Wise, Marcus B.; Thompson, Cyril V.
1998-01-01
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds.
Wise, M.B.; Thompson, C.V.
1998-07-14
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds. 3 figs.
Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve
2018-04-03
In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
ON-LINE TOXICITY MONITORS AND WATERSHED EARLY WARNING SYSTEMS
A Water Quality Early Warning System using On-line Toxicity Monitors (OTMs) has been deployed in the East Fork of the Little Miami River, Clermont County, OH. Living organisms have long been used to determine the toxicity of environmental samples. With advancements in electronic ...
40 CFR 89.308 - Sampling system requirements for gaseous emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) For each component (pump, sample line section, filters, and so forth) in the heated portion of the... mass and the oven temperature need be measured. (b) If water is removed by condensation, the sample gas temperature shall be monitored within the water trap or the sample dewpoint shall be monitored downstream. In...
40 CFR 89.308 - Sampling system requirements for gaseous emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) For each component (pump, sample line section, filters, and so forth) in the heated portion of the... mass and the oven temperature need be measured. (b) If water is removed by condensation, the sample gas temperature shall be monitored within the water trap or the sample dewpoint shall be monitored downstream. In...
40 CFR 89.308 - Sampling system requirements for gaseous emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) For each component (pump, sample line section, filters, and so forth) in the heated portion of the... mass and the oven temperature need be measured. (b) If water is removed by condensation, the sample gas temperature shall be monitored within the water trap or the sample dewpoint shall be monitored downstream. In...
40 CFR 89.308 - Sampling system requirements for gaseous emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) For each component (pump, sample line section, filters, and so forth) in the heated portion of the... mass and the oven temperature need be measured. (b) If water is removed by condensation, the sample gas temperature shall be monitored within the water trap or the sample dewpoint shall be monitored downstream. In...
40 CFR 89.308 - Sampling system requirements for gaseous emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) For each component (pump, sample line section, filters, and so forth) in the heated portion of the... mass and the oven temperature need be measured. (b) If water is removed by condensation, the sample gas temperature shall be monitored within the water trap or the sample dewpoint shall be monitored downstream. In...
Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources
NASA Astrophysics Data System (ADS)
Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai
2018-01-01
Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.
Optical monitor for water vapor concentration
Kebabian, Paul
1998-01-01
A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.
Optical monitor for water vapor concentration
Kebabian, P.
1998-06-02
A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma. 5 figs.
Investigation Of In-Line Monitoring Options At H Canyon/HB Line For Plutonium Oxide Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sexton, L.
2015-10-14
H Canyon and HB Line have a production goal of 1 MT per year of plutonium oxide feedstock for the MOX facility by FY17 (AFS-2 mission). In order to meet this goal, steps will need to be taken to improve processing efficiency. One concept for achieving this goal is to implement in-line process monitoring at key measurement points within the facilities. In-line monitoring during operations has the potential to increase throughput and efficiency while reducing costs associated with laboratory sample analysis. In the work reported here, we mapped the plutonium oxide process, identified key measurement points, investigated alternate technologies thatmore » could be used for in-line analysis, and initiated a throughput benefit analysis.« less
NASA Technical Reports Server (NTRS)
Maoz, Dan; Smith, Paul S.; Jannuzi, Buell T.; Kaspi, Shai; Netzer, Hagai
1994-01-01
We have monitored spectrophotometrically a subsample (28) of the Palomar-Green Bright Quasar Sample for 2 years in order to test for correlations between continuum and emission-line variations and to determine the timescales relevant to mapping the broad-line regions of high-luminosity active galactic nuclei (AGNs). Half of the quasars showed optical continuum variations with amplitudes in the range 20-75%. The rise and fall time for the continuum variations is typically 0.5-2 years. In most of the objects with continuum variations, we detect correlated variations in the broad H-alpha and H-beta emission lines. The amplitude of the line variations is usually 2-4 times smaller than the optical continuum fluctuations. We present light curves and analyze spectra for six of the variable quasars with 1000-10,000 A luminosity in the range 0.3-4 x 10(exp 45) ergs/s. In four of these objects the lines respond to the continuum variations with a lag that is smaller than or comparable to our typical sampling interval (a few months). Although continued monitoring is required to confirm these results and increase their accuracy, the present evidence indicates that quasars with the above luminosities have broad-line regions smaller than about 1 1t-yr. Two of the quasars monitored show no detectable line variations despite relatively large-amplitude continuum changes. This could be a stronger manifestation of the low-amplitude line-response phenomenon we observe in the other quasars.
Improving Aquatic Warbler Population Assessments by Accounting for Imperfect Detection
Oppel, Steffen; Marczakiewicz, Piotr; Lachmann, Lars; Grzywaczewski, Grzegorz
2014-01-01
Monitoring programs designed to assess changes in population size over time need to account for imperfect detection and provide estimates of precision around annual abundance estimates. Especially for species dependent on conservation management, robust monitoring is essential to evaluate the effectiveness of management. Many bird species of temperate grasslands depend on specific conservation management to maintain suitable breeding habitat. One such species is the Aquatic Warbler (Acrocephalus paludicola), which breeds in open fen mires in Central Europe. Aquatic Warbler populations have so far been assessed using a complete survey that aims to enumerate all singing males over a large area. Because this approach provides no estimate of precision and does not account for observation error, detecting moderate population changes is challenging. From 2011 to 2013 we trialled a new line transect sampling monitoring design in the Biebrza valley, Poland, to estimate abundance of singing male Aquatic Warblers. We surveyed Aquatic Warblers repeatedly along 50 randomly placed 1-km transects, and used binomial mixture models to estimate abundances per transect. The repeated line transect sampling required 150 observer days, and thus less effort than the traditional ‘full count’ approach (175 observer days). Aquatic Warbler abundance was highest at intermediate water levels, and detection probability varied between years and was influenced by vegetation height. A power analysis indicated that our line transect sampling design had a power of 68% to detect a 20% population change over 10 years, whereas raw count data had a 9% power to detect the same trend. Thus, by accounting for imperfect detection we increased the power to detect population changes. We recommend to adopt the repeated line transect sampling approach for monitoring Aquatic Warblers in Poland and in other important breeding areas to monitor changes in population size and the effects of habitat management. PMID:24713994
NASA Technical Reports Server (NTRS)
Griffin, T. P.; Naylor, G. R.; Haskell, W. D.; Breznik, G. S.; Mizell, C. A.; Steinrock, Todd (Technical Monitor)
2001-01-01
This paper presents an on-line mass spectrometer designed to monitor for cryogenic leaks on the Space Shuttle. The topics include: 1) Hazardous Gas Detection Lab; 2) LASRE Test Support; 3) Background; 4) Location of Systems; 5) Sample Lines for Gas Detection; 6) Problems with Current Systems; 7) Requirements for New System (Nitrogen and Helium Background); and 8) HGDS 2000. This paper is in viewgraph form.
Coaxial-probe contact-force monitoring for dielectric properties measurements
USDA-ARS?s Scientific Manuscript database
A means is described for measuring and monitoring the contact force applied to a material sample with an open-ended coaxial-line probe for purposes of measuring the dielectric properties of semisolid material samples such as fruit, vegetable and animal tissues. The equipment consists of a stainless...
Monitoring Coaxial-Probe Contact Force for Dielectric Properties Measurement
USDA-ARS?s Scientific Manuscript database
A means is described for measuring and monitoring the contact force applied to a material sample with an open-ended coaxial-line probe for purposes of measuring the dielectric properties of semisolid material samples such as fruit, vegetable and animal tissues. The equipment consists of a stainless...
Puchades, R.; Maquieira, A.; Atienza, J.; Herrero, M. A.
1990-01-01
Flow injection analysis (FIA) has emerged as an increasingly used laboratory tool in chemical analysis. Employment of the technique for on-line sample treatment and on-line measurement in chemical process control is a growing trend. This article reviews the recent applications of FlA. Most papers refer to on-line sample treatment. Although FIA is very well suited to continuous on-line process monitoring, few examples have been found in this areamost of them have been applied to water treatment or fermentation processes. PMID:18925271
40 CFR 98.264 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-process phosphoric acid process line. You can use existing plant procedures that are used for accounting... the process line. Conduct the representative bulk sampling using the applicable standard method in the...
On-line IR analyzer system to monitor cephamycin C loading on ion-exchange resin
NASA Astrophysics Data System (ADS)
Shank, Sheldon; Russ, Warren; Gravatt, Douglas; Lee, Wesley; Donahue, Steven M.
1992-08-01
An on-line infrared analyzer is being developed for monitoring cephamycin C loading on ion exchange resin. Accurate measurement of product loading offers productivity improvements with direct savings from product loss avoidance, minimized raw material cost, and reduced off-line laboratory testing. Ultrafiltered fermentation broth is fed onto ion exchange columns under conditions which adsorb the product, cephamycin C, to the resin while allowing impurities to pass unretained. Product loading is stopped when the on-line analyzer determines that resin capacity for adsorbing product is nearly exhausted. Infrared spectroscopy has been shown capable of quantifying cephamycin C in the process matrix at concentrations that support process control decisions. Process-to-analyzer interface challenges have been resolved, including sample conditioning requirements. Analyzer requirements have been defined. The sample conditioning station is under design.
USDA-ARS?s Scientific Manuscript database
This study compared the utility of three sampling methods for ecological monitoring based on: interchangeability of data (rank correlations), precision (coefficient of variation), cost (minutes/transect), and potential of each method to generate multiple indicators. Species richness and foliar cover...
Off-line-locked laser diode species monitor system
NASA Technical Reports Server (NTRS)
Lee, Jamine (Inventor); Goldstein, Neil (Inventor); Richtsmeier, Steven (Inventor); Bien, Fritz (Inventor); Gersh, Michael (Inventor)
1995-01-01
An off-line-locked laser diode species monitor system includes: reference means for including at least one known species having a first absorption wavelength; a laser source for irradiating the reference means and at least one sample species having a second absorption wavelength differing from the first absorption wavelength by a predetermined amount; means for locking the wavelength of the laser source to the first wavelength of the at least one known species in the reference means; a controller for defeating the means for locking and for displacing the laser source wavelength from said first absorption wavelength by said predetermined amount to the second absorption wavelength; and a sample detector device for determining laser radiation absorption at the second wavelength transmitted through the sample to detect the presence of the at least one sample species.
Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J
2015-01-27
Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05-1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed.
Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J.
2015-01-01
Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05–1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed. PMID:25633600
Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N
2003-02-01
An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.
How many fish? Comparison of two underwater visual sampling methods for monitoring fish communities
Sini, Maria; Vatikiotis, Konstantinos; Katsoupis, Christos
2018-01-01
Background Underwater visual surveys (UVSs) for monitoring fish communities are preferred over fishing surveys in certain habitats, such as rocky or coral reefs and seagrass beds and are the standard monitoring tool in many cases, especially in protected areas. However, despite their wide application there are potential biases, mainly due to imperfect detectability and the behavioral responses of fish to the observers. Methods The performance of two methods of UVSs were compared to test whether they give similar results in terms of fish population density, occupancy, species richness, and community composition. Distance sampling (line transects) and plot sampling (strip transects) were conducted at 31 rocky reef sites in the Aegean Sea (Greece) using SCUBA diving. Results Line transects generated significantly higher values of occupancy, species richness, and total fish density compared to strip transects. For most species, density estimates differed significantly between the two sampling methods. For secretive species and species avoiding the observers, the line transect method yielded higher estimates, as it accounted for imperfect detectability and utilized a larger survey area compared to the strip transect method. On the other hand, large-scale spatial patterns of species composition were similar for both methods. Discussion Overall, both methods presented a number of advantages and limitations, which should be considered in survey design. Line transects appear to be more suitable for surveying secretive species, while strip transects should be preferred at high fish densities and for species of high mobility. PMID:29942703
Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary
2010-11-01
To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
On-line multiple component analysis for efficient quantitative bioprocess development.
Dietzsch, Christian; Spadiut, Oliver; Herwig, Christoph
2013-02-20
On-line monitoring devices for the precise determination of a multitude of components are a prerequisite for fast bioprocess quantification. On-line measured values have to be checked for quality and consistency, in order to extract quantitative information from these data. In the present study we characterized a novel on-line sampling and analysis device comprising an automatic photometric robot. We connected this on-line device to a bioreactor and concomitantly measured six components (i.e. glucose, glycerol, ethanol, acetate, phosphate and ammonium) during different batch cultivations of Pichia pastoris. The on-line measured data did not show significant deviations from off-line taken samples and were consequently used for incremental rate and yield calculations. In this respect we highlighted the importance of data quality and discussed the phenomenon of error propagation. On-line calculated rates and yields depicted the physiological responses of the P. pastoris cells in unlimited and limited cultures. A more detailed analysis of the physiological state was possible by considering the off-line determined biomass dry weight and the calculation of specific rates. Here we present a novel device for on-line monitoring of bioprocesses, which ensures high data quality in real-time and therefore refers to a valuable tool for Process Analytical Technology (PAT). Copyright © 2012 Elsevier B.V. All rights reserved.
Bakri, Barbara; Weimer, Marco; Hauck, Gerrit; Reich, Gabriele
2015-11-01
Scope of the study was (1) to develop a lean quantitative calibration for real-time near-infrared (NIR) blend monitoring, which meets the requirements in early development of pharmaceutical products and (2) to compare the prediction performance of this approach with the results obtained from stratified sampling using a sample thief in combination with off-line high pressure liquid chromatography (HPLC) and at-line near-infrared chemical imaging (NIRCI). Tablets were manufactured from powder blends and analyzed with NIRCI and HPLC to verify the real-time results. The model formulation contained 25% w/w naproxen as a cohesive active pharmaceutical ingredient (API), microcrystalline cellulose and croscarmellose sodium as cohesive excipients and free-flowing mannitol. Five in-line NIR calibration approaches, all using the spectra from the end of the blending process as reference for PLS modeling, were compared in terms of selectivity, precision, prediction accuracy and robustness. High selectivity could be achieved with a "reduced" approach i.e. API and time saving approach (35% reduction of API amount) based on six concentration levels of the API with three levels realized by three independent powder blends and the additional levels obtained by simply increasing the API concentration in these blends. Accuracy and robustness were further improved by combining this calibration set with a second independent data set comprising different excipient concentrations and reflecting different environmental conditions. The combined calibration model was used to monitor the blending process of independent batches. For this model formulation the target concentration of the API could be achieved within 3 min indicating a short blending time. The in-line NIR approach was verified by stratified sampling HPLC and NIRCI results. All three methods revealed comparable results regarding blend end point determination. Differences in both mean API concentration and RSD values could be attributed to differences in effective sample size and thief sampling errors. This conclusion was supported by HPLC and NIRCI analysis of tablets manufactured from powder blends after different blending times. In summary, the study clearly demonstrates the ability to develop efficient and robust quantitative calibrations for real-time NIR powder blend monitoring with a reduced set of powder blends while avoiding any bias caused by physical sampling. Copyright © 2015 Elsevier B.V. All rights reserved.
Implementation of in-line infrared monitor in full-scale anaerobic digestion process.
Spanjers, H; Bouvier, J C; Steenweg, P; Bisschops, I; van Gils, W; Versprille, B
2006-01-01
During start up but also during normal operation, anaerobic reactor systems should be run and monitored carefully to secure trouble-free operation, because the process is vulnerable to disturbances such as temporary overloading, biomass wash out and influent toxicity. The present method of monitoring is usually by manual sampling and subsequent laboratory analysis. Data collection, processing and feedback to system operation is manual and ad hoc, and involves high-level operator skills and attention. As a result, systems tend to be designed at relatively conservative design loading rates resulting in significant over-sizing of reactors and thus increased systems cost. It is therefore desirable to have on-line and continuous access to performance data on influent and effluent quality. Relevant variables to indicate process performance include VFA, COD, alkalinity, sulphate, and, if aerobic post-treatment is considered, total nitrogen, ammonia and nitrate. Recently, mid-IR spectrometry was demonstrated on a pilot scale to be suitable for in-line simultaneous measurement of these variables. This paper describes a full-scale application of the technique to test its ability to monitor continuously and without human intervention the above variables simultaneously in two process streams. For VFA, COD, sulphate, ammonium and TKN good agreement was obtained between in-line and manual measurements. During a period of six months the in-line measurements had to be interrupted several times because of clogging. It appeared that the sample pre-treatment unit was not able to cope with high solids concentrations all the time.
Ehala, S; Vassiljeva, I; Kuldvee, R; Vilu, R; Kaljurand, M
2001-09-01
Capillary electrophoresis (CE) can be a valuable tool for on-line monitoring of bioprocesses. Production of organic acids by phosphorus-solubilizing bacteria and fermentation of UHT milk were monitored and controlled by use of a membrane-interfaced dialysis device and a home-made microsampler for a capillary electrophoresis unit. Use of this specially designed sampling device enabled rapid consecutive injections without interruption of the high voltage. No additional sample preparation was required. The time resolution of monitoring in this particular work was approximately 2 h, but could be reduced to 2 min. Analytes were detected at low microg mL(-1) levels with a reproducibility of approximately 10%. To demonstrate the potential of CE in processes of biotechnological interest, results from monitoring phosphate solubilization by bacteria were submitted to qualitative and quantitative analysis. Fermentation experiments on UHT milk showed that monitoring of the processes by CE can provide good resolution of complex mixtures, although for more specific, detailed characterization the identification of individual substances is needed.
Understanding fetal physiology and second line monitoring during labor.
Garabedian, C; De Jonckheere, J; Butruille, L; Deruelle, P; Storme, L; Houfflin-Debarge, V
2017-02-01
Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity.
Hausman, Debra S; Cambron, R Thomas; Sakr, Adel
2005-07-14
On-line Raman spectroscopy was used to evaluate the effect of blending time on low dose, 1%, blend uniformity of azimilide dihydrochloride. An 8 qt blender was used for the experiments and instrumented with a Raman probe through the I-bar port. The blender was slowed to 6.75 rpm to better illustrate the blending process (normal speed is 25 rpm). Uniformity was reached after 20 min of blending at 6.75 rpm (135 revolutions or 5.4 min at 25 rpm). On-line Raman analysis of blend uniformity provided more benefits than traditional thief sampling and off-line analysis. On-line Raman spectroscopy enabled generating data rich blend profiles, due to the ability to collect a large number of samples during the blending process (sampling every 20s). In addition, the Raman blend profile was rapidly generated, compared to the lengthy time to complete a blend profile with thief sampling and off-line analysis. The on-line Raman blend uniformity results were also significantly correlated (p-value < 0.05) to the HPLC uniformity results of thief samples.
On-Line Analyzer For Monitoring Trace Amounts Of Oil In Turbid Waters
NASA Astrophysics Data System (ADS)
Niemela, P.; Jaatinen, J.
1986-05-01
This report presents an automated analyzer which continuously monitors oil content of a sample water stream that flows through the analyzer. The measuring principle is based on the absorption of infrared radiation by oil molecules contained in the sample water. The wavelength band that is used in the measurement is at 3.4 μm, where different types of oils show nearly equal absorption. Another wavelength band of 3.6 μm, where oil has no absorption, is used to compensate the effect of turbidity, which is due to solid particles and oil droplets contained in the sample water. Before entering the analyzer the sample water flow is properly homogenized. To compensate the strong absorption by water molecules in these wavelength bands the sample water is compared with reference water. This is done by directing them alternately through the same measuring cell. The reference water is obtained from the sample water by ultrafiltration and it determines the base line for the contaminated sample water. To ensure the stability of the base line, temperature and pressure differences of the two waters are kept within adequate ranges. Areas of application of the analyzer are wide ranging i.a. from ships' discharge waters to waste waters of industrial processes. The first application of the analyzer is on board oil tankers to control the discharge process of bilge and ballast waters. The analyzer is the first that fully corresponds to the stringent regulations for oil content monitors by the International Maritime Organization (IMO). Pilot installations of the analyzer are made on industrial plants.
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
Near-real-time combustion monitoring for PCDD/PCDF indicators by CG-REMPI-TOFMS
The boiler exit flue gas of a municipal waste combustor was sampled to evaluate an on-line monitoring system for chlorobenzene congeners as indicators of polychlorinated dibenzodioxin and dibenzofuran (PCDD/PCDF) concentrations. Continuous measurements of chlorobenzene congeners ...
NASA Astrophysics Data System (ADS)
Okumura, Akihiko; Takada, Yasuaki; Watanabe, Susumu; Hashimoto, Hiroaki; Ezawa, Naoya; Seto, Yasuo; Takayama, Yasuo; Sekioka, Ryoji; Yamaguchi, Shintaro; Kishi, Shintaro; Satoh, Takafumi; Kondo, Tomohide; Nagashima, Hisayuki; Nagoya, Tomoki
2016-07-01
We propose detecting a fragment ion (Ph2As+) using counter-flow introduction atmospheric pressure chemical ionization ion trap mass spectrometry for sensitive air monitoring of chemical warfare vomiting agents diphenylchloroarsine (DA) and diphenylcyanoarsine (DC). The liquid sample containing of DA, DC, and bis(diphenylarsine)oxide (BDPAO) was heated in a dry air line, and the generated vapor was mixed into the humidified air flowing through the sampling line of a mass spectrometer. Humidity effect on the air monitoring was investigated by varying the humidity of the analyzed air sample. Evidence of the in-line conversion of DA and DC to diphenylarsine hydroxide (DPAH) and then BDPAO was obtained by comparing the chronograms of various ions from the beginning of heating. Multiple-stage mass spectrometry revealed that the protonated molecule (MH+) of DA, DC, DPAH, and BDPAO could produce Ph2As+ through their in-source fragmentation. Among the signals of the ions that were investigated, the Ph2As+ signal was the most intense and increased to reach a plateau with the increased air humidity, whereas the MH+ signal of DA decreased. It was suggested that DA and DC were converted in-line into BDPAO, which was a major source of Ph2As+.
Schutt, D.W.; Beck, G.O.
1974-01-01
The current in the beam of a particle accelerator is monitored with picosecond resolution by causing the beam to impinge upon the center conductor of a coaxial line, generating a pulse of electromagnetic energy in response thereto. This pulse is detected by means such as a sampling oscilloscope. (Official Gazette)
In-line monitoring of a pharmaceutical blending process using FT-Raman spectroscopy.
Vergote, G J; De Beer, T R M; Vervaet, C; Remon, J P; Baeyens, W R G; Diericx, N; Verpoort, F
2004-03-01
FT-Raman spectroscopy (in combination with a fibre optic probe) was evaluated as an in-line tool to monitor a blending process of diltiazem hydrochloride pellets and paraffinic wax beads. The mean square of differences (MSD) between two consecutive spectra was used to identify the time required to obtain a homogeneous mixture. A traditional end-sampling thief probe was used to collect samples, followed by HPLC analysis to verify the Raman data. Large variations were seen in the FT-Raman spectra logged during the initial minutes of the blending process using a binary mixture (ratio: 50/50, w/w) of diltiazem pellets and paraffinic wax beads (particle size: 800-1200 microm). The MSD-profiles showed that a homogeneous mixture was obtained after about 15 min blending. HPLC analysis confirmed these observations. The Raman data showed that the mixing kinetics depended on the particle size of the material and on the mixing speed. The results of this study proved that FT-Raman spectroscopy can be successfully implemented as an in-line monitoring tool for blending processes.
Facility fence-line monitoring using passive samplers
In 2009, the U.S. EPA executed a year-long field study at a refinery in Corpus Christi, Texas, to evaluate the use of passive diffusive sampling technology for assessing time-averaged benzene concentrations at the facility fence line. The study utilized 14-day time-integrated Car...
