large dairies in central California was monitored during the peak fly activity period from June to August 2005 by using spot cards, fly tapes, bait traps, and Alsynite traps. Counts for all monitoring methods were significantly related at two of three dairies; with spot card counts significantly related to fly tape counts recorded the same week, and both spot card counts and fly tape counts significantly related to bait trap counts 1-2 wk later. Mean fly counts differed significantly between dairies, but a significant interaction between dairies sampled and monitoring methods used demonstrates that between-dairy comparisons are unwise. Estimate precision was determined by the coefficient of variability (CV) (or SE/mean). Using a CV = 0.15 as a desired level of estimate precision and assuming an integrate pest management (IPM) action threshold near the peak house fly activity measured by each monitoring method, house fly monitoring at a large dairy would require 12 spot cards placed in midafternoon shaded fly resting sites near cattle or seven bait traps placed in open areas near cattle. Software (FlySpotter; http://ucanr.org/ sites/FlySpotter/download/) using computer vision technology was developed to count fly spots on a scanned image of a spot card to dramatically reduce time invested in monitoring house flies. Counts provided by the FlySpotter software were highly correlated to visual counts. The use of spot cards for monitoring house flies is recommended for dairy IPM programs.

  11. Elevated Steady State WBC and Platelet Counts Are Associated with Frequent Emergency Room Use in Adults with Sickle Cell Anemia

    PubMed Central

    Danda, Neeraja; Etzion, Zipora

    2015-01-01

    Introduction Sickle cell anemia has many sequelae that result in emergency department (ED) use, but a minority of patients with sickle cell disease are frequent utilizers and make up the majority of ED visits. If patients who are likely to be frequent ED can be identified in steady state, they can be treated with disease modifying agents in an attempt to reduce ED use frequency. We sought to identify steady state markers for frequent ED use. Methods We identified all patients with SS/Sβ0 seen at our facilities in 2012. Health care utilization over the entire year was calculated and ED visit numbers categorized as either 0–1, 2–5, or 6 or more visits a year. Steady state and acutely active laboratory parameters were collected and analyzed using analysis of variance models and odds ratios. Results 432 adult sickle cell patients were identified, ages 18–87, 54% female, and 38% had been prescribed hydroxyurea. Of the 432 patients,192 had 0–1 visits in the year, 144 had 2–5 visits in the year, and 96 had >6 visits for a total of 2259 visits. Those who had >6 visits accounted for 1750 (77%) of the total visits for the year. When steady state laboratory markers were examined, each additional 50x109/L platelets was associated with 22% greater risk (p < .001); each 1x109/L of WBC was associated with 11% greater risk (p = .003), and each 1g/dL Hb was associated with 23% lower risk (p = .007) of >6 ED visits/year. We did not observe a relationship between baseline HbF, LDH or reticulocyte count with >6 ED visits. Conclusion Patients with elevated white blood cell counts, elevated platelet counts, and low hemoglobin levels exhibited higher risk for frequent ED utilization and could be candidates for early and aggressive therapy with disease modifying agents. PMID:26248283

  12. Parameter Estimation in Astronomy with Poisson-Distributed Data. 1; The (CHI)2(gamma) Statistic

    NASA Technical Reports Server (NTRS)

    Mighell, Kenneth J.

    1999-01-01

    Applying the standard weighted mean formula, [Sigma (sub i)n(sub i)ssigma(sub i, sup -2)], to determine the weighted mean of data, n(sub i), drawn from a Poisson distribution, will, on average, underestimate the true mean by approx. 1 for all true mean values larger than approx.3 when the common assumption is made that the error of the i th observation is sigma(sub i) = max square root of n(sub i), 1).This small, but statistically significant offset, explains the long-known observation that chi-square minimization techniques which use the modified Neyman'chi(sub 2) statistic, chi(sup 2, sub N) equivalent Sigma(sub i)((n(sub i) - y(sub i)(exp 2)) / max(n(sub i), 1), to compare Poisson - distributed data with model values, y(sub i), will typically predict a total number of counts that underestimates the true total by about 1 count per bin. Based on my finding that weighted mean of data drawn from a Poisson distribution can be determined using the formula [Sigma(sub i)[n(sub i) + min(n(sub i), 1)](n(sub i) + 1)(exp -1)] / [Sigma(sub i)(n(sub i) + 1)(exp -1))], I propose that a new chi(sub 2) statistic, chi(sup 2, sub gamma) equivalent, should always be used to analyze Poisson- distributed data in preference to the modified Neyman's chi(exp 2) statistic. I demonstrated the power and usefulness of,chi(sub gamma, sup 2) minimization by using two statistical fitting techniques and five chi(exp 2) statistics to analyze simulated X-ray power - low 15 - channel spectra with large and small counts per bin. I show that chi(sub gamma, sup 2) minimization with the Levenberg - Marquardt or Powell's method can produce excellent results (mean slope errors approx. less than 3%) with spectra having as few as 25 total counts.

  13. Using Christmas Bird Count data in analysis of population change

    USGS Publications Warehouse

    Sauer, J.R.; Link, W.A.

    2002-01-01

    The scientific credibility of Christmas Bird Count (CBC) results depend on the development and implementation of appropriate methods of statistical analysis. The key to any successful analysis of CBC data is to begin with a careful review of how the limitations of the data are likely to influence the results of the analysis, then to choose methods of analysis that accommodate as much as possible the limitations of the survey. For our analyses of CBC data, we develop a flexible model for effort adjustment and use information from the data to guide the selection of the best model. We include geographic structuring to accommodate the regional variation in number of samples, use a model that allows for overdispersed poisson data appropriate for counts, and employ empirical Bayes procedures to accommodate differences in quality of information in regional summaries. This generalized linear model approach is very flexible, and can be applied to a variety of studies focused on factors influencing wintering bird populations. In particular, the model can be easily modified to contain covariates, allowing for assessment of associations between CBC counts and winter weather, disturbance, and a variety of other environmental factors. These new survey analysis methods have added value in that they provide insights into changes in survey design that can enhance the value of the information. The CBC has been extremely successful as a tool for increasing public interest in birding and bird conservation. Use of the information for bird conservation creates new demands on quality of information, and it is important to maintain a dialogue between users of the information, information needs for the analyses, and survey coordinators and participants. Our work as survey analysts emphasizes the value and limitations of existing data, and provides some indications of what features of the survey could be modified to make the survey a more reliable source of bird population data. Surveys only remain useful if they adapt to current needs, while still maintaining consistency with historical goals.

  14. Changes in antiretroviral therapy guidelines: implications for public health policy and public purses.

    PubMed

    Hamilton, Alex; Garcia-Calleja, Jesus M; Vitoria, Marco; Gilks, Charles; Souteyrand, Yves; De Cock, Kevin; Crowley, Siobhan

    2010-10-01

    The World Health Organization (WHO) published a revision of the antiretroviral therapy (ART) guidelines and now recommends ART for all those with a CD4 cell count ≤350/mm(3), for people with HIV and active tuberculosis (TB) or chronic active hepatitis B irrespective of CD4 cell count and all HIV-positive pregnant women. A study was undertaken to estimate the impact of the new guidelines using four countries as examples. The current WHO/UNAIDS country projections were accessed based on the 2007 estimates for Zambia, Kenya, Cameroon and Vietnam. New projections were created using Spectrum. CD4 progression rates to need for ART were modified and compared with the baseline projections. The pattern of increased need for treatment is similar across the four projections. Initiating treatment at a CD4 count <250/mm(3) will increase the need for treatment by a median of 22% immediately, initiating ART at a CD4 count <350/mm(3) increases the need for treatment by a median of 60%, and the need for treatment doubles if ART is commenced at a CD4 count <500/mm(3). Initiating ART at a CD4 cell count <250/mm(3) would increase the need for treatment by a median of around 15% in 2012; initiating treatment at a CD4 count <350/mm(3) increases the need for treatment by a median of 42% across the same projections and about 84% if CD4 <500/mm(3) was used. The projections indicate that initiating ART earlier in the course of the disease by increasing the threshold for the initiation of ART would increase the numbers of adults in need of treatment immediately and in the future.

  15. The application of generalized, cyclic, and modified numerical integration algorithms to problems of satellite orbit computation

    NASA Technical Reports Server (NTRS)

    Chesler, L.; Pierce, S.

    1971-01-01

    Generalized, cyclic, and modified multistep numerical integration methods are developed and evaluated for application to problems of satellite orbit computation. Generalized methods are compared with the presently utilized Cowell methods; new cyclic methods are developed for special second-order differential equations; and several modified methods are developed and applied to orbit computation problems. Special computer programs were written to generate coefficients for these methods, and subroutines were written which allow use of these methods with NASA's GEOSTAR computer program.

  16. Relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts.

    PubMed

    Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki

    2015-01-01

    Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy.

  17. Relationships among Indoor, Outdoor, and Personal Airborne Japanese Cedar Pollen Counts

    PubMed Central

    Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki

    2015-01-01

    Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy. PMID:26110813

  18. Special Issue on "Instanton Counting: Moduli Spaces, Representation Theory, and Integrable Systems"

    NASA Astrophysics Data System (ADS)

    Bruzzo, Ugo; Sala, Francesco

    2016-11-01

    This special issue of the Journal of Geometry and Physics collects some papers that were presented during the workshop ;Instanton Counting: Moduli Spaces, Representation Theory, and Integrable Systems; that took place at the Lorentz Center in Leiden, The Netherlands, from 16 to 20 June 2014. The workshop was supported by the Lorentz Center, the ;Geometry and Quantum Theory; Cluster, Centre Européen pour les Mathématiques, la Physique et leurs Interactions (Lille, France), Laboratoire Angevin de Recherche en Mathématiques (Angers, France), SISSA (Trieste, Italy), and Foundation Compositio (Amsterdam, the Netherlands). We deeply thank all these institutions for making the workshop possible. We also thank the other organizers of the workshop, Professors Dimitri Markushevich, Vladimir Rubtsov and Sergey Shadrin, for their efforts and great collaboration.

  19. Wavelets, ridgelets, and curvelets for Poisson noise removal.

    PubMed

    Zhang, Bo; Fadili, Jalal M; Starck, Jean-Luc

    2008-07-01

    In order to denoise Poisson count data, we introduce a variance stabilizing transform (VST) applied on a filtered discrete Poisson process, yielding a near Gaussian process with asymptotic constant variance. This new transform, which can be deemed as an extension of the Anscombe transform to filtered data, is simple, fast, and efficient in (very) low-count situations. We combine this VST with the filter banks of wavelets, ridgelets and curvelets, leading to multiscale VSTs (MS-VSTs) and nonlinear decomposition schemes. By doing so, the noise-contaminated coefficients of these MS-VST-modified transforms are asymptotically normally distributed with known variances. A classical hypothesis-testing framework is adopted to detect the significant coefficients, and a sparsity-driven iterative scheme reconstructs properly the final estimate. A range of examples show the power of this MS-VST approach for recovering important structures of various morphologies in (very) low-count images. These results also demonstrate that the MS-VST approach is competitive relative to many existing denoising methods.

  20. Vitamin E modifies the ultrastructure of testis and epididymis in mice exposed to lead intoxication.

    PubMed

    Fahim, Mohamed A; Tariq, Saeed; Adeghate, Ernest

    2013-05-01

    Lead (Pb) is known to cause abnormal function of several systems including the male reproductive system, where it has been shown to reduce sperm count. In order to examine the morphological basis of the reduction in sperm count and a possible effect of vitamin E, lead acetate (1 mg/kg body weight) was given to control and vitamin E-treated mice daily, intraperitoneally for 3 weeks. The testis and body of epididymis of the mice were subjected to electron microscopy study. Pb caused degenerative changes in spermatids inducing vacuolization and a reduction in the number of cytoplasmic organelles in Leydig cells. Pb also destroyed the stereocilia of epididymal epithelium. The addition of vitamin E ameliorated the severity of these morphological changes. In conclusion, Pb-induced reduction in sperm count may be due to changes in the ultrastructure of spermatids, epididymal epithelia and Leydig cells. These changes can be reduced by vitamin E. Copyright © 2012 Elsevier GmbH. All rights reserved.

  1. Point-by-point compositional analysis for atom probe tomography.

    PubMed

    Stephenson, Leigh T; Ceguerra, Anna V; Li, Tong; Rojhirunsakool, Tanaporn; Nag, Soumya; Banerjee, Rajarshi; Cairney, Julie M; Ringer, Simon P

    2014-01-01

    This new alternate approach to data processing for analyses that traditionally employed grid-based counting methods is necessary because it removes a user-imposed coordinate system that not only limits an analysis but also may introduce errors. We have modified the widely used "binomial" analysis for APT data by replacing grid-based counting with coordinate-independent nearest neighbour identification, improving the measurements and the statistics obtained, allowing quantitative analysis of smaller datasets, and datasets from non-dilute solid solutions. It also allows better visualisation of compositional fluctuations in the data. Our modifications include:.•using spherical k-atom blocks identified by each detected atom's first k nearest neighbours.•3D data visualisation of block composition and nearest neighbour anisotropy.•using z-statistics to directly compare experimental and expected composition curves. Similar modifications may be made to other grid-based counting analyses (contingency table, Langer-Bar-on-Miller, sinusoidal model) and could be instrumental in developing novel data visualisation options.

  2. 99Tc atom counting by quadrupole ICP-MS. Optimisation of the instrumental response

    NASA Astrophysics Data System (ADS)

    Más, José L.; Garcia-León, Manuel; Bolívar, Juan P.

    2002-05-01

    In this paper, an extensive work is done on the specific tune of a conventional ICP-MS for 99Tc atom counting. For this, two methods have been used and compared: the partial variable control method and the 5D Simplex method. Instrumental limits of detection of 0.2 and 0.8 ppt, respectively, were obtained. They are noticeably lower than that found with the automatic tune method of the spectrometer, 47 ppt, which shows the need of a specific tune when very low levels of 99Tc have to be determined. A study is presented on the mass interferences for 99Tc. Our experiments show that the formation of polyatomic atoms or refractory oxides as well as 98Mo hydrides seem to be irrelevant for 99Tc atom counting. The opposite occurs with the presence of isobaric interferences, i.e. 99Ru, and the effect of abundance sensitivity, or low-mass resolution, which can modify the response at m/ z=99 to a non-negligible extent.

  3. Rain volume estimation over areas using satellite and radar data

    NASA Technical Reports Server (NTRS)

    Doneaud, A. A.; Vonderhaar, T. H.

    1985-01-01

    An investigation of the feasibility of rain volume estimation using satellite data following a technique recently developed with radar data called the Arera Time Integral was undertaken. Case studies were selected on the basis of existing radar and satellite data sets which match in space and time. Four multicell clusters were analyzed. Routines for navigation remapping amd smoothing of satellite images were performed. Visible counts were normalized for solar zenith angle. A radar sector of interest was defined to delineate specific radar echo clusters for each radar time throughout the radar echo cluster lifetime. A satellite sector of interest was defined by applying small adjustments to the radar sector using a manual processing technique. The radar echo area, the IR maximum counts and the IR counts matching radar echo areas were found to evolve similarly, except for the decaying phase of the cluster where the cirrus debris keeps the IR counts high.

  4. Photon-counting detector arrays based on microchannel array plates. [for image enhancement

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.

    1975-01-01

    The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

  5. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    PubMed

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Risk factors associated with low CD4+ lymphocyte count among HIV-positive pregnant women in Nigeria.

    PubMed

    Abimiku, Alash'le; Villalba-Diebold, Pacha; Dadik, Jelpe; Okolo, Felicia; Mang, Edwina; Charurat, Man

    2009-09-01

    To determine the risk factors for CD4+ lymphocyte counts of 200 cells/mm(3) or lower in HIV-positive pregnant women in Nigeria. A cross-sectional data analysis from a prospective cohort of 515 HIV-positive women attending a prenatal clinic. Risk of a low CD4+ count was estimated using logistic regression analysis. CD4+ lymphocyte counts of 200 cells/mm(3) or lower (280+/-182 cells/mm(3)) were recorded in 187 (36.3%) out of 515 HIV-positive pregnant women included in the study. Low CD4+ count was associated with older age (adjusted odds ratio [aOR] 10.71; 95% confidence interval [CI], 1.20-95.53), lack of condom use (aOR, 5.16; 95% CI, 1.12-23.8), history of genital ulcers (aOR, 1.78; 95% CI, 1.12-2.82), and history of vaginal discharge (aOR; 1.62; 1.06-2.48). Over 35% of the HIV-positive pregnant women had low CD4+ counts, indicating the need for treatment. The findings underscore the need to integrate prevention of mother-to-child transmission with HIV treatment and care, particularly services for sexually transmitted infections.

  7. Measurement of antral follicle count in patients undergoing in vitro fertilization treatment: results of a worldwide web-based survey.

    PubMed

    Christianson, Mindy S; Shoham, Gon; Tobler, Kyle J; Zhao, Yulian; Cordeiro, Christina N; Leong, Milton; Shoham, Zeev

    2015-10-01

    The purpose of the present study was to identify trends in the therapeutic approaches used to measure antral follicle count (AFC) in patients undergoing in vitro fertilization (IVF) treatment worldwide. A retrospective evaluation utilizing the results of a web-based survey, IVF-Worldwide ( www.IVF-Worldwide.com ), was performed. Responses from 796 centers representing 593,200 cycles were evaluated. The majority of respondents (71.2 %) considered antral follicle count as a mandatory part of their practice with most (69.0 %) measuring AFC in the follicular phase. Most respondents (89.7 %) reported that they would modify the IVF stimulation protocol based on the AFC. There was considerable variation regarding a limit for the number of antral follicles required to initiate an IVF cycle with 46.1 % designating three antral follicles as their limit, 39.9 % selecting either four or five follicles as their limit, and 14.0 % reporting a higher cutoff criteria. With respect to antral follicle size, 61.5 % included follicles ranging between 2 and 10 mm in the AFC. When asked to identify the best predictor of ovarian hyper-response during IVF cycles, AFC was selected most frequently (49.4 %), followed by anti-Mullerian hormone level (42.7 %). Age was selected as the best predictor of ongoing pregnancy rate in 81.7 % of respondents. While a large proportion of respondents utilized AFC as part of their daily practice and modified IVF protocol based on the measurement, the majority did not consider AFC as the best predictor of ongoing pregnancy rate.

  8. Interaction of Vitamin D and Smoking on Inflammatory Markers in the Urban Elderly.

    PubMed

    Lee, Hyemi; Kim, Kyoung-Nam; Lim, Youn-Hee; Hong, Yun-Chul

    2015-09-01

    Epidemiological studies have reported that vitamin D deficiency is associated with inflammatory disease. Smoking is a well-known risk factor for inflammation. However, few studies have investigated the interactive effect of vitamin D deficiency and smoking on inflammation. This study aims to investigate the interaction of vitamin D and smoking with inflammatory markers in the urban elderly. We used data from the Korean Elderly Environmental Panel Study, which began in August 2008 and ended in August 2010, and included 560 Koreans ≥60 years old living in Seoul. Data was collected via questionnaires that included items about smoking status at the first visit. Vitamin D levels, high-sensitivity C-reactive protein (hs-CRP), and white blood cell (WBC) counts were repeatedly measured up to three times. The association of vitamin D and hs-CRP was significant after adjusting for known confounders (β=-0.080, p=0.041). After separate analysis by smoking status, the association of vitamin D deficiency and hs-CRP in smokers was stronger than that in nonsmokers (smokers: β=-0.375, p=0.013; non-smokers: β=-0.060, p=0.150). Smoking status was an effect modifier that changed the association between vitamin D deficiency and hs-CRP (interaction estimate: β=-0.254, p=0.032). Vitamin D was not significantly associated with WBC count (β=0.003, p=0.805). Vitamin D deficiency was associated with hs-CRP in the urban elderly. Smoking status was an effect modifier of this association. Vitamin D deficiency was not significantly associated with WBC count.

  9. Integrating Child Health Information Systems

    PubMed Central

    Hinman, Alan R.; Eichwald, John; Linzer, Deborah; Saarlas, Kristin N.

    2005-01-01

    The Health Resources and Services Administration and All Kids Count (a national technical assistance center fostering development of integrated child health information systems) have been working together to foster development of integrated child health information systems. Activities have included: identification of key elements for successful integration of systems; development of principles and core functions for the systems; a survey of state and local integration efforts; and a conference to develop a common vision for child health information systems to meet medical care and public health needs. We provide 1 state (Utah) as an example that is well on the way to development of integrated child health information systems. PMID:16195524

  10. Lifetime Prediction of IGBT in a STATCOM Using Modified-Graphical Rainflow Counting Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gopi Reddy, Lakshmi Reddy; Tolbert, Leon M; Ozpineci, Burak

    Rainflow algorithms are one of the best counting methods used in fatigue and failure analysis [17]. There have been many approaches to the rainflow algorithm, some proposing modifications. Graphical Rainflow Method (GRM) was proposed recently with a claim of faster execution times [10]. However, the steps of the graphical method of rainflow algorithm, when implemented, do not generate the same output as the four-point or ASTM standard algorithm. A modified graphical method is presented and discussed in this paper to overcome the shortcomings of graphical rainflow algorithm. A fast rainflow algorithm based on four-point algorithm but considering point comparison thanmore » range comparison is also presented. A comparison between the performances of the common rainflow algorithms [6-10], including the proposed methods, in terms of execution time, memory used, and efficiency, complexity, and load sequences is presented. Finally, the rainflow algorithm is applied to temperature data of an IGBT in assessing the lifetime of a STATCOM operating for power factor correction of the load. From 5-minute data load profiles available, the lifetime is estimated to be at 3.4 years.« less

  11. Modeling the kinetics of survival of Staphylococcus aureus in regional yogurt from goat's milk.

    PubMed

    Bednarko-Młynarczyk, E; Szteyn, J; Białobrzewski, I; Wiszniewska-Łaszczych, A; Liedtke, K

    2015-01-01

    The aim of this study was to determine the kinetics of the survival of the test strain of Staphylococcus aureus in the product investigated. Yogurt samples were contaminated with S. aure to an initial level of 10(3)-10(4) cfu/g. The samples were then stored at four temperatures: 4, 6, 20, 22°C. During storage, the number of S. aureus forming colonies in a gram of yogurt was determined every two hours. Based on the results of the analysis culture the curves of survival were plotted. Three primary models were selected to describe the kinetics of changes in the count of bacteria: Cole's model, a modified model of Gompertz and the model of Baranyi and Roberts. Analysis of the model fit carried out based on the average values of Pearson's correlation coefficient, between the modeled and measured values, showed that the Cole's model had the worst fit. The modified Gompertz model showed the count of S. aureus as a negative value. These drawbacks were not observed in the model of Baranyi and Roberts. For this reason, this model best reflects the kinetics of changes in the number of staphylococci in yogurt.

  12. Evolving Postmortems as Teams Evolve Through TxP

    DTIC Science & Technology

    2014-12-01

    Instead of waiting for SEI to compile enough data to repeat this kind of analysis for the system integration test domain , a system integration test team...and stand up their Team Test Process (TTP). Some abilities, like planning on how many mistakes will be made by the team in producing a test procedure...can only be performed after the team has determined a) which mistakes count in the domain of system integration testing, b) what units to use to

  13. Testing the Model: A Phase 1/11 Randomized Double Blind Placebo Control Trial of Targeted Therapeutics: Liposomal Glutathione and Curcumin

    DTIC Science & Technology

    2016-10-01

    Can non- specific cellular immunity protect HIV-infected persons with very low CD4 counts? Presented at Conference on Integrating Psychology and...Under Review. 50. Nierenberg B, Cooper S, Feuer SJ, Broderick G. Applying Network Medicine to Chronic Illness: A Model for Integrating Psychology ...function in these subjects as compared to GW era sedentary healthy controls. We applied an integrative systems- based approach rooted in computational

  14. Testing the Model: A Phase 1/11 Randomized Double Blind Placebo Control Trial of Targeted Therapeutics: Liposomal Glutathione and Curcumin

    DTIC Science & Technology

    2017-10-01

    HIV-infected persons with very low CD4 counts? Presented at Conference on Integrating Psychology and Medicine, Waheki Island, Auckland, NZ, 10-12th...SJ, Broderick G. Applying Network Medicine to Chronic Illness: A Model for Integrating Psychology into Routine Care. Amer Psych, 2015. Under review...function in these subjects as compared to GW era sedentary healthy controls. We applied an integrative systems- based approach rooted in

  15. Eight-Channel Continuous Timer

    NASA Technical Reports Server (NTRS)

    Cole, Steven

    2004-01-01

    A custom laboratory electronic timer circuit measures the durations of successive cycles of nominally highly stable input clock signals in as many as eight channels, for the purpose of statistically quantifying the small instabilities of these signals. The measurement data generated by this timer are sent to a personal computer running software that integrates the measurements to form a phase residual for each channel and uses the phase residuals to compute Allan variances for each channel. (The Allan variance is a standard statistical measure of instability of a clock signal.) Like other laboratory clock-cycle-measuring circuits, this timer utilizes an externally generated reference clock signal having a known frequency (100 MHz) much higher than the frequencies of the input clock signals (between 100 and 120 Hz). It counts the number of reference-clock cycles that occur between successive rising edges of each input clock signal of interest, thereby affording a measurement of the input clock-signal period to within the duration (10 ns) of one reference clock cycle. Unlike typical prior laboratory clock-cycle-measuring circuits, this timer does not skip some cycles of the input clock signals. The non-cycle-skipping feature is an important advantage because in applications that involve integration of measurements over long times for characterizing nominally highly stable clock signals, skipping cycles can degrade accuracy. The timer includes a field-programmable gate array that functions as a 20-bit counter running at the reference clock rate of 100 MHz. The timer also includes eight 20-bit latching circuits - one for each channel - at the output terminals of the counter. Each transition of an input signal from low to high causes the corresponding latching circuit to latch the count at that instant. Each such transition also sets a status flip-flop circuit to indicate the presence of the latched count. A microcontroller reads the values of all eight status flipflops and then reads the latched count for each channel for which the flip-flop indicates the presence of a count. Reading the count for each channel automatically causes the flipflop of that channel to be reset. The microcontroller places the counts in time order, identifies the channel number for each count, and transmits these data to the personal computer.

  16. The calibration of photographic and spectroscopic films. The utilization of the digital image processor in the determination of aging of the surf clam (Spisula solidissima)

    NASA Technical Reports Server (NTRS)

    Peters, Kevin A.; Hammond, Ernest C., Jr.

    1987-01-01

    The age of the surf clam (Spisula solidissima) can be determined with the use of the Digital Image Processor. This technique is used in conjunction with a modified method for aging, refined by John Ropes of the Woods Hole Laboratory, Massachusetts. This method utilizes a thinned sectioned chondrophore of the surf clam which contains annual rings. The rings of the chondrophore are then counted to determine age. By digitizing the chondrophore, the Digital Image Processor is clearly able to separate these annual rings more accurately. This technique produces an easier and more efficient way to count annual rings to determine the age of the surf clam.

  17. Alkali halide microstructured optical fiber for X-ray detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeHaven, S. L., E-mail: stanton.l.dehaven@nasa.gov, E-mail: russel.a.wincheski@nasa.gov; Wincheski, R. A., E-mail: stanton.l.dehaven@nasa.gov, E-mail: russel.a.wincheski@nasa.gov; Albin, S., E-mail: salbin@nsu.edu

    Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. Themore » results and associated materials difference are discussed.« less

  18. Instrumentation for laser physics and spectroscopy using 32-bit microcontrollers with an Android tablet interface

    NASA Astrophysics Data System (ADS)

    Eyler, E. E.

    2013-10-01

    Several high-performance lab instruments suitable for manual assembly have been developed using low-pin-count 32-bit microcontrollers that communicate with an Android tablet via a USB interface. A single Android tablet app accommodates multiple interface needs by uploading parameter lists and graphical data from the microcontrollers, which are themselves programmed with easily modified C code. The hardware design of the instruments emphasizes low chip counts and is highly modular, relying on small "daughter boards" for special functions such as USB power management, waveform generation, and phase-sensitive signal detection. In one example, a daughter board provides a complete waveform generator and direct digital synthesizer that fits on a 1.5 in. × 0.8 in. circuit card.

  19. Feedback Integrators

    NASA Astrophysics Data System (ADS)

    Chang, Dong Eui; Jiménez, Fernando; Perlmutter, Matthew

    2016-12-01

    A new method is proposed to numerically integrate a dynamical system on a manifold such that the trajectory stably remains on the manifold and preserves the first integrals of the system. The idea is that given an initial point in the manifold we extend the dynamics from the manifold to its ambient Euclidean space and then modify the dynamics outside the intersection of the manifold and the level sets of the first integrals containing the initial point such that the intersection becomes a unique local attractor of the resultant dynamics. While the modified dynamics theoretically produces the same trajectory as the original dynamics, it yields a numerical trajectory that stably remains on the manifold and preserves the first integrals. The big merit of our method is that the modified dynamics can be integrated with any ordinary numerical integrator such as Euler or Runge-Kutta. We illustrate this method by applying it to three famous problems: the free rigid body, the Kepler problem and a perturbed Kepler problem with rotational symmetry. We also carry out simulation studies to demonstrate the excellence of our method and make comparisons with the standard projection method, a splitting method and Störmer-Verlet schemes.

  20. Comparison of U.S. Geological Survey and Ohio Environmental Protection Agency fish-collection methods using the index of biotic integrity and modified index of well-being, 1996-97

    USGS Publications Warehouse

    Covert, S. Alex

    2001-01-01

    The U.S. Geological Survey (USGS) and Ohio Environmental Protection Agency (OEPA) collected data on fish from 10 stream sites in 1996 and 3 stream sites in 1997 as part of a comparative study of fish community assessment methods. The sites sampled represent a wide range of basin sizes (ranging from 132?6,330 square kilometers) and surrounding land-use types (urban, agricultural, and mixed). Each agency used its own fish-sampling protocol. Using the Index of Biotic Integrity and Modified Index of Well-Being, differences between data sets were tested for significance by means of the Wilcoxon signed-ranks test (a = 0.05). Results showed that the median of Index of Biotic Integrity differences between data sets was not significantly different from zero (p = 0.2521); however, the same statistical test showed the median differences in the Modified Index of Well-Being scores to be significantly different from zero (p = 0.0158). The differences observed in the Index of Biotic Integrity scores are likely due to natural variability, increased variability at sites with degraded water quality, differences in sampling methods, and low-end adjustments in the Index of Biotic Integrity calculation when fewer than 50 fish were collected. The Modified Index of Well-Being scores calculated by OEPA were significantly higher than those calculated by the USGS. This finding was attributed to the comparatively large numbers and biomass of fish collected by the OEPA. By combining the two indices and viewing them in terms of the percentage attainment of Ohio Warmwater Habitat criteria, the two agencies? data seemed comparable, although the Index of Biotic Integrity scores were more similar than the Modified Index of Well-Being scores.

  1. Incorporating availability for detection in estimates of bird abundance

    USGS Publications Warehouse

    Diefenbach, D.R.; Marshall, M.R.; Mattice, J.A.; Brauning, D.W.

    2007-01-01

    Several bird-survey methods have been proposed that provide an estimated detection probability so that bird-count statistics can be used to estimate bird abundance. However, some of these estimators adjust counts of birds observed by the probability that a bird is detected and assume that all birds are available to be detected at the time of the survey. We marked male Henslow's Sparrows (Ammodramus henslowii) and Grasshopper Sparrows (A. savannarum) and monitored their behavior during May-July 2002 and 2003 to estimate the proportion of time they were available for detection. We found that the availability of Henslow's Sparrows declined in late June to <10% for 5- or 10-min point counts when a male had to sing and be visible to the observer; but during 20 May-19 June, males were available for detection 39.1% (SD = 27.3) of the time for 5-min point counts and 43.9% (SD = 28.9) of the time for 10-min point counts (n = 54). We detected no temporal changes in availability for Grasshopper Sparrows, but estimated availability to be much lower for 5-min point counts (10.3%, SD = 12.2) than for 10-min point counts (19.2%, SD = 22.3) when males had to be visible and sing during the sampling period (n = 80). For distance sampling, we estimated the availability of Henslow's Sparrows to be 44.2% (SD = 29.0) and the availability of Grasshopper Sparrows to be 20.6% (SD = 23.5). We show how our estimates of availability can be incorporated in the abundance and variance estimators for distance sampling and modify the abundance and variance estimators for the double-observer method. Methods that directly estimate availability from bird counts but also incorporate detection probabilities need further development and will be important for obtaining unbiased estimates of abundance for these species.

  2. Analytic model for a weakly dissipative shallow-water undular bore.

    PubMed

    El, G A; Grimshaw, R H J; Kamchatnov, A M

    2005-09-01

    We use the integrable Kaup-Boussinesq shallow water system, modified by a small viscous term, to model the formation of an undular bore with a steady profile. The description is made in terms of the corresponding integrable Whitham system, also appropriately modified by viscosity. This is derived in Riemann variables using a modified finite-gap integration technique for the Ablowitz-Kaup-Newell-Segur (AKNS) scheme. The Whitham system is then reduced to a simple first-order differential equation which is integrated numerically to obtain an asymptotic profile of the undular bore, with the local oscillatory structure described by the periodic solution of the unperturbed Kaup-Boussinesq system. This solution of the Whitham equations is shown to be consistent with certain jump conditions following directly from conservation laws for the original system. A comparison is made with the recently studied dissipationless case for the same system, where the undular bore is unsteady.

  3. A counting-weighted calibration method for a field-programmable-gate-array-based time-to-digital converter

    NASA Astrophysics Data System (ADS)

    Chen, Yuan-Ho

    2017-05-01

    In this work, we propose a counting-weighted calibration method for field-programmable-gate-array (FPGA)-based time-to-digital converter (TDC) to provide non-linearity calibration for use in positron emission tomography (PET) scanners. To deal with the non-linearity in FPGA, we developed a counting-weighted delay line (CWD) to count the delay time of the delay cells in the TDC in order to reduce the differential non-linearity (DNL) values based on code density counts. The performance of the proposed CWD-TDC with regard to linearity far exceeds that of TDC with a traditional tapped delay line (TDL) architecture, without the need for nonlinearity calibration. When implemented in a Xilinx Vertix-5 FPGA device, the proposed CWD-TDC achieved time resolution of 60 ps with integral non-linearity (INL) and DNL of [-0.54, 0.24] and [-0.66, 0.65] least-significant-bit (LSB), respectively. This is a clear indication of the suitability of the proposed FPGA-based CWD-TDC for use in PET scanners.

  4. HSCT Propulsion Airframe Integration Studies

    NASA Technical Reports Server (NTRS)

    Chaney, Steve

    1999-01-01

    The Lockheed Martin spillage study was a substantial effort and is worthy of a separate paper. However, since a paper was not submitted a few of the most pertinent results have been pulled out and included in this paper. The reader is urged to obtain a copy of the complete Boeing Configuration Aerodynamics final 1995 contract report for the complete Lockheed documentation of the spillage work. The supersonic cruise studies presented here focus on the bifurcated - axisymmetric inlet drag delta. In the process of analyzing this delta several test/CFD data correlation problems arose that lead to a correction of the measured drag delta from 4.6 counts to 3.1 counts. This study also lead to much better understanding of the OVERFLOW gridding and solution process, and to increased accuracy of the force and moment data. Detailed observations of the CFD results lead to the conclusion that the 3.1 count difference between the two inlet types could be reduced to approximately 2 counts, with an absolute lower bound of 1.2 counts due to friction drag and the bifurcated lip bevel.

  5. Reticulocytes in sports medicine.

    PubMed

    Banfi, Giuseppe

    2008-01-01

    Reticulocytes are the transitional cells from erythroblasts to mature erythrocytes. Reticulocytes are present in blood for a period of 1-4 days and can be recognized by staining with supravital dyes, such as new methylene blue, or fluorescent markers, which couple residual nucleic acid molecules, a hallmark of the immature forms of erythrocytes. Although reticulocytes could be counted through a microscope (there is a standard of International Committee for Standardisation in Haematology for manual counting), this method is reported to be time consuming, inaccurate and imprecise. The integration of the reticulocyte count in automated haematology systems allowed the widespread use of these parameters, although the lack of calibration material and different markers, technologies and software used in automated systems could engender discrepancies among data obtained from different analytical systems.The importance of reticulocytes in sports medicine derives from their sensitivity, the highest among haematology parameters, in identifying the bone marrow stimulation, especially when recombinant human erythropoietin is fraudulently used. Automated systems are also able to supply information on volume, density and the haemoglobin content of reticulocytes. Some of the related parameters are also used in algorithms for identifying abnormal stimulation of bone marrow as reticulocytes haematocrit. The pre-analytical variability of reticulocytes (transportation, storage, biological variability) should be taken into account in sports medicine also. Reticulocytes remain stable for almost 24 hours at 4 degrees C from blood drawing, they are affected by transportation, and biological variability is not high in general. It could be remarked, however, that the intra-individual variability is high when compared with other haematological parameters such as haemoglobin and haematocrit. The intervals of data reported in athletes are very similar to reference intervals characterizing the general population.The reticulocyte count shows some modifications after training and during the competition season. The variability induced by exercise cannot be overlooked since the so-called haematological passport, a personal athlete's document in which haemoglobin and other parameters are registered, may be introduced by sports federations. Exposure to naturally high altitude and 'living high-training low' programmes determined contentious results on reticulocytes. Simulated high altitude induced by intermittent hypobaric hypoxia does not modify reticulocytes, despite an increase in erythropoietin serum concentration. The variability among athletes competing in different sport disciplines is apparently limited. The knowledge of the behaviour of reticulocytes in training and competitions is crucial for defining their role in an antidoping control context. It is important for sport physicians and clinical pathologists to know the reticulocyte variability in the general population and in athletes, the pre-analytical warnings, the different methodologies for counting reticulocytes and the derived parameters automatically available, and, finally, the possible influence of training, competitions, type of sport and altitude.

