Hill, Andrew; Kelly, Eliza; Horswill, Mark S; Watson, Marcus O
2018-02-01
To investigate whether awareness of manual respiratory rate monitoring affects respiratory rate in adults, and whether count duration influences respiratory rate estimates. Nursing textbooks typically suggest that the patient should ideally be unaware of respiratory rate observations; however, there is little published evidence of the effect of awareness on respiratory rate, and none specific to manual measurement. In addition, recommendations about the length of the respiratory rate count vary from text to text, and the relevant empirical evidence is scant, inconsistent and subject to substantial methodological limitations. Experimental study with awareness of respiration monitoring (aware, unaware; randomised between-subjects) and count duration (60 s, 30 s, 15 s; within-subjects) as the independent variables. Respiratory rate (breaths/minute) was the dependent variable. Eighty-two adult volunteers were randomly assigned to aware and unaware conditions. In the baseline block, no live monitoring occurred. In the subsequent experimental block, the researcher informed aware participants that their respiratory rate would be counted, and did so. Respirations were captured throughout via video recording, and counted by blind raters viewing 60-, 30- and 15-s extracts. The data were collected in 2015. There was no baseline difference between the groups. During the experimental block, the respiratory rates of participants in the aware condition were an average of 2.13 breaths/minute lower compared to unaware participants. Reducing the count duration from 1 min to 15 s caused respiratory rate to be underestimated by an average of 2.19 breaths/minute (and 0.95 breaths/minute for 30-s counts). The awareness effect did not depend on count duration. Awareness of monitoring appears to reduce respiratory rate, and shorter monitoring durations yield systematically lower respiratory rate estimates. When interpreting and acting upon respiratory rate data, clinicians should consider the potential influence of these factors, including cumulative effects. © 2017 The Authors. Journal of Clinical Nursing Published by John Wiley & Sons Ltd.
Silva, H G; Lopes, I
Heliospheric modulation of galactic cosmic rays links solar cycle activity with neutron monitor count rate on earth. A less direct relation holds between neutron monitor count rate and atmospheric electric field because different atmospheric processes, including fluctuations in the ionosphere, are involved. Although a full quantitative model is still lacking, this link is supported by solid statistical evidence. Thus, a connection between the solar cycle activity and atmospheric electric field is expected. To gain a deeper insight into these relations, sunspot area (NOAA, USA), neutron monitor count rate (Climax, Colorado, USA), and atmospheric electric field (Lisbon, Portugal) are presented here in a phase space representation. The period considered covers two solar cycles (21, 22) and extends from 1978 to 1990. Two solar maxima were observed in this dataset, one in 1979 and another in 1989, as well as one solar minimum in 1986. Two main observations of the present study were: (1) similar short-term topological features of the phase space representations of the three variables, (2) a long-term phase space radius synchronization between the solar cycle activity, neutron monitor count rate, and potential gradient (confirmed by absolute correlation values above ~0.8). Finally, the methodology proposed here can be used for obtaining the relations between other atmospheric parameters (e.g., solar radiation) and solar cycle activity.
Neutronic analysis of the 1D and 1E banks reflux detection system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blanchard, A.
1999-12-21
Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely,more » the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal {sup 235}U concentration levels to reflux levels remain satisfactory detectable.« less
Pneumotachometer counts respiration rate of human subject
NASA Technical Reports Server (NTRS)
Graham, O.
1964-01-01
To monitor breaths per minute, two rate-to-analog converters are alternately used to read and count the respiratory rate from an impedance pneumograph sequentially displayed numerically on electroluminescent matrices.
NASA Technical Reports Server (NTRS)
Ryu, J. Y.; Wada, M.
1985-01-01
In order to examine the stability of neutron monitor observation, each of the monthly average counting rates of a neutron monitors is correlated to those of Kiel neutron monitor. The regression coefficients thus obtained are compared with the coupling coefficients of isotropic intensity radiation. The results of the comparisons for five year periods during 1963 to 1982, and for whole period are given. The variation spectrum with a single power law with an exponent of -0.75 up to 50 GV is not so unsatisfactory one. More than one half of the stations show correlations with the coefficient greater than 0.9. Some stations have shifted the level of mean counting rates by changing the instrumental characteristics which can be adjusted.
A real-time phoneme counting algorithm and application for speech rate monitoring.
Aharonson, Vered; Aharonson, Eran; Raichlin-Levi, Katia; Sotzianu, Aviv; Amir, Ofer; Ovadia-Blechman, Zehava
2017-03-01
Adults who stutter can learn to control and improve their speech fluency by modifying their speaking rate. Existing speech therapy technologies can assist this practice by monitoring speaking rate and providing feedback to the patient, but cannot provide an accurate, quantitative measurement of speaking rate. Moreover, most technologies are too complex and costly to be used for home practice. We developed an algorithm and a smartphone application that monitor a patient's speaking rate in real time and provide user-friendly feedback to both patient and therapist. Our speaking rate computation is performed by a phoneme counting algorithm which implements spectral transition measure extraction to estimate phoneme boundaries. The algorithm is implemented in real time in a mobile application that presents its results in a user-friendly interface. The application incorporates two modes: one provides the patient with visual feedback of his/her speech rate for self-practice and another provides the speech therapist with recordings, speech rate analysis and tools to manage the patient's practice. The algorithm's phoneme counting accuracy was validated on ten healthy subjects who read a paragraph at slow, normal and fast paces, and was compared to manual counting of speech experts. Test-retest and intra-counter reliability were assessed. Preliminary results indicate differences of -4% to 11% between automatic and human phoneme counting. Differences were largest for slow speech. The application can thus provide reliable, user-friendly, real-time feedback for speaking rate control practice. Copyright © 2017 Elsevier Inc. All rights reserved.
Han, Haihong; Li, Ning; Li, Yepeng; Fu, Ping; Yu, Dongmin; Li Zhigang; Du, Chunming; Guo, Yunchang
2015-01-01
To test the aerobic plate count examining capability of microbiology laboratories, to ensure the accuracy and comparability of quantitative bacteria examination results, and to improve the quality of monitoring. The 4 different concentration aerobic plate count piece samples were prepared and noted as I, II, III and IV. After homogeneity and stability tests, the samples were delivered to monitoring institutions. The results of I, II, III samples were logarithmic transformed, and evaluated with Z-score method using the robust average and standard deviation. The results of IV samples were evaluated as "satisfactory" when reported as < 10 CFU/piece or as "not satisfactory" otherwise. Pearson χ2 test was used to analyze the ratio results. 309 monitoring institutions, which was 99.04% of the total number, reported their results. 271 institutions reported a satisfactory result, and the satisfactory rate was 87.70%. There was no statistical difference in satisfactory rates of I, II and III samples which were 81.52%, 88.30% and 91.40% respectively. The satisfactory rate of IV samples was 93.33%. There was no statistical difference in satisfactory rates between provincial and municipal CDC. The quality control program has provided scientific data that the aerobic plate count capability of the laboratories meets the requirements of monitoring tasks.
NASA Astrophysics Data System (ADS)
Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo
2015-04-01
Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.
Extended range radiation dose-rate monitor
Valentine, Kenneth H.
1988-01-01
An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.
Heliospheric Modulation Strength During The Neutron Monitor Era
NASA Astrophysics Data System (ADS)
Usoskin, I. G.; Alanko, K.; Mursula, K.; Kovaltsov, G. A.
Using a stochastic simulation of a one-dimensional heliosphere we calculate galactic cosmic ray spectra at the Earth's orbit for different values of the heliospheric mod- ulation strength. Convoluting these spectra with the specific yield function of a neu- tron monitor, we obtain the expected neutron monitor count rates for different values of the modulation strength. Finally, inverting this relation, we calculate the modula- tion strength using the actually recorded neutron monitor count rates. We present the reconstructed annual heliospheric modulation strengths for the neutron monitor era (19532000) using several neutron monitors from different latitudes, covering a large range of geomagnetic rigidity cutoffs from polar to equatorial regions. The estimated modulation strengths are shown to be in good agreement with the corresponding esti- mates reported earlier for some years.
Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zickefoose, J.; Kulkarni, T.; Martinson, T.
The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - Xmore » and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)« less
NASA Technical Reports Server (NTRS)
Stoker, P. H.
1985-01-01
Recordings on relativistic solar flare protons observed at Sanae, Antarctic, show that the percentage increase in counting rates of the neutron moderated detector (4NMD) is larger than the percentage increase in counting rates of the 3NM64 neutron monitor. These relative increases are described by solar proton differential spectra j sub s(P) = AP(beta). The power beta is determined for each event and the hardnesses of the temporal variations of beta, found for the ground level events (GLE) of 7 May, 1978 and 22 November, 1977.
Grey W. Pendleton
1995-01-01
Many factors affect the use of point counts for monitoring bird populations, including sampling strategies, variation in detection rates, and independence of sample points. The most commonly used sampling plans are stratified sampling, cluster sampling, and systematic sampling. Each of these might be most useful for different objectives or field situations. Variation...
Data-based Considerations in Portal Radiation Monitoring of Cargo Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weier, Dennis R.; O'Brien, Robert F.; Ely, James H.
2004-07-01
Radiation portal monitoring of cargo vehicles often includes a configuration of four-panel monitors that record gamma and neutron counts from vehicles transporting cargo. As vehicles pass the portal monitors, they generate a count profile over time that can be compared to the average panel background counts obtained just prior to the time the vehicle entered the area of the monitors. Pacific Northwest National Laboratory has accumulated considerable data regarding such background radiation and vehicle profiles from portal installations, as well as in experimental settings using known sources and cargos. Several considerations have a bearing on how alarm thresholds are setmore » in order to maintain sensitivity to radioactive sources while also controlling to a manageable level the rate of false or nuisance alarms. False alarms are statistical anomalies while nuisance alarms occur due to the presence of naturally occurring radioactive material (NORM) in cargo, for example, kitty litter. Considerations to be discussed include: • Background radiation suppression due to the shadow shielding from the vehicle. • The impact of the relative placement of the four panels on alarm decision criteria. • Use of plastic scintillators to separate gamma counts into energy windows. • The utility of using ratio criteria for the energy window counts rather than simply using total window counts. • Detection likelihood for these various decision criteria based on computer simulated injections of sources into vehicle profiles.« less
Park, Hye Jung; Lee, Jae-Hyun; Park, Kyung Hee; Kim, Kyu Rang; Han, Mae Ja; Choe, Hosoeng
2016-01-01
Purpose The occurrence of pollen allergy is subject to exposure to pollen, which shows regional and temporal variations. We evaluated the changes in pollen counts and skin positivity rates for 6 years, and explored the correlation between their annual rates of change. Materials and Methods We assessed the number of pollen grains collected in Seoul, and retrospectively reviewed the results of 4442 skin-prick tests conducted at the Severance Hospital Allergy-Asthma Clinic from January 1, 2008 to December 31, 2013. Results For 6 years, the mean monthly total pollen count showed two peaks, one in May and the other in September. Pollen count for grasses also showed the same trend. The pollen counts for trees, grasses, and weeds changed annually, but the changes were not significant. The annual skin positivity rates in response to pollen from grasses and weeds increased significantly over the 6 years. Among trees, the skin positivity rates in response to pollen from walnut, popular, elm, and alder significantly increased over the 6 years. Further, there was a significant correlation between the annual rate of change in pollen count and the rate of change in skin positivity rate for oak and hop Japanese. Conclusion The pollen counts and skin positivity rates should be monitored, as they have changed annually. Oak and hop Japanese, which showed a significant correlation with the annual rate of change in pollen count and the rate of change in skin positivity rate over the 6 years may be considered the major allergens in Korea. PMID:26996572
Park, Hye Jung; Lee, Jae-Hyun; Park, Kyung Hee; Kim, Kyu Rang; Han, Mae Ja; Choe, Hosoeng; Oh, Jae-Won; Hong, Chein-Soo
2016-05-01
The occurrence of pollen allergy is subject to exposure to pollen, which shows regional and temporal variations. We evaluated the changes in pollen counts and skin positivity rates for 6 years, and explored the correlation between their annual rates of change. We assessed the number of pollen grains collected in Seoul, and retrospectively reviewed the results of 4442 skin-prick tests conducted at the Severance Hospital Allergy-Asthma Clinic from January 1, 2008 to December 31, 2013. For 6 years, the mean monthly total pollen count showed two peaks, one in May and the other in September. Pollen count for grasses also showed the same trend. The pollen counts for trees, grasses, and weeds changed annually, but the changes were not significant. The annual skin positivity rates in response to pollen from grasses and weeds increased significantly over the 6 years. Among trees, the skin positivity rates in response to pollen from walnut, popular, elm, and alder significantly increased over the 6 years. Further, there was a significant correlation between the annual rate of change in pollen count and the rate of change in skin positivity rate for oak and hop Japanese. The pollen counts and skin positivity rates should be monitored, as they have changed annually. Oak and hop Japanese, which showed a significant correlation with the annual rate of change in pollen count and the rate of change in skin positivity rate over the 6 years may be considered the major allergens in Korea.
Organic Scintillation Detectors for Spectroscopic Radiation Portal Monitors
NASA Astrophysics Data System (ADS)
Paff, Marc Gerrit
Thousands of radiation portal monitors have been deployed worldwide to detect and deter the smuggling of nuclear and radiological materials that could be used in nefarious acts. Radiation portal monitors are often installed at bottlenecks where large amounts of people or goods must traverse. Examples of use include scanning cargo containers at shipping ports, vehicles at border crossings, and people at high profile functions and events. Traditional radiation portal monitors contain separate detectors for passively measuring neutron and gamma ray count rates. 3He tubes embedded in polyethylene and slabs of plastic scintillators are the most common detector materials used in radiation portal monitors. The radiation portal monitor alarm mechanism relies on measuring radiation count rates above user defined alarm thresholds. These alarm thresholds are set above natural background count rates. Minimizing false alarms caused by natural background and maximizing sensitivity to weakly emitting threat sources must be balanced when setting these alarm thresholds. Current radiation portal monitor designs suffer from frequent nuisance radiation alarms. These radiation nuisance alarms are most frequently caused by shipments of large quantities of naturally occurring radioactive material containing cargo, like kitty litter, as well as by humans who have recently undergone a nuclear medicine procedure, particularly 99mTc treatments. Current radiation portal monitors typically lack spectroscopic capabilities, so nuisance alarms must be screened out in time-intensive secondary inspections with handheld radiation detectors. Radiation portal monitors using organic liquid scintillation detectors were designed, built, and tested. A number of algorithms were developed to perform on-the-fly radionuclide identification of single and combination radiation sources moving past the portal monitor at speeds up to 2.2 m/s. The portal monitor designs were tested extensively with a variety of shielded and unshielded radiation sources, including special nuclear material, at the European Commission Joint Research Centre in Ispra, Italy. Common medical isotopes were measured at the C.S. Mott Children's Hospital and added to the radionuclide identification algorithms.
Reevaluation of pollen quantitation by an automatic pollen counter.
Muradil, Mutarifu; Okamoto, Yoshitaka; Yonekura, Syuji; Chazono, Hideaki; Hisamitsu, Minako; Horiguchi, Shigetoshi; Hanazawa, Toyoyuki; Takahashi, Yukie; Yokota, Kunihiko; Okumura, Satoshi
2010-01-01
Accurate and detailed pollen monitoring is useful for selection of medication and for allergen avoidance in patients with allergic rhinitis. Burkard and Durham pollen samplers are commonly used, but are labor and time intensive. In contrast, automatic pollen counters allow simple real-time pollen counting; however, these instruments have difficulty in distinguishing pollen from small nonpollen airborne particles. Misidentification and underestimation rates for an automatic pollen counter were examined to improve the accuracy of the pollen count. The characteristics of the automatic pollen counter were determined in a chamber study with exposure to cedar pollens or soil grains. The cedar pollen counts were monitored in 2006 and 2007, and compared with those from a Durham sampler. The pollen counts from the automatic counter showed a good correlation (r > 0.7) with those from the Durham sampler when pollen dispersal was high, but a poor correlation (r < 0.5) when pollen dispersal was low. The new correction method, which took into account the misidentification and underestimation, improved this correlation to r > 0.7 during the pollen season. The accuracy of automatic pollen counting can be improved using a correction to include rates of underestimation and misidentification in a particular geographical area.
Effects of lek count protocols on greater sage-grouse population trend estimates
Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.
2016-01-01
Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count frequency also improved precision. These results suggest that the current distribution of count timings available in lek count databases such as that of Wyoming (conducted up to 90 minutes after sunrise) can be used to estimate sage-grouse population trends without reducing precision or accuracy relative to trends from counts conducted within 30 minutes of sunrise. However, only 10% of all Wyoming counts in our sample (1995−2014) were conducted 61−90 minutes after sunrise, and further increasing this percentage may still bias trend estimates because of declining lek attendance.
Heart-rate pulse-shift detector
NASA Technical Reports Server (NTRS)
Anderson, M.
1974-01-01
Detector circuit accurately separates and counts phase-shift pulses over wide range of basic pulse-rate frequency, and also provides reasonable representation of full repetitive EKG waveform. Single telemeter implanted in small animal monitors not only body temperature but also animal movement and heart rate.
Simultaneous Forbush decreases and associated geomagnetic storms during the last three solar cycles
NASA Astrophysics Data System (ADS)
Okpala, K. C.
2013-12-01
Forbush decrease (FD) are observed reduction in galactic cosmic ray (GCR) intensity as measured by ground neutron monitors. FD is associated with increased activity of the sun as reflected in the size of the interplanetary coronal mass ejections passing around the Earth and the corotating regions in the Heliosphere. Since the interplanetary anisotropy evolves itself during a geomagnetic storm in addition to the reconfiguration of external magnetospheric currents, it is expected that changes in transmissivity of cosmic rays of glactic origin will occur during Geomagnetic storms. In this study we examine over one hundred and fifty (150) FD events and associated geomagnetic storms over the last three solar cycles from 1970 to 2003. The negative peaks of the FDs and the Dst coincided for most of the events (~70%). There was good correlation (>0.65) between the FDs and Dst. Fresh evidence of the influence of external magnetospheric currents on the count rates of the neutron monitors stations during periods of Forbush decreases (FDs) is provided. This evidence is observed as sudden increases in the count rates during the main phase of simultaneous FD. The magnitude of the sudden rise in the count rates of Neutron monitors and peak dst correlated well (>0.50) both for high latitude and mid latitude stations.
Pendleton, G.W.; Ralph, C. John; Sauer, John R.; Droege, Sam
1995-01-01
Many factors affect the use of point counts for monitoring bird populations, including sampling strategies, variation in detection rates, and independence of sample points. The most commonly used sampling plans are stratified sampling, cluster sampling, and systematic sampling. Each of these might be most useful for different objectives or field situations. Variation in detection probabilities and lack of independence among sample points can bias estimates and measures of precision. All of these factors should be con-sidered when using point count methods.
Anigstein, Robert; Erdman, Michael C.; Ansari, Armin
2017-01-01
The detonation of a radiological dispersion device or other radiological incidents could result in the dispersion of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure photon radiation from radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for further assessments. Computer simulations and experimental measurements are required for these instruments to be used for assessing intakes of radionuclides. Count rates from calibrated sources of 60Co, 137Cs, and 241Am were measured on three instruments: a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal, a thyroid probe using a 5.08 × 5.08-cm NaI(Tl) crystal, and a portal monitor incorporating two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators. Computer models of the instruments and of the calibration sources were constructed, using engineering drawings and other data provided by the manufacturers. Count rates on the instruments were simulated using the Monte Carlo radiation transport code MCNPX. The computer simulations were within 16% of the measured count rates for all 20 measurements without using empirical radionuclide-dependent scaling factors, as reported by others. The weighted root-mean-square deviations (differences between measured and simulated count rates, added in quadrature and weighted by the variance of the difference) were 10.9% for the survey meter, 4.2% for the thyroid probe, and 0.9% for the portal monitor. These results validate earlier MCNPX models of these instruments that were used to develop calibration factors that enable these instruments to be used for assessing intakes and committed doses from several gamma-emitting radionuclides. PMID:27115229
Anigstein, Robert; Erdman, Michael C; Ansari, Armin
2016-06-01
The detonation of a radiological dispersion device or other radiological incidents could result in the dispersion of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure photon radiation from radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for further assessments. Computer simulations and experimental measurements are required for these instruments to be used for assessing intakes of radionuclides. Count rates from calibrated sources of Co, Cs, and Am were measured on three instruments: a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal, a thyroid probe using a 5.08 × 5.08-cm NaI(Tl) crystal, and a portal monitor incorporating two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators. Computer models of the instruments and of the calibration sources were constructed, using engineering drawings and other data provided by the manufacturers. Count rates on the instruments were simulated using the Monte Carlo radiation transport code MCNPX. The computer simulations were within 16% of the measured count rates for all 20 measurements without using empirical radionuclide-dependent scaling factors, as reported by others. The weighted root-mean-square deviations (differences between measured and simulated count rates, added in quadrature and weighted by the variance of the difference) were 10.9% for the survey meter, 4.2% for the thyroid probe, and 0.9% for the portal monitor. These results validate earlier MCNPX models of these instruments that were used to develop calibration factors that enable these instruments to be used for assessing intakes and committed doses from several gamma-emitting radionuclides.
Liu, Chuanlei; Zhang, Weihua; Ungar, Kurt; Korpach, Ed; White, Brian; Benotto, Mike; Pellerin, Eric
2018-05-07
This work explores the application of Health Canada's Fixed Point Surveillance (FPS) network for cosmic ray monitoring and dose estimation purposes. This network is comprised of RS250 3 inch by 3 inch Sodium Iodide (NaI) spectroscopic dosimeters distributed throughout Canada. The RS250's high channel count rate responds to the electromagnetic and muonic components of cosmic ray shower. These count rates are used to infer cosmic ray doses throughout FPS locations. The derived dose was found to have an accuracy within 6.5% deviation relative to theoretical calculation. The solar cycle effect and meteorologically induced fluctuation can be realistically reflected in the estimated dose. This work may serve as a basis to enable the FPS network to monitor and report both terrestrial and cosmic radiation in quasi-real time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
False CAM alarms from radon fluctuations.
Hayes, Robert
2003-11-01
The root cause of many false continuous air monitor (CAM) alarms is revealed for CAMs that use constant spectral shape assumptions in transuranic (TRU) alpha activity determination algorithms. This paper shows that when atmospheric radon levels continually decrease and bottom out at a minimum level, reduced false TRU count rates are not only expected but measured. Similarly, when the radon levels continually increase to a maximum level, elevated false TRU count rates were measured as predicted. The basis for expecting this dependence on changes in radon levels is discussed.
Physiologic Monitor Alarm Rates at 5 Children's Hospitals.
Schondelmeyer, Amanda C; Brady, Patrick W; Goel, Veena V; Cvach, Maria; Blake, Nancy; Mangeot, Colleen; Bonafide, Christopher P
2018-06-01
Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates. © 2018 Society of Hospital Medicine.
X-ray detection of Nova Del 2013 with Swift
NASA Astrophysics Data System (ADS)
Castro-Tirado, Alberto J.; Martin-Carrillo, Antonio; Hanlon, Lorraine
2013-08-01
Continuous X-ray monitoring by Swift of Nova Del 2013 (see CBET #3628) shows an increase of X-ray emission at the source location compared to previous observations (ATEL #5283, ATEL #5305) during a 3.9 ksec observation at UT 2013-08-22 12:05. With the XRT instrument operating in window timing mode, 744 counts were extracted from a 50 pixel long source region and 324 counts from a similar box for a background region, resulting in a 13-sigma detection with a net count rate of 0.11±0.008 counts/sec.
Recreational use in dispersed public lands measured using social media data and on-site counts.
Fisher, David M; Wood, Spencer A; White, Eric M; Blahna, Dale J; Lange, Sarah; Weinberg, Alex; Tomco, Michael; Lia, Emilia
2018-09-15
Outdoor recreation is one of many important benefits provided by public lands. Data on recreational use are critical for informing management of recreation resources, however, managers often lack actionable information on visitor use for large protected areas that lack controlled access points. The purpose of this study is to explore the potential for social media data (e.g., geotagged images shared on Flickr and trip reports shared on a hiking forum) to provide land managers with useful measures of recreational use to dispersed areas, and to provide lessons learned from comparing several more traditional counting methods. First, we measure daily and monthly visitation rates to individual trails within the Mount Baker-Snoqualmie National Forest (MBSNF) in western Washington. At 15 trailheads, we compare counts of hikers from infrared sensors, timelapse cameras, and manual on-site counts, to counts based on the number of shared geotagged images and trip reports from those locations. Second, we measure visitation rates to each National Forest System (NFS) unit across the US and compare annual measurements derived from the number of geotagged images to estimates from the US Forest Service National Visitor Use Monitoring Program. At both the NFS unit and the individual-trail scales, we found strong correlations between traditional measures of recreational use and measures based on user-generated content shared on the internet. For national forests in every region of the country, correlations between official Forest Service statistics and geotagged images ranged between 55% and 95%. For individual trails within the MBSNF, monthly visitor counts from on-site measurements were strongly correlated with counts from geotagged images (79%) and trip reports (91%). The convenient, cost-efficient and timely nature of collecting and analyzing user-generated data could allow land managers to monitor use over different seasons of the year and at sites and scales never previously monitored, contributing to a more comprehensive understanding of recreational use patterns and values. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Sun, X.; Jester, P. L.; Palm, S. P.; Abshire, J. B.; Spinhime, J. D.; Krainak, M. A.
2006-01-01
Si avalanche photodiode (APD) single photon counting modules (SPCMs) are used in the Geoscience Laser Altimeter System (GLAS) on Ice, Cloud, anti land Elevation Satellite (ICESat), currently in orbit measuring Earth surface elevation and atmosphere backscattering. These SPCMs are used to measure cloud and aerosol backscatterings to the GLAS laser light at 532-nm wavelength with 60-70% quantum efficiencies and up to 15 millions/s maximum count rates. The performance of the SPCMs has been closely monitored since ICESat launch on January 12, 2003. There has been no measurable change in the quantum efficiency, as indicated by the average photon count rates in response to the background light from the sunlit earth. The linearity and the afterpulsing seen from the cloud and surface backscatterings profiles have been the same as those during ground testing. The detector dark count rates monitored while the spacecraft was in the dark side of the globe have increased almost linearly at about 60 counts/s per day due to space radiation damage. The radiation damage appeared to be independent of the device temperature and power states. There was also an abrupt increase in radiation damage during the solar storm in 28-30 October 2003. The observed radiation damage is a factor of two to three lower than the expected and sufficiently low to provide useful atmosphere backscattering measurements through the end of the ICESat mission. To date, these SPCMs have been in orbit for more than three years. The accumulated operating time to date has reached 290 days (7000 hours). These SPCMs have provided unprecedented receiver sensitivity and dynamic range in ICESat atmosphere backscattering measurements.
Wireless, in-vessel neutron monitor for initial core-loading of advanced breeder reactors
NASA Technical Reports Server (NTRS)
Delorenzo, J. T.; Kennedy, E. J.; Blalock, T. V.; Rochelle, J. M.; Chiles, M. M.; Valentine, K. H.
1981-01-01
An experimental wireless, in-vessel neutron monitor was developed to measure the reactivity of an advanced breeder reactor as the core is loaded for the first time to preclude an accidental critically incident. The environment is liquid sodium at a temperature of approx. 220 C, with negligible gamma or neutron radiation. With ultrasonic transmission of neutron data, no fundamental limitation was observed after tests at 230 C for 2000 h. The neutron sensitivity was approx. 1 count/s-nv, and the potential data transmission rate was approx. 10,000 counts/s.
Monte Carlo simulation of the neutron monitor yield function
NASA Astrophysics Data System (ADS)
Mangeard, P.-S.; Ruffolo, D.; Sáiz, A.; Madlee, S.; Nutaro, T.
2016-08-01
Neutron monitors (NMs) are ground-based detectors that measure variations of the Galactic cosmic ray flux at GV range rigidities. Differences in configuration, electronics, surroundings, and location induce systematic effects on the calculation of the yield functions of NMs worldwide. Different estimates of NM yield functions can differ by a factor of 2 or more. In this work, we present new Monte Carlo simulations to calculate NM yield functions and perform an absolute (not relative) comparison with the count rate of the Princess Sirindhorn Neutron Monitor (PSNM) at Doi Inthanon, Thailand, both for the entire monitor and for individual counter tubes. We model the atmosphere using profiles from the Global Data Assimilation System database and the Naval Research Laboratory Mass Spectrometer, Incoherent Scatter Radar Extended model. Using FLUKA software and the detailed geometry of PSNM, we calculated the PSNM yield functions for protons and alpha particles. An agreement better than 9% was achieved between the PSNM observations and the simulated count rate during the solar minimum of December 2009. The systematic effect from the electronic dead time was studied as a function of primary cosmic ray rigidity at the top of the atmosphere up to 1 TV. We show that the effect is not negligible and can reach 35% at high rigidity for a dead time >1 ms. We analyzed the response function of each counter tube at PSNM using its actual dead time, and we provide normalization coefficients between count rates for various tube configurations in the standard NM64 design that are valid to within ˜1% for such stations worldwide.
NASA Astrophysics Data System (ADS)
Granja, Carlos; Polansky, Stepan; Vykydal, Zdenek; Pospisil, Stanislav; Owens, Alan; Kozacek, Zdenek; Mellab, Karim; Simcak, Marek
2016-06-01
The Space Application of Timepix based Radiation Monitor (SATRAM) is a spacecraft platform radiation monitor on board the Proba-V satellite launched in an 820 km altitude low Earth orbit in 2013. The is a technology demonstration payload is based on the Timepix chip equipped with a 300 μm silicon sensor with signal threshold of 8 keV/pixel to low-energy X-rays and all charged particles including minimum ionizing particles. For X-rays the energy working range is 10-30 keV. Event count rates can be up to 106 cnt/(cm2 s) for detailed event-by-event analysis or over 1011 cnt/(cm2 s) for particle-counting only measurements. The single quantum sensitivity (zero-dark current noise level) combined with per-pixel spectrometry and micro-scale pattern recognition analysis of single particle tracks enables the composition (particle type) and spectral characterization (energy loss) of mixed radiation fields to be determined. Timepix's pixel granularity and particle tracking capability also provides directional sensitivity for energetic charged particles. The payload detector response operates in wide dynamic range in terms of absorbed dose starting from single particle doses in the pGy level, particle count rate up to 106-10 /cm2/s and particle energy loss (threshold at 150 eV/μm). The flight model in orbit was successfully commissioned in 2013 and has been sampling the space radiation field in the satellite environment along its orbit at a rate of several frames per minute of varying exposure time. This article describes the design and operation of SATRAM together with an overview of the response and resolving power to the mixed radiation field including summary of the principal data products (dose rate, equivalent dose rate, particle-type count rate). The preliminary evaluation of response of the embedded Timepix detector to space radiation in the satellite environment is presented together with first results in the form of a detailed visualization of the mixed radiation field at the position of the payload and resulting spatial- and time-correlated radiation maps of cumulative dose rate along the satellite orbit.
Remote monitoring and prognosis of fatigue cracking in steel bridges with acoustic emission
NASA Astrophysics Data System (ADS)
Yu, Jianguo Peter; Ziehl, Paul; Pollock, Adrian
2011-04-01
Acoustic emission (AE) monitoring is desirable to nondestructively detect fatigue damage in steel bridges. Investigations of the relationship between AE signals and crack growth behavior are of paramount importance prior to the widespread application of passive piezoelectric sensing for monitoring of fatigue crack propagation in steel bridges. Tests have been performed to detect AE from fatigue cracks in A572G50 steel. Noise induced AE signals were filtered based on friction emission tests, loading pattern, and a combined approach involving Swansong II filters and investigation of waveforms. The filtering methods based on friction emission tests and load pattern are of interest to the field evaluation using sparse datasets. The combined approach is suitable for data filtering and interpretation of actual field tests. The pattern recognition program NOESIS (Envirocoustics) was utilized for the evaluation of AE data quality. AE parameters are associated with crack length, crack growth rate, maximum stress intensity and stress intensity range. It is shown that AE hits, counts, absolute energy, and signal strength are able to provide warnings at the critical cracking level where cracking progresses from stage II (stable propagation) to stage III (unstable propagation which may result in failure). Absolute energy rate and signal strength rate may be better than count rate to assess the remaining fatigue life of inservice steel bridges.
Metals processing control by counting molten metal droplets
Schlienger, Eric; Robertson, Joanna M.; Melgaard, David; Shelmidine, Gregory J.; Van Den Avyle, James A.
2000-01-01
Apparatus and method for controlling metals processing (e.g., ESR) by melting a metal ingot and counting molten metal droplets during melting. An approximate amount of metal in each droplet is determined, and a melt rate is computed therefrom. Impedance of the melting circuit is monitored, such as by calculating by root mean square a voltage and current of the circuit and dividing the calculated current into the calculated voltage. Analysis of the impedance signal is performed to look for a trace characteristic of formation of a molten metal droplet, such as by examining skew rate, curvature, or a higher moment.
Mooney, Robert; Corley, Gavin; Godfrey, Alan; Osborough, Conor; ÓLaighin, Gearóid
2017-01-01
Aims The study aims were to evaluate the validity of two commercially available swimming activity monitors for quantifying temporal and kinematic swimming variables. Methods Ten national level swimmers (5 male, 5 female; 15.3±1.3years; 164.8±12.9cm; 62.4±11.1kg; 425±66 FINA points) completed a set protocol comprising 1,500m of swimming involving all four competitive swimming strokes. Swimmers wore the Finis Swimsense and the Garmin Swim activity monitors throughout. The devices automatically identified stroke type, swim distance, lap time, stroke count, stroke rate, stroke length and average speed. Video recordings were also obtained and used as a criterion measure to evaluate performance. Results A significant positive correlation was found between the monitors and video for the identification of each of the four swim strokes (Garmin: X2 (3) = 31.292, p<0.05; Finis:X2 (3) = 33.004, p<0.05). No significant differences were found for swim distance measurements. Swimming laps performed in the middle of a swimming interval showed no significant difference from the criterion (Garmin: bias -0.065, 95% confidence intervals -3.828–6.920; Finis bias -0.02, 95% confidence intervals -3.095–3.142). However laps performed at the beginning and end of an interval were not as accurately timed. Additionally, a statistical difference was found for stroke count measurements in all but two occasions (p<0.05). These differences affect the accuracy of stroke rate, stroke length and average speed scores reported by the monitors, as all of these are derived from lap times and stroke counts. Conclusions Both monitors were found to operate with a relatively similar performance level and appear suited for recreational use. However, issues with feature detection accuracy may be related to individual variances in stroke technique. It is reasonable to expect that this level of error would increase when the devices are used by recreational swimmers rather than elite swimmers. Further development to improve accuracy of feature detection algorithms, specifically for lap time and stroke count, would also increase their suitability within competitive settings. PMID:28178301
Mooney, Robert; Quinlan, Leo R; Corley, Gavin; Godfrey, Alan; Osborough, Conor; ÓLaighin, Gearóid
2017-01-01
The study aims were to evaluate the validity of two commercially available swimming activity monitors for quantifying temporal and kinematic swimming variables. Ten national level swimmers (5 male, 5 female; 15.3±1.3years; 164.8±12.9cm; 62.4±11.1kg; 425±66 FINA points) completed a set protocol comprising 1,500m of swimming involving all four competitive swimming strokes. Swimmers wore the Finis Swimsense and the Garmin Swim activity monitors throughout. The devices automatically identified stroke type, swim distance, lap time, stroke count, stroke rate, stroke length and average speed. Video recordings were also obtained and used as a criterion measure to evaluate performance. A significant positive correlation was found between the monitors and video for the identification of each of the four swim strokes (Garmin: X2 (3) = 31.292, p<0.05; Finis:X2 (3) = 33.004, p<0.05). No significant differences were found for swim distance measurements. Swimming laps performed in the middle of a swimming interval showed no significant difference from the criterion (Garmin: bias -0.065, 95% confidence intervals -3.828-6.920; Finis bias -0.02, 95% confidence intervals -3.095-3.142). However laps performed at the beginning and end of an interval were not as accurately timed. Additionally, a statistical difference was found for stroke count measurements in all but two occasions (p<0.05). These differences affect the accuracy of stroke rate, stroke length and average speed scores reported by the monitors, as all of these are derived from lap times and stroke counts. Both monitors were found to operate with a relatively similar performance level and appear suited for recreational use. However, issues with feature detection accuracy may be related to individual variances in stroke technique. It is reasonable to expect that this level of error would increase when the devices are used by recreational swimmers rather than elite swimmers. Further development to improve accuracy of feature detection algorithms, specifically for lap time and stroke count, would also increase their suitability within competitive settings.
Neutron monitors and muon detectors for solar modulation studies: 2. ϕ time series
NASA Astrophysics Data System (ADS)
Ghelfi, A.; Maurin, D.; Cheminet, A.; Derome, L.; Hubert, G.; Melot, F.
2017-08-01
The level of solar modulation at different times (related to the solar activity) is a central question of solar and galactic cosmic-ray physics. In the first paper of this series, we have established a correspondence between the uncertainties on ground-based detectors count rates and the parameter ϕ (modulation level in the force-field approximation) reconstructed from these count rates. In this second paper, we detail a procedure to obtain a reference ϕ time series from neutron monitor data. We show that we can have an unbiased and accurate ϕ reconstruction (Δϕ / ϕ ≃ 10 %). We also discuss the potential of Bonner spheres spectrometers and muon detectors to provide ϕ time series. Two by-products of this calculation are updated ϕ values for the cosmic-ray database and a web interface to retrieve and plot ϕ from the 50's to today (http://lpsc.in2p3.fr/crdb).
Murphy, Alistair P; Duffield, Rob; Kellett, Aaron; Reid, Machar
2014-09-01
To investigate the discrepancy between coach and athlete perceptions of internal load and notational analysis of external load in elite junior tennis. Fourteen elite junior tennis players and 6 international coaches were recruited. Ratings of perceived exertion (RPEs) were recorded for individual drills and whole sessions, along with a rating of mental exertion, coach rating of intended session exertion, and athlete heart rate (HR). Furthermore, total stroke count and unforced-error count were notated using video coding after each session, alongside coach and athlete estimations of shots and errors made. Finally, regression analyses explained the variance in the criterion variables of athlete and coach RPE. Repeated-measures analyses of variance and interclass correlation coefficients revealed that coaches significantly (P < .01) underestimated athlete session RPE, with only moderate correlation (r = .59) demonstrated between coach and athlete. However, athlete drill RPE (P = .14; r = .71) and mental exertion (P = .44; r = .68) were comparable and substantially correlated. No significant differences in estimated stroke count were evident between athlete and coach (P = .21), athlete notational analysis (P = .06), or coach notational analysis (P = .49). Coaches estimated significantly greater unforced errors than either athletes or notational analysis (P < .01). Regression analyses found that 54.5% of variance in coach RPE was explained by intended session exertion and coach drill RPE, while drill RPE and peak HR explained 45.3% of the variance in athlete session RPE. Coaches misinterpreted session RPE but not drill RPE, while inaccurately monitoring error counts. Improved understanding of external- and internal-load monitoring may help coach-athlete relationships in individual sports like tennis avoid maladaptive training.
NASA Technical Reports Server (NTRS)
Sakaguchi, T.; Doke, T.; Hayashi, T.; Kikuchi, J.; Hasebe, N.; Kashiwagi, T.; Takashima, T.; Takahashi, K.; Nakano, T.; Nagaoka, S.;
1997-01-01
The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.
Gerry, Alec C; Higginbotham, G E; Periera, L N; Lam, A; Shelton, C R
2011-06-01
Relative house fly, Musca domestica L., activity at three large dairies in central California was monitored during the peak fly activity period from June to August 2005 by using spot cards, fly tapes, bait traps, and Alsynite traps. Counts for all monitoring methods were significantly related at two of three dairies; with spot card counts significantly related to fly tape counts recorded the same week, and both spot card counts and fly tape counts significantly related to bait trap counts 1-2 wk later. Mean fly counts differed significantly between dairies, but a significant interaction between dairies sampled and monitoring methods used demonstrates that between-dairy comparisons are unwise. Estimate precision was determined by the coefficient of variability (CV) (or SE/mean). Using a CV = 0.15 as a desired level of estimate precision and assuming an integrate pest management (IPM) action threshold near the peak house fly activity measured by each monitoring method, house fly monitoring at a large dairy would require 12 spot cards placed in midafternoon shaded fly resting sites near cattle or seven bait traps placed in open areas near cattle. Software (FlySpotter; http://ucanr.org/ sites/FlySpotter/download/) using computer vision technology was developed to count fly spots on a scanned image of a spot card to dramatically reduce time invested in monitoring house flies. Counts provided by the FlySpotter software were highly correlated to visual counts. The use of spot cards for monitoring house flies is recommended for dairy IPM programs.
van den Boogaard, Jossy; Lyimo, Ramsey A; Boeree, Martin J; Kibiki, Gibson S; Aarnoutse, Rob E
2011-09-01
To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one urban hospital and two urban health centres. Treatment adherence was monitored with MEMS and the validity of the following adherence measures was assessed: isoniazid urine test, urine colour test, Morisky scale, Brief Medication Questionnaire, adapted AIDS Clinical Trials Group (ACTG) adherence questionnaire, pill counts and medication refill visits. The mean adherence rate in the study population was 96.3% (standard deviation, SD: 7.7). Adherence was less than 100% in 70% of the patients, less than 95% in 21% of them, and less than 80% in 2%. The ACTG adherence questionnaire and urine colour test had the highest sensitivities but lowest specificities. The Morisky scale and refill visits had the highest specificities but lowest sensitivities. Pill counts and refill visits combined, used in routine practice, yielded moderate sensitivity and specificity, but sensitivity improved when the ACTG adherence questionnaire was added. Patients on community-based DOT showed good adherence in this study. The combination of pill counts, refill visits and the ACTG adherence questionnaire could be used to monitor adherence in settings where MEMS is not affordable. The findings with regard to adherence and to the validity of simple adherence measures should be confirmed in larger populations with wider variability in adherence rates.
Power monitoring in space nuclear reactors using silicon carbide radiation detectors
NASA Technical Reports Server (NTRS)
Ruddy, Frank H.; Patel, Jagdish U.; Williams, John G.
2005-01-01
Space reactor power monitors based on silicon carbide (SiC) semiconductor neutron detectors are proposed. Detection of fast leakage neutrons using SiC detectors in ex-core locations could be used to determine reactor power: Neutron fluxes, gamma-ray dose rates and ambient temperatures have been calculated as a function of distance from the reactor core, and the feasibility of power monitoring with SiC detectors has been evaluated at several ex-core locations. Arrays of SiC diodes can be configured to provide the required count rates to monitor reactor power from startup to full power Due to their resistance to temperature and the effects of neutron and gamma-ray exposure, SiC detectors can be expected to provide power monitoring information for the fill mission of a space reactor.
USDA-ARS?s Scientific Manuscript database
Prediction equations of energy expenditure (EE) using accelerometers and miniaturized heart rate (HR) monitors have been developed in older children and adults but not in preschool-aged children. Because the relationships between accelerometer counts (ACs), HR, and EE are confounded by growth and ma...
A habitat-based point-count protocol for terrestrial birds, emphasizing Washington and Oregon.
Mark H. Huff; Kelly A. Bettinger; Howard L. Ferguson; Martin J. Brown; Bob. Altman
2000-01-01
We describe a protocol and provide a summary for point-count monitoring of landbirds that is designed for habitat-based objectives. Presentation is in four steps: preparation and planning, selecting monitoring sites, establishing monitoring stations, and conducting point counts. We describe the basis for doing habitat-based point counts, how they are organized, and how...
Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas
NASA Technical Reports Server (NTRS)
Smith, Alan R.; Hurley, Donna L.
1991-01-01
Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low background Ge semiconductor detector gamma ray spectrometry. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit and radionuclides present initially as contaminants in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment related monitor foils and tomato seeds, and such spacecraft materials as Al, stainless steel, and Ti. In the second category are Al, Be, Ti, Va, and some special glasses. Consider that measured peak-area count rates from both categories range from a high value of about 1 count per minute down to less than 0.001 count per minute. Successful measurement of count rates toward the low end of this range can be achieved only through low background techniques, such as used to obtain the results presented here.
Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas
NASA Astrophysics Data System (ADS)
Smith, Alan R.; Hurley, Donna L.
1991-06-01
Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low background Ge semiconductor detector gamma ray spectrometry. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit and radionuclides present initially as contaminants in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment related monitor foils and tomato seeds, and such spacecraft materials as Al, stainless steel, and Ti. In the second category are Al, Be, Ti, Va, and some special glasses. Consider that measured peak-area count rates from both categories range from a high value of about 1 count per minute down to less than 0.001 count per minute. Successful measurement of count rates toward the low end of this range can be achieved only through low background techniques, such as used to obtain the results presented here.
Fermi GBM: Results from the First Year +
NASA Technical Reports Server (NTRS)
Wilson-Hodge, Colleen A.
2009-01-01
Gamma-ray Burst Monitor (GBM) has performed well in the first year+. GBM triggers 353 Gamma-ray Bursts (GRBs), 168 SGR events, 18 TGFs, and 1 solar flare to date. Short GRBs appear contracted in time and shifted to higher energy than long GRBs. Pulsed persistent emission from SGR 1550-5418 detected. TGFs are shorter, have higher average photon energies, and much higher count rates than GRBs. GBM monitoring of accreting pulsars provides long-term spin-histories. GBM Earth occultation monitoring complements Swift.
NASA Astrophysics Data System (ADS)
Soukup, B.; Johnson, W.; Repasky, K. S.; Carlsten, J. L.
2013-12-01
A scanning differential absorption lidar (DIAL) instrument for carbon sequestration site monitoring is under development and testing at Montana State University. The laser transmitter uses two tunable discrete mode laser diodes (DMLD) operating in the continuous wave (cw) mode with one locked to the on-line absorption wavelength at 1571.4067 nm and the second operating at the off-line wavelength at 1571.2585 nm. Two in-line fiber optic switches are used to switch between on-line and off-line operation. After the fiber optic switches, an acousto-optic modulator (AOM) is used to generate a pulse train used to injection seed an erbium doped fiber amplifier (EDFA) to produce eye-safe laser pulses with maximum pulse energies of 66 J and a pulse repetition frequency of 15 kHz. The DIAL receiver uses a 28 cm diameter Schmidt-Cassegrain telescope to collect that backscattered light, which is then monitored using a fiber coupled photo-multiplier tube (PMT) module operating in the photon counting mode. The PMT has a 3% quantum efficiency, a dark count rate of 90 kHz, and a maximum count rate of 1 MHz. Recently, a fiber coupled avalanche photodiode (APD) operating in the geiger mode has been incorporated into the DIAL receiver. The APD has a quantum efficiency of 10%, a dark count rate of 10 kHz, and a maximum count rate of 1 MHz and provides a much larger dynamic range than the PMT. Both the PMT and APD provide TTL logic pulses that are monitored using a multichannel scaler card used to count the return photons as a function of time of flight and are thus interchangeable. The DIAL instrument was developed at the 1.571 m wavelength to take advantage of commercial-off-the-shelf components. The instrument is operated using a custom Labview program that switches to the DMLD operating at the on-line wavelength, locks this laser to a user defined wavelength setting, and collects return signals for a user defined time. The control program switches to the DMLD operating at the off-line wavelength where data is again collected for a user defined time. The control program repeats this process until stopped by the operator. The DIAL instrument has been operated at the Zero Emission Research Technology (ZERT) field site located on the Montana State University campus and at the Big Sky Carbon Sequestration Partnership site located in north-central Montana. Data collected by the DIAL instrument at both field sites demonstrate that the DIAL is capable of retrieving night time CO2 number density profiles out to a range of 2.5 km with a 150 m range resolution. The DIAL retrievals are validated using a co-located Li-COR 820 gas analyzer placed along the DIAL optical path allowing comparison at a single range as a function of time.
Bütikofer, R; Flückiger, E O; Desorgher, L; Moser, M R
2008-03-01
In January 2005 toward the end of solar activity cycle 23 the Sun was very active. Between 15 and 20 January 2005, the solar active region NOAA AR 10720 produced five powerful solar flares. In association with this major solar activity several pronounced variations in the ground-level cosmic ray intensity were observed. The fifth of these flares (X7.1) produced energetic solar cosmic rays that caused a giant increase in the count rates of the ground-based cosmic ray detectors (neutron monitors). At southern polar neutron monitor stations the increase of the count rate reached several thousand percent. From the recordings of the worldwide network of neutron monitors, we determined the characteristics of the solar particle flux near Earth. In the initial phase of the event, the solar cosmic ray flux near Earth was extremely anisotropic. The energy spectrum of the solar cosmic rays was fairly soft during the main and the decay phase. We investigated also the flux of different secondary particle species in the atmosphere and the radiation dosage at flight altitude. Our analysis shows a maximum increment of the effective dose rate due to solar cosmic rays in the south polar region around 70 degrees S and 130 degrees E at flight altitude of almost three orders of magnitude.
NASA Astrophysics Data System (ADS)
Kassim, Muhammad Fuad bin; Norzali Haji Mohd, Mohd
2017-08-01
Technology is all about helping people, which created a new opportunity to take serious action in managing their health care. Moreover, Obesity continues to be a serious public health concern in the Malaysia and continuing to rise. Obesity has been a serious health concern among people. Nearly half of Malaysian people overweight. Most of dietary approach is not tracking and detecting the right calorie intake for weight loss, but currently used tools such as food diaries require users to manually record and track the food calories, making them difficult for daily use. We will be developing a new tool that counts the food intake bite by monitoring hand gesture and face jaw motion movement of caloric intake. The Bite count method showed a good significant that can lead to a successful weight loss by simply monitoring the bite taken during eating. The device used was Kinect Xbox One which used a depth camera to detect the motion on person hand and face during food intake. Previous studies showed that most of the method used to count bite device is worn type. The recent trend is now going towards non-wearable devices due to the difficulty when wearing devices and it has high false alarm ratio. The proposed system gets data from the Kinect that will be monitoring the hand and face gesture of the user while eating. Then, the gesture of hand and face data is sent to the microcontroller board to recognize and start counting bite taken by the user. The system recognizes the patterns of bite taken from user by following the algorithm of basic eating type either using hand or chopstick. This system can help people who are trying to follow a proper way to reduce overweight or eating disorders by monitoring their meal intake and controlling eating rate.
Effects of SMEAT on the oral health of crewmen (DTO 71-2). [dental hygiene
NASA Technical Reports Server (NTRS)
Brown, L. R.; Wheatcroft, M. G.
1973-01-01
The oral health status of three astronauts was monitored before, during and after a 56-day simulation of the Skylab mission. Laboratory and clinical parameters which are considered to be ultimately related to dental impairments were evaluated. The most notable changes were observed in increased counts of mycoplasma and S. mutans, decreased counts of enteric bacilli, decreased saliva flow rates, increased secretory IgA and salivary lysozyme levels, and increased clinical scores of dental plaque, calculus and inflammation.
Measuring and Modeling Cosmic Ray Showers with an MBL System: An Undergraduate Project.
ERIC Educational Resources Information Center
Jackson, David P.; Welker, Matthew T.
2001-01-01
Describes a novel method for inducing and measuring cosmic ray showers using a low-cost, microcomputer-based laboratory system. Uses low counting-rate radiation monitors in the reproduction of Bruno Rossi's classic experiment. (Contains 16 references.) (Author/YDS)
Tripathi, R M; Sumesh, C G; Vinod Kumar, A; Puranik, V D
2013-07-01
Pulse ionisation chamber (PIC)-based monitors measuring radioactive gas radon ((222)Rn) without energy discrimination will have interference due to thoron ((220)Rn) present in the atmosphere. A technique has been developed to use this property of interference for simultaneous measurement of radon and thoron gas. These monitors work on the principle of counting of gross alphas emitted from radon and its progeny. A theoretical model has been developed for the variation of thoron sensitivity with respect to the flow rate of gas through the monitor. The thoron sensitivity of the monitor is found to vary with the flow rate of gas through the monitor. Using this sensitivity, the sampling procedure has been developed and verified for simultaneous measurement of radon and thoron. The PIC-measured radon and thoron concentration using this procedure agrees well with those measured by using standard radon and thoron discriminating monitor.
Influence of Point Count Length and Repeated Visits on Habitat Model Performance
Randy Dettmers; David A. Buehler; John G. Bartlett; Nathan A. Klaus
1999-01-01
Point counts are commonly used to monitor bird populations, and a substantial amount of research has investigated how conducting counts for different lengths of time affects the accuracy of these counts and the subsequent ability to monitor changes in population trends. However, little work has been done io assess how changes in count duration affect bird-habitat...
NASA Astrophysics Data System (ADS)
Pierre Auger Collaboration; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Ambrosio, M.; Aminaei, A.; Anchordoqui, L.; Andringa, S.; Antičić, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avenier, M.; Avila, G.; Bäcker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Bardenet, R.; Barroso, S. L. C.; Baughman, B.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Bellétoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Dembinski, H.; Denkiewicz, A.; Di Giulio, C.; Diaz, J. C.; Díaz Castro, M. L.; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferguson, A. P.; Ferrero, A.; Fick, B.; Filevich, A.; Filipčič, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Fröhlich, U.; Fuchs, B.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; García, B.; García Gámez, D.; Garcia-Pinto, D.; Garrido, X.; Gascon, A.; Gelmini, G.; Gemmeke, H.; Gesterling, K.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gómez Berisso, M.; Gonçalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gookin, B.; Góra, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hórandel, J. R.; Horneffer, A.; Hrabovský, M.; Huege, T.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karhan, P.; Karova, T.; Kasper, P.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kelley, J. L.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapp, J.; Koang, D.-H.; Kotera, K.; Krohm, N.; Krömer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, J. K.; Kunka, N.; La Rosa, G.; Lachaud, C.; Lautridou, P.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martin, L.; Martínez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Mičanović, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafá, M.; Mueller, S.; Muller, M. A.; Müller, G.; Münchmeyer, M.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nožka, L.; Nyklicek, M.; Oehlschläger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou c, V.; Payet, K.; Pech, M.; Pękala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Phan, N.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Revenu, B.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rivera, H.; Rivière, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouillé-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sánchez, F.; Santander, M.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovánek, P.; Schroeder, F.; Schulte, S.; Schüssler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Sigl, G.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stapleton, J.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Šuša, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tapia, A.; Tarutina, T.; Taşcǎu, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tiwari, D. K.; Tkaczyk, W.; Todero Peixoto, C. J.; Tomé, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van den Berg, A. M.; Vargas Cárdenas, B.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Venters, T.; Verzi, V.; Videla, M.; Villaseñor, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Weber, M.; Weidenhaupt, K.; Weindl, A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Will, M.; Williams, C.; Winchen, T.; Winders, L.; Winnick, M. G.; Wommer, M.; Wundheiler, B.; Yamamoto a, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zamorano, B.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.
2011-01-01
Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation with neutron monitor data is found.
Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting.
Treacy, Daniel; Hassett, Leanne; Schurr, Karl; Chagpar, Sakina; Paul, Serene S; Sherrington, Catherine
2017-05-01
Commonly used activity monitors have been shown to be accurate in counting steps in active people; however, further validation is needed in slower walking populations. To determine the validity of activity monitors for measuring step counts in rehabilitation inpatients compared with visually observed step counts. To explore the influence of gait parameters, activity monitor position, and use of walkers on activity monitor accuracy. One hundred and sixty-six inpatients admitted to a rehabilitation unit with an average walking speed of 0.4 m/s (SD 0.2) wore 16 activity monitors (7 different devices in different positions) simultaneously during 6-minute and 6-m walks. The number of steps taken during the tests was also counted by a physical therapist. Gait parameters were assessed using the GAITRite system. To analyze the influence of different gait parameters, the percentage accuracy for each monitor was graphed against various gait parameters for each activity monitor. The StepWatch, Fitbit One worn on the ankle and the ActivPAL showed excellent agreement with observed step count (ICC 2,1 0.98; 0.92; 0.78 respectively). Other devices (Fitbit Charge, Fitbit One worn on hip, G-Sensor, Garmin Vivofit, Actigraph) showed poor agreement with the observed step count (ICC 2,1 0.12-0.40). Percentage agreement with observed step count was highest for the StepWatch (mean 98%). The StepWatch and the Fitbit One worn on the ankle maintained accuracy in individuals who walked more slowly and with shorter strides but other devices were less accurate in these individuals. There were small numbers of participants for some gait parameters. The StepWatch showed the highest accuracy and closest agreement with observed step count. This device can be confidently used by researchers for accurate measurement of step counts in inpatient rehabilitation in individuals who walk slowly. If immediate feedback is desired, the Fitbit One when worn on the ankle would be the best choice for this population. © 2017 American Physical Therapy Association
Activity Monitors Step Count Accuracy in Community-Dwelling Older Adults.
Johnson, Marquell
2015-01-01
Objective: To examine the step count accuracy of activity monitors in community-dwelling older adults. Method : Twenty-nine participants aged 67.70 ± 6.07 participated. Three pedometers and the Actical accelerometer step count functions were compared with actual steps taken during a 200-m walk around an indoor track and during treadmill walking at three different speeds. Results : There was no statistical difference between activity monitors step counts and actual steps during self-selected pace walking. During treadmill walking at 0.67 m∙s -1 , all activity monitors step counts were significantly different from actual steps. During treadmill walking at 0.894m∙s -1 , the Omron HJ-112 pedometer step counts were not significantly different from actual steps. During treadmill walking at 1.12 m∙s -1 , the Yamax SW-200 pedometer steps were significantly different from actual steps. Discussion : Activity monitor selection should be deliberate when examining the walking behaviors of community-dwelling older adults, especially for those who walk at a slower pace.
Activity Monitors Step Count Accuracy in Community-Dwelling Older Adults
2015-01-01
Objective: To examine the step count accuracy of activity monitors in community-dwelling older adults. Method: Twenty-nine participants aged 67.70 ± 6.07 participated. Three pedometers and the Actical accelerometer step count functions were compared with actual steps taken during a 200-m walk around an indoor track and during treadmill walking at three different speeds. Results: There was no statistical difference between activity monitors step counts and actual steps during self-selected pace walking. During treadmill walking at 0.67 m∙s−1, all activity monitors step counts were significantly different from actual steps. During treadmill walking at 0.894m∙s−1, the Omron HJ-112 pedometer step counts were not significantly different from actual steps. During treadmill walking at 1.12 m∙s−1, the Yamax SW-200 pedometer steps were significantly different from actual steps. Discussion: Activity monitor selection should be deliberate when examining the walking behaviors of community-dwelling older adults, especially for those who walk at a slower pace. PMID:28138464
Monitoring bird populations by point counts
C. John Ralph; John R. Sauer; Sam Droege
1995-01-01
This volume contains in part papers presented at the Symposium on Monitoring Bird Population Trends by Point Counts, which was held November 6-7, 1991, in Beltsville, Md., in response to the need for standardization of methods to monitor bird populations by point counts. Data from various investigators working under a wide variety of conditions are presented, and...
Tornheim, Jeffrey A.; Lozano Beltran, Daniel F.; Gilman, Robert H.; Castellon, Mario; Solano Mercado, Marco A.; Sullca, Walter; Torrico, Faustino; Bern, Caryn
2013-01-01
Background Chagas disease treatment is limited by drug availability, adverse side effect profiles of available medications, and poor adherence. Methods Adult Chagas disease patients initiating 60-days of benznidazole were randomized to weekly or twice-weekly evaluations of medication adherence and screening for adverse drug events (ADEs). Mid-week evaluations employed phone-based evaluations. Adherence was measured by self-report, pill counts with intentional over-distribution, and Medication Event Monitoring Systems (MEMS). Prospective data were compared to historical controls treated with benznidazole at the same hospital. Results 162 prospective patients were compared to 172 historical patients. Pill counts correlated well with MEMS data (R = 0.498 for 7-day intervals, R = 0.872 for intervals >7 days). Treatment completion rates were higher among prospective than historical patients (82.1% vs. 65.1%), primarily due to lower abandonment rates. Rates of ADEs were lower among prospective than historical patients (56.8% vs. 66.9%). Twice-weekly evaluations increased identification of mild ADEs, prompting higher suspension rates than weekly evaluations. While twice-weekly evaluations identified ADEs earlier, they did not reduce incidence of moderate or severe ADEs. Many dermatologic ADEs were moderately severe upon presentation (35.6%), were not reduced by use of antihistamines, occurred among adult patients of all ages, and occurred throughout treatment, rather than the first few weeks alone. Conclusions Intensive management improved completion and identified more ADEs, but did not reduce moderate or severe ADEs. Risk of dermatologic ADEs cannot be reduced by selecting younger adults or monitoring only during the first few weeks of treatment. Pill counts and phone-based encounters are reliable tools for treatment programming in rural Bolivia. PMID:24069472
The automated counting of beating rates in individual cultured heart cells.