Patel, Bhumit A; Pinto, Nuno D S; Gospodarek, Adrian; Kilgore, Bruce; Goswami, Kudrat; Napoli, William N; Desai, Jayesh; Heo, Jun H; Panzera, Dominick; Pollard, David; Richardson, Daisy; Brower, Mark; Richardson, Douglas D
2017-11-07
Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.
Hecht, Mirco; Oehen, Bernadette; Schulze, Jürg; Brodmann, Peter; Bagutti, Claudia
2014-01-01
To obtain a reference status prior to cultivation of genetically modified oilseed rape (OSR, Brassica napus L.) in Switzerland, the occurrence of feral OSR was monitored along transportation routes and at processing sites. The focus was set on the detection of (transgenic) OSR along railway lines from the Swiss borders with Italy and France to the respective oilseed processing factories in Southern and Northern Switzerland (Ticino and region of Basel). A monitoring concept was developed to identify sites of largest risk of escape of genetically modified plants into the environment in Switzerland. Transport spillage of OSR seeds from railway goods cars particularly at risk hot spots such as switch yards and (un)loading points but also incidental and continuous spillage were considered. All OSR plants, including their hybridization partners which were collected at the respective monitoring sites were analyzed for the presence of transgenes by real-time PCR. On sampling lengths each of 4.2 and 5.7 km, respectively, 461 and 1,574 plants were sampled in Ticino and the region of Basel. OSR plants were found most frequently along the routes to the oilseed facilities, and in larger amounts on risk hot spots compared to sites of random sampling. At three locations in both monitored regions, transgenic B. napus line GT73 carrying the glyphosate resistance transgenes gox and CP4 epsps were detected (Ticino, 22 plants; in the region of Basel, 159).
On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor.
Qin, Guoxiu; Chen, Xilin; Guo, Xiaoqing; Ni, Ning
2016-08-01
For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line. Copyright © 2016 Elsevier Ltd. All rights reserved.
Guo, Wei-Liang; Du, Yi-Ping; Zhou, Yong-Can; Yang, Shuang; Lu, Jia-Hui; Zhao, Hong-Yu; Wang, Yao; Teng, Li-Rong
2012-03-01
An analytical procedure has been developed for at-line (fast off-line) monitoring of 4 key parameters including nisin titer (NT), the concentration of reducing sugars, cell concentration and pH during a nisin fermentation process. This procedure is based on near infrared (NIR) spectroscopy and Partial Least Squares (PLS). Samples without any preprocessing were collected at intervals of 1 h during fifteen batch of fermentations. These fermentation processes were implemented in 3 different 5 l fermentors at various conditions. NIR spectra of the samples were collected in 10 min. And then, PLS was used for modeling the relationship between NIR spectra and the key parameters which were determined by reference methods. Monte Carlo Partial Least Squares (MCPLS) was applied to identify the outliers and select the most efficacious methods for preprocessing spectra, wavelengths and the suitable number of latent variables (n (LV)). Then, the optimum models for determining NT, concentration of reducing sugars, cell concentration and pH were established. The correlation coefficients of calibration set (R (c)) were 0.8255, 0.9000, 0.9883 and 0.9581, respectively. These results demonstrated that this method can be successfully applied to at-line monitor of NT, concentration of reducing sugars, cell concentration and pH during nisin fermentation processes.
A review of microdialysis coupled to microchip electrophoresis for monitoring biological events
Saylor, Rachel A.; Lunte, Susan M.
2015-01-01
Microdialysis is a powerful sampling technique that enables monitoring of dynamic processes in vitro and in vivo. The combination of microdialysis with chromatographic or electrophoretic methods yields along with selective detection methods yields a “separation-based sensor” capable of monitoring multiple analytes in near real time. Analysis of microdialysis samples requires techniques that are fast (<1 min), have low volume requirements (nL–pL), and, ideally, can be employed on-line. Microchip electrophoresis fulfills these requirements and also permits the possibility of integrating sample preparation and manipulation with detection strategies directly on-chip. Microdialysis coupled to microchip electrophoresis has been employed for monitoring biological events in vivo and in vitro. This review discusses technical considerations for coupling microdialysis sampling and microchip electrophoresis, including various interface designs, and current applications in the field. PMID:25637011
NASA Astrophysics Data System (ADS)
Carstea, E.; Baker, A.; Johnson, R.; Reynolds, D. M.
2009-12-01
In-line fluorescence EEM monitoring has been performed over an eleven-day period for Bournbrook River, Birmingham, UK. River water was diverted to a portable laboratory via a continuous flow pump and filter system. Fluorescence excitation-emission matrices data was recorded every 3 minutes using a flow cell (1cm pathlength) coupled to a fiber optic probe. This real-time fluorescence EEM data (Excitation, 225-400 nm at 5 nm steps, emission, 280-500 nm at 2 nm steps) was collected 'in-line'and directly compared with the spectrophotometric properties and physical and chemical parameters of river water samples collected off-line at known time intervals. Over the monitoring period, minor pollution pulses from cross connections were detected and identified hourly along with a random diesel pollution event. This work addresses the practicalities of measuring and detecting fluorescence EEM in the field and discusses the potential of this technological approach for further understanding important hydrological and biogeochemical processes. Problems associated with fouling and system failure are also reported. Example of the data generated from the continuous fluorescence EEM monitoring.
Pollution Analyzing and Monitoring Instruments.
ERIC Educational Resources Information Center
1972
Compiled in this book is basic, technical information useful in a systems approach to pollution control. Descriptions and specifications are given of what is available in ready made, on-the-line commercial equipment for sampling, monitoring, measuring and continuously analyzing the multitudinous types of pollutants found in the air, water, soil,…
Monitoring the fracture behavior of SiCp/Al alloy composites using infrared lock-in thermography
NASA Astrophysics Data System (ADS)
Kordatos, E. Z.; Myriounis, D., P.; Hasan, S., T.; Matikas, T. E.
2009-03-01
his work deals with the study of fracture behavior of silicon carbide particle-reinforced (SiCp) A359 aluminum alloy matrix composites using an innovative nondestructive method based on lock-in thermography. The heat wave, generated by the thermo-mechanical coupling and the intrinsic energy dissipated during mechanical cyclic loading of the sample, was detected by an infrared camera. The coefficient of thermo-elasticity allows for the transformation of the temperature profiles into stresses. A new procedure was developed to determine the crack growth rate using thermographic mapping of the material undergoing fatigue: (a) The distribution of temperature and stresses at the surface of the specimen was monitored during the test. To this end, thermal images were obtained as a function of time and saved in the form of a movie. (b) The stresses were evaluated in a post-processing mode, along a series of equally spaced reference lines of the same length, set in front of the crack-starting notch. The idea was that the stress monitored at the location of a line versus time (or fatigue cycles) would exhibit an increase while the crack approaches the line, then attain a maximum when the crack tip was on the line. Due to the fact that the crack growth path could not be predicted and was not expected to follow a straight line in front of the notch, the stresses were monitored along a series of lines of a certain length, instead of a series of equally spaced points in front of the notch. The exact path of the crack could be easily determined by looking at the stress maxima along each of these reference lines. The thermographic results on the crack growth rate of the metal matrix composite (MMC) samples with three different heat treatments were correlated with measurements obtained by the conventional compliance method, and found to be in agreement.
Shu, Tongxin; Xia, Min; Chen, Jiahong; Silva, Clarence de
2017-11-05
Power management is crucial in the monitoring of a remote environment, especially when long-term monitoring is needed. Renewable energy sources such as solar and wind may be harvested to sustain a monitoring system. However, without proper power management, equipment within the monitoring system may become nonfunctional and, as a consequence, the data or events captured during the monitoring process will become inaccurate as well. This paper develops and applies a novel adaptive sampling algorithm for power management in the automated monitoring of the quality of water in an extensive and remote aquatic environment. Based on the data collected on line using sensor nodes, a data-driven adaptive sampling algorithm (DDASA) is developed for improving the power efficiency while ensuring the accuracy of sampled data. The developed algorithm is evaluated using two distinct key parameters, which are dissolved oxygen (DO) and turbidity. It is found that by dynamically changing the sampling frequency, the battery lifetime can be effectively prolonged while maintaining a required level of sampling accuracy. According to the simulation results, compared to a fixed sampling rate, approximately 30.66% of the battery energy can be saved for three months of continuous water quality monitoring. Using the same dataset to compare with a traditional adaptive sampling algorithm (ASA), while achieving around the same Normalized Mean Error (NME), DDASA is superior in saving 5.31% more battery energy.
Shu, Tongxin; Xia, Min; Chen, Jiahong; de Silva, Clarence
2017-01-01
Power management is crucial in the monitoring of a remote environment, especially when long-term monitoring is needed. Renewable energy sources such as solar and wind may be harvested to sustain a monitoring system. However, without proper power management, equipment within the monitoring system may become nonfunctional and, as a consequence, the data or events captured during the monitoring process will become inaccurate as well. This paper develops and applies a novel adaptive sampling algorithm for power management in the automated monitoring of the quality of water in an extensive and remote aquatic environment. Based on the data collected on line using sensor nodes, a data-driven adaptive sampling algorithm (DDASA) is developed for improving the power efficiency while ensuring the accuracy of sampled data. The developed algorithm is evaluated using two distinct key parameters, which are dissolved oxygen (DO) and turbidity. It is found that by dynamically changing the sampling frequency, the battery lifetime can be effectively prolonged while maintaining a required level of sampling accuracy. According to the simulation results, compared to a fixed sampling rate, approximately 30.66% of the battery energy can be saved for three months of continuous water quality monitoring. Using the same dataset to compare with a traditional adaptive sampling algorithm (ASA), while achieving around the same Normalized Mean Error (NME), DDASA is superior in saving 5.31% more battery energy. PMID:29113087
Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B
2018-04-27
Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.
Remote water monitoring system
NASA Technical Reports Server (NTRS)
Grana, D. C.; Haynes, D. P. (Inventor)
1978-01-01
A remote water monitoring system is described that integrates the functions of sampling, sample preservation, sample analysis, data transmission and remote operation. The system employs a floating buoy carrying an antenna connected by lines to one or more sampling units containing several sample chambers. Receipt of a command signal actuates a solenoid to open an intake valve outward from the sampling unit and communicates the water sample to an identifiable sample chamber. Such response to each signal receipt is repeated until all sample chambers are filled in a sample unit. Each sample taken is analyzed by an electrochemical sensor for a specific property and the data obtained is transmitted to a remote sending and receiving station. Thereafter, the samples remain isolated in the sample chambers until the sampling unit is recovered and the samples removed for further laboratory analysis.
De Beer, T R M; Allesø, M; Goethals, F; Coppens, A; Heyden, Y Vander; De Diego, H Lopez; Rantanen, J; Verpoort, F; Vervaet, C; Remon, J P; Baeyens, W R G
2007-11-01
The aim of the present study was to propose a strategy for the implementation of a Process Analytical Technology system in freeze-drying processes. Mannitol solutions, some of them supplied with NaCl, were used as models to freeze-dry. Noninvasive and in-line Raman measurements were continuously performed during lyophilization of the solutions to monitor real time the mannitol solid state, the end points of the different process steps (freezing, primary drying, secondary drying), and physical phenomena occurring during the process. At-line near-infrared (NIR) and X-ray powder diffractometry (XRPD) measurements were done to confirm the Raman conclusions and to find out additional information. The collected spectra during the processes were analyzed using principal component analysis and multivariate curve resolution. A two-level full factorial design was used to study the significant influence of process (freezing rate) and formulation variables (concentration of mannitol, concentration of NaCl, volume of freeze-dried sample) upon freeze-drying. Raman spectroscopy was able to monitor (i) the mannitol solid state (amorphous, alpha, beta, delta, and hemihydrate), (ii) several process step end points (end of mannitol crystallization during freezing, primary drying), and (iii) physical phenomena occurring during freeze-drying (onset of ice nucleation, onset of mannitol crystallization during the freezing step, onset of ice sublimation). NIR proved to be a more sensitive tool to monitor sublimation than Raman spectroscopy, while XRPD helped to unravel the mannitol hemihydrate in the samples. The experimental design results showed that several process and formulation variables significantly influence different aspects of lyophilization and that both are interrelated. Raman spectroscopy (in-line) and NIR spectroscopy and XRPD (at-line) not only allowed the real-time monitoring of mannitol freeze-drying processes but also helped (in combination with experimental design) us to understand the process.
Microbiology of beef carcasses before and after slaughterline automation.
Whelehan, O. P.; Hudson, W. R.; Roberts, T. A.
1986-01-01
The bacterial status of beef carcasses at a commercial abattoir was monitored before and after slaughterline automation. Bacterial counts did not differ significantly overall (P greater than 0.05) between the original manual line and the automated line for either morning or afternoon slaughter. On the manual line counts in the morning were lower than those from carcasses slaughtered in the afternoon, but on the automated line there was no difference between morning and afternoon counts. Due to highly significant line X sample site interaction for both morning and afternoon counts, overall differences among sample sites were not found by analysis of variance. However, principal components analysis revealed a significant shift in bacterial contamination among some sites due to slaughterline changes. The incidence of Enterobacteriaceae increased marginally following automation. PMID:3701039
To assess the ecological condition of streams and rivers in Oregon, we sampled 146 sites
in summer, 1997 as part of the U.S. EPA's Environmental Monitoring and Assessment Program.
Sample reaches were selected using a systematic, randomized sample design from the blue-line n...
Deshommes, Elise; Laroche, Laurent; Deveau, Dominique; Nour, Shokoufeh; Prévost, Michèle
2017-09-05
Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (<2 yr) or old partial lead service line replacements (PLSLRs). Total and particulate lead concentrations were measured using repeat sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.
Real-time monitoring of volatile organic compounds using chemical ionization mass spectrometry
Mowry, Curtis Dale; Thornberg, Steven Michael
1999-01-01
A system for on-line quantitative monitoring of volatile organic compounds (VOCs) includes pressure reduction means for carrying a gaseous sample from a first location to a measuring input location maintained at a low pressure, the system utilizing active feedback to keep both the vapor flow and pressure to a chemical ionization mode mass spectrometer constant. A multiple input manifold for VOC and gas distribution permits a combination of calibration gases or samples to be applied to the spectrometer.
Monitoring Biological Activity at Geothermal Power Plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peter Pryfogle
2005-09-01
The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has beenmore » evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.« less
NASA Astrophysics Data System (ADS)
Termopoli, Veronica; Famiglini, Giorgio; Palma, Pierangela; Cappiello, Achille; Vandergrift, Gregory W.; Krogh, Erik T.; Gill, Chris G.
2016-02-01
Polycyclic aromatic hydrocarbons (PAHs) are USEPA regulated priority pollutants. Their low aqueous solubility requires very sensitive analytical methods for their detection, typically involving preconcentration steps. Presented is the first demonstrated `proof of concept' use of condensed phase membrane introduction mass spectrometry (CP-MIMS) coupled with direct liquid electron ionization (DEI) for the direct, on-line measurement of PAHs in aqueous samples. DEI is very well suited for the ionization of PAHs and other nonpolar compounds, and is not significantly influenced by the co-elution of matrix components. Linear calibration data for low ppb levels of aqueous naphthalene, anthracene, and pyrene is demonstrated, with measured detection limits of 4 ppb. Analytical response times (t10%-90% signal rise) ranged from 2.8 min for naphthalene to 4.7 min for pyrene. Both intra- and interday reproducibility has been assessed (<3% and 5% RSD, respectively). Direct measurements of ppb level PAHs spiked in a variety of real, complex environmental sample matrices is examined, including natural waters, sea waters, and a hydrocarbon extraction production waste water sample. For these spiked, complex samples, direct PAH measurement by CP-MIMS-DEI yielded minimal signal suppression from sample matrix effects (81%-104%). We demonstrate the use of this analytical approach to directly monitor real-time changes in aqueous PAH concentrations with potential applications for continuous on-line monitoring strategies and binding/adsorption studies in heterogeneous samples.
Anomalous H-beta Variability in the 2014 NGC 5548 AGN-STORM Monitoring Campaign
NASA Astrophysics Data System (ADS)
Pei, Liuyi; AGN STORM Collaboration
2016-06-01
Reverberation mapping programs generally find that the continuum and H-beta flux variations in AGNs are well correlated. In the 2014 AGN STORM monitoring program for NGC 5548, we observed a distinct decorrelation of the emission-line light curves from the AGN continuum light curve during the second half of the six-month campaign. This effect was first detected for the C IV, Ly a, HeII 1640 and SiIV/OIV] 1400 lines in Hubble Space Telescope data, then observed for the H-beta line in ground-based data taken during the same monitoring period. We present measurements of the H-beta lags, equivalent width variations, and line responsivity changes during our campaign. We show that the AGN demonstrated unusual behavior in that the broad H-beta responsivity to flux variations decreased significantly during the second half of the campaign. The discovery of this decorrelation phenomenon was made possible by the high cadence and long duration of our monitoring campaign. More multi-wavelength observing campaigns with high sampling cadence, high signal-to-noise ratio, and long temporal baseline are needed for other AGNs in order to determine the prevalence of this phenomenon and to understand its physical origin.
Monitoring of antisolvent crystallization of sodium scutellarein by combined FBRM-PVM-NIR.
Liu, Xuesong; Sun, Di; Wang, Feng; Wu, Yongjiang; Chen, Yong; Wang, Longhu
2011-06-01
Antisolvent crystallization can be used as an alternative to cooling or evaporation for the separation and purification of solid product in the pharmaceutical industry. To improve the process understanding of antisolvent crystallization, the use of in-line tools is vital. In this study, the process analytical technology (PAT) tools including focused beam reflectance measurement (FBRM), particle video microscope (PVM), and near-infrared spectroscopy (NIRS) were utilized to monitor antisolvent crystallization of sodium scutellarein. FBRM was used to monitor chord count and chord length distribution of sodium scutellarein particles in the crystallizer, and PVM, as an in-line video camera, provided pictures imaging particle shape and dimension. In addition, a quantitative model of PLS was established by in-line NIRS to detect the concentration of sodium scutellarein in the solvent and good calibration statistics were obtained (r(2) = 0.976) with the residual predictive deviation value of 11.3. The discussion over sensitivities, strengths, and weaknesses of the PAT tools may be helpful in selection of suitable PAT techniques. These in-line techniques eliminate the need for sample preparation and offer a time-saving approach to understand and monitor antisolvent crystallization process. Copyright © 2011 Wiley-Liss, Inc.
Hughes, Rachel R; Scown, David; Lenehan, Claire E
2015-01-01
Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Saari, Markus; Rossi, Pekka; Blomberg von der Geest, Kalle; Mäkinen, Ari; Postila, Heini; Marttila, Hannu
2017-04-01
High metal concentrations in natural waters is one of the key environmental and health problems globally. Continuous in-situ analysis of metals from runoff water is technically challenging but essential for the better understanding of processes which lead to pollutant transport. Currently, typical analytical methods for monitoring elements in liquids are off-line laboratory methods such as ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (ICP combined with a mass spectrometer). Disadvantage of the both techniques is time consuming sample collection, preparation, and off-line analysis at laboratory conditions. Thus use of these techniques lack possibility for real-time monitoring of element transport. We combined a novel high resolution on-line metal concentration monitoring with catchment scale physical hydrological modelling in Mustijoki river in Southern Finland in order to study dynamics of processes and form a predictive warning system for leaching of metals. A novel on-line measurement technique based on micro plasma emission spectroscopy (MPES) is tested for on-line detection of selected elements (e.g. Na, Mg, Al, K, Ca, Fe, Ni, Cu, Cd and Pb) in runoff waters. The preliminary results indicate that MPES can sufficiently detect and monitor metal concentrations from river water. Water and Soil Assessment Tool (SWAT) catchment scale model was further calibrated with high resolution metal concentration data. We show that by combining high resolution monitoring and catchment scale physical based modelling, further process studies and creation of early warning systems, for example to optimization of drinking water uptake from rivers, can be achieved.
NASA Astrophysics Data System (ADS)
Bristow, Tony W. T.; Ray, Andrew D.; O'Kearney-McMullan, Anne; Lim, Louise; McCullough, Bryan; Zammataro, Alessio
2014-10-01
For on-line monitoring of chemical reactions (batch or continuous flow), mass spectrometry (MS) can provide data to (1) determine the fate of starting materials and reagents, (2) confirm the presence of the desired product, (3) identify intermediates and impurities, (4) determine steady state conditions and point of completion, and (5) speed up process optimization. Recent developments in small footprint atmospheric pressure ionization portable mass spectrometers further enable this coupling, as the mass spectrometer can be easily positioned with the reaction system to be studied. A major issue for this combination is the transfer of a sample that is representative of the reaction and also compatible with the mass spectrometer. This is particularly challenging as high concentrations of reagents and products can be encountered in organic synthesis. The application of a portable mass spectrometer for on-line characterization of flow chemical synthesis has been evaluated by coupling a Microsaic 4000 MiD to the Future Chemistry Flow Start EVO chemistry system. Specifically, the Hofmann rearrangement has been studied using the on-line mass spectrometry approach. Sample transfer from the flow reactor is achieved using a mass rate attenuator (MRA) and a sampling make-up flow from a high pressure pump. This enables the appropriate sample dilution, transfer, and preparation for electrospray ionization. The capability of this approach to provide process understanding is described using an industrial pharmaceutical process that is currently under development. The effect of a number of key experimental parameters, such as the composition of the sampling make-up flow and the dilution factor on the mass spectrometry data, is also discussed.
Farré, Maria José; Insa, Sara; Mamo, Julian; Barceló, Damià
2016-08-05
A new methodology based on on-line solid-phase extraction (SPE) ultra-high-performance-liquid chromatography coupled to a triple quadrupole mass spectrometer (UHPLC-MS-MS) for the determination of 15 individual anthropogenic N-nitrosodimethylamine (NDMA) precursors was developed. On-line SPE was performed by passing 2mL of the water sample through a Hypersil GOLD aQ column and chromatographic separation was done using a Kinetex Biphenyl column using methanol and 0.1% formic acid aqueous solution as a mobile phase. For unequivocal identification and confirmation, two selected reaction monitoring (SRM) transitions were monitored per compound. Quantification was performed by internal standard approach and matrix match calibration. The main advantages of the developed method are high sensitivity (limits of detection in the sub ng/L range), selectivity due to the use of tandem mass spectrometry, precision and minimum sample manipulation as well as fast analytical response. Process efficiency and recovery were also evaluated for all the target compounds. As part of the validation procedure, the method was applied in a sampling campaign for the analysis of influent and secondary effluent of a wastewater treatment plant (WWTP) in Girona, Spain. Additionally, the effluent from a nanofiltration (NF) membrane system used for water recycling was monitored. The percentage of NDMA formation explained by the measured precursors was also quantified. Copyright © 2016 Elsevier B.V. All rights reserved.
Final report on fiscal year 1992 activities for the environmental monitors line-loss study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenoyer, J.L.
The work performed on this Environmental Monitors Line-Loss Study has been performed under Contract Numbers MLW-SVV-073750 and MFH-SVV-207554. Work on the task was initiated mid-December 1991, and this report documents and summarizes the work performed through January 18, 1993. The sections included in this report summarize the work performed on the Environmental Monitors Line-Loss Study. The sections included in this report are arranged to reflect individual sub-tasks and include: descriptions of measurement systems and procedures used to obtain cascade impactor samples and laser spectrometer measurements from multiple stacks and locations; information on data acquisition, analyses, assessment, and software; discussion ofmore » the analyses and measurement results from the cascade impactor and laser spectrometer systems and software used; discussion on the development of general test methods and procedures for line-loss determinations; an overall summary and specific conclusions that can be made with regard to efforts performed on this task during FY 1992 and FY 1993. Supporting information for these sections is included in this report as appendices.« less
NASA Technical Reports Server (NTRS)
Briggs, Ryan M.; Frez, Clifford; Borgentun, Carl E.; Bagheri, Mahmood; Forouhar, Siamak; May, Randy D.