  6. Spitzer deep and wide legacy mid- and far-infrared number counts and lower limits of cosmic infrared background

    NASA Astrophysics Data System (ADS)

    Béthermin, M.; Dole, H.; Beelen, A.; Aussel, H.

    2010-03-01

    Aims: We aim to place stronger lower limits on the cosmic infrared background (CIB) brightness at 24 μm, 70 μm and 160 μm and measure the extragalactic number counts at these wavelengths in a homogeneous way from various surveys. Methods: Using Spitzer legacy data over 53.6 deg2 of various depths, we build catalogs with the same extraction method at each wavelength. Completeness and photometric accuracy are estimated with Monte-Carlo simulations. Number count uncertainties are estimated with a counts-in-cells moment method to take galaxy clustering into account. Furthermore, we use a stacking analysis to estimate number counts of sources not detected at 70 μm and 160 μm. This method is validated by simulations. The integration of the number counts gives new CIB lower limits. Results: Number counts reach 35 μJy, 3.5 mJy and 40 mJy at 24 μm, 70 μm, and 160 μm, respectively. We reach deeper flux densities of 0.38 mJy at 70, and 3.1 at 160 μm with a stacking analysis. We confirm the number count turnover at 24 μm and 70 μm, and observe it for the first time at 160 μm at about 20 mJy, together with a power-law behavior below 10 mJy. These mid- and far-infrared counts: 1) are homogeneously built by combining fields of different depths and sizes, providing a legacy over about three orders of magnitude in flux density; 2) are the deepest to date at 70 μm and 160 μm; 3) agree with previously published results in the common measured flux density range; 4) globally agree with the Lagache et al. (2004) model, except at 160 μm, where the model slightly overestimates the counts around 20 and 200 mJy. Conclusions: These counts are integrated to estimate new CIB firm lower limits of 2.29-0.09+0.09 nW m-2 sr-1, 5.4-0.4+0.4 nW m-2 sr-1, and 8.9-1.1+1.1 nW m-2 sr-1 at 24 μm, 70 μm, and 160 μm, respectively, and extrapolated to give new estimates of the CIB due to galaxies of 2.86-0.16+0.19 nW m-2 sr-1, 6.6-0.6+0.7 nW m-2 sr-1, and 14.6-2.9+7.1 nW m-2 sr-1, respectively. Products (point spread function, counts, CIB contributions, software) are publicly available for download at http://www.ias.u-psud.fr/irgalaxies/ Counts and CIB contributions are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/512/A78

  7. Water-soluble mercury ion sensing based on the thymine-Hg2+-thymine base pair using retroreflective Janus particle as an optical signaling probe.

    PubMed

    Chun, Hyeong Jin; Kim, Saemi; Han, Yong Duk; Kim, Dong Woo; Kim, Ka Ram; Kim, Hyo-Sop; Kim, Jae-Ho; Yoon, Hyun C

    2018-05-01

    Herein, we report an optical sensing platform for mercury ions (Hg 2+ ) in water based on the integration of Hg 2+ -mediated thymine-thymine (T-T) stabilization, a biotinylated stem-loop DNA probe, and a streptavidin-modified retroreflective Janus particle (SA-RJP). Two oligonucleotide probes, including a stem-loop DNA probe and an assistant DNA probe, were utilized. In the absence of Hg 2+ , the assistant DNA probe does not hybridize with the stem-loop probe due to their T-T mismatch, so the surface-immobilized stem-loop DNA probe remains a closed hairpin structure. In the presence of Hg 2+ , the DNA forms a double-stranded structure with the loop region via Hg 2+ -mediated T-T stabilization. This DNA hybridization induces stretching of the stem-loop DNA probe, exposing biotin. To translate these Hg 2+ -mediated structural changes in DNA probe into measurable signal, SA-RJP, an optical signaling label, is applied to recognize the exposed biotin. The number of biospecifically bound SA-RJPs is proportional to the concentration of Hg 2+ , so that the concentration of Hg 2+ can be quantitatively analyzed by counting the number of RJPs. Using the system, a highly selective and sensitive measurement of Hg 2+ was accomplished with a limit of detection of 0.027nM. Considering the simplified optical instrumentation required for retroreflection-based RJP counting, RJP-assisted Hg 2+ measurement can be accomplished in a much easier and inexpensive manner. Moreover, the detection of Hg 2+ in real drinking water samples including tap and commercial bottled water was successfully carried out. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors

    NASA Astrophysics Data System (ADS)

    Hsieh, Scott S.; Pelc, Norbert J.

    2014-06-01

    Photon counting x-ray detectors (PCXDs) offer several advantages compared to standard energy-integrating x-ray detectors, but also face significant challenges. One key challenge is the high count rates required in CT. At high count rates, PCXDs exhibit count rate loss and show reduced detective quantum efficiency in signal-rich (or high flux) measurements. In order to reduce count rate requirements, a dynamic beam-shaping filter can be used to redistribute flux incident on the patient. We study the piecewise-linear attenuator in conjunction with PCXDs without energy discrimination capabilities. We examined three detector models: the classic nonparalyzable and paralyzable detector models, and a ‘hybrid’ detector model which is a weighted average of the two which approximates an existing, real detector (Taguchi et al 2011 Med. Phys. 38 1089-102 ). We derive analytic expressions for the variance of the CT measurements for these detectors. These expressions are used with raw data estimated from DICOM image files of an abdomen and a thorax to estimate variance in reconstructed images for both the dynamic attenuator and a static beam-shaping (‘bowtie’) filter. By redistributing flux, the dynamic attenuator reduces dose by 40% without increasing peak variance for the ideal detector. For non-ideal PCXDs, the impact of count rate loss is also reduced. The nonparalyzable detector shows little impact from count rate loss, but with the paralyzable model, count rate loss leads to noise streaks that can be controlled with the dynamic attenuator. With the hybrid model, the characteristic count rates required before noise streaks dominate the reconstruction are reduced by a factor of 2 to 3. We conclude that the piecewise-linear attenuator can reduce the count rate requirements of the PCXD in addition to improving dose efficiency. The magnitude of this reduction depends on the detector, with paralyzable detectors showing much greater benefit than nonparalyzable detectors.

  9. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    NASA Astrophysics Data System (ADS)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.

  10. An analysis of dependency of counting efficiency on worker anatomy for in vivo measurements: whole-body counting

    NASA Astrophysics Data System (ADS)

    Zhang, Binquan; Mille, Matthew; Xu, X. George

    2008-07-01

    In vivo radiobioassay is integral to many health physics and radiological protection programs dealing with internal exposures. The Bottle Manikin Absorber (BOMAB) physical phantom has been widely used for whole-body counting calibrations. However, the shape of BOMAB phantoms—a collection of plastic, cylindrical shells which contain no bones or internal organs—does not represent realistic human anatomy. Furthermore, workers who come in contact with radioactive materials have rather different body shape and size. To date, there is a lack of understanding about how the counting efficiency would change when the calibrated counter is applied to a worker with complicated internal organs or tissues. This paper presents a study on various in vivo counting efficiencies obtained from Monte Carlo simulations of two BOMAB phantoms and three tomographic image-based models (VIP-Man, NORMAN and CNMAN) for a scenario involving homogeneous whole-body radioactivity contamination. The results reveal that a phantom's counting efficiency is strongly dependent on the shape and size of a phantom. Contrary to what was expected, it was found that only small differences in efficiency were observed when the density and material composition of all internal organs and tissues of the tomographic phantoms were changed to water. The results of this study indicate that BOMAB phantoms with appropriately adjusted size and shape can be sufficient for whole-body counting calibrations when the internal contamination is homogeneous.

  11. Neutron counting with cameras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Esch, Patrick; Crisanti, Marta; Mutti, Paolo

    2015-07-01

    A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involvedmore » are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)« less

  12. Local box-counting dimensions of discrete quantum eigenvalue spectra: Analytical connection to quantum spectral statistics

    NASA Astrophysics Data System (ADS)

    Sakhr, Jamal; Nieminen, John M.

    2018-03-01

    Two decades ago, Wang and Ong, [Phys. Rev. A 55, 1522 (1997)], 10.1103/PhysRevA.55.1522 hypothesized that the local box-counting dimension of a discrete quantum spectrum should depend exclusively on the nearest-neighbor spacing distribution (NNSD) of the spectrum. In this Rapid Communication, we validate their hypothesis by deriving an explicit formula for the local box-counting dimension of a countably-infinite discrete quantum spectrum. This formula expresses the local box-counting dimension of a spectrum in terms of single and double integrals of the NNSD of the spectrum. As applications, we derive an analytical formula for Poisson spectra and closed-form approximations to the local box-counting dimension for spectra having Gaussian orthogonal ensemble (GOE), Gaussian unitary ensemble (GUE), and Gaussian symplectic ensemble (GSE) spacing statistics. In the Poisson and GOE cases, we compare our theoretical formulas with the published numerical data of Wang and Ong and observe excellent agreement between their data and our theory. We also study numerically the local box-counting dimensions of the Riemann zeta function zeros and the alternate levels of GOE spectra, which are often used as numerical models of spectra possessing GUE and GSE spacing statistics, respectively. In each case, the corresponding theoretical formula is found to accurately describe the numerically computed local box-counting dimension.

  13. Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need†‡

    PubMed Central

    Jokerst, Jesse V.; Floriano, Pierre N.; Christodoulides, Nicolaos; Simmons, Glennon W.; McDevitt, John T.

    2010-01-01

    Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the treatment of the more than 33 million HIV afflicted people living in resource-scarce settings. Here, the enumeration of CD4+ T lymphocytes is required to establish the level at which the immune system has been compromised. The gold standard method used in developed countries, based on flow cytometry, though widely accepted and accurate, is precluded from widespread use in resource-scarce settings due to its high expense, high technical requirements, difficulty in operation-maintenance and the lack of portability for these sophisticated laboratory-confined systems. As part of continuing efforts to develop practical diagnostic instrumentation, the integration of semiconductor nanocrystals (quantum dots, QDs) into a portable microfluidic-based lymphocyte capture and detection device is completed. This integrated system is capable of isolating and counting selected lymphocyte sub-populations (CD3+CD4+) from whole blood samples. By combining the unique optical properties of the QDs with the sample handling capabilities and cost effectiveness of novel microfluidic systems, a practical, portable lymphocyte measurement modality that correlates nicely with flow cytometry (R2 = 0.97) has been developed. This QD-based system reduces the optical requirements significantly relative to molecular fluorophores and the mini-CD4 counting device is projected to be suitable for use in both point-of-need and resource-scarce settings. PMID:19023471

  14. Liquid nitrogen vapor is comparable to liquid nitrogen for storage of cryopreserved human sperm: evidence from the characteristics of post-thaw human sperm.

    PubMed

    Hu, Jingmei; Zhao, Shidou; Xu, Chengyan; Zhang, Lin; Lu, Shaoming; Cui, Linlin; Ma, Jinlong; Chen, Zi-Jiang

    2015-11-01

    To compare the differences in the characteristics of post-thaw human sperm after storage in either liquid nitrogen (LN2; -196 °C) or LN2 vapor (-167 °C). Experimental study. University hospital. Thirty healthy volunteers who agreed to donate their normal semen samples for infertility or research were included in the study. Semen samples (n = 30) were divided into eight aliquots and frozen. Four aliquots of each human semen sample were stored in LN2 (-196 °C), and the other four aliquots were stored in LN2 vapor (-167 °C). After 1, 3, 6, or 12 months, samples were thawed and analyzed. The motility was evaluated by the manual counting method. The viability was estimated by eosin staining. The morphology was analyzed by Diff-Quik staining. The sperm DNA integrity was determined with acridine orange fluorescent staining, and acrosin activity was assayed by the modified Kennedy method. The characteristics of post-thaw human sperm, including motility, viability, morphology, DNA integrity, and acrosin activity, showed no significant difference between LN2 and LN2 vapor storage for the different time periods. LN2 vapor was comparable to LN2 in post-thaw sperm characteristics, suggesting that LN2 vapor may be substituted for LN2 for the long-term storage of human sperm. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Genetically Modified Food in Perspective: An Inquiry-Based Curriculum to Help Middle School Students Make Sense of Tradeoffs. Research Report

    ERIC Educational Resources Information Center

    Seethaler, Sherry; Linn, Marcia

    2004-01-01

    To understand how students learn about science controversy, this study examines students' reasoning about tradeoffs in the context of a technology-enhanced curriculum about genetically modified food. The curriculum was designed and refined based on the Scaffolded Knowledge Integration Framework to help students sort and integrate their initial…

  16. Effects of Various Types of Situps on Integrated MAP's of the Abdominal Musculature.

    ERIC Educational Resources Information Center

    Noble, Larry

    The electrical activity of the abdominal muscles was tested during situps to determine the effect upon integrated muscle action potential (MAP). The following types of situps were used in testing 18 college males: (1) trunk curls; (2) AAHPER situp; (3) YMCA situp; (4) modified AAHPER situp; and (5) modified YMCA situp. All situps were performed…

  17. Spectrophotometer-Integrating-Sphere System for Computing Solar Absorptance

    NASA Technical Reports Server (NTRS)

    Witte, William G., Jr.; Slemp, Wayne S.; Perry, John E., Jr.

    1991-01-01

    A commercially available ultraviolet, visible, near-infrared spectrophotometer was modified to utilize an 8-inch-diameter modified Edwards-type integrated sphere. Software was written so that the reflectance spectra could be used to obtain solar absorptance values of 1-inch-diameter specimens. A descriptions of the system, spectral reflectance, and software for calculation of solar absorptance from reflectance data are presented.

  18. Exploring the Thermal Limits of IR-Based Automatic Whale Detection (ETAW)

    DTIC Science & Technology

    2013-09-30

    the northward humpback whale migration, which occurs annually rather close to shore near North Stradbroke Island, Queensland, Australia. Based on the...successive northward humpback whale migrations and collecting concurrent independent (double blind) visual observations (modified cue counting), a... Whale Detection (ETAW) Olaf Boebel P.O. Box 120161 27515 Bremerhaven Germany phone: +49 (471) 4831-1879 fax: +49 (471) 4831-1797 email

  19. Appraisal of the sensitising potential of orally and dermally administered mercaptobenzothiazole by a biphasic protocol of the local lymph node assay.

    PubMed

    Ahuja, Varun; Wanner, Reinhard; Platzek, Thomas; Stahlmann, Ralf

    2009-10-01

    Mercaptobenzothiazole (MBT) is used while manufacturing natural rubber products. Our study deals with assessing its allergenic potential following dermal and oral routes of exposure, using a biphasic local lymph node assay (LLNA). Female Balb/c mice were treated with MBT (dermally 3, 10, 30% concentrations in DMSO; orally 1, 10, 100 mg/kg doses in corn oil) on the back (dermal study) or through oral administration (oral study) on days 1-3 followed by auricular application of 3, 10 and 30% concentrations, respectively, on days 15-17. End points determined on day 19 included ear thickness, ear punch weight, lymph node weight, lymph node cell count, and lymphocyte subpopulations (CD4+, CD8+, CD45+). After dermal application of 3% or 10% solution, a significant increase in cell count and lymph node weight along with significant decrease in CD8+ cells was observed. After initial oral administration of 1 mg/kg, we noticed a significant amplification in cell count. Following oral administration of 10 mg/kg, we observed a similar increase in cell count and lymph node weight. The results of our study show that the modified biphasic LLNA protocol can be used to study the sensitising potential of a compound also following the oral route of exposure.

  20. Evaluation of standard and modified M-FC, MacConkey, and Teepol media for membrane filtration counting of fecal coliforms in water.

    PubMed

    Grabow, W O; Hilner, C A; Coubrough, P

    1981-08-01

    MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.

  1. Effectiveness of two synthetic fiber filters for removing white cells from AS-1 red cells.

    PubMed

    Pikul, F J; Farrar, R P; Boris, M B; Estok, L; Marlo, D; Wildgen, M; Chaplin, H

    1989-09-01

    Two commercially available synthetic fiber filters were studied for their effectiveness at removing white cells (WBCs) from AS-1-preserved red cells (RBCs) stored less than or equal to 14 days. In all, 65 filtrations were performed. An automated microprocessor-controlled hydraulic system designed for use with cellulose acetate fiber filters was employed to prepare filtered RBCs before release for transfusion. Studies were also carried out on polyester fiber filters, which are designed to be used in-line during transfusion. Residual WBCs were below the accurate counting range of Coulter counters and of conventional manual chamber counts. An isosmotic ammonium chloride RBC lysis method, plus a modified chamber counting technique, permitted a 270-fold increase over the number of WBCs counted by the conventional manual method. For the polyester fiber-filtered products, residual WBCs per unit were not affected by speed of filtration, prior length of storage, or mechanical tapping during filtration. The effectiveness of WBC removal (mean 99.7%), total residual WBCs (means, 4.8 and 5.5 x 10(6], and RBC recovery (mean, 93%) was the same for both filters. The majority of residual WBCs were lymphocytes. WBC removal and RBC recovery were strikingly superior to results reported with nonfiltration methods.

  2. Ocular Biocompatibility of Nitinol Intraocular Clips

    PubMed Central

    Velez-Montoya, Raul; Erlanger, Michael

    2012-01-01

    Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995

  3. A real-time phoneme counting algorithm and application for speech rate monitoring.

    PubMed

    Aharonson, Vered; Aharonson, Eran; Raichlin-Levi, Katia; Sotzianu, Aviv; Amir, Ofer; Ovadia-Blechman, Zehava

    2017-03-01

    Adults who stutter can learn to control and improve their speech fluency by modifying their speaking rate. Existing speech therapy technologies can assist this practice by monitoring speaking rate and providing feedback to the patient, but cannot provide an accurate, quantitative measurement of speaking rate. Moreover, most technologies are too complex and costly to be used for home practice. We developed an algorithm and a smartphone application that monitor a patient's speaking rate in real time and provide user-friendly feedback to both patient and therapist. Our speaking rate computation is performed by a phoneme counting algorithm which implements spectral transition measure extraction to estimate phoneme boundaries. The algorithm is implemented in real time in a mobile application that presents its results in a user-friendly interface. The application incorporates two modes: one provides the patient with visual feedback of his/her speech rate for self-practice and another provides the speech therapist with recordings, speech rate analysis and tools to manage the patient's practice. The algorithm's phoneme counting accuracy was validated on ten healthy subjects who read a paragraph at slow, normal and fast paces, and was compared to manual counting of speech experts. Test-retest and intra-counter reliability were assessed. Preliminary results indicate differences of -4% to 11% between automatic and human phoneme counting. Differences were largest for slow speech. The application can thus provide reliable, user-friendly, real-time feedback for speaking rate control practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A modified integrated NDVI for improving estimates of terrestrial net primary production

    NASA Technical Reports Server (NTRS)

    Running, Steven W.

    1990-01-01

    Logic is presented for a time-integrated NDVI that is modified by an AVHRR derived surface evaporation resistance factor sigma, and truncated by temperatures that cause plant dormancy, to improve environmental sensitivity. With this approach, NDVI observed during subfreezing temperatures is not integrated. Water stress-related impairment in plant activity is incorporated by reducing the effective NDVI at each integration with sigma, which is derived from the slope of the surface temperature to NDVI ratio for climatically similar zones of the scene. A comparison of surface resistance before and after an extended drought period for a 1200 sq km region of coniferous forest in Montana is presented.

  5. Comprehensive System-Based Architecture for an Integrated High Energy Laser Test Bed

    DTIC Science & Technology

    2015-03-01

    76 4. Comparison of Sensors ................................................................76 B. TRANSMISSION...81 b. Photometers .......................................................................84 4. Comparison of Sensors ...88 a. Flat Plate Target Boards, Ablatives, and Acrylite ...........88 b. Photon-Counting Sensors

  6. Theory of intrinsic linewidth based on fluctuation-dissipation balance for thermal photons in THz quantum-cascade lasers.

    PubMed

    Yamanishi, Masamichi

    2012-12-17

    Intrinsic linewidth formula modified by taking account of fluctuation-dissipation balance for thermal photons in a THz quantum-cascade laser (QCL) is exhibited. The linewidth formula based on the model that counts explicitly the influence of noisy stimulated emissions due to thermal photons existing inside the laser cavity interprets experimental results on intrinsic linewidth, ~91.1 Hz reported recently with a 2.5 THz bound-to-continuum QCL. The line-broadening induced by thermal photons is estimated to be ~22.4 Hz, i.e., 34% broadening. The modified linewidth formula is utilized as a bench mark in engineering of THz thermal photons inside laser cavities.

  7. The association between modifiable well-being risks and productivity: a longitudinal study in pooled employer sample.

    PubMed

    Shi, Yuyan; Sears, Lindsay E; Coberley, Carter R; Pope, James E

    2013-04-01

    To examine the longitudinal relationship between modifiable well-being risks and productivity. A total of 19,121 employees from five employers participated in baseline and follow-up well-being assessment surveys. Multivariate regressions assessed whether changes in absenteeism, presenteeism, and job performance were associated with changes in 19 modifiable well-being risks. Over time, a 5% reduction in total count of well-being risks was significantly associated with 0.74% decrease in absenteeism, 2.38% decrease in presenteeism, and 0.24% increase in performance. High blood pressure, recurring pain, unhealthy diet, inadequate exercise, poor emotional health, poor supervisor relationship, not utilizing strengths doing job, and organization unsupportive of well-being had greater independent contributions in explaining productivity impairment. The often-ignored well-being risks such as work-related and financial health risks provided incremental explanation of longitudinal productivity variations beyond traditional measures of health-related risks.

  8. Effect of storage temperature on the microbial composition of ready-to-use vegetables.

    PubMed

    Caldera, L; Franzetti, L

    2014-02-01

    Four different salad preparations were investigated from microbiological point of view: two were packaged in air and two under Modified Atmosphere. The samples were stored at 4 and 10 °C, and analysed at established times. Total bacterial count (TBC) was taken as the most relevant index to define their hygiene and quality at both temperatures. Lactic acid bacteria, yeasts and moulds were found only occasionally. In general, the most important factor was the packaging technique: TBC was lower when the product is packed under modified conditions. The packaging technique also influences the microbial population: Gram-negative aerobic rods are dominant in air-packaged products, whilst the presence of Enterobacteriaceae becomes important in salads packaged under Modified Atmosphere. Pseudomonas fluorescens, with all its biovars, was the most frequently found species amongst the aerobic isolates, whilst for the Enterobacteriaceae strains, there was no dominant species.

  9. Fractal Analysis of Rock Joint Profiles

    NASA Astrophysics Data System (ADS)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    Surface reliefs of rock joints are analyzed in geotechnics when shear strength of rocky slopes is estimated. The rock joint profiles actually are self-affine fractal curves and computations of their fractal dimensions require special methods. Many papers devoted to the fractal properties of these profiles were published in the past but only a few of those papers employed a convenient computational method that would have guaranteed a sound value of that dimension. As a consequence, anomalously low dimensions were presented. This contribution deals with two computational modifications that lead to sound fractal dimensions of the self-affine rock joint profiles. These are the modified box-counting method and the modified yard-stick method sometimes called the compass method. Both these methods are frequently applied to self-similar fractal curves but the self-affine profile curves due to their self-affine nature require modified computational procedures implemented in computer programs.

  10. PREDICT: Pattern Representation and Evaluation of Data through Integration, Correlation, and Transformation

    DTIC Science & Technology

    2015-02-01

    than 36ºC; 2) heart rate > 90 beats/min; 3) respiratory rate > 20 breaths/min; and 4) white blood cell count > 12,000/mm3 or < 4,000/mm3 which more than...4) white blood cell count 5) heart rate variability 6) blood pressure The challenge is that once these criteria are met, it is often the case that...Figure 7) was not actually meant to be read (no individual variables or numbers). We believed that showing an increasing size (and color and

  11. Microradiography with Semiconductor Pixel Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jakubek, Jan; Cejnarova, Andrea; Dammer, Jiri

    High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.

  12. Measuring the lensing potential with tomographic galaxy number counts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montanari, Francesco; Durrer, Ruth, E-mail: francesco.montanari@unige.ch, E-mail: ruth.durrer@unige.ch

    2015-10-01

    We investigate how the lensing potential can be measured tomographically with future galaxy surveys using their number counts. Such a measurement is an independent test of the standard ΛCDM framework and can be used to discern modified theories of gravity. We perform a Fisher matrix forecast based on galaxy angular-redshift power spectra, assuming specifications consistent with future photometric Euclid-like surveys and spectroscopic SKA-like surveys. For the Euclid-like survey we derive a fitting formula for the magnification bias. Our analysis suggests that the cross correlation between different redshift bins is very sensitive to the lensing potential such that the survey canmore » measure the amplitude of the lensing potential at the same level of precision as other standard ΛCDM cosmological parameters.« less

  13. The development of strategy use in elementary school children: working memory and individual differences.

    PubMed

    Imbo, Ineke; Vandierendonck, André

    2007-04-01

    The current study tested the development of working memory involvement in children's arithmetic strategy selection and strategy efficiency. To this end, an experiment in which the dual-task method and the choice/no-choice method were combined was administered to 10- to 12-year-olds. Working memory was needed in retrieval, transformation, and counting strategies, but the ratio between available working memory resources and arithmetic task demands changed across development. More frequent retrieval use, more efficient memory retrieval, and more efficient counting processes reduced the working memory requirements. Strategy efficiency and strategy selection were also modified by individual differences such as processing speed, arithmetic skill, gender, and math anxiety. Short-term memory capacity, in contrast, was not related to children's strategy selection or strategy efficiency.

  14. Development of an S-band cavity Beam Position Monitor for ATF2

    NASA Astrophysics Data System (ADS)

    Heo, A.; Kim, E.-S.; Kim, H.; Son, D.; Honda, Y.; Tauchi, T.

    2013-04-01

    We have developed an S-band cavity Beam Position Monitor (BPM) in order to measure the position of an electron beam in the final focus area at ATF2, which is the test facility for the final focus design for the International Linear Collider (ILC). The lattice of the ILC Beam Delivery System (BDS) has been modified, requiring a larger physical aperture of 40 mm in the final focus area. The beam orbit measurement in this area is now covered with high resolution S-Band cavity BPMs. In this paper we summarize the design of the cavity BPM and the first experimental results. The calibration slopes were measured as 0.87 counts/μm in the x-coordinate direction and 1.16 counts/μm in the y-coordinate direction.

  15. Photocounting distributions for exponentially decaying sources.

    PubMed

    Teich, M C; Card, H C

    1979-05-01

    Exact photocounting distributions are obtained for a pulse of light whose intensity is exponentially decaying in time, when the underlying photon statistics are Poisson. It is assumed that the starting time for the sampling interval (which is of arbitrary duration) is uniformly distributed. The probability of registering n counts in the fixed time T is given in terms of the incomplete gamma function for n >/= 1 and in terms of the exponential integral for n = 0. Simple closed-form expressions are obtained for the count mean and variance. The results are expected to be of interest in certain studies involving spontaneous emission, radiation damage in solids, and nuclear counting. They will also be useful in neurobiology and psychophysics, since habituation and sensitization processes may sometimes be characterized by the same stochastic model.

  16. A Modified Compound From Paeoniflorin, CP-25, Suppressed Immune Responses and Synovium Inflammation in Collagen-Induced Arthritis Mice.

    PubMed

    Chen, Jingyu; Wang, Ying; Wu, Huaxun; Yan, Shangxue; Chang, Yan; Wei, Wei

    2018-01-01

    Paeoniflorin-6'- O -benzene sulfonate (CP-25) is a modified paeoniflorin, which is the main bioactive component of total glucosides of peony. This study evaluated the anti-inflammatory and immunoregulatory effects of CP-25 in mice with collagen-induced arthritis (CIA) and the potential mechanisms underlying these effects. After the onset of CIA, mice were given CP-25 (17.5, 35, or 70 mg/kg) or methotrexate (MTX, 2.0 mg/kg). The arthritis index, swollen joint count, and joint and spleen histopathology were evaluated. T and B cell subsets were assayed using flow cytometry, while the proliferation of these cells and fibroblast-like synoviocytes (FLSs) were evaluated using the Cell Counting Kit-8. β2-adrenoceptor (β2-AR) expression was assayed using flow cytometry, immunohistochemistry, and western blotting. FLS migration and invasion were assayed using Transwells. CP-25 (35 or 70 mg/kg) attenuated the arthritis index and swollen joint count, alleviated joint and spleen histopathology, suppressed excessive T cell activation, and attenuated humoral immunity in CIA mice. CP-25 increased β2-AR expression on T cells, B cells, dendritic cells, and the synovium in CIA mice. CP-25 up-regulated the β2-AR agonist response and attenuated FLS activation; these effects may reflect CP-25-mediated reduction of β2-AR desensitization due to down-regulation of membrane G protein-coupled receptor kinase 2 expression. These results suggest that CP-25 suppressed immune responses and synovium inflammation in mice with CIA, effects that were associated with reduced β2-AR desensitization and the promotion of β2-AR signaling.

  17. Lyapunov Orbits in the Jupiter System Using Electrodynamic Tethers

    NASA Technical Reports Server (NTRS)

    Bokelmann, Kevin; Russell, Ryan P.; Lantoine, Gregory

    2013-01-01

    Various researchers have proposed the use of electrodynamic tethers for power generation and capture from interplanetary transfers. The effect of tether forces on periodic orbits in Jupiter-satellite systems are investigated. A perturbation force is added to the restricted three-body problem model and a series of simplifications allows development of a conservative system that retains the Jacobi integral. Expressions are developed to find modified locations of equilibrium positions. Modified families of Lyapunov orbits are generated as functions of tether size and Jacobi integral. Zero velocity curves and stability analyses are used to evaluate the dynamical properties of tether-modified orbits.

  18. Adaptive integral backstepping sliding mode control for opto-electronic tracking system based on modified LuGre friction model

    NASA Astrophysics Data System (ADS)

    Yue, Fengfa; Li, Xingfei; Chen, Cheng; Tan, Wenbin

    2017-12-01

    In order to improve the control accuracy and stability of opto-electronic tracking system fixed on reef or airport under friction and external disturbance conditions, adaptive integral backstepping sliding mode control approach with friction compensation is developed to achieve accurate and stable tracking for fast moving target. The nonlinear observer and slide mode controller based on modified LuGre model with friction compensation can effectively reduce the influence of nonlinear friction and disturbance of this servo system. The stability of the closed-loop system is guaranteed by Lyapunov theory. The steady-state error of the system is eliminated by integral action. The adaptive integral backstepping sliding mode controller and its performance are validated by a nonlinear modified LuGre dynamic model of the opto-electronic tracking system in simulation and practical experiments. The experiment results demonstrate that the proposed controller can effectively realise the accuracy and stability control of opto-electronic tracking system.

  19. OBIST methodology incorporating modified sensitivity of pulses for active analogue filter components

    NASA Astrophysics Data System (ADS)

    Khade, R. H.; Chaudhari, D. S.

    2018-03-01

    In this paper, oscillation-based built-in self-test method is used to diagnose catastrophic and parametric faults in integrated circuits. Sallen-Key low pass filter and high pass filter circuits with different gains are used to investigate defects. Variation in seven parameters of operational amplifier (OP-AMP) like gain, input impedance, output impedance, slew rate, input bias current, input offset current, input offset voltage and catastrophic as well as parametric defects in components outside OP-AMP are introduced in the circuit and simulation results are analysed. Oscillator output signal is converted to pulses which are used to generate a signature of the circuit. The signature and pulse count changes with the type of fault present in the circuit under test (CUT). The change in oscillation frequency is observed for fault detection. Designer has flexibility to predefine tolerance band of cut-off frequency and range of pulses for which circuit should be accepted. The fault coverage depends upon the required tolerance band of the CUT. We propose a modification of sensitivity of parameter (pulses) to avoid test escape and enhance yield. Result shows that the method provides 100% fault coverage for catastrophic faults.

  20. Cosmological measurements with general relativistic galaxy correlations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raccanelli, Alvise; Montanari, Francesco; Durrer, Ruth

    We investigate the cosmological dependence and the constraining power of large-scale galaxy correlations, including all redshift-distortions, wide-angle, lensing and gravitational potential effects on linear scales. We analyze the cosmological information present in the lensing convergence and in the gravitational potential terms describing the so-called ''relativistic effects'', and we find that, while smaller than the information contained in intrinsic galaxy clustering, it is not negligible. We investigate how neglecting them does bias cosmological measurements performed by future spectroscopic and photometric large-scale surveys such as SKA and Euclid. We perform a Fisher analysis using the CLASS code, modified to include scale-dependent galaxymore » bias and redshift-dependent magnification and evolution bias. Our results show that neglecting relativistic terms, especially lensing convergence, introduces an error in the forecasted precision in measuring cosmological parameters of the order of a few tens of percent, in particular when measuring the matter content of the Universe and primordial non-Gaussianity parameters. The analysis suggests a possible substantial systematic error in cosmological parameter constraints. Therefore, we argue that radial correlations and integrated relativistic terms need to be taken into account when forecasting the constraining power of future large-scale number counts of galaxy surveys.« less

  1. Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

    PubMed Central

    Cho, Hyo-Min; Barber, William C.; Ding, Huanjun; Iwanczyk, Jan S.; Molloi, Sabee

    2014-01-01

    Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A109Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm2) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a 109Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm−1. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging. PMID:25186390

  2. Mu-Spec - A High Performance Ultra-Compact Photon Counting spectrometer for Space Submillimeter Astronomy

    NASA Technical Reports Server (NTRS)

    Moseley, H.; Hsieh, W.-T.; Stevenson, T.; Wollack, E.; Brown, A.; Benford, D.; Sadleir; U-Yen, I.; Ehsan, N.; Zmuidzinas, J.; hide

    2011-01-01

    We have designed and are testing elements of a fully integrated submillimeter spectrometer based on superconducting microstrip technology. The instrument can offer resolving power R approximately 1500, and its high frequency cutoff is set by the gap of available high performance superconductors. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using planar filter, and detected using photon counting MKID detector. This spectrometer promises to revolutionize submillimeter spectroscopy from space. It replaces instruments with the scale of 1m with a spectrometer on a 10 cm Si wafer. The reduction in mass and volume promises a much higher performance system within available resource in a space mission. We will describe the system and the performance of the components that have been fabricated and tested.

  3. Integrating molecular diagnostic and flow cytometric reporting for improved longitudinal monitoring of HIV patients.

    PubMed Central

    Asare, A. L.; Huda, H.; Klimczak, J. C.; Caldwell, C. W.

    1998-01-01

    Studies have shown that monitoring HIV-infected patients undergoing antiretroviral therapy is best represented by combined measurement of plasma HIV-1 RNA and CD4+ T-lymphocytes [1]. This pilot study at the University of Missouri-Columbia integrates molecular diagnostic and flow cytometric data reporting to provide current and historical HIV-1 RNA levels and CD4+ T-cell counts. The development of a single database for storage and retrieval of these values facilitates composite report generation that includes longitudinal HIV-1 RNA levels and CD4+ T-cell counts for all patients. Results are displayed in tables and plotted graphically within a web browser. This method of data presentation converts individual data points to more useful medical information and could provide clinicians with decision support for improved monitoring of HIV patients undergoing antiretroviral therapy. Images Figure 2 Figure 3 Figure 4 PMID:9929359

  4. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Surface Micromachined Adjustable Micro-Concave Mirror for Bio-Detection Applications

    NASA Astrophysics Data System (ADS)

    Kuo, Ju-Nan; Chen, Wei-Lun; Jywe, Wen-Yuh

    2009-08-01

    We present a bio-detection system integrated with an adjustable micro-concave mirror. The bio-detection system consists of an adjustable micro-concave mirror, micro flow cytometer chip and optical detection module. The adjustable micro-concave mirror can be fabricated with ease using commercially available MEMS foundry services (such as multiuser MEMS processes, MUMPs) and its curvature can be controlled utilizing thermal or electrical effects. Experimental results show that focal lengths of the micro-concave mirror ranging from 313.5 to 2275.0 μm are achieved. The adjustable micro-concave mirror can be used to increase the efficiency of optical detection and provide a high signal-to-noise ratio. The developed micro-concave mirror is integrated with a micro flow cytometer for cell counting applications. Successful counting of fluorescent-labeled beads is demonstrated using the developed method.

  5. [Interconnection of stress and physical development processes in young persons].

