Sample records for modify code readability

  1. The Proteus Navier-Stokes code

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Bui, Trong T.; Cavicchi, Richard H.; Conley, Julianne M.; Molls, Frank B.; Schwab, John R.

    1992-01-01

    An effort is currently underway at NASA Lewis to develop two- and three-dimensional Navier-Stokes codes, called Proteus, for aerospace propulsion applications. The emphasis in the development of Proteus is not algorithm development or research on numerical methods, but rather the development of the code itself. The objective is to develop codes that are user-oriented, easily-modified, and well-documented. Well-proven, state-of-the-art solution algorithms are being used. Code readability, documentation (both internal and external), and validation are being emphasized. This paper is a status report on the Proteus development effort. The analysis and solution procedure are described briefly, and the various features in the code are summarized. The results from some of the validation cases that have been run are presented for both the two- and three-dimensional codes.

  2. The Exchange of Bibliographic Data in Non-Roman Scripts.

    ERIC Educational Resources Information Center

    Wellisch, Hans H.

    1980-01-01

    Advocates the use of machine readable codes to accomplish romanization and promote the exchange of bibliographic data. Proposals are presented for transliteration standards, design of machine readable conversion codes, and the establishment of databases. (RAA)

  3. Method and computer program product for maintenance and modernization backlogging

    DOEpatents

    Mattimore, Bernard G; Reynolds, Paul E; Farrell, Jill M

    2013-02-19

    According to one embodiment, a computer program product for determining future facility conditions includes a computer readable medium having computer readable program code stored therein. The computer readable program code includes computer readable program code for calculating a time period specific maintenance cost, for calculating a time period specific modernization factor, and for calculating a time period specific backlog factor. Future facility conditions equal the time period specific maintenance cost plus the time period specific modernization factor plus the time period specific backlog factor. In another embodiment, a computer-implemented method for calculating future facility conditions includes calculating a time period specific maintenance cost, calculating a time period specific modernization factor, and calculating a time period specific backlog factor. Future facility conditions equal the time period specific maintenance cost plus the time period specific modernization factor plus the time period specific backlog factor. Other embodiments are also presented.

  4. Comparative Readability Analysis of Online Patient Education Resources on Inflammatory Bowel Diseases.

    PubMed

    Gulati, Rishabh; Nawaz, Mohammad; Lam, Linh; Pyrsopoulos, Nikolaos T

    2017-01-01

    The National Institutes of Health recommend a readability grade level of less than 7th grade for patient directed information. In this study, we use validated readability metrics to analyze patient information from prominent websites pertaining to ulcerative colitis and Crohn's disease. The terms "Crohn's Disease," "Ulcerative Colitis," and "Inflammatory Bowel Disease" were queried on Google and Bing. Websites containing patient education material were saved as a text file and then modified through expungement of medical terminology that was described within the text. Modified text was then divided into subsections that were analyzed using six validated readability scales. None of the websites analyzed in this study achieved an estimated reading grade level below the recommended 7th grade. The median readability grade level (after modification) was 11.5 grade levels for both Crohn's disease and ulcerative colitis. The treatment subsection required the highest level of education with a median readability grade of 12th grade (range of 6.9 to 17). Readability of online patient education material from the analyzed popular websites far exceeds the recommended level of being less than 7th grade. Patient education resources should be revised to achieve wider health literacy.

  5. The incorporation of plotting capability into the Unified Subsonic Supersonic Aerodynamic Analysis program, version B

    NASA Technical Reports Server (NTRS)

    Winter, O. A.

    1980-01-01

    The B01 version of the United Subsonic Supersonic Aerodynamic Analysis program is the result of numerous modifications and additions made to the B00 version. These modifications and additions affect the program input, its computational options, the code readability, and the overlay structure. The following are described: (1) the revised input; (2) the plotting overlay programs which were also modified, and their associated subroutines, (3) the auxillary files used by the program, the revised output data; and (4) the program overlay structure.

  6. Proteus two-dimensional Navier-Stokes computer code, version 2.0. Volume 3: Programmer's reference

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 2D was developed to solve the two-dimensional planar or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. The Programmer's Reference contains detailed information useful when modifying the program. The program structure, the Fortran variables stored in common blocks, and the details of each subprogram are described.

  7. Proteus three-dimensional Navier-Stokes computer code, version 1.0. Volume 3: Programmer's reference

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 3D was developed to solve the three-dimensional, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. The Programmer's Reference contains detailed information useful when modifying the program. The program structure, the Fortran variables stored in common blocks, and the details of each subprogram are described.

  8. C++ Coding Standards and Style Guide

    NASA Technical Reports Server (NTRS)

    Hughes, Steven; Jun, Linda; Shoan, Wendy

    2005-01-01

    This document is based on the "C Style Guide" (SEL-94-003). It contains recommendations for C++ implementations that build on, or in some cases replace, the style described in the C style guide. Style guidelines on any topics that are not covered in this document can be found in the "C Style Guide." An attempt has been made to indicate when these recommendations are just guidelines or suggestions versus when they are more strongly encouraged. Using coding standards makes code easier to read and maintain. General principles that maximize the readability and maintainability of C++ are: (1) Organize classes using encapsulation and information hiding techniques. (2) Enhance readability through the use of indentation and blank lines. (3) Add comments to header files to help users of classes. (4) Add comments to implementation files to help maintainers of classes. (5) Create names that are meaningful and readable.

  9. Improving the readability and processability of a pediatric informed consent document: effects on parents' understanding.

    PubMed

    Tait, Alan R; Voepel-Lewis, Terri; Malviya, Shobha; Philipson, Sandra J

    2005-04-01

    To examine whether a consent document modified to conform with the federal guidelines for readability and processability would result in greater parental understanding compared with a standard form. Randomized clinical study. The preoperative waiting area of a larger tertiary care children's hospital. A total of 305 parents of children scheduled for minor elective surgical procedures. Parents were randomized to receive information about a clinical study in 1 of 4 ways: (1) standard consent form alone, (2) standard consent form with verbal disclosure, (3) modified form alone (standard form modified to meet the federal guidelines for readability and processability), and (4) modified form with verbal disclosure. Parents were interviewed to determine their understanding of 11 elements of consent, including study purpose, protocol, risks, benefits to child (direct), benefit to others (indirect), freedom to withdraw, alternatives, duration of study, voluntariness, confidentiality, and whom to contact. Their responses were scored by 2 independent assessors. Understanding of the protocol, study duration, risks, and direct benefits, together with overall understanding, was greater among parents who received the modified form (P<.001). Additionally, parents reported that the modified form had greater clarity (P = .009) and improved layout compared with the standard form (P<.001). When parents were shown both forms, 81.2% preferred the modified version. Results suggest that a consent form written according to federal guidelines for readability and processability can improve parent understanding and thus will be important in enhancing the informed consent process.

  10. Cauda equina syndrome: assessing the readability and quality of patient information on the Internet.

    PubMed

    O'Neill, Shane Ciaran; Baker, Joseph Frederick; Fitzgerald, Conall; Fleming, Christina; Rowan, Fiachra; Byrne, Damien; Synnott, Keith

    2014-05-01

    A readability and quality control Internet-based study using recognized quality scoring systems. To assess the readability and quality of Internet information relating to cauda equina syndrome accessed through common search engines. Access to health-related Internet information has increased dramatically during the past decade. A significant proportion of this information has been demonstrated to be set at too high a level for general comprehension. Despite this, searching for health-related information is now the third most popular online activity. A total of 125 cauda equina syndrome Web sites were analyzed from the 5 most popular Internet search engines: Google, Bing, Yahoo, Ask, and AOL. Web site authorship was classified: academic, physician, medico-legal, commercial, or discussion/social media. Readability of each Web site was assessed using the Flesch Reading Ease score, the Flesch-Kincaid grade level, and the Gunning Fog Index. Quality was calculated using the DISCERN instrument and The Journal of the American Medical Association benchmark criteria. The presence of HON-code certification was also assessed. Fifty-two individual Web sites were identified and assessed. The majority of Web sites were academic or physician compiled (53.8%; 28/52); however, a significant minority of Web sites were medico-legal related (19.2%; 10/52). Just 13.5% (7/52) of Web sites were at or below the recommended sixth-grade readability level. HON-code certified Web sites achieved significantly greater DISCERN (P = 0.0006) and The Journal of the American Medical Association (P = 0.0002) scores. Internet information relating to cauda equina syndrome is of variable quality and largely set at an inappropriate readability level. Given this variability in quality, health care providers should direct patients to known sources of reliable, readable online information. Identification of reliable sources may be aided by known markers of quality such as HON-code certification.

  11. 48 CFR 252.211-7003 - Item identification and valuation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...

  12. 48 CFR 252.211-7003 - Item identification and valuation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...

  13. 48 CFR 252.211-7003 - Item identification and valuation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...

  14. Basic Business and Economics: Understanding the Uses of the Universal Product Code

    ERIC Educational Resources Information Center

    Blockhus, Wanda

    1977-01-01

    Describes the Universal Product Code (UPC), the two-part food labeling and packaging code which is both human- and electronic scanner-readable. Discusses how it affects both consumer and business, and suggests how to teach the UPC code to business education students. (HD)

  15. Analyzing readability of medicines information material in Slovenia

    PubMed Central

    Kasesnik, Karin; Kline, Mihael

    2011-01-01

    Objective: Readability has been claimed to be an important factor for understanding texts describing health symptoms and medications. Such texts may be a factor which indirectly affects the health of the population. Despite the expertise of physicians, the readability of information sources may be important for acquiring essential treatment information. The aim of this study was to measure the readability level of medicines promotion material in Slovenia. Methods: The Flesch readability formula was modified to comply with Slovene texts. On the basis of determining the Slovene readability algorithm, the readability ease related to the readability grade level of different Slovene texts was established. In order to estimate an adjustment of the texts to the recommended readability grade level of the targeted population, readability values of English texts were set. One sample t-test and standard deviations from the arithmetic mean values were used as statistical tests. Results: The results of the research showed low readability scores of the Slovene texts. Difficult readability values were seen in different types of examined texts: in patient information leaflets, in the summaries of product characteristics, in promotional materials, while describing over-the-counter medications and in the materials for creating disease awareness. Especially low readability values were found within the texts belonging to promotional materials intended for the physicians. None of researched items, not even for the general public, were close to primary school grade readability levels and therefore could not be described as easily readable. Conclusion: This study provides an understanding of the level of readability of selected Slovene medicines information material. It was concluded that health-related texts were not compliant with general public or with healthcare professional needs. PMID:23093886

  16. Documentation for the machine-readable version of the revised new general catalogue of nonstellar astronomical objects

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1982-01-01

    The contents and format of the machine-readable version of the cataloque distributed by the Astronomical Data Center are described. Coding for the various scales and abbreviations used in the catalogue are tabulated and certain revisions to the machine version made to improve storage efficiency and notation are discussed.

  17. Evaluation of Factors Influencing Accuracy of Principal Procedure Coding Based on ICD-9-CM: An Iranian Study

    PubMed Central

    Farzandipour, Mehrdad; Sheikhtaheri, Abbas

    2009-01-01

    To evaluate the accuracy of procedural coding and the factors that influence it, 246 records were randomly selected from four teaching hospitals in Kashan, Iran. “Recodes” were assigned blindly and then compared to the original codes. Furthermore, the coders' professional behaviors were carefully observed during the coding process. Coding errors were classified as major or minor. The relations between coding accuracy and possible effective factors were analyzed by χ2 or Fisher exact tests as well as the odds ratio (OR) and the 95 percent confidence interval for the OR. The results showed that using a tabular index for rechecking codes reduces errors (83 percent vs. 72 percent accuracy). Further, more thorough documentation by the clinician positively affected coding accuracy, though this relation was not significant. Readability of records decreased errors overall (p = .003), including major ones (p = .012). Moreover, records with no abbreviations had fewer major errors (p = .021). In conclusion, not using abbreviations, ensuring more readable documentation, and paying more attention to available information increased coding accuracy and the quality of procedure databases. PMID:19471647

  18. PROTEUS two-dimensional Navier-Stokes computer code, version 1.0. Volume 3: Programmer's reference

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Benson, Thomas J.; Suresh, Ambady

    1990-01-01

    A new computer code was developed to solve the 2-D or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The thin-layer or Euler equations may also be solved. Turbulence is modeled using an algebraic eddy viscosity model. The objective was to develop a code for aerospace applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The equations are written in nonorthogonal body-fitted coordinates, and solved by marching in time using a fully-coupled alternating-direction-implicit procedure with generalized first- or second-order time differencing. All terms are linearized using second-order Taylor series. The boundary conditions are treated implicitly, and may be steady, unsteady, or spatially periodic. Simple Cartesian or polar grids may be generated internally by the program. More complex geometries require an externally generated computational coordinate system. The documentation is divided into three volumes. Volume 3 is the Programmer's Reference, and describes the program structure, the FORTRAN variables stored in common blocks, and the details of each subprogram.

  19. Bar Coding the U. S. Government Bill of Lading and the Material Inspection and Receiving Report.

    DTIC Science & Technology

    1984-12-01

    of respondents K because some of the replies did not respond to this question.) TABLE 3-2. DD 250 PROCESSING CAPABILITIES AUTOMiATED - BAR CODE...Proposed minimum data elements (both human readable and bar coded) required and why? (3) Proposed signature requirement changes and why? (4) Proposed

  20. An evaluation of Wikipedia as a resource for patient education in nephrology.

    PubMed

    Thomas, Garry R; Eng, Lawson; de Wolff, Jacob F; Grover, Samir C

    2013-01-01

    Wikipedia, a multilingual online encyclopedia, is a common starting point for patient medical searches. As its articles can be authored and edited by anyone worldwide, the credibility of the medical content of Wikipedia has been openly questioned. Wikipedia medical articles have also been criticized as too advanced for the general public. This study assesses the comprehensiveness, reliability, and readability of nephrology articles on Wikipedia. The International Statistical Classification of Diseases and Related problems, 10th Edition (ICD-10) diagnostic codes for nephrology (N00-N29.8) were used as a topic list to investigate the English Wikipedia database. Comprehensiveness was assessed by the proportion of ICD-10 codes that had corresponding articles. Reliability was measured by both the number of references per article and proportion of references from substantiated sources. Finally, readability was assessed using three validated indices (Flesch-Kincaid grade level, Automated readability index, and Flesch reading ease). Nephrology articles on Wikipedia were relatively comprehensive, with 70.5% of ICD-10 codes being represented. The articles were fairly reliable, with 7.1 ± 9.8 (mean ± SD) references per article, of which 59.7 ± 35.0% were substantiated references. Finally, all three readability indices determined that nephrology articles are written at a college level. Wikipedia is a comprehensive and fairly reliable medical resource for nephrology patients that is written at a college reading level. Accessibility of this information for the general public may be improved by hosting it at alternative Wikipedias targeted at a lower reading level, such as the Simple English Wikipedia. © 2013 Wiley Periodicals, Inc.

  1. PROTEUS two-dimensional Navier-Stokes computer code, version 1.0. Volume 1: Analysis description

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Benson, Thomas J.; Suresh, Ambady

    1990-01-01

    A new computer code was developed to solve the two-dimensional or axisymmetric, Reynolds averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The thin-layer or Euler equations may also be solved. Turbulence is modeled using an algebraic eddy viscosity model. The objective was to develop a code for aerospace applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The equations are written in nonorthogonal body-fitted coordinates, and solved by marching in time using a fully-coupled alternating direction-implicit procedure with generalized first- or second-order time differencing. All terms are linearized using second-order Taylor series. The boundary conditions are treated implicitly, and may be steady, unsteady, or spatially periodic. Simple Cartesian or polar grids may be generated internally by the program. More complex geometries require an externally generated computational coordinate system. The documentation is divided into three volumes. Volume 1 is the Analysis Description, and describes in detail the governing equations, the turbulence model, the linearization of the equations and boundary conditions, the time and space differencing formulas, the ADI solution procedure, and the artificial viscosity models.

  2. PROTEUS two-dimensional Navier-Stokes computer code, version 1.0. Volume 2: User's guide

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Benson, Thomas J.; Suresh, Ambady

    1990-01-01

    A new computer code was developed to solve the two-dimensional or axisymmetric, Reynolds averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The thin-layer or Euler equations may also be solved. Turbulence is modeled using an algebraic eddy viscosity model. The objective was to develop a code for aerospace applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The equations are written in nonorthogonal body-fitted coordinates, and solved by marching in time using a fully-coupled alternating direction-implicit procedure with generalized first- or second-order time differencing. All terms are linearized using second-order Taylor series. The boundary conditions are treated implicitly, and may be steady, unsteady, or spatially periodic. Simple Cartesian or polar grids may be generated internally by the program. More complex geometries require an externally generated computational coordinate system. The documentation is divided into three volumes. Volume 2 is the User's Guide, and describes the program's general features, the input and output, the procedure for setting up initial conditions, the computer resource requirements, the diagnostic messages that may be generated, the job control language used to run the program, and several test cases.

  3. Proteus three-dimensional Navier-Stokes computer code, version 1.0. Volume 2: User's guide

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 3D was developed to solve the three-dimensional, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This User's Guide describes the program's features, the input and output, the procedure for setting up initial conditions, the computer resource requirements, the diagnostic messages that may be generated, the job control language used to run the program, and several test cases.

  4. Exploring the Readability of Consent Forms in Human Research in the United States Army

    DTIC Science & Technology

    2005-03-01

    subjects: autonomy (respect for persons), beneficence, and justice. Readability of consent forms 12 The report also defined how these principles apply to...Regional Medical Command, Fort Sam Houston, Texas CPT Heidi P. Mon) U.S. Army-Baylor University Graduate Program in Health Care Administration March...United States v. Karl Brandt, 1947). The opinion in that case included 10 basic principles for human research, called the Nuremberg Code

  5. Colour Coding of Maps for Colour Deficient Observers.

    PubMed

    Røise, Anne Kari; Kvitle, Anne Kristin; Green, Phil

    2016-01-01

    We evaluate the colour coding of a web map traffic information service based on profiles simulating colour vision deficiencies. Based on these simulations and principles for universal design, we propose adjustments of the existing colours creating more readable maps for the colour vision deficient observers.

  6. Documentation for the machine readable version of the Yale Catalogue of the Positions and Proper Motions of Stars between Declinations -60 deg and -70 deg (Fallon 1983)

    NASA Technical Reports Server (NTRS)

    Roman, N. G.; Warren, W. H., Jr.

    1984-01-01

    The machine-readable, character-coded version of the catalog, as it is currently being distributed from the Astronomical Data Center(ADC), is described. The format and data provided in the magnetic tape version differ somewhat from those of the published catalog, which was also produced from a tape prepared at the ADC. The primary catalog data are positions and proper motions (equinox 1950.0) for 14597 stars.

  7. Oil and gas field code master list, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This document contains data collected through October 1993 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service.

  8. The role of readability in effective health communication: an experiment using a Japanese health information text on chronic suppurative otitis media.

    PubMed

    Sakai, Yukiko

    2013-09-01

    This study identifies the most significant readability factors and examines ways of improving and evaluating Japanese health information text in terms of ease of reading and understanding. Six different Japanese texts were prepared based on an original short text written by a medical doctor for a hospital web site intended for laypersons regarding chronic suppurative otitis media. Four were revised for single readability factor (syntax, vocabulary, or text structure) and two were modified in all three factors. Using a web-based survey, 270 high school students read one of the seven texts, including the original, completed two kinds of comprehension tests, and answered questions on their impressions of the text's readability. Significantly higher comprehension test scores were shown in the true or false test for a mixed text that presented important information first for better text structure. They were also found in the cloze test for a text using common vocabulary and a cohesive mixed text. Vocabulary could be a critical single readability factor when presumably combined with better text structure. Using multiple evaluation methods can help assess comprehensive readability. The findings on improvement and evaluation methods of readability can be applied to support effective health communication. © 2013 The authors. Health Information and Libraries Journal © 2013 Health Libraries Group Health Information and Libraries Journal.

  9. Evaluation of a 15-inch widescreen OLED with sunlight-readable resistive touch panel

    NASA Astrophysics Data System (ADS)

    Hufnagel, Bruce D.; Tchon, Joseph L.; Bahadur, Birendra

    2012-06-01

    A commercially available 15-inch active-matrix organic light-emitting diode (AMOLED) television was modified to include a sunlight-readable resistive touch panel for technical evaluation with regard to a variety of rugged military and aerospace applications. By removing the circular polarizer (CP) from the AMOLED and relying on the touch panel's CP, the authors were able to minimize change in display luminance while adding touch capability and reducing reflectance.

  10. Evaluation of Quality and Readability of Health Information Websites Identified through India's Major Search Engines.

    PubMed

    Raj, S; Sharma, V L; Singh, A J; Goel, S

    2016-01-01

    Background. The available health information on websites should be reliable and accurate in order to make informed decisions by community. This study was done to assess the quality and readability of health information websites on World Wide Web in India. Methods. This cross-sectional study was carried out in June 2014. The key words "Health" and "Information" were used on search engines "Google" and "Yahoo." Out of 50 websites (25 from each search engines), after exclusion, 32 websites were evaluated. LIDA tool was used to assess the quality whereas the readability was assessed using Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), and SMOG. Results. Forty percent of websites (n = 13) were sponsored by government. Health On the Net Code of Conduct (HONcode) certification was present on 50% (n = 16) of websites. The mean LIDA score (74.31) was average. Only 3 websites scored high on LIDA score. Only five had readability scores at recommended sixth-grade level. Conclusion. Most health information websites had average quality especially in terms of usability and reliability and were written at high readability levels. Efforts are needed to develop the health information websites which can help general population in informed decision making.

  11. Diabetes websites accredited by the Health On the Net Foundation Code of Conduct: readable or not?

    PubMed

    Kusec, Sanja; Brborovic, Ognjen; Schillinger, Dean

    2003-01-01

    Health information posted on the Internet has become a popular mode of communication with the population at large because millions of people now use the Internet to gather health information. Many studies on readability have shown that patient education information is frequently written at the reading level too high for the average population to understand, and the same holds true for health information on the Internet. The aim of this study was to determine the readability levels of health information found on diabetes-related websites displaying HONcode logo, which indicates to high quality of the information provided. The 99 websites tested for readability using the Flesch Reading Ease formula and Flesch-Kincaid level showed FRE score 2.1 to 79.6, with the mean 41.7 (10th grade, 8th month Flesch-Kincaid level), which indicates that 86.9% of these materials would be too difficult to read for the average adult population. It is suggested that the readability level, and the name of the formula used, be used on the websites themselves to help the Internet users decide which sites could be of the greatest benefit to them.

  12. Proteus two-dimensional Navier-Stokes computer code, version 2.0. Volume 1: Analysis description

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 2D was developed to solve the two-dimensional planar or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This is the Analysis Description, and presents the equations and solution procedure. The governing equations, the turbulence model, the linearization of the equations and boundary conditions, the time and space differencing formulas, the ADI solution procedure, and the artificial viscosity models are described in detail.

  13. Proteus three-dimensional Navier-Stokes computer code, version 1.0. Volume 1: Analysis description

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 3D has been developed to solve the three dimensional, Reynolds averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort has been to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation have been emphasized. The governing equations are solved in generalized non-orthogonal body-fitted coordinates by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This is the Analysis Description, and presents the equations and solution procedure. It describes in detail the governing equations, the turbulence model, the linearization of the equations and boundary conditions, the time and space differencing formulas, the ADI solution procedure, and the artificial viscosity models.

  14. Proteus two-dimensional Navier-Stokes computer code, version 2.0. Volume 2: User's guide

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Schwab, John R.; Bui, Trong T.

    1993-01-01

    A computer code called Proteus 2D was developed to solve the two-dimensional planar or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This is the User's Guide, and describes the program's features, the input and output, the procedure for setting up initial conditions, the computer resource requirements, the diagnostic messages that may be generated, the job control language used to run the program, and several test cases.

  15. Informed consent document improvement does not increase patients' comprehension in biomedical research

    PubMed Central

    Paris, Adeline; Brandt, Christian; Cornu, Catherine; Maison, Patrick; Thalamas, Claire; Cracowski, Jean-Luc

    2010-01-01

    AIMS International guidelines on ethics in biomedical research require that the informed consent of all enrolled participants is obtained. A written document describing the research, the informed consent (IC) document, must be given to all participants by the investigator. Most IC documents are long, containing much information. The aim of the present study was to determine whether the modification of the IC document by a working group or systematic improvement in its lexicosyntactic readability can improve comprehension of the written information given to patients participating in biomedical research. METHODS One hundred and fifty-nine patients were randomized to read one of the three versions of the IC document: unchanged document, document modified using systematic improvement of lexicosyntactic readability and document modified by a working group. RESULTS Neither the improvement in the lexicosyntactic readability, nor the intervention of the working group significantly improved the score of objective comprehension for the subjects included in this study: it was 66.6 (95% confidence interval 64.0, 69.2) for the control group, 68.8 (66.2, 71.4) for the group with the document improved for lexicosyntactic readability and 69.2 (66.0, 72.4) for the group who read the document improved by the working group (P= 0.38). CONCLUSIONS We failed to show that improving IC document comprehension through a lexicosyntactic approach or by a working group leads to better comprehension. PMID:20233193

  16. Practical guide to bar coding for patient medication safety.

    PubMed

    Neuenschwander, Mark; Cohen, Michael R; Vaida, Allen J; Patchett, Jeffrey A; Kelly, Jamie; Trohimovich, Barbara

    2003-04-15

    Bar coding for the medication administration step of the drug-use process is discussed. FDA will propose a rule in 2003 that would require bar-code labels on all human drugs and biologicals. Even with an FDA mandate, manufacturer procrastination and possible shifts in product availability are likely to slow progress. Such delays should not preclude health systems from adopting bar-code-enabled point-of-care (BPOC) systems to achieve gains in patient safety. Bar-code technology is a replacement for traditional keyboard data entry. The elements of bar coding are content, which determines the meaning; data format, which refers to the embedded data and symbology, which describes the "font" in which the machine-readable code is written. For a BPOC system to deliver an acceptable level of patient protection, the hospital must first establish reliable processes for a patient identification band, caregiver badge, and medication bar coding. Medications can have either drug-specific or patient-specific bar codes. Both varieties result in the desired code that supports patient's five rights of drug administration. When medications are not available from the manufacturer in immediate-container bar-coded packaging, other means of applying the bar code must be devised, including the use of repackaging equipment, overwrapping, manual bar coding, and outsourcing. Virtually all medications should be bar coded, the bar code on the label should be easily readable, and appropriate policies, procedures, and checks should be in place. Bar coding has the potential to be not only cost-effective but to produce a return on investment. By bar coding patient identification tags, caregiver badges, and immediate-container medications, health systems can substantially increase patient safety during medication administration.

  17. The Quality and Readability of Information Available on the Internet Regarding Lumbar Fusion

    PubMed Central

    Zhang, Dafang; Schumacher, Charles; Harris, Mitchel B.; Bono, Christopher M.

    2015-01-01

    Study Design An Internet-based evaluation of Web sites regarding lumbar fusion. Objective The Internet has become a major resource for patients; however, the quality and readability of Internet information regarding lumbar fusion is unclear. The objective of this study is to evaluate the quality and readability of Internet information regarding lumbar fusion and to determine whether these measures changed with Web site modality, complexity of the search term, or Health on the Net Code of Conduct certification. Methods Using five search engines and three different search terms of varying complexity (“low back fusion,” “lumbar fusion,” and “lumbar arthrodesis”), we identified and reviewed 153 unique Web site hits for information quality and readability. Web sites were specifically analyzed by search term and Web site modality. Information quality was evaluated on a 5-point scale. Information readability was assessed using the Flesch-Kincaid score for reading grade level. Results The average quality score was low. The average reading grade level was nearly six grade levels above that recommended by National Work Group on Literacy and Health. The quality and readability of Internet information was significantly dependent on Web site modality. The use of more complex search terms yielded information of higher reading grade level but not higher quality. Conclusions Higher-quality information about lumbar fusion conveyed using language that is more readable by the general public is needed on the Internet. It is important for health care providers to be aware of the information accessible to patients, as it likely influences their decision making regarding care. PMID:26933614

  18. The Quality and Readability of Information Available on the Internet Regarding Lumbar Fusion.

    PubMed

    Zhang, Dafang; Schumacher, Charles; Harris, Mitchel B; Bono, Christopher M

    2016-03-01

    Study Design An Internet-based evaluation of Web sites regarding lumbar fusion. Objective The Internet has become a major resource for patients; however, the quality and readability of Internet information regarding lumbar fusion is unclear. The objective of this study is to evaluate the quality and readability of Internet information regarding lumbar fusion and to determine whether these measures changed with Web site modality, complexity of the search term, or Health on the Net Code of Conduct certification. Methods Using five search engines and three different search terms of varying complexity ("low back fusion," "lumbar fusion," and "lumbar arthrodesis"), we identified and reviewed 153 unique Web site hits for information quality and readability. Web sites were specifically analyzed by search term and Web site modality. Information quality was evaluated on a 5-point scale. Information readability was assessed using the Flesch-Kincaid score for reading grade level. Results The average quality score was low. The average reading grade level was nearly six grade levels above that recommended by National Work Group on Literacy and Health. The quality and readability of Internet information was significantly dependent on Web site modality. The use of more complex search terms yielded information of higher reading grade level but not higher quality. Conclusions Higher-quality information about lumbar fusion conveyed using language that is more readable by the general public is needed on the Internet. It is important for health care providers to be aware of the information accessible to patients, as it likely influences their decision making regarding care.

  19. Ink-constrained halftoning with application to QR codes

    NASA Astrophysics Data System (ADS)

    Bayeh, Marzieh; Compaan, Erin; Lindsey, Theodore; Orlow, Nathan; Melczer, Stephen; Voller, Zachary

    2014-01-01

    This paper examines adding visually significant, human recognizable data into QR codes without affecting their machine readability by utilizing known methods in image processing. Each module of a given QR code is broken down into pixels, which are halftoned in such a way as to keep the QR code structure while revealing aspects of the secondary image to the human eye. The loss of information associated to this procedure is discussed, and entropy values are calculated for examples given in the paper. Numerous examples of QR codes with embedded images are included.

  20. Evaluation of Quality and Readability of Health Information Websites Identified through India's Major Search Engines

    PubMed Central

    Raj, S.; Sharma, V. L.; Singh, A. J.; Goel, S.

    2016-01-01

    Background. The available health information on websites should be reliable and accurate in order to make informed decisions by community. This study was done to assess the quality and readability of health information websites on World Wide Web in India. Methods. This cross-sectional study was carried out in June 2014. The key words “Health” and “Information” were used on search engines “Google” and “Yahoo.” Out of 50 websites (25 from each search engines), after exclusion, 32 websites were evaluated. LIDA tool was used to assess the quality whereas the readability was assessed using Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), and SMOG. Results. Forty percent of websites (n = 13) were sponsored by government. Health On the Net Code of Conduct (HONcode) certification was present on 50% (n = 16) of websites. The mean LIDA score (74.31) was average. Only 3 websites scored high on LIDA score. Only five had readability scores at recommended sixth-grade level. Conclusion. Most health information websites had average quality especially in terms of usability and reliability and were written at high readability levels. Efforts are needed to develop the health information websites which can help general population in informed decision making. PMID:27119025

  1. Informed consent recall and comprehension in orthodontics: traditional vs improved readability and processability methods.

    PubMed

    Kang, Edith Y; Fields, Henry W; Kiyak, Asuman; Beck, F Michael; Firestone, Allen R

    2009-10-01

    Low general and health literacy in the United States means informed consent documents are not well understood by most adults. Methods to improve recall and comprehension of informed consent have not been tested in orthodontics. The purposes of this study were to evaluate (1) recall and comprehension among patients and parents by using the American Association of Orthodontists' (AAO) informed consent form and new forms incorporating improved readability and processability; (2) the association between reading ability, anxiety, and sociodemographic variables and recall and comprehension; and (3) how various domains (treatment, risk, and responsibility) of information are affected by the forms. Three treatment groups (30 patient-parent pairs in each) received an orthodontic case presentation and either the AAO form, an improved readability form (MIC), or an improved readability and processability (pairing audio and visual cues) form (MIC + SS). Structured interviews were transcribed and coded to evaluate recall and comprehension. Significant relationships among patient-related variables and recall and comprehension explained little of the variance. The MIC + SS form significantly improved patient recall and parent recall and comprehension. Recall was better than comprehension, and parents performed better than patients. The MIC + SS form significantly improved patient treatment comprehension and risk recall and parent treatment recall and comprehension. Patients and parents both overestimated their understanding of the materials. Improving the readability of consent materials made little difference, but combining improved readability and processability benefited both patients' recall and parents' recall and comprehension compared with the AAO form.

  2. Understanding and Writing G & M Code for CNC Machines

    ERIC Educational Resources Information Center

    Loveland, Thomas

    2012-01-01

    In modern CAD and CAM manufacturing companies, engineers design parts for machines and consumable goods. Many of these parts are cut on CNC machines. Whether using a CNC lathe, milling machine, or router, the ideas and designs of engineers must be translated into a machine-readable form called G & M Code that can be used to cut parts to precise…

  3. California State Library: Processing Center Design and Specifications. Volume III, Coding Manual.

    ERIC Educational Resources Information Center

    Sherman, Don; Shoffner, Ralph M.

    As part of the report on the California State Library Processing Center design and specifications, this volume is a coding manual for the conversion of catalog card data to a machine-readable form. The form is compatible with the national MARC system, while at the same time it contains provisions for problems peculiar to the local situation. This…

  4. Radio-nuclide mixture identification using medium energy resolution detectors

    DOEpatents

    Nelson, Karl Einar

    2013-09-17

    According to one embodiment, a method for identifying radio-nuclides includes receiving spectral data, extracting a feature set from the spectral data comparable to a plurality of templates in a template library, and using a branch and bound method to determine a probable template match based on the feature set and templates in the template library. In another embodiment, a device for identifying unknown radio-nuclides includes a processor, a multi-channel analyzer, and a memory operatively coupled to the processor, the memory having computer readable code stored thereon. The computer readable code is configured, when executed by the processor, to receive spectral data, to extract a feature set from the spectral data comparable to a plurality of templates in a template library, and to use a branch and bound method to determine a probable template match based on the feature set and templates in the template library.

  5. Documentation for the machine-readable version of the general catalogue of 33342 stars for the epoch 1950 (Boss 1937)

    NASA Technical Reports Server (NTRS)

    Roman, N. G.; Warren, W. H., Jr.

    1983-01-01

    A revised and corrected version of the machine-readable catalog has been prepared. Cross identifications of the GC stars to the HD and DM catalogs have been replaced by data from the new SAO-HD-GC-DM Cross Index (Roman, Warren and Schofield 1983), including component identifications for multiple SAO entries having identical DM numbers in the SAO Catalog, supplemental Bonner Durchmusterung stars (lower case letter designations) and codes for multiple HD stars. Additional individual corrections have been incorporated based upon errors found during analyses of other catalogs.

  6. Bar Code Labels

    NASA Technical Reports Server (NTRS)

    1988-01-01

    American Bar Codes, Inc. developed special bar code labels for inventory control of space shuttle parts and other space system components. ABC labels are made in a company-developed anodizing aluminum process and consecutively marketed with bar code symbology and human readable numbers. They offer extreme abrasion resistance and indefinite resistance to ultraviolet radiation, capable of withstanding 700 degree temperatures without deterioration and up to 1400 degrees with special designs. They offer high resistance to salt spray, cleaning fluids and mild acids. ABC is now producing these bar code labels commercially or industrial customers who also need labels to resist harsh environments.

  7. Readability Formulas and User Perceptions of Electronic Health Records Difficulty: A Corpus Study

    PubMed Central

    Yu, Hong

    2017-01-01

    Background Electronic health records (EHRs) are a rich resource for developing applications to engage patients and foster patient activation, thus holding a strong potential to enhance patient-centered care. Studies have shown that providing patients with access to their own EHR notes may improve the understanding of their own clinical conditions and treatments, leading to improved health care outcomes. However, the highly technical language in EHR notes impedes patients’ comprehension. Numerous studies have evaluated the difficulty of health-related text using readability formulas such as Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning-Fog Index (GFI). They conclude that the materials are often written at a grade level higher than common recommendations. Objective The objective of our study was to explore the relationship between the aforementioned readability formulas and the laypeople’s perceived difficulty on 2 genres of text: general health information and EHR notes. We also validated the formulas’ appropriateness and generalizability on predicting difficulty levels of highly complex technical documents. Methods We collected 140 Wikipedia articles on diabetes and 242 EHR notes with diabetes International Classification of Diseases, Ninth Revision code. We recruited 15 Amazon Mechanical Turk (AMT) users to rate difficulty levels of the documents. Correlations between laypeople’s perceived difficulty levels and readability formula scores were measured, and their difference was tested. We also compared word usage and the impact of medical concepts of the 2 genres of text. Results The distributions of both readability formulas’ scores (P<.001) and laypeople’s perceptions (P=.002) on the 2 genres were different. Correlations of readability predictions and laypeople’s perceptions were weak. Furthermore, despite being graded at similar levels, documents of different genres were still perceived with different difficulty (P<.001). Word usage in the 2 related genres still differed significantly (P<.001). Conclusions Our findings suggested that the readability formulas’ predictions did not align with perceived difficulty in either text genre. The widely used readability formulas were highly correlated with each other but did not show adequate correlation with readers’ perceived difficulty. Therefore, they were not appropriate to assess the readability of EHR notes. PMID:28254738

  8. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    PubMed

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  9. Method of modifying a volume mesh using sheet extraction

    DOEpatents

    Borden, Michael J [Albuquerque, NM; Shepherd, Jason F [Albuquerque, NM

    2007-02-20

    A method and machine-readable medium provide a technique to modify a hexahedral finite element volume mesh using dual generation and sheet extraction. After generating a dual of a volume stack (mesh), a predetermined algorithm may be followed to modify the volume mesh of hexahedral elements. The predetermined algorithm may include the steps of determining a sheet of hexahedral mesh elements, generating nodes for merging, and merging the nodes to delete the sheet of hexahedral mesh elements and modify the volume mesh.

  10. 75 FR 80426 - Defense Federal Acquisition Regulation Supplement; Reporting of Government-Furnished Property

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... number. (vii) Medium code; how the data is recorded, e.g., barcode, contact memory button. (viii) Value, e.g., actual text or data string that is recorded in its human-readable form. (ix) Set (used to...

  11. Automatic Certification of Kalman Filters for Reliable Code Generation

    NASA Technical Reports Server (NTRS)

    Denney, Ewen; Fischer, Bernd; Schumann, Johann; Richardson, Julian

    2005-01-01

    AUTOFILTER is a tool for automatically deriving Kalman filter code from high-level declarative specifications of state estimation problems. It can generate code with a range of algorithmic characteristics and for several target platforms. The tool has been designed with reliability of the generated code in mind and is able to automatically certify that the code it generates is free from various error classes. Since documentation is an important part of software assurance, AUTOFILTER can also automatically generate various human-readable documents, containing both design and safety related information. We discuss how these features address software assurance standards such as DO-178B.

  12. Development of SMOG-Cro readability formula for healthcare communication and patient education.

    PubMed

    Brangan, Sanja

    2015-03-01

    Effective communication shows a positive impact on patient satisfaction, compliance and medical outcomes, at the same time reducing the healthcare costs. Written information for patients needs to correspond to health literacy levels of the intended audiences. Readability formulas correlate well with the reading and comprehension tests but are considered an easier and quicker method to estimate a text difficulty. SMOG readability formula designed for English language needs to be modified if used for texts in other languages. The aim of this study was to develop a readability formula based on SMOG, that could be used to estimate text difficulty of written materials for patients in Croatian language. Contras- tive analysis of English and Croatian language covering a corpus of almost 100,000 running words showed clear linguis- tic differences in the number of polysyllabic words. The new formula, named SMOG-Cro, is presented as an equation: SMOG-Cro = 2 + √4+ syllables, with the score showing the number of years of education a person needs to be able to understand a piece of writing. The presented methodology could help in the development of readability formulas for other languages. We hope the results of this study are soon put into practice for more effective healthcare communication and patient education, and for development of a health literacy assessment tool in Croatian language.

  13. Third Molars on the Internet: A Guide for Assessing Information Quality and Readability.

    PubMed

    Hanna, Kamal; Brennan, David; Sambrook, Paul; Armfield, Jason

    2015-10-06

    Directing patients suffering from third molars (TMs) problems to high-quality online information is not only medically important, but also could enable better engagement in shared decision making. This study aimed to develop a scale that measures the scientific information quality (SIQ) for online information concerning wisdom tooth problems and to conduct a quality evaluation for online TMs resources. In addition, the study evaluated whether a specific piece of readability software (Readability Studio Professional 2012) might be reliable in measuring information comprehension, and explored predictors for the SIQ Scale. A cross-sectional sample of websites was retrieved using certain keywords and phrases such as "impacted wisdom tooth problems" using 3 popular search engines. The retrieved websites (n=150) were filtered. The retained 50 websites were evaluated to assess their characteristics, usability, accessibility, trust, readability, SIQ, and their credibility using DISCERN and Health on the Net Code (HoNCode). Websites' mean scale scores varied significantly across website affiliation groups such as governmental, commercial, and treatment provider bodies. The SIQ Scale had a good internal consistency (alpha=.85) and was significantly correlated with DISCERN (r=.82, P<.01) and HoNCode (r=.38, P<.01). Less than 25% of websites had SIQ scores above 75%. The mean readability grade (10.3, SD 1.9) was above the recommended level, and was significantly correlated with the Scientific Information Comprehension Scale (r=.45. P<.01), which provides evidence for convergent validity. Website affiliation and DISCERN were significantly associated with SIQ (P<.01) and explained 76% of the SIQ variance. The developed SIQ Scale was found to demonstrate reliability and initial validity. Website affiliation, DISCERN, and HoNCode were significant predictors for the quality of scientific information. The Readability Studio software estimates were associated with scientific information comprehensiveness measures.

  14. Prostate Cancer Information Available in Health-Care Provider Offices: An Analysis of Content, Readability, and Cultural Sensitivity.

    PubMed

    Choi, Seul Ki; Seel, Jessica S; Yelton, Brooks; Steck, Susan E; McCormick, Douglas P; Payne, Johnny; Minter, Anthony; Deutchki, Elizabeth K; Hébert, James R; Friedman, Daniela B

    2018-07-01

    Prostate cancer (PrCA) is the most common cancer affecting men in the United States, and African American men have the highest incidence among men in the United States. Little is known about the PrCA-related educational materials being provided to patients in health-care settings. Content, readability, and cultural sensitivity of materials available in providers' practices in South Carolina were examined. A total of 44 educational materials about PrCA and associated sexual dysfunction was collected from 16 general and specialty practices. The content of the materials was coded, and cultural sensitivity was assessed using the Cultural Sensitivity Assessment Tool. Flesch Reading Ease, Flesch-Kincaid Grade Level, and the Simple Measure of Gobbledygook were used to assess readability. Communication with health-care providers (52.3%), side effects of PrCA treatment (40.9%), sexual dysfunction and its treatment (38.6%), and treatment options (34.1%) were frequently presented. All materials had acceptable cultural sensitivity scores; however, 2.3% and 15.9% of materials demonstrated unacceptable cultural sensitivity regarding format and visual messages, respectively. Readability of the materials varied. More than half of the materials were written above a high-school reading level. PrCA-related materials available in health-care practices may not meet patients' needs regarding content, cultural sensitivity, and readability. A wide range of educational materials that address various aspects of PrCA, including treatment options and side effects, should be presented in plain language and be culturally sensitive.

  15. Readability Formulas and User Perceptions of Electronic Health Records Difficulty: A Corpus Study.

    PubMed

    Zheng, Jiaping; Yu, Hong

    2017-03-02

    Electronic health records (EHRs) are a rich resource for developing applications to engage patients and foster patient activation, thus holding a strong potential to enhance patient-centered care. Studies have shown that providing patients with access to their own EHR notes may improve the understanding of their own clinical conditions and treatments, leading to improved health care outcomes. However, the highly technical language in EHR notes impedes patients' comprehension. Numerous studies have evaluated the difficulty of health-related text using readability formulas such as Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning-Fog Index (GFI). They conclude that the materials are often written at a grade level higher than common recommendations. The objective of our study was to explore the relationship between the aforementioned readability formulas and the laypeople's perceived difficulty on 2 genres of text: general health information and EHR notes. We also validated the formulas' appropriateness and generalizability on predicting difficulty levels of highly complex technical documents. We collected 140 Wikipedia articles on diabetes and 242 EHR notes with diabetes International Classification of Diseases, Ninth Revision code. We recruited 15 Amazon Mechanical Turk (AMT) users to rate difficulty levels of the documents. Correlations between laypeople's perceived difficulty levels and readability formula scores were measured, and their difference was tested. We also compared word usage and the impact of medical concepts of the 2 genres of text. The distributions of both readability formulas' scores (P<.001) and laypeople's perceptions (P=.002) on the 2 genres were different. Correlations of readability predictions and laypeople's perceptions were weak. Furthermore, despite being graded at similar levels, documents of different genres were still perceived with different difficulty (P<.001). Word usage in the 2 related genres still differed significantly (P<.001). Our findings suggested that the readability formulas' predictions did not align with perceived difficulty in either text genre. The widely used readability formulas were highly correlated with each other but did not show adequate correlation with readers' perceived difficulty. Therefore, they were not appropriate to assess the readability of EHR notes. ©Jiaping Zheng, Hong Yu. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 02.03.2017.

  16. Vector-matrix-quaternion, array and arithmetic packages: All HAL/S functions implemented in Ada

    NASA Technical Reports Server (NTRS)

    Klumpp, Allan R.; Kwong, David D.

    1986-01-01

    The HAL/S avionics programmers have enjoyed a variety of tools built into a language tailored to their special requirements. Ada is designed for a broader group of applications. Rather than providing built-in tools, Ada provides the elements with which users can build their own. Standard avionic packages remain to be developed. These must enable programmers to code in Ada as they have coded in HAL/S. The packages under development at JPL will provide all of the vector-matrix, array, and arithmetic functions described in the HAL/S manuals. In addition, the linear algebra package will provide all of the quaternion functions used in Shuttle steering and Galileo attitude control. Furthermore, using Ada's extensibility, many quaternion functions are being implemented as infix operations; equivalent capabilities were never implemented in HAL/S because doing so would entail modifying the compiler and expanding the language. With these packages, many HAL/S expressions will compile and execute in Ada, unchanged. Others can be converted simply by replacing the implicit HAL/S multiply operator with the Ada *. Errors will be trapped and identified. Input/output will be convenient and readable.

  17. Evaluation of websites that contain information relating to malaria in pregnancy.

    PubMed

    Hamwela, V; Ahmed, W; Bath, P A

    2018-04-01

    The study identified available websites on malaria in pregnancy on the World Wide Web and sought to evaluate their readability and information quality. A purposeful sample of websites were selected which provided information on Malaria in pregnancy. A total of 31 websites were identified from searches using Google, Yahoo and Bing search engines. Two generic tools (Discern and HON), one specific tool designed to assess information quality of malaria in pregnancy and readability tests (Flesch Reading Ease and Flesh-Kincaid Grade level) were used to evaluate the websites. Most of the websites scored below 50% with the HON Code tool, with most lacking information on the symptoms. One website scored over 70 with the reading ease with two (2) achieving a score of 7 for the reading level test. The readability of the websites was too advanced for an ordinary consumer. The results of this study indicated that the information quality of malaria in pregnancy websites varied from fair to medium. It was also found that the readability of the websites was too advanced for an ordinary consumer. These findings suggest that most websites are not comprehensive in addressing all the relevant aspects of malaria in pregnancy. Copyright © 2018 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  18. 48 CFR 252.211-7003 - Item identification and valuation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... Defense Logistics Information System (DLIS) Commercial and Government Entity (CAGE) Code). Issuing agency... identifier. Item means a single hardware article or a single unit formed by a grouping of subassemblies...

  19. Accuracy and readability of cardiovascular entries on Wikipedia: are they reliable learning resources for medical students?

    PubMed Central

    Azer, Samy A; AlSwaidan, Nourah M; Alshwairikh, Lama A; AlShammari, Jumana M

    2015-01-01

    Objective To evaluate accuracy of content and readability level of English Wikipedia articles on cardiovascular diseases, using quality and readability tools. Methods Wikipedia was searched on the 6 October 2013 for articles on cardiovascular diseases. Using a modified DISCERN (DISCERN is an instrument widely used in assessing online resources), articles were independently scored by three assessors. The readability was calculated using Flesch-Kincaid Grade Level. The inter-rater agreement between evaluators was calculated using the Fleiss κ scale. Results This study was based on 47 English Wikipedia entries on cardiovascular diseases. The DISCERN scores had a median=33 (IQR=6). Four articles (8.5%) were of good quality (DISCERN score 40–50), 39 (83%) moderate (DISCERN 30–39) and 4 (8.5%) were poor (DISCERN 10–29). Although the entries covered the aetiology and the clinical picture, there were deficiencies in the pathophysiology of diseases, signs and symptoms, diagnostic approaches and treatment. The number of references varied from 1 to 127 references; 25.9±29.4 (mean±SD). Several problems were identified in the list of references and citations made in the articles. The readability of articles was 14.3±1.7 (mean±SD); consistent with the readability level for college students. In comparison, Harrison’s Principles of Internal Medicine 18th edition had more tables, less references and no significant difference in number of graphs, images, illustrations or readability level. The overall agreement between the evaluators was good (Fleiss κ 0.718 (95% CI 0.57 to 0.83). Conclusions The Wikipedia entries are not aimed at a medical audience and should not be used as a substitute to recommended medical resources. Course designers and students should be aware that Wikipedia entries on cardiovascular diseases lack accuracy, predominantly due to errors of omission. Further improvement of the Wikipedia content of cardiovascular entries would be needed before they could be considered a supplementary resource. PMID:26443650

  20. Preprocessor that Enables the Use of GridProTM Grids for Unsteady Reynolds-Averaged Navier-Stokes Code TURBO

    NASA Technical Reports Server (NTRS)

    Shyam, Vikram

    2010-01-01

    A preprocessor for the Computational Fluid Dynamics (CFD) code TURBO has been developed and tested. The preprocessor converts grids produced by GridPro (Program Development Company (PDC)) into a format readable by TURBO and generates the necessary input files associated with the grid. The preprocessor also generates information that enables the user to decide how to allocate the computational load in a multiple block per processor scenario.

  1. Translation of one high-level language to another: COBOL to ADA, an example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, J.A.

    1986-01-01

    This dissertation discusses the difficulties encountered in, and explores possible solutions to, the task of automatically converting programs written in one HLL, COBOL, into programs written in another HLL, Ada, and still maintain readability. This paper presents at least one set of techniques and algorithms to solve many of the problems that were encountered. The differing view of records is solved by isolating those instances where it is a problem, then using the RENAMES option of Ada. Several solutions to doing the decimal-arithmetic translation are discussed. One method used is to emulate COBOL arithmetic in an arithmetic package. Another partialmore » solution suggested is to convert the values to decimal-scaled integers and use modular arithmetic. Conversion to fixed-point type and floating-point type are the third and fourth methods. The work of another researcher, Bobby Othmer, is utilized to correct any unstructured code, to remap statements not directly translatable such as ALTER, and to pull together isolated code sections. Algorithms are then presented to convert this restructured COBOL code into Ada code with local variables, parameters, and packages. The input/output requirements are partially met by mapping them to a series of procedure calls that interface with Ada's standard input-output package. Several examples are given of hand translations of COBOL programs. In addition, a possibly new method is shown for measuring the readability of programs.« less

  2. Passive sampling methods to determine household and personal care product use.

    PubMed

    Bennett, Deborah H; Wu, Xiangmei May; Teague, Candice H; Lee, Kiyoung; Cassady, Diana L; Ritz, Beate; Hertz-Picciotto, Irva

    2012-01-01

    Traditionally, use of household and personal care products has been collected through questionnaires, which is very time consuming, a burden on participants, and prone to recall bias. As part of the SUPERB Project (Study of Use of Products and Exposure-Related Behaviors), a novel platform was developed using bar codes to quickly and reliably determine what household and personal care products people have in their homes and determine the amount used over a 1-week period. We evaluated the acceptability and feasibility of our methodology in a longitudinal field study that included 47 California households, 30 with young children and 17 with an older adult. Acceptability was defined by refusal rates; feasibility was evaluated in terms of readable bar codes, useful product information in our database for all readable barcodes, and ability to find containers at both the start and end of the week. We found 63% of personal care products and 87% of the household care products had readable barcodes with 47% and 41% having sufficient data for product identification, respectively and secondly, the amount used could be determined most of the time. We present distributions for amount used by product category and compare inter- and intra-person variability. In summary, our method appears to be appropriate, acceptable, and useful for gathering information related to potential exposures stemming from the use of personal and household care products. A very low drop-out rate suggests that this methodology can be useful in longitudinal studies of exposure to household and personal care products.

  3. Assessment of the quality of patient-oriented information over internet on testicular cancer.

    PubMed

    Prasanth, Anton S; Jayarajah, Umesh; Mohanappirian, Ranganathan; Seneviratne, Sanjeewa A

    2018-05-02

    This study aimed to assess the quality and readability of patient education information available on the internet on testicular cancer. Internet searches were performed using the keywords 'testicular cancer', 'testicular tumour', 'testicular tumor', 'testicular malignancy', 'germ cell tumour' and 'germ cell tumor' using Google, Yahoo! And Bing search engines with default settings. The first 50 web links appeared in each search engine were evaluated for their readability by using the validated Flesch Reading Ease Score (FRES) while accessibility, usability and reliability were assessed using the LIDA tool. The quality was assessed using DISCERN instrument. Non-parametric tests were used for statistical analysis. Overall, 900 websites were assessed and 62 websites were included in the analysis. Twenty two (22) websites (35.5%) were certified by Health on the Net Foundation code of conduct (HON code). The majority (n = 57, 91.9%) were non-governmental websites. The median FRES score was 51.6 (range: 28.1-74.1), the overall median LIDA score was 115 (range: 81-147); accessibility 55 (range: 46-61), reliability 22 (range: 8-45) and usability 38.5 (range: 21-50), while the median DISCERN score was 43.5 (range: 16-69). The DISCERN score was significantly associated with the overall LIDA score and usability and reliability components of the LIDA score (p < 0.001). However, no significant associations were observed between readability and accessibility. A significant correlation was noted between usability and reliability components of the LIDA score (Spearman's rho: 0.789, p < 0.001). In this study, the readability, reliability and quality scores of most websites were found to be suboptimal and hence, there is potential for improvement. As the internet is expanding rapidly as a readily available source of information to the public, it is essential to implement steps to ensure that highest quality information is provided without any commercial motivation or bias.

  4. National Survey of Patients’ Bill of Rights Statutes

    PubMed Central

    Jacob, Dan M.; Hochhauser, Mark; Parker, Ruth M.

    2009-01-01

    BACKGROUND Despite vigorous national debate between 1999–2001 the federal patients’ bill of rights (PBOR) was not enacted. However, states have enacted legislation and the Joint Commission defined an accreditation standard to present patients with their rights. Because such initiatives can be undermined by overly complex language, we surveyed the readability of hospital PBOR documents as well as texts mandated by state law. METHODS State Web sites and codes were searched to identify PBOR statutes for general patient populations. The rights addressed were compared with the 12 themes presented in the American Hospital Association’s (AHA) PBOR text of 2002. In addition, we obtained PBOR texts from a sample of hospitals in each state. Readability was evaluated using Prose, a software program which reports an average of eight readability formulas. RESULTS Of 23 states with a PBOR statute for the general public, all establish a grievance policy, four protect a private right of action, and one stipulates fines for violations. These laws address an average of 7.4 of the 12 AHA themes. Nine states’ statutes specify PBOR text for distribution to patients. These documents have an average readability of 15th grade (range, 11.6, New York, to 17.0, Minnesota). PBOR documents from 240 US hospitals have an average readability of 14th grade (range, 8.2 to 17.0). CONCLUSIONS While the average U.S. adult reads at an 8th grade reading level, an advanced college reading level is routinely required to read PBOR documents. Patients are not likely to learn about their rights from documents they cannot read. PMID:19189192

  5. A Zeus++ Code Tool, a Method for Implementing Same, and Storage Medium Storing Computer Readable Instructions for Instantiating the Zeus++ Code Tool

    DTIC Science & Technology

    1999-12-01

    applications, it should be understood that the invention is not limited thereto. Those having - 9 - Navy Case No. 79694 ordinary skill in the art and access...processing. It should also be mentioned that Tecplot is a commercial plotting software package produced by Amtec Engineering, Inc. The following...conditions) 7. Ch (base on edge conditions) -43- 10 Navy Case No. 79694 8. Ch (base on reference conditions) 9 . Momentum thickness 10. Displacement

  6. Method of modifying a volume mesh using sheet insertion

    DOEpatents

    Borden, Michael J [Albuquerque, NM; Shepherd, Jason F [Albuquerque, NM

    2006-08-29

    A method and machine-readable medium provide a technique to modify a hexahedral finite element volume mesh using dual generation and sheet insertion. After generating a dual of a volume stack (mesh), a predetermined algorithm may be followed to modify (refine) the volume mesh of hexahedral elements. The predetermined algorithm may include the steps of locating a sheet of hexahedral mesh elements, determining a plurality of hexahedral elements within the sheet to refine, shrinking the plurality of elements, and inserting a new sheet of hexahedral elements adjacently to modify the volume mesh. Additionally, another predetermined algorithm using mesh cutting may be followed to modify a volume mesh.

  7. Constructing post-surgical discharge instructions through a Delphi consensus methodology.

    PubMed

    Scott, Aaron R; Sanderson, Cody J; Rush, Augustus J; Alore, Elizabeth A; Naik, Aanand D; Berger, David H; Suliburk, James W

    2018-05-01

    Patient education materials are a crucial part of physician-patient communication. We hypothesize that available discharge instructions are difficult to read and fail to address necessary topics. Our objective is to evaluate readability and content of surgical discharge instructions using thyroidectomy to develop standardized discharge materials. Thyroidectomy discharge materials were analyzed for readability and assessed for content. Fifteen endocrine surgeons participated in a modified Delphi consensus panel to select necessary topics. Using readability best practices, we created standardized discharge instructions which included all selected topics. The panel evaluated 40 topics, selected 23, deemed 4 inappropriate, consolidated 5, and did not reach consensus on 8 topics after 4 rounds. The evaluated instructions' reading levels ranged from grade 6.5 to 13.2; none contained all consensus topics. Current post surgical thyroidectomy discharge instructions are more difficult to read than recommended by literacy standards and omit consensus warning signs of major complications. Our easy-to-read discharge instructions cover pertinent topics and may enhance patient education. Delphi methodology is useful for developing post-surgical instructions. Patient education materials need appropriate readability levels and content. We recommend the Delphi method to select content using consensus expert opinion whenever higher level data is lacking. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A new free and open source tool for space plasma modeling.

    NASA Astrophysics Data System (ADS)

    Honkonen, I. J.

    2014-12-01

    I will present a new distributed memory parallel, free and open source computational model for studying space plasma. The model is written in C++ with emphasis on good software development practices and code readability without sacrificing serial or parallel performance. As such the model could be especially useful for education, for learning both (magneto)hydrodynamics (MHD) and computational model development. By using latest features of the C++ standard (2011) it has been possible to develop a very modular program which improves not only the readability of code but also the testability of the model and decreases the effort required to make changes to various parts of the program. Major parts of the model, functionality not directly related to (M)HD, have been outsourced to other freely available libraries which has reduced the development time of the model significantly. I will present an overview of the code architecture as well as details of different parts of the model and will show examples of using the model including preparing input files and plotting results. A multitude of 1-, 2- and 3-dimensional test cases are included in the software distribution and the results of, for example, Kelvin-Helmholtz, bow shock, blast wave and reconnection tests, will be presented.

  9. Interactive QR code beautification with full background image embedding

    NASA Astrophysics Data System (ADS)

    Lin, Lijian; Wu, Song; Liu, Sijiang; Jiang, Bo

    2017-06-01

    QR (Quick Response) code is a kind of two dimensional barcode that was first developed in automotive industry. Nowadays, QR code has been widely used in commercial applications like product promotion, mobile payment, product information management, etc. Traditional QR codes in accordance with the international standard are reliable and fast to decode, but are lack of aesthetic appearance to demonstrate visual information to customers. In this work, we present a novel interactive method to generate aesthetic QR code. By given information to be encoded and an image to be decorated as full QR code background, our method accepts interactive user's strokes as hints to remove undesired parts of QR code modules based on the support of QR code error correction mechanism and background color thresholds. Compared to previous approaches, our method follows the intention of the QR code designer, thus can achieve more user pleasant result, while keeping high machine readability.