Collins, G A; Dower, R; Walker, M J
1981-12-01
The effect of drugs on the beating rate of cultured heart cells can be monitored in a number of ways. The simultaneous automated measurement of beating rates of a number of cells allows drug effects to be rapidly quantified. A photoresistive detector placed on a television image of a cell, when coupled to operational amplifiers, gives binary signals that can be processed by a microprocessor. On this basis, we have devised a system that is capable of simultaneously monitoring the individual beating of six single cultured heart cells. A microprocessor automatically processes data obtained under different experimental conditions and records it in suitable descriptive formats such as dose-response curves and double reciprocal plots.
Background compensation for a radiation level monitor
Keefe, D.J.
1975-12-01
Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.
Single photon detection using Geiger mode CMOS avalanche photodiodes
NASA Astrophysics Data System (ADS)
Lawrence, William G.; Stapels, Christopher; Augustine, Frank L.; Christian, James F.
2005-10-01
Geiger mode Avalanche Photodiodes fabricated using complementary metal-oxide-semiconductor (CMOS) fabrication technology combine high sensitivity detectors with pixel-level auxiliary circuitry. Radiation Monitoring Devices has successfully implemented CMOS manufacturing techniques to develop prototype detectors with active diameters ranging from 5 to 60 microns and measured detection efficiencies of up to 60%. CMOS active quenching circuits are included in the pixel layout. The actively quenched pixels have a quenching time less than 30 ns and a maximum count rate greater than 10 MHz. The actively quenched Geiger mode avalanche photodiode (GPD) has linear response at room temperature over six orders of magnitude. When operating in Geiger mode, these GPDs act as single photon-counting detectors that produce a digital output pulse for each photon with no associated read noise. Thermoelectrically cooled detectors have less than 1 Hz dark counts. The detection efficiency, dark count rate, and after-pulsing of two different pixel designs are measured and demonstrate the differences in the device operation. Additional applications for these devices include nuclear imaging and replacement of photomultiplier tubes in dosimeters.
Xing, Jian; Burkom, Howard; Moniz, Linda; Edgerton, James; Leuze, Michael; Tokars, Jerome
2009-01-01
Background The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement. PMID:19615075
NASA Astrophysics Data System (ADS)
Degenaar, N.; Wijnands, R.; Reynolds, M. T.; Miller, J. M.; Kennea, J. A.
2017-10-01
Daily Swift/XRT monitoring observations of the Galactic center (Degenaar et al. 2015) have picked up renewed activity of the transient neutron star low-mass X-ray binary and thermonuclear X-ray burster GRS 1741-2853, which is located 10 arcmin NW of Sgr A*. During a 1 ks PC-mode observation performed on 2017 October 11 the source is detected at a net count rate of 0.015 counts/s and it has been steadily brightening since, indicating the onset of a new accretion outburst.
Sperm count as a surrogate endpoint for male fertility control.
Benda, Norbert; Gerlinger, Christoph
2007-11-30
When assessing the effectiveness of a hormonal method of fertility control in men, the classical approach used for the assessment of hormonal contraceptives in women, by estimating the pregnancy rate or using a life-table analysis for the time to pregnancy, is difficult to apply in a clinical development program. The main reasons are the dissociation of the treated unit, i.e. the man, and the observed unit, i.e. his female partner, the high variability in the frequency of male intercourse, the logistical cost and ethical concerns related to the monitoring of the trial. A reasonable surrogate endpoint of the definite endpoint time to pregnancy is sperm count. In addition to the avoidance of the mentioned problems, trials that compare different treatments are possible with reasonable sample sizes, and study duration can be shorter. However, current products do not suppress sperm production to 100 per cent in all men and the sperm count is only observed with measurement error. Complete azoospermia might not be necessary in order to achieve an acceptable failure rate compared with other forms of male fertility control. Therefore, the use of sperm count as a surrogate endpoint must rely on the results of a previous trial in which both the definitive- and surrogate-endpoint results were assessed. The paper discusses different estimation functions of the mean pregnancy rate (corresponding to the cumulative hazard) that are based on the results of sperm count trial and a previous trial in which both sperm count and time to pregnancy were assessed, as well as the underlying assumptions. Sample size estimations are given for pregnancy rate estimation with a given precision.
Souto, Luís I M; Minagawa, Clarice Y; Telles, Evelise O; Garbuglio, Márcio A; Amaku, Marcos; Melville, Priscilla A; Dias, Ricardo A; Sakata, Sonia T; Benites, Nilson R
2010-02-01
Milk is the normal secretion of the mammary gland, practically free of colostrum and obtained by the complete milking of one or more healthy animals. Mastitis is an inflammatory process of the mammary gland and it may cause alterations in the milk. The present work aimed to verify whether it is possible, by means of the counts of microorganism in the bulk raw milk in four selective culture media, to establish a correlation with the occurrence of mastitis and therefore, to monitor this disease in bovine dairy herds. The following selective culture media were used: KF Streptococcus Agar, Edwards Agar, Baird-Parker Agar, Blood Agar plus potassium tellurite. Spearman's correlation coefficient was calculated in order to compare the occurrence of mastitis (percentage) in each herd with respective selective culture media counts of microorganisms in bulk raw milk. Thirty-six possibilities were analysed (Tamis and CMT-positive rates were compared with the log-transformed count in four selective culture media) and there was a negative correlation between Tamis 3 and the Baird-Parker Agar plate count. The total results of microbiological tests showed that there were three correlations of the counts in selective culture media. Fifty-two possibilities were analysed and there was a negative correlation between no-bacterial-growth mastitis rates and log10 of KF Streptoccocus Agar plate count and there were two positive correlations between coagulase-positive staphylococci and log10 of Baird-Parker Agar plate count and Blood Agar plus potassium tellurite plate count.
Health Monitor for Multitasking, Safety-Critical, Real-Time Software
NASA Technical Reports Server (NTRS)
Zoerner, Roger
2011-01-01
Health Manager can detect Bad Health prior to a failure occurring by periodically monitoring the application software by looking for code corruption errors, and sanity-checking each critical data value prior to use. A processor s memory can fail and corrupt the software, or the software can accidentally write to the wrong address and overwrite the executing software. This innovation will continuously calculate a checksum of the software load to detect corrupted code. This will allow a system to detect a failure before it happens. This innovation monitors each software task (thread) so that if any task reports "bad health," or does not report to the Health Manager, the system is declared bad. The Health Manager reports overall system health to the outside world by outputting a square wave signal. If the square wave stops, this indicates that system health is bad or hung and cannot report. Either way, "bad health" can be detected, whether caused by an error, corrupted data, or a hung processor. A separate Health Monitor Task is started and run periodically in a loop that starts and stops pending on a semaphore. Each monitored task registers with the Health Manager, which maintains a count for the task. The registering task must indicate if it will run more or less often than the Health Manager. If the task runs more often than the Health Manager, the monitored task calls a health function that increments the count and verifies it did not go over max-count. When the periodic Health Manager runs, it verifies that the count did not go over the max-count and zeroes it. If the task runs less often than the Health Manager, the periodic Health Manager will increment the count. The monitored task zeroes the count, and both the Health Manager and monitored task verify that the count did not go over the max-count.
Reliability of Multi-Category Rating Scales
ERIC Educational Resources Information Center
Parker, Richard I.; Vannest, Kimberly J.; Davis, John L.
2013-01-01
The use of multi-category scales is increasing for the monitoring of IEP goals, classroom and school rules, and Behavior Improvement Plans (BIPs). Although they require greater inference than traditional data counting, little is known about the inter-rater reliability of these scales. This simulation study examined the performance of nine…
Kirton, Laurence G.; Yusoff, Norma-Rashid
2017-01-01
The Rajah Brooke's Birdwing, Trogonoptera brookiana, is a large, iconic butterfly that is facing heavy commercial exploitation and habitat loss. Males of some subspecies exhibit puddling behavior. A method of conservation monitoring was developed for subspecies albescens in Ulu Geroh, Peninsular Malaysia, where the males consistently puddle in single-species aggregations at stable geothermal springs, reaching well over 300 individuals when the population is at its highest. Digital photography was used to conduct counts of numbers of males puddling. The numbers of birdwings puddling were significantly correlated with counts of birdwings in flight, but were much higher. The numbers puddling during the peak hour were correlated with numbers puddling throughout the day and could be predicted using the numbers puddling at an alternative hour, enabling flexibility in the time of counts. Average counts for three images taken at each puddle at three peak hours between 1400–1600 hours over 2–3 days were used as a monthly population index. The numbers puddling were positively associated with higher relative humidity and brightness during monitoring hours. Monthly counts of birdwings from monitoring of puddles over a period of two years are presented. The minimum effort required for a monitoring program using counts of puddling males is discussed, as well as the potential of using the method to monitor other species of puddling butterflies. PMID:29232405
Phon, Chooi-Khim; Kirton, Laurence G; Norma-Rashid, Yusoff
2017-01-01
The Rajah Brooke's Birdwing, Trogonoptera brookiana, is a large, iconic butterfly that is facing heavy commercial exploitation and habitat loss. Males of some subspecies exhibit puddling behavior. A method of conservation monitoring was developed for subspecies albescens in Ulu Geroh, Peninsular Malaysia, where the males consistently puddle in single-species aggregations at stable geothermal springs, reaching well over 300 individuals when the population is at its highest. Digital photography was used to conduct counts of numbers of males puddling. The numbers of birdwings puddling were significantly correlated with counts of birdwings in flight, but were much higher. The numbers puddling during the peak hour were correlated with numbers puddling throughout the day and could be predicted using the numbers puddling at an alternative hour, enabling flexibility in the time of counts. Average counts for three images taken at each puddle at three peak hours between 1400-1600 hours over 2-3 days were used as a monthly population index. The numbers puddling were positively associated with higher relative humidity and brightness during monitoring hours. Monthly counts of birdwings from monitoring of puddles over a period of two years are presented. The minimum effort required for a monitoring program using counts of puddling males is discussed, as well as the potential of using the method to monitor other species of puddling butterflies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abreu, P.; /Lisbon, LIFEP /Lisbon, IST; Aglietta, M.
2011-01-01
Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation withmore » neutron monitor data is found.« less
The ONR-602 experiment and investigation of particle precipitation near the equator
NASA Technical Reports Server (NTRS)
Miah, M. A.
1991-01-01
The global precipitation of radiation belt particles at low altitude was investigated, using the ONR-602 experiment on board U.S. Air Force mission S81-1. A combination of a main telescope, beginning analysis at a few MeV/nucleon, and a monitor system, giving results below 1 MeV/nucleon, was designed for measuring particle phenomena characterized by almost any energy spectrum. The monitor provides an indication of the presence of the particles at low energy, while the main telescope gives detailed flux and composition data for the higher energy events. Results of the instrument performance analysis indicate that, at the equator, the monitor telescope has the peak efficiency for particles of about 90 deg pitch angles. The large opening angle of 75 deg makes it possible to detect omnidirectional flux of quasi-trapped particles. The high-energy cosmic-ray background count is found to be very insignificant. It is demonstrated that the particle counting rates for the low-energy threshold have been almost entirely due to protons.
An Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations.
Beevi, Femina H A; Miranda, Jorge; Pedersen, Christian F; Wagner, Stefan
2016-05-01
Pedometers are considered desirable devices for monitoring physical activity. Two population groups of interest include patients having undergone surgery in the lower extremities or who are otherwise weakened through disease, medical treatment, or surgery procedures, as well as the slow walking senior population. For these population groups, pedometers must be able to perform reliably and accurately at slow walking speeds. The objectives of this study were to evaluate the step count accuracy of three commercially available pedometers, the Yamax (Tokyo, Japan) Digi-Walker(®) SW-200 (YM), the Omron (Kyoto, Japan) HJ-720 (OM), and the Fitbit (San Francisco, CA) Zip (FB), at slow walking speeds, specifically at 1, 2, and 3 km/h, and to raise awareness of the necessity of focusing research on step-counting devices and algorithms for slow walking populations. Fourteen participants 29.93 ±4.93 years of age were requested to walk on a treadmill at the three specified speeds, in four trials of 100 steps each. The devices were worn by the participants on the waist belt. The pedometer counts were recorded, and the error percentage was calculated. The error rate of all three evaluated pedometers decreased with the increase of speed: at 1 km/h the error rates varied from 87.11% (YM) to 95.98% (FB), at 2 km/h the error rates varied from 17.27% (FB) to 46.46% (YM), and at 3 km/h the error rates varied from 22.46% (YM) to a slight overcount of 0.70% (FB). It was observed that all the evaluated devices have high error rates at 1 km/h and mixed error rates at 2 km/h, and at 3 km/h the error rates are the smallest of the three assessed speeds, with the OM and the FB having a slight overcount. These results show that research on pedometers' software and hardware should focus more on accurate step detection at slow walking speeds.
Fedy, B.C.; Aldridge, Cameron L.
2011-01-01
Long-term population monitoring is the cornerstone of animal conservation and management. The accuracy and precision of models developed using monitoring data can be influenced by the protocols guiding data collection. The greater sage-grouse (Centrocercus urophasianus) is a species of concern that has been monitored over decades, primarily, by counting the number of males that attend lek (breeding) sites. These lek count data have been used to assess long-term population trends and for multiple mechanistic studies. However, some studies have questioned the efficacy of lek counts to accurately identify population trends. In response, monitoring protocols were changed to have a goal of counting lek sites multiple times within a season. We assessed the influence of this change in monitoring protocols on model accuracy and precision applying generalized additive models to describe trends over time. We found that at large spatial scales including >50 leks, the absence of repeated counts within a year did not significantly alter population trend estimates or interpretation. Increasing sample size decreased the model confidence intervals. We developed a population trend model for Wyoming greater sage-grouse from 1965 to 2008, identifying significant changes in the population indices and capturing the cyclic nature of this species. Most sage-grouse declines in Wyoming occurred between 1965 and the 1990s and lek count numbers generally increased from the mid-1990s to 2008. Our results validate the combination of monitoring data collected under different protocols in past and future studies-provided those studies are addressing large-scale questions. We suggest that a larger sample of individual leks is preferable to multiple counts of a smaller sample of leks. ?? 2011 The Wildlife Society.
NASA Astrophysics Data System (ADS)
Yanbe, Yutaka; Sato, Eiichi; Chiba, Hiraku; Maeda, Tomoko; Matsushita, Ryo; Oda, Yasuyuki; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira
2013-09-01
X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects. Bremsstrahlung X-rays with energies beyond tantalum (Ta) K-edge energy 67.4 keV are absorbed effectively using a 100-µm-thick Ta filter, and the filtered X-rays including tungsten (W) Kα rays are absorbed by gadolinium (Gd) atoms in objects. The Gd XRF is then produced from Gd atoms in the objects and is counted by a cadmium telluride (CdTe) detector. Gd Kα photons with a maximum count rate of 1 kilo counts per second are dispersed using a multichannel analyzer, and the number of photons is counted by a counter card. The distance between the CdTe detector and the object is minimized to 40 mm to increase the count rate. The object is scanned using an x-y stage with a velocity of 5.0 mm/s, and Gd mapping are shown on a computer monitor. The scan steps of the x- and y-axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We obtained Gd XRF images at high contrast, and Gd Kα photons were easily detected from cancerous regions in a nude mouse placed behind a 20-mm-thick poly(methyl methacrylate) plate.
Pomeroy, Jeremy; Brage, Søren; Curtis, Jeffrey M; Swan, Pamela D; Knowler, William C; Franks, Paul W
2011-04-27
The quantification of the relationships between walking and health requires that walking is measured accurately. We correlated different measures of step accumulation to body size, overall physical activity level, and glucose regulation. Participants were 25 men and 25 women American Indians without diabetes (Age: 20-34 years) in Phoenix, Arizona, USA. We assessed steps/day during 7 days of free living, simultaneously with three different monitors (Accusplit-AX120, MTI-ActiGraph, and Dynastream-AMP). We assessed total physical activity during free-living with doubly labeled water combined with resting metabolic rate measured by expired gas indirect calorimetry. Glucose tolerance was determined during an oral glucose tolerance test. Based on observed counts in the laboratory, the AMP was the most accurate device, followed by the MTI and the AX120, respectively. The estimated energy cost of 1000 steps per day was lower in the AX120 than the MTI or AMP. The correlation between AX120-assessed steps/day and waist circumference was significantly higher than the correlation between AMP steps and waist circumference. The difference in steps per day between the AX120 and both the AMP and the MTI were significantly related to waist circumference. Between-monitor differences in step counts influence the observed relationship between walking and obesity-related traits.
Klingbeil, Brian T; Willig, Michael R
2015-01-01
Effective monitoring programs for biodiversity are needed to assess trends in biodiversity and evaluate the consequences of management. This is particularly true for birds and faunas that occupy interior forest and other areas of low human population density, as these are frequently under-sampled compared to other habitats. For birds, Autonomous Recording Units (ARUs) have been proposed as a supplement or alternative to point counts made by human observers to enhance monitoring efforts. We employed two strategies (i.e., simultaneous-collection and same-season) to compare point count and ARU methods for quantifying species richness and composition of birds in temperate interior forests. The simultaneous-collection strategy compares surveys by ARUs and point counts, with methods matched in time, location, and survey duration such that the person and machine simultaneously collect data. The same-season strategy compares surveys from ARUs and point counts conducted at the same locations throughout the breeding season, but methods differ in the number, duration, and frequency of surveys. This second strategy more closely follows the ways in which monitoring programs are likely to be implemented. Site-specific estimates of richness (but not species composition) differed between methods; however, the nature of the relationship was dependent on the assessment strategy. Estimates of richness from point counts were greater than estimates from ARUs in the simultaneous-collection strategy. Woodpeckers in particular, were less frequently identified from ARUs than point counts with this strategy. Conversely, estimates of richness were lower from point counts than ARUs in the same-season strategy. Moreover, in the same-season strategy, ARUs detected the occurrence of passerines at a higher frequency than did point counts. Differences between ARU and point count methods were only detected in site-level comparisons. Importantly, both methods provide similar estimates of species richness and composition for the region. Consequently, if single visits to sites or short-term monitoring are the goal, point counts will likely perform better than ARUs, especially if species are rare or vocalize infrequently. However, if seasonal or annual monitoring of sites is the goal, ARUs offer a viable alternative to standard point-count methods, especially in the context of large-scale or long-term monitoring of temperate forest birds.
Low-background gamma-ray spectrometry for the international monitoring system
Greenwood, L. R.; Cantaloub, M. G.; Burnett, J. L.; ...
2016-12-28
PNNL has developed two low-background gamma-ray spectrometers in a new shallow underground laboratory, thereby significantly improving its ability to detect low levels of gamma-ray emitting fission or activation products in airborne particulate in samples from the IMS (International Monitoring System). Furthermore, the combination of cosmic veto panels, dry nitrogen gas to reduce radon and low background shielding results in a reduction of the background count rate by about a factor of 100 compared to detectors operating above ground at our laboratory.
CONTROL CONSOLE FOR MTR FISSION PRODUCT MONITOR, USED TO DETECT ...
CONTROL CONSOLE FOR MTR FISSION PRODUCT MONITOR, USED TO DETECT BREAKS IN CLADDING OF FUEL ELEMENTS. COUNT-RATE METER IN TOP PANEL INDICATES AMOUNT OF RADIOACTIVITY. LOWER PANELS SUPPLY POWER AND AMPLIFICATION OF SIGNALS GENERATED BY SCINTILLATION COUNTER/PHOTOMULTIPLIER TUBE COMBINATION IN RESPONSE TO RADIOACTIVITY IN A SAMPLE OF THE COOLING WATER. INL NEGATIVE NO. 56-771. Jack L. Anderson, Photographer, 3/15/1956. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Monitoring trends in bird populations: addressing background levels of annual variability in counts
Jared Verner; Kathryn L. Purcell; Jennifer G. Turner
1996-01-01
Point counting has been widely accepted as a method for monitoring trends in bird populations. Using a rigorously standardized protocol at 210 counting stations at the San Joaquin Experimental Range, Madera Co., California, we have been studying sources of variability in point counts of birds. Vegetation types in the study area have not changed during the 11 years of...
Gross beta determination in drinking water using scintillating fiber array detector.
Lv, Wen-Hui; Yi, Hong-Chang; Liu, Tong-Qing; Zeng, Zhi; Li, Jun-Li; Zhang, Hui; Ma, Hao
2018-04-04
A scintillating fiber array detector for measuring gross beta counting is developed to monitor the real-time radioactivity in drinking water. The detector, placed in a stainless-steel tank, consists of 1096 scintillating fibers, both sides of which are connected to a photomultiplier tube. The detector parameters, including working voltage, background counting rate and stability, are tested, and the detection efficiency is calibrated using standard potassium chloride solution. Water samples are measured with the detector and the results are compared with those by evaporation method. The results show consistency with those by evaporation method. The background counting rate of the detector is 38.131 ± 0.005 cps, and the detection efficiency for β particles is 0.37 ± 0.01 cps/(Bq/l). The MDAC of this system can be less than 1.0 Bq/l for β particles in 120 min without pre-concentration. Copyright © 2018 Elsevier Ltd. All rights reserved.
Nova Lup 2016 during the X-ray decay phase
NASA Astrophysics Data System (ADS)
Orio, Marina; Beardmore, Andrew; Page, Kim; Osborne, Julian
2017-09-01
Nova Lup 2016 (ASASSN-16kt; see ATel #9538, #9539, #8550, #9554, #9587, #9594 and #9644) has been regularly monitored with Swift since the observations published in ATel #10632 that revealed a luminous supersoft X-ray source with a peak XRT count rate of 61.1(+-)0.1 cts/s on 2017/2/22.
El-Amrawy, Fatema
2015-01-01
Objectives The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Methods Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. Results The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. Conclusions The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure. PMID:26618039
El-Amrawy, Fatema; Nounou, Mohamed Ismail
2015-10-01
The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure.
NASA Astrophysics Data System (ADS)
Krantz, C.; Novotný, O.; Becker, A.; George, S.; Grieser, M.; Hahn, R. von; Meyer, C.; Schippers, S.; Spruck, K.; Vogel, S.; Wolf, A.
2017-04-01
We have used a single-particle detector system, based on secondary electron emission, for counting low-energetic (∼keV/u) massive products originating from atomic and molecular ion reactions in the electrostatic Cryogenic Storage Ring (CSR). The detector is movable within the cryogenic vacuum chamber of CSR, and was used to measure production rates of a variety of charged and neutral daughter particles. In operation at a temperature of ∼ 6 K , the detector is characterised by a high dynamic range, combining a low dark event rate with good high-rate particle counting capability. On-line measurement of the pulse height distributions proved to be an important monitor of the detector response at low temperature. Statistical pulse-height analysis allows to infer the particle detection efficiency of the detector, which has been found to be close to unity also in cryogenic operation at 6 K.
Development of an alpha/beta/gamma detector for radiation monitoring
NASA Astrophysics Data System (ADS)
Yamamoto, Seiichi; Hatazawa, Jun
2011-11-01
For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.
In-line wear monitor. Final report, July 1988-April 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pieper, K.A.; Taylor, I.J.
This report describes construction and test results of an in-line monitor for critical ferrous and nonferrous metal debris in turbine engine lubrication systems. The in-line wear monitor (ILWM) uses the X-ray fluorescence principle for detecting metal debris on a continuous basis while the engine is running. The sensor portion of the system is engine mounted and contains a radioactive X-ray source, a flow cell to direct the oil across an X-ray permeable window, a proportional counter X-ray detector and its associated preamplifier and amplifier electronics. The data acquisition electronics is mounted on the airframe and contains a microprocessor based systemmore » for inputting pulses from the sensor, classifying and counting them according to energy bands, and analyzing the data and outputting metal concentration values to the engine monitoring system. The sensor portion of the system is designed to fit on a TF41 turbine engine in place of a tube between the oil tank and the oil pump. A TF41 engine monitoring system has been modified to accept the new signals from the ILWM on spare inputs so that none of the existing functions were disturbed. The ILWM has been flow tested at various flow rates, concentration levels, oil temperatures, and aerations. The wear monitor detected iron, copper, and both iron and copper together with less than 2 ppm one sigma statistical uncertainty for 30 minute count times over the 0-50 ppm range. There was no significant effect of flow rate or aeration on accuracy. The system is developed to the point that it can be tested in an actual flight environment.« less
Development of an alpha/beta/gamma detector for radiation monitoring.
Yamamoto, Seiichi; Hatazawa, Jun
2011-11-01
For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd(2)SiO(5) (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required. © 2011 American Institute of Physics
Role of data aggregation in biosurveillance detection strategies with applications from ESSENCE.
Burkom, Howard S; Elbert, Y; Feldman, A; Lin, J
2004-09-24
Syndromic surveillance systems are used to monitor daily electronic data streams for anomalous counts of features of varying specificity. The monitored quantities might be counts of clinical diagnoses, sales of over-the-counter influenza remedies, school absenteeism among a given age group, and so forth. Basic data-aggregation decisions for these systems include determining which records to count and how to group them in space and time. This paper discusses the application of spatial and temporal data-aggregation strategies for multiple data streams to alerting algorithms appropriate to the surveillance region and public health threat of interest. Such a strategy was applied and evaluated for a complex, authentic, multisource, multiregion environment, including >2 years of data records from a system-evaluation exercise for the Defense Advanced Research Project Agency (DARPA). Multivariate and multiple univariate statistical process control methods were adapted and applied to the DARPA data collection. Comparative parametric analyses based on temporal aggregation were used to optimize the performance of these algorithms for timely detection of a set of outbreaks identified in the data by a team of epidemiologists. The sensitivity and timeliness of the most promising detection methods were tested at empirically calculated thresholds corresponding to multiple practical false-alert rates. Even at the strictest false-alert rate, all but one of the outbreaks were detected by the best method, and the best methods achieved a 1-day median time before alert over the set of test outbreaks. These results indicate that a biosurveillance system can provide a substantial alerting-timeliness advantage over traditional public health monitoring for certain outbreaks. Comparative analyses of individual algorithm results indicate further achievable improvement in sensitivity and specificity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stark, Eric J.
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. We tested one set of nine strobe lights flashing at a rate of 360 flashes/min in front of turbine 3 while operating at higher discharges than previously tested. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On five nights between January 31 andmore » February 28, 2006, when no lights were present, fish counts near turbine 3 averaged eight fish and densities averaged 91 fish/ha. When strobe lights were turned on during five adjacent nights during the same period, mean counts dropped to four fish and densities dropped to 35 fish/ha. The decline in counts (49%) was not statistically significant (p = 0.182), but decline in densities (62%) was significant (p = 0.049). There appeared to be no tendency for fish to habituate to the lights during the night. Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of turbines operating at higher discharges, which would be sufficient to improve sportfish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2005. Estimated abundance of kokanee decreased from the 2004 population estimate. Based on hydroacoustic surveys, we estimated 3,011,626 kokanee (90% CI {+-} 15.2%) in Dworshak Reservoir, July 2005. This included 2,135,986 age-0 (90% CI {+-} 15.9%), 769,175 age-1 (90% CI {+-} 16.0%), and 107,465 age-2 (90% CI {+-} 15.2%). Poor survival of kokanee from age-1 to age-2 continued to keep age-2 densities below the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site split-beam hydroacoustics a minimum of two days per month for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were again found during nighttime periods and lowest during the day. Fish detection rates were low during high discharges throughout the spring and summer and highest during low discharges in September and November. High discharge during drawdowns for anadromous fish flows in July and August again resulted in low detection rates and susceptibility to entrainment. Index counts of spawning kokanee in four tributary streams totaled 12,742 fish. This data fits the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
Monitoring Butterfly Abundance: Beyond Pollard Walks
Pellet, Jérôme; Bried, Jason T.; Parietti, David; Gander, Antoine; Heer, Patrick O.; Cherix, Daniel; Arlettaz, Raphaël
2012-01-01
Most butterfly monitoring protocols rely on counts along transects (Pollard walks) to generate species abundance indices and track population trends. It is still too often ignored that a population count results from two processes: the biological process (true abundance) and the statistical process (our ability to properly quantify abundance). Because individual detectability tends to vary in space (e.g., among sites) and time (e.g., among years), it remains unclear whether index counts truly reflect population sizes and trends. This study compares capture-mark-recapture (absolute abundance) and count-index (relative abundance) monitoring methods in three species (Maculinea nausithous and Iolana iolas: Lycaenidae; Minois dryas: Satyridae) in contrasted habitat types. We demonstrate that intraspecific variability in individual detectability under standard monitoring conditions is probably the rule rather than the exception, which questions the reliability of count-based indices to estimate and compare specific population abundance. Our results suggest that the accuracy of count-based methods depends heavily on the ecology and behavior of the target species, as well as on the type of habitat in which surveys take place. Monitoring programs designed to assess the abundance and trends in butterfly populations should incorporate a measure of detectability. We discuss the relative advantages and inconveniences of current monitoring methods and analytical approaches with respect to the characteristics of the species under scrutiny and resources availability. PMID:22859980
Self-Monitoring as an Intervention to Decrease Swimmers Stroke Counts
ERIC Educational Resources Information Center
Polaha, Jodi; Allen, Keith; Studley, Benjamin
2004-01-01
Self-monitoring of stroke count by swimmers is a common coaching strategy, it is but one that has little data to support it. Although research has demonstrated that self-monitoring can motivate behavior change, little research has focused on whether self-monitoring can enhance skill development. The purpose of the present set of studies was to…
Rain-induced increase in background radiation detected by Radiation Portal Monitors.
Livesay, R J; Blessinger, C S; Guzzardo, T F; Hausladen, P A
2014-11-01
A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to enhance partner country capability to deter, detect, and interdict the illicit movement of special nuclear material. In the present work, transient increases in gamma-ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates primarily from the wet-deposition of two radioactive daughters of (222)Rn, namely, (214)Pb and (214)Bi. In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and high-purity germanium spectra. The data verify that these radionuclides are responsible for the largest environmental background fluctuations in RPMs. Analytical expressions for the detector response function in Poly-Vinyl Toluene have been derived. Effects on system performance and potential mitigation strategies are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Using Tri-Axial Accelerometry in Daily Elite Swim Training Practice.
Ganzevles, Sander; Vullings, Rik; Beek, Peter Jan; Daanen, Hein; Truijens, Martin
2017-04-29
Background : Coaches in elite swimming carefully design the training programs of their swimmers and are keen on achieving strict adherence to those programs by their athletes. At present, coaches usually monitor the compliance of their swimmers to the training program with a stopwatch. However, this measurement clearly limits the monitoring possibilities and is subject to human error. Therefore, the present study was designed to examine the reliability and practical usefulness of tri-axial accelerometers for monitoring lap time, stroke count and stroke rate in swimming. Methods : In the first part of the study, a 1200 m warm-up swimming routine was measured in 13 elite swimmers using tri-axial accelerometers and synchronized video recordings. Reliability was determined using the typical error of measurement (TEM) as well as a Bland-Altman analysis. In the second part, training compliance both within and between carefully prescribed training sessions was assessed in four swimmers in order to determine the practical usefulness of the adopted accelerometric approach. In these sessions, targets were set for lap time and stroke count by the coach. Results : The results indicated high reliability for lap time (TEM = 0.26 s, bias = 0.74 [0.56 0.91] with limits of agreement (LoA) from -1.20 [-1.50 -0.90] to 2.70 [2.40 3.00]), stroke count (TEM 0.73 strokes, bias = 0.46 [0.32 0.60] with LoA from -1.70 [-1.94 -1.46] to 2.60 [2.36 2.84]) and stroke rate (TEM 0.72 str∙min -1 , bias = -0.13 [-0.20 -0.06] with LoA from -2.20 [-2.32 -2.08] to 1.90 [1.78 2.02]), while the results for the monitoring of training compliance demonstrated the practical usefulness of our approach in daily swimming training. Conclusions : The daily training of elite swimmers can be accurately and reliably monitored using tri-axial accelerometers. They provide the coach with more useful information to guide and control the training process than hand-clocked times.
Using Tri-Axial Accelerometry in Daily Elite Swim Training Practice
Ganzevles, Sander; Vullings, Rik; Beek, Peter Jan; Daanen, Hein; Truijens, Martin
2017-01-01
Background: Coaches in elite swimming carefully design the training programs of their swimmers and are keen on achieving strict adherence to those programs by their athletes. At present, coaches usually monitor the compliance of their swimmers to the training program with a stopwatch. However, this measurement clearly limits the monitoring possibilities and is subject to human error. Therefore, the present study was designed to examine the reliability and practical usefulness of tri-axial accelerometers for monitoring lap time, stroke count and stroke rate in swimming. Methods: In the first part of the study, a 1200 m warm-up swimming routine was measured in 13 elite swimmers using tri-axial accelerometers and synchronized video recordings. Reliability was determined using the typical error of measurement (TEM) as well as a Bland-Altman analysis. In the second part, training compliance both within and between carefully prescribed training sessions was assessed in four swimmers in order to determine the practical usefulness of the adopted accelerometric approach. In these sessions, targets were set for lap time and stroke count by the coach. Results: The results indicated high reliability for lap time (TEM = 0.26 s, bias = 0.74 [0.56 0.91] with limits of agreement (LoA) from −1.20 [−1.50 −0.90] to 2.70 [2.40 3.00]), stroke count (TEM 0.73 strokes, bias = 0.46 [0.32 0.60] with LoA from −1.70 [−1.94 −1.46] to 2.60 [2.36 2.84]) and stroke rate (TEM 0.72 str∙min−1, bias = −0.13 [−0.20 −0.06] with LoA from −2.20 [−2.32 −2.08] to 1.90 [1.78 2.02]), while the results for the monitoring of training compliance demonstrated the practical usefulness of our approach in daily swimming training. Conclusions: The daily training of elite swimmers can be accurately and reliably monitored using tri-axial accelerometers. They provide the coach with more useful information to guide and control the training process than hand-clocked times. PMID:28468255
2015-2016 Palila abundance estimates
Camp, Richard J.; Brinck, Kevin W.; Banko, Paul C.
2016-01-01
The palila (Loxioides bailleui) population was surveyed annually during 1998−2016 on Mauna Kea Volcano to determine abundance, population trend, and spatial distribution. In the latest surveys, the 2015 population was estimated at 852−1,406 birds (point estimate: 1,116) and the 2016 population was estimated at 1,494−2,385 (point estimate: 1,934). Similar numbers of palila were detected during the first and subsequent counts within each year during 2012−2016; the proportion of the total annual detections in each count ranged from 46% to 56%; and there was no difference in the detection probability due to count sequence. Furthermore, conducting repeat counts improved the abundance estimates by reducing the width of the confidence intervals between 9% and 32% annually. This suggests that multiple counts do not affect bird or observer behavior and can be continued in the future to improve the precision of abundance estimates. Five palila were detected on supplemental survey stations in the Ka‘ohe restoration area, outside the core survey area but still within Palila Critical Habitat (one in 2015 and four in 2016), suggesting that palila are present in habitat that is recovering from cattle grazing on the southwest slope. The average rate of decline during 1998−2016 was 150 birds per year. Over the 18-year monitoring period, the estimated rate of change equated to a 58% decline in the population.
Daily step count predicts acute exacerbations in a US cohort with COPD.
Moy, Marilyn L; Teylan, Merilee; Weston, Nicole A; Gagnon, David R; Garshick, Eric
2013-01-01
COPD is characterized by variability in exercise capacity and physical activity (PA), and acute exacerbations (AEs). Little is known about the relationship between daily step count, a direct measure of PA, and the risk of AEs, including hospitalizations. In an observational cohort study of 169 persons with COPD, we directly assessed PA with the StepWatch Activity Monitor, an ankle-worn accelerometer that measures daily step count. We also assessed exercise capacity with the 6-minute walk test (6MWT) and patient-reported PA with the St. George's Respiratory Questionnaire Activity Score (SGRQ-AS). AEs and COPD-related hospitalizations were assessed and validated prospectively over a median of 16 months. Mean daily step count was 5804±3141 steps. Over 209 person-years of observation, there were 263 AEs (incidence rate 1.3±1.6 per person-year) and 116 COPD-related hospitalizations (incidence rate 0.56±1.09 per person-year). Adjusting for FEV1 % predicted and prednisone use for AE in previous year, for each 1000 fewer steps per day walked at baseline, there was an increased rate of AEs (rate ratio 1.07; 95%CI = 1.003-1.15) and COPD-related hospitalizations (rate ratio 1.24; 95%CI = 1.08-1.42). There was a significant linear trend of decreasing daily step count by quartiles and increasing rate ratios for AEs (P = 0.008) and COPD-related hospitalizations (P = 0.003). Each 30-meter decrease in 6MWT distance was associated with an increased rate ratio of 1.07 (95%CI = 1.01-1.14) for AEs and 1.18 (95%CI = 1.07-1.30) for COPD-related hospitalizations. Worsening of SGRQ-AS by 4 points was associated with an increased rate ratio of 1.05 (95%CI = 1.01-1.09) for AEs and 1.10 (95%CI = 1.02-1.17) for COPD-related hospitalizations. Lower daily step count, lower 6MWT distance, and worse SGRQ-AS predict future AEs and COPD-related hospitalizations, independent of pulmonary function and previous AE history. These results support the importance of assessing PA in patients with COPD, and provide the rationale to promote PA as part of exacerbation-prevention strategies.
Hematology of healthy Florida manatees (Trichechus manatus).
Harvey, John W; Harr, Kendal E; Murphy, David; Walsh, Michael T; Nolan, Elizabeth C; Bonde, Robert K; Pate, Melanie G; Deutsch, Charles J; Edwards, Holly H; Clapp, William L
2009-06-01
Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals.
Cundell, A M; Bean, R; Massimore, L; Maier, C
1998-01-01
To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.
Establishing a gold standard for manual cough counting: video versus digital audio recordings
Smith, Jaclyn A; Earis, John E; Woodcock, Ashley A
2006-01-01
Background Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. Methods We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. Results The median cough frequency was 17.8 (IQR 5.9–28.7) cough sounds per hour in the video recordings and 17.7 (6.0–29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD ± 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2–4 hours of analysis per recording. Conclusion Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment. PMID:16887019
Kallio, Markku J. T.; Kallio, Pentti E.; Peltola, Heikki
2009-01-01
In addition to the examination of clinical signs, several laboratory markers have been measured for diagnostics and monitoring of pediatric septic bone and joint infections. Traditionally erythrocyte sedimentation rate (ESR) and leukocyte cell count have been used, whereas C-reactive protein (CRP) has gained in popularity. We monitored 265 children at ages 3 months to 15 years with culture-positive osteoarticular infections with a predetermined series of ESR, CRP, and leukocyte count measurements. On admission, ESR exceeded 20 mm/hour in 94% and CRP exceeded 20 mg/L in 95% of the cases, the mean (± standard error of the mean) being 51 ± 2 mm/hour and 87 ± 4 mg/L, respectively. ESR normalized in 24 days and CRP in 10 days. Elevated CRP gave a slightly better sensitivity in diagnostics than ESR, but best sensitivity was gained with the combined use of ESR and CRP (98%). Elevated ESR or CRP was seen in all cases during the first 3 days. Measuring ESR and CRP on admission can help the clinician rule out an acute osteoarticular infection. CRP normalizes faster than ESR, providing a clear advantage in monitoring recovery. Level of Evidence: Level II, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence. PMID:19533263
T Cell Lipid Rafts and Complement Ligands for Diagnosis and Monitoring of SLE
2011-05-01
including complete blood count, erythrocyte sedimentation rate , serum levels of C3 and C4, antinuclear autoantibodies (ANA), and anti-dsDNA level. Tests... sedimentation rate , serum levels of C3 and C4, antinuclear autoantibody (ANA) and anti-dsDNA antibody levels. In addition, each patient underwent history...6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER E-Mail: 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES
Gaglani, Shiv; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele
2015-01-01
Objectives: This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. Methods: This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Results: Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. Conclusions: These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested. PMID:26719825
Gaglani, Shiv; Moore, Jessica; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele
2015-11-17
This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested.
Swift/BAT confirms the giant outburst of H 1417-624
NASA Astrophysics Data System (ADS)
Krimm, H. A.; Barthelmy, S. D.; Cummings, J. R.; Lien, A. Y.; Markwardt, C. B.; Palmer, D. M.; Sakamoto, T.; Stamatikos, M.; Ukwatta, T. N.
2018-04-01
The Swift/BAT transient monitor confirms the current outburst from the Be/X-ray binary pulsar, H 1417-624 ( = 2S 1417-624) (Nakajima et al., ATel #11479). In the BAT 15-50 keV energy band, the outburst began approximately on 20 March 2018 (MJD 57467) and the count rate has been steadily rising since that time.
Swift/BAT sees MAXI J1535-571 declining in 15-50 keV
NASA Astrophysics Data System (ADS)
Palmer, D. M.; Krimm, H. A.; Swift/BAT Team
2017-09-01
BAT monitoring of MAXI J1535-571 shows that, in the 15-50 keV band, the source reached a peak around 2017 Sept 9 and has since begun to decline. At peak, the BAT count rate was 0.43 +/- 0.015 ct s-1 cm-2, or approximately twice the mean flux of the Crab.
Design of a spreader bar crane-mounted gamma-ray radiation detection system
NASA Astrophysics Data System (ADS)
Grypp, Matthew D.; Marianno, Craig M.; Poston, John W.; Hearn, Gentry C.
2014-04-01
Over 95% of imports entering the United States from outside North America arrive by sea at 329 ports of entry. These imports are packaged in more than 11 million cargo containers. Radiation portals monitors routinely scan cargo containers leaving port on specially-designed trucks. To accelerate the process, some commercial entities have placed detection systems on the spreader-bar cranes (SBCs) used to offload. Little is known about the radiation background profiles of systems operating on these cranes. To better understand the operational characteristics of these radiation detection systems; a research team from Texas A&M University (TAMU) mounted three thallium-doped sodium iodide [NaI(Tl)] detectors on an SBC at the Domestic Nuclear Detection Office's (DNDO) test track facility at the Port of Tacoma (PoT). These detectors were used to monitor background radiation levels and continuously recorded data during crane operations using a custom-built software package. Count rates and spectral data were recorded for various crane heights over both land and water. The results of this research created a background profile in which count rate was heavily dependent on position demonstrating how detector readings changed in the operational environment.
NASA Astrophysics Data System (ADS)
Memon, Sanober F.; Lewis, Elfed; Pembroke, J. Tony; Chowdhry, Bhawani S.
2017-04-01
A novel, low cost and highly sensitive optical fibre probe sensor for concentration measurement of ethanol solvent (C2H5OH) corresponding to bio-ethanol production rate by an algae is reported. The principle of operation of the sensor is based on inter-fibre light coupling through an evanescent field interaction to couple the light between two multimode fibres mounted parallel to each other at a minimum possible separation i.e. < 1mm. The sensor was fabricated using a low cost 1000um plastic optical fibre (POF) and was characterized for real time measurement in the broadband spectrum including visible and near infra-red. The wavelength dependency of this sensor design was also investigated by post processing analysis of real time data and hence the optimum wavelength range determined. The proposed sensor has shown significant response in the range of 0.005 - 0.1 %v/v (%volume/volume or volume concentration) which depicts the high sensitivity for monitoring very minute changes in concentration corresponding refractive index changes of the solution. Numerically, sensor has shown the sensitivity of 21945 intensity counts/%v/v or 109.7 counts per every 0.0050 %v/v.
Bui, Thuy-Vy D.; Takekawa, John Y.; Overton, Cory T.; Schultz, Emily R.; Hull, Joshua M.; Casazza, Michael L.
2015-01-01
The California Ridgway's rail Rallus obsoletus obsoletus (hereafter California rail) is a secretive marsh bird endemic to tidal marshes in the San Francisco Bay (hereafter bay) of California. The California rail has undergone significant range contraction and population declines due to a variety of factors, including predation and the degradation and loss of habitat. Call-count surveys, which include call playbacks, based on the standardized North American marsh bird monitoring protocol have been conducted throughout the bay since 2005 to monitor population size and distribution of the California rail. However, call-count surveys are difficult to evaluate for efficacy or accuracy. To measure the accuracy of call-count surveys and investigate whether radio-marked California rails moved in response to call-count surveys, we compared locations of radio-marked California rails collected at frequent intervals (15 min) to California rail detections recorded during call-count surveys conducted over the same time periods. Overall, 60% of radio-marked California rails within 200 m of observers were not detected during call-count surveys. Movements of radio-marked California rails showed no directional bias (P = 0.92) irrespective of whether or not playbacks of five marsh bird species (including the California rail) were broadcast from listening stations. Our findings suggest that playbacks of rail vocalizations do not consistently influence California rail movements during surveys. However, call-count surveys may underestimate California rail presence; therefore, caution should be used when relating raw numbers of call-count detections to population abundance.
Precision wildlife monitoring using unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Hodgson, Jarrod C.; Baylis, Shane M.; Mott, Rowan; Herrod, Ashley; Clarke, Rohan H.
2016-03-01
Unmanned aerial vehicles (UAVs) represent a new frontier in environmental research. Their use has the potential to revolutionise the field if they prove capable of improving data quality or the ease with which data are collected beyond traditional methods. We apply UAV technology to wildlife monitoring in tropical and polar environments and demonstrate that UAV-derived counts of colony nesting birds are an order of magnitude more precise than traditional ground counts. The increased count precision afforded by UAVs, along with their ability to survey hard-to-reach populations and places, will likely drive many wildlife monitoring projects that rely on population counts to transition from traditional methods to UAV technology. Careful consideration will be required to ensure the coherence of historic data sets with new UAV-derived data and we propose a method for determining the number of duplicated (concurrent UAV and ground counts) sampling points needed to achieve data compatibility.
Detecting trends in raptor counts: power and type I error rates of various statistical tests
Hatfield, J.S.; Gould, W.R.; Hoover, B.A.; Fuller, M.R.; Lindquist, E.L.
1996-01-01
We conducted simulations that estimated power and type I error rates of statistical tests for detecting trends in raptor population count data collected from a single monitoring site. Results of the simulations were used to help analyze count data of bald eagles (Haliaeetus leucocephalus) from 7 national forests in Michigan, Minnesota, and Wisconsin during 1980-1989. Seven statistical tests were evaluated, including simple linear regression on the log scale and linear regression with a permutation test. Using 1,000 replications each, we simulated n = 10 and n = 50 years of count data and trends ranging from -5 to 5% change/year. We evaluated the tests at 3 critical levels (alpha = 0.01, 0.05, and 0.10) for both upper- and lower-tailed tests. Exponential count data were simulated by adding sampling error with a coefficient of variation of 40% from either a log-normal or autocorrelated log-normal distribution. Not surprisingly, tests performed with 50 years of data were much more powerful than tests with 10 years of data. Positive autocorrelation inflated alpha-levels upward from their nominal levels, making the tests less conservative and more likely to reject the null hypothesis of no trend. Of the tests studied, Cox and Stuart's test and Pollard's test clearly had lower power than the others. Surprisingly, the linear regression t-test, Collins' linear regression permutation test, and the nonparametric Lehmann's and Mann's tests all had similar power in our simulations. Analyses of the count data suggested that bald eagles had increasing trends on at least 2 of the 7 national forests during 1980-1989.
Designing and implementing a monitoring program and the standards for conducting point counts
C. John Ralph
1993-01-01
Choosing between the apparent plethora of methods for monitoring bird populations is a dilemma for a person contemplating beginning a monitoring program. Cooperrider et al. (1986) and Koskimies and Vaisanen (1991) describe many methods. In the Americas, three methods have been suggested as standard (Butcher 1992). They are: point counts for determining habitat...
Controlling Hay Fever Symptoms with Accurate Pollen Counts
... counts Share | Controlling Hay Fever Symptoms with Accurate Pollen Counts Seasonal allergic rhinitis known as hay fever is ... hay fever symptoms, it is important to monitor pollen counts so you can limit your exposure on days ...
Crooks, Michael G; den Brinker, Albertus; Hayman, Yvette; Williamson, James D; Innes, Andrew; Wright, Caroline E; Hill, Peter; Morice, Alyn H
2017-06-01
Cough is common in chronic obstructive pulmonary disease (COPD) and is associated with frequent exacerbations and increased mortality. Cough increases during acute exacerbations (AE-COPD), representing a possible metric of clinical deterioration. Conventional cough monitors accurately report cough counts over short time periods. We describe a novel monitoring system which we used to record cough continuously for up to 45 days during AE-COPD convalescence. This is a longitudinal, observational study of cough monitoring in AE-COPD patients discharged from a single teaching hospital. Ambient sound was recorded from two sites in the domestic environment and analysed using novel cough classifier software. For comparison, the validated hybrid HACC/LCM cough monitoring system was used on days 1, 5, 20 and 45. Patients were asked to record symptoms daily using diaries. Cough monitoring data were available for 16 subjects with a total of 568 monitored days. Daily cough count fell significantly from mean ± SEM 272.7 ± 54.5 on day 1 to 110.9 ± 26.3 on day 9 (p < 0.01) before plateauing. The absolute cough count detected by the continuous monitoring system was significantly lower than detected by the hybrid HACC/LCM system but normalised counts strongly correlated (r = 0.88, p < 0.01) demonstrating an ability to detect trends. Objective cough count and subjective cough scores modestly correlated (r = 0.46). Cough frequency declines significantly following AE-COPD and the reducing trend can be detected using continuous ambient sound recording and novel cough classifier software. Objective measurement of cough frequency has the potential to enhance our ability to monitor the clinical state in patients with COPD.
Validity of Activity Monitor Step Detection Is Related to Movement Patterns.
Hickey, Amanda; John, Dinesh; Sasaki, Jeffer E; Mavilia, Marianna; Freedson, Patty
2016-02-01
There is a need to examine step-counting accuracy of activity monitors during different types of movements. The purpose of this study was to compare activity monitor and manually counted steps during treadmill and simulated free-living activities and to compare the activity monitor steps to the StepWatch (SW) in a natural setting. Fifteen participants performed laboratory-based treadmill (2.4, 4.8, 7.2 and 9.7 km/h) and simulated free-living activities (eg, cleaning room) while wearing an activPAL, Omron HJ720-ITC, Yamax Digi- Walker SW-200, 2 ActiGraph GT3Xs (1 in "low-frequency extension" [AGLFE] and 1 in "normal-frequency" mode), an ActiGraph 7164, and a SW. Participants also wore monitors for 1-day in their free-living environment. Linear mixed models identified differences between activity monitor steps and the criterion in the laboratory/free-living settings. Most monitors performed poorly during treadmill walking at 2.4 km/h. Cleaning a room had the largest errors of all simulated free-living activities. The accuracy was highest for forward/rhythmic movements for all monitors. In the free-living environment, the AGLFE had the largest discrepancy with the SW. This study highlights the need to verify step-counting accuracy of activity monitors with activities that include different movement types/directions. This is important to understand the origin of errors in step-counting during free-living conditions.
Hematology of healthy Florida manatees (Trichechus manatus)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.
2009-01-01
Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.
Shin, Young-San; Wee, Jae-Kyung; Song, Inchae; Lee, Seongsoo
2015-01-01
Heart rate monitoring is useful to detect many cardiovascular diseases. It can be implemented in a small device with low power consumption, and it can exploit low-cost piezoelectric pressure sensors to measure heart rate. However, it is also desirable to transmit heartbeat waveform for emergency treatment, which significantly increases transmission power. In this paper, a low-cost wireless heart condition monitoring SoC is proposed. It can monitor and transmit both heart rate and heartbeat waveform, but the hardware is extremely simplified to achieve in a small package. By slight modification of successive-approximation analog-digital converter, it can count heart rate and read out heartbeat waveform with the same hardware. In the normal mode, only an 8-bit heart rate is transmitted for power reduction. If the heart rate is out of a given range, it goes to the emergency mode and a 10-bit heartbeat waveform is transmitted for fast treatment. The fabricated chip size is 1.1 mm2 in 0.11 μ m CMOS technology, including the radio-frequency transmitter. The measured power consumption is 161.8 μ W in normal mode and 507.3 μ W in emergency mode, respectively. The proposed SoC achieves low-cost, small area, and low-power. It is useful as part of a disposable healthcare system.
Data acquisition system for phase-2 KGF proton decay experiment
NASA Technical Reports Server (NTRS)
Krishnaswamy, M. R.; Menon, M. G. K.; Mondal, N. K.; Narasimham, V. S.; Sreekantan, B. V.; Hayashi, Y.; Ito, N.; Kawakami, S.; Miyake, S.
1985-01-01
Phase-2 of KGF proton decay experiment using 4000 proportional counters will start operating from middle of 1985. The detection systems, in addition to measuring the time information to an accuracy of 200 n see, also records ionization in the hit counters. It also monitors different characteristics of the counters like pulse height spectrum, pulse width spectrum and counting rate. The acquisition system is discussed.
Gerber, Brian D.; Kendall, William L.
2017-01-01
Monitoring animal populations can be difficult. Limited resources often force monitoring programs to rely on unadjusted or smoothed counts as an index of abundance. Smoothing counts is commonly done using a moving-average estimator to dampen sampling variation. These indices are commonly used to inform management decisions, although their reliability is often unknown. We outline a process to evaluate the biological plausibility of annual changes in population counts and indices from a typical monitoring scenario and compare results with a hierarchical Bayesian time series (HBTS) model. We evaluated spring and fall counts, fall indices, and model-based predictions for the Rocky Mountain population (RMP) of Sandhill Cranes (Antigone canadensis) by integrating juvenile recruitment, harvest, and survival into a stochastic stage-based population model. We used simulation to evaluate population indices from the HBTS model and the commonly used 3-yr moving average estimator. We found counts of the RMP to exhibit biologically unrealistic annual change, while the fall population index was largely biologically realistic. HBTS model predictions suggested that the RMP changed little over 31 yr of monitoring, but the pattern depended on assumptions about the observational process. The HBTS model fall population predictions were biologically plausible if observed crane harvest mortality was compensatory up to natural mortality, as empirical evidence suggests. Simulations indicated that the predicted mean of the HBTS model was generally a more reliable estimate of the true population than population indices derived using a moving 3-yr average estimator. Practitioners could gain considerable advantages from modeling population counts using a hierarchical Bayesian autoregressive approach. Advantages would include: (1) obtaining measures of uncertainty; (2) incorporating direct knowledge of the observational and population processes; (3) accommodating missing years of data; and (4) forecasting population size.
Monitoring of HIV treatment in seven countries in the WHO Region of the Americas
Belaunzarán-Zamudio, Pablo F; Shepherd, Bryan E; Crabtree-Ramírez, Brenda E; Luz, Paula M; Grinsztejn, Beatriz; Cesar, Carina; Cahn, Pedro; Cortés, Claudia; Wolff, Marcelo; Pape, Jean W; Padgett, Denis; Gotuzzo, Eduardo; McGowan, Catherine; Sierra-Madero, Juan G
2015-01-01
Abstract Objective To determine the prevalence of adequate monitoring and the costs of measuring CD4+ T-lymphocytes (CD4+ cell) and human immunodeficiency virus (HIV) viral load in people receiving antiretroviral therapy (ART) in seven countries in the WHO Region of the Americas. Methods We obtained retrospective, longitudinal data for 14 476 adults who started a first ART regimen at seven HIV clinics in Argentina, Brazil, Chile, Haiti, Honduras, Mexico and Peru between 2000 and 2011. We estimated the proportion of 180-day periods with adequate monitoring, which we defined as at least one CD4+ cell count and one viral load measurement. Factors associated with adequate monitoring were analysed using regression methods. The costs of the tests were estimated. Findings The median follow-up time was 50.4 months; the proportion of 180-day periods with adequate CD4+ cell counts was 69% while the proportion with adequate monitoring was 62%. Adequate monitoring was more likely in participants who were older, who started ART more recently, whose first regimen included a non-nucleoside reverse transcriptase inhibitor or who had a CD4+ cell count less than 200 cells/µl at ART initiation. The cost of one CD4+ cell count ranged from 7.37 United States dollars (US$) in Argentina to US$ 64.09 in Chile; the cost of one viral load measurement ranged from US$ 20.34 in Brazil to US$ 186.28 in Haiti. Conclusion In HIV-infected participants receiving ART in the WHO Region of the Americas, CD4+ cell count and viral load monitoring was often carried out less frequently than regional guidelines recommend. The laboratory costs of monitoring varied greatly. PMID:26478610
Monitoring of HIV treatment in seven countries in the WHO Region of the Americas.
Belaunzarán-Zamudio, Pablo F; Caro-Vega, Yanink N; Shepherd, Bryan E; Crabtree-Ramírez, Brenda E; Luz, Paula M; Grinsztejn, Beatriz; Cesar, Carina; Cahn, Pedro; Cortés, Claudia; Wolff, Marcelo; Pape, Jean W; Padgett, Denis; Gotuzzo, Eduardo; McGowan, Catherine; Sierra-Madero, Juan G
2015-08-01
To determine the prevalence of adequate monitoring and the costs of measuring CD4+ T-lymphocytes (CD4+ cell) and human immunodeficiency virus (HIV) viral load in people receiving antiretroviral therapy (ART) in seven countries in the WHO Region of the Americas. We obtained retrospective, longitudinal data for 14 476 adults who started a first ART regimen at seven HIV clinics in Argentina, Brazil, Chile, Haiti, Honduras, Mexico and Peru between 2000 and 2011. We estimated the proportion of 180-day periods with adequate monitoring, which we defined as at least one CD4+ cell count and one viral load measurement. Factors associated with adequate monitoring were analysed using regression methods. The costs of the tests were estimated. The median follow-up time was 50.4 months; the proportion of 180-day periods with adequate CD4+ cell counts was 69% while the proportion with adequate monitoring was 62%. Adequate monitoring was more likely in participants who were older, who started ART more recently, whose first regimen included a non-nucleoside reverse transcriptase inhibitor or who had a CD4+ cell count less than 200 cells/µl at ART initiation. The cost of one CD4+ cell count ranged from 7.37 United States dollars (US$) in Argentina to US$ 64.09 in Chile; the cost of one viral load measurement ranged from US$ 20.34 in Brazil to US$ 186.28 in Haiti. In HIV-infected participants receiving ART in the WHO Region of the Americas, CD4+ cell count and viral load monitoring was often carried out less frequently than regional guidelines recommend. The laboratory costs of monitoring varied greatly.
Reduction of Energy Intake using Just-In-Time Feedback from a Wearable Sensor System
Farooq, Muhammad; McCrory, Megan A.; Sazonov, Edward
2017-01-01
Objective This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Methods Eighteen participants each consumed three meals in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits during which the target chew counts was either the same as that at baseline or the baseline chew counts reduced by 25%, in randomized order. The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVA were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across 3 meals. Results JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. Conclusion JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide just-in-time adaptive interventions for reducing energy intake. PMID:28233942
Reduction of energy intake using just-in-time feedback from a wearable sensor system.
Farooq, Muhammad; McCrory, Megan A; Sazonov, Edward
2017-04-01
This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Eighteen participants consumed three meals each in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits, during which the target chew count was either the same as that at baseline or the baseline chew count reduced by 25% (in randomized order). The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVAs were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across three meals. JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide JIT adaptive interventions for reducing energy intake. © 2017 The Obesity Society.
Assessing avian richness in remnant wetlands: Towards an improved methodology
Krzys, Greg; Waite, Thomas A.; Stapanian, Martin; Vucetich, John A.