    PubMed

    Barbarash, N A; Kuvshinkov, D Iu; Tul'chinskiĭ, M Ia

    2003-01-01

    The physical development (PD) rates, constitutional peculiarities and an integral level of different manifestations of stress-reactivity (SR) were evaluated in 201 students of Medical Academy (73 males and 138 females), aged 17-21; the above parameters were tested by the color method of Luscher, by Teylor's anxiety assessment, by "Individual Minute" measurements, by the iridoscopic count of iris nervous rings, by the "Mathematical Count" technique and by calculating the index of regulatory systems' tension according to the heart rate variability. The highest total SR index, including the SR cardiac manifestations was found in youth to correlate with the lowest PD index. The integral SR level correlated, in youth, inversely with the PD parameters. Such relations are more pronounced in individuals of the abdominal somatic type. The mechanisms and biological significance of SR correlations with the processes of growth and development are under discussion.

  6. Neutronic analysis of the 1D and 1E banks reflux detection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blanchard, A.

    1999-12-21

    Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely,more » the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal {sup 235}U concentration levels to reflux levels remain satisfactory detectable.« less

  7. The utility of point count surveys to predict wildlife interactions with wind energy facilities: An example focused on golden eagles

    USGS Publications Warehouse

    Sur, Maitreyi; Belthoff, James R.; Bjerre, Emily R.; Millsap, Brian A.; Katzner, Todd

    2018-01-01

    Wind energy development is rapidly expanding in North America, often accompanied by requirements to survey potential facility locations for existing wildlife. Within the USA, golden eagles (Aquila chrysaetos) are among the most high-profile species of birds that are at risk from wind turbines. To minimize golden eagle fatalities in areas proposed for wind development, modified point count surveys are usually conducted to estimate use by these birds. However, it is not always clear what drives variation in the relationship between on-site point count data and actual use by eagles of a wind energy project footprint. We used existing GPS-GSM telemetry data, collected at 15 min intervals from 13 golden eagles in 2012 and 2013, to explore the relationship between point count data and eagle use of an entire project footprint. To do this, we overlaid the telemetry data on hypothetical project footprints and simulated a variety of point count sampling strategies for those footprints. We compared the time an eagle was found in the sample plots with the time it was found in the project footprint using a metric we called “error due to sampling”. Error due to sampling for individual eagles appeared to be influenced by interactions between the size of the project footprint (20, 40, 90 or 180 km2) and the sampling type (random, systematic or stratified) and was greatest on 90 km2 plots. However, use of random sampling resulted in lowest error due to sampling within intermediate sized plots. In addition sampling intensity and sampling frequency both influenced the effectiveness of point count sampling. Although our work focuses on individual eagles (not the eagle populations typically surveyed in the field), our analysis shows both the utility of simulations to identify specific influences on error and also potential improvements to sampling that consider the context-specific manner that point counts are laid out on the landscape.

  8. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peronio, P.; Acconcia, G.; Rech, I.

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach basedmore » on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.« less

  9. Bi-photon spectral correlation measurements from a silicon nanowire in the quantum and classical regimes

    PubMed Central

    Jizan, Iman; Helt, L. G.; Xiong, Chunle; Collins, Matthew J.; Choi, Duk-Yong; Joon Chae, Chang; Liscidini, Marco; Steel, M. J.; Eggleton, Benjamin J.; Clark, Alex S.

    2015-01-01

    The growing requirement for photon pairs with specific spectral correlations in quantum optics experiments has created a demand for fast, high resolution and accurate source characterisation. A promising tool for such characterisation uses classical stimulated processes, in which an additional seed laser stimulates photon generation yielding much higher count rates, as recently demonstrated for a χ(2) integrated source in A. Eckstein et al. Laser Photon. Rev. 8, L76 (2014). In this work we extend these results to χ(3) integrated sources, directly measuring for the first time the relation between spectral correlation measurements via stimulated and spontaneous four wave mixing in an integrated optical waveguide, a silicon nanowire. We directly confirm the speed-up due to higher count rates and demonstrate that this allows additional resolution to be gained when compared to traditional coincidence measurements without any increase in measurement time. As the pump pulse duration can influence the degree of spectral correlation, all of our measurements are taken for two different pump pulse widths. This allows us to confirm that the classical stimulated process correctly captures the degree of spectral correlation regardless of pump pulse duration, and cements its place as an essential characterisation method for the development of future quantum integrated devices. PMID:26218609

  10. Composition of diets selected by Sitka black-tailed deer on Channel Island, central southeast Alaska

    Treesearch

    Thomas A. Hanley; Michael P. Gillingham; Katherine L. Parker

    2014-01-01

    Composition of diets selected by tame but free-ranging deer in a natural forest environment was studied throughout a 24-month period and summarized by mean monthly percentage composition on the basis of dry-matter intake. A modifi cation of the standard bite-count method of diet determination was used. All forages were identifi ed by species and plant part (leaf, twig...

  11. Lytic resistance of fibrin containing red blood cells

    PubMed Central

    Wohner, Nikolett; Sótonyi, Péter; Machovich, Raymund; Szabó, László; Tenekedjiev, Kiril; Silva, Marta M.C.G.; Longstaff, Colin; Kolev, Krasimir

    2012-01-01

    Objective Arterial thrombi contain variable amounts of red blood cell (RBC), which interact with fibrinogen through an eptifibatide-sensitive receptor and modify the structure of fibrin. Here we evaluate the modulator role of RBCs in the lytic susceptibility of fibrin. Methods and Results If fibrin is formed at increasing RBC counts, scanning electron microscopy evidenced a decrease in fiber diameter from 150 nm to 96 nm at 40 %(v/v) RBC, an effect susceptible to eptifibatide inhibition (restoring 140 nm diameter). RBC prolonged the lysis time in a homogeneous-phase fibrinolytic assay with tissue plasminogen activator (tPA) by up to 22.7±1.6 %, but not in the presence of eptifibatide. Confocal laser microscopy using green fluorescent protein (GFP)-labeled tPA and orange fluorescent fibrin showed that 20-40 %(v/v) RBC significantly slowed down the dissolution of the clots. tPA-GFP did not accumulate on the surface of fibrin containing RBC at any cell count above 10 %. The presence of RBC in the clot suppressed the tPA-induced plasminogen activation resulting in a 45 % less plasmin generated after 30 min activation at 40 %(v/v) RBC. Conclusion RBCs confer lytic resistance to fibrin resulting from modified fibrin structure and impaired plasminogen activation through a mechanism that involves eptifibatide-sensitive fibrinogen-RBC interactions. PMID:21737785

  12. The Effect of Modified Atmosphere Packaging and Addition of Rosemary Extract, Sodium Acetate and Calcium Lactate Mixture on the Quality of Pre-cooked Hamburger Patties during Refrigerated Storage

    PubMed Central

    Muhlisin; Kang, Sun Moon; Choi, Won Hee; Lee, Keun Taik; Cheong, Sung Hee; Lee, Sung Ki

    2013-01-01

    The effect of modified atmosphere packaging (MAP; 30% CO2+70% N2 or 100% N2) and an additive mixture (500 ppm rosemary extract, 3,000 ppm sodium acetate and 1,500 ppm calcium lactate) on the quality of pre-cooked hamburger patties during storage at 5°C for 14 d was evaluated. The addition of the additive mixture reduced aerobic and anaerobic bacteria counts in both 30% CO2-MAP (30% CO2+70% N2) and 100% N2-MAP (p<0.05). The 30% CO2-MAP was more effective to suppress the microbial growth than 100% N2-MAP, moreover the 30% CO2-MAP combined with additive mixture resulted in the lowest bacterial counts. The hamburger patties with additive mixture showed lower CIE L* and CIE a*, and higher CIE b* than those with no additive mixture. The 30% CO2-MAP tended to decrease the TBARS during storage regardless of the addition of additives. The use of 30% CO2-MAP in combination with additives mixture was effective for maintaining the quality and extending the shelf-life of pre-cooked hamburger patties. PMID:25049716

  13. The growth of Listeria monocytogenes in cheese packed under a modified atmosphere.

    PubMed

    Whitley, E; Muir, D; Waites, W M

    2000-01-01

    The effect of modified atmosphere Packaging (MAP) on the growth of Listeria monocytogenes in mould ripened cheeses was studied at refrigeration temperatures (2-8.3 degrees C) over a storage period of 6 weeks. Control experiments in cling film with no atmospheric modification produced a lag time before growth of up to 1 week and rapid subsequent growth. MAP with a CO2 concentration of less than 20% allowed growth to occur but when O2 was incorporated; the lag time was reduced from 3 to 2 weeks and subsequent growth was also faster, producing an increase in cell numbers of 1.4 log cycles over the incubation period. N2-MAP in the absence of O2 increased the lag time to 3 weeks and slowed growth, while the inclusion of CO2 extended the lag to 3 weeks and slowed subsequent growth even more. In MAP with 80:10:10 (v/v/v) N2:CO2:O2, there was a lag period of 2-3 weeks before growth of L. monocytogenes occurred, while the total viable aerobic count (TVAC) decreased by 2-3 log cycles and the total Lactobacillus count showed little change. It was concluded that MAP was not suitable for preventing the growth of L. monocytogenes in such cheeses.

  14. Comparison of education and balneotherapy efficacy in patients with fibromyalgia syndrome: A randomized, controlled clinical study.

    PubMed

    Koçyiğit, Burhan Fatih; Gür, Ali; Altındağ, Özlem; Akyol, Ahmet; Gürsoy, Savaş

    2016-04-01

    Fibromyalgia is a disease characterized by chronic, widespread pain. Pharmacological and non-pharmacological treatment methods are used. The aim of the present study was to determine the effect of balneotherapy on treatment of fibromyalgia syndrome, compared with education alone. A total of 66 patients diagnosed with fibromyalgia syndrome were randomly separated into balneotherapy and control groups. Patients in both groups were informed about fibromyalgia syndrome. In addition, the balneotherapy group received 21 sessions of spa treatment with 34.8 °C thermomineral water, attending the spa 5 days a week. Patients were evaluated by visual analogue scale, tender point count, fibromyalgia impact questioning, and modified fatigue impact scale at initiation of treatment on the 15th day, 1st month, 3rd month, and 6th month. Evaluations were performed by the same doctor. Statistically significant improvement was detected in all parameters, compared to starting evaluation, in both groups. Most improved results among all parameters were observed in the balneotherapy group on the first 3-month follow-up. In addition, all parameters beyond tender point count and modified fatigue impact were improved on 6-month follow-up. It was concluded that addition of balneotherapy to patient education has both short- and long-term beneficial effects on female patients with fibromyalgia.

  15. MCNP-REN - A Monte Carlo Tool for Neutron Detector Design Without Using the Point Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abhold, M.E.; Baker, M.C.

    1999-07-25

    The development of neutron detectors makes extensive use of the predictions of detector response through the use of Monte Carlo techniques in conjunction with the point reactor model. Unfortunately, the point reactor model fails to accurately predict detector response in common applications. For this reason, the general Monte Carlo N-Particle code (MCNP) was modified to simulate the pulse streams that would be generated by a neutron detector and normally analyzed by a shift register. This modified code, MCNP - Random Exponentially Distributed Neutron Source (MCNP-REN), along with the Time Analysis Program (TAP) predict neutron detector response without using the pointmore » reactor model, making it unnecessary for the user to decide whether or not the assumptions of the point model are met for their application. MCNP-REN is capable of simulating standard neutron coincidence counting as well as neutron multiplicity counting. Measurements of MOX fresh fuel made using the Underwater Coincidence Counter (UWCC) as well as measurements of HEU reactor fuel using the active neutron Research Reactor Fuel Counter (RRFC) are compared with calculations. The method used in MCNP-REN is demonstrated to be fundamentally sound and shown to eliminate the need to use the point model for detector performance predictions.« less

  16. Immature pea seeds: effect of storage under modified atmosphere packaging and sanitation with acidified sodium chlorite.

    PubMed

    Collado, Elena; Venzke Klug, Tâmmila; Martínez-Sánchez, Ascensión; Artés-Hernandez, Francisco; Aguayo, Encarna; Artés, Francisco; Fernández, Juan A; Gómez, Perla A

    2017-10-01

    Appropriate sanitation is a priority for extending the shelf life and promoting the consumption of immature pea seeds, as processing accelerates quality deterioration and microbial growth. The combined effect of disinfection with acidified sodium chlorite (ASC) or sodium hypochlorite (SH) and packaging under a passive modified atmosphere (MAP) at 1 or 4 °C on quality was analysed. After 14 days, greenness and vitamin C had decreased, especially in the SH-disinfected samples. Total phenols and antioxidant capacity were not affected by disinfection. Proteins levels fell by around 27%, regardless of the sanitizer and storage temperature. Compared with the initial microbial load, samples stored at 1 °C showed an increase of 1 log CFU g -1 in psychrophiles when treated with SH, whereas no increase of note occurred with ASC. In general, microbial counts were always below 3 log CFU g -1 for all the treatments. Immature pea seeds could be stored for 14 days at 1-4 °C under MAP with only minor quality changes. Disinfection with ASC resulted in better sensory quality, higher content of vitamin C and lower psychrophile counts. More research is needed to analyse the effect of these treatments on other quality parameters. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. One year duration of immunity of the modified live bovine viral diarrhea virus type 1 and type 2 and bovine herpesvirus-1 fractions of Vista® Once SQ vaccine.

    PubMed

    Purtle, Lisa; Mattick, Debra; Schneider, Corey; Smith, Linda; Xue, Wenzhi; Trigo, Emilio

    2016-03-18

    Three studies were performed to determine the duration of immunity of the bovine viral diarrhea virus type 1 and type 2 (BVDV-1 and BVDV-2) and bovine herpesvirus-1 (BHV-1) fractions of a commercially prepared modified-live vaccine. Vista® Once SQ (Vista®) vaccine contains five modified-live viruses, BVDV-1, BVDV-2, BHV-1, bovine respiratory syncytial virus, and bovine parainfluenza 3 virus, and two modified-live bacteria, Pasteurella multocida and Mannheimia haemolytica. For all three studies, calves were administered a single dose of vaccine or placebo vaccine subcutaneously, and were challenged with one of the three virulent viruses at least one year following vaccination. Calves were evaluated daily following challenge for clinical signs of disease associated with viral infection, nasal swab samples were evaluated for virus shedding, and serum was tested for neutralizing antibodies. Following the BVDV-1 and BVDV-2 challenges, whole blood was evaluated for white blood cell counts, and for the BVDV-2 study, whole blood was also evaluated for platelet counts. Calves vaccinated with BVDV type 1a, were protected from challenge with BVDV type 1b, and had significant reductions in clinical disease, fever, leukopenia, and virus shedding compared to control calves. Vaccinated calves in the BVDV-2 study were protected from clinical disease, mortality, fever, leukopenia, thrombocytopenia, and virus shedding compared to controls. Vaccinated calves in the BHV-1 study were protected from clinical disease and fever, and had significantly reduced duration of nasal virus shedding. These three studies demonstrated that a single administration of the Vista® vaccine to healthy calves induces protective immunity against BVDV-1, BVDV-2 and BHV-1 that lasts at least one year following vaccination. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Immunotoxicological evaluation of wheat genetically modified with TaDREB4 gene on BALB/c mice.

    PubMed

    Liang, Chun Lai; Zhang, Xiao Peng; Song, Yan; Jia, Xu Dong

    2013-08-01

    To evaluate the immunotoxicological effects of genetically modified wheat with TaDREB4 gene in female BALB/c mice. Female mice weighing 18-22 g were divided into five groups (10 mice/group), which were set as negative control group, common wheat group, parental wheat group, genetically modified wheat group and cyclophosphamide positive control group, respectively. Mice in negative control group and positive control group were fed with AIN93G diet, mice in common wheat group, non-genetically modified parental wheat group and genetically modified wheat group were fed with feedstuffs added corresponding wheat (the proportion is 76%) for 30 days, then body weight, absolute and relative weight of spleen and thymus, white blood cell count, histological examination of immune organ, peripheral blood lymphocytes phenotyping, serum cytokine, serum immunoglobulin, antibody plaque-forming cell, serum half hemolysis value, mitogen-induced splenocyte proliferation, delayed-type hypersensitivity reaction and phagocytic activities of phagocytes were detected. No immunotoxicological effects related to the consumption of the genetically modified wheat were observed in BALB/c mice when compared with parental wheat group, common wheat group and negative control group. From the immunotoxicological point of view, results from this study demonstrate that genetically modified wheat with TaDREB4 gene is as safe as the parental wheat. Copyright © 2013 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  19. Performance characteristics of dedicated molecular breast imaging systems at low doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Zaiyang; Conners, Amy L.; Hunt, Katie N.

    Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assessmore » lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.« less

  20. Comparison of mixed-mode stress-intensity factors obtained through displacement correlation, J-integral formulation, and modified crack-closure integral

    NASA Astrophysics Data System (ADS)

    Bittencourt, Tulio N.; Barry, Ahmabou; Ingraffea, Anthony R.

    This paper presents a comparison among stress-intensity factors for mixed-mode two-dimensional problems obtained through three different approaches: displacement correlation, J-integral, and modified crack-closure integral. All mentioned procedures involve only one analysis step and are incorporated in the post-processor page of a finite element computer code for fracture mechanics analysis (FRANC). Results are presented for a closed-form solution problem under mixed-mode conditions. The accuracy of these described methods then is discussed and analyzed in the framework of their numerical results. The influence of the differences among the three methods on the predicted crack trajectory of general problems is also discussed.

  1. Entrococcus faecalis Elimination in Root Canals Using Silver Nanoparticles, Photodynamic Therapy, Diode Laser, or Laser-activated Nanoparticles: An In Vitro Study.

    PubMed

    Afkhami, Farzaneh; Akbari, Saba; Chiniforush, Nasim

    2017-02-01

    The aim of this study was to compare the efficacy of silver nanoparticles (AgNPs), an 810-nm diode laser (DL), conventional photodynamic therapy (PDT) with the use of indocyanine green (ICG) photosensitizer, and modified PDT with the use of AgNPs for the disinfection of root canals inoculated with Enterococcus faecalis. The root canals of 65 extracted human single-rooted teeth were prepared, and E. faecalis was incubated in the root canals for 4 weeks. The teeth were then randomly divided into the following 4 experimental groups: the DL group: 810-nm DL irradiation (1 W, 4 times for 10 seconds), the AN group: 5 minutes of irrigation with 5 mL AgNPs (100 ppm), the ICG/DL group: conventional PDT with ICG (1 mg/mL)/810-nm DL (200 mW, 30 seconds), and the AN/ICG/DL group: modified PDT with AgNPs/ICG/810-nm DL (200 mW, 30 seconds). There was also a control group, which consisted of 5 minutes of irrigation with 5 mL 2.5% sodium hypochlorite (n = 9). Samples were obtained from dentin chips before and after the interventions. A reduction in colony count was assessed by counting the colony-forming units. Significant reductions were noted in E. faecalis colony counts in all groups (P < .05). The greatest reduction in colony count (99.12%) was noted in the AN/ICG/DL group (AgNPs/ICG/810-nm diode laser); however, the differences in this respect between the AN/ICG/DL group and the DL (97.41%), AN (94.42%), and control groups (94.61%) were not significant (P > .05). PDT with ICG, an 810-nm diode laser, and AgNPs has the potential to be used as an adjunct for disinfection of the root canal system. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Responses of Escherichia coli, Listeria monocytogenes, and Staphylococcus aureus to Simulated Food Processing Treatments, Determined Using Fluorescence-Activated Cell Sorting and Plate Counting▿

    PubMed Central

    Kennedy, Deirdre; Cronin, Ultan P.; Wilkinson, Martin G.

    2011-01-01

    Three common food pathogenic microorganisms were exposed to treatments simulating those used in food processing. Treated cell suspensions were then analyzed for reduction in growth by plate counting. Flow cytometry (FCM) and fluorescence-activated cell sorting (FACS) were carried out on treated cells stained for membrane integrity (Syto 9/propidium iodide) or the presence of membrane potential [DiOC2(3)]. For each microbial species, representative cells from various subpopulations detected by FCM were sorted onto selective and nonselective agar and evaluated for growth and recovery rates. In general, treatments giving rise to the highest reductions in counts also had the greatest effects on cell membrane integrity and membrane potential. Overall, treatments that impacted cell membrane permeability did not necessarily have a comparable effect on membrane potential. In addition, some bacterial species with extensively damaged membranes, as detected by FCM, appeared to be able to replicate and grow after sorting. Growth of sorted cells from various subpopulations was not always reflected in plate counts, and in some cases the staining protocol may have rendered cells unculturable. Optimized FCM protocols generated a greater insight into the extent of the heterogeneous bacterial population responses to food control measures than did plate counts. This study underlined the requirement to use FACS to relate various cytometric profiles generated by various staining protocols with the ability of cells to grow on microbial agar plates. Such information is a prerequisite for more-widespread adoption of FCM as a routine microbiological analytical technique. PMID:21602370

  3. Comparison of Three Bed Bug Management Strategies in a Low-Income Apartment Building.

    PubMed

    Wang, Changlu; Saltzmann, Kurt; Bennett, Gary; Gibb, Timothy

    2012-04-02

    Bed bug (Cimex lectularius L.) infestations are currently controlled by a variety of non-chemical and chemical methods. There have been few studies on the comparative effectiveness of these control techniques. We evaluated three bed bug management strategies in an apartment building: (1) non-chemical methods only (n = 9); (2) insecticides only (n = 6); and (3) integrated pest management including both non-chemical methods and insecticides (n = 9). The apartments were one-bedroom units occupied by seniors or people with disabilities. Bed bug numbers in each apartment were determined by visual inspection and/or installing intercepting devices under bed and sofa legs. The median (min, max) bed bug counts in the non-chemical methods only, insecticides only, and integrated pest management (IPM) treatment were: 4 (1, 57), 19 (1, 250), and 14 (1, 219), respectively prior to the treatments. The apartments were retreated if found necessary during biweekly to monthly inspections. After 10 weeks, bed bugs were found to be eliminated from 67, 33, and 44% of the apartments in the three treatment groups, respectively. The final (after 10 weeks) median (min, max) bed bug counts in the non-chemical methods only, insecticides only, and IPM treatment were: 0 (0, 134), 11.5 (0, 58), and 1 (0, 38), respectively. There were no significant differences in the speed of bed bug count reduction or the final bed bug counts. Lack of resident cooperation partially contributed to the failure in eliminating bed bugs from some of the apartments. Results of this study suggest that non-chemical methods can effectively eliminate bed bugs in lightly infested apartments.

  4. Stateless and stateful implementations of faithful execution

    DOEpatents

    Pierson, Lyndon G; Witzke, Edward L; Tarman, Thomas D; Robertson, Perry J; Eldridge, John M; Campbell, Philip L

    2014-12-16

    A faithful execution system includes system memory, a target processor, and protection engine. The system memory stores a ciphertext including value fields and integrity fields. The value fields each include an encrypted executable instruction and the integrity fields each include an encrypted integrity value for determining whether a corresponding one of the value fields has been modified. The target processor executes plaintext instructions decoded from the ciphertext while the protection engine is coupled between the system memory and the target processor. The protection engine includes logic to retrieve the ciphertext from the system memory, decrypt the value fields into the plaintext instructions, perform an integrity check based on the integrity fields to determine whether any of the corresponding value fields have been modified, and provide the plaintext instructions to the target processor for execution.

  5. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    NASA Technical Reports Server (NTRS)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  6. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, A K; Koniczek, M; Antonuk, L E

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailedmore » circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.« less

  7. An integrated modeling approach to estimating Gunnison Sage-Grouse population dynamics: combining index and demographic data.

    USGS Publications Warehouse

    Davis, Amy J.; Hooten, Mevin B.; Phillips, Michael L.; Doherty, Paul F.

    2014-01-01

    Evaluation of population dynamics for rare and declining species is often limited to data that are sparse and/or of poor quality. Frequently, the best data available for rare bird species are based on large-scale, population count data. These data are commonly based on sampling methods that lack consistent sampling effort, do not account for detectability, and are complicated by observer bias. For some species, short-term studies of demographic rates have been conducted as well, but the data from such studies are typically analyzed separately. To utilize the strengths and minimize the weaknesses of these two data types, we developed a novel Bayesian integrated model that links population count data and population demographic data through population growth rate (λ) for Gunnison sage-grouse (Centrocercus minimus). The long-term population index data available for Gunnison sage-grouse are annual (years 1953–2012) male lek counts. An intensive demographic study was also conducted from years 2005 to 2010. We were able to reduce the variability in expected population growth rates across time, while correcting for potential small sample size bias in the demographic data. We found the population of Gunnison sage-grouse to be variable and slightly declining over the past 16 years.

  8. A case for using Plethodontid salamanders for monitoring biodiversity and ecosystem integrity of North American forests

    USGS Publications Warehouse

    Welsh, H.H.; Droege, S.

    2001-01-01

    Terrestrial salamanders of the family P!ethodontidae have unique attributes that make them excellent indicators of biodiversity and ecosystem integrity in forested habitats. Their longevity, small territory size, site fidelity, sensitivity to natural and anthropogenic perturbations, tendency to occur in high densities, and low sampling costs mean that counts of plethodontid salamanders provide numerous advantages over counts of other North American forest organisms for indicating environmental change. Furthermore, they are tightly linked physiologically to microclimatic and successional processes that influence the distribution and abundance of numerous other hydrophilic but difficult-to-study forest-dwelling plants and animals. Ecosystem processes such as moisture cycling, food-web dynamics, and succession, with their related structural and microclimatic variability, all affect forest biodiversity and have been shown to affect salamander populations as well. We determined the variability associated with sampling for plethodontid salamanders by estimating the coefficient of variation (CV) from available time-series data. The median coefficient of variation indicated that variation in counts of individuals among studies was much lower in plethodonticis (27%) than in lepidoptera (93%), passerine birds (57%), small mammals (69%), or other amphibians (37-46%), which means plethodontid salamanders provide an important statistical advantage over other species for monitoring long-term forest health.

  9. Longitudinal effect of CD4 by cotrimoxazole use on malaria incidence among HIV-infected Ugandan adults on antiretroviral therapy: a randomized controlled study.

    PubMed

    Kasirye, Ronnie; Grosskurth, Heiner; Munderi, Paula; Levin, Jonathan; Anywaine, Zacchaeus; Nunn, Andrew; Kamali, Anatoli; Baisley, Kathy

    2016-07-15

    The effect of CD4 count on malaria incidence in HIV infected adults on antiretroviral therapy (ART) was assessed in the context of a randomized controlled trial on the effect of stopping cotrimoxazole (CTX). This study presents a sub-analysis of the COSTOP trial (ISRCTN44723643) which was carried out among HIV-infected Ugandan adults stable on ART with CD4 counts ≥250 cells/µl. Participants were randomized (1:1) to continue CTX or stop CTX and receive matching placebo, and were followed up for a minimum of 1 year (median 2.5 years). CD4 counts were measured at baseline, 3 months and then every 6 months. Clinical malaria was defined as fever and a positive blood slide. First, the relationship between current CD4 count during follow-up and malaria among participants on placebo was examined; using random effects Poisson regression to account for repeated episodes. Second, the effect of CD4 count at enrolment, CD4 count at ART initiation, and CD4 count during follow-up on malaria, was assessed within each trial arm; to examine whether the effect of CD4 count differed by CTX use. 2180 participants were enrolled into the COSTOP trial. The incidence of clinical malaria was approximately four episodes/100 person years in the CTX arm and 14 episodes/100 person years in the placebo arm. There was no evidence of an association of current CD4 and clinical malaria incidence (P = 0.56), or parasitaemia levels (P = 0.24), in the placebo arm. Malaria incidence did not differ by CD4 count at ART initiation, enrolment or during follow up, irrespective of CTX use. When compared with participants in the lowest CD4 stratum, rate ratios within each trial arm were all close to 1, and P values were all above P = 0.30. The immune status of HIV infected participants who are stable on ART as measured by CD4 count was not associated with malaria incidence and did not modify the effect of stopping CTX on malaria. The decision of whether to stop or continue CTX prophylaxis for malaria in HIV infected individuals who are stable on ART should not be based on CD4 counts alone. COSTOP trial registration number ISRCTN44723643.

  10. Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting

    PubMed Central

    Huang, Xiwei; Jiang, Yu; Liu, Xu; Xu, Hang; Han, Zhi; Rong, Hailong; Yang, Haiping; Yan, Mei; Yu, Hao

    2016-01-01

    A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS) image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT). However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR) processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR) and Convolutional Neural Network based SR (CNNSR). Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications. PMID:27827837

  11. In vivo macular pigment measurements: a comparison of resonance Raman spectroscopy and heterochromatic flicker photometry

    PubMed Central

    Hogg, R E; Anderson, R S; Stevenson, M R; Zlatkova, M B; Chakravarthy, U

    2007-01-01

    Aim To investigate whether two methods of measuring macular pigment—namely, heterochromatic flicker photometry (HFP) and resonance Raman spectroscopy (RRS)—yield comparable data. Methods Macular pigment was measured using HFP and RRS in the right eye of 107 participants aged 20–79 years. Correlations between methods were sought and regression models generated. RRS was recorded as Raman counts and HFP as macular pigment optical density (MPOD). The average of the top three of five Raman counts was compared with MPOD obtained at 0.5° eccentricity, and an integrated measure (spatial profile; MPODsp) computed from four stimulus sizes on HFP. Results The coefficient of variation was 12.0% for MPODsp and 13.5% for Raman counts. MPODsp exhibited significant correlations with Raman counts (r = 0.260, p = 0.012), whereas MPOD at 0.5° did not correlate significantly (r = 0.163, p = 0.118). MPODsp was not significantly correlated with age (p = 0.062), whereas MPOD at 0.5° was positively correlated (p = 0.011). Raman counts showed a significant decrease with age (p = 0.002) and were significantly lower when pupil size was smaller (p = 0.015). Conclusions Despite a statistically significant correlation, the correlations were weak, with those in excess of 90% of the variance between MPODsp and Raman counts remaining unexplained, meriting further research. PMID:16825281

  12. Analysis of a turbulent boundary layer over a moving ground plane

    NASA Technical Reports Server (NTRS)

    Roper, A. T.; Gentry, G. L., Jr.

    1972-01-01

    Four methods of predicting the integral and friction parameters for a turbulent boundary layer over a moving ground plane were evaluated by using test information obtained in 76.2- by 50.8-centimeter tunnel. The tunnel was operated in the open sidewall configuration. These methods are (1) relative integral parameter method, (2) modified power law method, (3) relative power law method, and (4) modified law of the wall method. The modified law of the wall method predicts a more rapid decrease in skin friction with an increase in the ratio of belt velocity to free steam velocity than do methods (1) and (3).

  13. Fully integrated sub 100ps photon counting platform

    NASA Astrophysics Data System (ADS)

    Buckley, S. J.; Bellis, S. J.; Rosinger, P.; Jackson, J. C.

    2007-02-01

    Current state of the art high resolution counting modules, specifically designed for high timing resolution applications, are largely based on a computer card format. This has tended to result in a costly solution that is restricted to the computer it resides in. We describe a four channel timing module that interfaces to a computer via a USB port and operates with a resolution of less than 100 picoseconds. The core design of the system is an advanced field programmable gate array (FPGA) interfacing to a precision time interval measurement module, mass memory block and a high speed USB 2.0 serial data port. The FPGA design allows the module to operate in a number of modes allowing both continuous recording of photon events (time-tagging) and repetitive time binning. In time-tag mode the system reports, for each photon event, the high resolution time along with the chronological time (macro time) and the channel ID. The time-tags are uploaded in real time to a host computer via a high speed USB port allowing continuous storage to computer memory of up to 4 millions photons per second. In time-bin mode, binning is carried out with count rates up to 10 million photons per second. Each curve resides in a block of 128,000 time-bins each with a resolution programmable down to less than 100 picoseconds. Each bin has a limit of 65535 hits allowing autonomous curve recording until a bin reaches the maximum count or the system is commanded to halt. Due to the large memory storage, several curves/experiments can be stored in the system prior to uploading to the host computer for analysis. This makes this module ideal for integration into high timing resolution specific applications such as laser ranging and fluorescence lifetime imaging using techniques such as time correlated single photon counting (TCSPC).

  14. Counts, serovars, and antimicrobial resistance phenotypes of Salmonella on raw chicken meat at retail in Colombia.

    PubMed

    Donado-Godoy, Pilar; Clavijo, Viviana; León, Maribel; Arevalo, Alejandra; Castellanos, Ricardo; Bernal, Johan; Tafur, Mc Allister; Ovalle, Maria Victoria; Alali, Walid Q; Hume, Michael; Romero-Zuñiga, Juan Jose; Walls, Isabel; Doyle, Michael P

    2014-02-01

    The objective of this study was to determine Salmonella counts, serovars, and antimicrobial-resistant phenotypes on retail raw chicken carcasses in Colombia. A total of 301 chicken carcasses were collected from six departments (one city per department) in Colombia. Samples were analyzed for Salmonella counts using the most-probable-number method as recommended by the U.S. Department of Agriculture, Food Safety Inspection Service protocol. A total of 378 isolates (268 from our previous study) were serotyped and tested for antimicrobial susceptibility. The overall Salmonella count (mean log most probable number per carcass ± 95% confidence interval) and prevalence were 2.1 (2.0 to 2.3) and 37%, respectively. There were significant differences (P < 0.05) by Salmonella levels (i.e., counts and prevalence) by storage temperature (i.e., frozen, chilled, or ambient), retail store type (wet markets, supermarkets, and independent markets), and poultry company (chicken produced by integrated or nonintegrated company). Frozen chicken had the lowest Salmonella levels compared with chicken stored at other temperatures, chickens from wet markets had higher levels than those from other retail store types, and chicken produced by integrated companies had lower levels than nonintegrated companies. Thirty-one Salmonella serovars were identified among 378 isolates, with Salmonella Paratyphi B tartrate-positive (i.e., Salmonella Paratyphi B dT+) the most prevalent (44.7%), followed by Heidelberg (19%), Enteritidis (17.7%), Typhimurium (5.3%), and Anatum (2.1%). Of all the Salmonella isolates, 35.2% were resistant to 1 to 5 antimicrobial agents, 24.6% to 6 to 10, and 33.9% to 11 to 15. Among all the serovars obtained, Salmonella Paratyphi B dT+ and Salmonella Heidelberg were the most antimicrobial resistant. Salmonella prevalence was determined to be high, whereas cell numbers were relatively low. These data can be used in developing risk assessment models for preventing the transmission of Salmonella from chicken to humans in Colombia.

  15. An accurate derivation of the air dose-rate and the deposition concentration distribution by aerial monitoring in a low level contaminated area

    NASA Astrophysics Data System (ADS)

    Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo

    2015-04-01

    Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.

  16. SU-F-SPS-09: Parallel MC Kernel Calculations for VMAT Plan Improvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamberlain, S; Roswell Park Cancer Institute, Buffalo, NY; French, S

    Purpose: Adding kernels (small perturbations in leaf positions) to the existing apertures of VMAT control points may improve plan quality. We investigate the calculation of kernel doses using a parallelized Monte Carlo (MC) method. Methods: A clinical prostate VMAT DICOM plan was exported from Eclipse. An arbitrary control point and leaf were chosen, and a modified MLC file was created, corresponding to the leaf position offset by 0.5cm. The additional dose produced by this 0.5 cm × 0.5 cm kernel was calculated using the DOSXYZnrc component module of BEAMnrc. A range of particle history counts were run (varying from 3more » × 10{sup 6} to 3 × 10{sup 7}); each job was split among 1, 10, or 100 parallel processes. A particle count of 3 × 10{sup 6} was established as the lower range because it provided the minimal accuracy level. Results: As expected, an increase in particle counts linearly increases run time. For the lowest particle count, the time varied from 30 hours for the single-processor run, to 0.30 hours for the 100-processor run. Conclusion: Parallel processing of MC calculations in the EGS framework significantly decreases time necessary for each kernel dose calculation. Particle counts lower than 1 × 10{sup 6} have too large of an error to output accurate dose for a Monte Carlo kernel calculation. Future work will investigate increasing the number of parallel processes and optimizing run times for multiple kernel calculations.« less

  17. Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy.

    PubMed

    Eghrari, Allen O; Mumtaz, Aisha A; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S; Riazuddin, S Amer; Gottsch, John D

    2017-01-01

    Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870-0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797-0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.

  18. Automated retroillumination photography analysis for objective assessment of Fuchs Corneal Dystrophy severity

    PubMed Central

    Eghrari, Allen O.; Mumtaz, Aisha A.; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S.; Riazuddin, S. Amer; Gottsch, John D.