  10. Third Molars on the Internet: A Guide for Assessing Information Quality and Readability

    PubMed Central

    Brennan, David; Sambrook, Paul; Armfield, Jason

    2015-01-01

    Background Directing patients suffering from third molars (TMs) problems to high-quality online information is not only medically important, but also could enable better engagement in shared decision making. Objectives This study aimed to develop a scale that measures the scientific information quality (SIQ) for online information concerning wisdom tooth problems and to conduct a quality evaluation for online TMs resources. In addition, the study evaluated whether a specific piece of readability software (Readability Studio Professional 2012) might be reliable in measuring information comprehension, and explored predictors for the SIQ Scale. Methods A cross-sectional sample of websites was retrieved using certain keywords and phrases such as “impacted wisdom tooth problems” using 3 popular search engines. The retrieved websites (n=150) were filtered. The retained 50 websites were evaluated to assess their characteristics, usability, accessibility, trust, readability, SIQ, and their credibility using DISCERN and Health on the Net Code (HoNCode). Results Websites’ mean scale scores varied significantly across website affiliation groups such as governmental, commercial, and treatment provider bodies. The SIQ Scale had a good internal consistency (alpha=.85) and was significantly correlated with DISCERN (r=.82, P<.01) and HoNCode (r=.38, P<.01). Less than 25% of websites had SIQ scores above 75%. The mean readability grade (10.3, SD 1.9) was above the recommended level, and was significantly correlated with the Scientific Information Comprehension Scale (r=.45. P<.01), which provides evidence for convergent validity. Website affiliation and DISCERN were significantly associated with SIQ (P<.01) and explained 76% of the SIQ variance. Conclusion The developed SIQ Scale was found to demonstrate reliability and initial validity. Website affiliation, DISCERN, and HoNCode were significant predictors for the quality of scientific information. The Readability Studio software estimates were associated with scientific information comprehensiveness measures. PMID:26443470

  11. Method of generating a surface mesh

    DOEpatents

    Shepherd, Jason F [Albuquerque, NM; Benzley, Steven [Provo, UT; Grover, Benjamin T [Tracy, CA

    2008-03-04

    A method and machine-readable medium provide a technique to generate and modify a quadrilateral finite element surface mesh using dual creation and modification. After generating a dual of a surface (mesh), a predetermined algorithm may be followed to generate and modify a surface mesh of quadrilateral elements. The predetermined algorithm may include the steps of generating two-dimensional cell regions in dual space, determining existing nodes in primal space, generating new nodes in the dual space, and connecting nodes to form the quadrilateral elements (faces) for the generated and modifiable surface mesh.

  12. 26 CFR 1.197-2 - Amortization of goodwill and certain other intangibles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., process, design, pattern, know-how, format, package design, computer software (as defined in paragraph (c... agreement that provides one of the parties to the agreement with the right to distribute, sell, or provide... any program or routine (that is, any sequence of machine-readable code) that is designed to cause a...

  13. Industrial Arts Technology Bibliography; An Annotated Reference for Librarians.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.

    This compilation is designed to assist librarians in selecting books for supplementing the expanding program of industrial arts education. The books were selected for the major subject areas of a broad industrial arts program, on the basis of reflected interest of students, content, format, and readability. The format and coding used in the…

  14. BioPCD - A Language for GUI Development Requiring a Minimal Skill Set.

    PubMed

    Alvare, Graham Gm; Roche-Lima, Abiel; Fristensky, Brian

    2012-11-01

    BioPCD is a new language whose purpose is to simplify the creation of Graphical User Interfaces (GUIs) by biologists with minimal programming skills. The first step in developing BioPCD was to create a minimal superset of the language referred to as PCD (Pythonesque Command Description). PCD defines the core of terminals and high-level nonterminals required to describe data of almost any type. BioPCD adds to PCD the constructs necessary to describe GUI components and the syntax for executing system commands. BioPCD is implemented using JavaCC to convert the grammar into code. BioPCD is designed to be terse and readable and simple enough to be learned by copying and modifying existing BioPCD files. We demonstrate that BioPCD can easily be used to generate GUIs for existing command line programs. Although BioPCD was designed to make it easier to run bioinformatics programs, it could be used in any domain in which many useful command line programs exist that do not have GUI interfaces.

  15. Readability: Blind Faith in Numbers?

    ERIC Educational Resources Information Center

    McConnell, Campbell

    1983-01-01

    The Flesch reading formula is questioned as being appropriate for evaluating college economics textbooks. The Dale-Chall, Modified Dale-Chall, Fry, and Flesch formulas were used to evaluate nine introductory textbooks. There was little or no consistency in either the absolute reading levels or the rank orderings. (Author/AM)

  16. SAS FORMATS: USES AND ABUSES

    EPA Science Inventory

    SAS formats are a very powerful tool. They allow you to display the data in a more readable manner without modifying the data. They can also be used to group data into categories for use in various procedures like PROC FREQ, PROC TTEST, and PROC MEANS (as a class variable). ...

  17. SAS FORMATS: USES AND ABUSES

    EPA Science Inventory

    SAS formats are a very powerful tool. They allow you to display the data in a more readable manner without modifying it. Formats can also be used to group data into categories for use in various procedures like PROC FREQ, PROC TTEST, and PROC MEANS (as a class variable). As ...

  18. Analysis of readability and quality of web pages addressing both common and uncommon topics in pediatric surgery.

    PubMed

    Adorisio, Ottavio; Silveri, Massimiliano; Rivosecchi, Massimo; Tozzi, Alberto Eugenio; Scottoni, Federico; Buonuomo, Paola Sabrina

    2012-06-01

    The quality medical information on Internet is highly variable. The aim of this study is to determine if Web pages addressing four common pediatric surgical topics (CT) and four uncommon pediatric surgical topics (UT) differ significantly in terms of quality and/or characteristics. We performed an Internet search regarding four CT, addressing more frequent clinical conditions with an incidence≤1:1.500 children (inguinal hernia, varicocele, umbilical hernia, and phimosis) and four UT addressing less frequent clinical conditions with an incidence≥1:1.500 children (anorectal malformation, intestinal atresia, gastroschisis, and omphalocele), using a popular search engine (Google). We evaluated readability with the Flesch reading ease (FRE) and the Flesch-Kincaid grade (FKG) and quality of content using the site checker of the HON Code of Conduct (HON code) for each website. In this study, 30/40 websites addressing CT versus 33/50 addressing UT responded to our criteria. No differences statistically significant in advertisements between the two groups were found (15 vs. 16%) (p>0.05). No differences were found in terms of time from last update, owner/author type, financial disclosure, accreditation, or advertising. CT had higher quality level according to the HON code (6.54±1.38 vs. 5.05±1.82) (p<0.05). Mean FRE was 47.38±14.27 versus 46.24±14.56, respectively, for CT and UT (p>0.05). The mean FKG was 8.1±1.9 for CT versus 8±1.9 for UT (p>0.05). Websites devoted to pediatric surgical topics have higher readability and quality information for disease diagnosis and natural history. Otherwise, the quality of pediatric surgical information on the Internet is high for CT and UT. A high reading level is required to use these resources. Copyright © 2012 by Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. [Trial of eye drops recognizer for visually disabled persons].

    PubMed

    Okamoto, Norio; Suzuki, Katsuhiko; Mimura, Osamu

    2009-01-01

    The development of a device to enable the visually disabled to differentiate eye drops and their dose. The new instrument is composed of a voice generator and a two-dimensional bar-code reader (LS9208). We designed voice outputs for the visually disabled to state when (number of times) and where (right, left, or both) to administer eye drops. We then determined the minimum bar-code size that can be recognized. After attaching bar-codes of the appropriate size to the lateral or bottom surface of the eye drops container, the readability of the bar-codes was compared. The minimum discrimination bar-code size was 6 mm high x 8.5 mm long. Bar-codes on the bottom surface could be more easily recognized than bar-codes on the side. Our newly-developed device using bar-codes enables visually disabled persons to differentiate eye drops and their doses.

  20. Internet-Based Resources Frequently Provide Inaccurate and Out-of-Date Recommendations on Preoperative Fasting: A Systematic Review.

    PubMed

    Roughead, Taren; Sewell, Darreul; Ryerson, Christopher J; Fisher, Jolene H; Flexman, Alana M

    2016-12-01

    Preoperative fasting is important to avoid morbidity and surgery delays, yet recommendations available on the Internet may be inaccurate. Our objectives were to describe the characteristics and recommendations of Internet resources on preoperative fasting and assess the quality and readability of these websites. We searched the Internet for common search terms on preoperative fasting using Google® search engines from 4 English-speaking countries (Canada, the United States, Australia, and the United Kingdom). We screened the first 30 websites from each search and extracted data from unique websites that provided recommendations on preoperative fasting. Website quality was assessed using validated tools (JAMA Benchmark criteria, DISCERN score, and Health on the Net Foundation code [HONcode] certification). Readability was scored using the Flesch Reading Ease score and Flesch-Kincaid Grade Level. A total of 87 websites were included in the analysis. A total of 48 websites (55%) provided at least 1 recommendation that contradicted established guidelines. Websites from health care institutions were most likely to make inaccurate recommendations (61%). Only 17% of websites encouraged preoperative hydration. Quality and readability were poor, with a median JAMA Benchmark score of 1 (interquartile range 0-3), mean DISCERN score 39.8 (SD 12.5), mean reading ease score 49 (SD 15), and mean grade level of 10.6 (SD 2.7). HONcode certification was infrequent (10%). Anesthesia society websites and scientific articles had higher DISCERN scores but worse readability compared with websites from health care institutions. Online fasting recommendations are frequently inconsistent with current guidelines, particularly among health care institution websites. The poor quality and readability of Internet resources on preoperative fasting may confuse patients.

  1. The Gobbledygook in Online Parent-Focused Information about Child and Adolescent Mental Health.

    PubMed

    Wozney, Lori; Radomski, Ashley D; Newton, Amanda S

    2018-06-01

    Online parent-focused informational resources play a vital step in parent decision-making about initiating child and adolescent mental health care, but their usefulness may depend on how easily the resource content can be understood. The purpose of this cross-sectional study was to examine the readability and reliability of parent-focused mental health resources provided on Canadian websites. After meeting inclusion criteria, 50 documents retrieved during the search in September 2016 from websites using online health information searching strategies that would be typically employed by parents underwent analysis. Document readability was assessed using Health Canada recommended instruments: Simple Measure of Gobbledygook (SMOG), Flesch-Kincaid Grade Level, and the Flesch Reading-Ease scale. Reliability was assessed using Health on the Net Foundation Code of Conduct (HONcode). Our analysis revealed that all included documents exceeded the 8th grade reading level. The mean ± SD readability scores were SMOG 11.65 ± 1.10 and FKGL 10.03 ± 1.49. Reading-ease scores showed that 42% (n = 21) of the documents were "Difficult" to read. Factorial ANOVA revealed no significant difference in readability across mental health topic areas or organizational sectors (p = > 0.05). Twenty-four percent of documents came from sites with HONcode certification. Findings suggest that almost all child and adolescent mental health information that would typically be found online by parents in Canada had readability scores that were too high for average parents to read and exceeded Health Canada recommended reading levels. Being able to locate resources online can be significantly precluded if a parent cannot understand and use information to mobilize them to accessing mental health care for their families.

  2. Readability assessment of internet-based patient education materials related to uterine artery embolization.

    PubMed

    Shukla, Pratik; Sanghvi, Saurin P; Lelkes, Valdis M; Kumar, Abhishek; Contractor, Sohail

    2013-04-01

    To determine the readability of Internet-based patient education materials (IPEMs) created by United States hospitals and universities and clinical practices and miscellaneous health care-associated Web sites regarding uterine artery embolization (UAE) as a marker for IPEMs in general. Two hundred unique Web sites were evaluated for patient-related articles on UAE. Web sites produced by US hospitals and universities and clinical practices, as well as miscellaneous health care-associated Web sites meeting the Health on the Net Foundation Code of Conduct criteria were included in the database. By using mathematical regression algorithms based on word and sentence length to quantitatively analyze reading materials for language intricacy, readability of 40 UAE-related IPEMs was assessed with four indices: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (GFOG). Scores were evaluated against national recommendations, and intergroup analysis was performed. None of the IPEMs were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 43.98; FKGL, 10.76; SMOG, 13.63; and GFOG, 14.55. These scores indicate that the readability of UAE IPEMs is written at an advanced level, significantly above the recommended 6th grade reading level (P<.05) determined by the United States Department of Health and Human Services. IPEMs related to UAE generated by hospitals, clinical practices, and miscellaneous health care-associated Web sites are written above the recommended sixth grade level. IPEMs for other disease entities may also reflect similar results. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  3. Comparative analysis of online patient education material pertaining to hepatitis and its complications.

    PubMed

    Gulati, Rishabh; Nawaz, Mohammad; Pyrsopoulos, Nikolaos T

    2016-05-01

    Approximately 50% of patients leave the doctor's office with a poor understanding of their diagnosis. Online patient education websites are becoming a major source of information for many of the patients. Here, we determine the reading grade level of online patient education materials on hepatitis B, hepatitis C, cirrhosis, and hepatocellular cancer and compare it with the National Institutes of Health-recommended reading grade level of sixth to seventh grade or under. A Google search was performed to retrieve patient reading materials. Text was modified to remove medical terms that were defined within the article. Documents were then divided into categories of introduction, risk factors, symptoms, diagnosis, treatment, and prevention. Each document was then analyzed using six validated readability tests to determine the grade level and complexity on the basis of the number of words, syllables, or number of uncommon words. Modified documents had a mean readability score of 10.23, although the recommended score is less than 7.0. Cirrhosis had the highest reading grade level, with a median of 11.3, whereas hepatitis B and hepatocellular carcinoma had the easiest readability, with a median of 9.5. Furthermore, treatment subsection was the most difficult, with a median score of 10.8. Patient reading materials reviewed in this study were written well above the recommended reading grade level. These findings suggest review of patient education materials in an effort to close the gap between the average reading level and the reading materials.

  4. Accuracy and readability of cardiovascular entries on Wikipedia: are they reliable learning resources for medical students?

    PubMed

    Azer, Samy A; AlSwaidan, Nourah M; Alshwairikh, Lama A; AlShammari, Jumana M

    2015-10-06

    To evaluate accuracy of content and readability level of English Wikipedia articles on cardiovascular diseases, using quality and readability tools. Wikipedia was searched on the 6 October 2013 for articles on cardiovascular diseases. Using a modified DISCERN (DISCERN is an instrument widely used in assessing online resources), articles were independently scored by three assessors. The readability was calculated using Flesch-Kincaid Grade Level. The inter-rater agreement between evaluators was calculated using the Fleiss κ scale. This study was based on 47 English Wikipedia entries on cardiovascular diseases. The DISCERN scores had a median=33 (IQR=6). Four articles (8.5%) were of good quality (DISCERN score 40-50), 39 (83%) moderate (DISCERN 30-39) and 4 (8.5%) were poor (DISCERN 10-29). Although the entries covered the aetiology and the clinical picture, there were deficiencies in the pathophysiology of diseases, signs and symptoms, diagnostic approaches and treatment. The number of references varied from 1 to 127 references; 25.9±29.4 (mean±SD). Several problems were identified in the list of references and citations made in the articles. The readability of articles was 14.3±1.7 (mean±SD); consistent with the readability level for college students. In comparison, Harrison's Principles of Internal Medicine 18th edition had more tables, less references and no significant difference in number of graphs, images, illustrations or readability level. The overall agreement between the evaluators was good (Fleiss κ 0.718 (95% CI 0.57 to 0.83). The Wikipedia entries are not aimed at a medical audience and should not be used as a substitute to recommended medical resources. Course designers and students should be aware that Wikipedia entries on cardiovascular diseases lack accuracy, predominantly due to errors of omission. Further improvement of the Wikipedia content of cardiovascular entries would be needed before they could be considered a supplementary resource. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. SAS FORMATS: USES AND ABUSES

    EPA Science Inventory

    SAS formats are a very powerful tool. They allow you to display the data in a more readable manner without modifying it. Formats can also be used to group data into categories for use in various procedures like PROC FREQ, PROC TTEST, and PROC MEANS (as a class variable). As w...

  6. 2015 Workplace and Gender Relations Survey of Reserve Component Members. Overview Report (2015 WGRR)

    DTIC Science & Technology

    2016-03-01

    to gauge readability, reliability, and distress of the items. The survey was modified based on results from the pretest . Further information on ...of the items. The survey was modified based on results from the pretest . Further information on the pretest can be found in RAND’s report (Morral...based on the gender of the military member). The SEQ-DoD was designed to gather information on perceived experiences of these behaviors rather than

  7. 26 CFR 1.197-2 - Amortization of goodwill and certain other intangibles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., process, design, pattern, know-how, format, package design, computer software (as defined in paragraph (c... section 1253(b)(1) and includes any agreement that provides one of the parties to the agreement with the... any program or routine (that is, any sequence of machine-readable code) that is designed to cause a...

  8. 26 CFR 1.197-2 - Amortization of goodwill and certain other intangibles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., process, design, pattern, know-how, format, package design, computer software (as defined in paragraph (c... has the meaning given in section 1253(b)(1) and includes any agreement that provides one of the...-readable code) that is designed to cause a computer to perform a desired function or set of functions, and...

  9. 26 CFR 1.197-2 - Amortization of goodwill and certain other intangibles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., process, design, pattern, know-how, format, package design, computer software (as defined in paragraph (c... has the meaning given in section 1253(b)(1) and includes any agreement that provides one of the...-readable code) that is designed to cause a computer to perform a desired function or set of functions, and...

  10. An Evaluation of Implementing Koha in a Chinese Language Environment

    ERIC Educational Resources Information Center

    Chang, Naicheng; Tsai, Yuchin; Hopkinson, Alan

    2010-01-01

    Purpose: The purpose of this paper is to evaluate issues of different scripts in the same record (in MARC21 and Chinese machine-readable cataloguing (CMARC)) and Chinese internal codes (i.e. double-byte character set) when implementing Koha. It also discusses successful efforts in promoting the adoption of Koha in Taiwan, particularly the…

  11. Translating an AI application from Lisp to Ada: A case study

    NASA Technical Reports Server (NTRS)

    Davis, Gloria J.

    1991-01-01

    A set of benchmarks was developed to test the performance of a newly designed computer executing both Lisp and Ada. Among these was AutoClassII -- a large Artificial Intelligence (AI) application written in Common Lisp. The extraction of a representative subset of this complex application was aided by a Lisp Code Analyzer (LCA). The LCA enabled rapid analysis of the code, putting it in a concise and functionally readable form. An equivalent benchmark was created in Ada through manual translation of the Lisp version. A comparison of the execution results of both programs across a variety of compiler-machine combinations indicate that line-by-line translation coupled with analysis of the initial code can produce relatively efficient and reusable target code.

  12. Convergence Toward Common Standards in Machine-Readable Cataloging *

    PubMed Central

    Gull, C. D.

    1969-01-01

    The adoption of the MARC II format for the communication of bibliographic information by the three National Libraries of the U.S.A. makes it possible for those libraries to converge on the remaining necessary common standards for machine-readable cataloging. Three levels of standards are identified: fundamental, the character set; intermediate, MARC II; and detailed, the codes for identifying data elements. The convergence on these standards implies that the National Libraries can create and operate a Joint Bibliographic Data Bank requiring standard book numbers and universal serial numbers for identifying monographs and serials and that the system will thoroughly process contributed catalog entries before adding them to the Data Bank. There is reason to hope that the use of the MARC II format will facilitate catalogers' decision processes. PMID:5782261

  13. Field‐readable alphanumeric flags are valuable markers for shorebirds: use of double‐marking to identify cases of misidentification

    USGS Publications Warehouse

    Roche, Erin A.; Dovichin, Colin M.; Arnold, Todd W.

    2014-01-01

    Implicit assumptions for most mark-recapture studies are that individuals do not lose their markers and all observed markers are correctly recorded. If these assumptions are violated, e.g., due to loss or extreme wear of markers, estimates of population size and vital rates will be biased. Double-marking experiments have been widely used to estimate rates of marker loss and adjust for associated bias, and we extended this approach to estimate rates of recording errors. We double-marked 309 Piping Plovers (Charadrius melodus) with unique combinations of color bands and alphanumeric flags and used multi-state mark recapture models to estimate the frequency with which plovers were misidentified. Observers were twice as likely to read and report an invalid color-band combination (2.4% of the time) as an invalid alphanumeric code (1.0%). Observers failed to read matching band combinations or alphanumeric flag codes 4.5% of the time. Unlike previous band resighting studies, use of two resightable markers allowed us to identify when resighting errors resulted in reports of combinations or codes that were valid, but still incorrect; our results suggest this may be a largely unappreciated problem in mark-resight studies. Field-readable alphanumeric flags offer a promising auxiliary marker for identifying and potentially adjusting for false-positive resighting errors that may otherwise bias demographic estimates.

  14. Advance Prediction of Difficulty with C-Tests.

    ERIC Educational Resources Information Center

    Klein-Braley, Christine

    This report investigates the selection of appropriate texts for C-Tests, a modified form of the cloze test, for assessing second language learning. The procedure for textbook readability first involved the administration of different texts to sample groups to determine the C-test difficulty of individual texts. At the same time, a variety of…

  15. 37 CFR 1.824 - Form and format for nucleotide and/or amino acid sequence submissions in computer readable form.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Form and format for... And/or Amino Acid Sequences § 1.824 Form and format for nucleotide and/or amino acid sequence... Code for Information Interchange (ASCII) text. No other formats shall be allowed. (3) The computer...

  16. USL/DBMS NASA/PC R and D project C programming standards

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

  17. A comparison of different methods to implement higher order derivatives of density functionals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van Dam, Hubertus J.J.

    Density functional theory is the dominant approach in electronic structure methods today. To calculate properties higher order derivatives of the density functionals are required. These derivatives might be implemented manually,by automatic differentiation, or by symbolic algebra programs. Different authors have cited different reasons for using the particular method of their choice. This paper presents work where all three approaches were used and the strengths and weaknesses of each approach are considered. It is found that all three methods produce code that is suffficiently performanted for practical applications, despite the fact that our symbolic algebra generated code and our automatic differentiationmore » code still have scope for significant optimization. The automatic differentiation approach is the best option for producing readable and maintainable code.« less

  18. Is Wikipedia a Reliable Learning Resource for Medical Students? Evaluating Respiratory Topics

    ERIC Educational Resources Information Center

    Azer, Samy A.

    2015-01-01

    The aim of the present study was to critically evaluate the accuracy and readability of English Wikipedia articles on the respiratory system and its disorders and whether they can be a suitable resource for medical students. On April 27, 2014, English Wikipedia was searched for articles on respiratory topics. Using a modified DISCERN instrument,…

  19. Quality and readability of online patient information regarding sclerotherapy for venous malformations.

    PubMed

    Pass, Jonathan H; Patel, Amani H; Stuart, Sam; Barnacle, Alex M; Patel, Premal A

    2018-05-01

    Patients often use the internet as a source of information about their condition and treatments. However, this information is unregulated and varies in quality. To evaluate the readability and quality of online information for pediatric and adult patients and caregivers regarding sclerotherapy for venous malformations. "Venous malformation sclerotherapy" was entered into Google, and results were reviewed until 20 sites that satisfied predefined inclusion criteria were identified. Scientific and non-patient-focused web pages were excluded. Readability was assessed using the Flesch Reading Ease Score and American Medical Association reading difficulty recommendations and quality was assessed using Journal of the American Medical Association standards and assessing if the site displayed HONcode (Health on the Net Code) certification. Assessment of the breadth of relevant information was made using a predefined checklist. Forty-nine search engine results were reviewed before 20 sites were identified for analysis. Average Flesch Reading Ease Score was 44 (range: 24.2-70.1), representing a "fairly difficult" reading level. None of the sites had a Flesch Reading Ease Score meeting the American Medical Association recommendation of 80-90. Only one site met all four Journal of the American Medical Association quality criteria (average: 2.1). None of the sites displayed a HONcode seal. The information most frequently found was: sclerotherapy is performed by radiologists, multiple treatments may be needed and surgery is an alternative treatment. Online information regarding sclerotherapy for venous malformations is heterogeneous in quality and breadth of information, and does not meet readability recommendations for patient information. Radiologists should be aware of and account for this when meeting patients.

  20. BioPCD - A Language for GUI Development Requiring a Minimal Skill Set

    PubMed Central

    Alvare, Graham GM; Roche-Lima, Abiel; Fristensky, Brian

    2016-01-01

    BioPCD is a new language whose purpose is to simplify the creation of Graphical User Interfaces (GUIs) by biologists with minimal programming skills. The first step in developing BioPCD was to create a minimal superset of the language referred to as PCD (Pythonesque Command Description). PCD defines the core of terminals and high-level nonterminals required to describe data of almost any type. BioPCD adds to PCD the constructs necessary to describe GUI components and the syntax for executing system commands. BioPCD is implemented using JavaCC to convert the grammar into code. BioPCD is designed to be terse and readable and simple enough to be learned by copying and modifying existing BioPCD files. We demonstrate that BioPCD can easily be used to generate GUIs for existing command line programs. Although BioPCD was designed to make it easier to run bioinformatics programs, it could be used in any domain in which many useful command line programs exist that do not have GUI interfaces. PMID:27818582

  1. Readability versus Leveling.

    ERIC Educational Resources Information Center

    Fry, Edward

    2002-01-01

    Shows some similarities and differences between readability formulas and leveling procedures and reports some current large-scale uses of readability formulas. Presents a dictionary definition of readability and leveling, and a history and background of readability and leveling. Discusses what goes into determining readability and leveling scores.…

  2. The IHMC CmapTools software in research and education: a multi-level use case in Space Meteorology

    NASA Astrophysics Data System (ADS)

    Messerotti, Mauro

    2010-05-01

    The IHMC (Institute for Human and Machine Cognition, Florida University System, USA) CmapTools software is a powerful multi-platform tool for knowledge modelling in graphical form based on concept maps. In this work we present its application for the high-level development of a set of multi-level concept maps in the framework of Space Meteorology to act as the kernel of a space meteorology domain ontology. This is an example of a research use case, as a domain ontology coded in machine-readable form via e.g. OWL (Web Ontology Language) is suitable to be an active layer of any knowledge management system embedded in a Virtual Observatory (VO). Apart from being manageable at machine level, concept maps developed via CmapTools are intrinsically human-readable and can embed hyperlinks and objects of many kinds. Therefore they are suitable to be published on the web: the coded knowledge can be exploited for educational purposes by the students and the public, as the level of information can be naturally organized among linked concept maps in progressively increasing complexity levels. Hence CmapTools and its advanced version COE (Concept-map Ontology Editor) represent effective and user-friendly software tools for high-level knowledge represention in research and education.

  3. A Barcoding Strategy Enabling Higher-Throughput Library Screening by Microscopy.

    PubMed

    Chen, Robert; Rishi, Harneet S; Potapov, Vladimir; Yamada, Masaki R; Yeh, Vincent J; Chow, Thomas; Cheung, Celia L; Jones, Austin T; Johnson, Terry D; Keating, Amy E; DeLoache, William C; Dueber, John E

    2015-11-20

    Dramatic progress has been made in the design and build phases of the design-build-test cycle for engineering cells. However, the test phase usually limits throughput, as many outputs of interest are not amenable to rapid analytical measurements. For example, phenotypes such as motility, morphology, and subcellular localization can be readily measured by microscopy, but analysis of these phenotypes is notoriously slow. To increase throughput, we developed microscopy-readable barcodes (MiCodes) composed of fluorescent proteins targeted to discernible organelles. In this system, a unique barcode can be genetically linked to each library member, making possible the parallel analysis of phenotypes of interest via microscopy. As a first demonstration, we MiCoded a set of synthetic coiled-coil leucine zipper proteins to allow an 8 × 8 matrix to be tested for specific interactions in micrographs consisting of mixed populations of cells. A novel microscopy-readable two-hybrid fluorescence localization assay for probing candidate interactions in the cytosol was also developed using a bait protein targeted to the peroxisome and a prey protein tagged with a fluorescent protein. This work introduces a generalizable, scalable platform for making microscopy amenable to higher-throughput library screening experiments, thereby coupling the power of imaging with the utility of combinatorial search paradigms.

  4. GOAL - A test engineer oriented language. [Ground Operations Aerospace Language for coding automatic test

    NASA Technical Reports Server (NTRS)

    Mitchell, T. R.

    1974-01-01

    The development of a test engineer oriented language has been under way at the Kennedy Space Center for several years. The result of this effort is the Ground Operations Aerospace Language, GOAL, a self-documenting, high-order language suitable for coding automatic test, checkout and launch procedures. GOAL is a highly readable, writable, retainable language that is easily learned by nonprogramming oriented engineers. It is sufficiently powerful for use at all levels of Space Shuttle ground processing, from line replaceable unit checkout to integrated launch day operations. This paper will relate the language development, and describe GOAL and its applications.

  5. The readability of American Academy of Pediatrics patient education brochures.

    PubMed

    Freda, Margaret Comerford

    2005-01-01

    The purpose of this study was to evaluate the readability of American Academy of Pediatrics (AAP) patient education brochures. Seventy-four brochures were analyzed using two readability formulas. Mean readability for all 74 brochures was grade 7.94 using the Flesch-Kincaid formula, and grade 10.1 with SMOG formula (P = .001). Using the SMOG formula, no brochures were of acceptably low (< or =8th grade) readability levels (range 8.3 to 12.7). Using the Flesch-Kincaid formula, 41 of the 74 had acceptable readability levels (< or =8th grade). The SMOG formula routinely assessed brochures 2 to 3 grade levels higher than did the Flesch-Kincaid formula. Some AAP patient education brochures have acceptably low levels of readability, but at least half are written at higher than acceptable readability levels for the general public. This study also demonstrated statistically significant variability between the two different readability formulas; had only the SMOG formula been used, all of the brochures would have had unacceptably high readability levels. Readability is an essential concept for patient education materials. Professional associations that develop and market patient education materials should test for readability and publish those readability levels on each piece of patient education so health care providers will know if the materials are appropriate for their patients.

  6. Evaluation of the readability of ACOG patient education pamphlets. The American College of Obstetricians and Gynecologists.

    PubMed

    Freda, M C; Damus, K; Merkatz, I R

    1999-05-01

    To evaluate whether ACOG's patient education pamphlets comply with the recommended readability level for health education materials intended for the general public. All 100 English-language pamphlets available during 1997 (created or revised between 1988 and 1997) were evaluated using four standard readability formulas. Mean readability levels of ACOG's pamphlets were between grade 7.0 to grade 9.3, depending on the formula used. Analysis of readability over the 10 years showed a trend toward lower readability levels. Analysis by category of pamphlet found that the lowest readability levels were in "Especially for teens" pamphlets. Our data suggested that most of ACOG's patient education pamphlets currently available are written at a higher readability level than recommended for the general public. The readability of those pamphlets improved in the 10 years since the organization published its first pamphlet, but the goal of sixth-grade readability level has not been reached.

  7. An alpha-numeric code for representing N-linked glycan structures in secreted glycoproteins.

    PubMed

    Yusufi, Faraaz Noor Khan; Park, Wonjun; Lee, May May; Lee, Dong-Yup

    2009-01-01

    Advances in high-throughput techniques have led to the creation of increasing amounts of glycome data. The storage and analysis of this data would benefit greatly from a compact notation for describing glycan structures that can be easily stored and interpreted by computers. Towards this end, we propose a fixed-length alpha-numeric code for representing N-linked glycan structures commonly found in secreted glycoproteins from mammalian cell cultures. This code, GlycoDigit, employs a pre-assigned alpha-numeric index to represent the monosaccharides attached in different branches to the core glycan structure. The present branch-centric representation allows us to visualize the structure while the numerical nature of the code makes it machine readable. In addition, a difference operator can be defined to quantitatively differentiate between glycan structures for further analysis. The usefulness and applicability of GlycoDigit were demonstrated by constructing and visualizing an N-linked glycosylation network.

  8. Dynamic wavefront creation for processing units using a hybrid compactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puthoor, Sooraj; Beckmann, Bradford M.; Yudanov, Dmitri

    A method, a non-transitory computer readable medium, and a processor for repacking dynamic wavefronts during program code execution on a processing unit, each dynamic wavefront including multiple threads are presented. If a branch instruction is detected, a determination is made whether all wavefronts following a same control path in the program code have reached a compaction point, which is the branch instruction. If no branch instruction is detected in executing the program code, a determination is made whether all wavefronts following the same control path have reached a reconvergence point, which is a beginning of a program code segment tomore » be executed by both a taken branch and a not taken branch from a previous branch instruction. The dynamic wavefronts are repacked with all threads that follow the same control path, if all wavefronts following the same control path have reached the branch instruction or the reconvergence point.« less

  9. The Readability of an Unreadable Text.

    ERIC Educational Resources Information Center

    Gordon, Robert M.

    1980-01-01

    The Dale-Chall Readability Formula and the Fry Readability Graph were used to analyze passages of Plato's "Parmenides," a notoriously difficult literary piece. The readability levels of the text ranged from fourth to eighth grade (Dale-Chall) and from sixth to tenth grade (Fry), indicating the limitations of the readability tests. (DF)

  10. Is Wikipedia a reliable learning resource for medical students? Evaluating respiratory topics.

    PubMed

    Azer, Samy A

    2015-03-01

    The aim of the present study was to critically evaluate the accuracy and readability of English Wikipedia articles on the respiratory system and its disorders and whether they can be a suitable resource for medical students. On April 27, 2014, English Wikipedia was searched for articles on respiratory topics. Using a modified DISCERN instrument, articles were independently scored by three assessors. The scoring targeted content accuracy, frequency of updating, and quality of references. The readability of articles was measured using two other instruments. The mean DISCERN score for the 40 articles identified was 26.4±6.3. Most articles covered causes, signs and symptoms, prevention, and treatment. However, several knowledge deficiencies in the pathogenesis of diseases, investigations needed, and treatment were observed. The total number of references for the 40 articles was 1,654, and the references varied from 0 to 168 references, but several problems were identified in the list of references and citations made. The readability of articles was in the range of 9.4±1.8 to 22.6±10.7 using the Flesch-Kincaid Grade Level instrument and 10.0±2.6 to 19.6±8.3 using the Readability Coleman-Liau index. A strong correlation was found between the two instruments (r2=0.744, P<0.001). The agreement between the assessors had mean κ scores in the range of 0.712-0.857. In conclusion, despite the effort placed in creating Wikipedia respiratory articles by anonymous volunteers (wikipedians), most articles had knowledge deficiencies, were not accurate, and were not suitable for medical students as learning resources. Copyright © 2015 The American Physiological Society.

  11. A Manual for Readable Writing.

    ERIC Educational Resources Information Center

    Klare, George R.

    One of the ways to handle the increasing demands on readers' skills is to make writing more readable. The problem has two different aspects: predicting how readable writing will be to a reader, and producing writing that is readable to that reader. Prediction is relatively simple, and can be done statistically with readability formulas. Production…

  12. Readability, content, and quality of online patient education materials on preeclampsia.

    PubMed

    Lange, Elizabeth M S; Shah, Anuj M; Braithwaite, Brian A; You, Whitney B; Wong, Cynthia A; Grobman, William A; Toledo, Paloma

    2015-01-01

    The objective of this study was to evaluate the readability, content, and quality of patient education materials addressing preeclampsia. Websites of U.S. obstetrics and gynecology residency programs were searched for patient education materials. Readability, content, and quality were assessed. A one-sample t-test was used to evaluate mean readability level compared with the recommended 6th grade reading level. Mean readability levels were higher using all indices (p < 0.001). Content was variable with good website understandability, but poor actionability. The mean readability was above the recommended 6th grade reading level. The content, readability, and actionability of preeclampsia patient education materials should be improved.

  13. Epitaxial Growth of Hetero-Ln-MOF Hierarchical Single Crystals for Domain- and Orientation-Controlled Multicolor Luminescence 3D Coding Capability.

    PubMed

    Pan, Mei; Zhu, Yi-Xuan; Wu, Kai; Chen, Ling; Hou, Ya-Jun; Yin, Shao-Yun; Wang, Hai-Ping; Fan, Ya-Nan; Su, Cheng-Yong

    2017-11-13

    Core-shell or striped heteroatomic lanthanide metal-organic framework hierarchical single crystals were obtained by liquid-phase anisotropic epitaxial growth, maintaining identical periodic organization while simultaneously exhibiting spatially segregated structure. Different types of domain and orientation-controlled multicolor photophysical models are presented, which show either visually distinguishable or visible/near infrared (NIR) emissive colors. This provides a new bottom-up strategy toward the design of hierarchical molecular systems, offering high-throughput and multiplexed luminescence color tunability and readability. The unique capability of combining spectroscopic coding with 3D (three-dimensional) microscale spatial coding is established, providing potential applications in anti-counterfeiting, color barcoding, and other types of integrated and miniaturized optoelectronic materials and devices. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The NATO thesaurus project

    NASA Technical Reports Server (NTRS)

    Krueger, Jonathan

    1990-01-01

    This document describes functionality to be developed to support the NATO technical thesaurus. Described are the specificity of the thesaurus structure and function; the distinction between the thesaurus information and its representation in a given online, machine readable, or printed form; the enhancement of the thesaurus with the assignment of COSATI codes (fields and groups) to posting terms, the integration of DTIC DRIT and NASA thesauri related terminology, translation of posting terms into French; and the provision of a basis for system design.

  15. GlycoRDF: an ontology to standardize glycomics data in RDF

    PubMed Central

    Ranzinger, Rene; Aoki-Kinoshita, Kiyoko F.; Campbell, Matthew P.; Kawano, Shin; Lütteke, Thomas; Okuda, Shujiro; Shinmachi, Daisuke; Shikanai, Toshihide; Sawaki, Hiromichi; Toukach, Philip; Matsubara, Masaaki; Yamada, Issaku; Narimatsu, Hisashi

    2015-01-01

    Motivation: Over the last decades several glycomics-based bioinformatics resources and databases have been created and released to the public. Unfortunately, there is no common standard in the representation of the stored information or a common machine-readable interface allowing bioinformatics groups to easily extract and cross-reference the stored information. Results: An international group of bioinformatics experts in the field of glycomics have worked together to create a standard Resource Description Framework (RDF) representation for glycomics data, focused on glycan sequences and related biological source, publications and experimental data. This RDF standard is defined by the GlycoRDF ontology and will be used by database providers to generate common machine-readable exports of the data stored in their databases. Availability and implementation: The ontology, supporting documentation and source code used by database providers to generate standardized RDF are available online (http://www.glycoinfo.org/GlycoRDF/). Contact: rene@ccrc.uga.edu or kkiyoko@soka.ac.jp Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25388145

  16. GlycoRDF: an ontology to standardize glycomics data in RDF.

    PubMed

    Ranzinger, Rene; Aoki-Kinoshita, Kiyoko F; Campbell, Matthew P; Kawano, Shin; Lütteke, Thomas; Okuda, Shujiro; Shinmachi, Daisuke; Shikanai, Toshihide; Sawaki, Hiromichi; Toukach, Philip; Matsubara, Masaaki; Yamada, Issaku; Narimatsu, Hisashi

    2015-03-15

    Over the last decades several glycomics-based bioinformatics resources and databases have been created and released to the public. Unfortunately, there is no common standard in the representation of the stored information or a common machine-readable interface allowing bioinformatics groups to easily extract and cross-reference the stored information. An international group of bioinformatics experts in the field of glycomics have worked together to create a standard Resource Description Framework (RDF) representation for glycomics data, focused on glycan sequences and related biological source, publications and experimental data. This RDF standard is defined by the GlycoRDF ontology and will be used by database providers to generate common machine-readable exports of the data stored in their databases. The ontology, supporting documentation and source code used by database providers to generate standardized RDF are available online (http://www.glycoinfo.org/GlycoRDF/). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. A Machine Learning Approach to Measurement of Text Readability for EFL Learners Using Various Linguistic Features

    ERIC Educational Resources Information Center

    Kotani, Katsunori; Yoshimi, Takehiko; Isahara, Hitoshi

    2011-01-01

    The present paper introduces and evaluates a readability measurement method designed for learners of EFL (English as a foreign language). The proposed readability measurement method (a regression model) estimates the text readability based on linguistic features, such as lexical, syntactic and discourse features. Text readability refers to the…

  18. Instruction manual for UTEP weld gas hydrogen detector

    NASA Technical Reports Server (NTRS)

    Mcclure, John; Pang, Tonghui

    1992-01-01

    The instrument described in this manual was developed at the University of Texas at El Paso under contract from the National Aeronautics and Space Administration Marshall Space Flight Center. The instrument has been used to detect hydrogen in the shielding gas of Variable Polarity Plasma Arc (VPPA) welds at concentrations of less than 100 ppm. The instrument makes measurements in real time during the welding operation and provides the operator with an easily readable graphic display of the present level of hydrogen in the arc as well as the level of hydrogen over the past approximately five minutes. In this way the welder can not only tell if the present level of hydrogen is excessive, but can see what changes in weld parameters have done to the level of hydrogen. The welder can set the level of hydrogen that is considered critical and the instrument display will indicate when that level has been exceeded. All detection is from the torch side. All needed equipment is supplied by the developer except for an IBM PC compatible computer which must be supplied by the user. Source code is supplied in this manual so that the user can modify the control program as desired.

  19. Readability of HIV/AIDS educational materials: the role of the medium of communication, target audience, and producer characteristics.

    PubMed

    Wells, J A

    1994-12-01

    The reading difficulty of many HIV/AIDS brochures and pamphlets limits their effectiveness. This analysis addresses correlates of readability in 136 HIV/AIDS educational items. Readability is measured using the SMOG Index. The medium of communication is significantly related to readability: comic books and brochures are, on average, more readable than books and pamphlets (10.9 versus 11.9). The target audience also differentiates readability. Materials for HIV antibody test seekers, the general community, and sexually active adults have a more difficult reading grade, averaging 12.1, whereas materials for ethnic minorities average a more readable 9.2. The producer organization's type and location are unrelated to readability, but an AIDS-specific organizational focus correlates with better readability (grade 10.8 vs. 11.8). These findings remain significant in multivariate analysis. The results indicate that brochures and comics are more likely to be comprehended by low-literacy populations, that an understanding of the literacy of target audiences is needed to produce materials with appropriate reading levels, and that policies to influence producer organizations may result in the creation of more readable materials.

  20. Optimized scalar promotion with load and splat SIMD instructions

    DOEpatents

    Eichenberger, Alexander E; Gschwind, Michael K; Gunnels, John A

    2013-10-29

    Mechanisms for optimizing scalar code executed on a single instruction multiple data (SIMD) engine are provided. Placement of vector operation-splat operations may be determined based on an identification of scalar and SIMD operations in an original code representation. The original code representation may be modified to insert the vector operation-splat operations based on the determined placement of vector operation-splat operations to generate a first modified code representation. Placement of separate splat operations may be determined based on identification of scalar and SIMD operations in the first modified code representation. The first modified code representation may be modified to insert or delete separate splat operations based on the determined placement of the separate splat operations to generate a second modified code representation. SIMD code may be output based on the second modified code representation for execution by the SIMD engine.

  1. Optimized scalar promotion with load and splat SIMD instructions

    DOEpatents

    Eichenberger, Alexandre E [Chappaqua, NY; Gschwind, Michael K [Chappaqua, NY; Gunnels, John A [Yorktown Heights, NY

    2012-08-28

    Mechanisms for optimizing scalar code executed on a single instruction multiple data (SIMD) engine are provided. Placement of vector operation-splat operations may be determined based on an identification of scalar and SIMD operations in an original code representation. The original code representation may be modified to insert the vector operation-splat operations based on the determined placement of vector operation-splat operations to generate a first modified code representation. Placement of separate splat operations may be determined based on identification of scalar and SIMD operations in the first modified code representation. The first modified code representation may be modified to insert or delete separate splat operations based on the determined placement of the separate splat operations to generate a second modified code representation. SIMD code may be output based on the second modified code representation for execution by the SIMD engine.

  2. Content Analysis of Vomit and Diarrhea Cleanup Procedures To Prevent Norovirus Infections in Retail and Food Service Operations.

    PubMed

    Chao, Morgan G; Dubé, Anne-Julie; Leone, Cortney M; Moore, Christina M; Fraser, Angela M

    2016-11-01

    Human noroviruses are the leading cause of foodborne disease in the United States, sickening 19 to 21 million Americans each year. Vomit and diarrhea are both highly concentrated sources of norovirus particles. For this reason, establishing appropriate cleanup procedures for these two substances is critical. Food service establishments in states that have adopted the 2009 or 2013 U.S. Food and Drug Administration Food Code are required to have a program detailing specific cleanup procedures. The aim of our study was to determine the alignment of existing vomit and diarrhea cleanup procedures with the 11 elements recommended in Annex 3 of the 2011 Supplement to the 2009 Food Code and to determine their readability and clarity of presentation. In July 2015, we located vomit and diarrhea cleanup procedures by asking Norovirus Collaborative for Outreach, Research, and Education stakeholders for procedures used by their constituency groups and by conducting a Google Advanced Search of the World Wide Web. We performed content analysis to determine alignment with the recommendations in Annex 3. Readability and clarity of presentation were also assessed. A total of 38 artifacts were analyzed. The mean alignment score was 7.0 ± 1.7 of 11 points; the mean clarity score was 6.7 ± 2.5 of 17 points. Only nine artifacts were classified as high clarity, high alignment. Vomit and diarrhea cleanup procedures should align with Annex 3 in the Food Code and should, as well, be clearly presented; yet, none of the artifacts completely met both conditions. To reduce the spread of norovirus infections in food service establishments, editable guidelines are needed that are aligned with Annex 3 and are clearly written, into which authors could insert their facility-specific information.

  3. Improving readability of informed consents for research at an academic medical institution.

    PubMed

    Hadden, Kristie B; Prince, Latrina Y; Moore, Tina D; James, Laura P; Holland, Jennifer R; Trudeau, Christopher R

    2017-12-01

    The final rule for the protection of human subjects requires that informed consent be "in language understandable to the subject" and mandates that "the informed consent must be organized in such a way that facilitates comprehension." This study assessed the readability of Institutional Review Board-approved informed consent forms at our institution, implemented an intervention to improve the readability of consent forms, and measured the first year impact of the intervention. Readability assessment was conducted on a sample of 217 Institutional Review Board-approved informed consents from 2013 to 2015. A plain language informed consent template was developed and implemented and readability was assessed again after 1 year. The mean readability of the baseline sample was 10th grade. The mean readability of the post-intervention sample (n=82) was seventh grade. Providing investigators with a plain language informed consent template and training can promote improved readability of informed consents for research.

  4. Readability of Online Health Information: A Meta-Narrative Systematic Review.

    PubMed

    Daraz, Lubna; Morrow, Allison S; Ponce, Oscar J; Farah, Wigdan; Katabi, Abdulrahman; Majzoub, Abdul; Seisa, Mohamed O; Benkhadra, Raed; Alsawas, Mouaz; Larry, Prokop; Murad, M Hassan

    2018-01-01

    Online health information should meet the reading level for the general public (set at sixth-grade level). Readability is a key requirement for information to be helpful and improve quality of care. The authors conducted a systematic review to evaluate the readability of online health information in the United States and Canada. Out of 3743 references, the authors included 157 cross-sectional studies evaluating 7891 websites using 13 readability scales. The mean readability grade level across websites ranged from grade 10 to 15 based on the different scales. Stratification by specialty, health condition, and type of organization producing information revealed the same findings. In conclusion, online health information in the United States and Canada has a readability level that is inappropriate for general public use. Poor readability can lead to misinformation and may have a detrimental effect on health. Efforts are needed to improve readability and the content of online health information.

  5. Determining Readability: How to Select and Apply Easy-to-Use Readability Formulas to Assess the Difficulty of Adult Literacy Materials

    ERIC Educational Resources Information Center

    Burke, Victoria; Greenberg, Daphne

    2010-01-01

    There are many readability tools that instructors can use to help adult learners select reading materials. We describe and compare different types of readability tools: formulas calculated by hand, tools found on the Web, tools embedded in a word processing program, and readability tools found in a commercial software program. Practitioners do not…

  6. Assessing readability formula differences with written health information materials: application, results, and recommendations.

    PubMed

    Wang, Lih-Wern; Miller, Michael J; Schmitt, Michael R; Wen, Frances K

    2013-01-01

    Readability formulas are often used to guide the development and evaluation of literacy-sensitive written health information. However, readability formula results may vary considerably as a result of differences in software processing algorithms and how each formula is applied. These variations complicate interpretations of reading grade level estimates, particularly without a uniform guideline for applying and interpreting readability formulas. This research sought to (1) identify commonly used readability formulas reported in the health care literature, (2) demonstrate the use of the most commonly used readability formulas on written health information, (3) compare and contrast the differences when applying common readability formulas to identical selections of written health information, and (4) provide recommendations for choosing an appropriate readability formula for written health-related materials to optimize their use. A literature search was conducted to identify the most commonly used readability formulas in health care literature. Each of the identified formulas was subsequently applied to word samples from 15 unique examples of written health information about the topic of depression and its treatment. Readability estimates from common readability formulas were compared based on text sample size, selection, formatting, software type, and/or hand calculations. Recommendations for their use were provided. The Flesch-Kincaid formula was most commonly used (57.42%). Readability formulas demonstrated variability up to 5 reading grade levels on the same text. The Simple Measure of Gobbledygook (SMOG) readability formula performed most consistently. Depending on the text sample size, selection, formatting, software, and/or hand calculations, the individual readability formula estimated up to 6 reading grade levels of variability. The SMOG formula appears best suited for health care applications because of its consistency of results, higher level of expected comprehension, use of more recent validation criteria for determining reading grade level estimates, and simplicity of use. To improve interpretation of readability results, reporting reading grade level estimates from any formula should be accompanied with information about word sample size, location of word sampling in the text, formatting, and method of calculation. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. HAL/S - The programming language for Shuttle

    NASA Technical Reports Server (NTRS)

    Martin, F. H.

    1974-01-01

    HAL/S is a higher order language and system, now operational, adopted by NASA for programming Space Shuttle on-board software. Program reliability is enhanced through language clarity and readability, modularity through program structure, and protection of code and data. Salient features of HAL/S include output orientation, automatic checking (with strictly enforced compiler rules), the availability of linear algebra, real-time control, a statement-level simulator, and compiler transferability (for applying HAL/S to additional object and host computers). The compiler is described briefly.

  8. Readability of the Written Study Information in Pediatric Research in France

    PubMed Central

    Ménoni, Véronique; Lucas, Noël; Leforestier, Jean-François; Doz, François; Chatellier, Gilles; Jacqz-Aigain, Evelyne; Giraud, Carole; Tréluyer, Jean-Marc; Chappuy, Hélène

    2011-01-01

    Background The aim was to evaluate the readability of research information leaflets (RIL) for minors asked to participate in biomedical research studies and to assess the factors influencing this readability. Methods and Findings All the pediatric protocols from three French pediatric clinical research units were included (N = 104). Three criteria were used to evaluate readability: length of the text, Flesch's readability score and presence of illustrations. We compared the readability of RIL to texts specifically written for children (school textbooks, school exams or extracts from literary works). We assessed the effect of protocol characteristics on readability. The RIL had a median length of 608 words [350 words, 25th percentile; 1005 words, 75th percentile], corresponding to two pages. The readability of the RIL, with a median Flesch score of 40 [30; 47], was much poorer than that of pediatric reference texts, with a Flesch score of 67 [60; 73]. A small proportion of RIL (13/91; 14%) were illustrated. The RIL were longer (p<0.001), more readable (p<0.001) and more likely to be illustrated (p<0.009) for industrial than for institutional sponsors. Conclusion Researchers should routinely compute the reading ease of study information sheets and make greater efforts to improve the readability of written documents for potential participants. PMID:21494689

  9. Time synchronized video systems

    NASA Technical Reports Server (NTRS)

    Burnett, Ron

    1994-01-01

    The idea of synchronizing multiple video recordings to some type of 'range' time has been tried to varying degrees of success in the past. Combining this requirement with existing time code standards (SMPTE) and the new innovations in desktop multimedia however, have afforded an opportunity to increase the flexibility and usefulness of such efforts without adding costs over the traditional data recording and reduction systems. The concept described can use IRIG, GPS or a battery backed internal clock as the master time source. By converting that time source to Vertical Interval Time Code or Longitudinal Time Code, both in accordance with the SMPTE standards, the user will obtain a tape that contains machine/computer readable time code suitable for use with editing equipment that is available off-the-shelf. Accuracy on playback is then determined by the playback system chosen by the user. Accuracies of +/- 2 frames are common among inexpensive systems and complete frame accuracy is more a matter of the users' budget than the capability of the recording system.

  10. Readability of "Dear Patient" device advisory notification letters created by a device manufacturer.

    PubMed

    Mueller, Luke A; Sharma, Arjun; Ottenberg, Abigale L; Mueller, Paul S

    2013-04-01

    In 2006, the Heart Rhythm Society (HRS) recommended that cardiovascular implantable electronic device (CIED) manufacturers use advisory notification letters to communicate with affected patients. To evaluate the readability of the HRS sample "patient device advisory notification" letter and those created by 1 CIED manufacturer. The HRS sample letter and 25 Boston Scientific Corporation letters dated from 2005 through 2011 were evaluated by using 6 readability tests. Readability (Flesch-Kincaid score) of the HRS sample letter was grade level 12.5, and median readability of the device manufacturer letters was grade level 12.8 (range 10.8-18.9). Similar results were obtained by using other readability scales. No letters had readability scores at the National Work Group on Literacy and Health's recommended reading level-fifth grade; the letters' readability exceeded this recommended level by an average of 7.7 grades (95% confidence interval 6.9-8.5; P<.001). Likewise, no letters had readability scores at the average reading level of US adults-eighth grade; the letters' readability exceeded this level by an average of 4.7 grades (95% confidence interval 3.9-5.5; P< .001). The readability of the HRS sample letter and those created by a CIED manufacturer significantly exceeded the recommended and average US adults' reading skill levels. Such letters are unlikely to be informative to many patients. CIED manufacturers should ensure that advisory letters are comprehensible to most affected patients. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Readability of patient education materials on the American Orthopaedic Society for Sports Medicine website.

    PubMed

    Eltorai, Adam E M; Han, Alex; Truntzer, Jeremy; Daniels, Alan H

    2014-11-01

    The recommended readability of patient education materials by the American Medical Association (AMA) and National Institutes of Health (NIH) should be no greater than a sixth-grade reading level. However, online resources may be too complex for some patients to understand, and poor health literacy predicts inferior health-related quality of life outcomes. This study evaluated whether the American Orthopaedic Society for Sports Medicine (AOSSM) website's patient education materials meet recommended readability guidelines for medical information. We hypothesized that the readability of these online materials would have a Flesch-Kincaid formula grade above the sixth grade. All 65 patient education entries of the AOSSM website were analyzed for grade level readability using the Flesch-Kincaid formula, a widely used and validated tool to evaluate the text reading level. The average (standard deviation) readability of all 65 articles was grade level 10.03 (1.44); 64 articles had a readability score above the sixth-grade level, which is the maximum level recommended by the AMA and NIH. Mean readability of the articles exceeded this level by 4.03 grade levels (95% CI, 3.7-4.4; P < 0.0001). We found post-hoc that only 7 articles had a readability score ≤ an eighth-grade level, the average reading level of US adults. Mean readability of the articles exceeded this level by 2.03 grade levels (95% CI, 1.7-2.4; P < 0.0001). The readability of online AOSSM patient education materials exceeds the readability level recommended by the AMA and NIH, and is above the average reading level of the majority of US adults. This online information may be of limited utility to most patients due to a lack of comprehension. Our study provides a clear example of the need to improve the readability of specific education material in order to maximize the efficacy of multimedia sources.

  12. Is the Readability of Spine-Related Patient Education Material Improving?: An Assessment of Subspecialty Websites.

    PubMed

    Eltorai, Adam E M; Cheatham, Morgan; Naqvi, Syed S; Marthi, Siddharth; Dang, Victor; Palumbo, Mark A; Daniels, Alan H

    2016-06-01

    Analysis of spine-related patient education materials (PEMs) from subspecialty websites. The aim of this study was to assess the readability of spine-related PEMs and compare to readability data from 2008. Many spine patients use the Internet for health information. Several agencies recommend that the readability of online PEMs should be no greater than a sixth-grade reading level, as health literacy predicts health-related quality of life outcomes. This study evaluated whether the North American Spine Society (NASS), American Association of Neurological Surgeons (AANS), and American Academy of Orthopaedic Surgeons (AAOS) online PEMs meet recommended readability guidelines for medical information. All publicly accessible spine-related entries within the patient education section of the NASS, AANS, and AAOS websites were analyzed for grade level readability using the Flesch-Kincaid formula. Readability scores were also compared with a similar 2008 analysis. Comparative statistics were performed. A total of 125 entries from the subspecialty websites were analyzed. The average (SD) readability of the online articles was grade level 10.7 (2.3). Of the articles, 117 (93.6%) had a readability score above the sixth-grade level. The readability of the articles exceeded the maximum recommended level by an average of 4.7 grade levels (95% CI, 4.292-5.103; P < 0.001). Compared with 2008, the three societies published more spine-related patient education articles (61 vs. 125, P = 0.045) and the average readability level improved from 11.5 to 10.7 (P = 0.018). Of three examined societies, only one showed significant improvement over time. Our findings suggest that the spine-related PEMs on the NASS, AAOS, and AANS websites have readability levels that may make comprehension difficult for a substantial portion of the patient population. Although some progress has been made in the readability of PEMs over the past 7 years, additional improvement is necessary. 2.

  13. Neural Networks for Readability Analysis.

    ERIC Educational Resources Information Center

    McEneaney, John E.

    This paper describes and reports on the performance of six related artificial neural networks that have been developed for the purpose of readability analysis. Two networks employ counts of linguistic variables that simulate a traditional regression-based approach to readability. The remaining networks determine readability from "visual…

  14. Quality of Web-based Information for the 10 Most Common Fractures.

    PubMed

    Memon, Muzammil; Ginsberg, Lydia; Simunovic, Nicole; Ristevski, Bill; Bhandari, Mohit; Kleinlugtenbelt, Ydo Vincent

    2016-06-17

    In today's technologically advanced world, 75% of patients have used Google to search for health information. As a result, health care professionals fear that patients may be misinformed. Currently, there is a paucity of data on the quality and readability of Web-based health information on fractures. In this study, we assessed the quality and readability of Web-based health information related to the 10 most common fractures. Using the Google search engine, we assessed websites from the first results page for the 10 most common fractures using lay search terms. Website quality was measured using the DISCERN instrument, which scores websites as very poor (15-22.5), poor (22.5-37.5), fair (37.5-52.5), good (52.5-67.5), or excellent (67.5-75). The presence of Health on the Net code (HONcode) certification was assessed for all websites. Website readability was measured using the Flesch Reading Ease Score (0-100), where 60-69 is ideal for the general public, and the Flesch-Kincaid Grade Level (FKGL; -3.4 to ∞), where the mean FKGL of the US adult population is 8. Overall, website quality was "fair" for all fractures, with a mean (standard deviation) DISCERN score of 50.3 (5.8). The DISCERN score correlated positively with a higher website position on the search results page (r(2)=0.1, P=.002) and with HONcode certification (P=.007). The mean (standard deviation) Flesch Reading Ease Score and FKGL for all fractures were 62.2 (9.1) and 6.7 (1.6), respectively. The quality of Web-based health information on fracture care is fair, and its readability is appropriate for the general public. To obtain higher quality information, patients should select HONcode-certified websites. Furthermore, patients should select websites that are positioned higher on the results page because the Google ranking algorithms appear to rank the websites by quality.