2002-01-01
Because the North American Breeding Bird Survey provides inadequate coverage of wetland habitat, the Wetland Breeding Bird Survey was recently established in Ohio, USA. This program relies on volunteers to conduct 3 counts at each monitored wetland. Currently, all counts are conducted during the morning. Under the premise that volunteer participation could be increased by allowing evening counts, we evaluated the potential for modifying the methodology. We evaluated the sampling efficiency of all 3-count combinations of morning and evening counts using data collected at 14 wetlands. Estimates of overall species richness decreased with increasing numbers of evening counts. However, this pattern did not hold when analyses were restricted to wetland-dependent species or those of conservation concern. Our findings suggest that it would be reasonable to permit evening counts, particularly if the data are to be used to monitor wetland dependent species and those of concern.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jammes, C.; Filliatre, P.; Izarra, G. de
France has a long experience of about 50 years in designing, building and operating sodium-cooled fast reactors (SFR) such as RAPSODIE, PHENIX and SUPER PHENIX. Fast reactors feature the double capability of reducing nuclear waste and saving nuclear energy resources by burning actinides. Since this reactor type is one of those selected by the Generation IV International Forum, the French government asked, in the year 2006, CEA, namely the French Alternative Energies and Atomic Energy Commission, to lead the development of an innovative GEN-IV nuclear- fission power demonstrator. The major objective is to improve the safety and availability of anmore » SFR. The neutron flux monitoring (NFM) system of any reactor must, in any situation, permit both reactivity control and power level monitoring from startup to full power. It also has to monitor possible changes in neutron flux distribution within the core region in order to prevent any local melting accident. The neutron detectors will have to be installed inside the reactor vessel because locations outside the vessel will suffer from severe disadvantages; radially the neutron shield that is also contained in the reactor vessel will cause unacceptable losses in neutron flux; below the core the presence of a core-catcher prevents from inserting neutron guides; and above the core the distance is too large to obtain decent neutron signals outside the vessel. Another important point is to limit the number of detectors placed in the vessel in order to alleviate their installation into the vessel. In this paper, we show that the architecture of the NFM system will rely on high-temperature fission chambers (HTFC) featuring wide-range flux monitoring capability. The definition of such a system is presented and the justifications of technological options are brought with the use of simulation and experimental results. Firstly, neutron-transport calculations allow us to propose two in-vessel regions, namely the above-core and under-core structures. We verify that they comply with the main objective, that is the neutron power and flux distribution monitoring. HTFC placed in these two regions can detect an inadvertent control rod withdrawal that is a postulated initiating event for safety demonstration. Secondly, we show that the HTFC reliability is enhanced thanks to a more robust physical design and the fact that it has been justified that the mineral insulation is insensitive to any increase in temperature. Indeed, the HTFC insulation is subject to partial discharges at high temperature when the electric field between their electrodes is greater than about 200 V/mm or so. These discharges give rise to signals similar to the neutron pulses generated by a fission chamber itself, which may bias the HTFC count rate at start-up only. However, as displayed in Figure 1, we have experimentally verified that one can discriminate neutron pulses from partial discharges using online estimation of pulse width. Thirdly, we propose to estimate the count rate of a HTFC using the third order cumulant of its signal that is described by a filtered Poisson process. For such a statistic process, it is known that any cumulant, also called cumulative moment, is proportional to the process intensity that is here the count rate of a fission chamber. One recalls that the so-called Campbelling mode of such a detector is actually based on the signal variance, which is the second-order cumulant as well. The use of this extended Campbelling mode based on the third-order cumulant will permit to ensure the HTFC response linearity over the entire neutron flux range using a signal processing technique that is simple enough to satisfy design constraints on electric devices important for nuclear safety. We also show that this technique, named high order Campbelling method (HOC), is significantly more robust than another technique based on the change in the HTFC filling gas, which consists in adding a few percent of nitrogen. Finally, we also present an experimental campaign devoted to the required calibration process of the so-called HOC method. The Campbelling results show a good agreement with the simple pulse counting estimation at low count rates. It is also shown that the HOC technique provides a linear estimation of the count rates at higher power levels as well.« less
Patino, Mario; Kalin, Megan; Griffin, Allison; Minhajuddin, Abu; Ding, Lili; Williams, Timothy; Ishman, Stacey; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter
2017-06-01
In children, postoperative respiratory rate (RR) monitoring by transthoracic impedance (TI), capnography, and manual counting has limitations. The rainbow acoustic monitor (RAM) measures continuous RR noninvasively by a different methodology. Our primary aim was to compare the degree of agreement and accuracy of RR measurements as determined by RAM and TI to that of manual counting. Secondary aims include tolerance and analysis of alarm events. Sixty-two children (2-16 years old) were admitted after tonsillectomy or receiving postoperative patient/parental-controlled analgesia. RR was measured at regular intervals by RAM, TI, and manual count. Each TI or RAM alarm resulted in a clinical evaluation to categorize as a true or false alarm. To assess accuracy and degree of agreement of RR measured by RAM or TI compared with manual counting, a Bland-Altman analysis was utilized showing the average difference and the limits of agreement. Sensitivity and specificity of RR alarms by TI and RAM are presented. Fifty-eight posttonsillectomy children and 4 patient/parental-controlled analgesia users aged 6.5 ± 3.4 years and weighting 35.3 ± 22.7 kg (body mass index percentile 76.6 ± 30.8) were included. The average monitoring time per patient was 15.9 ± 4.8 hours. RAM was tolerated 87% of the total monitoring time. The manual RR count was significantly different from TI (P = .007) with an average difference ± SD of 1.39 ± 10.6 but were not significantly different from RAM (P = .81) with an average difference ± SD of 0.17 ± 6.8. The proportion of time when RR measurements differed by ≥4 breaths was 22% by TI and was 11% by RAM. Overall, 276 alarms were detected (mean alarms/patient = 4.5). The mean number of alarms per patient were 1.58 ± 2.49 and 2.87 ± 4.32 for RAM and TI, respectively. The mean number of false alarms was 0.18 ± 0.71 for RAM and 1.00 ± 2.78 for TI. The RAM was found to have 46.6% sensitivity (95% confidence interval [CI], 0.29-0.64), 95.9% specificity (95% CI, 0.90-1.00), 88.9% positive predictive value (95% CI, 0.73-1.00), and 72.1% negative predictive value (95% CI, 0.61-0.84), whereas the TI monitor had 68.5% sensitivity (95% CI, 0.53-0.84), 72.0% specificity (95% CI, 0.60-0.84), 59.0% positive (95% CI, 0.44-0.74), and 79.5% negative predictive value (95% CI, 0.69-0.90). In children at risk of postoperative respiratory depression, RR assessment by RAM was not different to manual counting. RAM was well tolerated, had a lower incidence of false alarms, and had better specificity and positive predictive value than TI. Rigorous evaluation of the negative predictive value is essential to determine the role of postoperative respiratory monitoring with RAM.
Subenthiran, Soobitha; Choon, Tan Chwee; Cheong, Kee Chee; Thayan, Ravindran; Teck, Mok Boon; Muniandy, Prem Kumar; Afzan, Adlin; Abdullah, Noor Rain; Ismail, Zakiah
2013-01-01
The study was conducted to investigate the platelet increasing property of Carica papaya leaves juice (CPLJ) in patients with dengue fever (DF). An open labeled randomized controlled trial was carried out on 228 patients with DF and dengue haemorrhagic fever (DHF). Approximately half the patients received the juice, for 3 consecutive days while the others remained as controls and received the standard management. Their full blood count was monitored 8 hours for 48 hours. Gene expression studies were conducted on the ALOX 12 and PTAFR genes. The mean increase in platelet counts were compared in both groups using repeated measure ANCOVA. There was a significant increase in mean platelet count observed in the intervention group (P < 0.001) but not in the control group 40 hours since the first dose of CPLJ. Comparison of mean platelet count between intervention and control group showed that mean platelet count in intervention group was significantly higher than control group after 40 and 48 hours of admission (P < 0.01). The ALOX 12 (FC = 15.00) and PTAFR (FC = 13.42) genes were highly expressed among those on the juice. It was concluded that CPLJ does significantly increase the platelet count in patients with DF and DHF. PMID:23662145
Pandalaneni, K; Amamcharla, J K
2016-07-01
Lactose accounts for about 75 and 85% of the solids in whey and deproteinized whey, respectively. Production of lactose is usually carried out by a process called crystallization. Several factors including rate of cooling, presence of impurities, and mixing speed influence the crystal size characteristics. To optimize the lactose crystallization process parameters to maximize the lactose yield, it is important to monitor the crystallization process. However, efficient in situ tools to implement at concentrations relevant to the dairy industry are lacking. The objective of the present work was to use a focused beam reflectance measurement (FBRM) system for in situ monitoring of lactose crystallization at supersaturated concentrations (wt/wt) 50, 55, and 60% at 20 and 30°C. The FBRM data were compared with Brix readings collected using a refractometer during isothermal crystallization. Chord length distributions obtained from FBRM in the ranges of <50 µm (fine crystals) and 50 to 300 µm (coarse crystals) were recorded and evaluated in relation to the extent of crystallization and rate constants deduced from the refractometer measurements. Extent of crystallization and rate constants increased with increasing supersaturation concentration and temperature. The measured fine crystal counts from FBRM increased at higher supersaturated concentration and temperature during isothermal crystallization. On the other hand, coarse counts were observed to increase with decreasing supersaturated concentration and temperature. Square weighted chord length distribution obtained from FBRM showed that as concentration increased, a decrease in chord lengths occurred at 20°C and similar observations were made from microscopic images. The robustness of FBRM in understanding isothermal lactose crystallization at various concentrations and temperatures was successfully assessed in the study. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Horton, Kyle G; Shriver, W Gregory; Buler, Jeffrey J
2016-01-01
Daily magnitudes and fluxes of landbird migration are often measured via nocturnal traffic rates aloft or diurnal densities within terrestrial habitats during stopover. However, these measures are not consistently correlated and at times reveal opposing trends. For this reason we sought to determine how comparison methods (daily magnitude or daily flux), nocturnal monitoring tools (weather surveillance radar, WSR; thermal imaging, TI), and temporal scale (preceding or following diurnal sampling) influenced correlation strength from stopover densities estimated by daily transect counts. We quantified nocturnal traffic rates at two temporal scales; averaged across the entire night and within individual decile periods of the night, and at two spatial scales; within 1 km of airspace surrounding the site via WSR and directly overhead within the narrow beam of a TI. Overall, the magnitude of daily bird density during stopover was positively related to the magnitude of broad-scale radar traffic rates of migrants on preceding and following nights during both the spring and fall. These relationships were strongest on the following night, and particularly from measures early in the night. Only during the spring on the following nights did we find positive correlations between the daily flux of transect counts and migration traffic rates (both WSR and TI). This indicates that our site likely had a more consistent daily turnover of migrants compared to the fall. The lack of general correlations between seasonal trends or daily flux in fine-scale TI traffic rates and stopover densities across or within nights was unexpected and likely due to poor sampling of traffic rates due to the camera's narrow beam. The order (preceding or following day) and metric of comparisons (magnitude or flux), as well as the tool (WSR or TI) used for monitoring nocturnal migration traffic can have dramatic impacts when compared with ground-based estimates of migrant density. WSR provided measures of the magnitude and daily flux in nocturnal migration traffic rates that related to daily stopover counts of migrants during spring and fall. Relationships among migrating bird flux measures are more complex than simple measures of magnitude of migration. Care should be given to address these complexities when comparing data among methods.
South Atlantic Anomaly Entry and Exit as Measured by the X-Ray Timing Explorer
NASA Technical Reports Server (NTRS)
Smith, Evan; Stark, Michael; Giles, Barry; Antunes, Sandy; Gawne, Bill
1996-01-01
The Rossi X-ray Timing Explorer (RXTE) carries instruments that must switch off high voltages (HV) when passing through the South Atlantic Anomaly (SAA). The High Energy X-ray Timing Experiment (HEXTE) contains a particle monitor that detects the increased particle flux associated with the SAA and autonomously reduces its voltage. The Proportional Counter Array (PCA) relies on uplinked predictions of SAA entry/exit times based on ephemeris data provided by the Flight Dynamics Facility. A third instrument, the All-Sky Monitor (ASM) also uses a predicted SAA model to reduce voltage when passing through the SAA. Data collected from the HEXTE particle monitor, as well as other instrument readings near the times of SAA entry/exit offer the potential for refining models of the boundaries of the SAA. The SAA has an increased particle flux which causes high rates of detection in the RXTE instruments designed to observe x-rays. The high counting rates could degrade the PCA if HV is not reduced during SAA passages. On the other hand, PCA downtime can be minimized and the science return can be optimized by having the best possible model of the SAA boundary. Thus, the PCA team planned an extensive effort during in-orbit checkout to utilize both the HEXTE particle monitor data and instrument counting rates to refine the model of the SAA boundary. The times of SAA entry and exit are compared with the definitive epemeris to determine the precise location (latitude and longitude) of the SAA boundary. Over time, the SAA and its perimeter were mapped. The RXTE Science Operations Center is continuously working to feed back the results of this effort into the science scheduling process, improving the SAA model as it affects the RXTE instruments, thus obtaining more accurate estimates of the SAA entry/exit times.
Count-doubling time safety circuit
Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.
1981-01-01
There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.
Townsley, Hermaleigh; White, Bonnie; Langlotz, Tobias; Taylor, William J
2017-01-01
Background Rheumatoid arthritis (RA) is a chronic inflammatory arthritis requiring long-term treatment with regular monitoring by a rheumatologist to achieve good health outcomes. Since people with RA may wish to monitor their own disease activity with a smartphone app, it is important to understand the functions and quality of apps for this purpose. Objective The aim of our study was to assess the features and quality of apps to assist people to monitor their RA disease activity by (1) summarizing the available apps, particularly the instruments used for measurement of RA disease activity; (2) comparing the app features with American College of Rheumatology and European League against Rheumatism (ACR and EULAR) guidelines for monitoring of RA disease activity; and (3) rating app quality with the Mobile App Rating Scale (MARS). Methods Systematic searches of the New Zealand iTunes and Google Play app stores were used to identify all apps for monitoring of RA disease activity that could be used by people with RA. The apps were described by both key metadata and app functionality. App adherence with recommendations for monitoring of RA disease activity in clinical practice was evaluated by identifying whether apps included calculation of a validated composite disease activity measure and recorded results for future retrieval. App quality was assessed by 2 independent reviewers using the MARS. Results The search identified 721 apps in the Google Play store and 216 in the iTunes store, of which 19 unique apps met criteria for inclusion (8 from both app stores, 8 iTunes, and 3 Google Play). In total, 14 apps included at least one validated instrument measuring RA disease activity; 7 of 11 apps that allowed users to enter a joint count used the standard 28 swollen and tender joint count; 8 apps included at least one ACR and EULAR-recommended RA composite disease activity (CDA) measure; and 10 apps included data storage and retrieval. Only 1 app, Arthritis Power, included both an RA CDA measure and tracked data, but this app did not include the standard 28 tender and swollen joint count. The median overall MARS score for apps was 3.41/5. Of the 6 apps that scored ≥4/5 on the overall MARS rating, only 1 included a CDA score endorsed by ACR and EULAR; however, this app did not have a data tracking function. Conclusions This review found a lack of high-quality apps for longitudinal assessment of RA disease activity. Current apps fall into two categories: simple calculators primarily for rheumatologists and data tracking tools for people with RA. The latter do not uniformly collect data using validated instruments or composite disease activity measures. There is a need for appropriate, high-quality apps for use by rheumatologists and patients together in co-management of RA. PMID:28223263
Nilsen, Erlend B; Strand, Olav
2018-01-01
We developed a model for estimating demographic rates and population abundance based on multiple data sets revealing information about population age- and sex structure. Such models have previously been described in the literature as change-in-ratio models, but we extend the applicability of the models by i) using time series data allowing the full temporal dynamics to be modelled, by ii) casting the model in an explicit hierarchical modelling framework, and by iii) estimating parameters based on Bayesian inference. Based on sensitivity analyses we conclude that the approach developed here is able to obtain estimates of demographic rate with high precision whenever unbiased data of population structure are available. Our simulations revealed that this was true also when data on population abundance are not available or not included in the modelling framework. Nevertheless, when data on population structure are biased due to different observability of different age- and sex categories this will affect estimates of all demographic rates. Estimates of population size is particularly sensitive to such biases, whereas demographic rates can be relatively precisely estimated even with biased observation data as long as the bias is not severe. We then use the models to estimate demographic rates and population abundance for two Norwegian reindeer (Rangifer tarandus) populations where age-sex data were available for all harvested animals, and where population structure surveys were carried out in early summer (after calving) and late fall (after hunting season), and population size is counted in winter. We found that demographic rates were similar regardless whether we include population count data in the modelling, but that the estimated population size is affected by this decision. This suggest that monitoring programs that focus on population age- and sex structure will benefit from collecting additional data that allow estimation of observability for different age- and sex classes. In addition, our sensitivity analysis suggests that focusing monitoring towards changes in demographic rates might be more feasible than monitoring abundance in many situations where data on population age- and sex structure can be collected.
Validity of FitBit, Jawbone UP, Nike+ and other wearable devices for level and stair walking.
Huang, Yangjian; Xu, Junkai; Yu, Bo; Shull, Peter B
2016-07-01
Increased physical activity can provide numerous health benefits. The relationship between physical activity and health assumes reliable activity measurements including step count and distance traveled. This study assessed step count and distance accuracy for Nike+ FuelBand, Jawbone UP 24, Fitbit One, Fitbit Flex, Fitbit Zip, Garmin Vivofit, Yamax CW-701, and Omron HJ-321 during level, upstairs, and downstairs walking in healthy adults. Forty subjects walked on flat ground (400m), upstairs (176 steps), and downstairs (176 steps), and a subset of 10 subjects performed treadmill walking trials to assess the influence of walking speed on accuracy. Activity monitor measured step count and distance values were compared with actual step count (determined from video recordings) and distance to determine accuracy. For level walking, step count errors in Yamax CW-701, Fitbit Zip, Fitbit One, Omron HJ-321, and Jawbone UP 24 were within 1% and distance errors in Fitbit Zip and Yamax CW-701 were within 5%. Garmin Vivofit and Omron HJ-321 were the most accurate in estimating step count for stairs with errors less than 4%. An important finding is that all activity monitors overestimated distance for stair walking by at least 45%. In general, there were not accuracy differences among activity monitors for stair walking. Accuracy did not change between moderate and fast walking speeds, though slow walking increased errors for some activity monitors. Nike+ FuelBand was the least accurate step count estimator during all walking tasks. Caution should be taken when interpreting step count and distance estimates for activities involving stairs. Copyright © 2016 Elsevier B.V. All rights reserved.
Roy, Helen E; Baxter, Elizabeth; Saunders, Aoine; Pocock, Michael J O
2016-01-01
Recently there has been increasing focus on monitoring pollinating insects, due to concerns about their declines, and interest in the role of volunteers in monitoring pollinators, particularly bumblebees, via citizen science. The Big Bumblebee Discovery was a one-year citizen science project run by a partnership of EDF Energy, the British Science Association and the Centre for Ecology & Hydrology which sought to assess the influence of the landscape at multiple scales on the diversity and abundance of bumblebees. Timed counts of bumblebees (Bombus spp.; identified to six colour groups) visiting focal plants of lavender (Lavendula spp.) were carried out by about 13 000 primary school children (7-11 years old) from over 4000 schools across the UK. 3948 reports were received totalling 26 868 bumblebees. We found that while the wider landscape type had no significant effect on reported bumblebee abundance, the local proximity to flowers had a significant effect (fewer bumblebees where other flowers were reported to be >5m away from the focal plant). However, the rate of mis-identifcation, revealed by photographs uploaded by participants and a photo-based quiz, was high. Our citizen science results support recent research on the importance of local flocal resources on pollinator abundance. Timed counts of insects visiting a lure plant is potentially an effective approach for standardised pollinator monitoring, engaging a large number of participants with a simple protocol. However, the relatively high rate of mis-identifications (compared to reports from previous pollinator citizen science projects) highlights the importance of investing in resources to train volunteers. Also, to be a scientifically valid method for enquiry, citizen science data needs to be sufficiently high quality, so receiving supporting evidence (such as photographs) would allow this to be tested and for records to be verified.
Regression Analysis of Mixed Recurrent-Event and Panel-Count Data with Additive Rate Models
Zhu, Liang; Zhao, Hui; Sun, Jianguo; Leisenring, Wendy; Robison, Leslie L.
2015-01-01
Summary Event-history studies of recurrent events are often conducted in fields such as demography, epidemiology, medicine, and social sciences (Cook and Lawless, 2007; Zhao et al., 2011). For such analysis, two types of data have been extensively investigated: recurrent-event data and panel-count data. However, in practice, one may face a third type of data, mixed recurrent-event and panel-count data or mixed event-history data. Such data occur if some study subjects are monitored or observed continuously and thus provide recurrent-event data, while the others are observed only at discrete times and hence give only panel-count data. A more general situation is that each subject is observed continuously over certain time periods but only at discrete times over other time periods. There exists little literature on the analysis of such mixed data except that published by Zhu et al. (2013). In this paper, we consider the regression analysis of mixed data using the additive rate model and develop some estimating equation-based approaches to estimate the regression parameters of interest. Both finite sample and asymptotic properties of the resulting estimators are established, and the numerical studies suggest that the proposed methodology works well for practical situations. The approach is applied to a Childhood Cancer Survivor Study that motivated this study. PMID:25345405
Hypothesis tests for the detection of constant speed radiation moving sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir
2015-07-01
Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes amore » benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)« less
Sheffield, L.M.; Gall, Adrian E.; Roby, D.D.; Irons, D.B.; Dugger, K.M.
2006-01-01
Least Auklets (Aethia pusilla (Pallas, 1811)) are the most abundant species of seabird in the Bering Sea and offer a relatively efficient means of monitoring secondary productivity in the marine environment. Counting auklets on surface plots is the primary method used to track changes in numbers of these crevice-nesters, but counts can be highly variable and may not be representative of the number of nesting individuals. We compared average maximum counts of Least Auklets on surface plots with density estimates based on mark–resight data at a colony on St. Lawrence Island, Alaska, during 2001–2004. Estimates of breeding auklet abundance from mark–resight averaged 8 times greater than those from maximum surface counts. Our results also indicate that average maximum surface counts are poor indicators of breeding auklet abundance and do not vary consistently with auklet nesting density across the breeding colony. Estimates of Least Auklet abundance from mark–resight were sufficiently precise to meet management goals for tracking changes in seabird populations. We recommend establishing multiple permanent banding plots for mark–resight studies on colonies selected for intensive long-term monitoring. Mark–resight is more likely to detect biologically significant changes in size of auklet breeding colonies than traditional surface count techniques.
NASA Technical Reports Server (NTRS)
Iucci, N.; Parisi, M.; Signorini, C.; Storini, M.; Villoresi, G.
1985-01-01
On the occasion of the June 3, 1982 intense gamma-ray solar flare a significant increase in counting rate due to solar neutrons was observed by the neutron monitors of Junsfraujoch and Lomnicky Stit located at middle latitudes and high altitudes. In spite of a larger detector employed and of the smaller solar zenith angle, the amplitude of the same event observed at Rome was much smaller and the statistical fluctuations of the salactic cosmic ray background higher than the ones registered at the two mountain stations, because of the greater atmospheric depth at which the Rome monitor is located. The effeciency for detecting a solar neutron event by a NM-64 monitor as a function of the Sun zenith angle, atmospheric depth and threshold rigidity of the station was studied.
Link Performance Analysis and monitoring - A unified approach to divergent requirements
NASA Astrophysics Data System (ADS)
Thom, G. A.
Link Performance Analysis and real-time monitoring are generally covered by a wide range of equipment. Bit Error Rate testers provide digital link performance measurements but are not useful during real-time data flows. Real-time performance monitors utilize the fixed overhead content but vary widely from format to format. Link quality information is also present from signal reconstruction equipment in the form of receiver AGC, bit synchronizer AGC, and bit synchronizer soft decision level outputs, but no general approach to utilizing this information exists. This paper presents an approach to link tests, real-time data quality monitoring, and results presentation that utilizes a set of general purpose modules in a flexible architectural environment. The system operates over a wide range of bit rates (up to 150 Mbs) and employs several measurement techniques, including P/N code errors or fixed PCM format errors, derived real-time BER from frame sync errors, and Data Quality Analysis derived by counting significant sync status changes. The architecture performs with a minimum of elements in place to permit a phased update of the user's unit in accordance with his needs.
Ahn, Jin Young; Boettiger, David; Law, Matthew; Kumarasamy, Nagalingeswaran; Yunihastuti, Evy; Chaiwarith, Romanee; Lee, Man Po; Sim, Benedict LH; Oka, Shinichi; Wong, Wingwai; Kamarulzaman, Adeeba; Kantipong, Pacharee; Phanuphak, Praphan; Ng, Oon Tek; Kiertiburanakul, Sasisopin; Zhang, Fujie; Pujari, Sanjay; Ditangco, Rossana; Ratanasuwan, Winai; Merati, Tuti Parwati; Saphonn, Vonthanak; Sohn, Annette H.; Choi, Jun Yong
2015-01-01
Background Current treatment guidelines for HIV infection recommend routine CD4+ lymphocyte (CD4) count monitoring in patients with viral suppression. This may have a limited impact on influencing care as clinically meaningful CD4 decline rarely occurs during viral suppression. Methods In a regional HIV observational cohort in the Asia-Pacific, patients with viral suppression (2 consecutive viral loads <400 copies/mL) and a CD4 count ≥200 cells/μL who had CD4 testing 6 monthly were analyzed. Main study endpoints were occurrence of one CD4 count <200 cells/μL (single CD4<200) and two CD4 counts <200 cells/μL within a 6-month period (confirmed CD4<200). A comparison of time to single and confirmed CD4<200 with biannual or annual CD4 assessment was performed by generating a hypothetical group comprised of the same patients with annual CD4 testing by removing every second CD4 count. Results Among 1538 patients, the rate of single CD4<200 was 3.45/100 patient-years, and of confirmed CD4<200 was 0.77/100 patient-years. During 5 years of viral suppression, patients with baseline CD4 200-249 cells/μL were significantly more likely to experience confirmed CD4<200 compared with patients with higher baseline CD4 (hazard ratio 55.47 [95% confidence interval 7.36–418.20], p<0.001 versus baseline CD4 ≥500 cells/μL). Cumulative probabilities of confirmed CD4<200 was also higher in patients with baseline CD4 200-249 cells/μL compared with patients with higher baseline CD4. There was no significant difference in time to confirmed CD4<200 between biannual and annual CD4 measurement (p=0.336). Conclusions Annual CD4 monitoring in virally suppressed HIV patients with a baseline CD4 ≥250 cells/μL may be sufficient for clinical management. PMID:25850606
Nakanjako, Damalie; Kiragga, Agnes N.; Musick, Beverly S.; Yiannoutsos, Constantin T.; Wools-Kaloustian, Kara; Diero, Lameck; Oyaro, Patrick; Lugina, Emanuel; Ssali, John C.; Kambugu, Andrew; Easterbrook, Philippa
2017-01-01
Objective To describe patterns of suboptimal immune recovery (SO-IR) and associated HIV-related-illnesses during the first 5 years following first-line antiretroviral therapy (ART) initiation across seven ART sites in East Africa. Design Retrospective analysis of data from seven ART clinical sites (three Uganda, two Kenya and two Tanzania). Methods SO-IR was described by proportions of ART-treated adults with CD4+ cell counts less than 200, less than 350 and less than 500 cells/μl. Kaplan–Meier survival analysis techniques were used to assess predictors of SO-IR, and incident rates of HIV-related illnesses at CD4+ cell counts less than 200, 200–350, 351–499, and >500 cells/μl, respectively. Results Overall 80 843 adults initiated non-nucleoside reverse transcriptase inhibitor-based first-line ART; 65% were women and median CD4+ cell count was 126 [interquartile range (IQR), 52–202] cells/μl. Cumulative probability of SO-IR <200 cells/μl, <350 cells/μl and <500 cells/μl, after 5 years, was 11, 38 and 63%, respectively. Incidence of HIV-related illnesses was higher among those with CD4+ cell counts less than 200 and 200–350 cells/μl, than those who achieved CD4 counts above these thresholds. The most common events, at CD4 <200 cells/μl, were pulmonary tuberculosis [incident rate 15.98 (15.47–16.51)/100 person-years at risk (PYAR), oral candidiasis [incident rate 12.5 (12.03–12.94)] and herpes zoster [incident rate 6.30 (5.99–6.64)] events/100 PYAR. With attainment of a CD4+ cell count level 200–350 cells/μl, there was a substantial reduction in events/100 PYAR – by 91% to 1.45 (1.29–1.63) for TB, by 94% to 0.75 (0.64–0.89) for oral candidiasis, by 84% to 0.99 (0.86–1.14) for Herpes Zoster, and by 78% to 1.22 (1.07–1.39) for chronic diarrhea. The incidence of all events decreased further with CD4 counts above these thresholds. Conclusion Around 40% of adults initiated on ART have suboptimal immune recovery with CD4 counts <350 cells/ml after five years. Such patients will require closer monitoring for both HIV-related and non-HIV-related clinical events. PMID:26959510
Optimizing the duration of point counts for monitoring trends in bird populations
Jared Verner
1988-01-01
Minute-by-minute analysis of point counts of birds in mixed-conifer forests in the Sierra National Forest, central California, showed that cumulative counts of species and individuals increased in a curvilinear fashion but did not reach asymptotes after 10 minutes of counting. Comparison of the expected number of individuals counted per hour with various combinations...
Mann J.R.; Wainwright, A.E.
1963-06-11
An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER.
The survival of four Salmonella strains in river water microcosms was monitored using culturing techniques, direct counts, whole cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytrometry. Plate counts of...
Regression analysis of mixed recurrent-event and panel-count data
Zhu, Liang; Tong, Xinwei; Sun, Jianguo; Chen, Manhua; Srivastava, Deo Kumar; Leisenring, Wendy; Robison, Leslie L.
2014-01-01
In event history studies concerning recurrent events, two types of data have been extensively discussed. One is recurrent-event data (Cook and Lawless, 2007. The Analysis of Recurrent Event Data. New York: Springer), and the other is panel-count data (Zhao and others, 2010. Nonparametric inference based on panel-count data. Test 20, 1–42). In the former case, all study subjects are monitored continuously; thus, complete information is available for the underlying recurrent-event processes of interest. In the latter case, study subjects are monitored periodically; thus, only incomplete information is available for the processes of interest. In reality, however, a third type of data could occur in which some study subjects are monitored continuously, but others are monitored periodically. When this occurs, we have mixed recurrent-event and panel-count data. This paper discusses regression analysis of such mixed data and presents two estimation procedures for the problem. One is a maximum likelihood estimation procedure, and the other is an estimating equation procedure. The asymptotic properties of both resulting estimators of regression parameters are established. Also, the methods are applied to a set of mixed recurrent-event and panel-count data that arose from a Childhood Cancer Survivor Study and motivated this investigation. PMID:24648408
Long-term monitoring of endangered Laysan ducks: Index validation and population estimates 1998–2012
Reynolds, Michelle H.; Courtot, Karen; Brinck, Kevin W.; Rehkemper, Cynthia; Hatfield, Jeffrey
2015-01-01
Monitoring endangered wildlife is essential to assessing management or recovery objectives and learning about population status. We tested assumptions of a population index for endangered Laysan duck (or teal; Anas laysanensis) monitored using mark–resight methods on Laysan Island, Hawai’i. We marked 723 Laysan ducks between 1998 and 2009 and identified seasonal surveys through 2012 that met accuracy and precision criteria for estimating population abundance. Our results provide a 15-y time series of seasonal population estimates at Laysan Island. We found differences in detection among seasons and how observed counts related to population estimates. The highest counts and the strongest relationship between count and population estimates occurred in autumn (September–November). The best autumn surveys yielded population abundance estimates that ranged from 674 (95% CI = 619–730) in 2003 to 339 (95% CI = 265–413) in 2012. A population decline of 42% was observed between 2010 and 2012 after consecutive storms and Japan’s To¯hoku earthquake-generated tsunami in 2011. Our results show positive correlations between the seasonal maximum counts and population estimates from the same date, and support the use of standardized bimonthly counts of unmarked birds as a valid index to monitor trends among years within a season at Laysan Island.
A high dynamic range pulse counting detection system for mass spectrometry.
Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng
2014-01-30
A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
1992-01-01
Mestech's X-15 "Eye in the Sky," a traffic monitoring system, incorporates NASA imaging and robotic vision technology. A camera or "sensor box" is mounted in a housing. The sensor detects vehicles approaching an intersection and sends the information to a computer, which controls the traffic light according to the traffic rate. Jet Propulsion Laboratory technical support packages aided in the company's development of the system. The X-15's "smart highway" can also be used to count vehicles on a highway and compute the number in each lane and their speeds, important information for freeway control engineers. Additional applications are in airport and railroad operations. The system is intended to replace loop-type traffic detectors.
Development of a nuclear technique for monitoring water levels in pressurized vehicles
NASA Technical Reports Server (NTRS)
Singh, J. J.; Davis, W. T.; Mall, G. H.
1983-01-01
A new technique for monitoring water levels in pressurized stainless steel cylinders was developed. It is based on differences in attenuation coefficients of water and air for Cs137 (662 keV) gamma rays. Experimentally observed gamma ray counting rates with and without water in model reservoir cylinder were compared with corresponding calculated values for two different gamma ray detection theshold energies. Calculated values include the effects of multiple scattering and attendant gamma ray energy reductions. The agreement between the measured and calculated values is reasonably good. Computer programs for calculating angular and spectral distributions of scattered radition in various media are included.
Crewe, Tara L; Taylor, Philip D; Lepage, Denis
2015-01-01
The use of counts of unmarked migrating animals to monitor long term population trends assumes independence of daily counts and a constant rate of detection. However, migratory stopovers often last days or weeks, violating the assumption of count independence. Further, a systematic change in stopover duration will result in a change in the probability of detecting individuals once, but also in the probability of detecting individuals on more than one sampling occasion. We tested how variation in stopover duration influenced accuracy and precision of population trends by simulating migration count data with known constant rate of population change and by allowing daily probability of survival (an index of stopover duration) to remain constant, or to vary randomly, cyclically, or increase linearly over time by various levels. Using simulated datasets with a systematic increase in stopover duration, we also tested whether any resulting bias in population trend could be reduced by modeling the underlying source of variation in detection, or by subsampling data to every three or five days to reduce the incidence of recounting. Mean bias in population trend did not differ significantly from zero when stopover duration remained constant or varied randomly over time, but bias and the detection of false trends increased significantly with a systematic increase in stopover duration. Importantly, an increase in stopover duration over time resulted in a compounding effect on counts due to the increased probability of detection and of recounting on subsequent sampling occasions. Under this scenario, bias in population trend could not be modeled using a covariate for stopover duration alone. Rather, to improve inference drawn about long term population change using counts of unmarked migrants, analyses must include a covariate for stopover duration, as well as incorporate sampling modifications (e.g., subsampling) to reduce the probability that individuals will be detected on more than one occasion.
Shifts in intended and unintended pregnancies in the United States, 2001-2008.
Finer, Lawrence B; Zolna, Mia R
2014-02-01
We monitored trends in pregnancy by intendedness and outcomes of unintended pregnancies nationally and for key subgroups between 2001 and 2008. Data on pregnancy intentions from the National Survey of Family Growth (NSFG) and a nationally representative survey of abortion patients were combined with counts of births (from the National Center for Health Statistics), counts of abortions (from a census of abortion providers), estimates of miscarriages (from the NSFG), and population denominators from the US Census Bureau to obtain pregnancy rates by intendedness. In 2008, 51% of pregnancies in the United States were unintended, and the unintended pregnancy rate was 54 per 1000 women ages 15 to 44 years. Between 2001 and 2008, intended pregnancies decreased and unintended pregnancies increased, a shift previously unobserved. Large disparities in unintended pregnancy by relationship status, income, and education increased; the percentage of unintended pregnancies ending in abortion decreased; and the rate of unintended pregnancies ending in birth increased, reaching 27 per 1000 women. Reducing unintended pregnancy likely requires addressing fundamental socioeconomic inequities, as well as increasing contraceptive use and the uptake of highly effective methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hausladen, Paul; Blessinger, Christopher S; Guzzardo, Tyler
A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associatedmore » with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.« less
Deposition and persistence of beachcast seabird carcasses
van Pelt, Thomas I.; Piatt, John F.
1995-01-01
Following a massive wreck of guillemots (Uria aalge) in late winter and spring of 1993, we monitored the deposition and subsequent disappearance of 398 beachcast guillemot carcasses on two beaches in Resurrection Bay, Alaska, during a 100 day period. Deposition of carcasses declined logarithmically with time after the original event. Since fresh carcasses were more likely to be removed between counts than older carcasses, persistence rates increased logarithmically over time. Scavenging appeared to be the primary cause of carcass removal, followed by burial in beach debris and sand. Along-shore transport was negligible. We present an equation which estimates the number of carcasses deposited at time zero from beach surveys conducted some time later, using non-linear persistence rates that are a function of time. We use deposition rates to model the accumulation of beached carcasses, accounting for further deposition subsequent to the original event. Finally, we present a general method for extrapolating from a single count the number of carcasses cumulatively deposited on surveyed beaches, and discuss how our results can be used to assess the magnitude of mass seabird mortality events from beach surveys.
Sources and magnitude of sampling error in redd counts for bull trout
Jason B. Dunham; Bruce Rieman
2001-01-01
Monitoring of salmonid populations often involves annual redd counts, but the validity of this method has seldom been evaluated. We conducted redd counts of bull trout Salvelinus confluentus in two streams in northern Idaho to address four issues: (1) relationships between adult escapements and redd counts; (2) interobserver variability in redd...
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER
The survival of four Salmonella strains in river water microcosms was monitored by culturing techniques, direct counts, whole-cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytometry. Plate counts of bact...
Compton suppression gamma-counting: The effect of count rate
Millard, H.T.
1984-01-01
Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.
Pulse pileup statistics for energy discriminating photon counting x-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir
Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less
Martyniak, Brian; Bolton, Jason; Kuksin, Dmitry; Shahin, Suzanne M; Chan, Leo Li-Ying
2017-01-01
Brettanomyces spp. can present unique cell morphologies comprised of excessive pseudohyphae and budding, leading to difficulties in enumerating cells. The current cell counting methods include manual counting of methylene blue-stained yeasts or measuring optical densities using a spectrophotometer. However, manual counting can be time-consuming and has high operator-dependent variations due to subjectivity. Optical density measurement can also introduce uncertainties where instead of individual cells counted, an average of a cell population is measured. In contrast, by utilizing the fluorescence capability of an image cytometer to detect acridine orange and propidium iodide viability dyes, individual cell nuclei can be counted directly in the pseudohyphae chains, which can improve the accuracy and efficiency of cell counting, as well as eliminating the subjectivity from manual counting. In this work, two experiments were performed to demonstrate the capability of Cellometer image cytometer to monitor Brettanomyces concentrations, viabilities, and budding/pseudohyphae percentages. First, a yeast propagation experiment was conducted to optimize software counting parameters for monitoring the growth of Brettanomyces clausenii, Brettanomyces bruxellensis, and Brettanomyces lambicus, which showed increasing cell concentrations, and varying pseudohyphae percentages. The pseudohyphae formed during propagation were counted either as multiple nuclei or a single multi-nuclei organism, where the results of counting the yeast as a single multi-nuclei organism were directly compared to manual counting. Second, a yeast fermentation experiment was conducted to demonstrate that the proposed image cytometric analysis method can monitor the growth pattern of B. lambicus and B. clausenii during beer fermentation. The results from both experiments displayed different growth patterns, viability, and budding/pseudohyphae percentages for each Brettanomyces species. The proposed Cellometer image cytometry method can improve efficiency and eliminate operator-dependent variations of cell counting compared with the traditional methods, which can potentially improve the quality of beverage products employing Brettanomyces yeasts.
García-Prieto, Jorge Cañete; Martinez-Vizcaino, Vicente; García-Hermoso, Antonio; Sánchez-López, Mairena; Arias-Palencia, Natalia; Fonseca, Juan Fernando Ortega; Mora-Rodriguez, Ricardo
2017-10-01
The aim of this study was to examine the energy expenditure (EE) measured using indirect calorimetry (IC) during playground games and to assess the validity of heart rate (HR) and accelerometry counts as indirect indicators of EE in children´s physical activity games. 32 primary school children (9.9 ± 0.6 years old, 19.8 ± 4.9 kg · m -2 BMI and 37.6 ± 7.2 ml · kg -1 · min -1 VO 2max ). Indirect calorimetry (IC), accelerometry and HR data were simultaneously collected for each child during a 90 min session of 30 playground games. Thirty-eight sessions were recorded in 32 different children. Each game was recorded at least in three occasions in other three children. The intersubject coefficient of variation within a game was 27% for IC, 37% for accelerometry and 13% for HR. The overall mean EE in the games was 4.2 ± 1.4 kcals · min -1 per game, totaling to 375 ± 122 kcals/per 90 min/session. The correlation coefficient between indirect calorimetry and accelerometer counts was 0.48 (p = .026) for endurance games and 0.21 (p = .574) for strength games. The correlation coefficient between indirect calorimetry and HR was 0.71 (p = .032) for endurance games and 0.48 (p = .026) for strength games. Our data indicate that both accelerometer and HR monitors are useful devices for estimating EE during endurance games, but only HR monitors estimates are accurate for endurance games.
A land manager's guide to point counts of birds in the Southeast
Hamel, P.B.; Smith, W.P.; Twedt, D.J.; Woehr, J.R.; Morris, E.; Hamilton, R.B.; Cooper, R.J.
1996-01-01
Current widespread concern for the status of neotropical migratory birds has sparked interest in techniques for inventorying and monitoring populations of these and other birds in southeastern forest habitats. The present guide gives detailed instructions for conducting point counts of birds. It further presents a detailed methodology for the design and conduct of inventorial and monitoring surveys based on point counts, including discussion of sample size determination, distribution of counts among habitats, cooperation among neighboring land managers, vegetation sampling, standard data format, and other topics. Appendices provide additional information, making this guide a stand-alone text for managers interested in developing inventories of bird populations on their lands.
All-Sky Earth Occultation Observations with the Fermi Gamma-Ray Burst Monitor
NASA Technical Reports Server (NTRS)
Wilson-Hodge, C. A.; Beklen, E.; Bhat, P. N.; Briggs, M.; Camero-Arranz, A.; Case, G.; Jenke, P.; Chaplin, V.; Cherry, M.; Connaughton, V.;
2009-01-01
Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/ soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. In addition, to Earth occultations, we have observed numerous occultations with Fermi's solar panels.
[Hematological changes in adolescent anorexia nervosa].
Bühren, Katharina; Gärtner, Laura; Kennes, Lieven N; Seitz, Jochen; Hagenah, Ulrich; Herpertz-Dahlmann, Beate
2014-01-01
Hematological changes often occur in patients with acute anorexia nervosa (AN). However, the relationship between these disturbances and other clinical parameters remains unclear. Leucocyte, erythrocyte, and thrombocyte counts as well as hematocrit, hemoglobin, and differential blood counts were collected at admission and after weight restoration in 88 female adolescent patients with the diagnosis of AN according to DSM-IV. These were then compared to clinical parameters. At admission, there were mild changes in the blood count, most of which, however, were reversible after weight gain. Patients with a greater weight loss, a lower age-adjusted BMI, and a history of taking psychotropic drugs were more likely to develop hematological abnormalities. Although most of the hematological changes in adolescent patients with AN were mild, patients with high weight loss and/or low age-adjusted BMI as well as those on psychotropic medication should be monitored carefully in order to avoid severe medical complications. An altered immune function in adult patients with chronic AN might contribute to a higher rate of infections and thus to an increased mortality.
Sustainable Seas Student Intertidal Monitoring Project at Duxbury Reef in Bolinas, CA
NASA Astrophysics Data System (ADS)
Soave, K.; Dean, A.; Weigel, S.; Redman, K.; Darakananda, D.; Fuller, C.; Gusman, V.; Hirschfeld, Z.; Kornfeld, H.; Picchi, K.
2006-12-01
The Sustainable Seas Student Monitoring Project at the Branson School in Ross, CA has monitored Duxbury Reef in Bolinas, CA since 1999, in cooperation with the Farallones Marine Sanctuary Association and the Gulf of Farallones National Marine Sanctuary. Goals of the project include: 1) To monitor the rocky intertidal habitat and develop a baseline database of invertebrates and algal density and abundance; 2) To contribute to the conservation of the rocky intertidal habitat through education of students and visitors about intertidal species and requirements for maintaining a healthy, diverse intertidal ecosystem; 3) To increase stewardship in the Gulf of the Farallones National Marine Sanctuary; and 4) To contribute abundance and population data on key algae and invertebrate species to the national database, LiMPETS (Long Term Monitoring Program & Experiential Training for Students). Student volunteers complete an intensive training course on the natural history of intertidal invertebrates and algae, identification of key species, rocky intertidal ecology, interpretation and monitoring techniques, and history of the sanctuary. Students conduct two baseline-monitoring surveys three times per year (fall, winter, and late spring) to identify and count key invertebrate and algae species. During six seasons of monitoring (2000-2006), the density of black turban snails, Tegula funebralis, showed seasonal abundance variation with respect to tidal zonation. Most algae species had consistently lower densities in the more accessible northern (A) transects than the southern (B) transects. To test the reliability of the student counts, replicate counts of all species are always performed. Replicate counts for invertebrate and algae species within the same quadrat along the permanent transects revealed a very small amount of variability, giving us confidence that our monitoring program is providing reliable data.
Maskasame, Sarin; Krisanaprakornkit, Thawatchai; Khiewyoo, Jiraporn
2007-10-01
Define the incidence of clozapine-induced leukopenia, neutropenia, and agranulocytosis in patients with schizophrenia at Srinagarind Hospital. A descriptive study was done by retrospective reviews of the medical records of schizophrenic outpatients at psychiatric clinic in Srinagarind Hospital who had received clozapine from January 1st, 2003 to December 31st, 2005. The demographic data, incidence rate, and incidence density of leukopenia, neutropenia, and agranulocytosis were collected. One hundred and seventeen medical records were reviewed, 65 patients met the inclusion criteria. One patient developed neutropenia. The incidence rate of neutropenia was 1.5% and the incidence density of neutropenia was 0.01/year. No leukopenia or agranulocytosis was found in the present study. The complete blood counts were not obtained regularly due to the problems of patient's adherence and variations in practice among the physicians. Neutropenia is uncommon. No leukopenia and agranulocytosis were found. According to variations of incidence reports among different studies, the monitoring of white blood count should be continued.
Walker, R.S.; Novare, A.J.; Nichols, J.D.
2000-01-01
Estimation of abundance of mammal populations is essential for monitoring programs and for many ecological investigations. The first step for any study of variation in mammal abundance over space or time is to define the objectives of the study and how and why abundance data are to be used. The data used to estimate abundance are count statistics in the form of counts of animals or their signs. There are two major sources of uncertainty that must be considered in the design of the study: spatial variation and the relationship between abundance and the count statistic. Spatial variation in the distribution of animals or signs may be taken into account with appropriate spatial sampling. Count statistics may be viewed as random variables, with the expected value of the count statistic equal to the true abundance of the population multiplied by a coefficient p. With direct counts, p represents the probability of detection or capture of individuals, and with indirect counts it represents the rate of production of the signs as well as their probability of detection. Comparisons of abundance using count statistics from different times or places assume that the p are the same for all times or places being compared (p= pi). In spite of considerable evidence that this assumption rarely holds true, it is commonly made in studies of mammal abundance, as when the minimum number alive or indices based on sign counts are used to compare abundance in different habitats or times. Alternatives to relying on this assumption are to calibrate the index used by testing the assumption of p= pi, or to incorporate the estimation of p into the study design.
Regression analysis of mixed recurrent-event and panel-count data with additive rate models.
Zhu, Liang; Zhao, Hui; Sun, Jianguo; Leisenring, Wendy; Robison, Leslie L
2015-03-01
Event-history studies of recurrent events are often conducted in fields such as demography, epidemiology, medicine, and social sciences (Cook and Lawless, 2007, The Statistical Analysis of Recurrent Events. New York: Springer-Verlag; Zhao et al., 2011, Test 20, 1-42). For such analysis, two types of data have been extensively investigated: recurrent-event data and panel-count data. However, in practice, one may face a third type of data, mixed recurrent-event and panel-count data or mixed event-history data. Such data occur if some study subjects are monitored or observed continuously and thus provide recurrent-event data, while the others are observed only at discrete times and hence give only panel-count data. A more general situation is that each subject is observed continuously over certain time periods but only at discrete times over other time periods. There exists little literature on the analysis of such mixed data except that published by Zhu et al. (2013, Statistics in Medicine 32, 1954-1963). In this article, we consider the regression analysis of mixed data using the additive rate model and develop some estimating equation-based approaches to estimate the regression parameters of interest. Both finite sample and asymptotic properties of the resulting estimators are established, and the numerical studies suggest that the proposed methodology works well for practical situations. The approach is applied to a Childhood Cancer Survivor Study that motivated this study. © 2014, The International Biometric Society.
Accuracy of acoustic respiration rate monitoring in pediatric patients.
Patino, Mario; Redford, Daniel T; Quigley, Thomas W; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter
2013-12-01
Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. Thirty-nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min(-1) from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were -0.30 ± 3.5 b·min(-1) and -7.3 to 6.6 b·min(-1) for RRa compared with capnography; -0.1 ± 2.5 b·min(-1) and -5.0 to 5.0 b·min(-1) for RRa compared with the reference method; and 0.2 ± 3.4 b·min(-1) and -6.8 to 6.7 b·min(-1) for capnography compared with the reference method. When compared to nasal capnography, RRa showed good agreement and similar accuracy and precision but was better tolerated in postsurgical pediatric patients. © 2013 John Wiley & Sons Ltd.
Regression analysis of mixed recurrent-event and panel-count data.
Zhu, Liang; Tong, Xinwei; Sun, Jianguo; Chen, Manhua; Srivastava, Deo Kumar; Leisenring, Wendy; Robison, Leslie L
2014-07-01
In event history studies concerning recurrent events, two types of data have been extensively discussed. One is recurrent-event data (Cook and Lawless, 2007. The Analysis of Recurrent Event Data. New York: Springer), and the other is panel-count data (Zhao and others, 2010. Nonparametric inference based on panel-count data. Test 20: , 1-42). In the former case, all study subjects are monitored continuously; thus, complete information is available for the underlying recurrent-event processes of interest. In the latter case, study subjects are monitored periodically; thus, only incomplete information is available for the processes of interest. In reality, however, a third type of data could occur in which some study subjects are monitored continuously, but others are monitored periodically. When this occurs, we have mixed recurrent-event and panel-count data. This paper discusses regression analysis of such mixed data and presents two estimation procedures for the problem. One is a maximum likelihood estimation procedure, and the other is an estimating equation procedure. The asymptotic properties of both resulting estimators of regression parameters are established. Also, the methods are applied to a set of mixed recurrent-event and panel-count data that arose from a Childhood Cancer Survivor Study and motivated this investigation. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
O’Connell, Sandra; ÓLaighin, Gearóid; Kelly, Lisa; Murphy, Elaine; Beirne, Sorcha; Burke, Niall; Kilgannon, Orlaith; Quinlan, Leo R.
2016-01-01
Introduction Physical activity is a vitally important part of a healthy lifestyle, and is of major benefit to both physical and mental health. A daily step count of 10,000 steps is recommended globally to achieve an appropriate level of physical activity. Accurate quantification of physical activity during conditions reflecting those needed to achieve the recommended daily step count of 10,000 steps is essential. As such, we aimed to assess four commercial activity monitors for their sensitivity/accuracy in a prescribed walking route that reflects a range of surfaces that would typically be used to achieve the recommended daily step count, in two types of footwear expected to be used throughout the day when aiming to achieve the recommended daily step count, and in a timeframe required to do so. Methods Four commercial activity monitors were worn simultaneously by participants (n = 15) during a prescribed walking route reflective of surfaces typically encountered while achieving the daily recommended 10,000 steps. Activity monitors tested were the Garmin Vivofit ™, New Lifestyles’ NL-2000 ™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2) ™, and Fitbit One ™. Results All activity monitors tested were accurate in their step detection over the variety of different surfaces tested (natural lawn grass, gravel, ceramic tile, tarmacadam/asphalt, linoleum), when wearing both running shoes and hard-soled dress shoes. Conclusion All activity monitors tested were accurate in their step detection sensitivity and are valid monitors for physical activity quantification over the variety of different surfaces tested, when wearing both running shoes and hard-soled dress shoes, and over a timeframe necessary for accumulating the recommended daily step count of 10,000 steps. However, it is important to consider the accuracy of activity monitors, particularly when physical activity in the form of stepping activities is prescribed as an intervention in the treatment or prevention of a disease state. PMID:27167121
Capacity for self-monitoring reading comprehension in Elementary School.
Bueno, Gabriela Juliane; Carvalho, Carolina Alves Ferreira; Ávila, Clara Regina Brandão de
2017-06-08
To investigate the capacity for self-monitoring reading comprehension in Brazilian Elementary School students. Fifty-three Elementary students in the 5th and 9th grades from two Public Schools in the city of São Paulo were assessed. They were selected based on their oral reading rate and grouped according to their performance in reading comprehension in the following categories: Group with best comprehension: students with adequate rate and accuracy, without difficulties in reading comprehension; Group with worst comprehension: students with adequate rate and accuracy but with difficulties in reading comprehension. Two narrative texts followed by eight questions to assess reading comprehension were presented. Two sentences and two words were replaced by ungrammatical elements and pseudo-words. Under the condition of spontaneous monitoring, students read the text aloud and answered the questions. The analysis considered the calculation of hesitation, self-correction, repetitions and mistakes. Under the condition of directed monitoring, students were instructed to read the text, either aloud or silently, after being told that certain parts of the text could not make sense, and they were oriented to underline such parts. The analysis was carried out by counting of underlined items. The comparisons were made with the Mann-Whitney test. A difference was observed between the groups only at the sentence level among the 9th grade schoolchildren under the spontaneous monitoring and among the 5th grade schoolchildren under directed monitoring. Students with worst comprehension had a poorer performance to monitor the presence of ungrammatical sentences than their peers with best comprehension.
Safe and effective error rate monitors for SS7 signaling links
NASA Astrophysics Data System (ADS)
Schmidt, Douglas C.
1994-04-01
This paper describes SS7 error monitor characteristics, discusses the existing SUERM (Signal Unit Error Rate Monitor), and develops the recently proposed EIM (Error Interval Monitor) for higher speed SS7 links. A SS7 error monitor is considered safe if it ensures acceptable link quality and is considered effective if it is tolerant to short-term phenomena. Formal criteria for safe and effective error monitors are formulated in this paper. This paper develops models of changeover transients, the unstable component of queue length resulting from errors. These models are in the form of recursive digital filters. Time is divided into sequential intervals. The filter's input is the number of errors which have occurred in each interval. The output is the corresponding change in transmit queue length. Engineered EIM's are constructed by comparing an estimated changeover transient with a threshold T using a transient model modified to enforce SS7 standards. When this estimate exceeds T, a changeover will be initiated and the link will be removed from service. EIM's can be differentiated from SUERM by the fact that EIM's monitor errors over an interval while SUERM's count errored messages. EIM's offer several advantages over SUERM's, including the fact that they are safe and effective, impose uniform standards in link quality, are easily implemented, and make minimal use of real-time resources.
NASA Astrophysics Data System (ADS)
Armano, M.; Audley, H.; Baird, J.; Bassan, M.; Benella, S.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Cavalleri, A.; Cesarini, A.; Cruise, A. M.; Danzmann, K.; de Deus Silva, M.; Diepholz, I.; Dixon, G.; Dolesi, R.; Fabi, M.; Ferraioli, L.; Ferroni, V.; Finetti, N.; Fitzsimons, E. D.; Freschi, M.; Gesa, L.; Gibert, F.; Giardini, D.; Giusteri, R.; Grimani, C.; Grzymisch, J.; Harrison, I.; Heinzel, G.; Hewitson, M.; Hollington, D.; Hoyland, D.; Hueller, M.; Inchauspé, H.; Jennrich, O.; Jetzer, P.; Karnesis, N.; Kaune, B.; Korsakova, N.; Killow, C. J.; Laurenza, M.; Lobo, J. A.; Lloro, I.; Liu, L.; López-Zaragoza, J. P.; Maarschalkerweerd, R.; Mance, D.; Martín, V.; Martin-Polo, L.; Martino, J.; Martin-Porqueras, F.; Mateos, I.; McNamara, P. W.; Mendes, J.; Mendes, L.; Nofrarias, M.; Paczkowski, S.; Perreur-Lloyd, M.; Petiteau, A.; Pivato, P.; Plagnol, E.; Ramos-Castro, J.; Reiche, J.; Robertson, D. I.; Rivas, F.; Russano, G.; Sabbatini, F.; Slutsky, J.; Sopuerta, C. F.; Sumner, T.; Telloni, D.; Texier, D.; Thorpe, J. I.; Vetrugno, D.; Vitale, S.; Wanner, G.; Ward, H.; Wass, P.; Weber, W. J.; Wissel, L.; Wittchen, A.; Zambotti, A.; Zenoni, C.; Zweifel, P.
2018-02-01
Galactic cosmic-ray (GCR) energy spectra observed in the inner heliosphere are modulated by the solar activity, the solar polarity and structures of solar and interplanetary origin. A high counting rate particle detector (PD) aboard LISA Pathfinder, meant for subsystems diagnostics, was devoted to the measurement of GCR and solar energetic particle integral fluxes above 70 MeV n‑1 up to 6500 counts s‑1. PD data were gathered with a sampling time of 15 s. Characteristics and energy dependence of GCR flux recurrent depressions and of a Forbush decrease dated 2016 August 2 are reported here. The capability of interplanetary missions, carrying PDs for instrument performance purposes, in monitoring the passage of interplanetary coronal mass ejections is also discussed.
A robust hypothesis test for the sensitive detection of constant speed radiation moving sources
NASA Astrophysics Data System (ADS)
Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Moline, Yoann; Sannié, Guillaume; Gameiro, Jordan; Normand, Stéphane; Méchin, Laurence
2015-09-01
Radiation Portal Monitors are deployed in linear networks to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal-to-noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive backgrounds, and a vehicle source carrier under the same respectively high and low count rate radioactive backgrounds, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm. It also guarantees that the optimal coverage factor for this compromise remains stable regardless of signal-to-noise ratio variations between 2 and 0.8, therefore allowing the final user to parametrize the test with the sole prior knowledge of background amplitude.
A technology review of time-of-flight photon counting for advanced remote sensing
NASA Astrophysics Data System (ADS)
Lamb, Robert A.
2010-04-01
Time correlated single photon counting (TCSPC) has made tremendous progress during the past ten years enabling improved performance in precision time-of-flight (TOF) rangefinding and lidar. In this review the development and performance of several ranging systems is presented that use TCSPC for accurate ranging and range profiling over distances up to 17km. A range resolution of a few millimetres is routinely achieved over distances of several kilometres. These systems include single wavelength devices operating in the visible; multi-wavelength systems covering the visible and near infra-red; the use of electronic gating to reduce in-band solar background and, most recently, operation at high repetition rates without range aliasing- typically 10MHz over several kilometres. These systems operate at very low optical power (<100μW). The technique therefore has potential for eye-safe lidar monitoring of the environment and obvious military, security and surveillance sensing applications. The review will highlight the theoretical principles of photon counting and progress made in developing absolute ranging techniques that enable high repetition rate data acquisition that avoids range aliasing. Technology trends in TCSPC rangefinding are merging with those of quantum cryptography and its future application to revolutionary quantum imaging provides diverse and exciting research into secure covert sensing, ultra-low power active imaging and quantum rangefinding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenwood, L. R.; Cantaloub, M. G.; Burnett, J. L.
PNNL has developed two low-background gamma-ray spectrometers in a new shallow underground laboratory, thereby significantly improving its ability to detect low levels of gamma-ray emitting fission or activation products in airborne particulate in samples from the IMS (International Monitoring System). Furthermore, the combination of cosmic veto panels, dry nitrogen gas to reduce radon and low background shielding results in a reduction of the background count rate by about a factor of 100 compared to detectors operating above ground at our laboratory.
Colony attendance and population monitoring of Black-legged Kittiwakes on the Semidi Islands, Alaska
Hatch, Scott A.; Hatch, Martha A.
1988-01-01
Patterns of colony attendance in Black-legged Kittiwakes (Rissa tridactyla) were studied over 5 years on the Semidi Islands, western Gulf of Alaska. A census period of 50 days, extending from first egg laying through final hatching, was appropriate because counts made then were subject to the least amount of daily variation. Five counts during that period were sufficient to detect a 25% change in numbers between years; counts made on all 50 days of the census period would detect a 5 to 7% change. There was little evidence for seasonal trends or serial correlation of counts during the census period, but attendance was negatively correlated with wind speed. Half of an apparent 17% increase in population between 1980 and 1981 was due to birds spending more time at their nest sites in the latter year, thereby increasing the mean of attendance counts. Despite such difficulties in the interpretation of attendance counts, birds were considered to be better counting units for population monitoring than nests, because nest densities were subject to large annual fluctuations in breeding effort.
NASA Astrophysics Data System (ADS)
Krimmer, J.; Angellier, G.; Balleyguier, L.; Dauvergne, D.; Freud, N.; Hérault, J.; Létang, J. M.; Mathez, H.; Pinto, M.; Testa, E.; Zoccarato, Y.
2017-04-01
For the purpose of detecting deviations from the prescribed treatment during particle therapy, the integrals of uncollimated prompt gamma-ray timing distributions are investigated. The intention is to provide information, with a simple and cost-effective setup, independent from monitoring devices of the beamline. Measurements have been performed with 65 MeV protons at a clinical cyclotron. Prompt gamma-rays emitted from the target are identified by means of time-of-flight. The proton range inside the PMMA target has been varied via a modulator wheel. The measured variation of the prompt gamma peak integrals as a function of the modulator position is consistent with simulations. With detectors covering a solid angle of 25 msr (corresponding to a diameter of 3-4 in. at a distance of 50 cm from the beam axis) and 108 incident protons, deviations of a few per cent in the prompt gamma-ray count rate can be detected. For the present configuration, this change in the count rate corresponds to a 3 mm change in the proton range in a PMMA target. Furthermore, simulation studies show that a combination of the signals from multiple detectors may be used to detect a misplacement of the target. A different combination of these signals results in a precise number of the detected prompt gamma rays, which is independent on the actual target position.
Nathaniel E. Seavy; Suhel Quader; John D. Alexander; C. John Ralph
2005-01-01
The success of avian monitoring programs to effectively guide management decisions requires that studies be efficiently designed and data be properly analyzed. A complicating factor is that point count surveys often generate data with non-normal distributional properties. In this paper we review methods of dealing with deviations from normal assumptions, and we focus...