    2016-01-01

    Purpose Retroillumination photography analysis (RPA) is an objective tool for assessment of the number and distribution of guttae in eyes affected with Fuchs Corneal Dystrophy (FCD). Current protocols include manual processing of images; here we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Methods Retroillumination photographs of 97 FCD-affected corneas were acquired and total counts of guttae previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. Results A set of 97 retroillumination photographs were analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R2=0.79) and manual counts (R2=0.88). Intraclass correlation coefficient demonstrated strong correlation, at 0.924 (95% CI, 0.870- 0.958) among cases analyzed by three students, and 0.869 (95% CI, 0.797- 0.918) among cases for which images was analyzed by an ophthalmologist and two students. Conclusions Automated RPA allows for grading of FCD severity with high resolution across a spectrum of disease severity. PMID:27811565

  19. Absolute dose calibration of an X-ray system and dead time investigations of photon-counting techniques

    NASA Astrophysics Data System (ADS)

    Carpentieri, C.; Schwarz, C.; Ludwig, J.; Ashfaq, A.; Fiederle, M.

    2002-07-01

    High precision concerning the dose calibration of X-ray sources is required when counting and integrating methods are compared. The dose calibration for a dental X-ray tube was executed with special dose calibration equipment (dosimeter) as function of exposure time and rate. Results were compared with a benchmark spectrum and agree within ±1.5%. Dead time investigations with the Medipix1 photon-counting chip (PCC) have been performed by rate variations. Two different types of dead time, paralysable and non-paralysable will be discussed. The dead time depends on settings of the front-end electronics and is a function of signal height, which might lead to systematic defects of systems. Dead time losses in excess of 30% have been found for the PCC at 200 kHz absorbed photons per pixel.

  20. Integrating LMINET with TAAM and SIMMOD: A Feasibility Study

    NASA Technical Reports Server (NTRS)

    Long, Dou; Stouffer-Coston, Virginia; Kostiuk, Peter; Kula, Richard; Yackovetsky, Robert (Technical Monitor)

    2001-01-01

    LMINET is a queuing network air traffic simulation model implemented at 64 large airports and the entire National Airspace System in the United States. TAAM and SIMMOD are two widely used air traffic event-driven simulation models mostly for airports. Based on our proposed Progressive Augmented window approach, TAAM and SIMMOD are integrated with LMINET though flight schedules. In the integration, the flight schedules are modified through the flight delays reported by the other models. The benefit to the local simulation study is to let TAAM or SIMMOD take the modified schedule from LMINET, which takes into account of the air traffic congestion and flight delays at the national network level. We demonstrate the value of the integrated models by the case studies at Chicago O'Hare International Airport and Washington Dulles International Airport. Details of the integration are reported and future work for a full-blown integration is identified.

  1. Anomalous effects of radioactive decay rates and capacitance values measured inside a modified Faraday cage: Correlations with space weather

    NASA Astrophysics Data System (ADS)

    Scholkmann, F.; Milián-Sánchez, V.; Mocholí-Salcedo, A.; Milián, C.; Kolombet, V. A.; Verdú, G.

    2017-03-01

    Recently we reported (Milián-Sánchez V. et al., Nucl. Instrum. Methods A, 828 (2016) 210) our experimental results involving 226Ra decay rate and capacitance measurements inside a modified Faraday cage. Our measurements exhibited anomalous effects of unknown origin. In this letter we report new results regarding our investigation into the origins of the observed effects. We report preliminary findings of a correlation analysis between the radioactive decay rates and capacitance time series and space weather related variables (geomagnetic field disturbances and cosmic-ray neutron counts). A significant correlation was observed for specific data sets. The results are presented and possible implications for future work discussed.

  2. A Translational Worksite Diabetes Prevention Trial Improves Psychosocial Status, Dietary Intake, and Step Counts among Employees with Prediabetes: A Randomized Controlled Trial.

    PubMed

    Miller, Carla K; Weinhold, Kellie; Marrero, David G; Nagaraja, Haikady N; Focht, Brian C

    Few worksite trials have examined the impact of diabetes prevention interventions on psychological and behavioral outcomes. Thus, the impact of a worksite lifestyle intervention on psychosocial outcomes, food group intake, and step counts for physical activity (PA) was evaluated. A randomized pretest/posttest control group design with 3-month follow-up was employed from October 2012 to May 2014 at a U.S. university worksite among employees with prediabetes. The experimental group (n=35) received a 16-week group-based intervention while the control group received usual care (n=33). Repeated measures analysis of variance compared the change in outcomes between groups across time. A significant difference occurred between groups post-intervention for self-efficacy associated with eating and PA; goal commitment and difficulty; satisfaction with weight loss and physical fitness; peer social support for healthful eating; generation of alternatives for problem solving; and intake of fruits, meat, fish, poultry, nuts, and seeds (all ps < .05). The experimental group significantly increased step counts post-intervention (p = .0279) and were significantly more likely to report completing their work at study end (p = .0231). The worksite trial facilitated improvement in modifiable psychosocial outcomes, dietary patterns, and step counts; the long-term impact on diabetes prevention warrants further investigation. ClinicalTrials.gov identifier: NCT01682954.

  3. Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishikawa, M.; Shinohara, K.; Itoga, T.

    2008-03-12

    Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detectormore » are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.« less

  4. Verification of rain-flow reconstructions of a variable amplitude load history. M.S. Thesis, 1990 Final Report

    NASA Technical Reports Server (NTRS)

    Clothiaux, John D.; Dowling, Norman E.

    1992-01-01

    The suitability of using rain-flow reconstructions as an alternative to an original loading spectrum for component fatigue life testing is investigated. A modified helicopter maneuver history is used for the rain-flow cycle counting and history regenerations. Experimental testing on a notched test specimen over a wide range of loads produces similar lives for the original history and the reconstructions. The test lives also agree with a simplified local strain analysis performed on the specimen utilizing the rain-flow cycle count. The rain-flow reconstruction technique is shown to be a viable test spectrum alternative to storing the complete original load history, especially in saving computer storage space and processing time. A description of the regeneration method, the simplified life prediction analysis, and the experimental methods are included in the investigation.

  5. Improvement of the Scintillation-Irregularity Model in WBMOD

    DTIC Science & Technology

    1983-02-28

    satellite over e small s.ction of its orbit . 2-4 IMPLEMENTATION AT AFGWC One of the tasks carried out was to modify the most recent version of WaMOD...influence scintillation strength OSRTN Sets up integral to calculate phase variance, for finite outer scale ROMINT Modified Romberg quadrature integration... orbit calculation, and implc-Nentation of Ln irregularity drift routine based on a recently published model of ionospheric convection st high latitudes

  6. Modified retrieval algorithm for three types of precipitation distribution using x-band synthetic aperture radar

    NASA Astrophysics Data System (ADS)

    Xie, Yanan; Zhou, Mingliang; Pan, Dengke

    2017-10-01

    The forward-scattering model is introduced to describe the response of normalized radar cross section (NRCS) of precipitation with synthetic aperture radar (SAR). Since the distribution of near-surface rainfall is related to the rate of near-surface rainfall and horizontal distribution factor, a retrieval algorithm called modified regression empirical and model-oriented statistical (M-M) based on the volterra integration theory is proposed. Compared with the model-oriented statistical and volterra integration (MOSVI) algorithm, the biggest difference is that the M-M algorithm is based on the modified regression empirical algorithm rather than the linear regression formula to retrieve the value of near-surface rainfall rate. Half of the empirical parameters are reduced in the weighted integral work and a smaller average relative error is received while the rainfall rate is less than 100 mm/h. Therefore, the algorithm proposed in this paper can obtain high-precision rainfall information.

  7. Capturing the Integration of Practice-Based Learning with Beliefs, Values, and Attitudes using Modified Concept Mapping.

    PubMed

    Mcnaughton, Susan; Barrow, Mark; Bagg, Warwick; Frielick, Stanley

    2016-01-01

    Practice-based learning integrates the cognitive, psychomotor, and affective domains and is influenced by students' beliefs, values, and attitudes. Concept mapping has been shown to effectively demonstrate students' changing concepts and knowledge structures. This article discusses how concept mapping was modified to capture students' perceptions of the connections between the domains of thinking and knowing, emotions, behavior, attitudes, values, and beliefs and the specific experiences related to these, over a period of eight months of practice-based clinical learning. The findings demonstrate that while some limitations exist, modified concept mapping is a manageable way to gather rich data about students' perceptions of their clinical practice experiences. These findings also highlight the strong integrating influence of beliefs and values on other areas of practice, suggesting that these need to be attended to as part of a student's educational program.

  8. Capturing the Integration of Practice-Based Learning with Beliefs, Values, and Attitudes using Modified Concept Mapping

    PubMed Central

    Mcnaughton, Susan; Barrow, Mark; Bagg, Warwick; Frielick, Stanley

    2016-01-01

    Practice-based learning integrates the cognitive, psychomotor, and affective domains and is influenced by students’ beliefs, values, and attitudes. Concept mapping has been shown to effectively demonstrate students’ changing concepts and knowledge structures. This article discusses how concept mapping was modified to capture students’ perceptions of the connections between the domains of thinking and knowing, emotions, behavior, attitudes, values, and beliefs and the specific experiences related to these, over a period of eight months of practice-based clinical learning. The findings demonstrate that while some limitations exist, modified concept mapping is a manageable way to gather rich data about students’ perceptions of their clinical practice experiences. These findings also highlight the strong integrating influence of beliefs and values on other areas of practice, suggesting that these need to be attended to as part of a student's educational program. PMID:29349311

  9. Detector Design Considerations in High-Dimensional Artificial Immune Systems

    DTIC Science & Technology

    2012-03-22

    a method known as randomized RNS [15]. In this approach, Monte Carlo integration is used to determine the size of self and non-self within the given...feature space, then a number of randomly placed detectors are chosen according to Monte Carlo integration calculations. Simulated annealing is then...detector is only counted once). This value is termed ‘actual content’ because it does not including overlapping content, but only that content that is

  10. Radome Positioner for the RFSS (Radio Frequency Simulation System).

    DTIC Science & Technology

    1978-02-27

    its associated circuits contained on the Motorola M68MM01A-I micro- module (See Drawing 64). This board contains the 6800 microprocessor. Ik bytes of...D 00 1~ 0 41 + C.) ) -44 208 g. Small encoder diameter achieved by using integrated circuit modules . h. Stainless steel case. U...to the 30 integrated circuits which actually comprise the heart of the-microcomputer. This dramatic reduction in parts count re- sults in a similar

  11. Procedures for mastitis diagnosis and control.

    PubMed

    Sears, P M; González, R N; Wilson, D J; Han, H R

    1993-11-01

    Procedures for mastitis diagnosis and control include culturing individual cow and bulk tank milk samples, antibiotic susceptibility testing, and evaluation of somatic cell count reports and clinical mastitis treatment records. Integrated use of such procedures is necessary for effective mastitis diagnosis and control.

  12. Classroom Capsules.

    ERIC Educational Resources Information Center

    Page, Warren, Ed.

    1988-01-01

    Presents ideas that are intended to convey new insights on familiar topics and to enhance pedagogy. The mathematical topics addressed are applications of transformations to numerical integration, the golden ratio, Cramer's rule, a counting problem, and the general form of the arithmetic-geometric mean inequality. (PK)

  13. Design and construction of portable survey meter

    NASA Astrophysics Data System (ADS)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  14. The relative importance of intrinsic and extrinsic drivers to population growth vary among local populations of Greater Sage-Grouse: An integrated population modeling approach

    USGS Publications Warehouse

    Coates, Peter S.; Prochazka, Brian G.; Ricca, Mark A.; Halstead, Brian J.; Casazza, Michael L.; Blomberg, Erik J.; Brussee, Brianne E.; Wiechman, Lief; Tebbenkamp, Joel; Gardner, Scott C.; Reese, Kerry P.

    2018-01-01

    Consideration of ecological scale is fundamental to understanding and managing avian population growth and decline. Empirically driven models for population dynamics and demographic processes across multiple spatial scales can be powerful tools to help guide conservation actions. Integrated population models (IPMs) provide a framework for better parameter estimation by unifying multiple sources of data (e.g., count and demographic data). Hierarchical structure within such models that include random effects allow for varying degrees of data sharing across different spatiotemporal scales. We developed an IPM to investigate Greater Sage-Grouse (Centrocercus urophasianus) on the border of California and Nevada, known as the Bi-State Distinct Population Segment. Our analysis integrated 13 years of lek count data (n > 2,000) and intensive telemetry (VHF and GPS; n > 350 individuals) data across 6 subpopulations. Specifically, we identified the most parsimonious models among varying random effects and density-dependent terms for each population vital rate (e.g., nest survival). Using a joint likelihood process, we integrated the lek count data with the demographic models to estimate apparent abundance and refine vital rate parameter estimates. To investigate effects of climatic conditions, we extended the model to fit a precipitation covariate for instantaneous rate of change (r). At a metapopulation extent (i.e. Bi-State), annual population rate of change λ (er) did not favor an overall increasing or decreasing trend through the time series. However, annual changes in λ were driven by changes in precipitation (one-year lag effect). At subpopulation extents, we identified substantial variation in λ and demographic rates. One subpopulation clearly decoupled from the trend at the metapopulation extent and exhibited relatively high risk of extinction as a result of low egg fertility. These findings can inform localized, targeted management actions for specific areas, and status of the species for the larger Bi-State.

  15. Series expansion of the modified Einstein Procedure

    Treesearch

    Seema Chandrakant Shah-Fairbank

    2009-01-01

    This study examines calculating total sediment discharge based on the Modified Einstein Procedure (MEP). A new procedure based on the Series Expansion of the Modified Einstein Procedure (SEMEP) has been developed. This procedure contains four main modifications to MEP. First, SEMEP solves the Einstein integrals quickly and accurately based on a series expansion. Next,...

  16. Wastewater Management Alternatives for the Cleveland - Akron, Three Rivers Watershed Area. Technical Appendix - Phase II. System Design and Estimate of Cost.

    DTIC Science & Technology

    1973-02-01

    established. Secondly, the applicable process sequence to most economically meet these requirements under local enviromental constraints must be...concentrations are highest for receiving waters containing cold water fisheries. Allowable fecal coliform bacteria counts vary seasonally and dictate...handling system has also been modified to include gravity waste activated sludge thickening and heat conditioning of the combined raw sludge after

  17. Computing Maximum Likelihood Estimates of Loglinear Models from Marginal Sums with Special Attention to Loglinear Item Response Theory. [Project Psychometric Aspects of Item Banking No. 53.] Research Report 91-1.

    ERIC Educational Resources Information Center

    Kelderman, Henk

    In this paper, algorithms are described for obtaining the maximum likelihood estimates of the parameters in log-linear models. Modified versions of the iterative proportional fitting and Newton-Raphson algorithms are described that work on the minimal sufficient statistics rather than on the usual counts in the full contingency table. This is…

  18. Step It Up! Using the Good Behavior Game to Increase Physical Activity with Elementary School Students at Recess

    ERIC Educational Resources Information Center

    Galbraith, Leslie A.; Normand, Matthew P.

    2017-01-01

    We evaluated the effects of a modified version of the Good Behavior Game (GBG) on the number of steps taken by students during school recess. We divided a class into two teams, and awarded the team with the highest step counts at the end of each game raffle tickets for a school-wide lottery. The GBG was compared to recess periods without the game…

  19. Integrated Design Tools Reduce Risk, Cost

    NASA Technical Reports Server (NTRS)

    2012-01-01

    Thanks in part to a SBIR award with Langley Research Center, Phoenix Integration Inc., based in Wayne, Pennsylvania, modified and advanced software for process integration and design automation. For NASA, the tool has resulted in lower project costs and reductions in design time; clients of Phoenix Integration are experiencing the same rewards.

  20. Assessing the factorial structure and measurement invariance of PTSD by gender and ethnic groups in Sri Lanka: An analysis of the modified Harvard Trauma Questionnaire (HTQ).

    PubMed

    Tay, Alvin Kuowei; Jayasuriya, Rohan; Jayasuriya, Dinuk; Silove, Derrick

    2017-04-01

    The Harvard Trauma Questionnaire (HTQ) remains the most widely used screening measure for post-traumatic stress disorder (PTSD) in the refugee and post-conflict field. The present study is the first to test the factorial structure and measurement invariance of the HTQ according to DSM-5 criteria across gender and ethnic groups in the ethnically diverse society of post-conflict Sri Lanka. The survey sample included 5136 participants (86% response rate) followed up 12 months after a baseline nationally representative survey undertaken in Sri Lanka in 2014. Exposure to conflict-related traumatic experiences (TEs) generating a trauma count (TC), and symptoms of PTSD were assessed using a modified version of the HTQ adapted to the local context. The final analytic sample included 4260 participants after excluding records with missing data on key variables. We conducted Multigroup Confirmatory Factor Analysis (MG-CFA) to test the four-factor (DSM-5 consistent) and three-factor (DSM-IV-TR) models of PTSD, then assessing measurement invariance of the four factor model by gender and ethnic groups. The three-factor and four-factor DSM-5 model each produced a good fit across the sample as a whole. In addition, there was configural, metric, and scalar invariance for the four-factor model both by gender and ethnicity. The trauma count was directly associated with each of the symptom domains of the four factor model. Our findings provide support for the capacity of the modified HTQ to measure the DSM5 construct of PTSD across gender and key ethnic groupings in Sri Lanka. Confirmation of our findings in other cultures will be important. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A statistical simulation model for field testing of non-target organisms in environmental risk assessment of genetically modified plants.

    PubMed

    Goedhart, Paul W; van der Voet, Hilko; Baldacchino, Ferdinando; Arpaia, Salvatore

    2014-04-01

    Genetic modification of plants may result in unintended effects causing potentially adverse effects on the environment. A comparative safety assessment is therefore required by authorities, such as the European Food Safety Authority, in which the genetically modified plant is compared with its conventional counterpart. Part of the environmental risk assessment is a comparative field experiment in which the effect on non-target organisms is compared. Statistical analysis of such trials come in two flavors: difference testing and equivalence testing. It is important to know the statistical properties of these, for example, the power to detect environmental change of a given magnitude, before the start of an experiment. Such prospective power analysis can best be studied by means of a statistical simulation model. This paper describes a general framework for simulating data typically encountered in environmental risk assessment of genetically modified plants. The simulation model, available as Supplementary Material, can be used to generate count data having different statistical distributions possibly with excess-zeros. In addition the model employs completely randomized or randomized block experiments, can be used to simulate single or multiple trials across environments, enables genotype by environment interaction by adding random variety effects, and finally includes repeated measures in time following a constant, linear or quadratic pattern in time possibly with some form of autocorrelation. The model also allows to add a set of reference varieties to the GM plants and its comparator to assess the natural variation which can then be used to set limits of concern for equivalence testing. The different count distributions are described in some detail and some examples of how to use the simulation model to study various aspects, including a prospective power analysis, are provided.

  2. A statistical simulation model for field testing of non-target organisms in environmental risk assessment of genetically modified plants

    PubMed Central

    Goedhart, Paul W; van der Voet, Hilko; Baldacchino, Ferdinando; Arpaia, Salvatore

    2014-01-01

    Genetic modification of plants may result in unintended effects causing potentially adverse effects on the environment. A comparative safety assessment is therefore required by authorities, such as the European Food Safety Authority, in which the genetically modified plant is compared with its conventional counterpart. Part of the environmental risk assessment is a comparative field experiment in which the effect on non-target organisms is compared. Statistical analysis of such trials come in two flavors: difference testing and equivalence testing. It is important to know the statistical properties of these, for example, the power to detect environmental change of a given magnitude, before the start of an experiment. Such prospective power analysis can best be studied by means of a statistical simulation model. This paper describes a general framework for simulating data typically encountered in environmental risk assessment of genetically modified plants. The simulation model, available as Supplementary Material, can be used to generate count data having different statistical distributions possibly with excess-zeros. In addition the model employs completely randomized or randomized block experiments, can be used to simulate single or multiple trials across environments, enables genotype by environment interaction by adding random variety effects, and finally includes repeated measures in time following a constant, linear or quadratic pattern in time possibly with some form of autocorrelation. The model also allows to add a set of reference varieties to the GM plants and its comparator to assess the natural variation which can then be used to set limits of concern for equivalence testing. The different count distributions are described in some detail and some examples of how to use the simulation model to study various aspects, including a prospective power analysis, are provided. PMID:24834325

  3. Note: Fully integrated time-to-amplitude converter in Si-Ge technology.

    PubMed

    Crotti, M; Rech, I; Ghioni, M

    2010-10-01

    Over the past years an always growing interest has arisen about the measurement technique of time-correlated single photon counting TCSPC), since it allows the analysis of extremely fast and weak light waveforms with a picoseconds resolution. Consequently, many applications exploiting TCSPC have been developed in several fields such as medicine and chemistry. Moreover, the development of multianode PMT and of single photon avalanche diode arrays led to the realization of acquisition systems with several parallel channels to employ the TCSPC technique in even more applications. Since TCSPC basically consists of the measurement of the arrival time of a photon, the most important part of an acquisition chain is the time measurement block, which must have high resolution and low differential nonlinearity, and in order to realize multidimensional systems, it has to be integrated to reduce both cost and area. In this paper we present a fully integrated time-to-amplitude converter, built in 0.35 μm Si-Ge technology, characterized by a good time resolution (60 ps), low differential nonlinearity (better than 3% peak to peak), high counting rate (16 MHz), low and constant power dissipation (40 mW), and low area occupation (1.38×1.28 mm(2)).

  4. 3-Axis Fully-Integrated Capacitive Tactile Sensor with Flip-Bonded CMOS on LTCC Interposer.

    PubMed

    Asano, Sho; Muroyama, Masanori; Nakayama, Takahiro; Hata, Yoshiyuki; Nonomura, Yutaka; Tanaka, Shuji

    2017-10-25

    This paper reports a 3-axis fully integrated differential capacitive tactile sensor surface-mountable on a bus line. The sensor integrates a flip-bonded complementary metal-oxide semiconductor (CMOS) with capacitive sensing circuits on a low temperature cofired ceramic (LTCC) interposer with Au through vias by Au-Au thermo-compression bonding. The CMOS circuit and bonding pads on the sensor backside were electrically connected through Au bumps and the LTCC interposer, and the differential capacitive gap was formed by an Au sealing frame. A diaphragm for sensing 3-axis force was formed in the CMOS substrate. The dimensions of the completed sensor are 2.5 mm in width, 2.5 mm in length, and 0.66 mm in thickness. The fabricated sensor output coded 3-axis capacitive sensing data according to applied 3-axis force by three-dimensional (3D)-printed pins. The measured sensitivity was as high as over 34 Count/mN for normal force and 14 to 15 Count/mN for shear force with small noise, which corresponds to less than 1 mN. The hysteresis and the average cross-sensitivity were also found to be less than 2% full scale and 11%, respectively.

  5. 3-Axis Fully-Integrated Capacitive Tactile Sensor with Flip-Bonded CMOS on LTCC Interposer †

    PubMed Central

    Asano, Sho; Nakayama, Takahiro; Hata, Yoshiyuki; Tanaka, Shuji

    2017-01-01

    This paper reports a 3-axis fully integrated differential capacitive tactile sensor surface-mountable on a bus line. The sensor integrates a flip-bonded complementary metal-oxide semiconductor (CMOS) with capacitive sensing circuits on a low temperature cofired ceramic (LTCC) interposer with Au through vias by Au-Au thermo-compression bonding. The CMOS circuit and bonding pads on the sensor backside were electrically connected through Au bumps and the LTCC interposer, and the differential capacitive gap was formed by an Au sealing frame. A diaphragm for sensing 3-axis force was formed in the CMOS substrate. The dimensions of the completed sensor are 2.5 mm in width, 2.5 mm in length, and 0.66 mm in thickness. The fabricated sensor output coded 3-axis capacitive sensing data according to applied 3-axis force by three-dimensional (3D)-printed pins. The measured sensitivity was as high as over 34 Count/mN for normal force and 14 to 15 Count/mN for shear force with small noise, which corresponds to less than 1 mN. The hysteresis and the average cross-sensitivity were also found to be less than 2% full scale and 11%, respectively. PMID:29068429

  6. Automated Mobile System for Accurate Outdoor Tree Crop Enumeration Using an Uncalibrated Camera.

    PubMed

    Nguyen, Thuy Tuong; Slaughter, David C; Hanson, Bradley D; Barber, Andrew; Freitas, Amy; Robles, Daniel; Whelan, Erin

    2015-07-28

    This paper demonstrates an automated computer vision system for outdoor tree crop enumeration in a seedling nursery. The complete system incorporates both hardware components (including an embedded microcontroller, an odometry encoder, and an uncalibrated digital color camera) and software algorithms (including microcontroller algorithms and the proposed algorithm for tree crop enumeration) required to obtain robust performance in a natural outdoor environment. The enumeration system uses a three-step image analysis process based upon: (1) an orthographic plant projection method integrating a perspective transform with automatic parameter estimation; (2) a plant counting method based on projection histograms; and (3) a double-counting avoidance method based on a homography transform. Experimental results demonstrate the ability to count large numbers of plants automatically with no human effort. Results show that, for tree seedlings having a height up to 40 cm and a within-row tree spacing of approximately 10 cm, the algorithms successfully estimated the number of plants with an average accuracy of 95.2% for trees within a single image and 98% for counting of the whole plant population in a large sequence of images.

  7. Automated Mobile System for Accurate Outdoor Tree Crop Enumeration Using an Uncalibrated Camera

    PubMed Central

    Nguyen, Thuy Tuong; Slaughter, David C.; Hanson, Bradley D.; Barber, Andrew; Freitas, Amy; Robles, Daniel; Whelan, Erin

    2015-01-01

    This paper demonstrates an automated computer vision system for outdoor tree crop enumeration in a seedling nursery. The complete system incorporates both hardware components (including an embedded microcontroller, an odometry encoder, and an uncalibrated digital color camera) and software algorithms (including microcontroller algorithms and the proposed algorithm for tree crop enumeration) required to obtain robust performance in a natural outdoor environment. The enumeration system uses a three-step image analysis process based upon: (1) an orthographic plant projection method integrating a perspective transform with automatic parameter estimation; (2) a plant counting method based on projection histograms; and (3) a double-counting avoidance method based on a homography transform. Experimental results demonstrate the ability to count large numbers of plants automatically with no human effort. Results show that, for tree seedlings having a height up to 40 cm and a within-row tree spacing of approximately 10 cm, the algorithms successfully estimated the number of plants with an average accuracy of 95.2% for trees within a single image and 98% for counting of the whole plant population in a large sequence of images. PMID:26225982

  8. Semantic similarity measure in biomedical domain leverage web search engine.

    PubMed

    Chen, Chi-Huang; Hsieh, Sheau-Ling; Weng, Yung-Ching; Chang, Wen-Yung; Lai, Feipei

    2010-01-01

    Semantic similarity measure plays an essential role in Information Retrieval and Natural Language Processing. In this paper we propose a page-count-based semantic similarity measure and apply it in biomedical domains. Previous researches in semantic web related applications have deployed various semantic similarity measures. Despite the usefulness of the measurements in those applications, measuring semantic similarity between two terms remains a challenge task. The proposed method exploits page counts returned by the Web Search Engine. We define various similarity scores for two given terms P and Q, using the page counts for querying P, Q and P AND Q. Moreover, we propose a novel approach to compute semantic similarity using lexico-syntactic patterns with page counts. These different similarity scores are integrated adapting support vector machines, to leverage the robustness of semantic similarity measures. Experimental results on two datasets achieve correlation coefficients of 0.798 on the dataset provided by A. Hliaoutakis, 0.705 on the dataset provide by T. Pedersen with physician scores and 0.496 on the dataset provided by T. Pedersen et al. with expert scores.

  9. A comparison of altimeter and gravimetric geoids in the Tonga Trench and Indian Ocean areas

    NASA Technical Reports Server (NTRS)

    Rapp, R. H.

    1980-01-01

    Geoids computed from GEOS-3 altimeter data are compared with gravimetric geoids computed by various techniques for 30 x 30 deg areas in the Tonga Trench and the Indian Ocean. The gravimetric geoids were calculated using the standard Stokes integration with the Molodenskii truncation procedure, the modified Stokes integration suggested by Ostach (1970) and Meissl (1971) with modified Molodenskii truncation functions, and three sets of potential coefficients including one complete to degree 180. It is found that the modified Stokes procedure with a cap size of 10 deg provides better results when used with a combined altimeter terrestrial anomaly field data set. Excellent agreement at the plus or minus 1 m level is obtained between the altimeter and gravimetric geoid using the combined data set, with the modified Stokes procedure having a greater accuracy. Coefficients derived from the 180 x 180 solution are found to be of an accuracy comparable to that of the modified Stokes method, however to require six times less computational effort.

  10. Monte Carlo simulation of inverse geometry x-ray fluoroscopy using a modified MC-GPU framework

    PubMed Central

    Dunkerley, David A. P.; Tomkowiak, Michael T.; Slagowski, Jordan M.; McCabe, Bradley P.; Funk, Tobias; Speidel, Michael A.

    2015-01-01

    Scanning-Beam Digital X-ray (SBDX) is a technology for low-dose fluoroscopy that employs inverse geometry x-ray beam scanning. To assist with rapid modeling of inverse geometry x-ray systems, we have developed a Monte Carlo (MC) simulation tool based on the MC-GPU framework. MC-GPU version 1.3 was modified to implement a 2D array of focal spot positions on a plane, with individually adjustable x-ray outputs, each producing a narrow x-ray beam directed toward a stationary photon-counting detector array. Geometric accuracy and blurring behavior in tomosynthesis reconstructions were evaluated from simulated images of a 3D arrangement of spheres. The artifact spread function from simulation agreed with experiment to within 1.6% (rRMSD). Detected x-ray scatter fraction was simulated for two SBDX detector geometries and compared to experiments. For the current SBDX prototype (10.6 cm wide by 5.3 cm tall detector), x-ray scatter fraction measured 2.8–6.4% (18.6–31.5 cm acrylic, 100 kV), versus 2.1–4.5% in MC simulation. Experimental trends in scatter versus detector size and phantom thickness were observed in simulation. For dose evaluation, an anthropomorphic phantom was imaged using regular and regional adaptive exposure (RAE) scanning. The reduction in kerma-area-product resulting from RAE scanning was 45% in radiochromic film measurements, versus 46% in simulation. The integral kerma calculated from TLD measurement points within the phantom was 57% lower when using RAE, versus 61% lower in simulation. This MC tool may be used to estimate tomographic blur, detected scatter, and dose distributions when developing inverse geometry x-ray systems. PMID:26113765

  11. Quantitative 3-D Corneal Imaging In Vivo Using a Modified HRT- RCM Confocal Microscope

    PubMed Central

    Petroll, W. Matthew.; Weaver, Matthew; Vaidya, Saurabh; McCulley, James P.; Cavanagh, H. Dwight

    2012-01-01

    Purpose The purpose of this study was to develop and test hardware and software modifications to allow quantitative full-thickness corneal imaging using the HRT Rostock Corneal Module. Methods A PC-controlled motor drive with positional feedback was integrated into the system to allow automated focusing through the entire cornea. The left eyes of ten New Zealand White rabbits were scanned from endothelium to epithelium. Image sequences were read into a custom-developed program for depth calculation and measurement of sub-layer thicknesses. 3-D visualizations were also generated using Imaris. In six rabbits, stack images were registered, and depth-dependent counts of keratocyte nuclei were made using Metamorph. Results The mean epithelial and corneal thicknesses measured in the rabbit were 47 ± 5 μm and 373 ± 25 μm, respectively (N = 10 corneas); coefficients of variation for repeated scans were 8.2% and 2.1%. Corneal thickness measured using ultrasonic pachymetry was 374 ± 17 μm. The mean overall keratocyte density measured in the rabbit was 43,246 ± 5,603 cells/mm3 in vivo (N = 6 corneas). There was a gradual decrease in keratocyte density from the anterior to posterior cornea (R = 0.99), consistent with previous data generated in vitro. Conclusions This modified system allows high resolution 3-D image stacks to be collected from the full thickness rabbit cornea in vivo. These datasets can be used for interactive visualization of corneal cell layers, measurement of sub-layer thickness, and depth-dependent keratocyte density measurements. Overall, the modifications significantly expand the potential quantitative research applications of the HRT-RCM microscope. PMID:23051907

  12. Synergistic effect of spice extracts and modified atmospheric packaging towards non-thermal preservation of chicken meat under refrigerated storage.

    PubMed

    Sivarajan, M; Lalithapriya, U; Mariajenita, Peter; Vajiha, B Aafrin; Harini, K; Madhushalini, D; Sukumar, M

    2017-08-01

    This study investigates the integrated approach of spice extracts and modified atmospheric packaging (MAP) chicken meat preservation. Specifically, extracts from clove (CL), cinnamon (CI) individually and in combination (3% w/w) along with MAP (30% CO2/70% N2 and 10% O2/30% CO2/60% N2) were used to increase the shelf life of fresh chicken meat stored at 4°C. The parameters evaluated as shelf life indications are microbiological (total viable count, Pseudomonas spp., lactic acid bacteria (LAB), and Enterobacteriaceae), physicochemical (pH, Lipid oxidation, color changes) and Sensory attributes. Microbial population were reduced by 2.5 to 5 log cfu/g, with the greater impact being accomplished by the blend of clove and cinnamon extract with 30% CO2/70% N2 MAP. Thiobarbituric values for all treated and MAP packed samples remained lower than 1 mg malondialdehyde (MDA)/kg all through the 24 day storage period. pH values varied from 5.5 for fresh sample on day 0 to 7.11 (day 25) on combined extract treated and MAP packaged samples. The estimations of the color parameters L*, a*, and b* were well maintained in oxygen deficient MAP. Finally, sensory investigation demonstrated that combined clove and cinnamon extract of 3% conferred acceptable sensory attributes to the samples on day 24 of storage. These results indicate the extended shelf life of chicken meat from 4 days to 24 days for samples when coated with 3% of combined clove and cinnamon extract and packaged under MAP without oxygen. These pooled extracts along with MAP displayed expanded the usability and the organoleptic qualities of chicken meat. © 2017 Poultry Science Association Inc.

  13. Monte Carlo simulation of inverse geometry x-ray fluoroscopy using a modified MC-GPU framework.

    PubMed

    Dunkerley, David A P; Tomkowiak, Michael T; Slagowski, Jordan M; McCabe, Bradley P; Funk, Tobias; Speidel, Michael A

    2015-02-21

    Scanning-Beam Digital X-ray (SBDX) is a technology for low-dose fluoroscopy that employs inverse geometry x-ray beam scanning. To assist with rapid modeling of inverse geometry x-ray systems, we have developed a Monte Carlo (MC) simulation tool based on the MC-GPU framework. MC-GPU version 1.3 was modified to implement a 2D array of focal spot positions on a plane, with individually adjustable x-ray outputs, each producing a narrow x-ray beam directed toward a stationary photon-counting detector array. Geometric accuracy and blurring behavior in tomosynthesis reconstructions were evaluated from simulated images of a 3D arrangement of spheres. The artifact spread function from simulation agreed with experiment to within 1.6% (rRMSD). Detected x-ray scatter fraction was simulated for two SBDX detector geometries and compared to experiments. For the current SBDX prototype (10.6 cm wide by 5.3 cm tall detector), x-ray scatter fraction measured 2.8-6.4% (18.6-31.5 cm acrylic, 100 kV), versus 2.1-4.5% in MC simulation. Experimental trends in scatter versus detector size and phantom thickness were observed in simulation. For dose evaluation, an anthropomorphic phantom was imaged using regular and regional adaptive exposure (RAE) scanning. The reduction in kerma-area-product resulting from RAE scanning was 45% in radiochromic film measurements, versus 46% in simulation. The integral kerma calculated from TLD measurement points within the phantom was 57% lower when using RAE, versus 61% lower in simulation. This MC tool may be used to estimate tomographic blur, detected scatter, and dose distributions when developing inverse geometry x-ray systems.

  14. Integration of bus stop counts data with census data for improving bus service.

    DOT National Transportation Integrated Search

    2016-04-01

    This research project produced an open source transit market data visualization and analysis tool suite, : The Bus Transit Market Analyst (BTMA), which contains user-friendly GIS mapping and data : analytics tools, and state-of-the-art transit demand...

  15. Efficiency of synaptic transmission of single-photon events from rod photoreceptor to rod bipolar dendrite.

    PubMed

    Schein, Stan; Ahmad, Kareem M

    2006-11-01

    A rod transmits absorption of a single photon by what appears to be a small reduction in the small number of quanta of neurotransmitter (Q(count)) that it releases within the integration period ( approximately 0.1 s) of a rod bipolar dendrite. Due to the quantal and stochastic nature of release, discrete distributions of Q(count) for darkness versus one isomerization of rhodopsin (R*) overlap. We suggested that release must be regular to narrow these distributions, reduce overlap, reduce the rate of false positives, and increase transmission efficiency (the fraction of R* events that are identified as light). Unsurprisingly, higher quantal release rates (Q(rates)) yield higher efficiencies. Focusing here on the effect of small changes in Q(rate), we find that a slightly higher Q(rate) yields greatly reduced efficiency, due to a necessarily fixed quantal-count threshold. To stabilize efficiency in the face of drift in Q(rate), the dendrite needs to regulate the biochemical realization of its quantal-count threshold with respect to its Q(count). These considerations reveal the mathematical role of calcium-based negative feedback and suggest a helpful role for spontaneous R*. In addition, to stabilize efficiency in the face of drift in degree of regularity, efficiency should be approximately 50%, similar to measurements.