  15. Quality of Web-based Information for the 10 Most Common Fractures

    PubMed Central

    Ginsberg, Lydia; Simunovic, Nicole; Ristevski, Bill; Bhandari, Mohit; Kleinlugtenbelt, Ydo Vincent

    2016-01-01

    Background In today's technologically advanced world, 75% of patients have used Google to search for health information. As a result, health care professionals fear that patients may be misinformed. Currently, there is a paucity of data on the quality and readability of Web-based health information on fractures. Objectives In this study, we assessed the quality and readability of Web-based health information related to the 10 most common fractures. Methods Using the Google search engine, we assessed websites from the first results page for the 10 most common fractures using lay search terms. Website quality was measured using the DISCERN instrument, which scores websites as very poor (15-22.5), poor (22.5-37.5), fair (37.5-52.5), good (52.5-67.5), or excellent (67.5-75). The presence of Health on the Net code (HONcode) certification was assessed for all websites. Website readability was measured using the Flesch Reading Ease Score (0-100), where 60-69 is ideal for the general public, and the Flesch-Kincaid Grade Level (FKGL; −3.4 to ∞), where the mean FKGL of the US adult population is 8. Results Overall, website quality was “fair” for all fractures, with a mean (standard deviation) DISCERN score of 50.3 (5.8). The DISCERN score correlated positively with a higher website position on the search results page (r2=0.1, P=.002) and with HONcode certification (P=.007). The mean (standard deviation) Flesch Reading Ease Score and FKGL for all fractures were 62.2 (9.1) and 6.7 (1.6), respectively. Conclusion The quality of Web-based health information on fracture care is fair, and its readability is appropriate for the general public. To obtain higher quality information, patients should select HONcode-certified websites. Furthermore, patients should select websites that are positioned higher on the results page because the Google ranking algorithms appear to rank the websites by quality. PMID:27317159

  16. Readability assessment of online ophthalmic patient information.

    PubMed

    Edmunds, Matthew R; Barry, Robert J; Denniston, Alastair K

    2013-12-01

    Patients increasingly use the Internet to access information related to their disease, but poor health literacy is known to impact negatively on medical outcomes. Multiple agencies have recommended that patient-oriented literature be written at a fourth- to sixth-grade (9-12 years of age) reading level to assist understanding. The readability of online patient-oriented materials related to ophthalmic diagnoses is not yet known. To assess the readability of online literature specifically for a range of ophthalmic conditions. Body text of the top 10 patient-oriented websites for 16 different ophthalmic diagnoses, covering the full range of ophthalmic subspecialties, was analyzed for readability, source (United Kingdom vs non-United Kingdom, not for profit vs commercial), and appropriateness for sight-impaired readers. Four validated readability formulas were used: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Fog Index (GFOG). Data were compared with the Mann-Whitney test (for 2 groups) and Kruskal-Wallis test (for more than 2 groups) and correlation was assessed by the Spearman r. None of the 160 webpages had readability scores within published guidelines, with 83% assessed as being of "difficult" readability. Not-for-profit webpages were of significantly greater length than commercial webpages (P = .02) and UK-based webpages had slightly superior readability scores compared with those of non-UK webpages (P = .004 to P < .001, depending on the readability formula used). Of all webpages evaluated, only 34% included facility to adjust text size to assist visually impaired readers. To our knowledge, this is the first study to assess readability of patient-focused webpages specifically for a range of ophthalmic diagnoses. In keeping with previous studies in other medical conditions, we determined that readability scores were inferior to those recommended, irrespective of the measure used. Although readability is only one aspect of how well a patient-oriented webpage may be comprehended, we recommend the use of readability scoring when producing such resources in the future. Minimum readability policies and inclusion of facilities within webpages to maximize viewing potential for visually impaired readers are important to ensure that online ophthalmic patient information is accessible to the broadest audience possible.

  17. Variation in the Readability of Items Within Surveys

    PubMed Central

    Calderón, José L.; Morales, Leo S.; Liu, Honghu; Hays, Ron D.

    2006-01-01

    The objective of this study was to estimate the variation in the readability of survey items within 2 widely used health-related quality-of-life surveys: the National Eye Institute Visual Functioning Questionnaire–25 (VFQ-25) and the Short Form Health Survey, version 2 (SF-36v2). Flesch-Kincaid and Flesch Reading Ease formulas were used to estimate readability. Individual survey item scores and descriptive statistics for each survey were calculated. Variation of individual item scores from the mean survey score was graphically depicted for each survey. The mean reading grade level and reading ease estimates for the VFQ-25 and SF-36v2 were 7.8 (fairly easy) and 6.4 (easy), respectively. Both surveys had notable variation in item readability; individual item readability scores ranged from 3.7 to 12.0 (very easy to difficult) for the VFQ-25 and 2.2 to 12.0 (very easy to difficult) for the SF-36v2. Because survey respondents may not comprehend items with readability scores that exceed their reading ability, estimating the readability of each survey item is an important component of evaluating survey readability. Standards for measuring the readability of surveys are needed. PMID:16401705

  18. Quality and readability of English-language internet information for aphasia.

    PubMed

    Azios, Jamie H; Bellon-Harn, Monica; Dockens, Ashley L; Manchaiah, Vinaya

    2017-08-14

    Little is known about the quality and readability of treatment information in specific neurogenic disorders, such as aphasia. The purpose of this study was to assess quality and readability of English-language Internet information available for aphasia treatment. Forty-three aphasia treatment websites were aggregated using five different country-specific search engines. Websites were then analysed using quality and readability assessments. Statistical calculations were employed to examine website ratings, differences between website origin and quality and readability scores, and correlations between readability instruments. Websites exhibited low quality with few websites obtaining Health On the Net (HON) certification or clear, thorough information as measured by the DISCERN. Regardless of website origin, readability scores were also poor. Approximate educational levels required to comprehend information on aphasia treatment websites ranged from 13 to 16 years of education. Significant differences were found between website origin and readability measures with higher levels of education required to understand information on websites of non-profit organisations. Current aphasia treatment websites were found to exhibit low levels of quality and readability, creating potential accessibility problems for people with aphasia and significant others. Websites including treatment information for aphasia must be improved in order to increase greater information accessibility.

  19. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    PubMed

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (p<0.05) between the readability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  20. National Aspects of Creating and Using MARC/RECON Records.

    ERIC Educational Resources Information Center

    Rather, John C., Ed.; Avram, Henriette D., Ed.

    The Retrospective Conversion (RECON) Working Task Force investigated the problems of converting retrospective catalog records to machine readable form. The major conclusions and recommendations of the Task Force cover five areas: the level of machine-readable records, conversion of other machine-readable data bases, a machine-readable National…

  1. Readability Levels of Second Grade Hi-Lo Reading Materials.

    ERIC Educational Resources Information Center

    Hllgendorff, Patricia H.

    The revised Spache Readability Formula and the Fry Readability Formula were applied to 20 selected reading materials designed for adolescents reading at second grade level. Three samples from each text were examined. The results using the Spache formula corresponded to the publisher's stated readability levels, with no significant variability…

  2. Assessing the Readability of Materials for Elementary ESL Pupils.

    ERIC Educational Resources Information Center

    Baldauf, Richard B., Jr.; Propst, Ivan K., Jr.

    This paper assesses the effectiveness of readability indices, standard cloze procedure, and the matching cloze procedure as determinants of the readability of supplementary English materials for elementary ESL students in a Pacific Island context. A review of readability indices and the standard cloze procedure indicated that neither procedure is…

  3. The Readability of Principles of Macroeconomics Textbooks

    ERIC Educational Resources Information Center

    Tinkler, Sarah; Woods, James

    2013-01-01

    The authors evaluated principles of macroeconomics textbooks for readability using Coh-Metrix, a computational linguistics tool. Additionally, they conducted an experiment on Amazon's Mechanical Turk Web site in which participants ranked the readability of text samples. There was a wide range of scores on readability indexes both among…

  4. GenLocDip: A Generalized Program to Calculate and Visualize Local Electric Dipole Moments.

    PubMed

    Groß, Lynn; Herrmann, Carmen

    2016-09-30

    Local dipole moments (i.e., dipole moments of atomic or molecular subsystems) are essential for understanding various phenomena in nanoscience, such as solvent effects on the conductance of single molecules in break junctions or the interaction between the tip and the adsorbate in atomic force microscopy. We introduce GenLocDip, a program for calculating and visualizing local dipole moments of molecular subsystems. GenLocDip currently uses the Atoms-In-Molecules (AIM) partitioning scheme and is interfaced to various AIM programs. This enables postprocessing of a variety of electronic structure output formats including cube and wavefunction files, and, in general, output from any other code capable of writing the electron density on a three-dimensional grid. It uses a modified version of Bader's and Laidig's approach for achieving origin-independence of local dipoles by referring to internal reference points which can (but do not need to be) bond critical points (BCPs). Furthermore, the code allows the export of critical points and local dipole moments into a POVray readable input format. It is particularly designed for fragments of large systems, for which no BCPs have been calculated for computational efficiency reasons, because large interfragment distances prevent their identification, or because a local partitioning scheme different from AIM was used. The program requires only minimal user input and is written in the Fortran90 programming language. To demonstrate the capabilities of the program, examples are given for covalently and non-covalently bound systems, in particular molecular adsorbates. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Emotioncy: A Potential Measure of Readability

    ERIC Educational Resources Information Center

    Pishghadamn, Reza; Abbasnejad, Hannaheh

    2016-01-01

    Given the deficiencies of readability formulae as reliable tools for measuring text readability in educational settings, this study aims to offer a new measure to improve the current methods of testing the readability levels of texts through the incorporation of the newly-developed concept of emotioncy. To this end, a group of 221 students were…

  6. The Readability Graph Validated at Primary Levels.

    ERIC Educational Resources Information Center

    Fry, Edward B.

    The validity of Fry's Readability Graph for determining grade level readability scores was compared with the Spache Formula, the cloze technique, and oral reading in the case of seven primary-level books. Descriptions of these four indicated that to determine grade level, Fry's Readability Graph plots the total number of syllables with the total…

  7. Readability Level of Standardized Test Items and Student Performance: The Forgotten Validity Variable

    ERIC Educational Resources Information Center

    Hewitt, Margaret A.; Homan, Susan P.

    2004-01-01

    Test validity issues considered by test developers and school districts rarely include individual item readability levels. In this study, items from a major standardized test were examined for individual item readability level and item difficulty. The Homan-Hewitt Readability Formula was applied to items across three grade levels. Results of…

  8. The Development and Validation of a Formula for Measuring Single-Sentence Test Item Readability.

    ERIC Educational Resources Information Center

    Homan, Susan; And Others

    1994-01-01

    A study was conducted with 782 elementary school students to determine whether the Homan-Hewitt Readability Formula could identify the readability of a single-sentence test item. Results indicate that a relationship exists between students' reading grade levels and responses to test items written at higher readability levels. (SLD)

  9. The Principles of Readability

    ERIC Educational Resources Information Center

    DuBay, William H.

    2004-01-01

    The principles of readability are in every style manual. Readability formulas are in every writing aid. What is missing is the research and theory on which they stand. This short review of readability research spans 100 years. The first part covers the history of adult literacy studies in the U.S., establishing the stratified nature of the adult…

  10. Readability of online patient education materials from the AAOS web site.

    PubMed

    Sabharwal, Sanjeev; Badarudeen, Sameer; Unes Kunju, Shebna

    2008-05-01

    One of the goals of the American Academy of Orthopaedic Surgeons (AAOS) is to disseminate patient education materials that suit the readability skills of the patient population. According to standard guidelines from healthcare organizations, the readability of patient education materials should be no higher than the sixth-grade level. We hypothesized the readability level of patient education materials available on the AAOS Web site would be higher than the recommended grade level, regardless when the material was available online. Readability scores of all articles from the AAOS Internet-based patient information Web site, "Your Orthopaedic Connection," were determined using the Flesch-Kincaid grade formula. The mean Flesch-Kincaid grade level of the 426 unique articles was 10.43. Only 10 (2%) of the articles had the recommended readability level of sixth grade or lower. The readability of the articles did not change with time. Our findings suggest the majority of the patient education materials available on the AAOS Web site had readability scores that may be too difficult for comprehension by a substantial portion of the patient population.

  11. Readability of Online Patient Education Materials From the AAOS Web Site

    PubMed Central

    Badarudeen, Sameer; Unes Kunju, Shebna

    2008-01-01

    One of the goals of the American Academy of Orthopaedic Surgeons (AAOS) is to disseminate patient education materials that suit the readability skills of the patient population. According to standard guidelines from healthcare organizations, the readability of patient education materials should be no higher than the sixth-grade level. We hypothesized the readability level of patient education materials available on the AAOS Web site would be higher than the recommended grade level, regardless when the material was available online. Readability scores of all articles from the AAOS Internet-based patient information Web site, “Your Orthopaedic Connection,” were determined using the Flesch-Kincaid grade formula. The mean Flesch-Kincaid grade level of the 426 unique articles was 10.43. Only 10 (2%) of the articles had the recommended readability level of sixth grade or lower. The readability of the articles did not change with time. Our findings suggest the majority of the patient education materials available on the AAOS Web site had readability scores that may be too difficult for comprehension by a substantial portion of the patient population. PMID:18324452

  12. Readability Level of Spanish-Language Patient-Reported Outcome Measures in Audiology and Otolaryngology

    PubMed Central

    Coco, Laura; Colina, Sonia; Atcherson, Samuel R.

    2017-01-01

    Purpose The purpose of this study was to examine the readability level of the Spanish versions of several audiology- and otolaryngology-related patient-reported outcome measures (PROMs) and include a readability analysis of 2 translation approaches when available—the published version and a “functionalist” version—using a team-based collaborative approach including community members. Method Readability levels were calculated using the Fry Graph adapted for Spanish, as well as the Fernandez-Huerta and the Spaulding formulae for several commonly used audiology- and otolaryngology-related PROMs. Results Readability calculations agreed with previous studies analyzing audiology-related PROMs in English and demonstrated many Spanish-language PROMs were beyond the 5th grade reading level suggested for health-related materials written for the average population. In addition, the functionalist versions of the PROMs yielded lower grade-level (improved) readability levels than the published versions. Conclusion Our results suggest many of the Spanish-language PROMs evaluated here are beyond the recommended readability levels and may be influenced by the approach to translation. Moreover, improved readability may be possible using a functionalist approach to translation. Future analysis of the suitability of outcome measures and the quality of their translations should move beyond readability and include an evaluation of the individual's comprehension of the written text. PMID:28892821

  13. Clearly written, easily comprehended? The readability of websites providing information on epilepsy.

    PubMed

    Brigo, Francesco; Otte, Willem M; Igwe, Stanley C; Tezzon, Frediano; Nardone, Raffaele

    2015-03-01

    There is a general need for high-quality, easily accessible, and comprehensive health-care information on epilepsy to better inform the general population about this highly stigmatized neurological disorder. The aim of this study was to evaluate the health literacy level of eight popular English-written websites that provide information on epilepsy in quantitative terms of readability. Educational epilepsy material on these websites, including 41 Wikipedia articles, were analyzed for their overall level of readability and the corresponding academic grade level needed to comprehend the published texts on the first reading. The Flesch Reading Ease (FRE) was used to assess ease of comprehension while the Gunning Fog Index, Coleman-Liau Index, Flesch-Kincaid Grade Level, Automated Readability Index, and Simple Measure of Gobbledygook scales estimated the corresponding academic grade level needed for comprehension. The average readability of websites yielded results indicative of a difficult-to-fairly-difficult readability level (FRE results: 44.0±8.2), with text readability corresponding to an 11th academic grade level (11.3±1.9). The average FRE score of the Wikipedia articles was indicative of a difficult readability level (25.6±9.5), with the other readability scales yielding results corresponding to a 14th grade level (14.3±1.7). Popular websites providing information on epilepsy, including Wikipedia, often demonstrate a low level of readability. This can be ameliorated by increasing access to clear and concise online information on epilepsy and health in general. Short "basic" summaries targeted to patients and nonmedical users should be added to articles published in specialist websites and Wikipedia to ease readability. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. [Systematic analysis of the readability of patient information on the websites of clinics for plastic surgery].

    PubMed

    Esfahani, B Janghorban; Faron, A; Roth, K S; Schaller, H-E; Medved, F; Lüers, J-C

    2014-12-01

    The Internet is becoming increasing-ly important as a source of information for patients in medical issues. However, many patients have problems to adequately understand texts, especially with medical content. A basic requirement to understand a written text is the read-ability of a text. The aim of the present study was to examine texts on the websites of German -plastic-surgical hospitals with patient information regarding their readability. In this study, the read-ability of texts of 27 major departments of plastic and Hand surgery in Germany was systematically analysed using 5 recognised readability indices. First, texts were searched based on 20 representative key words and themes. Thereafter, texts were assigned to one of 3 major themes in order to enable statistical analysis. In addition to the 5 readability indices, further objective text parameters were also recorded. Overall, 288 texts were found for analyzation. Most articles were found on the topic of "handsurgery" (n=124), less were found for "facial plastic surgery" (n=80) and "flaps, breast and reconstructive surgery" (n=84). Consistently, all readability indices showed a poor readability for the vast majority of analysed texts with the text appearing readable only for readers with a higher educational level. No significant differences in readability were found between the 3 major themes. Especially in the communication of medical information, it is important to consider the knowledge and education of the addressee. The texts studied consistently showed a readability that is understandable only for academics. Thus, a large part of the intended target group is probably not reached. In order to adequately deliver online information material, a revision of the analysed internet texts appears to be recommendable. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Word add-in for ontology recognition: semantic enrichment of scientific literature.

    PubMed

    Fink, J Lynn; Fernicola, Pablo; Chandran, Rahul; Parastatidis, Savas; Wade, Alex; Naim, Oscar; Quinn, Gregory B; Bourne, Philip E

    2010-02-24

    In the current era of scientific research, efficient communication of information is paramount. As such, the nature of scholarly and scientific communication is changing; cyberinfrastructure is now absolutely necessary and new media are allowing information and knowledge to be more interactive and immediate. One approach to making knowledge more accessible is the addition of machine-readable semantic data to scholarly articles. The Word add-in presented here will assist authors in this effort by automatically recognizing and highlighting words or phrases that are likely information-rich, allowing authors to associate semantic data with those words or phrases, and to embed that data in the document as XML. The add-in and source code are publicly available at http://www.codeplex.com/UCSDBioLit. The Word add-in for ontology term recognition makes it possible for an author to add semantic data to a document as it is being written and it encodes these data using XML tags that are effectively a standard in life sciences literature. Allowing authors to mark-up their own work will help increase the amount and quality of machine-readable literature metadata.

  16. Using Readability Tests to Improve the Accuracy of Evaluation Documents Intended for Low-Literate Participants

    ERIC Educational Resources Information Center

    Kouame, Julien B.

    2010-01-01

    Background: Readability tests are indicators that measure how easy a document can be read and understood. Simple, but very often ignored, readability statistics cannot only provide information about the level of difficulty of the readability of particular documents but also can increase an evaluator's credibility. Purpose: The purpose of this…

  17. 37 CFR 1.825 - Amendments to or replacement of sequence listing and computer readable copy thereof.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of sequence listing and computer readable copy thereof. 1.825 Section 1.825 Patents, Trademarks, and... Amino Acid Sequences § 1.825 Amendments to or replacement of sequence listing and computer readable copy... copy of the computer readable form (§ 1.821(e)) including all previously submitted data with the...

  18. 37 CFR 1.825 - Amendments to or replacement of sequence listing and computer readable copy thereof.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of sequence listing and computer readable copy thereof. 1.825 Section 1.825 Patents, Trademarks, and... Amino Acid Sequences § 1.825 Amendments to or replacement of sequence listing and computer readable copy... copy of the computer readable form (§ 1.821(e)) including all previously submitted data with the...

  19. 37 CFR 1.825 - Amendments to or replacement of sequence listing and computer readable copy thereof.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of sequence listing and computer readable copy thereof. 1.825 Section 1.825 Patents, Trademarks, and... Amino Acid Sequences § 1.825 Amendments to or replacement of sequence listing and computer readable copy... copy of the computer readable form (§ 1.821(e)) including all previously submitted data with the...

  20. A Study of Readability of Texts in Bangla through Machine Learning Approaches

    ERIC Educational Resources Information Center

    Sinha, Manjira; Basu, Anupam

    2016-01-01

    In this work, we have investigated text readability in Bangla language. Text readability is an indicator of the suitability of a given document with respect to a target reader group. Therefore, text readability has huge impact on educational content preparation. The advances in the field of natural language processing have enabled the automatic…

  1. 37 CFR 1.825 - Amendments to or replacement of sequence listing and computer readable copy thereof.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of sequence listing and computer readable copy thereof. 1.825 Section 1.825 Patents, Trademarks, and... Amino Acid Sequences § 1.825 Amendments to or replacement of sequence listing and computer readable copy... copy of the computer readable form (§ 1.821(e)) including all previously submitted data with the...

  2. 37 CFR 1.825 - Amendments to or replacement of sequence listing and computer readable copy thereof.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of sequence listing and computer readable copy thereof. 1.825 Section 1.825 Patents, Trademarks, and... Amino Acid Sequences § 1.825 Amendments to or replacement of sequence listing and computer readable copy... copy of the computer readable form (§ 1.821(e)) including all previously submitted data with the...

  3. Readability analysis of online health information about overactive bladder.

    PubMed

    Koo, Kevin; Shee, Kevin; Yap, Ronald L

    2017-09-01

    Despite the prevalence of overactive bladder (OAB) and the widespread accessibility of patient education information on the Internet, the readability of this information and its potential impact on patient decision-making are not known. This study evaluates the readability of OAB material online in the context of website ownership and the Health on the Net standard for information reliability. Three Internet search platforms were queried daily with OAB-related keywords for 30 days. Readability analysis was performed using the SMOG test, Dale-Chall readability formula, and Fry readability graph. Websites were stratified by ownership type and Health on the Net certification to compare readability metrics. After 270 total searches, 57 websites were analyzed. Mean SMOG reading grade was 10.7 (SD = 1.6) and 10.1 in an adjusted calculation to reduce overestimation from medical jargon. Mean Dale-Chall score was 9.2 (SD = 0.9), or grade 13-15. Mean Fry graph coordinates (177 syllables, 5.9 sentences) corresponded to grade 15. Only seven sites (12%) were predicted to be readable by the average adult with an eighth-grade reading level. Mean reading grades were not significantly different between academic versus commercial sites and Health on the Net-certified versus non-certified sites. A large majority of online information about OAB treatment exceeds the reading ability of most adults. Neither websites sponsored by academic institutions nor those certified by the Health on the Net standard have easier readability. The readability of health information online may be distinct from reliability in the context of urological literacy. © 2017 Wiley Periodicals, Inc.

  4. Universally Designed Text on the Web: Towards Readability Criteria Based on Anti-Patterns.

    PubMed

    Eika, Evelyn

    2016-01-01

    The readability of web texts affects accessibility. The Web Content Accessibility guidelines (WCAG) state that the recommended reading level should match that of someone who has completed basic schooling. However, WCAG does not give advice on what constitutes an appropriate reading level. Web authors need tools to help composing WCAG compliant texts, and specific criteria are needed. Classic readability metrics are generally based on lengths of words and sentences and have been criticized for being over-simplistic. Automatic measures and classifications of texts' reading levels employing more advanced constructs remain an unresolved problem. If such measures were feasible, what should these be? This work examines three language constructs not captured by current readability indices but believed to significantly affect actual readability, namely, relative clauses, garden path sentences, and left-branching structures. The goal is to see whether quantifications of these stylistic features reflect readability and how they correspond to common readability measures. Manual assessments of a set of authentic web texts for such uses were conducted. The results reveal that texts related to narratives such as children's stories, which are given the highest readability value, do not contain these constructs. The structures in question occur more frequently in expository texts that aim at educating or disseminating information such as strategy and journal articles. The results suggest that language anti-patterns hold potential for establishing a set of deeper readability criteria.

  5. Adding Concrete Syntax to a Prolog-Based Program Synthesis System

    NASA Technical Reports Server (NTRS)

    Fischer, Bernd; Visser, Eelco

    2003-01-01

    Program generation and transformation systems manipulate large, pa- rameterized object language fragments. Support for user-definable concrete syntax makes this easier but is typically restricted to certain object and meta languages. We show how Prolog can be retrofitted with concrete syntax and describe how a seamless interaction of concrete syntax fragments with an existing legacy meta-programming system based on abstract syntax is achieved. We apply the approach to gradually migrate the schemas of the AUTOBAYES program synthesis system to concrete syntax. Fit experiences show that this can result in a considerable reduction of the code size and an improved readability of the code. In particular, abstracting out fresh-variable generation and second-order term construction allows the formulation of larger continuous fragments and improves the locality in the schemas.

  6. Readability Levels of First and Second Grade Basal Texts.

    ERIC Educational Resources Information Center

    Langan, Yvette

    The Fry Readability Formula was used to determine the readability levels of 12 first and second grade basal texts. These texts were part of the Ginn 360, Ginn 720, and Macmillan Series "r" basal reader series. The results showed that 4 of the 12 books tested did not correspond closely to the publisher's readability levels. The Ginn 720 text for…

  7. How readable are Australian paediatric oral health education materials?

    PubMed

    Arora, Amit; Lam, Andy S F; Karami, Zahra; Do, Loc Giang; Harris, Mark Fort

    2014-09-02

    The objective of this study was to analyse the readability of paediatric oral health education leaflets available in Australia. Forty paediatric oral health education materials were analysed for general readability according to the following parameters: Thoroughness; Textual framework; Terminology; and Readability (Flesch-Kincaid grade level (FKGL), Gunning Fog index (Fog) and Simplified Measure of Gobbledygook (SMOG)). Leaflets produced by the industry were among the hardest to read with an average readability at the 8th grade (8.4 ± 0.1). The readability of leaflets produced by the commercial sector was at the 7th grade (7.1 ± 1.7) and the government at the 6th grade (6.3 ± 1.9). The FKGL consistently yielded readabilities 2 grades below the Fog and SMOG indexes. In the content analyses, 14 essential paediatric oral health topics were noted and Early Childhood Caries (ECC) was identified as the most commonly used jargon term. Paediatric oral health education materials are readily available, yet their quality and readability vary widely and may be difficult to read for disadvantaged populations in Australia. A redesign of these leaflets while taking literacy into consideration is suggested.

  8. Status of BOUT fluid turbulence code: improvements and verification

    NASA Astrophysics Data System (ADS)

    Umansky, M. V.; Lodestro, L. L.; Xu, X. Q.

    2006-10-01

    BOUT is an electromagnetic fluid turbulence code for tokamak edge plasma [1]. BOUT performs time integration of reduced Braginskii plasma fluid equations, using spatial discretization in realistic geometry and employing a standard ODE integration package PVODE. BOUT has been applied to several tokamak experiments and in some cases calculated spectra of turbulent fluctuations compared favorably to experimental data. On the other hand, the desire to understand better the code results and to gain more confidence in it motivated investing effort in rigorous verification of BOUT. Parallel to the testing the code underwent substantial modification, mainly to improve its readability and tractability of physical terms, with some algorithmic improvements as well. In the verification process, a series of linear and nonlinear test problems was applied to BOUT, targeting different subgroups of physical terms. The tests include reproducing basic electrostatic and electromagnetic plasma modes in simplified geometry, axisymmetric benchmarks against the 2D edge code UEDGE in real divertor geometry, and neutral fluid benchmarks against the hydrodynamic code LCPFCT. After completion of the testing, the new version of the code is being applied to actual tokamak edge turbulence problems, and the results will be presented. [1] X. Q. Xu et al., Contr. Plas. Phys., 36,158 (1998). *Work performed for USDOE by Univ. Calif. LLNL under contract W-7405-ENG-48.

  9. A systematic review of readability and comprehension instruments used for print and web-based cancer information.

    PubMed

    Friedman, Daniela B; Hoffman-Goetz, Laurie

    2006-06-01

    Adequate functional literacy skills positively influence individuals' ability to take control of their health. Print and Web-based cancer information is often written at difficult reading levels. This systematic review evaluates readability instruments (FRE, F-K, Fog, SMOG, Fry) used to assess print and Web-based cancer information and word recognition and comprehension tests (Cloze, REALM, TOFHLA, WRAT) that measure people's health literacy. Articles on readability and comprehension instruments explicitly used for cancer information were assembled by searching MEDLINE and Psyc INFO from 1993 to 2003. In all, 23 studies were included; 16 on readability, 6 on comprehension, and 1 on readability and comprehension. Of the readability investigations, 14 focused on print materials, and 2 assessed Internet information. Comprehension and word recognition measures were not applied to Web-based information. None of the formulas were designed to determine the effects of visuals or design factors that could influence readability and comprehension of cancer education information.

  10. A language comparison for scientific computing on MIMD architectures

    NASA Technical Reports Server (NTRS)

    Jones, Mark T.; Patrick, Merrell L.; Voigt, Robert G.

    1989-01-01

    Choleski's method for solving banded symmetric, positive definite systems is implemented on a multiprocessor computer using three FORTRAN based parallel programming languages, the Force, PISCES and Concurrent FORTRAN. The capabilities of the language for expressing parallelism and their user friendliness are discussed, including readability of the code, debugging assistance offered, and expressiveness of the languages. The performance of the different implementations is compared. It is argued that PISCES, using the Force for medium-grained parallelism, is the appropriate choice for programming Choleski's method on the multiprocessor computer, Flex/32.

  11. QuantumOptics.jl: A Julia framework for simulating open quantum systems

    NASA Astrophysics Data System (ADS)

    Krämer, Sebastian; Plankensteiner, David; Ostermann, Laurin; Ritsch, Helmut

    2018-06-01

    We present an open source computational framework geared towards the efficient numerical investigation of open quantum systems written in the Julia programming language. Built exclusively in Julia and based on standard quantum optics notation, the toolbox offers speed comparable to low-level statically typed languages, without compromising on the accessibility and code readability found in dynamic languages. After introducing the framework, we highlight its features and showcase implementations of generic quantum models. Finally, we compare its usability and performance to two well-established and widely used numerical quantum libraries.

  12. X-Ray Diffraction Contrast Tomography in micro-CT Lab Source Systems

    DTIC Science & Technology

    2014-05-16

    microstrucutre as determined from DCT. (e) Surface mesh representing the fracture surface, colour coded with respect to its crystallographic orientation. Grain...sake of readability, we refrain from delving too deep into the mathematics of the projection models. Instead, we refer to Appendix A where more in...S−D 2 ). From the definition of the dot product, we learn that cos θ = B ·G ‖B‖‖G‖ = B ·G f . 1.9 Given sin2 θ + cos2 θ = 1, sin θ can be also

  13. Readability of online patient education materials on adult reconstruction Web sites.

    PubMed

    Polishchuk, Daniil L; Hashem, Jenifer; Sabharwal, Sanjeev

    2012-05-01

    Recommended readability of patient education materials is sixth-grade level or lower. Readability of 212 patient education materials pertaining to adult reconstruction topics available from the American Academy of Orthopaedic Surgeons, American Association of Hip and Knee Surgeons, and 3 other specialty and private practitioner Web sites was assessed using the Flesch-Kincaid grade formula. The mean Flesch-Kincaid score was 11.1 (range, 3-26.5). Only 5 (2%) articles had a readability level of sixth grade or lower. Readability of most of the articles for patient education on adult reconstruction Web sites evaluated may be too advanced for a substantial portion of patients. Further studies are needed to assess the optimal readability level of health information on the Internet. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. The Readability Levels of the 1981 Scott, Foresman and Co. Basal Texts and Their Comparison with the 1978 Edition.

    ERIC Educational Resources Information Center

    Ackerman, Bonnie

    Fry's Readability Graph was used to determine the readability levels of the 1981 Scott, Foresman and Co. basal textbook series for grades one through six. The readability levels were then compared to those established for the 1978 edition. In the 1981 edition, all stories were handscored. Poems, skill lessons, and plays were not examined in order…

  15. Improving the readability of online foot and ankle patient education materials.

    PubMed

    Sheppard, Evan D; Hyde, Zane; Florence, Mason N; McGwin, Gerald; Kirchner, John S; Ponce, Brent A

    2014-12-01

    Previous studies have shown the need for improving the readability of many patient education materials to increase patient comprehension. This study's purpose was to determine the readability of foot and ankle patient education materials and to determine the extent readability can be improved. We hypothesized that the reading levels would be above the recommended guidelines and that decreasing the sentence length would also decrease the reading level of these patient educational materials. Patient education materials from online public sources were collected. The readability of these articles was assessed by a readability software program. The detailed instructions provided by the National Institutes of Health (NIH) were then used as a guideline for performing edits to help improve the readability of selected articles. The most quantitative guideline, lowering all sentences to less than 15 words, was chosen to show the effect of following the NIH recommendations. The reading levels of the sampled articles were above the sixth to seventh grade recommendations of the NIH. The MedlinePlus website, which is a part of the NIH website, had the lowest reading level (8.1). The articles edited had an average reduction of 1.41 grade levels, with the lowest reduction in the Medline articles of 0.65. Providing detailed instructions to the authors writing these patient education articles and implementing editing techniques based on previous recommendations could lead to an improvement in the readability of patient education materials. This study provides authors of patient education materials with simple editing techniques that will allow for the improvement in the readability of online patient educational materials. The improvement in readability will provide patients with more comprehendible education materials that can strengthen patient awareness of medical problems and treatments. © The Author(s) 2014.

  16. Readability of Online Patient Educational Resources Found on NCI-Designated Cancer Center Web Sites.

    PubMed

    Rosenberg, Stephen A; Francis, David; Hullett, Craig R; Morris, Zachary S; Fisher, Michael M; Brower, Jeffrey V; Bradley, Kristin A; Anderson, Bethany M; Bassetti, Michael F; Kimple, Randall J

    2016-06-01

    The NIH and Department of Health & Human Services recommend online patient information (OPI) be written at a sixth grade level. We used a panel of readability analyses to assess OPI from NCI-Designated Cancer Center (NCIDCC) Web sites. Cancer.gov was used to identify 68 NCIDCC Web sites from which we collected both general OPI and OPI specific to breast, prostate, lung, and colon cancers. This text was analyzed by 10 commonly used readability tests: the New Dale-Chall Readability Formula, Flesch Reading Ease scale, Flesch-Kinaid Grade Level, FORCAST scale, Fry Readability Graph, Simple Measure of Gobbledygook test, Gunning Frequency of Gobbledygook index, New Fog Count, Raygor Readability Estimate Graph, and Coleman-Liau Index. We tested the hypothesis that the readability of NCIDCC OPI was written at the sixth grade level. Secondary analyses were performed to compare readability of OPI between comprehensive and noncomprehensive centers, by region, and to OPI produced by the American Cancer Society (ACS). A mean of 30,507 words from 40 comprehensive and 18 noncomprehensive NCIDCCs was analyzed (7 nonclinical and 3 without appropriate OPI were excluded). Using a composite grade level score, the mean readability score of 12.46 (ie, college level: 95% CI, 12.13-12.79) was significantly greater than the target grade level of 6 (middle-school: P<.001). No difference between comprehensive and noncomprehensive centers was identified. Regional differences were identified in 4 of the 10 readability metrics (P<.05). ACS OPI provides easier language, at the seventh to ninth grade level, across all tests (P<.01). OPI from NCIDCC Web sites is more complex than recommended for the average patient. Copyright © 2016 by the National Comprehensive Cancer Network.

  17. [Readability of surgical informed consent in Spain].

    PubMed

    San Norberto, Enrique María; Gómez-Alonso, Daniel; Trigueros, José M; Quiroga, Jorge; Gualis, Javier; Vaquero, Carlos

    2014-03-01

    To assess the readability of informed consent documents (IC) of the different national surgical societies. During January 2012 we collected 504 IC protocols of different specialties. To calculate readability parameters the following criteria were assessed: number of words, syllables and phrases, syllables/word and word/phrase averages, Word correlation index, Flesch-Szigriszt index, Huerta Fernández index, Inflesz scale degree and the Gunning-Fog index. The mean Flesch-Szigriszt index was 50.65 ± 6,72, so readability is considered normal. There are significant differences between specialties such as Urology (43.00 ± 4.17) and Angiology and Vascular Surgery (63.00 ± 3.26, P<.001). No IC would be appropriate for adult readability according to the Fernández-Huerta index (total mean 55.77 ± 6.57); the IC of Angiology and Vascular Surgery were the closest ones (67.85 ± 3.20). Considering the Inflesz scale degree (total mean of 2.84 ± 3,23), IC can be described as «somewhat difficult». There are significant differences between the IC of Angiology and Vascular Surgery (3.23 ± 0.47) that could be qualified as normal, or Cardiovascular Surgery (2.79 ± 0.43) as «nearly normal readability»; and others such as Urology (1, 70 ± 0.46, P<.001) and Thoracic Surgery (1.90 ± 0.30, P<.001), with a readability between «very» and «somewhat» difficult. The Gunning-Fog indexes are far from the readability for a general audience (total mean of 26.29 ± 10,89). IC developed by scientific societies of different surgical specialties do not have an adequate readability for patients. We recommend the use of readability indexes during the writing of these consent forms. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  18. PlasmaPy: initial development of a Python package for plasma physics

    NASA Astrophysics Data System (ADS)

    Murphy, Nicholas; Leonard, Andrew J.; Stańczak, Dominik; Haggerty, Colby C.; Parashar, Tulasi N.; Huang, Yu-Min; PlasmaPy Community

    2017-10-01

    We report on initial development of PlasmaPy: an open source community-driven Python package for plasma physics. PlasmaPy seeks to provide core functionality that is needed for the formation of a fully open source Python ecosystem for plasma physics. PlasmaPy prioritizes code readability, consistency, and maintainability while using best practices for scientific computing such as version control, continuous integration testing, embedding documentation in code, and code review. We discuss our current and planned capabilities, including features presently under development. The development roadmap includes features such as fluid and particle simulation capabilities, a Grad-Shafranov solver, a dispersion relation solver, atomic data retrieval methods, and tools to analyze simulations and experiments. We describe several ways to contribute to PlasmaPy. PlasmaPy has a code of conduct and is being developed under a BSD license, with a version 0.1 release planned for 2018. The success of PlasmaPy depends on active community involvement, so anyone interested in contributing to this project should contact the authors. This work was partially supported by the U.S. Department of Energy.

  19. ALPS - A LINEAR PROGRAM SOLVER

    NASA Technical Reports Server (NTRS)

    Viterna, L. A.

    1994-01-01

    Linear programming is a widely-used engineering and management tool. Scheduling, resource allocation, and production planning are all well-known applications of linear programs (LP's). Most LP's are too large to be solved by hand, so over the decades many computer codes for solving LP's have been developed. ALPS, A Linear Program Solver, is a full-featured LP analysis program. ALPS can solve plain linear programs as well as more complicated mixed integer and pure integer programs. ALPS also contains an efficient solution technique for pure binary (0-1 integer) programs. One of the many weaknesses of LP solvers is the lack of interaction with the user. ALPS is a menu-driven program with no special commands or keywords to learn. In addition, ALPS contains a full-screen editor to enter and maintain the LP formulation. These formulations can be written to and read from plain ASCII files for portability. For those less experienced in LP formulation, ALPS contains a problem "parser" which checks the formulation for errors. ALPS creates fully formatted, readable reports that can be sent to a printer or output file. ALPS is written entirely in IBM's APL2/PC product, Version 1.01. The APL2 workspace containing all the ALPS code can be run on any APL2/PC system (AT or 386). On a 32-bit system, this configuration can take advantage of all extended memory. The user can also examine and modify the ALPS code. The APL2 workspace has also been "packed" to be run on any DOS system (without APL2) as a stand-alone "EXE" file, but has limited memory capacity on a 640K system. A numeric coprocessor (80X87) is optional but recommended. The standard distribution medium for ALPS is a 5.25 inch 360K MS-DOS format diskette. IBM, IBM PC and IBM APL2 are registered trademarks of International Business Machines Corporation. MS-DOS is a registered trademark of Microsoft Corporation.

  20. Reply to "Further issues in determining the readability of self-report items: comment on McHugh and Behar (2009)".

    PubMed

    McHugh, R Kathryn; Behar, Evelyn

    2012-12-01

    In his commentary on our previously published article "Readability of Self-Report Measures of Depression and Anxiety," J. Schinka (2012) argued for the importance of considering readability of patient materials and highlighted limitations of existing methodologies for this assessment. Schinka's commentary articulately described the weaknesses of readability assessment and emphasized the importance of the development of improved strategies for assessing readability to maximize the validity of self-report measures in applied settings. In our reply, we support and extend Schinka's argument, highlighting the importance of consideration of the range of factors (e.g., use of reverse-scored items) that may increase respondent difficulty with comprehension. Consideration of the readability of self-report symptom measures is critical to the validity of these measures in both clinical practice and research settings.

  1. Readability of Invasive Procedure Consent Forms.

    PubMed

    Eltorai, Adam E M; Naqvi, Syed S; Ghanian, Soha; Eberson, Craig P; Weiss, Arnold-Peter C; Born, Christopher T; Daniels, Alan H

    2015-12-01

    Informed consent is a pillar of ethical medicine which requires patients to fully comprehend relevant issues including the risks, benefits, and alternatives of an intervention. Given the average reading skill of US adults is at the 8th grade level, the American Medical Association (AMA) and the National Institutes of Health (NIH) recommend patient information materials should not exceed a 6th grade reading level. We hypothesized that text provided in invasive procedure consent forms would exceed recommended readability guidelines for medical information. To test this hypothesis, we gathered procedure consent forms from all surgical inpatient hospitals in the state of Rhode Island. For each consent form, readability analysis was measured with the following measures: Flesch Reading Ease Formula, Flesch-Kincaid Grade Level, Fog Scale, SMOG Index, Coleman-Liau Index, Automated Readability Index, and Linsear Write Formula. These readability scores were used to calculate a composite Text Readability Consensus Grade Level. Invasive procedure consent forms were found to be written at an average of 15th grade level (i.e., third year of college), which is significantly higher than the average US adult reading level of 8th grade (p < 0.0001) and the AMA/NIH recommended readability guidelines for patient materials of 6th grade (p < 0.0001). Invasive procedure consent forms have readability levels which makes comprehension difficult or impossible for many patients. Efforts to improve the readability of procedural consent forms should improve patient understanding regarding their healthcare decisions. © 2015 Wiley Periodicals, Inc.

  2. Readability of Invasive Procedure Consent Forms

    PubMed Central

    Eltorai, Adam E. M.; Naqvi, Syed S.; Ghanian, Soha; Eberson, Craig P.; Weiss, Arnold‐Peter C.; Born, Christopher T.

    2015-01-01

    Abstract Background Informed consent is a pillar of ethical medicine which requires patients to fully comprehend relevant issues including the risks, benefits, and alternatives of an intervention. Given the average reading skill of US adults is at the 8th grade level, the American Medical Association (AMA) and the National Institutes of Health (NIH) recommend patient information materials should not exceed a 6th grade reading level. We hypothesized that text provided in invasive procedure consent forms would exceed recommended readability guidelines for medical information. Materials and methods To test this hypothesis, we gathered procedure consent forms from all surgical inpatient hospitals in the state of Rhode Island. For each consent form, readability analysis was measured with the following measures: Flesch Reading Ease Formula, Flesch–Kincaid Grade Level, Fog Scale, SMOG Index, Coleman–Liau Index, Automated Readability Index, and Linsear Write Formula. These readability scores were used to calculate a composite Text Readability Consensus Grade Level. Results Invasive procedure consent forms were found to be written at an average of 15th grade level (i.e., third year of college), which is significantly higher than the average US adult reading level of 8th grade (p < 0.0001) and the AMA/NIH recommended readability guidelines for patient materials of 6th grade (p < 0.0001). Conclusion Invasive procedure consent forms have readability levels which makes comprehension difficult or impossible for many patients. Efforts to improve the readability of procedural consent forms should improve patient understanding regarding their healthcare decisions. PMID:26678039

  3. Readability and Understandability of Online Vocal Cord Paralysis Materials.

    PubMed

    Balakrishnan, Vini; Chandy, Zachariah; Hseih, Amy; Bui, Thanh-Lan; Verma, Sunil P

    2016-03-01

    Patients use several online resources to learn about vocal cord paralysis (VCP). The objective of this study was to assess the readability and understandability of online VCP patient education materials (PEMs), with readability assessments and the Patient Education Materials Evaluation Tool (PEMAT), respectively. The relationship between readability and understandability was then analyzed. Descriptive and correlational design. Online PEMs were identified by performing a Google search with the term "vocal cord paralysis." After scientific webpages, news articles, and information for medical professionals were excluded, 29 articles from the first 50 search results were considered. Readability analysis was performed with 6 formulas. Four individuals with different educational backgrounds conducted understandability analysis with the PEMAT. Fleiss's Kappa interrater reliability analysis determined consistency among raters. Correlation between readability and understandability was determined with Pearson's correlation test. The reading level of the reviewed articles ranged from grades 9 to 17. Understandability ranged from 29% to 82%. Correlation analysis demonstrated a strong negative correlation between materials' readability and understandability (r = -0.462, P < .05). Online PEMs pertaining to VCP are written above the recommended reading levels. Overall, materials written at lower grade levels are more understandable. However, articles of identical grade levels had varying levels of understandability. The PEMAT may provide a more critical evaluation of the quality of a PEM when compared with readability formulas. Both readability and understandability should be used to evaluate PEMs. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  4. Assessment of Readability and Learning of Easy-to-Read Educational Health Materials Designed and Written with the Help of Citizens by Means of Two Non-Alternative Methods

    ERIC Educational Resources Information Center

    Daghio, M. Monica; Fattori, Giuseppe; Ciardullo, Anna V.

    2006-01-01

    Objectives: We compared two non-alternative methods to assess the readability and learning of easy-to-read educational health materials co-written by physicians, educators and citizens. Methods: Data from seven easy-to-read materials were analyzed. Readability formulae, and ad hoc data on readability and learning were also computed. Results: The…

  5. Readability Assessment of Online Patient Education Material on Congestive Heart Failure.

    PubMed

    Kher, Akhil; Johnson, Sandra; Griffith, Robert

    2017-01-01

    Online health information is being used more ubiquitously by the general population. However, this information typically favors only a small percentage of readers, which can result in suboptimal medical outcomes for patients. The readability of online patient education materials regarding the topic of congestive heart failure was assessed through six readability assessment tools. The search phrase "congestive heart failure" was employed into the search engine Google. Out of the first 100 websites, only 70 were included attending to compliance with selection and exclusion criteria. These were then assessed through six readability assessment tools. Only 5 out of 70 websites were within the limits of the recommended sixth-grade readability level. The mean readability scores were as follows: the Flesch-Kincaid Grade Level (9.79), Gunning-Fog Score (11.95), Coleman-Liau Index (15.17), Simple Measure of Gobbledygook (SMOG) index (11.39), and the Flesch Reading Ease (48.87). Most of the analyzed websites were found to be above the sixth-grade readability level recommendations. Efforts need to be made to better tailor online patient education materials to the general population.

  6. Laser direct marking applied to rasterizing miniature Data Matrix Code on aluminum alloy

    NASA Astrophysics Data System (ADS)

    Li, Xia-Shuang; He, Wei-Ping; Lei, Lei; Wang, Jian; Guo, Gai-Fang; Zhang, Teng-Yun; Yue, Ting

    2016-03-01

    Precise miniaturization of 2D Data Matrix (DM) Codes on Aluminum alloy formed by raster mode laser direct part marking is demonstrated. The characteristic edge over-burn effects, which render vector mode laser direct part marking inadequate for producing precise and readable miniature codes, are minimized with raster mode laser marking. To obtain the control mechanism for the contrast and print growth of miniature DM code by raster laser marking process, the temperature field model of long pulse laser interaction with material is established. From the experimental results, laser average power and Q frequency have an important effect on the contrast and print growth of miniature DM code, and the threshold of laser average power and Q frequency for an identifiable miniature DM code are respectively 3.6 W and 110 kHz, which matches the model well within normal operating conditions. In addition, the empirical model of correlation occurring between laser marking parameters and module size is also obtained, and the optimal processing parameter values for an identifiable miniature DM code of different but certain data size are given. It is also found that an increase of the repeat scanning number effectively improves the surface finish of bore, the appearance consistency of modules, which has benefit to reading. The reading quality of miniature DM code is greatly improved using ultrasonic cleaning in water by avoiding the interference of color speckles surrounding modules.

  7. Assessing the Accuracy and Readability of Online Health Information for Patients With Pancreatic Cancer.

    PubMed

    Storino, Alessandra; Castillo-Angeles, Manuel; Watkins, Ammara A; Vargas, Christina; Mancias, Joseph D; Bullock, Andrea; Demirjian, Aram; Moser, A James; Kent, Tara S

    2016-09-01

    The degree to which patients are empowered by written educational materials depends on the text's readability level and the accuracy of the information provided. The association of a website's affiliation or focus on treatment modality with its readability and accuracy has yet to be thoroughly elucidated. To compare the readability and accuracy of patient-oriented online resources for pancreatic cancer by treatment modality and website affiliation. An online search of 50 websites discussing 5 pancreatic cancer treatment modalities (alternative therapy, chemotherapy, clinical trials, radiation therapy, and surgery) was conducted. The website's affiliation was identified. Readability was measured by 9 standardized tests, and accuracy was assessed by an expert panel. Nine standardized tests were used to compute the median readability level of each website. The median readability scores were compared among treatment modality and affiliation categories. Accuracy was determined by an expert panel consisting of 2 medical specialists and 2 surgical specialists. The 4 raters independently evaluated all websites belonging to the 5 treatment modalities (a score of 1 indicates that <25% of the information is accurate, a score of 2 indicates that 26%-50% of the information is accurate, a score of 3 indicates that 51%-75% of the information is accurate, a score of 4 indicates that 76%-99% of the information is accurate, and a score of 5 indicates that 100% of the information is accurate). The 50 evaluated websites differed in readability and accuracy based on the focus of the treatment modality and the website's affiliation. Websites discussing surgery (with a median readability level of 13.7 and an interquartile range [IQR] of 11.9-15.6) were easier to read than those discussing radiotherapy (median readability level, 15.2 [IQR, 13.0-17.0]) (P = .003) and clinical trials (median readability level, 15.2 [IQR, 12.8-17.0]) (P = .002). Websites of nonprofit organizations (median readability level, 12.9 [IQR, 11.2-15.0]) were easier to read than media (median readability level, 16.0 [IQR, 13.4-17.0]) (P < .001) and academic (median readability level, 14.8 [IQR, 12.9-17.0]) (P < .001) websites. Privately owned websites (median readability level, 14.0 [IQR, 12.1-16.1]) were easier to read than media websites (P = .001). Among treatment modalities, alternative therapy websites exhibited the lowest accuracy scores (median accuracy score, 2 [IQR, 1-4]) (P < .001). Nonprofit (median accuracy score, 4 [IQR, 4-5]), government (median accuracy score, 5 [IQR, 4-5]), and academic (median accuracy score, 4 [IQR, 3.5-5]) websites were more accurate than privately owned (median accuracy score, 3.5 [IQR, 1.5-4]) and media (median accuracy score, 4 [IQR, 2-4]) websites (P < .004). Websites with higher accuracy were more difficult to read than websites with lower accuracy. Online information on pancreatic cancer overestimates the reading ability of the overall population and lacks accurate information about alternative therapy. In the absence of quality control on the Internet, physicians should provide guidance to patients in the selection of online resources with readable and accurate information.

  8. Readability Analysis of the Package Leaflets for Biological Medicines Available on the Internet Between 2007 and 2013: An Analytical Longitudinal Study

    PubMed Central

    2016-01-01

    Background The package leaflet included in the packaging of all medicinal products plays an important role in the transmission of medicine-related information to patients. Therefore, in 2009, the European Commission published readability guidelines to try to ensure that the information contained in the package leaflet is understood by patients. Objective The main objective of this study was to calculate and compare the readability levels and length (number of words) of the package leaflets for biological medicines in 2007, 2010, and 2013. Methods The sample of this study included 36 biological medicine package leaflets that were downloaded from the European Medicines Agency website in three different years: 2007, 2010, and 2013. The readability of the selected package leaflets was obtained using the following readability formulas: SMOG grade, Flesch-Kincaid grade level, and Szigriszt’s perspicuity index. The length (number of words) of the package leaflets was also measured. Afterwards, the relationship between these quantitative variables (three readability indexes and length) and categorical (or qualitative) variables were analyzed. The categorical variables were the year when the package leaflet was downloaded, the package leaflet section, type of medicine, year of authorization of biological medicine, and marketing authorization holder. Results The readability values of all the package leaflets exceeded the sixth-grade reading level, which is the recommended value for health-related written materials. No statistically significant differences were found between the three years of study in the readability indexes, although differences were observed in the case of the length (P=.002), which increased over the study period. When the relationship between readability indexes and length and the other variables was analyzed, statistically significant differences were found between package leaflet sections (P<.001) and between the groups of medicine only with regard to the length over the three studied years (P=.002 in 2007, P=.007 in 2010, P=.009 in 2013). Linear correlation was observed between the readability indexes (SMOG grade and Flesch-Kincaid grade level: r2=.92; SMOG grade and Szigriszt’s perspicuity index: r2=.81; Flesch-Kincaid grade level and Szigriszt’s perspicuity index: r2=.95), but not between the readability indexes and the length (length and SMOG grade: r2=.05; length and Flesch-Kincaid grade level: r2=.03; length and Szigriszt’s perspicuity index: r2=.02). Conclusions There was no improvement in the readability of the package leaflets studied between 2007 and 2013 despite the European Commission’s 2009 guideline on the readability of package leaflets. The results obtained from the different readability formulas coincided from a qualitative point of view. Efforts to improve the readability of package leaflets for biological medicines are required to promote the understandability and accessibility of this online health information by patients and thereby contribute to the appropriate use of medicines and medicine safety. PMID:27226241

  9. Readability Analysis of the Package Leaflets for Biological Medicines Available on the Internet Between 2007 and 2013: An Analytical Longitudinal Study.

    PubMed

    Piñero-López, María Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2016-05-25

    The package leaflet included in the packaging of all medicinal products plays an important role in the transmission of medicine-related information to patients. Therefore, in 2009, the European Commission published readability guidelines to try to ensure that the information contained in the package leaflet is understood by patients. The main objective of this study was to calculate and compare the readability levels and length (number of words) of the package leaflets for biological medicines in 2007, 2010, and 2013. The sample of this study included 36 biological medicine package leaflets that were downloaded from the European Medicines Agency website in three different years: 2007, 2010, and 2013. The readability of the selected package leaflets was obtained using the following readability formulas: SMOG grade, Flesch-Kincaid grade level, and Szigriszt's perspicuity index. The length (number of words) of the package leaflets was also measured. Afterwards, the relationship between these quantitative variables (three readability indexes and length) and categorical (or qualitative) variables were analyzed. The categorical variables were the year when the package leaflet was downloaded, the package leaflet section, type of medicine, year of authorization of biological medicine, and marketing authorization holder. The readability values of all the package leaflets exceeded the sixth-grade reading level, which is the recommended value for health-related written materials. No statistically significant differences were found between the three years of study in the readability indexes, although differences were observed in the case of the length (P=.002), which increased over the study period. When the relationship between readability indexes and length and the other variables was analyzed, statistically significant differences were found between package leaflet sections (P<.001) and between the groups of medicine only with regard to the length over the three studied years (P=.002 in 2007, P=.007 in 2010, P=.009 in 2013). Linear correlation was observed between the readability indexes (SMOG grade and Flesch-Kincaid grade level: r(2)=.92; SMOG grade and Szigriszt's perspicuity index: r(2)=.81; Flesch-Kincaid grade level and Szigriszt's perspicuity index: r(2)=.95), but not between the readability indexes and the length (length and SMOG grade: r(2)=.05; length and Flesch-Kincaid grade level: r(2)=.03; length and Szigriszt's perspicuity index: r(2)=.02). There was no improvement in the readability of the package leaflets studied between 2007 and 2013 despite the European Commission's 2009 guideline on the readability of package leaflets. The results obtained from the different readability formulas coincided from a qualitative point of view. Efforts to improve the readability of package leaflets for biological medicines are required to promote the understandability and accessibility of this online health information by patients and thereby contribute to the appropriate use of medicines and medicine safety.

  10. A Comparison of the Readability of Selected Instructions, Publications and Forms Commonly Used by Adults and the Minimum Literacy Level as Defined by the United States Office of Education.

    ERIC Educational Resources Information Center

    Beris, Carole

    The Fry Readability Graph was used to assess the approximate readability level of each of 23 selected instructions, publications, and forms commonly used by adults in order to compare their readability levels with the minimum literacy level as defined by the United States Office of Education (approximately the eighth grade level). The results…

  11. How Readable Is BPH Treatment Information on the Internet? Assessing Barriers to Literacy in Prostate Health

    PubMed Central

    Koo, Kevin; Yap, Ronald L.

    2016-01-01

    Information about benign prostatic hyperplasia (BPH) has become increasingly accessible on the Internet. Though the ability to find such material is encouraging, its readability and impact on informing patient decision making are not known. To evaluate the readability of Internet-based information about BPH in the context of website ownership and Health on the Net certification, three search engines were queried daily for 1 month with BPH-related keywords. Website ownership data and Health on the Net certification status were verified. Three readability analyses were performed: SMOG test, Dale–Chall readability formula, and Fry readability graph. An adjusted SMOG calculation was performed to reduce overestimation from medical jargon. After a total of 270 searches, 52 websites met inclusion criteria. Mean SMOG grade was 10.6 (SD = 1.4) and 10.2 after adjustment. Mean Dale–Chall score was 9.1 (SD = 0.6), or Grades 13 to 15. Mean Fry graph coordinates (173 syllables, 5.1 sentences) corresponded to Grade 15. Seven sites (13%) were at or below the average adult reading level based on SMOG; none of the sites qualified based on the other tests. Readability was significantly poorer for academic versus commercial sites and for Health on the Net-certified versus noncertified sites. In conclusion, online information about BPH treatment markedly exceeds the reading comprehension of most U.S. adults. Websites maintained by academic institutions and certified by the Health on the Net standard have more difficult readability. Efforts to improve literacy with respect to urological health should target content readability independent of reliability. PMID:27903952

  12. How Readable Is BPH Treatment Information on the Internet? Assessing Barriers to Literacy in Prostate Health.

    PubMed

    Koo, Kevin; Yap, Ronald L

    2017-03-01

    Information about benign prostatic hyperplasia (BPH) has become increasingly accessible on the Internet. Though the ability to find such material is encouraging, its readability and impact on informing patient decision making are not known. To evaluate the readability of Internet-based information about BPH in the context of website ownership and Health on the Net certification, three search engines were queried daily for 1 month with BPH-related keywords. Website ownership data and Health on the Net certification status were verified. Three readability analyses were performed: SMOG test, Dale-Chall readability formula, and Fry readability graph. An adjusted SMOG calculation was performed to reduce overestimation from medical jargon. After a total of 270 searches, 52 websites met inclusion criteria. Mean SMOG grade was 10.6 ( SD = 1.4) and 10.2 after adjustment. Mean Dale-Chall score was 9.1 ( SD = 0.6), or Grades 13 to 15. Mean Fry graph coordinates (173 syllables, 5.1 sentences) corresponded to Grade 15. Seven sites (13%) were at or below the average adult reading level based on SMOG; none of the sites qualified based on the other tests. Readability was significantly poorer for academic versus commercial sites and for Health on the Net-certified versus noncertified sites. In conclusion, online information about BPH treatment markedly exceeds the reading comprehension of most U.S. adults. Websites maintained by academic institutions and certified by the Health on the Net standard have more difficult readability. Efforts to improve literacy with respect to urological health should target content readability independent of reliability.

  13. Readability of Patient Education Materials in Hand Surgery and Health Literacy Best Practices for Improvement.

    PubMed

    Hadden, Kristie; Prince, Latrina Y; Schnaekel, Asa; Couch, Cory G; Stephenson, John M; Wyrick, Theresa O

    2016-08-01

    This study aimed to update a portion of a 2008 study of patient education materials from the American Society for Surgery of the Hand Web site with new readability results, to compare the results to health literacy best practices, and to make recommendations to the field for improvement. A sample of 77 patient education documents were downloaded from the American Society for Surgery of the Hand Web site, handcare.org, and assessed for readability using 4 readability tools. Mean readability grade-level scores were derived. Best practices for plain language for written health materials were compiled from 3 government agency sources. The mean readability of the 77 patient education documents in the study was 9.3 grade level. This reading level is reduced from the previous study in 2008 in which the overall mean was 10.6; however, the current sample grade level still exceeds recommended readability according to best practices. Despite a small body of literature on the readability of patient education materials related to hand surgery and other orthopedic issues over the last 7 years, readability was not dramatically improved in our current sample. Using health literacy as a framework, improvements in hand surgery patient education may result in better understanding and better outcomes for patients seeing hand surgeons. Improved understanding of patient education materials related to hand surgery may improve preventable negative outcomes that are clinically significant as well as contribute to improved quality of life for patients. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Readability assessment of patient education materials on major otolaryngology association websites.

    PubMed

    Eloy, Jean Anderson; Li, Shawn; Kasabwala, Khushabu; Agarwal, Nitin; Hansberry, David R; Baredes, Soly; Setzen, Michael

    2012-11-01

    Various otolaryngology associations provide Internet-based patient education material (IPEM) to the general public. However, this information may be written above the fourth- to sixth-grade reading level recommended by the American Medical Association (AMA) and National Institutes of Health (NIH). The purpose of this study was to assess the readability of otolaryngology-related IPEMs on various otolaryngology association websites and to determine whether they are above the recommended reading level for patient education materials. Analysis of patient education materials from 9 major otolaryngology association websites. The readability of 262 otolaryngology-related IPEMs was assessed with 8 numerical and 2 graphical readability tools. Averages were evaluated against national recommendations and between each source using analysis of variance (ANOVA) with post hoc Tukey's honestly significant difference (HSD) analysis. Mean readability scores for each otolaryngology association website were compared. Mean website readability scores using Flesch Reading Ease test, Flesch-Kincaid Grade Level, Coleman-Liau Index, SMOG grading, Gunning Fog Index, New Dale-Chall Readability Formula, FORCAST Formula, New Fog Count Test, Raygor Readability Estimate, and the Fry Readability Graph ranged from 20.0 to 57.8, 9.7 to 17.1, 10.7 to 15.9, 11.6 to 18.2, 10.9 to 15.0, 8.6 to 16.0, 10.4 to 12.1, 8.5 to 11.8, 10.5 to 17.0, and 10.0 to 17.0, respectively. ANOVA results indicate a significant difference (P < .05) between the websites for each individual assessment. The IPEMs found on all otolaryngology association websites exceed the recommended fourth- to sixth-grade reading level.