2014-01-01
Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.
Generic particulate-monitoring system for retrofit to Hanford exhaust stacks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Camman, J.W.; Carbaugh, E.H.
1982-11-01
Evaluations of 72 sampling and monitoring systems were performed at Hanford as the initial phase of a program to upgrade such systems. Each evaluation included determination of theoretical sampling efficiencies for particle sizes ranging from 0.5 to 10 micrometers aerodynamic equivalent diameter, addressing anisokinetic bias, sample transport line losses, and collector device efficiency. Upgrades needed to meet current Department of Energy guidance for effluent sampling and monitoring were identified, and a cost for each upgrade was estimated. A relative priority for each system's upgrade was then established based on evaluation results, current operational status, and future plans for the facilitymore » being exhausted. Common system upgrade requirements lead to the development of a generic design for common components of an exhaust stack sampling and monitoring system for airborne radioactive particulates. The generic design consists of commercially available off-the-shelf components to the extent practical and will simplify future stack sampling and monitoring system design, fabrication, and installation efforts. Evaluation results and their significance to system upgrades are empasized. A brief discussion of the analytical models used and experience to date with the upgrade program is included. Development of the generic stack sampling and monitoring system design is outlined. Generic system design features and limitations are presented. Requirements for generic system retrofitting to existing exhaust stacks are defined and benefits derived from generic system application are discussed.« less
Environmental microbial contamination in a stem cell bank.
Cobo, F; Concha, A
2007-04-01
The aim of this study was to evaluate the main environmental microbial contaminants of the clean rooms in our stem cell bank. We have measured the microbial air contamination by both passive and active air sampling and the microbial monitoring of surfaces by means of Rodac plates. The environmental monitoring tests were carried out in accordance with the guidelines of European Pharmacopeia and US Pharmacopeia. The micro-organisms were identified by means of an automated system (VITEK 2). During the monitoring, the clean rooms are continually under good manufacturing practices specifications. The most frequent contaminants were Gram-positive cocci. The main contaminants in our stem cell bank were coagulase-negative staphylococci and other opportunistic human pathogens. In order to assure the levels of potential contamination in both embryonic and adult stem cell lines, a continuous sampling of air particles and testing for viable microbiological contamination is necessary. This study is the first evaluation of the environmental contaminants in stem cell banks and can serve as initial evaluation for these establishments. The introduction of environmental monitoring programmes in the processing of stem cell lines could diminish the risk of contamination in stem cell cultures.
77 FR 27279 - Waybill Compliance Survey; Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-09
... waybills terminating on its lines. The information in the Waybill Sample is used to monitor traffic flows... Survey--information on carloads of traffic terminated each year by U.S. railroads--in order to determine...
Development of bunch shape monitor for high-intensity beam on the China ADS proton LINAC Injector II
NASA Astrophysics Data System (ADS)
Zhu, Guangyu; Wu, Junxia; Du, Ze; Zhang, Yong; Xue, Zongheng; Xie, Hongming; Wei, Yuan; Jing, Long; Jia, Huan
2018-05-01
The development, performance, and testing of the longitudinal bunch shape monitor, namely, the Fast Faraday Cup (FFC), are presented in this paper. The FFC is an invasive instrument controlled by a stepper motor, and its principle of operation is based on a strip line structure. The longitudinal bunch shape was determined by sampling a small part of the beam hitting the strip line through a 1-mm hole. The rise time of the detector reached 24 ps. To accommodate experiments that utilize high-intensity beams, the materials of the bunch shape monitor were chosen to sustain high temperatures. Water cooling was also integrated in the detector system to enhance heat transfer and prevent thermal damage. We also present an analysis of the heating caused by the beam. The bunch shape monitor has been installed and commissioned at the China ADS proton LINAC Injector II.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsiao, H.H.; Lai, C.C.; Chu, H.W.
A new method for on-line monitoring of total hydrocarbons and non-methane hydrocarbons in stack gas simultaneously was developed in this study. Based on the principle of on-line GC/FID, the method was developed and can be considered as a new modification of the Method 25 and 25A of US EPA. Major advantages of the method included (1) capability of distinguishing methane as Method 25; (2) near-real-time results; (3) broad species coverage; (4) monitoring methane in straightforward manner; (5) low operation and maintenance costs. In the proposed method, test samples were continuously pumped from detection sources and loaded with a two-loop samplingmore » valve. The samples were then injected into two GC columns-empty and molecular sieve columns. The empty column was used for detection of THC, and the molecular sieve column was for methane. The detector in this GC was FID. NMHC concentration was obtained by subtracting methane from THC. The tests were carried out to measure the THC and methane in waste gas in various industries, including surface coating, semiconductor manufacturing, synthetic leather industries. Recovery rates of THC in the samples were between 86% to 114% for about 100 m of transfer line of samples. For the standard gas, the recovery rate was about 101%, 6.6 % of measurement precision, and 88%--114% of accuracy. The results showed the promising and reliable measurement of the test method for THC and methane in waste gas.« less
Automated Sample Exchange Robots for the Structural Biology Beam Lines at the Photon Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiraki, Masahiko; Watanabe, Shokei; Yamada, Yusuke
2007-01-19
We are now developing automated sample exchange robots for high-throughput protein crystallographic experiments for onsite use at synchrotron beam lines. It is part of the fully automated robotics systems being developed at the Photon Factory, for the purposes of protein crystallization, monitoring crystal growth, harvesting and freezing crystals, mounting the crystals inside a hutch and for data collection. We have already installed the sample exchange robots based on the SSRL automated mounting system at our insertion device beam lines BL-5A and AR-NW12A at the Photon Factory. In order to reduce the time required for sample exchange further, a prototype ofmore » a double-tonged system was developed. As a result of preliminary experiments with double-tonged robots, the sample exchange time was successfully reduced from 70 seconds to 10 seconds with the exception of the time required for pre-cooling and warming up the tongs.« less
Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo
2012-07-01
Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.
NASA Astrophysics Data System (ADS)
Yuan, Shenfang; Chen, Jian; Yang, Weibo; Qiu, Lei
2017-08-01
Fatigue crack growth prognosis is important for prolonging service time, improving safety, and reducing maintenance cost in many safety-critical systems, such as in aircraft, wind turbines, bridges, and nuclear plants. Combining fatigue crack growth models with the particle filter (PF) method has proved promising to deal with the uncertainties during fatigue crack growth and reach a more accurate prognosis. However, research on prognosis methods integrating on-line crack monitoring with the PF method is still lacking, as well as experimental verifications. Besides, the PF methods adopted so far are almost all sequential importance resampling-based PFs, which usually encounter sample impoverishment problems, and hence performs poorly. To solve these problems, in this paper, the piezoelectric transducers (PZTs)-based active Lamb wave method is adopted for on-line crack monitoring. The deterministic resampling PF (DRPF) is proposed to be used in fatigue crack growth prognosis, which can overcome the sample impoverishment problem. The proposed method is verified through fatigue tests of attachment lugs, which are a kind of important joint component in aerospace systems.
Corrosion probe. Innovative technology summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Over 253 million liters of high-level waste (HLW) generated from plutonium production is stored in mild steel tanks at the Department of Energy (DOE) Hanford Site. Corrosion monitoring of double-shell storage tanks (DSTs) is currently performed at Hanford using a combination of process knowledge and tank waste sampling and analysis. Available technologies for corrosion monitoring have progressed to a point where it is feasible to monitor and control corrosion by on-line monitoring of the corrosion process and direct addition of corrosion inhibitors. The electrochemical noise (EN) technique deploys EN-based corrosion monitoring probes into storage tanks. This system is specifically designedmore » to measure corrosion rates and detect changes in waste chemistry that trigger the onset of pitting and cracking. These on-line probes can determine whether additional corrosion inhibitor is required and, if so, provide information on an effective end point to the corrosion inhibitor addition procedure. This report describes the technology, its performance, its application, costs, regulatory and policy issues, and lessons learned.« less
75 FR 29812 - Notice and Request for Comments; Waybill Compliance Survey
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
... waybills terminating on its lines. The information in the Waybill Sample is used to monitor traffic flows... Survey--information on carloads of traffic terminated each year by U.S. railroads--in order to determine...
... on an outpatient basis. You will be positioned on the examining table. You may be connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A nurse or technologist will insert an intravenous (IV) line into a ...
In-line localized monitoring of catalyst activity in selective catalytic NO.sub.x reduction systems
Muzio, Lawrence J [Laguna Niguel, CA; Smith, Randall A [Huntington Beach, CA
2009-12-22
Localized catalyst activity in an SCR unit for controlling emissions from a boiler, power plant, or any facility that generates NO.sub.x-containing flue gases is monitored by one or more modules that operate on-line without disrupting the normal operation of the facility. Each module is positioned over a designated lateral area of one of the catalyst beds in the SCR unit, and supplies ammonia, urea, or other suitable reductant to the catalyst in the designated area at a rate that produces an excess of the reductant over NO.sub.x on a molar basis through the designated area. Sampling probes upstream and downstream of the designated area draw samples of the gas stream for NO.sub.x analysis, and the catalyst activity is determined from the difference in NO.sub.x levels between the two probes.
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils.
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-03-14
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring.
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-01-01
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring. PMID:28335436
Theoretical and experimental separation dynamics in capillary zone electrophoresis
NASA Technical Reports Server (NTRS)
Thormann, Wolfgang; Michaud, Jon-Pierre; Mosher, Richard A.
1986-01-01
The mathematical model of Bier et al. (1983) is used in a computer aided analysis of the conditions in capillary zone electrophoresis (ZE) under which sample zones migrate noninteractively with the carrier electrolyte. The monitoring of sample zones with a capillary analyzer that features both on-line conductivity and UV detection at the end of the separation trough is discussed. Data from a ZE analysis of a 5-component mixture are presented, and it is noted that all five components can be monitored via their conductivity change if enough sample is present. It is suggested from the results that the concentration ratio of background buffer to sample should be a minimum of 100:1 to effectively apply the plate concept to ZE.
Carvalho, Maria L; Doma, Jemimah; Sztyler, Magdalena; Beech, Iwona; Cristiani, Pierangela
2014-06-01
The present paper reports the on-line monitoring of corrosion behavior of the CuNi 70:30 and Al brass alloys exposed to seawater and complementary offline microbiological analyses. An electrochemical equipment with sensors specifically set for industrial application and suitable to estimate the corrosion (by linear polarization resistance technique), the biofilm growth (by the BIOX electrochemical probe), the chlorination treatment and other physical-chemical parameters of the water has been used for the on-line monitoring. In order to identify and better characterize the bacteria community present on copper alloys, tube samples were collected after a long period (1year) and short period (2days) of exposition to treated natural seawater (TNSW) and natural seawater (NSW). From the collected samples, molecular techniques such as DNA extraction, polymerase chain reaction (PCR), denaturing gradient gel electrophoresis (DGGE) and identification by sequencing were performed to better characterize and identify the microbial biodiversity present in the samples. The monitoring data confirmed the significant role played by biofouling deposition against the passivity of these Cu alloys in seawater and the positive influence of antifouling treatments based on low level dosages. Molecular analysis indicated biodiversity with the presence of Marinobacter, Alteromonas and Pseudomonas species. Copyright © 2013 Elsevier B.V. All rights reserved.
Scott, David E.; Willis, Sean D.; Gabbert, Seth; Johnson, Dave A.; Naylor, Erik; Janle, Elsa M.; Krichevsky, Janice E.; Lunte, Craig E.; Lunte, Susan M.
2015-01-01
The development of an on-animal separation-based sensor that can be employed for monitoring drug metabolism in a freely roaming sheep is described. The system consists of microdialysis sampling coupled directly to microchip electrophoresis with electrochemical detection (MD-ME-EC). Separations were accomplished using an all-glass chip with integrated platinum working and reference electrodes. Discrete samples from the microdialysis flow were introduced into the electrophoresis chip using a flow-gated injection approach. Electrochemical detection was accomplished in-channel using a two-electrode isolated potentiostat. Nitrite was separated by microchip electrophoresis using reverse polarity and a run buffer consisting of 50 mM phosphate at pH 7.4. The entire system was under telemetry control. The system was first tested with rats to monitor the production of nitrite following introduction of nitroglycerin into the subdermal tissue using a linear probe. The data acquired using the on-line MD-ME-EC system was compared to that obtained off-line analysis by liquid chromatography with electrochemical detection (LC-EC), using a second microdialysis probe implanted parallel to the first probe in the same animal. The MD-ME-EC device was then used on-animal to monitor the subdermal metabolism of nitroglycerin in sheep. The ultimate goal is to use this device to simultaneously monitor drug metabolism and behavior in a freely roaming animal. PMID:25697221
Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M
2014-01-03
Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA JSC water monitor system: City of Houston field demonstration
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.
1979-01-01
A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.
Prevalence of genetically modified rice, maize, and soy in Saudi food products.
Elsanhoty, Rafaat M; Al-Turki, A I; Ramadan, Mohamed Fawzy
2013-10-01
Qualitative and quantitative DNA-based methods were applied to detect genetically modified foods in samples from markets in the Kingdom of Saudi Arabia. Two hundred samples were collected from Al-Qassim, Riyadh, and Mahdina in 2009 and 2010. GMOScreen 35S and NOS test kits for the detection of genetically modified organism varieties in samples were used. The positive results obtained from GMOScreen 35S and NOS were identified using specific primer pairs. The results indicated that all rice samples gave negative results for the presence of 35S and NOS terminator. About 26 % of samples containing soybean were positive for 35S and NOS terminator and 44 % of samples containing maize were positive for the presence of 35S and/or NOS terminator. The results showed that 20.4 % of samples was positive for maize line Bt176, 8.8 % was positive for maize line Bt11, 8.8 % was positive for maize line T25, 5.9 % was positive for maize line MON 810, and 5.9 % was positive for StarLink maize. Twelve samples were shown to contain <3 % of genetically modified (GM) soy and 6 samples >10 % of GM soy. Four samples containing GM maize were shown to contain >5 % of GM maize MON 810. Four samples containing GM maize were shown to contain >1 % of StarLink maize. Establishing strong regulations and certified laboratories to monitor GM foods or crops in Saudi market is recommended.
Gomo, Zvenyika Ar; Hakim, James G; Walker, Sarah A; Tinago, Willard; Mandozana, Gibson; Kityo, Cissy; Munderi, Paula; Katabira, Elly; Reid, Andrew; Gibb, Diana M; Gilks, Charles F
2014-01-01
Increasing numbers of HIV-infected patients in sub-Saharan Africa are exposed to antiretroviral therapy (ART), but there are few data on lipid changes on first-line ART, and even fewer on second-line. DART was a randomized trial comparing monitoring strategies in Ugandan/Zimbabwean adults initiating first-line ART and switching to second-line at clinical/immunological failure. We evaluated fasting lipid profiles at second-line initiation and ≥48 weeks subsequently in stored samples from Zimbabwean patients switching before 18 September 2006. Of 91 patients switched to second-line ART, 65(73%) had fasting samples at switch and ≥48 weeks, 14(15%) died or were lost <48 weeks, 10(11%) interrupted ART for >14 days and 2(2%) had no samples available. 56/65(86%) received ZDV/d4T + 3TC + TDF first-line, 6(9%) ZDV/d4T + 3TC + NVP and 3(5%) ZDV + 3TC with TDF and NVP. Initial second-line regimens were LPV/r + NNRTI in 27(41%), LPV/r + NNRTI + ddI in 33(50%) and LPV/r + TDF + ddI/3TC/ZDV in 6(9%). At second-line initiation median (IQR) TC, LDL-C, HDL-C and TG (mmol/L) were 3.3(2.8-4.0), 1.7(1.3-2.2), 0.7(0.6-0.9) and 1.1(0.8-1.9) respectively. Levels were significantly increased 48 weeks later, by mean (SE) +2.0(0.1), +1.1(0.1), +0.5(0.05) and +0.4(0.2) respectively (p < 0.001; TG p = 0.01). 3% at switch vs 25% 48 weeks later had TC >5.2 mmol/L; 3% vs 25% LDL-C >3.4 mmol/L and 91% vs 41% HDL-C <1.1 mmol/L (p < 0.001). Similar proportions had TG >1.8 mmol/L (0 vs 3%) and TC/HDL-C ≥5 (40% vs 33%) (p > 0.15). Modest lipid elevations were observed in African patients on predominantly LPV/r + NNRTI-based second-line regimens. Routine lipid monitoring during second-line ART regimens may not be warranted in this setting but individual cardiovascular risk assessment should guide practice.
THE SLOAN DIGITAL SKY SURVEY REVERBERATION MAPPING PROJECT: TECHNICAL OVERVIEW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Yue; Brandt, W. N.; Dawson, Kyle S.
2015-01-01
The Sloan Digital Sky Survey Reverberation Mapping (SDSS-RM) project is a dedicated multi-object RM experiment that has spectroscopically monitored a sample of 849 broad-line quasars in a single 7 deg{sup 2} field with the SDSS-III Baryon Oscillation Spectroscopic Survey spectrograph. The RM quasar sample is flux-limited to i {sub psf} = 21.7 mag, and covers a redshift range of 0.1 < z < 4.5 without any other cuts on quasar properties. Optical spectroscopy was performed during 2014 January-July dark/gray time, with an average cadence of ∼4 days, totaling more than 30 epochs. Supporting photometric monitoring in the g and i bandsmore » was conducted at multiple facilities including the Canada-France-Hawaii Telescope (CFHT) and the Steward Observatory Bok telescope in 2014, with a cadence of ∼2 days and covering all lunar phases. The RM field (R.A., decl. = 14:14:49.00, +53:05:00.0) lies within the CFHT-LS W3 field, and coincides with the Pan-STARRS 1 (PS1) Medium Deep Field MD07, with three prior years of multi-band PS1 light curves. The SDSS-RM six month baseline program aims to detect time lags between the quasar continuum and broad line region (BLR) variability on timescales of up to several months (in the observed frame) for ∼10% of the sample, and to anchor the time baseline for continued monitoring in the future to detect lags on longer timescales and at higher redshift. SDSS-RM is the first major program to systematically explore the potential of RM for broad-line quasars at z > 0.3, and will investigate the prospects of RM with all major broad lines covered in optical spectroscopy. SDSS-RM will provide guidance on future multi-object RM campaigns on larger scales, and is aiming to deliver more than tens of BLR lag detections for a homogeneous sample of quasars. We describe the motivation, design, and implementation of this program, and outline the science impact expected from the resulting data for RM and general quasar science.« less
Measurements of nitrous oxide emissions from P.F. fired power stations
NASA Astrophysics Data System (ADS)
Sloan, S. A.; Laird, C. K.
Nitrous oxide (N 2O) was measured in the flue gas from four wall-fired and three corner-fired 500 MW boilers, fitted with either conventional or low-NO x burners, at four C.E.G.B. power stations. Measurements were made both by on-line non-dispersive infra red (NDIR) monitors and by extractive sampling for later laboratory analysis by electron capture gas chromatography (ECD GC). It was found that the on-line and laboratory methods were in good agreement for samples analyzed within 1-3 h of sampling, but that the nitrous oxide concentration in the stored samples had a tendency to increase with time, which was dependent on the concentration of water in the sample. Experiments with synthetic mixtures showed that the increase in nitrous oxide concentration was consistent with the overall reaction2NO+SO 2→N 2O+SO 3 in which nitric oxide is reduced by sulphur dioxide. The highest average N 2O concentration measured by the on-line analyzer was 16 vpm, and for most of the boilers monitored the concentration was less than 10 vpm. There was no statistically significant difference between the measured N 2O emissions from normal boilers and those fitted with low-NO x burners. It is suggested that these values are close to the true levels of N 2O emissions from p.f. fired boilers and that recent reports of high levels (up to 200 vpm) are likely to be an artefact resulting from the observed generation of N 2O in stored samples. A consequence of these measurements of N 2O is that current estimates of the contribution of emissions from p.f. fired boilers to the global N 2O budget are likely to be too high.
On-line condition monitoring applications in nuclear power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hastiemian, H. M.; Feltus, M. A.
2006-07-01
Existing signals from process instruments in nuclear power plants can be sampled while the plant is operating and analyzed to verify the static and dynamic performance of process sensors, identify process-to-sensor problems, detect instrument anomalies such as venturi fouling, measure the vibration of the reactor vessel and its internals, or detect thermal hydraulic anomalies within the reactor coolant system. These applications are important in nuclear plants to satisfy a variety of objectives such as: 1) meeting the plant technical specification requirements; 2) complying with regulatory regulations; 3) guarding against equipment and process degradation; 4) providing a means for incipient failuremore » detection and predictive maintenance; or 5) identifying the root cause of anomalies in equipment and plant processes. The technologies that are used to achieve these objectives are collectively referred to as 'on-line condition monitoring.' This paper presents a review of key elements of these technologies, provides examples of their use in nuclear power plants, and illustrates how they can be integrated into an on-line condition monitoring system for nuclear power plants. (authors)« less
An on-line reactivity and power monitor for a TRIGA reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binney, Stephen E.; Bakir, Alia J.
1988-07-01
As the personal computer (PC) becomes more and more of a significant influence on modern technology, it is reasonable that at some point in time they would be used to interface with TRIGA reactors. A personal computer with a special interface board has been used to monitor key parameters during operation of the Oregon State University TRIGA Reactor (OSTR). A description of the apparatus used and sample results are included.
MicroRaman measurements for nuclear fuel reprocessing applications
Casella, Amanda; Lines, Amanda; Nelson, Gilbert; ...
2016-12-01
Treatment and reuse of used nuclear fuel is a key component in closing the nuclear fuel cycle. Solvent extraction reprocessing methods that have been developed contain various steps tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper willmore » focus on the development and application of a new MicroRaman probe for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid in solutions relevant to used nuclear fuel reprocessing. Previous research has successfully demonstrated the applicability on the macroscopic scale, using sample probes requiring larger solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 μL or less, which is a scale reduction of over 1,000 fold in sample size. Finally, this paper will summarize our current work in this area including: comparisons between the macroscopic and microscopic probes for detection limits, optimized channel focusing, and application in a flow cell with varying levels of HNO 3, and UO 2(NO 3) 2.« less
Observational selection biases in time-delay strong lensing and their impact on cosmography
NASA Astrophysics Data System (ADS)
Collett, Thomas E.; Cunnington, Steven D.
2016-11-01
Inferring cosmological parameters from time-delay strong lenses requires a significant investment of telescope time; it is therefore tempting to focus on the systems with the brightest sources, the highest image multiplicities and the widest image separations. We investigate if this selection bias can influence the properties of the lenses studied and the cosmological parameters inferred. Using an ellipsoidal power-law deflector population, we build a sample of double- and quadruple-image systems. Assuming reasonable thresholds on image separation and flux, based on current lens monitoring campaigns, we find that the typical density profile slopes of monitorable lenses are significantly shallower than the input ensemble. From a sample of quads, we find that this selection function can introduce a 3.5 per cent bias on the inferred time-delay distances if the properties of the input ensemble are (incorrectly) used as priors on the lens model. This bias remains at the 2.4 per cent level when high-resolution imaging of the quasar host is used to precisely infer the properties of individual lenses. We also investigate if the lines of sight for monitorable strong lenses are biased. The expectation value for the line-of-sight convergence is increased by 0.009 (0.004) for quads (doubles) implying a 0.9 per cent (0.4 per cent) bias on H0. We therefore conclude that whilst the properties of typical quasar lenses and their lines of sight do deviate from the global population, the total magnitude of this effect is likely to be a subdominant effect for current analyses, but has the potential to be a major systematic for samples of ˜25 or more lenses.