  16. A new approach for measuring the work and quality of histopathology reporting.

    PubMed

    Sharma, Vijay; Davey, Jonathan G N; Humphreys, Catherine; Johnston, Peter W

    2013-07-01

    Cancer datasets drive report quality, but require more work to inform compliant reports. The aim of this study was to correlate the number of words with measures of quality, to examine the impact of the drive for improved quality on the workload of histopathology reporting over time. We examined the first 10 reports of colon, breast, renal, lung and ovarian carcinoma, melanoma resection, nodal lymphoma appendicitis and seborrhoeic keratosis (SK) issued in 1991, 2001 and 2011. Correlations were analysed using Pearson's partial correlation coefficients. Word count increased significantly over time for most specimen types examined. Word count almost always correlated with units of information, indicating that the word count was a good measure of the amount of information contained within the reports; this correlation was preserved following correction for the effect of time. A good correlation with compliance with cancer datasets was also observed, but was weakened or lost following correction for the increase in word count and units of information that occurred between time points. These data indicate that word count could potentially be used as a measure of information content if its integrity and usefulness are continuously validated. Further prospective studies are required to assess and validate this approach. © 2013 John Wiley & Sons Ltd.

  17. Biocompatibility and tissue integration of a novel shape memory surgical mesh for ventral hernia: In vivo animal studies

    PubMed Central

    Zimkowski, Michael M.; Rentschler, Mark E.; Schoen, Jonathan A.; Mandava, Nageswara; Shandas, Robin

    2014-01-01

    Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs. The placement of surgical mesh in a ventral hernia repair procedure can be challenging, and may even complicate the procedure. Others have attempted to provide commercial solutions to the problems of mesh placement, but these have not been well accepted by the clinical community. In this article, two versions of shape memory polymer (SMP)-modified surgical mesh, and unmodified surgical mesh, were compared by performing laparoscopic manipulation in an acute porcine model. Also, SMP-integrated polyester surgical meshes were implanted in four rats for 30–33 days to evaluate chronic biocompatibility and capacity for tissue integration. Porcine results show that the modified mesh provides a controlled, temperature-activated, automated deployment when compared to an unmodified mesh. In rats, results indicate that implanted SMP-modified meshes exhibit exceptional biocompatibility and excellent integration with surrounding tissue with no noticeable differences from the unmodified counterpart. This article provides further evidence that an SMP-modified surgical mesh promises reduction in surgical placement time and that such a mesh is not substantially different from unmodified meshes in chronic biocompatibility. PMID:24327401

  18. Body sway adaptation to addition but not withdrawal of stabilizing visual information is delayed by a concurrent cognitive task.

    PubMed

    Honeine, Jean-Louis; Crisafulli, Oscar; Schieppati, Marco

    2017-02-01

    The aim of this study was to test the effects of a concurrent cognitive task on the promptness of the sensorimotor integration and reweighting processes following addition and withdrawal of vision. Fourteen subjects stood in tandem while vision was passively added and removed. Subjects performed a cognitive task, consisting of counting backward in steps of three, or were "mentally idle." We estimated the time intervals following addition and withdrawal of vision at which body sway began to change. We also estimated the time constant of the exponential change in body oscillation until the new level of sway was reached, consistent with the current visual state. Under the mentally idle condition, mean latency was 0.67 and 0.46 s and the mean time constant was 1.27 and 0.59 s for vision addition and withdrawal, respectively. Following addition of vision, counting backward delayed the latency by about 300 ms, without affecting the time constant. Following withdrawal, counting backward had no significant effect on either latency or time constant. The extension by counting backward of the time interval to stabilization onset on addition of vision suggests a competition for allocation of cortical resources. Conversely, the absence of cognitive task effect on the rapid onset of destabilization on vision withdrawal, and on the relevant reweighting time course, advocates the intervention of a subcortical process. Diverting attention from a challenging standing task discloses a cortical supervision on the process of sensorimotor integration of new balance-stabilizing information. A subcortical process would instead organize the response to removal of the stabilizing sensory input. NEW & NOTEWORTHY This study is the first to test the effect of an arithmetic task on the time course of balance readjustment following visual withdrawal or addition. Performing such a cognitive task increases the time delay following addition of vision but has no effect on withdrawal dynamics. This suggests that sensorimotor integration following addition of a stabilizing signal is performed at a cortical level, whereas the response to its withdrawal is "automatic" and accomplished at a subcortical level. Copyright © 2017 the American Physiological Society.

  19. Accuracy of neutron self-activation method with iodine-containing scintillators for quantifying 128I generation using decay-fitting technique

    NASA Astrophysics Data System (ADS)

    Nohtomi, Akihiro; Wakabayashi, Genichiro

    2015-11-01

    We evaluated the accuracy of a self-activation method with iodine-containing scintillators in quantifying 128I generation in an activation detector; the self-activation method was recently proposed for photo-neutron on-line measurements around X-ray radiotherapy machines. Here, we consider the accuracy of determining the initial count rate R0, observed just after termination of neutron irradiation of the activation detector. The value R0 is directly related to the amount of activity generated by incident neutrons; the detection efficiency of radiation emitted from the activity should be taken into account for such an evaluation. Decay curves of 128I activity were numerically simulated by a computer program for various conditions including different initial count rates (R0) and background rates (RB), as well as counting statistical fluctuations. The data points sampled at minute intervals and integrated over the same period were fit by a non-linear least-squares fitting routine to obtain the value R0 as a fitting parameter with an associated uncertainty. The corresponding background rate RB was simultaneously calculated in the same fitting routine. Identical data sets were also evaluated by a well-known integration algorithm used for conventional activation methods and the results were compared with those of the proposed fitting method. When we fixed RB = 500 cpm, the relative uncertainty σR0 /R0 ≤ 0.02 was achieved for R0/RB ≥ 20 with 20 data points from 1 min to 20 min following the termination of neutron irradiation used in the fitting; σR0 /R0 ≤ 0.01 was achieved for R0/RB ≥ 50 with the same data points. Reasonable relative uncertainties to evaluate initial count rates were reached by the decay-fitting method using practically realistic sampling numbers. These results clarified the theoretical limits of the fitting method. The integration method was found to be potentially vulnerable to short-term variations in background levels, especially instantaneous contaminations by spike-like noise. The fitting method easily detects and removes such spike-like noise.

  20. Implementation and Operational Research: Integration of PMTCT and Antenatal Services Improves Combination Antiretroviral Therapy Uptake for HIV-Positive Pregnant Women in Southern Zambia: A Prototype for Option B+?

    PubMed

    Herlihy, Julie M; Hamomba, Leoda; Bonawitz, Rachael; Goggin, Caitlin E; Sambambi, Kennedy; Mwale, Jonas; Musonda, Victor; Musokatwane, Kebby; Hopkins, Kathryn L; Semrau, Katherine; Hammond, Emily E; Duncan, Julie; Knapp, Anna B; Thea, Donald M

    2015-12-01

    Early initiation of combination antiretroviral therapy (cART) for HIV-positive pregnant women can decrease vertical transmission to less than 5%. Programmatic barriers to early cART include decentralized care, disease-stage assessment delays, and loss to follow-up. Our intervention had 3 components: integrated HIV and antenatal services in 1 location with 1 provider, laboratory courier to expedite CD4 counts, and community-based follow-up of women-infant pairs to improve prevention of mother-to-child transmission attendance. Preintervention HIV-positive pregnant women were referred to HIV clinics for disease-stage assessment and cART initiation for advanced disease (CD4 count <350 cells/μL or WHO stage >2). We used a quasi-experimental design with preintervention/postintervention evaluations at 6 government antenatal clinics (ANCs) in Southern Province, Zambia. Retrospective clinical data were collected from clinic registers during a 7-month baseline period. Postintervention data were collected from all antiretroviral therapy-naive, HIV-positive pregnant women and their infants presenting to ANC from December 2011 to June 2013. Data from 510 baseline women-infant pairs were analyzed and 624 pregnant women were enrolled during the intervention period. The proportion of HIV-positive pregnant women receiving CD4 counts increased from 50.6% to 77.2% [relative risk (RR) = 1.81; 95% confidence interval (CI): 1.57 to 2.08; P < 0.01]. The proportion of cART-eligible pregnant women initiated on cART increased from 27.5% to 71.5% (RR = 2.25; 95% CI: 1.78 to 2.83; P < 0.01). The proportion of eligible HIV-exposed infants with documented 6-week HIV PCR test increased from 41.9% to 55.8% (RR = 1.33; 95% CI: 1.18 to 1.51; P < 0.01). Integration of HIV care into ANC and community-based support improved uptake of CD4 counts, proportion of cART-eligible women initiated on cART, and infants tested.

  1. [Application of negative binomial regression and modified Poisson regression in the research of risk factors for injury frequency].

    PubMed

    Cao, Qingqing; Wu, Zhenqiang; Sun, Ying; Wang, Tiezhu; Han, Tengwei; Gu, Chaomei; Sun, Yehuan

    2011-11-01

    To Eexplore the application of negative binomial regression and modified Poisson regression analysis in analyzing the influential factors for injury frequency and the risk factors leading to the increase of injury frequency. 2917 primary and secondary school students were selected from Hefei by cluster random sampling method and surveyed by questionnaire. The data on the count event-based injuries used to fitted modified Poisson regression and negative binomial regression model. The risk factors incurring the increase of unintentional injury frequency for juvenile students was explored, so as to probe the efficiency of these two models in studying the influential factors for injury frequency. The Poisson model existed over-dispersion (P < 0.0001) based on testing by the Lagrangemultiplier. Therefore, the over-dispersion dispersed data using a modified Poisson regression and negative binomial regression model, was fitted better. respectively. Both showed that male gender, younger age, father working outside of the hometown, the level of the guardian being above junior high school and smoking might be the results of higher injury frequencies. On a tendency of clustered frequency data on injury event, both the modified Poisson regression analysis and negative binomial regression analysis can be used. However, based on our data, the modified Poisson regression fitted better and this model could give a more accurate interpretation of relevant factors affecting the frequency of injury.

  2. Comparison of Three Bed Bug Management Strategies in a Low-Income Apartment Building

    PubMed Central

    Wang, Changlu; Saltzmann, Kurt; Bennett, Gary; Gibb, Timothy

    2012-01-01

    Bed bug (Cimex lectularius L.) infestations are currently controlled by a variety of non-chemical and chemical methods. There have been few studies on the comparative effectiveness of these control techniques. We evaluated three bed bug management strategies in an apartment building: (1) non-chemical methods only (n = 9); (2) insecticides only (n = 6); and (3) integrated pest management including both non-chemical methods and insecticides (n = 9). The apartments were one-bedroom units occupied by seniors or people with disabilities. Bed bug numbers in each apartment were determined by visual inspection and/or installing intercepting devices under bed and sofa legs. The median (min, max) bed bug counts in the non-chemical methods only, insecticides only, and integrated pest management (IPM) treatment were: 4 (1, 57), 19 (1, 250), and 14 (1, 219), respectively prior to the treatments. The apartments were retreated if found necessary during biweekly to monthly inspections. After 10 weeks, bed bugs were found to be eliminated from 67, 33, and 44% of the apartments in the three treatment groups, respectively. The final (after 10 weeks) median (min, max) bed bug counts in the non-chemical methods only, insecticides only, and IPM treatment were: 0 (0, 134), 11.5 (0, 58), and 1 (0, 38), respectively. There were no significant differences in the speed of bed bug count reduction or the final bed bug counts. Lack of resident cooperation partially contributed to the failure in eliminating bed bugs from some of the apartments. Results of this study suggest that non-chemical methods can effectively eliminate bed bugs in lightly infested apartments. PMID:26466533

  3. 2D dark-count-rate modeling of PureB single-photon avalanche diodes in a TCAD environment

    NASA Astrophysics Data System (ADS)

    Knežević, Tihomir; Nanver, Lis K.; Suligoj, Tomislav

    2018-02-01

    PureB silicon photodiodes have nm-shallow p+n junctions with which photons/electrons with penetration-depths of a few nanometer can be detected. PureB Single-Photon Avalanche Diodes (SPADs) were fabricated and analysed by 2D numerical modeling as an extension to TCAD software. The very shallow p+ -anode has high perimeter curvature that enhances the electric field. In SPADs, noise is quantified by the dark count rate (DCR) that is a measure for the number of false counts triggered by unwanted processes in the non-illuminated device. Just like for desired events, the probability a dark count increases with increasing electric field and the perimeter conditions are critical. In this work, the DCR was studied by two 2D methods of analysis: the "quasi-2D" (Q-2D) method where vertical 1D cross-sections were assumed for calculating the electron/hole avalanche-probabilities, and the "ionization-integral 2D" (II-2D) method where crosssections were placed where the maximum ionization-integrals were calculated. The Q-2D method gave satisfactory results in structures where the peripheral regions had a small contribution to the DCR, such as in devices with conventional deepjunction guard rings (GRs). Otherwise, the II-2D method proved to be much more precise. The results show that the DCR simulation methods are useful for optimizing the compromise between fill-factor and p-/n-doping profile design in SPAD devices. For the experimentally investigated PureB SPADs, excellent agreement of the measured and simulated DCR was achieved. This shows that although an implicit GR is attractively compact, the very shallow pn-junction gives a risk of having such a low breakdown voltage at the perimeter that the DCR of the device may be negatively impacted.

  4. Investigating the effects of dietary folic acid on sperm count, DNA damage and mutation in Balb/c mice.

    PubMed

    Swayne, Breanne G; Kawata, Alice; Behan, Nathalie A; Williams, Andrew; Wade, Mike G; Macfarlane, Amanda J; Yauk, Carole L

    2012-09-01

    To date, fewer than 50 mutagens have been studied for their ability to cause heritable mutations. The majority of those studied are classical mutagens like radiation and anti-cancer drugs. Very little is known about the dietary variables influencing germline mutation rates. Folate is essential for DNA synthesis and methylation and can impact chromatin structure. We therefore determined the effects of folic acid-deficient (0mg/kg), control (2mg/kg) and supplemented (6mg/kg) diets in early development and during lactation or post-weaning on mutation rates and chromatin quality in sperm of adult male Balb/c mice. The sperm chromatin structure assay and mutation frequencies at expanded simple tandem repeats (ESTRs) were used to evaluate germline DNA integrity. Treatment of a subset of mice fed the control diet with the mutagen ethylnitrosourea (ENU) at 8 weeks of age was included as a positive control. ENU treated mice exhibited decreased cauda sperm counts, increased DNA fragmentation and increased ESTR mutation frequencies relative to non-ENU treated mice fed the control diet. Male mice weaned to the folic acid deficient diet had decreased cauda sperm numbers, increased DNA fragmentation index, and increased ESTR mutation frequency. Folic acid deficiency in early development did not lead to changes in sperm counts or chromatin integrity in adult mice. Folic acid supplementation in early development or post-weaning did not affect germ cell measures. Therefore, adequate folic acid intake in adulthood is important for preventing chromatin damage and mutation in the male germline. Folic acid supplementation at the level achieved in this study does not improve nor is it detrimental to male germline chromatin integrity. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  5. Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

    DOE PAGES

    Friend, M.; Parno, D.; Benmokhtar, F.; ...

    2012-06-01

    The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

  6. Towards a Graphene-Based Low Intensity Photon Counting Photodetector

    PubMed Central

    Williams, Jamie O. D.; Alexander-Webber, Jack A.; Lapington, Jon S.; Roy, Mervyn; Hutchinson, Ian B.; Sagade, Abhay A.; Martin, Marie-Blandine; Braeuninger-Weimer, Philipp; Cabrero-Vilatela, Andrea; Wang, Ruizhi; De Luca, Andrea; Udrea, Florin; Hofmann, Stephan

    2016-01-01

    Graphene is a highly promising material in the development of new photodetector technologies, in particular due its tunable optoelectronic properties, high mobilities and fast relaxation times coupled to its atomic thinness and other unique electrical, thermal and mechanical properties. Optoelectronic applications and graphene-based photodetector technology are still in their infancy, but with a range of device integration and manufacturing approaches emerging this field is progressing quickly. In this review we explore the potential of graphene in the context of existing single photon counting technologies by comparing their performance to simulations of graphene-based single photon counting and low photon intensity photodetection technologies operating in the visible, terahertz and X-ray energy regimes. We highlight the theoretical predictions and current graphene manufacturing processes for these detectors. We show initial experimental implementations and discuss the key challenges and next steps in the development of these technologies. PMID:27563903

  7. Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector

    NASA Astrophysics Data System (ADS)

    Lundqvist, Mats; Danielsson, Mats; Cederstroem, Bjoern; Chmill, Valery; Chuntonov, Alexander; Aslund, Magnus

    2003-06-01

    Sectra Microdose is the first single photon counting mammography detector. An edge-on crystalline silicon detector is connected to application specific integrated circuits that individually process each photon. The detector is scanned across the breast and the rejection of scattered radiation exceeds 97% without the use of a Bucky. Processing of each x-rays individually enables an optimization of the information transfer from the x-rays to the image in a way previously not possible. Combined with an almost absence of noise from scattered radiation and from electronics we foresee a possibility to reduce the radiation dose and/or increase the image quality. We will discuss fundamental features of the new direct photon counting technique in terms of dose efficiency and present preliminary measurements for a prototype on physical parameters such as Noise Power Spectra (NPS), MTF and DQE.

  8. Demonstration of the feasibility of large-port-count optical switching using a hybrid Mach-Zehnder interferometer-semiconductor optical amplifier switch module in a recirculating loop.

    PubMed

    Cheng, Q; Wonfor, A; Wei, J L; Penty, R V; White, I H

    2014-09-15

    For what we believe is the first time, the feasibility of large-port-count nanosecond-reconfiguration-time optical switches is demonstrated using a hybrid approach, where Mach-Zehnder interferometric (MZI) switches provide low-loss, high-speed routing with short semiconductor optical amplifiers (SOAs) being integrated to enhance extinction. By repeatedly passing signals through a monolithic hybrid dilated 2×2 switch module in a recirculating loop, the potential performance of high-port-count switches using the hybrid approach is demonstrated. Experimentally, a single pass switch penalty of only 0.1 dB is demonstrated for the 2×2 module, while even after seven passes through the switch, equivalent to a 128×128 router, a penalty of only 2.4 dB is recorded at a data rate of 10 Gb/s.

  9. Geometric Lagrangian approach to the physical degree of freedom count in field theory

    NASA Astrophysics Data System (ADS)

    Díaz, Bogar; Montesinos, Merced

    2018-05-01

    To circumvent some technical difficulties faced by the geometric Lagrangian approach to the physical degree of freedom count presented in the work of Díaz, Higuita, and Montesinos [J. Math. Phys. 55, 122901 (2014)] that prevent its direct implementation to field theory, in this paper, we slightly modify the geometric Lagrangian approach in such a way that its resulting version works perfectly for field theory (and for particle systems, of course). As in previous work, the current approach also allows us to directly get the Lagrangian constraints, a new Lagrangian formula for the counting of the number of physical degrees of freedom, the gauge transformations, and the number of first- and second-class constraints for any action principle based on a Lagrangian depending on the fields and their first derivatives without performing any Dirac's canonical analysis. An advantage of this approach over the previous work is that it also allows us to handle the reducibility of the constraints and to get the off-shell gauge transformations. The theoretical framework is illustrated in 3-dimensional generalized general relativity (Palatini and Witten's exotic actions), Chern-Simons theory, 4-dimensional BF theory, and 4-dimensional general relativity given by Palatini's action with a cosmological constant.

  10. Bifidobacterium breve IPLA20005 affects in vitro the expression of hly and luxS genes, related to the virulence of Listeria monocytogenes Lm23.

    PubMed

    Rios-Covian, David; Nogacka, Alicja; Salazar, Nuria; Hernández-Barranco, A M; Cuesta, Isabel; Gueimonde, Miguel; de Los Reyes Gavilán, Clara G

    2018-03-01

    Mechanistic features that characterize the interaction and inhibition of the food-borne pathogen Listeria monocytogenes by members of the genus Bifidobacterium still remain unclear. In the present work, we tried to shed light on the influence that co-cultivation of L. monocytogenes with Bifidobacterium breve may exert on both microorganisms and on virulence of the pathogen. Production of acetate and lactate was measured by gas chromatography and high-performance liquid chromatography, respectively; bacterial counts were obtained by plate count; gene expression was determined by RT-qPCR; and haemolytic activity was analyzed against goat erythrocytes. We found slightly but significantly lower final counts of Listeria and Bifidobacterium (p < 0.05) and lower haemolytic efficiency in L. monocytogenes cells from cocultures than in those from monocultures. In contrast, the hly and luxS genes, which code for the cytolysin listeriolysin O and participate in biofilm formation, respectively, were overexpressed when L. monocytogenes was grown in coculture. This indicates that the presence of Bifidobacterium is able to modify the gene expression and haemolytic activity of L. monocytogenes when both microorganisms grow together.

  11. Modeling of optical quadrature microscopy for imaging mouse embryos

    NASA Astrophysics Data System (ADS)

    Warger, William C., II; DiMarzio, Charles A.

    2008-02-01

    Optical quadrature microscopy (OQM) has been shown to provide the optical path difference through a mouse embryo, and has led to a novel method to count the total number of cells further into development than current non-toxic imaging techniques used in the clinic. The cell counting method has the potential to provide an additional quantitative viability marker for blastocyst transfer during in vitro fertilization. OQM uses a 633 nm laser within a modified Mach-Zehnder interferometer configuration to measure the amplitude and phase of the signal beam that travels through the embryo. Four cameras preceded by multiple beamsplitters record the four interferograms that are used within a reconstruction algorithm to produce an image of the complex electric field amplitude. Here we present a model for the electric field through the primary optical components in the imaging configuration and the reconstruction algorithm to calculate the signal to noise ratio when imaging mouse embryos. The model includes magnitude and phase errors in the individual reference and sample paths, fixed pattern noise, and noise within the laser and detectors. This analysis provides the foundation for determining the imaging limitations of OQM and the basis to optimize the cell counting method in order to introduce additional quantitative viability markers.

  12. Determination of network origin-destination matrices using partial link traffic counts and virtual sensor information in an integrated corridor management framework.

    DOT National Transportation Integrated Search

    2014-04-01

    Trip origin-destination (O-D) demand matrices are critical components in transportation network : modeling, and provide essential information on trip distributions and corresponding spatiotemporal : traffic patterns in traffic zones in vehicular netw...

  13. Can We Really Count on Frank?

    ERIC Educational Resources Information Center

    Marston, Jennifer L.; Muir, Tracey; Livy, Sharyn

    2013-01-01

    The National Council of Teachers of Mathematics (NCTM) and the Australian National Curriculum encourage the integration of literacy and numeracy, and "Teaching Children Mathematics" ("TCM") regularly includes articles on incorporating picture books into the mathematics program. Marston has developed a new framework (2010) to assist teachers in…

  14. Investigating the Use of Integrated Instructions to Reduce the Cognitive Load Associated with Doing Practical Work in Secondary School Science

    NASA Astrophysics Data System (ADS)

    Haslam, Carolyn Yvonne; Hamilton, Richard Joseph

    2010-09-01

    This study investigated the effects of integrated illustrations on understanding instructions for practical work in science. Ninety-six secondary school students who were unfamiliar with the target content knowledge and practical equipment took part. The students were divided into two conditions: (1) modified instructions containing integrated text and illustrations, and (2) conventional instructions containing text only. Modified instructions produced significantly higher levels of performance on task, lower time to completion and perceived cognitive load and task difficulty, higher relative efficiency score, and higher post-test scores than the conventional instructions. When learners are inexperienced and the information is complex, the results suggest that physically integrating mutually referring sources of information reduces cognitive load, and therefore makes practical work instructions easier to understand.

  15. The Hard X-ray Emission from Scorpius X-1 as Seen by INTEGRAL

    NASA Technical Reports Server (NTRS)

    Sturner, S. J.; Shrader, C. R.; Weidenspointner, G.

    2008-01-01

    We present the results of our hard X-ray and gamma-ray study of the LMXB Sco X-1 utilizing INTEGRAL data as well as contemporaneous RXTE PCA data. We have concentrated on investigating the hard X-ray spectral properties of Sco X-1 including the nature of the high-energy, nonthermal component of the spectrum and its possible correlations with the location of the source on the X-ray color-color diagram. We find that Sco X-1 has two distinct spectral when the 20-40 keV count rate is greater than 140 counts/second. One state is a hard state which exhibits a significant high-energy, powerlaw tail to the lower energy thermal spectrum. The other state shows no evidence for a powerlaw tail whatsoever. We found suggestive evidence for a correlation of these hard and soft high-energy states with the position of Sco X-1 on the low-energy X-ray color-color diagram.

  16. Matter-wave diffraction approaching limits predicted by Feynman path integrals for multipath interference

    NASA Astrophysics Data System (ADS)

    Barnea, A. Ronny; Cheshnovsky, Ori; Even, Uzi

    2018-02-01

    Interference experiments have been paramount in our understanding of quantum mechanics and are frequently the basis of testing the superposition principle in the framework of quantum theory. In recent years, several studies have challenged the nature of wave-function interference from the perspective of Born's rule—namely, the manifestation of so-called high-order interference terms in a superposition generated by diffraction of the wave functions. Here we present an experimental test of multipath interference in the diffraction of metastable helium atoms, with large-number counting statistics, comparable to photon-based experiments. We use a variation of the original triple-slit experiment and accurate single-event counting techniques to provide a new experimental bound of 2.9 ×10-5 on the statistical deviation from the commonly approximated null third-order interference term in Born's rule for matter waves. Our value is on the order of the maximal contribution predicted for multipath trajectories by Feynman path integrals.

  17. Efficient high-performance ultrasound beamforming using oversampling

    NASA Astrophysics Data System (ADS)

    Freeman, Steven R.; Quick, Marshall K.; Morin, Marc A.; Anderson, R. C.; Desilets, Charles S.; Linnenbrink, Thomas E.; O'Donnell, Matthew

    1998-05-01

    High-performance and efficient beamforming circuitry is very important in large channel count clinical ultrasound systems. Current state-of-the-art digital systems using multi-bit analog to digital converters (A/Ds) have matured to provide exquisite image quality with moderate levels of integration. A simplified oversampling beamforming architecture has been proposed that may a low integration of delta-sigma A/Ds onto the same chip as digital delay and processing circuitry to form a monolithic ultrasound beamformer. Such a beamformer may enable low-power handheld scanners for high-end systems with very large channel count arrays. This paper presents an oversampling beamformer architecture that generates high-quality images using very simple; digitization, delay, and summing circuits. Additional performance may be obtained with this oversampled system for narrow bandwidth excitations by mixing the RF signal down in frequency to a range where the electronic signal to nose ratio of the delta-sigma A/D is optimized. An oversampled transmit beamformer uses the same delay circuits as receive and eliminates the need for separate transmit function generators.

  18. The Athena X-ray Integral Field Unit (X-IFU)

    NASA Technical Reports Server (NTRS)

    Barret, Didier; Trong, Thein Lam; Den Herder, Jan-Willem; Piro, Luigi; Barcons, Xavier; Huovelin, Juhani; Kelley, Richard; Mas-Hesse, J. Miquel; Mitsuda, Kazuhisa; Paltani, Stephane; hide

    2016-01-01

    The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). (2016) .

  19. Linezolid Compared with Eperezolid, Vancomycin, and Gentamicin in an In Vitro Model of Antimicrobial Lock Therapy for Staphylococcus epidermidis Central Venous Catheter-Related Biofilm Infections

    PubMed Central

    Curtin, John; Cormican, Martin; Fleming, Gerard; Keelehan, John; Colleran, Emer

    2003-01-01

    Central venous catheter (CVC)-related infection (CVC-RI) is a common complication of CVC use. The most common etiological agents of CVC-RI are gram-positive organisms, in particular, staphylococci. An in vitro model for the formation of biofilms by Staphylococcus epidermidis ATCC 35984 on polyurethane coupons in a modified Robbins device was established. Biofilm formation was confirmed by electron microscopy and was quantified by determination of viable counts. Mueller-Hinton broth was replaced with sterile physiological saline (control) or a solution of vancomycin (10 mg/ml), gentamicin (10 mg/ml), linezolid (2 mg/ml), or eperezolid (4 mg/ml). Viable counts were performed with the coupons after exposure to antimicrobials for periods of 24, 72, 168, and 240 h. The mean viable count per coupon following establishment of the biofilm was 4.6 × 108 CFU/coupon, and that after 14 days of exposure to physiological saline was 2.5 × 107 CFU/coupon. On exposure to vancomycin (10 mg/ml), the mean counts were 2.5 × 107 CFU/coupon at 24 h, 4.3 × 106 CFU/coupon at 72 h, 1.4 × 105 CFU/coupon at 168 h, and undetectable at 240 h. With gentamicin (10 mg/ml) the mean counts were 2.7 × 107 CFU/coupon at 24 h, 3.7 × 106 CFU/coupon at 72 h, 8.4 × 106 CFU/coupon at 168 h, and 6.5 × 106 CFU/coupon at 240 h. With linezolid at 2 mg/ml the mean counts were 7.1 × 105 CFU/coupon at 24 h and not detectable at 72, 168, and 240 h. With eperezolid (4 mg/ml) no viable cells were recovered after 168 h. These data suggest that linezolid (2 mg/ml) and eperezolid (4 mg/ml) achieve eradication of S. epidermidis biofilms more rapidly than vancomycin (10 mg/ml) and gentamicin (10 mg/ml). PMID:14506022

  20. Physical Activity Assessment with the ActiGraph GT3X and Doubly Labeled Water.

    PubMed

    Chomistek, Andrea K; Yuan, Changzheng; Matthews, Charles E; Troiano, Richard P; Bowles, Heather R; Rood, Jennifer; Barnett, Junaidah B; Willett, Walter C; Rimm, Eric B; Bassett, David R

    2017-09-01

    To compare the degree to which four accelerometer metrics-total activity counts per day (TAC per day), steps per day (steps per day), physical activity energy expenditure (PAEE) (kcal·kg·d), and moderate- to vigorous-intensity physical activity (MVPA) (min·d)-were correlated with PAEE measured by doubly labeled water (DLW). Additionally, accelerometer metrics based on vertical axis counts and triaxial counts were compared. This analysis included 684 women and 611 men age 43 to 83 yr. Participants wore the Actigraph GT3X on the hip for 7 d twice during the study and the average of the two measurements was used. Each participant also completed one DLW measurement, with a subset having a repeat. PAEE was estimated by subtracting resting metabolic rate and the thermic effect of food from total daily energy expenditure estimated by DLW. Partial Spearman correlations were used to estimate associations between PAEE and each accelerometer metric. Correlations between the accelerometer metrics and DLW-determined PAEE were higher for triaxial counts than vertical axis counts. After adjusting for weight, age, accelerometer wear time, and fat free mass, the correlation between TAC per day based on triaxial counts and DLW-determined PAEE was 0.44 in women and 0.41 in men. Correlations for steps per day and accelerometer-estimated PAEE with DLW-determined PAEE were similar. After adjustment for within-person variation in DLW-determined PAEE, the correlations for TAC per day increased to 0.61 and 0.49, respectively. Correlations between MVPA and DLW-determined PAEE were lower, particularly for modified bouts of ≥10 min. Accelerometer measures that represent total activity volume, including TAC per day, steps per day, and PAEE, were more highly correlated with DLW-determined PAEE than MVPA using traditional thresholds and should be considered by researchers seeking to reduce accelerometer data to a single metric.

  1. Late presentation to HIV testing is overestimated when based on the consensus definition.

    PubMed

    Sasse, A; Florence, E; Pharris, A; De Wit, S; Lacor, P; Van Beckhoven, D; Deblonde, J; Delforge, M-L; Fransen, K; Goffard, J-C; Legrand, J-C; Moutschen, M; Piérard, D; Ruelle, J; Vaira, D; Vandercam, B; Van Ranst, M; Van Wijngaerden, E; Vandekerckhove, L; Verhofstede, C

    2016-03-01

    In 2011, a consensus was reached defining "late presenters" (LPs) as individuals presenting for care with a CD4 count < 350 cells/μL or with an AIDS-defining event, regardless of CD4 count. However, a transient low CD4 count is not uncommon in recent infections. The objective of this study was to investigate how measurements of late presentation change if the clinical stage at the time of diagnosis is taken into account. Case surveillance data for newly diagnosed patients in Belgium in 1998-2012 were analysed, including CD4 count at diagnosis, the presence of AIDS-defining events, and recent infections (< 6 months) as reported by clinicians in the case of acute illness or a recent negative test. First, proportions of LPs were calculated according to the consensus definition. Secondly, LPs were reclassified as "nonlate" if infections were reported as recent. A total of 7949 HIV diagnoses were included in the study. Recent infections were increasingly reported over time, accounting for 8.2% of new infections in 1998 and 37.5% in 2012. The consideration of clinical stage significantly modified the proportion of LPs: 18.2% of men who have sex with men (MSM) diagnosed in 2012 would be classified as LPs instead of 30.9% using the consensus definition (P < 0.001). The proportion of patients misclassified as LPs increased significantly over time: 5% in MSM in 1998 vs. 41% in 2012. This study suggests that low CD4 counts in recent infections may lead to overestimation of late presentation when applying the consensus definition. The impact of transient CD4 count on late presentation estimates should be assessed and, if relevant, the introduction of clinical stage in the definition of late presentation should be considered. © 2015 British HIV Association.

  2. Meteorology and the physical activity of the elderly: the Nakanojo Study

    NASA Astrophysics Data System (ADS)

    Togo, Fumiharu; Watanabe, Eiji; Park, Hyuntae; Shephard, Roy J.; Aoyagi, Yukitoshi

    2005-11-01

    Seasonal changes in ambient temperature and day length are thought to modify habitual physical activity. However, relationships between such environmental factors and the daily physical activity of older populations remain unclear. The present study thus examined associations between meteorological variables and the number of steps taken per day by elderly Japanese. Continuous pedometer counts over a 450-day period were collected from 41 healthy subjects (age 71±4 years), none of whom engaged in any specific occupational activity or exercise programs. An electronic physical activity monitor was attached to a belt worn on the left side of the body throughout the day. Daily values for mean ambient temperature, duration of bright sunshine, mean wind speed, mean relative humidity, and precipitation were obtained from local meteorological stations. The day length was calculated from times of sunrise and sunset. Based on the entire group of 41 subjects (ensemble average), a subject’s step count per day decreased exponentially with increasing precipitation (r2=0.19, P<0.05). On days when precipitation was <1 mm, the step count increased with the mean ambient temperature over the range of 2 to 17°C, but decreased over the range 17 29°C. The daily step count also tended to increase with day length, but the regression coefficient of determination attributable to step count and mean ambient temperature (r2=0.32, P<0.05) exceeded that linking the step count and day length (r2=0.13, P<0.05). The influence of other meteorological factors was small (r2≤0.03) and of little practical significance. On days when precipitation is <1 mm, physical activity is associated more strongly with ambient temperature than with day length, duration of bright sunshine, wind speed, or relative humidity. Our findings have practical implications for health promotion efforts designed to increase the physical activity of elderly people consistently in the face of seasonal variations in environmental conditions.

  3. Economic Analysis of Redesign Alternatives for the RESFMS Information System

    DTIC Science & Technology

    1992-09-01

    input parameters to produce the variations of output ( Pressman , 1992). Thus, if system maintenance dictates that the procedure needs to be modified, it...easily counted, and that "a large body of literature and data predicated on LOC already exists." ( Pressman , 1992) Another term for LOC, used by Boehm... Pressman , 1992). 54 D. FUNCTION POINTS An alternative to size metrics such as LOC is the measurement of software "functionality" or "utility." Function

  4. Microfluidic platform integrated with worm-counting setup for assessing manganese toxicity

    PubMed Central

    Zhang, Beibei; Li, Yinbao; He, Qidi; Qin, Jun; Yu, Yanyan; Li, Xinchun; Zhang, Lin; Yao, Meicun; Liu, Junshan; Chen, Zuanguang

    2014-01-01

    We reported a new microfluidic system integrated with worm responders for evaluating the environmental manganese toxicity. The micro device consists of worm loading units, worm observing chambers, and a radial concentration gradient generator (CGG). Eight T-shape worm loading units of the micro device were used to load the exact number of worms into the corresponding eight chambers with the assistance of worm responders and doorsills. The worm responder, as a key component, was employed for performing automated worm-counting assay through electric impedance sensing. This label-free and non-invasive worm-counting technique was applied to the microsystem for the first time. In addition, the disk-shaped CGG can generate a range of stepwise concentrations of the appointed chemical automatically and simultaneously. Due to the scalable architecture of radial CGG, it has the potential to increase the throughput of the assay. Dopaminergic (DAergic) neurotoxicity of manganese on C. elegans was quantitatively assessed via the observation of green fluorescence protein-tagged DAergic neurons of the strain BZ555 on-chip. In addition, oxidative stress triggered by manganese was evaluated by the quantitative fluorescence intensity of the strain CL2166. By scoring the survival ratio and stroke frequency of worms, we characterized the dose- and time-dependent mobility defects of the manganese-exposed worms. Furthermore, we applied the microsystem to investigate the effect of natural antioxidants to protect manganese-induced toxicity. PMID:25538805

  5. Active books: the design of an implantable stimulator that minimizes cable count using integrated circuits very close to electrodes.