  15. Readability of Trauma-Related Patient Education Materials From the American Academy of Orthopaedic Surgeons.

    PubMed

    Eltorai, Adam E M; P Thomas, Nathan; Yang, Heejae; Daniels, Alan H; Born, Christopher T

    2016-02-01

    According to the american medical association (AMA) and the national institutes of health (NIH), the recommended readability of patient education materials should be no greater than a sixth-grade reading level. The online patient education information produced by the american academy of orthopaedic surgeons (AAOS) may be too complicated for some patients to understand. This study evaluated whether the AAOS's online trauma-related patient education materials meet recommended readability guidelines for medical information. Ninety-nine articles from the "Broken Bones and Injuries" section of the AAOS-produced patient education website, orthoinfo.org, were analyzed for grade level readability using the Flesch-Kincaid formula, a widely-used and validated tool to evaluate the text reading level. Results for each webpage were compared to the AMA/NIH recommended sixth-grade reading level and the average reading level of U.S. adults (eighth-grade). The mean (SD) grade level readability for all patient education articles was 8.8 (1.1). All but three of the articles had a readability score above the sixth-grade level. The readability of the articles exceeded this level by an average of 2.8 grade levels (95% confidence interval, 2.6 - 3.0; P < 0.0001). Furthermore, the average readability of the articles exceeded the average reading skill level of U.S. adults (eighth grade) by nearly an entire grade level (95% confidence interval, 0.6-1.0; P < 0.0001). The majority of the trauma-related articles from the AAOS patient education website have readability levels that may make comprehension difficult for a substantial portion of the patient population.

  16. Assessment of online patient education materials from major ophthalmologic associations.

    PubMed

    Huang, Grace; Fang, Christina H; Agarwal, Nitin; Bhagat, Neelakshi; Eloy, Jean Anderson; Langer, Paul D

    2015-04-01

    Patients are increasingly using the Internet to supplement finding medical information, which can be complex and requires a high level of reading comprehension. Online ophthalmologic materials from major ophthalmologic associations should be written at an appropriate reading level. To assess ophthalmologic online patient education materials (PEMs) on ophthalmologic association websites and to determine whether they are above the reading level recommended by the American Medical Association and National Institutes of Health. Descriptive and correlational design. Patient education materials from major ophthalmology websites were downloaded from June 1, 2014, through June 30, 2014, and assessed for level of readability using 10 scales. The Flesch Reading Ease test, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook test, Coleman-Liau Index, Gunning Fog Index, New Fog Count, New Dale-Chall Readability Formula, FORCAST scale, Raygor Readability Estimate Graph, and Fry Readability Graph were used. Text from each article was pasted into Microsoft Word and analyzed using the software Readability Studio professional edition version 2012.1 for Windows. Flesch Reading Ease score, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook grade, Coleman-Liau Index score, Gunning Fog Index score, New Fog Count, New Dale-Chall Readability Formula score, FORCAST score, Raygor Readability Estimate Graph score, and Fry Readability Graph score. Three hundred thirty-nine online PEMs were assessed. The mean Flesch Reading Ease score was 40.7 (range, 17.0-51.0), which correlates with a difficult level of reading. The mean readability grade levels ranged as follows: 10.4 to 12.6 for the Flesch-Kincaid Grade Level; 12.9 to 17.7 for the Simple Measure of Gobbledygook test; 11.4 to 15.8 for the Coleman-Liau Index; 12.4 to 18.7 for the Gunning Fog Index; 8.2 to 16.0 for the New Fog Count; 11.2 to 16.0 for the New Dale-Chall Readability Formula; 10.9 to 12.5 for the FORCAST scale; 11.0 to 17.0 for the Raygor Readability Estimate Graph; and 12.0 to 17.0 for the Fry Readability Graph. Analysis of variance demonstrated a significant difference (P < .001) between the websites for each reading scale. Online PEMs on major ophthalmologic association websites are written well above the recommended reading level. Consideration should be given to revision of these materials to allow greater comprehension among a wider audience.

  17. Ultra-Structure database design methodology for managing systems biology data and analyses

    PubMed Central

    Maier, Christopher W; Long, Jeffrey G; Hemminger, Bradley M; Giddings, Morgan C

    2009-01-01

    Background Modern, high-throughput biological experiments generate copious, heterogeneous, interconnected data sets. Research is dynamic, with frequently changing protocols, techniques, instruments, and file formats. Because of these factors, systems designed to manage and integrate modern biological data sets often end up as large, unwieldy databases that become difficult to maintain or evolve. The novel rule-based approach of the Ultra-Structure design methodology presents a potential solution to this problem. By representing both data and processes as formal rules within a database, an Ultra-Structure system constitutes a flexible framework that enables users to explicitly store domain knowledge in both a machine- and human-readable form. End users themselves can change the system's capabilities without programmer intervention, simply by altering database contents; no computer code or schemas need be modified. This provides flexibility in adapting to change, and allows integration of disparate, heterogenous data sets within a small core set of database tables, facilitating joint analysis and visualization without becoming unwieldy. Here, we examine the application of Ultra-Structure to our ongoing research program for the integration of large proteomic and genomic data sets (proteogenomic mapping). Results We transitioned our proteogenomic mapping information system from a traditional entity-relationship design to one based on Ultra-Structure. Our system integrates tandem mass spectrum data, genomic annotation sets, and spectrum/peptide mappings, all within a small, general framework implemented within a standard relational database system. General software procedures driven by user-modifiable rules can perform tasks such as logical deduction and location-based computations. The system is not tied specifically to proteogenomic research, but is rather designed to accommodate virtually any kind of biological research. Conclusion We find Ultra-Structure offers substantial benefits for biological information systems, the largest being the integration of diverse information sources into a common framework. This facilitates systems biology research by integrating data from disparate high-throughput techniques. It also enables us to readily incorporate new data types, sources, and domain knowledge with no change to the database structure or associated computer code. Ultra-Structure may be a significant step towards solving the hard problem of data management and integration in the systems biology era. PMID:19691849

  18. Evaluation of the Readability of Dermatological Postoperative Patient Information Leaflets Across England.

    PubMed

    Hunt, William T N; McGrath, Emily J

    2016-06-01

    Postoperative patient information leaflets (PILs) provide important guidance to patients after skin surgery. Readability is a method of evaluating information for text comprehension. The recommended level for PIL readability is US grade ≤6. To evaluate the readability of public English dermatological postoperative PILs. All dermatology departments in England were requested to provide their postoperative PILs. Patient information leaflets were evaluated using Readability Studio (Oleander Software, Vandalia, OH). Two preselected parameters were also noted: whether the PIL was doctor or nurse-written, and whether the PIL was Information Standard hallmarked. Eighty-five of one hundred thirty (65.4%) of PILs were evaluated. Only 29.4% of the PILs were grade level ≤6 with Flesch-Kincaid. The mean readability levels were 7.8 for Flesch-Kincaid, 67 for Flesch reading ease, 10.5 for Simple Measure of Gobbledygook (SMOG), 9.4 for Gunning-Fog, 8 for Fry, and 9.8 for FORCAST. No instruments demonstrated a significant difference between doctor (6) and nurse-written (7) PILs. Two instruments found that the 3 Information Standard hallmarked PILs had a higher (harder) readability than ordinary PILs (n = 82) (Gunning-Fog, p = .029*; SMOG p = .049*). Most English postoperative dermatological PILs' readability levels exceed recommendations (US grade ≤6). Departmental PILs should be reviewed to ensure that they are comprehensible to their patients.

  19. Readability Assessment of Online Patient Education Material on Congestive Heart Failure

    PubMed Central

    2017-01-01

    Background Online health information is being used more ubiquitously by the general population. However, this information typically favors only a small percentage of readers, which can result in suboptimal medical outcomes for patients. Objective The readability of online patient education materials regarding the topic of congestive heart failure was assessed through six readability assessment tools. Methods The search phrase “congestive heart failure” was employed into the search engine Google. Out of the first 100 websites, only 70 were included attending to compliance with selection and exclusion criteria. These were then assessed through six readability assessment tools. Results Only 5 out of 70 websites were within the limits of the recommended sixth-grade readability level. The mean readability scores were as follows: the Flesch-Kincaid Grade Level (9.79), Gunning-Fog Score (11.95), Coleman-Liau Index (15.17), Simple Measure of Gobbledygook (SMOG) index (11.39), and the Flesch Reading Ease (48.87). Conclusion Most of the analyzed websites were found to be above the sixth-grade readability level recommendations. Efforts need to be made to better tailor online patient education materials to the general population. PMID:28656111

  20. An exploratory study of older adults' comprehension of printed cancer information: is readability a key factor?

    PubMed

    Friedman, Daniela B; Hoffman-Goetz, Laurie

    2007-01-01

    Printed cancer information often is written at or beyond high school reading levels, despite lower average literacy abilities of the public. The objectives of this exploratory study were twofold: (1) to evaluate older adults' comprehension of breast (BC), prostate (PC), and colorectal (CC) cancer information; and (2) to determine if comprehension of BC, PC, and CC information varies according to text readability. Comprehension of printed cancer resources was evaluated with 44 community-dwelling older adults using the Cloze procedure and recall questions. Participants' comprehension scores were compared with Simple Measure of Gobbledegook (SMOG) readability scores (

  1. Readability Approaches: Implications for Turkey

    ERIC Educational Resources Information Center

    Ulusoy, Mustafa

    2006-01-01

    Finding the right fit between students' reading ability and textbooks is very important for comprehension. Readability studies aim to analyse texts to find the right fit between students and texts. In this literature review, readability studies are classified under quantitative, qualitative and combined quantitative-qualitative readability…

  2. Readability assessment of online tracheostomy care resources.

    PubMed

    Kong, Keonho Albert; Hu, Amanda

    2015-02-01

    To assess the readability of online tracheostomy care resources. Cross-sectional study. Academic center. A Google search was performed for "tracheostomy care" in January 2014. The top 50 results were categorized into major versus minor websites and patient-oriented versus professional-oriented resources. These websites were evaluated with the following readability tools: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (GFOG). Readability scores for the websites were FRES 57.21 ± 16.71 (possible range = 0-100), FKGL 8.33 ± 2.84 (possible range = 3-12), SMOG 11.25 ± 2.49 (possible range = 3-19), and GFOG 11.43 ± 4.07 (possible range = 3-19). There was no significant difference in all 4 readability scores between major (n = 41) and minor (n = 9) websites. Professional-oriented websites (n = 19) had the following readability scores: FRES 40.77 ± 11.69, FKGL 10.93 ± 2.48, SMOG 13.29 ± 2.32, and GFOG 14.91 ± 3.98. Patient-oriented websites (n = 31) had the following readability scores: FRES 67.29 ± 9.91, FKGL 6.73 ± 1.61, SMOG 10.01 ± 1.64, and GFOG 9.30 ± 2.27. Professional-oriented websites had more difficult readability scores than patient-oriented websites for FRES (P < .00), FKGL (P < .00), SMOG (P < .00), and GFOG (P < .00). Online tracheostomy care resources were written at a level more difficult than the recommended fourth- to sixth-grade level for written health information. There was no significant difference in readability between major and minor websites. Professional-oriented websites were more difficult to read than patient-oriented websites. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  3. [Global analysis of the readability of the informed consent forms used in public hospitals of Spain].

    PubMed

    Mariscal-Crespo, M I; Coronado-Vázquez, M V; Ramirez-Durán, M V

    To analyse the readability of informed consent forms (ICF) used in Public Hospitals throughout Spain, with the aim of checking their function of providing comprehensive information to people who are making any health decision no matter where they are in Spain. A descriptive study was performed on a total of 11,339 ICF received from all over Spanish territory, of which 1617 ICF were collected from 4 web pages of Health Portal and the rest (9722) were received through email and/or telephone contact from March 2012 to February 2013. The readability level was studied using the Inflesz tool. A total of 372 ICF were selected and analysed using simple random sampling. The Inflesz scale and the Flesch-Szigriszt index were used to analyse the readability. The readability results showed that 62.4% of the ICF were rated as a "little difficult", the 23.4% as "normal", and the 13.4% were rated as "very difficult". The highest readability means using the Flesch index were scored in Andalusia with a mean of 56.99 (95% CI; 55.42-58.57) and Valencia with a mean of 51.93 (95% CI; 48.4-55.52). The lowest readability means were in Galicia with a mean of 40.77 (95% CI; 9.83-71.71) and Melilla, mean=41.82 (95% CI; 35.5-48.14). The readability level of Spanish informed consent forms must be improved because their scores using readability tools could not be classified in normal scales. Furthermore, there was very wide variability among Spanish ICF, which showed a lack of equity in information access among Spanish citizens. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. A survey of kidney disease and risk-factor information on the World Wide Web.

    PubMed

    Calderón, José Luis; Zadshir, Ashraf; Norris, Keith

    2004-11-11

    Chronic kidney disease (CKD) is epidemic, and informing those at risk is a national health priority. However, the discrepancy between the readability of health information and the literacy skills of those it targets is a recognized barrier to communicating health information that may promote good health outcomes. Because the World Wide Web has become one of the most important sources of health information, we sought to assess the readability of commonly available CKD information. Twelve highly cited English-language, kidney disease Web sites were identified with 4 popular search engines. Each Web site was reviewed for the availability of 6 domains of information germane to CKD and risk-factor information. We estimated readability scores with the Flesch-Kincaid and Flesch Reading Ease Index methods. The deviation of readability scores for CKD information from readability appropriate to average literacy skills and the limited literacy skills of vulnerable populations (low socioeconomic status, health disparities, and elderly) were calculated. Eleven Web sites met the inclusion criteria. Six of 11 sites provided information on all 6 domains of CKD and risk-factor information. Mean readability scores for all 6 domains of CKD information exceeded national average literacy skills and far exceeded the fifth-grade-level readability desired for informing vulnerable populations. Information about CKD and diabetes consistently had higher readability scores. Information on the World Wide Web about CKD and its risk factors may not be readable for comprehension by the general public, especially by underserved minority populations with limited literacy skills. Barriers to health communication may be important contributors to the rising CKD epidemic and disparities in CKD health status experienced by minority populations.

  5. Readability evaluation of Internet-based patient education materials related to the anesthesiology field.

    PubMed

    De Oliveira, Gildasio S; Jung, Michael; Mccaffery, Kirsten J; McCarthy, Robert J; Wolf, Michael S

    2015-08-01

    The main objective of the current investigation was to assess the readability of Internet-based patient education materials related to the field of anesthesiology. We hypothesized that the majority of patient education materials would not be written according to current recommended readability grade level. Online patient education materials describing procedures, risks, and management of anesthesia-related topics were identified using the search engine Google (available at www.google.com) using the terms anesthesia, anesthesiology, anesthesia risks, and anesthesia care. Cross-sectional evaluation. None. Assessments of content readability were performed using validated instruments (Flesch-Kincaid Grade Formulae, the Gunning Frequency of Gobbledygook, the New Dale-Chall Test, the Fry graph, and the Flesch Reading Ease score). Ninety-six Web sites containing Internet patient education materials (IPEMs) were evaluated. The median (interquartile range) readability grade level for all evaluated IPEMs was 13.5 (12.0-14.6). All the evaluated documents were classified at a greater readability level than the current recommended readability grade, P < .001. Readability grades were not significantly different among different IPEM sources. Assessment by the Flesch Reading Ease test classified all but 4 IPEMs as at least fairly difficult to read. Internet-based patient education materials related to the field of anesthesiology are currently written far above the recommended readability grade level. High complexity of written education materials likely limits access of information to millions of American patients. Redesign of online content of Web sites that provide patient education material regarding anesthesia could be an important step in improving access to information for patients with poor health literacy. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Readability levels of health pamphlets distributed in hospitals and health centres in Athens, Greece.

    PubMed

    Kondilis, B K; Akrivos, P D; Sardi, T A; Soteriades, E S; Falagas, M E

    2010-10-01

    Health literacy is important in the medical and social sciences due to its impact on behavioural and health outcomes. Nevertheless, little is known about it in Greece, including patients' level of understanding health brochures and pamphlets distributed in Greek hospitals and clinics. Observational study in the greater metropolitan area of Athens, Greece. Pamphlets and brochures written in the Greek language were collected from 17 hospitals and healthcare centres between the spring and autumn of 2006. Readability of pamphlets using the Flesch-Kincaid, Simple Measure of Gobbledygook (SMOG) and Fog methods was calculated based on a Greek readability software. Out of 70 pamphlets collected from 17 hospitals, 37 pamphlets met the criteria for the study. The average readability level of all scanned pamphlets was ninth to 10th grade, corresponding to a readability level of 'average'. A highly significant difference (P<0.001) was found between private and public hospitals using the Flesch-Kincaid and SMOG readability scales. Pamphlets from private hospitals were one grade more difficult than those from public hospitals. Approximately 43.7% of the Greek population aged ≥20 years would not be able to comprehend the available pamphlets, which were found to have an average readability level of ninth to 10th grade. Further research examining readability levels in the context of health literacy in Greece is warranted. This effort paves the way for additional research in the field of readability levels of health pamphlets in the Greek language, the sources of health information, and the level of understanding of key health messages by the population. Copyright © 2010 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  7. Color pictorial serpentine halftone for secure embedded data

    NASA Astrophysics Data System (ADS)

    Curry, Douglas N.

    1998-04-01

    This paper introduces a new rotatable glyph shape for trusted printing applications that has excellent image rendering, data storage and counterfeit deterrence properties. Referred to as a serpentine because it tiles into a meandering line screen, it can produce high quality images independent of its ability to embed data. The hafltone cell is constructed with hyperbolic curves to enhance its dynamic range, and generates low distortion because of rotational tone invariance with its neighbors. An extension to the process allows the data to be formatted into human readable text patterns, viewable with a magnifying glass, and therefore not requiring input scanning. The resultant embedded halftone patterns can be recognized as simple numbers (0 - 9) or alphanumerics (a - z). The pattern intensity can be offset from the surrounding image field intensity, producing a watermarking effect. We have been able to embed words such as 'original' or license numbers into the background halftone pattern of images which can be readily observed in the original image, and which conveniently disappear upon copying. We have also embedded data blocks with self-clocking codes and error correction data which are machine-readable. Finally, we have successfully printed full color images with both the embedded data and text, simulating a trusted printing application.

  8. Readability, Suitability and Health Content Assessment of Cancer Screening Announcements in Municipal Newspapers in Japan.

    PubMed

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Hiroko; Kiuchi, Takahiro

    2015-01-01

    The objective of this study was to assess the readability, suitability, and health content of cancer screening information in municipal newspapers in Japan. Suitability Assessment of Materials (SAM) and the framework of Health Belief Model (HBM) were used for assessment of municipal newspapers that were published in central Tokyo (23 wards) from January to December 2013. The mean domain SAM scores of content, literacy demand, and layout/typography were considered superior. The SAM scores of interaction with readers, an indication of the models of desirable actions, and elaboration to enhance readers' self-efficacy were low. According to the HBM coding, messages of medical/clinical severity, of social severity, of social benefits, and of barriers of fear were scarce. The articles were generally well written and suitable. However, learning stimulation/motivation was scarce and the HBM constructs were not fully addressed. Articles can be improved to motivate readers to obtain cancer screening by increasing interaction with readers, introducing models of desirable actions and devices to raise readers' self-efficacy, and providing statements of perceived barriers of fear for pain and time constraints, perceived severity, and social benefits and losses.

  9. Word add-in for ontology recognition: semantic enrichment of scientific literature

    PubMed Central

    2010-01-01

    Background In the current era of scientific research, efficient communication of information is paramount. As such, the nature of scholarly and scientific communication is changing; cyberinfrastructure is now absolutely necessary and new media are allowing information and knowledge to be more interactive and immediate. One approach to making knowledge more accessible is the addition of machine-readable semantic data to scholarly articles. Results The Word add-in presented here will assist authors in this effort by automatically recognizing and highlighting words or phrases that are likely information-rich, allowing authors to associate semantic data with those words or phrases, and to embed that data in the document as XML. The add-in and source code are publicly available at http://www.codeplex.com/UCSDBioLit. Conclusions The Word add-in for ontology term recognition makes it possible for an author to add semantic data to a document as it is being written and it encodes these data using XML tags that are effectively a standard in life sciences literature. Allowing authors to mark-up their own work will help increase the amount and quality of machine-readable literature metadata. PMID:20181245

  10. Readability and writing style analysis of selected allied health professional journals.

    PubMed

    Hedl, J J; Glazer-Waldman, H R; Parker, H J; Hopkins, K M

    1991-01-01

    Using US Department of Defense text sampling procedures, nine allied health journals were analyzed for readability and selected writing style indices via Right Writer, a commercial software program. Two indices of readability were computed for each journal as were several indices of writing style. The computed readability ranged from 13.0 to 15.4, depending upon the journal in question. Two journals showed the highest levels of readability (15.4) compared to the other seven journals. The writing style analyses indicated generally normal ranges for the descriptive and jargon indices, but seven journals showed below recommended strength indices. Sentence structure analyses indicated a need to reduce sentence structure complexity. Implications for journal editors and authors are discussed.

  11. ClearTK 2.0: Design Patterns for Machine Learning in UIMA

    PubMed Central

    Bethard, Steven; Ogren, Philip; Becker, Lee

    2014-01-01

    ClearTK adds machine learning functionality to the UIMA framework, providing wrappers to popular machine learning libraries, a rich feature extraction library that works across different classifiers, and utilities for applying and evaluating machine learning models. Since its inception in 2008, ClearTK has evolved in response to feedback from developers and the community. This evolution has followed a number of important design principles including: conceptually simple annotator interfaces, readable pipeline descriptions, minimal collection readers, type system agnostic code, modules organized for ease of import, and assisting user comprehension of the complex UIMA framework. PMID:29104966

  12. ClearTK 2.0: Design Patterns for Machine Learning in UIMA.

    PubMed

    Bethard, Steven; Ogren, Philip; Becker, Lee

    2014-05-01

    ClearTK adds machine learning functionality to the UIMA framework, providing wrappers to popular machine learning libraries, a rich feature extraction library that works across different classifiers, and utilities for applying and evaluating machine learning models. Since its inception in 2008, ClearTK has evolved in response to feedback from developers and the community. This evolution has followed a number of important design principles including: conceptually simple annotator interfaces, readable pipeline descriptions, minimal collection readers, type system agnostic code, modules organized for ease of import, and assisting user comprehension of the complex UIMA framework.

  13. Allotments from federal employees. Interim rule with request for comments.

    PubMed

    2006-11-17

    The Office of Personnel Management (OPM) is issuing interim regulations dealing with the use of OPM's allotment authority to allow for pretax salary reductions as part of OPM's flexible benefits plan. Using an allotment from an employee's pay to the employing agency allows certain payments (e.g., employee health insurance premiums, contributions to a flexible spending arrangement, and contributions to a health savings account) to be paid with pretax dollars, as provided under section 125 of the Internal Revenue Code. In addition, these regulations include certain policy clarifications and changes to make the regulations more readable.

  14. An introduction to scripting in Ruby for biologists.

    PubMed

    Aerts, Jan; Law, Andy

    2009-07-16

    The Ruby programming language has a lot to offer to any scientist with electronic data to process. Not only is the initial learning curve very shallow, but its reflection and meta-programming capabilities allow for the rapid creation of relatively complex applications while still keeping the code short and readable. This paper provides a gentle introduction to this scripting language for researchers without formal informatics training such as many wet-lab scientists. We hope this will provide such researchers an idea of how powerful a tool Ruby can be for their data management tasks and encourage them to learn more about it.

  15. An analysis of thermal response factors and how to reduce their computational time requirement

    NASA Technical Reports Server (NTRS)

    Wiese, M. R.

    1982-01-01

    Te RESFAC2 version of the Thermal Response Factor Program (RESFAC) is the result of numerous modifications and additions to the original RESFAC. These modifications and additions have significantly reduced the program's computational time requirement. As a result of this work, the program is more efficient and its code is both readable and understandable. This report describes what a thermal response factor is; analyzes the original matrix algebra calculations and root finding techniques; presents a new root finding technique and streamlined matrix algebra; supplies ten validation cases and their results.

  16. Readability in 1968.

    ERIC Educational Resources Information Center

    Bormuth, John R., Ed.

    This bulletin presents four papers on how to control, manipulate, and predict the readability of printed materials. The first paper describes trends in readability brought about by research tools developed by psychologists and linguists. The second paper explores the effects of word frequency in printed materials on comprehension and concludes…

  17. Textbooks in Management, Marketing and Finance: An Analysis of Readability.

    ERIC Educational Resources Information Center

    Gallagher, Daniel J.; Thompson, G. Rodney

    1982-01-01

    Examines the readability of texts in basic junior level college courses in the fields of management, marketing, and finance. The readability model is described, along with its application and results. Specific texts and how they fared are listed in accompanying tables. (CT)

  18. Readability and Recall of Short Prose Passages: A Theoretical Analysis.

    ERIC Educational Resources Information Center

    Miller, James R.; Kintsch, Walter

    1980-01-01

    To support the view of readability as an interaction between a text and the reader's prose-processing capabilities, this article applies an extended and formalized version of the Kintch and van Dijk prose-processing model to 20 texts of varying readability. (Author/GSK)

  19. Readability assessment of the American Rhinologic Society patient education materials.

    PubMed

    Kasabwala, Khushabu; Misra, Poonam; Hansberry, David R; Agarwal, Nitin; Baredes, Soly; Setzen, Michael; Eloy, Jean Anderson

    2013-04-01

    The extensive amount of medical literature available on the Internet is frequently accessed by patients. To effectively contribute to healthcare decision-making, these online resources should be worded at a level that is readable by any patient seeking information. The American Medical Association and National Institutes of Health recommend the readability of patient information material should be between a 4th to 6th grade level. In this study, we evaluate the readability of online patient education information available from the American Rhinologic Society (ARS) website using 9 different assessment tools that analyze the materials for reading ease and grade level of the target audience. Online patient education material from the ARS was downloaded in February 2012 and assessed for level of readability using the Flesch Reading Ease, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook (SMOG) Grading, Coleman-Liau Index, Gunning-Fog Index, FORCAST formula, Raygor Readability Estimate, the Fry Graph, and the New Dale-Chall Readability Formula. Each article was pasted as plain text into a Microsoft® Word® document and each subsection was analyzed using the software package Readability Studio Professional Edition Version 2012.1. All healthcare education materials assessed were written between a 9th grade and graduate reading level and were considered "difficult" to read by the assessment scales. Online patient education materials on the ARS website are written above the recommended 6th grade level and may require revision to make them easily understood by a broader audience. © 2013 ARS-AAOA, LLC.

  20. Quality and Readability of English-Language Internet Information for Voice Disorders.

    PubMed

    Dueppen, Abigail J; Bellon-Harn, Monica L; Radhakrishnan, Nandhakumar; Manchaiah, Vinaya

    2017-12-15

    The purpose of this study is to evaluate the readability and quality of English-language Internet information related to vocal hygiene, vocal health, and prevention of voice disorders. This study extends recent work because it evaluates readability, content quality, and website origin across broader search criteria than previous studies evaluating online voice material. Eighty-five websites were aggregated using five different country-specific search engines. Websites were then analyzed using quality and readability assessments. The entire web page was evaluated; however, no information or links beyond the first page was reviewed. Statistical calculations were employed to examine website ratings, differences between website origin and quality and readability scores, and correlations between readability instruments. Websites exhibited acceptable quality as measured by the DISCERN. However, only one website obtained the Health On the Net certification. Significant differences in quality were found among website origin, with government websites receiving higher quality ratings. Approximate educational levels required to comprehend information on the websites ranged from 8 to 9 years of education. Significant differences were found between website origin and readability measures with higher levels of education required to understand information on websites of nonprofit organizations. Current vocal hygiene, vocal health, and prevention of voice disorders websites were found to exhibit acceptable levels of quality and readability. However, highly rated Internet information related to voice care should be made more accessible to voice clients through Health On the Net certification. Published by Elsevier Inc.

  1. Are Online Zenker's Diverticulum Materials Readable and Understandable?

    PubMed

    Balakrishnan, Vini; Chandy, Zachariah; Verma, Sunil P

    2016-11-01

    Patients use a multitude of resources to learn about Zenker's diverticulum (ZD). The objectives of this study were to assess the readability and understandability of online materials on ZD, evaluate them against the existing criteria, and investigate the relationship between readability and understandability. The first 50 webpages from an online search for ZD were analyzed. Twenty-one webpages had materials intended for patients and were included in the study. The patient education materials (PEMs) were analyzed using 6 readability tools. Four individuals used the Patient Education Materials Evaluation Tool (PEMAT) to assess the understandability. Fleiss κ interrater reliability analysis determined consistency among the raters. Finally, Pearson correlation coefficient analyzed the relationship between readability and understandability. The reading grade level of the materials reviewed ranged from 10th to 16th grade while the understandability ranged from 31% to 74%. Correlation analysis demonstrated a strong negative correlation between readability and understandability (r = -0.62, P < .05). Fleiss' κ interrater reliability for the raters demonstrated substantial agreement between the 4 raters (κ = 0.64). Online PEMs pertaining to ZD are written well above the recommended reading level. Materials written at a lower reading level are more understandable. A wide range of understandability exists among materials with identical reading grade levels. Health care providers need to create new PEMs for ZD that are available online that are both readable and understandable. The PEMAT and readability formulas can provide a framework for authors to create these materials. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  2. Unsuitable readability levels of patient information pertaining to dementia and related diseases: a comparative analysis.

    PubMed

    Weih, Markus; Reinhold, Angelika; Richter-Schmidinger, Tanja; Sulimma, Anne-Kathrin; Klein, Harald; Kornhuber, Johannes

    2008-12-01

    Our study investigated the readability of printed material about dementia that is offered to patients and caregivers. Comparisons of various brochures (at least three standard pages in length) on dementia and related disorders were made using automated measuring by the SMOG readability index grade. 118 brochures were assessed (25 in English, 93 in German), for which the mean readability was found to be high school/college level as measured by the SMOG readability index (grade 13.6 +/- 1.8). No differences in readability were observed between materials produced by pharmaceutical companies and other sources. Furthermore, recently published brochures were not more readable than older ones. Shorter brochures, English brochures and those containing medical facts were easier to read than longer ones, those written in German or brochures primarily addressing psychosocial care/social issues. The sentence length was above the 20 word recommendation in 25% of the brochures. The average font size of the brochure texts was small (mean font size 11.1 +/- 1.6 point) with only 25% of brochures having a font size of 12 or more, as recommended. Written patient information and educational material of more than three standard pages is often published at unsuitably high readability levels using small fonts. Information material about dementia should be designed and tested prior to distribution among patients and caregivers. Future studies should address material shorter than three pages and material for younger caregivers.

  3. Readability as a Factor in Magazine Ad Copy Recall.

    ERIC Educational Resources Information Center

    Wesson, David A.

    1989-01-01

    Examines the relationship between advertising copy readability and advertising effectiveness. Finds that recall is improved when the copy style is either fairly easy or fairly hard to read. Suggests the value of considering copy readability as a potential contributor, though a minor one, to the success of magazine advertising. (RS)

  4. Readability Levels of the 1975 Third Grade Macmillan Basal Readers.

    ERIC Educational Resources Information Center

    McKinney, Ernestine Williams

    1983-01-01

    Analysis of third-grade books in the New Macmillan Reading Program reveals that the books exceeded the publisher's designation of readability and did not progress in difficulty from easy to more difficult. Findings suggest the need for more complete and reliable information from publishers concerning textbook readability. (FL)

  5. Varying Readability of Science-Based Text in Elementary Readers: Challenges for Teachers

    ERIC Educational Resources Information Center

    Gallagher, Tiffany L.; Fazio, Xavier; Gunning, Thomas G.

    2012-01-01

    This investigation compared readability formulae to publishers' identified reading levels in science-based elementary readers. Nine well-established readability indices were calculated and comparisons were made with the publishers' identified grade designations and between different genres of text. Results revealed considerable variance among the…

  6. The Effect of Technology-Based Altered Readability Levels on Struggling Readers' Science Comprehension

    ERIC Educational Resources Information Center

    Marino, Matthew T.; Coyne, Michael; Dunn, Michael

    2010-01-01

    This article reports findings from a study examining how altered readability levels affected struggling readers' (N = 288) comprehension of scientific concepts and vocabulary. Specifically, the researchers were interested in learning what effect altered readability levels have when low ability readers participate in a technology-based science…

  7. Readability of Questionnaires Assessing Listening Difficulties Associated with (Central) Auditory Processing Disorders

    ERIC Educational Resources Information Center

    Atcherson, Samuel R.; Richburg, Cynthia M.; Zraick, Richard I.; George, Cassandra M.

    2013-01-01

    Purpose: Eight English-language, student- or parent proxy-administered questionnaires for (central) auditory processing disorders, or (C)APD, were analyzed for readability. For student questionnaires, readability levels were checked against the approximate reading grade levels by intended administration age per the questionnaires' developers. For…

  8. Measuring the Readability of Elementary Algebra Using the Cloze Technique.

    ERIC Educational Resources Information Center

    Kulm, Gerald

    The relationship to readability of ten variables characterizing structural properties of mathematical prose was investigated in elementary algebra textbooks. Readability was measured by algebra student's responses to two forms of cloze tests. Linear and currilinear correlations were calculated between each structural variable and the cloze test.…

  9. An analysis of the readability of patient information and consent forms used in research studies in anaesthesia in Australia and New Zealand.

    PubMed

    Taylor, H E; Bramley, D E P

    2012-11-01

    The provision of written information is a component of the informed consent process for research participants. We conducted a readability analysis to test the hypothesis that the language used in patient information and consent forms in anaesthesia research in Australia and New Zealand does not meet the readability standards or expectations of the Good Clinical Practice Guidelines, the National Health and Medical Research Council in Australia and the Health Research Council of New Zealand. We calculated readability scores for 40 patient information and consent forms using the Simple Measure of Gobbledygook and Flesch-Kincaid formulas. The mean grade level of patient information and consent forms when using the Simple Measure of Gobbledygook and Flesch-Kincaid readability formulas was 12.9 (standard deviation of 0.8, 95% confidence interval 12.6 to 13.1) and 11.9 (standard deviation 1.1, 95% confidence interval 11.6 to 12.3), respectively. This exceeds the average literacy and comprehension of the general population in Australia and New Zealand. Complex language decreases readability and negatively impacts on the informed consent process. Care should be exercised when providing written information to research participants to ensure language and readability is appropriate for the audience.

  10. Readability of patient information and consent documents in rheumatological studies.

    PubMed

    Hamnes, Bente; van Eijk-Hustings, Yvonne; Primdahl, Jette

    2016-07-16

    Before participation in medical research an informed consent must be obtained. This study investigates whether the readability of patient information and consent documents (PICDs) corresponds to the average educational level of participants in rheumatological studies in the Netherlands, Denmark, and Norway. 24 PICDs from studies were collected and readability was assessed independently using the Gunning's Fog Index (FOG) and Simple Measure of Gobbledygook (SMOG) grading. The mean score for the FOG and SMOG grades were 14.2 (9.0-19.0) and 14.2 (12-17) respectively. The mean FOG and SMOG grades were 12.7 and 13.3 in the Dutch studies, 15.0 and 14.9 in the Danish studies, and 14.6 and 14.3 in the Norwegian studies, respectively. Out of the 2865 participants, more than 57 % had a lower educational level than the highest readability score calculated in the individual study. As the readability level of the PICDs did not match the participants' educational level, consent may not have been valid, as the participants may have had a limited understanding of what they agreed to participate in. There should be more focus on the readability of PICDs. National guidelines for how to write clear and unambiguous PICDs in simple and easily understandable language could increase the focus on the readability of PICD.

  11. Constructing and validating readability models: the method of integrating multilevel linguistic features with machine learning.

    PubMed

    Sung, Yao-Ting; Chen, Ju-Ling; Cha, Ji-Her; Tseng, Hou-Chiang; Chang, Tao-Hsing; Chang, Kuo-En

    2015-06-01

    Multilevel linguistic features have been proposed for discourse analysis, but there have been few applications of multilevel linguistic features to readability models and also few validations of such models. Most traditional readability formulae are based on generalized linear models (GLMs; e.g., discriminant analysis and multiple regression), but these models have to comply with certain statistical assumptions about data properties and include all of the data in formulae construction without pruning the outliers in advance. The use of such readability formulae tends to produce a low text classification accuracy, while using a support vector machine (SVM) in machine learning can enhance the classification outcome. The present study constructed readability models by integrating multilevel linguistic features with SVM, which is more appropriate for text classification. Taking the Chinese language as an example, this study developed 31 linguistic features as the predicting variables at the word, semantic, syntax, and cohesion levels, with grade levels of texts as the criterion variable. The study compared four types of readability models by integrating unilevel and multilevel linguistic features with GLMs and an SVM. The results indicate that adopting a multilevel approach in readability analysis provides a better representation of the complexities of both texts and the reading comprehension process.

  12. Readability of websites containing information on dental implants.

    PubMed

    Jayaratne, Yasas S N; Anderson, Nina K; Zwahlen, Roger A

    2014-12-01

    It is recommended that health-related materials for patients be written at sixth grade level or below. Many websites oriented toward patient education about dental implants are available, but the readability of these sites has not been evaluated. To assess readability of patient-oriented online information on dental implants. Websites containing patient-oriented information on dental implants were retrieved using the Google search engine. Individual and mean readability/grade levels were calculated using standardized formulas. Readability of each website was classified as easy (≤ 6th-grade level) or difficult (≥ 10th grade level). Thirty nine websites with patient-oriented information on dental implant were found. The average readability grade level of these websites was 11.65 ± 1.36. No website scored at/below the recommended 6th grade level. Thirty four of 39 websites (87.18%) were difficult to read. The number of characters, words, and sentences on these sites varied widely. All patient-oriented websites on dental implants scored above the recommended grade level, and majority of these sites were "difficult" in their readability. There is a dire need to create patient information websites on implants, which the majority can read. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Validation of the new diagnosis grouping system for pediatric emergency department visits using the International Classification of Diseases, 10th Revision.

    PubMed

    Lee, Jin Hee; Hong, Ki Jeong; Kim, Do Kyun; Kwak, Young Ho; Jang, Hye Young; Kim, Hahn Bom; Noh, Hyun; Park, Jungho; Song, Bongkyu; Jung, Jae Yun

    2013-12-01

    A clinically sensible diagnosis grouping system (DGS) is needed for describing pediatric emergency diagnoses for research, medical resource preparedness, and making national policy for pediatric emergency medical care. The Pediatric Emergency Care Applied Research Network (PECARN) developed the DGS successfully. We developed the modified PECARN DGS based on the different pediatric population of South Korea and validated the system to obtain the accurate and comparable epidemiologic data of pediatric emergent conditions of the selected population. The data source used to develop and validate the modified PECARN DGS was the National Emergency Department Information System of South Korea, which was coded by the International Classification of Diseases, 10th Revision (ICD-10) code system. To develop the modified DGS based on ICD-10 code, we matched the selected ICD-10 codes with those of the PECARN DGS by the General Equivalence Mappings (GEMs). After converting ICD-10 codes to ICD-9 codes by GEMs, we matched ICD-9 codes into PECARN DGS categories using the matrix developed by PECARN group. Lastly, we conducted the expert panel survey using Delphi method for the remaining diagnosis codes that were not matched. A total of 1879 ICD-10 codes were used in development of the modified DGS. After 1078 (57.4%) of 1879 ICD-10 codes were assigned to the modified DGS by GEM and PECARN conversion tools, investigators assigned each of the remaining 801 codes (42.6%) to DGS subgroups by 2 rounds of electronic Delphi surveys. And we assigned the remaining 29 codes (4%) into the modified DGS at the second expert consensus meeting. The modified DGS accounts for 98.7% and 95.2% of diagnoses of the 2008 and 2009 National Emergency Department Information System data set. This modified DGS also exhibited strong construct validity using the concepts of age, sex, site of care, and seasons. This also reflected the 2009 outbreak of H1N1 influenza in Korea. We developed and validated clinically feasible and sensible DGS system for describing pediatric emergent conditions in Korea. The modified PECARN DGS showed good comprehensiveness and demonstrated reliable construct validity. This modified DGS based on PECARN DGS framework may be effectively implemented for research, reporting, and resource planning in pediatric emergency system of South Korea.

  14. Languages for artificial intelligence: Implementing a scheduler in LISP and in Ada

    NASA Technical Reports Server (NTRS)

    Hays, Dan

    1988-01-01

    A prototype scheduler for space experiments originally programmed in a dialect of LISP using some of the more traditional techniques of that language, was recast using an object-oriented LISP, Common LISP with Flavors on the Symbolics. This object-structured version was in turn partially implemented in Ada. The Flavors version showed a decided improvement in both speed of execution and readability of code. The recasting into Ada involved various practical problems of implementation as well as certain challenges of reconceptualization in going from one language to the other. Advantages were realized, however, in greater clarity of the code, especially where more standard flow of control was used. This exercise raised issues about the influence of programming language on the design of flexible and sensitive programs such as schedule planners, and called attention to the importance of factors external to the languages themselves such as system embeddedness, hardware context, and programmer practice.

  15. System and method for embedding emotion in logic systems

    NASA Technical Reports Server (NTRS)

    Curtis, Steven A. (Inventor)

    2012-01-01

    A system, method, and computer readable-media for creating a stable synthetic neural system. The method includes training an intellectual choice-driven synthetic neural system (SNS), training an emotional rule-driven SNS by generating emotions from rules, incorporating the rule-driven SNS into the choice-driven SNS through an evolvable interface, and balancing the emotional SNS and the intellectual SNS to achieve stability in a nontrivial autonomous environment with a Stability Algorithm for Neural Entities (SANE). Generating emotions from rules can include coding the rules into the rule-driven SNS in a self-consistent way. Training the emotional rule-driven SNS can occur during a training stage in parallel with training the choice-driven SNS. The training stage can include a self assessment loop which measures performance characteristics of the rule-driven SNS against core genetic code. The method uses a stability threshold to measure stability of the incorporated rule-driven SNS and choice-driven SNS using SANE.

  16. Invisible Security Ink Based on Water-Soluble Graphitic Carbon Nitride Quantum Dots.

    PubMed

    Song, Zhiping; Lin, Tianran; Lin, Lihua; Lin, Sen; Fu, Fengfu; Wang, Xinchen; Guo, Liangqia

    2016-02-18

    Stimuli-responsive photoluminescent (PL) materials have been widely used as fluorescent ink for data security applications. However, traditional fluorescent inks are limited in maintaining the secrecy of information because the inks are usually visible by naked eyes either under ambient light or UV-light illumination. Here, we introduced metal-free water-soluble graphitic carbon nitride quantum dots (g-CNQDs) as invisible security ink for information coding, encryption, and decryption. The information written by the g-CNQDs is invisible in ambient light and UV light, but it can be readable by a fluorescence microplate reader. Moreover, the information can be encrypted and decrypted by using oxalic acid and sodium bicarbonate as encryption reagent and decryption reagent, respectively. Our findings provide new opportunities for high-level information coding and protection by using water-soluble g-CNQDs as invisible security ink. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A Comparison of Readability in Science-Based Texts: Implications for Elementary Teachers

    ERIC Educational Resources Information Center

    Gallagher, Tiffany; Fazio, Xavier; Ciampa, Katia

    2017-01-01

    Science curriculum standards were mapped onto various texts (literacy readers, trade books, online articles). Statistical analyses highlighted the inconsistencies among readability formulae for Grades 2-6 levels of the standards. There was a lack of correlation among the readability measures, and also when comparing different text sources. Online…

  18. Survey of Commercially Available Computer-Readable Bibliographic Data Bases.

    ERIC Educational Resources Information Center

    Schneider, John H., Ed.; And Others

    This document contains the results of a survey of 94 U. S. organizations, and 36 organizations in other countries that were thought to prepare machine-readable data bases. Of those surveyed, 55 organizations (40 in U. S., 15 in other countries) provided completed camera-ready forms describing 81 commercially available, machine-readable data bases…

  19. Readability and Its Effects on Reading Rate, Subjective Judgments of Comprehensibility and Comprehension.

    ERIC Educational Resources Information Center

    Coke, Esther U.

    Prose passages read aloud or silently were rated for pronounceability and comprehensibility. The relationships of text-derived readability indices to reading rate, comprehensibility ratings and comprehension test scores were explored. Reading rate in syllables per minute was unrelated to readability. The high correlation between rate in words per…

  20. 77 FR 7 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... requirements will facilitate the use of a labeling system using machine-readable information that would be... components. Furthermore, we proposed the use of a labeling system using machine-readable information that...; Facilitates the use of a labeling system using machine- readable information that would be acceptable as a...

  1. A Framework for Readability Research.

    ERIC Educational Resources Information Center

    Harris, Albert J.; Jacobson, Milton D.

    There is a need for basic readability research and for an easily applied and accurate new readability formula. Two steps taken toward the development of such a formula are the revision of a vocabulary list for primary grades and the combination of reading exercises given at different grade levels into a single scale of ascending difficulty. Much…

  2. How Readability and Topic Incidence Relate to Performance on Mathematics Story Problems in Computer-Based Curricula

    ERIC Educational Resources Information Center

    Walkington, Candace; Clinton, Virginia; Ritter, Steven N.; Nathan, Mitchell J.

    2015-01-01

    Solving mathematics story problems requires text comprehension skills. However, previous studies have found few connections between traditional measures of text readability and performance on story problems. We hypothesized that recently developed measures of readability and topic incidence measured by text-mining tools may illuminate associations…

  3. Computational Text Analysis: A More Comprehensive Approach to Determine Readability of Reading Materials

    ERIC Educational Resources Information Center

    Aziz, Anealka; Fook, Chan Yuen; Alsree, Zubaida

    2010-01-01

    Reading materials are considered having high readability if readers are interested to read the materials, understand the content of the materials and able to read the materials fluently. In contrast, reading materials with low readability discourage readers from reading the materials, create difficulties for readers to understand the content of…

  4. Analysis of Readability and Interest of Marketing Education Textbooks: Implications for Special Needs Learners.

    ERIC Educational Resources Information Center

    Jones, Karen H.; And Others

    1993-01-01

    The readability, reading ease, interest level, and writing style of 20 current textbooks in secondary marketing education were evaluated. Readability formulas consistently identified lower reading levels for special needs education, human interest scores were not very reliable information sources, and writing style was also a weak variable. (JOW)

  5. 6 CFR 37.19 - Machine readable technology on the driver's license or identification card.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., States must use the ISO/IEC 15438:2006(E) Information Technology—Automatic identification and data... 6 Domestic Security 1 2011-01-01 2011-01-01 false Machine readable technology on the driver's..., Verification, and Card Issuance Requirements § 37.19 Machine readable technology on the driver's license or...

  6. 6 CFR 37.19 - Machine readable technology on the driver's license or identification card.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., States must use the ISO/IEC 15438:2006(E) Information Technology—Automatic identification and data... 6 Domestic Security 1 2010-01-01 2010-01-01 false Machine readable technology on the driver's..., Verification, and Card Issuance Requirements § 37.19 Machine readable technology on the driver's license or...

  7. Text Readability and Intuitive Simplification: A Comparison of Readability Formulas

    ERIC Educational Resources Information Center

    Crossley, Scott A.; Allen, David B.; McNamara, Danielle S.

    2011-01-01

    Texts are routinely simplified for language learners with authors relying on a variety of approaches and materials to assist them in making the texts more comprehensible. Readability measures are one such tool that authors can use when evaluating text comprehensibility. This study compares the Coh-Metrix Second Language (L2) Reading Index, a…

  8. Can Readability Formulas Be Used to Successfully Gauge Difficulty of Reading Materials?

    ERIC Educational Resources Information Center

    Begeny, John C.; Greene, Diana J.

    2014-01-01

    A grade level of reading material is commonly estimated using one or more readability formulas, which purport to measure text difficulty based on specified text characteristics. However, there is limited direction for teachers and publishers regarding which readability formulas (if any) are appropriate indicators of actual text difficulty. Because…

  9. The Readability of Information Literacy Content on Academic Library Web Sites

    ERIC Educational Resources Information Center

    Lim, Adriene

    2010-01-01

    This article reports on a study addressing the readability of content on academic libraries' Web sites, specifically content intended to improve users' information literacy skills. Results call for recognition of readability as an evaluative component of text in order to better meet the needs of diverse user populations. (Contains 8 tables.)

  10. A Comparison of Two Methods of Assessing Textbook Readability of Selected College Level Electronics Textbooks.

    ERIC Educational Resources Information Center

    Froelich, Donald Max

    Fifty-eight students enrolled in basic electronics courses from three state colleges in Missouri, were involved in comparing the cloze readability technique with the Flesch Reading Ease Formula to ascertain the effectiveness of each in assessing the readability of selected college level electronics textbooks. Pearson product-moment correlations…

  11. Readability of Brochures Produced by State of Florida.

    ERIC Educational Resources Information Center

    Christ, William G.; Pharr, Paula

    1980-01-01

    A study of the readability of governmental pamphlets produced by the State of Florida, based on the use of the Flesch Reading Ease Formula and the Dale-Chall Formula, suggests that if a seventh or eighth grade readability level is considered an appropriate standard for public information brochures, the brochures tested may be too complex…

  12. Quality and readability assessment of websites related to recurrent respiratory papillomatosis

    PubMed Central

    de Groot, Olivier S.D.; Dikkers, Frederik G.

    2017-01-01

    Objective Recurrent respiratory papillomatosis (RRP) is a rare disease for which a limited number of information sources for patients exist. The role of the Internet in the patient–physician relationship is increasing. More and more patients search for online health information, which should be of good quality and easy readable. The study aim was to investigate the quality and readability of English online health information about RRP. Study Design Quality and readability assessment of online information. Methods Relevant information was collected using three different search engines and seven different search terms. Quality was assessed with the DISCERN instrument. The Flesch Reading Ease Score (FRES) and average grade level (AGL) were determined to measure readability of the English websites. Results Fifty‐one English websites were included. The mean DISCERN score of the websites is 28.1 ± 9.7 (poor quality); the mean FRES is 41.3 ± 14.9 (difficult to read); and the mean AGL is 12.6 ± 2.3. Conclusion The quality and readability of English websites about RRP is alarmingly poor. Level of Evidence NA. Laryngoscope, 127:2293–2297, 2017 PMID:28233911

  13. MDA and AAEM informational brochures: can patients read them?

    PubMed

    Galloway, Gloria; Murphy, Peggy; Chesson, Andrew L; Martinez, Karen

    2003-06-01

    The purpose of this study was to assess patient literacy and the readability of patient education brochures from the American Academy of Electrodiagnostic Medicine and Muscular Dystrophy Association. Materials with the appropriate readability and suitability are more likely to provide instruction patients will understand. The readability of the brochure was assessed with Grammatik (Fry, 1977), the literacy of the participants with the Rapid Estimate of Adult Literacy (REALM) in Medicine test, and the suitability of the brochure was tested with the Suitability Assessment of Materials measure (Doak, Doak, & Root, 1993). The average REALM score for participation in this study correlated with a reading level of 7th-8th grade. All six brochures were found to be too difficult for many patients. Readability levels in four of the brochures were at 11th- or 12th-grade levels, one at 9th grade, and one at 10th grade. Materials with readability levels for 9th grade or higher should be rewritten to be understandable by most Americans, or supplemental instruction should be given. Readability and suitability assessments should be made to determine whether educational materials are appropriate for patients.

  14. Creating a Gold Standard for the Readability Measurement of Health Texts

    PubMed Central

    Kandula, Sasikiran; Zeng-Treitler, Qing

    2008-01-01

    Developing easy-to-read health texts for consumers continues to be a challenge in health communication. Though readability formulae such as Flesch-Kincaid Grade Level have been used in many studies, they were found to be inadequate to estimate the difficulty of some types of health texts. One impediment to the development of new readability assessment techniques is the absence of a gold standard that can be used to validate them. To overcome this deficiency, we have compiled a corpus of 324 health documents consisting of six different types of texts. These documents were manually reviewed and assigned a readability level (1-7 Likert scale) by a panel of five health literacy experts. The expert assigned ratings were found to be highly correlated with a patient representative’s readability ratings (r = 0.81, p<0.0001). PMID:18999150

  15. Structure and content of chronic kidney disease information on the World Wide Web: barriers to public understanding of a pandemic.

    PubMed

    Calderón, José Luis; Zadshir, Ashraf; Norris, Keith

    2004-10-01

    Chronic kidney disease (CKD) is a pandemic and the need to inform those at risk has never been more important. The World Wide Web (WWW) is no w considered a key source of health information, but the quality and utility of this information has been challenged. In this article, we assess structural, content, and linguistic barriers to accessed CKD information and discuss the implications of limited Internet access to communicating health. Technical (number of hyperlinks), content (number of six core CKD and risk factor information domains included), and linguistic (readability and variation in readability) barriers were assessed for websites offered by 12 kidney disease associations. The Flesch Reading Ease Index method was used to estimate readability scores, and variation in the readability of information was assessed. Eleven websites met inclusion criteria. Six of 11 websites provided information in all 6 domains of CKD information. A mean of 4 hyperlinks (range 3-5) was clicked before CKD information was available and a mean of 6 hyperlinks (range 4-12) was clicked to access all available CKD information. Mean readability scores for all six domains of CKD information exceeded national average literacy skills and far exceeded the 5th grade level readability desired for informing vulnerable populations. Information about CKD and diabetes consistently had higher readability scores. The WWW currently has little utility for informing populations at greatest risk for CKD. Barriers to accessing CKD information on the WWW are socioeconomic, technical, and linguistic. Having lower socioeconomic status, less access to computers and the WWW, multiple website hyperlinks, incomplete information, difficult readability, and significant variation in readability of CKD information on the WWW are social, structural, and content barriers to communicating CKD information. This may contribute to the growing epidemics of diminished public understanding about CKD, and disparities in CKD health status experienced by racial/ethnic minority populations globally.

  16. Evaluating the Readibility of Informed Consent Forms Available Before Anaesthesia: A Comparative Study

    PubMed Central

    Boztaş, Nilay; Özbilgin, Şule; Öçmen, Elvan; Altuntaş, Gözde; Özkardeşler, Sevda; Hancı, Volkan; Günerli, Ali

    2014-01-01

    Objective Informed consent forms that are used prior to administering anaesthesia inform patients before any proposed surgical procedure or treatment. They should provide patients with sufficient information about the operation and treatment. Readibility refers to whether it is easy or hard for a reader to read and understand an available text, and this is evaluated via various formulas. The aim of this study was to evaluate the readability of different informed consent forms commonly used in the anaesthesiology departments of different hospitals in our country using different readability formulas. Methods After obtaining ethics committee approval, the readability of different consent forms used in the anaesthesiology departments of university hospitals (n=15), Ministry of Health (MOH) education and research hospitals (n=15), and public hospitals (n=15) was analysed. Each consent form was displayed electronically in “Microsoft Word” and the number of words contained was counted automatically. The first 100 words on the first page of the forms were evaluated using the Gunning Fog, Flesch-Kincaid and Ateşman readability formulations. The rate of medical terms detected within these 100 words was determined as a percentage (%). Results Different consent forms obtained from 45 anaesthesia departments were assessed using various readability formulas. According to the Gunning Fog index, the readability of the consent forms obtained from MOH education and research and public hospitals was relatively low. The Flesch-Kincaid index measured very low levels of readability in all institutions. The Ateşman index displayed very low readability levels for the consent forms used in university hospitals, and low levels in other institutions. Conclusion We conclude that the readability of the anaesthesia informed consent forms is low. The level of education in our country should be considered in the preparation of anaesthesia consent forms. We believe that physicians should pay more attention to this medical and legal issue. PMID:27366408

  17. Readability of Spine-Related Patient Education Materials From Leading Orthopedic Academic Centers.

    PubMed

    Ryu, Justine H; Yi, Paul H

    2016-05-01

    Cross-sectional analysis of online spine-related patient education materials from leading academic centers. To assess the readability levels of spine surgery-related patient education materials available on the websites of academic orthopedic surgery departments. The Internet is becoming an increasingly popular resource for patient education. Yet many previous studies have found that Internet-based orthopedic-related patient education materials from subspecialty societies are written at a level too difficult for the average American; however, no prior study has assessed the readability of spine surgery-related patient educational materials from leading academic centers. All spine surgery-related articles from the online patient education libraries of the top five US News & World Report-ranked orthopedic institutions were assessed for readability using the Flesch-Kincaid (FK) readability test. Mean readability levels of articles amongst the five academic institutions and articles were compared. We also determined the number of articles with readability levels at or below the recommended sixth- or eight-grade levels. Intraobserver and interobserver reliability of readability assessment were assessed. A total of 122 articles were reviewed. The mean overall FK grade level was 11.4; the difference in mean FK grade level between each department varied significantly (range, 9.3-13.4; P < 0.0001). Twenty-three articles (18.9%) had a readability level at or below the eighth grade level, and only one (0.8%) was at or below the sixth grade level. Intraobserver and interobserver reliability were both excellent (intraclass correlation coefficient of 1 for both). Online patient education materials related to spine from academic orthopedic centers are written at a level too high for the average patient, consistent with spine surgery-related patient education materials provided by the American Academy of Orthopaedic Surgeons and spine subspecialty societies. This study highlights the potential difficulties patients might have in reading and comprehending the information in publicly available education materials related to spine. N/A.

  18. Readability Comparison of Pro- and Anti-Cancer Screening Online Messages in Japan

    PubMed Central

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2016-01-01

    Background: Cancer screening rates are lower in Japan than those in western countries. Health professionals publish pro-cancer screening messages on the internet to encourage audiences to undergo cancer screening. However, the information provided is often difficult to read for lay persons. Further, anti-cancer screening activists warn against cancer screening with messages on the Internet. We aimed to assess and compare the readability of pro- and anti-cancer screening online messages in Japan using a measure of readability. Methods: We conducted web searches at the beginning of September 2016 using two major Japanese search engines (Google.jp and Yahoo!.jp). The included websites were classified as “anti”, “pro”, or “neutral” depending on the claims, and “health professional” or “non-health professional” depending on the writers. Readability was determined using a validated measure of Japanese readability. Statistical analysis was conducted using two-way ANOVA. Results: In the total 159 websites analyzed, anti-cancer screening online messages were generally easier to read than pro-cancer screening online messages, Messages written by health professionals were more difficult to read than those written by non-health professionals. Claim × writer interaction was not significant. Conclusion: When health professionals prepare pro-cancer screening materials for publication online, we recommend they check for readability using readability assessment tools and improve text for easy comprehension when necessary. PMID:28125867

  19. Readability assessment of patient education materials from the American Academy of Otolaryngology--Head and Neck Surgery Foundation.

    PubMed

    Kasabwala, Khushabu; Agarwal, Nitin; Hansberry, David R; Baredes, Soly; Eloy, Jean Anderson

    2012-09-01

    Americans are increasingly turning to the Internet as a source of health care information. These online resources should be written at a level readily understood by the average American. This study evaluates the readability of online patient education information available from the American Academy of Otolaryngology--Head and Neck Surgery Foundation (AAO-HNSF) professional Web site using 7 different assessment tools that analyze the materials for reading ease and grade level of its target audience. Analysis of Internet-based patient education material from the AAO-HNSF Web site. Online patient education material from the AAO-HNSF was downloaded in January 2012 and assessed for level of readability using the Flesch Reading Ease, Flesch-Kincaid Grade Level, SMOG grading, Coleman-Liau Index, Gunning-Fog Index, Raygor Readability Estimate graph, and Fry Readability graph. The text from each subsection was pasted as plain text into Microsoft Word document, and each subsection was subjected to readability analysis using the software package Readability Studio Professional Edition Version 2012.1. All health care education material assessed is written between an 11th grade and graduate reading level and is considered "difficult to read" by the assessment scales. Online patient education materials on the AAO-HNSF Web site are written above the recommended 6th grade level and may need to be revised to make them more easily understood by a broader audience.

  20. Readability analysis of healthcare-oriented education resources from the American Academy of Facial Plastic and Reconstructive Surgery.