A prototype gas exchange monitor for exercise stress testing aboard NASA Space Station
NASA Technical Reports Server (NTRS)
Orr, Joseph A.; Westenskow, Dwayne R.; Bauer, Anne
1989-01-01
This paper describes an easy-to-use monitor developed to track the weightlessness deconditioning aboard the NASA Space Station, together with the results of testing of a prototype instrument. The monitor measures the O2 uptake and CO2 production, and calculates the maximum O2 uptake and anaerobic threshold during an exercise stress test. The system uses two flowmeters in series to achieve a completely automatic calibration, and uses breath-by-breath compensation for sample line-transport delay. The monitor was evaluated using two laboratory methods and was shown to be accurate. The system's block diagram and the bench test setup diagram are included.
Woolfenden, Elizabeth
2010-04-16
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents current state-of-the-art and recent developments in relevant areas such as sorbent research, sampler design, enhanced approaches to analytical quality assurance and on-tube derivatisation. Copyright 2009 Elsevier B.V. All rights reserved.
Currens, J.C.
1999-01-01
Analytical data for nitrate and triazines from 566 samples collected over a 3-year period at Pleasant Grove Spring, Logan County, KY, were statistically analyzed to determine the minimum data set needed to calculate meaningful yearly averages for a conduit-flow karst spring. Results indicate that a biweekly sampling schedule augmented with bihourly samples from high-flow events will provide meaningful suspended-constituent and dissolved-constituent statistics. Unless collected over an extensive period of time, daily samples may not be representative and may also be autocorrelated. All high-flow events resulting in a significant deflection of a constituent from base-line concentrations should be sampled. Either the geometric mean or the flow-weighted average of the suspended constituents should be used. If automatic samplers are used, then they may be programmed to collect storm samples as frequently as every few minutes to provide details on the arrival time of constituents of interest. However, only samples collected bihourly should be used to calculate averages. By adopting a biweekly sampling schedule augmented with high-flow samples, the need to continuously monitor discharge, or to search for and analyze existing data to develop a statistically valid monitoring plan, is lessened.Analytical data for nitrate and triazines from 566 samples collected over a 3-year period at Pleasant Grove Spring, Logan County, KY, were statistically analyzed to determine the minimum data set needed to calculate meaningful yearly averages for a conduit-flow karst spring. Results indicate that a biweekly sampling schedule augmented with bihourly samples from high-flow events will provide meaningful suspended-constituent and dissolved-constituent statistics. Unless collected over an extensive period of time, daily samples may not be representative and may also be autocorrelated. All high-flow events resulting in a significant deflection of a constituent from base-line concentrations should be sampled. Either the geometric mean or the flow-weighted average of the suspended constituents should be used. If automatic samplers are used, then they may be programmed to collect storm samples as frequently as every few minutes to provide details on the arrival time of constituents of interest. However, only samples collected bihourly should be used to calculate averages. By adopting a biweekly sampling schedule augmented with high-flow samples, the need to continuously monitor discharge, or to search for and analyze existing data to develop a statistically valid monitoring plan, is lessened.
Rugged large volume injection for sensitive capillary LC-MS environmental monitoring
NASA Astrophysics Data System (ADS)
Roberg-Larsen, Hanne; Abele, Silvija; Demir, Deniz; Dzabijeva, Diana; Amundsen, Sunniva F.; Wilson, Steven R.; Bartkevics, Vadims; Lundanes, Elsa
2017-08-01
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05 - 12.5 ng/L range. Between-day and within-day repeatability of selected analytes were < 20% RSD.
Application of laser-induced breakdown spectroscopy to zirconium in aqueous solution
NASA Astrophysics Data System (ADS)
Ruas, Alexandre; Matsumoto, Ayumu; Ohba, Hironori; Akaoka, Katsuaki; Wakaida, Ikuo
2017-05-01
In the context of the Fukushima Dai-ichi Nuclear Power Plant (F1-NPP) decommissioning process, laser-induced breakdown spectroscopy (LIBS) has many advantages. The purpose of the present work is to demonstrate the on-line monitoring capability of the LIBS coupled with the ultra-thin liquid jet sampling method. The study focuses on zirconium in aqueous solution, considering that it is a major element in the F1-NPP fuel debris that has been subject to only a few LIBS studies in the past. The methodology of data acquisition and processing are described. In particular, two regions of interest with many high intensity zirconium lines have been observed around 350 nm in the case of the ionic lines and 478 nm in the case of atomic lines. The best analytical conditions for zirconium are different depending on the analysis of ionic lines or atomic lines. A low LOD of about 4 mg L- 1 could be obtained, showing that LIBS coupled with the ultra-thin liquid jet sampling technique is a promising alternative for more complex solutions found in the F1-NPP, namely mixtures containing zirconium.
Tryland, Ingun; Eregno, Fasil Ejigu; Braathen, Henrik; Khalaf, Goran; Sjølander, Ingrid; Fossum, Marie
2015-02-04
The fully automated Colifast ALARM™ has been used for two years for daily monitoring of the presence/absence of Escherichia coli in 100 mL raw water at Oset drinking water treatment plant in Oslo, Norway. The raw water is extracted from 35 m depth from the Lake Maridalsvannet. E. coli was detected in 18% of the daily samples. In general, most samples positive for E. coli were observed during the autumn turnover periods, but even in some samples taken during warm and dry days in July, with stable temperature stratification in the lake, E. coli was detected. The daily samples gave useful additional information compared with the weekly routine samples about the hygienic raw water quality and the hygienic barrier efficiency of the lake under different weather conditions and seasons. The winter 2013/2014 was much warmer than the winter 2012/2013. The monitoring supported the hypothesis that warmer winters with shorter periods with ice cover on lakes, which may be a consequence of climate changes, may reduce the hygienic barrier efficiency in deep lakes used as drinking water sources.
The potential of on-line continuous leach ICP-MS analysis for linking trace elements to mineralogy
NASA Astrophysics Data System (ADS)
Roskam, Gerlinde; Verheul, Marc; Moraetis, Daniel; Giannakis, George; van Gaans, Pauline
2014-05-01
A set of five soil samples was subjected to an on-line continuous leach inductively coupled plasma mass spectrometry experiment, with progressively reactive solvents (0.01M CaCl2, 0.1 M HNO3, 1M HNO3, 4M HNO3) Each sample was packed in a quartz tube (Ø= 1 cm, length 2 cm) and diluted 1:1 with acid washed quartz to prevent clogging. The gas that was produced during the extraction was removed by leading the effluent into a small container, from where the sample was directly pumped into the ICP-MS. 115In was used as an internal standard. Continuous leach experiments have the advantage of real time (every 2 seconds) full elemental analysis. Mineral breakdown reactions can be monitored via the major elements. The trace elements associated with the minerals are monitored simultaneously, thus eliminating the uncertainties of host mineral-trace element combinations in traditional off-line sequential extractions. The continuous leach experimental data are correlated to XRD-results for mineralogy and total elemental concentrations. The soil samples used were collected from different sites in the Koiliaris River watershed, Crete, Greece 1). The selection of the sites was based on variability in bedrock (limestone, metamorphic and alluvial sediments) and current land use (grape farming, olive trees). Soils were sampled at two depths: at the surface and just above the bedrock. No large differences in the major elements between the two depths were measured. To provide background to the on-line sequential data, also total concentrations of the major elements were analysed by XRF and the mineralogy was analysed by XRD. The fraction <2mm was sieved and digested with HF, HClO4 and HNO3 for additional trace element analysis. 1) See related abstract Roskam et al., 2014: REE profiles in continuous leach ICP-MS (CL-ICP-MS) experiments in soil, linked to REE profiles in surface water in the Koiliaris River Critical Zone Observatory (CZO), Crete, Greece.
Visual detection of multiple genetically modified organisms in a capillary array.
Shao, Ning; Chen, Jianwei; Hu, Jiaying; Li, Rong; Zhang, Dabing; Guo, Shujuan; Hui, Junhou; Liu, Peng; Yang, Litao; Tao, Sheng-Ce
2017-01-31
There is an urgent need for rapid, low-cost multiplex methodologies for the monitoring of genetically modified organisms (GMOs). Here, we report a C[combining low line]apillary A[combining low line]rray-based L[combining low line]oop-mediated isothermal amplification for M[combining low line]ultiplex visual detection of nucleic acids (CALM) platform for the simple and rapid monitoring of GMOs. In CALM, loop-mediated isothermal amplification (LAMP) primer sets are pre-fixed to the inner surface of capillaries. The surface of the capillary array is hydrophobic while the capillaries are hydrophilic, enabling the simultaneous loading and separation of the LAMP reaction mixtures into each capillary by capillary forces. LAMP reactions in the capillaries are then performed in parallel, and the results are visually detected by illumination with a hand-held UV device. Using CALM, we successfully detected seven frequently used transgenic genes/elements and five plant endogenous reference genes with high specificity and sensitivity. Moreover, we found that measurements of real-world blind samples by CALM are consistent with results obtained by independent real-time PCRs. Thus, with an ability to detect multiple nucleic acids in a single easy-to-operate test, we believe that CALM will become a widely applied technology in GMO monitoring.
Monitoring AGNs with Hbeta Asymmetry with the Wyoming Infra-Red Observatory
NASA Astrophysics Data System (ADS)
Brotherton, Michael S.; Du, Pu; Wang, Jian-Min; Wang, Kai; Huang, Zhengpeng; Hu, Chen; Li, Yan-rong; Kasper, David H.; Chick, William T.; Nguyen, My L.; Maithil, Jaya; Hand, Derek; Bai, Jin-Ming; Ho, Luis
2018-06-01
We present preliminary results from two seasons of reverberation mapping of AGNs using the optical longslit spectrograph on the 2.3 meter WIRO telescope. The majority of the sample is part of our "Monitoring AGNs with Hbeta Asymmetry" project, also known as MAHA, which targets rarer AGNs with extremely asymmetric profiles that may provide new insights into the full diversity of size and structure of the broad-line region (BLR). Our hundreds of nights of telescope time provide dozens of epochs of spectra for approximately two dozen objects. Notably we find that many AGNs with broader asymmetric Hbeta emission lines possess time lags significantly shorter than expected for their luminosity in comparison to the majority of AGNs reverberation mapped.
NASA Astrophysics Data System (ADS)
Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.
2000-03-01
The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.
Understanding Characteristics of Families Who Buy Local Produce
ERIC Educational Resources Information Center
Racine, Elizabeth F.; Mumford, Elizabeth A.; Laditka, Sarah B.; Lowe, Anna E.
2013-01-01
Objective: To examine individual characteristics associated with local produce purchasing among North Carolina families with children. Design: Cross-sectional analysis using data from the 2008 North Carolina Child Health Assessment and Monitoring Program (NC CHAMP), a representative sample of adults who have land-line telephones. Setting: North…
Air-coupled ultrasound: a novel technique for monitoring the curing of thermosetting matrices.
Lionetto, Francesca; Tarzia, Antonella; Maffezzoli, Alfonso
2007-07-01
A custom-made, air-coupled ultrasonic device was applied to cure monitoring of thick samples (7-10 mm) of unsaturated polyester resin at room temperature. A key point was the optimization of the experimental setup in order to propagate compression waves during the overall curing reaction by suitable placement of the noncontact transducers, placed on the same side of the test material, in the so-called pitch-catch configuration. The progress of polymerization was monitored through the variation of the time of flight of the propagating longitudinal waves. The exothermic character of the polymerization was taken into account by correcting the measured value of time of flight with that one in air, obtained by sampling the air velocity during the experiment. The air-coupled ultrasonic results were compared with those obtained from conventional contact ultrasonic measurements. The good agreement between the air-coupled ultrasonic results and those obtained by the rheological analysis demonstrated the reliability of air-coupled ultrasound in monitoring the changes of viscoelastic properties at gelation and vitrification. The position of the transducers on the same side of the sample makes this technique suitable for on-line cure monitoring during several composite manufacturing technologies.
Olofsson, Madelen A; Bylund, Dan
2015-10-01
A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurley, D.F.; Whitehouse, J.M.
A dedicated low-flow groundwater sample collection system was designed for implementation in a post-closure ACL monitoring program at the Yaworski Lagoon NPL site in Canterbury, Connecticut. The system includes dedicated bladder pumps with intake ports located in the screened interval of the monitoring wells. This sampling technique was implemented in the spring of 1993. The system was designed to simultaneously obtain samples directly from the screened interval of nested wells in three distinct water bearing zones. Sample collection is begun upon stabilization of field parameters. Other than line volume, no prior purging of the well is required. It was foundmore » that dedicated low-flow sampling from the screened interval provides a method of representative sample collection without the bias of suspended solids introduced by traditional techniques of pumping and bailing. Analytical data indicate that measured chemical constituents are representative of groundwater migrating through the screened interval. Upon implementation of the low-flow monitoring system, analytical results exhibited a decrease in concentrations of some organic compounds and metals. The system has also proven to be a cost effective alternative to pumping and bailing which generate large volumes of purge water requiring containment and disposal.« less
Gormley, Andrew M.; Forsyth, David M.; Wright, Elaine F.; Lyall, John; Elliott, Mike; Martini, Mark; Kappers, Benno; Perry, Mike; McKay, Meredith
2015-01-01
There is interest in large-scale and unbiased monitoring of biodiversity status and trend, but there are few published examples of such monitoring being implemented. The New Zealand Department of Conservation is implementing a monitoring program that involves sampling selected biota at the vertices of an 8-km grid superimposed over the 8.6 million hectares of public conservation land that it manages. The introduced brushtail possum (Trichosurus Vulpecula) is a major threat to some biota and is one taxon that they wish to monitor and report on. A pilot study revealed that the traditional method of monitoring possums using leg-hold traps set for two nights, termed the Trap Catch Index, was a constraint on the cost and logistical feasibility of the monitoring program. A phased implementation of the monitoring program was therefore conducted to collect data for evaluating the trade-off between possum occupancy–abundance estimates and the costs of sampling for one night rather than two nights. Reducing trapping effort from two nights to one night along four trap-lines reduced the estimated costs of monitoring by 5.8% due to savings in labour, food and allowances; it had a negligible effect on estimated national possum occupancy but resulted in slightly higher and less precise estimates of relative possum abundance. Monitoring possums for one night rather than two nights would provide an annual saving of NZ$72,400, with 271 fewer field days required for sampling. Possums occupied 60% (95% credible interval; 53–68) of sampling locations on New Zealand’s public conservation land, with a mean relative abundance (Trap Catch Index) of 2.7% (2.0–3.5). Possum occupancy and abundance were higher in forest than in non-forest habitats. Our case study illustrates the need to evaluate relationships between sampling design, cost, and occupancy–abundance estimates when designing and implementing large-scale occupancy–abundance monitoring programs. PMID:26029890
Józwa, Wojciech; Czaczyk, Katarzyna
2012-04-02
Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.
Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis
NASA Technical Reports Server (NTRS)
Arkin, C.; Gillespie, Stacey; Ratzel, Christopher
2010-01-01
A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.
In-Line Monitoring of a Pharmaceutical Pan Coating Process by Optical Coherence Tomography.
Markl, Daniel; Hannesschläger, Günther; Sacher, Stephan; Leitner, Michael; Buchsbaum, Andreas; Pescod, Russel; Baele, Thomas; Khinast, Johannes G
2015-08-01
This work demonstrates a new in-line measurement technique for monitoring the coating growth of randomly moving tablets in a pan coating process. In-line quality control is performed by an optical coherence tomography (OCT) sensor allowing nondestructive and contact-free acquisition of cross-section images of film coatings in real time. The coating thickness can be determined directly from these OCT images and no chemometric calibration models are required for quantification. Coating thickness measurements are extracted from the images by a fully automated algorithm. Results of the in-line measurements are validated using off-line OCT images, thickness calculations from tablet dimension measurements, and weight gain measurements. Validation measurements are performed on sample tablets periodically removed from the process during production. Reproducibility of the results is demonstrated by three batches produced under the same process conditions. OCT enables a multiple direct measurement of the coating thickness on individual tablets rather than providing the average coating thickness of a large number of tablets. This gives substantially more information about the coating quality, that is, intra- and intertablet coating variability, than standard quality control methods. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Adams, C G; McGhee, P S; Schenker, J H; Gut, L J; Miller, J R
2017-08-01
This field study of codling moth, Cydia pomonella (L.), response to single versus multiple monitoring traps baited with codlemone demonstrates that precision of a given capture number is alarmingly poor when the population is held constant by releasing moths. Captures as low as zero and as high as 12 males per single trap are to be expected where the catch mode is three. Here, we demonstrate that the frequency of false negatives and overestimated positives for codling moth trapping can be substantially reduced by employing the tactic of line-trapping, where five traps were deployed 4 m apart along a row of apple trees. Codling moth traps spaced closely competed only slightly. Therefore, deploying five traps closely in a line is a sampling technique nearly as good as deploying five traps spaced widely. But line trapping offers a substantial savings in time and therefore cost when servicing aggregated versus distributed traps. As the science of pest management matures by mastering the ability to translate capture numbers into estimates of absolute pest density, it will be important to employ a tactic like line-trapping so as to shrink the troublesome variability associated with capture numbers in single traps that thwarts accurate decisions about if and when to spray. Line-trapping might similarly increase the reliability and utility of density estimates derived from capture numbers in monitoring traps for various pest and beneficial insects. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America.
33 CFR 157.12d - Technical specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pipe runs full of liquid at all times during the discharge of the effluent. Sampling probes must... line as appropriate, so as to be always filled with the liquid being discharged. (2) A flow meter must... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and...
33 CFR 157.12d - Technical specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pipe runs full of liquid at all times during the discharge of the effluent. Sampling probes must... line as appropriate, so as to be always filled with the liquid being discharged. (2) A flow meter must... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and...
NASA Astrophysics Data System (ADS)
Stadler, Hermann; Skritek, Paul; Zerobin, Wolfgang; Klock, Erich; Farnleitner, Andreas H.
2010-05-01
In the last year, global changes in ecosystems, the growth of population, and modifications of the legal framework within the EU have caused an increased need of qualitative groundwater and spring water monitoring with the target to continue to supply the consumers with high-quality drinking water in the future. Additionally the demand for sustainable protection of drinking water resources effected the initiated implementation of early warning systems and quality assurance networks in water supplies. In the field of hydrogeological investigations, event monitoring and event sampling is worst case scenario monitoring. Therefore, such tools become more and more indispensible to get detailed information about aquifer parameter and vulnerability. In the framework of water supplies, smart sampling designs combined with in-situ measurements of different parameters and on-line access can play an important role in early warning systems and quality surveillance networks. In this study nested sampling tiers are presented, which were designed to cover total system dynamic. Basic monitoring sampling (BMS), high frequency sampling (HFS) and automated event sampling (AES) were combined. BMS was organized with a monthly increment for at least two years, and HFS was performed during times of increased groundwater recharge (e.g. during snowmelt). At least one AES tier was embedded in this system. AES was enabled by cross-linking of hydrological stations, so the system could be run fully automated and could include real-time availability of data. By means of networking via Low Earth Orbiting Satellites (LEO-satellites), data from the precipitation station (PS) in the catchment area are brought together with data from the spring sampling station (SSS) without the need of terrestrial infrastructure for communication and power supply. Furthermore, the whole course of input and output parameters, like precipitation (input system) and discharge (output system), and the status of the sampling system is transmitted via LEO-Satellites to a Central Monitoring Station (CMS), which can be linked with a web-server to have unlimited real-time data access. The automatically generated notice of event to a local service team of the sampling station is transmitted in combination with internet, GSM, GPRS or LEO-Satellites. If a GPRS-network is available for the stations, this system could be realized also via this network. However, one great problem of these terrestrial communication systems is the risk of default when their networks are overloaded, like during flood events or thunderstorms. Therefore, in addition, it is necessary to have the possibility to transmit the measured values via communication satellites when a terrestrial infrastructure is not available. LEO-satellites are especially useful in the alpine regions because they have no deadspots, but only sometimes latency periods. In the workouts we combined in-situ measurements (precipitation, electrical conductivity, discharge, water temperature, spectral absorption coefficient, turbidity) with time increments from 1 to 15 minutes with data from the different sampling tires (environmental isotopes, chemical, mineralogical and bacteriological data).
Optical, near, infrared and ultraviolet monitoring of the Seyfert 1 galaxy Markarian 335
NASA Technical Reports Server (NTRS)
Shrader, Chris R.; Sun, W.-H.; Turner, T. J.; Hintzen, P. M.
1990-01-01
Preliminary results of a multifrequency monitoring campaign for the bright, Seyfert 1 galactic nuclei Mkn335 are presented. Nearly uniform sampling at 3 day intervals is achieved quasi simultaneously at each wavelength band. Wavelength dependent variability is seen at the 20 to 30 percent level. Interpretation of variability in terms of geometrically thin, optically thick accretion disk models is discussed. The inferred blackhole masses and accretion rates are discussed. Possible correlation between continuum and emission line variations is discussed.
Field trials of line transect methods applied to estimation of desert tortoise abundance
Anderson, David R.; Burnham, Kenneth P.; Lubow, Bruce C.; Thomas, L. E. N.; Corn, Paul Stephen; Medica, Philip A.; Marlow, R.W.
2001-01-01
We examine the degree to which field observers can meet the assumptions underlying line transect sampling to monitor populations of desert tortoises (Gopherus agassizii). We present the results of 2 field trials using artificial tortoise models in 3 size classes. The trials were conducted on 2 occasions on an area south of Las Vegas, Nevada, where the density of the test population was known. In the first trials, conducted largely by experienced biologists who had been involved in tortoise surveys for many years, the density of adult tortoise models was well estimated (-3.9% bias), while the bias was higher (-20%) for subadult tortoise models. The bias for combined data was -12.0%. The bias was largely attributed to the failure to detect all tortoise models on or near the transect centerline. The second trials were conducted with a group of largely inexperienced student volunteers and used somewhat different searching methods, and the results were similar to the first trials. Estimated combined density of subadult and adult tortoise models had a negative bias (-7.3%), again attributable to failure to detect some models on or near the centerline. Experience in desert tortoise biology, either comparing the first and second trials or in the second trial with 2 experienced biologists versus 16 novices, did not have an apparent effect on the quality of the data or the accuracy of the estimates. Observer training, specific to line transect sampling, and field testing are important components of a reliable survey. Line transect sampling represents a viable method for large-scale monitoring of populations of desert tortoise; however, field protocol must be improved to assure the key assumptions are met.
Wang, Lu; Liu, Tao; Chen, Yang; Sun, Yaqin; Xiu, Zhilong
2017-01-25
Biomass is an important parameter reflecting the fermentation dynamics. Real-time monitoring of biomass can be used to control and optimize a fermentation process. To overcome the deficiencies of measurement delay and manual errors from offline measurement, we designed an experimental platform for online monitoring the biomass during a 1,3-propanediol fermentation process, based on using the fourier-transformed near-infrared (FT-NIR) spectra analysis. By pre-processing the real-time sampled spectra and analyzing the sensitive spectra bands, a partial least-squares algorithm was proposed to establish a dynamic prediction model for the biomass change during a 1,3-propanediol fermentation process. The fermentation processes with substrate glycerol concentrations of 60 g/L and 40 g/L were used as the external validation experiments. The root mean square error of prediction (RMSEP) obtained by analyzing experimental data was 0.341 6 and 0.274 3, respectively. These results showed that the established model gave good prediction and could be effectively used for on-line monitoring the biomass during a 1,3-propanediol fermentation process.
21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...
21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...
21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...
21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass on-line blood gas monitor...
21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass on-line blood gas monitor...