    PubMed

    Liu, Xiao; Demosthenous, Andreas; Vanhoestenberghe, Anne; Jiang, Dai; Donaldson, Nick

    2012-06-01

    This paper presents an integrated stimulator that can be embedded in implantable electrode books for interfacing with nerve roots at the cauda equina. The Active Book overcomes the limitation of conventional nerve root stimulators which can only support a small number of stimulating electrodes due to cable count restriction through the dura. Instead, a distributed stimulation system with many tripole electrodes can be configured using several Active Books which are addressed sequentially. The stimulator was fabricated in a 0.6-μm high-voltage CMOS process and occupies a silicon area of 4.2 × 6.5 mm(2). The circuit was designed to deliver up to 8 mA stimulus current to tripole electrodes from an 18 V power supply. Input pad count is limited to five (two power and three control lines) hence requiring a specific procedure for downloading stimulation commands to the chip and extracting information from it. Supported commands include adjusting the amplitude of stimulus current, varying the current ratio at the two anodes in each channel, and measuring relative humidity inside the chip package. In addition to stimulation mode, the chip supports quiescent mode, dissipating less than 100 nA current from the power supply. The performance of the stimulator chip was verified with bench tests including measurements using tripoles in saline.

  6. Effect of ingestion of soy yogurt on intestinal parameters of rats fed on a beef-based animal diet

    PubMed Central

    Bedani, Raquel; Pauly-Silveira, Nadiége Dourado; Cano, Veridiana Soares Pereira; Valentini, Sandro Roberto; de Rossi, Graciela Font; Valdez, Elizeu Antonio

    2011-01-01

    The aim of this study was to investigate whether the ingestion of soy yogurt fermented with Enterococcus faecium CRL 183 would modify the intestinal count of enterococci, fecal pH and ammonia content in rats fed on a diet containing red meat. The rats were placed in 4 groups: for 60 days, group I was given a standard casein-based rodent feed and groups II-IV, the beef-based feed. From day 30, groups III-IV also received the following products: III) soy yogurt; IV) suspension of E. faecium CRL 183. At the start and on days 30 and 60, feces were collected for the determination of pH, ammonia content, count of enterococci and identification of their species. On day 60, rats were sacrificed and their colons also removed for count of enterococci and identification of their species. Rats that ingested soy yogurt showed no significant change (P<0.05) in fecal counts of Enterococcus spp., but, this rat group showed a higher count of E. faecium than rats that ingested suspension of E. faecium CRL 183. The ingestion of soy yogurt and E. faecium culture caused a significant rise (P < 0.05) in fecal pH and ammonia content. Our results suggest that consumption of soy yogurt fermented with E. faecium CRL 183 and L. helveticus subsp. jugurti could change the species of Enterococcus spp. present in the feces and colon of rats fed on a beef-based diet. However, the fermented soy product and the pure culture of E. faecium CRL 183 also induced undesirable effects such as the increase of fecal pH and ammonia content in the feces of rats fed on a beef-based diet. PMID:24031747

  7. Influence of meteorological parameters and air pollution on hourly fluctuation of birch (Betula L.) and ash (Fraxinus L.) airborne pollen.

    PubMed

    Puc, Małgorzata

    2012-01-01

    Pollen grains are one of the most important groups of atmospheric biological particles that originate allergic processes. Knowledge of intradiurnal variation of the atmospheric pollen may be useful for the treatment and prevention of pollen allergies. Intradiurnal fluctuation of hourly pollen counts in 24 h are related to the daily rhythm of anther opening, and modified by various interacting factors. Flowering and pollen production of individual species are influenced by genetic, phenological, ecological, meteorological and climatic factors. Estimation of the intradiurnal variability in the pollen count permits evaluation of the threat posed by allergens over a given area. Measurements performed in Szczecin over a period of 7 years (2006-2012) permitted analysis of hourly variation of the pollen count of birch (Betula) and ash (Fraxinus) in 24 h, and evaluation of the impact of weather conditions and the concentration of gas air pollutants on the intradiurnal patterns of both taxa. Aerobiological monitoring was conducted using a Hirst volumetric trap (Lanzoni VPPS 2000). Consecutive phases during the day were defined as 1, 5, 25, 50, 75, 95, 99% of annual total pollen. The analysis revealed that 50% of total daily pollen was noted at 14:00 for Betula and Fraxinus. The hourly distribution of birch pollen count skewed to the left and the majority of pollen of this taxon appears in the air in the first 12 hours of the day. However, for ash, the hourly distribution of pollen count skewed to the right. Statistically significant correlation was noted between the Betula and Fraxinus pollen concentration and the mean air temperature, relative humidity, wind speed, air pressure, total radiation and nitrogen oxides (NO(x)).

  8. In search for a gold-standard procedure to count motor neurons in the spinal cord.

    PubMed

    Ferrucci, Michela; Lazzeri, Gloria; Flaibani, Marina; Biagioni, Francesca; Cantini, Federica; Madonna, Michele; Bucci, Domenico; Limanaqi, Fiona; Soldani, Paola; Fornai, Francesco

    2018-03-14

    Counting motor neurons within the spinal cord and brainstem represents a seminal step to comprehend the anatomy and physiology of the final common pathway sourcing from the CNS. Motor neuron loss allows to assess the severity of motor neuron disorders while providing a tool to assess disease modifying effects. Counting motor neurons at first implies gold standard identification methods. In fact, motor neurons may occur within mixed nuclei housing a considerable amount of neurons other than motor neurons. In the present review, we analyse various approaches to count motor neurons emphasizing both the benefits and bias of each protocol. A special emphasis is placed on discussing automated stereology. When automated stereology does not take into account site-specificity and does not distinguish between heterogeneous neuronal populations, it may confound data making such a procedure a sort of "guide for the perplex". Thus, if on the one hand automated stereology improves our ability to quantify neuronal populations, it may also hide false positives/negatives in neuronal counts. For instance, classic staining for antigens such as SMI-32, SMN and ChAT, which are routinely considered to be specific for motor neurons, may also occur in other neuronal types of the spinal cord. Even site specificity within Lamina IX may be misleading due to neuronal populations having a size and shape typical of motor neurons. This is the case of spinal border cells, which often surpass the border of Lamina VII and intermingle with motor neurons of Lamina IX. The present article discusses the need to join automated stereology with a dedicated knowledge of each specific neuroanatomical setting.

  9. A big data approach to the development of mixed-effects models for seizure count data.

    PubMed

    Tharayil, Joseph J; Chiang, Sharon; Moss, Robert; Stern, John M; Theodore, William H; Goldenholz, Daniel M

    2017-05-01

    Our objective was to develop a generalized linear mixed model for predicting seizure count that is useful in the design and analysis of clinical trials. This model also may benefit the design and interpretation of seizure-recording paradigms. Most existing seizure count models do not include children, and there is currently no consensus regarding the most suitable model that can be applied to children and adults. Therefore, an additional objective was to develop a model that accounts for both adult and pediatric epilepsy. Using data from SeizureTracker.com, a patient-reported seizure diary tool with >1.2 million recorded seizures across 8 years, we evaluated the appropriateness of Poisson, negative binomial, zero-inflated negative binomial, and modified negative binomial models for seizure count data based on minimization of the Bayesian information criterion. Generalized linear mixed-effects models were used to account for demographic and etiologic covariates and for autocorrelation structure. Holdout cross-validation was used to evaluate predictive accuracy in simulating seizure frequencies. For both adults and children, we found that a negative binomial model with autocorrelation over 1 day was optimal. Using holdout cross-validation, the proposed model was found to provide accurate simulation of seizure counts for patients with up to four seizures per day. The optimal model can be used to generate more realistic simulated patient data with very few input parameters. The availability of a parsimonious, realistic virtual patient model can be of great utility in simulations of phase II/III clinical trials, epilepsy monitoring units, outpatient biosensors, and mobile Health (mHealth) applications. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  10. Severe Infections are Common in Thiamine Deficiency and May be Related to Cognitive Outcomes: A Cohort Study of 68 Patients With Wernicke-Korsakoff Syndrome.

    PubMed

    Wijnia, Jan W; Oudman, Erik; van Gool, Willem A; Wierdsma, André I; Bresser, Esmay L; Bakker, Jan; van de Wiel, Albert; Mulder, Cornelis L

    Wernicke encephalopathy can have different clinical outcomes. Although infections may precipitate the encephalopathy itself, it is unknown whether infections also modify the long-term outcome in patients developing Korsakoff syndrome. To determine whether markers of infection, such as white blood cell (WBC) counts and absolute neutrophil counts in the Wernicke phase, are associated with cognitive outcomes in the end-stage Korsakoff syndrome. Retrospective, descriptive study of patients admitted to Slingedael Korsakoff Center, Rotterdam, The Netherlands. Hospital discharge letters of patients with Wernicke encephalopathy were searched for relevant data on infections present upon hospital admission. Patients were selected for further analysis if data were available on WBC counts in the Wernicke phase and at least 1 of 6 predefined neuropsychological tests on follow-up. Infections were reported in 35 of 68 patients during the acute phase of Wernicke-Korsakoff syndrome-meningitis (1), pneumonia (14), urinary tract infections (9), acute abdominal infections (4), sepsis (5) empyema, (1) and infection "of unknown origin" (4). The neuropsychological test results showed significant lower scores on the Cambridge Cognitive Examination nonmemory section with increasing white blood cell counts (Spearman rank correlation, ρ = -0.34; 95% CI: -0.57 to -0.06; 44 patients) and on the "key search test" of the behavioral assessment of the dysexecutive syndrome with increasing absolute neutrophil counts (ρ= -0.85; 95% CI: -0.97 to -0.42; 9 patients). Infections may be the presenting manifestation of thiamine deficiency. Patients with Wernicke-Korsakoff syndrome who suffered from an infection during the acute phase are at risk of worse neuropsychological outcomes on follow-up. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  11. Combined chitosan-thyme treatments with modified atmosphere packaging on a ready-to-cook poultry product.

    PubMed

    Giatrakou, V; Ntzimani, A; Savvaidis, I N

    2010-04-01

    In the present study, natural antimicrobials chitosan and thyme, and their combination, were evaluated for their effect on the shelf life of a ready-to-cook (RTC) chicken-pepper kebab (skewer) stored under modified atmosphere packaging (MAP) conditions at 4 +/- 0.5 degrees C for 14 days. The following treatments were examined: control samples stored under aerobic packaging (A), samples stored under MAP (M), samples treated with 1.5% chitosan (vol/wt) and stored under MAP (M-CH), samples treated with 0.2% thyme essential oil (vol/wt) (M-T), and samples treated with 1.5% chitosan (vol/wt) and 0.2% thyme essential oil (vol/wt) and stored under MAP (M-CH-T). Treatment M-CH-T significantly affected aerobic plate counts and counts of lactic acid bacteria, Pseudomonas spp., Brochothrix thermosphacta, Enterobacteriaceae, and yeasts and molds during the entire storage period. Similarly, lipid oxidation of the RTC product was retarded (M-CH-T treatment) during storage, whereas redness was maintained in M-T, M-CH, and M-CH-T samples. Based primarily on sensory data (taste attribute), M-CH and M-T treatments extended RTC product shelf life by 6 days, whereas M-CH-T treatment resulted in a product with a shelf life of 14 days that maintained acceptable sensory characteristics (shelf life of the control was 6 days).

  12. Integral transformation solution of free-space cylindrical vector beams and prediction of modified Bessel-Gaussian vector beams.

    PubMed

    Li, Chun-Fang

    2007-12-15

    A unified description of free-space cylindrical vector beams is presented that is an integral transformation solution to the vector Helmholtz equation and the transversality condition. In the paraxial condition, this solution not only includes the known J(1) Bessel-Gaussian vector beam and the axisymmetric Laguerre-Gaussian vector beam that were obtained by solving the paraxial wave equations but also predicts two kinds of vector beam, called a modified Bessel-Gaussian vector beam.

  13. Dopaminergic stimulation in unilateral neglect

    PubMed Central

    Geminiani, G.; Bottini, G.; Sterzi, R.

    1998-01-01

    OBJECTIVE—To explore the hypothesis that dopaminergic circuits play a part in the premotor components of the unilateral neglect syndrome, the effects of acute dopaminergic stimulation in patients with neglect were studied.
METHODS—Two tasks were evaluated before and after subcutaneous administration of apomorphine and placebo: a circle crossing test and a test of target exploration (a modified version of the bell test), performed both in perceptual (counting) and in perceptual-motor (pointing) conditions.
SUBJECTS—Four patients with left neglect.
RESULTS—After dopaminergic stimulation, a significant improvement was found compared with placebo administration and baseline evaluation, in the performance of the two tests. Three of the patients had a more marked improvement in the perceptual-motor condition (pointing) of the task than the perceptual condition (counting).
CONCLUSIONS—The findings suggest that dopaminergic neuronal networks may mediate, in different ways, both perceptive and premotor components of the unilateral neglect syndrome. 

 PMID:9728946

  14. Caffeine and Insomnia in People Living With HIV From the Miami Adult Studies on HIV (MASH) Cohort.

    PubMed

    Ramamoorthy, Venkataraghavan; Campa, Adriana; Rubens, Muni; Martinez, Sabrina S; Fleetwood, Christina; Stewart, Tiffanie; Liuzzi, Juan P; George, Florence; Khan, Hafiz; Li, Yinghui; Baum, Marianna K

    We explored the relationship between caffeine consumption, insomnia, and HIV disease progression (CD4+ T cell counts and HIV viral loads). Caffeine intake and insomnia levels were measured using the Modified Caffeine Consumption Questionnaire and the Pittsburgh Insomnia Rating Scale (PIRS) in 130 clinically stable participants who were living with HIV, taking antiretroviral therapy, and recruited from the Miami Adult Studies on HIV cohort. Linear regressions showed that caffeine consumption was significantly and adversely associated with distress score, quality-of-life score, and global PIRS score. Linear regression analyses also showed that global PIRS score was significantly associated with lower CD4+ T cell counts and higher HIV viral loads. Caffeine could have precipitated insomnia in susceptible people living with HIV, which could be detrimental to their disease progression states. Copyright © 2017 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  15. Epistemological depth in a GM crops controversy.

    PubMed

    Hicks, Daniel J

    2015-04-01

    This paper examines the scientific controversy over the yields of genetically modified [GM] crops as a case study in epistemologically deep disagreements. Appeals to "the evidence" are inadequate to resolve such disagreements; not because the interlocutors have radically different metaphysical views (as in cases of incommensurability), but instead because they assume rival epistemological frameworks and so have incompatible views about what kinds of research methods and claims count as evidence. Specifically, I show that, in the yield debate, proponents and opponents of GM crops cite two different sets of claims as evidence, which correspond to two rival epistemological frameworks, classical experimental epistemology and Nancy Cartwright's evidence for use. I go on to argue that, even if both sides of the debate accepted Cartwright's view, they might still disagree over what counts as evidence, because evidence for use ties standards of evidence to what is sometimes called the "context of application." Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Effects of short-term hypothermal and contrast exposure on immunophysiological parameters of laboratory animals.

    PubMed

    Kalenova, L F; Fisher, T A; Suhovey, J G; Besedin, I M

    2009-05-01

    Experiments on inbred animals showed that short-term exposure in cold water significantly modified structural and functional parameters of the immune system at different levels of its organization, from bone marrow hemopoiesis to effector stage of the immune response to antigen. The thermal factor caused changes in nonspecific and specific mechanisms of the immune system. Hypothermal exposure (7-9 degrees C, 5 sec) increased the thymic index and bone marrow lymphocyte count, reduced absorption capacity and stimulated metabolic activity of phagocytes, stimulated cell-mediated and suppressed humoral immunity. Contrast exposure in cold and hot water (7-9 degrees C, 5 sec/40-42 degrees C, 30 sec) increased monocyte count in bone marrow and reduced it in the their peripheral blood, reduced metabolic activity of phagocytes, stimulated cell-mediated and suppressed humoral immunity. These data demonstrate physiological mechanisms of interactions between the thermoregulatory and immune systems.

  17. Integrator Windup Protection-Techniques and a STOVL Aircraft Engine Controller Application

    NASA Technical Reports Server (NTRS)

    KrishnaKumar, K.; Narayanaswamy, S.

    1997-01-01

    Integrators are included in the feedback loop of a control system to eliminate the steady state errors in the commanded variables. The integrator windup problem arises if the control actuators encounter operational limits before the steady state errors are driven to zero by the integrator. The typical effects of windup are large system oscillations, high steady state error, and a delayed system response following the windup. In this study, methods to prevent the integrator windup are examined to provide Integrator Windup Protection (IW) for an engine controller of a Short Take-Off and Vertical Landing (STOVL) aircraft. An unified performance index is defined to optimize the performance of the Conventional Anti-Windup (CAW) and the Modified Anti-Windup (MAW) methods. A modified Genetic Algorithm search procedure with stochastic parameter encoding is implemented to obtain the optimal parameters of the CAW scheme. The advantages and drawbacks of the CAW and MAW techniques are discussed and recommendations are made for the choice of the IWP scheme, given some characteristics of the system.

  18. Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.

    PubMed

    Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M

    2013-02-01

    This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner reduced environmental pathogens in sawdust bedding and teat ends without affecting teat end integrity. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Field reliability of Ricor microcoolers

    NASA Astrophysics Data System (ADS)

    Pundak, N.; Porat, Z.; Barak, M.; Zur, Y.; Pasternak, G.

    2009-05-01

    Over the recent 25 years Ricor has fielded in excess of 50,000 Stirling cryocoolers, among which approximately 30,000 units are of micro integral rotary driven type. The statistical population of the fielded units is counted in thousands/ hundreds per application category. In contrast to MTTF values as gathered and presented based on standard reliability demonstration tests, where the failure of the weakest component dictates the end of product life, in the case of field reliability, where design and workmanship failures are counted and considered, the values are usually reported in number of failures per million hours of operation. These values are important and relevant to the prediction of service capabilities and plan.

  20. Integrated analysis on static/dynamic aeroelasticity of curved panels based on a modified local piston theory

    NASA Astrophysics Data System (ADS)

    Yang, Zhichun; Zhou, Jian; Gu, Yingsong

    2014-10-01

    A flow field modified local piston theory, which is applied to the integrated analysis on static/dynamic aeroelastic behaviors of curved panels, is proposed in this paper. The local flow field parameters used in the modification are obtained by CFD technique which has the advantage to simulate the steady flow field accurately. This flow field modified local piston theory for aerodynamic loading is applied to the analysis of static aeroelastic deformation and flutter stabilities of curved panels in hypersonic flow. In addition, comparisons are made between results obtained by using the present method and curvature modified method. It shows that when the curvature of the curved panel is relatively small, the static aeroelastic deformations and flutter stability boundaries obtained by these two methods have little difference, while for curved panels with larger curvatures, the static aeroelastic deformation obtained by the present method is larger and the flutter stability boundary is smaller compared with those obtained by the curvature modified method, and the discrepancy increases with the increasing of curvature of panels. Therefore, the existing curvature modified method is non-conservative compared to the proposed flow field modified method based on the consideration of hypersonic flight vehicle safety, and the proposed flow field modified local piston theory for curved panels enlarges the application range of piston theory.

  1. What Is the Role of Manual Preference in Hand-Digit Mapping During Finger Counting? A Study in a Large Sample of Right- and Left-Handers.

    PubMed

    Zago, Laure; Badets, Arnaud

    2016-01-01

    The goal of the present study was to test whether there is a relationship between manual preference and hand-digit mapping in 369 French adults with similar numbers of right- and left-handers. Manual laterality was evaluated with the finger tapping test to evaluate hand motor asymmetry, and the Edinburgh handedness inventory was used to assess manual preference strength (MPS) and direction. Participants were asked to spontaneously "count on their fingers from 1 to 10" without indications concerning the hand(s) to be used. The results indicated that both MPS and hand motor asymmetry affect the hand-starting preference for counting. Left-handers with a strong left-hand preference (sLH) or left-hand motor asymmetry largely started to count with their left hand (left-starter), while right-handers with a strong right-hand preference (sRH) or right-hand motor asymmetry largely started to count with their right hand (right-starter). Notably, individuals with weak MPS did not show a hand-starting preference. These findings demonstrated that manual laterality contributes to finger counting directionality. Lastly, the results showed a higher proportion of sLH left-starter individuals compared with sRH right-starters, indicating an asymmetric bias of MPS on hand-starting preference. We hypothesize that the higher proportion of sLH left-starters could be explained by the congruence between left-to-right hand-digit mapping and left-to-right mental number line representation that has been largely reported in the literature. Taken together, these results indicate that finger-counting habits integrate biological and cultural information. © The Author(s) 2015.

  2. Evaluating and improving count-based population inference: A case study from 31 years of monitoring Sandhill Cranes

    USGS Publications Warehouse

    Gerber, Brian D.; Kendall, William L.

    2017-01-01

    Monitoring animal populations can be difficult. Limited resources often force monitoring programs to rely on unadjusted or smoothed counts as an index of abundance. Smoothing counts is commonly done using a moving-average estimator to dampen sampling variation. These indices are commonly used to inform management decisions, although their reliability is often unknown. We outline a process to evaluate the biological plausibility of annual changes in population counts and indices from a typical monitoring scenario and compare results with a hierarchical Bayesian time series (HBTS) model. We evaluated spring and fall counts, fall indices, and model-based predictions for the Rocky Mountain population (RMP) of Sandhill Cranes (Antigone canadensis) by integrating juvenile recruitment, harvest, and survival into a stochastic stage-based population model. We used simulation to evaluate population indices from the HBTS model and the commonly used 3-yr moving average estimator. We found counts of the RMP to exhibit biologically unrealistic annual change, while the fall population index was largely biologically realistic. HBTS model predictions suggested that the RMP changed little over 31 yr of monitoring, but the pattern depended on assumptions about the observational process. The HBTS model fall population predictions were biologically plausible if observed crane harvest mortality was compensatory up to natural mortality, as empirical evidence suggests. Simulations indicated that the predicted mean of the HBTS model was generally a more reliable estimate of the true population than population indices derived using a moving 3-yr average estimator. Practitioners could gain considerable advantages from modeling population counts using a hierarchical Bayesian autoregressive approach. Advantages would include: (1) obtaining measures of uncertainty; (2) incorporating direct knowledge of the observational and population processes; (3) accommodating missing years of data; and (4) forecasting population size.

  3. Shelf-life extension of cod fillets with an acetate buffer spray prior to packaging under modified atmospheres.

    PubMed

    Boskou, G; Debevere, J

    2000-01-01

    Fresh cod fillets (Gadus morhua) were sprayed with a 10% acetate buffer (pH 5.6), packed with an industrial gas-flushing packaging machine under modified atmospheres (50% CO2--45% O2--5% N2, 2 cm3/1 g gas/product ratio) and stored at 7 degrees C for 12 days. Control cod fillets were directly packed and stored under the same conditions. A reduction of the aerobic plate counts was observed immediately after the cod fillets had been sprayed. During storage under modified atmospheres, there was complete inhibition of H2S-producing bacteria and Enterobacteriaceae in the treated cod fillets. Production of total volatile bases and trimethylamine (TMA) was inhibited in treated fillets for 10 days' storage under modified atmospheres. Inhibition of TMA production can be attributed to growth inhibition of H2S-producing bacteria, inhibition of the trimethylamine oxide (TMAO)-dependent metabolism of TMAO-reducing bacteria and the stable pH during storage. The shelf-life, at 7 degrees C, of treated cod fillets, based on cooked flavour score, was almost 12 days, ca 8 days more than shelf-life of the control fillets.

  4. Facilities Management via Computer: Information at Your Fingertips.

    ERIC Educational Resources Information Center

    Hensey, Susan

    1996-01-01

    Computer-aided facilities management is a software program consisting of a relational database of facility information--such as occupancy, usage, student counts, etc.--attached to or merged with computerized floor plans. This program can integrate data with drawings, thereby allowing the development of "what if" scenarios. (MLF)

  5. Effective Language for Communicating Children's Issues.

    ERIC Educational Resources Information Center

    Coalition for America's Children, Washington, DC.

    Maintaining that only by integrating communications into program planning and policy can Kids Count grantees and other child advocates achieve their goals, this document presents four studies examining the ways in which the media currently frame children's issues, the consequences of those frames, and possibilities for reframing media depictions…

  6. Circulating endothelial cells as marker of endothelial damage in male hypogonadism.

    PubMed

    Milardi, Domenico; Grande, Giuseppe; Giampietro, Antonella; Vendittelli, Francesca; Palumbo, Sara; Tartaglione, Linda; Marana, Riccardo; Pontecorvi, Alfredo; de Marinis, Laura; Zuppi, Cecilia; Capoluongo, Ettore

    2012-01-01

    Testosterone deficiency has become a frequently diagnosed condition in today's society affected by epidemic obesity, and is associated with cardiovascular risk. Recent studies have established the importance of altered vascular endothelium function in cardiovascular disease. The damage to the endothelium might also cause endothelial cell detachment, resulting in increased numbers of circulating endothelial cells (CEC) within the bloodstream. To evaluate whether hypogonadism could modify CEC count in peripheral bloodstream, we investigated peripheral blood CEC count using the CellSearch System, a semiautomatic method to accurately and reliably enumerate CECs, which are sorted based on a CD146(+), CD105(+), DAPI(+), CD45(-) phenotype, in a population of 20 patients with hypogonadism. The control group comprised 10 age- and sex-matched healthy participants. CEC count per milliliter was significantly increased in patients with hypogonadism vs the control group. In the group with hypogonadism, an inverse exponential correlation was present between testosterone levels and CEC count per milliliter. A direct linear correlation was present between waist circumference and CECs and between body mass index and CECs. The regression analysis showed that testosterone was the significant independent determinant of CECs. Our results underline that male hypogonadism is associated with endothelial dysfunction. The correlation between CEC and waist circumference underlines that visceral obesity may be synergically implicated in this regulation. Future studies are required to unveil the mechanisms involved in the pathogenesis of testosterone-induced endothelial disfunction, which may provide novel therapeutic targets to be incorporated in the management of hypogonadism.

  7. Hematological Profile and Martial Status in Rugby Players during Whole Body Cryostimulation

    PubMed Central

    Lombardi, Giovanni; Lanteri, Patrizia; Porcelli, Simone; Mauri, Clara; Colombini, Alessandra; Grasso, Dalila; Zani, Viviana; Bonomi, Felice Giulio; Melegati, Gianluca; Banfi, Giuseppe

    2013-01-01

    Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (−110°C to −140°C). Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers. PMID:23383348

  8. Predicting nurses' use of healthcare technology using the technology acceptance model: an integrative review.

    PubMed

    Strudwick, Gillian

    2015-05-01

    The benefits of healthcare technologies can only be attained if nurses accept and intend to fully use them. One of the most common models utilized to understand user acceptance of technology is the Technology Acceptance Model. This model and modified versions of it have only recently been applied in the healthcare literature among nurse participants. An integrative literature review was conducted on this topic. Ovid/MEDLINE, PubMed, Google Scholar, and CINAHL were searched yielding a total of 982 references. Upon eliminating duplicates and applying the inclusion and exclusion criteria, the review included a total of four dissertations, three symposium proceedings, and 13 peer-reviewed journal articles. These documents were appraised and reviewed. The results show that a modified Technology Acceptance Model with added variables could provide a better explanation of nurses' acceptance of healthcare technology. These added variables to modified versions of the Technology Acceptance Model are discussed, and the studies' methodologies are critiqued. Limitations of the studies included in the integrative review are also examined.

  9. Wavelet principal component analysis of fetal movement counting data preceding hospital examinations due to decreased fetal movement: a prospective cohort study

    PubMed Central

    2013-01-01

    Background Fetal movement (FM) counting is a simple and widely used method of assessing fetal well-being. However, little is known about what women perceive as decreased fetal movement (DFM) and how maternally perceived DFM is reflected in FM charts. Methods We analyzed FM counting data from 148 DFM events occurring in 137 pregnancies. The women counted FM daily from pregnancy week 24 until birth using a modified count-to-ten procedure. Common temporal patterns for the two weeks preceding hospital examination due to DFM were extracted from the FM charts using wavelet principal component analysis; a statistical methodology particularly developed for modeling temporal data with sudden changes, i.e. spikes that are frequently found in FM data. The association of the extracted temporal patterns with fetal complications was assessed by including the individuals’ scores on the wavelet principal components as explanatory variables in multivariable logistic regression analyses for two outcome measures: (i) complications identified during DFM-related consultations (n = 148) and (ii) fetal compromise at the time of consultation (including relevant information about birth outcome and placental pathology). The latter outcome variable was restricted to the DFM events occurring within 21 days before birth (n = 76). Results Analyzing the 148 and 76 DFM events, the first three main temporal FM counting patterns explained 87.2% and 87.4%, respectively, of all temporal variation in the FM charts. These three temporal patterns represented overall counting times, sudden spikes around the time of DFM events, and an inverted U-shaped pattern, explaining 75.3%, 8.6%, and 3.3% and 72.5%, 9.6%, and 5.3% of variation in the total cohort and subsample, respectively. Neither of the temporal patterns was significantly associated with the two outcome measures. Conclusions Acknowledging that sudden, large changes in fetal activity may be underreported in FM charts, our study showed that the temporal FM counting patterns in the two weeks preceding DFM-related consultation contributed little to identify clinically important changes in perceived FM. It thus provides insufficient information for giving detailed advice to women on when to contact health care providers. The importance of qualitative features of maternally perceived DFM should be further explored. PMID:24007565

  10. Wavelet principal component analysis of fetal movement counting data preceding hospital examinations due to decreased fetal movement: a prospective cohort study.

    PubMed

    Winje, Brita Askeland; Røislien, Jo; Saastad, Eli; Eide, Jorid; Riley, Christopher Finne; Stray-Pedersen, Babill; Frøen, J Frederik

    2013-09-05

    Fetal movement (FM) counting is a simple and widely used method of assessing fetal well-being. However, little is known about what women perceive as decreased fetal movement (DFM) and how maternally perceived DFM is reflected in FM charts. We analyzed FM counting data from 148 DFM events occurring in 137 pregnancies. The women counted FM daily from pregnancy week 24 until birth using a modified count-to-ten procedure. Common temporal patterns for the two weeks preceding hospital examination due to DFM were extracted from the FM charts using wavelet principal component analysis; a statistical methodology particularly developed for modeling temporal data with sudden changes, i.e. spikes that are frequently found in FM data. The association of the extracted temporal patterns with fetal complications was assessed by including the individuals' scores on the wavelet principal components as explanatory variables in multivariable logistic regression analyses for two outcome measures: (i) complications identified during DFM-related consultations (n = 148) and (ii) fetal compromise at the time of consultation (including relevant information about birth outcome and placental pathology). The latter outcome variable was restricted to the DFM events occurring within 21 days before birth (n = 76). Analyzing the 148 and 76 DFM events, the first three main temporal FM counting patterns explained 87.2% and 87.4%, respectively, of all temporal variation in the FM charts. These three temporal patterns represented overall counting times, sudden spikes around the time of DFM events, and an inverted U-shaped pattern, explaining 75.3%, 8.6%, and 3.3% and 72.5%, 9.6%, and 5.3% of variation in the total cohort and subsample, respectively. Neither of the temporal patterns was significantly associated with the two outcome measures. Acknowledging that sudden, large changes in fetal activity may be underreported in FM charts, our study showed that the temporal FM counting patterns in the two weeks preceding DFM-related consultation contributed little to identify clinically important changes in perceived FM. It thus provides insufficient information for giving detailed advice to women on when to contact health care providers. The importance of qualitative features of maternally perceived DFM should be further explored.

  11. Numerical integration of ordinary differential equations of various orders

    NASA Technical Reports Server (NTRS)

    Gear, C. W.

    1969-01-01

    Report describes techniques for the numerical integration of differential equations of various orders. Modified multistep predictor-corrector methods for general initial-value problems are discussed and new methods are introduced.

  12. AthenaMT: upgrading the ATLAS software framework for the many-core world with multi-threading

    NASA Astrophysics Data System (ADS)

    Leggett, Charles; Baines, John; Bold, Tomasz; Calafiura, Paolo; Farrell, Steven; van Gemmeren, Peter; Malon, David; Ritsch, Elmar; Stewart, Graeme; Snyder, Scott; Tsulaia, Vakhtang; Wynne, Benjamin; ATLAS Collaboration

    2017-10-01

    ATLAS’s current software framework, Gaudi/Athena, has been very successful for the experiment in LHC Runs 1 and 2. However, its single threaded design has been recognized for some time to be increasingly problematic as CPUs have increased core counts and decreased available memory per core. Even the multi-process version of Athena, AthenaMP, will not scale to the range of architectures we expect to use beyond Run2. After concluding a rigorous requirements phase, where many design components were examined in detail, ATLAS has begun the migration to a new data-flow driven, multi-threaded framework, which enables the simultaneous processing of singleton, thread unsafe legacy Algorithms, cloned Algorithms that execute concurrently in their own threads with different Event contexts, and fully re-entrant, thread safe Algorithms. In this paper we report on the process of modifying the framework to safely process multiple concurrent events in different threads, which entails significant changes in the underlying handling of features such as event and time dependent data, asynchronous callbacks, metadata, integration with the online High Level Trigger for partial processing in certain regions of interest, concurrent I/O, as well as ensuring thread safety of core services. We also report on upgrading the framework to handle Algorithms that are fully re-entrant.

  13. Evaluation of antibacterial properties of novel phthalocyanines against Escherichia coli--comparison of analytical methods.

    PubMed

    Mikula, Premysl; Kalhotka, Libor; Jancula, Daniel; Zezulka, Stepan; Korinkova, Radka; Cerny, Jiri; Marsalek, Blahoslav; Toman, Petr

    2014-09-05

    We analyzed antibacterial effects of several novel phthalocyanines against Escherichia coli and evaluated the suitability of flow cytometry for the detection of antibacterial effects of phthalocyanines in comparison with routinely used cultivation. After 3h of exposure under cool white light eight cationic phthalocyanines showed very high antibacterial activity in the concentration of 2.00 mg L(-1) and four of them were even efficient in the concentration of 0.20 mg L(-1). Antibacterial activity of neutral and anionic compounds was considerably lower or even negligible. No antibacterial effect was detected when bacteria were exposed without illumination. Binding affinity to bacterial cells was found to represent an important parameter influencing phthalocyanine antibacterial activity that can be modified by total charge of peripheral substituents and by the presence of suitable functional groups inside them. Agglomeration of cells observed in suspensions treated with a higher concentration of certain cationic phthalocyanines (the strongest binders to bacterial membrane) affected cytometric measurements of total cell counts, thus without appropriate pretreatment of the sample before analysis this parameter seems not to be fully valid in the evaluation of phthalocyanine antibacterial activity. Cytometric measurement of cell membrane integrity appears to be a suitable and even more sensitive parameter than cultivation. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Footprint Characteristics of Cosmic-Ray Neutron Sensors for Soil Moisture Monitoring

    NASA Astrophysics Data System (ADS)

    Schrön, Martin; Köhli, Markus; Zreda, Marek; Dietrich, Peter; Zacharias, Steffen

    2015-04-01

    Cosmic-ray neutron sensing is a unique and an increasingly accepted method to monitor the effective soil water content at the field scale. The technology is famous for its low maintenance, non-invasiveness, continuous measurement, and most importantly, for its large footprint. Being more representative than point data and finer resolved than remote-sensing products, cosmic-ray neutron derived soil moisture products provide unrivaled advantage for mesoscale hydrologic and land surface models. The method takes advantage of neutrons induced by cosmic radiation which are extraordinarily sensitive to hydrogen and behave like a hot gas. Information about nearby water sources are quickly mixed in a domain of tens of hectares in air. Since experimental determination of the actual spatial extent is hardly possible, scientists have applied numerical models to address the footprint characteristics. We have revisited previous neutron transport simulations and present a modified conceptual design and refined physical assumptions. Our revised study reveals new insights into probing distance and water sensitivity of detected neutrons under various environmental conditions. These results sharpen the range of interpretation concerning the spatial extent of integral soil moisture products derived from cosmic-ray neutron counts. Our findings will have important impact on calibration strategies, on scales for data assimilation and on the interpolation of soil moisture data derived from mobile cosmic-ray neutron surveys.

  15. Effects of Hydrated Potato Starch on the Quality of Low-fat Ttoekgalbi (Korean Traditional Patty) Packaged in Modified Atmosphere Conditions during Storage.