    PubMed

    Misra, Poonam; Agarwal, Nitin; Kasabwala, Khushabu; Hansberry, David R; Setzen, Michael; Eloy, Jean Anderson

    2013-01-01

    Deficient health literacy remains a widespread public issue. As such, the National Institutes of Health (NIH) recommends that all patient resources should be written around a sixth-grade level. The authors evaluate healthcare-oriented resources specified for patient use on the American Academy of Facial Plastic and Reconstructive Surgery (AAFPRS) Web site in order to identify potential areas of improvement and highlight those sections that may serve as paradigms for future revisions. Descriptive and correlational design. Seventeen healthcare-oriented resources specifically for patients were downloaded in February 2012 from the American Academy of Facial Plastic and Reconstructive Surgery Web site. Readability assessments of each article were performed using Readability Studio Professional Edition Version 2012.1. These tests included the Flesch Reading Ease, Flesch-Kincaid Grade Level, SMOG Grading, Coleman-Liau Index, Gunning-Fog Index, the New Fog Count, the New Dale-Chall Readability Formula, FORCAST formula, Raygor Readability Estimate, and the Fry Graph. Patient health education material found on the AAFPRS Web site has been found to be written at an average grade level of 12th grade using 10 different readability scales. Modifications of the patient education section of the AAFPRS Web site can increase the readability of the literature, and allow greater comprehension among a wider audience. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  1. Readability of American online patient education materials in urologic oncology: a need for simple communication.

    PubMed

    Pruthi, Amanda; Nielsen, Matthew E; Raynor, Mathew C; Woods, Michael E; Wallen, Eric M; Smith, Angela B

    2015-02-01

    To determine the readability levels of reputable cancer and urologic Web sites addressing bladder, prostate, kidney, and testicular cancers. Online patient education materials (PEMs) for bladder, prostate, kidney, and testicular malignancies were evaluated from the American Cancer Society, American Society of Clinical Oncology, National Cancer Institute, Urology Care Foundation, Bladder Cancer Advocacy Network, Prostate Cancer Foundation, Kidney Cancer Association, and Testicular Cancer Resource Center. Grade level was determined using several readability indices, and analyses were performed on the basis of cancer type, Web site, and content area (general, causes, risk factors and prevention, diagnosis and staging, treatment, and post-treatment). Estimated grade level of online PEMs ranged from 9.2 to 14.2 with an overall mean of 11.7. Web sites for kidney cancer had the least difficult readability (11.3) and prostate cancer had the most difficult readability (12.1). Among specific Web sites, the most difficult readability levels were noted for the Urology Care Foundation Web site for bladder and prostate cancer and the Kidney Cancer Association and Testicular Cancer Resource Center for kidney and testes cancer. Readability levels within content areas varied on the basis of the disease and Web site. Online PEMs in urologic oncology are written at a level above the average American reader. Simplification of these resources is necessary to improve patient understanding of urologic malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Systems, methods and computer-readable media to model kinetic performance of rechargeable electrochemical devices

    DOEpatents

    Gering, Kevin L.

    2013-01-01

    A system includes an electrochemical cell, monitoring hardware, and a computing system. The monitoring hardware samples performance characteristics of the electrochemical cell. The computing system determines cell information from the performance characteristics. The computing system also analyzes the cell information of the electrochemical cell with a Butler-Volmer (BV) expression modified to determine exchange current density of the electrochemical cell by including kinetic performance information related to pulse-time dependence, electrode surface availability, or a combination thereof. A set of sigmoid-based expressions may be included with the modified-BV expression to determine kinetic performance as a function of pulse time. The determined exchange current density may be used with the modified-BV expression, with or without the sigmoid expressions, to analyze other characteristics of the electrochemical cell. Model parameters can be defined in terms of cell aging, making the overall kinetics model amenable to predictive estimates of cell kinetic performance along the aging timeline.

  3. Use of a New Set of Linguistic Features to Improve Automatic Assessment of Text Readability

    ERIC Educational Resources Information Center

    Yoshimi, Takehiko; Kotani, Katsunori; Isahara, Hitoshi

    2012-01-01

    The present paper proposes and evaluates a readability assessment method designed for Japanese learners of EFL (English as a foreign language). The proposed readability assessment method is constructed by a regression algorithm using a new set of linguistic features that were employed separately in previous studies. The results showed that the…

  4. Matching Readers to Instructional Materials: The Use of Classic Readability Measures for Students with Language Learning Disabilities and Dyslexia.

    ERIC Educational Resources Information Center

    Kotula, Andrea Winokur

    2003-01-01

    The matching of students with language learning disabilities and dyslexia to appropriate reading materials is discussed, and formal and informal methods are presented for determining reading levels for accuracy, fluency, and comprehension instruction and practice. The Spache Readability Formula, the New Dale-Challe Readability Formula, and…

  5. Reply to "Further Issues in Determining the Readability of Self-Report Items: Comment on McHugh and Behar (2009)"

    ERIC Educational Resources Information Center

    McHugh, R. Kathryn; Behar, Evelyn

    2012-01-01

    In his commentary on our previously published article "Readability of Self-Report Measures of Depression and Anxiety," J. Schinka (2012) argued for the importance of considering readability of patient materials and highlighted limitations of existing methodologies for this assessment. Schinka's commentary articulately described the weaknesses of…

  6. Readability--The Situation Today. Reading Education Report No. 70.

    ERIC Educational Resources Information Center

    Davison, Alice

    Defining readability in both the narrow sense of formula use and refinement and the broader sense of the processing and comprehension of language, this paper argues for the need for more research focusing on readability as a way of improving the match between reader and text. Following a brief introduction, the paper reviews current readability…

  7. Readability of Wikipedia Pages on Autoimmune Disorders: Systematic Quantitative Assessment

    PubMed Central

    Bragazzi, Nicola Luigi; Brigo, Francesco; Sharif, Kassem; Amital, Howard; McGonagle, Dennis; Shoenfeld, Yehuda; Adawi, Mohammad

    2017-01-01

    Background In the era of new information and communication technologies, the Internet is being increasingly accessed for health-related information. Indeed, recently published patient surveys of people with autoimmune disorders confirmed that the Internet was reported as one of the most important health information sources. Wikipedia, a free online encyclopedia launched in 2001, is generally one of the most visited websites worldwide and is often consulted for health-related information. Objective The main objective of this investigation was to quantitatively assess whether the Wikipedia pages related to autoimmune disorders can be easily accessed by patients and their families, in terms of readability. Methods We obtained and downloaded a list of autoimmune disorders from the American Autoimmune Related Diseases Association (AARDA) website. We analyzed Wikipedia articles for their overall level of readability with 6 different quantitative readability scales: (1) the Flesch Reading Ease, (2) the Gunning Fog Index, (3) the Coleman-Liau Index, (4) the Flesch-Kincaid Grade Level, (5) the Automated Readability Index (ARI), and (6) the Simple Measure of Gobbledygook (SMOG). Further, we investigated the correlation between readability and clinical, pathological, and epidemiological parameters. Moreover, each Wikipedia analysis was assessed according to its content, breaking down the readability indices by main topic of each part (namely, pathogenesis, treatment, diagnosis, and prognosis plus a section containing paragraphs not falling into any of the previous categories). Results We retrieved 134 diseases from the AARDA website. The Flesch Reading Ease yielded a mean score of 24.34 (SD 10.73), indicating that the sites were very difficult to read and best understood by university graduates, while mean Gunning Fog Index and ARI scores were 16.87 (SD 2.03) and 14.06 (SD 2.12), respectively. The Coleman-Liau Index and the Flesch-Kincaid Grade Level yielded mean scores of 14.48 (SD 1.57) and 14.86 (1.95), respectively, while the mean SMOG score was 15.38 (SD 1.37). All the readability indices confirmed that the sites were suitable for a university graduate reading level. We found no correlation between readability and clinical, pathological, and epidemiological parameters. Differences among the different sections of the Wikipedia pages were statistically significant. Conclusions Wikipedia pages related to autoimmune disorders are characterized by a low level of readability. The onus is, therefore, on physicians and health authorities to improve the health literacy skills of patients and their families and to create, together with patients themselves, disease-specific readable sites, disseminating highly accessible health-related online information, in terms of both clarity and conciseness. PMID:28720555

  8. Readability of medicinal package leaflets: a systematic review

    PubMed Central

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords “Readability and Package Leaflet” and “Readability and Package Insert” in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results. PMID:25741660

  9. Assessing the Readability of Medical Documents: A Ranking Approach.

    PubMed

    Zheng, Jiaping; Yu, Hong

    2018-03-23

    The use of electronic health record (EHR) systems with patient engagement capabilities, including viewing, downloading, and transmitting health information, has recently grown tremendously. However, using these resources to engage patients in managing their own health remains challenging due to the complex and technical nature of the EHR narratives. Our objective was to develop a machine learning-based system to assess readability levels of complex documents such as EHR notes. We collected difficulty ratings of EHR notes and Wikipedia articles using crowdsourcing from 90 readers. We built a supervised model to assess readability based on relative orders of text difficulty using both surface text features and word embeddings. We evaluated system performance using the Kendall coefficient of concordance against human ratings. Our system achieved significantly higher concordance (.734) with human annotators than did a baseline using the Flesch-Kincaid Grade Level, a widely adopted readability formula (.531). The improvement was also consistent across different disease topics. This method's concordance with an individual human user's ratings was also higher than the concordance between different human annotators (.658). We explored methods to automatically assess the readability levels of clinical narratives. Our ranking-based system using simple textual features and easy-to-learn word embeddings outperformed a widely used readability formula. Our ranking-based method can predict relative difficulties of medical documents. It is not constrained to a predefined set of readability levels, a common design in many machine learning-based systems. Furthermore, the feature set does not rely on complex processing of the documents. One potential application of our readability ranking is personalization, allowing patients to better accommodate their own background knowledge. ©Jiaping Zheng, Hong Yu. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 23.03.2018.

  10. Further issues in determining the readability of self-report items: comment on McHugh and Behar (2009).

    PubMed

    Schinka, John A

    2012-10-01

    Issues regarding the readability of self-report assessment instruments, methods for establishing the reading ability level of respondents, and guidelines for development of scales designed for marginal readers have been inconsistently addressed in the literature. A recent study by McHugh and Behar (2009) provided new findings relevant to these issues. McHugh and Behar calculated indices of readability separately for the instructions and the item sets of 105 self-report measures of anxiety and depression. Results revealed substantial variability in readability among the measures, with most measures being written at or above the mean reading grade level in the United States. These results were consistent with those reported previously by Schinka and Borum (1993, 1994) in analyses of the readability of commonly used self-report psychopathology and personality inventories. In their discussion, McHugh and Behar addressed implications of their findings for clinical assessment and for scale development. I expand on their comments by addressing the failure to consider vocabulary difficulty, a major shortcoming of readability indices that examine only text complexity. I demonstrate how vocabulary difficulty influences readability and discuss additional considerations and possible solutions for addressing the gap between scale readability and the reading skill level of the self-report respondent. The work of McHugh and Behar clearly demonstrates that the issues of reading ability that arise in collecting self-report data are neither simple nor straightforward. Comments are offered to focus attention on the problems identified by their work. These problems will require additional effort on the part of researchers and clinicians in order to obtain reliable, valid estimates of clinical status. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  11. Readability of medicinal package leaflets: a systematic review.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  12. Security printing of covert quick response codes using upconverting nanoparticle inks

    NASA Astrophysics Data System (ADS)

    Meruga, Jeevan M.; Cross, William M.; May, P. Stanley; Luu, QuocAnh; Crawford, Grant A.; Kellar, Jon J.

    2012-10-01

    Counterfeiting costs governments and private industries billions of dollars annually due to loss of value in currency and other printed items. This research involves using lanthanide doped β-NaYF4 nanoparticles for security printing applications. Inks comprised of Yb3+/Er3+ and Yb3+/Tm3+ doped β-NaYF4 nanoparticles with oleic acid as the capping agent in toluene and methyl benzoate with poly(methyl methacrylate) (PMMA) as the binding agent were used to print quick response (QR) codes. The QR codes were made using an AutoCAD file and printed with Optomec direct-write aerosol jetting®. The printed QR codes are invisible under ambient lighting conditions, but are readable using a near-IR laser, and were successfully scanned using a smart phone. This research demonstrates that QR codes, which have been used primarily for information sharing applications, can also be used for security purposes. Higher levels of security were achieved by printing both green and blue upconverting inks, based on combinations of Er3+/Yb3+ and Tm3+/Yb3+, respectively, in a single QR code. The near-infrared (NIR)-to-visible upconversion luminescence properties of the two-ink QR codes were analyzed, including the influence of NIR excitation power density on perceived color, in term of the CIE 1931 chromaticity index. It was also shown that this security ink can be optimized for line width, thickness and stability on different substrates.

  13. Security printing of covert quick response codes using upconverting nanoparticle inks.

    PubMed

    Meruga, Jeevan M; Cross, William M; Stanley May, P; Luu, QuocAnh; Crawford, Grant A; Kellar, Jon J

    2012-10-05

    Counterfeiting costs governments and private industries billions of dollars annually due to loss of value in currency and other printed items. This research involves using lanthanide doped β-NaYF(4) nanoparticles for security printing applications. Inks comprised of Yb(3+)/Er(3+) and Yb(3+)/Tm(3+) doped β-NaYF(4) nanoparticles with oleic acid as the capping agent in toluene and methyl benzoate with poly(methyl methacrylate) (PMMA) as the binding agent were used to print quick response (QR) codes. The QR codes were made using an AutoCAD file and printed with Optomec direct-write aerosol jetting(®). The printed QR codes are invisible under ambient lighting conditions, but are readable using a near-IR laser, and were successfully scanned using a smart phone. This research demonstrates that QR codes, which have been used primarily for information sharing applications, can also be used for security purposes. Higher levels of security were achieved by printing both green and blue upconverting inks, based on combinations of Er(3+)/Yb(3+) and Tm(3+)/Yb(3+), respectively, in a single QR code. The near-infrared (NIR)-to-visible upconversion luminescence properties of the two-ink QR codes were analyzed, including the influence of NIR excitation power density on perceived color, in term of the CIE 1931 chromaticity index. It was also shown that this security ink can be optimized for line width, thickness and stability on different substrates.

  14. Modification and benchmarking of MCNP for low-energy tungsten spectra.

    PubMed

    Mercier, J R; Kopp, D T; McDavid, W D; Dove, S B; Lancaster, J L; Tucker, D M

    2000-12-01

    The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with benchmark spectra was supplemented with independent electron-only and photon-only transport benchmarks. Major revisions to the code included the proper treatment of characteristic K x-ray production and scoring, new impact ionization cross sections, and new bremsstrahlung cross sections. Minor revisions included updated photon cross sections, electron-electron bremsstrahlung production, and K x-ray yield. The modified MCNP code is benchmarked to electron backscatter factors, x-ray spectra production, and primary and scatter photon transport.

  15. Validation of a modified table to map the 1998 Abbreviated Injury Scale to the 2008 scale and the use of adjusted severities.

    PubMed

    Tohira, Hideo; Jacobs, Ian; Mountain, David; Gibson, Nick; Yeo, Allen; Ueno, Masato; Watanabe, Hiroaki

    2011-12-01

    The Abbreviated Injury Scale 2008 (AIS 2008) is the most recent injury coding system. A mapping table from a previous AIS 98 to AIS 2008 is available. However, AIS 98 codes that are unmappable to AIS 2008 codes exist in this table. Furthermore, some AIS 98 codes can be mapped to multiple candidate AIS 2008 codes with different severities. We aimed to modify the original table to adjust the severities and to validate these changes. We modified the original table by adding links from unmappable AIS 98 codes to AIS 2008 codes. We applied the original table and our modified table to AIS 98 codes for major trauma patients. We also assigned candidate codes with different severities the weighted averages of their severities as an adjusted severity. The proportion of cases whose injury severity scores (ISSs) were computable were compared. We also compared the agreement of the ISS and New ISS (NISS) between manually determined AIS 2008 codes (MAN) and mapped codes by using our table (MAP) with unadjusted or adjusted severities. All and 72.3% of cases had their ISSs computed by our modified table and the original table, respectively. The agreement between MAN and MAP with respect to the ISS and NISS was substantial (intraclass correlation coefficient = 0.939 for ISS and 0.943 for NISS). Using adjusted severities, the agreements of the ISS and NISS improved to 0.953 (p = 0.11) and 0.963 (p = 0.007), respectively. Our modified mapping table seems to allow more ISSs to be computed than the original table. Severity scores exhibited substantial agreement between MAN and MAP. The use of adjusted severities improved these agreements further.

  16. An introduction to scripting in Ruby for biologists

    PubMed Central

    Aerts, Jan; Law, Andy

    2009-01-01

    The Ruby programming language has a lot to offer to any scientist with electronic data to process. Not only is the initial learning curve very shallow, but its reflection and meta-programming capabilities allow for the rapid creation of relatively complex applications while still keeping the code short and readable. This paper provides a gentle introduction to this scripting language for researchers without formal informatics training such as many wet-lab scientists. We hope this will provide such researchers an idea of how powerful a tool Ruby can be for their data management tasks and encourage them to learn more about it. PMID:19607723

  17. A Software Application for Assessing Readability in the Japanese EFL Context

    ERIC Educational Resources Information Center

    Ozasa, Toshiaki; Weir, George R. S.; Fukui, Masayasu

    2010-01-01

    We have been engaged in developing a readability index and its application software attuned for Japanese EFL learners. The index program, Ozasa-Fukui Year Level Program, Ver. 1.0, was used in developing the readability metric Ozasa-Fukui Year Level Index but tended to assume a high level of computer knowledge in its users. As a result, the…

  18. Does Machine-Readable Documentation on Online Hosts and CD-ROMs Have a Role or Future?

    ERIC Educational Resources Information Center

    Harris, Stephen; Oppenheim, Charles

    1996-01-01

    Reports results of a United Kingdom-based mail survey of database users, CD-ROM producers, and hosts to assess trends and views concerning documentation in machine-readable form. Cost, convenience, and ease of use of print manuals are cited as reasons for the reluctance to switch to machine-readable documentation. Sample surveys are included.…

  19. Simulation-Based Rule Generation Considering Readability

    PubMed Central

    Yahagi, H.; Shimizu, S.; Ogata, T.; Hara, T.; Ota, J.

    2015-01-01

    Rule generation method is proposed for an aircraft control problem in an airport. Designing appropriate rules for motion coordination of taxiing aircraft in the airport is important, which is conducted by ground control. However, previous studies did not consider readability of rules, which is important because it should be operated and maintained by humans. Therefore, in this study, using the indicator of readability, we propose a method of rule generation based on parallel algorithm discovery and orchestration (PADO). By applying our proposed method to the aircraft control problem, the proposed algorithm can generate more readable and more robust rules and is found to be superior to previous methods. PMID:27347501

  20. Readability of patient education materials in ophthalmology: a single-institution study and systematic review.

    PubMed

    Williams, Andrew M; Muir, Kelly W; Rosdahl, Jullia A

    2016-08-03

    Patient education materials should be written at a level that is understandable for patients with low health literacy. The aims of this study are (1) to review the literature on readability of ophthalmic patient education materials and (2) to evaluate and revise our institution's patient education materials about glaucoma using evidence-based guidelines on writing for patients with low health literacy. A systematic search was conducted on the PubMed/MEDLINE database for studies that have evaluated readability level of ophthalmic patient education materials, and the reported readability scores were assessed. Additionally, we collected evidence-based guidelines for writing easy-to-read patient education materials, and these recommendations were applied to revise 12 patient education handouts on various glaucoma topics at our institution. Readability measures, including Flesch-Kincaid Grade Level (FKGL), and word count were calculated for the original and revised documents. The original and revised versions of the handouts were then scored in random order by two glaucoma specialists using the Suitability Assessment of Materials (SAM) instrument, a grading scale used to evaluate suitability of health information materials for patients. Paired t test was used to analyze changes in readability measures, word count, and SAM score between original and revised handouts. Finally, five glaucoma patients were interviewed to discuss the revised materials, and patient feedback was analyzed qualitatively. Our literature search included 13 studies that evaluated a total of 950 educational materials. Among the mean FKGL readability scores reported in these studies, the median was 11 (representing an eleventh-grade reading level). At our institution, handouts' readability averaged a tenth-grade reading level (FKGL = 10.0 ± 1.6), but revising the handouts improved their readability to a sixth-grade reading level (FKGL = 6.4 ± 1.2) (p < 0.001). Additionally, the mean SAM score of our institution's handouts improved from 60 ± 7 % (adequate) for the original versions to 88 ± 4 % (superior) for the revised handouts (p < 0.001). Our systematic review of the literature reveals that ophthalmic patient education materials are consistently written at a level that is too high for many patients to understand. Our institution's experience suggests that applying guidelines on writing easy-to-understand material can improve the readability and suitability of educational materials for patients with low health literacy.

  1. [Readability and internet accessibility of informative documents for spinal cord injury patients in Spanish].

    PubMed

    Bea-Muñoz, M; Medina-Sánchez, M; Flórez-García, M T

    2015-01-01

    Patients with spinal cord injuries and their carers have access to leaflets on Internet that they can use as educational material to complement traditional forms of education. The aim of this study is to evaluate the readability of informative documents in Spanish, obtained from Internet and aimed at patients with spinal cord injuries. A search was made with the Google search engine using the following key words: recommendation, advice, guide, manual, self-care, education and information, adding spinal cord injury, paraplegia and tetraplegia to each of the terms. We analyzed the first 50 results of each search. The readability of the leaflets was studied with the Flesch-Szigriszt index and the INFLESZ scale, both available on the INFLESZ program. Also indicated were year of publication, country and number of authors of the documents obtained. We obtained 16 documents, developed between 2001 and 2011. Readability oscillated between 43.34 (some-what difficult) and 62 (normal), with an average value of 51.56 (somewhat difficult). Only 4 pamphlets (25%) showed a Flesch-Szigriszt index of ≥ 55 (normal). There was no difference in readability by year, authors or country of publication. The readability of 75% of the documents studied was "somewhat difficult" according to the INFLESZ scale. These results coincide with previous studies, in both Spanish and English. If the readability of this type of documents is improved, it will be easier to achieve their educational goal.

  2. Readability and suitability assessment of patient education materials in rheumatic diseases.

    PubMed

    Rhee, Rennie L; Von Feldt, Joan M; Schumacher, H Ralph; Merkel, Peter A

    2013-10-01

    Web-based patient education materials and printed pamphlets are frequently used by providers to inform patients about their rheumatic disease. Little attention has been given to the readability and appropriateness of patient materials. The objective of this study was to examine the readability and suitability of commonly used patient education materials for osteoarthritis (OA), rheumatoid arthritis, systemic lupus erythematosus, and vasculitis. Five or 6 popular patient resources for each disease were chosen for evaluation. Readability was measured using the Flesch-Kincaid reading grade level and suitability was determined by the Suitability Assessment of Materials (SAM), a score that considers characteristics such as content, graphics, layout/topography, and cultural appropriateness. Three different reviewers rated the SAM score and means were used in the analysis. Twenty-three resources written on the 4 diseases were evaluated. The education material for all 4 diseases studied had readability above the eighth-grade level and readability did not differ among the diseases. Only 5 of the 23 resources received superior suitability scores, and 3 of these 5 resources were written for OA. All 4 diseases received adequate suitability scores, with OA having the highest mean suitability score. Most patient education materials for rheumatic diseases are written at readability levels above the recommended sixth-grade reading level and have only adequate suitability. Developing more appropriate educational resources for patients with rheumatic diseases may improve patient comprehension. Copyright © 2013 by the American College of Rheumatology.

  3. Oil and gas field code master list 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This is the thirteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1994 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. The master field name spellings and codes are to be used by respondents when filing the following Department of Energy (DOE) forms: Form EIA-23, {open_quotes}Annual Survey of Domestic Oil and Gas Reserves,{close_quotes} filed by oil and gas well operators (field codes are required from larger operators only); Forms FERC 8 and EIA-191, {open_quotes}Underground Gas Storagemore » Report,{close_quotes} filed by natural gas producers and distributors who operate underground natural gas storage facilities. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161, (703) 487-4650. In order for the Master List to be useful, it must be accurate and remain current. To accomplish this, EIA constantly reviews and revises this list. The EIA welcomes all comments, corrections, and additions to the Master List. All such information should be given to the EIA Field Code Coordinator at (214) 953-1858. EIA gratefully acknowledges the assistance provides by numerous State organizations and trade associations in verifying the existence of fields and their official nomenclature.« less

  4. Readability and the Production of Instructional Text in the Royal Navy,

    DTIC Science & Technology

    1980-11-01

    Conclusions 28 References 35 Appendix A Royal Naval Educational and Training Establishrents Surveyed during the Project. Appendix B Readability and the...systematic assessment has been recognised for sone time. Educators understandably showed an interest in readability. Klare [351 reported cases of...covered, the purposes of the study were explained and discussed. 2. Subjects: Contact was made with all the major educational and training establishments

  5. Department of Defense Logistics Roadmap 2008. Volume 1

    DTIC Science & Technology

    2008-07-01

    machine readable identification mark on the Department’s tangible qualifying assets, and establishes the data management protocols needed to...uniquely identify items with a Unique Item Identifier (UII) via machine - readable information (MRI) marking represented by a two-dimensional data...property items with a machine -readable Unique Item Identifier (UII), which is a set of globally unique data elements. The UII is used in functional

  6. Readability Levels of the Reading Passages in the ITED: Final Report. Iowa Testing Programs Research Report. Number 6.

    ERIC Educational Resources Information Center

    Forsyth, Robert

    The readability level of passages from three subtests of the Iowa Tests of Educational Development (ITED), Forms X-6 and Y-6, were compared with the readability level of passages selected from the Des Moines Resister, Reader's Digest, Time, Newsweek, Saturday Review, and 18 high school textbooks from the fields of social studies, science, and…

  7. Readability of Wikipedia Pages on Autoimmune Disorders: Systematic Quantitative Assessment.

    PubMed

    Watad, Abdulla; Bragazzi, Nicola Luigi; Brigo, Francesco; Sharif, Kassem; Amital, Howard; McGonagle, Dennis; Shoenfeld, Yehuda; Adawi, Mohammad

    2017-07-18

    In the era of new information and communication technologies, the Internet is being increasingly accessed for health-related information. Indeed, recently published patient surveys of people with autoimmune disorders confirmed that the Internet was reported as one of the most important health information sources. Wikipedia, a free online encyclopedia launched in 2001, is generally one of the most visited websites worldwide and is often consulted for health-related information. The main objective of this investigation was to quantitatively assess whether the Wikipedia pages related to autoimmune disorders can be easily accessed by patients and their families, in terms of readability. We obtained and downloaded a list of autoimmune disorders from the American Autoimmune Related Diseases Association (AARDA) website. We analyzed Wikipedia articles for their overall level of readability with 6 different quantitative readability scales: (1) the Flesch Reading Ease, (2) the Gunning Fog Index, (3) the Coleman-Liau Index, (4) the Flesch-Kincaid Grade Level, (5) the Automated Readability Index (ARI), and (6) the Simple Measure of Gobbledygook (SMOG). Further, we investigated the correlation between readability and clinical, pathological, and epidemiological parameters. Moreover, each Wikipedia analysis was assessed according to its content, breaking down the readability indices by main topic of each part (namely, pathogenesis, treatment, diagnosis, and prognosis plus a section containing paragraphs not falling into any of the previous categories). We retrieved 134 diseases from the AARDA website. The Flesch Reading Ease yielded a mean score of 24.34 (SD 10.73), indicating that the sites were very difficult to read and best understood by university graduates, while mean Gunning Fog Index and ARI scores were 16.87 (SD 2.03) and 14.06 (SD 2.12), respectively. The Coleman-Liau Index and the Flesch-Kincaid Grade Level yielded mean scores of 14.48 (SD 1.57) and 14.86 (1.95), respectively, while the mean SMOG score was 15.38 (SD 1.37). All the readability indices confirmed that the sites were suitable for a university graduate reading level. We found no correlation between readability and clinical, pathological, and epidemiological parameters. Differences among the different sections of the Wikipedia pages were statistically significant. Wikipedia pages related to autoimmune disorders are characterized by a low level of readability. The onus is, therefore, on physicians and health authorities to improve the health literacy skills of patients and their families and to create, together with patients themselves, disease-specific readable sites, disseminating highly accessible health-related online information, in terms of both clarity and conciseness. ©Abdulla Watad, Nicola Luigi Bragazzi, Francesco Brigo, Kassem Sharif, Howard Amital, Dennis McGonagle, Yehuda Shoenfeld, Mohammad Adawi. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 18.07.2017.

  8. Pseudo-orthogonal frequency coded wireless SAW RFID temperature sensor tags.

    PubMed

    Saldanha, Nancy; Malocha, Donald C

    2012-08-01

    SAW sensors are ideal for various wireless, passive multi-sensor applications because they are small, rugged, radiation hard, and offer a wide range of material choices for operation over broad temperature ranges. The readable distance of a tag in a multi-sensor environment is dependent on the insertion loss of the device and the processing gain of the system. Single-frequency code division multiple access (CDMA) tags that are used in high-volume commercial applications must have universal coding schemes and large numbers of codes. The use of a large number of bits at the common center frequency to achieve sufficient code diversity in CDMA tags necessitates reflector banks with >30 dB loss. Orthogonal frequency coding is a spread-spectrum approach that employs frequency and time diversity to achieve enhanced tag properties. The use of orthogonal frequency coded (OFC) SAW tags reduces adjacent reflector interactions for low insertion loss, increased range, complex coding, and system processing gain. This work describes a SAW tag-sensor platform that reduces device loss by implementing long reflector banks with optimized spectral coding. This new pseudo-OFC (POFC) coding is defined and contrasted with the previously defined OFC coding scheme. Auto- and cross-correlation properties of the chips and their relation to reflectivity per strip and reflector length are discussed. Results at 250 MHz of 8-chip OFC and POFC SAW tags will be compared. The key parameters of insertion loss, cross-correlation, and autocorrelation of the two types of frequency-coded tags will be analyzed, contrasted, and discussed. It is shown that coded reflector banks can be achieved with near-zero loss and still maintain good coding properties. Experimental results and results predicted by the coupling of modes model are presented for varying reflector designs and codes. A prototype 915-MHz POFC sensor tag is used as a wireless temperature sensor and the results are shown.

  9. Readability of Internet Information on Hearing: Systematic Literature Review.

    PubMed

    Laplante-Lévesque, Ariane; Thorén, Elisabet Sundewall

    2015-09-01

    This systematic literature review asks the following question: “ What is the readability of Internet information on hearing that people with hearing impairment and their significant others can access in the context of their hearing care?” Searches were completed in three databases: CINAHL, PubMed, and Scopus. Seventy-eight records were identified and systematically screened for eligibility: 8 records were included that contained data on the readability of Internet information on hearing that people with hear ing impairment and their significant others can access in the context of their hearing care. Records reported mean readability levels from 9 to over 14. In other words, people with hearing impairment and their significant others need 9 to 14 years of education to read and understand Internet information on hearing that they access in the context of their hearing care. The poor readability of Internet information on hearing has been well documented; it is time to focus on valid and sustainable initiatives that address this problem.

  10. How Effective Are Patient Education Materials in Educating Patients?

    PubMed

    Keçeci, Ayla; Toprak, Sadiye; Kiliç, Seçil

    2017-11-01

    The aim of this research was to evaluate the patient education materials prepared and published by nurses and physicians in terms of the qualitative properties of these materials, including readability, understandability, and actionability. A total of 38 patient education materials prepared by nurses and physicians in a university hospital in Turkey were evaluated. The readability of the materials was assessed using the formulas proposed by Atesman and Cetinkaya. The Patient Education Materials Assessment Tool (PEMAT) form was used for estimating the understandability and actionability. Data were analyzed using the percentile and mean values, and the Kendall's Tau-c and correlation tests were used for interobserver agreement. According to the assessments based on the readability formulas, 55.3% of the materials were moderately difficult, while 81.6% had instructional-level readability (U.S. Grades 8 and 9) with a moderate to low level of understandability and actionability. Consequently, the patient education materials evaluated in our study had a moderate level of readability, understandability, and actionability.

  11. Readability assessment of online patient education materials from academic otolaryngology-head and neck surgery departments.

    PubMed

    Svider, Peter F; Agarwal, Nitin; Choudhry, Osamah J; Hajart, Aaron F; Baredes, Soly; Liu, James K; Eloy, Jean Anderson

    2013-01-01

    The aim of this study was to compare the readability of online patient education materials among academic otolaryngology departments in the mid-Atlantic region, with the purpose of determining whether these commonly used online resources were written at a level readily understood by the average American. A readability analysis of online patient education materials was performed using several commonly used readability assessments including the Flesch Reading Ease Score, the Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning Frequency of Gobbledygook, the New Dale-Chall Test, the Coleman-Liau Index, the New Fog Count, the Raygor Readability Estimate, the FORCAST test, and the Fry Graph. Most patient education materials from these programs were written at or above an 11th grade reading level, considerably above National Institutes of Health guidelines for recommended difficulty. Patient educational materials from academic otolaryngology Web sites are written at too difficult a reading level for a significant portion of patients and can be simplified. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Documentation for the machine-readable version of the Morphological Catalogue of Galaxies (MCG) of Vorontsov-Velyaminov et al, 1962-1968

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1982-01-01

    Modifications, corrections, and the record format are provided for the machine-readable version of the "Morphological Catalogue of Galaxies.' In addition to hundreds of individual corrections, a detailed comparison of the machine-readable with the published catalogue resulted in the addition of 116 missing objects, the deletion of 10 duplicate records, and a format modification to increase storage efficiency.

  13. Survey of quality, readability, and social reach of websites on osteosarcoma in adolescents.

    PubMed

    Lam, Catherine G; Roter, Debra L; Cohen, Kenneth J

    2013-01-01

    Little is known about Internet resources for adolescent patients. This study assessed the quality, readability, and social reach of websites on an illustrative adolescent cancer diagnosis, osteosarcoma. The top 50 results from four queries in two search engines were screened. Quality and readability were determined using standard DISCERN tool, Flesch Reading Ease and Flesch-Kinkaid Grade. Social reach was gauged by social networking links, global website traffic, and a pilot adolescent-specificity measure. Of 400 websites assessed, 56 (14%) met inclusion criteria. Websites' mean quality was fair (49.8 on 75-point scale; range 31.0-66.0, poor to excellent); 86% failed readability standards (Grade>8); 75% offered at least one social networking link; and 34% offered site-specific social media. More than 60% received over 50,000 visits in the past month. Only 12.5% included adolescent-specific content. Of the 10 websites ranked highest for quality, only one achieved both readability targets and adolescent-specific content. Although some patient-oriented websites on osteosarcoma are of acceptable quality, most failed readability targets, and few appeared to address adolescents. Better awareness of Internet health resources and social media for adolescents with cancer is needed to address gaps, promote health literacy and facilitate patient-provider communication. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Evaluation of online consumer medication information.

    PubMed

    Kim, Karissa Y; Metzger, Anne; Wigle, Patricia R; Choe, Pearl J

    2011-06-01

    Millions of Americans search the Internet for health-related information; however, the readability and comprehensiveness of consumer medication information (CMI) on the Internet has not been widely studied. The purpose of this study was to evaluate the readability and comprehensiveness of online CMI. The readability and comprehensiveness of consumer drug information found on 3 well-known Web sites (Medline Plus, Yahoo Health, and WebMD) was evaluated; in particular, information related to 10 commonly prescribed medications. Readability was assessed using the Simple Measure of Gobbledygook (SMOG) and Fry Readability Graph (FRG) tools; comprehensiveness of information was evaluated using the Keystone action plan criteria. Using SMOG, the mean reading level of each Web site was 13th grade level or higher. Using the FRG, the mean reading level was 10th grade or higher. Out of the 24 points in the Keystone action plan criteria, information found on each of the Web sites was deemed accurate with mean score of 21, 21, and 19 for Medline Plus, Yahoo Health, and WebMD, respectively. For the medications reviewed, CMI found on Web sites was accurate when assessed using the Keystone action plan criteria. The readability levels were higher than the recommended sixth grade level. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Readability of sports medicine-related patient education materials from the American Academy of Orthopaedic Surgeons and the American Orthopaedic Society for Sports Medicine.

    PubMed

    Ganta, Abhishek; Yi, Paul H; Hussein, Khalil; Frank, Rachel M

    2014-04-01

    Although studies have revealed high readability levels of orthopedic patient education materials, no study has evaluated sports medicine-related patient education materials. We conducted a study to assess the readability of sports medicine-related patient education materials from the American Academy of Orthopaedic Surgeons (AAOS) and the American Orthopaedic Society for Sports Medicine (AOSSM). All sports medicine patient education articles available online in 2012 from the AAOS and the AOSSM, including the Stop Sports Injuries Campaign (STOP), were identified, and their readability was assessed with the Flesch-Kinkaid (FK) readability test. Mean overall FK grade level of the 170 articles reviewed (104 from AAOS, 36 from AOSSM, 30 from STOP) was 10.2. Mean FK levels for the 3 sources were 9.5 (AAOS), 11.0 (AOSSM), and 11.5 (STOP) (P = .16). Fifteen (8.8%) of the 170 articles had a readability level at or below eighth grade (average reading level of US adults); only 2 (1.2%) of the 170 articles were at or below the recommended sixth-grade level. The majority of sports medicine-related patient education materials from AAOS and AOSSM had reading levels higher than recommended, indicating that the majority of the patient population may find it difficult to comprehend these articles.

  16. Readability assessment of online patient education materials provided by the European Association of Urology.

    PubMed

    Betschart, Patrick; Zumstein, Valentin; Bentivoglio, Maico; Engeler, Daniel; Schmid, Hans-Peter; Abt, Dominik

    2017-12-01

    To assess the readability of the web-based patient education material provided by the European Association of Urology. English patient education materials (PEM) as available in May 2017 were obtained from the EAU website. Each topic was analyzed separately using six well-established readability assessment tools, including Flesch-Kincaid Grade Level (FKGL), SMOG Grade Level (SMOG), Coleman-Liau Index (CLI), Gunning Fog Index (GFI), Flesch Reading Ease Formula (FRE) and Fry Readability Graph (FRG). A total of 17 main topics were identified of which separate basic and in-depth information is provided for 14 topics. Calculation of grade levels (FKGL, SMOG, CLI, GFI) showed readability scores of 7th-13th grade for basic information, 8th-15th grade for in-depth information and 7th-15th grade for single PEM. Median FRE score was 54 points (range 45-65) for basic information and 56 points (41-64) for in-depth information. The FRG as a graphical assessment revealed only 13 valid results with an approximate 8th-17th grade level. The EAU provides carefully worked out PEM for 17 urological topics. Although improved readability compared to similar analyses was found, a simplification of certain chapters might be helpful to facilitate better patient understanding.

  17. Readability of Orthopedic Trauma Patient Education Materials on the Internet.

    PubMed

    Mohan, Rohith; Yi, Paul H; Morshed, Saam

    In this study, we used the Flesch-Kincaid Readability Scale to determine the readability levels of orthopedic trauma patient education materials on the American Academy of Orthopaedic Surgeons (AAOS) website and to examine how subspecialty coauthorship affects readability level. Included articles from the AAOS online patient education library and the AAOS OrthoPortal website were categorized as trauma or broken bones and injuries on the AAOS online library or were screened by study authors for relevance to orthopedic trauma. Subsequently, the Flesch-Kincaid scale was used to determine each article's readability level, which was reported as a grade level. Subspecialty coauthorship was noted for each article. A total of 115 articles from the AAOS website were included in the study and reviewed. Mean reading level was grade 9.1 for all articles reviewed. Nineteen articles (16.5%) were found to be at or below the eighth-grade level, and only 1 article was at or below the sixth-grade level. In addition, there was no statistically significant difference between articles coauthored by the various orthopedic subspecialties and those authored exclusively by AAOS. Orthopedic trauma readability materials on the AAOS website appear to be written at a reading comprehension level too high for the average patient to understand.

  18. Quality and readability assessment of websites related to recurrent respiratory papillomatosis.

    PubMed

    San Giorgi, Michel R M; de Groot, Olivier S D; Dikkers, Frederik G

    2017-10-01

    Recurrent respiratory papillomatosis (RRP) is a rare disease for which a limited number of information sources for patients exist. The role of the Internet in the patient-physician relationship is increasing. More and more patients search for online health information, which should be of good quality and easy readable. The study aim was to investigate the quality and readability of English online health information about RRP. Quality and readability assessment of online information. Relevant information was collected using three different search engines and seven different search terms. Quality was assessed with the DISCERN instrument. The Flesch Reading Ease Score (FRES) and average grade level (AGL) were determined to measure readability of the English websites. Fifty-one English websites were included. The mean DISCERN score of the websites is 28.1 ± 9.7 (poor quality); the mean FRES is 41.3 ± 14.9 (difficult to read); and the mean AGL is 12.6 ± 2.3. The quality and readability of English websites about RRP is alarmingly poor. NA. Laryngoscope, 127:2293-2297, 2017. © 2017 The Authors The Laryngoscope published by Wiley Periodicals, Inc. on behalf of American Laryngological, Rhinological and Otological Society Inc, “The Triological Society” and American Laryngological Association (ALA).

  19. Readability of Healthcare Literature for Gastroparesis and Evaluation of Medical Terminology in Reading Difficulty.

    PubMed

    Meillier, Andrew; Patel, Shyam

    2017-02-01

    Gastroparesis is a chronic condition that can be further enhanced with patient understanding. Patients' education resources on the Internet have become increasingly important in improving healthcare literacy. We evaluated the readability of online resources for gastroparesis and the influence by medical terminology. Google searches were performed for "gastroparesis", "gastroparesis patient education material" and "gastroparesis patient information". Following, all medical terminology was determined if included on Taber's Medical Dictionary 22nd Edition. The medical terminology was replaced independently with "help" and "helping". Web resources were analyzed with the Readability Studio Professional Edition (Oleander Solutions, Vandalia, OH) using 10 different readability scales. The average of the 26 patient education resources was 12.7 ± 1.8 grade levels. The edited "help" group had 6.6 ± 1.0 and "helping" group had 10.4 ± 2.1 reading levels. In comparing the three groups, the "help" and "helping" groups had significantly lower readability levels (P < 0.001). The "help" group was significantly less than the "helping" group (P < 0.001). The web resources for gastroparesis were higher than the recommended reading level by the American Medical Association. Medical terminology was shown to be the cause for this elevated readability level with all, but four resources within the recommended grade levels following word replacement.

  20. Assessment of readability, understandability, and completeness of pediatric hospital medicine discharge instructions.

    PubMed

    Unaka, Ndidi I; Statile, Angela; Haney, Julianne; Beck, Andrew F; Brady, Patrick W; Jerardi, Karen E

    2017-02-01

    The average American adult reads at an 8th-grade level. Discharge instructions written above this level might increase the risk of adverse outcomes for children as they transition from hospital to home. We conducted a cross-sectional study at a large urban academic children's hospital to describe readability levels, understandability scores, and completeness of written instructions given to families at hospital discharge. Two hundred charts for patients discharged from the hospital medicine service were randomly selected for review. Written discharge instructions were extracted and scored for readability (Fry Readability Scale [FRS]), understandability (Patient Education Materials Assessment Tool [PEMAT]), and completeness (5 criteria determined by consensus). Descriptive statistics enumerated the distribution of readability, understandability, and completeness of written discharge instructions. Of the patients included in the study, 51% were publicly insured. Median age was 3.1 years, and median length of stay was 2.0 days. The median readability score corresponded to a 10th-grade reading level (interquartile range, 8-12; range, 1-13). Median PEMAT score was 73% (interquartile range, 64%-82%; range, 45%-100%); 36% of instructions scored below 70%, correlating with suboptimal understandability. The diagnosis was described in only 33% of the instructions. Although explicit warning signs were listed in most instructions, 38% of the instructions did not include information on the person to contact if warning signs developed. Overall, the readability, understandability, and completeness of discharge instructions were subpar. Efforts to improve the content of discharge instructions may promote safe and effective transitions home. Journal of Hospital Medicine 2017;12:98-101. © 2017 Society of Hospital Medicine.

  1. Readability of Online Materials for Rhinoplasty.

    PubMed

    Santos, Pauline Joy F; Daar, David A; Paydar, Keyianoosh Z; Wirth, Garrett A

    2018-01-01

    Rhinoplasty is a popular aesthetic and reconstructive surgical procedure. However, little is known about the content and readability of online materials for patient education. The recommended grade level for educational materials is 7th to 8th grade according to the National Institutes of Health (NIH). This study aims to assess the readability of online patient resources for rhinoplasty. The largest public search engine, Google, was queried using the term "rhinoplasty" on February 26, 2016. Location filters were disabled and sponsored results excluded to avoid any inadvertent search bias. The 10 most popular websites were identified and all relevant, patient-directed information within one click from the original site was downloaded and saved as plain text. Readability was analyzed using five established analyses (Readability-score.com, Added Bytes, Ltd., Sussex, UK). Analysis of ten websites demonstrates an average grade level of at least 12 th grade. No material was at the recommended 7 th to 8 th grade reading level (Flesch-Kincaid, 11.1; Gunning-Fog, 14.1; Coleman-Liau, 14.5; SMOG 10.4; Automated Readability, 10.7; Average Grade Level, 12.2). Overall Flesch-Kincaid Reading Ease Index was 43.5, which is rated as "difficult." Online materials available for rhinoplasty exceed NIH-recommended reading levels, which may prevent appropriate decision-making in patients considering these types of surgery. Outcomes of this study identify that Plastic Surgeons should be cognizant of available online patient materials and make efforts to develop and provide more appropriate materials. Readability results can also contribute to marketing strategy and attracting a more widespread interest in the procedure.

  2. Web-based information on the treatment of oral leukoplakia - quality and readability.

    PubMed

    Wiriyakijja, Paswach; Fedele, Stefano; Porter, Stephen; Ni Riordain, Richeal

    2016-09-01

    To categorise the content and assess the quality and readability of the online information regarding the treatment for oral leukoplakia. An online search using the term 'leukoplakia treatment' was carried out on 8th June 2015 using the Google search engine. The content, quality and readability of the first 100 sites were explored. The quality of the web information was assessed using the following tools, the DISCERN instrument and the Journal of the American Medical Association (JAMA) benchmarks for website analysis and the HON seal. Readability was assessed via the Flesch Reading Ease Score. The search strategy generated 357 000 sites on the Google search engine. Due to duplicate links, non-operating links and irrelevant links, a total of 47 of the first 100 websites were included in this study. The mean overall rating achieved by included websites using the DISCERN instrument was 2.3. With regard to the JAMA benchmarks, the vast majority of examined websites (95.7%) completely fulfilled the disclosure benchmark and less than 50% of included websites met the three remaining criteria. A mean total readability score of 47.5 was recorded with almost 90% of websites having a readability level ranging from fairly difficult to very difficult. Based on this study, the online health information regarding oral leukoplakia has challenging readability with content of questionable accuracy. As patients often search for health information online, it would be prudent for clinicians to highlight the caution with which online information should be interpreted. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Readability of Online Materials for Rhinoplasty

    PubMed Central

    Santos, Pauline Joy F; Daar, David A; Paydar, Keyianoosh Z; Wirth, Garrett A

    2018-01-01

    BACKGROUND Rhinoplasty is a popular aesthetic and reconstructive surgical procedure. However, little is known about the content and readability of online materials for patient education. The recommended grade level for educational materials is 7th to 8th grade according to the National Institutes of Health (NIH). This study aims to assess the readability of online patient resources for rhinoplasty. METHODS The largest public search engine, Google, was queried using the term “rhinoplasty” on February 26, 2016. Location filters were disabled and sponsored results excluded to avoid any inadvertent search bias. The 10 most popular websites were identified and all relevant, patient-directed information within one click from the original site was downloaded and saved as plain text. Readability was analyzed using five established analyses (Readability-score.com, Added Bytes, Ltd., Sussex, UK). RESULTS Analysis of ten websites demonstrates an average grade level of at least 12th grade. No material was at the recommended 7th to 8th grade reading level (Flesch-Kincaid, 11.1; Gunning-Fog, 14.1; Coleman-Liau, 14.5; SMOG 10.4; Automated Readability, 10.7; Average Grade Level, 12.2). Overall Flesch-Kincaid Reading Ease Index was 43.5, which is rated as “difficult.” CONCLUSION Online materials available for rhinoplasty exceed NIH-recommended reading levels, which may prevent appropriate decision-making in patients considering these types of surgery. Outcomes of this study identify that Plastic Surgeons should be cognizant of available online patient materials and make efforts to develop and provide more appropriate materials. Readability results can also contribute to marketing strategy and attracting a more widespread interest in the procedure. PMID:29651397

  4. The Readability of AAOS Patient Education Materials: Evaluating the Progress Since 2008.

    PubMed

    Roberts, Heather; Zhang, Dafang; Dyer, George S M

    2016-09-07

    The Internet has become a major resource for patients; however, patient education materials are frequently written at relatively high levels of reading ability. The purpose of this study was to evaluate the readability of patient education materials on the American Academy of Orthopaedic Surgeons (AAOS) web site. Readability scores were calculated for all patient education articles on the AAOS web site using 5 algorithms: Flesch Reading Ease, Flesch-Kincaid Grade Level, SMOG (Simple Measure of Gobbledygook) Grade, Coleman-Liau Index, and Gunning-Fog Index. The mean readability scores were compared across the anatomic categories to which they pertained. Using a liberal measure of readability, the Flesch-Kincaid Grade Level, 3.9% of articles were written at or below the recommended sixth-grade reading level, and 84% of the articles were written above the eighth-grade reading level. Articles in the present study had a lower mean Flesch-Kincaid Grade Level than those available in 2008 (p < 0.00005). Articles categorized as "Hand & Wrist" or "Foot & Ankle" had significantly lower mean Flesch-Kincaid Grade Level scores than the mean for all categories (p < 0.0005). Regardless of the algorithm used, the mean readability levels of AAOS articles are higher than generally recommended. Although the mean Flesch-Kincaid Grade Level was lower in the present study than it was in 2008, a need remains to improve the readability of AAOS patient education articles. Ensuring that online patient education materials are written at an appropriate reading grade level would be expected to improve physician-patient communication. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  5. The quality and readability of online consumer information about gynecologic cancer.

    PubMed

    Sobota, Aleksandra; Ozakinci, Gozde

    2015-03-01

    The Internet has become an important source of health-related information for consumers, among whom younger women constitute a notable group. The aims of this study were (1) to evaluate the quality and readability of online information about gynecologic cancer using validated instruments and (2) to relate the quality of information to its readability. Using the Alexa Rank, we obtained a list of 35 Web pages providing information about 7 gynecologic malignancies. These were assessed using the Health on the Net (HON) seal of approval, the Journal of the American Medical Association (JAMA) benchmarks, and the DISCERN instrument. Flesch readability score was calculated for sections related to symptoms and signs and treatment. Less than 30% of the Web pages displayed the HON seal or achieved all JAMA benchmarks. The majority of the treatment sections were of moderate to high quality according to the DISCERN. There was no significant relationship between the presence of the HON seal and readability. Web pages achieving all JAMA benchmarks were significantly more difficult to read and understand than Web pages that missed any of the JAMA benchmarks. Treatment-related content of moderate to high quality as assessed by the DISCERN had a significantly better readability score than the low-quality content. The online information about gynecologic cancer provided by the most frequently visited Web pages is of variable quality and in general difficult to read and understand. The relationship between the quality and readability remains unclear. Health care providers should direct their patients to reliable material online because patients consider the Internet as an important source of information.

  6. Use of Existing CAD Models for Radiation Shielding Analysis

    NASA Technical Reports Server (NTRS)

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  7. Most American Academy of Orthopaedic Surgeons' online patient education material exceeds average patient reading level.

    PubMed

    Eltorai, Adam E M; Sharma, Pranav; Wang, Jing; Daniels, Alan H

    2015-04-01

    Advancing health literacy has the potential to improve patient outcomes. The American Academy of Orthopaedic Surgeons' (AAOS) online patient education materials serve as a tool to improve health literacy for orthopaedic patients; however, it is unknown whether the materials currently meet the National Institutes of Health/American Medical Association's recommended sixth grade readability guidelines for health information or the mean US adult reading level of eighth grade. The purposes of this study were (1) to evaluate the mean grade level readability of online AAOS patient education materials; and (2) to determine what proportion of the online materials exceeded recommended (sixth grade) and mean US (eighth grade) reading level. Reading grade levels for 99.6% (260 of 261) of the online patient education entries from the AAOS were analyzed using the Flesch-Kincaid formula built into Microsoft Word software. Mean grade level readability of the AAOS patient education materials was 9.2 (SD ± 1.6). Two hundred fifty-one of the 260 articles (97%) had a readability score above the sixth grade level. The readability of the AAOS articles exceeded the sixth grade level by an average of 3.2 grade levels. Of the 260 articles, 210 (81%) had a readability score above the eighth grade level, which is the average reading level of US adults. Most of the online patient education materials from the AAOS had readability levels that are far too advanced for many patients to comprehend. Efforts to adjust the readability of online education materials to the needs of the audience may improve the health literacy of orthopaedic patients. Patient education materials can be made more comprehensible through use of simpler terms, shorter sentences, and the addition of pictures. More broadly, all health websites, not just those of the AAOS, should aspire to be comprehensible to the typical reader.

  8. Inflammatory bowel disease: An evaluation of health information on the internet.

    PubMed

    Azer, Samy A; AlOlayan, Thekra I; AlGhamdi, Malak A; AlSanea, Malak A

    2017-03-07

    To evaluate the quality and accuracy of websites written to the public on inflammatory bowel disease (IBD) (Crohn's disease and ulcerative colitis) and assess their readability level. Google™, Bing™, and Yahoo™ search engines were searched independently by three researchers in December 2014. Only English-language websites were selected on the basis of predetermined inclusion and exclusion criteria. Researchers independently evaluated the quality of each website by using the DISCERN and the HONcode instruments. The readability levels were calculated using two formulas; the Flesch-Kincaid Grade Level Index, and the Coleman-Liau Readability Index. The agreement between the evaluators was calculated using Cohen kappa coefficient. Eighty-four websites were finally identified. Scores varied from a minimum DISCERN score of 18 to a maximum of 68 [mean ± SD, 42.2 ± 10.7; median = 41.5, interquartile range, interquartile range (IQR) = 15.8] and a minimum score of HONcode of 0.14 and a maximum of 0.95 (mean ± SD, 0.16 ± 0.19; median = 0.45, IQR = 0.29). Most of these websites were reviewed in 2014 and 2015 ( n = 51). The creators of these websites were: universities and research centers ( n = 25, 30%), foundations and associations ( n = 15, 18%), commercial and pharmaceutical companies ( n = 25, 30%), charities and volunteer work ( n = 9, 10%), and non-university educational bodies ( n = 10, 12%). The Flesch-Kincaid Grade Level readability score (mean ± SD) was 11.9 ± 2.4 and the Coleman-Liau Readability Index score was 12.6 ± 1.5. Significant correlation was found between the two readability scores (R 2 = 0.509, P = 0.001). The overall agreement between evaluators measured by Cohen kappa coefficient was in the range of 0.804-0.876; rated as "Good". The DISCERN and the HONcode scores of websites varied and the readability levels of most websites were above the public readability level. The study highlights the areas that need further improvement and development in patient education online materials about IBD.

  9. Assessing the Readability of Online Information About Hip Arthroscopy.

    PubMed

    Mehta, Manish P; Swindell, Hasani W; Westermann, Robert W; Rosneck, James T; Lynch, T Sean

    2018-04-06

    To investigate the current readability of online information pertaining to hip arthroscopy. The terms "hip arthroscopy" and "hip scope" were entered into the advanced search functions of Google, Yahoo!, and Bing on March 25, 2017, and results from the first 3 pages were analyzed. Results were required to be unique, accessible websites with information about hip arthroscopy conveyed primarily via analyzable text. Two reviewers applied inclusion criteria to the initial 97 results, discussing to reach consensus in cases of disagreement. Overall, 60 unique results were reviewed with 48 meeting inclusion criteria. Websites were categorized as physician-sponsored, academic, commercial, governmental and nonprofit organization (NPO), or unspecified. Readability was measured via 6 different indices: the Flesch-Kincaid grade level (FKGL), Flesch Reading Ease (FRE), Gunning Fog Score, SMOG Index, Coleman-Liau Index (CLI), and Automated Readability Index (ARI) along with an average grade level and readability classification score. Forty-eight unique websites were assessed for readability, with physician-sponsored webpages composing the majority (47.92%) followed by academic sources (35.42%). The webpages' average grade level, incorporating information from all 6 metrics, was 12.79 ± 1.98. The current readability of online information pertaining to hip arthroscopy is at an inappropriately high reading level compared with the sixth-grade level recommended by the American Medical Association and National Institutes of Health, thus introducing significant barriers to understanding for many patients. Online materials should be edited to reduce word and sentence length and complexity, use simpler terms, and minimize use of passive voice to facilitate patient knowledge acquisition and understanding of online information about hip arthroscopy. This study shows that the current readability of online information on hip arthroscopy exceeds the suggested sixth-grade reading level. It also emphasizes the need for simplifying written materials and offers specific suggestions on doing so to increase accessibility of information for patients. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Assessing Online Patient Education Readability for Spine Surgery Procedures.

    PubMed

    Long, William W; Modi, Krishna D; Haws, Brittany E; Khechen, Benjamin; Massel, Dustin H; Mayo, Benjamin C; Singh, Kern

    2018-03-01

    Increased patient reliance on Internet-based health information has amplified the need for comprehensible online patient education articles. As suggested by the American Medical Association and National Institute of Health, spine fusion articles should be written for a 4th-6th-grade reading level to increase patient comprehension, which may improve postoperative outcomes. The purpose of this study is to determine the readability of online health care education information relating to anterior cervical discectomy and fusion (ACDF) and lumbar fusion procedures. Online health-education resource qualitative analysis. Three search engines were utilized to access patient education articles for common cervical and lumbar spine procedures. Relevant articles were analyzed for readability using Readability Studio Professional Edition software (Oleander Software Ltd). Articles were stratified by organization type as follows: General Medical Websites (GMW), Healthcare Network/Academic Institutions (HNAI), and Private Practices (PP). Thirteen common readability tests were performed with the mean readability of each compared between subgroups using analysis of variance. ACDF and lumbar fusion articles were determined to have a mean readability of 10.7±1.5 and 11.3±1.6, respectively. GMW, HNAI, and PP subgroups had a mean readability of 10.9±2.9, 10.7±2.8, and 10.7±2.5 for ACDF and 10.9±3.0, 10.8±2.9, and 11.6±2.7 for lumbar fusion articles. Of 310 total articles, only 6 (3 ACDF and 3 lumbar fusion) were written for comprehension below a 7th-grade reading level. Current online literature from medical websites containing information regarding ACDF and lumbar fusion procedures are written at a grade level higher than the suggested guidelines. Therefore, current patient education articles should be revised to accommodate the average reading level in the United States and may result in improved patient comprehension and postoperative outcomes.

  11. The readability of psychosocial wellness patient resources: improving surgical outcomes.

    PubMed

    Kugar, Meredith A; Cohen, Adam C; Wooden, William; Tholpady, Sunil S; Chu, Michael W

    2017-10-01

    Patient education is increasingly accessed with online resources and is essential for patient satisfaction and clinical outcomes. The average American adult reads at a seventh grade level, and the National Institute of Health (NIH) and the American Medical Association (AMA) recommend that information be written at a sixth-grade reading level. Health literacy plays an important role in the disease course and outcomes of all patients, including those with depression and likely other psychiatric disorders, although this is an area in need of further study. The purpose of this study was to collect and analyze written, online mental health resources on the Veterans Health Administration (VA) website, and other websites, using readability assessment instruments. An internet search was performed to identify written patient education information regarding mental health from the VA (the VA Mental Health Website) and top-rated psychiatric hospitals. Seven mental health topics were included in the analysis: generalized anxiety disorder, bipolar, major depressive disorder, posttraumatic stress disorder, schizophrenia, substance abuse, and suicide. Readability analyses were performed using the Gunning Fog Index, the Flesch-Kincaid Grade Level, the Coleman-Liau Index, the SMOG Readability Formula, and the Automated Readability Index. These scores were then combined into a Readability Consensus score. A two-tailed t-test was used to compare the mean values, and statistical significance was set at P < 0.05. Twelve of the best hospitals for psychiatry 2016-2017 were identified. Nine had educational material. Six of the nine cited the same resource, The StayWell Company, LLC (StayWell Company, LLC; Yardley, PA), for at least one of the mental health topics analyzed. The VA mental health website (http://www.mentalhealth.va.gov) had a significantly higher readability consensus than six of the top psychiatric hospitals (P < 0.05, P = 0.0067, P = 0.019, P = 0.041, P = 0.0093, P = 0.0054, and P = 0.0093). The overall average readability consensus for mental health information on all websites analyzed was 9.52. Online resources for mental health disorders are more complex than recommended by the NIH and AMA. Efforts to improve readability of mental health and psychosocial wellness resources could benefit patient understanding and outcomes, especially in patients with lower literacy. Surgical outcomes are correlated with patient mental health and psychosocial wellness and thus can be improved with more appropriate levels of readability of psychosocial wellness resources. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Real time explosive hazard information sensing, processing, and communication for autonomous operation

    DOEpatents

    Versteeg, Roelof J; Few, Douglas A; Kinoshita, Robert A; Johnson, Doug; Linda, Ondrej

    2015-02-24

    Methods, computer readable media, and apparatuses provide robotic explosive hazard detection. A robot intelligence kernel (RIK) includes a dynamic autonomy structure with two or more autonomy levels between operator intervention and robot initiative A mine sensor and processing module (ESPM) operating separately from the RIK perceives environmental variables indicative of a mine using subsurface perceptors. The ESPM processes mine information to determine a likelihood of a presence of a mine. A robot can autonomously modify behavior responsive to an indication of a detected mine. The behavior is modified between detection of mines, detailed scanning and characterization of the mine, developing mine indication parameters, and resuming detection. Real time messages are passed between the RIK and the ESPM. A combination of ESPM bound messages and RIK bound messages cause the robot platform to switch between modes including a calibration mode, the mine detection mode, and the mine characterization mode.