Thanhaeuser, Margarita; Binder, Christoph; Derhaschnig, Ulla; Jilma, Bernd; Kornsteiner-Krenn, Margit; Huber-Dangl, Mercedes; Repa, Andreas; Kreissl, Alexandra; Berger, Angelika; Haiden, Nadja
2018-06-04
Bleeds such as intra-ventricular (IVH) and pulmonary haemorrhage (PH) are life-threatening events in extremely low birth weight (ELBW) infants. Serial coagulation monitoring by measuring the international normalized ratio (INR) with small volume samples might facilitate early diagnosis and possibly prevent major bleeds. This was a prospective longitudinal study performed in ELBW infants, who received serial INR monitoring by point of care testing during their first 30 days of life. The primary objective was to explore whether INR monitoring could predict major bleeding events (IVH, PH). Secondary objectives were mortality and feasibility in this patient population. A total of 127 ELBW infants were stratified into a bleeding and a non-bleeding group. Bleeding events occurred in 31% (39/127) of the infants, whereupon 24% developed IVH and 9% PH. Infants in the bleeding group were 4 days younger at birth ( p = 0.05) and had a substantially higher mortality rate of 26% versus 5% in controls ( p = 0.005). Median INR during the first 3 days before a bleeding event was 1.55 (95% confidence interval [CI]: 1.39-1.74) compared with the control group with 1.45 (95% CI: 1.44-1.58; p = 0.81). Platelet counts were significantly lower in the bleeding group on the 3rd day and during the 2nd to 4th week of life. Serial coagulation monitoring by an INR point of care testing is feasible in ELBW infants but could not predict bleeding events. Further studies with daily monitoring of INR and platelet counts during the first days of life might be able to more precisely detect a risk of major haemorrhage in ELBW infants. Schattauer GmbH Stuttgart.
Spatially-Aware Temporal Anomaly Mapping of Gamma Spectra
NASA Astrophysics Data System (ADS)
Reinhart, Alex; Athey, Alex; Biegalski, Steven
2014-06-01
For security, environmental, and regulatory purposes it is useful to continuously monitor wide areas for unexpected changes in radioactivity. We report on a temporal anomaly detection algorithm which uses mobile detectors to build a spatial map of background spectra, allowing sensitive detection of any anomalies through many days or months of monitoring. We adapt previously-developed anomaly detection methods, which compare spectral shape rather than count rate, to function with limited background data, allowing sensitive detection of small changes in spectral shape from day to day. To demonstrate this technique we collected daily observations over the period of six weeks on a 0.33 square mile research campus and performed source injection simulations.
Selective data segment monitoring system. [using shift registers
NASA Technical Reports Server (NTRS)
Wirth, M. N. (Inventor)
1976-01-01
High speed data monitoring apparatus is described for displaying the bit pattern of a selected portion of a block of transmitted data comprising a shift register for receiving the transmitted data and for temporarily containing the consecutive data bits. A programmable sync detector for monitoring the contents of the shift register and for generating a sync signal when the shift register contains a predetermined sync code is included. A counter is described for counting the data bits input to the shift register after the sync signal is generated and for generating a count complete signal when a selected number of data bits have been input to the register. A data storage device is used for storing the contents of the shift register at the time the count complete signal is generated.
Hopfield neural network and optical fiber sensor as intelligent heart rate monitor
NASA Astrophysics Data System (ADS)
Mutter, Kussay Nugamesh
2018-01-01
This paper presents a design and fabrication of an intelligent fiber-optic sensor used for examining and monitoring heart rate activity. It is found in the literature that the use of fiber sensors as heart rate sensor is widely studied. However, the use of smart sensors based on Hopfield neural networks is very low. In this work, the sensor is a three fibers without cladding of about 1 cm, fed by laser light of 1550 nm of wavelength. The sensing portions are mounted with a micro sensitive diaphragm to transfer the pulse pressure on the left radial wrist. The influenced light intensity will be detected by a three photodetectors as inputs into the Hopfield neural network algorithm. The latter is a singlelayer auto-associative memory structure with a same input and output layers. The prior training weights are stored in the net memory for the standard recorded normal heart rate signals. The sensors' heads work on the reflection intensity basis. The novelty here is that the sensor uses a pulse pressure and Hopfield neural network in an integrity approach. The results showed a significant output measurements of heart rate and counting with a plausible error rate.
NASA Astrophysics Data System (ADS)
Hsieh, Scott S.; Pelc, Norbert J.
2014-06-01
Photon counting x-ray detectors (PCXDs) offer several advantages compared to standard energy-integrating x-ray detectors, but also face significant challenges. One key challenge is the high count rates required in CT. At high count rates, PCXDs exhibit count rate loss and show reduced detective quantum efficiency in signal-rich (or high flux) measurements. In order to reduce count rate requirements, a dynamic beam-shaping filter can be used to redistribute flux incident on the patient. We study the piecewise-linear attenuator in conjunction with PCXDs without energy discrimination capabilities. We examined three detector models: the classic nonparalyzable and paralyzable detector models, and a ‘hybrid’ detector model which is a weighted average of the two which approximates an existing, real detector (Taguchi et al 2011 Med. Phys. 38 1089-102 ). We derive analytic expressions for the variance of the CT measurements for these detectors. These expressions are used with raw data estimated from DICOM image files of an abdomen and a thorax to estimate variance in reconstructed images for both the dynamic attenuator and a static beam-shaping (‘bowtie’) filter. By redistributing flux, the dynamic attenuator reduces dose by 40% without increasing peak variance for the ideal detector. For non-ideal PCXDs, the impact of count rate loss is also reduced. The nonparalyzable detector shows little impact from count rate loss, but with the paralyzable model, count rate loss leads to noise streaks that can be controlled with the dynamic attenuator. With the hybrid model, the characteristic count rates required before noise streaks dominate the reconstruction are reduced by a factor of 2 to 3. We conclude that the piecewise-linear attenuator can reduce the count rate requirements of the PCXD in addition to improving dose efficiency. The magnitude of this reduction depends on the detector, with paralyzable detectors showing much greater benefit than nonparalyzable detectors.
On the Slow time Geomagnetic field Modulation of Cosmic Rays
NASA Astrophysics Data System (ADS)
Okpala, K. C.; Egbunu, F.
2016-12-01
Cosmic rays of galactic origin are modulated by both heliospheric and geomagnetic conditions. The mutual (and mutually exclusive) contribution of both heliospheric and geomagnetic conditions to galactic cosmic rays (GCR) modulation is still an open question. While the rapid-time association of the galactic cosmic ray variation with different heliophysical and geophysical phenomena has been well studied, not so much attention has been paid to slow-time variations especially with regards to local effects. In this work, we employed monthly means of cosmic ray count rates from two mid latitude (Hermanus and Rome), and two higher latitude (Inuvik and Oulu) neutron monitors (NM), and compared their variability with geomagnetic stations that are in close proximity to the NMs. The data spans 1966 to 2008 and covers four (4) solar cycles. The difference (CRdiff)between the mean count rate of all days and the mean of the five quietest days for each month was compared with the Dst-related disturbance (Hdiff) derived from the nearby geomagnetic stations. Zeroth- and First- correlation between the cosmic ray parameters and geomagnetic parameters was performed to ascertain statistical association and test for spurious association. Our results show that solar activity is generally strongly correlated (>0.75) with mean strength of GCR count rate and geomagnetic field during individual solar cycles. The correlation between mean strength of cosmic ray intensity and Geomagnetic field strength is spurious and is basically moderated by the solar activity. The signature of convection driven disturbances at high latitude geomagnetic stations was evident during the declining phase of the solar cycles close to the solar minimums. The absence of this feature in the slow-time varying cosmic ray count rates in all stations, and in the mid latitude geomagnetic stations suggest that the local geomagnetic disturbance do not play a significant role in modulating the cosmic ray flux.
NASA Astrophysics Data System (ADS)
Eriksson, L.; Wienhard, K.; Eriksson, M.; Casey, M. E.; Knoess, C.; Bruckbauer, T.; Hamill, J.; Mulnix, T.; Vollmar, S.; Bendriem, B.; Heiss, W. D.; Nutt, R.
2002-06-01
The first and second generation of the Exact and Exact HR family of scanners has been evaluated in terms of noise equivalent count rate (NEC) and count-rate capabilities. The new National Electrical Manufacturers Association standard was used for the evaluation. In spite of improved electronics and improved count-rate capabilities, the peak NEC was found to be fairly constant between the generations. The results are discussed in terms of the different electronic solutions for the two generations and its implications on system dead time and NEC count-rate capability.
Ford, Deborah; Robins, James M.; Petersen, Maya L.; Gibb, Diana M.; Gilks, Charles F.; Mugyenyi, Peter; Grosskurth, Heiner; Hakim, James; Katabira, Elly; Babiker, Abdel G.; Walker, A. Sarah
2015-01-01
In Africa, antiretroviral therapy (ART) is delivered with limited laboratory monitoring, often none. In 2003–2004, investigators in the Development of Antiretroviral Therapy in Africa (DART) Trial randomized persons initiating ART in Uganda and Zimbabwe to either laboratory and clinical monitoring (LCM) or clinically driven monitoring (CDM). CD4 cell counts were measured every 12 weeks in both groups but were only returned to treating clinicians for management in the LCM group. Follow-up continued through 2008. In observational analyses, dynamic marginal structural models on pooled randomized groups were used to estimate survival under different monitoring-frequency and clinical/immunological switching strategies. Assumptions included no direct effect of randomized group on mortality or confounders and no unmeasured confounders which influenced treatment switch and mortality or treatment switch and time-dependent covariates. After 48 weeks of first-line ART, 2,946 individuals contributed 11,351 person-years of follow-up, 625 switches, and 179 deaths. The estimated survival probability after a further 240 weeks for post-48-week switch at the first CD4 cell count less than 100 cells/mm3 or non-Candida World Health Organization stage 4 event (with CD4 count <250) was 0.96 (95% confidence interval (CI): 0.94, 0.97) with 12-weekly CD4 testing, 0.96 (95% CI: 0.95, 0.97) with 24-weekly CD4 testing, 0.95 (95% CI: 0.93, 0.96) with a single CD4 test at 48 weeks (baseline), and 0.92 (95% CI: 0.91, 0.94) with no CD4 testing. Comparing randomized groups by 48-week CD4 count, the mortality risk associated with CDM versus LCM was greater in persons with CD4 counts of <100 (hazard ratio = 2.4, 95% CI: 1.3, 4.3) than in those with CD4 counts of ≥100 (hazard ratio = 1.1, 95% CI: 0.8, 1.7; interaction P = 0.04). These findings support a benefit from identifying patients immunologically failing first-line ART at 48 weeks. PMID:26316598
Aminian, Saeideh; Hinckson, Erica A
2012-10-02
Decreasing sedentary activities that involve prolonged sitting may be an important strategy to reduce obesity and other physical and psychosocial health problems in children. The first step to understanding the effect of sedentary activities on children's health is to objectively assess these activities with a valid measurement tool. To examine the validity of the ActivPAL monitor in measuring sitting/lying, standing, and walking time, transition counts and step counts in children in a laboratory setting. Twenty five healthy elementary school children (age 9.9 ± 0.3 years; BMI 18.2 ± 1.9; mean ± SD) were randomly recruited across the Auckland region, New Zealand. Children were fitted with ActivPAL monitors and observed during simulated free-living activities involving sitting/lying, standing and walking, followed by treadmill and over-ground activities at various speeds (slow, normal, fast) against video observation (criterion measure). The ActivPAL sit-to-stand and stand-to-sit transition counts and steps were also compared with video data. The accuracy of step counts measured by the ActivPAL was also compared against the New Lifestyles NL-2000 and the Yamax Digi-Walker SW-200 pedometers. We observed a perfect correlation between the ActivPAL monitor in time spent sitting/lying, standing, and walking in simulated free-living activities with direct observation. Correlations between the ActivPAL and video observation in total numbers of sit-to-stand and stand-to-sit transitions were high (r = 0.99 ± 0.01). Unlike pedometers, the ActivPAL did not misclassify fidgeting as steps taken. Strong correlations (r = 0.88-1.00) between ActivPAL step counts and video observation in both treadmill and over-ground slow and normal walking were also observed. During treadmill and over-ground fast walking and running, the correlations were low (r = 0.21-0.46). The ActivPAL monitor is a valid measurement tool for assessing time spent sitting/lying, standing, and walking, sit-to-stand and stand-to-sit transition counts and step counts in slow and normal walking. The device did not measure accurately steps taken during treadmill and over-ground fast walking and running in children.
Compensated count-rate circuit for radiation survey meter
Todd, Richard A.
1981-01-01
A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.
TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Couture, A.
2011-09-20
This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector outputmore » will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.« less
Ogero, Morris; Ayieko, Philip; Makone, Boniface; Julius, Thomas; Malla, Lucas; Oliwa, Jacquie; Irimu, Grace; English, Mike
2018-06-01
Measurement and correct interpretation of vital signs is part of routine clinical care. Repeated measurement enhances early recognition of deterioration, may help prevent morbidity and mortality and is a standard of care in most countries. To examine documentation of vital signs by clinicians for admissions to paediatric wards in Kenyan hospitals, to describe monitoring frequency by nurses and explore factors influencing frequency. Vital signs information (temperature, respiratory and pulse rate) for the first 48 hours of admission was collected from case records of children admitted with non-surgical conditions to 13 Kenyan county hospitals between September 2013 and April 2016. A mixed effect negative binomial regression model was used to explore whether the severity of illness (indicated by danger signs or severe diagnostic episodes) is associated with increased vital signs observation frequency. We examined 54 800 admission episodes with an overall mortality 6.1%. Nurse to bed ratios were very low (1:10 to 1:41 across hospitals). Admitting clinicians documented all or no vital signs in 57.0% and 8.4% cases respectively. For respiratory and pulse rates there was pronounced even end-digit preference (an indicator of incorrect information) and high frequency recording of specific values ( P < 0.001) suggesting approximation. Monitoring frequency was explored in 41 738 children. Those with inpatient stays ≥48 hours were expected to have a vital signs count of 18, hospitals varied but most did not achieve this benchmark (median 9, range 2-30). There were clinically small but significant associations between vital signs count and presence of multiple severe illnesses or presence of severe pallor (adjusted relative risk ratio = 1.04, P < 0.01, 95% confidence interval CI = 1.02-1.06 and 1.05, P = 0.02, 95% CI = 1.01-1.09, respectively). Data suggest accurate admission measures are sometimes missing especially for pulse and respiratory rates, possibly linked to manual measurement. Monitoring frequency is often low in the high risk population studied probably indicating how quality of nursing care is undermined by considerable human resource shortages.
Ogero, Morris; Ayieko, Philip; Makone, Boniface; Julius, Thomas; Malla, Lucas; Oliwa, Jacquie; Irimu, Grace; English, Mike
2018-01-01
Background Measurement and correct interpretation of vital signs is part of routine clinical care. Repeated measurement enhances early recognition of deterioration, may help prevent morbidity and mortality and is a standard of care in most countries. Objective To examine documentation of vital signs by clinicians for admissions to paediatric wards in Kenyan hospitals, to describe monitoring frequency by nurses and explore factors influencing frequency. Methods Vital signs information (temperature, respiratory and pulse rate) for the first 48 hours of admission was collected from case records of children admitted with non-surgical conditions to 13 Kenyan county hospitals between September 2013 and April 2016. A mixed effect negative binomial regression model was used to explore whether the severity of illness (indicated by danger signs or severe diagnostic episodes) is associated with increased vital signs observation frequency. Results We examined 54 800 admission episodes with an overall mortality 6.1%. Nurse to bed ratios were very low (1:10 to 1:41 across hospitals). Admitting clinicians documented all or no vital signs in 57.0% and 8.4% cases respectively. For respiratory and pulse rates there was pronounced even end-digit preference (an indicator of incorrect information) and high frequency recording of specific values (P < 0.001) suggesting approximation. Monitoring frequency was explored in 41 738 children. Those with inpatient stays ≥48 hours were expected to have a vital signs count of 18, hospitals varied but most did not achieve this benchmark (median 9, range 2-30). There were clinically small but significant associations between vital signs count and presence of multiple severe illnesses or presence of severe pallor (adjusted relative risk ratio = 1.04, P < 0.01, 95% confidence interval CI = 1.02-1.06 and 1.05, P = 0.02, 95% CI = 1.01-1.09, respectively). Conclusions Data suggest accurate admission measures are sometimes missing especially for pulse and respiratory rates, possibly linked to manual measurement. Monitoring frequency is often low in the high risk population studied probably indicating how quality of nursing care is undermined by considerable human resource shortages. PMID:29497504
Dennhardt, Andrew J.; Duerr, Adam E.; Brandes, David; Katzner, Todd
2017-01-01
Estimates of population abundance are important to wildlife management and conservation. However, it can be difficult to characterize the numbers of broadly distributed, low-density, and elusive bird species. Although Golden Eagles (Aquila chrysaetos) are rare, difficult to detect, and broadly distributed, they are concentrated during their autumn migration at monitoring sites in eastern North America. We used hawk-count data collected by citizen scientists in a virtual mark–recapture modeling analysis to estimate the numbers of Golden Eagles that migrate in autumn along Kittatinny Ridge, an Important Bird Area in Pennsylvania, USA. In order to evaluate the sensitivity of our abundance estimates to variation in eagle capture histories, we applied candidate models to 8 different sets of capture histories, constructed with or without age-class information and using known mean flight speeds 6 1, 2, 4, or 6 SE for eagles to travel between hawk-count sites. Although some abundance estimates were produced by models that poorly fitted the data (ĉ > 3.0), 2 sets of population estimates were produced by acceptably performing models (cˆ less than or equal to 3.0). Application of these models to count data from November, 2002–2011, suggested a mean population abundance of 1,354 6 117 SE (range: 873–1,938). We found that Golden Eagles left the ridgeline at different rates and in different places along the route, and that typically ,50% of individuals were detected at the hawk-count sites. Our study demonstrates a useful technique for estimating population abundance that may be applicable to other migrant species that are repeatedly detected at multiple monitoring sites along a topographic diversion or leading line.
Xing, Jian; Burkom, Howard; Tokars, Jerome
2011-12-01
Automated surveillance systems require statistical methods to recognize increases in visit counts that might indicate an outbreak. In prior work we presented methods to enhance the sensitivity of C2, a commonly used time series method. In this study, we compared the enhanced C2 method with five regression models. We used emergency department chief complaint data from US CDC BioSense surveillance system, aggregated by city (total of 206 hospitals, 16 cities) during 5/2008-4/2009. Data for six syndromes (asthma, gastrointestinal, nausea and vomiting, rash, respiratory, and influenza-like illness) was used and was stratified by mean count (1-19, 20-49, ≥50 per day) into 14 syndrome-count categories. We compared the sensitivity for detecting single-day artificially-added increases in syndrome counts. Four modifications of the C2 time series method, and five regression models (two linear and three Poisson), were tested. A constant alert rate of 1% was used for all methods. Among the regression models tested, we found that a Poisson model controlling for the logarithm of total visits (i.e., visits both meeting and not meeting a syndrome definition), day of week, and 14-day time period was best. Among 14 syndrome-count categories, time series and regression methods produced approximately the same sensitivity (<5% difference) in 6; in six categories, the regression method had higher sensitivity (range 6-14% improvement), and in two categories the time series method had higher sensitivity. When automated data are aggregated to the city level, a Poisson regression model that controls for total visits produces the best overall sensitivity for detecting artificially added visit counts. This improvement was achieved without increasing the alert rate, which was held constant at 1% for all methods. These findings will improve our ability to detect outbreaks in automated surveillance system data. Published by Elsevier Inc.
Hahn, Robert G
2017-01-01
A high number of blood cells increases the viscosity of the blood. The present study explored whether variations in blood cell counts are relevant to the distribution and elimination of infused crystalloid fluid. On three different occasions, 10 healthy male volunteers received an intravenous infusion of 25mL/kg of Ringer's acetate, Ringer's lactate, and isotonic saline over 30min. Blood hemoglobin and urinary excretion were monitored for 4h and used as input in a two-volume kinetic model, using nonlinear mixed effects software. The covariates used in the kinetic model were red blood cell and platelet counts, the total leukocyte count, the use of isotonic saline, and the arterial pressure. Red blood cell and platelet counts in the upper end of the normal range were associated with a decreased rate of distribution and redistribution of crystalloid fluid. Simulations showed that high counts were correlated with volume expansion of the peripheral (interstitial) fluid space, while the plasma volume was less affected. In contrast, the total leukocyte count had no influence on the distribution, redistribution, or elimination. The use of isotonic saline caused a transient reduction in the systolic arterial pressure (P<0.05) and doubled the half-life of infused fluid in the body when compared to the two Ringer solutions. Isotonic saline did not decrease the serum potassium concentration, despite the fact that saline is potassium-free. High red blood cell and platelet counts are associated with peripheral accumulation of infused crystalloid fluid. Copyright © 2017 The Lithuanian University of Health Sciences. Production and hosting by Elsevier Sp. z o.o. All rights reserved.
Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.
Klumpp, John; Brandl, Alexander
2015-03-01
A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.
JoAnn M. Hanowski; Gerald J. Niemi
1995-01-01
We established bird monitoring programs in two regions of Minnesota: the Chippewa National Forest and the Superior National Forest. The experimental design defined forest cover types as strata in which samples of forest stands were randomly selected. Subsamples (3 point counts) were placed in each stand to maximize field effort and to assess within-stand and between-...
Recommended methods for monitoring change in bird populations by counting and capture of migrants
David J. T. Hussell; C. John Ralph
2005-01-01
Counts and banding captures of spring or fall migrants can generate useful information on the status and trends of the source populations. To do so, the counts and captures must be taken and recorded in a standardized and consistent manner. We present recommendations for field methods for counting and capturing migrants at intensively operated sites, such as bird...
Kathryn L. Purcell; Sylvia R. Mori; Mary K. Chase
2005-01-01
We used data from two oak-woodland sites in California to develop guidelines for the design of bird monitoring programs using point counts. We used power analysis to determine sample size adequacy when varying the number of visits, count stations, and years for examining trends in abundance. We assumed an overdispersed Poisson distribution for count data, with...
Dasgupta, Kaberi; Rosenberg, Ellen; Joseph, Lawrence; Cooke, Alexandra B; Trudeau, Luc; Bacon, Simon L; Chan, Deborah; Sherman, Mark; Rabasa-Lhoret, Rémi; Daskalopoulou, Stella S
2017-05-01
There are few proven strategies to enhance physical activity and cardiometabolic profiles in patients with type 2 diabetes and hypertension. We examined the effects of physician-delivered step count prescriptions and monitoring. Participants randomized to the active arm were provided with pedometers and they recorded step counts. Over a 1-year period, their physicians reviewed their records and provided a written step count prescription at each clinic visit. The overall goal was a 3000 steps/day increase over 1 year (individualized rate of increase). Control arm participants were advised to engage in physical activity 30 to 60 min/day. We evaluated effects on step counts, carotid femoral pulse wave velocity (cfPWV, primary) and other cardiometabolic indicators including haemoglobin A1c in diabetes (henceforth abbreviated as A1c) and Homeostasis Model Assessment-Insulin Resistance (HOMA-IR) in participants not receiving insulin therapy. A total of 79% completed final evaluations (275/347; mean age, 60 years; SD, 11). Over 66% of participants had type 2 diabetes and over 90% had hypertension. There was a net 20% increase in steps/day in active vs control arm participants (1190; 95% CI, 550-1840). Changes in cfPWV were inconclusive; active vs control arm participants with type 2 diabetes experienced a decrease in A1c (-0.38%; 95% CI, -0.69 to -0.06). HOMA-IR also declined in the active arm vs the control arm (ie, assessed in all participants not treated with insulin; -0.96; 95% CI, -1.72 to -0.21). A simple physician-delivered step count prescription strategy incorporated into routine clinical practice led to a net 20% increase in step counts; however, this was below the 3000 steps/day targeted increment. While conclusive effects on cfPWV were not observed, there were improvements in both A1c and insulin sensitivity. Future studies will evaluate an amplified intervention to increase impact. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.
Evaluation of three portable samplers for monitoring airborne fungi
NASA Technical Reports Server (NTRS)
Mehta, S. K.; Mishra, S. K.; Pierson, D. L.
1996-01-01
Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.
A semi-automated method of monitoring dam passage of American Eels Anguilla rostrata
Welsh, Stuart A.; Aldinger, Joni L.
2014-01-01
Fish passage facilities at dams have become an important focus of fishery management in riverine systems. Given the personnel and travel costs associated with physical monitoring programs, automated or semi-automated systems are an attractive alternative for monitoring fish passage facilities. We designed and tested a semi-automated system for eel ladder monitoring at Millville Dam on the lower Shenandoah River, West Virginia. A motion-activated eel ladder camera (ELC) photographed each yellow-phase American Eel Anguilla rostrata that passed through the ladder. Digital images (with date and time stamps) of American Eels allowed for total daily counts and measurements of eel TL using photogrammetric methods with digital imaging software. We compared physical counts of American Eels with camera-based counts; TLs obtained with a measuring board were compared with TLs derived from photogrammetric methods. Data from the ELC were consistent with data obtained by physical methods, thus supporting the semi-automated camera system as a viable option for monitoring American Eel passage. Time stamps on digital images allowed for the documentation of eel passage time—data that were not obtainable from physical monitoring efforts. The ELC has application to eel ladder facilities but can also be used to monitor dam passage of other taxa, such as crayfishes, lampreys, and water snakes.
Lyons, James E.; Andrew, Royle J.; Thomas, Susan M.; Elliott-Smith, Elise; Evenson, Joseph R.; Kelly, Elizabeth G.; Milner, Ruth L.; Nysewander, David R.; Andres, Brad A.
2012-01-01
Large-scale monitoring of bird populations is often based on count data collected across spatial scales that may include multiple physiographic regions and habitat types. Monitoring at large spatial scales may require multiple survey platforms (e.g., from boats and land when monitoring coastal species) and multiple survey methods. It becomes especially important to explicitly account for detection probability when analyzing count data that have been collected using multiple survey platforms or methods. We evaluated a new analytical framework, N-mixture models, to estimate actual abundance while accounting for multiple detection biases. During May 2006, we made repeated counts of Black Oystercatchers (Haematopus bachmani) from boats in the Puget Sound area of Washington (n = 55 sites) and from land along the coast of Oregon (n = 56 sites). We used a Bayesian analysis of N-mixture models to (1) assess detection probability as a function of environmental and survey covariates and (2) estimate total Black Oystercatcher abundance during the breeding season in the two regions. Probability of detecting individuals during boat-based surveys was 0.75 (95% credible interval: 0.42–0.91) and was not influenced by tidal stage. Detection probability from surveys conducted on foot was 0.68 (0.39–0.90); the latter was not influenced by fog, wind, or number of observers but was ~35% lower during rain. The estimated population size was 321 birds (262–511) in Washington and 311 (276–382) in Oregon. N-mixture models provide a flexible framework for modeling count data and covariates in large-scale bird monitoring programs designed to understand population change.
Precision determination of absolute neutron flux
Yue, A. T.; Anderson, E. S.; Dewey, M. S.; ...
2018-06-08
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performedmore » to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.« less
Precision determination of absolute neutron flux
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, A. T.; Anderson, E. S.; Dewey, M. S.
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performedmore » to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.« less
Roy, Helen E.; Baxter, Elizabeth; Saunders, Aoine; Pocock, Michael J. O.
2016-01-01
Background Recently there has been increasing focus on monitoring pollinating insects, due to concerns about their declines, and interest in the role of volunteers in monitoring pollinators, particularly bumblebees, via citizen science. Methodology / Principal Findings The Big Bumblebee Discovery was a one-year citizen science project run by a partnership of EDF Energy, the British Science Association and the Centre for Ecology & Hydrology which sought to assess the influence of the landscape at multiple scales on the diversity and abundance of bumblebees. Timed counts of bumblebees (Bombus spp.; identified to six colour groups) visiting focal plants of lavender (Lavendula spp.) were carried out by about 13 000 primary school children (7–11 years old) from over 4000 schools across the UK. 3948 reports were received totalling 26 868 bumblebees. We found that while the wider landscape type had no significant effect on reported bumblebee abundance, the local proximity to flowers had a significant effect (fewer bumblebees where other flowers were reported to be >5m away from the focal plant). However, the rate of mis-identifcation, revealed by photographs uploaded by participants and a photo-based quiz, was high. Conclusions / Significance Our citizen science results support recent research on the importance of local flocal resources on pollinator abundance. Timed counts of insects visiting a lure plant is potentially an effective approach for standardised pollinator monitoring, engaging a large number of participants with a simple protocol. However, the relatively high rate of mis-identifications (compared to reports from previous pollinator citizen science projects) highlights the importance of investing in resources to train volunteers. Also, to be a scientifically valid method for enquiry, citizen science data needs to be sufficiently high quality, so receiving supporting evidence (such as photographs) would allow this to be tested and for records to be verified. PMID:26985824
Automated biodosimetry using digital image analysis of fluorescence in situ hybridization specimens.
Castleman, K R; Schulze, M; Wu, Q
1997-11-01
Fluorescence in situ hybridization (FISH) of metaphase chromosome spreads is valuable for monitoring the radiation dose to circulating lymphocytes. At low dose levels, the number of cells that must be examined to estimate aberration frequencies is quite large. An automated microscope that can perform this analysis autonomously on suitably prepared specimens promises to make practical the large-scale studies that will be required for biodosimetry in the future. This paper describes such an instrument that is currently under development. We use metaphase specimens in which the five largest chromosomes have been hybridized with different-colored whole-chromosome painting probes. An automated multiband fluorescence microscope locates the spreads and counts the number of chromosome components of each color. Digital image analysis is used to locate and isolate the cells, count chromosome components, and estimate the proportions of abnormal cells. Cells exhibiting more than two chromosomal fragments in any color correspond to a clastogenic event. These automatically derived counts are corrected for statistical bias and used to estimate the overall rate of chromosome breakage. Overlap of fluorophore emission spectra prohibits isolation of the different chromosomes into separate color channels. Image processing effectively isolates each fluorophore to a single monochrome image, simplifying the task of counting chromosome fragments and reducing the error in the algorithm. Using proportion estimation, we remove the bias introduced by counting errors, leaving accuracy restricted by sample size considerations alone.
Relationship between salivary flow rates and Candida albicans counts.
Navazesh, M; Wood, G J; Brightman, V J
1995-09-01
Seventy-one persons (48 women, 23 men; mean age, 51.76 years) were evaluated for salivary flow rates and Candida albicans counts. Each person was seen on three different occasions. Samples of unstimulated whole, chewing-stimulated whole, acid-stimulated parotid, and candy-stimulated parotid saliva were collected under standardized conditions. An oral rinse was also obtained and evaluated for Candida albicans counts. Unstimulated and chewing-stimulated whole flow rates were negatively and significantly (p < 0.001) related to the Candida counts. Unstimulated whole saliva significantly (p < 0.05) differed in persons with Candida counts of 0 versus <500 versus < or = 500. Chewing-stimulated saliva was significantly (p < 0.05) different in persons with 0 counts compared with those with a > or = 500 count. Differences in stimulated parotid flow rates were not significant among different levels of Candida counts. The results of this study reveal that whole saliva is a better predictor than parotid saliva in identification of persons with high Candida albicans counts.
Erhabor, O; Ejele, O A; Nwauche, C A; Buseri, F I
2005-01-01
Haematologic abnormalities are among the most common manifestations of advanced human immunodeficiency virus (HIV) infection and acquired immunodeficiency syndrome (AIDS). A specific diagnosis of cause, severity and mechanism of cytopenia should be sought because of specific treatments or intervention may be indicated for its correction. This study was to determine some haematological parameters in HIV/AIDS infected Nigerians. One hundred HIV/AIDS infected previously antiretroviral naïve adult Nigerians, aged 18-58 year (males 47 and females 53) consisting of 88 symptomatic and 12 asymptomatic patients recruited into the antiretroviral pilot project in the Haematology department of the University of Port Harcourt Teaching Hospital between June 2002 to July 2003 were studied. Haematological parameters of hemoglobin, white cell count, platelet count, erythrocyte sedimentation rate and differential leucocyte count were determined. Data was analyzed using a multipurpose statistical package version 9 SPSS. The mean haemoglobin was 10.25 +/- 1.97 g/dl (range 6.31-14.2 g/dl), severe anaemia occurred in 80% of subjects while 20% were non-anaemic. Haemoglobin values was found positively correlated to lymphocyte count (r = .319, P = 0.01) and inversely correlated to ESR (r = -.343, P = 0.01) and neutrophil count (r = -.343, P = 0.01). Red cell morphology was variable with majority normochromic and normocytic (64%) and 36% showing hypochromia and anisopoikilocytosis. The mean total WBC count was 4.51 +/- 1.82 x 10(9)/l (range 0.9-8.2 x 10(9)/l). Leucopaenia occurred in 10/100 (10%) of study population. Total white cell count showed a significant inverse correlation to lymphocyte count (r = -.326, P = 0.01). The mean neutrophil count was 2.32 +/- 1.58 x 10(9)/l (range 0.00-5.48). Neutropaenia occurred in 24% of subjects. Neutrophil count showed a significant positive correlation with total white cell count (r = .314, P = 0.01) and a negative correlation with lymphocyte count (r = -.982, P = 0.01). Striking eosinophilia occurred in 3% of subjects. The mean platelet count was 170.07 +/- 49.03 x 10(9)/l (range 72-158 x 268 x 10(9)/l). Thrombocytopaenia occurred in 10/100 (10%) of subjects. The mean erythrocyte sedimentation rate was higher than that in healthy Africans (mean 78.87 +/- 39.33mm fall/hour (range 0.2-158mm fall/hour). Observation from this study will serve as a guide to clinicians caring for HIV patients in taking rational decision on haematological complications of HIV infection. This constitutes further evidence of the need for routine monitoring of some haematological parameters of HIV/AIDS infected Africans and before commencement of highly active antiretroviral therapy to ensure that mortality and morbidity are minimized and quality of life optimized.
Lang, Andreas; Dolek, Matthias; Theißen, Bernhard; Zapp, Andreas
2011-01-01
Butterflies and moths (Lepidoptera) have been suggested for the environmental monitoring of genetically modified (GM) crops due to their suitability as ecological indicators, and because of the possible adverse impact of the cultivation of current transgenic crops. The German Association of Engineers (VDI) has developed guidelines for the standardized monitoring of Lepidoptera describing the use of light traps for adult moths, transect counts for adult butterflies, and visual search for larvae. The guidelines suggest recording adults of Crambid Snout Moths during transect counts in addition to butterflies, and present detailed protocols for the visual search of larvae. In a field survey in three regions of Germany, we tested the practicability and effort-benefit ratio of the latter two VDI approaches. Crambid Snout Moths turned out to be suitable and practical indicators, which can easily be recorded during transect counts. They were present in 57% of the studied field margins, contributing a substantial part to the overall Lepidoptera count, thus providing valuable additional information to the monitoring results. Visual search of larvae generated results in an adequate effort-benefit ratio when searching for lepidopteran larvae of common species feeding on nettles. Visual search for larvae living on host plants other than nettles was time-consuming and yielded much lower numbers of recorded larvae. Beating samples of bushes and trees yielded a higher number of species and individuals. This method is especially appropriate when hedgerows are sampled, and was judged to perform intermediate concerning the relationship between invested sampling effort and obtained results for lepidopteran larvae. In conclusion, transect counts of adult Crambid Moths and recording of lepidopteran larvae feeding on nettles are feasible additional modules for an environmental monitoring of GM crops. Monitoring larvae living on host plants other than nettles and beating samples of bushes and trees can be used as a supplementary tool if necessary or desired. PMID:26467735
Seismic intrusion detector system
Hawk, Hervey L.; Hawley, James G.; Portlock, John M.; Scheibner, James E.
1976-01-01
A system for monitoring man-associated seismic movements within a control area including a geophone for generating an electrical signal in response to seismic movement, a bandpass amplifier and threshold detector for eliminating unwanted signals, pulse counting system for counting and storing the number of seismic movements within the area, and a monitoring system operable on command having a variable frequency oscillator generating an audio frequency signal proportional to the number of said seismic movements.
ERIC Educational Resources Information Center
McAdam, David B.; And Others
1993-01-01
A self-management approach (utilizing self-counting of behaviors, corrective verbal feedback, and contingent verbal praise) was effectively used to reduce stereotypical body rocking in a congenitally blind young adult. Positive results were maintained, with replacement of overt counting with covert counting and immediate with delayed feedback as…
Continuous event monitoring via a Bayesian predictive approach.
Di, Jianing; Wang, Daniel; Brashear, H Robert; Dragalin, Vladimir; Krams, Michael
2016-01-01
In clinical trials, continuous monitoring of event incidence rate plays a critical role in making timely decisions affecting trial outcome. For example, continuous monitoring of adverse events protects the safety of trial participants, while continuous monitoring of efficacy events helps identify early signals of efficacy or futility. Because the endpoint of interest is often the event incidence associated with a given length of treatment duration (e.g., incidence proportion of an adverse event with 2 years of dosing), assessing the event proportion before reaching the intended treatment duration becomes challenging, especially when the event onset profile evolves over time with accumulated exposure. In particular, in the earlier part of the study, ignoring censored subjects may result in significant bias in estimating the cumulative event incidence rate. Such a problem is addressed using a predictive approach in the Bayesian framework. In the proposed approach, experts' prior knowledge about both the frequency and timing of the event occurrence is combined with observed data. More specifically, during any interim look, each event-free subject will be counted with a probability that is derived using prior knowledge. The proposed approach is particularly useful in early stage studies for signal detection based on limited information. But it can also be used as a tool for safety monitoring (e.g., data monitoring committee) during later stage trials. Application of the approach is illustrated using a case study where the incidence rate of an adverse event is continuously monitored during an Alzheimer's disease clinical trial. The performance of the proposed approach is also assessed and compared with other Bayesian and frequentist methods via simulation. Copyright © 2015 John Wiley & Sons, Ltd.
Westfall, J M; McGloin, J
2001-05-01
Ischemic heart disease is the leading cause of death in the United States. Recent studies report inconsistent findings on the changes in the incidence of hospitalizations for ischemic heart disease. These reports have relied primarily on hospital discharge data. Preliminary data suggest that a significant percentage of patients suffering acute myocardial infarction (MI) in rural communities are transferred to urban centers for care. Patients transferred to a second hospital may be counted twice for one episode of ischemic heart disease. To describe the impact of double counting and transfer bias on the estimation of incidence rates and outcomes of ischemic heart disease, specifically acute MI, in the United States. Analysis of state hospital discharge data from Kansas, Colorado (State Inpatient Database [SID]), Nebraska, Arizona, New Jersey, Michigan, Pennsylvania, and Illinois (SID) for the years 1995 to 1997. A matching algorithm was developed for hospital discharges to determine patients counted twice for one episode of ischemic heart disease. Validation of our matching algorithm. Patients reported to have suffered ischemic heart disease (ICD9 codes 410-414, 786.5). Number of patients counted twice for one episode of acute MI. It is estimated that double count rates range from 10% to 15% for all states and increased over the 3 years. Moderate sized rural counties had the highest estimated double count rates at 15% to 20% with a few counties having estimated double count rates a high as 35% to 50%. Older patients and females were less likely to be double counted (P <0.05). Double counting patients has resulted in a significant overestimation in the incidence rate for hospitalization for acute MI. Correction of this double counting reveals a significantly lower incidence rate and a higher in-hospital mortality rate for acute MI. Transferred patients differ significantly from nontransferred patients, introducing significant bias into MI outcome studies. Double counting and transfer bias should be considered when conducting and interpreting research on ischemic heart disease, particularly in rural regions.
DOT National Transportation Integrated Search
1995-02-01
This guide is designed to provide direction on the monitoring of traffic characteristics. It begins with a discussion of the structure of traffic characteristics monitoring and traffic counting. The next two sections cover vehicle classification and ...
Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes.
Storie, Ian; Sawle, Alex; Goodfellow, Karen; Whitby, Liam; Granger, Vivian; Ward, Rosalie Y; Peel, Janet; Smart, Theresa; Reilly, John T; Barnett, David
2004-01-01
The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis. Copyright 2003 Wiley-Liss, Inc.
Palchaudhuri, Sonali; Tweya, Hannock; Hosseinipour, Mina
2014-06-01
The 2011 Malawi HIV guidelines promote CD4 monitoring for pre-ART assessment and considering HIVRNA monitoring for ART response assessment, while some clinics used CD4 for both. We assessed clinical ordering practices as compared to guidelines, and determined whether the samples were successfully and promptly processed. We conducted a retrospective review of all patients seen in from August 2010 through July 2011,, in two urban HIV-care clinics that utilized 6-monthly CD4 monitoring regardless of ART status. We calculated the percentage of patients on whom clinicians ordered CD4 or HIVRNA analysis. For all samples sent, we determined rates of successful lab-processing, and mean time to returned results. Of 20581 patients seen, 8029 (39%) had at least one blood draw for CD4 count. Among pre-ART patients, 2668/2844 (93.8%) had CD4 counts performed for eligibility. Of all CD4 samples sent, 8082/9207 (89%) samples were successfully processed. Of those, mean time to processing was 1.6 days (s.d 1.5) but mean time to results being available to clinician was 9.3 days (s.d. 3.7). Regarding HIVRNA, 172 patients of 17737 on ART had a blood draw and only 118/213 (55%) samples were successfully processed. Mean processing time was 39.5 days (s.d. 21.7); mean time to results being available to clinician was 43.1 days (s.d. 25.1). During the one-year evaluated, there were multiple lapses in processing HIVRNA samples for up to 2 months. Clinicians underutilize CD4 and HIVRNA as monitoring tools in HIV care. Laboratory processing failures and turnaround times are unacceptably high for viral load analysis. Alternative strategies need to be considered in order to meet laboratory monitoring needs.
Wright, Stephen; Boyd, Mark A.; Yunihastuti, Evy; Law, Matthew; Sirisanthana, Thira; Hoy, Jennifer; Pujari, Sanjay; Lee, Man Po; Petoumenos, Kathy
2013-01-01
Background In the Asia-Pacific region many countries have adopted the WHO’s public health approach to HIV care and treatment. We performed exploratory analyses of the factors associated with first major modification to first-line combination antiretroviral therapy (ART) in resource-rich and resource-limited countries in the region. Methods We selected treatment naive HIV-positive adults from the Australian HIV Observational Database (AHOD) and the TREAT Asia HIV Observational Database (TAHOD). We dichotomised each country’s per capita income into high/upper-middle (T-H) and lower-middle/low (T-L). Survival methods stratified by income were used to explore time to first major modification of first-line ART and associated factors. We defined a treatment modification as either initiation of a new class of antiretroviral (ARV) or a substitution of two or more ARV agents from within the same ARV class. Results A total of 4250 patients had 961 major modifications to first-line ART in the first five years of therapy. The cumulative incidence (95% CI) of treatment modification was 0.48 (0.44–0.52), 0.33 (0.30–0.36) and 0.21 (0.18–0.23) for AHOD, T-H and T-L respectively. We found no strong associations between typical patient characteristic factors and rates of treatment modification. In AHOD, relative to sites that monitor twice-yearly (both CD4 and HIV RNA-VL), quarterly monitoring corresponded with a doubling of the rate of treatment modifications. In T-H, relative to sites that monitor once-yearly (both CD4 and HIV RNA-VL), monitoring twice-yearly corresponded to a 1.8 factor increase in treatment modifications. In T-L, no sites on average monitored both CD4 & HIV RNA-VL concurrently once-yearly. We found no differences in rates of modifications for once- or twice-yearly CD4 count monitoring. Conclusions Low-income countries tended to have lower rates of major modifications made to first-line ART compared to higher-income countries. In higher-income countries, an increased rate of RNA-VL monitoring was associated with increased modifications to first-line ART. PMID:23840312
Wright, Stephen; Boyd, Mark A; Yunihastuti, Evy; Law, Matthew; Sirisanthana, Thira; Hoy, Jennifer; Pujari, Sanjay; Lee, Man Po; Petoumenos, Kathy
2013-01-01
In the Asia-Pacific region many countries have adopted the WHO's public health approach to HIV care and treatment. We performed exploratory analyses of the factors associated with first major modification to first-line combination antiretroviral therapy (ART) in resource-rich and resource-limited countries in the region. We selected treatment naive HIV-positive adults from the Australian HIV Observational Database (AHOD) and the TREAT Asia HIV Observational Database (TAHOD). We dichotomised each country's per capita income into high/upper-middle (T-H) and lower-middle/low (T-L). Survival methods stratified by income were used to explore time to first major modification of first-line ART and associated factors. We defined a treatment modification as either initiation of a new class of antiretroviral (ARV) or a substitution of two or more ARV agents from within the same ARV class. A total of 4250 patients had 961 major modifications to first-line ART in the first five years of therapy. The cumulative incidence (95% CI) of treatment modification was 0.48 (0.44-0.52), 0.33 (0.30-0.36) and 0.21 (0.18-0.23) for AHOD, T-H and T-L respectively. We found no strong associations between typical patient characteristic factors and rates of treatment modification. In AHOD, relative to sites that monitor twice-yearly (both CD4 and HIV RNA-VL), quarterly monitoring corresponded with a doubling of the rate of treatment modifications. In T-H, relative to sites that monitor once-yearly (both CD4 and HIV RNA-VL), monitoring twice-yearly corresponded to a 1.8 factor increase in treatment modifications. In T-L, no sites on average monitored both CD4 & HIV RNA-VL concurrently once-yearly. We found no differences in rates of modifications for once- or twice-yearly CD4 count monitoring. Low-income countries tended to have lower rates of major modifications made to first-line ART compared to higher-income countries. In higher-income countries, an increased rate of RNA-VL monitoring was associated with increased modifications to first-line ART.
Increasing X-Ray Brightness of HBL Source 1ES 1727+650
NASA Astrophysics Data System (ADS)
Kapanadze, Bidzina
2017-02-01
The nearby TeV-detected HBL object 1ES 1727+502 (1Zw 187, z=0.055) has been targeted 111 times by X-ray Telescope (XRT) onboard Swift since 2010 April 2. During this monitoring, the 0.3-10 keV count rate varied by a factor of 17.4 (see http://www.swift.psu.edu/monitoring/source.php?source=QSOB1727+502) and showed a prolonged X-ray flaring activity during 2015 March - 2016 February, revealed mainly via the Target of Opportunity observations performed in the framework of our request of different urgencies (Request Number 6571, 6606, 6717, 6809, 6927, 7322, 7355, 7379, 7390, 7404, 7430, 7441, 7516, 7565; see Kapanadze et al. 2015, Atel #8224, #7342).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, A K; Koniczek, M; Antonuk, L E
Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailedmore » circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.« less
Beaulieu, Robert; López-Mondéjar, Rubén; Tittarelli, Fabio; Ros, Margarita; Pascual, José Antonio
2011-02-01
To ensure proper use of Trichoderma harzianum in agriculture, accurate data must be obtained in population monitoring. The effectiveness of qRT-PCR to quantify T. harzianum in different growing media was compared to the commonly used techniques of colony counting and qPCR. Results showed that plate counting and qPCR offered similar T. harzianum quantification patterns of an initial rapid increase in fungal population that decreased over time. However, data from qRT-PCR showed a population curve of active T. harzianum with a delayed onset of initial growth which then increased throughout the experiment. Results demonstrated that T. harzianum can successfully grow in these media and that qRT-PCR can offer a more distinct representation of active T. harzianum populations. Additionally, compost amended with T. harzianum exhibited a lower Fusarium oxysporum infection rate (67%) and lower percentage of fresh weight loss (11%) in comparison to amended peat (90% infection rate, 23% fresh weight loss). Copyright © 2010 Elsevier Ltd. All rights reserved.
Kautz, F M; Nickerson, S C; Ely, L O
2014-08-01
This investigation evaluated the efficacy of a bacterin in reducing the prevalence of staphylococcal mastitis and somatic cell counts (SCC) in a dairy goat herd. Does were vaccinated or left as controls, and the levels of mastitis and SCC monitored over 18 months. Staphylococcus caprae (42.5%), S. xylosus (15.1%), and S. simulans (10.0%) were the predominant causes of intramammary infections (IMI). The infection rate was 1.64 IMI/doe among vaccinates, which tended to be lower (P < 0.12) than controls (2.67 IMI/doe). The spontaneous cure rate of IMI after immunization was 1.28 cures/doe in vaccinates, which was higher than controls (0.6 cures/doe; P < 0.043). Average SCC of milk samples from vaccinates tended to be lower than that of controls (1274 × 10(3)/ml vs. 1529 × 10(3)/ml, respectively) (P < 0.10). Results support the continued study of mastitis vaccines for use in managing staphylococcal mastitis and SCC in dairy goats. Published by Elsevier Ltd.
A plan for the North American Bat Monitoring Program (NABat)
Loeb, Susan C.; Rodhouse, Thomas J.; Ellison, Laura E.; Lausen, Cori L.; Reichard, Jonathan D.; Irvine, Kathryn M.; Ingersoll, Thomas E.; Coleman, Jeremy; Thogmartin, Wayne E.; Sauer, John R.; Francis, Charles M.; Bayless, Mylea L.; Stanley, Thomas R.; Johnson, Douglas H.
2015-01-01
The purpose of the North American Bat Monitoring Program (NABat) is to create a continent-wide program to monitor bats at local to rangewide scales that will provide reliable data to promote effective conservation decisionmaking and the long-term viability of bat populations across the continent. This is an international, multiagency program. Four approaches will be used to gather monitoring data to assess changes in bat distributions and abundances: winter hibernaculum counts, maternity colony counts, mobile acoustic surveys along road transects, and acoustic surveys at stationary points. These monitoring approaches are described along with methods for identifying species recorded by acoustic detectors. Other chapters describe the sampling design, the database management system (Bat Population Database), and statistical approaches that can be used to analyze data collected through this program.
Observations by Juno's Radiation Monitoring Investigation During the First Year at Jupiter
NASA Astrophysics Data System (ADS)
Becker, H. N.; Adumitroaie, V.; Alexander, J. W.; Daubar, I.; Joergensen, J. L.; Denver, T.; Benn, M.; Adriani, A.; Mura, A.; Cicchetti, A.; Noschese, R.; Connerney, J. E. P.; Gladstone, R.; Hue, V.; Versteeg, M.; Santos-Costa, D.; Bolton, S. J.; Levin, S.; Thorne, R. M.
2017-12-01
Juno's Radiation Monitoring (RM) Investigation measures MeV electron fluxes at Jupiter by utilizing the noise signatures of penetrating high-energy particles which are visible in images collected by Juno's heavily shielded star cameras and science instruments. Image processing is used to identify and extract the characteristic signatures of penetrating high-energy electrons and ions and derive count rates which are used to infer external integral electron flux levels [Becker, H.N., et al. (2017), Space Sci Rev, doi: 10.1007/s11214-017-0345-9; Becker H.N. et al. (2017), Geophys. Res. Lett., 44, doi:10.1002/2017GL073091]. The count rate data from each RM instrument represents detection of electrons from within a broad energy channel (e.g. > 5 MeV or > 10 MeV electron sensitivity, determined using Geant4 shielding analysis). Simultaneous observations by the instruments therefore allow study of the external spectra where coordinated measurements are achieved. The spacecraft Stellar Reference Unit (SRU), the Magnetic Field Investigation's Advanced Stellar Compass (ASC) camera head D, and the Jovian Infrared Auroral Mapper (JIRAM) infrared imager are the primary instruments used in RM's collaborative observation campaigns. Penetrating particle signatures and trends across a broader range of Juno instruments and spacecraft housekeeping data also contribute to the analysis. This paper presents an overview of RM measurements of the Jovian high energy particle environment observed during the first eight science orbits of Juno's prime mission.
Antithyroid drug-induced agranulocytosis.
Sun, Ming-Tsung; Tsai, Chen-Hao; Shih, Kuang-Chung
2009-08-01
Antithyroid drugs are widely used to treat hyperthyroidism, especially Graves' disease, but they tend to cause agranulocytosis, which increases the mortality rate. Granulocyte colony-stimulating factor decreases the duration of recovery from agranulocytosis. We retrospectively studied cases of antithyroid drug-induced agranulocytosis over the past 10 years in a northern Taiwan medical center. A clinical evaluation was conducted, including a review of complete blood cell counts and differential counts. Four cases were included in this analysis. Agranulocytosis persisted in 2 cases despite a change in therapy from propylthiouracil to methimazole. Fever, sore throat, and diarrhea were common symptoms of agranulocytosis. Initial white blood cell counts ranged from 450 to 1,710/microL. Only 1 case had a positive result from a throat swab culture (Staphylococcus aureus). Three of 4 cases received granulocyte colony-stimulating factor therapy, and the recovery time ranged from 3 to 13 days. All of the patients recovered from agranulocytosis. We concluded that: (1) conducting a routine complete blood cell count is beneficial in alerting caregivers to the possibility of agranulocytosis; (2) educating patients about the common symptoms of agranulocytosis may contribute to an early diagnosis; (3) providing granulocyte colony-stimulating factor therapy to patients results in good prognosis; and (4) monitoring for cross-reactions between drugs should be performed to prevent further episodes of agranulocytosis.
Initial lymphocyte count and low BMI may affect fingolimod-induced lymphopenia.
Warnke, Clemens; Dehmel, Thomas; Ramanujam, Ryan; Holmen, Carolina; Nordin, Nina; Wolfram, Kathleen; Leussink, Verena I; Hartung, Hans-Peter; Olsson, Tomas; Kieseier, Bernd C
2014-12-02
To assess whether pretreatment-lymphocyte counts, treatment before fingolimod, age, sex, or body mass index (BMI) affects the risk of fingolimod-induced lymphopenia in patients with relapsing-remitting multiple sclerosis (RRMS). Data were obtained from a German multicenter, single-arm, open-label study of patients with RRMS treated with fingolimod, and findings were validated in an independent Swedish national pharmacovigilance study. Four hundred eighteen patients with RRMS from Germany and 438 patients from Sweden were included. A nadir ≤0.2 × 10(9) lymphocytes/L was reached in 15% (95% confidence interval [CI] 12%-17%) of all 856 patients. Patients with lower starting lymphocyte counts (below 1.6 × 10(9)/L) and patients with BMI lower than 18.5 kg/m(2) (women only) were at higher risk of developing lymphopenia with values ≤0.2 × 10(9)/L in the combined analysis, increasing the risk in these subgroups to 26% (95% CI 20%-31%) or 46% (95% CI 23%-71%), respectively. In the German cohort, infection rates were similar in patients who developed severe lymphopenia and those who did not. Our findings suggest that patients with low baseline lymphocyte counts and underweight women in which fingolimod treatment will be initiated should possibly be monitored more closely. © 2014 American Academy of Neurology.
Gould, A Lawrence
2016-12-30
Conventional practice monitors accumulating information about drug safety in terms of the numbers of adverse events reported from trials in a drug development program. Estimates of between-treatment adverse event risk differences can be obtained readily from unblinded trials with adjustment for differences among trials using conventional statistical methods. Recent regulatory guidelines require monitoring the cumulative frequency of adverse event reports to identify possible between-treatment adverse event risk differences without unblinding ongoing trials. Conventional statistical methods for assessing between-treatment adverse event risks cannot be applied when the trials are blinded. However, CUSUM charts can be used to monitor the accumulation of adverse event occurrences. CUSUM charts for monitoring adverse event occurrence in a Bayesian paradigm are based on assumptions about the process generating the adverse event counts in a trial as expressed by informative prior distributions. This article describes the construction of control charts for monitoring adverse event occurrence based on statistical models for the processes, characterizes their statistical properties, and describes how to construct useful prior distributions. Application of the approach to two adverse events of interest in a real trial gave nearly identical results for binomial and Poisson observed event count likelihoods. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Li, Roger W.; MacKeben, Manfred; Chat, Sandy W.; Kumar, Maya; Ngo, Charlie; Levi, Dennis M.
2010-01-01
Background Much previous work on how normal aging affects visual enumeration has been focused on the response time required to enumerate, with unlimited stimulus duration. There is a fundamental question, not yet addressed, of how many visual items the aging visual system can enumerate in a “single glance”, without the confounding influence of eye movements. Methodology/Principal Findings We recruited 104 observers with normal vision across the age span (age 21–85). They were briefly (200 ms) presented with a number of well- separated black dots against a gray background on a monitor screen, and were asked to judge the number of dots. By limiting the stimulus presentation time, we can determine the maximum number of visual items an observer can correctly enumerate at a criterion level of performance (counting threshold, defined as the number of visual items at which ≈63% correct rate on a psychometric curve), without confounding by eye movements. Our findings reveal a 30% decrease in the mean counting threshold of the oldest group (age 61–85: ∼5 dots) when compared with the youngest groups (age 21–40: 7 dots). Surprisingly, despite decreased counting threshold, on average counting accuracy function (defined as the mean number of dots reported for each number tested) is largely unaffected by age, reflecting that the threshold loss can be primarily attributed to increased random errors. We further expanded this interesting finding to show that both young and old adults tend to over-count small numbers, but older observers over-count more. Conclusion/Significance Here we show that age reduces the ability to correctly enumerate in a glance, but the accuracy (veridicality), on average, remains unchanged with advancing age. Control experiments indicate that the degraded performance cannot be explained by optical, retinal or other perceptual factors, but is cortical in origin. PMID:20976149
ERIC Educational Resources Information Center
Sawchuk, Craig N.; Russo, Joan E.; Charles, Steve; Goldberg, Jack; Forquera, Ralph; Roy-Byrne, Peter; Buchwald, Dedra
2011-01-01
We examined if step-count goal setting resulted in increases in physical activity and walking compared to only monitoring step counts with pedometers among American Indian/Alaska Native elders. Outcomes included step counts, self-reported physical activity and well-being, and performance on the 6-minute walk test. Although no significant…
A complete low cost radon detection system.
Bayrak, A; Barlas, E; Emirhan, E; Kutlu, Ç; Ozben, C S
2013-08-01
Monitoring the (222)Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. Copyright © 2013 Elsevier Ltd. All rights reserved.
Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range
NASA Technical Reports Server (NTRS)
Krainak, Michael A.
2004-01-01
We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.
2012-01-01
Background Decreasing sedentary activities that involve prolonged sitting may be an important strategy to reduce obesity and other physical and psychosocial health problems in children. The first step to understanding the effect of sedentary activities on children’s health is to objectively assess these activities with a valid measurement tool. Purpose To examine the validity of the ActivPAL monitor in measuring sitting/lying, standing, and walking time, transition counts and step counts in children in a laboratory setting. Methods Twenty five healthy elementary school children (age 9.9 ± 0.3 years; BMI 18.2 ± 1.9; mean ± SD) were randomly recruited across the Auckland region, New Zealand. Children were fitted with ActivPAL monitors and observed during simulated free-living activities involving sitting/lying, standing and walking, followed by treadmill and over-ground activities at various speeds (slow, normal, fast) against video observation (criterion measure). The ActivPAL sit-to-stand and stand-to-sit transition counts and steps were also compared with video data. The accuracy of step counts measured by the ActivPAL was also compared against the New Lifestyles NL-2000 and the Yamax Digi-Walker SW-200 pedometers. Results We observed a perfect correlation between the ActivPAL monitor in time spent sitting/lying, standing, and walking in simulated free-living activities with direct observation. Correlations between the ActivPAL and video observation in total numbers of sit-to-stand and stand-to-sit transitions were high (r = 0.99 ± 0.01). Unlike pedometers, the ActivPAL did not misclassify fidgeting as steps taken. Strong correlations (r = 0.88-1.00) between ActivPAL step counts and video observation in both treadmill and over-ground slow and normal walking were also observed. During treadmill and over-ground fast walking and running, the correlations were low (r = 0.21-0.46). Conclusion The ActivPAL monitor is a valid measurement tool for assessing time spent sitting/lying, standing, and walking, sit-to-stand and stand-to-sit transition counts and step counts in slow and normal walking. The device did not measure accurately steps taken during treadmill and over-ground fast walking and running in children. PMID:23031188
500-514 N. Peshtigo Ct, May 2018, Lindsay Light Radiological Survey
maximum gamma count rate for each lift was recorded on the attached RadiationSurvey Forms. Count rates in the excavation ranged from 1,800 cpm - 5,000 cpm.No count rates were found at any time that exceeded the instrument specific thresholdlimits.
550 E. Illinois, May 2018, Lindsay Light Radiological Survey
Maximum gamma count rate for each lift was recorded on the attached RadiationSurvey Forms. Count rates in the excavation ranged from 1,250 cpm to 4,880 cpm.No count rates were found at any time that exceeded the instrument specific thresholdlimits.