    PubMed

    Muhlisin, S M Kang; Choi, W H; Lee, K T; Cheong, S H; Lee, S K

    2012-05-01

    This study was carried out to investigate the effects of hydrated potato starch on the quality of low-fat ttoekgalbi (Korean traditional patty) packaged in modified atmosphere conditions during storage. The ttoekgalbi was prepared from 53.2% lean beef, 13.9% lean pork, 9.3% pork fat, and 23.6% other ingredients. Two low-fat ttoekgalbi treatments were prepared by substituting pork fat with hydrated potato starch; either by 50% fat replacement (50% FR) or 100% fat replacement (100% FR). Both 50% and 100% FR increased the moisture, crude protein, and decreased fat content, cooking loss, and hardness. For MAP studies, 200 g of ttoekgalbi were placed on the tray and filled with gas composed of 70% O2: 30% CO2 (70% O2-MAP) and 30% CO2: 70% N2 (70% N2-MAP), and were stored at 5°C for 12 d. During the storage time, both 50% and 100% FR showed higher protein deterioration, while no differences were found in CIE a*, CIE L*, lipid oxidation, and bacterial counts in comparison to control. The ttoekgalbi with 70% O2-MAP was more red, lighter in color, and showed higher TBARS values compared with 70% N2-MAP. The meat with 70% N2-MAP showed lower aerobic bacterial counts in control than those with 70% O2-MAP. The lower anaerobic bacterial counts were observed only in 50% FR and 100% FR packed with 70% N2-MAP in comparison with 70% O2-MAP. In conclusion, the fat replacement with hydrated potato starch showed no negative effects on the quality of low fat ttoekgalbi during storage and 70% N2-MAP was better than 70% O2-MAP for low-fat ttoekgalbi packaging.

  16. Changes in bone marrow morphology in adults receiving romiplostim for the treatment of thrombocytopenia associated with primary immune thrombocytopenia.

    PubMed

    Janssens, Ann; Rodeghiero, Francesco; Anderson, David; Chong, Beng H; Boda, Zoltán; Pabinger, Ingrid; Červinek, Libor; Terrell, Deirdra R; Wang, Xuena; Franklin, Janet

    2016-06-01

    The effects of romiplostim on bone marrow morphology were evaluated in adults with immune thrombocytopenia (ITP). Patients with platelet counts <50 × 10(9)/L, ≥1 prior ITP therapies, and no collagen at baseline received weekly subcutaneous romiplostim starting at 1 μg/kg, adjusted to maintain platelet counts between 50 and 200 × 10(9)/L. Biopsies were scheduled after 1, 2, or 3 years of romiplostim (cohorts 1, 2, and 3, respectively). Irrespective of scheduled time, biopsies were performed earlier if patients discontinued or failed to achieve/maintain a response to romiplostim. Reticulin (silver stain) and collagen (trichrome stain) were graded by two hematopathologists using the modified Bauermeister scale (0-4). Of 169 patients, 131 had evaluable biopsies; 9/131 (6.9 %) had increases of ≥2 grades on the modified Bauermeister scale (cohort 1: 0/34; cohort 2: 2/39; cohort 3: 7/58), including two with collagen. Three of the nine patients had follow-up biopsies, including one patient with collagen; changes were reversible after romiplostim discontinuation. Of the nine patients, one had neutropenia detected by laboratory test and two had adverse events of anemia, both non-serious and not treatment-related. By actual exposure (as some biopsies did not occur as scheduled), the number of patients with grade increases ≥2 were year 1: 3/41, year 2: 1/38, year 3: 5/52. Twenty-four patients sustained platelet counts ≥50 × 10(9)/L for ≥6 months with no ITP medications after discontinuing romiplostim, i.e., they entered clinical remission of their ITP. In conclusion, in patients with ITP receiving romiplostim, bone marrow changes were observed in a small proportion of patients.ClinicalTrials.gov identifier: NCT#00907478.

  17. High prevalence of diarrhoegenic intestinal parasite infections among non-ART HIV patients in Fitche Hospital, Ethiopia.

    PubMed

    Adamu, Haileeyesus; Wegayehu, Teklu; Petros, Beyene

    2013-01-01

    HIV infection has been modifying both the epidemiology and outcome of parasite infections. Hence, this study was undertaken to determine the prevalence of Cryptosporidium and other intestinal parasite infections among HIV positives with and without Antiretroviral Treatment(ART) and its association with CD4+ T-cell count. A cross-sectional study was conducted at Fitche hospital focusing on HIV positives who came to hospital for follow-ups. A total of 378 HIV positive persons with and without ART participated in the study. Data on socio-demographic factors and diarrhoea status were obtained by interviewing all 214 with ART and 164 without ART. Stool samples were collected from all patients and examined for intestinal parasites using direct, formol-ether and modified acid-fast staining techniques. The prevalence of intestinal parasite infections in this study was significantly higher among HIV positive persons not on ART. Specifically, the rate of infection with Cryptosporidium species, Blastocystis spp., Giardia lamblia, and Entamoeba histolytica/E. dispar were higher, particularly in those with CD4+ T-cell counts less than 200 cells/µL. Fifty seven percent of the study participants were on ART. Out of these 164/378 (43%) of the non-ART study participants were infected with at least one intestinal parasite species. Significant association was observed between lower CD4+ T-cell count (<200 cells/µL) and the prevalence of Cryptosporidium spp. and Blastocystis spp. The two parasites were significantly more prevalent in HIV positive non-ART patients. HIV infection increased the risk of having Cryptosporidium and other intestinal parasites and diarrhoea. Therefore, raising HIV positive's immune status and screening for intestinal parasites is important. This study showed that patients who are taking ART had a lower prevalence of diarrhoea causing parasites and Cryptosporidium suggesting that ART through improvement of immune status of the patients may have contributed to controlling diarrhoea-causing parasites in HIV positive patients.

  18. Roots Air Management System with Integrated Expander

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stretch, Dale; Wright, Brad; Fortini, Matt

    2016-07-06

    PEM fuel cells remain an emerging technology in the vehicle market with several cost and reliability challenges that must be overcome in order to increase market penetration and acceptance. The DOE has identified the lack of a cost effective, reliable, and efficient air supply system that meets the operational requirements of a pressurized PEM 80kW fuel cell as one of the major technological barriers that must be overcome. This project leveraged Roots positive displacement development advancements and demonstrated an efficient and low cost fuel cell air management system. Eaton built upon its P-Series Roots positive displacement design and shifted themore » peak efficiency making it ideal for use on an 80kW PEM stack. Advantages to this solution include: • Lower speed of the Roots device eliminates complex air bearings present on other systems. • Broad efficiency map of Roots based systems provides an overall higher drive cycle fuel economy. • Core Roots technology has been developed and validated for other transportation applications. Eaton modified their novel R340 Twin Vortices Series (TVS) Roots-type supercharger for this application. The TVS delivers more power and better fuel economy in a smaller package as compared to other supercharger technologies. By properly matching the helix angle with the rotor’s physical aspect ratio, the supercharger’s peak efficiency can be moved to the operating range where it is most beneficial for the application. The compressor was designed to meet the 90 g/s flow at a pressure ratio of 2.5, similar in design to the P-Series 340. A net shape plastic expander housing with integrated motor and compressor was developed to significantly reduce the cost of the system. This integrated design reduced part count by incorporating an overhung expander and motor rotors into the design such that only four bearings and two shafts were utilized.« less

  19. Event specific qualitative and quantitative polymerase chain reaction detection of genetically modified MON863 maize based on the 5'-transgene integration sequence.

    PubMed

    Yang, Litao; Xu, Songci; Pan, Aihu; Yin, Changsong; Zhang, Kewei; Wang, Zhenying; Zhou, Zhigang; Zhang, Dabing

    2005-11-30

    Because of the genetically modified organisms (GMOs) labeling policies issued in many countries and areas, polymerase chain reaction (PCR) methods were developed for the execution of GMO labeling policies, such as screening, gene specific, construct specific, and event specific PCR detection methods, which have become a mainstay of GMOs detection. The event specific PCR detection method is the primary trend in GMOs detection because of its high specificity based on the flanking sequence of the exogenous integrant. This genetically modified maize, MON863, contains a Cry3Bb1 coding sequence that produces a protein with enhanced insecticidal activity against the coleopteran pest, corn rootworm. In this study, the 5'-integration junction sequence between the host plant DNA and the integrated gene construct of the genetically modified maize MON863 was revealed by means of thermal asymmetric interlaced-PCR, and the specific PCR primers and TaqMan probe were designed based upon the revealed 5'-integration junction sequence; the conventional qualitative PCR and quantitative TaqMan real-time PCR detection methods employing these primers and probes were successfully developed. In conventional qualitative PCR assay, the limit of detection (LOD) was 0.1% for MON863 in 100 ng of maize genomic DNA for one reaction. In the quantitative TaqMan real-time PCR assay, the LOD and the limit of quantification were eight and 80 haploid genome copies, respectively. In addition, three mixed maize samples with known MON863 contents were detected using the established real-time PCR systems, and the ideal results indicated that the established event specific real-time PCR detection systems were reliable, sensitive, and accurate.

  20. To What Extent is Primate Second Molar Enamel Occlusal Morphology Shaped by the Enamel-Dentine Junction?

    PubMed Central

    Gilissen, Emmanuel; Thiery, Ghislain

    2015-01-01

    The form of two hard tissues of the mammalian tooth, dentine and enamel, is the result of a combination of the phylogenetic inheritance of dental traits and the adaptive selection of these traits during evolution. Recent decades have been significant in unveiling developmental processes controlling tooth morphogenesis, dental variation and the origination of dental novelties. The enamel-dentine junction constitutes a precursor for the morphology of the outer enamel surface through growth of the enamel cap which may go along with the addition of original features. The relative contribution of these two tooth components to morphological variation and their respective response to natural selection is a major issue in paleoanthropology. This study will determine how much enamel morphology relies on the form of the enamel-dentine junction. The outer occlusal enamel surface and the enamel-dentine junction surface of 76 primate second upper molars are represented by polygonal meshes and investigated using tridimensional topometrical analysis. Quantitative criteria (elevation, inclination, orientation, curvature and occlusal patch count) are introduced to show that the enamel-dentine junction significantly constrains the topographical properties of the outer enamel surface. Our results show a significant correlation for elevation, orientation, inclination, curvature and occlusal complexity between the outer enamel surface and the enamel dentine junction for all studied primate taxa with the exception of four modern humans for curvature (p<0.05). Moreover, we show that, for all selected topometrical parameters apart from occlusal patch count, the recorded correlations significantly decrease along with enamel thickening in our sample. While preserving tooth integrity by providing resistance to wear and fractures, the variation of enamel thickness may modify the curvature present at the occlusal enamel surface in relation to enamel-dentine junction, potentially modifying dental functionalities such as blunt versus sharp dental tools. In terms of natural selection, there is a balance between increasing tooth resistance and maintaining efficient dental tools. In this sense the enamel cap acts as a functional buffer for the molar occlusal pattern. In primates, results suggest a primary emergence of dental novelties on the enamel-dentine junction and a secondary transposition of these novelties with no or minor modifications of dental functionalities by the enamel cap. Whereas enamel crenations have been reported by previous studies, our analysis do not support the presence of enamel tubercles without dentine relief nuclei. As is, the enamel cap is, at most, a secondary source of morphological novelty. PMID:26406597

  1. Volatile metabolite production of spoilage micro-organisms on a mixed-lettuce agar during storage at 7 degrees C in air and low oxygen atmosphere.

    PubMed

    Ragaert, P; Devlieghere, F; Devuyst, E; Dewulf, J; Van Langenhove, H; Debevere, J

    2006-11-01

    This paper describes the volatile metabolite production of spoilage bacteria (Pantoea agglomerans and Rahnella aquatilis) and spoilage yeasts (Pichia fermentans and Cryptococcus laurentii), previously isolated from mixed lettuce, on a simulation medium of shredded mixed lettuce (mixed-lettuce agar) both under air conditions and modified atmosphere (MA)-conditions at 7 degrees C. These latter conditions simulated the equilibrium modified atmosphere packaging, which is used to extend the shelf-life of shredded mixed lettuce. Besides volatile metabolites, organic acid metabolites and consumption of sugars were measured. Microbiological growth on the mixed-lettuce agar resulted in metabolite production and consumption of sugars. Bacteria and yeasts produced a range of volatile organic compounds both under air conditions and MA-conditions: ethanol, ethyl acetate, 2-methyl-1-propanol, 2-methyl-1-butanol, 3-methyl-1-butanol, 2,3-butanedione, 3-methyl-1-pentanol, 1-butanol and 1-hexanol. Under MA-conditions, 2-methyl-1-butanol, 3-methyl-1-butanol and ethanol were the first compounds that were detected in the headspace as being produced by the inoculated micro-organisms. In the case of the yeast P. fermentans, production of these compounds was detected from a count of 5.0+/-0.1 log cfu/cm(2) with a fast increase when exceeding 6.0-6.5 log cfu/cm(2). Unlike P. fermentans, the yeast C. laurentii showed a slow metabolism under MA-conditions, compared to air conditions. In the case of the bacteria, production of 2-methyl-1-butanol and 3-methyl-1-butanol was detected starting from a count of 6.7+/-0.1 log cfu/cm(2) in the case of R. aquatilis and from a count of 7.1+/-0.4 log cfu/cm(2) in the case of P. agglomerans with a fast increase when exceeding 8 log cfu/cm(2). No production of ethanol by the bacteria under MA-conditions was detected in contradiction to air conditions. It could be concluded that, if these counts are reached on the cut surfaces of shredded mixed lettuce which are simulated by the mixed-lettuce agar, sensorial quality of shredded mixed lettuce could be influenced by the microbiological production of metabolites.

  2. The Uses and Dependency Model of Mass Communication.

    ERIC Educational Resources Information Center

    Rubin, Alan M.; Windahl, Sven

    1986-01-01

    Responds to criticism of the uses and gratification model by proposing a modified model integrating the dependency perspective. Suggests that this integrated model broadens the heuristic application of the earlier model. (MS)

  3. DMRfinder: efficiently identifying differentially methylated regions from MethylC-seq data.

    PubMed

    Gaspar, John M; Hart, Ronald P

    2017-11-29

    DNA methylation is an epigenetic modification that is studied at a single-base resolution with bisulfite treatment followed by high-throughput sequencing. After alignment of the sequence reads to a reference genome, methylation counts are analyzed to determine genomic regions that are differentially methylated between two or more biological conditions. Even though a variety of software packages is available for different aspects of the bioinformatics analysis, they often produce results that are biased or require excessive computational requirements. DMRfinder is a novel computational pipeline that identifies differentially methylated regions efficiently. Following alignment, DMRfinder extracts methylation counts and performs a modified single-linkage clustering of methylation sites into genomic regions. It then compares methylation levels using beta-binomial hierarchical modeling and Wald tests. Among its innovative attributes are the analyses of novel methylation sites and methylation linkage, as well as the simultaneous statistical analysis of multiple sample groups. To demonstrate its efficiency, DMRfinder is benchmarked against other computational approaches using a large published dataset. Contrasting two replicates of the same sample yielded minimal genomic regions with DMRfinder, whereas two alternative software packages reported a substantial number of false positives. Further analyses of biological samples revealed fundamental differences between DMRfinder and another software package, despite the fact that they utilize the same underlying statistical basis. For each step, DMRfinder completed the analysis in a fraction of the time required by other software. Among the computational approaches for identifying differentially methylated regions from high-throughput bisulfite sequencing datasets, DMRfinder is the first that integrates all the post-alignment steps in a single package. Compared to other software, DMRfinder is extremely efficient and unbiased in this process. DMRfinder is free and open-source software, available on GitHub ( github.com/jsh58/DMRfinder ); it is written in Python and R, and is supported on Linux.

  4. Insect Biometrics: Optoacoustic Signal Processing and Its Applications to Remote Monitoring of McPhail Type Traps.

    PubMed

    Potamitis, Ilyas; Rigakis, Iraklis; Fysarakis, Konstantinos

    2015-01-01

    Monitoring traps are important components of integrated pest management applied against important fruit fly pests, including Bactrocera oleae (Gmelin) and Ceratitis capitata (Widemann), Diptera of the Tephritidae family, which effect a crop-loss/per year calculated in billions of euros worldwide. Pests can be controlled with ground pesticide sprays, the efficiency of which depends on knowing the time, location and extent of infestations as early as possible. Trap inspection is currently carried out manually, using the McPhail trap, and the mass spraying is decided based on a decision protocol. We introduce the term 'insect biometrics' in the context of entomology as a measure of a characteristic of the insect (in our case, the spectrum of its wingbeat) that allows us to identify its species and make devices to help face old enemies with modern means. We modify a McPhail type trap into becoming electronic by installing an array of photoreceptors coupled to an infrared emitter, guarding the entrance of the trap. The beating wings of insects flying in the trap intercept the light and the light fluctuation is turned to a recording. Custom-made electronics are developed that are placed as an external add-on kit, without altering the internal space of the trap. Counts from the trap are transmitted using a mobile communication network. This trap introduces a new automated remote-monitoring method different to audio and vision-based systems. We evaluate our trap in large number of insects in the laboratory by enclosing the electronic trap in insectary cages. Our experiments assess the potential of delivering reliable data that can be used to initialize reliably the spraying process at large scales but to also monitor the impact of the spraying process as it eliminates the time-lag between acquiring and delivering insect counts to a central agency.

  5. Modeling complexity in pathologist workload measurement: the Automatable Activity-Based Approach to Complexity Unit Scoring (AABACUS).

    PubMed

    Cheung, Carol C; Torlakovic, Emina E; Chow, Hung; Snover, Dale C; Asa, Sylvia L

    2015-03-01

    Pathologists provide diagnoses relevant to the disease state of the patient and identify specific tissue characteristics relevant to response to therapy and prognosis. As personalized medicine evolves, there is a trend for increased demand of tissue-derived parameters. Pathologists perform increasingly complex analyses on the same 'cases'. Traditional methods of workload assessment and reimbursement, based on number of cases sometimes with a modifier (eg, the relative value unit (RVU) system used in the United States), often grossly underestimate the amount of work needed for complex cases and may overvalue simple, small biopsy cases. We describe a new approach to pathologist workload measurement that aligns with this new practice paradigm. Our multisite institution with geographically diverse partner institutions has developed the Automatable Activity-Based Approach to Complexity Unit Scoring (AABACUS) model that captures pathologists' clinical activities from parameters documented in departmental laboratory information systems (LISs). The model's algorithm includes: 'capture', 'export', 'identify', 'count', 'score', 'attribute', 'filter', and 'assess filtered results'. Captured data include specimen acquisition, handling, analysis, and reporting activities. Activities were counted and complexity units (CUs) generated using a complexity factor for each activity. CUs were compared between institutions, practice groups, and practice types and evaluated over a 5-year period (2008-2012). The annual load of a clinical service pathologist, irrespective of subspecialty, was ∼40,000 CUs using relative benchmarking. The model detected changing practice patterns and was appropriate for monitoring clinical workload for anatomical pathology, neuropathology, and hematopathology in academic and community settings, and encompassing subspecialty and generalist practices. AABACUS is objective, can be integrated with an LIS and automated, is reproducible, backwards compatible, and future adaptable. It can be applied as a robust decision support tool for the assessment of overall and targeted staffing needs as well as utilization analyses for resource allocation.

  6. Insect Biometrics: Optoacoustic Signal Processing and Its Applications to Remote Monitoring of McPhail Type Traps

    PubMed Central

    Potamitis, Ilyas; Rigakis, Iraklis; Fysarakis, Konstantinos

    2015-01-01

    Monitoring traps are important components of integrated pest management applied against important fruit fly pests, including Bactrocera oleae (Gmelin) and Ceratitis capitata (Widemann), Diptera of the Tephritidae family, which effect a crop-loss/per year calculated in billions of euros worldwide. Pests can be controlled with ground pesticide sprays, the efficiency of which depends on knowing the time, location and extent of infestations as early as possible. Trap inspection is currently carried out manually, using the McPhail trap, and the mass spraying is decided based on a decision protocol. We introduce the term ‘insect biometrics’ in the context of entomology as a measure of a characteristic of the insect (in our case, the spectrum of its wingbeat) that allows us to identify its species and make devices to help face old enemies with modern means. We modify a McPhail type trap into becoming electronic by installing an array of photoreceptors coupled to an infrared emitter, guarding the entrance of the trap. The beating wings of insects flying in the trap intercept the light and the light fluctuation is turned to a recording. Custom-made electronics are developed that are placed as an external add-on kit, without altering the internal space of the trap. Counts from the trap are transmitted using a mobile communication network. This trap introduces a new automated remote-monitoring method different to audio and vision-based systems. We evaluate our trap in large number of insects in the laboratory by enclosing the electronic trap in insectary cages. Our experiments assess the potential of delivering reliable data that can be used to initialize reliably the spraying process at large scales but to also monitor the impact of the spraying process as it eliminates the time-lag between acquiring and delivering insect counts to a central agency. PMID:26544845

  7. A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.

    PubMed

    Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi

    2010-04-01

    The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.

  8. On the frequency response of a Wenglor particle-counting system for aeolian transport measurements

    NASA Astrophysics Data System (ADS)

    Bauer, Bernard O.; Davidson-Arnott, Robin G. D.; Hilton, Michael J.; Fraser, Douglas

    2018-06-01

    A commonly deployed particle-counting system for aeolian saltation flux, consisting of a Wenglor fork sensor and an Onset Hobo Pulse Input Adapter linked to an Onset Hobo Energy Logger Pro data logger, was tested for frequency response. The Wenglor fork sensor is an optical gate device that has very fast switching capacity that can accommodate the time of flight of saltating sand particles through the sensing volume with the exception of very fine sand or silt and very quickly moving particles. The Pulse Input Adapter, in contrast, imposes limitations on the frequency response of the system. The manufacturer of the pulse adapter specifies an upper limit of 120 Hz, although bench tests with an electronic pulse generator indicate that the frequency response of the Pulse Input Adapter, in isolation, is excellent up to 3000 Hz, with only small error (less than 1.6%) due to under-counting during data transfer intervals. A mechanical test of the integrated system (fork sensor, pulse input adapter, and data logger) demonstrates excellent performance up to about 700 Hz (less than 2% error), but significant under-counting above 1000 Hz for unknown reasons. This specific particle-counting system therefore has a frequency response that is well suited for investigation of the dynamics of aeolian saltation as typically encountered in most field conditions on coastal beaches with the exception of extreme wind events and very small particle sizes.

  9. Single-photon counting multicolor multiphoton fluorescence microscope.

    PubMed

    Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C

    2005-01-01

    We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

  10. 10 CFR 429.20 - Residential clothes washers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...). For standard-size residential clothes washers, a water factor (WF) in gallons per cycle per cubic feet... integrated modified energy factor (IMEF) in cu ft/kWh/cycle, the integrated water factor (IWF) in gal/cycle... randomly selected and tested to ensure that— (i) Any represented value of the water factor, integrated...

  11. 10 CFR 429.20 - Residential clothes washers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...). For standard-size residential clothes washers, a water factor (WF) in gallons per cycle per cubic feet... integrated modified energy factor (IMEF) in cu ft/kWh/cycle, the integrated water factor (IWF) in gal/cycle... randomly selected and tested to ensure that— (i) Any represented value of the water factor, integrated...

  12. An Integrated Scale for Measuring an Organizational Learning System

    ERIC Educational Resources Information Center

    Jyothibabu, C.; Farooq, Ayesha; Pradhan, Bibhuti Bhusan

    2010-01-01

    Purpose: The purpose of this paper is to develop an integrated measurement scale for an organizational learning system by capturing the learning enablers, learning results and performance outcome in an organization. Design/methodology/approach: A new measurement scale was developed by integrating and modifying two existing scales, identified…

  13. Developing a Collegial Approach to Integrated Planning at a Small College: Communication, Understanding, and Cooperation.

    ERIC Educational Resources Information Center

    Farmer, D. W.

    1983-01-01

    An effective collegial and relatively noncompetitive approach to integrated planning developed at King's College is discussed. The development of a structured system of intensive oral communication; an organizational design integrating planning, budgeting, marketing, and evaluation, and a modified matrix management system are described. (MLW)

  14. SGR 1822-1606 (Swift J1822.3-1606): X-ray spectrum and refined spin period from Swift XRT analysis

    NASA Astrophysics Data System (ADS)

    Esposito, P.; Rea, N.; Israel, G. L.

    2011-07-01

    We have analysed 1.6 ks s of Photon Counting (PC) XRT data of the new SGR/magnetar candidate Swift J1822.3-1606 (Cummings et al. GCN #12159), including the first 0.6 ks on which Pagani et al. reported in GCN #12163. We found that the source spectrum is well described by a power-law plus blackbody model, modified for the interstellar absorption (reduced chi-squared = 1.04 for 97 degrees of freedom).

  15. Robust Control for the Mercury Laser Altimeter

    NASA Technical Reports Server (NTRS)

    Rosenberg, Jacob S.

    2006-01-01

    Mercury Laser Altimeter Science Algorithms is a software system for controlling the laser altimeter aboard the Messenger spacecraft, which is to enter into orbit about Mercury in 2011. The software will control the altimeter by dynamically modifying hardware inputs for gain, threshold, channel-disable flags, range-window start location, and range-window width, by using ranging information provided by the spacecraft and noise counts from instrument hardware. In addition, because of severe bandwidth restrictions, the software also selects returns for downlink.

  16. The present state of research and exploitation of biotech (GM) crops in horticulture: results of research on plum cv. 'HoneySweet' resistant to plum pox virus (Sharka) and the deregulation of this cultivar in the CR & Europe

    USDA-ARS?s Scientific Manuscript database

    Gentically modified (GM) crops were grown world-wide on 160 million ha in 2011. Only 114.57 ha of GM crops were grown in Europe, of that, 114.90 ha were Bt maize and 17 ha were potato for industrial starch production. Commercialization of Biotech crops started in 1995. Currently, developing count...

  17. 78 FR 51812 - Urbanized Area Formula Grants; Passenger Ferry Grant Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... Sources of Match D. Proposal Submission Process E. Proposal Information F. Proposal Content G. Evaluation... as the market value of in-kind contributions integral to the project may be counted as a contribution... making a resubmission for any reason, include all original attachments regardless of which attachments...

  18. Network origin-destination demand estimation using limited link traffic counts : strategic deployment of vehicle detectors through an integrated corridor management framework.

    DOT National Transportation Integrated Search

    2009-10-15

    In typical road traffic corridors, freeway systems are generally well-equipped with traffic surveillance systems such as vehicle detector (VD) and/or closed circuit television (CCTV) systems in order to gather timely traffic information for traffic c...

  19. The Man Who Counted: A Collection of Integrated Adventures

    ERIC Educational Resources Information Center

    Wilder, Sandra; Lang, Annette; Monegan, Max

    2015-01-01

    Issues of disconnect and isolation from other disciplines seem to plague numerous subjects taught in high schools today. Although they share common roots, mathematics, natural sciences and humanities appeared to have developed rich, but separated curricula with only occasionally emphasized and seemingly weak connections between their respective…

  20. Dynamic Properties of Electronic Trapping Centers at the Si-SiO2 Interface.

    DTIC Science & Technology

    1983-05-01

    Variation of i,. %.rhich is the sum of the majorty and minoritl) the integration is over the semiconductor bandgap. The for- carrier emision and capture...majority carriers, and the dashed line is for majority,- counted for, will yield erroneous interface-state distribu- carrier emision onl) tions

  1. Towards Applied Integrationism--Integrating Autism in Teaching and Coaching Sessions

    ERIC Educational Resources Information Center

    Nielsen, Charlotte Marie Bisgaard

    2011-01-01

    At present, Denmark counts numerous cases of youngsters with Aspergers syndrome and the implementation of separate project classrooms for Asperger-students has proved beneficial (EVA-report January 2010). Today, Asperger-students at project schools have the opportunity to receive an education whereas before they often ended up as psychiatric…

  2. Effects of the oral administration of nonpolar extract from Ardisia squamulosa Presl (Myrsinaceae) leaves on spermatogenesis in rats.

    PubMed

    Raga, Dennis D; Pocsidio, Glorina N; Herrera, Annabelle A

    2011-10-01

    Several Ardisia species have been found to possess numerous bioactivities but their reproductive toxicity has been poorly explored. In the present study, the effects of the leaf hexane extract of Philippine indigenous Ardisia squamulosa on epididymal sperm count, %viability and %aberration of sperms and weights of seminal vesicle, cauda epididymis, and testes in addition to the weights of liver, kidney, and body were evaluated. The extracts at daily dose levels of 1, 10, and 100 mg/Kg BW in 10% polysorbate-80 in corn oil were administered by gavage for 8 successive days to 8-10 weeks old male SD rats and sacrificed after 9 days. Daily body weights and final organ weights were measured. Sperm from the cauda epididymis was extracted and measured according standard sperm parameters (sperm count, morphology, viability and membrane integrity). Significant findings were the decline of left epididymal sperm count to testis weight ratio and increase in %sperm morphological aberration from both cauda epididymis obtained with the 10 mg/Kg BW dose. The hexane extract from Ardisia squamulosa had significant effect on sperm count but with negligible effect on sperm morphology and viability.

  3. Assessment of cell concentration and viability of isolated hepatocytes using flow cytometry.

    PubMed

    Wigg, Alan J; Phillips, John W; Wheatland, Loretta; Berry, Michael N

    2003-06-01

    The assessment of cell concentration and viability of freshly isolated hepatocyte preparations has been traditionally performed using manual counting with a Neubauer counting chamber and staining for trypan blue exclusion. Despite the simple and rapid nature of this assessment, concerns about the accuracy of these methods exist. Simple flow cytometry techniques which determine cell concentration and viability are available yet surprisingly have not been extensively used or validated with isolated hepatocyte preparations. We therefore investigated the use of flow cytometry using TRUCOUNT Tubes and propidium iodide staining to measure cell concentration and viability of isolated rat hepatocytes in suspension. Analysis using TRUCOUNT Tubes provided more accurate and reproducible measurement of cell concentration than manual cell counting. Hepatocyte viability, assessed using propidium iodide, correlated more closely than did trypan blue exclusion with all indicators of hepatocyte integrity and function measured (lactate dehydrogenase leakage, cytochrome p450 content, cellular ATP concentration, ammonia and lactate removal, urea and albumin synthesis). We conclude that flow cytometry techniques can be used to measure cell concentration and viability of isolated hepatocyte preparations. The techniques are simple, rapid, and more accurate than manual cell counting and trypan blue staining and the results are not affected by protein-containing media.

  4. An Early Mathematical Patterning Assessment: identifying young Australian Indigenous children's patterning skills

    NASA Astrophysics Data System (ADS)

    Papic, Marina

    2015-12-01

    This paper presents an Early Mathematical Patterning Assessment (EMPA) tool that provides early childhood educators with a valuable opportunity to identify young children's mathematical thinking and patterning skills through a series of hands-on and drawing tasks. EMPA was administered through one-to-one assessment interviews to children aged 4 to 5 years in the year prior to formal school. Two hundred and seventeen assessments indicated that the young low socioeconomic and predominantly Australian Indigenous children in the study group had varied patterning and counting skills. Three percent of the study group was able to consistently copy and draw an ABABAB pattern made with coloured blocks. Fifty percent could count to six by ones and count out six items with 4 % of the total group able to identify six items presented in regular formations without counting. The integration of patterning into early mathematics learning is critical to the abstraction of mathematical ideas and relationships and to the development of mathematical reasoning in young children. By using the insights into the children's thinking that the EMPA tool provides, early childhood educators can better inform mathematics teaching and learning and so help close the persistent gap in numeracy between Indigenous and non-Indigenous children.

  5. A polychromatic adaption of the Beer-Lambert model for spectral decomposition

    NASA Astrophysics Data System (ADS)

    Sellerer, Thorsten; Ehn, Sebastian; Mechlem, Korbinian; Pfeiffer, Franz; Herzen, Julia; Noël, Peter B.

    2017-03-01

    We present a semi-empirical forward-model for spectral photon-counting CT which is fully compatible with state-of-the-art maximum-likelihood estimators (MLE) for basis material line integrals. The model relies on a minimum calibration effort to make the method applicable in routine clinical set-ups with the need for periodic re-calibration. In this work we present an experimental verifcation of our proposed method. The proposed method uses an adapted Beer-Lambert model, describing the energy dependent attenuation of a polychromatic x-ray spectrum using additional exponential terms. In an experimental dual-energy photon-counting CT setup based on a CdTe detector, the model demonstrates an accurate prediction of the registered counts for an attenuated polychromatic spectrum. Thereby deviations between model and measurement data lie within the Poisson statistical limit of the performed acquisitions, providing an effectively unbiased forward-model. The experimental data also shows that the model is capable of handling possible spectral distortions introduced by the photon-counting detector and CdTe sensor. The simplicity and high accuracy of the proposed model provides a viable forward-model for MLE-based spectral decomposition methods without the need of costly and time-consuming characterization of the system response.

  6. Estimating demographic parameters using a combination of known-fate and open N-mixture models

    USGS Publications Warehouse

    Schmidt, Joshua H.; Johnson, Devin S.; Lindberg, Mark S.; Adams, Layne G.

    2015-01-01

    Accurate estimates of demographic parameters are required to infer appropriate ecological relationships and inform management actions. Known-fate data from marked individuals are commonly used to estimate survival rates, whereas N-mixture models use count data from unmarked individuals to estimate multiple demographic parameters. However, a joint approach combining the strengths of both analytical tools has not been developed. Here we develop an integrated model combining known-fate and open N-mixture models, allowing the estimation of detection probability, recruitment, and the joint estimation of survival. We demonstrate our approach through both simulations and an applied example using four years of known-fate and pack count data for wolves (Canis lupus). Simulation results indicated that the integrated model reliably recovered parameters with no evidence of bias, and survival estimates were more precise under the joint model. Results from the applied example indicated that the marked sample of wolves was biased toward individuals with higher apparent survival rates than the unmarked pack mates, suggesting that joint estimates may be more representative of the overall population. Our integrated model is a practical approach for reducing bias while increasing precision and the amount of information gained from mark–resight data sets. We provide implementations in both the BUGS language and an R package.

  7. Estimating demographic parameters using a combination of known-fate and open N-mixture models.

    PubMed

    Schmidt, Joshua H; Johnson, Devin S; Lindberg, Mark S; Adams, Layne G

    2015-10-01

    Accurate estimates of demographic parameters are required to infer appropriate ecological relationships and inform management actions. Known-fate data from marked individuals are commonly used to estimate survival rates, whereas N-mixture models use count data from unmarked individuals to estimate multiple demographic parameters. However, a joint approach combining the strengths of both analytical tools has not been developed. Here we develop an integrated model combining known-fate and open N-mixture models, allowing the estimation of detection probability, recruitment, and the joint estimation of survival. We demonstrate our approach through both simulations and an applied example using four years of known-fate and pack count data for wolves (Canis lupus). Simulation results indicated that the integrated model reliably recovered parameters with no evidence of bias, and survival estimates were more precise under the joint model. Results from the applied example indicated that the marked sample of wolves was biased toward individuals with higher apparent survival rates than the unmarked pack mates, suggesting that joint estimates may be more representative of the overall population. Our integrated model is a practical approach for reducing bias while increasing precision and the amount of information gained from mark-resight data sets. We provide implementations in both the BUGS language and an R package.

  8. Cytotoxicity of modified nonequilibrium plasma with chlorhexidine digluconate on primary cultured human gingival fibroblasts.

    PubMed

    Chen, Hui; Shi, Qi; Qing, Ying; Yao, Yi-chen; Cao, Ying-guang

    2016-02-01

    The aim of this study was to investigate the cytotoxicity of modified nonequilibrium plasma with chlorhexidine digluconate (CHX) on human gingival fibroblasts (HGFs), and to evaluate the biosecurity of modified nonequilibrium plasma with 2% CHX as a new method of root canal treatment. Tissue samples taken from human gingiva were primarily cultured and passaged. Cells from passages 3-7 were used. HGFs were treated by modified nonequilibrium plasma with 2% CHX for 0 min (control group), 30 s, 1 min, 1.5 min, 3 min, 5 min, and 10 min, respectively, and then they were incubated for 0, 24, and 48 h. After that, cell counting kit-8 (CCK-8) assay was applied to analyze the cytotoxicity of modified nonequilibrium plasma with 2% CHX on HGFs. There was no significant difference between the 0 h group treated with the modified nonequilibrium plasma for 1 min and the control group (P>0.05). However, there were significant differences between all the other treated groups and the control group (P<0.05). When treated for 1.5 min or shorter, the cell viability was obviously increased; while treated for 3 min or longer, it was obviously reduced. Moreover, when successively cultured for 0, 24, and 48 h, cell viability was decreased at first and then increased in the 3-min-treated and 5-min-treated groups. The modified nonequilibrium plasma with 2% CHX was of no influence on cell viability in 1.5 min treatment, and it could be safely used on root canal treatment.