  13. Real time explosive hazard information sensing, processing, and communication for autonomous operation

    DOEpatents

    Versteeg, Roelof J.; Few, Douglas A.; Kinoshita, Robert A.; Johnson, Douglas; Linda, Ondrej

    2015-12-15

    Methods, computer readable media, and apparatuses provide robotic explosive hazard detection. A robot intelligence kernel (RIK) includes a dynamic autonomy structure with two or more autonomy levels between operator intervention and robot initiative A mine sensor and processing module (ESPM) operating separately from the RIK perceives environmental variables indicative of a mine using subsurface perceptors. The ESPM processes mine information to determine a likelihood of a presence of a mine. A robot can autonomously modify behavior responsive to an indication of a detected mine. The behavior is modified between detection of mines, detailed scanning and characterization of the mine, developing mine indication parameters, and resuming detection. Real time messages are passed between the RIK and the ESPM. A combination of ESPM bound messages and RIK bound messages cause the robot platform to switch between modes including a calibration mode, the mine detection mode, and the mine characterization mode.

  14. The Evaluation of High School Geography 9 and High School Geography 11 Text Books with Some Formulas of Readability

    ERIC Educational Resources Information Center

    Gecit, Yilmaz

    2010-01-01

    The purpose of this study is to evaluate readability of 9th and 11th grade geography text-books currently used in schools. As known, one of the most fundamental features in a text-book is the readability of the text by students. In addition, it is also very important that the fluency and suitability of books match age level. In this study, the…

  15. Handling knowledge via Concept Maps: a space weather use case

    NASA Astrophysics Data System (ADS)

    Messerotti, Mauro; Fox, Peter

    Concept Maps (Cmaps) are powerful means for knowledge coding in graphical form. As flexible software tools exist to manipulate the knowledge embedded in Cmaps in machine-readable form, such complex entities are suitable candidates not only for the representation of ontologies and semantics in Virtual Observatory (VO) architectures, but also for knowledge handling and knowledge discovery. In this work, we present a use case relevant to space weather applications and we elaborate on its possible implementation and adavanced use in Semantic Virtual Observatories dedicated to Sun-Earth Connections. This analysis was carried out in the framework of the Electronic Geophysical Year (eGY) and represents an achievement synergized by the eGY Virtual Observatories Working Group.

  16. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool.

    PubMed

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc . joseph.brown@pnnl.gov. © The Author(s) 2017. Published by Oxford University Press.

  17. Real-time, interactive animation of deformable two- and three-dimensional objects

    DOEpatents

    Desbrun, Mathieu; Schroeder, Peter; Meyer, Mark; Barr, Alan H.

    2003-06-03

    A method of updating in real-time the locations and velocities of mass points of a two- or three-dimensional object represented by a mass-spring system. A modified implicit Euler integration scheme is employed to determine the updated locations and velocities. In an optional post-integration step, the updated locations are corrected to preserve angular momentum. A processor readable medium and a network server each tangibly embodying the method are also provided. A system comprising a processor in combination with the medium, and a system comprising the server in combination with a client for accessing the server over a computer network, are also provided.

  18. Readability of patient education materials from the American Academy of Orthopaedic Surgeons and Pediatric Orthopaedic Society of North America web sites.

    PubMed

    Badarudeen, Sameer; Sabharwal, Sanjeev

    2008-01-01

    While experts recommend that the readability of patient education materials should be less than the sixth grade level, the available information pertaining to orthopaedic diseases may be excessively complex for some to read and comprehend. The Flesch-Kincaid grade level is the most widely used tool to evaluate the readability score of a given text, with a lower grade level suggesting easier readability. The goal of our study was to assess the readability of pediatric orthopaedic patient education materials that were developed by the American Academy of Orthopaedic Surgeons (AAOS) and the Pediatric Orthopaedic Society of North America (POSNA) and were accessible to the general public through the Internet. All articles from the "Children" section of the patient education library, "Your Orthopaedic Connection," on the AAOS web site and the "Parent/Patient" section on the POSNA web site were identified. The Flesch-Kincaid grade level of each article was determined with use of Microsoft Office Word software. The mean grade levels of articles that were available in 2001 were compared with those accessible in 2007. Fifty-seven unique articles were available in 2007 on both web sites compared with twenty-five articles available in 2001. The readability score of only one (2%) of the currently available articles was less than sixth grade level. The mean Flesch-Kincaid grade level of the currently available articles was 8.9 compared with 8.7 for the articles available in 2001 (p = 0.71). Our findings suggest that most of the pediatric orthopaedic patient education materials available on the AAOS and POSNA web sites have readability scores that may be too high, making comprehension difficult for a substantial portion of the United States population.

  19. Readability and Content Assessment of Informed Consent Forms for Phase II-IV Clinical Trials in China

    PubMed Central

    Wen, Gaiyan; Liu, Xinchun; Huang, Lihua; Shu, Jingxian; Xu, Nana; Chen, Ruifang; Huang, Zhijun; Yang, Guoping; Wang, Xiaomin; Xiang, Yuxia; Lu, Yao; Yuan, Hong

    2016-01-01

    Purpose To explore the readability and content integrity of informed consent forms (ICFs) used in China and to compare the quality of Chinese local ICFs with that of international ICFs. Methods The length, readability and content of 155 consent documents from phase II-IV drug clinical trials from the Third Xiangya Hospital Ethics Committee from November 2009 to January 2015 were evaluated. Reading difficulty was tested using a readability formula adapted for the Chinese language. An ICF checklist containing 27 required elements was successfully constructed to evaluate content integrity. The description of alternatives to participation was assessed. The quality of ICFs from different sponsorships were also compared. Results Among the 155 evaluable trials, the ICFs had a median length of 5286 words, corresponding to 7 pages. The median readability score was 4.31 (4.02–4.41), with 63.9% at the 2nd level and 36.1% at the 3rd level. Five of the 27 elements were frequently neglected. The average score for the description of alternatives to participation was 1.06, and 27.7% of the ICFs did not mention any alternatives. Compared with Chinese local ICFs, international ICFs were longer, more readable and contained more of the required elements (P < 0.05). Conclusion The ICFs used in China were difficult to read for most participants. These forms had poor description of alternatives to participation, and failed to provide a high degree of information disclosure, including an explanation of informed consent, follow-up processing of the data/sample, inclusion/exclusion criteria, double blinding, and unpredictable risks. International ICFs had better readability and content integrity than Chinese local ICFs. More efforts should thus be made to improve the quality of consent documents in China. PMID:27701471

  20. Readability and Content Assessment of Informed Consent Forms for Phase II-IV Clinical Trials in China.

    PubMed

    Wen, Gaiyan; Liu, Xinchun; Huang, Lihua; Shu, Jingxian; Xu, Nana; Chen, Ruifang; Huang, Zhijun; Yang, Guoping; Wang, Xiaomin; Xiang, Yuxia; Lu, Yao; Yuan, Hong

    2016-01-01

    To explore the readability and content integrity of informed consent forms (ICFs) used in China and to compare the quality of Chinese local ICFs with that of international ICFs. The length, readability and content of 155 consent documents from phase II-IV drug clinical trials from the Third Xiangya Hospital Ethics Committee from November 2009 to January 2015 were evaluated. Reading difficulty was tested using a readability formula adapted for the Chinese language. An ICF checklist containing 27 required elements was successfully constructed to evaluate content integrity. The description of alternatives to participation was assessed. The quality of ICFs from different sponsorships were also compared. Among the 155 evaluable trials, the ICFs had a median length of 5286 words, corresponding to 7 pages. The median readability score was 4.31 (4.02-4.41), with 63.9% at the 2nd level and 36.1% at the 3rd level. Five of the 27 elements were frequently neglected. The average score for the description of alternatives to participation was 1.06, and 27.7% of the ICFs did not mention any alternatives. Compared with Chinese local ICFs, international ICFs were longer, more readable and contained more of the required elements (P < 0.05). The ICFs used in China were difficult to read for most participants. These forms had poor description of alternatives to participation, and failed to provide a high degree of information disclosure, including an explanation of informed consent, follow-up processing of the data/sample, inclusion/exclusion criteria, double blinding, and unpredictable risks. International ICFs had better readability and content integrity than Chinese local ICFs. More efforts should thus be made to improve the quality of consent documents in China.

  1. Readability Assessment of Patient Information about Lymphedema and Its Treatment.

    PubMed

    Seth, Akhil K; Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2016-02-01

    Patient use of online resources for health information is increasing, and access to appropriately written information has been associated with improved patient satisfaction and overall outcomes. The American Medical Association and the National Institutes of Health recommend that patient materials be written at a sixth-grade reading level. In this study, the authors simulated a patient search of online educational content for lymphedema and evaluated readability. An online search for the term "lymphedema" was performed, and the first 12 hits were identified. User and location filters were disabled and sponsored results were excluded. Patient information from each site was downloaded and formatted into plain text. Readability was assessed using established tests: Coleman-Liau, Flesch-Kincaid, Flesch Reading Ease Index, FORCAST Readability Formula, Fry Graph, Gunning Fog Index, New Dale-Chall Formula, New Fog Count, Raygor Readability Estimate, and Simple Measure of Gobbledygook Readability Formula. There were 152 patient articles downloaded; the overall mean reading level was 12.6. Individual website reading levels ranged from 9.4 (cancer.org) to 16.7 (wikipedia.org). There were 36 articles dedicated to conservative treatments for lymphedema; surgical treatment was mentioned in nine articles across four sites. The average reading level for conservative management was 12.7, compared with 15.6 for surgery (p < 0.001). Patient information found through an Internet search for lymphedema is too difficult for many American adults to read. Websites queried had a range of readability, and surgeons should direct patients to sites appropriate for their level. There is limited information about surgical treatment available on the most popular sites; this information is significantly harder to read than sections on conservative measures.

  2. Readability of spine-related patient education materials from subspecialty organization and spine practitioner websites.

    PubMed

    Vives, Michael; Young, Lyle; Sabharwal, Sanjeev

    2009-12-01

    Analysis of spine-related websites available to the general public. To assess the readability of spine-related patient educational materials available on professional society and individual surgeon or practice based websites. The Internet has become a valuable source of patient education material. A significant percentage of patients, however, find this Internet based information confusing. Healthcare experts recommend that the readability of patient education material be less than the sixth grade level. The Flesch-Kincaid grade level is the most widely used method to evaluate the readability score of textual material, with lower scores suggesting easier readability. We conducted an Internet search of all patient education documents on the North American Spine Society (NASS), American Association of Neurological Surgeons (AANS), the American Academy of Orthopaedic Surgeons (AAOS), and a sample of 10 individual surgeon or practice based websites. The Flesch-Kincaid grade level of each article was calculated using widely available Microsoft Office Word software. The mean grade level of articles on the various professional society and individual/practice based websites were compared. A total of 121 articles from the various websites were available and analyzed. All 4 categories of websites had mean Flesch-Kincaid grade levels greater than 10. Only 3 articles (2.5%) were found to be at or below the sixth grade level, the recommended readability level for adult patients in the United States. There were no significant differences among the mean Flesch-Kincaid grade levels from the AAOS, NASS, AANS, and practice-based web-sites (P = 0.065, ANOVA). Our findings suggest that most of the Spine-related patient education materials on professional society and practice-based websites have readability scores that may be too high, making comprehension difficult for a substantial portion of the United States adult population.

  3. The Readability of Electronic Cigarette Health Information and Advice: A Quantitative Analysis of Web-Based Information.

    PubMed

    Park, Albert; Zhu, Shu-Hong; Conway, Mike

    2017-01-06

    The popularity and use of electronic cigarettes (e-cigarettes) has increased across all demographic groups in recent years. However, little is currently known about the readability of health information and advice aimed at the general public regarding the use of e-cigarettes. The objective of our study was to examine the readability of publicly available health information as well as advice on e-cigarettes. We compared information and advice available from US government agencies, nongovernment organizations, English speaking government agencies outside the United States, and for-profit entities. A systematic search for health information and advice on e-cigarettes was conducted using search engines. We manually verified search results and converted to plain text for analysis. We then assessed readability of the collected documents using 4 readability metrics followed by pairwise comparisons of groups with adjustment for multiple comparisons. A total of 54 documents were collected for this study. All 4 readability metrics indicate that all information and advice on e-cigarette use is written at a level higher than that recommended for the general public by National Institutes of Health (NIH) communication guidelines. However, health information and advice written by for-profit entities, many of which were promoting e-cigarettes, were significantly easier to read. A substantial proportion of potential and current e-cigarette users are likely to have difficulty in fully comprehending Web-based health information regarding e-cigarettes, potentially hindering effective health-seeking behaviors. To comply with NIH communication guidelines, government entities and nongovernment organizations would benefit from improving the readability of e-cigarettes information and advice. ©Albert Park, Shu-Hong Zhu, Mike Conway. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 06.01.2017.

  4. Readability assessment of Internet-based patient education materials related to endoscopic sinus surgery.

    PubMed

    Cherla, Deepa V; Sanghvi, Saurin; Choudhry, Osamah J; Liu, James K; Eloy, Jean Anderson

    2012-08-01

    Numerous professional societies, clinical practices, and hospitals provide Internet-based patient education materials (PEMs) to the general public, but not all of this information is written at a reading level appropriate for the average patient. The National Institutes of Health and the US Department of Health and Human Services recommend that PEMs be written at or below the sixth-grade level. Our purpose was to assess the readability of endoscopic sinus surgery (ESS)-related PEMs available on the Internet and compare readability levels of PEMs provided by three sources: professional societies, clinical practices, and hospitals. A descriptive and correlational design was used for this study. The readability of 31 ESS-related PEMs was assessed with four different readability indices: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG). Averages were evaluated against national recommendations and between each source using analysis of variance and t tests. The majority of PEMs (96.8%) were written above the recommended sixth-grade reading level, based on FKGL (P < .001). Only one article (3.2%) had an FKGL at or below the sixth-grade level. The mean readability values were: FRES 47.1 ± 13.4, FKGL 10.7 ± 2.4, SMOG 13.7 ± 1.6, and Gunning FOG 12.4 ± 2.7. Current Internet-based PEMs related to ESS, regardless of source type, were written well above the recommended sixth-grade level. Materials from the hospitals/university-affiliated websites had lower readability scores, but were still above recommended levels. Web-based PEMs pertaining to ESS should be written with the average patient in mind. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  5. Automatic Ammunition Identification Technology Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weil, B.

    1993-01-01

    The Automatic Ammunition Identification Technology (AAIT) Project is an activity of the Robotics Process Systems Division at the Oak Ridge National Laboratory (ORNL) for the US Army's Project Manager-Ammunition Logistics (PM-AMMOLOG) at the Picatinny Arsenal in Picatinny, New Jersey. The project objective is to evaluate new two-dimensional bar code symbologies for potential use in ammunition logistics systems and automated reloading equipment. These new symbologies are a significant improvement over typical linear bar codes since machine-readable alphanumeric messages up to 2000 characters long are achievable. These compressed data symbologies are expected to significantly improve logistics and inventory management tasks and permitmore » automated feeding and handling of ammunition to weapon systems. The results will be increased throughout capability, better inventory control, reduction of human error, lower operation and support costs, and a more timely re-supply of various weapon systems. This paper will describe the capabilities of existing compressed data symbologies and the symbol testing activities being conducted at ORNL for the AAIT Project.« less

  6. Automatic Ammunition Identification Technology Project. Ammunition Logistics Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weil, B.

    1993-03-01

    The Automatic Ammunition Identification Technology (AAIT) Project is an activity of the Robotics & Process Systems Division at the Oak Ridge National Laboratory (ORNL) for the US Army`s Project Manager-Ammunition Logistics (PM-AMMOLOG) at the Picatinny Arsenal in Picatinny, New Jersey. The project objective is to evaluate new two-dimensional bar code symbologies for potential use in ammunition logistics systems and automated reloading equipment. These new symbologies are a significant improvement over typical linear bar codes since machine-readable alphanumeric messages up to 2000 characters long are achievable. These compressed data symbologies are expected to significantly improve logistics and inventory management tasks andmore » permit automated feeding and handling of ammunition to weapon systems. The results will be increased throughout capability, better inventory control, reduction of human error, lower operation and support costs, and a more timely re-supply of various weapon systems. This paper will describe the capabilities of existing compressed data symbologies and the symbol testing activities being conducted at ORNL for the AAIT Project.« less

  7. Avatar DNA Nanohybrid System in Chip-on-a-Phone

    NASA Astrophysics Data System (ADS)

    Park, Dae-Hwan; Han, Chang Jo; Shul, Yong-Gun; Choy, Jin-Ho

    2014-05-01

    Long admired for informational role and recognition function in multidisciplinary science, DNA nanohybrids have been emerging as ideal materials for molecular nanotechnology and genetic information code. Here, we designed an optical machine-readable DNA icon on microarray, Avatar DNA, for automatic identification and data capture such as Quick Response and ColorZip codes. Avatar icon is made of telepathic DNA-DNA hybrids inscribed on chips, which can be identified by camera of smartphone with application software. Information encoded in base-sequences can be accessed by connecting an off-line icon to an on-line web-server network to provide message, index, or URL from database library. Avatar DNA is then converged with nano-bio-info-cogno science: each building block stands for inorganic nanosheets, nucleotides, digits, and pixels. This convergence could address item-level identification that strengthens supply-chain security for drug counterfeits. It can, therefore, provide molecular-level vision through mobile network to coordinate and integrate data management channels for visual detection and recording.

  8. Avatar DNA Nanohybrid System in Chip-on-a-Phone

    PubMed Central

    Park, Dae-Hwan; Han, Chang Jo; Shul, Yong-Gun; Choy, Jin-Ho

    2014-01-01

    Long admired for informational role and recognition function in multidisciplinary science, DNA nanohybrids have been emerging as ideal materials for molecular nanotechnology and genetic information code. Here, we designed an optical machine-readable DNA icon on microarray, Avatar DNA, for automatic identification and data capture such as Quick Response and ColorZip codes. Avatar icon is made of telepathic DNA-DNA hybrids inscribed on chips, which can be identified by camera of smartphone with application software. Information encoded in base-sequences can be accessed by connecting an off-line icon to an on-line web-server network to provide message, index, or URL from database library. Avatar DNA is then converged with nano-bio-info-cogno science: each building block stands for inorganic nanosheets, nucleotides, digits, and pixels. This convergence could address item-level identification that strengthens supply-chain security for drug counterfeits. It can, therefore, provide molecular-level vision through mobile network to coordinate and integrate data management channels for visual detection and recording. PMID:24824876

  9. Documentation for the machine-readable character coded version of the SKYMAP catalogue

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1981-01-01

    The SKYMAP catalogue is a compilation of astronomical data prepared primarily for purposes of attitude guidance for satellites. In addition to the SKYMAP Master Catalogue data base, a software package of data base management and utility programs is available. The tape version of the SKYMAP Catalogue, as received by the Astronomical Data Center (ADC), contains logical records consisting of a combination of binary and EBCDIC data. Certain character coded data in each record are redundant in that the same data are present in binary form. In order to facilitate wider use of all SKYMAP data by the astronomical community, a formatted (character) version was prepared by eliminating all redundant character data and converting all binary data to character form. The character version of the catalogue is described. The document is intended to fully describe the formatted tape so that users can process the data problems and guess work; it should be distributed with any character version of the catalogue.

  10. Documentation for the machine-readable version of the Henry Draper Catalogue (edition 1985)

    NASA Technical Reports Server (NTRS)

    Roman, N. G.; Warren, W. H., Jr.

    1985-01-01

    An updated, corrected and extended machine-readable version of the catalog is described. Published and unpublished errors discovered in the previous version was corrected; letters indicating supplemental stars in the BD have been moved to a new byte to distinguish them from double-star components; and the machine readable portion of The Henry Draper Extension (HDE) (HA 100) was converted to the same format as the main catalog, with additional data added as necessary.

  11. A readability assessment of online stroke information.

    PubMed

    Sharma, Nikhil; Tridimas, Andreas; Fitzsimmons, Paul R

    2014-07-01

    Patients and carers increasingly access the Internet as a source of health information. Poor health literacy is extremely common and frequently limits patient's comprehension of health care information literature. We aimed to assess the readability of online consumer-orientated stroke information using 2 validated readability measures. The 100 highest Google ranked consumer-oriented stroke Web pages were assessed for reading difficulty using the Flesch-Kincaid and Simple Measure of Gobbledygook (SMOG) formulae. None of the included Web pages complied with the current readability guidelines when readability was measured using the gold standard SMOG formula. Mean Flesch-Kincaid grade level was 10.4 (95% confidence interval [CI] 9.97-10.9) and mean SMOG grade 12.1 (95% CI 11.7-12.4). Over half of the Web pages were produced at graduate reading levels or above. Not-for-profit Web pages were significantly easier to read (P=.0006). The Flesch-Kincaid formula significantly underestimated reading difficulty, with a mean underestimation of 1.65 grades (95% CI 1.49-1.81), P<.0001. Most consumer-orientated stroke information Web sites require major text revision to comply with readability guidelines and to be comprehensible to the average patient. The Flesch-Kincaid formula significantly underestimates reading difficulty, and SMOG should be used as the measure of choice. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  12. [Hygienic Assesment of Educational Texts: Methodical Approaches and Evaluation of Difficulties for Children of Secondary Textbooks].

    PubMed

    Kuchma, V R; Tkachuk, E A

    2015-01-01

    The understandability and readability of the text are significant indicators of evaluation of textbooks. The aim of the study - rationale of improving the readability and understandability of textbooks. 60 modern textbooks for 5-11th classes on History, Physics, Biology and 23 textbooks of 1960-1980's edition. Flesch index was used to assess the readability, Fogh index - to evaluate understandability. The readability and understandability of texts in textbooks of 1960-1980's and modern editions have no differences and show the same complexity of old and modern textbooks for students. The indicator of understandability of textbooks for primary classes corresponds to age norm and is 4.4±0.2 points. The indicator of readability for these books is less age norm and is 53.8±2.9 points, which increases the physiological cost of educational activities of children of primary school age. Children's readability and understandability of school textbooks are a significant factor of intensity of training activities and can be objectively assessed by Flesch and Fogh indices, that it is appropriate for an objective hygienic assessment of the tension of the educational activities for children. The main direction of optimization of the tension of educational activity is to reduce the intellectual and emotional loads in children by increasing the easiness of reading textbooks due to their compliance with the age peculiarities of students.

  13. Readability of Self-Report Alcohol Misuse Measures

    PubMed Central

    McHugh, R Kathryn; Sugarman, Dawn E; Kaufman, Julia S; Park, Sara; Weiss, Roger D; Greenfield, Shelly F

    2014-01-01

    Objective: Self-report measures of alcohol misuse and alcohol use disorders are valuable assessment tools for both research and clinical practice settings. However, readability is often overlooked when establishing the validity of these measures, which may result in measures written at a reading-grade level that is higher than the ability level of many potential respondents. The aim of the current study was to estimate the reading-grade level of validated measures of alcohol misuse and associated problems. Method: A total of 45 measures were identified, and reading-grade level was calculated using three validated readability formulas. Results: The majority of measures were written above the recommended reading-grade level for patient materials (5th–6th grade), with particularly poor readability for measure instructions. Conclusions: Given that many self-report alcohol misuse measures are written at a high reading-grade level, the consideration of readability is important when selecting measures for use in research and practice settings. Moreover, the development or modification of measures to target low-literacy populations may facilitate the broader applicability of these instruments. PMID:24650827

  14. The Modified Cognitive Constructions Coding System: Reliability and Validity Assessments

    ERIC Educational Resources Information Center

    Moran, Galia S.; Diamond, Gary M.

    2006-01-01

    The cognitive constructions coding system (CCCS) was designed for coding client's expressed problem constructions on four dimensions: intrapersonal-interpersonal, internal-external, responsible-not responsible, and linear-circular. This study introduces, and examines the reliability and validity of, a modified version of the CCCS--a version that…

  15. Retrofitting the AutoBayes Program Synthesis System with Concrete Syntax

    NASA Technical Reports Server (NTRS)

    Fischer, Bernd; Visser, Eelco

    2004-01-01

    AutoBayes is a fully automatic, schema-based program synthesis system for statistical data analysis applications. Its core component is a schema library. i.e., a collection of generic code templates with associated applicability constraints which are instantiated in a problem-specific way during synthesis. Currently, AutoBayes is implemented in Prolog; the schemas thus use abstract syntax (i.e., Prolog terms) to formulate the templates. However, the conceptual distance between this abstract representation and the concrete syntax of the generated programs makes the schemas hard to create and maintain. In this paper we describe how AutoBayes is retrofitted with concrete syntax. We show how it is integrated into Prolog and describe how the seamless interaction of concrete syntax fragments with AutoBayes's remaining legacy meta-programming kernel based on abstract syntax is achieved. We apply the approach to gradually mitigate individual schemas without forcing a disruptive migration of the entire system to a different First experiences show that a smooth migration can be achieved. Moreover, it can result in a considerable reduction of the code size and improved readability of the code. In particular, abstracting out fresh-variable generation and second-order term construction allows the formulation of larger continuous fragments.

  16. Software Process Assessment (SPA)

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda H.; Sheppard, Sylvia B.; Butler, Scott A.

    1994-01-01

    NASA's environment mirrors the changes taking place in the nation at large, i.e. workers are being asked to do more work with fewer resources. For software developers at NASA's Goddard Space Flight Center (GSFC), the effects of this change are that we must continue to produce quality code that is maintainable and reusable, but we must learn to produce it more efficiently and less expensively. To accomplish this goal, the Data Systems Technology Division (DSTD) at GSFC is trying a variety of both proven and state-of-the-art techniques for software development (e.g., object-oriented design, prototyping, designing for reuse, etc.). In order to evaluate the effectiveness of these techniques, the Software Process Assessment (SPA) program was initiated. SPA was begun under the assumption that the effects of different software development processes, techniques, and tools, on the resulting product must be evaluated in an objective manner in order to assess any benefits that may have accrued. SPA involves the collection and analysis of software product and process data. These data include metrics such as effort, code changes, size, complexity, and code readability. This paper describes the SPA data collection and analysis methodology and presents examples of benefits realized thus far by DSTD's software developers and managers.

  17. Enzyme-like replication de novo in a microcontroller environment.

    PubMed

    Tangen, Uwe

    2010-01-01

    The desire to start evolution from scratch inside a computer memory is as old as computing. Here we demonstrate how viable computer programs can be established de novo in a Precambrian environment without supplying any specific instantiation, just starting with random bit sequences. These programs are not self-replicators, but act much more like catalysts. The microcontrollers used in the end are the result of a long series of simplifications. The objective of this simplification process was to produce universal machines with a human-readable interface, allowing software and/or hardware evolution to be studied. The power of the instruction set can be modified by introducing a secondary structure-folding mechanism, which is a state machine, allowing nontrivial replication to emerge with an instruction width of only a few bits. This state-machine approach not only attenuates the problems of brittleness and encoding functionality (too few bits available for coding, and too many instructions needed); it also enables the study of hardware evolution as such. Furthermore, the instruction set is sufficiently powerful to permit external signals to be processed. This information-theoretic approach forms one vertex of a triangle alongside artificial cell research and experimental research on the creation of life. Hopefully this work helps develop an understanding of how information—in a similar sense to the account of functional information described by Hazen et al.—is created by evolution and how this information interacts with or is embedded in its physico-chemical environment.

  18. A search for ultraviolet-excess objects (Kondo, Noguchi, and Maehara 1984): Documentation for the machine-readable version

    NASA Technical Reports Server (NTRS)

    Warren, Wayne H., Jr.

    1990-01-01

    A list of 1186 ultraviolet-excess objects (designated KUV) was compiled as a result of a search conducted with the 105-cm Schmidt telescope of the Kiso station of the Tokyo Astronomical Observatory. This document describes the machine readable version of the KUV survey list and presents a sample listing showing the logical records as they are recorded in the machine readable catalog. The KUV data include equatorial coordinates, magnitudes, color indices, and identifications for previously cataloged objects.

  19. Inflammatory bowel disease: An evaluation of health information on the internet

    PubMed Central

    Azer, Samy A; AlOlayan, Thekra I; AlGhamdi, Malak A; AlSanea, Malak A

    2017-01-01

    AIM To evaluate the quality and accuracy of websites written to the public on inflammatory bowel disease (IBD) (Crohn's disease and ulcerative colitis) and assess their readability level. METHODS Google™, Bing™, and Yahoo™ search engines were searched independently by three researchers in December 2014. Only English-language websites were selected on the basis of predetermined inclusion and exclusion criteria. Researchers independently evaluated the quality of each website by using the DISCERN and the HONcode instruments. The readability levels were calculated using two formulas; the Flesch-Kincaid Grade Level Index, and the Coleman-Liau Readability Index. The agreement between the evaluators was calculated using Cohen kappa coefficient. RESULTS Eighty-four websites were finally identified. Scores varied from a minimum DISCERN score of 18 to a maximum of 68 [mean ± SD, 42.2 ± 10.7; median = 41.5, interquartile range, interquartile range (IQR) = 15.8] and a minimum score of HONcode of 0.14 and a maximum of 0.95 (mean ± SD, 0.16 ± 0.19; median = 0.45, IQR = 0.29). Most of these websites were reviewed in 2014 and 2015 (n = 51). The creators of these websites were: universities and research centers (n = 25, 30%), foundations and associations (n = 15, 18%), commercial and pharmaceutical companies (n = 25, 30%), charities and volunteer work (n = 9, 10%), and non-university educational bodies (n = 10, 12%). The Flesch-Kincaid Grade Level readability score (mean ± SD) was 11.9 ± 2.4 and the Coleman-Liau Readability Index score was 12.6 ± 1.5. Significant correlation was found between the two readability scores (R2 = 0.509, P = 0.001). The overall agreement between evaluators measured by Cohen kappa coefficient was in the range of 0.804-0.876; rated as "Good". CONCLUSION The DISCERN and the HONcode scores of websites varied and the readability levels of most websites were above the public readability level. The study highlights the areas that need further improvement and development in patient education online materials about IBD. PMID:28321169

  20. Accuracy and Readability of Websites on Kidney and Bladder Cancers.

    PubMed

    Azer, Samy A; Alghofaili, Maha M; Alsultan, Rana M; Alrumaih, Najla S

    2017-03-09

    The aim of this study was to assess the scientific accuracy and the readability level of websites on kidney and bladder cancers. The search engines Google™, Yahoo™ and Bing™ were searched independently by assessors in November 2014 using the following keywords: "bladder cancer", "kidney cancer", "patient bladder cancer", "patient kidney cancer" and "bladder and kidney cancer". Only English-language websites were selected on the bases of predetermined inclusion and exclusion criteria. Assessors independently reviewed the findings and evaluated the accuracy and quality of each website by using the DISCERN and the LIDA instruments. The readability of the websites was calculated using the Flesch-Kincaid Grade Level Index and the Coleman-Liau Readability Index. Sixty-two websites were finally included in the study. The overall accuracy scores varied; for the DISCERN, the range was 28 to 76; out of 80 (mean ± SD, 47.1 ± 12.1; median = 46.0, interquartile range (IQR) = 19.2), and for the LIDA, the range was 52 to 125; out of 144 (mean ± SD, 101.9 ± 15.2; median, 103; IQR, 16.5). The creators of these websites were universities and research centres (n = 25, 40%), foundations and associations (n = 10, 16%), commercial and pharmaceutical companies (n = 13, 21%), charities and volunteer work (n = 4, 6%) and non-university educational bodies (n = 10, 16%). The readability scores (mean ± SD) were 11.2 ± 2.2 for the Flesch-Kincaid Grade Level Index and 11.2 ± 1.6 for the Coleman-Liau Readability Index. The accuracy and the quality of the websites on kidney and bladder cancers varied. In most websites, there were deficiencies in clarity of aims, presenting symptoms, investigations and treatment options. The readability matched grades 10-11 literacy levels-a level above the public readability level. The study highlights the needs for further improvement of the online information created for public and patients with kidney and bladder cancers.

  1. Modified NASA-Lewis chemical equilibrium code for MHD applications

    NASA Technical Reports Server (NTRS)

    Sacks, R. A.; Geyer, H. K.; Grammel, S. J.; Doss, E. D.

    1979-01-01

    A substantially modified version of the NASA-Lewis Chemical Equilibrium Code was recently developed. The modifications were designed to extend the power and convenience of the Code as a tool for performing combustor analysis for MHD systems studies. The effect of the programming details is described from a user point of view.

  2. 7 CFR 1710.205 - Minimum approval requirements for all load forecasts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... electronically to RUS computer software applications. RUS will evaluate borrower load forecasts for readability...'s engineering planning documents, such as the construction work plan, incorporate consumer and usage...

  3. 7 CFR 1710.205 - Minimum approval requirements for all load forecasts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... electronically to RUS computer software applications. RUS will evaluate borrower load forecasts for readability...'s engineering planning documents, such as the construction work plan, incorporate consumer and usage...

  4. 7 CFR 1710.205 - Minimum approval requirements for all load forecasts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... electronically to RUS computer software applications. RUS will evaluate borrower load forecasts for readability...'s engineering planning documents, such as the construction work plan, incorporate consumer and usage...

  5. Evaluation of gastroenterology and hepatology articles on Wikipedia: are they suitable as learning resources for medical students?

    PubMed

    Azer, Samy A

    2014-02-01

    With the changes introduced to medical curricula, medical students use learning resources on the Internet such as Wikipedia. However, the credibility of the medical content of Wikipedia has been questioned and there is no evidence to respond to these concerns. The aim of this paper was to critically evaluate the accuracy and reliability of the gastroenterology and hepatology information that medical students retrieve from Wikipedia. The Wikipedia website was searched for articles on gastroenterology and hepatology on 28 May 2013. Copies of these articles were evaluated by three assessors independently using an appraisal form modified from the DISCERN instrument. The articles were scored for accuracy of content, readability, frequency of updating, and quality of references. A total of 39 articles were evaluated. Although the articles appeared to be well cited and reviewed regularly, several problems were identified with regard to depth of discussion of mechanisms and pathogenesis of diseases, as well as poor elaboration on different investigations. Analysis of the content showed a score ranging from 15.6±0.6 to 43.6±3.2 (mean±SD). The total number of references in all articles was 1233, and the number of references varied from 4 to 144 (mean±SD, 31.6±27.3). The number of citations from peer-reviewed journals published in the last 5 years was 242 (28%); however, several problems were identified in the list of references and citations made. The readability of articles was in the range of -8.0±55.7 to 44.4±1.4; for all articles the readability was 26±9.0 (mean±SD). The concordance between the assessors on applying the criteria had mean κ scores in the range of 0.61 to 0.79. Wikipedia is not a reliable source of information for medical students searching for gastroenterology and hepatology articles. Several limitations, deficiencies, and scientific errors have been identified in the articles examined.

  6. Uppercase and lowercase computer printout increases readability

    NASA Technical Reports Server (NTRS)

    Hand, W. W.; Jonsberg, M. B.

    1965-01-01

    Print chain of 120 characters facilitates production of computer printout in both uppercase and lowercase characters. Although the output speed is reduced, the use of the print chain increases the computer printout readability.

  7. A text comprehension approach to questionnaire readability: An example using gambling disorder measures.

    PubMed

    Peter, Samuel C; Whelan, James P; Pfund, Rory A; Meyers, Andrew W

    2018-06-14

    Although readability has been traditionally operationalized and even become synonymous with the concept of word and sentence length, modern text analysis theory and technology have shifted toward multidimensional comprehension-based analytic techniques. In an effort to make use of these advancements and demonstrate their general utility, 6 commonly used measures of gambling disorder were submitted to readability analyses using 2 of these advanced approaches, Coh-Metrix and Question Understanding Aid (QUAID), and one traditional approach, the Flesch-Kincaid Grade Level. As hypothesized, significant variation was found across measures, with some questionnaires emerging as more appropriate than others for use in samples that may include individuals with low literacy. Recommendations are made for the use of these modern approaches to readability to inform decisions on measure selection and development. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  8. Readability of Patient Education Materials From the Web Sites of Orthopedic Implant Manufacturers.

    PubMed

    Yi, Meghan M; Yi, Paul H; Hussein, Khalil I; Cross, Michael B; Della Valle, Craig J

    2017-12-01

    Prior studies indicate that orthopedic patient education materials are written at a level that is too high for the average patient. The purpose of this study was to assess the readability of online patient education materials provided by orthopedic implant manufacturers. All patient education articles available in 2013 from the web sites of the 5 largest orthopedic implant manufacturers were identified. Each article was evaluated with the Flesch-Kincaid (FK) readability test. The number of articles with readability ≤ the eighth-grade level (average reading ability of US adults) and the sixth-grade level (recommended level for patient education materials) was determined. Mean readability levels of each company's articles were compared using analysis of variance (significance set at P < .05). A total of 581 articles were reviewed from the 5 largest implant manufacturers. The mean overall FK grade level was 10.9 (range, 3.8-16.1). Only 58 articles (10%) were written ≤ the eighth-grade level, and only 13 (2.2%) were ≤ the sixth-grade level. The mean FK grade level was significantly different among groups (Smith & Nephew = 12.0, Stryker = 11.6, Biomet = 11.3, DePuy = 10.6, Zimmer = 10.1; P < .0001). The majority of patient education materials from implant manufacturers are written at a level too high to be comprehended by the average patient. Future efforts should be made to improve the readability of orthopedic patient education materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The Readability of Online Resources for Mastopexy Surgery.

    PubMed

    Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2016-01-01

    As more patients use Internet resources for health information, there is increasing interest in evaluating the readability of available online materials. The National Institutes of Health and American Medical Association recommend that patient educational content be written at a sixth-grade reading level. This study evaluates the most popular online resources for information about mastopexy relative to average adult literacy in the United States. The 12 most popular sites returned by the largest Internet search engine were identified using the search term "breast lift surgery." Relevant articles from the main sites were downloaded and formatted into text documents. Pictures, captions, links, and references were excluded. The readability of these 100 articles was analyzed overall and subsequently by site using 10 established readability tests. Subgroup analysis was performed for articles discussing the benefits of surgery and those focusing on risks. The overall average readability of online patient information was 13.3 (range, 11.1-15). There was a range of average readability scores overall across the 12 sites from 8.9 to 16.1, suggesting that some may be more appropriate than others for patient demographics with different health literacy levels. Subgroup analysis revealed that articles discussing the risks of mastopexy were significantly harder to read (mean, 14.1) than articles about benefits (11.6). Patient-directed articles from the most popular online resources for mastopexy information are uniformly above the recommended reading level and likely too difficult to be understood by a large number of patients in the United States.

  10. Quality of websites with patient information about spinal cord injury in Spanish.

    PubMed

    Bea-Muñoz, M; Medina-Sánchez, M; Flórez-García, M T

    2016-07-01

    Descriptive, cross-sectional analysis of websites with information on spinal cord injury (SCI) in Spanish. To assess the quality, readability and presence of quality labels on web pages with information about SCI in Spanish. The Internet. An Internet search was conducted on Google with the keywords 'lesión medular' (spinal cord injury), 'paraplejia' (paraplegia) and 'tetraplejia' (tetraplegia). The first 50 results of each search were included. The quality of websites was assessed with the LIDA tool while the readability was assessed with the Flesch-Szigriszt index and the INFLESZ scale. We also checked the presence of any quality label. After excluding duplicated and irrelevant results, 33 websites were analysed. Only four of them had a quality label. The mean score of the LIDA tool was 61.12% (medium quality), and the worst results were those referring to the reliability of the information. The readability of the web pages was somewhat difficult, with a mean of 48.22 in the Flesch-Szigriszt index. Only eight of the websites showed normal readability. We observed no differences in either the quality or the readability of the websites according to their origin or the presence of quality labels. The websites analysed present a medium quality. Mainly, they should improve the reliability of their contents and their readability, including more quality labels. For SCI information in Spanish to be understandable and to provide valuable content, websites analysed in our study need to improve the quality parameters.

  11. Orthopaedic Patient Information on the World Wide Web: An Essential Review.

    PubMed

    Cassidy, John Tristan; Baker, Joseph F

    2016-02-17

    Patients increasingly use the Internet to research health-related issues. Internet content, unlike other forms of media, is not regulated. Although information accessed online can impact patients' opinions and expectations, there is limited information about the quality or readability of online orthopaedic information. PubMed, MEDLINE, and Google Scholar were searched using anatomic descriptors and three title keywords ("Internet," "web," and "online"). Articles examining online orthopaedic information from January 1, 2000, until April 1, 2015, were recorded. Articles were assessed for the number of reviewers evaluating the online material, whether the article examined for a link between authorship and quality, and the use of recognized quality and readability assessment tools. To facilitate a contemporary discussion, only publications since January 1, 2010, were considered for analysis. A total of thirty-eight peer-reviewed articles published since 2010 examining the quality and/or readability of online orthopaedic information were reviewed. For information quality, there was marked variation in the quality assessment methods utilized, the number of reviewers, and the manner of reporting. To date, the majority of examined information is of poor quality. Studies examining readability have focused on pages produced by professional orthopaedic societies. The quality and readability of online orthopaedic information are generally poor. For modern practices to adapt to the Internet and to prevent misinformation, the orthopaedic community should develop high-quality, readable online patient information. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Readability assessment of internet-based patient education materials related to facial fractures.

    PubMed

    Sanghvi, Saurin; Cherla, Deepa V; Shukla, Pratik A; Eloy, Jean Anderson

    2012-09-01

    Various professional societies, clinical practices, hospitals, and health care-related Web sites provide Internet-based patient education material (IPEMs) to the general public. However, this information may be written above the 6th-grade reading level recommended by the US Department of Health and Human Services. The purpose of this study is to assess the readability of facial fracture (FF)-related IPEMs and compare readability levels of IPEMs provided by four sources: professional societies, clinical practices, hospitals, and miscellaneous sources. Analysis of IPEMs on FFs available on Google.com. The readability of 41 FF-related IPEMs was assessed with four readability indices: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG). Averages were evaluated against national recommendations and between each source using analysis of variance and t tests. Only 4.9% of IPEMs were written at or below the 6th-grade reading level, based on FKGL. The mean readability scores were: FRES 54.10, FKGL 9.89, SMOG 12.73, and Gunning FOG 12.98, translating into FF-related IPEMs being written at a "difficult" writing level, which is above the level of reading understanding of the average American adult. IPEMs related to FFs are written above the recommended 6th-grade reading level. Consequently, this information would be difficult to understand by the average US patient. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  13. An evaluation of the readability of drinking water quality reports: a national assessment.

    PubMed

    Roy, Siddhartha; Phetxumphou, Katherine; Dietrich, Andrea M; Estabrooks, Paul A; You, Wen; Davy, Brenda M

    2015-09-01

    The United States Environmental Protection Agency mandates that community water systems (or water utilities) provide annual consumer confidence reports (CCRs)--water quality reports--to their consumers. These reports encapsulate information regarding sources of water, detected contaminants, regulatory compliance, and educational material. These reports have excellent potential for providing the public with accurate information on the safety of tap water, but there is a lack of research on the degree to which the information can be understood by a large proportion of the population. This study evaluated the readability of a nationally representative sample of 30 CCRs, released between 2011 and 2013. Readability (or 'comprehension difficulty') was evaluated using Flesch-Kincaid readability tests. The analysis revealed that CCRs were written at the 11th-14th grade level, which is well above the recommended 6th-7th grade level for public health communications. The CCR readability ease was found to be equivalent to that of the Harvard Law Review journal. These findings expose a wide chasm that exists between current water quality reports and their effectiveness toward being understandable to US residents. Suggestions for reorienting language and scientific information in CCRs to be easily comprehensible to the public are offered.

  14. Micro PAVER, Version 1.0, User’s Guide, Airport Pavement Management System,

    DTIC Science & Technology

    1986-10-01

    repair data have been entered for the policy, the following prompts will appear on your screen. Policy Numbr:I Policy Description: PRIMA Y UNW AYS ND... Materia ’ Codes (those material codes entered by the Micro PAVER developers) can not be modified or deleted. New material codes can be added, modified, or

  15. Doing It Right: 366 answers to computing questions you didn't know you had

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herring, Stuart Davis

    Slides include information on history: version control, version control: branches, version control: Git, releases, requirements, readability, readability control flow, global variables, architecture, architecture redundancy, processes, input/output, unix, etcetera.

  16. A Practical Note on Readability Formulas

    ERIC Educational Resources Information Center

    Pauk, Walter

    1969-01-01

    Compares the readability formulas devised by Fry and McLaughlin to the Dale-Chall formula and reports similar results with the Fry and Dale-Chall formulas, but variant results using the McLaughlin formula. Bibliography. (MD)

  17. A survey of machine readable data bases

    NASA Technical Reports Server (NTRS)

    Matlock, P.

    1981-01-01

    Forty-two of the machine readable data bases available to the technologist and researcher in the natural sciences and engineering are described and compared with the data bases and date base services offered by NASA.

  18. A Synthesis of Research on Color, Typography, and Graphics as they Relate to Readability.

    DTIC Science & Technology

    1985-09-01

    READABILITY THESIS Melvin E. Lamoreaux Captain, USAF ________AF IT/GLM/LSH/85S-40 ___- D T~DTIC ELECTE NOV 2 1 85 DEPARTMENT OF THE AIR FORCE E AIR...UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio I Thi document hA= been p d i hP rel alse .,,ci I ,. 11 10 108...definitions of readability. For example, E. D . Hirsch, Jr., defines ;" adabiflty by the time and effort needed when, *assuming ... two texts convey the

  19. The readability of scientific texts is decreasing over time

    PubMed Central

    2017-01-01

    Clarity and accuracy of reporting are fundamental to the scientific process. Readability formulas can estimate how difficult a text is to read. Here, in a corpus consisting of 709,577 abstracts published between 1881 and 2015 from 123 scientific journals, we show that the readability of science is steadily decreasing. Our analyses show that this trend is indicative of a growing use of general scientific jargon. These results are concerning for scientists and for the wider public, as they impact both the reproducibility and accessibility of research findings. PMID:28873054

  20. The critical evaluation of stellar data

    NASA Technical Reports Server (NTRS)

    Underhill, A. B.; Mead, J. M.; Nagy, T. A.

    1977-01-01

    The paper discusses the importance of evaluating a catalog of stellar data, whether it is an old catalog being made available in machine-readable form, or a new catalog written expressly in machine-readable form, and discusses some principles to be followed in the evaluation of such data. A procedure to be followed when checking out an astronomical catalog on magnetic tape is described. A cross index system which relates the different identification numbers of a star or other astronomical object as they appear in different catalogs in machine-readable form is described.

  1. Readability of informed consent forms in clinical trials conducted in a skin research center

    PubMed Central

    Samadi, Aniseh; Asghari, Fariba

    2016-01-01

    Obtaining informed consents is one of the most fundamental principles in conducting a clinical trial. In order for the consent to be informed, the patient must receive and comprehend the information appropriately. Complexity of the consent form is a common problem that has been shown to be a major barrier to comprehension for many patients. The objective of this study was to assess the readability of different templates of informed consent forms (ICFs) used in clinical trials in the Center for Research and Training in Skin Diseases and Leprosy (CRTSDL), Tehran, Iran. This study was conducted on ICFs of 45 clinical trials of the CRTSDL affiliated with Tehran University of Medical Sciences. ICFs were tested for reading difficulty, using the readability assessments formula adjusted for the Persian language including the Flesch–Kincaid reading ease score, Flesch–Kincaid grade level, and Gunning fog index. Mean readability score of the whole text of ICFs as well as their 7 main information parts were calculated. The mean ± SD Flesch Reading Ease score for all ICFs was 31.96 ± 5.62 that is in the difficult range. The mean ± SD grade level was calculated as 10.71 ± 1.8 (8.23–14.09) using the Flesch–Kincaid formula and 14.64 ± 1.22 (12.67–18.27) using the Gunning fog index. These results indicate that the text is expected to be understandable for an average student in the 11th grade, while the ethics committee recommend grade level 8 as the standard readability level for ICFs. The results showed that the readability scores of ICFs assessed in our study were not in the acceptable range. This means they were too complex to be understood by the general population. Ethics committees must examine the simplicity and readability of ICFs used in clinical trials. PMID:27471590

  2. Online Health Information Regarding Male Infertility: An Evaluation of Readability, Suitability, and Quality.

    PubMed

    Robins, Stephanie; Barr, Helena J; Idelson, Rachel; Lambert, Sylvie; Zelkowitz, Phyllis

    2016-10-21

    Many men lack knowledge about male infertility, and this may have consequences for their reproductive and general health. Men may prefer to seek health information online, but these sources of information vary in quality. The objective of this study is to determine if online sources of information regarding male infertility are readable, suitable, and of appropriate quality for Internet users in the general population. This study used a cross-sectional design to evaluate online sources resulting from search engine queries. The following categories of websites were considered: (1) Canadian fertility clinics, (2) North American organizations related to fertility, and (3) the first 20 results of Google searches using the terms "male infertility" and "male fertility preservation" set to the search locations worldwide, English Canada, and French Canada. Websites that met inclusion criteria (N=85) were assessed using readability indices, the Suitability Assessment of Materials (SAM), and the DISCERN tool. The associations between website affiliation (government, university/medical, non-profit organization, commercial/corporate, private practice) and Google placement to readability, suitability, and quality were also examined. None of the sampled websites met recommended levels of readability. Across all websites, the mean SAM score for suitability was 45.37% (SD 11.21), or "adequate", while the DISCERN mean score for quality was 43.19 (SD 10.46) or "fair". Websites that placed higher in Google obtained a higher overall score for quality with an r (58) value of -.328 and a P value of .012, but this position was not related to readability or suitability. In addition, 20% of fertility clinic websites did not include fertility information for men. There is a lack of high quality online sources of information on male fertility. Many websites target their information to women, or fail to meet established readability criteria for the general population. Since men may prefer to seek health information online, it is important that health care professionals develop high quality sources of information on male fertility for the general population.

  3. The effect of search term on the quality and accuracy of online information regarding distal radius fractures.

    PubMed

    Dy, Christopher J; Taylor, Samuel A; Patel, Ronak M; Kitay, Alison; Roberts, Timothy R; Daluiski, Aaron

    2012-09-01

    Recent emphasis on shared decision making and patient-centered research has increased the importance of patient education and health literacy. The internet is rapidly growing as a source of self-education for patients. However, concern exists over the quality, accuracy, and readability of the information. Our objective was to determine whether the quality, accuracy, and readability of information online about distal radius fractures vary with the search term. This was a prospective evaluation of 3 search engines using 3 different search terms of varying sophistication ("distal radius fracture," "wrist fracture," and "broken wrist"). We evaluated 70 unique Web sites for quality, accuracy, and readability. We used comparative statistics to determine whether the search term affected the quality, accuracy, and readability of the Web sites found. Three orthopedic surgeons independently gauged quality and accuracy of information using a set of predetermined scoring criteria. We evaluated the readability of the Web site using the Fleisch-Kincaid score for reading grade level. There were significant differences in the quality, accuracy, and readability of information found, depending on the search term. We found higher quality and accuracy resulted from the search term "distal radius fracture," particularly compared with Web sites resulting from the term "broken wrist." The reading level was higher than recommended in 65 of the 70 Web sites and was significantly higher when searching with "distal radius fracture" than "wrist fracture" or "broken wrist." There was no correlation between Web site reading level and quality or accuracy. The readability of information about distal radius fractures in most Web sites was higher than the recommended reading level for the general public. The quality and accuracy of the information found significantly varied with the sophistication of the search term used. Physicians, professional societies, and search engines should consider efforts to improve internet access to high-quality information at an understandable level. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Initial Readability Assessment of Clinical Trial Eligibility Criteria

    PubMed Central

    Kang, Tian; Elhadad, Noémie; Weng, Chunhua

    2015-01-01

    Various search engines are available to clinical trial seekers. However, it remains unknown how comprehensible clinical trial eligibility criteria used for recruitment are to a lay audience. This study initially investigated this problem. Readability of eligibility criteria was assessed according to (i) shallow and lexical characteristics through the use of an established, generic readability metric; (ii) syntactic characteristics through natural language processing techniques; and (iii) health terminological characteristics through an automated comparison to technical and lay health texts. We further stratified clinical trials according to various study characteristics (e.g., source country or study type) to understand potential factors influencing readability. Mainly caused by frequent use of technical jargons, a college reading level was found to be necessary to understand eligibility criteria text, a level much higher than the average literacy level of the general American population. The use of technical jargons should be minimized to simplify eligibility criteria text. PMID:26958204

  5. The readability and suitability of sexual health promotion leaflets.

    PubMed

    Corcoran, Nova; Ahmad, Fatuma

    2016-02-01

    To investigate the readability and suitability of sexual health promotion leaflets. Application of SMOG, FRY and SAM tests to assess the readability and suitability of a selection of sexual health leaflets. SMOG and FRY scores illustrate an average reading level of grade 9. SAM scores indicate that 59% of leaflets are superior in design and 41% are average in design. Leaflets generally perform well in the categories of content, literacy demand, typography and layout. They perform poorly in use of graphics, learning stimulation/motivation and cultural appropriateness. Sexual health leaflets have a reading level that is too high. Leaflets perform well on the suitability scores indicating they are reasonably suitable. There are a number of areas where sexual health leaflets could improve their design. Numerous practical techniques are suggested for improving the readability and suitability of sexual health leaflets. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of the Quality, Accuracy, and Readability of Online Patient Resources for the Management of Articular Cartilage Defects.

    PubMed

    Wang, Dean; Jayakar, Rohit G; Leong, Natalie L; Leathers, Michael P; Williams, Riley J; Jones, Kristofer J

    2017-04-01

    Objective Patients commonly use the Internet to obtain their health-related information. The purpose of this study was to investigate the quality, accuracy, and readability of online patient resources for the management of articular cartilage defects. Design Three search terms ("cartilage defect," "cartilage damage," "cartilage injury") were entered into 3 Internet search engines (Google, Bing, Yahoo). The first 25 websites from each search were collected and reviewed. The quality and accuracy of online information were independently evaluated by 3 reviewers using predetermined scoring criteria. The readability was evaluated using the Flesch-Kincaid (FK) grade score. Results Fifty-three unique websites were evaluated. Quality ratings were significantly higher in websites with a FK score >11 compared to those with a score of ≤11 ( P = 0.021). Only 10 websites (19%) differentiated between focal cartilage defects and diffuse osteoarthritis. Of these, 7 (70%) were elicited using the search term "cartilage defect" ( P = 0.038). The average accuracy of the websites was high (11.7 out of maximum 12), and the average FK grade level (13.4) was several grades higher than the recommended level for readable patient education material (eighth grade level). Conclusions The quality and readability of online patient resources for articular cartilage defects favor those with a higher level of education. Additionally, the majority of these websites do not distinguish between focal chondral defects and diffuse osteoarthritis, which can fail to provide appropriate patient education and guidance for available treatment. Clinicians should help guide patients toward high-quality, accurate, and readable online patient education material.

  7. Analysis of the readability of patient education materials from surgical subspecialties.

    PubMed

    Hansberry, David R; Agarwal, Nitin; Shah, Ravi; Schmitt, Paul J; Baredes, Soly; Setzen, Michael; Carmel, Peter W; Prestigiacomo, Charles J; Liu, James K; Eloy, Jean Anderson

    2014-02-01

    Patients are increasingly using the Internet as a source of information on medical conditions. Because the average American adult reads at a 7th- to 8th-grade level, the National Institutes of Health recommend that patient education material be written between a 4th- and 6th-grade level. In this study, we assess and compare the readability of patient education materials on major surgical subspecialty Web sites relative to otolaryngology. Descriptive and correlational design. Patient education materials from 14 major surgical subspecialty Web sites (American Society of Colon and Rectal Surgeons, American Association of Endocrine Surgeons, American Society of General Surgeons, American Society for Metabolic and Bariatric Surgery, American Association of Neurological Surgeons, American Congress of Obstetricians and Gynecologists, American Academy of Ophthalmology, American Academy of Orthopedic Surgeons, American Academy of Otolaryngology-Head and Neck Surgery, American Pediatric Surgical Association, American Society of Plastic Surgeons, Society for Thoracic Surgeons, and American Urological Association) were downloaded and assessed for their level of readability using 10 widely accepted readability scales. The readability level of patient education material from all surgical subspecialties was uniformly too high. Average readability levels across all subspecialties ranged from the 10th- to 15th-grade level. Otolaryngology and other surgical subspecialties Web sites have patient education material written at an education level that the average American may not be able to understand. To reach a broader population of patients, it might be necessary to rewrite patient education material at a more appropriate level. N/A. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Readability Assessment of Online Patient Abdominoplasty Resources.

    PubMed

    Phillips, Nicole A; Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2015-02-01

    Limited functional health literacy is recognized as an important contributor to health disparities in the United States. As internet access becomes more universal, there is increasing concern about whether patients with poor or marginal literacy can access understandable healthcare information. As such, the National Institutes of Health and American Medical Association recommend that patient information be written at a sixth grade level. This study identifies the most popular online resources for patient information about abdominoplasty and evaluates their readability in the context of average American literacy. The two largest internet search engines were queried for "tummy tuck surgery" to simulate a patient search in lay terms. The ten most popular sites common to both search engines were identified, and all relevant articles from the main sites were downloaded. Sponsored results were excluded. Readability analysis of the articles was performed using ten established tests. Online information about abdominoplasty from the ten most popular publically available websites had an overall average readability of 12th grade. Mean reading grade level scores among tests were: Coleman-Liau 11.9, Flesch-Kincaid 11.4, FORCAST 11.1, Fry 13, Gunning Fog 13.5, New Dale-Chall 11.8, New Fog Count 9.9, Raygor Estimate 12, and SMOG 13.4; Flesch Reading Ease index score was 46. Online patient resources about abdominoplasty are uniformly above the recommended target readability level and are likely too difficult for many patients to understand. A range of readability identified among websites could allow surgeons to guide patients to more appropriate resources for their literacy skills.

  9. Readability analysis of online resources related to lung cancer.

    PubMed

    Weiss, Kathleen D; Vargas, Christina R; Ho, Olivia A; Chuang, Danielle J; Weiss, Jonathan; Lee, Bernard T

    2016-11-01

    Patients seeking health information commonly use the Internet as the first source for material. Studies show that well-informed patients have increased involvement, satisfaction, and healthcare outcomes. As one-third of Americans have only basic or below basic health literacy, the National Institutes of Health and American Medical Association recommend patient-directed health resources be written at a sixth-grade reading level. This study evaluates the readability of commonly accessed online resources on lung cancer. A search for "lung cancer" was performed using Google and Bing, and the top 10 websites were identified. Location services were disabled, and sponsored sites were excluded. Relevant articles (n = 109) with patient-directed content available directly from the main sites were downloaded. Readability was assessed using 10 established methods and analyzed with articles grouped by parent website. The average reading grade level across all sites was 11.2, with a range from 8.8 (New Fog Count) to 12.2 (Simple Measure of Gobbledygook). The average Flesch Reading Ease score was 52, corresponding with fairly difficult to read text. The readability varied when compared by individual website, ranging in grade level from 9.2 to 15.2. Only 10 articles (9%) were written below a sixth-grade level and these tended to discuss simpler topics. Patient-directed online information about lung cancer exceeds the recommended sixth-grade reading level. Readability varies between individual websites, allowing physicians to direct patients according to level of health literacy. Modifications to existing materials can significantly improve readability while maintaining content for patients with low health literacy. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Content, format, gender and grade level differences in elementary students' ability to read science materials as measured by the cloze procedure

    NASA Astrophysics Data System (ADS)

    Williams, Richard L.; Yore, Larry D.