Hoffmann, Christopher J; Maritz, Jean; van Zyl, Gert U
2016-02-01
CD4 count decline often triggers antiretroviral regimen switches in resource-limited settings, even when viral load testing is available. We therefore compared CD4 failure and CD4 trends in patients with viraemia with or without antiretroviral resistance. Retrospective cohort study investigating the association of HIV drug resistance with CD4 failure or CD4 trends in patients on first-line antiretroviral regimens during viraemia. Patients with viraemia (HIV RNA >1000 copies/ml) from two HIV treatment programmes in South Africa (n = 350) were included. We investigated the association of M184V and NNRTI resistance with WHO immunological failure criteria and CD4 count trends, using chi-square tests and linear mixed models. Fewer patients with the M184V mutation reached immunologic failure criteria than those without: 51 of 151(34%) vs. 90 of 199 (45%) (P = 0.03). Similarly, 79 of 220 (36%) patients, who had major NNRTI resistance, had immunological failure, whereas 62 of 130 (48%) without (chi-square P = 0.03) did. The CD4 count decline among patients with the M184V mutation was 2.5 cells/mm(3) /year, whereas in those without M184V it was 14 cells/mm(3) /year (P = 0.1), but the difference in CD4 count decline with and without NNRTI resistance was marginal. Our data suggest that CD4 count monitoring may lead to inappropriate delayed therapy switches for patients with HIV drug resistance. Conversely, patients with viraemia but no drug resistance are more likely to have a CD4 count decline and thus may be more likely to be switched to a second-line regimen. © 2015 John Wiley & Sons Ltd.
Sun, L C; Clinton, J H; Kaplan, E; Meinhold, C B
1997-07-01
The Marshall Islands were the site of numerous tests of nuclear weapons by the United States. From 1946 to 1958, nuclear devices were detonated at Enewetak and Bikini Atolls. Following the inadvertent contamination of the northern islands downwind of the 1954 Bravo Test, Brookhaven National Laboratory became involved in the medical care and the radiological safety of the affected populations. One important technique employed in assessing the internally deposited radionuclides is whole-body counting. To estimate current and future exposures to 137Cs, data from 1989 to 1994 were analyzed and are reported in this paper. During this period, 3,618 measurements were made for the Marshallese. The cesium body contents were assumed to result from a series of chronic intakes. Also, it was assumed that cesium activity in the body reaches a plateau that is maintained over 365 d. We estimated the annual effective dose rate for each population, derived from the recommendations of the International Commission on Radiological Protection. The average 137Cs uptake measured by the whole-body counting method varies from one population to another; it was consistent with measurements of external exposure rate. The analysis, though based on limited data, indicates that there is no statistical support for a seasonal effect on 137Cs uptake. The critical population group for cesium uptake is adult males. Within the 5-y monitoring period, all internal exposures to 137Cs were less than 0.2 mSv y(-1). Similarly, a persistent average cesium effective dose rate of 2 microSv y(-1) was determined for Majuro residents.
ACR Appropriateness Criteria® growth disturbances - risk of intrauterine growth restriction.
Zelop, Carolyn M; Javitt, Marcia C; Glanc, Phyllis; Dubinsky, Theodore; Harisinghani, Mukesh G; Harris, Robert D; Khati, Nadia J; Mitchell, Donald G; Pandharipande, Pari V; Pannu, Harpreet K; Podrasky, Ann E; Shipp, Thomas D; Siegel, Cary Lynn; Simpson, Lynn; Wall, Darci J; Wong-You-Cheong, Jade J
2013-09-01
Fetal growth disturbances include fetuses at risk for intrauterine growth restriction. These fetuses may have an estimated fetal weight at less than the 10% or demonstrate a plateau of fetal growth with an estimated fetal growth greater than the 10%. Uteroplacental insufficiency may play a major role in the etiology of intrauterine growth restriction. Fetuses at risk for intrauterine fetal growth restriction are susceptible to the potential hostility of the intrauterine environment leading to fetal hypoxia and fetal acidosis. Fetal well-being can be assessed using biophysical profile, Doppler velocimetry, fetal heart rate monitoring, and fetal movement counting.Fetal growth disturbances include fetuses at risk for intrauterine growth restriction. These fetuses may have an estimated fetal weight at less than the 10% or demonstrate a plateau of fetal growth with an estimated fetal growth greater than the 10%. Uteroplacental insufficiency may play a major role in the etiology of intrauterine growth restriction. Fetuses at risk for intrauterine fetal growth restriction are susceptible to the potential hostility of the intrauterine environment leading to fetal hypoxia and fetal acidosis. Fetal well-being can be assessed using biophysical profile, Doppler velocimetry, fetal heart rate monitoring, and fetal movement counting.The ACR Appropriateness Criteria® are evidence-based guidelines for specific clinical conditions that are reviewed every two years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances where evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.
Reynolds, Michelle H.; Courtot, Karen; Hatfield, Jeffrey
2017-01-01
Wildlife managers often request a simple approach to monitor the status of species of concern. In response to that need, we used eight years of monitoring data to estimate population size and test the validity of an index for monitoring accurately the abundance of reintroduced, endangered Laysan Teal Anas laysanensis. The population was established at Midway Atoll in the Hawaiian archipelago after 42 wild birds were translocated from Laysan Island during 2004–2005. We fitted 587 birds with unique markers during 2004–2015, recorded 21,309 sightings until March 2016, and conducted standardised survey counts during 2007–2015. A modified Lincoln-Petersen mark-resight estimator and ANCOVA models were used to test the relationship between survey counts, seasonal detectability, and population abundance. Differences were found between the breeding and non-breeding seasons in detection and how maximum counts recorded related to population estimates. The results showed strong, positive correlations between the seasonal maximum counts and population estimates. The ANCOVA models supported the use of standardised bi-monthly counts of unmarked birds as a valid index to monitor trends among years within a season at Midway Atoll. The translocated population increased to 661 adult and juvenile birds (95% CI = 608–714) by 2010, then declined by 38% between 2010 and 2012 after the Toˉhoku Japan earthquake-generated tsunami inundated 41% of the atoll and triggered an Avian Botulism type C Clostridium botulinum outbreak. Following another severe botulism outbreak during 2015, the population experienced a 37% decline. Data indicated that the Midway Atoll population, like the founding Laysan Island population, is susceptible to catastrophic population declines. Consistent standardised monitoring using simple counts, in place of mark-recapture and resightings surveys, can be used to evaluate population status over the long-term. We estimate there were 314–435 Laysan Teal (95% CI for population estimate; point estimate = 375 individuals) at Midway Atoll in 2015; c. 50% of the global population. In comparison, the most recent estimate for numbers on Laysan Island was of 339 individuals in 2012 (95% CI = 265–413). We suggest that this approach can be used to validate a survey index for any marked, reintroduced resident wildlife population.
Compensated count-rate circuit for radiation survey meter
Todd, R.A.
1980-05-12
A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.
Survey of predators and sampling method comparison in sweet corn.
Musser, Fred R; Nyrop, Jan P; Shelton, Anthony M
2004-02-01
Natural predation is an important component of integrated pest management that is often overlooked because it is difficult to quantify and perceived to be unreliable. To begin incorporating natural predation into sweet corn, Zea mays L., pest management, a predator survey was conducted and then three sampling methods were compared for their ability to accurately monitor the most abundant predators. A predator survey on sweet corn foliage in New York between 1999 and 2001 identified 13 species. Orius insidiosus (Say), Coleomegilla maculata (De Geer), and Harmonia axyridis (Pallas) were the most numerous predators in all years. To determine the best method for sampling adult and immature stages of these predators, comparisons were made among nondestructive field counts, destructive counts, and yellow sticky cards. Field counts were correlated with destructive counts for all populations, but field counts of small insects were biased. Sticky cards underrepresented immature populations. Yellow sticky cards were more attractive to C. maculata adults than H. axyridis adults, especially before pollen shed, making coccinellid population estimates based on sticky cards unreliable. Field counts were the most precise method for monitoring adult and immature stages of the three major predators. Future research on predicting predation of pests in sweet corn should be based on field counts of predators because these counts are accurate, have no associated supply costs, and can be made quickly.
Use of an activity monitor to detect response to treatment in dogs with osteoarthritis.
Brown, Dorothy Cimino; Boston, Raymond C; Farrar, John T
2010-07-01
To determine whether an activity monitor (AM) could be used to detect changes in activity in dogs with osteoarthritis treated with carprofen or a placebo. Randomized controlled trial. 70 dogs with no clinically important abnormalities other than osteoarthritis for which they were not currently being treated. Dogs wore an AM continuously for 21 days. On days 8 through 21, the dogs were treated with carprofen (n = 35) or a placebo (35). Total activity counts for days 1 through 7 (baseline) were compared with total activity counts for days 15 through 21 (endpoint). The change in total activity count from baseline to endpoint was assessed within each treatment group as well as between groups. Linear regression analysis was performed to test for an association between treatment and percentage change in activity counts while controlling for other variables. For placebo-treated dogs, median baseline total activity count was not significantly different from median endpoint total activity count (1,378,408 vs 1,310,112, respectively). For dogs receiving carprofen, there was a significant increase in median activity count from baseline to endpoint (1,276,427 vs 1,374,133). When age and baseline activity counts were controlled for, dogs in the carpofen-treated group had a 20% increase in activity counts, compared with placebo-treated dogs (95% confidence interval, 10% to 26%). Results suggested that the AM used in the present study may be a valid outcome assessment tool for documenting improved activity associated with treatment in dogs with osteoarthritis.
Nowosad, Jakub; Stach, Alfred; Kasprzyk, Idalia; Weryszko-Chmielewska, Elżbieta; Piotrowska-Weryszko, Krystyna; Puc, Małgorzata; Grewling, Łukasz; Pędziszewska, Anna; Uruska, Agnieszka; Myszkowska, Dorota; Chłopek, Kazimiera; Majkowska-Wojciechowska, Barbara
The aim of the study was to create and evaluate models for predicting high levels of daily pollen concentration of Corylus , Alnus , and Betula using a spatiotemporal correlation of pollen count. For each taxon, a high pollen count level was established according to the first allergy symptoms during exposure. The dataset was divided into a training set and a test set, using a stratified random split. For each taxon and city, the model was built using a random forest method. Corylus models performed poorly. However, the study revealed the possibility of predicting with substantial accuracy the occurrence of days with high pollen concentrations of Alnus and Betula using past pollen count data from monitoring sites. These results can be used for building (1) simpler models, which require data only from aerobiological monitoring sites, and (2) combined meteorological and aerobiological models for predicting high levels of pollen concentration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alpert, B. K.; Horansky, R. D.; Bennett, D. A.
Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operationmore » at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.« less
Comparison of Point Count Sampling Regimes for Monitoring Forest Birds
William H. Buskirk; Jennifer L. McDonald
1995-01-01
A set of 255 counts was compiled for 13 points using 10-minute periods subtallied at 3 and 6 minutes. The data from each point were subsampled using combinations of count periods, numbers, and schedules to compare the effectiveness of these different regimes at per point coverage. Interspecifically, detection frequencies differed in level and pattern as a function of...
External quality assessment for CD4 + T-lymphocyte count test
Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz
2018-01-01
Abstract The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians. Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor. The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%. EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible. PMID:29794603
Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz
2018-05-01
The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians.Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor.The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%.EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible.
Dead time corrections using the backward extrapolation method
NASA Astrophysics Data System (ADS)
Gilad, E.; Dubi, C.; Geslot, B.; Blaise, P.; Kolin, A.
2017-05-01
Dead time losses in neutron detection, caused by both the detector and the electronics dead time, is a highly nonlinear effect, known to create high biasing in physical experiments as the power grows over a certain threshold, up to total saturation of the detector system. Analytic modeling of the dead time losses is a highly complicated task due to the different nature of the dead time in the different components of the monitoring system (e.g., paralyzing vs. non paralyzing), and the stochastic nature of the fission chains. In the present study, a new technique is introduced for dead time corrections on the sampled Count Per Second (CPS), based on backward extrapolation of the losses, created by increasingly growing artificially imposed dead time on the data, back to zero. The method has been implemented on actual neutron noise measurements carried out in the MINERVE zero power reactor, demonstrating high accuracy (of 1-2%) in restoring the corrected count rate.
Relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts.
Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki
2015-01-01
Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy.
Relationships among Indoor, Outdoor, and Personal Airborne Japanese Cedar Pollen Counts
Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki
2015-01-01
Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy. PMID:26110813
Muhlfeld, Clint C.; Taper, Mark L.; Staples, David F.; Shepard, Bradley B.
2006-01-01
Despite the widespread use of redd counts to monitor trends in salmonid populations, few studies have evaluated the uncertainties in observed counts. We assessed the variability in redd counts for migratory bull trout Salvelinus confluentus among experienced observers in Lion and Goat creeks, which are tributaries to the Swan River, Montana. We documented substantially lower observer variability in bull trout redd counts than did previous studies. Observer counts ranged from 78% to 107% of our best estimates of true redd numbers in Lion Creek and from 90% to 130% of our best estimates in Goat Creek. Observers made both errors of omission and errors of false identification, and we modeled this combination by use of a binomial probability of detection and a Poisson count distribution of false identifications. Redd detection probabilities were high (mean = 83%) and exhibited no significant variation among observers (SD = 8%). We applied this error structure to annual redd counts in the Swan River basin (1982–2004) to correct for observer error and thus derived more accurate estimates of redd numbers and associated confidence intervals. Our results indicate that bias in redd counts can be reduced if experienced observers are used to conduct annual redd counts. Future studies should assess both sources of observer error to increase the validity of using redd counts for inferring true redd numbers in different basins. This information will help fisheries biologists to more precisely monitor population trends, identify recovery and extinction thresholds for conservation and recovery programs, ascertain and predict how management actions influence distribution and abundance, and examine effects of recovery and restoration activities.
Nakamura, Hirotoshi; Ide, Akane; Kudo, Takumi; Nishihara, Eijun; Ito, Mitsuru; Miyauchi, Akira
2016-01-01
Objective Finding agranulocytosis (AG) at an early stage is important to improve outcome, but periodic granulocyte count monitoring is not generally recommended for patients with Graves' disease, because AG develops suddenly. Method At the Kuma Hospital, Graves' patients under antithyroid drug (ATD) treatment in an outpatient clinic have a granulocyte count examination during each visit, and if it is <1,000/μl, a warning is immediately sent to the patient's physician. We evaluated the usefulness of this system. Results We investigated 25 AG and 33 granulocytopenia (GP) cases over a recent 5-year period, excluding patients who developed AG or GP at another hospital and were referred to us for treatment. Among the 25 AG patients, 16 patients (64%; 9 asymptomatic and 7 very mild symptomatic cases) were discovered by the periodic granulocyte count examination at an outpatient clinic. The remaining 9 patients visited the Kuma Hospital or other hospitals because of infection symptoms. Most of the AG patients were given granulocyte colony-stimulating factor injections immediately and were admitted if a prompt increase in granulocytes could not be obtained. The final treatments for Graves' disease were 131I-radioisotope therapy (19 patients), thyroidectomy (2 patients), inorganic iodine (1 patient), or another ATD (1 patient). Among the 33 GP patients, 31 (94%), including 20 asymptomatic cases, were discovered during periodic granulocyte count monitoring. Most of them stopped ATD, and other treatments for Graves' disease were selected. Conclusion Periodic monitoring of granulocyte counts is useful for identifying AG and GP patients with no or minimum infection symptoms. PMID:28101490
Nakamura, Hirotoshi; Ide, Akane; Kudo, Takumi; Nishihara, Eijun; Ito, Mitsuru; Miyauchi, Akira
2016-12-01
Finding agranulocytosis (AG) at an early stage is important to improve outcome, but periodic granulocyte count monitoring is not generally recommended for patients with Graves' disease, because AG develops suddenly. At the Kuma Hospital, Graves' patients under antithyroid drug (ATD) treatment in an outpatient clinic have a granulocyte count examination during each visit, and if it is <1,000/μl, a warning is immediately sent to the patient's physician. We evaluated the usefulness of this system. We investigated 25 AG and 33 granulocytopenia (GP) cases over a recent 5-year period, excluding patients who developed AG or GP at another hospital and were referred to us for treatment. Among the 25 AG patients, 16 patients (64%; 9 asymptomatic and 7 very mild symptomatic cases) were discovered by the periodic granulocyte count examination at an outpatient clinic. The remaining 9 patients visited the Kuma Hospital or other hospitals because of infection symptoms. Most of the AG patients were given granulocyte colony-stimulating factor injections immediately and were admitted if a prompt increase in granulocytes could not be obtained. The final treatments for Graves' disease were 131 I-radioisotope therapy (19 patients), thyroidectomy (2 patients), inorganic iodine (1 patient), or another ATD (1 patient). Among the 33 GP patients, 31 (94%), including 20 asymptomatic cases, were discovered during periodic granulocyte count monitoring. Most of them stopped ATD, and other treatments for Graves' disease were selected. Periodic monitoring of granulocyte counts is useful for identifying AG and GP patients with no or minimum infection symptoms.
Mertz, Leslie
2015-01-01
It seems as if many of us are getting used to the idea of wearing sensors, whether they are counting the number of steps we take each day with an iPhone-connected pedometer or keeping track of heart rate while we are doing an exercise routine or out riding a bicycle. That's probably good preparation, because a new generation of wearable sensors and smart textiles are coming to the fore to provide extended biomedical monitoring of heart, brain, muscle, and other physiological activity.
Fast blood flow monitoring in deep tissues with real-time software correlators
Wang, Detian; Parthasarathy, Ashwin B.; Baker, Wesley B.; Gannon, Kimberly; Kavuri, Venki; Ko, Tiffany; Schenkel, Steven; Li, Zhe; Li, Zeren; Mullen, Michael T.; Detre, John A.; Yodh, Arjun G.
2016-01-01
We introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 – 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.5 cm, easily resolve pulsatile heart-beat fluctuations in blood flow which were previously considered to be noise. We employ the device to separate tissue blood flow from tissue absorption/scattering dynamics and thereby show that the origin of the pulsatile DCS signal is primarily flow, and we monitor cerebral autoregulation dynamics in healthy volunteers more accurately than with traditional instrumentation as a result of increased data acquisition rates. Finally, we characterize measurement signal-to-noise ratio and identify count rate and averaging parameters needed for optimal performance. PMID:27231588
Spectral and Timing States in Black Hole Binaries
NASA Astrophysics Data System (ADS)
Wilms, J.
Results on the long term variability of galactic black hole candidates are reviewed. I mainly present the results of a > 2 year long campaign with RXTE to monitor the canonical soft state black hole candidates LMC X-1 and LMC X-3 using monthly observations. These observations are presented within the context of the RXTE-ASM long term quasi-periodic variability on timescales of about 150d. For LMC X-3, times of low ASM count rate are correlated with a significant hardening of the X-ray spectrum. The observation with the lowest flux during the whole monitoring campaign can be modeled with a simple γ=1.7 power law -- a hard state spectrum. Since these spectral hardenings occur on the 150 d timescale it is probable that they are associated with periodic changes in the accretion rate. Possible causes for this behavior are discussed, e.g. a wind driven limit-cycle or long-term variability of the donor star.
Cryogenic, high-resolution x-ray detector with high count rate capability
Frank, Matthias; Mears, Carl A.; Labov, Simon E.; Hiller, Larry J.; Barfknecht, Andrew T.
2003-03-04
A cryogenic, high-resolution X-ray detector with high count rate capability has been invented. The new X-ray detector is based on superconducting tunnel junctions (STJs), and operates without thermal stabilization at or below 500 mK. The X-ray detector exhibits good resolution (.about.5-20 eV FWHM) for soft X-rays in the keV region, and is capable of counting at count rates of more than 20,000 counts per second (cps). Simple, FET-based charge amplifiers, current amplifiers, or conventional spectroscopy shaping amplifiers can provide the electronic readout of this X-ray detector.
Night Sky Weather Monitoring System Using Fish-Eye CCD
NASA Astrophysics Data System (ADS)
Tomida, Takayuki; Saito, Yasunori; Nakamura, Ryo; Yamazaki, Katsuya
Telescope Array (TA) is international joint experiment observing ultra-high energy cosmic rays. TA employs fluorescence detection technique to observe cosmic rays. In this technique, tho existence of cloud significantly affects quality of data. Therefore, cloud monitoring provides important information. We are developing two new methods for evaluating night sky weather with pictures taken by charge-coupled device (CCD) camera. One is evaluating the amount of cloud with pixels brightness. The other is counting the number of stars with contour detection technique. The results of these methods show clear correlation, and we concluded both the analyses are reasonable methods for weather monitoring. We discuss reliability of the star counting method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, Quan; Purdue Univ., West Lafayette, IN; Wu, Jayne
Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V.more » The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.« less
Yuan, Quan; Purdue Univ., West Lafayette, IN; Wu, Jayne; ...
2016-12-29
Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V.more » The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.« less
Considerations for monitoring raptor population trends based on counts of migrants
Titus, K.; Fuller, M.R.; Ruos, J.L.; Meyburg, B-U.; Chancellor, R.D.
1989-01-01
Various problems were identified with standardized hawk count data as annually collected at six sites. Some of the hawk lookouts increased their hours of observation from 1979-1985, thereby confounding the total counts. Data recording and missing data hamper coding of data and their use with modern analytical techniques. Coefficients of variation among years in counts averaged about 40%. The advantages and disadvantages of various analytical techniques are discussed including regression, non-parametric rank correlation trend analysis, and moving averages.
A model for predicting Xanthomonas arboricola pv. pruni growth as a function of temperature
Llorente, Isidre; Montesinos, Emilio; Moragrega, Concepció
2017-01-01
A two-step modeling approach was used for predicting the effect of temperature on the growth of Xanthomonas arboricola pv. pruni, causal agent of bacterial spot disease of stone fruit. The in vitro growth of seven strains was monitored at temperatures from 5 to 35°C with a Bioscreen C system, and a calibrating equation was generated for converting optical densities to viable counts. In primary modeling, Baranyi, Buchanan, and modified Gompertz equations were fitted to viable count growth curves over the entire temperature range. The modified Gompertz model showed the best fit to the data, and it was selected to estimate the bacterial growth parameters at each temperature. Secondary modeling of maximum specific growth rate as a function of temperature was performed by using the Ratkowsky model and its variations. The modified Ratkowsky model showed the best goodness of fit to maximum specific growth rate estimates, and it was validated successfully for the seven strains at four additional temperatures. The model generated in this work will be used for predicting temperature-based Xanthomonas arboricola pv. pruni growth rate and derived potential daily doublings, and included as the inoculum potential component of a bacterial spot of stone fruit disease forecaster. PMID:28493954
Effects of temephos (Abate? 4E) on fiddler crabs (Uca pugnax and Uca minax) on a Delaware salt marsh
Pinkney, A.E.; McGowan, P.C.; Murphy, D.R.; Lowe, T.P.; Sparling, D.W.; Meredith, W.H.
1999-01-01
The non-target effects of temephos (as Abate 4E, 44.6% active ingredient) on fiddler crabs were examined on the salt marsh at Bombay Hook National Wildlife Refuge (NWR), near Dover, DE. Six 170 x 170 m plots were established; 3 were sprayed on 4 occasions at a rate of 1.5 fl oz/acre (0.054 kg active ingredient/ha) and 3 were controls. On each plot, marsh fiddler crab (Uca pugnax) populations were monitored by repeatedly counting the number of burrow holes in 2 counting areas marked out along tidal guts. One half of each counting area was covered with bird netting to evaluate sublethal toxic effects, which, if present, could result in increased susceptibility to bird predation. A statistically significant linear association was established between the number of holes and the number of crabs. No significant differences were found in the numbers of holes (or crabs) in the sprayed vs. control plots and in the covered vs. uncovered sections. However, survival of juvenile crabs in in situ bioassays was significantly reduced (16% lower) by the spraying. Median acetylcholinesterase activity in claw muscle of red-jointed fiddler crabs (U. minax) collected 2 days after an operational spray with Abate 4E was significantly reduced (28% lower) compared to unsprayed crabs. In view of the toxicity to juvenile crabs and the cholinesterase inhibition, we recommend continued monitoring and research for non-target impacts of Abate 4E on fiddler crabs to establish whether the reported level of cholinesterase inhibition results in acute or chronic toxicity.
Swift/BAT and MAXI/GSC monitoring indicate a new outburst of black hole transient H 1743-322
NASA Astrophysics Data System (ADS)
Zhang, Hui; Yu, Wenfei; Lin, Jie; Zhang, Wenda; Yan, Zhen
2015-06-01
Swift/BAT and MAXI/GSC monitoring in the X-rays show that the black hole binary transient H 1743-322 has started a new outburst. The Swift/BAT X-ray intensity increased from 0.007+/-0.003 counts/s/cm^2 (0.029+/-0.012 Crab) on MJD 57177 to 0.024+/-0.002 counts/s/cm^2 (0.105+/-0.007 Crab) on MJD 57181 in 15-50 keV.
Harrier Information Management System (HIMS): The system and the approach
NASA Astrophysics Data System (ADS)
Reynolds, D. J.
1990-01-01
The Harrier GR5 is to be fleet-fitted with an engine monitoring system. The ground station known as HIMS was developed to enable engineers to analyze parameter exceedance and component life count data collected from it. The HIMS and its development program are reviewed. Counts can vary from aircraft to aircraft for a given number of flying hours and lifting on this basis is expected to yield considerable savings. Aspects relevant to future aircraft health monitoring programs are considered.
Antineutrino monitoring of thorium reactors
Akindele, Oluwatomi A.; Bernstein, Adam; Norman, Eric B.
2016-09-30
Various groups have demonstrated that antineutrino monitoring can be successful in assessing the plutonium content in water-cooled nuclear reactors for nonproliferation applications. New reactor designs and concepts incorporate nontraditional fuel types and chemistry. Understanding how these properties affect the antineutrino emission from a reactor can extend the applicability of antineutrino monitoring. Thorium molten salt reactors breed 233U, that if diverted constitute a direct use material as defined by the International Atomic Energy Agency (IAEA). The antineutrino spectrum from the fission of 233U has been estimated for the first time, and the feasibility of detecting the diversion of 8 kg ofmore » 233U, within a 30 day timeliness goal has been evaluated. The antineutrino emission from a thorium reactor operating under normal conditions is compared to a diversion scenario by evaluating the daily antineutrino count rate and the energy spectrum of the detected antineutrinos at a 25 m standoff. It was found that the diversion of a significant quantity of 233U could not be detected within the current IAEA timeliness detection goal using either tests. In conclusion, a rate-time based analysis exceeded the timeliness goal by 23 days, while a spectral based analysis exceeds this goal by 31 days.« less
Antineutrino monitoring of thorium reactors
NASA Astrophysics Data System (ADS)
Akindele, Oluwatomi A.; Bernstein, Adam; Norman, Eric B.
2016-09-01
Various groups have demonstrated that antineutrino monitoring can be successful in assessing the plutonium content in water-cooled nuclear reactors for nonproliferation applications. New reactor designs and concepts incorporate nontraditional fuel types and chemistry. Understanding how these properties affect the antineutrino emission from a reactor can extend the applicability of antineutrino monitoring. Thorium molten salt reactors breed 233U, that if diverted constitute a direct use material as defined by the International Atomic Energy Agency (IAEA). The antineutrino spectrum from the fission of 233U has been estimated for the first time, and the feasibility of detecting the diversion of 8 kg of 233U, within a 30 day timeliness goal has been evaluated. The antineutrino emission from a thorium reactor operating under normal conditions is compared to a diversion scenario by evaluating the daily antineutrino count rate and the energy spectrum of the detected antineutrinos at a 25 m standoff. It was found that the diversion of a significant quantity of 233U could not be detected within the current IAEA timeliness detection goal using either tests. A rate-time based analysis exceeded the timeliness goal by 23 days, while a spectral based analysis exceeds this goal by 31 days.
2015-07-17
This figure shows how the Alice instrument count rate changed over time during the sunset and sunrise observations. The count rate is largest when the line of sight to the sun is outside of the atmosphere at the start and end times. Molecular nitrogen (N2) starts absorbing sunlight in the upper reaches of Pluto's atmosphere, decreasing as the spacecraft approaches the planet's shadow. As the occultation progresses, atmospheric methane and hydrocarbons can also absorb the sunlight and further decrease the count rate. When the spacecraft is totally in Pluto's shadow the count rate goes to zero. As the spacecraft emerges from Pluto's shadow into sunrise, the process is reversed. By plotting the observed count rate in the reverse time direction, it is seen that the atmospheres on opposite sides of Pluto are nearly identical. http://photojournal.jpl.nasa.gov/catalog/PIA19716
Measuring the Galactic Cosmic Ray flux with the LISA Pathfinder radiation monitor
NASA Astrophysics Data System (ADS)
Armano, M.; Audley, H.; Baird, J.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Castelli, E.; Cavalleri, A.; Cesarini, A.; Cruise, A. M.; Danzmann, K.; de Deus Silva, M.; Diepholz, I.; Dixon, G.; Dolesi, R.; Ferraioli, L.; Ferroni, V.; Finetti, N.; Fitzsimons, E. D.; Freschi, M.; Gesa, L.; Gibert, F.; Giardini, D.; Giusteri, R.; Grimani, C.; Grzymisch, J.; Harrison, I.; Heinzel, G.; Hewitson, M.; Hollington, D.; Hoyland, D.; Hueller, M.; Inchauspé, H.; Jennrich, O.; Jetzer, P.; Karnesis, N.; Kaune, B.; Korsakova, N.; Killow, C. J.; Lobo, J. A.; Lloro, I.; Liu, L.; Lopez-Zaragoza, J. P.; Maarschalkerweerd, R.; Mance, D.; Meshskar, N.; Martín, V.; Martin-Polo, L.; Martino, J.; Martin-Porqueras, F.; Mateos, I.; McNamara, P. W.; Mendes, J.; Mendes, L.; Nofrarias, M.; Paczkowski, S.; Perreur-Lloyd, M.; Petiteau, A.; Pivato, P.; Plagnol, E.; Ramos-Castro, J.; Reiche, J.; Robertson, D. I.; Rivas, F.; Russano, G.; Slutsky, J.; Sopuerta, C. F.; Sumner, T.; Texier, D.; Thorpe, J. I.; Vetrugno, D.; Vitale, S.; Wanner, G.; Ward, H.; Wass, P.; Weber, W. J.; Wissel, L.; Wittchen, A.; Zweifel, P.
2018-03-01
Test mass charging caused by cosmic rays will be a significant source of acceleration noise for space-based gravitational wave detectors like LISA. Operating between December 2015 and July 2017, the technology demonstration mission LISA Pathfinder included a bespoke monitor to help characterise the relationship between test mass charging and the local radiation environment. The radiation monitor made in situ measurements of the cosmic ray flux while also providing information about its energy spectrum. We describe the monitor and present measurements which show a gradual 40% increase in count rate coinciding with the declining phase of the solar cycle. Modulations of up to 10% were also observed with periods of 13 and 26 days that are associated with co-rotating interaction regions and heliospheric current sheet crossings. These variations in the flux above the monitor detection threshold ( ≈ 70 MeV) are shown to be coherent with measurements made by the IREM monitor on-board the Earth orbiting INTEGRAL spacecraft. Finally we use the measured deposited energy spectra, in combination with a GEANT4 model, to estimate the galactic cosmic ray differential energy spectrum over the course of the mission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sacchi, R; Guarachi, L Fanola; Monaco, V
2015-06-15
Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energymore » and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.« less
Nichols, J.D.; Sauer, J.R.; Hines, J.E.; Boulinier, T.; Pollock, K.H.; Therres, Glenn D.
2001-01-01
Although many ecological monitoring programs are now in place, the use of resulting data to draw inferences about changes in biodiversity is problematic. The difficulty arises because of the inability to count all animals present in any sampled area. This inability results not only in underestimation of species richness but also in potentially misleading comparisons of species richness over time and space. We recommend the use of probabilistic estimators for estimating species richness and related parameters (e.g., rate of change in species richness, local extinction probability, local turnover, local colonization) when animal detection probabilities are <1. We illustrate these methods using data from the North American Breeding Bird Survey obtained along survey routes in Maryland. We also introduce software to implement these estimation methods.
Monitoring Physiological Changes in Haloarchaeal Cell during Virus Release
Svirskaitė, Julija; Oksanen, Hanna M.; Daugelavičius, Rimantas; Bamford, Dennis H.
2016-01-01
The slow rate of adsorption and non-synchronous release of some archaeal viruses have hindered more thorough analyses of the mechanisms of archaeal virus release. To address this deficit, we utilized four viruses that infect Haloarcula hispanica that represent the four virion morphotypes currently known for halophilic euryarchaeal viruses: (1) icosahedral internal membrane-containing SH1; (2) icosahedral tailed HHTV-1; (3) spindle-shaped His1; and (4) pleomorphic His2. To discern the events occurring as the progeny viruses exit, we monitored culture turbidity, as well as viable cell and progeny virus counts of infected and uninfected cultures. In addition to these traditional metrics, we measured three parameters associated with membrane integrity: the binding of the lipophilic anion phenyldicarbaundecaborane, oxygen consumption, and both intra- and extra-cellular ATP levels. PMID:26927156
Miller, M.W.; Greenstone, E.M.; Greenstone, W.; Bildstein, K.L.
2002-01-01
The Broad-winged Hawk (Buteo platypterus) breeds in eastern and central Canada and the United States, and winters in Central America and northern and central South America. Birders and ornithologists count migrating Broad-winged Hawks at dozens of traditional watch sites throughout the northeastern United States. We modeled counts of migrating Broad-winged Hawks from two raptor migration watch sites: Montclair Hawk Lookout, New Jersey, and Hawk Mountain Sanctuary, Pennsylvania, to determine whether annual abundance and trend estimates from individual sites within the mid-Atlantic states are representative of the region as a whole. We restricted ourselves to counts made between 10:00 and 16:00 EST during September to standardize count effort between sites. We created one model set for annual counts and another model set for daily counts. When modeling daily counts we incorporated weather and identity of individual observers. Akaike's Information Criteria were used to select the best model from an initial set of competing models. Annual counts declined at both sites during 1979-1998. Broad-winged Hawk migration began, peaked, and ended later at Montclair than at Hawk Mountain, even though Hawk Mountain is 155 km west-southwest of Montclair. Mean annual counts of hawks at Montclair were more than twice those at Hawk Mountain, but were not correlated. Broad-winged Hawks counted at Montclair may not be the same birds as those counted at Hawk Mountain. Rather, the two sites may be monitoring different regional subpopulations. Broad-winged Hawks counted at the two sites may use different migration tactics, with those counted at Hawk Mountain being more likely to slope soar, and those at Montclair more likely to use thermal soaring. A system of multiple watch sites is needed to monitor various breeding populations of this widely dispersed migrant.
Elders Point East Marsh Island Restoration Monitoring Data Analysis
2017-09-21
Figure 13. Average biomass comparison between fertilizer treatment and non- fertilizer treatment at Elders East...25 ERDC/EL CR-17-1 vi Table 5. Count of benthic organisms ...31 Table 6. Benthic Community Indices: True Taxa Richness, Total Organism Count
Kurz, Christopher; Bauer, Julia; Conti, Maurizio; Guérin, Laura; Eriksson, Lars; Parodi, Katia
2015-07-01
External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β(+)-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80,000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% - 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.
Use of an activity monitor to detect response to treatment in dogs with osteoarthritis
Brown, Dorothy Cimino; Boston, Raymond C.; Farrar, John T.
2010-01-01
Objective To determine whether an activity monitor (AM) could be used to detect changes in activity in dogs with osteoarthritis treated with carprofen or a placebo. Design Randomized controlled trial. Animals 70 dogs with no clinically important abnormalities other than osteoarthritis for which they were not currently being treated. Procedures Dogs wore an AM continuously for 21 days. On days 8 through 21, the dogs were treated with carprofen (n = 35) or a placebo (35). Total activity counts for days 1 through 7 (baseline) were compared with total activity counts for days 15 through 21 (endpoint). The change in total activity count from baseline to endpoint was assessed within each treatment group as well as between groups. Linear regression analysis was performed to test for an association between treatment and percentage change in activity counts while controlling for other variables. Results For placebo-treated dogs, median baseline total activity count was not significantly different from median endpoint total activity count (1,378,408 vs 1,310,112, respectively). For dogs receiving carprofen, there was a significant increase in median activity count from baseline to endpoint (1,276,427 vs 1,374,133). When age and baseline activity counts were controlled for, dogs in the carpofen-treated group had a 20% increase in activity counts, compared with placebo-treated dogs (95% confidence interval, 10% to 26%). Conclusions and Clinical Relevance Results suggested that the AM used in the present study may be a valid outcome assessment tool for documenting improved activity associated with treatment in dogs with osteoarthritis. PMID:20590496
Kids Count in Indiana: 1996 Data Book.
ERIC Educational Resources Information Center
Erickson, Judith B.
This Kids Count report is the third in a series examining statewide trends in the well-being of Indiana's children. The report combines statistics of special concern in Indiana with 10 national Kids Count well-being indicators: (1) percent low birthweight; (2) infant mortality rate; (3) child death rate; (4) birth rate to unmarried teens ages 15…
Activity patterns and monitoring numbers of Horned Puffins and Parakeet Auklets
Hatch, Shyla A.
2002-01-01
Nearshore counts of birds on the water and time-lapse photography were used to monitor seasonal activity patterns and interannual variation in numbers of Horned Puffins (Fratercula corniculata) and Parakeet Auklets (Aethia psittacula) at the Semidi Islands, Alaska. The best period for over-water counts was mid egg-laying through hatching in auklets and late prelaying through early hatching in puffins. Daily counts (07.00 h-09.30 h) varied widely, with peak numbers and days with few or no birds present occurring throughout the census period. Variation among annual means in four years amounted to 26% and 72% of total count variation in puffins and auklets, respectively. Time-lapse photography of nesting habitat in early incubation revealed a morning (08.00 h-12.00 h) peak in the number of puffins loitering on study plots. Birds recorded in time-lapse images never comprised more than a third of the estimated breeding population on a plot. Components of variance in the time-lapse study were 29% within hours, 9% among hours (08.00 h-12.00 h), and 62% among days (8-29 June). Variability of overwater and land-based counts is reduced by standardizing the time of day when counts are made, but weather conditions had little influence on either type of count. High international variation of population indices implies low power to detect numerical trends in crevice-nesting auklets and puffins.
Dunn, Michael J; Jackson, Jennifer A; Adlard, Stacey; Lynnes, Amanda S; Briggs, Dirk R; Fox, Derren; Waluda, Claire M
2016-01-01
We report long-term changes in population size of three species of sympatrically breeding pygoscelid penguins: Adélie (Pygoscelis adeliae), chinstrap (Pygoscelis antarctica) and gentoo (Pygoscelis papua ellsworthii) over a 38 year period at Signy Island, South Orkney Islands, based on annual counts from selected colonies and decadal all-island systematic counts of occupied nests. Comparing total numbers of breeding pairs over the whole island from 1978/79 to 2015/16 revealed varying fortunes: gentoo penguin pairs increased by 255%, (3.5% per annum), chinstrap penguins declined by 68% (-3.6% per annum) and Adélie penguins declined by 42% (-1.5% per annum). The chinstrap population has declined steadily over the last four decades. In contrast, Adélie and gentoo penguins have experienced phases of population increase and decline. Annual surveys of selected chinstrap and Adélie colonies produced similar trends from those revealed by island-wide surveys, allowing total island population trends to be inferred relatively well. However, while the annual colony counts of chinstrap and Adélie penguins showed a trend consistent in direction with the results from all-island surveys, the magnitude of estimated population change was markedly different between colony wide and all island counts. Annual population patterns suggest that pair numbers in the study areas partly reflect immigration and emigration of nesting birds between different parts of the island. Breeding success for all three species remained broadly stable over time in the annually monitored colonies. Breeding success rates in gentoo and chinstrap penguins were strongly correlated, despite the differing trends in population size. This study shows the importance of effective, standardised monitoring to accurately determine long-term population trajectories. Our results indicate significant declines in the Adélie and chinstrap penguin populations at Signy Island over the last five decades, and a gradual increase in gentoo breeding pairs.
Dunn, Michael J.; Jackson, Jennifer A.; Adlard, Stacey; Lynnes, Amanda S.; Briggs, Dirk R.; Fox, Derren; Waluda, Claire M.
2016-01-01
We report long-term changes in population size of three species of sympatrically breeding pygoscelid penguins: Adélie (Pygoscelis adeliae), chinstrap (Pygoscelis antarctica) and gentoo (Pygoscelis papua ellsworthii) over a 38 year period at Signy Island, South Orkney Islands, based on annual counts from selected colonies and decadal all-island systematic counts of occupied nests. Comparing total numbers of breeding pairs over the whole island from 1978/79 to 2015/16 revealed varying fortunes: gentoo penguin pairs increased by 255%, (3.5% per annum), chinstrap penguins declined by 68% (-3.6% per annum) and Adélie penguins declined by 42% (-1.5% per annum). The chinstrap population has declined steadily over the last four decades. In contrast, Adélie and gentoo penguins have experienced phases of population increase and decline. Annual surveys of selected chinstrap and Adélie colonies produced similar trends from those revealed by island-wide surveys, allowing total island population trends to be inferred relatively well. However, while the annual colony counts of chinstrap and Adélie penguins showed a trend consistent in direction with the results from all-island surveys, the magnitude of estimated population change was markedly different between colony wide and all island counts. Annual population patterns suggest that pair numbers in the study areas partly reflect immigration and emigration of nesting birds between different parts of the island. Breeding success for all three species remained broadly stable over time in the annually monitored colonies. Breeding success rates in gentoo and chinstrap penguins were strongly correlated, despite the differing trends in population size. This study shows the importance of effective, standardised monitoring to accurately determine long-term population trajectories. Our results indicate significant declines in the Adélie and chinstrap penguin populations at Signy Island over the last five decades, and a gradual increase in gentoo breeding pairs. PMID:27783668
Design Study of an Incinerator Ash Conveyor Counting System - 13323
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaederstroem, Henrik; Bronson, Frazier
A design study has been performed for a system that should measure the Cs-137 activity in ash from an incinerator. Radioactive ash, expected to consist of both Cs-134 and Cs-137, will be transported on a conveyor belt at 0.1 m/s. The objective of the counting system is to determine the Cs-137 activity and direct the ash to the correct stream after a diverter. The decision levels are ranging from 8000 to 400000 Bq/kg and the decision error should be as low as possible. The decision error depends on the total measurement uncertainty which depends on the counting statistics and themore » uncertainty in the efficiency of the geometry. For the low activity decision it is necessary to know the efficiency to be able to determine if the signal from the Cs-137 is above the minimum detectable activity and that it generates enough counts to reach the desired precision. For the higher activity decision the uncertainty of the efficiency needs to be understood to minimize decision errors. The total efficiency of the detector is needed to be able to determine if the detector will be able operate at the count rate at the highest expected activity. The design study that is presented in this paper describes how the objectives of the monitoring systems were obtained, the choice of detector was made and how ISOCS (In Situ Object Counting System) mathematical modeling was used to calculate the efficiency. The ISOCS uncertainty estimator (IUE) was used to determine which parameters of the ash was important to know accurately in order to minimize the uncertainty of the efficiency. The examined parameters include the height of the ash on the conveyor belt, the matrix composition and density and relative efficiency of the detector. (authors)« less
Lee, Joey A; Williams, Skip M; Brown, Dale D; Laurson, Kelly R
2015-01-01
Activity monitors are frequently used to assess activity in many settings. But as technology advances, so do the mechanisms used to estimate activity causing a continuous need to validate newly developed monitors. The purpose of this study was to examine the step count validity of the Yamax Digiwalker SW-701 pedometer (YX), Omron HJ-720 T pedometer (OP), Polar Active accelerometer (PAC) and Actigraph gt3x+ accelerometer (AG) under controlled and free-living conditions. Participants completed five stages of treadmill walking (n = 43) and a subset of these completed a 3-day free-living wear period (n = 37). Manually counted (MC) steps provided a criterion measure for treadmill walking, whereas the comparative measure during free-living was the YX. During treadmill walking, the OP was the most accurate monitor across all speeds (±1.1% of MC steps), while the PAC underestimated steps by 6.7-16.0% per stage. During free-living, the OP and AG counted 97.5% and 98.5% of YX steps, respectively. The PAC overestimated steps by 44.0%, or 5,265 steps per day. The Omron pedometer seems to provide the most reliable and valid estimate of steps taken, as it was the best performer under lab-based conditions and provided comparable results to the YX in free-living. Future studies should consider these monitors in additional populations and settings.
RAVAL, JAY S.; KOCH, EILEEN; DONNENBERG, ALBERT D.
2014-01-01
Background aims Airborne particulate monitoring is mandated as a component of good manufacturing practice. We present a procedure developed to monitor and interpret airborne particulates in an International Organization for Standardization (ISO) class 7 cleanroom used for the cell processing of Section 351 and Section 361 products. Methods We collected paired viable and non-viable airborne particle data over a period of 1 year in locations chosen to provide a range of air quality. We used receiver operator characteristic (ROC) analysis to determine empirically the relationship between non-viable and viable airborne particle counts. Results Viable and non-viable particles were well-correlated (r 2 = 0.78), with outlier observations at the low end of the scale (non-viable particles without detectable airborne colonies). ROC analysis predicted viable counts ≥0.5/feet 3 (a limit set by the United States Pharmacopeia) at an action limit of ≥32 000 particles (≥0.5 μ)/feet 3 , with 95.6% sensitivity and 50% specificity. This limit was exceeded 2.6 times during 18 months of retrospective daily cleanroom data (an expected false alarm rate of 1.3 times/year). After implementing this action limit, we were alerted in real time to an air-handling failure undetected by our hospital facilities management. Conclusions A rational action limit for non-viable particles was determined based on the correlation with airborne colonies. Reaching or exceeding the action limit of 32 000 non-viable particles/feet 3 triggers suspension of cleanroom cell-processing activities, deep cleaning, investigation of air handling, and a deviation management process. Our full procedure for particle monitoring is available as an online supplement. PMID:22746538
Raval, Jay S; Koch, Eileen; Donnenberg, Albert D
2012-10-01
Airborne particulate monitoring is mandated as a component of good manufacturing practice. We present a procedure developed to monitor and interpret airborne particulates in an International Organization for Standardization (ISO) class 7 cleanroom used for the cell processing of Section 351 and Section 361 products. We collected paired viable and non-viable airborne particle data over a period of 1 year in locations chosen to provide a range of air quality. We used receiver operator characteristic (ROC) analysis to determine empirically the relationship between non-viable and viable airborne particle counts. Viable and non-viable particles were well-correlated (r(2) = 0.78), with outlier observations at the low end of the scale (non-viable particles without detectable airborne colonies). ROC analysis predicted viable counts ≥ 0.5/feet(3) (a limit set by the United States Pharmacopeia) at an action limit of ≥ 32 000 particles (≥ 0.5 µ)/feet(3), with 95.6% sensitivity and 50% specificity. This limit was exceeded 2.6 times during 18 months of retrospective daily cleanroom data (an expected false alarm rate of 1.3 times/year). After implementing this action limit, we were alerted in real time to an air-handling failure undetected by our hospital facilities management. A rational action limit for non-viable particles was determined based on the correlation with airborne colonies. Reaching or exceeding the action limit of 32 000 non-viable particles/feet(3) triggers suspension of cleanroom cell-processing activities, deep cleaning, investigation of air handling, and a deviation management process. Our full procedure for particle monitoring is available as an online supplement.
X-ray spectrometer with a low-cost SiC photodiode
NASA Astrophysics Data System (ADS)
Zhao, S.; Lioliou, G.; Barnett, A. M.
2018-04-01
A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines which were used to characterise the instrument. The energy resolution (full width at half maximum, FWHM) of the spectrometer was found to be 1.6 keV to 1.8 keV, across the energy range. The energy linearity of the detector/spectrometer (i.e. the detector's charge output per photon as a function of incident photon energy across the 4.95 keV to 21.17 keV energy range), as well as the count rate linearity of the detector/spectrometer (i.e. number of detected photons as a function of photon fluence at a specific energy) were investigated. The energy linearity of the detector/spectrometer was linear with an error < ± 0.7 %; the count rate linearity of the detector/spectrometer was linear with an error < ± 2 %. The use of COTS SiC photodiodes as detectors for X-ray spectrometers is attractive for nanosatellite/CubeSat applications (including solar flare monitoring), and for cost sensitive industrial uses.
Population size and winter distribution of eastern American oystercatchers
Brown, S.C.; Schulte, Shiloh A.; Harrington, B.; Winn, Brad; Bart, J.; Howe, M.
2005-01-01
Conservation of the eastern subspecies of the American oystercatcher (Haematopus palliatus palliatus) is a high priority in the U.S. Shorebird Conservation Plan, but previous population estimates were unreliable, information on distribution and habitat associations during winter was incomplete, and methods for long-term monitoring had not been developed prior to this survey. We completed the aerial survey proposed in the U.S. Shorebird Conservation Plan to determine population size, winter distribution, and habitat associations. We conducted coastal aerial surveys from New Jersey to Texas during November 2002 to February 2003. This area comprised the entire wintering range of the eastern American oystercatcher within the United States. Surveys covered all suitable habitat in the United States for the subspecies, partitioned into 3 survey strata: known roost sites, high-use habitat, and inter-coastal tidal habitat. We determined known roost sites from extensive consultation with biologists and local experts in each state. High-use habitat included sand islands, sand spits at inlets, shell rakes, and oyster reefs. Partner organizations conducted ground counts in most states. We used high resolution still photography to determine detection rates for estimates of the number of birds in particular flocks, and we used ground counts to determine detection rates of flocks. Using a combination of ground and aerial counts, we estimated the population of eastern American oystercatchers to be 10,971 +/- 298. Aerial surveys can serve an important management function for shorebirds and possibly other coastal waterbirds by providing population status and trend information across a wide geographic scale.
NASA Astrophysics Data System (ADS)
Mangeard, Pierre-Simon; Clem, John; Evenson, Paul; Pyle, Roger; Mitthumsiri, Warit; Ruffolo, David; Sáiz, Alejandro; Nutaro, Tanin
2018-05-01
Solar modulation refers to Galactic cosmic-ray variations with the ∼11 yr sunspot cycle and ∼22 yr solar magnetic cycle and is relevant to the space radiation environment and effects on Earth’s atmosphere. Its complicated dependence on solar and heliospheric conditions is only roughly understood and has been empirically modeled in terms of a single modulation parameter. Most analyses of solar modulation use neutron monitor (NM) data from locations with relatively low geomagnetic cutoff rigidity, i.e., the threshold for cosmic rays to penetrate Earth’s magnetic field. The Princess Sirindhorn Neutron Monitor at Doi Inthanon, Thailand, has the world’s highest cutoff rigidity (≈17 GV) where observations span a complete solar modulation cycle (since late 2007). The pattern of solar modulation at Doi Inthanon during 2011–2014 was qualitatively very different from that at a low geomagnetic cutoff and is not well described by the same modulation parameter. At other times, NM count rates from Doi Inthanon and McMurdo, Antarctica (cutoff ∼1 GV), were linearly correlated and confirm the observation from latitude surveys in the previous solar cycle that the slope of the correlation changes with solar magnetic polarity. Low solar magnetic tilt angles (<40° at negative polarity) were well correlated with variations at both NM stations, as predicted by drift models. At a higher tilt angle, the Doi Inthanon count rate is well correlated with the interplanetary magnetic field, which is consistent with an increase in diffusion at high rigidity short-circuiting the effects of drifts and the heliospheric current sheet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bieber, J. W.; Clem, J.; Evenson, P.
A ground level enhancement (GLE) is a solar event that accelerates ions (mostly protons) to GeV range energies in such great numbers that ground-based detectors, such as neutron monitors, observe their showers in Earth's atmosphere above the Galactic cosmic ray background. GLEs are of practical interest because an enhanced relativistic ion flux poses a hazard to astronauts, air crews, and aircraft electronics, and provides the earliest direct indication of an impending space radiation storm. The giant GLE of 2005 January 20 was the second largest on record (and largest since 1956), with up to 4200% count rate enhancement at seamore » level. We analyzed data from the Spaceship Earth network, supplemented to comprise 13 polar neutron monitor stations with distinct asymptotic viewing directions and Polar Bare neutron counters at South Pole, to determine the time evolution of the relativistic proton density, energy spectrum, and three-dimensional directional distribution. We identify two energy-dispersive peaks, indicating two solar injections. The relativistic solar protons were initially strongly beamed, with a peak maximum-to-minimum anisotropy ratio over 1000:1. The directional distribution is characterized by an axis of symmetry, determined independently for each minute of data, whose angle from the magnetic field slowly varied from about 60 Degree-Sign to low values and then rose to about 90 Degree-Sign . The extremely high relativistic proton flux from certain directions allowed 10 s tracking of count rates, revealing fluctuations of period {approx}> 2 minutes with up to 50% fractional changes, which we attribute to fluctuations in the axis of symmetry.« less
Real-time people counting system using a single video camera
NASA Astrophysics Data System (ADS)
Lefloch, Damien; Cheikh, Faouzi A.; Hardeberg, Jon Y.; Gouton, Pierre; Picot-Clemente, Romain
2008-02-01
There is growing interest in video-based solutions for people monitoring and counting in business and security applications. Compared to classic sensor-based solutions the video-based ones allow for more versatile functionalities, improved performance with lower costs. In this paper, we propose a real-time system for people counting based on single low-end non-calibrated video camera. The two main challenges addressed in this paper are: robust estimation of the scene background and the number of real persons in merge-split scenarios. The latter is likely to occur whenever multiple persons move closely, e.g. in shopping centers. Several persons may be considered to be a single person by automatic segmentation algorithms, due to occlusions or shadows, leading to under-counting. Therefore, to account for noises, illumination and static objects changes, a background substraction is performed using an adaptive background model (updated over time based on motion information) and automatic thresholding. Furthermore, post-processing of the segmentation results is performed, in the HSV color space, to remove shadows. Moving objects are tracked using an adaptive Kalman filter, allowing a robust estimation of the objects future positions even under heavy occlusion. The system is implemented in Matlab, and gives encouraging results even at high frame rates. Experimental results obtained based on the PETS2006 datasets are presented at the end of the paper.
Invariance of wearing location of Omron-BI pedometers: a validation study.
Zhu, Weimo; Lee, Miyoung
2010-11-01
The purpose of this study was to investigate the validity and reliability evidences of the Omron BI pedometer, which could count steps taken even when worn at different locations on the body. Forty (20 males and 20 females) adults were recruited to walk wearing 5 sets, 1 set at a time, of 10 BI pedometers during testing, 1 each at 10 different locations. For comparison, they also wore 2 Yamax Digi-Walker SW-200 pedometers and a Dynastream AMP 331 activity monitor. The subjects walked in 3 free-living conditions: a flat sidewalk, stairs, and mixed conditions. Except for a slight decrease in accuracy in the pant pocket locations, Omron BI pedometers counted steps accurately across other locations when subjects walked on the flat sidewalk, and the performance was consistent across devices and trials. When the subjects climbed up stairs, however, the absolute error % of the pant pocket locations increased significantly (P < .05) and similar or higher error rates were found in the AMP 331 and SW-200s. The Omron BI pedometer can accurately count steps when worn at various locations on the body in free-living conditions except for front pant pocket locations, especially when climbing stairs.
Evaluation of seven aquatic sampling methods for amphibians and other aquatic fauna
Gunzburger, M.S.
2007-01-01
To design effective and efficient research and monitoring programs researchers must have a thorough understanding of the capabilities and limitations of their sampling methods. Few direct comparative studies exist for aquatic sampling methods for amphibians. The objective of this study was to simultaneously employ seven aquatic sampling methods in 10 wetlands to compare amphibian species richness and number of individuals detected with each method. Four sampling methods allowed counts of individuals (metal dipnet, D-frame dipnet, box trap, crayfish trap), whereas the other three methods allowed detection of species (visual encounter, aural, and froglogger). Amphibian species richness was greatest with froglogger, box trap, and aural samples. For anuran species, the sampling methods by which each life stage was detected was related to relative length of larval and breeding periods and tadpole size. Detection probability of amphibians varied across sampling methods. Box trap sampling resulted in the most precise amphibian count, but the precision of all four count-based methods was low (coefficient of variation > 145 for all methods). The efficacy of the four count sampling methods at sampling fish and aquatic invertebrates was also analyzed because these predatory taxa are known to be important predictors of amphibian habitat distribution. Species richness and counts were similar for fish with the four methods, whereas invertebrate species richness and counts were greatest in box traps. An effective wetland amphibian monitoring program in the southeastern United States should include multiple sampling methods to obtain the most accurate assessment of species community composition at each site. The combined use of frogloggers, crayfish traps, and dipnets may be the most efficient and effective amphibian monitoring protocol. ?? 2007 Brill Academic Publishers.
Caffrey, J A; Higley, K A; Farsoni, A T; Smith, S; Menn, S
2012-09-01
A custom radiation monitoring system was developed by Oregon State University at the request of the Woods Hole Oceanographic Institute to measure radioactive cesium contaminants in the ocean waters near Fukushima Dai-ichi Nuclear Power Plant. The system was to be used on board the R/V Ka'imikai-O-Kanaloa during a 15 d research cruise to provide real-time approximations of radionuclide concentration and alert researchers to the possible occurrence of highly elevated radionuclide concentrations. A NaI(Tl) scintillation detector was coupled to a custom-built compact digital spectroscopy system and suspended within a sealed tank of continuously flowing seawater. A series of counts were acquired within an energy region corresponding to the main photopeak of (137)Cs. The system was calibrated using known quantities of radioactive (134)Cs and (137)Cs in a ratio equating to that present at the reactors' ocean outlet. The response between net count rate and concentration of (137)Cs was then used to generate temporal and geographic plots of (137)Cs concentration throughout the research cruise in Japanese coastal waters. The concentration of (137)Cs was low but detectable, reaching a peak of 3.8 ± 0.2 Bq/L. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Schaefer, R. K.; Wolven, B. C.; Paxton, L.; Romeo, G.; Selby, C.; Hsieh, S. W.
2013-12-01
The South Atlantic Anomaly (SAA) is a region where the Earth's inner radiation belt dips down and bathes low earth orbit satellites with energetic charged particles sometimes causing problems for satellite operations. We will describe data from a series of UV spectrographic imagers (DMSP/SSUSI) that remain on through 4 daily SAA passages. Using spectrographic information, we are able to separate, study, and remove the detector counts due to energetic (~ 1 MeV and above) particle hits. We have made a model of the SAA at Defense Meteorological Satellite Program altitudes (~850 km), and we are able to monitor the intensity of the SAA over the long term (> a decade). Using this window into the inner radiation belt, we are able to see seasonal and solar cycle variations in intensity. In this talk we will describe the techniques, the model, and show results of our study, and and indicate directions for future development and usefulness of using SSUSI as an inner radiation belt particle intensity monitor. Nighttime 427 nm Photometer count rates as seen by SSUSI binned onto a 3 x 3 degree grid and accumulated over the year 2006. The classic shape of the South Atlantic Anomaly is clearly traced by the data.
Biofilm responses to ageing and to a high phosphate load in a bench-scale drinking water system.
Batté, Magali; Koudjonou, Boniface; Laurent, Patrick; Mathieu, Laurence; Coallier, Josée; Prévost, Michèle
2003-03-01
The effects of ageing and of phosphate load on drinking water biofilms developed on a polycarbonate substratum in the pseudo-equilibrium state have been evaluated. Phosphate was added in an amount higher than the stochiometric nutrient requirements of bacteria, at concentrations commonly applied in a drinking water distribution system for corrosion control. Multiple parameters were monitored: heterotrophic plate counts (HPCs), total direct counts (TDCs) and potential exoproteolytic activity (PEPA) in order to characterise changes in bacterial biofilms. The total carbohydrate, amino acid and phosphate contents of biofilms were analysed to characterise and monitor the biochemical composition of the biofilm.The three enumeration methods showed that a pseudo-equilibrium state was reached after 7 weeks of colonisation after which, the bacterial growth rate in the biofilm was 0.1 log per week on average. Bulk phosphate addition doubled the phosphate in the biofilm, but did not affect the other biological, physiological or chemical parameters measured. Polysaccharides increased in the biofilm with ageing and the dynamics of individual carbohydrate synthesis also varied with the age of the biofilm. Once pseudo-equilibrium, it was found that the total proteins were globally constant, whereas the spectra of some individual amino acids of the proteins had significantly changed.
Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.
Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min
2018-03-01
High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.
Bayesian analyses of time-interval data for environmental radiation monitoring.
Luo, Peng; Sharp, Julia L; DeVol, Timothy A
2013-01-01
Time-interval (time difference between two consecutive pulses) analysis based on the principles of Bayesian inference was investigated for online radiation monitoring. Using experimental and simulated data, Bayesian analysis of time-interval data [Bayesian (ti)] was compared with Bayesian and a conventional frequentist analysis of counts in a fixed count time [Bayesian (cnt) and single interval test (SIT), respectively]. The performances of the three methods were compared in terms of average run length (ARL) and detection probability for several simulated detection scenarios. Experimental data were acquired with a DGF-4C system in list mode. Simulated data were obtained using Monte Carlo techniques to obtain a random sampling of the Poisson distribution. All statistical algorithms were developed using the R Project for statistical computing. Bayesian analysis of time-interval information provided a similar detection probability as Bayesian analysis of count information, but the authors were able to make a decision with fewer pulses at relatively higher radiation levels. In addition, for the cases with very short presence of the source (< count time), time-interval information is more sensitive to detect a change than count information since the source data is averaged by the background data over the entire count time. The relationships of the source time, change points, and modifications to the Bayesian approach for increasing detection probability are presented.