  9. Selecting the right statistical model for analysis of insect count data by using information theoretic measures.

    PubMed

    Sileshi, G

    2006-10-01

    Researchers and regulatory agencies often make statistical inferences from insect count data using modelling approaches that assume homogeneous variance. Such models do not allow for formal appraisal of variability which in its different forms is the subject of interest in ecology. Therefore, the objectives of this paper were to (i) compare models suitable for handling variance heterogeneity and (ii) select optimal models to ensure valid statistical inferences from insect count data. The log-normal, standard Poisson, Poisson corrected for overdispersion, zero-inflated Poisson, the negative binomial distribution and zero-inflated negative binomial models were compared using six count datasets on foliage-dwelling insects and five families of soil-dwelling insects. Akaike's and Schwarz Bayesian information criteria were used for comparing the various models. Over 50% of the counts were zeros even in locally abundant species such as Ootheca bennigseni Weise, Mesoplatys ochroptera Stål and Diaecoderus spp. The Poisson model after correction for overdispersion and the standard negative binomial distribution model provided better description of the probability distribution of seven out of the 11 insects than the log-normal, standard Poisson, zero-inflated Poisson or zero-inflated negative binomial models. It is concluded that excess zeros and variance heterogeneity are common data phenomena in insect counts. If not properly modelled, these properties can invalidate the normal distribution assumptions resulting in biased estimation of ecological effects and jeopardizing the integrity of the scientific inferences. Therefore, it is recommended that statistical models appropriate for handling these data properties be selected using objective criteria to ensure efficient statistical inference.

  10. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    NASA Astrophysics Data System (ADS)

    Lockhart, M.; Henzlova, D.; Croft, S.; Cutler, T.; Favalli, A.; McGahee, Ch.; Parker, R.

    2018-01-01

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli(DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. The current paper discusses and presents the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. In order to assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. The DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

  11. A comparison of two multi-variable integrator windup protection schemes

    NASA Technical Reports Server (NTRS)

    Mattern, Duane

    1993-01-01

    Two methods are examined for limit and integrator wind-up protection for multi-input, multi-output linear controllers subject to actuator constraints. The methods begin with an existing linear controller that satisfies the specifications for the nominal, small perturbation, linear model of the plant. The controllers are formulated to include an additional contribution to the state derivative calculations. The first method to be examined is the multi-variable version of the single-input, single-output, high gain, Conventional Anti-Windup (CAW) scheme. Except for the actuator limits, the CAW scheme is linear. The second scheme to be examined, denoted the Modified Anti-Windup (MAW) scheme, uses a scalar to modify the magnitude of the controller output vector while maintaining the vector direction. The calculation of the scalar modifier is a nonlinear function of the controller outputs and the actuator limits. In both cases the constrained actuator is tracked. These two integrator windup protection methods are demonstrated on a turbofan engine control system with five measurements, four control variables, and four actuators. The closed-loop responses of the two schemes are compared and contrasted during limit operation. The issue of maintaining the direction of the controller output vector using the Modified Anti-Windup scheme is discussed and the advantages and disadvantages of both of the IWP methods are presented.

  12. Preparation of melt-spun antimicrobially modified LDH/polyolefin nanocomposite fibers.

    PubMed

    Kutlu, Burak; Schröttner, Percy; Leuteritz, Andreas; Boldt, Regine; Jacobs, Enno; Heinrich, Gert

    2014-08-01

    Layered double hydroxide (LDH) was synthesized and organically modified with camphorsulfonic acid (CSA) and ciprofloxacin. The thermal stability of CSA was improved remarkably under LDH shielding. A minimal inhibitory concentration of free CSA against tested bacteria was determined in order to define the essential quantity in LDH modification. The modified LDHs were melt-compounded with high density polyethylene and the prepared nanocomposites were further melt-spun using a piston-type spinning device. The melt-spun fibers were tested for their antimicrobial activity against Escherichia coli, Proteus vulgaris, Pseudomonas aeruginosa, Enterobacter cloacae, Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus pyogenes. CSA integrated fibers show susceptibility against Gram-positive bacteria and ciprofloxacin integrated fibers showed activity against both Gram-positive and Gram-negative bacteria. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Analysis of 3D poroelastodynamics using BEM based on modified time-step scheme

    NASA Astrophysics Data System (ADS)

    Igumnov, L. A.; Petrov, A. N.; Vorobtsov, I. V.

    2017-10-01

    The development of 3d boundary elements modeling of dynamic partially saturated poroelastic media using a stepping scheme is presented in this paper. Boundary Element Method (BEM) in Laplace domain and the time-stepping scheme for numerical inversion of the Laplace transform are used to solve the boundary value problem. The modified stepping scheme with a varied integration step for quadrature coefficients calculation using the symmetry of the integrand function and integral formulas of Strongly Oscillating Functions was applied. The problem with force acting on a poroelastic prismatic console end was solved using the developed method. A comparison of the results obtained by the traditional stepping scheme with the solutions obtained by this modified scheme shows that the computational efficiency is better with usage of combined formulas.

  14. Highly integrated digital electronic control: Digital flight control, aircraft model identification, and adaptive engine control

    NASA Technical Reports Server (NTRS)

    Baer-Riedhart, Jennifer L.; Landy, Robert J.

    1987-01-01

    The highly integrated digital electronic control (HIDEC) program at NASA Ames Research Center, Dryden Flight Research Facility is a multiphase flight research program to quantify the benefits of promising integrated control systems. McDonnell Aircraft Company is the prime contractor, with United Technologies Pratt and Whitney Aircraft, and Lear Siegler Incorporated as major subcontractors. The NASA F-15A testbed aircraft was modified by the HIDEC program by installing a digital electronic flight control system (DEFCS) and replacing the standard F100 (Arab 3) engines with F100 engine model derivative (EMD) engines equipped with digital electronic engine controls (DEEC), and integrating the DEEC's and DEFCS. The modified aircraft provides the capability for testing many integrated control modes involving the flight controls, engine controls, and inlet controls. This paper focuses on the first two phases of the HIDEC program, which are the digital flight control system/aircraft model identification (DEFCS/AMI) phase and the adaptive engine control system (ADECS) phase.

  15. Image Reconstruction for a Partially Collimated Whole Body PET Scanner

    PubMed Central

    Alessio, Adam M.; Schmitz, Ruth E.; MacDonald, Lawrence R.; Wollenweber, Scott D.; Stearns, Charles W.; Ross, Steven G.; Ganin, Alex; Lewellen, Thomas K.; Kinahan, Paul E.

    2008-01-01

    Partially collimated PET systems have less collimation than conventional 2-D systems and have been shown to offer count rate improvements over 2-D and 3-D systems. Despite this potential, previous efforts have not established image-based improvements with partial collimation and have not customized the reconstruction method for partially collimated data. This work presents an image reconstruction method tailored for partially collimated data. Simulated and measured sensitivity patterns are presented and provide a basis for modification of a fully 3-D reconstruction technique. The proposed method uses a measured normalization correction term to account for the unique sensitivity to true events. This work also proposes a modified scatter correction based on simulated data. Measured image quality data supports the use of the normalization correction term for true events, and suggests that the modified scatter correction is unnecessary. PMID:19096731

  16. Image Reconstruction for a Partially Collimated Whole Body PET Scanner.

    PubMed

    Alessio, Adam M; Schmitz, Ruth E; Macdonald, Lawrence R; Wollenweber, Scott D; Stearns, Charles W; Ross, Steven G; Ganin, Alex; Lewellen, Thomas K; Kinahan, Paul E

    2008-06-01

    Partially collimated PET systems have less collimation than conventional 2-D systems and have been shown to offer count rate improvements over 2-D and 3-D systems. Despite this potential, previous efforts have not established image-based improvements with partial collimation and have not customized the reconstruction method for partially collimated data. This work presents an image reconstruction method tailored for partially collimated data. Simulated and measured sensitivity patterns are presented and provide a basis for modification of a fully 3-D reconstruction technique. The proposed method uses a measured normalization correction term to account for the unique sensitivity to true events. This work also proposes a modified scatter correction based on simulated data. Measured image quality data supports the use of the normalization correction term for true events, and suggests that the modified scatter correction is unnecessary.

  17. Specific radioisotopic assay for cholinesterase. Technical report, December 1987-March 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talbot, B.G.; Anderson, D.R.; Harris, L.W.

    1990-05-01

    The radiometric method (I) for measuring ChE activity was modified to preclude the use of p-dioxane, a hazardous material. The modified procedure (II) uses 0.4 N perchloric acid (PCA), instead of p-dioxane, to denature the ChE and stop hydrolysis of 14C-acetylcholine (ACh). The unreacted substrate (ACh) is removed by cationic exchange resin suspended in water. The supernatant (acidic water solution) containing the product of hydrolysis, 14C-acetic acid, is mixed with nonhazardous scintillation cocktail and counted. The incubation mixture (37 degrees C) for II is similar to I and is composed of 0.1 ml of buffer-salt solution (pH 7.8), 0.1 mlmore » of guinea pig whole blood (WB)-water suspension and 0.1 ml of 3mM ACh solution.« less

  18. A Multiomics Approach to Identify Genes Associated with Childhood Asthma Risk and Morbidity.

    PubMed

    Forno, Erick; Wang, Ting; Yan, Qi; Brehm, John; Acosta-Perez, Edna; Colon-Semidey, Angel; Alvarez, Maria; Boutaoui, Nadia; Cloutier, Michelle M; Alcorn, John F; Canino, Glorisa; Chen, Wei; Celedón, Juan C

    2017-10-01

    Childhood asthma is a complex disease. In this study, we aim to identify genes associated with childhood asthma through a multiomics "vertical" approach that integrates multiple analytical steps using linear and logistic regression models. In a case-control study of childhood asthma in Puerto Ricans (n = 1,127), we used adjusted linear or logistic regression models to evaluate associations between several analytical steps of omics data, including genome-wide (GW) genotype data, GW methylation, GW expression profiling, cytokine levels, asthma-intermediate phenotypes, and asthma status. At each point, only the top genes/single-nucleotide polymorphisms/probes/cytokines were carried forward for subsequent analysis. In step 1, asthma modified the gene expression-protein level association for 1,645 genes; pathway analysis showed an enrichment of these genes in the cytokine signaling system (n = 269 genes). In steps 2-3, expression levels of 40 genes were associated with intermediate phenotypes (asthma onset age, forced expiratory volume in 1 second, exacerbations, eosinophil counts, and skin test reactivity); of those, methylation of seven genes was also associated with asthma. Of these seven candidate genes, IL5RA was also significant in analytical steps 4-8. We then measured plasma IL-5 receptor α levels, which were associated with asthma age of onset and moderate-severe exacerbations. In addition, in silico database analysis showed that several of our identified IL5RA single-nucleotide polymorphisms are associated with transcription factors related to asthma and atopy. This approach integrates several analytical steps and is able to identify biologically relevant asthma-related genes, such as IL5RA. It differs from other methods that rely on complex statistical models with various assumptions.

  19. Isolation of biologically active and morphologically intact exosomes from plasma of patients with cancer.

    PubMed

    Hong, Chang-Sook; Funk, Sonja; Muller, Laurent; Boyiadzis, Michael; Whiteside, Theresa L

    2016-01-01

    Isolation from human plasma of exosomes that retain functional and morphological integrity for probing their protein, lipid and nucleic acid content is a priority for the future use of exosomes as biomarkers. A method that meets these criteria and can be scaled up for patient monitoring is thus desirable. Plasma specimens (1 mL) of patients with acute myeloid leukaemia (AML) or a head and neck squamous cell carcinoma (HNSCC) were differentially centrifuged, ultrafiltered and fractionated by size exclusion chromatography in small disposable columns (mini-SEC). Exosomes were eluted in phosphate-buffered saline and were evaluated by qNano for particle size and counts, morphology by transmission electron microscopy, protein content, molecular profiles by western blots, and for ability to modify functions of immune cells. Exosomes eluting in fractions #3-5 had a diameter ranging from 50 to 200 nm by qNano, with the fraction #4 containing the bulk of clean, unaggregated exosomes. The exosome elution profiles remained constant for repeated runs of the same plasma. Larger plasma volumes could be fractionated running multiple mini-SEC columns in parallel. Particle concentrations per millilitre of plasma in #4 fractions of AML and HNSCC were comparable and were higher (p<0.003) than those in normal controls. Isolated AML exosomes co-incubated with normal human NK cells inhibited NKG2D expression levels (p<0.004), and HNSCC exosomes suppressed activation (p<0.01) and proliferation of activated T lymphocytes (p<0.03). Mini-SEC allows for simple and reproducible isolation from human plasma of exosomes retaining structural integrity and functional activity. It enables molecular/functional analysis of the exosome content in serial specimens of human plasma for clinical applications.

  20. Photon counting phosphorescence lifetime imaging with TimepixCam.

    PubMed

    Hirvonen, Liisa M; Fisher-Levine, Merlin; Suhling, Klaus; Nomerotski, Andrei

    2017-01-01

    TimepixCam is a novel fast optical imager based on an optimized silicon pixel sensor with a thin entrance window and read out by a Timepix Application Specific Integrated Circuit. The 256 × 256 pixel sensor has a time resolution of 15 ns at a sustained frame rate of 10 Hz. We used this sensor in combination with an image intensifier for wide-field time-correlated single photon counting imaging. We have characterised the photon detection capabilities of this detector system and employed it on a wide-field epifluorescence microscope to map phosphorescence decays of various iridium complexes with lifetimes of about 1 μs in 200 μm diameter polystyrene beads.

  1. Photon counting phosphorescence lifetime imaging with TimepixCam

    NASA Astrophysics Data System (ADS)

    Hirvonen, Liisa M.; Fisher-Levine, Merlin; Suhling, Klaus; Nomerotski, Andrei

    2017-01-01

    TimepixCam is a novel fast optical imager based on an optimized silicon pixel sensor with a thin entrance window and read out by a Timepix Application Specific Integrated Circuit. The 256 × 256 pixel sensor has a time resolution of 15 ns at a sustained frame rate of 10 Hz. We used this sensor in combination with an image intensifier for wide-field time-correlated single photon counting imaging. We have characterised the photon detection capabilities of this detector system and employed it on a wide-field epifluorescence microscope to map phosphorescence decays of various iridium complexes with lifetimes of about 1 μs in 200 μm diameter polystyrene beads.

  2. In-laboratory development of an automatic track counting system for solid state nuclear track detectors

    NASA Astrophysics Data System (ADS)

    Uzun, Sefa Kemal; Demiröz, Işık; Ulus, İzzet

    2017-01-01

    In this study, an automatic track counting system was developed for solid state nuclear track detectors (SSNTD). Firstly the specifications of required hardware components were determined, and accordingly the CCD camera, microscope and stage motor table was supplied and integrated. The system was completed by developing parametric software with VB.Net language. Finally a set of test intended for radon activity concentration measurement was applied. According to the test results, the system was enabled for routine radon measurement. Whether the parameters of system are adjusted for another SSNTD application, it could be used for other fields of SSNTD like neutron dosimetry or heavy charged particle detection.

  3. Beyond core count: a look at new mainstream computing platforms for HEP workloads

    NASA Astrophysics Data System (ADS)

    Szostek, P.; Nowak, A.; Bitzes, G.; Valsan, L.; Jarp, S.; Dotti, A.

    2014-06-01

    As Moore's Law continues to deliver more and more transistors, the mainstream processor industry is preparing to expand its investments in areas other than simple core count. These new interests include deep integration of on-chip components, advanced vector units, memory, cache and interconnect technologies. We examine these moving trends with parallelized and vectorized High Energy Physics workloads in mind. In particular, we report on practical experience resulting from experiments with scalable HEP benchmarks on the Intel "Ivy Bridge-EP" and "Haswell" processor families. In addition, we examine the benefits of the new "Haswell" microarchitecture and its impact on multiple facets of HEP software. Finally, we report on the power efficiency of new systems.

  4. Estimation and correction of visibility bias in aerial surveys of wintering ducks

    USGS Publications Warehouse

    Pearse, A.T.; Gerard, P.D.; Dinsmore, S.J.; Kaminski, R.M.; Reinecke, K.J.

    2008-01-01

    Incomplete detection of all individuals leading to negative bias in abundance estimates is a pervasive source of error in aerial surveys of wildlife, and correcting that bias is a critical step in improving surveys. We conducted experiments using duck decoys as surrogates for live ducks to estimate bias associated with surveys of wintering ducks in Mississippi, USA. We found detection of decoy groups was related to wetland cover type (open vs. forested), group size (1?100 decoys), and interaction of these variables. Observers who detected decoy groups reported counts that averaged 78% of the decoys actually present, and this counting bias was not influenced by either covariate cited above. We integrated this sightability model into estimation procedures for our sample surveys with weight adjustments derived from probabilities of group detection (estimated by logistic regression) and count bias. To estimate variances of abundance estimates, we used bootstrap resampling of transects included in aerial surveys and data from the bias-correction experiment. When we implemented bias correction procedures on data from a field survey conducted in January 2004, we found bias-corrected estimates of abundance increased 36?42%, and associated standard errors increased 38?55%, depending on species or group estimated. We deemed our method successful for integrating correction of visibility bias in an existing sample survey design for wintering ducks in Mississippi, and we believe this procedure could be implemented in a variety of sampling problems for other locations and species.

  5. Flexible ultrathin-body single-photon avalanche diode sensors and CMOS integration.

    PubMed

    Sun, Pengfei; Ishihara, Ryoichi; Charbon, Edoardo

    2016-02-22

    We proposed the world's first flexible ultrathin-body single-photon avalanche diode (SPAD) as photon counting device providing a suitable solution to advanced implantable bio-compatible chronic medical monitoring, diagnostics and other applications. In this paper, we investigate the Geiger-mode performance of this flexible ultrathin-body SPAD comprehensively and we extend this work to the first flexible SPAD image sensor with in-pixel and off-pixel electronics integrated in CMOS. Experimental results show that dark count rate (DCR) by band-to-band tunneling can be reduced by optimizing multiplication doping. DCR by trap-assisted avalanche, which is believed to be originated from the trench etching process, could be further reduced, resulting in a DCR density of tens to hundreds of Hertz per micrometer square at cryogenic temperature. The influence of the trench etching process onto DCR is also proved by comparison with planar ultrathin-body SPAD structures without trench. Photon detection probability (PDP) can be achieved by wider depletion and drift regions and by carefully optimizing body thickness. PDP in frontside- (FSI) and backside-illumination (BSI) are comparable, thus making this technology suitable for both modes of illumination. Afterpulsing and crosstalk are negligible at 2µs dead time, while it has been proved, for the first time, that a CMOS SPAD pixel of this kind could work in a cryogenic environment. By appropriate choice of substrate, this technology is amenable to implantation for biocompatible photon-counting applications and wherever bended imaging sensors are essential.

  6. Comparative investigation of the detective quantum efficiency of direct and indirect conversion detector technologies in dedicated breast CT.

    PubMed

    Kuttig, Jan D; Steiding, Christian; Kolditz, Daniel; Hupfer, Martin; Karolczak, Marek; Kalender, Willi A

    2015-06-01

    To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel energy-integrating detector with a 70 μm and a 208 μm thick gadolinium oxysulfide (GOS) and a 150 μm thick cesium iodide (CsI) scintillator and a photon-counting detector with a 1000 μm thick CdTe sensor. The measurements for GOS scintillator thicknesses of 70 μm and 208 μm delivered 10% pre-sampled MTF values of 6.6 mm(-1) and 3.2 mm(-1), and DQE(0) values of 23% and 61%. The 10% pre-sampled MTF value for the 150 μm thick CsI scintillator 6.9 mm(-1), and the DQE(0) value was 49%. The CdTe sensor reached a 10% pre-sampled MTF value of 8.5 mm(-1) and a DQE(0) value of 85%. The photon-counting CdTe detector technology allows for significant dose reduction compared to the energy-integrating scintillation detector technology used in BCT today. Our comparative evaluation indicates that a high potential dose saving may be possible for BCT by using CdTe detectors, without loss of spatial resolution. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Efficacy of disinfecting solutions in removing biofilms from polyvinyl chloride tracheostomy tubes.

    PubMed

    Silva, Rodrigo C; Carver, Ryan A; Ojano-Dirain, Carolyn P; Antonelli, Patrick J

    2013-01-01

    Bacterial biofilms are prevalent in pediatric tracheostomy tubes (TTs) and are not completely cleared by standard cleaning with gauze and household detergents. We aimed to examine the effectiveness of different disinfecting solutions to remove Staphylococcus aureus (SA) and Pseudomonas aerginosa (PA) biofilms from TTs. Prospective, controlled, in vitro microbiologic study. Uniform coupons obtained from polyvinyl chloride (PVC) pediatric TTs were briefly exposed to human plasma. The samples were incubated in growth media with either PA or SA for 7 days, and total bacterial growth was monitored by media turbidity. Five sets of 18 coupons each were exposed for 5 minutes to one of five different solutions: 2% aqueous chlorhexidine gluconate solution, 0.3% aqueous sodium hypochlorite, Polident denture cleanser, 3% hydrogen peroxide, or preservative-free phosphate-buffered saline (PBS) as a negative control. Biofilm presence was measured with bacterial counts, and surface integrity was assessed with scanning electron microscopy (SEM). All treatments significantly reduced mean SA counts (P = <.001). Sodium hypochlorite and chlorhexidine were more effective than peroxide and Polident. Chlorhexidine, sodium hypochlorite, and peroxide reduced PA counts (P = .001, .001, and .002, respectively), but Polident tabs had no significant effect. SEM revealed preserved TT surface integrity after exposure to all solutions. Disinfection with sodium hypochlorite or chlorhexidine solutions significantly reduces SA and PA biofilms on PVC TTs. Standard home care of reusable pediatric TTs may be improved by use of these readily available solutions. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  8. Resilience, Integrity and Ecosystem Dynamics: Bridging Ecosystem Theory and Management

    NASA Astrophysics Data System (ADS)

    Müller, Felix; Burkhard, Benjamin; Kroll, Franziska

    In this paper different approaches to elucidate ecosystem dynamics are described, illustrated and interrelated. Ecosystem development is distinguished into two separate sequences, a complexifying phase which is characterized by orientor optimization and a destruction based phase which follows disturbances. The two developmental pathways are integrated in a modified illustration of the "adaptive cycle". Based on these fundamentals, the recent definitions of resilience, adaptability and vulnerability are discussed and a modified comprehension is proposed. Thereafter, two case studies about wetland dynamics are presented to demonstrate both, the consequences of disturbance and the potential of ecosystem recovery. In both examples ecosystem integrity is used as a key indicator variable. Based on the presented results the relativity and the normative loading of resilience quantification is worked out. The paper ends with the suggestion that the features of adaptability could be used as an integrative guideline for the analysis of ecosystem dynamics and as a well-suited concept for ecosystem management.

  9. Neutron Detector Signal Processing to Calculate the Effective Neutron Multiplication Factor of Subcritical Assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talamo, Alberto; Gohar, Yousry

    2016-06-01

    This report describes different methodologies to calculate the effective neutron multiplication factor of subcritical assemblies by processing the neutron detector signals using MATLAB scripts. The subcritical assembly can be driven either by a spontaneous fission neutron source (e.g. californium) or by a neutron source generated from the interactions of accelerated particles with target materials. In the latter case, when the particle accelerator operates in a pulsed mode, the signals are typically stored into two files. One file contains the time when neutron reactions occur and the other contains the times when the neutron pulses start. In both files, the timemore » is given by an integer representing the number of time bins since the start of the counting. These signal files are used to construct the neutron count distribution from a single neutron pulse. The built-in functions of MATLAB are used to calculate the effective neutron multiplication factor through the application of the prompt decay fitting or the area method to the neutron count distribution. If the subcritical assembly is driven by a spontaneous fission neutron source, then the effective multiplication factor can be evaluated either using the prompt neutron decay constant obtained from Rossi or Feynman distributions or the Modified Source Multiplication (MSM) method.« less

  10. In vitro and in vivo killing of ocular Demodex by tea tree oil

    PubMed Central

    Gao, Y-Y; Di Pascuale, M A; Li, W; Baradaran-Rafii, A; Elizondo, A; Kuo, C-L; Raju, V K; Tseng, S C G

    2005-01-01

    Aims: To compare the in vitro killing effect of different agents on Demodex and to report the in vivo killing effect of tea tree oil (TTO) on ocular Demodex. Methods: Survival time of Demodex was measured under the microscope. Sampling and counting of Demodex was performed by a modified method. Results: Demodex folliculorum survived for more than 150 minutes in 10% povidone-iodine, 75% alcohol, 50% baby shampoo, and 4% pilocarpine. However, the survival time was significantly shortened to within 15 minutes in 100% alcohol, 100% TTO, 100% caraway oil, or 100% dill weed oil. TTO’s in vitro killing effect was dose dependent. Lid scrub with 50% TTO, but not with 50% baby shampoo, can further stimulate Demodex to move out to the skin. The Demodex count did not reach zero in any of the seven patients receiving daily lid scrub with baby shampoo for 40–350 days. In contrast, the Demodex count dropped to zero in seven of nine patients receiving TTO scrub in 4 weeks without recurrence. Conclusions: Demodex is resistant to a wide range of antiseptic solutions. Weekly lid scrub with 50% TTO and daily lid scrub with tea tree shampoo is effective in eradicating ocular Demodex. PMID:16234455

  11. A distortion of very-high-redshift galaxy number counts by gravitational lensing.

    PubMed

    Wyithe, J Stuart B; Yan, Haojing; Windhorst, Rogier A; Mao, Shude

    2011-01-13

    The observed number counts of high-redshift galaxy candidates have been used to build up a statistical description of star-forming activity at redshift z ≳ 7, when galaxies reionized the Universe. Standard models predict that a high incidence of gravitational lensing will probably distort measurements of flux and number of these earliest galaxies. The raw probability of this happening has been estimated to be ∼0.5 per cent (refs 11, 12), but can be larger owing to observational biases. Here we report that gravitational lensing is likely to dominate the observed properties of galaxies with redshifts of z ≳ 12, when the instrumental limiting magnitude is expected to be brighter than the characteristic magnitude of the galaxy sample. The number counts could be modified by an order of magnitude, with most galaxies being part of multiply imaged systems, located less than 1 arcsec from brighter foreground galaxies at z ≈ 2. This lens-induced association of high-redshift and foreground galaxies has perhaps already been observed among a sample of galaxy candidates identified at z ≈ 10.6. Future surveys will need to be designed to account for a significant gravitational lensing bias in high-redshift galaxy samples.

  12. High-speed MCP anodes for high time resolution low-energy charged particle spectrometers

    NASA Astrophysics Data System (ADS)

    Saito, Yoshifumi; Yokota, Shoichiro; Asamura, Kazushi; Krieger, Amanda

    2017-02-01

    The time resolution of low-energy charged particle measurements is becoming higher and higher. In order to realize high time resolution measurements, a 1-D circular delay line anode has been developed as a high-speed microchannel plate (MCP) anode. The maximum count rate of the 1-D circular delay line anode is around 1 × 107/s/360°, which is much higher than the widely used resistive anode, whose maximum count rate is around 1 × 106/s/360°. In order to achieve much higher speeds, an MCP anode with application-specific integrated circuit (ASIC) has been developed. We have decided to adopt an anode configuration in which a discrete anode is formed on a ceramic substrate, and a bare ASIC chip is installed on the back of the ceramic. It has been found that the anode can detect at a high count rate of 2 × 108/s/360°. Developments in both delay line and discrete anodes, as well as readout electronics, will be reviewed.

  13. Compact SPAD-Based Pixel Architectures for Time-Resolved Image Sensors

    PubMed Central

    Perenzoni, Matteo; Pancheri, Lucio; Stoppa, David

    2016-01-01

    This paper reviews the state of the art of single-photon avalanche diode (SPAD) image sensors for time-resolved imaging. The focus of the paper is on pixel architectures featuring small pixel size (<25 μm) and high fill factor (>20%) as a key enabling technology for the successful implementation of high spatial resolution SPAD-based image sensors. A summary of the main CMOS SPAD implementations, their characteristics and integration challenges, is provided from the perspective of targeting large pixel arrays, where one of the key drivers is the spatial uniformity. The main analog techniques aimed at time-gated photon counting and photon timestamping suitable for compact and low-power pixels are critically discussed. The main features of these solutions are the adoption of analog counting techniques and time-to-analog conversion, in NMOS-only pixels. Reliable quantum-limited single-photon counting, self-referenced analog-to-digital conversion, time gating down to 0.75 ns and timestamping with 368 ps jitter are achieved. PMID:27223284

  14. Multiple Revolution Solutions for the Perturbed Lambert Problem using the Method of Particular Solutions and Picard Iteration

    NASA Astrophysics Data System (ADS)

    Woollands, Robyn M.; Read, Julie L.; Probe, Austin B.; Junkins, John L.

    2017-12-01

    We present a new method for solving the multiple revolution perturbed Lambert problem using the method of particular solutions and modified Chebyshev-Picard iteration. The method of particular solutions differs from the well-known Newton-shooting method in that integration of the state transition matrix (36 additional differential equations) is not required, and instead it makes use of a reference trajectory and a set of n particular solutions. Any numerical integrator can be used for solving two-point boundary problems with the method of particular solutions, however we show that using modified Chebyshev-Picard iteration affords an avenue for increased efficiency that is not available with other step-by-step integrators. We take advantage of the path approximation nature of modified Chebyshev-Picard iteration (nodes iteratively converge to fixed points in space) and utilize a variable fidelity force model for propagating the reference trajectory. Remarkably, we demonstrate that computing the particular solutions with only low fidelity function evaluations greatly increases the efficiency of the algorithm while maintaining machine precision accuracy. Our study reveals that solving the perturbed Lambert's problem using the method of particular solutions with modified Chebyshev-Picard iteration is about an order of magnitude faster compared with the classical shooting method and a tenth-twelfth order Runge-Kutta integrator. It is well known that the solution to Lambert's problem over multiple revolutions is not unique and to ensure that all possible solutions are considered we make use of a reliable preexisting Keplerian Lambert solver to warm start our perturbed algorithm.

  15. Removing cosmic-ray hits from multiorbit HST Wide Field Camera images

    NASA Technical Reports Server (NTRS)

    Windhorst, Rogier A.; Franklin, Barbara E.; Neuschaefer, Lyman W.

    1994-01-01

    We present an optimized algorithm that removes cosmic rays ('CRs') from multiorbit Hubble Space Telescope (HST) Wide Field/Planetary Camera ('WF/PC') images. It computes the image noise in every iteration from the WF/PC CCD equation. This includes all known sources of random and systematic calibration errors. We test this algorithm on WF/PC stacks of 2-12 orbits as a function of the number of available orbits and the formal Poissonian sigma-clipping level. We find that the algorithm needs greater than or equal 4 WF/PC exposures to locate the minimal sky signal (which is noticeably affected by CRs), with an optimal clipping level at 2-2.5 x sigma(sub Poisson). We analyze the CR flux detected on multiorbit 'CR stacks,' which are constructed by subtracting the best CR filtered images from the unfiltered 8-12 orbit average. We use an automated object finder to determine the surface density of CRS as a function of the apparent magnitude (or ADU flux) they would have generated in the images had they not been removed. The power law slope of the CR 'counts' (gamma approximately = 0.6 for N(m) m(exp gamma)) is steeper than that of the faint galaxy counts down to V approximately = 28 mag. The CR counts show a drop off between 28 less than or approximately V less than or approximately 30 mag (the latter is our formal 2 sigma point source sensitivity without spherical aberration). This prevents the CR sky integral from diverging, and is likely due to a real cutoff in the CR energy distribution below approximately 11 ADU per orbit. The integral CR surface density is less than or approximately 10(exp 8)/sq. deg, and their sky signal is V approximately = 25.5-27.0 mag/sq. arcsec, or 3%-13% of our NEP sky background (V = 23.3 mag/sq. arcsec), and well above the EBL integral of the deepest galaxy counts (B(sub J) approximately = 28.0 mag/sq. arcsec). We conclude that faint CRs will always contribute to the sky signal in the deepest WF/PC images. Since WFPC2 has approximately 2.7x lower read noise and a thicker CCD, this will result in more CR detections than in WF/PC, potentially affecting approximately 10%-20% of the pixels in multiorbit WFPC2 data cubes.

  16. Survival of Staphylococcus pseudintermedius in modified Romanowsky staining solutions.

    PubMed

    Misan, Angus; Chan, Wei Yee; Trott, Darren; Hill, Peter B

    2017-08-01

    Stains that are used regularly for patient-side diagnosis to rapidly identify bacterial and fungal infections could become contaminated by common pathogens, such as Staphylococcus pseudintermedius, during slide immersion. To determine whether the inoculation of S. pseudintermedius into modified Romanowsky type stains (Quick Dip ® ) results in viable bacterial contamination and whether this is influenced by the addition of organic debris (canine hair and skin). A clinical isolate of S. pseudintermedius was inoculated into clean and organically contaminated Quick Dip ® solutions (methanol fixative, eosin, methylene blue), and positive (broth) and negative (bleach) controls. Each solution was tested for the presence of viable bacteria by counting the number of colony forming units (CFU/mL) at various time points. Solutions also were examined under high power microscopy to count the number of visible bacteria at each time point. Staphylococcus pseudintermedius was able to survive in the clean and contaminated Quick Dip ® stains for at least one hour, but by 24 h no viable bacteria remained. Survival of the bacteria was not supported in the fixative at any time point. Staphylococcus pseudintermedius remained visible under high power microscopy for up to 2 weeks in all organically contaminated solutions of the Quick Dip ® set. Staphylococcus pseudintermedius only remains viable in eosin and methylene blue for short periods of time, but the prolonged visibility of dead organisms could theoretically lead to the misdiagnosis of cytology samples. © 2017 ESVD and ACVD.

  17. Nonlinear wave choked inlets

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The quasi-one dimensional flow program was modified in two ways. The Runge-Kutta subroutine was replaced with a subroutine which used a modified divided difference form of the Adams Pece method and the matrix inversion routine was replaced with a pseudo inverse routine. Calculations were run using both the original and modified programs. Comparison of the calculations showed that the original Runge-Kutta routine could not detect singularity near the throat and was integrating across it. The modified version was able to detect the singularity and therefore gave more valid calculations.

  18. Solving Differential Equations Using Modified Picard Iteration

    ERIC Educational Resources Information Center

    Robin, W. A.

    2010-01-01

    Many classes of differential equations are shown to be open to solution through a method involving a combination of a direct integration approach with suitably modified Picard iterative procedures. The classes of differential equations considered include typical initial value, boundary value and eigenvalue problems arising in physics and…

  19. Relevant patient characteristics for guiding tailored integrated diabetes primary care: a systematic review.

    PubMed

    Hertroijs, Dorijn F L; Elissen, Arianne M J; Brouwers, Martijn C G J; Schaper, Nicolaas C; Ruwaard, Dirk

    2018-02-06

    Aim To identify which patient-related effect modifiers influence the outcomes of integrated care programs for type 2 diabetes in primary care. Integrated care is a widespread management strategy for the treatment of type 2 diabetes. However, most integrated care programs are not tailored to patients' needs, preferences and abilities. There is increasing consensus that such a patient-centered approach could improve the management of type 2 diabetes. Thus far, it remains unclear which patient-related effect modifiers should guide such an approach. PubMed, CINAHL and EMBASE were searched for empirical studies published after 1998. A systematic literature review was conducted according to the PRISMA guidelines. Findings In total, 23 out of 1015 studies were included. A total of 21 studies measured the effects of integrated diabetes care programs on hemoglobin A1c (HbA1c) and three on low-density lipoprotein cholesterol, systolic blood pressure and health-care utilization. In total, 49 patient characteristics were assessed as potential effect modifiers with HbA1c as an outcome, of which 46 were person or health-related and only three were context-related. Younger age, insulin therapy and longer disease duration were associated with higher HbA1c levels in cross-sectional and longitudinal studies. Higher baseline HbA1c was associated with higher HbA1c at follow-up in longitudinal studies. Information on context- and person-related characteristics was limited, but is necessary to help identify the care needs of individual patients and implement an effective integrated type 2 diabetes tailored care program.

  20. Bacterial community shift and incurred performance in response to in situ microbial self-assembly graphene and polarity reversion in microbial fuel cell.

    PubMed

    Chen, Junfeng; Zhang, Lihua; Hu, Yongyou; Huang, Wantang; Niu, Zhuyu; Sun, Jian

    2017-10-01

    In this work, bacterial community shift and incurred performance of graphene modified bioelectrode (GM-BE) in microbial fuel cell (MFC) were illustrated by high throughput sequencing technology and electrochemical analysis. The results showed that Firmicutes occupied 48.75% in graphene modified bioanode (GM-BA), while Proteobacteria occupied 62.99% in graphene modified biocathode (GM-BC), both were dominant bacteria in phylum level respectively. Typical exoelectrogens, including Geobacter, Clostridium, Pseudomonas, Geothrix and Hydrogenophaga, were counted 26.66% and 17.53% in GM-BA and GM-BC. GM-BE was tended to decrease the bacterial diversity and enrich the dominant species. Because of the enrichment of exoelectrogens and excellent electrical conductivity of graphene, the maximum power density of MFC with GM-BA and GM-BC increased 33.1% and 21.6% respectively, and the transfer resistance decreased 83.8% and 73.6% compared with blank bioelectrode. This study aimed to enrich the microbial study in MFC and broaden the development and application for bioelectrode. Copyright © 2017 Elsevier Ltd. All rights reserved.

Top