Sensor, method and system of monitoring transmission lines
Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.
2012-10-02
An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.
Balest, Lydia; Murgolo, Sapia; Sciancalepore, Lucia; Montemurro, Patrizia; Abis, Pier Paolo; Pastore, Carlo; Mascolo, Giuseppe
2016-06-01
An on-line solid phase extraction coupled with high-performance liquid chromatography in tandem with mass spectrometry (on-line SPE/HPLC/MS-MS) method for the determination of five microcystins and nodularin in surface waters at submicrogram per liter concentrations has been optimized. Maximum recoveries were achieved by carefully optimizing the extraction sample volume, loading solvent, wash solvent, and pH of the sample. The developed method was also validated according to both UNI EN ISO IEC 17025 and UNICHIM guidelines. Specifically, ten analytical runs were performed at three different concentration levels using a reference mix solution containing the six analytes. The method was applied for monitoring the concentrations of microcystins and nodularin in real surface water during a sampling campaign of 9 months in which the ELISA method was used as standard official method. The results of the two methods were compared showing good agreement when the highest concentration values of MCs were found. Graphical abstract An on-line SPE/HPLC/MS-MS method for the determination of five microcystins and nodularin in surface waters at sub μg L(-1) was optimized and compared with ELISA assay method for real samples.
[Open-path online monitoring of ambient atmospheric CO2 based on laser absorption spectrum].
He, Ying; Zhang, Yu-Jun; Kan, Rui-Feng; Xia, Hui; Geng, Hui; Ruan, Jun; Wang, Min; Cui, Xiao-Juan; Liu, Wen-Qing
2009-01-01
With the conjunction of tunable diode laser absorption spectroscopy technology (TDLAS) and the open long optical path technology, the system designing scheme of CO2 on-line monitoring based on near infrared tunable diode laser absorption spectroscopy technology was discussed in detail, and the instrument for large-range measurement was set up. By choosing the infrared absorption line of CO2 at 1.57 microm whose line strength is strong and suitable for measurement, the ambient atmospheric CO2 was measured continuously with a 30 s temporal resolution at an suburb site in the autumn of 2007. The diurnal atmospheric variations of CO2 and continuous monitoring results were presented. The results show that the variation in CO2 concentration has an obvious diurnal periodicity in suburb where the air is free of interference and contamination. The general characteristic of diurnal variation is that the concentration is low in the daytime and high at night, so it matches the photosynthesis trend. The instrument can detect gas concentration online with high resolution, high sensitivity, high precision, short response time and many other advantages, the monitoring requires no gas sampling, the calibration is easy, and the detection limit is about 4.2 x 10(-7). It has been proved that the system and measurement project are feasible, so it is an effective method for gas flux continuous online monitoring of large range in ecosystem based on TDLAS technology.
Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis
Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej
2016-01-01
Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297
Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis.
Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej
2016-12-16
Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world.
Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis
NASA Technical Reports Server (NTRS)
Sutton, D. G.; Galvan, L.; Melzer, J.; Heidner, R. F., III
1979-01-01
The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.
In-line quality control of moving objects by means of spectral-domain OCT
NASA Astrophysics Data System (ADS)
Markl, Daniel; Hannesschläger, Günther; Buchsbaum, Andreas; Sacher, Stephan; Khinast, Johannes G.; Leitner, Michael
2014-08-01
In-line quality control of intermediate and final products is essential in various industries. This may imply determining the thickness of a foil or evaluating the homogeneity of coating applied to a pharmaceutical tablet. Such a qualitative and quantitative monitoring in a depth-resolved manner can be accomplished using optical coherence tomography (OCT). In-line quality control based on OCT requires additional consideration of motion effects for the system design as well as for data interpretation. This study focuses on transverse motion effects that can arise in spectral-domain (SD-) OCT systems. The impact of a transverse movement is analyzed for a constant relative speed difference up to 0.7 m/s between sample and sensor head. In particular, transverse motion is affecting OCT system properties such as the beam displacement (distance between adjacent A-scans) and transverse resolution. These properties were evaluated theoretically and experimentally for OCT images of a resolution target and pharmaceutical film-coated tablets. Both theoretical and experimental analyses highlight the shift of the transverse resolution limiting factor from the optics to the beam displacement above a relative speed difference between sensor head and sample of 0.42 m/s (for the presented SD-OCT setup). Speeds above 0.4 m/s are often demanded when monitoring industrial processes, such as a coating process when producing film-coated tablets. This emphasizes the importance of a fast data acquisition when using OCT as in-line quality control tool.
Sampling design for long-term regional trends in marine rocky intertidal communities
Irvine, Gail V.; Shelley, Alice
2013-01-01
Probability-based designs reduce bias and allow inference of results to the pool of sites from which they were chosen. We developed and tested probability-based designs for monitoring marine rocky intertidal assemblages at Glacier Bay National Park and Preserve (GLBA), Alaska. A multilevel design was used that varied in scale and inference. The levels included aerial surveys, extensive sampling of 25 sites, and more intensive sampling of 6 sites. Aerial surveys of a subset of intertidal habitat indicated that the original target habitat of bedrock-dominated sites with slope ≤30° was rare. This unexpected finding illustrated one value of probability-based surveys and led to a shift in the target habitat type to include steeper, more mixed rocky habitat. Subsequently, we evaluated the statistical power of different sampling methods and sampling strategies to detect changes in the abundances of the predominant sessile intertidal taxa: barnacles Balanomorpha, the mussel Mytilus trossulus, and the rockweed Fucus distichus subsp. evanescens. There was greatest power to detect trends in Mytilus and lesser power for barnacles and Fucus. Because of its greater power, the extensive, coarse-grained sampling scheme was adopted in subsequent years over the intensive, fine-grained scheme. The sampling attributes that had the largest effects on power included sampling of “vertical” line transects (vs. horizontal line transects or quadrats) and increasing the number of sites. We also evaluated the power of several management-set parameters. Given equal sampling effort, sampling more sites fewer times had greater power. The information gained through intertidal monitoring is likely to be useful in assessing changes due to climate, including ocean acidification; invasive species; trampling effects; and oil spills.
Probing the Physics of Active Galactic Nuclei
NASA Technical Reports Server (NTRS)
Peterson, Bradley M.
2004-01-01
As a result of a number of large multiwavelength monitoring campaigns that have taken place since the late 1980s, there are now several very large data sets on bright variable active galactic nuclei (AGNs) that are well-sampled in time and can be used to probe the physics of the AGN continuum source and the broad-line emitting region. Most of these data sets have been underutilized, as the emphasis thus far has been primarily on reverberation-mapping issues alone. Broader attempts at analysis have been made on some of the earlier IUE data sets (e.g., data from the 1989 campaign on NGC5 548) , but much of this analysis needs to be revisited now that improved versions of the data are now available from final archive processing. We propose to use the multiwavelength monitoring data that have been accumulated to undertake more thorough investigations of the AGN continuum and broad emission lines, including a more detailed study of line-profile variability, making use of constraints imposed by the reverberation results.
Tryland, Ingun; Eregno, Fasil Ejigu; Braathen, Henrik; Khalaf, Goran; Sjølander, Ingrid; Fossum, Marie
2015-01-01
The fully automated Colifast ALARMTM has been used for two years for daily monitoring of the presence/absence of Escherichia coli in 100 mL raw water at Oset drinking water treatment plant in Oslo, Norway. The raw water is extracted from 35 m depth from the Lake Maridalsvannet. E. coli was detected in 18% of the daily samples. In general, most samples positive for E. coli were observed during the autumn turnover periods, but even in some samples taken during warm and dry days in July, with stable temperature stratification in the lake, E. coli was detected. The daily samples gave useful additional information compared with the weekly routine samples about the hygienic raw water quality and the hygienic barrier efficiency of the lake under different weather conditions and seasons. The winter 2013/2014 was much warmer than the winter 2012/2013. The monitoring supported the hypothesis that warmer winters with shorter periods with ice cover on lakes, which may be a consequence of climate changes, may reduce the hygienic barrier efficiency in deep lakes used as drinking water sources. PMID:25658685
Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water
NASA Astrophysics Data System (ADS)
Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin
2018-02-01
With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.
Lens-free imaging-based low-cost microsensor for in-line wear debris detection in lube oils
NASA Astrophysics Data System (ADS)
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-02-01
The current paper describes the application of lens-free imaging principles for the detection and classification of wear debris in lubricant oils. The potential benefits brought by the lens-free microscopy techniques in terms of resolution, deep of field and active areas have been tailored to develop a micro sensor for the in-line monitoring of wear debris in oils used in lubricated or hydraulic machines as gearboxes, actuators, engines, etc. The current work presents a laboratory test-bench used for evaluating the optical performance of the lens-free approach applied to the wear particle detection in oil samples. Additionally, the current prototype sensor is presented, which integrates a LED light source, CMOS imager, embedded CPU, the measurement cell and the appropriate optical components for setting up the lens-free system. The imaging performance is quantified using micro structured samples, as well as by imaging real used lubricant oils. Probing a large volume with a decent 2D spatial resolution, this lens-free micro sensor can provide a powerful tool at very low cost for inline wear debris monitoring.
21 CFR 870.2620 - Line isolation monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Line isolation monitor. 870.2620 Section 870.2620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2620 Line isolation monitor...
21 CFR 870.2620 - Line isolation monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Line isolation monitor. 870.2620 Section 870.2620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2620 Line isolation monitor...
Zhang, Huijuan; Zhu, Jiping; Aranda-Rodriguez, Rocio; Feng, Yong-Lai
2011-11-07
Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)-electrospray ionization-tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013-0.12 μg L(-1) for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Filter for on-line air monitor unaffected by radon progeny and method of using same
Phillips, Terrance D.; Edwards, Howard D.
1999-01-01
An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.
Anderson, Kyle E.; Glenn, Nancy; Spaete, Lucas; Shinneman, Douglas; Pilliod, David S.; Arkle, Robert; McIlroy, Susan; Derryberry, DeWayne R.
2017-01-01
Terrestrial laser scanning (TLS) provides fast collection of high-definition structural information, making it a valuable field instrument to many monitoring applications. A weakness of TLS collections, especially in vegetation, is the occurrence of unsampled regions in point clouds where the sensor’s line-of-sight is blocked by intervening material. This problem, referred to as occlusion, may be mitigated by scanning target areas from several positions, increasing the chance that any given area will fall within the scanner’s line-of-sight from at least one position. Because TLS collections are often employed in remote regions where the scope of sampling is limited by logistical factors such as time and battery power, it is important to design field protocols which maximize efficiency and support increased quantity and quality of the data collected. This study informs researchers and practitioners seeking to optimize TLS sampling methods for vegetation monitoring in dryland ecosystems through three analyses. First, we quantify the 2D extent of occluded regions based on the range from single scan positions. Second, we measure the efficacy of additional scan positions on the reduction of 2D occluded regions (area) using progressive configurations of scan positions in 1 ha plots. Third, we test the reproducibility of 3D sampling yielded by a 5-scan/ha sampling methodology using redundant sets of scans. Analyses were performed using measurements at analysis scales of 5 to 50 cm across the 1-ha plots, and we considered plots in grass and shrub-dominated communities separately. In grass-dominated plots, a center-scan configuration and 5 cm pixel size sampled at least 90% of the area up to 18 m away from the scanner. In shrub-dominated plots, sampling at least 90% of the area was only achieved within a distance of 12 m. We found that 3 and 5 scans/ha are needed to sample at least ~ 70% of the total area (1 ha) in the grass and shrub-dominated plots, respectively, using 5 cm pixels to measure sampling presence-absence. The reproducibility of 3D sampling provided by a 5 position scan layout across 1-ha plots was 50% (shrub) and 70% (grass) using a 5-cm voxel size, whereas at the 50-cm voxel scale, reproducibility of sampling was nearly 100% for all plot types. Future studies applying TLS in similar dryland environments for vegetation monitoring may use our results as a guide to efficiently achieve sampling coverage and reproducibility in datasets.
Anderson, Kyle E; Glenn, Nancy F; Spaete, Lucas P; Shinneman, Douglas J; Pilliod, David S; Arkle, Robert S; McIlroy, Susan K; Derryberry, DeWayne R
2017-10-23
Terrestrial laser scanning (TLS) provides fast collection of high-definition structural information, making it a valuable field instrument to many monitoring applications. A weakness of TLS collections, especially in vegetation, is the occurrence of unsampled regions in point clouds where the sensor's line-of-sight is blocked by intervening material. This problem, referred to as occlusion, may be mitigated by scanning target areas from several positions, increasing the chance that any given area will fall within the scanner's line-of-sight from at least one position. Because TLS collections are often employed in remote regions where the scope of sampling is limited by logistical factors such as time and battery power, it is important to design field protocols which maximize efficiency and support increased quantity and quality of the data collected. This study informs researchers and practitioners seeking to optimize TLS sampling methods for vegetation monitoring in dryland ecosystems through three analyses. First, we quantify the 2D extent of occluded regions based on the range from single scan positions. Second, we measure the efficacy of additional scan positions on the reduction of 2D occluded regions (area) using progressive configurations of scan positions in 1 ha plots. Third, we test the reproducibility of 3D sampling yielded by a 5-scan/ha sampling methodology using redundant sets of scans. Analyses were performed using measurements at analysis scales of 5 to 50 cm across the 1-ha plots, and we considered plots in grass and shrub-dominated communities separately. In grass-dominated plots, a center-scan configuration and 5 cm pixel size sampled at least 90% of the area up to 18 m away from the scanner. In shrub-dominated plots, sampling at least 90% of the area was only achieved within a distance of 12 m. We found that 3 and 5 scans/ha are needed to sample at least ~ 70% of the total area (1 ha) in the grass and shrub-dominated plots, respectively, using 5 cm pixels to measure sampling presence-absence. The reproducibility of 3D sampling provided by a 5 position scan layout across 1-ha plots was 50% (shrub) and 70% (grass) using a 5-cm voxel size, whereas at the 50-cm voxel scale, reproducibility of sampling was nearly 100% for all plot types. Future studies applying TLS in similar dryland environments for vegetation monitoring may use our results as a guide to efficiently achieve sampling coverage and reproducibility in datasets.
Poiger, Thomas; Buerge, Ignaz J; Bächli, Astrid; Müller, Markus D; Balmer, Marianne E
2017-01-01
Glyphosate is currently one of the most important herbicides worldwide. Its unique properties provide for a wide range of uses in agriculture but also in non-agricultural areas. At the same time, its zwitterionic nature prevents the inclusion in multi-residue analytical methods for environmental monitoring. Consequently, despite its extensive use, data on occurrence of glyphosate in the aquatic environment is still scarce. Based on existing methods, we developed a simplified procedure for the determination of glyphosate and its main metabolite aminomethylphosphonic acid (AMPA) in water samples using derivatization with fluorenylmethyl chloroformate FMOC-Cl, combined with on-line solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) detection. This method was extensively tested on over 1000 samples of surface water, groundwater, and treated wastewater and proved to be simple, sensitive, and reliable. Limits of quantification of 0.005 μg/L were routinely achieved. Glyphosate and AMPA were detected in the vast majority of stream water samples in the area of Zurich, Switzerland, with median concentrations of 0.11 and 0.20 μg/L and 95th percentile concentrations of 2.1 and 2.6 μg/L, respectively. Stream water data and data from treated wastewater indicated that non-agricultural uses may significantly contribute to the overall loads of glyphosate and AMPA in surface waters. In the investigated groundwater samples, selected specifically because they had shown presence of other herbicides in previous monitoring programs, glyphosate and AMPA were generally not detected, except for two monitoring sites in Karst aquifers, indicating that these compounds show much less tendency for leaching.
Filtration of water-sediment samples for the determination of organic compounds
Sandstrom, Mark W.
1995-01-01
This report describes the equipment and procedures used for on-site filtration of surface-water and ground-water samples for determination of organic compounds. Glass-fiber filters and a positive displacement pumping system are suitable for processing most samples for organic analyses. An optional system that uses disposable in-line membrane filters is suitable for a specific gas chromatography/mass spectrometry, selected-ion monitoring analytical method for determination of organonitrogen herbicides. General procedures to minimize contamination of the samples include preparing a clean workspace at the site, selecting appropriate sample-collection materials, and cleaning of the equipment with detergent, tap water, and methanol.
NASA Astrophysics Data System (ADS)
Tseng, Tung-Tse
In this research the interferences with the on -line detection of radioiodines, under nuclear accident conditions, were studied. The special tool employed for this research is the developed on-line radioiodine monitor (the Penn State Radioiodine Monitor), which is capable of detecting low levels of radioiodine on-line in air containing orders of magnitude higher levels of radioactive noble gases. Most of the data reported in this thesis were collected during a series of experiments called "Source -Term Experiment Program (STEP)." The experiments were conducted at the Argonne National Laboratory's TREAT reactor located at the Idaho National Engineering Laboratory (INEL). In these tests, fission products were released from the Light Water Reactor (LWR) test fuels as a result of simulating a reactor accident. The Penn State Monitor was then used to sample the fission products accumulated in a large container which simulated the reactor containment building. The test results proved that the Penn State Monitor was not affected significantly by the passage of large amounts of noble gases through the system. Also, it confirmed the predicted results that the operation of conventional on-line radioiodine detectors would, under nuclear accident conditions, be seriously impaired by the passage of high concentrations of radioactive noble gases through such systems. This work also demonstrated that under conditions of high noble gas concentrations and low radioiodine concentrations, the formation of noble-gas-decayed alkali metals can seriously interfere with the on-line detection of radioiodine, especially during the 24 hours immediately after the accident. The decayed alkali metal particulates were also found to be much more penetrating than the ordinary type of particulates, since a large fraction (15%) of the particulates were found to penetrate through the commonly used High Efficiency Particulate Air (HEPA) filter (rated >99.97% for 0.3 (mu)m particulate). Also, a significant fraction ((TURN)40%) of these particles became deposited on silver zeolite iodine filters inside the counting chamber. Finally, the Penn State Monitor proved itself to be a powerful research tool for the on-line source term studies since it can easily produce near noble-gas-free spectra during the real time studies occurring under simulated nuclear accident conditions.
Zhang, J; Xie, Y; Dai, X; Wei, W
2001-03-01
A new method monitoring Lactobacillus fermentation process, which combines ion chromatography (IC) with a series piezoelectric quartz crystal (SPQC) technique, is presented in this paper. Monitoring of the fermentation process was realized by examining the rate of production of lactic acid. An automatic membrane dialyser was used for the pretreatment of the sample in on-line monitoring. A mixture of p-hydroxybenzoic acid and N,N-diethylethanolamine was adopted as mobile phase and its flow rate was 0.8 ml/min. The effects of some fermentation conditions were also discussed in detail. Accordingly, the optimal fermentation conditions were obtained. This method is simple and convenient while the results obtained are accurate and reliable.
APDS: the autonomous pathogen detection system.
Hindson, Benjamin J; Makarewicz, Anthony J; Setlur, Ujwal S; Henderer, Bruce D; McBride, Mary T; Dzenitis, John M
2005-04-15
We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic acid-based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for 7 days in a major U.S. transportation hub is reported.
Alinoori, Amir Hossein; Masoum, Saeed
2018-05-22
A unique metal oxide semiconductor sensor (MOS) array detector with eight sensors was designed and fabricated in a PTFE chamber as an interface for coupling with multicapillary gas chromatography. This design consists of eight transfer lines with equal length between the multicapillary columns (MCC) and sensors. The deactivated capillary columns were passed through each transfer line and homemade flow splitter to distribute the same gas flow on each sensor. Using the eight ports flow splitter design helps us to equal the length of carrier gas path and flow for each sensor, minimizing the dead volume of the sensor's chamber and increasing chromatographic resolution. In addition to coupling of MCC to MOS array detector and other considerations in hardware design, modulation of MOS temperature was used to increase sensitivity and selectivity, and data analysis was enhanced with adapted Gaussian apodization factor analysis (GAFA) as a multivariate curve resolution algorithm. Continues air sampling and injecting system (CASI) design provides a fast and easily applied method for continues injection of air sample with no additional sample preparation. The analysis cycle time required for each run is less than 300 s. The high sample load and sharp injection with the fast separation by MCC decrease the peak widths and improve detection limits. This homemade customized instrument is an alternative to other time-consuming and expensive technologies for continuous monitoring of outgassing in air samples.
Presley, Todd K.; Jamison, Marcael T.J.
2009-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream, and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at five stations, and water-quality data at six stations, which include the five continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2008, and June 30, 2009. Within the Halawa Stream drainage area, three storms (October 25 and December 11, 2008, and February 3, 2009) were sampled during July 1, 2008, to June 30, 2009. A total of 43 environmental samples were collected during these three storms. During the storm of October 25, 2009, 31 samples were collected and analyzed individually for metals only. The other 12 samples from the other two storms were analyzed for some or all of the following analytes: total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for some or all of the following analytes: oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some grab and composite samples were analyzed for only a partial list of these analytes, either because samples could not be delivered to the laboratory in a timely manner, or an insufficient volume of sample was collected by the automatic samplers. Two quality-assurance/quality-control samples were collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. Four environmental samples were collected at the H-1 Storm Drain during July 1, 2008, to June 30, 2009. An oil and grease sample and a composite sample were collected during the storm on November 15, 2008, and two composite samples were collected during the January 11, 2009, storm. All samples at this site were collected using an automatic sampler. Samples were analyzed for some or all of the following analytes: total suspended solids, nutrients, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). One qualityassurance/quality-control sample was collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. During the storm of January 11, 2009, the two composite samples collected at H-1 Storm Drain were collected about three hours apart. Higher constituent concentrations were detected in the first 2 composite sample relative to the second composite sample, although the average discharge was higher during the period when the second sample was collected.
AI mass spectrometers for space shuttle health monitoring
NASA Technical Reports Server (NTRS)
Adams, F. W.
1991-01-01
The facility Hazardous Gas Detection System (HGDS) at Kennedy Space Center (KSC) is a mass spectrometer based gas analyzer. Two instruments make up the HGDS, which is installed in a prime/backup arrangement, with the option of using both analyzers on the same sample line, or on two different lines simultaneously. It is used for monitoring the Shuttle during fuel loading, countdown, and drainback, if necessary. The use of complex instruments, operated over many shifts, has caused problems in tracking the status of the ground support equipment (GSE) and the vehicle. A requirement for overall system reliability has been a major force in the development of Shuttle GSE, and is the ultimate driver in the choice to pursue artificial intelligence (AI) techniques for Shuttle and Advanced Launch System (ALS) mass spectrometer systems. Shuttle applications of AI are detailed.
NASA Technical Reports Server (NTRS)
Madsen, B. C.
1980-01-01
The results of a study which was designed to monitor, characterize, and evaluate the chemical composition of precipitation (rain) which fell at the Kennedy Space Center, Florida (KSC) during the period July 1977 to March 1979 are reported. Results which were obtained from a soil sampling and associated chemical analysis are discussed. The purpose of these studies was to determine the environmental perturbations which might be caused by NASA space activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentz, Misty C.; Walsh, Jonelle L.; Barth, Aaron J.