Using citizen science butterfly counts to predict species population trends.
Dennis, Emily B; Morgan, Byron J T; Brereton, Tom M; Roy, David B; Fox, Richard
2017-12-01
Citizen scientists are increasingly engaged in gathering biodiversity information, but trade-offs are often required between public engagement goals and reliable data collection. We compared population estimates for 18 widespread butterfly species derived from the first 4 years (2011-2014) of a short-duration citizen science project (Big Butterfly Count [BBC]) with those from long-running, standardized monitoring data collected by experienced observers (U.K. Butterfly Monitoring Scheme [UKBMS]). BBC data are gathered during an annual 3-week period, whereas UKBMS sampling takes place over 6 months each year. An initial comparison with UKBMS data restricted to the 3-week BBC period revealed that species population changes were significantly correlated between the 2 sources. The short-duration sampling season rendered BBC counts susceptible to bias caused by interannual phenological variation in the timing of species' flight periods. The BBC counts were positively related to butterfly phenology and sampling effort. Annual estimates of species abundance and population trends predicted from models including BBC data and weather covariates as a proxy for phenology correlated significantly with those derived from UKBMS data. Overall, citizen science data obtained using a simple sampling protocol produced comparable estimates of butterfly species abundance to data collected through standardized monitoring methods. Although caution is urged in extrapolating from this U.K. study of a small number of common, conspicuous insects, we found that mass-participation citizen science can simultaneously contribute to public engagement and biodiversity monitoring. Mass-participation citizen science is not an adequate replacement for standardized biodiversity monitoring but may extend and complement it (e.g., through sampling different land-use types), as well as serving to reconnect an increasingly urban human population with nature. © 2017 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G.; Salapura, Valentina
2012-07-24
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.
Sawchuk, Craig N; Russo, Joan E; Charles, Steve; Goldberg, Jack; Forquera, Ralph; Roy-Byrne, Peter; Buchwald, Dedra
2011-01-01
We examined if step-count goal setting resulted in increases in physical activity and walking compared to only monitoring step counts with pedometers among American Indian/Alaska Native elders. Outcomes included step counts, self-reported physical activity and well-being, and performance on the 6-minute walk test. Although no significant between-group differences were found, within-group analyses indicated that elders significantly improved on the majority of step count, physical activity, health-related quality of life, and 6-minute walk outcomes.
Li, Gang; Xu, Jiayun; Zhang, Jie
2015-01-01
Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am-Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am-Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. Copyright © 2014 Elsevier Ltd. All rights reserved.
A cylindrical SPECT camera with de-centralized readout scheme
NASA Astrophysics Data System (ADS)
Habte, F.; Stenström, P.; Rillbert, A.; Bousselham, A.; Bohm, C.; Larsson, S. A.
2001-09-01
An optimized brain single photon emission computed tomograph (SPECT) camera is being designed at Stockholm University and Karolinska Hospital. The design goal is to achieve high sensitivity, high-count rate and high spatial resolution. The sensitivity is achieved by using a cylindrical crystal, which gives a closed geometry with large solid angles. A de-centralized readout scheme where only a local environment around the light excitation is readout supports high-count rates. The high resolution is achieved by using an optimized crystal configuration. A 12 mm crystal plus 12 mm light guide combination gave an intrinsic spatial resolution better than 3.5 mm (140 keV) in a prototype system. Simulations show that a modified configuration can improve this value. A cylindrical configuration with a rotating collimator significantly simplifies the mechanical design of the gantry. The data acquisition and control system uses early digitization and subsequent digital signal processing to extract timing and amplitude information, and monitors the position of the collimator. The readout system consists of 12 or more modules each based on programmable logic and a digital signal processor. The modules send data to a PC file server-reconstruction engine via a Firewire (IEEE-1394) network.
Koren, Katja; Pišot, Rado; Šimunič, Boštjan
2016-05-01
To determine the effects of a moderate-intensity active workstation on time and error during simulated office work. The aim of the study was to analyse simultaneous work and exercise for non-sedentary office workers. We monitored oxygen uptake, heart rate, sweating stains area, self-perceived effort, typing test time with typing error count and cognitive performance during 30 min of exercise with no cycling or cycling at 40 and 80 W. Compared baseline, we found increased physiological responses at 40 and 80 W, which corresponds to moderate physical activity (PA). Typing time significantly increased by 7.3% (p = 0.002) in C40W and also by 8.9% (p = 0.011) in C80W. Typing error count and cognitive performance were unchanged. Although moderate intensity exercise performed on cycling workstation during simulated office tasks increases working task execution time with, it has moderate effect size; however, it does not increase the error rate. Participants confirmed that such a working design is suitable for achieving the minimum standards for daily PA during work hours. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Estimation of population trajectories from count data
Link, W.A.; Sauer, J.R.
1997-01-01
Monitoring of changes in animal population size is rarely possible through complete censuses; frequently, the only feasible means of monitoring changes in population size is to use counts of animals obtained by skilled observers as indices to abundance. Analysis of changes in population size can be severely biased if factors related to the acquisition of data are not adequately controlled for. In particular we identify two types of observer effects: these correspond to baseline differences in observer competence, and to changes through time in the ability of individual observers. We present a family of models for count data in which the first of these observer effects is treated as a nuisance parameter. Conditioning on totals of negative binomial counts yields a Dirichlet compound multinomial vector for each observer. Quasi-likelihood is used to estimate parameters related to population trajectory and other parameters of interest; model selection is carried out on the basis of Akaike's information criterion. An example is presented using data on Wood thrush from the North American Breeding Bird Survey.
Yu, Han; Qi, Zhijiang; Zhao, Lianxing; Shao, Rui; Fang, Yingying; Li, Chunsheng
2016-12-01
Sepsis is a life-threatening response to infection with a high mortality rate. In order to explore the prognostic value of dynamic monitoring of cellular immunity during late severe sepsis, we assessed levels of Tlymphocyte subsets, the human leukocyte antigen D-related (HLA-DR), and the high mobility group box-1 (HMGB1) protein. Study participants included 247 consecutive severe sepsis patients who were admitted to Beijing ChaoYang Hospital's Emergency Intensive Care Unit. Patients were divided into survivors and non-survivors based on 90-day survival rates, and clinical data were collected. T-lymphocyte subsets on days 1 and 7, HLA-DR on days 1 and 12, and HMGB1 on days 1, 3, 5, 7, and 12 were analyzed. Counts of CD3+, CD3+CD4+, and CD3+CD8+ T cells on day 1 in non-survivors were lower than those in survivors. By day 7, counts of all three types of T cells had increased in both survivors and non-survivors, but CD3+ and CD3+CD8+ T cells remained lower in non-survivors than in survivors. There was no significant difference in HLA-DR levels between survivors and non-survivors on day 1, but HLA-DR levels increased in survivors and decreased in non-survivors by day 12. In contrast, over days 1 - 12, HMGB1 levels increased in non-survivors and decreased in survivors. Patients with severe sepsis present with cellular immune dysfunction and persistent chronic inflammation, both of which may lead to death in the late phase of severe sepsis. Dynamic monitoring of indicators of cellular immunity and HMGB1 is useful for evaluating the immune status, chronic inflammation processes, and prognoses of patients with severe sepsis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eleon, Cyrille; Passard, Christian; Hupont, Nicolas
2015-07-01
Nuclear measurements are used at AREVA NC/La Hague for the monitoring of spent fuel reprocessing. The process control is based on gamma-ray spectroscopy, passive neutron counting and active neutron interrogation, and gamma transmission measurements. The main objectives are criticality and safety, online process monitoring, and the determination of the residual fissile mass and activities in the metallic waste remained after fuel shearing and dissolution (empty hulls, grids, end pieces), which are put in radioactive waste drums before compaction. The whole monitoring system is composed of eight measurement stations which will be described in this paper. The main measurement stations no.more » 1, 3 and 7 are needed for criticality control. Before fuel element shearing for dissolution, station no. 1 allows determining the burn-up of the irradiated fuel by gamma-ray spectroscopy with HP Ge (high purity germanium) detectors. The burn-up is correlated to the {sup 137}Cs and {sup 134}Cs gamma emission rates. The fuel maximal mass which can be loaded in one bucket of the dissolver is estimated from the lowest burn-up fraction of the fuel element. Station no. 3 is dedicated to the control of the correct fuel dissolution, which is performed with a {sup 137}Cs gamma ray measurement with a HP Ge detector. Station no. 7 allows estimating the residual fissile mass in the drums filled with the metallic residues, especially in the hulls, from passive neutron counting (spontaneous fission and alpha-n reactions) and active interrogation (fission prompt neutrons induced by a pulsed neutron generator) with proportional {sup 3}He detectors. The measurement stations have been validated for the reprocessing of Uranium Oxide (UOX) fuels with a burn-up rate up to 60 GWd/t. This paper presents a brief overview of the current status of the nuclear measurement stations. (authors)« less
Design of a portable dose rate detector based on a double Geiger-Mueller counter
NASA Astrophysics Data System (ADS)
Wang, Peng; Tang, Xiao-Bin; Gong, Pin; Huang, Xi; Wen, Liang-Sheng; Han, Zhen-Yang; He, Jian-Ping
2018-01-01
A portable dose rate detector was designed to monitor radioactive pollution and radioactive environments. The portable dose detector can measure background radiation levels (0.1 μSv/h) to nuclear accident radiation levels (>10 Sv/h). Both automatic switch technology of a double Geiger-Mueller counter and time-to-count technology were adopted to broaden the measurement range of the instrument. Global positioning systems and the 3G telecommunication protocol were installed to prevent radiation damage to the human body. In addition, the Monte Carlo N-Particle code was used to design the thin layer of metal for energy compensation, which was used to flatten energy response The portable dose rate detector has been calibrated by the standard radiation field method, and it can be used alone or in combination with additional radiation detectors.
[Intelligent watch system for health monitoring based on Bluetooth low energy technology].
Wang, Ji; Guo, Hailiang; Ren, Xiaoli
2017-08-01
According to the development status of wearable technology and the demand of intelligent health monitoring, we studied the multi-function integrated smart watches solution and its key technology. First of all, the sensor technology with high integration density, Bluetooth low energy (BLE) and mobile communication technology were integrated and used in develop practice. Secondly, for the hardware design of the system in this paper, we chose the scheme with high integration density and cost-effective computer modules and chips. Thirdly, we used real-time operating system FreeRTOS to develop the friendly graphical interface interacting with touch screen. At last, the high-performance application software which connected with BLE hardware wirelessly and synchronized data was developed based on android system. The function of this system included real-time calendar clock, telephone message, address book management, step-counting, heart rate and sleep quality monitoring and so on. Experiments showed that the collecting data accuracy of various sensors, system data transmission capacity, the overall power consumption satisfy the production standard. Moreover, the system run stably with low power consumption, which could realize intelligent health monitoring effectively.
O' Donoghue, Deirdre; Kennedy, Norelee
2014-11-01
The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, walking time, transitions and step count for both legs in young people with hemiplegic and asymmetric diplegic CP. Seventeen participants with CP Gross Motor Function Classification System level I completed two video recorded test protocols that involved wearing an activPAL™ activity monitor on alternate legs. Agreement between observed video recorded data and activPAL™ activity monitor data was assessed using the Bland and Altman (BA) method and intraclass correlation coefficients (ICC 3,1). There was perfect agreement for transitions and high agreement for sitting (BA mean differences (MD): -1.8 and -1.8 s; ICCs: 0.49 and 0.95) standing (MD: 0.8 and 0.1 s; ICCs: 0.59 and 0.98) walking (MD: 1 and 1.1 s; ICCs: 0.99 and 0.94) timings and low agreement for step count (MD: 4.1 and 2.8 steps; ICCs: 0.96 and 0.95) for both legs. This study found clinically acceptable agreement with direct observation for all activPAL™ activity monitor functions, except for step count measurement with respect to the range of measurement values obtained for both legs in this study population.
Ziegler, Ildikó; Borbély-Jakab, Judit; Sugó, Lilla; Kovács, Réka J
2017-01-01
In this case study, the principles of quality risk management were applied to review sampling points and monitoring frequencies in the hormonal tableting unit of a formulation development pilot plant. In the cleanroom area, premises of different functions are located. Therefore a general method was established for risk evaluation based on the Hazard Analysis and Critical Control Points (HACCP) method to evaluate these premises (i.e., production area itself and ancillary clean areas) from the point of view of microbial load and state in order to observe whether the existing monitoring program met the emerged advanced monitoring practice. LAY ABSTRACT: In pharmaceutical production, cleanrooms are needed for the manufacturing of final dosage forms of drugs-intended for human or veterinary use-in order to protect the patient's weakened body from further infections. Cleanrooms are premises with a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size or number of microorganisms (i.e. microbial count) per surface area. To ensure a low microbial count over time, microorganisms are detected and counted by environmental monitoring methods regularly. It is reasonable to find the easily infected places by risk analysis to make sure the obtained results really represent the state of the whole room. This paper presents a risk analysis method for the optimization of environmental monitoring and verification of the suitability of the method. © PDA, Inc. 2017.
Testing self-regulation interventions to increase walking using factorial randomized N-of-1 trials.
Sniehotta, Falko F; Presseau, Justin; Hobbs, Nicola; Araújo-Soares, Vera
2012-11-01
To investigate the suitability of N-of-1 randomized controlled trials (RCTs) as a means of testing the effectiveness of behavior change techniques based on self-regulation theory (goal setting and self-monitoring) for promoting walking in healthy adult volunteers. A series of N-of-1 RCTs in 10 normal and overweight adults ages 19-67 (M = 36.9 years). We randomly allocated 60 days within each individual to text message-prompted daily goal-setting and/or self-monitoring interventions in accordance with a 2 (step-count goal prompt vs. alternative goal prompt) × 2 (self-monitoring: open vs. blinded Omron-HJ-113-E pedometer) factorial design. Aggregated data were analyzed using random intercept multilevel models. Single cases were analyzed individually. The primary outcome was daily pedometer step counts over 60 days. Single-case analyses showed that 4 participants significantly increased walking: 2 on self-monitoring days and 2 on goal-setting days, compared with control days. Six participants did not benefit from the interventions. In aggregated analyses, mean step counts were higher on goal-setting days (8,499.9 vs. 7,956.3) and on self-monitoring days (8,630.3 vs. 7,825.9). Multilevel analyses showed a significant effect of the self-monitoring condition (p = .01), the goal-setting condition approached significance (p = .08), and there was a small linear increase in walking over time (p = .03). N-of-1 randomized trials are a suitable means to test behavioral interventions in individual participants.
NASA Astrophysics Data System (ADS)
Zibaii, M. I.; Kazemi, A.; Latifi, H.; Karimi Azar, M.; Hosseini, S. M.; Ghezelaiagh, M. H.
2010-09-01
A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-L-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria.
Kanejima, Yuji; Kitamura, Masahiro; Izawa, Kazuhiro P
2018-04-30
It is important to encourage physical activity in patients with cardiovascular disease (CVD), and self-monitoring is considered to contribute to increased physical activity. However, the effects of self-monitoring on CVD patients remain to be established. In this study, we examined the influence of self-monitoring on physical activity of patients with CVD via a systematic review and meta-analysis. Screening of randomized controlled trials only was undertaken twice on PubMed (date of appraisal: August 29, 2017). The inclusion criteria included outpatients with CVD, interventions for them, daily step counts as physical activity included in the outcome, and self-monitoring included in the intervention. Assessments of the risk of bias and meta-analysis in relation to the mean change of daily step counts were conducted to verify the effects of self-monitoring. From 205 studies retrieved on PubMed, six studies were included, with the oldest study published in 2005. Participants included 693 patients of whom 541 patients completed each study program. Their mean age was 60.8 years, and the ratio of men was 79.6%. From these 6 studies, a meta-analysis was conducted with 269 patients of 4 studies including only RCTs with step counts in the intervention group and the control group, and self-monitoring significantly increased physical activity (95% confidence interval, 1916-3090 steps per day, p < 0.05). The average intervention period was about 5 months. Moreover, four studies involved intervention via the internet, and five studies confirmed the use of self-monitoring combined with other behavior change techniques. The results suggest that self-monitoring of physical activity by patients with CVD has a significantly positive effect on their improvement. Moreover, the trend toward self-monitoring combined with setting counseling and activity goals, and increased intervention via the internet, may lead to the future development and spread of self-monitoring for CVD patients.
Liu, Yan; Li, Xiaohong; Johnson, Margaret; Smith, Collette; Kamarulzaman, Adeeba bte; Montaner, Julio; Mounzer, Karam; Saag, Michael; Cahn, Pedro; Cesar, Carina; Krolewiecki, Alejandro; Sanne, Ian; Montaner, Luis J.
2012-01-01
Background Global programs of anti-HIV treatment depend on sustained laboratory capacity to assess treatment initiation thresholds and treatment response over time. Currently, there is no valid alternative to CD4 count testing for monitoring immunologic responses to treatment, but laboratory cost and capacity limit access to CD4 testing in resource-constrained settings. Thus, methods to prioritize patients for CD4 count testing could improve treatment monitoring by optimizing resource allocation. Methods and Findings Using a prospective cohort of HIV-infected patients (n = 1,956) monitored upon antiretroviral therapy initiation in seven clinical sites with distinct geographical and socio-economic settings, we retrospectively apply a novel prediction-based classification (PBC) modeling method. The model uses repeatedly measured biomarkers (white blood cell count and lymphocyte percent) to predict CD4+ T cell outcome through first-stage modeling and subsequent classification based on clinically relevant thresholds (CD4+ T cell count of 200 or 350 cells/µl). The algorithm correctly classified 90% (cross-validation estimate = 91.5%, standard deviation [SD] = 4.5%) of CD4 count measurements <200 cells/µl in the first year of follow-up; if laboratory testing is applied only to patients predicted to be below the 200-cells/µl threshold, we estimate a potential savings of 54.3% (SD = 4.2%) in CD4 testing capacity. A capacity savings of 34% (SD = 3.9%) is predicted using a CD4 threshold of 350 cells/µl. Similar results were obtained over the 3 y of follow-up available (n = 619). Limitations include a need for future economic healthcare outcome analysis, a need for assessment of extensibility beyond the 3-y observation time, and the need to assign a false positive threshold. Conclusions Our results support the use of PBC modeling as a triage point at the laboratory, lessening the need for laboratory-based CD4+ T cell count testing; implementation of this tool could help optimize the use of laboratory resources, directing CD4 testing towards higher-risk patients. However, further prospective studies and economic analyses are needed to demonstrate that the PBC model can be effectively applied in clinical settings. Please see later in the article for the Editors' Summary PMID:22529752
All-Sky Earth Occultation Observations with the Fermi Gamma Ray Burst Monitor
NASA Technical Reports Server (NTRS)
Wilson-Hodge, C. A.; Beklen, E.; Bhat, P. N.; Briggs, M.; Camero-Arranz, A.; Case, G.; Chaplin, V.; Cherry, M.; Connaughton, V.; Finger, M.;
2010-01-01
Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. New sources are added to our catalog as they become active or upon request. In addition to Earth occultations, we have observed numerous occultations with Fermi's solar panels. We will present early results. Regularly updated results will be found on our website http://gammaray.nsstc.nasa.gov/gbm/science/occultation.
NASA Astrophysics Data System (ADS)
Bernstein, A.; Allen, M.; Bowden, N.; Brennan, J.; Carr, D. J.; Estrada, J.; Hagmann, C.; Lund, J. C.; Madden, N. W.; Winant, C. D.
2005-09-01
Our Lawrence Livermore National Laboratory/Sandia National Laboratories collaboration has deployed a cubic-meter-scale antineutrino detector to demonstrate non-intrusive and automatic monitoring of the power levels and plutonium content of a nuclear reactor. Reactor monitoring of this kind is required for all non-nuclear weapons states under the Nuclear Nonproliferation Treaty (NPT), and is implemented by the International Atomic Energy Agency (IAEA). Since the antineutrino count rate and energy spectrum depend on the relative yields of fissioning isotopes in the reactor core, changes in isotopic composition can be observed without ever directly accessing the core. Data from a cubic meter scale antineutrino detector, coupled with the well-understood principles that govern the core's evolution in time, can be used to determine whether the reactor is being operated in an illegitimate way. Our group has deployed a detector at the San Onofre reactor site in California to demonstrate this concept. This paper describes the concept and shows preliminary results from 8 months of operation.
A spatial editing and validation process for short count traffic data : final report, July 2006.
DOT National Transportation Integrated Search
2006-07-07
The Traffic Survey Unit (TSU) manages 40,000 traffic monitoring stations, of which 25,000 are updated annually. : These counts obtained by TSU play a crucial role in allocation of resources for the maintenance, upgrade, and : expansion of traffic inf...
The ability of a battery of genetic monitoring tests to detect occupational formaldehyde exposure in a population of a hospital autopsy service workers was investigated. Eleven exposed individuals and 11 matched controls were evaluated for sperm count, abnormal sperm morphology a...
Kinnunen, Tarja I; Tennant, Peter W G; McParlin, Catherine; Poston, Lucilla; Robson, Stephen C; Bell, Ruth
2011-06-27
Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women.
Testing a Threshold-Based Bed Bug Management Approach in Apartment Buildings.
Singh, Narinderpal; Wang, Changlu; Zha, Chen; Cooper, Richard; Robson, Mark
2017-07-26
We tested a threshold-based bed bug ( Cimex lectularius L.) management approach with the goal of achieving elimination with minimal or no insecticide application. Thirty-two bed bug infested apartments were identified. These apartments were divided into four treatment groups based on apartment size and initial bed bug count, obtained through a combination of visual inspection and bed bug monitors: I- Non-chemical only in apartments with 1-12 bed bug count, II- Chemical control only in apartments with 1-12 bed bug count, III- Non-chemical and chemical control in apartments with >12 bed bug count, and IV- Chemical control only in apartments with ≥11 bed bug count. All apartments were monitored or treated once every two weeks for a maximum of 28 wk. Treatment I eliminated bed bugs in a similar amount of time to treatment II. Time to eliminate bed bugs was similar between treatment III and IV but required significantly less insecticide spray in treatment III than that in treatment IV. A threshold-based management approach (non-chemical only or non-chemical and chemical) can eliminate bed bugs in a similar amount of time, using little to no pesticide compared to a chemical only approach.
Testing a Threshold-Based Bed Bug Management Approach in Apartment Buildings
Singh, Narinderpal; Zha, Chen; Cooper, Richard; Robson, Mark
2017-01-01
We tested a threshold-based bed bug (Cimex lectularius L.) management approach with the goal of achieving elimination with minimal or no insecticide application. Thirty-two bed bug infested apartments were identified. These apartments were divided into four treatment groups based on apartment size and initial bed bug count, obtained through a combination of visual inspection and bed bug monitors: I- Non-chemical only in apartments with 1–12 bed bug count, II- Chemical control only in apartments with 1–12 bed bug count, III- Non-chemical and chemical control in apartments with >12 bed bug count, and IV- Chemical control only in apartments with ≥11 bed bug count. All apartments were monitored or treated once every two weeks for a maximum of 28 wk. Treatment I eliminated bed bugs in a similar amount of time to treatment II. Time to eliminate bed bugs was similar between treatment III and IV but required significantly less insecticide spray in treatment III than that in treatment IV. A threshold-based management approach (non-chemical only or non-chemical and chemical) can eliminate bed bugs in a similar amount of time, using little to no pesticide compared to a chemical only approach. PMID:28933720
Single photon counting linear mode avalanche photodiode technologies
NASA Astrophysics Data System (ADS)
Williams, George M.; Huntington, Andrew S.
2011-10-01
The false count rate of a single-photon-sensitive photoreceiver consisting of a high-gain, low-excess-noise linear-mode InGaAs avalanche photodiode (APD) and a high-bandwidth transimpedance amplifier (TIA) is fit to a statistical model. The peak height distribution of the APD's multiplied dark current is approximated by the weighted sum of McIntyre distributions, each characterizing dark current generated at a different location within the APD's junction. The peak height distribution approximated in this way is convolved with a Gaussian distribution representing the input-referred noise of the TIA to generate the statistical distribution of the uncorrelated sum. The cumulative distribution function (CDF) representing count probability as a function of detection threshold is computed, and the CDF model fit to empirical false count data. It is found that only k=0 McIntyre distributions fit the empirically measured CDF at high detection threshold, and that false count rate drops faster than photon count rate as detection threshold is raised. Once fit to empirical false count data, the model predicts the improvement of the false count rate to be expected from reductions in TIA noise and APD dark current. Improvement by at least three orders of magnitude is thought feasible with further manufacturing development and a capacitive-feedback TIA (CTIA).
DOE Office of Scientific and Technical Information (OSTI.GOV)
March-Leuba, Jose A; Uckan, Taner; Gunning, John E
2010-01-01
The expected increased demand in fuel for nuclear power plants, combined with the fact that a significant portion of the current supply from the blend down of weapons-source material will soon be coming to an end, has led to the need for new sources of enriched uranium for nuclear fuel. As a result, a number of countries have announced plans, or are currently building, gaseous centrifuge enrichment plants (GCEPs) to supply this material. GCEPs have the potential to produce uranium at enrichments above the level necessary for nuclear fuel purposes-enrichments that make the uranium potentially usable for nuclear weapons. Asmore » a result, there is a critical need to monitor these facilities to ensure that nuclear material is not inappropriately enriched or diverted for unintended use. Significant advances have been made in instrument capability since the current International Atomic Energy Agency (IAEA) monitoring methods were developed. In numerous cases, advances have been made in other fields that have the potential, with modest development, to be applied in safeguards applications at enrichment facilities. A particular example of one of these advances is the flow and enrichment monitor (FEMO). (See Gunning, J. E. et al., 'FEMO: A Flow and Enrichment Monitor for Verifying Compliance with International Safeguards Requirements at a Gas Centrifuge Enrichment Facility,' Proceedings of the 8th International Conference on Facility Operations - Safeguards Interface. Portland, Oregon, March 30-April 4th, 2008.) The FEMO is a conceptual instrument capable of continuously measuring, unattended, the enrichment and mass flow of {sup 235}U in pipes at a GCEP, and consequently increase the probability that the potential production of HEU and/or diversion of fissile material will be detected. The FEMO requires no piping penetrations and can be installed on pipes containing the flow of uranium hexafluoride (UF{sub 6}) at a GCEP. This FEMO consists of separate parts, a flow monitor (FM) and an enrichment monitor (EM). Development of the FM is primarily the responsibility of Oak Ridge National Laboratory, and development of the EM is primarily the responsibility of Los Alamos National Laboratory. The FM will measure {sup 235}U mass flow rate by combining information from measuring the UF{sub 6} volumetric flow rate and the {sup 235}U density. The UF{sub 6} flow rate will be measured using characteristics of the process pumps used in product and tail UF{sub 6} header process lines of many GCEPs, and the {sup 235}U density will be measured using commercially available sodium iodide (NaI) gamma ray scintillation detectors. This report describes the calibration of the portion of the FM that measures the {sup 235}U density. Research has been performed to define a methodology and collect data necessary to perform this calibration without the need for plant declarations. The {sup 235}U density detector is a commercially available system (GammaRad made by Amptek, www.amptek.com) that contains the NaI crystal, photomultiplier tube, signal conditioning electronics, and a multichannel analyzer (MCA). Measurements were made with the detector system installed near four {sup 235}U sources. Two of the sources were made of solid uranium, and the other two were in the form of UF{sub 6} gas in aluminum piping. One of the UF{sub 6} gas sources was located at ORNL and the other at LANL. The ORNL source consisted of two pipe sections (schedule 40 aluminum pipe of 4-inch and 8-inch outside diameter) with 5.36% {sup 235}U enrichment, and the LANL source was a 4-inch schedule 40 aluminum pipe with 3.3% {sup 235}U enrichment. The configurations of the detector on these test sources, as well as on long straight pipe configurations expected to exist at GCEPs, were modeled using the computer code MCNP. The results of the MCNP calculations were used to define geometric correction factors between the test source and the GCEP application. Using these geometric correction factors, the experimental 186 keV counts in the test geometry were extrapolated to the expected GCEP geometry, and calibration curves were developed. A unique method to analyze the measurement was also developed that separated the detector spectrum into the five detectable decay gamma rays emitted by {sup 235}U in the 120 to 200 keV energy range. This analysis facilitated the assignment of a consistent value for the detector counts originating from {sup 235}U decays at 186 keV. This value is also more accurate because it includes the counts from gamma energies other than 186 keV, which results in increased counting statistics for the same measurement time. The 186 keV counts expected as a function of pressure and enrichment are presented in the body of this report. The main result of this research is a calibration factor for 4-inch and 8-inch schedule 40 aluminum pipes. For 4-inch pipes, the {sup 235}U density is 0.62 {sup 235}U g/m{sup 3} per each measured 186 keV count.« less
Black, James; Gerdtz, Marie; Nicholson, Pat; Crellin, Dianne; Browning, Laura; Simpson, Julie; Bell, Lauren; Santamaria, Nick
2015-05-01
Respiratory rate is an important sign that is commonly either not recorded or recorded incorrectly. Mobile phone ownership is increasing even in resource-poor settings. Phone applications may improve the accuracy and ease of counting of respiratory rates. The study assessed the reliability and initial users' impressions of four mobile phone respiratory timer approaches, compared to a 60-second count by the same participants. Three mobile applications (applying four different counting approaches plus a standard 60-second count) were created using the Java Mobile Edition and tested on Nokia C1-01 phones. Apart from the 60-second timer application, the others included a counter based on the time for ten breaths, and three based on the time interval between breaths ('Once-per-Breath', in which the user presses for each breath and the application calculates the rate after 10 or 20 breaths, or after 60s). Nursing and physiotherapy students used the applications to count respiratory rates in a set of brief video recordings of children with different respiratory illnesses. Limits of agreement (compared to the same participant's standard 60-second count), intra-class correlation coefficients and standard errors of measurement were calculated to compare the reliability of the four approaches, and a usability questionnaire was completed by the participants. There was considerable variation in the counts, with large components of the variation related to the participants and the videos, as well as the methods. None of the methods was entirely reliable, with no limits of agreement better than -10 to +9 breaths/min. Some of the methods were superior to the others, with ICCs from 0.24 to 0.92. By ICC the Once-per-Breath 60-second count and the Once-per-Breath 20-breath count were the most consistent, better even than the 60-second count by the participants. The 10-breath approaches performed least well. Users' initial impressions were positive, with little difference between the applications found. This study provides evidence that applications running on simple phones can be used to count respiratory rates in children. The Once-per-Breath methods are the most reliable, outperforming the 60-second count. For children with raised respiratory rates the 20-breath version of the Once-per-Breath method is faster, so it is a more suitable option where health workers are under time pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cosmic ray intensity gradients in the solar system
NASA Technical Reports Server (NTRS)
Mckibben, R. B.
1975-01-01
Recent progress in the determination of cosmic-ray intensity gradients is reviewed. Direct satellite measurements of the integral gradient are described together with various types of indirect measurements, including measurements of the Ar-37/Ar-39 ratio in samples from the Lost City meteorite, studies of anisotropies in neutron-monitor counting rates, and analysis of the sidereal diurnal anisotropy observed at a single point on earth. Nucleonic radial gradients and electron gradients measured by satellites in differential energy windows are discussed, and theoretical studies of the physical processes involved in these gradients are summarized. Observations of intensity gradients in heliographic latitude are reported.
[Therapeutic Efficacy of VICP+L-ASP/TKI on Adult Patients with B-ALL].
Shen, Ming-Fang; Wei, Ju-Ying; Yu, Wen-Juan; Wang, Jing-Han; Tong, Hong-Yan; Meng, Hai-Tao; Mai, Wen-Yuan; Qian, Wen-Bin; Jin, Jie
2016-12-01
To evaluate the therapeutic efficacy of VICP+L-ASP/TKI on adult patients with B-ALL and to explore the influence factors. Forty-one adult B-ALL patients treated with VICP+L-ASP/TKI from August 2008 to June 2014 were following-up. The complete remission(CR) rate, toxicity, overall survival(OS) and event free survival(EFS) after induction treatment were analyzed, the therapeutic outcome of patients between different risk stratification subgroups was compared, the influence of standardized consolidatory and maintaining treatment as well as allogeneic hematopoietic stem cell transplantation(allo-HSCT) on survival time was analyzed. The early death not occurred in 41 patients with B-ALL including 37 cases with CR; the CR rate of 1 course treatment was 90.2%. The follow-up time lasted to March 17, 2015, the median follow-up time was 25(9-79) months; the 1 year OS rate was 75.3%, the EFS rate was 58.3%. Analysis of risk factors showed that the initial WBC count over 30×10 9 /L, LDH over 250 U/L and minimal residual disease(MRD) over 10 -4 after treatment were poor prognostic factors. After remission, the standardized consolidatory treatment or allo-HSCT according to the "2012 China adult ALL diagnosis and treatment expert consensus" could improve long-term survival, 3 years OS rate was 73.8% and 61.5% respectively, 3 years EFS were 63.5% and 65.7% respectively. The main toxic and side effects were hematologic reactions, the hematologic adverse reaction of IV grade was observed in 97.6%(40/41) during induction treatment. Induction chemotherapy based on VICP+L-ASP/TKI and standardized consolidatory after remission according to the "2012 China adult acute lymphoblastic leukemia diagnosis and treatment expert consensus" can improve the therapeutic efficacy. The allo-HSCT should be actively performed for B-ALL paients with high risk(elevated initial WBC count and LDH level); at some time, the regularly monitoring MRD and adjusting therapeutic protocol according to monitoring result can promote the prognosis of adult B-ALL patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taneja, S; Fru, L Che; Desai, V
Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Applemore » iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.« less
Cerebellar pathology in childhood-onset vs. adult-onset essential tremor.
Louis, Elan D; Kuo, Sheng-Han; Tate, William J; Kelly, Geoffrey C; Faust, Phyllis L
2017-10-17
Although the incidence of ET increases with advancing age, the disease may begin at any age, including childhood. The question arises as to whether childhood-onset ET cases manifest the same sets of pathological changes in the cerebellum as those whose onset is during adult life. We quantified a broad range of postmortem features (Purkinje cell [PC] counts, PC axonal torpedoes, a host of associated axonal changes [PC axonal recurrent collateral count, PC thickened axonal profile count, PC axonal branching count], heterotopic PCs, and basket cell rating) in 60 ET cases (11 childhood-onset and 49 adult-onset) and 30 controls. Compared to controls, childhood-onset ET cases had lower PC counts, higher torpedo counts, higher heterotopic PC counts, higher basket cell plexus rating, and marginally higher PC axonal recurrent collateral counts. The median PC thickened axonal profile count and median PC axonal branching count were two to five times higher in childhood-onset ET than controls, but the differences did not reach statistical significance. Childhood-onset and adult-onset ET had similar PC counts, torpedo counts, heterotopic PC counts, basket cell plexus rating, PC axonal recurrent collateral counts, PC thickened axonal profile count and PC axonal branching count. In conclusion, we found that childhood-onset and adult-onset ET shared similar pathological changes in the cerebellum. The data suggest that pathological changes we have observed in the cerebellum in ET are a part of the pathophysiological cascade of events in both forms of the disease and that both groups seem to reach the same pathological endpoints at a similar age of death. Copyright © 2017 Elsevier B.V. All rights reserved.
Point count length and detection of forest neotropical migrant birds
Dawson, D.K.; Smith, D.R.; Robbins, C.S.; Ralph, C. John; Sauer, John R.; Droege, Sam
1995-01-01
Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences existed among years or observers in both the probability of detecting the species and in the rate at which individuals are counted. We demonstrate the consequence that variability in species' detection probabilities can have on estimates of population change, and discuss ways for reducing this source of bias in point count studies.
Probing Jupiter's Radiation Environment with Juno-UVS
NASA Astrophysics Data System (ADS)
Kammer, J.; Gladstone, R.; Greathouse, T. K.; Hue, V.; Versteeg, M. H.; Davis, M. W.; Santos-Costa, D.; Becker, H. N.; Bolton, S. J.; Connerney, J. E. P.; Levin, S.
2017-12-01
While primarily designed to observe photon emission from the Jovian aurora, Juno's Ultraviolet Spectrograph (Juno-UVS) has also measured background count rates associated with penetrating high-energy radiation. These background counts are distinguishable from photon events, as they are generally spread evenly across the entire array of the Juno-UVS detector, and as the spacecraft spins, they set a baseline count rate higher than the sky background rate. During eight perijove passes, this background radiation signature has varied significantly on both short (spin-modulated) timescales, as well as longer timescales ( minutes to hours). We present comparisons of the Juno-UVS data across each of the eight perijove passes, with a focus on the count rate that can be clearly attributed to radiation effects rather than photon events. Once calibrated to determine the relationship between count rate and penetrating high-energy radiation (e.g., using existing GEANT models), these in situ measurements by Juno-UVS will provide additional constraints to radiation belt models close to the planet.
Bannerman, J A; Costamagna, A C; McCornack, B P; Ragsdale, D W
2015-06-01
Generalist natural enemies play an important role in controlling soybean aphid, Aphis glycines (Hemiptera: Aphididae), in North America. Several sampling methods are used to monitor natural enemy populations in soybean, but there has been little work investigating their relative bias, precision, and efficiency. We compare five sampling methods: quadrats, whole-plant counts, sweep-netting, walking transects, and yellow sticky cards to determine the most practical methods for sampling the three most prominent species, which included Harmonia axyridis (Pallas), Coccinella septempunctata L. (Coleoptera: Coccinellidae), and Orius insidiosus (Say) (Hemiptera: Anthocoridae). We show an important time by sampling method interaction indicated by diverging community similarities within and between sampling methods as the growing season progressed. Similarly, correlations between sampling methods for the three most abundant species over multiple time periods indicated differences in relative bias between sampling methods and suggests that bias is not consistent throughout the growing season, particularly for sticky cards and whole-plant samples. Furthermore, we show that sticky cards produce strongly biased capture rates relative to the other four sampling methods. Precision and efficiency differed between sampling methods and sticky cards produced the most precise (but highly biased) results for adult natural enemies, while walking transects and whole-plant counts were the most efficient methods for detecting coccinellids and O. insidiosus, respectively. Based on bias, precision, and efficiency considerations, the most practical sampling methods for monitoring in soybean include walking transects for coccinellid detection and whole-plant counts for detection of small predators like O. insidiosus. Sweep-netting and quadrat samples are also useful for some applications, when efficiency is not paramount. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Improved survival in HIV treatment programs in Asia
De La Mata, Nicole L; Kumarasamy, Nagalingeswaran; Khol, Vohith; Ng, Oon Tek; Van Nguyen, Kinh; Merati, Tuti Parwati; Pham, Thuy Thanh; Lee, Man Po; Durier, Nicolas; Law, Matthew
2016-01-01
Background Antiretroviral treatment (ART) for HIV-positive patients has expanded rapidly in Asia over the last ten years. Our study aimed to describe the time trends and risk factors for overall survival in patients receiving first-line ART in Asia. Methods We included HIV-positive adult patients who initiated ART between 2003–2013 (n=16 546), from seven sites across six Asia-Pacific countries. Patient follow-up was to May 2014. We compared survival for each country and overall by time period of ART initiation using Kaplan-Meier curves. Factors associated with mortality were assessed using Cox regression, stratified by site. We also summarized first-line ART regimens, CD4 count at ART initiation, and CD4 and HIV viral load testing frequencies. Results There were 880 deaths observed over 54 532 person-years of follow-up, a crude rate of 1.61 (1.51, 1.72) per 100 person-years. Survival significantly improved in more recent years of ART initiation. The survival probabilities at 4 years follow-up for those initiating ART in 2003–05 was 92.1%, 2006–09 was 94.3% and 2010–2013 was 94.5% (p<0.001). Factors associated with higher mortality risk included initiating ART in earlier time periods, older age, male sex, injecting drug use as HIV exposure and lower pre-ART CD4 count. Concurrent with improved survival was increased tenofovir use, ART initiation at higher CD4 counts, and greater monitoring of CD4 and HIV viral load. Conclusions Our results suggest that HIV-positive patients from Asia have improved survival in more recent years of ART initiation. This is likely a consequence of improvements in treatment and, patient management and monitoring over time. PMID:26961354
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cammin, Jochen, E-mail: jcammin1@jhmi.edu, E-mail: ktaguchi@jhmi.edu; Taguchi, Katsuyuki, E-mail: jcammin1@jhmi.edu, E-mail: ktaguchi@jhmi.edu; Xu, Jennifer
Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra andmore » count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.« less
Cammin, Jochen; Xu, Jennifer; Barber, William C.; Iwanczyk, Jan S.; Hartsough, Neal E.; Taguchi, Katsuyuki
2014-01-01
Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi , “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COVW), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COVW's less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COVW was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE. PMID:24694136
34 CFR 300.644 - Annual report of children served-criteria for counting children.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 34 Education 2 2012-07-01 2012-07-01 false Annual report of children served-criteria for counting children. 300.644 Section 300.644 Education Regulations of the Offices of the Department of Education... STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES Monitoring, Enforcement, Confidentiality, and...
34 CFR 300.644 - Annual report of children served-criteria for counting children.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 34 Education 2 2013-07-01 2013-07-01 false Annual report of children served-criteria for counting children. 300.644 Section 300.644 Education Regulations of the Offices of the Department of Education... STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES Monitoring, Enforcement, Confidentiality, and...
34 CFR 300.644 - Annual report of children served-criteria for counting children.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 34 Education 2 2010-07-01 2010-07-01 false Annual report of children served-criteria for counting children. 300.644 Section 300.644 Education Regulations of the Offices of the Department of Education... STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES Monitoring, Enforcement, Confidentiality, and...
34 CFR 300.644 - Annual report of children served-criteria for counting children.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 34 Education 2 2011-07-01 2010-07-01 true Annual report of children served-criteria for counting children. 300.644 Section 300.644 Education Regulations of the Offices of the Department of Education... STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES Monitoring, Enforcement, Confidentiality, and...
Nutrition Counts. Massachusetts Nutrition Surveillance System. FY90 Annual Report.
ERIC Educational Resources Information Center
Wiecha, Jean L.; And Others
"Nutrition Counts," the pediatric portion of the Massachusetts Department of Public Health's (MDPH) Nutrition Surveillance System, monitors and describes aspects of nutritional status among groups of young children in the state. This report presents cross-sectional data describing 5,176 infants and young children in Massachusetts. Of…
Is undertransfusion a problem in modern clinical practice?
Hibbs, Stephen; Miles, David; Staves, Julie; Murphy, Michael F
2015-04-01
Significant progress has been made in reducing inappropriate transfusion of blood products. However, there is also a need to monitor for their underutilization in patients who would benefit from transfusion. This study aimed to develop a method to monitor for undertransfusion and conduct a preliminary examination of whether it is a problem in modern clinical practice. All patients with a hemoglobin (Hb) concentration below 6 g/dL or platelet (PLT) count of fewer than 10 × 10(9) /L were identified during a 1-month period in an academic medical center in the United Kingdom. Patients who were transfused within 72 hours of the low reading were excluded from further analysis. For all other patients, records were examined against predefined criteria to ascertain whether the reason for nonadministration of transfusion was justified. During the study period there were 63 eligible Hb readings and 130 eligible PLT counts in 93 patients. Of these, 36 patients were not transfused within 72 hours of the low reading. The majority of nonadministration (n = 28) was justified by either an additional Hb or an additional PLT count on repeat sampling being above the transfusion threshold or the transfusion being medically inappropriate. No documentation was found to indicate that any cases of nonadministration of blood were unjustified. This study did not find that patients with low Hb readings or PLT counts were inappropriately undertransfused. However, systems similar to those described in this study should be developed to monitor for inappropriate undertransfusion as well as continuing efforts to monitor for and reduce inappropriate overtransfusion. © 2014 AABB.
Visual counts as an index of White-Tailed Prairie Dog density
Menkens, George E.; Biggins, Dean E.; Anderson, Stanley H.
1990-01-01
Black-footed ferrets (Mustela nigripes) are depended on prairie dogs (Cynomys spp.) for food and shelter and were historically restricted to prairie dog towns (Anderson et al. 1986). Because ferrets and prairie dogs are closely associated, successful ferret management and conservation depends on successful prairie dog management. A critical component of any management program for ferrets will be monitoring prairie dog population dynamics on towns containing ferrets or on towns proposed as ferret reintroduction sites. Three techniques for estimating prairie dog population size and density are counts of plugged and reopened burrows (Tietjen and Matschke 1982), mark-recapture (Otis et al. 1978; Seber 1982, 1986; Menkens and Anderson 1989), and visual counts (Fagerstone and Biggins 1986, Knowles 1986). The technique of plugging burrows and counting the number reopened by prairie dogs is too time and labor intensive for population evaluation on a large number of towns or over large areas. Total burrow counts are not correlated with white-tailed prairie dog (C. leucurus) densities and thus cannot be used for populated evaluation (Menkens et al. 1988). Mark-recapture requires trapping that is expensive and time and labor intensive. Monitoring a large number of prairie dog populations using mark-recapture would be difficult. Alternatively a large number of populations could be monitored in short periods of time using the visual count technique (Fagerstone and Biggins 1986, Knowles 1986). However, the accuracy of visual counts has only been evaluated in a few locations. Thus, it is not known whether the relationship between counts and prairie dog density is consistent throughout the prairie dog's range. Our objective was to evaluate the potential of using visual counts as a rapid means of estimating white-tailed prairie dog density in prairie dog towns throughout Wyoming. We studied 18 white-tailed prairie dog towns in 4 white-tailed prairie dog complexes in Wyoming near Laramie (105°40'W, 41°20'N, 3 grids), Pathfinder reservoir (106°55'W, 42°30'N, 6 grids), Shirley Basin (106°10'W, 42°20'N, 6 grids), and Meeteetse (108°10'W, 44°10'N, 3 grids). All towns were dominated by grasses, forbs, and shrubs (details in Collins and Lichvar 1986). Topography of towns ranged from flat to gently rolling hills.
Frank R. Thompson; Monica J. Schwalbach
1995-01-01
We report results of a point count survey of breeding birds on Hoosier National Forest in Indiana. We determined sample size requirements to detect differences in means and the effects of count duration and plot size on individual detection rates. Sample size requirements ranged from 100 to >1000 points with Type I and II error rates of <0.1 and 0.2. Sample...
A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi
2010-04-01
The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.
Sustainable Seas Intertidal Monitoring Project at Duxbury Reef
NASA Astrophysics Data System (ADS)
Soave, K. S.; Dean, A.; Gusman, V.; McCracken, K.; Solli, S.; Storm, E.; Placeholder, P.
2007-12-01
The Sustainable Seas Student Monitoring Project at the Branson School in Ross, CA has monitored Duxbury Reef in Bolinas, CA since 1999, in cooperation with the Farallones Marine Sanctuary Association and the Gulf of Farallones National Marine Sanctuary. Goals of the project include: 1) To monitor the rocky intertidal habitat and develop a baseline database of invertebrates and algal density and abundance; 2) To contribute to the conservation of the rocky intertidal habitat through education of students and visitors about intertidal species and requirements for maintaining a healthy, diverse intertidal ecosystem; 3) To increase stewardship in the Gulf of the Farallones National Marine Sanctuary; and 4) To contribute abundance and population data on key algae and invertebrate species to the national database, LiMPETS (Long Term Monitoring Program & Experiential Training for Students). Student volunteers complete an intensive training course on the natural history of intertidal invertebrates and algae, identification of key species, rocky intertidal ecology, interpretation and monitoring techniques, and history of the sanctuary. Students conduct two baseline-monitoring surveys three times per year (fall, winter, and late spring) to identify and count key invertebrate and algae species. Seasonal abundance of the algae species Mastocarpus and Fucus revealed lower populations in the spring monitoring events. Turban snails, Tegula funebralis, also showed dramatic population variation with respect to tidal zone. One of our project goals is to monitor this area long enough to obtain trends and to begin to connect these patterns to contributing factors (specific weather events, anthropogenic impacts, etc). Replicate counts of all species are regularly performed. Replicate counts for invertebrate and algae species within the same quadrat along the permanent transects revealed a very small amount of variability, giving us confidence that our monitoring program is providing reliable data. The Branson School 39 Fernhill Rd. Ross, CA 94957 (415) 454-3612 x 323 Farallones Marine Sanctuary Association, PO Box 29386 San Francisco, CA 94129, 415-561-6625 x 303
Ikomey, G; Assoumou, M-C Okomo; Atashili, J; Mesembe, M; Mukwele, B; Lyonga, E; Eyoh, A; Kafando, A; Ndumbe, P M
2016-09-01
Difficulties in systematically monitoring HIV viral load in resource-limited settings prompt the search for alternate approaches. The authors aimed at assessing the correlation between the plasma levels of soluble forms of Fas receptors (Fas) and Fas ligands (FasL) with standard indicators of HIV disease progression in children. Twenty-two HIV-1-positive children were enrolled in Yaounde. CD4 counts, CD4% counts, plasma levels of Fas, FasL, and HIV-1 RNA levels were assayed. The correlation coefficients (P values) between FasL levels and each of HIV-1 viral load, CD4 counts, and CD4% were, respectively, .56 (.01), -.29 (.18), and .30 (.18). On the other hand, the respective correlation coefficients (P values) with Fas levels were .12 (.60), -.30 (.18), and -.29 (.19). The significant correlation between levels of HIV-1 viral load and FasL suggests that the latter needs to be further studied as a potential biomarker to monitor HIV-1 disease progression in children in resource-limited setting. © The Author(s) 2013.
An overview of a landbird monitoring program at Tortuguero, on the Caribbean coast of Costa Rica
C. John Ralph; Margaret J. Widdowson; Robert I. Frey; Pablo A. Herrera; Brian P. O' Donnell
2005-01-01
Since 1994, the Tortuguero Integrated Bird Monitoring Program has been monitoring birds in a coastal lowland rain forest of northeast Costa Rica. The Program has combined the use of area searches, constanteffort mist netting, and migration counts into a longterm landbird monitoring and training program following the recommendations of the Partners In Flight &ndash...
Comparison of line transects and point counts for monitoring spring migration in forested wetlands
Wilson, R.R.; Twedt, D.J.; Elliott, A.B.
2000-01-01
We compared the efficacy of 400-m line transects and sets of three point counts at detecting avian richness and abundance in bottomland hardwood forests and intensively managed cottonwood (Populus deltoides) plantations within the Mississippi Alluvial Valley. We detected more species and more individuals on line transects than on three point counts during 218 paired surveys conducted between 24 March and 3 June, 1996 and 1997. Line transects also yielded more birds per unit of time, even though point counts yielded higher estimates of relative bird density. In structurally more-complex bottomland hardwood forests, we detected more species and individuals on line transects, but in more-open cottonwood plantations, transects surpassed point counts only at detecting species within 50 m of the observer. Species richness and total abundance of Nearctic-Neotropical migrants and temperate migrants were greater on line transects within bottomland hardwood forests. Within cottonwood plantations, however, only species richness of Nearctic-Neotropical migrants and total abundance of temperate migrants were greater on line transects. Because we compared survey techniques using the same observer, within the same forest stand on a given day, we assumed that the technique yielding greater estimates of avian species richness and total abundance per unit of effort is superior. Thus, for monitoring migration within hardwood forests of the Mississippi Alluvial Valley, we recommend using line transects instead of point counts.
Eric T. Linder; David A. Buehler
2005-01-01
In 1996, Region 8 of the U. S. Forest Service implemented a program to monitor landbirds on southeastern U.S. national forests. The goal was to develop a monitoring system that could document population trends and bird-habitat relationships. Using power analysis, we examined the ability of the monitoring program to detect population trends (3 percent annual change) at...
2011-01-01
Background It is unclear whether antiretroviral (ART) naive HIV-positive individuals with high CD4 counts have a raised mortality risk compared with the general population, but this is relevant for considering earlier initiation of antiretroviral therapy. Methods Pooling data from 23 European and North American cohorts, we calculated country-, age-, sex-, and year-standardised mortality ratios (SMRs), stratifying by risk group. Included patients had at least one pre-ART CD4 count above 350 cells/mm3. The association between CD4 count and death rate was evaluated using Poisson regression methods. Findings Of 40,830 patients contributing 80,682 person-years of follow up with CD4 count above 350 cells/mm3, 419 (1.0%) died. The SMRs (95% confidence interval) were 1.30 (1.06-1.58) in homosexual men, and 2.94 (2.28-3.73) and 9.37 (8.13-10.75) in the heterosexual and IDU risk groups respectively. CD4 count above 500 cells/mm3 was associated with a lower death rate than 350-499 cells/mm3: adjusted rate ratios (95% confidence intervals) for 500-699 cells/mm3 and above 700 cells/mm3 were 0.77 (0.61-0.95) and 0.66 (0.52-0.85) respectively. Interpretation In HIV-infected ART-naive patients with high CD4 counts, death rates were raised compared with the general population. In homosexual men this was modest, suggesting that a proportion of the increased risk in other groups is due to confounding by other factors. Even in this high CD4 count range, lower CD4 count was associated with raised mortality. PMID:20638118
Evaluation of a model community-wide bed bug management program in affordable housing.
Cooper, Richard A; Wang, Changlu; Singh, Narinderpal
2016-01-01
Low-income apartment communities in the United States are suffering from disproportionally high bed bug, Cimex lectularius L., infestations owing to lack of effective monitoring and treatment. Studies examining the effectiveness of integrated pest management (IPM) for the control of bed bugs in affordable housing have been limited to small subsets of bed-bug-infested apartments, rather than at the apartment community level. We developed, implemented and evaluated a complex-wide IPM program for bed bugs in an affordable housing community. Proactive inspections and biweekly treatments using a combination of non-chemical and chemical methods until bed bugs were not detected for three biweekly monitoring visits were key elements of the IPM program. A total of 55 bed-bug-infested apartments were identified during the initial inspection. Property management was unaware of 71% of these infestations. Over the next 12 months, 14 additional infested apartments were identified. The IPM program resulted in a 98% reduction in bed bug counts among treated apartments and reduced infestation rates from 15 to 2.2% after 12 months. Adopting a complex-wide bed bug IPM program, incorporating proactive monitoring, and biweekly treatments of infested apartments utilizing non-chemical and chemical methods can successfully reduce infestation rates to very low levels. © 2015 Society of Chemical Industry.
A Prescription for List-Mode Data Processing Conventions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beddingfield, David H.; Swinhoe, Martyn Thomas; Huszti, Jozsef
There are a variety of algorithmic approaches available to process list-mode pulse streams to produce multiplicity histograms for subsequent analysis. In the development of the INCC v6.0 code to include the processing of this data format, we have noted inconsistencies in the “processed time” between the various approaches. The processed time, tp, is the time interval over which the recorded pulses are analyzed to construct multiplicity histograms. This is the time interval that is used to convert measured counts into count rates. The observed inconsistencies in tp impact the reported count rate information and the determination of the error-values associatedmore » with the derived singles, doubles, and triples counting rates. This issue is particularly important in low count-rate environments. In this report we will present a prescription for the processing of list-mode counting data that produces values that are both correct and consistent with traditional shift-register technologies. It is our objective to define conventions for list mode data processing to ensure that the results are physically valid and numerically aligned with the results from shift-register electronics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurz, Christopher, E-mail: Christopher.Kurz@physik.uni-muenchen.de; Bauer, Julia; Conti, Maurizio
Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small numbermore » of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.« less
Modelling of aircrew radiation exposure from galactic cosmic rays and solar particle events.
Takada, M; Lewis, B J; Boudreau, M; Al Anid, H; Bennett, L G I
2007-01-01
Correlations have been developed for implementation into the semi-empirical Predictive Code for Aircrew Radiation Exposure (PCAIRE) to account for effects of extremum conditions of solar modulation and low altitude based on transport code calculations. An improved solar modulation model, as proposed by NASA, has been further adopted to interpolate between the bounding correlations for solar modulation. The conversion ratio of effective dose to ambient dose equivalent, as applied to the PCAIRE calculation (based on measurements) for the legal regulation of aircrew exposure, was re-evaluated in this work to take into consideration new ICRP-92 radiation-weighting factors and different possible irradiation geometries of the source cosmic-radiation field. A computational analysis with Monte Carlo N-Particle eXtended Code was further used to estimate additional aircrew exposure that may result from sporadic solar energetic particle events considering real-time monitoring by the Geosynchronous Operational Environmental Satellite. These predictions were compared with the ambient dose equivalent rates measured on-board an aircraft and to count rate data observed at various ground-level neutron monitors.
Role of banding in forest conservation strategy in eastern Guatemala
Robbins, C.S.; Dowell, B.A.; Arias, I.; Cerezo B., A.
1999-01-01
In response to a request from FUNDAECO, a Guatemalan non-government organization, we worked with them to develop a conservation strategy for the Cerro San Gil Protected Area and surrounding private lands. Volunteer banders from a dozen states and Canadian provinces assisted in long-term monitoring of populations of resident and migratory species through banding and point counts. Guatemalan students were trained to continue the research and initiate other conservation projects. Banding data helped demonstrate habitat and elevational affiliations, effects of habitat fragmentation, site fidelity, survival rates, local movements, and presence of rare species not otherwise detected. Banding was also an excellent teaching tool and provided videos for conservation programs on Guatemala national television. Roadside and off-road Breeding Bird Survey transects were used to map distribution of breeding species on habitat maps derived from satellite imagery, and point count surveys on private lands were used to identify prime habitats that warrant protection through conservation easements--a new concept for Central America.
NASA Astrophysics Data System (ADS)
ui, Hirotaka; Moriuchi, Hiroyuki; Takemura, Yukiko; Tsuchida, Hiroko; Fujii, Iwao; Nakamura, Masaru
1988-09-01
Radon alpha tracks monitored at six sites increased gradually three months before (detected by microscopic counting), and increased remarkably 2 weeks before (detected by both mechanical and microscopic counting) the western Nagano Prefecture earthquake ( M 6.8) which occurred on September 14, 1984. The monitoring sites were located about 65 km northwest of the epicenter, on the shear zone of the Atotsugawa fault. The changes in radon emanation are considered to be related to the earthquake rather than to changes in meteorological conditions.
Extraction of breathing pattern using temperature sensor based on Arduino board
NASA Astrophysics Data System (ADS)
Patel, Rajesh; Sengottuvel, S.; Gireesan, K.; Janawadkar, M. P.; Radhakrishnan, T. S.
2015-06-01
Most of the basic functions of human body are assessed by measuring the different parameters from the body such as temperature, pulse activity and blood pressure etc. Respiration rate is the number of inhalations a person takes per minute and needs to be quantitatively assessed as it modulates other measurements such as SQUID based magnetocardiography (MCG) by bringing the chest closer to or away from the sensor array located inside a stationary liquid helium cryostat. The respiration rate is usually measured when a person is at rest and simply involves counting the number of inhalations for one minute. This paper aims at the development of a suitable methodology for the measurement of respiration rate with the help of a temperature sensor which monitors the very slight change in temperature near the nostril during inhalation & exhalation. The design and development of the proposed system is presented, along with typical experiment results.
Response and adaptation of Beagle dogs to hypergravity
NASA Technical Reports Server (NTRS)
Oyama, J.
1975-01-01
Eight male Beagle dogs, five months old, were centrifuged continuously for three months at progressively increasing loads. Heart rate and deep body temperature were monitored continuously by implant biotelemetry. Initially, centrifuged dogs showed transient decreases in heart rate and body temperature along with changes in their diurnal rhythm patterns. Compared with normal gravity controls, exposed dogs showed a slower growth rate and a reduced amount of body fat. Blood protein, total lipids, cholesterol, calcium, packed cell volume, red blood cell count, and hemoglobin were also decreased significantly. Absolute weights of the leg bones of centrifuged dogs were significantly greater than controls. Photon absorptiometry revealed significant density increases in selective regions of the femur and humerus of centrifuged dogs. In spite of the various changes noted, results from this and other studies affirm the view that dogs can tolerate and adapt to sustained loads as high as 2.5 g without serious impairment of their body structure and function.
Generating Discrete Power-Law Distributions from a Death- Multiple Immigration Population Process
NASA Astrophysics Data System (ADS)
Matthews, J. O.; Jakeman, E.; Hopcraft, K. I.
2003-04-01
We consider the evolution of a simple population process governed by deaths and multiple immigrations that arrive with rates particular to their order. For a particular choice of rates, the equilibrium solution has a discrete power-law form. The model is a generalization of a process investigated previously where immigrants arrived in pairs [1]. The general properties of this model are discussed in a companion paper. The population is initiated with precisely M individuals present and evolves to an equilibrium distribution with a power-law tail. However the power-law tails of the equilibrium distribution are established immediately, so that moments and correlation properties of the population are undefined for any non-zero time. The technique we develop to characterize this process utilizes external monitoring that counts the emigrants leaving the population in specified time intervals. This counting distribution also possesses a power-law tail for all sampling times and the resulting time series exhibits two features worthy of note, a large variation in the strength of the signal, reflecting the power-law PDF; and secondly, intermittency of the emissions. We show that counting with a detector of finite dynamic range regularizes naturally the fluctuations, in effect `clipping' the events. All previously undefined characteristics such as the mean, autocorrelation and probabilities to the first event and time between events are well defined and derived. These properties, although obtained by discarding much data, nevertheless possess embedded power-law regimes that characterize the population in a way that is analogous to box averaging determination of fractal-dimension.