    Present instructional trends in science indicate a need to reexamine a traditional concern in science education: the readability of science textbooks. An area of reading research not well documented is the effect of color, visuals, and page layout on readability of science materials. Using the cloze readability method, the present study explored the relationships between page format, grade level, sex, content, and elementary school students ability to read science material. Significant relationships were found between cloze scores and both grade level and content, and there was a significant interaction effect between grade and sex in favor of older males. No significant relationships could be attributed to page format and sex. In the area of science content, biological materials were most difficult in terms of readability followed by earth science and physical science. Grade level data indicated that grade five materials were more difficult for that level than either grade four or grade six materials were for students at each respective level. In eight of nine cases, the science text materials would be classified at or near the frustration level of readability. The implications for textbook writers and publishers are that science reading materials need to be produced with greater attention to readability and known design principles regarding visual supplements. The implication for teachers is that students need direct instruction in using visual materials to increase their learning from text material. Present visual materials appear to neither help nor hinder the student to gain information from text material.

  11. Readability Trends of Online Information by the American Academy of Otolaryngology-Head and Neck Surgery Foundation.

    PubMed

    Wong, Kevin; Levi, Jessica R

    2017-01-01

    Objective Previous studies have shown that patient education materials published by the American Academy of Otolaryngology-Head and Neck Surgery Foundation may be too difficult for the average reader to understand. The purpose of this study was to determine if current educational materials show improvements in readability. Study Design Cross-sectional analysis. Setting The Patient Health Information section of the American Academy of Otolaryngology-Head and Neck Surgery Foundation website. Subjects and Methods All patient education articles were extracted in plain text. Webpage navigation, references, author information, appointment information, acknowledgments, and disclaimers were removed. Follow-up editing was also performed to remove paragraph breaks, colons, semicolons, numbers, percentages, and bullets. Readability grade was calculated with the Flesch-Kincaid Grade Level, Flesch Reading Ease, Gunning-Fog Index, Coleman-Liau Index, Automated Readability Index, and Simple Measure of Gobbledygook. Intra- and interobserver reliability were assessed. Results A total of 126 articles from 7 topics were analyzed. Readability levels across all 6 tools showed that the difficulty of patient education materials exceeded the abilities of an average American. As compared with previous studies, current educational materials by the American Academy of Otolaryngology-Head and Neck Surgery Foundation have shown a decrease in difficulty. Intra- and interobserver reliability were both excellent, with intraclass coefficients of 0.99 and 0.96, respectively. Conclusion Improvements in readability is an encouraging finding and one that is consistent with recent trends toward improved health literacy. Nevertheless, online patient educational material is still too difficult for the average reader. Revisions may be necessary for current materials to benefit a larger readership.

  12. Readability and quality of wikipedia pages on neurosurgical topics.

    PubMed

    Modiri, Omeed; Guha, Daipayan; Alotaibi, Naif M; Ibrahim, George M; Lipsman, Nir; Fallah, Aria

    2018-03-01

    Wikipedia is the largest online encyclopedia with over 40 million articles, and generating 500 million visits per month. The aim of this study is to assess the readability and quality of Wikipedia pages on neurosurgical related topics. We selected the neurosurgical related Wikipedia pages based on the series of online patient information articles that are published by the American Association of Neurological Surgeons (AANS). We assessed readability of Wikipedia pages using five different readability scales (Flesch Reading Ease, Flesch Kincaid Grade Level, Gunning Fog Index, SMOG) Grade level, and Coleman-Liau Index). We used the Center for Disease Control (CDC) Clear Communication Index as well as the DISCERN Instrument to evaluate the quality of each Wikipedia article. We identified a total of fifty-five Wikipedia articles that corresponded with patient information articles published by the AANS. This constitutes 77.46% of the AANS topics. The mean Flesch Kincaid reading ease score for all of the Wikipedia articles we analyzed is 31.10, which indicates that a college-level education is necessary to understand them. In comparison to the readability analysis for the AANS articles, the Wikipedia articles were more difficult to read across every scale. None of the Wikipedia articles meet the CDC criterion for clear communications. Our analyses demonstrated that Wikipedia articles related to neurosurgical topics are associated with higher grade levels for reading and also below the expected levels of clear communications for patients. Collaborative efforts from the neurosurgical community are needed to enhance the readability and quality of Wikipedia pages related to neurosurgery. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. What parents are reading about laryngomalacia: Quality and readability of internet resources on laryngomalacia.

    PubMed

    Corredera, Erica; Davis, Kara S; Simons, Jeffrey P; Jabbour, Noel

    2018-05-01

    The goal of this study is to measure the quality and readability of websites related to laryngomalacia, and to compare the quality and readability scores for the sites accessed through the most popular search engines. Laryngomalacia is a common diagnosis in children but is often difficult for parents to comprehend. As information available on the internet is unregulated, the quality and readability of this information may vary. An advanced search on Google, Yahoo, and Bing was conducted using the terms "laryngomalacia" OR "soft larynx" OR "floppy voice box." The first ten websites meeting inclusion and exclusion criteria were evaluated, for each search engine. Quality and readability were assessed using the DISCERN criteria and the Flesch reading ease scoring (FRES) and Flesch-Kincaid grade level (FKGL) tests, respectively. The top 10 hits on each search engine yielded 15 unique web pages. The median DISCERN score (out of a possible high-score of 80) was 48.5 (SD 12.6). The median USA grade-level estimated by the FKGL was 11.3 (SD 1.4). Only one website (6.7%), had a readability score in the optimal range of 6th to 8th grade reading level. DISCERN scores did not correlate with FKGL scores (r = 0.10). Online information discussing laryngomalacia often varies in quality and may not be easily comprehensible to the public. It is important for healthcare professionals to understand the quality of health information accessible to patients as it may influence medical decision-making by patient families. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Readability of internet-sourced patient education material related to "labour analgesia".

    PubMed

    Boztas, Nilay; Omur, Dilek; Ozbılgın, Sule; Altuntas, Gözde; Piskin, Ersan; Ozkardesler, Sevda; Hanci, Volkan

    2017-11-01

    We evaluated the readability of Internet-sourced patient education materials (PEMs) related to "labour analgesia." In addition to assessing the readability of websites, we aimed to compare commercial, personal, and academic websites.We used the most popular search engine (http://www.google.com) in our study. The first 100 websites in English that resulted from a search for the key words "labour analgesia" were scanned. Websites that were not in English, graphs, pictures, videos, tables, figures and list formats in the text, all punctuation, the number of words in the text is less than 100 words, feedback forms not related to education, (Uniform Resource Locator) URL websites, author information, references, legal disclaimers, and addresses and telephone numbers were excluded.The texts included in the study were assessed using the Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (FOG) readability formulae. The number of Latin words within the text was determined.Analysis of 300-word sections of the texts revealed that the mean FRES was 47.54 ± 12.54 (quite difficult), mean FKGL and SMOG were 11.92 ± 2.59 and 10.57 ± 1.88 years of education, respectively, and mean Gunning FOG was 14.71 ± 2.76 (very difficult). Within 300-word sections, the mean number of Latin words was identified as 16.56 ± 6.37.In our study, the readability level of Internet-sourced PEM related to "labour analgesia" was identified to be quite high indicating poor readability.

  15. The quality of websites addressing fibromyalgia: an assessment of quality and readability using standardised tools

    PubMed Central

    MacDermid, Joy C; Wilkins, Seanne; Gibson, Jane; Shaw, Lynn

    2011-01-01

    Background Patients living with fibromyalgia strongly prefer to access health information on the web. However, the majority of subjects in previous studies strongly expressed their concerns about the quality of online information resources. Objectives The purpose of this study was to evaluate existing online fibromyalgia information resources for content, quality and readability by using standardised quality and readability tools. Methods The first 25 websites were identified using Google and the search keyword ‘fibromyalgia’. Pairs of raters independently evaluated website quality using two structured tools (DISCERN and a quality checklist). Readability was assessed using the Flesch Reading Ease score maps. Results Ranking of the websites' quality varied by the tool used, although there was general agreement about the top three websites (Fibromyalgia Information, Fibromyalgia Information Foundation and National Institute of Arthritis and Musculoskeletal and Skin Diseases). Content analysis indicated that 72% of websites provided information on treatment options, 68% on symptoms, 60% on diagnosis and 40% on coping and resources. DISCERN ratings classified 32% websites as ‘very good’, 32% as ‘good and 36% as ‘marginal’. The mean overall DISCERN score was 36.88 (good). Only 16% of websites met the recommended literacy level grade of 6–8 (range 7–15). Conclusion Higher quality websites tended to be less readable. Online fibromyalgia information resources do not provide comprehensive information about fibromyalgia, and have low quality and poor readability. While information is very important for those living with fibromyalgia, current resources are unlikely to provide necessary or accurate information, and may not be usable for most people. PMID:22021777

  16. The quality of websites addressing fibromyalgia: an assessment of quality and readability using standardised tools.

    PubMed

    Daraz, Lubna; Macdermid, Joy C; Wilkins, Seanne; Gibson, Jane; Shaw, Lynn

    2011-07-31

    Background Patients living with fibromyalgia strongly prefer to access health information on the web. However, the majority of subjects in previous studies strongly expressed their concerns about the quality of online information resources. Objectives The purpose of this study was to evaluate existing online fibromyalgia information resources for content, quality and readability by using standardised quality and readability tools. Methods The first 25 websites were identified using Google and the search keyword 'fibromyalgia'. Pairs of raters independently evaluated website quality using two structured tools (DISCERN and a quality checklist). Readability was assessed using the Flesch Reading Ease score maps. Results Ranking of the websites' quality varied by the tool used, although there was general agreement about the top three websites (Fibromyalgia Information, Fibromyalgia Information Foundation and National Institute of Arthritis and Musculoskeletal and Skin Diseases). Content analysis indicated that 72% of websites provided information on treatment options, 68% on symptoms, 60% on diagnosis and 40% on coping and resources. DISCERN ratings classified 32% websites as 'very good', 32% as 'good and 36% as 'marginal'. The mean overall DISCERN score was 36.88 (good). Only 16% of websites met the recommended literacy level grade of 6-8 (range 7-15). Conclusion Higher quality websites tended to be less readable. Online fibromyalgia information resources do not provide comprehensive information about fibromyalgia, and have low quality and poor readability. While information is very important for those living with fibromyalgia, current resources are unlikely to provide necessary or accurate information, and may not be usable for most people.

  17. How well are health information websites displayed on mobile phones? Implications for the readability of health information.

    PubMed

    Cheng, Christina; Dunn, Matthew

    2017-03-01

    Issue addressed More than 87% of Australians own a mobile phone with Internet access and 82% of phone owners use their smartphones to search for health information, indicating that mobile phones may be a powerful tool for building health literacy. Yet, online health information has been found to be above the reading ability of the general population. As reading on a smaller screen may further complicate the readability of information, this study aimed to examine how health information is displayed on mobile phones and its implications for readability. Methods Using a cross-sectional design with convenience sampling, a sample of 270 mobile webpages with information on 12 common health conditions was generated for analysis, they were categorised based on design and position of information display. Results The results showed that 71.48% of webpages were mobile-friendly but only 15.93% were mobile-friendly webpages designed in a way to optimise readability, with a paging format and queried information displayed for immediate viewing. Conclusion With inadequate evidence and lack of consensus on how webpage design can best promote reading and comprehension, it is difficult to draw a conclusion on the effect of current mobile health information presentation on readability. So what? Building mobile-responsive websites should be a priority for health information providers and policy-makers. Research efforts are urgently required to identify how best to enhance readability of mobile health information and fully capture the capabilities of mobile phones as a useful device to increase health literacy.

  18. Readability Formulas as Applied to College Economics Textbooks.

    ERIC Educational Resources Information Center

    McConnell, Campbell R.

    1982-01-01

    Determines from empirical information on the application of four readability formulas to a group of widely used college economics textbooks that there is no consistency in the absolute reading levels or the rank orderings of these books. (AEA)

  19. An Empirical Test of the Modified C Index and SII, O*NET, and DHOC Occupational Code Classifications

    ERIC Educational Resources Information Center

    Dik, Bryan J.; Hu, Ryan S. C.; Hansen, Jo-Ida C.

    2007-01-01

    The present study investigated new approaches for assessing Holland's congruence hypothesis by (a) developing and applying four sets of decision rules for assigning Holland codes of varying lengths for purposes of computing Eggerth and Andrew's modified C index; (b) testing the modified C index computed using these four approaches against Brown…

  20. Documentation for the machine-readable version of A Finding List of Stars of Spectral Type F2 and Earlier in a North Galactic Pole Region

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1982-01-01

    The machine-readable data set is the result of an objective-prism survey made with an 80 cm/120 cm Schmidt telescope. The F2 and earlier stars were isolated from later type objects by using the MK classification criteria. The catalog contains 601 stars and includes cross identifications to the BD and HD catalogs, coordinates, photographic magnitudes and spectral types. A separate file contains the remarks from the original data tables merged with those following the data. The machine-readable files are described.

  1. Readability of menopause web sites: a cross-sectional study.

    PubMed

    Charbonneau, Deborah H

    2012-01-01

    More women are frequently referring to the Internet for health information, yet the readability of information about menopause on the Internet has not been widely studied. To address this gap, this study examined the readability of information about menopause on 25 Internet Web sites. Findings included that information on the Web sites had a reading level higher than the recommended sixth-grade level, and culturally appropriate health information was lacking. Health educators and practitioners are in a pivotal role to help women understand information useful for healthcare decisions. Several criteria are discussed to help practitioners evaluate Web sites.

  2. Health literacy and the Internet: a study on the readability of Australian online health information.

    PubMed

    Cheng, Christina; Dunn, Matthew

    2015-08-01

    Almost 80% of Australian Internet users seek out health information online so the readability of this information is important. This study aimed to evaluate the readability of Australian online health information and determine if it matches the average reading level of Australians. Two hundred and fifty-one web pages with information on 12 common health conditions were identified across sectors. Readability was assessed by the Flesch-Kincaid (F-K), Simple Measure of Gobbledygook (SMOG) and Flesch Reading Ease (FRE) formulas, with grade 8 adopted as the average Australian reading level. The average reading grade measured by F-K and SMOG was 10.54 and 12.12 respectively. The mean FRE was 47.54, a 'difficult-to-read' score. Only 0.4% of web pages were written at or below grade 8 according to SMOG. Information on dementia was the most difficult to read overall, while obesity was the most difficult among government websites. The findings suggest that the readability of Australian health websites is above the average Australian levels of reading. A quantifiable guideline is needed to ensure online health information accommodates the reading needs of the general public to effectively use the Internet as an enabler of health literacy. © 2015 Public Health Association of Australia.

  3. Reading apps for children: Readability from the design perspective

    NASA Astrophysics Data System (ADS)

    Mohammed, Wasan Abdulwahab; Husni, Husniza

    2017-10-01

    Electronic reading for young children opens new avenues especially with the advance of modern reading devices. The readability of mobile learning applications has received extensive attention by the designers and developers. The reason for such concern is due to its importance in determining usability related issues especially in the design context for children. In many cases, children find it difficult to interact with mobile reading apps. This is because apps for reading and for entertainment require different features. As such, this study sets out three objectives: 1) to evaluate five reading apps for young children from design perspectives; 2) to examine the readability for current existing mobile apps for reading and 3) to propose and evaluate mobile apps UI guideline for readability. Readability indices, observation and interview were conducted on 6 - 8 years old students. The obtained result showed that certain reading apps provide better reading experience for children than others. Some of the reasons are mostly related to the design characteristics embedded within the app. In addition, the use of animation was found to stimulate children reading experience as it is believed to offer the interactivity elements to gain their interest and willingness to read. These findings are believed to provide the recommendations and insights for designers of reading apps for children.

  4. Assessing the content, presentation, and readability of dental informed consents.

    PubMed

    Glick, Aaron; Taylor, David; Valenza, John A; Walji, Muhammad F

    2010-08-01

    Informed consents are important aids in helping patients make optimal decisions. Little knowledge exists about the quality of dental informed consents. Fifty-two informed consents used throughout the University of Texas Health Science Center at Houston Dental Branch were evaluated based on the quality of their content, readability, and presentation. Content quality was judged on four basic elements: description of procedure, risk, benefits, and alternatives. Of the clinical consents, 26 percent of forms contained all four of the basic content elements, 48 percent contained three of four elements, 16 percent contained two of four elements, and 10 percent contained one of four elements. Presentation quality was judged on twelve criteria items. The average clinical consent included seven out of twelve presentation items, and the average nonclinical consent included eight out of twelve items. Readability was judged using three standard instruments for rating readability: Flesch Reading Ease, Flesch-Kincaid Grade-Level, and Simple Measure of Gobbledygook (SMOG) grading. Average Flesch-Kincaid Grade-Level was 12.7 (range, 7.4 to 19.1), significantly higher than the recommended ninth grade level (p<.001). The results suggest that many existing dental informed consents may be improved by 1) increasing the comprehensiveness of the content, 2) improving the design and layout, and 3) reducing the readability levels for patient comprehension.

  5. Designing stellarator coils by a modified Newton method using FOCUS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Caoxiang; Hudson, Stuart R.; Song, Yuntao

    To find the optimal coils for stellarators, nonlinear optimization algorithms are applied in existing coil design codes. However, none of these codes have used the information from the second-order derivatives. In this paper, we present a modified Newton method in the recently developed code FOCUS. The Hessian matrix is calculated with analytically derived equations. Its inverse is approximated by a modified Cholesky factorization and applied in the iterative scheme of a classical Newton method. Using this method, FOCUS is able to recover the W7-X modular coils starting from a simple initial guess. Results demonstrate significant advantages.

  6. Designing stellarator coils by a modified Newton method using FOCUS

    NASA Astrophysics Data System (ADS)

    Zhu, Caoxiang; Hudson, Stuart R.; Song, Yuntao; Wan, Yuanxi

    2018-06-01

    To find the optimal coils for stellarators, nonlinear optimization algorithms are applied in existing coil design codes. However, none of these codes have used the information from the second-order derivatives. In this paper, we present a modified Newton method in the recently developed code FOCUS. The Hessian matrix is calculated with analytically derived equations. Its inverse is approximated by a modified Cholesky factorization and applied in the iterative scheme of a classical Newton method. Using this method, FOCUS is able to recover the W7-X modular coils starting from a simple initial guess. Results demonstrate significant advantages.

  7. Designing stellarator coils by a modified Newton method using FOCUS

    DOE PAGES

    Zhu, Caoxiang; Hudson, Stuart R.; Song, Yuntao; ...

    2018-03-22

    To find the optimal coils for stellarators, nonlinear optimization algorithms are applied in existing coil design codes. However, none of these codes have used the information from the second-order derivatives. In this paper, we present a modified Newton method in the recently developed code FOCUS. The Hessian matrix is calculated with analytically derived equations. Its inverse is approximated by a modified Cholesky factorization and applied in the iterative scheme of a classical Newton method. Using this method, FOCUS is able to recover the W7-X modular coils starting from a simple initial guess. Results demonstrate significant advantages.

  8. PCR-free quantitative detection of genetically modified organism from raw materials. An electrochemiluminescence-based bio bar code method.

    PubMed

    Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R

    2008-05-15

    A bio bar code assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio bar code assay requires lengthy experimental procedures including the preparation and release of bar code DNA probes from the target-nanoparticle complex and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio bar code assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2,2'-bipyridyl) ruthenium (TBR)-labeled bar code DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products.

  9. Moving code - Sharing geoprocessing logic on the Web

    NASA Astrophysics Data System (ADS)

    Müller, Matthias; Bernard, Lars; Kadner, Daniel

    2013-09-01

    Efficient data processing is a long-standing challenge in remote sensing. Effective and efficient algorithms are required for product generation in ground processing systems, event-based or on-demand analysis, environmental monitoring, and data mining. Furthermore, the increasing number of survey missions and the exponentially growing data volume in recent years have created demand for better software reuse as well as an efficient use of scalable processing infrastructures. Solutions that address both demands simultaneously have begun to slowly appear, but they seldom consider the possibility to coordinate development and maintenance efforts across different institutions, community projects, and software vendors. This paper presents a new approach to share, reuse, and possibly standardise geoprocessing logic in the field of remote sensing. Drawing from the principles of service-oriented design and distributed processing, this paper introduces moving-code packages as self-describing software components that contain algorithmic code and machine-readable descriptions of the provided functionality, platform, and infrastructure, as well as basic information about exploitation rights. Furthermore, the paper presents a lean publishing mechanism by which to distribute these packages on the Web and to integrate them in different processing environments ranging from monolithic workstations to elastic computational environments or "clouds". The paper concludes with an outlook toward community repositories for reusable geoprocessing logic and their possible impact on data-driven science in general.

  10. Reading Rate, Readability, and Variations in Task-Induced Processing

    ERIC Educational Resources Information Center

    Coke, Esther U.

    1976-01-01

    This study explored the hypothesis that task variables account for previous findings that reading rate is unaffected by readability. The findings suggest that when appropriate reading tasks are chosen, reading rate can be used to infer underlying processes in reading. (Author/DEP)

  11. A comparison of native GPU computing versus OpenACC for implementing flow-routing algorithms in hydrological applications

    NASA Astrophysics Data System (ADS)

    Rueda, Antonio J.; Noguera, José M.; Luque, Adrián

    2016-02-01

    In recent years GPU computing has gained wide acceptance as a simple low-cost solution for speeding up computationally expensive processing in many scientific and engineering applications. However, in most cases accelerating a traditional CPU implementation for a GPU is a non-trivial task that requires a thorough refactorization of the code and specific optimizations that depend on the architecture of the device. OpenACC is a promising technology that aims at reducing the effort required to accelerate C/C++/Fortran code on an attached multicore device. Virtually with this technology the CPU code only has to be augmented with a few compiler directives to identify the areas to be accelerated and the way in which data has to be moved between the CPU and GPU. Its potential benefits are multiple: better code readability, less development time, lower risk of errors and less dependency on the underlying architecture and future evolution of the GPU technology. Our aim with this work is to evaluate the pros and cons of using OpenACC against native GPU implementations in computationally expensive hydrological applications, using the classic D8 algorithm of O'Callaghan and Mark for river network extraction as case-study. We implemented the flow accumulation step of this algorithm in CPU, using OpenACC and two different CUDA versions, comparing the length and complexity of the code and its performance with different datasets. We advance that although OpenACC can not match the performance of a CUDA optimized implementation (×3.5 slower in average), it provides a significant performance improvement against a CPU implementation (×2-6) with by far a simpler code and less implementation effort.

  12. Evaluating the complexity of online patient education materials about brain aneurysms published by major academic institutions.

    PubMed

    Gupta, Raghav; Adeeb, Nimer; Griessenauer, Christoph J; Moore, Justin M; Patel, Apar S; Kim, Christopher; Thomas, Ajith J; Ogilvy, Christopher S

    2017-08-01

    OBJECTIVE Health care education resources are increasingly available on the Internet. A majority of people reference these resources at one point or another. A threshold literacy level is needed to comprehend the information presented within these materials. A key component of health literacy is the readability of educational resources. The National Institutes of Health (NIH) and the American Medical Association have recommended that patient education materials be written between a 4th- and a 6th-grade education level. The authors assessed the readability of online patient education materials about brain aneurysms that have been published by several academic institutions across the US. METHODS Online patient education materials about brain aneurysms were downloaded from the websites of 20 academic institutions. The materials were assessed via 8 readability scales using Readability Studio software (Oleander Software Solutions), and then were statistically analyzed. RESULTS None of the patient education materials were written at or below the NIH's recommended 6th-grade reading level. The average educational level required to comprehend the texts across all institutions, as assessed by 7 of the readability scales, was 12.4 ± 2.5 (mean ± SD). The Flesch Reading Ease Scale classified the materials as "difficult" to understand, correlating with a college-level education or higher. An ANOVA test found that there were no significant differences in readability among the materials from the institutions (p = 0.215). CONCLUSIONS Brain aneurysms affect 3.2% of adults 50 years or older across the world and can cause significant patient anxiety and uncertainty. Current patient education materials are not written at or below the NIH's recommended 4th- to 6th-grade education level.

  13. Enhancing the Radiologist-Patient Relationship through Improved Communication: A Quantitative Readability Analysis in Spine Radiology.

    PubMed

    Hansberry, D R; Donovan, A L; Prabhu, A V; Agarwal, N; Cox, M; Flanders, A E

    2017-06-01

    More than 75 million Americans have less than adequate health literacy skills according to the National Center for Education Statistics. Readability scores are used as a measure of how well populations read and understand patient education materials. The purpose of this study was to assess the readability of Web sites dedicated to patient education for radiologic spine imaging and interventions. Eleven search terms relevant to radiologic spine imaging were searched on the public Internet, and the top 10 links for each term were collected and analyzed to determine readability scores by using 10 well-validated quantitative readability assessments from patient-centered education Web sites. The search terms included the following: x-ray spine, CT spine, MR imaging spine, lumbar puncture, kyphoplasty, vertebroplasty, discogram, myelogram, cervical spine, thoracic spine, and lumbar spine. Collectively, the 110 articles were written at an 11.3 grade level (grade range, 7.1-16.9). None of the articles were written at the American Medical Association and National Institutes of Health recommended 3rd-to-7th grade reading levels. The vertebroplasty articles were written at a statistically significant ( P < .05) more advanced level than the articles for x-ray spine, CT spine, and MR imaging spine. Increasing use of the Internet to obtain health information has made it imperative that on-line patient education be written for easy comprehension by the average American. However, given the discordance between readability scores of the articles and the American Medical Association and National Institutes of Health recommended guidelines, it is likely that many patients do not fully benefit from these resources. © 2017 by American Journal of Neuroradiology.

  14. Readability of internet-sourced patient education material related to “labour analgesia”

    PubMed Central

    Boztas, Nilay; Omur, Dilek; Ozbılgın, Sule; Altuntas, Gözde; Piskin, Ersan; Ozkardesler, Sevda; Hanci, Volkan

    2017-01-01

    Abstract We evaluated the readability of Internet-sourced patient education materials (PEMs) related to “labour analgesia.” In addition to assessing the readability of websites, we aimed to compare commercial, personal, and academic websites. We used the most popular search engine (http://www.google.com) in our study. The first 100 websites in English that resulted from a search for the key words “labour analgesia” were scanned. Websites that were not in English, graphs, pictures, videos, tables, figures and list formats in the text, all punctuation, the number of words in the text is less than 100 words, feedback forms not related to education, (Uniform Resource Locator) URL websites, author information, references, legal disclaimers, and addresses and telephone numbers were excluded. The texts included in the study were assessed using the Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (FOG) readability formulae. The number of Latin words within the text was determined. Analysis of 300-word sections of the texts revealed that the mean FRES was 47.54 ± 12.54 (quite difficult), mean FKGL and SMOG were 11.92 ± 2.59 and 10.57 ± 1.88 years of education, respectively, and mean Gunning FOG was 14.71 ± 2.76 (very difficult). Within 300-word sections, the mean number of Latin words was identified as 16.56 ± 6.37. In our study, the readability level of Internet-sourced PEM related to “labour analgesia” was identified to be quite high indicating poor readability. PMID:29137057

  15. Dr Google: The readability and accuracy of patient education websites for Graves' disease treatment.

    PubMed

    Purdy, Amanda C; Idriss, Almoatazbellah; Ahern, Susan; Lin, Elizabeth; Elfenbein, Dawn M

    2017-11-01

    National guidelines emphasize the importance of incorporating patient preferences into the recommendations for the treatment of Graves' disease. Many patients use the Internet to obtain health information, and search results can affect their treatment decisions. This study compares the readability and accuracy of patient-oriented online resources for the treatment of Graves' disease by website affiliation and treatment modality. A systematic Internet search was used to identify the top websites discussing the treatment of Graves' disease. Readability was measured using 5 standardized tests. Accuracy was assessed by a blinded, expert panel, which scored the accuracy of sites on a scale of 1 to 5. Mean readability and accuracy scores were compared among website affiliations and treatment modalities. We identified 13 unique websites, including 2 academic, 2 government, 5 nonprofit, and 4 private sites. There was a difference in both readability (mean 13.2, range 9.1-15.7, P = .003) and accuracy (mean 4.04, range 2.75-4.50, P = .019) based on website affiliation. Government sites (mean readability 11.1) were easier to read than academic (14.3, P < .01), nonprofit (13.9, P < .01), and private sites (13.5, P < .05). Academic sites (mean accuracy 4.50) were more accurate than private sites (3.56, P < .05). Online patient resources for the treatment of Graves' disease are written at an inappropriately high reading level. Academic sites contain both the most accurate and the most difficult to read information. Private sites represented the majority of our top results but contained the least accurate information. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Readability of Online Patient Education Materials Related to IR.

    PubMed

    McEnteggart, Gregory E; Naeem, Muhammad; Skierkowski, Dorothy; Baird, Grayson L; Ahn, Sun H; Soares, Gregory

    2015-08-01

    To assess the readability of online patient education materials (OPEM) related to common diseases treated by and procedures performed by interventional radiology (IR). The following websites were chosen based on their average Google search return for each IR OPEM content area examined in this study: Society of Interventional Radiology (SIR), Cardiovascular and Interventional Radiological Society of Europe (CIRSE), National Library of Medicine, RadiologyInfo, Mayo Clinic, WebMD, and Wikipedia. IR OPEM content area was assessed for the following: peripheral arterial disease, central venous catheter, varicocele, uterine artery embolization, vertebroplasty, transjugular intrahepatic portosystemic shunt, and deep vein thrombosis. The following algorithms were used to estimate and compare readability levels: Flesch-Kincaid Grade Formula, Flesch Reading Ease Score, Gunning Frequency of Gobbledygook, Simple Measure of Gobbledygook, and Coleman-Liau Index. Data were analyzed using general mixed modeling. On average, online sources that required beyond high school grade-level readability were Wikipedia (15.0), SIR (14.2), and RadiologyInfo (12.4); sources that required high school grade-level readability were CIRSE (11.3), Mayo Clinic (11.0), WebMD (10.6), and National Library of Medicine (9.0). On average, OPEM on uterine artery embolization, vertebroplasty, varicocele, and peripheral arterial disease required the highest level of readability (12.5, 12.3, 12.3, and 12.2, respectively). The IR OPEM assessed in this study were written above the recommended sixth-grade reading level and the health literacy level of the average American adult. Many patients in the general public may not have the ability to read and understand health information in IR OPEM. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  17. Online patient information from radiation oncology departments is too complex for the general population.

    PubMed

    Rosenberg, Stephen A; Francis, David M; Hullet, Craig R; Morris, Zachary S; Brower, Jeffrey V; Anderson, Bethany M; Bradley, Kristin A; Bassetti, Michael F; Kimple, Randall J

    Nearly two-thirds of cancer patients seek information about their diagnosis online. We assessed the readability of online patient education materials found on academic radiation oncology department Web sites to determine whether they adhered to guidelines suggesting that information be presented at a sixth-grade reading level. The Association of American Medical Colleges Web site was used to identify all academic radiation oncology departments in the United States. One-third of these department Web sites were selected for analysis using a random number generator. Both general information on radiation therapy and specific information regarding various radiation modalities were collected. To test the hypothesis that the readability of these online educational materials was written at the recommended grade level, a panel of 10 common readability tests was used. A composite grade level of readability was constructed using the 8 readability measures that provide a single grade-level output. A mean of 5605 words (range, 2058-12,837) from 30 department Web sites was collected. Using the composite grade level score, the overall mean readability level was determined to be 13.36 (12.83-13.89), corresponding to a collegiate reading level. This was significantly higher than the target sixth-grade reading level (middle school, t (29) = 27.41, P < .001). Online patient educational materials from academic radiation oncology Web sites are significantly more complex than recommended by the National Institutes of Health and the Department of Health and Human Services. To improve patients' comprehension of radiation therapy and its role in their treatment, our analysis suggests that the language used in online patient information should be simplified to communicate the information at a more appropriate level. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  18. Comparative Readability of Shoulder and Elbow Patient Education Materials within Orthopaedic Websites.

    PubMed

    Beutel, Bryan G; Danna, Natalie R; Melamed, Eitan; Capo, John T

    2015-12-01

    There is growing concern that the readability of online orthopaedic patient education materials are too difficult for the general public to fully understand. It is recommended that this information be at the sixth grade reading level or lower. This study compared the readability of shoulder and elbow education articles from the American Academy of Orthopaedic Surgeons (AAOS) and American Society for Surgery of the Hand (ASSH) websites. Seventy-six patient education articles from the AAOS and ASSH concerning shoulder and elbow disorders were evaluated. Each article was assessed for the number of years since its last update, word count, percentage of passive sentences, Flesch Reading Ease score, Flesch-Kincaid grade level, Simple Measure of Gobbledygook (SMOG) grade, and New Dale-Chall grade level. Only one article was at or below the sixth grade reading level. The AAOS and ASSH articles had the following respective scores: a mean Flesch Reading Ease score of 54.3 and 51.8, Flesch-Kincaid grade level of 9.4 and 10.3, SMOG grade of 8.5 and 9.4, and New Dale-Chall grade of 10.4 and 11.0. Articles from the AAOS were longer (p < 0.001), had a lower percentage of passive sentences (p < 0.001), and were more recently updated (p = 0.02) than their ASSH counterparts. Higher percentages of passive sentences were found to correlate with more difficult readability. Patient education materials regarding the shoulder and elbow on the AAOS and ASSH websites have readability scores above the recommended reading level. These may be too challenging for the majority of patients to read and consequently serve as a barrier to proper patient education. Reducing the percentage of passive sentences may serve as a novel target for improving readability.

  19. Mobile applications and patient education: Are currently available GERD mobile apps sufficient?

    PubMed

    Bobian, Michael; Kandinov, Aron; El-Kashlan, Nour; Svider, Peter F; Folbe, Adam J; Mayerhoff, Ross; Eloy, Jean Anderson; Raza, S Naweed

    2017-08-01

    Despite the increasing role of mobile applications (apps) in patient education, there has been little inquiry evaluating the quality of these resources. Because poor health literacy has been associated with inferior health outcomes, evaluating the quality of patient education materials takes on great importance. Our objective was to employ validated readability tools for the evaluation of gastroesophageal reflux (GERD) mobile apps. GERD-specific apps found in the Apple App Store (Apple Inc., Cupertino CA) were evaluated using the Readability Studio Professional Version 2015 for Windows (Oleander Software, Ltd, Vandalia, OH). All text was evaluated using nine validated algorithms measuring readability including Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook grading, Gunning Fog index, Coleman-Liau, New Fog Count formula, Raygor Readability Estimate, FORCAST, Fry graph, and Flesch Reading Ease score. Average reading grade levels for individual GERD apps ranged from 9.6 to 12.9 (interquartile range 10.3-12). The average reading grade level for all apps analyzed was 11.1 ± 0.2 standard error of the mean (SEM), with an average Flesch Reading Ease score for all mobile apps analyzed of 51 ± 2.05 (SEM), falling into the "fairly difficult" category given by this measure. Raygor Readability estimates that most mobile apps have a reading grade level between 10 and 12, with the majority of this outcome due to long words. This analysis demonstrates the feasibility of assessing readability of mobile health apps. Our findings suggest significant gaps in potential comprehension between the apps analyzed and the average reader, diminishing the utility of these resources. We hope our findings influence future mobile health-related app development and thereby improve patient outcomes in GERD and other chronic diseases. NA. Laryngoscope, 127:1775-1779, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Object-oriented numerics with FOSS: comparing PyPy &amp; NumPy, GCC/Clang &amp; Bitz++ and Gfortran

    NASA Astrophysics Data System (ADS)

    Jarecka, Dorota; Arabas, Sylwester; Fijalkowski, Maciej; Jaruga, Anna; Del Vento, Davide

    2013-04-01

    Employment of object-oriented programming (OOP) techniques may help to improve code readability, and hence its auditability and maintainability - both being arguably crucial for scientific software. OOP offers, in particular, the possibility to reproduce in the program code the mathematical "blackboard abstractions" used in the literature. There exist a number of free and open-source tools allowing to obtain this goal without sacrificing performance. An OOP implementation of the MPDATA advection algorithm used as a core of weather, ocean and climate modelling systems will serve as an example for briefly highlighting some relevant recent FOSS developments including: - NumPy support in the PyPy just-in-time compiler of Python. - the Blitz++ library coupled with the C++11 support in GCC and Clang; - support for OOP constructs from Fortran 2003/2008 in GFortran; A brief overview of other performance-related packages for Python like Numba and Cython will be also given. This poster will describe and extends key findings presented in http://arxiv.org/abs/1301.1334

  1. Quantitative Analysis of Science and Chemistry Textbooks for Indicators of Reform: A complementary perspective

    NASA Astrophysics Data System (ADS)

    Kahveci, Ajda

    2010-07-01

    In this study, multiple thematically based and quantitative analysis procedures were utilized to explore the effectiveness of Turkish chemistry and science textbooks in terms of their reflection of reform. The themes gender equity, questioning level, science vocabulary load, and readability level provided the conceptual framework for the analyses. An unobtrusive research method, content analysis, was used by coding the manifest content and counting the frequency of words, photographs, drawings, and questions by cognitive level. The context was an undergraduate chemistry teacher preparation program at a large public university in a metropolitan area in northwestern Turkey. Forty preservice chemistry teachers were guided to analyze 10 middle school science and 10 high school chemistry textbooks. Overall, the textbooks included unfair gender representations, a considerably higher number of input and processing than output level questions, and high load of science terminology. The textbooks failed to provide sufficient empirical evidence to be considered as gender equitable and inquiry-based. The quantitative approach employed for evaluation contrasts with a more interpretive approach, and has the potential in depicting textbook profiles in a more reliable way, complementing the commonly employed qualitative procedures. Implications suggest that further work in this line is needed on calibrating the analysis procedures with science textbooks used in different international settings. The procedures could be modified and improved to meet specific evaluation needs. In the Turkish context, next step research may concern the analysis of science textbooks being rewritten for the reform-based curricula to make cross-comparisons and evaluate a possible progression.

  2. Evaluating asthma websites using the Brief DISCERN instrument.

    PubMed

    Banasiak, Nancy Cantey; Meadows-Oliver, Mikki

    2017-01-01

    The primary purpose of this study was to examine the quality of sponsored and unsponsored asthma websites using the Brief DISCERN instrument and to evaluate whether the Health On the Net Code of Conduct (HONcode) logo was present, thereby indicating that the site met the criteria. The Internet is an important source of health information for patients and their families. The primary purpose of this study was to examine the quality of sponsored and unsupported asthma websites. A secondary aim was to determine the readability and reading ease of the materials for each website along with the grade level. We queried seven Internet search engines using the keyword "asthma." The websites were evaluated using the six-item Brief DISCERN instrument and by ascertaining whether the HONcode quality label was present. The websites were also evaluated for readability employing Flesch-Kincaid grade level and Flesch reading ease tools using Microsoft Office Word 2013 software. A total of 22 unique websites were included in the study. Approximately 68% of the websites reviewed had a Brief DISCERN cutoff score of ≥16. The overall Brief DISCERN scores ranged from 6 to 30, and the mean score was 17.32 (SD =6.71). The Flesch-Kincaid grade level scores ranged from 2.9 to 15.4, and the average reading grade score was 9.49 (SD =2.7). The Flesch reading ease scores ranged from 17 to 82.7, with a mean reading ease score of 53.57 (SD =15.03). Sites with a HONcode quality label had significantly higher Brief DISCERN scores than those without one ( t =2.3795; df =20; p =0.02). Brief DISCERN scores revealed that there is quality asthma information for children and their families available on the Internet. The grade level ranged between 2.9 and 15.4 among the websites. However, the mean grade level scores were 9.3-9.89, which is high for the average consumer. Access to accurate information via the Internet, with appropriate readability, may enable pediatric asthma patients and their caregivers to better control and manage asthma.

  3. Evaluating asthma websites using the Brief DISCERN instrument

    PubMed Central

    Banasiak, Nancy Cantey; Meadows-Oliver, Mikki

    2017-01-01

    Purpose The primary purpose of this study was to examine the quality of sponsored and unsponsored asthma websites using the Brief DISCERN instrument and to evaluate whether the Health On the Net Code of Conduct (HONcode) logo was present, thereby indicating that the site met the criteria. The Internet is an important source of health information for patients and their families. The primary purpose of this study was to examine the quality of sponsored and unsupported asthma websites. A secondary aim was to determine the readability and reading ease of the materials for each website along with the grade level. Methods We queried seven Internet search engines using the keyword “asthma.” The websites were evaluated using the six-item Brief DISCERN instrument and by ascertaining whether the HONcode quality label was present. The websites were also evaluated for readability employing Flesch-Kincaid grade level and Flesch reading ease tools using Microsoft Office Word 2013 software. Results A total of 22 unique websites were included in the study. Approximately 68% of the websites reviewed had a Brief DISCERN cutoff score of ≥16. The overall Brief DISCERN scores ranged from 6 to 30, and the mean score was 17.32 (SD =6.71). The Flesch-Kincaid grade level scores ranged from 2.9 to 15.4, and the average reading grade score was 9.49 (SD =2.7). The Flesch reading ease scores ranged from 17 to 82.7, with a mean reading ease score of 53.57 (SD =15.03). Sites with a HONcode quality label had significantly higher Brief DISCERN scores than those without one (t=2.3795; df=20; p=0.02). Conclusion Brief DISCERN scores revealed that there is quality asthma information for children and their families available on the Internet. The grade level ranged between 2.9 and 15.4 among the websites. However, the mean grade level scores were 9.3–9.89, which is high for the average consumer. Access to accurate information via the Internet, with appropriate readability, may enable pediatric asthma patients and their caregivers to better control and manage asthma. PMID:28670135

  4. Performance Analysis of a De-correlated Modified Code Tracking Loop for Synchronous DS-CDMA System under Multiuser Environment

    NASA Astrophysics Data System (ADS)

    Wu, Ya-Ting; Wong, Wai-Ki; Leung, Shu-Hung; Zhu, Yue-Sheng

    This paper presents the performance analysis of a De-correlated Modified Code Tracking Loop (D-MCTL) for synchronous direct-sequence code-division multiple-access (DS-CDMA) systems under multiuser environment. Previous studies have shown that the imbalance of multiple access interference (MAI) in the time lead and time lag portions of the signal causes tracking bias or instability problem in the traditional correlating tracking loop like delay lock loop (DLL) or modified code tracking loop (MCTL). In this paper, we exploit the de-correlating technique to combat the MAI at the on-time code position of the MCTL. Unlike applying the same technique to DLL which requires an extensive search algorithm to compensate the noise imbalance which may introduce small tracking bias under low signal-to-noise ratio (SNR), the proposed D-MCTL has much lower computational complexity and exhibits zero tracking bias for the whole range of SNR, regardless of the number of interfering users. Furthermore, performance analysis and simulations based on Gold codes show that the proposed scheme has better mean square tracking error, mean-time-to-lose-lock and near-far resistance than the other tracking schemes, including traditional DLL (T-DLL), traditional MCTL (T-MCTL) and modified de-correlated DLL (MD-DLL).

  5. Comparison of Online Dementia Information in Chinese and in English Languages

    PubMed Central

    Tsiang, John T

    2017-01-01

    Introduction There is a deficit of avenues for obtaining dementia information in the Asian American community. This study aims to compare the content and quality differences between websites providing information on dementia as found by a Google search conducted both in simplified Chinese characters and in English. Methods A Google search was performed for the phrase “dementia” in simplified Chinese characters and in English. The resultant websites were categorized by whether they were commercial in nature, the type of website, and whether the website provided an explanation of dementia signs and symptoms. The quality of the websites was assessed via readability and the Health on the Net Code of Conduct (HONcode). Chi-squared analyses were performed to establish differences between the English and simplified Chinese results. Results The simplified Chinese search websites were more likely to be commercial (p=0.045) and were more likely to not meet HONcode standards (p=0.008). No statistical significance was observed between the types of websites (p=0.127), the prevalence of signs and symptom explanations (p=0.073), and the readability of the website (p=0.151). Conclusion The quality of websites obtained from the simplified Chinese character Google search was lower than those obtained from searches using the English language. Given the limited sources of language and culturally appropriate information on dementia, improvement of Internet resources may help to improve health outcomes of dementia patients in the Asian American population. PMID:29308336

  6. Readability of self-illuminated signs obscured by black fuel-fire smoke.

    DOT National Transportation Integrated Search

    1980-07-01

    This study, using black fuel-fire generated smoke, is a partial replication of an earlier study using an inert white smoke as the obscuring agent in the study of the readability of smoke-obscured, self-illuminated emergency exit signs. : The results ...

  7. Assessment of the quality and content of website health information about herbal remedies for menopausal symptoms.

    PubMed

    Sowter, Julie; Astin, Felicity; Dye, Louise; Marshall, Paul; Knapp, Peter

    2016-06-01

    To assess the quality, readability and coverage of website information about herbal remedies for menopausal symptoms. A purposive sample of commercial and non-commercial websites was assessed for quality (DISCERN), readability (SMOG) and information coverage. Non-parametric and parametric tests were used to explain the variability of these factors across types of websites and to assess associations between website quality and information coverage. 39 sites were assessed. Median quality and information coverage scores were 44/80 and 11/30 respectively. The median readability score was 18.7, similar to UK broadsheets. Commercial websites scored significantly lower on quality (p=0.014), but there were no statistical differences for information coverage or readability. There was a significant positive correlation between information quality and coverage scores irrespective of website provider (r=0.69, p<0.001, n=39). Overall website quality and information coverage are poor and the required reading level high. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Are condom instructions readable? Results of a readability study.

    PubMed Central

    Richwald, G A; Wamsley, M A; Coulson, A H; Morisky, D E

    1988-01-01

    The use of condoms has assumed a central position in the current strategy to prevent sexual transmission of the human immunodeficiency virus. The effectiveness of condoms in disease prophylaxis is dependent, to a degree, on their correct use. Condom manufacturers routinely include information on condom use either printed on the actual package or in an enclosed package insert. With the use of three readability formulas, the reading grade level was determined for 14 different sets of instructions included with 25 brands of condoms manufactured by 7 domestic and 1 overseas manufacturer. The readability formulas, when applied to instructions for condom use, estimated that, conservatively, 8 of the 14 instructions required at least reading at the level of a high school graduate and none required less than a 10th grade level. Clearly written instructions and simple concepts could assist current and future condom users in the correct use of condoms and improve the effectiveness of condoms in the prevention of AIDS and other sexually transmitted diseases. PMID:3136494

  9. Nuclear Medicine and Resources for Patients: How Complex are Online Patient Educational Materials?

    PubMed

    Hansberry, David R; Shah, Kush; Agarwal, Nitin; Kim, Sung M; Intenzo, Charles M

    2018-02-02

    The Internet is a major source of healthcare information for patients. The American Medical Association and National Institutes of Health recommend that consumer healthcare websites be written between a 3rd and 7th grade level. The purpose of this study is to evaluate the level of readability of patient education websites pertaining to nuclear medicine. Methods: Ten search terms were Googled and the top 10 links for each term were collected and analyzed for their level of readability using 10 well-established readability scales. Results: Collectively the 99 articles were written at an 11.8 grade level (standard deviation of 3.4). Only 5 of the 99 articles were written at the NIH and AMA recommended 3rd to 7th grade. Conclusion: There is a clear discordance between the readability level of nuclear medicine related imaging terms with the NIH and AMA guidelines. This disconnect may negatively impact patient understanding contributing to poor health outcomes. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Readability assessment of online thyroid surgery patient education materials.

    PubMed

    Patel, Chirag R; Cherla, Deepa V; Sanghvi, Saurin; Baredes, Soly; Eloy, Jean Anderson

    2013-10-01

    Published guidelines recommend written health information be written at or below the sixth-grade level. We evaluate the readability of online materials related to thyroid surgery. Thyroid surgery materials were evaluated using Flesch Reading Ease Score (FRES), Flesch Kincaid Grade Level (FKGL), Gunning Frequency of Gobbledygook (GFOG), and Simple Measure of Gobbledygook (SMOG). Thirty-one documents were evaluated. FRES scores ranged from 29.3 to 67.8 (possible range = 0 to 100), and averaged 50.5. FKGL ranged from 6.9 to 14.9 (possible range = 3 to 12), and averaged 10.4. SMOG scores ranged from 11.8 to 14.5 (possible range = 3 to 19), and averaged 13.0. GFOG scores ranged from 10.6 to 18.0 (possible range = 3 to 19), and averaged 13.5. Readability scores for online thyroid surgery materials are higher (i.e., more difficult) than the recommended levels. However, readability is only one aspect of comprehension. Written information should be designed with that fact in mind. Copyright © 2013 Wiley Periodicals, Inc.

  11. Quality and readability of information materials for people with brain tumours and their families.

    PubMed

    Langbecker, Danette; Janda, Monika

    2012-12-01

    Written information is commonly used to inform patients about their disease and treatment but must be evidence-based and understandable to be useful. This study assessed the quality of the content and the readability of information brochures for people affected by brain tumours. We randomly selected 18 publicly available brochures. Brochures were assessed by criteria to assess the quality of content using the DISCERN instrument. Readability was tested using three commonly used formulas, which yield the reading grade level required to comprehend the brochure (sixth grade level recommended). The mean overall DISCERN score was 3.17 out of a maximum of 5 (moderate quality); only one achieved a rating greater than 4 (high quality). Only one brochure met the sixth grade readability criteria. Although brochures may have accurate content, few satisfied all of the recommended criteria to evaluate their content. Existing brochures need to be critically reviewed and simplified and consumer-focused brochures, produced.

  12. Online Health Information Regarding Male Infertility: An Evaluation of Readability, Suitability, and Quality

    PubMed Central

    Robins, Stephanie; Barr, Helena J; Idelson, Rachel; Lambert, Sylvie

    2016-01-01

    Background Many men lack knowledge about male infertility, and this may have consequences for their reproductive and general health. Men may prefer to seek health information online, but these sources of information vary in quality. Objective The objective of this study is to determine if online sources of information regarding male infertility are readable, suitable, and of appropriate quality for Internet users in the general population. Methods This study used a cross-sectional design to evaluate online sources resulting from search engine queries. The following categories of websites were considered: (1) Canadian fertility clinics, (2) North American organizations related to fertility, and (3) the first 20 results of Google searches using the terms “male infertility” and “male fertility preservation” set to the search locations worldwide, English Canada, and French Canada. Websites that met inclusion criteria (N=85) were assessed using readability indices, the Suitability Assessment of Materials (SAM), and the DISCERN tool. The associations between website affiliation (government, university/medical, non-profit organization, commercial/corporate, private practice) and Google placement to readability, suitability, and quality were also examined. Results None of the sampled websites met recommended levels of readability. Across all websites, the mean SAM score for suitability was 45.37% (SD 11.21), or “adequate”, while the DISCERN mean score for quality was 43.19 (SD 10.46) or “fair”. Websites that placed higher in Google obtained a higher overall score for quality with an r (58) value of -.328 and a P value of .012, but this position was not related to readability or suitability. In addition, 20% of fertility clinic websites did not include fertility information for men. Conclusions There is a lack of high quality online sources of information on male fertility. Many websites target their information to women, or fail to meet established readability criteria for the general population. Since men may prefer to seek health information online, it is important that health care professionals develop high quality sources of information on male fertility for the general population. PMID:27769954

  13. Documentation for the machine-readable version of the Revised S210 Catalog of Far-Ultraviolet Objects (Page, Carruthers and Heckathorn 1982)

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1984-01-01

    A detailed description of the machine-readable revised catalog as it is currently being distributed from the Astronomical Data Center is given. This catalog of star images was compiled from imagery obtained by the Naval Research Laboratory (NRL) Far-Ultraviolet Camera/Spectrograph (Experiments S201) operated from 21 to 23 April 1972 on the lunar surface during the Apollo 16 mission. The documentation includes a detailed data format description, a table of indigenous characteristics of the magnetic tape file, and a sample listing of data records exactly as they are presented in the machine-readable version.

  14. Developing and Modifying Behavioral Coding Schemes in Pediatric Psychology: A Practical Guide

    PubMed Central

    McMurtry, C. Meghan; Chambers, Christine T.; Bakeman, Roger

    2015-01-01

    Objectives To provide a concise and practical guide to the development, modification, and use of behavioral coding schemes for observational data in pediatric psychology. Methods This article provides a review of relevant literature and experience in developing and refining behavioral coding schemes. Results A step-by-step guide to developing and/or modifying behavioral coding schemes is provided. Major steps include refining a research question, developing or refining the coding manual, piloting and refining the coding manual, and implementing the coding scheme. Major tasks within each step are discussed, and pediatric psychology examples are provided throughout. Conclusions Behavioral coding can be a complex and time-intensive process, but the approach is invaluable in allowing researchers to address clinically relevant research questions in ways that would not otherwise be possible. PMID:25416837

  15. 48 CFR 252.211-7003 - Item unique identification and valuation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reader or interrogator, used to retrieve data encoded on machine-readable media. Concatenated unique item... identifier. Item means a single hardware article or a single unit formed by a grouping of subassemblies... manufactured under identical conditions. Machine-readable means an automatic identification technology media...

  16. Reference Manual for Machine-Readable Bibliographic Descriptions. Second Revised Edition.

    ERIC Educational Resources Information Center

    Dierickx, H., Ed.; Hopkinson, A., Ed.

    A product of the UNISIST International Centre for Bibliographic Descriptions (UNIBIB), this reference manual presents a standardized communication format for the exchange of machine-readable bibliographic information between bibliographic databases or other types of bibliographic information services, including libraries. The manual is produced in…

  17. Critical Analysis of the Quality, Readability, and Technical Aspects of Online Information Provided for Neck-Lifts.

    PubMed

    Rayess, Hani; Zuliani, Giancarlo F; Gupta, Amar; Svider, Peter F; Folbe, Adam J; Eloy, Jean Anderson; Carron, Michael A

    2017-03-01

    The number of patients using the internet to obtain health information is growing. This material is unregulated and heterogeneous and can influence patient decisions. To compare the quality, readability, and technical aspects of online information about neck-lifts provided by private practice websites vs academic medical centers and reference sources. In this cross-sectional analysis conducted between November 2015 and January 2016, a Google search of the term neck-lift was performed, and the first 45 websites were evaluated. The websites were categorized as private practice vs other. Private websites (PWs) included sites created by private practice physicians. Other websites (OWs) were created by academic medical centers or reference sources. Quality, readability, and technical aspects of online websites related to neck-lifts. Quality was assessed using the DISCERN criteria and the Health on the Net principles (HONcode). Readability was assessed using 7 validated and widely used criteria. Consensus US reading grade level readability was provided by a website (readabilityformulas.com). Twelve technical aspects were evaluated based on criteria specified by medical website creators. Forty-five websites (8 OWs [18%] and 37 PWs [82%]) were analyzed. There was a significant difference in quality between OWs and PWs based on the DISCERN criteria and HONcode principles. The DISCERN overall mean (SD) scores were 2.3 (0.5) for OWs and 1.3 (0.3) for PWs (P < .001). Of a total possible score of 14 using the HONcode analysis, the mean (SD) was 8.6 (1.8) (range, 5-11) for OW, and the mean (SD) was 5.8 (1.7) (range, 2-9) for PW. The mean (SD) readability consensus reading grade level scores were 11.7 (1.9) for OWs and 10.6 (1.9) for PWs. Of a total possible score of 12, the mean (SD) technical scores were 6.3 (1.8) (range, 4-9) for OWs and 6.4 (1.5) (range, 3-9) for PWs. Compared with PWs, OWs had a significantly higher quality score based on both the DISCERN criteria and HONcode principles. The mean readability for OWs and PWs was grade 11 and grade 10, respectively, significantly higher than the grade 7 level recommended by the National Institutes of Health. Assessment of technical criteria demonstrated room for improvement in providing links to social media and blogs and reducing advertisements. Improving the quality and readability of online information may result in increased patient understanding, more active patient involvement, and ultimately better outcomes. Enhancing the technical aspects of websites may increase website traffic and patient volume. NA.

  18. DNA fingerprinting of Chinese melon provides evidentiary support of seed quality appraisal.

    PubMed

    Gao, Peng; Ma, Hongyan; Luan, Feishi; Song, Haibin

    2012-01-01

    Melon, Cucumis melo L. is an important vegetable crop worldwide. At present, there are phenomena of homonyms and synonyms present in the melon seed markets of China, which could cause variety authenticity issues influencing the process of melon breeding, production, marketing and other aspects. Molecular markers, especially microsatellites or simple sequence repeats (SSRs) are playing increasingly important roles for cultivar identification. The aim of this study was to construct a DNA fingerprinting database of major melon cultivars, which could provide a possibility for the establishment of a technical standard system for purity and authenticity identification of melon seeds. In this study, to develop the core set SSR markers, 470 polymorphic SSRs were selected as the candidate markers from 1219 SSRs using 20 representative melon varieties (lines). Eighteen SSR markers, evenly distributed across the genome and with the highest contents of polymorphism information (PIC) were identified as the core marker set for melon DNA fingerprinting analysis. Fingerprint codes for 471 melon varieties (lines) were established. There were 51 materials which were classified into17 groups based on sharing the same fingerprint code, while field traits survey results showed that these plants in the same group were synonyms because of the same or similar field characters. Furthermore, DNA fingerprinting quick response (QR) codes of 471 melon varieties (lines) were constructed. Due to its fast readability and large storage capacity, QR coding melon DNA fingerprinting is in favor of read convenience and commercial applications.

  19. DNA Fingerprinting of Chinese Melon Provides Evidentiary Support of Seed Quality Appraisal

    PubMed Central

    Gao, Peng; Ma, Hongyan; Luan, Feishi; Song, Haibin

    2012-01-01

    Melon, Cucumis melo L. is an important vegetable crop worldwide. At present, there are phenomena of homonyms and synonyms present in the melon seed markets of China, which could cause variety authenticity issues influencing the process of melon breeding, production, marketing and other aspects. Molecular markers, especially microsatellites or simple sequence repeats (SSRs) are playing increasingly important roles for cultivar identification. The aim of this study was to construct a DNA fingerprinting database of major melon cultivars, which could provide a possibility for the establishment of a technical standard system for purity and authenticity identification of melon seeds. In this study, to develop the core set SSR markers, 470 polymorphic SSRs were selected as the candidate markers from 1219 SSRs using 20 representative melon varieties (lines). Eighteen SSR markers, evenly distributed across the genome and with the highest contents of polymorphism information (PIC) were identified as the core marker set for melon DNA fingerprinting analysis. Fingerprint codes for 471 melon varieties (lines) were established. There were 51 materials which were classified into17 groups based on sharing the same fingerprint code, while field traits survey results showed that these plants in the same group were synonyms because of the same or similar field characters. Furthermore, DNA fingerprinting quick response (QR) codes of 471 melon varieties (lines) were constructed. Due to its fast readability and large storage capacity, QR coding melon DNA fingerprinting is in favor of read convenience and commercial applications. PMID:23285039

  20. Online Tonsillectomy Resources: Are Parents Getting Consistent and Readable Recommendations?

    PubMed

    Wozney, Lori; Chorney, Jill; Huguet, Anna; Song, Jin Soo; Boss, Emily F; Hong, Paul

    2017-05-01

    Objective Parents frequently refer to information on the Internet to confirm or broaden their understanding of surgical procedures and to research postoperative care practices. Our study evaluated the readability, comprehensiveness, and consistency around online recommendations directed at parents of children undergoing tonsillectomy. Study Design A cross-sectional study design was employed. Setting Thirty English-language Internet websites. Subjects and Methods Three validated measures of readability were applied and content analysis was employed to evaluate the comprehensiveness of information in domains of perioperative education. Frequency effect sizes and percentile ranks were calculated to measure dispersion of recommendations across sites. Results The mean readability level of all sites was above a grade 10 level with fewer than half of the sites (n = 14, 47%) scoring at or below the eight-grade level. Provided information was often incomplete with a noted lack of psychosocial support and skills-training recommendations. Content analysis showed 67 unique recommendations spanning the full perioperative period. Most recommendations had low consensus, being reported in 5 or fewer sites (frequency effect size <16%). Conclusion Many online parent-focused resources do not meet readability recommendations, portray incomplete education about perioperative care and expectations, and provide recommendations with low levels of consensus. Up-to-date mapping of the research evidence around recommendations is needed as well as improved efforts to make online information easier to read.

  1. Readability of consumer health information on the internet: a comparison of U.S. government-funded and commercially funded websites.

    PubMed

    Risoldi Cochrane, Zara; Gregory, Philip; Wilson, Amy

    2012-01-01

    The Internet has become an extremely prevalent means of communicating health information to consumers. Guidelines for selecting reliable health information websites give preference to U.S. government sites over commercially funded sites. However, these websites are not useful to consumers unless they are able to read and understand them. The authors' objective was to compare the readability of Internet health information intended for consumers found on U.S. government-funded websites versus that found on commercially funded websites. Consumer health websites were identified through a systematic Internet search. Webpages for 10 common health topics were extracted from each website. Readability of webpages was determined by 3 validated measures: Flesch Reading Ease, Flesch-Kincaid Reading Level, and SMOG Formula. Mean readability of government-funded and commercially funded websites was compared using the Mann-Whitney U test. Commercially funded websites were significantly more difficult to read as measured by Flesch Reading Ease (49.7 vs. 55.6 for government-funded sites, p = .002) and Flesch-Kincaid Reading Level (10.1 vs. 9.3, p = .012). There was no significant difference according to SMOG Formula (12.8 vs. 13.2, p = .150). The overall readability of Internet health information intended for consumers was poor. Efforts should be made to ensure that health information communicated via the Internet is easy for consumers to read and understand.