2009-11-01
We have recently completed a 64-night spectroscopic monitoring campaign at the Lick Observatory 3-m Shane telescope with the aim of measuring the masses of the black holes in 12 nearby (z < 0.05) Seyfert 1 galaxies with expected masses in the range approx10{sup 6}-10{sup 7} M {sub sun} and also the well-studied nearby active galactic nucleus (AGN) NGC 5548. Nine of the objects in the sample (including NGC 5548) showed optical variability of sufficient strength during the monitoring campaign to allow for a time lag to be measured between the continuum fluctuations and the response to these fluctuations in themore » broad Hbeta emission. We present here the light curves for all the objects in this sample and the subsequent Hbeta time lags for the nine objects where these measurements were possible. The Hbeta lag time is directly related to the size of the broad-line region (BLR) in AGNs, and by combining the Hbeta lag time with the measured width of the Hbeta emission line in the variable part of the spectrum, we determine the virial mass of the central supermassive black hole in these nine AGNs. The absolute calibration of the black hole masses is based on the normalization derived by Onken et al., which brings the masses determined by reverberation mapping into agreement with the local M {sub BH}-sigma{sub *}relationship for quiescent galaxies. We also examine the time lag response as a function of velocity across the Hbeta line profile for six of the AGNs. The analysis of four leads to rather ambiguous results with relatively flat time lags as a function of velocity. However, SBS 1116+583A exhibits a symmetric time lag response around the line center reminiscent of simple models for circularly orbiting BLR clouds, and Arp 151 shows an asymmetric profile that is most easily explained by a simple gravitational infall model. Further investigation will be necessary to fully understand the constraints placed on the physical models of the BLR by the velocity-resolved response in these objects.« less
Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.
Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S
2012-06-27
Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.
Chung, Y T; Ling, Y C; Yang, C S; Sun, Y C; Lee, P L; Lin, C Y; Hong, C C; Yang, M H
2007-12-01
We have developed an on-line analytical system involving microdialysis (MD) sampling, a carbohydrate membrane desalter (CMD), and an inductively coupled plasma mass spectrometer (ICPMS) system for the simultaneous determination of multiple trace metals in the extracellular fluid (ECF) in the brains of anesthetized rats. The microdialysate that perfused from the animal at a flow rate of 0.5 microL/min was on-line transferred to the CMD to remove the high-sodium matrix, followed by ICPMS measurement. The role of the CMD in this on-line system was investigated in detail. With prior addition of EDTA to the microdialysate to form anionic complexes of the metal analytes and the use of NH4Cl as a regenerant to exchange Na(+) with NH4(+) ions, both quantitative recovery of the trace metal analytes and quantitative removal of the sodium matrix could be achieved. Two experimental modes of the monitoring system were constructed. For those metals (e.g., Cu, Zn, and Mn) that existed at (sub)nanogram-per-milliliter concentrations in the microdialysate, the temporal resolution was 10 min when using a 10 microL loop for sample collection, followed by CMD and ICPMS; for those elements (e.g., Ca and Mg) that existed at microgram-per-milliliter levels (or greater), near-real-time analysis was possible because the microdialysate could be led, bypassing the sample loop, directly to the CMD for desalting without any time delay. Further improvement of the temporal resolution for the low-concentration elements was not possible without decreasing the detection limits of mass detection. Among the eight trace metals tested using this on-line system, the method detection limits for Cu, Zn, Mn, Co, Ni, and Pb reached subnanogram-per-milliliter levels; for electrolyte species such as Ca and Mg, the detection limits were in the range of 50-100 ng/mL. Analytical accuracy, expressed as spike recovery, was 100% +/- 15% for all of the elements tested. We demonstrate the applicability of the proposed system through the successful measurement of the basal values of Ca, Mg, Cu, Zn, and Mn in the ECF of a living rat brain and through in vivo monitoring of the concentration profiles of Mn and Pt in the ECF after the injection of drugs (MnCl2 and cisplatin) into the rats. This microdialysis system is the first to offer real-time, in vivo monitoring of trace elements such as Ca and Mg.
NASA Astrophysics Data System (ADS)
E. Romero, Carlos; De Saro, Robert
Coal is a non-uniform material with large inherent variability in composition, and other important properties, such as calorific value and ash fusion temperature. This quality variability is very important when coal is used as fuel in steam generators, since it affects boiler operation and control, maintenance and availability, and the extent and treatment of environmental pollution associated with coal combustion. On-line/in situ monitoring of coal before is fed into a boiler is a necessity. A very few analytical techniques like X-ray fluorescence and prompt gamma neutron activation analysis are available commercially with enough speed and sophistication of data collection for continuous coal monitoring. However, there is still a need for a better on-line/in situ technique that has higher selectivity, sensitivity, accuracy and precision, and that is safer and has a lower installation and operating costs than the other options. Laser induced breakdown spectroscopy (LIBS) is ideal for coal monitoring in boiler applications as it need no sample preparation, it is accurate and precise it is fast, and it can detect all of the elements of concern to the coal-fired boiler industry. LIBS data can also be adapted with advanced data processing techniques to provide real-time information required by boiler operators nowadays. This chapter summarizes development of LIBS for on-line/in situ coal applications in utility boilers.
Ho, Jeff C; Russel, Kory C; Davis, Jennifer
2014-03-01
Support is growing for the incorporation of fetching time and/or distance considerations in the definition of access to improved water supply used for global monitoring. Current efforts typically rely on self-reported distance and/or travel time data that have been shown to be unreliable. To date, however, there has been no head-to-head comparison of such indicators with other possible distance/time metrics. This study provides such a comparison. We examine the association between both straight-line distance and self-reported one-way travel time with measured route distances to water sources for 1,103 households in Nampula province, Mozambique. We find straight-line, or Euclidean, distance to be a good proxy for route distance (R(2) = 0.98), while self-reported travel time is a poor proxy (R(2) = 0.12). We also apply a variety of time- and distance-based indicators proposed in the literature to our sample data, finding that the share of households classified as having versus lacking access would differ by more than 70 percentage points depending on the particular indicator employed. This work highlights the importance of the ongoing debate regarding valid, reliable, and feasible strategies for monitoring progress in the provision of improved water supply services.
Young People's Cognitive Achievement as Fostered by Hands-on-Centred Environmental Education
ERIC Educational Resources Information Center
Dieser, Olivia; Bogner, Franz X.
2016-01-01
In line with previous studies, where outdoor nature experience was shown to support adolescents' environmental knowledge, our study monitored the influence of a hands-on environmental programme within a National Park on cognitive knowledge achievement. A sample of 4th and 5th graders (n = 289) completed a week-long outreach conservation programme…
Sparacino, Giovanni; Zanon, Mattia; Facchinetti, Andrea; Zecchin, Chiara; Maran, Alberto; Cobelli, Claudio
2012-01-01
Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community. PMID:23202020
Sparacino, Giovanni; Zanon, Mattia; Facchinetti, Andrea; Zecchin, Chiara; Maran, Alberto; Cobelli, Claudio
2012-10-12
Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.
Zaninelli, Mauro; Tangorra, Francesco Maria; Costa, Annamaria; Rossi, Luciana; Dell'Orto, Vittorio; Savoini, Giovanni
2016-07-13
The aim of this study was to develop and test a new fuzzy logic model for monitoring the udder health status (HS) of goats. The model evaluated, as input variables, the milk electrical conductivity (EC) signal, acquired on-line for each gland by a dedicated sensor, the bandwidth length and the frequency and amplitude of the first main peak of the Fourier frequency spectrum of the recorded milk EC signal. Two foremilk gland samples were collected from eight Saanen goats for six months at morning milking (lactation stages (LS): 0-60 Days In Milking (DIM); 61-120 DIM; 121-180 DIM), for a total of 5592 samples. Bacteriological analyses and somatic cell counts (SCC) were used to define the HS of the glands. With negative bacteriological analyses and SCC < 1,000,000 cells/mL, glands were classified as healthy. When bacteriological analyses were positive or showed a SCC > 1,000,000 cells/mL, glands were classified as not healthy (NH). For each EC signal, an estimated EC value was calculated and a relative deviation was obtained. Furthermore, the Fourier frequency spectrum was evaluated and bandwidth length, frequency and amplitude of the first main peak were identified. Before using these indexes as input variables of the fuzzy logic model a linear mixed-effects model was developed to evaluate the acquired data considering the HS, LS and LS × HS as explanatory variables. Results showed that performance of a fuzzy logic model, in the monitoring of mammary gland HS, could be improved by the use of EC indexes derived from the Fourier frequency spectra of gland milk EC signals recorded by on-line EC sensors.
Zhu, Xiaocui; Xu, Lei; Wu, Tongbo; Xu, Anqin; Zhao, Meiping; Liu, Shaorong
2014-05-15
We demonstrate a novel fluorescent sensor for real-time and continuous monitoring of the variation of bisulfide in microdialysis effluents by using a nanoparticle-glutathione-fluorescein isothiocyanate (AuNP-GSH-FITC) probe coupled with on-line droplet-based microfluidic chip. The AuNP-GSH-FITC fluorescent probe was firstly developed and used for bisulfide detection in bulk solution by quantitative real-time PCR, which achieved a linear working range from 0.1 μM to 5.0 μM and a limit of detection of ~50 nM. The response time was less than 2 min. With the aid of co-immobilized thiol-polyethylene glycol, the probe exhibited excellent stability and reproducibility in high salinity solutions, including artificial cerebrospinal fluids (aCSF). By adding 0.1% glyoxal to the probe solution, the assay allowed quantification of bisulfide in the presence of cysteine at the micro-molarity level. Using the AuNP-GSH-FITC probe, a droplet-based microfluidic fluorescent sensor was further constructed for online monitoring of bisulfide variation in the effluent of microdialysis. By using fluorescence microscope-charge-coupled device camera as the detector, the integrated microdialysis/microfluidic chip device achieved a detection limit of 2.0 μM and a linear response from 5.0 μM to 50 μM for bisulfide in the tested sample. The method was successfully applied for the on-line measurement of bisulfide variation in aCSF and serum samples. It will be a very useful tool for tracking the variation of bisulfide or hydrogen sulfide in extracellular fluids. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gärtner, Claudia; Becker, Holger; Hlawatsch, Nadine; Klemm, Richard; Moche, Christian; Schattschneider, Sebastian; Frank, Rainer; Willems, Andreas
2015-05-01
The diverse human HLA (human leukocyte antigen) system is responsible for antigen presentation and recognition. It is essential for the immune system to maintain a stable defense line, but also is also involved in autoimmunity as well as metabolic disease. HLA-haplotype (HLA-B27), for instance, is associated with inflammatory diseases such as Bechterew's disease. The administration of the HIV drug Abacavir in combination with another HLA-haplotype (HLAB57) is associated with severe hypersensitivity reactions. Accordingly, the HLA status has to be monitored for diagnosis or prior to start of therapy. Along this line, a miniaturized microfluidic platform has been developed allowing performing the complete analytical process from "sample-in" to "answer-out" in a point-of-care environment. The main steps of the analytical cascade inside the integrated system are blood cell lysis and DNA isolation, DNA purification, real-time PCR and quantitative monitoring of the rise of a fluorescent signal appearing during the PCR based sequence amplification. All bio-analytical steps were intended to be performed inside one chip and will be actuated, controlled and monitored by a matching device. This report will show that all required processes are established and tested and all device components work well and interact with the functional modules on the chips in a harmonized fashion.
Flow-injection assay of catalase activity.
Ukeda, Hiroyuki; Adachi, Yukiko; Sawamura, Masayoshi
2004-03-01
A novel flow-injection assay (FIA) system with a double line for catalase activity was constructed in which an oxidase is immobilized and the substrate is continuously pumped to reduce the dissolved oxygen and to generate a given level of hydrogen peroxide. The catalase in a sample decomposed the hydrogen peroxide, and thus the increase in dissolved oxygen dependent on the activity was amperometrically monitored using a Clark-type oxygen electrode. Among the examined several oxidases, uricase was most suitable for the continuous formation of hydrogen peroxide from a consideration of the stability and the conversion efficiency. Under the optimum conditions, a linear calibration curve was obtained in the range from 21 to 210 units/mg and the reproducibility (CV) was better than 2% by 35 successive determinations of 210 units/ml catalase preparation. The sampling frequency was about 15 samples/h. The present FIA system was applicable to monitor the inactivation of catalase by glycation.
Single transmission line interrogated multiple channel data acquisition system
Fasching, George E.; Keech, Jr., Thomas W.
1980-01-01
A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.
Sopori, Bhushan; Rupnowski, Przemyslaw; Ulsh, Michael
2016-01-12
A monitoring system 100 comprising a material transport system 104 providing for the transportation of a substantially planar material 102, 107 through the monitoring zone 103 of the monitoring system 100. The system 100 also includes a line camera 106 positioned to obtain multiple line images across a width of the material 102, 107 as it is transported through the monitoring zone 103. The system 100 further includes an illumination source 108 providing for the illumination of the material 102, 107 transported through the monitoring zone 103 such that light reflected in a direction normal to the substantially planar surface of the material 102, 107 is detected by the line camera 106. A data processing system 110 is also provided in digital communication with the line camera 106. The data processing system 110 is configured to receive data output from the line camera 106 and further configured to calculate and provide substantially contemporaneous information relating to a quality parameter of the material 102, 107. Also disclosed are methods of monitoring a quality parameter of a material.
Water quality monitor. [spacecraft potable water
NASA Technical Reports Server (NTRS)
West, S.; Crisos, J.; Baxter, W.
1979-01-01
The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.
Off-line real-time FTIR analysis of a process step in imipenem production
NASA Astrophysics Data System (ADS)
Boaz, Jhansi R.; Thomas, Scott M.; Meyerhoffer, Steven M.; Staskiewicz, Steven J.; Lynch, Joseph E.; Egan, Richard S.; Ellison, Dean K.
1992-08-01
We have developed an FT-IR method, using a Spectra-Tech Monit-IR 400 systems, to monitor off-line the completion of a reaction in real-time. The reaction is moisture-sensitive and analysis by more conventional methods (normal-phase HPLC) is difficult to reproduce. The FT-IR method is based on the shift of a diazo band when a conjugated beta-diketone is transformed into a silyl enol ether during the reaction. The reaction mixture is examined directly by IR and does not require sample workup. Data acquisition time is less than one minute. The method has been validated for specificity, precision and accuracy. The results obtained by the FT-IR method for known mixtures and in-process samples compare favorably with those from a normal-phase HPLC method.
Transmission Line Security Monitor
None
2017-12-09
The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.
Capozzi, Vittorio; Yener, Sine; Khomenko, Iuliia; Farneti, Brian; Cappellin, Luca; Gasperi, Flavia; Scampicchio, Matteo; Biasioli, Franco
2017-05-11
Proton Transfer Reaction (PTR), combined with a Time-of-Flight (ToF) Mass Spectrometer (MS) is an analytical approach based on chemical ionization that belongs to the Direct-Injection Mass Spectrometric (DIMS) technologies. These techniques allow the rapid determination of volatile organic compounds (VOCs), assuring high sensitivity and accuracy. In general, PTR-MS requires neither sample preparation nor sample destruction, allowing real time and non-invasive analysis of samples. PTR-MS are exploited in many fields, from environmental and atmospheric chemistry to medical and biological sciences. More recently, we developed a methodology based on coupling PTR-ToF-MS with an automated sampler and tailored data analysis tools, to increase the degree of automation and, consequently, to enhance the potential of the technique. This approach allowed us to monitor bioprocesses (e.g. enzymatic oxidation, alcoholic fermentation), to screen large sample sets (e.g. different origins, entire germoplasms) and to analyze several experimental modes (e.g. different concentrations of a given ingredient, different intensities of a specific technological parameter) in terms of VOC content. Here, we report the experimental protocols exemplifying different possible applications of our methodology: i.e. the detection of VOCs released during lactic acid fermentation of yogurt (on-line bioprocess monitoring), the monitoring of VOCs associated with different apple cultivars (large-scale screening), and the in vivo study of retronasal VOC release during coffee drinking (nosespace analysis).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentz, Misty C.; Walsh, Jonelle L.; Barth, Aaron J.
2010-06-20
We have recently completed a 64-night spectroscopic monitoring campaign at the Lick Observatory 3 m Shane telescope with the aim of measuring the masses of the black holes in 12 nearby (z < 0.05) Seyfert 1 galaxies with expected masses in the range {approx}10{sup 6}-10{sup 7} M{sub sun} and also the well-studied nearby active galactic nucleus (AGN) NGC 5548. Nine of the objects in the sample (including NGC 5548) showed optical variability of sufficient strength during the monitoring campaign to allow for a time lag to be measured between the continuum fluctuations and the response to these fluctuations in themore » broad H{beta} emission, which we have previously reported. We present here the light curves for the H{alpha}, H{gamma}, He II {lambda}4686, and He I {lambda}5876 emission lines and the time lags for the emission-line responses relative to changes in the continuum flux. Combining each emission-line time lag with the measured width of the line in the variable part of the spectrum, we determine a virial mass of the central supermassive black hole from several independent emission lines. We find that the masses are generally consistent within the uncertainties. The time-lag response as a function of velocity across the Balmer line profiles is examined for six of the AGNs. We find similar responses across all three Balmer lines for Arp 151, which shows a strongly asymmetric profile, and for SBS 1116+583A and NGC 6814, which show a symmetric response about zero velocity. For the other three AGNs, the data quality is somewhat lower and the velocity-resolved time-lag response is less clear. Finally, we compare several trends seen in the data set against the predictions from photoionization calculations as presented by Korista and Goad. We confirm several of their predictions, including an increase in responsivity and a decrease in the mean time lag as the excitation and ionization level for the species increases. Specifically, we find the time lags of the optical recombination lines to have weighted mean ratios of {tau}(H{alpha}):{tau}(H{beta}):{tau}(H{gamma}):{tau}(He I):{tau}(He II) = 1.54:1.00:0.61:0.36:0.25. Further confirmation of photoionization predictions for broad-line gas behavior will require additional monitoring programs for these AGNs while they are in different luminosity states.« less
Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori
2011-07-01
A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Long-term microfluidic glucose and lactate monitoring in hepatic cell culture
Prill, Sebastian; Jaeger, Magnus S.; Duschl, Claus
2014-01-01
Monitoring cellular bioenergetic pathways provides the basis for a detailed understanding of the physiological state of a cell culture. Therefore, it is widely used as a tool amongst others in the field of in vitro toxicology. The resulting metabolic information allows for performing in vitro toxicology assays for assessing drug-induced toxicity. In this study, we demonstrate the value of a microsystem for the fully automated detection of drug-induced changes in cellular viability by continuous monitoring of the metabolic activity over several days. To this end, glucose consumption and lactate secretion of a hepatic tumor cell line were continuously measured using microfluidically addressed electrochemical sensors. Adapting enzyme-based electrochemical flat-plate sensors, originally designed for human whole-blood samples, to their use with cell culture medium supersedes the common manual and laborious colorimetric assays and off-line operated external measurement systems. The cells were exposed to different concentrations of the mitochondrial inhibitor rotenone and the cellular response was analyzed by detecting changes in the rates of the glucose and lactate metabolism. Thus, the system provides real-time information on drug-induced liver injury in vitro. PMID:24926387
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J; Kertesz, Vilmos; Koeplinger, Kenneth A.
2008-01-01
A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse bodymore » tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.« less
Su, Cheng-Kuan; Hsia, Sheng-Chieh; Sun, Yuh-Chang
2014-08-01
We have developed a simple and low-cost flow injection system coupled to a quadruple ICP-MS for the direct and continuous determination of multi-element in microdialysates. To interface microdialysis sampling to an inductively coupled plasma mass spectrometer (ICP-MS), we employed 3D printing to manufacture an as-designed sample load/inject valve featuring an in-valve sample loop for precise handling of microliter samples with a dissolved solids content of 0.9% NaCl (w/v). To demonstrate the practicality of our developed on-line system, we applied the 3D printed valve equipped a 5-μL sample loop to minimize the occurrence of salt matrix effects and facilitate an online dynamic monitoring of extracellular calcium and zinc ions in living rat brains. Under the practical condition (temporal resolution: 10h(-1)), dynamic profiling of these two metal ions in living rat brain extracellular fluid after probe implantation (the basal values for Ca and Zn were 12.11±0.10mg L(-1) and 1.87±0.05μg L(-1), respectively) and real-time monitoring of the physiological response to excitotoxic stress elicited upon perfusing a solution of 2.5mM N-methyl-d-aspartate were performed. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Daneshmend, L. K.; Pak, H. A.
1984-02-01
On-line monitoring of the cutting process in CNC lathe is desirable to ensure unattended fault-free operation in an automated environment. The state of the cutting tool is one of the most important parameters which characterises the cutting process. Direct monitoring of the cutting tool or workpiece is not feasible during machining. However several variables related to the state of the tool can be measured on-line. A novel monitoring technique is presented which uses cutting torque as the variable for on-line monitoring. A classifier is designed on the basis of the empirical relationship between cutting torque and flank wear. The empirical model required by the on-line classifier is established during an automated training cycle using machine vision for off-line direct inspection of the tool.
Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.
1981-06-04
suction return connection port will require the operator to secuire same from a squatting position. The present stowage arrangement on the test stand... SPC FC sample~~~ Iepal" -a *Tpoa _______Rate 7 eo3,t Sq,’ TPc owe te - U Enciosure ULeeds & Northrup N’AFC- 92- 1 0 Typical Plumbing Connections for
NASA Astrophysics Data System (ADS)
Santoyo, E.; Verma, S. P.; Nieva, D.; Portugal, E.
1991-07-01
Studies related to hydrological structure of the Los Azufres geothermal field and its effects on the exploitation of the field for generation of electrical energy have included a program of sampling and chemical analysis of fluids discharged by a number of deep wells in continuous production. Chemical analysis of the gaseous phase includes monitoring of CO 2, H 2S, NH 3, H 2, He, N 2, CH 4 and 222Rn. Five wells in Los Azufres field were periodically sampled during 1983-1988. The monitoring program has shown considerable variability in the gas concentrations of fluids. Before mid-1985, the 'base-line' concentrations of the gases showed standard deviations between 8 and 28%. During the later period, the average concentrations of different gases ranged from 37% to much higher values above the 'base-line'. The largest variations are observed in He, CO 2 and 222Rn. This variability is interpreted in terms of (1) addition of 'excess steam', (2) a possible relationship with earthquake events that occurred in México during September 19-21, 1985, and early May to early June of 1987 and, (3) more recent variations (after mid-1987), increased exploitation of the field.
Dinon, Andréia Z; Bosco, Kenia T; Arisi, Ana Carolina M
2010-07-01
The first genetically modified (GM) maize lines were approved for trading in Brazil after December 2007 and they were T25, MON810, Bt11, NK603 and GA21. The polymerase chain reaction (PCR) method was employed to monitor the presence of Bt11 and nested PCR was used to detect the presence of Bt176 in 81 maize-derived products (maize flour, corn meal, maize flour flakes and polenta) that were sold in Brazilian market from 2005 to 2007, before the release of GM maize in Brazil. The PCR detection limit for Bt11 was 10 g kg(-1) and for nested PCR of Bt176 it was 1 g kg(-1). All Brazilian samples analyzed showed no positive signal for these GM maize events. Bt11 and Bt176 GM maize lines were not detected by specific PCR in 81 maize-derived food samples sold in Brazil from 2005 to 2007, before the commercial release of GM maize in Brazil. These Brazilian food industries were in compliance with the rules stipulated by the current legislation with respect to consumer requirements about GMO labeling.
Wireless Sensor Network for Electric Transmission Line Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alphenaar, Bruce
Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and costmore » effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).« less
Computerized EEG analysis for studying the effect of drugs on the central nervous system.
Rosadini, G; Cavazza, B; Rodriguez, G; Sannita, W G; Siccardi, A
1977-11-01
Samples of our experience in quantitative pharmaco-EEG are reviewed to discuss and define its applicability and limits. Simple processing systems, such as the computation of Hjorth's descriptors, are useful for on-line monitoring of drug-induced EEG modifications which are evident also at the visual visual analysis. Power spectral analysis is suitable to identify and quantify EEG effects not evident at the visual inspection. It demonstrated how the EEG effects of compounds in a long-acting formulation vary according to the sampling time and the explored cerebral area. EEG modifications not detected by power spectral analysis can be defined by comparing statistically (F test) the spectral values of the EEG from a single lead at the different samples (longitudinal comparison), or the spectral values from different leads at any sample (intrahemispheric comparison). The presently available procedures of quantitative pharmaco-EEG are effective when applied to the study of mutltilead EEG recordings in a statistically significant sample of population. They do not seem reliable in the monitoring of directing of neuropyschiatric therapies in single patients, due to individual variability of drug effects.