2011-01-01
Background Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Methods Pregnant women (n = 58) with body mass index ≥25 kg/m2 at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Results Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Conclusions Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women. PMID:21703033
Status of the NIST Penning-Trap Neutron Lifetime Measurement
NASA Astrophysics Data System (ADS)
Snow, W. M.; Fei, X.; Chowdhuri, Z.; Dewey, M. S.; Gilliam, D.; Nico, J. S.; Greene, G. L.
1998-10-01
The decay rate of the free neutron is important input for Big-Bang Nucleosynthesis calculations of the primordial ^4He abundance in the universe(T. P. Walker et al, Astrophys. J. 376, 51 (1991).) and for tests of the electroweak model in the charged-current sector(I. S. Towner, Nucl. Phys. A540, 478 (1992).). We will describe an experiment in progress at NIST to measure the neutron decay rate. The technique uses a Penning trap to trap and count protons from in-beam neutron decay(J. Byrne et al., Phys. Rev. Lett. 65, 289 (1990).) and an absolutely calibrated beam monitor to measure the neutron density in the beam(R. D. Scott et al., Nucl. Inst. Meth. A362, 151 (1995).). We will present data taken in the spring and summer of 1998.
The Fermilab Isdn Pilot Project: Experiences and Future Plans
NASA Astrophysics Data System (ADS)
Martin, D. E.; Lego, A. J.; Clifford, A. E.
Fully operational in June of 1994, the Fermilab ISDN Pilot Project was started to gain insight into the costs and benefits of providing ISDN service to the homes of Fermilab researchers. Fourteen users were chosen from throughout Fermilab, but the number of Fermilab-employed spouses pushed the total user count to 20. Each home was equipped with a basic rate ISDN (BRI) line, a BRI Ethernet half-bridge, and an NT-1. An inter-departmental team coordinated the project. Usage at each home was tracked and frequent surveys were attempted. Lessons learned include: working with Ameritech can be difficult; careful monitoring is essential; and configuration of home computing equipment is very time consuming. Plans include moving entirely to primary rate ISDN hubs, support for different home ISDN equipment and better usage and performance tracking.
Modeling of displacement damage in silicon carbide detectors resulting from neutron irradiation
NASA Astrophysics Data System (ADS)
Khorsandi, Behrooz
There is considerable interest in developing a power monitor system for Generation IV reactors (for instance GT-MHR). A new type of semiconductor radiation detector is under development based on silicon carbide (SiC) technology for these reactors. SiC has been selected as the semiconductor material due to its superior thermal-electrical-neutronic properties. Compared to Si, SiC is a radiation hard material; however, like Si, the properties of SiC are changed by irradiation by a large fluence of energetic neutrons, as a consequence of displacement damage, and that irradiation decreases the life-time of detectors. Predictions of displacement damage and the concomitant radiation effects are important for deciding where the SiC detectors should be placed. The purpose of this dissertation is to develop computer simulation methods to estimate the number of various defects created in SiC detectors, because of neutron irradiation, and predict at what positions of a reactor, SiC detectors could monitor the neutron flux with high reliability. The simulation modeling includes several well-known---and commercial---codes (MCNP5, TRIM, MARLOWE and VASP), and two kinetic Monte Carlo codes written by the author (MCASIC and DCRSIC). My dissertation will highlight the displacement damage that may happen in SiC detectors located in available positions in the OSURR, GT-MHR and IRIS. As extra modeling output data, the count rates of SiC for the specified locations are calculated. A conclusion of this thesis is SiC detectors that are placed in the thermal neutron region of a graphite moderator-reflector reactor have a chance to survive at least one reactor refueling cycle, while their count rates are acceptably high.
Hommel, Kevin A; Hente, Elizabeth A; Odell, Shannon; Herzer, Michele; Ingerski, Lisa M; Guilfoyle, Shanna M; Denson, Lee A
2012-01-01
To pilot test the feasibility and acceptability of a family-based group behavioral intervention and to improve medication adherence in adolescents diagnosed with inflammatory bowel disease. Participants were 40 adolescents aged 11-18 years diagnosed with inflammatory bowel disease and their primary caregivers, who were randomized to either a four-session Family-Based Group Behavioral Treatment or Usual Care over a 6-week period. Adherence was measured using a multi-method, multi-informant assessment involving caregiver-report and patient-report, pill count data, and electronic monitoring. Adherence rates ranged from 66 to 89% for 6-mercaptopurine/azathioprine and 51 to 93% for mesalamine across assessment methods. The intervention was feasible, as evidenced by the 99% treatment session attendance rate, and acceptable based on patient and caregiver report. Repeated measures analysis of variance tests revealed nonsignificant differences between the conditions from baseline to post-treatment assessments for pill count, electronic monitor, and primary caregiver-reported adherence (P's>0.05). There was a statistically significant improvement in patient-reported mesalamine adherence represented by a significant main effect for Condition (F=22.24, P<0.01; δ=0.79) and Condition×Time interaction (F=13.32, P<0.05; δ=0.69). Findings suggest potential for use of behavioral intervention to improve medication adherence in this population. This intervention may be more effective with more complex regimens (e.g. multiple doses per day) such as those prescribed with mesalamine. Further research is needed to examine this type of intervention in more diverse samples with more active disease. Use of alternative adherence measurement approaches, including electronic pill boxes and/or real-time self-report (e.g. by text messaging, electronic diaries, etc.) is also recommended.
Botzenhardt, Sebastian; Sing, Chor W; Wong, Ian C K; Chan, Godfrey Chi-Fung; Wong, Lisa Y L; Felisi, Mariagrazia; Rascher, Wolfgang; Ceci, Adriana; Neubert, Antje
2016-01-01
There is a lack of knowledge regarding the incidence of serious adverse drug reactions (ADR) to the oral iron chelator deferiprone in Chinese children with transfusion-dependent thalassaemia. In this retrospective population-based cohort study, paediatric thalassaemia patients in Hong Kong were screened for serious and medically important adverse events related to deferiprone therapy using diagnosis codes, laboratory data and hospital admissions. Potential ADRs were assessed by reviewing concomitant medications, diagnoses and laboratory data and evaluated using standardised causality assessment. Eighty-seven patients contributing 169.8 person-years were included. Thirty ADRs were identified in 21 patients. Most ADRs (56.0%) occurred in the first three months of therapy. Neutropenia occurred in 11 patients (12.6%; incidence rate 6.5 per 100 patient-years) and severe neutropenia (agranulocytosis) was observed in 5 patients (5.7%, incidence rate 2.9 per 100 patient-years). Other identified ADRs involve severe arthropathy, elevated liver enzymes and mild thrombocytopenia. In conclusion, the safety profile of DFP therapy in Chinese children suffering from transfusion-dependent thalassaemia is in line with previous studies of non-Chinese children. However, unlike previous studies, we observed a relatively high incidence of agranulocytosis and neutropenia in patients with simultaneous combined therapy. Hence close monitoring for white blood cell counts is advised in Chinese children under combined iron chelation therapy. Further prospective clinical and pharmacogenetic studies are required to better evaluate this important safety signal. • Half of the identified ADRs related to deferiprone therapy occurred during the first three months of treatment. • A relatively high incidence of agranulocytosis and neutropenia. Hence close monitoring for white blood cell counts is advised in Chinese children under combined iron chelation therapy.
Onsets of Solar Proton Events in Satellite and Ground Level Observations: A Comparison
NASA Astrophysics Data System (ADS)
He, Jing; Rodriguez, Juan V.
2018-03-01
The early detection of solar proton event onsets is essential for protecting humans and electronics in space, as well as passengers and crew at aviation altitudes. Two commonly compared methods for observing solar proton events that are sufficiently large and energetic to be detected on the ground through the creation of secondary radiation—known as ground level enhancements (GLEs)—are (1) a network of ground-based neutron monitors (NMs) and (2) satellite-based particle detectors. Until recently, owing to the different time resolution of the two data sets, it has not been feasible to compare these two types of observations using the same detection algorithm. This paper presents a comparison between the two observational platforms using newly processed >100 MeV 1 min count rates and fluxes from National Oceanic and Atmospheric Administration's Geostationary Operational Environmental Satellite (GOES) 8-12 satellites, and 1 min count rates from the Neutron Monitor Database. We applied the same detection algorithm to each data set (tuned to the different background noise levels of the instrument types). Seventeen SPEs with GLEs were studied: GLEs 55-70 from Solar Cycle 23 and GLE 71 from Solar Cycle 24. The median difference in the event detection times by GOES and NM data is 0 min, indicating no innate benefit in time of either system. The 10th, 25th, 75th, and 90th percentiles of the onset time differences (GOES minus NMs) are -7.2 min, -1.5 min, 2.5 min, and 4.2 min, respectively. This is in contrast to previous studies in which NM detections led GOES by 8 to 52 min without accounting for different alert protocols.
Estimating wind-turbine-caused bird and bat fatality when zero carcasses are observed.
Huso, Manuela M P; Dalthorp, Dan; Dail, David; Madsen, Lisa
2015-07-01
Many wind-power facilities in the United States have established effective monitoring programs to determine turbine-caused fatality rates of birds and bats, but estimating the number of fatalities of rare species poses special difficulties. The loss of even small numbers of individuals may adversely affect fragile populations, but typically, few (if any) carcasses are observed during monitoring. If monitoring design results in only a small proportion of carcasses detected, then finding zero carcasses may give little assurance that the number of actual fatalities is small. Fatality monitoring at wind-power facilities commonly involves conducting experiments to estimate the probability (g) an individual will be observed, accounting for the possibilities that it falls in an unsearched area, is scavenged prior to detection, or remains undetected even when present. When g < 1, the total carcass count (X) underestimates the total number of fatalities (M). Total counts can be 0 when M is small or when M is large and g < 1. Distinguishing these two cases is critical when estimating fatality of a rare species. Observing no individuals during searches may erroneously be interpreted as evidence of absence. We present an approach that uses Bayes' theorem to construct a posterior distribution for M, i.e., P(M \\ X, ĝ), reflecting the observed carcass count and previously estimated g. From this distribution, we calculate two values important to conservation: the probability that M is below a predetermined limit and the upper bound (M*) of the 100(1 - α)% credible interval for M. We investigate the dependence of M* on α, g, and the prior distribution of M, asking what value of g is required to attain a desired M for a given α. We found that when g < -0.15, M* was clearly influenced by the mean and variance of ĝ and the choice of prior distribution for M, but the influence of these factors is minimal when g > -0.45. Further, we develop extensions for temporal replication that can inform prior distributions of M and methods for combining information across several areas or time periods. We apply the method to data collected at a wind-power facility where scheduled searches yielded X = 0 raptor carcasses.
Statistical aspects of point count sampling
Barker, R.J.; Sauer, J.R.; Ralph, C.J.; Sauer, J.R.; Droege, S.
1995-01-01
The dominant feature of point counts is that they do not census birds, but instead provide incomplete counts of individuals present within a survey plot. Considering a simple model for point count sampling, we demon-strate that use of these incomplete counts can bias estimators and testing procedures, leading to inappropriate conclusions. A large portion of the variability in point counts is caused by the incomplete counting, and this within-count variation can be confounded with ecologically meaningful varia-tion. We recommend caution in the analysis of estimates obtained from point counts. Using; our model, we also consider optimal allocation of sampling effort. The critical step in the optimization process is in determining the goals of the study and methods that will be used to meet these goals. By explicitly defining the constraints on sampling and by estimating the relationship between precision and bias of estimators and time spent counting, we can predict the optimal time at a point for each of several monitoring goals. In general, time spent at a point will differ depending on the goals of the study.
Differences in alarm events between disposable and reusable electrocardiography lead wires.
Albert, Nancy M; Murray, Terri; Bena, James F; Slifcak, Ellen; Roach, Joel D; Spence, Jackie; Burkle, Alicia
2015-01-01
Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. To examine differences in alarm events between disposable and reusable ECG-LWs. Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety. ©2015 American Association of Critical-Care Nurses.
Normal CD4 Count Range among Healthy Nigerian Population in Ilorin.
Afolabi, J K; Fadeyi, A; Desalu, O O; Durotoye, I A; Fawibe, A E; Adeboye, M A N; Olawumi, H O; Babatunde, A S; Ernest, S K; Aderibigbe, S A; Saadu, R; Salami, A K; Aboyeji, A P
For the establishment and monitoring of the immune status, CD4 count is critical. To determine the CD4 count range of apparently healthy Nigerians resident in Ilorin and compare with the national value. An automated blood analyzer was used to determine the full blood count and CD4 count. The percentage of CD4 count was derived by using other variables. Of the 1205 participants, the reference CD4 count (percentage of CD4) range for adult was 400 to 1288 cells/mm 3 (19%-48%) and for children was 582 to 3652 cells/mm 3 (17%-50%). CD4 count and percentage of CD4 were significantly ( P = .001) higher in females than in males, and the CD4 count declined significantly with increasing age ( r = -.174, P ≤ .0001). The percentage of CD4 count shows less variation with age ( r = -.051, P = .076). Adult residents of Ilorin had significantly lower absolute mean CD4 count (808 ± 260) than that of the national reference values of 847.0 ± 307.0 cells/mm 3 ( P = .001). We therefore advocate the use of CD4 count range derived in this study is lower than that of the national reference values.
ERIC Educational Resources Information Center
Temple, Viviene A.; Stanish, Heidi I.
2009-01-01
Pedometers are objective, inexpensive, valid, and reliable measures of physical activity. The minimum number of days of pedometer monitoring needed to estimate average weekly step counts was investigated. Seven days of pedometer data were collected from 154 ambulatory men and women ("ns" = 88 and 66, respectively) with intellectual disability.…
Precise, unbiased estimates of population size are an essential tool for fisheries management. For a wide variety of salmonid fishes, redd counts from a sample of reaches are commonly used to monitor annual trends in abundance. Using a 9-year time series of georeferenced censuses...
Further Development of Measures of Early Math Performance for Preschoolers
ERIC Educational Resources Information Center
VanDerHeyden, Amanda M.; Broussard, Carmen; Cooley, Amanda
2006-01-01
The purpose of this study was to examine the progress monitoring and screening accuracy for a set of curriculum-based measures (CBM) of early mathematics skills. Measures included counting objects, selecting numbers, naming numbers, counting, and visual discrimination. Measures were designed to be administered with preschoolers in a short period…
THE USE OF QUENCHING IN A LIQUID SCINTILLATION COUNTER FOR QUANTITATIVE ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foster, G.V.
1963-01-01
Quenching was used to quantitatively determine the amonnt of quenching agent present. A sealed promethium147 source was prepared to be used for the count rate determinations. Two methods to determine the amount of quenching agent present in a sample were developed. One method related the count rate of a sample containing a quenching agent to the amount of quenching agent present. Calibration curves were plotted using both color and chemical quenchers. The quenching agents used were: F.D.C. Orange No. 2, F.D.C. Yellow No. 3, F.D.C. Yellow No. 4, Scarlet Red, acetone, benzaldehyde, and carbon tetrachloride. the color quenchers gave amore » linear-relationship, while the chemical quenchers gave a non-linear relationship. Quantities of the color quenchers between about 0.008 mg and 0.100 mg can be determined with an error less than 5%. The calibration curves were found to be usable over a long period of time. The other method related the change in the ratio of the count rates in two voltage windows to the amount of quenching agent present. The quenchers mentioned above were used. Calibration curves were plotted for both the color and chemical quenchers. The relationships of ratio versus amount of quencher were non-linear in each case. It was shown that the reproducibility of the count rate and the ratio was independent of the amount of quencher present but was dependent on the count rate. At count rates above 10,000 counts per minute the reproducibility was better than 1%. (TCO)« less
Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions
NASA Astrophysics Data System (ADS)
Kolthammer, Jeffrey A.; Su, Kuan-Hao; Grover, Anu; Narayanan, Manoj; Jordan, David W.; Muzic, Raymond F.
2014-07-01
This study evaluated the positron emission tomography (PET) imaging performance of the Ingenuity TF 128 PET/computed tomography (CT) scanner which has a PET component that was designed to support a wider radioactivity range than is possible with those of Gemini TF PET/CT and Ingenuity TF PET/MR. Spatial resolution, sensitivity, count rate characteristics and image quality were evaluated according to the NEMA NU 2-2007 standard and ACR phantom accreditation procedures; these were supplemented by additional measurements intended to characterize the system under conditions that would be encountered during quantitative cardiac imaging with 82Rb. Image quality was evaluated using a hot spheres phantom, and various contrast recovery and noise measurements were made from replicated images. Timing and energy resolution, dead time, and the linearity of the image activity concentration, were all measured over a wide range of count rates. Spatial resolution (4.8-5.1 mm FWHM), sensitivity (7.3 cps kBq-1), peak noise-equivalent count rate (124 kcps), and peak trues rate (365 kcps) were similar to those of the Gemini TF PET/CT. Contrast recovery was higher with a 2 mm, body-detail reconstruction than with a 4 mm, body reconstruction, although the precision was reduced. The noise equivalent count rate peak was broad (within 10% of peak from 241-609 MBq). The activity measured in phantom images was within 10% of the true activity for count rates up to those observed in 82Rb cardiac PET studies.
Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.
2014-01-01
Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213
Background Conditions for the October 29, 2003 Solar Flare by the AVS-F Apparatus Data
NASA Astrophysics Data System (ADS)
Arkhangelskaja, I. V.; Arkhangelskiy, A. I.; Lyapin, A. R.; Troitskaya, E. V.
The background model for AVS-F apparatus onboard CORONAS-F satellite for the October 29, 2003 X10-class solar flare is discussed in the presented work. This background model developed for AVS-F counts rate in the low- and high-energy spectral ranges in both individual channels and summarized. Count rate were approximated by polynomials of high order taking into account the mean count rate in the geomagnetic equatorial region at the different orbits parts and Kp-index averaged on 5 bins in time interval from -24 to -12 hours before the time of geomagnetic equator passing. The observed averaged counts rate on equator in the region of geomagnetic latitude ±5o and estimated minimum count rate values are in coincidence within statistical errors for all selected orbits parts used for background modeling. This model will used to refine the estimated energy of registered during the solar flare spectral features and detailed analysis of their temporal profiles behavior both in corresponding energy bands and in summarized energy range.
Extreme Ultraviolet Explorer observations of the magnetic cataclysmic variable RE 1938-461
NASA Technical Reports Server (NTRS)
Warren, John K.; Vallerga, John V.; Mauche, Christopher W.; Mukai, Koji; Siegmund, Oswald H. W.
1993-01-01
The magnetic cataclysmic variable RE 1938-461 was observed by the Extreme Ultraviolet Explorer (EUVE) Deep Survey instrument on 1992 July 8-9 during in-orbit calibration. It was detected in the Lexan/ boron (65-190 A) band, with a quiescent count rate of 0.0062 +/- 0.0017/s, and was not detected in the aluminum/carbon (160-360 A) band. The Lexan/boron count rate is lower than the corresponding ROSAT wide-field camera Lexan/boron count rate. This is consistent with the fact that the source was in a low state during an optical observation performed just after the EUVE observation, whereas it was in an optical high state during the ROSAT observation. The quiescent count rates are consistent with a virtual cessation of accretion. Two transient events lasting about 1 hr occurred during the Lexan/boron pointing, the second at a count rate of 0.050 +/- 0.006/s. This appears to be the first detection of an EUV transient during the low state of a magnetic cataclysmic variable. We propose two possible explanations for the transient events.
Rakitzis, Athanasios C; Castagliola, Philippe; Maravelakis, Petros E
2018-02-01
In this work, we study upper-sided cumulative sum control charts that are suitable for monitoring geometrically inflated Poisson processes. We assume that a process is properly described by a two-parameter extension of the zero-inflated Poisson distribution, which can be used for modeling count data with an excessive number of zero and non-zero values. Two different upper-sided cumulative sum-type schemes are considered, both suitable for the detection of increasing shifts in the average of the process. Aspects of their statistical design are discussed and their performance is compared under various out-of-control situations. Changes in both parameters of the process are considered. Finally, the monitoring of the monthly cases of poliomyelitis in the USA is given as an illustrative example.
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
Mount Rainier National Park and Olympic National Park Elk Monitoring Program Annual Report 2010
Griffin, Paul; Happe, Patricia J.; Jenkins, Kurt J.; Reid, Mason; Vales, David J.; Moeller, Barbara J.; Tirhi, Michelle; McCorquodale, Scott; Miller, Pat
2010-01-01
Fiscal year 2010 was the third year of gathering data needed for protocol development while simultaneously implementing what is expected to be the elk monitoring protocol at Mount Rainier (MORA) and Olympic (OLYM) national parks in the North Coast and Cascades Network (NCCN). Elk monitoring in these large wilderness parks relies on aerial surveys from a helicopter. Summer surveys are planned for both parks and are intended to provide quantitative estimates of abundance, sex and age composition, and distribution of migratory elk in high elevation trend count areas. Spring surveys are planned at Olympic National Park and are intended to provide quantitative estimates of abundance of resident and migratory elk on low-elevation winter ranges within surveyed trend count areas. An unknown number of elk is not detected during surveys. The protocol under development aims to estimate the number of missed elk by applying a model that accounts for detection bias. Detection bias in elk surveys in MORA will be estimated using a double-observer sightability model that was developed based on data from surveys conducted in 2008-2010. The model was developed using elk that were previously equipped with radio collars by cooperating tribes. That model is currently in peer review. At the onset of protocol development in OLYM there were no existing radio- collars on elk. Consequently double-observer sightability models have not yet been developed for elk surveys in OLYM; the majority of the effort in OLYM has been focused on capturing and radio collaring elk to permit the development of sightability models for application in OLYM. As a result, no estimates of abundance or composition are included in this annual report, only raw counts of the numbers of elk seen in surveys. At MORA each of the two trend count areas (North Rainier herd, and South Rainier herd) were surveyed twice. 290 and 380 elk were counted on the two replicates in the North Rainier herd, and 621 and 327 elk counted on the two replicate South Rainier counts. At Olympic National Park, each of three spring trend count areas was surveyed once in March 2010. 27 elk were observed in the South Fork Hoh trend count area, 137 elk were observed in the Hoh trend count area, and 131 elk were observed in the Queets trend count area. In September 2010, 18 elk were captured and fitted with radio collars as part of a contracted animal capture, eradication and tagging of animals (ACETA) operation. These animals will be available to contribute double-observer sightability data in future spring and summer surveys. There were no summer surveys for elk in OLYM in 2010.
NASA Astrophysics Data System (ADS)
Desai, Shraddha S.; Devan, Shylaja; Das, Amrita; Patkar, S. M.; Rao, Mala N.
2018-04-01
Neutron scattering instruments at Dhruva reactor are equipped with in house developed neutron beam flux monitors. Measurements of variations in intensity are essential to normalize the scattered neutron spectra against the reactor power fluctuations, energy of monochromatic beam, and various other factors. Two different beam monitor geometries are considered as per the beam size and optics. These detectors are fabricated with tailor-made designs to suit individual beam size and neutron flux. Pencil size beam monitors for integral intensity measurement are fabricated with coaxial geometry and BF3 fill gas for high n-gamma discrimination and count rate capability. Brass cathode design is modified to SS based rugged design, considering beam transmission. Coaxial beam monitor partially intercepts the collimated beam and gives relative magnitude of the flux with time. For certain experiments, size of beam varies due to use of focusing monochromator. Thus a beam monitor with square sensitive region covering entire beam is essential. Multiwire based planar detector for use in transmission mode is designed. Negligible absorption of neutron beam intensity within the detector hardware is ensured. Design of detectors is tailor made for beam geometry. Both these types of beam monitors are fabricated and characterized at G2 beam line and Triple Axis Spectrometer at Dhruva reactor. Performance of detector is suitable for the beam monitoring up to neutron flux ˜ 106 n/cm2/sec. Design aspects and performance details of these beam monitors are mentioned in the paper.
Grauer, Andreas; König, Andreas; Bunnefeld, Nils
2015-01-01
Numbers of large grazing bird (geese, swans, cranes) have increased all over Europe, but monitoring these species, e.g. for management purposes, can be time consuming and costly. In Bavaria, sedentary Greylag geese (Anser anser) are monitored during the winter by two different citizen-based monitoring schemes: the International Waterbird Census [IWC] and hunting bag statistics. We compared the results of both schemes for the seasons 1988/89 to 2010/11 by analysing annual indices calculated using the software TRends and Indices for Monitoring Data-TRIM. We identified similar, highly significant rates of increase in both data sets for the entire region of Bavaria (IWC 14% [13-15%], bag 13% [12-14%]). Furthermore, in all of the seven Bavarian regions, trends in annual indices of both data sets correlated significantly. The quality of both datasets as indicators of abundances in Greylag geese populations in Bavaria was not undermined by either weaknesses typically associated with citizen based monitoring or problems generally assumed for IWC and bag data. We also show that bag data are, under the German system of collecting bag statistics, a reliable indicator of species' distribution, especially for detecting newly colonized areas. Therefore, wildlife managers may want to consider bag data from citizen science led monitoring programmes as evidence supporting the decision making processes. We also discuss requirements for any bag monitoring schemes being established to monitor trends in species' distribution and abundance.
Legionella prevalence and risk of legionellosis in Hungarian hospitals.
Barna, Zsófia; Kádár, Mihály; Kálmán, Emese; Róka, Eszter; Szax, Anita Sch; Vargha, Márta
2015-12-01
Nosocomial legionellosis is a growing concern worldwide. In Hungary, about 20% of the reported cases are health-care associated, but in the absence of legal regulation, environmental monitoring of Legionella is not routinely performed in hospitals. In the present study, 23 hospitals were investigated. The hot water distribution system was colonized by Legionella in over 90%; counts generally exceeded the public health limit value. Hot water temperature was critically low in all systems (<45 °C), and large differences (3-38 °C temperature drop) were observed within buildings, indicating insufficient circulation. Most facilities were older than 30 years (77%); however, new systems (n = 3) were also shown to be rapidly colonized at low hot water temperature. Vulnerable source of drinking water, complex distribution system, and large volume hot water storage increased the risk of Legionella prevalence (OR = 28.0, 27.3, 27.7, respectively). Risk management interventions (including thermal or chemical disinfection) were only efficient if the system operation was optimized. Though the risk factors were similar, in those hospitals where nosocomial legionellosis was reported, Legionella counts and the proportion of L. pneumophila sg 1 isolates were significantly higher. The results of environmental prevalence of legionellae in hospitals suggest that the incidence of nosocomial legionellosis is likely to be underreported. The observed colonization rates call for the introduction of a mandatory environmental monitoring scheme.
Crater Age and Hydrogen Content in Lunar Regolith from LEND Neutron Data
NASA Astrophysics Data System (ADS)
Sanin, Anton; Starr, Richard; Litvak, Maxim; Petro, Noah; Mitrofanov, Igor
2017-04-01
We are presenting an analysis of Lunar Exploration Neutron Detector (LEND) epithermal neutron count rates for a large set of mid-latitude craters. Epithermal neutron count rates for crater interiors measured by the LEND Sensor for Epithermal Neutrons (SETN) were compared to crater exteriors for 322 craters. An increase in relative count rate at about 9-sigma confidence level was found, consistent with a lower hydrogen content. A smaller subset of 31 craters, all located near three Copernican era craters, Jackson, Tycho, and Necho, also shows a significant increase in Optical Maturity parameter implying an immature regolith. The increase in SETN count rate for these craters is greater than the increase for the full set of craters by more than a factor of two.
Crater Age and Hydrogen Content in Lunar Regolith from LEND Neutron Data
NASA Technical Reports Server (NTRS)
Starr, Richard D.; Litvak, Maxim L.; Petro, Noah E.; Mitrofanov, Igor G.; Boynton, William V.; Chin, Gordon; Livengood, Timothy A.; McClanahan, Timothy P.; Sanin, Anton B.; Sagdeev, Roald Z.;
2017-01-01
Analysis of Lunar Exploration Neutron Detector (LEND) neutron count rates for a large set of mid-latitude craters provides evidence for lower hydrogen content in the crater interiors compared to typical highland values. Epithermal neutron count rates for crater interiors measured by the LEND Sensor for Epithermal Neutrons (SETN) were compared to crater exteriors for 301 craters and displayed an increase in mean count rate at the approx. 9-sigma confidence level, consistent with a lower hydrogen content. A smaller subset of 31 craters also shows a significant increase in Optical Maturity parameter implying an immature regolith. The increase in SETN count rate for these craters is greater than the increase for the full set of craters by more than a factor of two.
Risk factors for mortality in a south Indian population on generic antiretroviral therapy.
Rupali, Priscilla; Mannam, Sam; Bella, Annie; John, Lydia; Rajkumar, S; Clarence, Peace; Pulimood, Susanne A; Samuel, Prasanna; Karthik, Rajiv; Abraham, Ooriapadickal Cherian; Mathai, Dilip
2012-12-01
Antiretroviral treatment (ART) programs from low-income countries utilizing standardized ART regimens, simplified approaches to clinical decision making and basic lab monitoring have reported high mortality rates. We determined the risk factors for mortality among HIV-infected adults following the initiation of ART from a single center in south India. ART-naive HIV-infected south Indian adults attending the Infectious Diseases clinic in a 2000-bed academic medical center in south India who were initiated on ART (generic, fixed-dose combinations) as per the national guidelines were followed up. Cases (32 patients who died) were compared with age and sex matched controls. Eight-hundred and twenty-two patients were started on ART from January 1, 2000 to December 31, 2008. The cumulative mortality was 6.8% (56/822). Among the cases mean age was 44 years, 18% were women and mean CD4 counts was 107 cells/microl. Among the controls mean age was 41 years, 18% were women and mean CD4 counts were 113 cells/microl. Stavudine based ART was predominant 62.5% in the cases vs 37.5% in the controls, followed by zidovudine based therapy in 31.2% of cases and 43.7% in the controls. Tenofovir based therapy was used in 6.2% of cases vs 18.7% in the controls. The commonest causes of death were drug toxicity 19%, advanced Acquired Immunodeficiency Syndrome (AIDS) in 37%, Immune Reconstitution Inflammatory Syndrome (IRIS) in 16%, non AIDS related deaths in 22% and malignancies 6%. In a univariate analysis, absolute lymphocyte count <1200 cells/cmm (p=0.03), development of immune reconstitution inflammatory syndrome (IRIS) (p=0.000) and mean CD4 cell count increase <75 cells/microl after 1 year of ART (p=0.001) were significantly associated with mortality. The mortality among our patients was comparable to that reported from other low-income countries. Earlier initiation of ART may reduce the high mortality rates observed.
Relationship of milking rate to somatic cell count.
Brown, C A; Rischette, S J; Schultz, L H
1986-03-01
Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.
Selecting long-term care facilities with high use of acute hospitalisations: issues and options
2014-01-01
Background This paper considers approaches to the question “Which long-term care facilities have residents with high use of acute hospitalisations?” It compares four methods of identifying long-term care facilities with high use of acute hospitalisations by demonstrating four selection methods, identifies key factors to be resolved when deciding which methods to employ, and discusses their appropriateness for different research questions. Methods OPAL was a census-type survey of aged care facilities and residents in Auckland, New Zealand, in 2008. It collected information about facility management and resident demographics, needs and care. Survey records (149 aged care facilities, 6271 residents) were linked to hospital and mortality records routinely assembled by health authorities. The main ranking endpoint was acute hospitalisations for diagnoses that were classified as potentially avoidable. Facilities were ranked using 1) simple event counts per person, 2) event rates per year of resident follow-up, 3) statistical model of rates using four predictors, and 4) change in ranks between methods 2) and 3). A generalized mixed model was used for Method 3 to handle the clustered nature of the data. Results 3048 potentially avoidable hospitalisations were observed during 22 months’ follow-up. The same “top ten” facilities were selected by Methods 1 and 2. The statistical model (Method 3), predicting rates from resident and facility characteristics, ranked facilities differently than these two simple methods. The change-in-ranks method identified a very different set of “top ten” facilities. All methods showed a continuum of use, with no clear distinction between facilities with higher use. Conclusion Choice of selection method should depend upon the purpose of selection. To monitor performance during a period of change, a recent simple rate, count per resident, or even count per bed, may suffice. To find high–use facilities regardless of resident needs, recent history of admissions is highly predictive. To target a few high-use facilities that have high rates after considering facility and resident characteristics, model residuals or a large increase in rank may be preferable. PMID:25052433
Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F
2017-04-15
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.
A CAM (continuous air monitor) sampler for collecting and assessing alpha-emitting aerosol particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFarland, A.R.; Bethel, E.L.; Ortiz, C.A.
1991-07-01
A new continuous air monitor (CAM) sampler for assessing alpha-emitting transuranic aerosol particles has been developed. The system has been designed to permit collection of particles that can potentially penetrate into the thoracic region of the human respiratory system. Wind tunnel testing of the sampler has been used to characterize the penetration of aerosol to the collection filter. Results show that greater than or equal to 50% of 10-micrograms aerodynamic equivalent diameter (AED) particles are collected by the filter at wind speeds of 0.3 to 2 m s-1 and at sampling flow rates of 28 to 113 L min-1 (1more » to 4 cfm). The deposition of 10-microns AED particles takes place primarily in the center of the filter, where the counting efficiency of the detector is highest.« less
Fast response neutron emission monitor for fusion reactor using stilbene scintillator and Flash-ADC.
Itoga, T; Ishikawa, M; Baba, M; Okuji, T; Oishi, T; Nakhostin, M; Nishitani, T
2007-01-01
The stilbene neutron detector which has been used for neutron emission profile monitoring in JT-60U has been improved, to respond to the requirement to observe the high-frequency phenomena in megahertz region such as toroidicity-induced Alfvén Eigen mode in burning plasma as well as the spatial profile and the energy spectrum. This high-frequency phenomenon is of great interest and one of the key issues in plasma physics in recent years. To achieve a fast response in the stilbene detector, a Flash-ADC is applied and the wave form of the anode signal stored directly, and neutron/gamma discrimination was carried out via software with a new scheme for data acquisition mode to extend the count rate limit to MHz region from 1.3 x 10(5) neutron/s in the past, and confirmed the adequacy of the method.
Performance evaluation of a LYSO-based PET scanner for monitoring of dose delivery in hadrontherapy
NASA Astrophysics Data System (ADS)
Fabbiani, E.; Belcari, N.; Camarlinghi, N.; Del Guerra, A.; Ferretti, S.; Kraan, A.; Panetta, D.; Sportelli, G.; Rosso, V.
2015-12-01
The DoPET scanner is a compact positron emission tomography (PET) device. It has been developed for monitoring the range of charged particles during therapy with hadron beams. Previous works have focused on the development and upgrade of the device and on data analysis. In this paper, a full performance characterization of the DoPET system in terms of the energy resolution, spatial resolution, sensitivity, uniformity, and noise equivalent count rate is reported. All measurements refer to an adapted version of the National Electrical Manufacturers Association (NEMA) NU 4 - 2008 protocol, which was written originally for small animal PET systems. Since DoPET is a dual head planar system, it requires a modified characterisation procedure with respect to those described for ring geometries as in the NEMA NU 4 - 2008 protocol. The presented procedure may be of interest for any other PET system with a similar geometry as DoPET.
Continuous Activity Monitoring During Concurrent Chemoradiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohri, Nitin, E-mail: ohri.nitin@gmail.com; Kabarriti, Rafi; Bodner, William R.
Purpose: To perform a prospective trial testing the feasibility and utility of acquiring activity data as a measure of health status during concurrent chemoradiotherapy. Methods and Materials: Ambulatory patients who were planned for treatment with concurrent chemoradiotherapy with curative intent for cancers of the head and neck, lung, or gastrointestinal tract were provided with activity monitors before treatment initiation. Patients were asked to wear the devices continuously throughout the radiation therapy course. Step count data were downloaded weekly during radiation therapy and 2 and 4 weeks after radiation therapy completion. The primary objective was to demonstrate feasibility, defined as collection ofmore » step counts for 80% of the days during study subjects' radiation therapy courses. Secondary objectives included establishing step count as a dynamic predictor of unplanned hospitalization risk. Results: Thirty-eight enrolled patients were treated with concurrent chemoradiotherapy. Primary diagnoses included head and neck cancer (n=11), lung cancer (n=13), and a variety of gastrointestinal cancers (n=14). Step data were collected for 1524 of 1613 days (94%) during patients' radiation therapy courses. Fourteen patients were hospitalized during radiation therapy or within 4 weeks of radiation therapy completion. Cox regression modeling demonstrated a significant association between recent step counts (3-day average) and hospitalization risk, with a 38% reduction in the risk of hospitalization for every 1000 steps taken each day (hazard ratio 0.62, 95% confidence interval 0.46-0.83, P=.002). Inferior quality of life scores and impaired performance status were not associated with increased hospitalization risk. Conclusion: Continuous activity monitoring during concurrent chemoradiotherapy is feasible and well-tolerated. Step counts may serve as powerful, objective, and dynamic indicators of hospitalization risk.« less
NASA Astrophysics Data System (ADS)
Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua
2016-03-01
Pixelated photon counting detectors with energy discrimination capabilities are of increasing clinical interest for x-ray imaging. Such detectors, presently in clinical use for mammography and under development for breast tomosynthesis and spectral CT, usually employ in-pixel circuits based on crystalline silicon - a semiconductor material that is generally not well-suited for economic manufacture of large-area devices. One interesting alternative semiconductor is polycrystalline silicon (poly-Si), a thin-film technology capable of creating very large-area, monolithic devices. Similar to crystalline silicon, poly-Si allows implementation of the type of fast, complex, in-pixel circuitry required for photon counting - operating at processing speeds that are not possible with amorphous silicon (the material currently used for large-area, active matrix, flat-panel imagers). The pixel circuits of two-dimensional photon counting arrays are generally comprised of four stages: amplifier, comparator, clock generator and counter. The analog front-end (in particular, the amplifier) strongly influences performance and is therefore of interest to study. In this paper, the relationship between incident and output count rate of the analog front-end is explored under diagnostic imaging conditions for a promising poly-Si based design. The input to the amplifier is modeled in the time domain assuming a realistic input x-ray spectrum. Simulations of circuits based on poly-Si thin-film transistors are used to determine the resulting output count rate as a function of input count rate, energy discrimination threshold and operating conditions.
Study of the long time-scale variability of cosmic rays with the ARGO-YBJ experiment
NASA Astrophysics Data System (ADS)
Cappa, Alba; James, Irina; Salvini, Paola
The long term modulation of the cosmic ray intensity includes both Sun and celestial anisotropies. The solar activity is due to high energy flares producing a decrease (known as Forbush Decrease, FD) in the cosmic ray intensity, with a time scale of the order of a few days, often accompained by a Ground Level Enhancement, due to direct Sun emission during the solar flare. The celestial anisotropies are due to the Earth motion in the cosmic rays reference system (solar anisotropy: Compton-Getting effect) and to the solar system location inside the Galaxy (sidereal anisotropies). These anisotropies are studied in ground-base experiments by means of EAS arrays, and the high energy solar emission is mainly studied from ground by neutron monitors. In the ARGO-YBJ experiment these phenomena are investigated by means of the "scaler mode" technique: the detector counting rates of four low multiplicity channels from singles to four-fold coincidences are recorded in a fixed time window of 0.5 s. The signal corresponds to a significant enhancement of the observed counting rate, after correcting the data for enviromental and instrumental parameters. In this paper we present the sensitivity of the ARGO-YBJ detector and the first results for both solar physics and cosmic ray anisotropy studies.
Savu, Anamaria; Schopflocher, Donald; Scholnick, Barry; Kaul, Padma
2016-01-13
We examined the association between personal bankruptcy filing and acute myocardial infarction (AMI) rates in Canada. Between 2002 and 2009, aggregate and yearly bankruptcy and AMI rates were estimated for 1,155 forward sortation areas of Canada. Scatter plot and correlations were used to assess the association of the aggregate rates. Cross-lagged structural equation models were used to explore the longitudinal relationship between bankruptcy and AMI after adjustment for socio-economic factors. A cross-lagged structural equation model estimated that on average, an increase of 100 in bankruptcy filing count is associated with an increase of 1.5 (p = 0.02) in AMI count in the following year, and an increase of 100 in AMI count is associated with an increase of 7 (p < 0.01) in bankruptcy filing count. We found that regions with higher rates of AMI corresponded to those with higher levels of economic and financial stress, as indicated by personal bankruptcy rate, and vice-versa.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Theodorakis, M.C.; Simpson, D.R.; Leung, D.M.
1983-02-01
A new method for monitoring tablet disintegration in vivo was developed. In this method, the tablets were labeled with a short-lived radionuclide, technetium 99m, and monitored by a gamma camera. Several innovations were introduced with this method. First, computer reconstruction algorithms were used to enhance the scintigraphic images of the disintegrating tablet in vivo. Second, the use of a four-pinhole collimator to acquire multiple views of the tablet resulted in high count rates and reduced acquisition times of the scintigraphic images. Third, the magnification of the scintigraphic images achieved by pinhole collimation led to significant improvement in resolution. Fourth, themore » radioinuclide was incorporated into the granulation so that the whole mass of the tablet was uniformly labeled with high levels of activity. This technique allowed the continuous monitoring of the disintegration process of tablets in vivo in experimental animals. Multiple pinhole collimation and the labeling process permitted the acquisition of quality scintigraphic images of the labeled tablet every 30 sec. The resolution of the method was tested in vitro and in vivo.« less
A Land Manager's Guide to Point Counts of Birds in the Southeast
Paul B. Hamel; Winston P. Smith; Daniel J. Twedt; James R. Woehr; Eddie Morris; Robert B. Hamilton; Robert J. Cooper
1996-01-01
Current widespread concern for the status of neotropical migratory birds has sparked interest in techniques for inventorying and monitoring populations of these and other birds in southeastern forest habitats. The present guide gives detailed instructions for conducting point counts of birds. It further presents a detailed methodology for the design and conduct of...
METHOD AND APPARATUS FOR METABOLIC ASSAY
Tolbert, B.M.; Kirk, M.R.; Baker, E.M.
1961-09-19
A method and instrumentation are described for producing an instuntuneous and continuous curve of the rate at which any selected carbon- containing substance is metabolized by a living subject. The substance is prepared with a known proportion of C/sup 14/ and, after administration, the C/ sup 14/ content of the subject's exhalations is continuously monitored along with the total C0/sub 2/ content thereof. The resulting data are continuously compared and displayed in graphical form to give the desired metabolic information. The invention includes specialized radiation counting means as well as means for assuring exact synchronization of the C/sup 14/ and C0/sub 2/ signals.
NASA Astrophysics Data System (ADS)
Englander, J. G.; Brodrick, P. G.; Brandt, A. R.
2015-12-01
Fugitive emissions from oil and gas extraction have become a greater concern with the recent increases in development of shale hydrocarbon resources. There are significant gaps in the tools and research used to estimate fugitive emissions from oil and gas extraction. Two approaches exist for quantifying these emissions: atmospheric (or 'top down') studies, which measure methane fluxes remotely, or inventory-based ('bottom up') studies, which aggregate leakage rates on an equipment-specific basis. Bottom-up studies require counting or estimating how many devices might be leaking (called an 'activity count'), as well as how much each device might leak on average (an 'emissions factor'). In a real-world inventory, there is uncertainty in both activity counts and emissions factors. Even at the well level there are significant disagreements in data reporting. For example, some prior studies noted a ~5x difference in the number of reported well completions in the United States between EPA and private data sources. The purpose of this work is to address activity count uncertainty by using machine learning algorithms to classify oilfield surface facilities using high-resolution spatial imagery. This method can help estimate venting and fugitive emissions sources from regions where reporting of oilfield equipment is incomplete or non-existent. This work will utilize high resolution satellite imagery to count well pads in the Bakken oil field of North Dakota. This initial study examines an area of ~2,000 km2 with ~1000 well pads. We compare different machine learning classification techniques, and explore the impact of training set size, input variables, and image segmentation settings to develop efficient and robust techniques identifying well pads. We discuss the tradeoffs inherent to different classification algorithms, and determine the optimal algorithms for oilfield feature detection. In the future, the results of this work will be leveraged to be provide activity counts of oilfield surface equipment including tanks, pumpjacks, and holding ponds.
Kumar, J Vijay; Baghirath, P Venkat; Naishadham, P Parameswar; Suneetha, Sujai; Suneetha, Lavanya; Sreedevi, P
2015-01-01
To determine if long-term highly active antiretroviral therapy (HAART) therapy alters salivary flow rate and also to compare its relation of CD4 count with unstimulated and stimulated whole saliva. A cross-sectional study was performed on 150 individuals divided into three groups. Group I (50 human immunodeficiency virus (HIV) seropositive patients, but not on HAART therapy), Group II (50 HIV-infected subjects and on HAART for less than 3 years called short-term HAART), Group III (50 HIV-infected subjects and on HAART for more than or equal to 3 years called long-term HAART). Spitting method proposed by Navazesh and Kumar was used for the measurement of unstimulated and stimulated salivary flow rate. Chi-square test and analysis of variance (ANOVA) were used for statistical analysis. The mean CD4 count was 424.78 ± 187.03, 497.82 ± 206.11 and 537.6 ± 264.00 in the respective groups. Majority of the patients in all the groups had a CD4 count between 401 and 600. Both unstimulated and stimulated whole salivary (UWS and SWS) flow rates in Group I was found to be significantly higher than in Group II (P < 0.05). Unstimulated salivary flow rate between Group II and III subjects were also found to be statistically significant (P < 0.05). ANOVA performed between CD4 count and unstimulated and stimulated whole saliva in each group demonstrated a statistically significant relationship in Group II (P < 0.05). There were no significant results found between CD4 count and stimulated whole saliva in each groups. The reduction in CD4 cell counts were significantly associated with salivary flow rates of HIV-infected individuals who are on long-term HAART.
Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina
2016-07-27
Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.
2013-01-01
Purpose To determine if an existing ballroom dance classroom program meets national recommendations to engage children in moderate to vigorous physical activity (MVPA) for > 50% of class time and to determine class effects on body mass index (BMI). Design Prospective descriptive study. Setting Two New York City public schools. Subjects Seventy-nine fourth and fifth grade students. Measurements The System for Observing Fitness Instruction Time (SOFIT) and direct heart rate monitoring were used to determine subjects’ MVPA levels during class time. Weight and height were measured to calculate BMI. Analysis Means were calculated for continuous variables; frequency counts and percentages were calculated for categorical variables. Change in BMI percentiles was assessed using Bhapkar’s chi-square test of overall marginal homogeneity. Results Data from SOFIT observations showed that a mean of 50.0% and 67.0% of class time in the first and second halves of the program were spent in MVPA. Data from the heart rate monitoring data revealed that 71.1% of students were at ≥25% heart rate reserve, indicating MVPA, for ≥50% of class time. Improvement was seen in BMI percentile (P=0.051). Conclusion Ballroom dance provides MVPA in elementary school children for ≥50 % of class time and has a positive impact on BMI percentiles. PMID:22208413
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinohara, K., E-mail: shinohara.koji@jaea.go.jp; Ochiai, K.; Sukegawa, A.
In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons.more » The results suggested that the concept of a multi-stage detection system will work in practice.« less
[Hematological Evaluation and Monitoring in Adult Patients Diagnosed With Schizophrenia].
Tamayo Martínez, Nathalie; Bohórquez Peñaranda, Adriana Patricia; García Valencia, Jenny; Jaramillo González, Luis Eduardo; Ávila, Mauricio J; Gómez-Restrepo, Carlos; Arenas González, María Luisa
2015-01-01
To guide the clinician in taking decisions on the best strategies for assessing and monitoring the risk of blood disorders in adults diagnosed with schizophrenia in pharmacological treatment. A clinical practice guideline was developed following the guidelines of the Methodological Guide of the Ministry of Social Protection to collect evidence and grade recommendations. De novoliterature researchwas performed. With the use of antipsychotics there isriskofreducción in the leukocyte count and the risk of agranulocytosis,the later associated with the use of clozapine, although it is a rare event(0.8%) can be fatal; this effect occurs most frequently in the first twelve weeks of treatment and the risk is maintained aroundthe first year of it. The recommendations were considered strongin all hematologic related monitoring.A blood count should be taken at the start of pharmacological treatment. If the patient is started on clozapine one shouldbe taken weekly during the first three months, monthly until completing one year and every six months thereafter. If there is a decrease in white blood cell count the patient should be monitored regularly, stopping if is a less than 3,500 cells/mm(3) and consider referral if is less than 2,000 cells/mm(3). Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.
In-line assay monitor for uranium hexafluoride
Wallace, Steven A.
1981-01-01
An in-line assay monitor for determining the content of uranium-235 in a uranium hexafluoride gas isotopic separation system is provided which removes the necessity of complete access to the operating parameters of the system for determining the uranium-235 content. The monitor is intended for uses such as safeguard applications to assure that weapons grade uranium is not being produced in an enrichment cascade. The method and monitor for carrying out the method involve cooling of a radiation pervious chamber connected in fluid communication with the selected point in the system to withdraw a specimen and solidify the specimen in the chamber. The specimen is irradiated by means of an ionizing radiation source of energy different from that of the 185 keV gamma emissions from the uranium-235 present in the specimen. Simultaneously, the gamma emissions from the uranium-235 of the specimen and the source emissions transmitted through the sample are counted and stored in a multiple channel analyzer. The uranium-235 content of the specimen is determined from the comparison of the accumulated 185 keV energy counts and the reference energy counts. The latter is used to measure the total uranium isotopic content of the specimen. The process eliminates the necessity of knowing the system operating conditions and yet obtains the necessary data without need for large scintillation crystals and sophisticated mechanical designs.
Goktekin, Mehmet C; Yilmaz, Mustafa
2018-06-01
In this research, the aim was to compare hematological data for the differentiation of subarachnoid hemorrhage, migraine attack, and other headache syndromes during consultation in emergency service. In this research, which was designed as retrospective case control study, hematological parameters (WBC, HgB, HCT, PLT, lymphocyte and neutrophile counts and neutrophile/lymphocyte rates) of the patients consulting to emergency service with SAH and migraine and other consulting patients complaining mainly from headache and having normal cranial CT were analysed. Sixty migraine attack patients (F/M:47/13), 57 SAH patients (F/M:30/27), and 53 patients except migraine having normal brain CT (F/M:36/17) who were consulted to emergency service with headache complaint were included in our research. WBC, Hct, HgB, MCV, PLT, MPV, LY, Neu counts, and NY/LY rates were found to differentiate between SAH and migraine. WBC, PLT, MPV, LY, and Neu rates were found to differentiate between SAH and HS patients. Only Hct, HgB, MCV, and NY/LY rates were found to differ meaningfully between SAH and migraine patients but these rates were not found to have meaningful difference between SAH and HS patients. In addition, an increase in WBC counts and NY/LY rates and decrease in MPV counts in ROC analysis were found to be more specific for SAH. WBC, HgB, HCT, PLT, lymphocyte and Neu counts, and NY/LY rates can indicate distinguishing SAH and migraine. WBC, HgB, HCT, PLT, lymphocyte and Neu counts can indicate to the clinician a differentiation of SAH and other headache syndromes.
The interference of medical radionuclides with occupational in vivo gamma spectrometry.
Kol, R; Pelled, O; Canfi, A; Gilad, Y; German, U; Laichter, Y; Lantsberg, S; Fuksbrauner, R; Gold, B
2003-06-01
Radiation workers undergo routine monitoring for the evaluation of external and internal radiation exposures. The monitoring of internal exposures involves gamma spectrometry of the whole body (whole body counting) and measurements of excreta samples. Medical procedures involving internal administration of radioactive radionuclides are widely and commonly used. Medical radionuclides are typically short-lived, but high activities are generally administered, whereas occupational radionuclides are mostly long-lived and, if present, are found generally in relatively smaller quantities. The aim of the present work was to study the interference of some common medical radionuclides (201Tl, 9mTc, 57Co, and 131I) with the detection of internal occupational exposures to natural uranium and to 137Cs. Workers having undergone a medical procedure with one of the radionuclides mentioned above were asked to give frequent urine samples and to undergo whole body and thyroid counting with phoswich detectors operated at the Nuclear Research Center Negev. Urine and whole body counting monitoring were continued as long as radioactivity was detectable by gamma spectrometry. The results indicate that the activity of medical radionuclides may interfere with interpretation of occupational intakes for months after administration.
Boreal partners in flight: Working together to build a regional research and monitoring program
Handel, Colleen M.; Bonney, Rick; Pashley, David N.; Cooper, Robert J.; Niles, Larry
1999-01-01
Boreal regions of western North America regularly support breeding populations of 130 species of landbirds, including 68 Nearctic-Neotropical migrants. Primary conservation concerns within the region include increased timber harvesting, insect outbreaks, fire suppression, mining, impacts of military training activities, urbanization, and recreational activities. Under auspices of Partners in Flight, biologists, land and resource managers, and conservationists from Alaska and western Canada have combined efforts to develop a regional research and monitoring program for landbirds. An experimental monitoring program has been under way during the past four years to test the relative statistical power and cost-effectiveness of various monitoring methods in Alaska. Joint efforts currently include the Alaska Checklist Project on National Wildlife Refuges, 75 Breeding Bird Surveys along the road system, 122 Off-road Point Count routes, 27 Monitoring Avian Productivity and Survivorship banding sites, and 8 migration banding stations. The ultimate goal is to design a comprehensive monitoring program that is sensitive to changes in population size, survival rates, and productivity, but robust enough to accommodate logistical constraints that arise when working in vast, roadless areas with limited funds and staff. Primary challenges that must be faced to assure the long-term future of such a program are obtaining long-term commitment from resource agencies in the region, integrating this program with other national and regional programs that address those species and habitats that are inadequately monitored by established techniques, and developing cooperative research, monitoring, and management programs at the landscape level.
Multianode cylindrical proportional counter for high count rates
Hanson, J.A.; Kopp, M.K.
1980-05-23
A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (< 60 keV) at count rates of greater than 10/sup 5/ counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.
Multianode cylindrical proportional counter for high count rates
Hanson, James A.; Kopp, Manfred K.
1981-01-01
A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (<60 keV) at count rates of greater than 10.sup.5 counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.
Dark-count-less photon-counting x-ray computed tomography system using a YAP-MPPC detector
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2012-10-01
A high-sensitive X-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and a dark-count-less photon-counting CT system was developed. X-ray photons are detected using a YAP(Ce) [cerium-doped yttrium aluminum perovskite] single crystal scintillator and an MPPC (multipixel photon counter). Photocurrents are amplified by a high-speed current-voltage amplifier, and smooth event pulses from an integrator are sent to a high-speed comparator. Then, logical pulses are produced from the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The image contrast of gadolinium medium slightly fell with increase in lower-level voltage (Vl) of the comparator. The dark count rate was 0 cps, and the count rate for the CT was approximately 250 kcps.
LONGITUDINAL MONITORING OF TREE AIRBORNE POLLEN IN JAPAN.
Kishikawa, Reiko; Kotoh, Eiko; Oshikawa, Chie; Soh, Nobuo; Shimoda, Terufumi; Saito, Akemi; Sahashi, Norio; Enomoto, Tadao; Usami, Atsushi; Teranishi, Hidetoyo; Fujisaki, Yohko; Yokoyama, Toshitaka; Murayama, Kohji; Imai, Tohru; Fukutomi, Yuma; Taniguchi, Masami; Iwanaga, Tomoaki
2017-01-01
In Japan patients with Japanese Cedar (JC) pollinosis have increased nation widely since the latter of 1970's. The Ministry of Health and Welfare of Japanese Governments has begun to take preventive measures against JC pollinosis and airborne pollen monitoring has begun to investigate as a causative agent since 1986. We have estimated the longitudinal investigation result for successful prevention and treatment against pollinosis in Japan. We have monitored airborne pollen all year around since July 1986 by gravitational pollen sampler, Durham's sampler, at more than 20 locations in the Japanese Islands. Pollen samples were sent to our hospital and counted pollen number per cm 2 after stained by Calberla solution and then classified main pollen grains as a causative agent of pollinosis. JC pollen number was the most of all, more than 40%, next cypress family, about 20%. They were occupied of more than 60% of all and they increased with the remarkable annual fluctuation as the allergen of JC pollinosis. Beech family pollen counting were also increasing and occupied about 10% of all pollen counts. In Hokkaido the prevalence of birch family pollen count was larger than that in other districts. There is cross-reactivity between beech and birch family which related with oral allergic syndrome.Perspective and Conclusion: In future new occurrences of oral allergy syndrome due to increasing allergic tree pollen grains would be appeared. The contentious pollen research should be important for patients with pollinosis in Japan.
Kalpatthi, Ram; Thompson, Bruce; Lu, Ming; Wang, Winfred C; Patel, Niren; Kutlar, Abdullah; Howard, Thomas; Luchtman-Jones, Lori; Miller, Scott T
2013-02-01
To investigate the concordance of blood count indices measured locally and at a central laboratory. In a multi-center clinical trial of hydroxyurea therapy in infants with sickle cell anemia (BABY HUG), the concordance between blood count indices measured locally and at a central laboratory was investigated. Local laboratory measurements of neutrophil and monocyte counts were significantly higher (44% and 37%, respectively) compared to the central measurements (p<0.0001), and mean corpuscular volume (MCV) was higher centrally. Overnight shipping with processing delay causes spurious reductions in absolute neutrophil count (ANC) and absolute monocyte count (AMC) that may result in incorrect monitoring decisions in multicenter clinical trials. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Montana Kids Count Data Book and County Profiles, 1994.
ERIC Educational Resources Information Center
Healthy Mothers, Healthy Babies--The Montana Coalition, Helena.
This Kids Count publication is the first to examine statewide trends in the well-being of Montana's children. The statistical portrait is based on 13 indicators of well-being: (1) low birthweight rate; (2) infant mortality rate; (3) child death rate; (4) teen violent death rate; (5) percent of public school enrollment in Chapter 1 programs; (6)…
HgCdTe APD-based linear-mode photon counting components and ladar receivers
NASA Astrophysics Data System (ADS)
Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.
2011-05-01
Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.
Battaile, Brian C; Trites, Andrew W
2013-01-01
We propose a method to model the physiological link between somatic survival and reproductive output that reduces the number of parameters that need to be estimated by models designed to determine combinations of birth and death rates that produce historic counts of animal populations. We applied our Reproduction and Somatic Survival Linked (RSSL) method to the population counts of three species of North Pacific pinnipeds (harbor seals, Phoca vitulina richardii (Gray, 1864); northern fur seals, Callorhinus ursinus (L., 1758); and Steller sea lions, Eumetopias jubatus (Schreber, 1776))--and found our model outperformed traditional models when fitting vital rates to common types of limited datasets, such as those from counts of pups and adults. However, our model did not perform as well when these basic counts of animals were augmented with additional observations of ratios of juveniles to total non-pups. In this case, the failure of the ratios to improve model performance may indicate that the relationship between survival and reproduction is redefined or disassociated as populations change over time or that the ratio of juveniles to total non-pups is not a meaningful index of vital rates. Overall, our RSSL models show advantages to linking survival and reproduction within models to estimate the vital rates of pinnipeds and other species that have limited time-series of counts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, H.; Dean, J.; Privas, E.
2015-03-15
Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses amore » P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)« less
The Program for Regional and International Shorebird Monitoring (PRISM)
Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.; Morrison, R.I.G.; Skagen, S.K.
2005-01-01
This report describes the "Program for Regional and International Shorebird Monitoring" (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird conservation plans recently completed in Canada and the United States. The goals of PRISM are to (1) estimate the size of breeding population of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for each of these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. PRISM has four main components: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-breeding surveys, and neotropical surveys. Progress on, and action items for, each major component are described. The more important major tasks for immediate action are carrying out the northern surveys, conducting regional analyses to design the program of migration counts, and evaluating aerial photographic surveys for migration and winter counts.
In-line assay monitor for uranium hexafluoride
Wallace, S.A.
1980-03-21
An in-line assay monitor for determining the content of uranium-235 in a uranium hexafluoride gas isotopic separation system is provided which removes the necessity of complete access to the operating parameters of the system for determining the uranium-235 content. The method and monitor for carrying out the method involve cooling of a radiation pervious chamber connected in fluid communication with the selected point in the system to withdraw a specimen and solidify the specimen in the chamber. The specimen is irradiated by means of an ionizing radiation source of energy different from that of the 185 keV gamma emissions from uranium-235. The uranium-235 content of the specimen is determined from comparison of the accumulated 185 keV energy counts and reference energy counts. The latter is used to measure the total uranium isotopic content of the specimen.