  2. Health Literacy Demands of Patient-Reported Evaluation Tools in Orthopedics: A Mixed-Methods Case Study.

    PubMed

    Hadden, Kristie; Prince, Latrina Y; Barnes, C Lowry

    In response to an assessment of organizational health literacy practices at a major academic health center, this case study evaluated the health literacy demands of patient-reported outcome measures commonly used in orthopedic surgery practices to identify areas for improvement. A mixed-methods approach was used to analyze the readability and patient feedback of orthopedic patient-reported outcome materials. Qualitative results were derived from focus group notes, observations, recordings, and consensus documents. Results were combined to formulate recommendations for quality improvement. Readability results indicated that narrative portions of sample patient outcome tools were written within or below the recommended eighth-grade reading level (= 5.9). However, document literacy results were higher than the recommended reading level (= 9.8). Focus group results revealed that participants had consensus on 8 of 12 plain language best practices, including use of bullet lists and jargon or technical words in both instruments. Although the typical readability of both instruments was not exceedingly high, appropriate readability formula and assessment methods gave a more comprehensive assessment of true readability. In addition, participant feedback revealed the need to reduce jargon and improve formatting to lessen the health literacy demands on patients. As clinicians turn more toward patient-reported measures to assess health care quality, it is important to consider the health literacy demands that are inherent in the instruments they are given in our health systems.

  3. Evaluation of the Informational Content, Readability and Comprehensibility of Online Health Information on Monogenic Diabetes.

    PubMed

    Guan, Yue; Maloney, Kristin A; Roter, Debra L; Pollin, Toni I

    2018-06-01

    The purpose of this study was to assess the informational content, readability, suitability and comprehensibility of websites offering educational information about monogenic diabetes available to patients. The top 20 results from 15 queries in four search engines were screened. Content analysis was performed by two independent coders. Readability was determined using Flesch-Kincaid grade level (FKGL) and Simplified Measure of Goobledygook (SMOG). The Comprehensibility Assessment of Materials (SAM + CAM) scale was utilized to evaluate website suitability and comprehensibility. Only 2% (N = 29) of 1200 screened websites met inclusion criteria. Content analysis showed that 16 websites presented information on at least the most common forms of MODY (1, 2 and 3), four addressed the utility of genetic counseling, and none included support resources for patients. All websites exceeded the consensus readability level (6th grade) as assessed by FKGL (10.1 grade) and SMOG (12.8 ± 1.5 grades). Although the majority (N = 20) of websites had an overall "adequate" to "superior" quality score (SAM + CAM score > = 40%), more than one-third scored "not suitable" in categories of content, literacy demand, graphics, and learning motivation. The online educational resources for monogenic diabetes have a high readability level and require improvement in ease of use and comprehensibility for patients with diabetes.

  4. [Systematic Readability Analysis of Medical Texts on Websites of German University Clinics for General and Abdominal Surgery].

    PubMed

    Esfahani, B Janghorban; Faron, A; Roth, K S; Grimminger, P P; Luers, J C

    2016-12-01

    Background: Besides the function as one of the main contact points, websites of hospitals serve as medical information portals. As medical information texts should be understood by any patients independent of the literacy skills and educational level, online texts should have an appropriate structure to ease understandability. Materials and Methods: Patient information texts on websites of clinics for general surgery at German university hospitals (n = 36) were systematically analysed. For 9 different surgical topics representative medical information texts were extracted from each website. Using common readability tools and 5 different readability indices the texts were analysed concerning their readability and structure. The analysis was furthermore stratified in relation to geographical regions in Germany. Results: For the definite analysis the texts of 196 internet websites could be used. On average the texts consisted of 25 sentences and 368 words. The reading analysis tools congruously showed that all texts showed a rather low readability demanding a high literacy level from the readers. Conclusion: Patient information texts on German university hospital websites are difficult to understand for most patients. To fulfill the ambition of informing the general population in an adequate way about medical issues, a revision of most medical texts on websites of German surgical hospitals is recommended. Georg Thieme Verlag KG Stuttgart · New York.

  5. Aeromechanical stability analysis of COPTER

    NASA Technical Reports Server (NTRS)

    Yin, Sheng K.; Yen, Jing G.

    1988-01-01

    A plan was formed for developing a comprehensive, second-generation system with analytical capabilities for predicting performance, loads and vibration, handling qualities, aeromechanical stability, and acoustics. This second-generation system named COPTER (COmprehensive Program for Theoretical Evaluation of Rotorcraft) is designed for operational efficiency, user friendliness, coding readability, maintainability, transportability, modularity, and expandability for future growth. The system is divided into an executive, a data deck validator, and a technology complex. At present a simple executive, the data deck validator, and the aeromechanical stability module of the technology complex were implemented. The system is described briefly, the implementation of the technology module is discussed, and correlation data presented. The correlation includes hingeless-rotor isolated stability, hingeless-rotor ground-resonance stability, and air-resonance stability of an advanced bearingless-rotor in forward flight.

  6. Expyriment: a Python library for cognitive and neuroscientific experiments.

    PubMed

    Krause, Florian; Lindemann, Oliver

    2014-06-01

    Expyriment is an open-source and platform-independent lightweight Python library for designing and conducting timing-critical behavioral and neuroimaging experiments. The major goal is to provide a well-structured Python library for script-based experiment development, with a high priority being the readability of the resulting program code. Expyriment has been tested extensively under Linux and Windows and is an all-in-one solution, as it handles stimulus presentation, the recording of input/output events, communication with other devices, and the collection and preprocessing of data. Furthermore, it offers a hierarchical design structure, which allows for an intuitive transition from the experimental design to a running program. It is therefore also suited for students, as well as for experimental psychologists and neuroscientists with little programming experience.

  7. Issues central to a useful image understanding environment

    NASA Astrophysics Data System (ADS)

    Beveridge, J. Ross; Draper, Bruce A.; Hanson, Allen R.; Riseman, Edward M.

    1992-04-01

    A recent DARPA initiative has sparked interested in software environments for computer vision. The goal is a single environment to support both basic research and technology transfer. This paper lays out six fundamental attributes such a system must possess: (1) support for both C and Lisp, (2) extensibility, (3) data sharing, (4) data query facilities tailored to vision, (5) graphics, and (6) code sharing. The first three attributes fundamentally constrain the system design. Support for both C and Lisp demands some form of database or data-store for passing data between languages. Extensibility demands that system support facilities, such as spatial retrieval of data, be readily extended to new user-defined datatypes. Finally, data sharing demands that data saved by one user, including data of a user-defined type, must be readable by another user.

  8. Performance enhancement of optical code-division multiple-access systems using transposed modified Walsh code

    NASA Astrophysics Data System (ADS)

    Sikder, Somali; Ghosh, Shila

    2018-02-01

    This paper presents the construction of unipolar transposed modified Walsh code (TMWC) and analysis of its performance in optical code-division multiple-access (OCDMA) systems. Specifically, the signal-to-noise ratio, bit error rate (BER), cardinality, and spectral efficiency were investigated. The theoretical analysis demonstrated that the wavelength-hopping time-spreading system using TMWC was robust against multiple-access interference and more spectrally efficient than systems using other existing OCDMA codes. In particular, the spectral efficiency was calculated to be 1.0370 when TMWC of weight 3 was employed. The BER and eye pattern for the designed TMWC were also successfully obtained using OptiSystem simulation software. The results indicate that the proposed code design is promising for enhancing network capacity.

  9. The Varied Uses of Readability Measurement.

    ERIC Educational Resources Information Center

    Fry, Edward

    Readability formulas have varied uses. In education they are used to match children's reading ability to the difficulty level of material, select stories and books for classroom use and for individual students' particular needs, select textbooks and other reading materials, aid educational research, and check reading materials of newly literate…

  10. An Analysis of the Readability of Financial Accounting Textbooks.

    ERIC Educational Resources Information Center

    Smith, Gerald; And Others

    1981-01-01

    The Flesch formula was used to calculate the readability of 15 financial accounting textbooks. The 15 textbooks represented introductory, intermediate, and advanced levels and also were classified by five different publishers. Two-way analysis of variance and Tukey's post hoc analysis revealed some significant differences. (Author/CT)

  11. Readability of Directions on Potentially Hazardous Household Products

    ERIC Educational Resources Information Center

    Pyrczak, Fred

    1976-01-01

    The study focused on an analysis of the readability of directions on harmful household products. High school students' reading ability was tested using eight sets of sample directions. The results of the study indicate a need for improving the students' ability to read directions on such products. (EC)

  12. Item Readability and Science Achievement in TIMSS 2003 in South Africa

    ERIC Educational Resources Information Center

    Dempster, Edith R.; Reddy, Vijay

    2007-01-01

    This study investigated the relationship between readability of 73 text-only multiple-choice questions from Trends in International Mathematics and Science Study (TIMSS) 2003 and performance of two groups of South African learners: those with limited English-language proficiency (learners attending African schools) and those with better…

  13. Readability of Informed Consent Documents at University Counseling Centers

    ERIC Educational Resources Information Center

    Lustgarten, Samuel D.; Elchert, Daniel M.; Cederberg, Charles; Garrison, Yunkyoung L.; Ho, Y. C. S.

    2017-01-01

    The extent to which clients understand the nature and anticipated course of therapy is referred to as informed consent. Counseling psychologists often provide informed consent documents to enhance the education of services and for liability purposes. Professionals in numerous health care settings have evaluated the readability of their informed…

  14. How Readable Are Parenting Books?

    ERIC Educational Resources Information Center

    Abram, Marie J.; Dowling, William D.

    1979-01-01

    The author's style of writing has implications for the ease with which the written material can be read. Using the Flesch Reading Ease Formula, the mean readability score, the standard deviation, and range are given for 50 parenting books. Discussion suggests how the list might be used by parent educators. (Author)

  15. 17 CFR 1.31 - Books and records; keeping and inspection.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., easily readable projection or production of micrographic media or electronic storage media images; (ii... keep such records, any easily readable hard-copy image that representatives of the Commission or... such records, copies of such records on such compatible data processing media as defined in § 15.00(d...

  16. 17 CFR 1.31 - Books and records; keeping and inspection.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., easily readable projection or production of micrographic media or electronic storage media images; (ii... keep such records, any easily readable hard-copy image that representatives of the Commission or... such records, copies of such records on such compatible data processing media as defined in § 15.00(d...

  17. Factors Influencing the Readability of Student-Generated Texts.

    ERIC Educational Resources Information Center

    Allen, JoBeth

    An investigation examined student-generated texts in terms of both traditional and more theoretically valid readability to determine what factors influence comprehension when children read their own, peer, and adult-written texts. Seventy dictated stories created in an earlier study, along with 4 first-grade level stories from the "Reader's…

  18. A Readability Analysis of Selected Introductory Economics.

    ERIC Educational Resources Information Center

    Gallagher, Daniel J.; Thompson, G. Rodney

    1981-01-01

    To aid secondary school and college level economics teachers as they select textbooks for introductory economics courses, this article recounts how teachers can use the Flesch Reading Ease Test to measure readability. Data are presented on application of the Flesch Reading Ease Test to 15 introductory economics textbooks. (Author/DB)

  19. BLS Machine-Readable Data and Tabulating Routines.

    ERIC Educational Resources Information Center

    DiFillipo, Tony

    This report describes the machine-readable data and tabulating routines that the Bureau of Labor Statistics (BLS) is prepared to distribute. An introduction discusses the LABSTAT (Labor Statistics) database and the BLS policy on release of unpublished data. Descriptions summarizing data stored in 25 files follow this format: overview, data…

  20. Readability Analyses of Selected Vocational Texts. Teaching Basic Skills through Vocational Education. Technical Report.

    ERIC Educational Resources Information Center

    Dunn, James A.; And Others

    This report provides vocational teachers with readability information for selected vocational texts. Selected texts are categorized and appear in charts according to 21 vocational programs: accounting, air conditioning and refrigeration, automotive shop (automotive body and fender repair, automotive mechanics), aviation shop, business, carpentry,…

  1. Tools for Assessing Readability of Statistics Teaching Materials

    ERIC Educational Resources Information Center

    Lesser, Lawrence; Wagler, Amy

    2016-01-01

    This article provides tools and rationale for instructors in math and science to make their assessment and curriculum materials (more) readable for students. The tools discussed (MSWord, LexTutor, Coh-Metrix TEA) are readily available linguistic analysis applications that are grounded in current linguistic theory, but present output that can…

  2. Testing a Readable Writing Approach to Text Revision.

    ERIC Educational Resources Information Center

    Duffy, Thomas M.; Kabance, Paula

    1982-01-01

    The present findings imply that a readability formula is not an effective writing production criterion, even when the writer does not deliberately write to the formula. Comprehensibility of text might be better controlled through the proper use of the transformer concept (MacDonald-Ross and Waller). (Author/PN)

  3. Readability of alphanumeric characters having various contrast levels as a function of age and illumination mode.

    DOT National Transportation Integrated Search

    1977-07-01

    Readability data of alphanumeric characters that vary in figure-to- ground contrast ratio were obtained from 36 subjects; 12 subjects were placed in each of three age groups (20-25 yr, 40-45 yr, and 60-65 yr). Minimum illuminance required to identify...

  4. The SEER Readability Technique: How Practicable is It?

    ERIC Educational Resources Information Center

    Duffelmeyer, Frederick A.

    1982-01-01

    Evaluates the practicability of the Singer Eyeball Estimate of Readability (SEER) techniques with 32 college students. Reveals that only two of the students met SEER's criterion for being considered acceptable judges. Concludes that the criterion is overly stringent and proposes a revised criterion designed to make the SEER technique more…

  5. Documentation for the machine-readable version of the AGK3 Star Catalogue of Positions and Proper Motions North of -2 deg .5 declination (Dieckvoss and Collaborators 1975)

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1984-01-01

    A detailed description of the machine-readable astronomical catalog as it is currently being distributed from the Astronomical Data Center is given. Stellar motions and positions are listed herein in tabular form.

  6. Unreadable and Underreported: Can College Students Comprehend How to Report Sexual Assault?

    ERIC Educational Resources Information Center

    Taylor, Zachary W.

    2018-01-01

    Longitudinal research has suggested that sexual assault on college campuses is widespread and grossly underreported. To date, scholars have not examined a seemingly commonsense aspect of sexual assault reporting: the readability of the reporting instructions themselves; therefore, in this study the author examined the readability--using four…

  7. 10Gbps 2D MGC OCDMA Code over FSO Communication System

    NASA Astrophysics Data System (ADS)

    Professor Urmila Bhanja, Associate, Dr.; Khuntia, Arpita; Alamasety Swati, (Student

    2017-08-01

    Currently, wide bandwidth signal dissemination along with low latency is a leading requisite in various applications. Free space optical wireless communication has introduced as a realistic technology for bridging the gap in present high data transmission fiber connectivity and as a provisional backbone for rapidly deployable wireless communication infrastructure. The manuscript highlights on the implementation of 10Gbps SAC-OCDMA FSO communications using modified two dimensional Golomb code (2D MGC) that possesses better auto correlation, minimum cross correlation and high cardinality. A comparison based on pseudo orthogonal (PSO) matrix code and modified two dimensional Golomb code (2D MGC) is developed in the proposed SAC OCDMA-FSO communication module taking different parameters into account. The simulative outcome signifies that the communication radius is bounded by the multiple access interference (MAI). In this work, a comparison is made in terms of bit error rate (BER), and quality factor (Q) based on modified two dimensional Golomb code (2D MGC) and PSO matrix code. It is observed that the 2D MGC yields better results compared to the PSO matrix code. The simulation results are validated using optisystem version 14.

  8. Readability of Orthopaedic Patient-reported Outcome Measures: Is There a Fundamental Failure to Communicate?

    PubMed

    Perez, Jorge L; Mosher, Zachary A; Watson, Shawna L; Sheppard, Evan D; Brabston, Eugene W; McGwin, Gerald; Ponce, Brent A

    2017-08-01

    Patient-reported outcome measures (PROMs) are increasingly used to quantify patients' perceptions of functional ability. The American Medical Association and NIH suggest patient materials be written at or below 6th to 8th grade reading levels, respectively, yet one recent study asserts that few PROMs comply with these recommendations, and suggests that the majority of PROMs are written at too high of a reading level for self-administered patient use. Notably, this study was limited in its use of only one readability algorithm, although there is no commonly accepted, standard readability algorithm for healthcare-related materials. Our study, using multiple readability equations and heeding equal weight to each, hopes to yield a broader, all-encompassing estimate of readability, thereby offering a more accurate assessment of the readability of orthopaedic PROMS. (1) What proportion of orthopaedic-related PROMs and orthopaedic-related portions of the NIH Patient Reported Outcomes Measurement Information System (PROMIS ® ) are written at or below the 6th and 8th grade levels? (2) Is there a correlation between the number of questions in the PROM and reading level? (3) Using systematic edits based on guidelines from the Centers for Medicare and Medicaid Services, what proportion of PROMs achieved American Medical Association and NIH-recommended reading levels? Eighty-six (86) independent, orthopaedic and general wellness PROMs, drawn from commonly referenced orthopaedic websites and prior studies, were chosen for analysis. Additionally, owing to their increasing use in orthopaedics, four relevant short forms, and 11 adult, physical health question banks from the PROMIS ® , were included for analysis. All documents were analyzed for reading grade levels using 19 unique readability algorithms. Descriptive statistics were performed using SPSS Version 22.0. The majority of the independent PROMs (64 of 86; 74%) were written at or below the 6th grade level, with 81 of 86 (94%) written at or below the 8th grade level. All item banks (11 of 11) and short forms (four of four) of the PROMIS ® were written below the 6th grade reading level. The median reading grade level of the 86 independent PROMs was 5.0 (interquartile range [IQR], 4.6-6.1). The PROMIS ® question banks had a median reading grade level of 4.1 (IQR, 3.5-4.8); the Adult Short Forms had a median reading grade level of 4.2 (IQR, 4.2-4.3) There was no correlation appreciated between the median reading grade level and the number of questions contained in a PROM (r = -0.081; p = 0.460). For PROMs above NIH-recommended levels, following edits, all (five of five) achieved NIH reading level goals and three (three of five) achieved American Medical Association goals. Editing of these PROMs improved readability by 4.3 median grade level (before, 8.9 [IQR, 8.4-9.1], after 4.6 [IQR, 4.6-6.4], difference of medians, 4.3; p = 0.008). Patient literacy has great influence on healthcare outcomes, and readability is an important consideration in all patient-directed written materials. Our study found that more than 70% of PROMs commonly used in orthopaedics, and all orthopaedic-related portions of the PROMIS ® are written at or below the most stringent recommendations (≤ 6th grade reading level), and more than 90% of independent PROMs and all PROMIS ® materials are written at or below an 8th grade level. Additionally, the use of the Centers for Medicare and Medicaid Services guidelines for editing high reading level PROMs yields satisfactory results. Fears of widely incomprehensible PROMs may be unfounded. Future research to identify the most appropriate readability algorithm for use in the healthcare sector, and revalidation of PROMs after readability-improving edits is warranted.

  9. Developing and modifying behavioral coding schemes in pediatric psychology: a practical guide.

    PubMed

    Chorney, Jill MacLaren; McMurtry, C Meghan; Chambers, Christine T; Bakeman, Roger

    2015-01-01

    To provide a concise and practical guide to the development, modification, and use of behavioral coding schemes for observational data in pediatric psychology. This article provides a review of relevant literature and experience in developing and refining behavioral coding schemes. A step-by-step guide to developing and/or modifying behavioral coding schemes is provided. Major steps include refining a research question, developing or refining the coding manual, piloting and refining the coding manual, and implementing the coding scheme. Major tasks within each step are discussed, and pediatric psychology examples are provided throughout. Behavioral coding can be a complex and time-intensive process, but the approach is invaluable in allowing researchers to address clinically relevant research questions in ways that would not otherwise be possible. © The Author 2014. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Boltzmann Transport Code Update: Parallelization and Integrated Design Updates

    NASA Technical Reports Server (NTRS)

    Heinbockel, J. H.; Nealy, J. E.; DeAngelis, G.; Feldman, G. A.; Chokshi, S.

    2003-01-01

    The on going efforts at developing a web site for radiation analysis is expected to result in an increased usage of the High Charge and Energy Transport Code HZETRN. It would be nice to be able to do the requested calculations quickly and efficiently. Therefore the question arose, "Could the implementation of parallel processing speed up the calculations required?" To answer this question two modifications of the HZETRN computer code were created. The first modification selected the shield material of Al(2219) , then polyethylene and then Al(2219). The modified Fortran code was labeled 1SSTRN.F. The second modification considered the shield material of CO2 and Martian regolith. This modified Fortran code was labeled MARSTRN.F.

  11. Discriminability measures for predicting readability of text on textured backgrounds

    NASA Technical Reports Server (NTRS)

    Scharff, L. F.; Hill, A. L.; Ahumada, A. J. Jr; Watson, A. B. (Principal Investigator)

    2000-01-01

    Several discriminability measures were examined for their ability to predict reading search times for three levels of text contrast and a range of backgrounds (plain, a periodic texture, and four spatial-frequency-filtered textures created from the periodic texture). Search times indicate that these background variations only affect readability when the text contrast is low, and that spatial frequency content of the background affects readability. These results were not well predicted by the single variables of text contrast (Spearman rank correlation = -0.64) and background RMS contrast (0.08), but a global masking index and a spatial-frequency-selective masking index led to better predictions (-0.84 and -0.81, respectively). c2000 Optical Society of America.

  12. Gray scale enhances display readability of bitmapped documents

    NASA Astrophysics Data System (ADS)

    Ostberg, Olov; Disfors, Dennis; Feng, Yingduo

    1994-05-01

    Bitmapped images of high resolution, say 300 dpi rastered documents, stored in the memory of a PC are at best only borderline readable on the PC's display screen (say a 72 dpi VGA monitor). Results from a series of exploratory psycho-physical experiments, using the Adobe PhotoshopR software, show that the readability can be significantly enhanced by making use of the monitor's capability to display shades of gray. It is suggested that such a gray scale adaptation module should be bundled to all software products for electronic document management. In fact, fax modems are already available in which this principle is employed, hereby making it possible to read incoming fax documents directly on the screen.

  13. MyPyramid.gov: assessment of literacy, cultural and linguistic factors in the USDA food pyramid web site.

    PubMed

    Neuhauser, Linda; Rothschild, Rebeccah; Rodríguez, Fátima M

    2007-01-01

    MyPyramid.gov, a major national Web site about healthful eating and physical activity, was analyzed for literacy, cultural, and linguistic factors relevant to consumers. The assessment used 4 standardized readability tests, 1 navigational test, availability of non-English content, and new criteria for cultural factors. Readability scores averaged between grade levels 8.8 and 10.8, and half the navigation criteria were met. The Web site was available in Spanish, but it had little cultural tailoring for English speakers. It is recommended that MyPyramid's readability, navigation, and cultural tailoring be improved. References are provided to help educators learn more about assessing and using Internet communication with diverse audiences.

  14. Documentation for the machine-readable version of the revised Catalogue of Stellar Rotational Velocities of Uesugi and Fukuda (1982)

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1983-01-01

    The machine-readable catalog provides mean data on the old Slettebak system for 6472 stars. The catalog results from the review, analysis and transformation of 11460 data from 102 sources. Star identification, (major catalog number, name if the star has one, or cluster identification, etc.), a man projected rotational velocity, and a list of source references re included. The references are given in a second file included with the catalog when it is distributed on magnetic tape. The contents and/formats of the the data and reference files of the machine-readable catalog are described to enable users to read and process the data.

  15. Orthodontic informed consent considering information load and serial position effect.

    PubMed

    Pawlak, Caroline E; Fields, Henry W; Beck, F Michael; Firestone, Allen R

    2015-03-01

    Previous research has demonstrated that current methods of informed consent are relatively ineffective as shown by poor recall and comprehension by adolescent patients and their parents. The purpose of this study was to determine whether adding a short videotape presentation reiterating the issues related to informed consent to a modified informed consent document that emphasizes a limited number of core and patient-specific custom "chunks" at the beginning of an informed consent presentation improved the recall and comprehension of the risks, benefits, and alternatives of orthodontic treatment. A second objective was to evaluate the current related data for recommendable practices. Seventy patient-parent pairs were randomly divided into 2 groups. The intervention group (group A) patients and parents together reviewed a customized slide show and a short videotape presentation describing the key risks of orthodontic treatment. Group B followed the same protocol without viewing the videotape. All patients and parents were interviewed independently by research assistants using an established measurement tool with open-ended questions. Interviews were transcribed and scored for the appropriateness of responses using a previously established codebook. Lastly, the patients and parents were given 2 reading literacy tests, 1 related to health and 1 with general content followed by the self-administered demographic and psychological state questionnaires. There were no significant differences between the groups for sociodemographic variables. There were no significant differences between the groups for overall recall and comprehension; recall and comprehension for the domains of treatment, risk, and responsibility; and recall and comprehension for core, general, and custom items. The positional effects were limited in impact. When compared with previous studies, these data further demonstrate the benefit of improved readability and audiovisual supplementation with the addition of "chunking." There is no benefit to adding a short video to the previously established improved readability and audiovisual supplementation. There is a significant benefit of improved readability and audiovisual slide supplementation with the addition of "chunking" over traditional informed consent methods in terms of patient improvement in overall comprehension, treatment recall, and treatment comprehension. The treatment domain is the most affected. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. Development of written information for antiretroviral therapy: comprehension in a Tanzanian population.

    PubMed

    Mwingira, Betty; Dowse, Ros

    2007-06-01

    To design and develop a simple, easily readable patient information leaflet (PIL) for a commonly used antiretroviral (ARV) regimen and to evaluate its readability and acceptability in a Tanzanian population. A PIL incorporating simple text and pictograms was designed for the antiretroviral regimen of stavudine, lamivudine and efavirenz. The PIL was designed according to established good design guidelines, modified during a multi-stage iterative testing process and piloted in a South African Xhosa population. The PIL was made available in both English and Kiswahili. Sixty Tanzanian participants who were not taking ARVs were interviewed. They were asked to read the PIL in the language of their choice and were then asked a series of two-part questions; the first part required participants to locate the information in the PIL, after which they were asked to explain the information in their own words. Acceptability was assessed through close-ended questions and open-ended feedback. The influence of selected patient characteristics on comprehension of the PIL was investigated using one-way ANOVA and t-tests for independent samples with a significance level set at 0.05. Comprehension of the written information in an overall percentage understanding. The overall average percentage comprehension of the PIL was 95%. The target set by the EC guideline that at least 80% of participants correctly locate and understand the information was achieved for 19 of the 20 questions. Five of the six instructions illustrated by pictograms were correctly understood by all participants. The only patient characteristics significantly associated with comprehension were educational level and self-reported ease of reading the PIL. Acceptability of the PIL was high and positive comments were associated with simplicity, good design, easy readability and user-friendliness, the latter enhanced by the inclusion of pictograms. The PIL designed for this study was shown to be effective in communicating information about ARVs. Patient characteristics must be taken into account when developing written information, and the final document must be tested for comprehension in the target population.

  17. THE READABILITY OF SCIENCE TEXTBOOKS FOR ELEMENTARY SCHOOL.

    ERIC Educational Resources Information Center

    NEWPORT, JOHN F.

    AN INVESTIGATION WAS MADE OF THE READABILITY LEVELS OF NINE CONTINUOUS SERIES OF ELEMENTARY SCHOOL SCIENCE TEXTBOOKS, GRADES 1-6. THE FOLLOWING SCIENCE SERIES WERE EVALUATED--ALLYN AND BACON, AMERICAN BOOK COMPANY, GINN, HARPER AND ROW, HEATH, LYONS AND CARNAHAN, MACMILLAN, SINGER, AND WINSTON. THE SPACHE FORMULA (SAFIER METHOD) WAS APPLIED TO…

  18. Readability of Igbo Language Textbook in Use in Nigerian Secondary Schools

    ERIC Educational Resources Information Center

    Eze, Nneka Justina

    2015-01-01

    This study assessed the readability of Igbo language textbook in use in Nigerian secondary schools. Five Igbo Language textbook were evaluated. The study employed an evaluation research design. The study was conducted in South Eastern Geopolitical zone of Nigeria which is predominantly the Igbo tribe of Nigeria. Four hundred secondary school…

  19. Why Organizations Continue to Create Patient Information Leaflets with Readability and Usability Problems: An Exploratory Study

    ERIC Educational Resources Information Center

    Gal, Iddo; Prigat, Ayelet

    2005-01-01

    Readability and usability problems with patient information leaflets continue to be reported despite long-standing recognition of their existence and the availability of guidelines for developing health education materials. This exploratory study examined possible causes for such problems, based on interviews with professionals who developed…

  20. Readability of Early Intervention Program Literature

    ERIC Educational Resources Information Center

    Pizur-Barnekow, Kris; Patrick, Timothy; Rhyner, Paula M.; Cashin, Susan; Rentmeester, Angela

    2011-01-01

    Accessibility of early intervention program literature was examined through readability analysis of documents given to families who have a child served by the Birth to 3 program. Nine agencies that serve families in Birth to 3 programs located in a county in the Midwest provided the (n = 94) documents. Documents were included in the analysis if…

  1. Toward the Development of a Model to Estimate the Readability of Credentialing-Examination Materials

    ERIC Educational Resources Information Center

    Badgett, Barbara A.

    2010-01-01

    The purpose of this study was to develop a set of procedures to establish readability, including an equation, that accommodates the multiple-choice item format and occupational-specific language related to credentialing examinations. The procedures and equation should be appropriate for learning materials, examination materials, and occupational…

  2. Reconstructing Readability: Recent Developments and Recommendations in the Analysis of Text Difficulty

    ERIC Educational Resources Information Center

    Benjamin, Rebekah George

    2012-01-01

    Largely due to technological advances, methods for analyzing readability have increased significantly in recent years. While past researchers designed hundreds of formulas to estimate the difficulty of texts for readers, controversy has surrounded their use for decades, with criticism stemming largely from their application in creating new texts…

  3. Validation Study of Waray Text Readability Instrument

    ERIC Educational Resources Information Center

    Oyzon, Voltaire Q.; Corrales, Juven B.; Estardo, Wilfredo M., Jr.

    2015-01-01

    In 2012 the Leyte Normal University developed a computer software--modelled after the Spache Readability Formula (1953) made for English--made to help rank texts that can is used by teachers or research groups on selecting appropriate reading materials to support the DepEd's MTB-MLE program in Region VIII, in the Philippines. However,…

  4. Are Patient-Administered Attention Deficit Hyperactivity Disorder Scales Suitable for Adults?

    ERIC Educational Resources Information Center

    Rogers, Edwin S.; Spalding, Steven L.; Eckard, Alexis A.; Wallace, Lorraine S.

    2009-01-01

    Objective: This primary purpose of this study was to examine cognitive complexity and readability of patient-administered ADHD scales. The secondary purpose was to estimate variation in readability of individual ADHD scale items. Method: Using comprehensive search strategies, we identified eight English-language ADHD scales for inclusion in our…

  5. Research Translation Strategies to Improve the Readability of Workplace Health Promotion Resources

    ERIC Educational Resources Information Center

    Wallace, Alison; Joss, Nerida

    2016-01-01

    Without deliberate and resourced translation, research evidence is unlikely to inform policy and practice. This paper describes the processes and practical solutions used to translate evaluation research findings to improve the readability of print materials in a large scale worksite health programme. It is argued that a knowledge brokering and…

  6. Readability: Theory and Practice.

    ERIC Educational Resources Information Center

    Wells, Barron; Spinks, Nelda

    1991-01-01

    Investigates readability levels of correspondence sent out by Gulf Coast area business offices. Finds that a large majority of the correspondence sent out from the offices under study is written at too high a reading level. Finds also that the greatest problem lies in syllable intensity--the use of "big" words where everyday words would have…

  7. Financial Statistics. Higher Education General Information Survey (HEGIS) [machine-readable data file].

    ERIC Educational Resources Information Center

    Center for Education Statistics (ED/OERI), Washington, DC.

    The Financial Statistics machine-readable data file (MRDF) is a subfile of the larger Higher Education General Information Survey (HEGIS). It contains basic financial statistics for over 3,000 institutions of higher education in the United States and its territories. The data are arranged sequentially by institution, with institutional…

  8. Assessing the Readability of Geoscience Textbooks, Laboratory Manuals, and Supplemental Materials

    ERIC Educational Resources Information Center

    Hippensteel, Scott P.

    2015-01-01

    Reading materials used in undergraduate science classes have not received the same attention in the literature as those used in secondary schools. Additionally, reports critical of college textbooks and their prose are common. To assess both problems and determine the readability of assignments and texts used by geoscience faculty at the…

  9. 45 CFR 205.57 - Maintenance of a machine readable file; requests for income and eligibility information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION-PUBLIC ASSISTANCE PROGRAMS § 205... 45 Public Welfare 2 2012-10-01 2012-10-01 false Maintenance of a machine readable file; requests...

  10. 45 CFR 205.57 - Maintenance of a machine readable file; requests for income and eligibility information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION-PUBLIC ASSISTANCE PROGRAMS § 205... 45 Public Welfare 2 2013-10-01 2012-10-01 true Maintenance of a machine readable file; requests...

  11. 45 CFR 205.57 - Maintenance of a machine readable file; requests for income and eligibility information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION-PUBLIC ASSISTANCE PROGRAMS § 205... 45 Public Welfare 2 2014-10-01 2012-10-01 true Maintenance of a machine readable file; requests...

  12. 45 CFR 205.57 - Maintenance of a machine readable file; requests for income and eligibility information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION-PUBLIC ASSISTANCE PROGRAMS § 205... 45 Public Welfare 2 2011-10-01 2011-10-01 false Maintenance of a machine readable file; requests...

  13. Readability and Reading Ability.

    ERIC Educational Resources Information Center

    Wright, Benjamin D.; Stenner, A. Jackson

    This document discusses the measurement of reading ability and the readability of books by application of the Lexile framework. It begins by stating the importance of uniform measures. It then discusses the history of reading ability testing, based on the assumption that no researcher has been able to measure more than one kind of reading ability.…

  14. Spanish Readability Formulas for Elementary-Level Texts: A Validation Study.

    ERIC Educational Resources Information Center

    Parker, Richard I.; Hasbrouck, Jan E.; Weaver, Laurie

    2001-01-01

    Uses two formulas developed for Spanish language text to analyze 9 stories that were read by 36 Spanish-speaking second graders with limited English proficiency. Finds that the Spanish readability formulas only weakly predicted student performance, indicating the need to pursue broader, qualitative indices of difficulty for Spanish text. (SG)

  15. Predicting the Readability of FORTRAN Programs.

    ERIC Educational Resources Information Center

    Domangue, J. C.; Karbowski, S. A.

    This paper reports the results of two studies of the readability of FORTRAN programs, i.e., the ease with which a programmer can read and analyze programs already written, particularly in the processes of maintenance and debugging. In the first study, low-level characteristics of 202 FORTRAN programs stored on the general-use UNIX systems at Bell…

  16. Readability Levels of Health-Based Websites: From Content to Comprehension

    ERIC Educational Resources Information Center

    Schutten, Mary; McFarland, Allison

    2009-01-01

    Three of the national health education standards include decision-making, accessing information and analyzing influences. WebQuests are a popular inquiry-oriented method used by secondary teachers to help students achieve these content standards. While WebQuests support higher level thinking skills, the readability level of the information on the…

  17. Elementary and Secondary School Civil Rights Survey, 1984 [machine-readable data file].

    ERIC Educational Resources Information Center

    DBS Corp., Arlington, VA.

    The "Elementary and Secondary School Civil Rights Survey" machine-readable data file (MRDF) contains data on the characteristics of student populations enrolled in public schools throughout the United States. The emphasis is on data by race/ethnicity and sex in the following areas: stereotyping in courses, special education, vocational education,…

  18. Choosing the Future: College Students' Projections of Their Personal Life Patterns [machine-readable data file].

    ERIC Educational Resources Information Center

    Thomas, Joan

    "Choosing the Future: College Students' Projections of Their Personal Life Patterns" is a machine-readable data file (MRDF) prepared by the principal investigator in connection with her doctoral program studies and her 1986 unpublished doctoral dissertation prepared in the Department of Psychology at the University of Cincinnati. The…

  19. A Text Readability Continuum for Postsecondary Readiness

    ERIC Educational Resources Information Center

    Williamson, Gary L.

    2008-01-01

    Students who successfully exit high school may nevertheless be unprepared for postsecondary endeavors. Some point to a lack of basic skills attained in the public schools. However, no one has systematically compared the text demands of high school with those of the postsecondary world. If there is a gap in text readability then apparent student…

  20. The Language of Fifty Commonly Used Forms.

    ERIC Educational Resources Information Center

    Abbass, Mazin

    The study analyzes, for readability and difficulty, the language of 50 commonly used application forms. The forms were compared with respect to length, readability, t-unit density, and word-length variables. Forms were also compared against two word-frequency lists. Results show that many of the words appearing often on forms do not appear on the…

  1. Measuring the Readability of Children's Trade Books.

    ERIC Educational Resources Information Center

    Popp, Helen M.; Porter, Douglas

    In order to utilize interesting children's trade books in a systematic reading program, two readability formulas were devised based on a selection of children's trade books. Children's scores on selections from these books and judges' rankings were compared. The judges' decisions were considered to be highly credible and were used as the criterion…

  2. COM: Decisions and Applications in a Small University Library.

    ERIC Educational Resources Information Center

    Schwarz, Philip J.

    Computer-output microfilm (COM) is used at the University of Wisconsin-Stout Library to generate reports from its major machine readable data bases. Conditions indicating the need to convert to COM include existence of a machine readable data base and high cost of report production. Advantages and disadvantages must also be considered before…

  3. Documentation for the machine-readable version of the Lowell Proper Motion Survey northern hemisphere, the G numbered stars

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1982-01-01

    Observed positions, proper motions, estimated photographic magnitudes and colors, and references to identifications in other catalogs are included. Photoelectric data on the UBV system are included for many stars, but no attempt was made to find all existing photometry. The machine-readable catalog is described.

  4. Reference Manual for Machine-Readable Descriptions of Research Projects and Institutions.

    ERIC Educational Resources Information Center

    Dierickx, Harold; Hopkinson, Alan

    This reference manual presents a standardized communication format for the exchange between databases or other information services of machine-readable information on research in progress. The manual is produced in loose-leaf format to facilitate updating. Its first section defines in broad outline the format and content of applicable records. A…

  5. Quality and readability of online information resources on insomnia.

    PubMed

    Ma, Yan; Yang, Albert C; Duan, Ying; Dong, Ming; Yeung, Albert S

    2017-09-01

    The internet is a major source for health information. An increasing number of people, including patients with insomnia, search for remedies online; however, little is known about the quality of such information. This study aimed to evaluate the quality and readability of insomnia-related online information. Google was used as the search engine, and the top websites on insomnia that met the inclusion criteria were evaluated for quality and readability. The analyzed websites belonged to nonprofit, commercial, or academic organizations and institutions such as hospitals and universities. Insomnia-related websites typically included definitions (85%), causes and risk factors (100%), symptoms (95%), and treatment options (90%). Cognitive behavioral therapy for insomnia (CBT-I) was the most commonly recommended approach for insomnia treatment, and sleep drugs are frequently mentioned. The overall quality of the websites on insomnia is moderate, but all the content exceeded the recommended reading ease levels. Concerns that must be addressed to increase the quality and trustworthiness of online health information include sharing metadata, such as authorship, time of creation and last update, and conflicts of interest; providing evidence for reliability; and increasing the readability for a layman audience.

  6. Readability assessment of online urology patient education materials.

    PubMed

    Colaco, Marc; Svider, Peter F; Agarwal, Nitin; Eloy, Jean Anderson; Jackson, Imani M

    2013-03-01

    The National Institutes of Health, American Medical Association, and United States Department of Health and Human Services recommend that patient education materials be written at a fourth to sixth grade reading level to facilitate comprehension. We examined and compared the readability and difficulty of online patient education materials from the American Urological Association and academic urology departments in the Northeastern United States. We assessed the online patient education materials for difficulty level with 10 commonly used readability assessment tools, including the Flesch Reading Ease Score, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning Frequency of Gobbledygook, New Dale-Chall Test, Coleman-Liau index, New Fog Count, Raygor Readability Estimate, FORCAST test and Fry score. Most patient education materials on the websites of these programs were written at or above the eleventh grade reading level. Urological online patient education materials are written above the recommended reading level. They may need to be simplified to facilitate better patient understanding of urological topics. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Code Development in Coupled PARCS/RELAP5 for Supercritical Water Reactor

    DOE PAGES

    Hu, Po; Wilson, Paul

    2014-01-01

    The new capability is added to the existing coupled code package PARCS/RELAP5, in order to analyze SCWR design under supercritical pressure with the separated water coolant and moderator channels. This expansion is carried out on both codes. In PARCS, modification is focused on extending the water property tables to supercritical pressure, modifying the variable mapping input file and related code module for processing thermal-hydraulic information from separated coolant/moderator channels, and modifying neutronics feedback module to deal with the separated coolant/moderator channels. In RELAP5, modification is focused on incorporating more accurate water properties near SCWR operation/transient pressure and temperature in themore » code. Confirming tests of the modifications is presented and the major analyzing results from the extended codes package are summarized.« less

  8. Evaluating the Quality and Readability of Internet Information on Meningiomas.

    PubMed

    Saeed, Fozia; Anderson, Ian

    2017-01-01

    The Internet is a highly powerful resource for patients and provides an extensive amount of information on medical conditions. It is therefore important that the information accessible is accurate, up to date, and at an appropriate comprehensive level for the general public. This article aims to evaluate the quality of patient information on meningiomas. The term meningioma was searched using the following search engines: Google, Bing, Yahoo, Ask, and AOL. The top 100 meningioma Web sites were analyzed for readability using the Flesch Reading Ease score and the Flesch-Kincaid grade level. The quality of each Web page was assessed with the DISCERN instrument and the Centers for Disease Control and Prevention (CDC) Clear Communication Index (CCI). The quality of information on the Internet on meningiomas is highly variable. The overall mean Flesch Reading Ease score was 43.1 (standard deviation = 13.3) and the mean Flesch-Kincaid grade of all the Web sites was 11.2 (standard deviation = 2.3). This finding suggests that the information is on average difficult to read. Only one Web site was at the recommended seventh-grade level and the remainder were above this grade. Only one third of the Web pages had Health On the Net Code of Conduct or The Information Standard certification and were found to be significantly of higher quality: DISCERN (P = 0.022) and CDC CCI (P = 0.027). More than 50% of the Web sites had significantly poor or average DISCERN scores and only 2 Web sites fulfilled the CDC CCI criteria. It is recommended that clinicians personally research material for their patients to be able to guide them to reliable and accurate Web sites. It is also encouraged to become Health On the Net Code of Conduct/The Information Standard certified because this may indicate information of high quality. In addition, it is also recommended that authors of existing information assess the quality of their online health information against the CDC CCI criteria. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Sense and readability: participant information sheets for research studies.

    PubMed

    Ennis, Liam; Wykes, Til

    2016-02-01

    Informed consent in research is partly achieved through the use of information sheets. There is a perception however that these information sheets are long and complex. The recommended reading level for patient information is grade 6, or 11-12 years old. To investigate whether the readability of participant information sheets has changed over time, whether particular study characteristics are related to poorer readability and whether readability and other study characteristics are related to successful study recruitment. Method: We obtained 522 information sheets from the UK National Institute for Health Research Clinical Research Network: Mental Health portfolio database and study principal investigators. Readability was assessed with the Flesch reading index and the Grade level test. Information sheets increased in length over the study period. The mean grade level across all information sheets was 9.8, or 15-16 years old. A high level of patient involvement was associated with more recruitment success and studies involving pharmaceutical or device interventions were the least successful. The complexity of information sheets had little bearing on successful recruitment. Information sheets are far more complex than the recommended reading level of grade 6 for patient information. The disparity may be exacerbated by an increasing focus on legal content. Researchers would benefit from clear guidance from ethics committees on writing succinctly and accessibly and how to balance the competing legal issues with the ability of participants to understand what a study entails. © The Royal College of Psychiatrists 2016.

  10. Sense and readability: participant information sheets for research studies

    PubMed Central

    Ennis, Liam; Wykes, Til

    2016-01-01

    Background Informed consent in research is partly achieved through the use of information sheets. There is a perception however that these information sheets are long and complex. The recommended reading level for patient information is grade 6, or 11–12 years old. Aims To investigate whether the readability of participant information sheets has changed over time, whether particular study characteristics are related to poorer readability and whether readability and other study characteristics are related to successful study recruitment. Method We obtained 522 information sheets from the UK National Institute for Health Research Clinical Research Network: Mental Health portfolio database and study principal investigators. Readability was assessed with the Flesch reading index and the Grade level test. Results Information sheets increased in length over the study period. The mean grade level across all information sheets was 9.8, or 15–16 years old. A high level of patient involvement was associated with more recruitment success and studies involving pharmaceutical or device interventions were the least successful. The complexity of information sheets had little bearing on successful recruitment. Conclusions Information sheets are far more complex than the recommended reading level of grade 6 for patient information. The disparity may be exacerbated by an increasing focus on legal content. Researchers would benefit from clear guidance from ethics committees on writing succinctly and accessibly and how to balance the competing legal issues with the ability of participants to understand what a study entails. PMID:26382948

  11. Readability of Healthcare Literature for Hepatitis B and C.

    PubMed

    Meillier, Andrew; Patel, Shyam; Al-Osaimi, Abdullah M S

    2015-12-01

    Patients increasingly use the Internet for educational material concerning health and diseases. This information can be utilized to teach the population of hepatitis B and C if properly written at the necessary grade level of the intended patient population. We explored the readability of online resources concerning hepatitis B and C. Google searches were performed for "Hepatitis B" and "Hepatitis C." The Internet resources that were intended for patient education were used with specific exclusions. Articles were taken from 19 and 23 different websites focusing on the symptoms, diagnosis, and treatment of hepatitis B and C, respectively. The articles were analyzed using Readability Studio Professional Edition (Oleander Solutions, Vandalia, OH) using 10 different readability scales. The results were compared and averaged to identify the anticipated academic grade level required to understand the information. The average readability scores of the 10 scales had ranges of 9.7-16.4 for hepatitis B and 9.2-16.4 for hepatitis C. The average academic reading grade level for hepatitis B was 12.6 ± 2.1 and for hepatitis C was 12.7 ± 2.1. There was no significant discrepancy between the hepatitis B and C Internet resource averaged grade levels. The resources accessed by patients are higher than the previously determined necessary grade level for patients to properly understand the intended information. The American Medical Association recommends material should be simplified to grade levels below the sixth grade level to benefit the ideal proportion of the patient population.

  12. Forensic scientists' conclusions: how readable are they for non-scientist report-users?

    PubMed

    Howes, Loene M; Kirkbride, K Paul; Kelty, Sally F; Julian, Roberta; Kemp, Nenagh

    2013-09-10

    Scientists have an ethical responsibility to assist non-scientists to understand their findings and expert opinions before they are used as decision-aids within the criminal justice system. The communication of scientific expert opinion to non-scientist audiences (e.g., police, lawyers, and judges) through expert reports is an important but under-researched issue. Readability statistics were used to assess 111 conclusions from a proficiency test in forensic glass analysis. The conclusions were written using an average of 23 words per sentence, and approximately half of the conclusions were expressed using the active voice. At an average Flesch-Kincaid Grade level of university undergraduate (Grade 13), and Flesch Reading Ease score of difficult (42), the conclusions were written at a level suitable for people with some tertiary education in science, suggesting that the intended non-scientist readers would find them difficult to read. To further analyse the readability of conclusions, descriptive features of text were used: text structure; sentence structure; vocabulary; elaboration; and coherence and unity. Descriptive analysis supported the finding that texts were written at a level difficult for non-scientists to read. Specific aspects of conclusions that may pose difficulties for non-scientists were located. Suggestions are included to assist scientists to write conclusions with increased readability for non-scientist readers, while retaining scientific integrity. In the next stage of research, the readability of expert reports in their entirety is to be explored. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Are we failing to communicate? Internet-based patient education materials and radiation safety.

    PubMed

    Hansberry, David R; Ramchand, Tekchand; Patel, Shyam; Kraus, Carl; Jung, Jin; Agarwal, Nitin; Gonzales, Sharon F; Baker, Stephen R

    2014-09-01

    Patients frequently turn to the Internet when seeking answers to healthcare related inquiries including questions about the effects of radiation when undergoing radiologic studies. We investigate the readability of online patient education materials concerning radiation safety from multiple Internet resources. Patient education material regarding radiation safety was downloaded from 8 different websites encompassing: (1) the Centers for Disease Control and Prevention, (2) the Environmental Protection Agency, (3) the European Society of Radiology, (4) the Food and Drug Administration, (5) the Mayo Clinic, (6) MedlinePlus, (7) the Nuclear Regulatory Commission, and (8) the Society of Pediatric Radiology. From these 8 resources, a total of 45 articles were analyzed for their level of readability using 10 different readability scales. The 45 articles had a level of readability ranging from 9.4 to the 17.2 grade level. Only 3/45 (6.7%) were written below the 10th grade level. No statistical difference was seen between the readability level of the 8 different websites. All 45 articles from all 8 websites failed to meet the recommendations set forth by the National Institutes of Health and American Medical Association that patient education resources be written between the 3rd and 7th grade level. Rewriting the patient education resources on radiation safety from each of these 8 websites would help many consumers of healthcare information adequately comprehend such material. Copyright © 2014. Published by Elsevier Ireland Ltd.

  14. Digitized forensics: retaining a link between physical and digital crime scene traces using QR-codes

    NASA Astrophysics Data System (ADS)

    Hildebrandt, Mario; Kiltz, Stefan; Dittmann, Jana

    2013-03-01

    The digitization of physical traces from crime scenes in forensic investigations in effect creates a digital chain-of-custody and entrains the challenge of creating a link between the two or more representations of the same trace. In order to be forensically sound, especially the two security aspects of integrity and authenticity need to be maintained at all times. Especially the adherence to the authenticity using technical means proves to be a challenge at the boundary between the physical object and its digital representations. In this article we propose a new method of linking physical objects with its digital counterparts using two-dimensional bar codes and additional meta-data accompanying the acquired data for integration in the conventional documentation of collection of items of evidence (bagging and tagging process). Using the exemplary chosen QR-code as particular implementation of a bar code and a model of the forensic process, we also supply a means to integrate our suggested approach into forensically sound proceedings as described by Holder et al.1 We use the example of the digital dactyloscopy as a forensic discipline, where currently progress is being made by digitizing some of the processing steps. We show an exemplary demonstrator of the suggested approach using a smartphone as a mobile device for the verification of the physical trace to extend the chain-of-custody from the physical to the digital domain. Our evaluation of the demonstrator is performed towards the readability and the verification of its contents. We can read the bar code despite its limited size of 42 x 42 mm and rather large amount of embedded data using various devices. Furthermore, the QR-code's error correction features help to recover contents of damaged codes. Subsequently, our appended digital signature allows for detecting malicious manipulations of the embedded data.

  15. Reusability of coded data in the primary care electronic medical record: A dynamic cohort study concerning cancer diagnoses.

    PubMed

    Sollie, Annet; Sijmons, Rolf H; Helsper, Charles; Numans, Mattijs E

    2017-03-01

    To assess quality and reusability of coded cancer diagnoses in routine primary care data. To identify factors that influence data quality and areas for improvement. A dynamic cohort study in a Dutch network database containing 250,000 anonymized electronic medical records (EMRs) from 52 general practices was performed. Coded data from 2000 to 2011 for the three most common cancer types (breast, colon and prostate cancer) was compared to the Netherlands Cancer Registry. Data quality is expressed in Standard Incidence Ratios (SIRs): the ratio between the number of coded cases observed in the primary care network database and the expected number of cases based on the Netherlands Cancer Registry. Ratios were multiplied by 100% for readability. The overall SIR was 91.5% (95%CI 88.5-94.5) and showed improvement over the years. SIRs differ between cancer types: from 71.5% for colon cancer in males to 103.9% for breast cancer. There are differences in data quality (SIRs 76.2% - 99.7%) depending on the EMR system used, with SIRs up to 232.9% for breast cancer. Frequently observed errors in routine healthcare data can be classified as: lack of integrity checks, inaccurate use and/or lack of codes, and lack of EMR system functionality. Re-users of coded routine primary care Electronic Medical Record data should be aware that 30% of cancer cases can be missed. Up to 130% of cancer cases found in the EMR data can be false-positive. The type of EMR system and the type of cancer influence the quality of coded diagnosis registry. While data quality can be improved (e.g. through improving system design and by training EMR system users), re-use should only be taken care of by appropriately trained experts. Copyright © 2016. Published by Elsevier B.V.

  16. Relationships between abstract features and methodological quality explained variations of social media activity derived from systematic reviews about psoriasis interventions.

    PubMed

    Ruano, J; Aguilar-Luque, M; Isla-Tejera, B; Alcalde-Mellado, P; Gay-Mimbrera, J; Hernandez-Romero, José Luis; Sanz-Cabanillas, J L; Maestre-López, B; González-Padilla, M; Carmona-Fernández, P J; Gómez-García, F; García-Nieto, A Vélez

    2018-05-24

    The aim of this study was to describe the relationship among abstract structure, readability, and completeness, and how these features may influence social media activity and bibliometric results, considering systematic reviews (SRs) about interventions in psoriasis classified by methodological quality. Systematic literature searches about psoriasis interventions were undertaken on relevant databases. For each review, methodological quality was evaluated using the Assessing the Methodological Quality of Systematic Reviews (AMSTAR) tool. Abstract extension, structure, readability, and quality and completeness of reporting were analyzed. Social media activity, which consider Twitter and Facebook mention counts, as well as Mendeley readers and Google scholar citations were obtained for each article. Analyses were conducted to describe any potential influence of abstract characteristics on review's social media diffusion. We classified 139 intervention SRs as displaying high/moderate/low methodological quality. We observed that abstract readability of SRs has been maintained high for last 20 years, although there are some differences based on their methodological quality. Free-format abstracts were most sensitive to the increase of text readability as compared with more structured abstracts (IMRAD or 8-headings), yielding opposite effects on their quality and completeness depending on the methodological quality: a worsening in low quality reviews and an improvement in those of high-quality. Both readability indices and PRISMA for Abstract total scores showed an inverse relationship with social media activity and bibliometric results in high methodological quality reviews but not in those of lower quality. Our results suggest that increasing abstract readability must be specially considered when writing free-format summaries of high-quality reviews, because this fact correlates with an improvement of their completeness and quality, and this may help to achieve broader social media visibility and article usage. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Otoplasty Online Information: A Comprehensive Analysis of the Websites and Videos that Patients View Regarding Cosmetic Ear Surgery.

    PubMed

    Nissan, Michael E; Gupta, Amar; Rayess, Hani; Black, Kevin Z; Carron, Michael

    2018-02-01

    Physicians should be aware of both websites and videos available online regarding the otoplasty procedure to provide quality care. This study systematically analyzes the authorships, reliability, quality, and readability of the websites, as well as the authorships and primary objectives of the videos regarding otoplasty. Validated instruments were used to analyze the reliability, quality, and readability of websites, and videos were systematically categorized and analyzed. A Google search was conducted, and the first five pages of results were included in this study. After excluding unrelated websites, the remaining 44 websites were categorized by authorship (physician, patient, academic, or unaffiliated) and were analyzed using the validated DISCERN instrument for reliability and quality, as well as various other validated instruments to measure readability. A YouTube search was also conducted, and the first 50 relevant videos were included in the study. These videos were categorized by authorship and their primary objective. Website authorships were physician-dominated. Reliability, quality, and overall DISCERN score differ between the four authorship groups by a statistically significant margin (Kruskall-Wallis test, p  < 0.05). Unaffiliated websites were the most reliable, and physician websites were the least reliable. Academic websites were of the highest quality, and patient websites were of the lowest quality. Readability did not differ significantly between the groups, though the readability measurements made showed a general lack of material easily readable by the general public. YouTube was likewise dominated by physician-authored videos. While the physician-authored videos sought mainly to inform and to advertise, patient-authored videos sought mainly to provide the patient's perspective. Academic organizations showed very little representation on YouTube, and the YouTube views on otoplasty videos were dominated by the top 20 videos, which represented over 93% of the total views of videos included in this study. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Assessment of readability, quality and popularity of online information on ureteral stents.

    PubMed

    Mozafarpour, Sarah; Norris, Briony; Borin, James; Eisner, Brian H

    2018-02-12

    To evaluate the quality and readability of online information on ureteral stents. Google.com was queried using the search terms "ureteric stent", "ureteral stent", "double J stent" and, "Kidney stent" derived from Google AdWords. Website popularity was determined using Google Rank and the Alexa tool. Website quality assessment was performed using the following criteria: Journal of the American Medical Association (JAMA) benchmarks, Health on the Net (HON) criteria, and a customized DISCERN questionnaire. The customized DISCERN questionnaire was developed by combining the short validated DISCERN questionnaire with additional stent-specific items including definition, placement, complications, limitations, removal and "when to seek help". Scores related to stent items were considered as the "stent score" (SS). Readability was evaluated using five readability tests. Thirty-two websites were included. The mean customized DISCERN score and "stent score" were 27.1 ± 7.1 (maximum possible score = 59) and 14.6 ± 3.8 (maximum possible score = 24), respectively. A minority of websites adequately addressed "stent removal" and "when to seek medical attention". Only two websites (6.3%) had HON certification (drugs.com, radiologyinfo.org) and only one website (3.3%) met all JAMA criteria (bradyurology.blogspot.com). Readability level was higher than the American Medical Association recommendation of sixth-grade level for more than 75% of the websites. There was no correlation between Google rank, Alexa rank, and the quality scores (P > 0.05). Among the 32 most popular websites on the topic of ureteral stents, online information was highly variable. The readability of many of the websites was far higher than standard recommendations and the online information was questionable in many cases. These findings suggest a need for improved online resources in order to better educate patients about ureteral stents and also should inform physicians that popular websites may have incomplete information.

  19. Readability of arthroscopy-related patient education materials from the American Academy of Orthopaedic Surgeons and Arthroscopy Association of North America Web sites.

    PubMed

    Yi, Paul H; Ganta, Abhishek; Hussein, Khalil I; Frank, Rachel M; Jawa, Andrew

    2013-06-01

    We sought to assess the readability levels of arthroscopy-related patient education materials available on the Web sites of the American Academy of Orthopaedic Surgeons (AAOS) and the Arthroscopy Association of North America (AANA). We identified all articles related to arthroscopy available in 2012 from the online patient education libraries of AAOS and AANA. After performing follow-up editing, we assessed each article with the Flesch-Kincaid (FK) readability test. Mean readability levels of the articles from the AAOS Web site and the AANA Web site were compared. We also determined the number of articles with readability levels at or below the eighth-grade level (the average reading ability of the US adult population) and sixth-grade level (the widely recommended level for patient education materials). Intraobserver reliability and interobserver reliability of FK grade assessment were evaluated. A total of 62 articles were reviewed (43 from AAOS and 19 from AANA). The mean overall FK grade level was 10.2 (range, 5.2 to 12). The AAOS articles had a mean FK grade level of 9.6 (range, 5.2 to 12), whereas the AANA articles had a mean FK grade level of 11.4 (range, 8.7 to 12); the difference was significant (P < .0001). Only 3 articles had a readability level at or below the eighth-grade level and only 1 was at or below the sixth-grade level; all were from AAOS. Intraobserver reliability and interobserver reliability were excellent (intraclass correlation coefficient of 1 for both). Online patient education materials related to arthroscopy from AAOS and AANA may be written at a level too difficult for a large portion of the patient population to comprehend. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Monte Carlo tests of the ELIPGRID-PC algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davidson, J.R.

    1995-04-01

    The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID computer code of Singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM{reg_sign} PC. However, no known independent validation of the ELIPGRID algorithm exists. This document describes a Monte Carlo simulation-based validation of a modified version of the ELIPGRID-PC code. The modified ELIPGRID-PC code is shown to match Monte Carlo-calculated hot-spot detection probabilities to within {plus_minus}0.5% for 319 out of 320 test cases. The one exception, a very thin elliptical hot spot located within a rectangularmore » sampling grid, differed from the Monte Carlo-calculated probability by about 1%. These results provide confidence in the ability of the modified ELIPGRID-PC code to accurately predict hot-spot detection probabilities within an acceptable range of error.« less

Top