Watanuki, Shoichi; Tashiro, Manabu; Miyake, Masayasu; Ishikawa, Yoichi; Itoh, Masatoshi; Yanai, Kazuhiko; Sakemi, Yasuhiro; Fukuda, Hiroshi; Ishii, Keizo
2010-07-01
Positron emission tomography (PET) scanners require periodic monitoring in order to maintain scanner performance. The aim of the present study was to examine the deterioration of PET scanner performance caused by aging. We retrospectively examined PET scanner performance alterations in terms of sensitivity, spatial resolution, false coincidences due to scatter and random coincidences based on 13 years of follow-up data, including data when the PET scanner underwent an overhaul at the 10th year after installation. Sensitivity and scatter fraction were calculated by using cross calibration factor (CCF) measurement data, which are collected routinely. Efficacy of the examining the sensitivity and scatter was confirmed by NEMA measurements. Trans-axial resolution was measured as full width at half-maximum (FWHM) and full width at tenth-maximum (FWTM) at 0-20 cm offset from the field of view (FOV) center at the time of installation, 8 years after installation, and immediately after the overhaul. Random coincidence rate fraction was measured in a wide range of count rates before and after the overhaul. The results indicated that the total reduction of sensitivity during the first 10 years was 41% of the initial value in terms of NEMA measurement, and that the annual reduction of sensitivity progressed at a rate of 4.7% per year in terms of CCF measurement data. The changes in sensitivity can be calculated using CCF measurement data. Regarding the spatial resolution, mean FWHM and FWTM values were increased by 1.7 and 3.6%, respectively, in 8 years after installation. The relative scatter fraction was significantly increased compared with that before the overhaul. The random fraction decreased by 10-15% after the overhaul within a certain range of random count rates (1-120 kcps). In the case of our scanner, the parameter that displayed the largest change was the sensitivity, and this change was thought to be caused by the reduction of photomultiplier tube (PMT) gain, although the changes in PMT gain can cause various types of performance deterioration, as investigated in this study. We observed that the sensitivity of our PET scanner generally deteriorated due to aging. Sensitivity monitoring using CCF measurements can be an easy and useful method for monitoring and maintaining the performance of PET scanners against aging. Since the data were obtained from a single scanner, the authors would encourage the initiation of a follow-up study involving various scanners.
Schein, Stan; Ahmad, Kareem M
2006-11-01
A rod transmits absorption of a single photon by what appears to be a small reduction in the small number of quanta of neurotransmitter (Q(count)) that it releases within the integration period ( approximately 0.1 s) of a rod bipolar dendrite. Due to the quantal and stochastic nature of release, discrete distributions of Q(count) for darkness versus one isomerization of rhodopsin (R*) overlap. We suggested that release must be regular to narrow these distributions, reduce overlap, reduce the rate of false positives, and increase transmission efficiency (the fraction of R* events that are identified as light). Unsurprisingly, higher quantal release rates (Q(rates)) yield higher efficiencies. Focusing here on the effect of small changes in Q(rate), we find that a slightly higher Q(rate) yields greatly reduced efficiency, due to a necessarily fixed quantal-count threshold. To stabilize efficiency in the face of drift in Q(rate), the dendrite needs to regulate the biochemical realization of its quantal-count threshold with respect to its Q(count). These considerations reveal the mathematical role of calcium-based negative feedback and suggest a helpful role for spontaneous R*. In addition, to stabilize efficiency in the face of drift in degree of regularity, efficiency should be approximately 50%, similar to measurements.
When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors.
O'Connell, Sandra; ÓLaighin, Gearóid; Quinlan, Leo R
2017-01-01
Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures for quantifying physical activity it is important that activity-monitoring devices be both sensitive and specific in recording actual steps taken and disregard non-stepping body movements. The objective of this study was to assess the specificity of five activity monitors during a variety of prescribed non-stepping activities. Participants wore five activity monitors simultaneously for a variety of prescribed activities including deskwork, taking an elevator, taking a bus journey, automobile driving, washing and drying dishes; functional reaching task; indoor cycling; outdoor cycling; and indoor rowing. Each task was carried out for either a specific duration of time or over a specific distance. Activity monitors tested were the ActivPAL micro™, NL-2000™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2)™, Fitbit One™ and Jawbone UP™. Participants were video-recorded while carrying out the prescribed activities and the false positive step count registered on each activity monitor was obtained and compared to the video. All activity monitors registered a significant number of false positive steps per minute during one or more of the prescribed activities. The Withings™ activity performed best, registering a significant number of false positive steps per minute during the outdoor cycling activity only (P = 0.025). The Jawbone™ registered a significant number of false positive steps during the functional reaching task and while washing and drying dishes, which involved arm and hand movement (P < 0.01 for both). The ActivPAL™ registered a significant number of false positive steps during the cycling exercises (P < 0.001 for both). As a number of false positive steps were registered on the activity monitors during the non-stepping activities, the authors conclude that non-stepping physical activities can result in the false detection of steps. This can negatively affect the quantification of physical activity with regard to step count as an output. The Withings™ activity monitor performed best with regard to specificity during the activities of daily living tested.
NASA Astrophysics Data System (ADS)
Nieuwkerk, D.; Ulrich, R. M.; Paul, J. H.; Hubbard, K.; Kirkpatrick, B. A.; Fanara, T. A.; Bruzek, S.; Hoeglund, A.
2016-02-01
Harmful algal blooms of the dinoflagellate Karenia brevis can cause massive fish-kills and marine mammal mortalities, as well as impact human health via the consumption of brevetoxin-contaminated shellfish and the inhalation of aerosolized toxins. There is a strong effort to predict human health impacts by monitoring the bloom stages of K. brevis, and to prevent health impacts by closing shellfish beds when K. brevis cell concentrations reach toxic levels. The current standard method for quantifying K. brevis is by microscopic enumeration, which requires taxonomic expertise to discern K. brevis cells from other Karenia species as well as a long turnover time to generate data, which limits the number of water samples that can be processed. This EPA-funded study compared a variety of technologies against the current standard (microscopic counts) to quantify the number of K. brevis cells per liter in the water column. Results of this study showed a strong correlation between Real Time Nucleic Acid Sequence-Based Amplification (RT-NASBA) and enumeration by microscopy performed by members of the Florida Fish and Wildlife Research Institute, who are responsible for such monitoring. We are adapting the bench-top RT-NASBA assay to the AmpliFire platform (a handheld sensor that can be used in the field), for point of need K. brevis detection. These handheld sensors will be used by a trained volunteer network and government agencies (FWC, NOAA, and Mote Marine Lab.) to quantify K. brevis cells in the water column of core Gulf of Mexico sites; the results from these sensors will be reported back to the GCOOS observation systems to provide real-time monitoring of K. brevis counts. The real-time information will allow agencies to better monitor fishery closures and predict human health impacts of harmful algal blooms, because a larger number of samples can be processed each week, as the NASBA process removes the rate-limiting step of microscope time.
Why count trees? Volunteer motivations and experiences with tree monitoring in New York City
Michelle L. Johnson; Lindsay K. Campbell; Erika S. Svendsen; Philip Silva
2018-01-01
Volunteer programs can benefit from a deeper understanding of the motivations and experiences of people engaged in citizen science. Research to date has studied motivations of citizen scientists and tree-planting volunteers. Less work has focused on tree-monitoring volunteers, a role that is rapidly increasing as more cities involve the public in monitoring the urban...
The use of mist nets as a tool for bird population monitoring
E.H. Dunn; C. John Ralph
2004-01-01
Mist nets are an important tool for population monitoring, here defi ned as assessment of species composition, relative abundance, population size, and demography. We review the strengths and limitations of mist netting for monitoring purposes, based on papers in this volume and other literature. Advantages of using mist nets over aural or visual count methods include...
Embedded and conventional ultrasonic sensors for monitoring acoustic emission during thermal fatigue
NASA Astrophysics Data System (ADS)
Trujillo, Blaine; Zagrai, Andrei
2016-04-01
Acoustic emission is widely used for monitoring pressure vessels, pipes, critical infrastructure, as well as land, sea and air vehicles. It is one of dominant approaches to explore material degradation under fatigue and events leading to material fracture. Addressing a recent interest in structural health monitoring of space vehicles, a need has emerged to evaluate material deterioration due to thermal fatigue during spacecraft atmospheric reentry. Thermal fatigue experiments were conducted, in which aluminum plates were subjected to localized heating and acoustic emission was monitoring by embedded and conventional acoustic emission sensors positioned at various distances from a heat source. At the same time, surface temperature of aluminum plates was monitored using an IR camera. Acoustic emission counts collected by embedded sensors were compared to counts measured with conventional acoustic emission sensors. Both types of sensors show noticeable increase of acoustic emission activity as localized heating source was applied to aluminum plates. Experimental data demonstrate correlation between temperature increase on the surface of the plates and increase in measured acoustic emission activity. It is concluded that under particular conditions, embedded piezoelectric wafer active sensors can be used for acoustic emission monitoring of thermally-induced structural degradation.
Use of Aerial Photography to Monitor Fall Chinook Salmon Spawning in the Columbia River
DOE Office of Scientific and Technical Information (OSTI.GOV)
Visser, Richard H.; Dauble, Dennis D.; Geist, David R.
2002-11-01
This paper compares two methods for enumerating salmon redds and their application to monitoring spawning activity. Aerial photographs of fall chinook salmon spawning areas in the Hanford Reach of the Columbia River were digitized and mapped using Geographic Information Systems (GIS) techniques in 1994 and 1995 as part of an annual assessment of the population. The number of visible redds from these photographs were compared to counts obtained from visual surveys with fixed wing aircraft. The proportion of the total redds within each of five general survey areas was similar for the two monitoring techniques. However, the total number ofmore » redds based on aerial photographs was 2.2 and 3.0 times higher than those observed during visual surveys for 1994 and 1995, respectively. The divergence in redd counts was most evident near peak spawning activity when the number of redds within individual spawning clusters exceeded 500. Aerial photography improved our ability to monitor numbers of visible salmon redds and to quantify habitat use.« less
Harrison, Samantha L; Horton, Elizabeth J; Smith, Robert; Sandland, Carolyn J; Steiner, Michael C; Morgan, Mike D L; Singh, Sally J
2013-01-01
To test the accuracy of a multi-sensor activity monitor (SWM) in detecting slow walking speeds in patients with chronic obstructive pulmonary disease (COPD). Concerns have been expressed regarding the use of pedometers in patient populations. Although activity monitors are more sophisticated devices, their accuracy at detecting slow walking speeds common in patients with COPD has yet to be proven. A prospective observational study design was employed. An incremental shuttle walk test (ISWT) was completed by 57 patients with COPD wearing an SWM. The ISWT was repeated by 20 patients wearing the same SWM. Differences were identified between metabolic equivalents (METS) and between step-count across five levels of the ISWT (p < 0.001). Good within monitor reproducibility between two ISWT was identified for total energy expenditure and step-count (p < 0.001). The SWM is able to detect slow (standardized) speeds of walking and is an acceptable method for measuring physical activity in individuals disabled by COPD. Copyright © 2013 Elsevier Inc. All rights reserved.
Earth Occultation Monitoring with the Fermi Gamma Ray Burst Monitor
NASA Technical Reports Server (NTRS)
Wilson-Hodge, Colleen A.
2014-01-01
Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique (EOT). Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors for daily monitoring. Light curves, updated daily, are available on our website http://heastro.phys.lsu.edu/gbm. Our software is also capable of performing the Earth occultation monitoring using up to 128 energy bands, or any combination of those bands, using our 128-channel, 4-s CSPEC data. The GBM BGO detectors, sensitive from about 200 keV to 40 keV, can also be used with this technique. In our standard application of the EOT, we use a catalog of sources to drive the measurements. To ensure that our catalog is complete, our team has developed an Earth occultation imaging method. In this talk, I will describe both techniques and the current data products available. I will highlight recent and important results from the GBM EOT, including the current status of our observations of hard X-ray variations in the Crab Nebula.
Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M
2013-10-02
Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated with significantly lower HRV and higher levels of inflammatory markers. Exposure-associated declines in HRV were observed immediately following exposure while higher levels of CRP were not observed until 18 hours following exposure. Cardiovascular autonomic and inflammation responses may contribute to the pathophysiologic pathways that link SHS exposure with adverse cardiovascular outcomes.
Validity of two wearable monitors to estimate breaks from sedentary time
Lyden, Kate; Kozey-Keadle, Sarah L.; Staudenmayer, John W.; Freedson, Patty S.
2012-01-01
Investigations employing wearable monitors have begun to examine how sedentary time behaviors influence health. Purpose To demonstrate the utility of a measure of sedentary behavior and to validate the activPAL and ActiGraph GT3X for estimating measures of sedentary behavior: absolute number of breaks and break-rate. Methods Thirteen participants completed two, 10-hour conditions. During the baseline condition, participants performed normal daily activity and during the treatment condition, participants were asked to reduce and break-up their sedentary time. In each condition, participants wore two ActiGraph GT3X monitors and one activPAL. The ActiGraph was tested using the low frequency extension filter (AG-LFE) and the normal filter (AG-Norm). For both ActiGraph monitors two count cut-points to estimate sedentary time were examined: 100 and 150 counts∙min−1. Direct observation served as the criterion measure of total sedentary time, absolute number of breaks from sedentary time and break-rate (number of breaks per sedentary hour [brks.sed-hr−1]). Results Break-rate was the only metric sensitive to changes in behavior between baseline (5.1 [3.3 to 6.8] brks.sed-hr−1) and treatment conditions (7.3 [4.7 to 9.8] brks.sed-hr−1) (mean [95% CI]). The activPAL produced valid estimates of all sedentary behavior measures and was sensitive to changes in break-rate between conditions (baseline: 5.1 [2.8 to 7.1] brks.sed-hr−1, treatment: 8.0 [5.8 to 10.2] brks.sed-hr−1). In general, the AG-LFE and AG-Norm were not accurate in estimating break-rate or absolute number of breaks and were not sensitive to changes between conditions. Conclusion This study demonstrates the utility of expressing breaks from sedentary time as a rate per sedentary hour, a metric specifically relevant to free-living behavior, and provides further evidence that the activPAL is a valid tool to measure components of sedentary behavior in free-living environments. PMID:22648343
NASA Astrophysics Data System (ADS)
Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.
2013-04-01
High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.
Setup and Calibration of SLAC's Peripheral Monitoring Stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooper, C.
2004-09-03
The goals of this project were to troubleshoot, repair, calibrate, and establish documentation regarding SLAC's (Stanford Linear Accelerator Center's) PMS (Peripheral Monitoring Station) system. The PMS system consists of seven PMSs that continuously monitor skyshine (neutron and photon) radiation levels in SLAC's environment. Each PMS consists of a boron trifluoride (BF{sub 3}) neutron detector (model RS-P1-0802-104 or NW-G-20-12) and a Geiger Moeller (GM) gamma ray detector (model TGM N107 or LND 719) together with their respective electronics. Electronics for each detector are housed in Nuclear Instrument Modules (NIMs) and are plugged into a NIM bin in the station. All communicationmore » lines from the stations to the Main Control Center (MCC) were tested prior to troubleshooting. To test communication with MCC, a pulse generator (Systron Donner model 100C) was connected to each channel in the PMS and data at MCC was checked for consistency. If MCC displayed no data, the communication cables to MCC or the CAMAC (Computer Automated Measurement and Control) crates were in need of repair. If MCC did display data, then it was known that the communication lines were intact. All electronics from each station were brought into the lab for troubleshooting. Troubleshooting usually consisted of connecting an oscilloscope or scaler (Ortec model 871 or 775) at different points in the circuit of each detector to record simulated pulses produced by a pulse generator; the input and output pulses were compared to establish the location of any problems in the circuit. Once any problems were isolated, repairs were done accordingly. The detectors and electronics were then calibrated in the field using radioactive sources. Calibration is a process that determines the response of the detector. Detector response is defined as the ratio of the number of counts per minute interpreted by the detector to the amount of dose equivalent rate (in mrem per hour, either calculated or measured). Detector response for both detectors is dependent upon the energy of the incident radiation; this trend had to be accounted for in the calibration of the BF{sub 3} detector. Energy dependence did not have to be taken into consideration when calibrating the GM detectors since GM detector response is only dependent on radiation energy below 100 keV; SLAC only produces a spectrum of gamma radiation above 100 keV. For the GM detector, calibration consisted of bringing a {sup 137}Cs source and a NIST-calibrated RADCAL Radiation Monitor Controller (model 9010) out to the field; the absolute dose rate was determined by the RADCAL device while simultaneously irradiating the GM detector to obtain a scaler reading corresponding to counts per minute. Detector response was then calculated. Calibration of the BF{sub 3} detector was done using NIST certified neutron sources of known emission rates and energies. Five neutron sources ({sup 238}PuBe, {sup 238}PuB, {sup 238}PuF4, {sup 238}PuLi and {sup 252}Cf) with different energies were used to account for the energy dependence of the response. The actual neutron dose rate was calculated by date-correcting NIST source data and considering the direct dose rate and scattered dose rate. Once the total dose rate (sum of the direct and scattered dose rates) was known, the response vs. energy curve was plotted. The first station calibrated (PMS6) was calibrated with these five neutron sources; all subsequent stations were calibrated with one neutron source and the energy dependence was assumed to be the same.« less
The Fermilab ISDN Pilot Project: Experiences and future plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, D.E.; Lego, A.J.; Clifford, A.E.
1995-12-31
Fully operational in June of 1994, the Fermilab ISDN Pilot Project was started to gain insight into the costs and benefits of providing ISDN service to the homes of Fermilab researchers. Fourteen users were chosen from throughout Fermilab, but the number of Fermilab-employed spouses pushed the total user count to 20. Each home was equipped with a basic rate ISDN (BRI) line, a BRI Ethernet half-bridge, and an NT-1. An inter-departmental team coordinated the project. Usage at each home was tracked and frequent surveys were attempted. Lessons learned include: working with Ameritech can be difficult; careful monitoring is essential; andmore » configuration of home computing equipment is very time consuming. Plans include moving entirely to primary rate ISDN hubs, support for different home ISDN equipment and better usage and performance tracking.« less
Enumeration of Vibrio cholerae O1 in Bangladesh waters by fluorescent-antibody direct viable count.
Brayton, P R; Tamplin, M L; Huq, A; Colwell, R R
1987-01-01
A field trial to enumerate Vibrio cholerae O1 in aquatic environments in Bangladesh was conducted, comparing fluorescent-antibody direct viable count with culture detection by the most-probable-number index. Specificity of a monoclonal antibody prepared against the O1 antigen was assessed and incorporated into the fluorescence staining method. All pond and water samples yielded higher counts of viable V. cholerae O1 by fluorescent-antibody direct viable count than by the most-probable-number index. Fluorescence microscopy is a more sensitive detection system than culture methods because it allows the enumeration of both culturable and nonculturable cells and therefore provides more precise monitoring of microbiological water quality. PMID:3324967
Chelgren, Nathan D.; Pearl, Christopher A.; Bowerman, Jay; Adams, Michael J.
2007-01-01
From 2001 to 2005, we studied the demography and seasonal movement of Oregon spotted frogs (Rana pretiosa) translocated into created ponds in Dilman Meadow in central Oregon. Our objectives were to inform future monitoring and management at the site, and to elucidate poorly known aspects of the species’ population ecology. Movement rates revealed complementary use of sites seasonally, with one small spring being preferred during winter that was rarely used during the rest of the year. Growth rates were significantly higher in ponds that were not used for breeding, and larger size resulted in significantly higher survival. When variation in survival by size was accounted for there was little variation among ponds in survival. Seasonal estimates of survival were lowest for males during the breeding/post-breeding redistribution period, suggesting a high cost of breeding for males. Overwintering survival for both genders was relatively high. Our study supports others in suggesting Oregon spotted frogs are specific in their overwintering habitat requirements, and that predator-free springs may be of particular value. We suggest that any future monitoring include measures of the rate of pond succession. Demographic monitoring should include metrics of both frog reproduction and survival: counts of egg masses at all ponds during spring, and capture-recapture study of survival in mid and late summer when capture rates are highest. Additional study of early life stages would be particularly useful to broaden our understanding of the species’ ecology. Specifically, adding intensive capture and marking effort after larval transformation in fall would enable a full understanding of the annual life cycle. Complete study of the annual life cycle is needed to isolate the life stages and mechanisms through which Oregon spotted frogs are affected by stressors such as nonnative predators. Dilman Meadow, which lacks many hypothesized stressors, is an important reference for isolating the life stages most responsive to management elsewhere in the species’ range.
Growth Curve Models for Zero-Inflated Count Data: An Application to Smoking Behavior
ERIC Educational Resources Information Center
Liu, Hui; Powers, Daniel A.
2007-01-01
This article applies growth curve models to longitudinal count data characterized by an excess of zero counts. We discuss a zero-inflated Poisson regression model for longitudinal data in which the impact of covariates on the initial counts and the rate of change in counts over time is the focus of inference. Basic growth curve models using a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; ...
2017-10-09
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less
NASA Astrophysics Data System (ADS)
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; Hunt, Alan W.; Ludewigt, Bernhard
2018-01-01
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ∼6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2" (length) × 2" (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ∼3 Mcps. An experimental methodology was developed that uses the average current from the PMT's anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ∼3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.
NASA Astrophysics Data System (ADS)
Khwarahm, Nabaz; Dash, Jadunandan; Atkinson, Peter M.; Newnham, R. M.; Skjøth, C. A.; Adams-Groom, B.; Caulton, Eric; Head, K.
2014-05-01
Constructing accurate predictive models for grass and birch pollen in the air, the two most important aeroallergens, for areas with variable climate conditions such as the United Kingdom, require better understanding of the relationships between pollen count in the air and meteorological variables. Variations in daily birch and grass pollen counts and their relationship with daily meteorological variables were investigated for nine pollen monitoring sites for the period 2000-2010 in the United Kingdom. An active pollen count sampling method was employed at each of the monitoring stations to sample pollen from the atmosphere. The mechanism of this method is based on the volumetric spore traps of Hirst design (Hirst in Ann Appl Biol 39(2):257-265,
ERIC Educational Resources Information Center
Aslam, Abid; Grojec, Anna; Little, Céline; Maloney, Ticiana; Tamagni, Jordan
2014-01-01
"The State of the World's Children 2014 In Numbers: Every Child Counts" highlights the critical role data and monitoring play in realizing children's rights. Credible data, disseminated effectively and used correctly, make it possible to target interventions that help right the wrong of exclusion. Data do not, of themselves, change the…
Managing and Monitoring Birds Using Point Counts: Standards and Applications
C. John Ralph; Sam Droege; John R. Sauer
1995-01-01
The use of population size as a measure of health of a species has been a very common tool of ornithologists for many years (Lack 1954, 1966; Hutchinson 1978). Methods for surveying population size are detailed in Ralph and Scott (1981), the excellent compendium by Cooperrider and others (1986), and the manual by Koskimies and Vaisanen (1991). Many types of counting...
Beta/alpha continuous air monitor
Becker, Gregory K.; Martz, Dowell E.
1989-01-01
A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinguishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts.
Jean-Yves Courbois; Stephen L. Katz; Daniel J. Isaak; E. Ashley Steel; Russell F. Thurow; A. Michelle Wargo Rub; Tony Olsen; Chris E. Jordan
2008-01-01
Precise, unbiased estimates of population size are an essential tool for fisheries management. For a wide variety of salmonid fishes, redd counts from a sample of reaches are commonly used to monitor annual trends in abundance. Using a 9-year time series of georeferenced censuses of Chinook salmon (Oncorhynchus tshawytscha) redds from central Idaho,...
Micron2 Lab: Microfluidic Microbiology Lab Project
NASA Technical Reports Server (NTRS)
Burton, Aaron; Botkin, Douglas; Castro, Sarah; Crucian, Brian
2015-01-01
Microbial monitoring during spaceflight is crucial to maintain crew health and ensure water purifications systems are functioning properly. Current protocols for in-flight enumeration of bacteria in potable water systems require culture based methods. In this project, we aim to develop a flight- and microgravity-compatible flow cytometer capable of counting total microbial counts in the water supply and differentiating live from dead bacteria.
Comparison of methods for estimating bird abundance and trends from historical count data
Frank R. Thompson; Frank A. La Sorte
2008-01-01
The use of bird counts as indices has come under increasing scrutiny because assumptions concerning detection probabilities may not be met, but there also seems to be some resistance to use of model-based approaches to estimating abundance. We used data from the United States Forest Service, Southern Region bird monitoring program to compare several common approaches...
Hydrologic and water-quality data for the East River Basin in northeastern Wisconsin
Hughes, P.E.
1993-01-01
Mean concentrations for 5-day biochemical oxygen demand, total-phosphorus concentration, fecal-coliform counts, and fecal-streptococcus counts were higher at Bower Creek than any of the other sites monitored during 1985-86. Mean chlorophyll a concentrations were highest at the East River sites at Monroe Street in Green Bay and at Allouez Avenue bridge at Allouez.
Habitat relationships of landbirds in the Northern Region, USDA Forest Service
Richard L. Hutto; Jock S. Young
1999-01-01
A series of first-generation habitat-relationships models for 83 bird species were detected in a 3-year study on point counts conducted in association with the USDA Forest Service's Northern Region Landbird Monitoring Program. The models depict probabilities of detection for each of the bird species on 100-m-radius, 10-minute point counts conducted across a series...
Effect of repeated arthrocentesis on cytologic analysis of synovial fluid in dogs.
Berg, R I M; Sykes, J E; Kass, P H; Vernau, W
2009-01-01
Serial arthrocentesis and synovial fluid examination can be used to monitor treatment efficacy in immune-mediated polyarthritis (IMPA), but whether this procedure induces inflammation that interferes with test result interpretation is unknown. The aim of this study was to determine the effect of repeated arthrocentesis on synovial fluid cytology in healthy dogs. Nine healthy client-owned dogs. Prospective study. Arthrocentesis was performed under sedation on 4 joints (both carpi, 1 tarsus, 1 stifle) on each dog every 3 weeks, a total of 4 times. Automated cell counts were done on stifle fluid, smears were made, and differential cell counts done on smears from all joints. Slides were evaluated microscopically for erythrocyte numbers, total nucleated cell count, differential cell count, and cell morphology. Data were analyzed by 2-way analysis of variance. A total of 144 synovial fluid samples were examined. Repeated arthrocentesis was not associated with increases in synovial fluid neutrophil numbers. Mild mononuclear inflammation was detected in 13 samples from 6 dogs. Serial arthrocentesis at 3-week intervals can rarely be associated with mild mononuclear joint inflammation, but does not appear to induce neutrophilic inflammation, at least in healthy dogs, and can be useful to monitor treatment response in canine IMPA.
Gaburro, Julie; Duchemin, Jean-Bernard; Paradkar, Prasad N; Nahavandi, Saeid; Bhatti, Asim
2016-11-18
Widespread in the tropics, the mosquito Aedes aegypti is an important vector of many viruses, posing a significant threat to human health. Vector monitoring often requires fecundity estimation by counting eggs laid by female mosquitoes. Traditionally, manual data analyses have been used but this requires a lot of effort and is the methods are prone to errors. An easy tool to assess the number of eggs laid would facilitate experimentation and vector control operations. This study introduces a built-in software called ICount allowing automatic egg counting of the mosquito vector, Aedes aegypti. ICount egg estimation compared to manual counting is statistically equivalent, making the software effective for automatic and semi-automatic data analysis. This technique also allows rapid analysis compared to manual methods. Finally, the software has been used to assess p-cresol oviposition choices under laboratory conditions in order to test the system with different egg densities. ICount is a powerful tool for fast and precise egg count analysis, freeing experimenters from manual data processing. Software access is free and its user-friendly interface allows easy use by non-experts. Its efficiency has been tested in our laboratory with oviposition dual choices of Aedes aegypti females. The next step will be the development of a mobile application, based on the ICount platform, for vector monitoring surveys in the field.
NASA Astrophysics Data System (ADS)
Adi, K.; Widodo, A. P.; Widodo, C. E.; Pamungkas, A.; Putranto, A. B.
2018-05-01
Traffic monitoring on road needs to be done, the counting of the number of vehicles passing the road is necessary. It is more emphasized for highway transportation management in order to prevent efforts. Therefore, it is necessary to develop a system that is able to counting the number of vehicles automatically. Video processing method is able to counting the number of vehicles automatically. This research has development a system of vehicle counting on toll road. This system includes processes of video acquisition, frame extraction, and image processing for each frame. Video acquisition is conducted in the morning, at noon, in the afternoon, and in the evening. This system employs of background subtraction and morphology methods on gray scale images for vehicle counting. The best vehicle counting results were obtained in the morning with a counting accuracy of 86.36 %, whereas the lowest accuracy was in the evening, at 21.43 %. Differences in morning and evening results are caused by different illumination in the morning and evening. This will cause the values in the image pixels to be different.
Kids Count Data Book, 2003: State Profiles of Child Well-Being.
ERIC Educational Resources Information Center
O'Hare, William P.
This Kids Count data book examines national and statewide trends in the well being of the nation's children. Statistical portraits are based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide, and suicide; (5) teen birth rate; (6)…
KIDS COUNT Data Book, 2002: State Profiles of Child Well-Being.
ERIC Educational Resources Information Center
O'Hare, William P.
This KIDS COUNT data book examines national and statewide trends in the well being of the nations children. Statistical portraits are based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide, and suicide; (5) teen birth rate; (6)…
KIDS COUNT Data Book, 2001: State Profiles of Child Well-Being.
ERIC Educational Resources Information Center
Annie E. Casey Foundation, Baltimore, MD.
This Kids Count report examines national and statewide trends in the well-being of the nation's children. The statistical portrait is based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide and suicide; (5) teen birth rate; (6)…
Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate
Schuck, Carsten; Pernice, Wolfram H. P.; Tang, Hong X.
2013-01-01
Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10−20 W/Hz1/2 level. PMID:23714696
NASA Astrophysics Data System (ADS)
Cooper, R. J.; Amman, M.; Vetter, K.
2018-04-01
High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.
Henry, J.J.
1961-09-01
A linear count-rate meter is designed to provide a highly linear output while receiving counting rates from one cycle per second to 100,000 cycles per second. Input pulses enter a linear discriminator and then are fed to a trigger circuit which produces positive pulses of uniform width and amplitude. The trigger circuit is connected to a one-shot multivibrator. The multivibrator output pulses have a selected width. Feedback means are provided for preventing transistor saturation in the multivibrator which improves the rise and decay times of the output pulses. The multivibrator is connected to a diode-switched, constant current metering circuit. A selected constant current is switched to an averaging circuit for each pulse received, and for a time determined by the received pulse width. The average output meter current is proportional to the product of the counting rate, the constant current, and the multivibrator output pulse width.
Persistence and Viability of Lecanicillium lecanii in Chinese Agricultural Soil
Peng, De-Liang; Zhou, Jie; Zhang, Xiao-Lin; Zhang, Zhao-Rong; Zhao, Jin-Jin; Wu, Yu-Huan
2015-01-01
The entomopathogenic fungus L. lecanii has been developed as biopesticides and used widely for biological control of several insects in agricultural practice. Due to the lack of isolation/count methods for L. lecanii in soil, the persistence of this fungus in soil appears to have attracted no attention. A selective medium and count method for L. lecanii in soil based on cetyl trimethyl ammonium bromide (CTAB) was developed, and then the persistence and viability of this fungus in soil were investigated under field conditions between 2012 and 2014. The results showed that the rate of recovery for L. lecanii in soil on the selective CTAB medium was satisfactory. The minimum CFUs for L. lecanii on the selective medium (0.5 g/L CTAB) was about 102 conidia/g soil. The L. lecanii density in soil declined quickly in the first month after inoculation with fungal conidia, kept stable for 6 to 10 months, and then decreased gradually until undetectable. L. lecanii could persist for at least 14 months in the agricultural soil of northern China. The colony growth, conidia yield and germination rate on plates, as well as the median lethal concentration or times (LC50 or LT50) to aphids, mycelium growth in aphids and sporulation on aphids of L. lecanii did not change significantly during the persistence in soil. In general, the count method developed here was a very useful tool for monitoring the dynamics of natural or introduced L. lecanii populations in soil, and the data on the persistence of L. lecanii in soil reported here were helpful for biological control and environmental risk assessment. PMID:26375030
Martin, J.; Kitchens, W.M.; Hines, J.E.
2007-01-01
Monitoring natural populations is often a necessary step to establish the conservation status of species and to help improve management decisions. Nevertheless, many monitoring programs do not effectively address primary sources of variability in monitoring data, which ultimately may limit the utility of monitoring in identifying declines and improving management. To illustrate the importance of taking into account detectability and spatial variation, we used a recently proposed estimator of abundance (superpopulation estimator) to estimate population size of and number of young produced by the Snail Kite (Rostrhamus sociabilis plumbeus) in Florida. During the last decade, primary recovery targets set by the U.S. Fish and Wildlife Service for the Snail Kite that were based on deficient monitoring programs (i.e., uncorrected counts) were close to being met (by simply increasing search effort during count surveys). During that same period, the Snail Kite population declined dramatically (by 55% from 1997 to 2005) and the number of young decreased by 70% between 1992?1998 and 1999?2005. Our results provide a strong practical case in favor of the argument that investing a sufficient amount of time and resources into designing and implementing monitoring programs that carefully address detectability and spatial variation is critical for the conservation of endangered species.
Material screening with HPGe counting station for PandaX experiment
NASA Astrophysics Data System (ADS)
Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Mao, Y.; Wang, H.; Wang, S.; Xie, P.; Zhang, T.
2016-12-01
A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.
The Effect of Age and Task Difficulty
ERIC Educational Resources Information Center
Mallo, Jason; Nordstrom, Cynthia R.; Bartels, Lynn K.; Traxler, Anthony
2007-01-01
Electronic Performance Monitoring (EPM) is a common technique used to record employee performance. EPM may include counting computer keystrokes, monitoring employees' phone calls or internet activity, or documenting time spent on work activities. Despite EPM's prevalence, no studies have examined how this management tool affects older workers--a…
DOT National Transportation Integrated Search
2011-09-06
Active Transportation in the form of bicycle and pedestrian traffic, is monitored for the Austin-Round Rock-San Marcos, TX region by the Capital Area Metropolitan Planning Organization using a variety of methods: automatic, manual and surveyed. This ...
Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method.
Wong, W H; Li, H; Uribe, J; Baghaei, H; Wang, Y; Yokoyama, S
2001-04-01
Higher count-rate gamma cameras than are currently used are needed if the technology is to fulfill its promise in positron coincidence imaging, radionuclide therapy dosimetry imaging, and cardiac first-pass imaging. The present single-crystal design coupled with conventional detector electronics and the traditional Anger-positioning algorithm hinder higher count-rate imaging because of the pileup of gamma-ray signals in the detector and electronics. At an interaction rate of 2 million events per second, the fraction of nonpileup events is < 20% of the total incident events. Hence, the recovery of pileup events can significantly increase the count-rate capability, increase the yield of imaging photons, and minimize image artifacts associated with pileups. A new technology to significantly enhance the performance of gamma cameras in this area is introduced. We introduce a new electronic design called high-yield-pileup-event-recovery (HYPER) electronics for processing the detector signal in gamma cameras so that the individual gamma energies and positions of pileup events, including multiple pileups, can be resolved and recovered despite the mixing of signals. To illustrate the feasibility of the design concept, we have developed a small gamma-camera prototype with the HYPER-Anger electronics. The camera has a 10 x 10 x 1 cm NaI(Tl) crystal with four photomultipliers. Hot-spot and line sources with very high 99mTc activities were imaged. The phantoms were imaged continuously from 60,000 to 3,500,000 counts per second to illustrate the efficacy of the method as a function of counting rates. At 2-3 million events per second, all phantoms were imaged with little distortion, pileup, and dead-time loss. At these counting rates, multiple pileup events (> or = 3 events piling together) were the predominate occurrences, and the HYPER circuit functioned well to resolve and recover these events. The full width at half maximum of the line-spread function at 3,000,000 counts per second was 1.6 times that at 60,000 counts per second. This feasibility study showed that the HYPER electronic concept works; it can significantly increase the count-rate capability and dose efficiency of gamma cameras. In a larger clinical camera, multiple HYPER-Anger circuits may be implemented to further improve the imaging counting rates that we have shown by multiple times. This technology would facilitate the use of gamma cameras for radionuclide therapy dosimetry imaging, cardiac first-pass imaging, and positron coincidence imaging and the simultaneous acquisition of transmission and emission data using different isotopes with less cross-contamination between transmission and emission data.
Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment
ERIC Educational Resources Information Center
Child Trends, 2010
2010-01-01
This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…
Seabird nest counts: A test of monitoring metrics using Red-tailed Tropicbirds
Seavy, N.E.; Reynolds, M.H.
2009-01-01
Counts of nesting birds are often used to monitor the abundance of breeding pairs at colonies. Mean incubation counts (MICs) are counts of nests with eggs at intervals that correspond to the mean incubation period of a species. The sum of all counts during the nesting season (MICtotal) and the highest single count during the season (MICmax) are metrics that can be generated from this method. However, the utility of these metrics as measures of the number of breeding pairs has not been well tested. We used two approaches to evaluate the bias and precision of MIC metrics for quantifying annual variation in the number of breeding Red-tailed Tropicbirds (Phaethon rubricauda) nesting on two islands in the Papahnaumokukea Marine National Monument in the northwest Hawaiian Islands. First, we used data from nest plots with individually marked birds to generate simulated MIC metrics that we compared to the known number of nesting individuals. The MICtotal overestimated the number of pairs by about 5%, whereas the MICmax underestimated the number of pairs by about 60%. However, both metrics exhibited similar precision. Second, we used a 12-yr time series of island-wide MICs to compare estimates of temporal trend and annual variation using the MICmax and MICtotal. The 95% confidence intervals for the trend estimates were overlapping and the residual standard errors for the two metrics were similar. Our results suggest that both metrics offered similar precision for indices of breeding pairs of Red-tailed Tropicbirds, but that MICtotal was more accurate. ?? 2009 Association of Field Ornithologists.
Hydroxyurea and Growth in Young Children With Sickle Cell Disease
Houston, Patricia E.; Wang, Winfred C.; Iyer, Rathi V.; Goldsmith, Jonathan; Casella, James F.; Reed, Caroline K.; Rogers, Zora R.; Waclawiw, Myron A.; Thompson, Bruce
2014-01-01
BACKGROUND: Growth impairment is a known complication of sickle cell disease. Effects of hydroxyurea (HU) on growth in very young children are not known. METHODS: Height, weight, BMI, and head circumference (HC) were compared with World Health Organization (WHO) standards in BABY HUG, a multicenter, randomized, double-blinded, placebo-controlled 2-year clinical trial of HU in 193 children 9 to 18 months of age. Anthropometric data were closely monitored and converted to z scores by using WHO standardized algorithms for descriptive analyses. The treatment and placebo groups were compared longitudinally by using a mixed model analysis. RESULTS: At entry, the z scores of BABY HUG children were higher than WHO norms. After 2 years of HU or placebo treatment, there were no significant differences between the groups, except for the mean HC z scores at study exit (HU: +0.8 versus placebo: +1.0, P = .05). Baseline z scores were the best predictors of z scores at study exit. The absolute neutrophil count, absolute reticulocyte count, and total white blood cell count had significant negative correlations with growth measures. CONCLUSIONS: Both groups had normal or near normal anthropometric measures during the study. The HC z scores at study entry and exit were slightly greater than WHO norms. Higher baseline white blood cell count, absolute reticulocyte count, and absolute neutrophil count were associated with poorer growth. The significance of the slightly lower HC in the treatment group at study exit is not clear. Trends toward normalization of weight and height and effects on HC will be monitored in ongoing BABY HUG follow-up studies. PMID:25157002
Pitch Counts in Youth Baseball and Softball: A Historical Review.
Feeley, Brian T; Schisel, Jessica; Agel, Julie
2018-07-01
Pitching injuries are getting increased attention in the mass media. Many references are made to pitch counts and the role they play in injury prevention. The original purpose of regulating the pitch count in youth baseball was to reduce injury and fatigue to pitchers. This article reviews the history and development of the pitch count limit in baseball, the effect it has had on injury, and the evidence regarding injury rates on softball windmill pitching. Literature search through PubMed, mass media, and organizational Web sites through June 2015. Pitch count limits and rest recommendations were introduced in 1996 after a survey of 28 orthopedic surgeons and baseball coaches showed injuries to baseball pitchers' arms were believed to be from the number of pitches thrown. Follow-up research led to revised recommendations with more detailed guidelines in 2006. Since that time, data show a relationship between innings pitched and upper extremity injury, but pitch type has not clearly been shown to affect injury rates. Current surveys of coaches and players show that coaches, parents, and athletes often do not adhere to these guidelines. There are no pitch count guidelines currently available in softball. The increase in participation in youth baseball and softball with an emphasis on early sport specialization in youth sports activities suggests that there will continue to be a rise in injury rates to young throwers. The published pitch counts are likely to positively affect injury rates but must be adhered to by athletes, coaches, and parents.
NASA Astrophysics Data System (ADS)
Torpin, Trevor; Boyd, Patricia T.; Smale, Alan P.
2015-01-01
The bright, unusual black-hole X-ray binary LMC X-3 has been monitored virtually continuously by the Japanese MAXI X-ray All-Sky Monitor aboard the International Space Station (Matsuoka, et al., PASJ, 2009) from August 2009 to the present. Comparison with RXTE PCA and ASM light curves during the ~2.33-year period of overlap demonstrate that despite slight differences in energy-band boundaries both the ASM and MAXI faithfully reproduce characteristics of the high-amplitude, nonperiodic long-term variability, on the order of 100-300 days, clearly seen in the more sensitive PCA monitoring. The mechanism for this variability at a timescale many times longer than the 1.7-day orbital period is still unknown. Models to explain the long-term variability invoke mechanisms such as changes in mass transfer rate, and/or a precessing warped accretion disk. Observations of LMC X-3 have not definitely determined whether wind accretion or Roche-love overflow is the driver of the long-term variability. Recent MAXI monitoring of LMC X-3 includes excellent coverage of a rare anomalous low state (ALS) where the X-ray source cannot be distinguished from the background, as well as several normal low states, in which the source count rate passes smoothly through a low, yet detectable value. Pointed Swift XRT and UVOT observations also sample this ALS and one normal low state well. We combine these data sets to study the correlations between the wavelength regimes observed during the ALS versus the normal low. We also examine the behavior of the X-ray hardness ratios using XRT and MAXI monitoring data during the ALS versus the normal low state.
NASA Astrophysics Data System (ADS)
Weekly, R. T.; Tolstoy, M.; Waldhauser, F.; Bohnenstiehl, D. R.; Kim, W.
2005-12-01
Monitoring of micro-seismicity within the bull's-eye region of the R2K ISS at 9deg49'N - 9deg51'N on the East Pacific Rise has been ongoing since October 2003. Results from the first deployment (October 2003 - April 2004) will be presented with hypocenters determined using relative-relocation techniques. Analysis shows that there is a gradual and ongoing increase in the rate of activity over the 7 months of the deployment. Mean event rates increase from 31 events/day for the first quarter of the deployment period, to 55, 105, and 131 events per day for the 2nd, 3rd and 4th quarters, respectively. This gradual increase in activity suggests long-term changes in the magma body or changes in the hydrothermal cracking front. Preliminary analysis and event counts for the 2004-2005 deployment will be presented to assess whether or not the build up in activity seen in 2003-2004 continued. Numerous brief swarms are observed throughout the deployment and their locations will be studied relative to temporal changes in the vent temperature monitoring as well as variations in the fluid chemistry (see Von Damm et al., same session). Early analysis suggests two dominant areas of recurrent activity, between M-vent and Bio-9 and between Bio-9 and Tube-worm pillar. The exceptionally well-characterized and monitored seafloor at this site allows for unprecedented correlation of observed seismic activity with local biology, geology, geochemical and hydrothermal monitoring. As results from different monitoring activities continue to come in, a detailed understanding of the linkages should emerge.
Radiation Discrimination in LiBaF3 Scintillator Using Digital Signal Processing Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aalseth, Craig E.; Bowyer, Sonya M.; Reeder, Paul L.
2002-11-01
The new scintillator material LiBaF3:Ce offers the possibility of measuring neutron or alpha count rates and energy spectra simultaneously while measuring gamma count rates and spectra using a single detector.
259 E Ohio, April 2014, Lindsay Light Radiological Survey
The count rates for the sidewalk ranged from 5,600 cpm to 16,800 cpm.There were two locations along Ontario St. with elevated count rates approaching thethreshold limit correlating to 7.1 pCi/g total thorium.
NASA Astrophysics Data System (ADS)
Mayer, D. P.; Kite, E. S.
2016-12-01
Sandblasting, aeolian infilling, and wind deflation all obliterate impact craters on Mars, complicating the use of crater counts for chronology, particularly on sedimentary rock surfaces. However, crater counts on sedimentary rocks can be exploited to constrain wind erosion rates. Relatively small, shallow craters are preferentially obliterated as a landscape undergoes erosion, so the size-frequency distribution of impact craters in a landscape undergoing steady exhumation will develop a shallower power-law slope than a simple production function. Estimating erosion rates is important for several reasons: (1) Wind erosion is a source of mass for the global dust cycle, so the global dust reservoir will disproportionately sample fast-eroding regions; (2) The pace and pattern of recent wind erosion is a sorely-needed constraint on models of the sculpting of Mars' sedimentary-rock mounds; (3) Near-surface complex organic matter on Mars is destroyed by radiation in <108 years, so high rates of surface exhumation are required for preservation of near-surface organic matter. We use crater counts from 18 HiRISE images over sedimentary rock deposits as the basis for estimating erosion rates. Each image was counted by ≥3 analysts and only features agreed on by ≥2 analysts were included in the erosion rate estimation. Erosion rates range from 0.1-0.2 {μ }m/yr across all images. These rates represent an upper limit on surface erosion by landscape lowering. At the conference we will discuss the within and between-image variability of erosion rates and their implications for recent geological processes on Mars.
Dynamic time-correlated single-photon counting laser ranging
NASA Astrophysics Data System (ADS)
Peng, Huan; Wang, Yu-rong; Meng, Wen-dong; Yan, Pei-qin; Li, Zhao-hui; Li, Chen; Pan, Hai-feng; Wu, Guang
2018-03-01
We demonstrate a photon counting laser ranging experiment with a four-channel single-photon detector (SPD). The multi-channel SPD improve the counting rate more than 4×107 cps, which makes possible for the distance measurement performed even in daylight. However, the time-correlated single-photon counting (TCSPC) technique cannot distill the signal easily while the fast moving targets are submersed in the strong background. We propose a dynamic TCSPC method for fast moving targets measurement by varying coincidence window in real time. In the experiment, we prove that targets with velocity of 5 km/s can be detected according to the method, while the echo rate is 20% with the background counts of more than 1.2×107 cps.
Puls, Robert W.; Eychaner, James H.; Powell, Robert M.
1996-01-01
Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.
Sprint, Gina; Cook, Diane; Weeks, Douglas; Dahmen, Jordana; La Fleur, Alyssa
2017-09-27
Time series data collected from sensors can be analyzed to monitor changes in physical activity as an individual makes a substantial lifestyle change, such as recovering from an injury or illness. In an inpatient rehabilitation setting, approaches to detect and explain changes in longitudinal physical activity data collected from wearable sensors can provide value as a monitoring, research, and motivating tool. We adapt and expand our Physical Activity Change Detection (PACD) approach to analyze changes in patient activity in such a setting. We use Fitbit Charge Heart Rate devices with two separate populations to continuously record data to evaluate PACD, nine participants in a hospitalized inpatient rehabilitation group and eight in a healthy control group. We apply PACD to minute-by-minute Fitbit data to quantify changes within and between the groups. The inpatient rehabilitation group exhibited greater variability in change throughout inpatient rehabilitation for both step count and heart rate, with the greatest change occurring at the end of the inpatient hospital stay, which exceeded day-to-day changes of the control group. Our additions to PACD support effective change analysis of wearable sensor data collected in an inpatient rehabilitation setting and provide insight to patients, clinicians, and researchers.
Measuring bacterial growth by refractive index tapered fiber optic biosensor.
Zibaii, Mohammad Ismail; Kazemi, Alireza; Latifi, Hamid; Azar, Mahmoud Karimi; Hosseini, Seyed Masoud; Ghezelaiagh, Mohammad Hossein
2010-12-02
A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-l-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.
Breathing Monitor Using Dye-Doped Optical Fiber
NASA Astrophysics Data System (ADS)
Muto, Shinzo; Fukasawa, Akihiko; Ogawa, Takayuki; Morisawa, Masayuki; Ito, Hiroshi
1990-08-01
A new monitoring system of human breathing using umbelliferon dye-doped plastic fiber has been studied. Under UV light pumping, the fiber which was used as a sensor head generates blue fluorescence depending on human expiration. By converting the light signal to electronic pulses, the counting of breathing and real-time monitoring of abnormal breathing such as a heavy cough or a cloggy sputum have easily been obtained.
Charged Particle Monitor on the Astrosat Mission
NASA Astrophysics Data System (ADS)
Rao, A. R.; Patil, M. H.; Bhargava, Yash; Khanna, Rakesh; Hingar, M. K.; Kutty, A. P. K.; Malkar, J. P.; Basak, Rupal; Sreekumar, S.; Samuel, Essy; Priya, P.; Vinod, P.; Bhattacharya, D.; Bhalerao, V.; Vadawale, S. V.; Mithun, N. P. S.; Pandiyan, R.; Subbarao, K.; Seetha, S.; Sarma, K. Suryanarayana
2017-06-01
Charged Particle Monitor (CPM) on-board the Astrosat satellite is an instrument designed to detect the flux of charged particles at the satellite location. A Cesium Iodide Thallium (CsI(Tl)) crystal is used with a Kapton window to detect protons with energies greater than 1 MeV. The ground calibration of CPM was done using gamma-rays from radioactive sources and protons from particle accelerators. Based on the ground calibration results, energy deposition above 1 MeV are accepted and particle counts are recorded. It is found that CPM counts are steady and the signal for the onset and exit of South Atlantic Anomaly (SAA) region are generated in a very reliable and stable manner.
Helble, Tyler A; D'Spain, Gerald L; Campbell, Greg S; Hildebrand, John A
2013-11-01
This paper demonstrates the importance of accounting for environmental effects on passive underwater acoustic monitoring results. The situation considered is the reduction in shipping off the California coast between 2008-2010 due to the recession and environmental legislation. The resulting variations in ocean noise change the probability of detecting marine mammal vocalizations. An acoustic model was used to calculate the time-varying probability of detecting humpback whale vocalizations under best-guess environmental conditions and varying noise. The uncorrected call counts suggest a diel pattern and an increase in calling over a two-year period; the corrected call counts show minimal evidence of these features.
Türetgen, Irfan; Cotuk, Aysin
2007-02-01
Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.
A novel, optical, on-line bacteria sensor for monitoring drinking water quality
Højris, Bo; Christensen, Sarah Christine Boesgaard; Albrechtsen, Hans-Jørgen; Smith, Christian; Dahlqvist, Mathis
2016-01-01
Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been developed. The sensor is based on 3D image recognition, and the obtained pictures are analyzed with algorithms considering 59 quantified image parameters. The sensor counts individual suspended particles and classifies them as either bacteria or abiotic particles. The technology is capable of distinguishing and quantifying bacteria and particles in pure and mixed suspensions, and the quantification correlates with total bacterial counts. Several field applications have demonstrated that the technology can monitor changes in the concentration of bacteria, and is thus well suited for rapid detection of critical conditions such as pollution events in drinking water. PMID:27040142
A novel, optical, on-line bacteria sensor for monitoring drinking water quality.
Højris, Bo; Christensen, Sarah Christine Boesgaard; Albrechtsen, Hans-Jørgen; Smith, Christian; Dahlqvist, Mathis
2016-04-04
Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been developed. The sensor is based on 3D image recognition, and the obtained pictures are analyzed with algorithms considering 59 quantified image parameters. The sensor counts individual suspended particles and classifies them as either bacteria or abiotic particles. The technology is capable of distinguishing and quantifying bacteria and particles in pure and mixed suspensions, and the quantification correlates with total bacterial counts. Several field applications have demonstrated that the technology can monitor changes in the concentration of bacteria, and is thus well suited for rapid detection of critical conditions such as pollution events in drinking water.
Asare, A. L.; Huda, H.; Klimczak, J. C.; Caldwell, C. W.
1998-01-01
Studies have shown that monitoring HIV-infected patients undergoing antiretroviral therapy is best represented by combined measurement of plasma HIV-1 RNA and CD4+ T-lymphocytes [1]. This pilot study at the University of Missouri-Columbia integrates molecular diagnostic and flow cytometric data reporting to provide current and historical HIV-1 RNA levels and CD4+ T-cell counts. The development of a single database for storage and retrieval of these values facilitates composite report generation that includes longitudinal HIV-1 RNA levels and CD4+ T-cell counts for all patients. Results are displayed in tables and plotted graphically within a web browser. This method of data presentation converts individual data points to more useful medical information and could provide clinicians with decision support for improved monitoring of HIV patients undergoing antiretroviral therapy. Images Figure 2 Figure 3 Figure 4 PMID:9929359
NASA Astrophysics Data System (ADS)
Wen, Xianfei; Enqvist, Andreas
2017-09-01
Cs2LiYCl6:Ce3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. A disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. They are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.
Design of a Monitoring Program for Northern Spotted Owls
Jonathan Bart; Douglas S. Robson
1995-01-01
This paper discusses methods for estimating population trends of Northern Spotted Owls (Strix occidentalis caurina) based on point counts. Although the monitoring program will have five distinct components, attention here is restricted to one of these: roadside surveys of territorial birds. Analyses of Breeding Bird Survey data and computer...
Lakes provide ecosystem services such as recreation, clean water, aesthetics, wildlife habitat, and nutrient attenuation. While numerous methods exist to monitor these services (e.g. visitor counts, opinion surveys, water quality monitoring, etc.) they are labor intensive to col...
Eliciting Disease Data from Wikipedia Articles.
Fairchild, Geoffrey; Del Valle, Sara Y; De Silva, Lalindra; Segre, Alberto M
2015-05-01
Traditional disease surveillance systems suffer from several disadvantages, including reporting lags and antiquated technology, that have caused a movement towards internet-based disease surveillance systems. Internet systems are particularly attractive for disease outbreaks because they can provide data in near real-time and can be verified by individuals around the globe. However, most existing systems have focused on disease monitoring and do not provide a data repository for policy makers or researchers. In order to fill this gap, we analyzed Wikipedia article content. We demonstrate how a named-entity recognizer can be trained to tag case counts, death counts, and hospitalization counts in the article narrative that achieves an F1 score of 0.753. We also show, using the 2014 West African Ebola virus disease epidemic article as a case study, that there are detailed time series data that are consistently updated that closely align with ground truth data. We argue that Wikipedia can be used to create the first community-driven open-source emerging disease detection, monitoring, and repository system.
Eliciting Disease Data from Wikipedia Articles
Fairchild, Geoffrey; Del Valle, Sara Y.; De Silva, Lalindra; Segre, Alberto M.
2017-01-01
Traditional disease surveillance systems suffer from several disadvantages, including reporting lags and antiquated technology, that have caused a movement towards internet-based disease surveillance systems. Internet systems are particularly attractive for disease outbreaks because they can provide data in near real-time and can be verified by individuals around the globe. However, most existing systems have focused on disease monitoring and do not provide a data repository for policy makers or researchers. In order to fill this gap, we analyzed Wikipedia article content. We demonstrate how a named-entity recognizer can be trained to tag case counts, death counts, and hospitalization counts in the article narrative that achieves an F1 score of 0.753. We also show, using the 2014 West African Ebola virus disease epidemic article as a case study, that there are detailed time series data that are consistently updated that closely align with ground truth data. We argue that Wikipedia can be used to create the first community-driven open-source emerging disease detection, monitoring, and repository system. PMID:28721308
Volatile organic compounds as markers of quality changes during the storage of wild rocket.
Luca, Alexandru; Kjær, Anders; Edelenbos, Merete
2017-10-01
The quality of leafy green vegetables changes during storage. Leaves become yellow or disintegrate, and an off-odor may develop. In addition, small amounts of volatile organic compounds (VOCs) are released. In this study, the release of acetone, carbon disulfide, dimethyl sulfide, nitromethane, pentane, 3-methylfuran, 2-ethylfuran, and dimethyl disulfide from wild rocket with different initial qualities was monitored during 8d storage at 10°C and correlated to aerobic bacteria counts, yeast and mold counts, and degree of tissue disintegration. The release of VOCs, except for 3-methylfuran, was influenced by the initial quality of the leaves. The release of pentane and 2-ethylfuran was related to the degree of tissue disintegration, and the release of dimethyl sulfide and dimethyl disulfide was related to the total aerobic bacteria count. The results demonstrated that VOCs can be used as markers for monitoring the complex quality changes taking place in packaged fresh produce during storage. Copyright © 2017 Elsevier Ltd. All rights reserved.
He, Bo; Zheng, Yuhuang; Liu, Meng; Zhou, Guoqiang; Chen, Xia; Mamadou, Diallo; He, Yan; Zhou, Huaying; Chen, Zi
2013-01-01
Immune reconstitution inflammation syndrome typically occurs within days after patients undergo highly active anti-retroviral therapy and is a big hurdle for effective treatment of AIDS patients. In this study, we monitored immune reconstitution inflammation syndrome occurrence in 238 AIDS patients treated with highly active anti-retroviral therapy. Among them, immune reconstitution inflammation syndrome occurred in 47 cases (19.7%). Immune reconstitution inflammation syndrome patients had significantly higher rate of opportunistic infection (p<0.001) and persistently lower CD4(+) cell count (p<0.001) compared to the non-immune reconstitution inflammation syndrome patients. In contrast, no significant differences in HIV RNA loads were observed between the immune reconstitution inflammation syndrome group and non-immune reconstitution inflammation syndrome group. These data suggest that a history of opportunistic infection and CD4(+) cell counts at baseline may function as risk factors for immune reconstitution inflammation syndrome occurrence in AIDS patients as well as potential prognostic markers. These findings will improve the management of AIDS with highly active anti-retroviral therapy. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.
Wahl, Yvonne; Düking, Peter; Droszez, Anna; Wahl, Patrick; Mester, Joachim
2017-01-01
Background: In the past years, there was an increasing development of physical activity tracker (Wearables). For recreational people, testing of these devices under walking or light jogging conditions might be sufficient. For (elite) athletes, however, scientific trustworthiness needs to be given for a broad spectrum of velocities or even fast changes in velocities reflecting the demands of the sport. Therefore, the aim was to evaluate the validity of eleven Wearables for monitoring step count, covered distance and energy expenditure (EE) under laboratory conditions with different constant and varying velocities. Methods: Twenty healthy sport students (10 men, 10 women) performed a running protocol consisting of four 5 min stages of different constant velocities (4.3; 7.2; 10.1; 13.0 km·h−1), a 5 min period of intermittent velocity, and a 2.4 km outdoor run (10.1 km·h−1) while wearing eleven different Wearables (Bodymedia Sensewear, Beurer AS 80, Polar Loop, Garmin Vivofit, Garmin Vivosmart, Garmin Vivoactive, Garmin Forerunner 920XT, Fitbit Charge, Fitbit Charge HR, Xaomi MiBand, Withings Pulse Ox). Step count, covered distance, and EE were evaluated by comparing each Wearable with a criterion method (Optogait system and manual counting for step count, treadmill for covered distance and indirect calorimetry for EE). Results: All Wearables, except Bodymedia Sensewear, Polar Loop, and Beurer AS80, revealed good validity (small MAPE, good ICC) for all constant and varying velocities for monitoring step count. For covered distance, all Wearables showed a very low ICC (<0.1) and high MAPE (up to 50%), revealing no good validity. The measurement of EE was acceptable for the Garmin, Fitbit and Withings Wearables (small to moderate MAPE), while Bodymedia Sensewear, Polar Loop, and Beurer AS80 showed a high MAPE up to 56% for all test conditions. Conclusion: In our study, most Wearables provide an acceptable level of validity for step counts at different constant and intermittent running velocities reflecting sports conditions. However, the covered distance, as well as the EE could not be assessed validly with the investigated Wearables. Consequently, covered distance and EE should not be monitored with the presented Wearables, in sport specific conditions. PMID:29018355
355 E Riverwalk, February 2017, Lindsay Light Radiological Survey
Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 2,600 cpm to 4,300 cpm. No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.
230 E. Ontario, May 2018, Lindsay Light Radiological Survey
Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,800 cpm to 2,600 cpm.No count rates were found at any time that exceeded the threshold limit of 7,366 cpm.
Ianakiev, Kiril D [Los Alamos, NM; Hsue, Sin Tao [Santa Fe, NM; Browne, Michael C [Los Alamos, NM; Audia, Jeffrey M [Abiquiu, NM
2006-07-25
The present invention includes an apparatus and corresponding method for temperature correction and count rate expansion of inorganic scintillation detectors. A temperature sensor is attached to an inorganic scintillation detector. The inorganic scintillation detector, due to interaction with incident radiation, creates light pulse signals. A photoreceiver processes the light pulse signals to current signals. Temperature correction circuitry that uses a fast light component signal, a slow light component signal, and the temperature signal from the temperature sensor to corrected an inorganic scintillation detector signal output and expanded the count rate.