NASA Technical Reports Server (NTRS)
Wallace, Sarah
2017-01-01
Why do we need a DNA sequencer to support the human exploration of space? (A) Operational environmental monitoring; (1) Identification of contaminating microbes, (2) Infectious disease diagnosis, (3) Reduce down mass (sample return for environmental monitoring, crew health, etc.). (B) Research; (1) Human, (2) Animal, (3) Microbes/Cell lines, (4) Plant. (C) Med Ops; (1) Response to countermeasures, (2) Radiation, (3) Real-time analysis can influence medical intervention. (C) Support astrobiology science investigations; (1) Technology superiorly suited to in situ nucleic acid-based life detection, (2) Functional testing for integration into robotics for extraplanetary exploration mission.
The Gamma-Ray Emitting Radio-Loud Narrow-Line Seyfert 1 Galaxy PKS 2004-447 II. The Radio View
NASA Technical Reports Server (NTRS)
Schulz, R.; Kreikenbohm, A.; Kadler, M.; Ojha, R.; Ros, E.; Stevens, J.; Edwards, P. G.; Carpenter, B.; Elsaesser, D.; Gehrels, N.;
2016-01-01
Context. gamma-ray-detected radio-loud narrow-line Seyfert 1 (gamma-NLS1) galaxies constitute a small but interesting sample of the gamma-ray-loud AGN. The radio-loudest gamma-NLS1 known, PKS2004447, is located in the southern hemisphere and is monitored in the radio regime by the multiwavelength monitoring programme TANAMI. Aims. We aim for the first detailed study of the radio morphology and long-term radio spectral evolution of PKS2004447, which are essential for understanding the diversity of the radio properties of gamma-NLS1s. Methods. The TANAMI VLBI monitoring program uses the Australian Long Baseline Array (LBA) and telescopes in Antarctica, Chile, New Zealand, and South Africa to monitor the jets of radio-loud active galaxies in the southern hemisphere. Lower resolution radio flux density measurements at multiple radio frequencies over four years of observations were obtained with the Australia Telescope Compact Array (ATCA). Results. The TANAMI VLBI image at 8.4GHz shows an extended one-sided jet with a dominant compact VLBI core. Its brightness temperature is consistent with equipartition, but it is an order of magnitude below other gamma-NLS1s with the sample value varying over two orders of magnitude. We find a compact morphology with a projected large-scale size 11 kpc and a persistent steep radio spectrum with moderate flux-density variability. Conclusions. PKS2004447 appears to be a unique member of the gamma-NLS1 sample. It exhibits blazar-like features, such as a flat featureless X-ray spectrum and a core-dominated, one-sided parsec-scale jet with indications for relativistic beaming. However, the data also reveal properties atypical for blazars, such as a radio spectrum and large-scale size consistent with compact-steep-spectrum (CSS) objects, which are usually associated with young radio sources. These characteristics are unique among all gamma-NLS1s and extremely rare among gamma-ray-loud AGN.
On-line data analysis and monitoring for H1 drift chambers
NASA Astrophysics Data System (ADS)
Düllmann, Dirk
1992-05-01
The on-line monitoring, slow control and calibration of the H1 central jet chamber uses a VME multiprocessor system to perform the analysis and a connected Macintosh computer as graphical interface to the operator on shift. Task of this system are: - analysis of event data including on-line track search, - on-line calibration from normal events and testpulse events, - control of the high voltage and monitoring of settings and currents, - monitoring of temperature, pressure and mixture of the chambergas. A program package is described which controls the dataflow between data aquisition, differnt VME CPUs and Macintosh. It allows to run off-line style programs for the different tasks.
Results of the performance verification of the CoaguChek XS system.
Plesch, W; Wolf, T; Breitenbeck, N; Dikkeschei, L D; Cervero, A; Perez, P L; van den Besselaar, A M H P
2008-01-01
This is the first paper reporting a performance verification study of a point-of-care (POC) monitor for prothrombin time (PT) testing according to the requirements given in chapter 8 of the International Organization for Standardization (ISO) 17593:2007 standard "Clinical laboratory testing and in vitro medical devices - Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy". The monitor under investigation was the new CoaguChek XS system which is designed for use in patient self testing. Its detection principle is based on the amperometric measurement of the thrombin activity generated by starting the coagulation cascade using a recombinant human thromboplastin. The system performance verification study was performed at four study centers using venous and capillary blood samples on two test strip lots. Laboratory testing was performed from corresponding frozen plasma samples with six commercial thromboplastins. Samples from 73 normal donors and 297 patients on oral anticoagulation therapy were collected. Results were assessed using a refined data set of 260 subjects according to the ISO 17593:2007 standard. Each of the two test strip lots met the acceptance criteria of ISO 17593:2007 versus all thromboplastins (bias -0.19 to 0.18 INR; >97% of data within accuracy limits). The coefficient of variation for imprecision of the PT determinations in INR ranged from 2.0% to 3.2% in venous, and from 2.9% to 4.0% in capillary blood testing. Capillary versus venous INR data showed agreement of results with regression lines equal to the line of identity. The new system demonstrated a high level of trueness and accuracy, and low imprecision in INR testing. It can be concluded that the CoaguChek XS system complies with the requirements in chapter 8 of the ISO standard 17593:2007.
Eggenreich, Britta; Rajamanickam, Vignesh; Wurm, David Johannes; Fricke, Jens; Herwig, Christoph; Spadiut, Oliver
2017-08-01
Cell disruption is a key unit operation to make valuable, intracellular target products accessible for further downstream unit operations. Independent of the applied cell disruption method, each cell disruption process must be evaluated with respect to disruption efficiency and potential product loss. Current state-of-the-art methods, like measuring the total amount of released protein and plating-out assays, are usually time-delayed and involve manual intervention making them error-prone. An automated method to monitor cell disruption efficiency at-line is not available to date. In the current study we implemented a methodology, which we had originally developed to monitor E. coli cell integrity during bioreactor cultivations, to automatically monitor and evaluate cell disruption of a recombinant E. coli strain by high-pressure homogenization. We compared our tool with a library of state-of-the-art methods, analyzed the effect of freezing the biomass before high-pressure homogenization and finally investigated this unit operation in more detail by a multivariate approach. A combination of HPLC and automated data analysis describes a valuable, novel tool to monitor and evaluate cell disruption processes. Our methodology, which can be used both in upstream (USP) and downstream processing (DSP), describes a valuable tool to evaluate cell disruption processes as it can be implemented at-line, gives results within minutes after sampling and does not need manual intervention.
Van Kessel, J S; Karns, J S; Wolfgang, D R; Hovingh, E; Jayarao, B M; Van Tassell, C P; Schukken, Y H
2008-10-01
Although dairy cattle are known reservoirs for salmonellae, cattle that are shedding this organism are often asymptomatic and difficult to identify. A dairy herd that was experiencing a sustained, subclinical outbreak of Salmonella enterica subsp. enterica Cerro was monitored for 2 years. Fecal samples from the lactating cows were collected every 6 to 8 weeks and tested for the presence of Salmonella. Fecal prevalence of Salmonella fluctuated throughout the observation period and ranged from 8 to 88%. Manure composites and water trough samples were collected along with the fecal samples, and bulk milk and milk filters were cultured for the presence of Salmonella on a weekly basis. Over 90% of the manure composites--representing high-animal-traffic areas-were positive at each sampling. Salmonella was detected in 11% of milk samples and in 66% of the milk filters. Results of weekly bulk milk quality testing (i.e., bulk tank somatic cell score, standard plate count, preliminary incubation count) were typically well within acceptable ranges. Milk quality variables had low correlations with herd Salmonella fecal prevalence. When observed over time, sampling period average prevalence of Salmonella in milk filters closely paralleled fecal prevalence of Salmonella in the herd. Based on results of this study, milk filters appear to be an effective method for monitoring shedding prevalence at the herd level. In-line filter testing is also a more sensitive measure of Salmonella, and perhaps other pathogens, in raw milk than testing the milk alone.
The Lick AGN Monitoring Project 2016: Extending Reverberation Mapping to Higher Luminosity AGNs
NASA Astrophysics Data System (ADS)
U, Vivian; LAMP2016 Collaboration
2017-01-01
The technique of reverberation mapping has been used to estimate virial black hole masses and, more fundamentally, to probe the broad line region structure in Seyfert I galaxies. Efforts from the previous Lick AGN Monitoring Project (LAMP) campaigns and other studies to date have culminated in a large sample of reverberation mapped AGNs and measurements of their black hole masses, which in turn enabled major improvement to various AGN scaling relations. However, the high-luminosity end of such relations remains poorly constrained; this is because of observational challenges presented by the weaker continuum flux variations and longer time dilation in these sources. To this end, we have initiated a new LAMP2016 campaign to target AGNs with luminosities of 10^44 erg/s, with predicted H-beta lags of ~20 - 60 days or black hole masses of 10^7 - 10^8.5 Msun. Designed to monitor ~20 AGNs biweekly from Spring 2016 through Winter 2017 with the Kast spectrograph on the 3-m Shane Telescope at Lick Observatory, we aim to probe luminosity-dependent trends in broad line region structure and dynamics, improve calibrations for single-epoch estimates of high-redshift quasar black hole masses, and test photoionization models for the radially-stratified structure of the broad line region. In this talk, I will present the overview and scope of LAMP2016 and show preliminary results from our ongoing campaign.
Takahashi, Maria Beatriz; Leme, Jaci; Caricati, Celso Pereira; Tonso, Aldo; Fernández Núñez, Eutimio Gustavo; Rocha, José Celso
2015-06-01
Currently, mammalian cells are the most utilized hosts for biopharmaceutical production. The culture media for these cell lines include commonly in their composition a pH indicator. Spectroscopic techniques are used for biopharmaceutical process monitoring, among them, UV-Vis spectroscopy has found scarce applications. This work aimed to define artificial neural networks architecture and fit its parameters to predict some nutrients and metabolites, as well as viable cell concentration based on UV-Vis spectral data of mammalian cell bioprocess using phenol red in culture medium. The BHK-21 cell line was used as a mammalian cell model. Off-line spectra of supernatant samples taken from batches performed at different dissolved oxygen concentrations in two bioreactor configurations and with two pH control strategies were used to define two artificial neural networks. According to absolute errors, glutamine (0.13 ± 0.14 mM), glutamate (0.02 ± 0.02 mM), glucose (1.11 ± 1.70 mM), lactate (0.84 ± 0.68 mM) and viable cell concentrations (1.89 10(5) ± 1.90 10(5) cell/mL) were suitably predicted. The prediction error averages for monitored variables were lower than those previously reported using different spectroscopic techniques in combination with partial least squares or artificial neural network. The present work allows for UV-VIS sensor development, and decreases cost related to nutrients and metabolite quantifications.
Nonlinearity and seasonal bias in an index of brushtail possum abundance
Forsyth, D.M.; Link, W.A.; Webster, R.; Nugent, G.; Warburton, B.
2005-01-01
Introduced brushtail possums (Trichosurus vulpecula) are a widespread pest of conservation and agriculture in New Zealand, and considerable effort has been expended controlling populations to low densities. A national protocol for monitoring the abundance of possums, termed trap catch index (TCI), was adopted in 1996. The TCI requires that lines of leghold traps set at 20-m spacing are randomly located in a management area. The traps are set for 3 fine nights and checked daily, and possums are killed and traps reset. The TCI is the mean percentage of trap nights that possums were caught, corrected for sprung traps and nontarget captures, with trap line as the sampling unit. We studied I forest and I farmland area in the North Island, New Zealand, to address concerns that TCI estimates may not be readily comparable because of seasonal changes in the capture probability of possums. We located blocks of 6 trap lines at each area and randomly trapped I line in each block in 3 seasons (summer, winter, and spring) in 2000 and 2001. We developed a model to allow for variation in local population size and nightly capture probability, and fitted the model using the Bayesian analysis software BUGS. Capture probability declined with increasing abundance of possums, generating a nonlinear TCI. Capture probability in farmland was lower during spring relative to winter and summer, and to forest during summer. In the absence of a proven and cost-effective alternative, our results support the continued use of the TCI for monitoring the abundance of possums in New Zealand. Seasonal biases in the TCI should be minimized by conducting repeat sampling in the same season.
Probing the central engine and environment of AGN using ARIES 1.3-m and 3.6-m telescopes
NASA Astrophysics Data System (ADS)
Chand, Hum; Rakshit, Suvendu; Jalan, Priyanka; Ojha, Vineet; Srianand, Raghunathan; Vivek, Mariappan; Mishra, Sapna; Omar, Amitesh; Kumar, Parveen; Joshi, Ravi; Gopal-Krishna; Kumar, Rathna
2018-04-01
We discuss three long term observational programmes to probe the central engine and environment of active galactic nuclei (AGN) using the recently installed ARIES 1.3-m and 3.6-m telescopes. The first programme is on the photometric reverberation mapping of low luminosity AGN by mainly using the ARIES 1.3-m telescope. The major impact of this programme other than to estimate the black hole mass will be to extend the broad line region (BLR) radius-luminosity (RBLR-LAGN) relation to the unexplored low luminosity regime, and to constrain the AGN broad line region geometry. The second programme is to use long slit spectroscopy on the ARIES 3.6-m telescope to discover new high redshift quasar pairs with angular separation less than 1-arcmin. Here, the background QSOs sight-line will be used to probe the environment of the foreground QSOs at kpc-Mpc scales. The major impact of this programme will be on the discovery of new pairs which have been missed in the SDSS survey due to fiber collision below 1-arcmin separation, and use them to understand about any excess overdensity around the QSO, any anisotropic emission of QSOs, and/or any episodic activity of QSOs. The third programme is related to spectral variability studies of the C IV broad absorption line (BAL) QSOs, based on low resolution spectroscopy using the ARIES 3.6-m telescope. Here, those most interesting cases will be monitored, where the BAL flow emerges afresh or disappears completely in the C IV trough of BAL QSOs sample as seen in SDSS multi-epoch observations. Continuous monitoring of such a sample will be important for our understanding of the nature and origin of the flow, along with their stability and dynamical evolution.
Ion-selective optical sensor for continuous on-line monitoring of dialysate sodium during dialysis
NASA Astrophysics Data System (ADS)
Sharma, Manoj K.; Frijns, Arjan J. H.; Mandamparambil, Rajesh; Kooman, Jeroen P.; Smeulders, David M. J.
2017-02-01
Patients with end stage renal disease are dependent on dialysis. In most outpatient centers, the dialysate is prepared with a fixed electrolyte concentration without taking into account the inter-individual differences of essential electrolytes (sodium, potassium and calcium). This one-size fits all approach can lead to acute and chronic cardiovascular complications in dialysis patients. On-line monitoring of these essential electrolytes is an important physiological step towards patient specific dialysate leading to individualized treatment. Currently, changes in electrolyte concentrations are indirectly measured by conductivity measurements, which are not ion- specific. In this paper, we present a novel optical sensor for on-line monitoring of sodium concentrations in dialysate. This sensor is ion-specific and can detect up to a single ion. The working principle is based on the selective fluorescence quenching of photo-induced electron transfer (PET) molecules. The PET molecules when complexed with sodium ions start fluorescing upon laser excitation. The emission intensity is directly correlated to the sodium concentration. To prove the working principle, a micro-optofluidic device has been fabricated in polydimethylsiloxane (PDMS) with integrated optical fibers for fluorescence light collection. The PET molecules are covalently grafted in the PDMS microchannel for continuous monitoring of the sodium dialysate concentrations. The experimental setup consists of a laser module (λ=450nm) operating at 4.5mW, a syringe pump to precisely control the sample flow and a spectrometer for fluorescence collection. The performance of the sensor has been evaluated for sodium ions ranging from 0-50mM. A clear signal and good response time was observed.
Kim, Chansik; Ryu, Hong-Duck; Chung, Eu Gene; Kim, Yongseok
2018-05-01
The use of antibiotics and their occurrence in the environment have received significant attention in recent years owing to the generation of antibiotic-resistant bacteria. Antibiotic residues in water near livestock farming areas should be monitored to establish effective strategies for reducing the use of veterinary antibiotics. However, environmental water contamination resulting from veterinary antibiotics has not been studied extensively. In this work, we developed an analytical method for the simultaneous determination of multiple classes of veterinary antibiotic residues in environmental water using on-line solid-phase extraction (SPE)-high performance liquid chromatography (HPLC)-high resolution mass spectrometry (HRMS). Eighteen popular antibiotics (eight classes) were selected as target analytes based on veterinary antibiotics sales in South Korea in 2015. The developed method was validated by calibration-curve linearities, precisions, relative recoveries, and method detection limits (MDLs)/limits of quantification (LOQs) of the selected antibiotics, and applied to the analysis of environmental water samples (groundwater, river water, and wastewater-treatment-plant effluent). All calibration curves exhibited r 2 > 0.995 with MDLs ranging from 0.2 to 11.9 ng/L. Relative recoveries were between 50 and 150% with coefficients of variation below 20% for all analytes (spiked at 500 ng/L) in groundwater and river water samples. Relative standard deviations (RSDs) of standard-spiked samples were lower than 7% for all antibiotics. The on-line SPE system eliminates human-based SPE errors and affords excellent method reproducibility. Amoxicillin, ampicillin, clopidol, fenbendazole, flumequine, lincomycin, sulfadiazine, and trimethoprim were detected in environmental water samples in concentrations ranging from 1.26 to 127.49 ng/L. The developed method is a reliable analytical technique for the potential routine monitoring of veterinary antibiotics. Copyright © 2018 Elsevier B.V. All rights reserved.
Hyperspectral imaging for diagnosis and quality control in agri-food and industrial sectors
NASA Astrophysics Data System (ADS)
García-Allende, P. Beatriz; Conde, Olga M.; Mirapeix, Jesus; Cobo, Adolfo; Lopez-Higuera, Jose M.
2010-04-01
Optical spectroscopy has been utilized in various fields of science, industry and medicine, since each substance is discernible from all others by its spectral properties. However, optical spectroscopy traditionally generates information on the bulk properties of the whole sample, and mainly in the agri-food industry some product properties result from the heterogeneity in its composition. This monitoring is considerably more challenging and can be successfully achieved by the so-called hyperspectral imaging technology, which allows the simultaneous determination of the optical spectrum and the spatial location of an object in a surface. In addition, it is a nonintrusive and non-contact technique which gives rise to a great potential for industrial applications and it does not require any particular preparation of the samples, which is a primary concern in food monitoring. This work illustrates an overview of approaches based on this technology to address different problems in agri-food and industrial sectors. The hyperspectral system was originally designed and tested for raw material on-line discrimination, which is a key factor in the input stages of many industrial sectors. The combination of the acquisition of the spectral information across transversal lines while materials are being transported on a conveyor belt, and appropriate image analyses have been successfully validated in the tobacco industry. Lastly, the use of imaging spectroscopy applied to online welding quality monitoring is discussed and compared with traditional spectroscopic approaches in this regard.
SPECTROSCOPIC ONLINE MONITORING FOR PROCESS CONTROL AND SAFEGUARDING OF RADIOCHEMICAL STREAMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryan, Samuel A.; Levitskaia, Tatiana G.
2013-09-29
There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the used nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved used nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. This paper summarizes application of the absorption and vibrational spectroscopicmore » techniques supplemented by physicochemical measurements for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and spectrophotometric techniques for online real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. These techniques demonstrate robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. Satisfactory prediction of the analytes concentrations in these preliminary experiments warrants further development of the spectroscopy-based methods for radiochemical process control and safeguarding. Additionally, the ability to identify material intentionally diverted from a liquid-liquid extraction contactor system was successfully tested using on-line process monitoring as a means to detect the amount of material diverted. A chemical diversion and detection from a liquid-liquid extraction scheme was demonstrated using a centrifugal contactor system operating with the simulant PUREX extraction system of Nd(NO3)3/nitric acid aqueous phase and TBP/n-dodecane organic phase. During a continuous extraction experiment, a portion of the feed from a counter-current extraction system was diverted while the spectroscopic on-line process monitoring system was simultaneously measuring the feed, raffinate and organic products streams. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from the known mass of sample directly taken (diverted) from system feed solution.« less
Noninvasive monitoring of plasma L-dopa concentrations using sweat samples in Parkinson's disease.
Tsunoda, Makoto; Hirayama, Masaaki; Tsuda, Takao; Ohno, Kinji
2015-03-10
L-dopa (l-3,4-dihydroxyphenylalanine) is commonly used for treating Parkinson's disease (PD). However, regardless of its prominent effect, therapeutic range of L-dopa narrows down with disease progression, which leads to development of motor complications including wearing off and dyskinesias. In addition, intestinal absorption of L-dopa is inversely correlated with the amount of oral protein intake, and shows intra- and inter-day variability. Hence, frequent monitoring of plasma L-dopa concentrations is beneficial, but frequent venipuncture imposes physical and psychological burdens on patients with PD. We investigated the usefulness of sweat samples instead of plasma samples for monitoring L-dopa concentrations. With a monolithic silica disk-packed spin column and the high-performance liquid chromatography-electrochemical detection system, L-dopa in sweat samples was successfully quantified and analyzed in 23 PD patients. We found that the Pearson's correlation coefficient of the plasma and sweat l-dopa concentrations was 0.678. Although the disease durations and severities were not correlated with the deviation of the actual sweat L-dopa concentrations from the fitted line, acquisition of the sweat samples under a stable condition was technically difficult in severely affected patients. The deviations may also be partly accounted for by skin permeability of L-dopa. Measuring L-dopa concentrations in sweat is suitable to get further insights into the L-dopa metabolism. Copyright © 2015 Elsevier B.V. All rights reserved.
Pereira, André M P T; Silva, Liliana J G; Lino, Celeste M; Meisel, Leonor M; Pena, Angelina
2016-02-01
In line with the Directive 2013/39/EU the most representative surface waters, regarding pharmaceuticals contamination, were selected based on a Portuguese nationwide monitoring exercise. To meet this purpose, and given that wastewater treatment plants (WWTPs) are regarded as the major point sources of pharmaceuticals environmental contamination, the occurrence, fate and environmental risk assessment (ERA) of eleven of the most consumed pharmaceuticals, belonging to several therapeutic classes were assessed in 15 WWTPs (influents (WWIs) and effluents (WWEs)), from five different regions during one year (4 sampling campaigns). Results showed that all samples were contaminated with at least 1, and up to 8 from the 11 targeted pharmaceuticals. The highest concentrations observed were 150 and 33 μg L(-1) for WWI and WWE, respectively. Regarding temporal and spacial influence, winter, Alentejo, Algarve and Center regions presented higher mass loads. The ERA posed by 7 of the selected pharmaceuticals presented a risk quotient higher than 1 to the three trophic levels. Our findings highlighted that the rivers Mondego, Tagus, Ave, Trancão, Fervença and Xarrama should be selected as surface water monitoring stations. This study gives a good overview on pharmaceuticals contamination in WWTPs and its impact on surface waters in Portugal. Thus, a more integrative approach to rank and prioritize pharmaceuticals, based on an integrated assessment of ERA and exposure of surface water, was provided to support the future selection of the 6 most representative monitoring stations in Portugal, as required by the above mentioned directive. Copyright © 2015 Elsevier Ltd. All rights reserved.
van den Berg, Frans; Racher, Andrew J.; Martin, Elaine B.; Jaques, Colin
2017-01-01
Cell culture process development requires the screening of large numbers of cell lines and process conditions. The development of miniature bioreactor systems has increased the throughput of such studies; however, there are limitations with their use. One important constraint is the limited number of offline samples that can be taken compared to those taken for monitoring cultures in large‐scale bioreactors. The small volume of miniature bioreactor cultures (15 mL) is incompatible with the large sample volume (600 µL) required for bioanalysers routinely used. Spectroscopy technologies may be used to resolve this limitation. The purpose of this study was to compare the use of NIR, Raman, and 2D‐fluorescence to measure multiple analytes simultaneously in volumes suitable for daily monitoring of a miniature bioreactor system. A novel design‐of‐experiment approach is described that utilizes previously analyzed cell culture supernatant to assess metabolite concentrations under various conditions while providing optimal coverage of the desired design space. Multivariate data analysis techniques were used to develop predictive models. Model performance was compared to determine which technology is more suitable for this application. 2D‐fluorescence could more accurately measure ammonium concentration (RMSECV 0.031 g L−1) than Raman and NIR. Raman spectroscopy, however, was more robust at measuring lactate and glucose concentrations (RMSECV 1.11 and 0.92 g L−1, respectively) than the other two techniques. The findings suggest that Raman spectroscopy is more suited for this application than NIR and 2D‐fluorescence. The implementation of Raman spectroscopy increases at‐line measuring capabilities, enabling daily monitoring of key cell culture components within miniature bioreactor cultures. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:337–346, 2017 PMID:28271638
Horner, Nolan S; Beauchemin, Diane
2012-03-02
A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice. Copyright © 2011 Elsevier B.V. All rights reserved.
Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J
2012-01-01
Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers' performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria and elsewhere to improve service delivery.
Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J.
2012-01-01
Background Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers’ performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. Methods In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Findings Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. Conclusion There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria and elsewhere to improve service delivery. PMID:22984555
Gupta, Soham; Palchaudhuri, Riya; Neogi, Ujjwal; Srinivasa, Hiresave; Ashorn, Per; De Costa, Ayesha; Källander, Clas; Shet, Anita
2016-01-27
To evaluate the performance and cost of an HIV reverse transcriptase-enzyme activity (HIV-RT) assay in comparison to an HIV-1 RNA assay for routine viral load monitoring in resource limited settings. A cohort-based longitudinal study. Two antiretroviral therapy (ART) centres in Karnataka state, South India, providing treatment under the Indian AIDS control programme. A cohort of 327 HIV-1-infected Indian adult patients initiating first-line ART. Performance and cost of an HIV-RT assay (ExaVir Load V3) in comparison to a gold standard HIV-1 RNA assay (Abbott m2000rt) in a cohort of 327 Indian patients before (WK00) and 4 weeks (WK04) after initiation of first-line therapy. Plasma viral load was determined by an HIV-1 RNA assay and an HIV-RT assay in 629 samples (302 paired samples and 25 single time point samples at WK00) obtained from 327 patients. Overall, a strong correlation of r=0.96 was observed, with good correlation at WK00 (r=0.84) and at WK04 (r=0.77). Bland-Altman analysis of all samples showed a good level of agreement with a mean difference (bias) of 0.22 log10copies/mL. The performance of ExaVir Load V3 was not negatively affected by a nevirapine/efavirenz based antiretroviral regimen. The per test cost of measuring plasma viral load by the Abbott m2000rt and ExaVir Load V3 assays in a basic lab setting was $36.4 and $16.8, respectively. The strong correlation between the HIV-RT and HIV-1 RNA assays suggests that the HIV-RT assay can be an affordable alternative option for monitoring patients on antiretroviral therapy in resource-limited settings. ISRCTN79261738. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Yang, Iseul; Kim, Ki Hun; Lee, Ju Yong; Moon, Myeong Hee
2014-01-10
A direct analytical method for high speed quantitative analysis of lipids in human blood plasma using on-line chip-type asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry (cAF4-ESI-MS/MS) with selected reaction monitoring (SRM) is described in this study. Utilizing a miniaturized cAF4 channel, high speed size separation of high density lipoproteins (HDL) and low density lipoproteins (LDL) from plasma samples can be accomplished at a microflow rate along with simultaneous desalting of lipoproteins, both of which are conducive to direct ESI of lipids in lipoproteins. This study demonstrates that the SRM method to monitor phospholipids during cAF4-ESI-MS/MS can be successfully applied to the quantitation of lipid molecules in plasma lipoproteins without the need of a separate lipid extraction process. For quantitation of lipids in HDL and LDL during cAF4-ESI-MS/MS runs, a protein standard (carbonic anhydrase, 29 kDa) was added to each plasma sample as an internal standard such that a peak intensity of y67(+5) ions, which are high abundant SRM product ions of CA, could be utilized to calculate the relative intensity of each lipid molecule. The developed method was applied to plasma samples from 10 patients with coronary artery disease (CAD) and 10 healthy control samples, and quantitative analysis of 39 lipid molecules including phosphatidylcholines, phosphatidylethanolamines, sphingomyelins, phosphatidylglycerols, and phosphatidylinositols, resulted in the selection of 13 PL species showing more than 2.5 fold difference in relative abundance (p<0.01) between the groups. The present study demonstrates a high speed analytical method for determining plasma lipid content and distribution without an organic solvent extraction of lipids from plasma. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Twelve small businesses who are developing equipment and computer programs for geophysics have won Small Business Innovative Research (SBIR) grants from the National Science Foundation for their 1989 proposals. The SBIR program was set up to encourage the private sector to undertake costly, advanced experimental work that has potential for great benefit.The geophysical research projects are a long-path intracavity laser spectrometer for measuring atmospheric trace gases, optimizing a local weather forecast model, a new platform for high-altitude atmospheric science, an advanced density logging tool, a deep-Earth sampling system, superconducting seismometers, a phased-array Doppler current profiler, monitoring mesoscale surface features of the ocean through automated analysis, krypton-81 dating in polar ice samples, discrete stochastic modeling of thunderstorm winds, a layered soil-synthetic liner base system to isolate buildings from earthquakes, and a low-cost continuous on-line organic-content monitor for water-quality determination.
Tang, Gang; Hou, Wei; Wang, Huaqing; Luo, Ganggang; Ma, Jianwei
2015-01-01
The Shannon sampling principle requires substantial amounts of data to ensure the accuracy of on-line monitoring of roller bearing fault signals. Challenges are often encountered as a result of the cumbersome data monitoring, thus a novel method focused on compressed vibration signals for detecting roller bearing faults is developed in this study. Considering that harmonics often represent the fault characteristic frequencies in vibration signals, a compressive sensing frame of characteristic harmonics is proposed to detect bearing faults. A compressed vibration signal is first acquired from a sensing matrix with information preserved through a well-designed sampling strategy. A reconstruction process of the under-sampled vibration signal is then pursued as attempts are conducted to detect the characteristic harmonics from sparse measurements through a compressive matching pursuit strategy. In the proposed method bearing fault features depend on the existence of characteristic harmonics, as typically detected directly from compressed data far before reconstruction completion. The process of sampling and detection may then be performed simultaneously without complete recovery of the under-sampled signals. The effectiveness of the proposed method is validated by simulations and experiments. PMID:26473858
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael, Buric; Jessica, Mullen; Steven, Woodruff
2012-02-24
NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented formore » spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.« less
Šatínský, Dalibor; Naibrtová, Linda; Fernández-Ramos, Carolina; Solich, Petr
2015-09-01
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100×4.6 mm), particle size 2.7 µm with mobile phase acetonitrile:water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45°C. Large volume sample injection (1500 µL) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5×4.6 mm); fused-core particle size 2.7 µm allowed effective sample preconcentration and efficient ballast sample matrix removal. The washing mobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone from the extraction to the separation column was set at 3rd min. Elution of preconcentrated insecticides from the extraction precolumn and separation on the analytical column was performed in gradient mode. Linear gradient elution started from 40% of acetonitrile at time of valve switch from SPE column (3rd min) to 95% of acetonitrile at 7th min. Synthetic dye sudan I was chosen as an internal standard. UV detection at wavelength 225 nm was used and the method reached the limits of detection (LOD) at ng mL(-1) levels for both insecticides. The method showing on-line sample pretreatment and preconcentration with highly sensitive determination of insecticides was applied for monitoring of fenoxycarb and both permethrin isomers in different surface water samples in Czech Republic. The time of whole analysis including on-line extraction, interferences removal, chromatography separation and system equilibration was less than 8 min. Copyright © 2015 Elsevier B.V. All rights reserved.
Ghader, Masoud; Shokoufi, Nader; Es-Haghi, Ali; Kargosha, Kazem
2018-04-15
Vaccine production is a biological process in which variation in time and output is inevitable. Thus, the application of Process Analytical Technologies (PAT) will be important in this regard. Headspace solid - phase microextraction (HS-SPME) coupled with GC-MS can be used as a PAT for process monitoring. This method is suitable to chemical profiling of volatile organic compounds (VOCs) emitted from microorganisms. Tetanus is a lethal disease caused by Clostridium tetani (C. tetani) bacterium and vaccination is an ultimate way to prevent this disease. In this paper, SPME fiber was used for the investigation of VOCs emerging from C. tetani during cultivation. Different types of VOCs such as sulfur-containing compounds were identified and some of them were selected as biomarkers for bioreactor monitoring during vaccine production. In the second step, the portable dynamic air sampling (PDAS) device was used as an interface for sampling VOCs by SPME fibers. The sampling procedure was optimized by face-centered central composite design (FC-CCD). The optimized sampling time and inlet gas flow rates were 10 min and 2 m L s -1 , respectively. PDAS was mounted in exhausted gas line of bioreactor and 42 samples of VOCs were prepared by SPME fibers in 7 days during incubation. Simultaneously, pH and optical density (OD) were evaluated to cultivation process which showed good correlations with the identified VOCs (>80%). This method could be used for VOCs sampling from off-gas of a bioreactor to monitoring of the cultivation process. Copyright © 2018. Published by Elsevier B.V.
Coolant monitoring apparatus for nuclear reactors
Tokarz, Richard D.
1983-01-01
A system for monitoring coolant conditions within a pressurized vessel. A length of tubing extends outward from the vessel from an open end containing a first line restriction at the location to be monitored. The flowing fluid is cooled and condensed before passing through a second line restriction. Measurement of pressure drop at the second line restriction gives an indication of fluid condition at the first line restriction. Multiple lengths of tubing with open ends at incremental elevations can measure coolant level within the vessel.
Accelerated radiation damage test facility using a 5 MV tandem ion accelerator
NASA Astrophysics Data System (ADS)
Wady, P. T.; Draude, A.; Shubeita, S. M.; Smith, A. D.; Mason, N.; Pimblott, S. M.; Jimenez-Melero, E.
2016-01-01
We have developed a new irradiation facility that allows to perform accelerated damage tests of nuclear reactor materials at temperatures up to 400 °C using the intense proton (<100 μA) and heavy ion (≈10 μA) beams produced by a 5 MV tandem ion accelerator. The dedicated beam line for radiation damage studies comprises: (1) beam diagnosis and focusing optical components, (2) a scanning and slit system that allows uniform irradiation of a sample area of 0.5-6 cm2, and (3) a sample stage designed to be able to monitor in-situ the sample temperature, current deposited on the sample, and the gamma spectrum of potential radio-active nuclides produced during the sample irradiation. The beam line capabilities have been tested by irradiating a 20Cr-25Ni-Nb stabilised stainless steel with a 3 MeV proton beam to a dose level of 3 dpa. The irradiation temperature was 356 °C, with a maximum range in temperature values of ±6 °C within the first 24 h of continuous irradiation. The sample stage is connected to ground through an electrometer to measure accurately the charge deposited on the sample. The charge can be integrated in hardware during irradiation, and this methodology removes uncertainties due to fluctuations in beam current. The measured gamma spectrum allowed the identification of the main radioactive nuclides produced during the proton bombardment from the lifetimes and gamma emissions. This dedicated radiation damage beam line is hosted by the Dalton Cumbrian Facility of the University of Manchester.
A collaborative effort to monitor the upper Mississippi River watershed using On-line Toxicity Monitors (OTMs) is underway with three sites currently deployed and several more at various stages of development. Federal, State, and Local, agencies as well as utilities and Universi...
Low-cost wireless voltage & current grid monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hines, Jacqueline
This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distributionmore » grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.« less
NASA Astrophysics Data System (ADS)
Su, Huaizhi; Li, Hao; Kang, Yeyuan; Wen, Zhiping
2018-02-01
Seepage is one of key factors which affect the levee engineering safety. The seepage danger without timely detection and rapid response may likely lead to severe accidents such as seepage failure, slope instability, and even levee break. More than 90 percent of levee break events are caused by the seepage. It is very important for seepage behavior identification to determine accurately saturation line in levee engineering. Furthermore, the location of saturation line has a major impact on slope stability in levee engineering. Considering the structure characteristics and service condition of levee engineering, the distributed optical fiber sensing technology is introduced to implement the real-time observation of saturation line in levee engineering. The distributed optical fiber temperature sensor system (DTS)-based monitoring principle of saturation line in levee engineering is investigated. An experimental platform, which consists of DTS, heating system, water-supply system, auxiliary analysis system and levee model, is designed and constructed. The monitoring experiment of saturation line in levee model is implemented on this platform. According to the experimental results, the numerical relationship between moisture content and thermal conductivity in porous medium is identified. A line heat source-based distributed optical fiber method obtaining the thermal conductivity in porous medium is developed. A DTS-based approach is proposed to monitor the saturation line in levee engineering. The embedment pattern of optical fiber for monitoring saturation line is presented.
Identification of Highly Methylated Genes across Various Types of B-Cell Non-Hodgkin Lymphoma
Bethge, Nicole; Honne, Hilde; Hilden, Vera; Trøen, Gunhild; Eknæs, Mette; Liestøl, Knut; Holte, Harald; Delabie, Jan; Smeland, Erlend B.; Lind, Guro E.
2013-01-01
Epigenetic alterations of gene expression are important in the development of cancer. In this study, we identified genes which are epigenetically altered in major lymphoma types. We used DNA microarray technology to assess changes in gene expression after treatment of 11 lymphoma cell lines with epigenetic drugs. We identified 233 genes with upregulated expression in treated cell lines and with downregulated expression in B-cell lymphoma patient samples (n = 480) when compared to normal B cells (n = 5). The top 30 genes were further analyzed by methylation specific PCR (MSP) in 18 lymphoma cell lines. Seven of the genes were methylated in more than 70% of the cell lines and were further subjected to quantitative MSP in 37 B-cell lymphoma patient samples (diffuse large B-cell lymphoma (activated B-cell like and germinal center B-cell like subtypes), follicular lymphoma and Burkitt`s lymphoma) and normal B lymphocytes from 10 healthy donors. The promoters of DSP, FZD8, KCNH2, and PPP1R14A were methylated in 28%, 67%, 22%, and 78% of the 36 tumor samples, respectively, but not in control samples. Validation using a second series of healthy donor controls (n = 42; normal B cells, peripheral blood mononuclear cells, bone marrow, tonsils and follicular hyperplasia) and fresh-frozen lymphoma biopsies (n = 25), confirmed the results. The DNA methylation biomarker panel consisting of DSP, FZD8, KCNH2, and PPP1R14A was positive in 89% (54/61) of all lymphomas. Receiver operating characteristic analysis to determine the discriminative power between lymphoma and healthy control samples showed a c-statistic of 0.96, indicating a possible role for the biomarker panel in monitoring of lymphoma patients. PMID:24260260
A new tritium monitor design based on plasma source ion implantation technique
NASA Astrophysics Data System (ADS)
Nassar, Rafat Mohammad
Tritium is an important isotope of hydrogen. The availability of tritium in our environment is manifest through both natural and artificial sources. Consequently, the requirement for tritium handling and usage will continue to increase in the future. An important future contributor is nuclear fusion power plants and facilities. Essential safety regulations and procedures require effective monitoring and measurements of tritium concentrations in workplaces. The unique characteristics of tritium impose an important role on the criteria for its detection and measurement. As tritium decays by the emission of soft beta particles, maximum 18 keV, it cannot be readily detected by commonly used detectors. Specially built monitors are required. Additional complications occur due to the presence of other radioactive isotopes or ambient radiation fields and because of the high diffusivity of tritium. When it is in oxidized form it is 25000 times more hazardous biologically than when in elemental form. Therefore, contamination of the monitor is expected and compound specific monitors are important. A summary is given of the various well known methods of detecting tritium-in-air. This covers the direct as well as the indirect measuring techniques, although each has been continually improved and further developed, nevertheless, each has its own limitations. Ionization chambers cannot discriminate against airborne P emitters. Proportional counters have a narrow operating range, 3-4 decades, and have poor performance in relatively high humid environments and require a dry counting gas. Liquid scintillation counters are sensitive, but inspection of the sample is slow and they produce chemical liquid waste. A new way to improve the sensitivity of detecting tritium with plastic scintillators has been developed. The technique is based on a non-line-of-sight implantation of tritium ions into a 20 mum plastic scintillator using a plasma source ion implantation (PSII) technique, This type of source is different, superior to the line-of-sight implantation and requires no additional beam handling. It is capable of implanting ion species in a broad beam configuration into the entire surface of a target. The technique requires a special ion source with special characteristics of the type obtained from a surfatron plasma source. This ion source has a large high ion density plasma with minimum contamination and produces ions of low temperature. It was constructed to ionize the sampled air and to produce a plasma over a wide range of pressure, 4-0.1 mTorr. A plasma source ion implantation cell was designed and constructed using mathematical modeling with personal computer, to optimize the essential variables of the design and to estimate the implantation rate under different operation conditions. Also, a high voltage pulse modulator was designed and constructed to produce a series of 10 musec pulses (up to 2 MHz) with a maximum magnitude of -60 kV. The developed device was capable of ionizing air samples and implanting the resulting ions into a plastic scintillator. Two different methods to enhance the collection and deposition of the tritium ions, have been proposed and assessed. A movable prototype device for monitoring environmental tritium in air has been designed and constructed. Although this prototype was not fully tested, the primary calculations have shown that measurable concentrations of tritium ions can be collected from an air sample, with tritium activity ranging from 0.3 Bq/cm3 down to 0.03 mBq/cm3, in a short time, to the order of seconds, on-line. This sensitivity fulfills the requirement for environmental monitoring.
Wang, Dan; Singhasemanon, Nan; Goh, Kean S
2016-11-15
Pesticides are routinely monitored in surface waters and resultant data are analyzed to assess whether their uses will damage aquatic eco-systems. However, the utility of the monitoring data is limited because of the insufficiency in the temporal and spatial sampling coverage and the inability to detect and quantify trace concentrations. This study developed a novel assessment procedure that addresses those limitations by combining 1) statistical methods capable of extracting information from concentrations below changing detection limits, 2) statistical resampling techniques that account for uncertainties rooted in the non-detects and insufficient/irregular sampling coverage, and 3) multiple lines of evidence that improve confidence in the final conclusion. This procedure was demonstrated by an assessment on chlorpyrifos monitoring data in surface waters of California's Central Valley (2005-2013). We detected a significant downward trend in the concentrations, which cannot be observed by commonly-used statistical approaches. We assessed that the aquatic risk was low using a probabilistic method that works with non-detects and has the ability to differentiate indicator groups with varying sensitivity. In addition, we showed that the frequency of exceedance over ambient aquatic life water quality criteria was affected by pesticide use, precipitation and irrigation demand in certain periods anteceding the water sampling events. Copyright © 2016 Elsevier B.V. All rights reserved.
Rotation periods of open-cluster stars, 3
NASA Technical Reports Server (NTRS)
Prosser, Charles F.; Shetrone, Matthew D.; Dasgupta, Amil; Backman, Dana E.; Laaksonen, Bentley D.; Baker, Shawn W.; Marschall, Laurence A.; Whitney, Barbara A.; Kuijken, Konrad; Stauffer, John R.
1995-01-01
We present the results from a photometric monitoring program of 15 open cluster stars and one weak-lined T Tauri star during late 1993/early 1994. Several show rotators which are members of the Alpha Persei, Pleiades, and Hyades open clusters have been monitored and period estimates derived. Using all available Pleiades stars with photometric periods together with current X-ray flux measurements, we illustrate the X-ray activity/rotation relation among Pleiades late-G/K dwarfs. The data show a clear break in the rotation-activity relation around P approximately 6-7 days -- in general accordance with previous results using more heterogeneous samples of G/K stars.
Christien, F; Telling, M T F; Knight, K S; Le Gall, R
2015-05-01
A method is proposed for the monitoring of metal recrystallization using neutron diffraction that is based on the measurement of stored energy. Experiments were performed using deformed metal specimens heated in-situ while mounted at the sample position of the High Resolution Powder Diffractometer, HRPD (ISIS Facility), UK. Monitoring the breadth of the resulting Bragg lines during heating not only allows the time-dependence (or temperature-dependence) of the stored energy to be determined but also the recrystallized fraction. The analysis method presented here was developed using pure nickel (Ni270) specimens with different deformation levels from 0.29 to 0.94. In situ temperature ramping as well as isothermal annealing was undertaken. The method developed in this work allows accurate and quantitative monitoring of the recrystallization process. The results from neutron diffraction are satisfactorily compared to data obtained from calorimetry and hardness measurements.
Cobbledick, Jeffrey; Nguyen, Alexander; Latulippe, David R
2014-07-01
The current challenges associated with the design and operation of net-energy positive wastewater treatment plants demand sophisticated approaches for the monitoring of polymer-induced flocculation. In anaerobic digestion (AD) processes, the dewaterability of the sludge is typically assessed from off-line lab-bench tests - the capillary suction time (CST) test is one of the most common. Focused beam reflectance measurement (FBRM) is a promising technique for real-time monitoring of critical performance attributes in large scale processes and is ideally suited for dewatering applications. The flocculation performance of twenty-four cationic polymers, that spanned a range of polymer size and charge properties, was measured using both the FBRM and CST tests. Analysis of the data revealed a decreasing monotonic trend; the samples that had the highest percent removal of particles less than 50 microns in size as determined by FBRM had the lowest CST values. A subset of the best performing polymers was used to evaluate the effects of dosage amount and digestate sources on dewatering performance. The results from this work show that FBRM is a powerful tool that can be used for optimization and on-line monitoring of dewatering processes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ge, Liya; Yong, Jean Wan Hong; Tan, Swee Ngin; Yang, Xin Hao; Ong, Eng Shi
2006-11-10
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is described for the separation and determination of six cytokinin nucleotides in coconut water. The best CZE separation for the six cytokinin nucleotide standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) methanol with an applied gradient separation voltage (25 kV for 32 min, and then a linear gradient to 30 kV in 5 min, finally 30 kV to the end of separation) in less than 60 min. MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity and sensitivity for the cytokinin nucleotides. The combined use of on-line sample stacking and CZE-MS/MS achieved limits of detection (LODs) in the range of 0.06-0.19 microM for the six cytokinin nucleotides at a signal-to-noise ratio of 3. Furthermore, a novel dual-step SPE procedure was developed for the pre-concentration and purification of cytokinin nucleotides using Oasis HLB and Oasis MAX cartridges. The recoveries of the cytokinin nucleotides after the dual-step SPE were in the range of 44-71%. The combination of off-line SPE, on-line sample stacking and CZE-MS/MS approach was successfully applied to screen for endogenous cytokinin nucleotides present in coconut water sample. trans-Zeatin riboside-5'-monophosphate (ZMP) was detected and quantified in coconut water by CZE-MS/MS after SPE and on-line sample stacking.
GBM Observations of Terrestrial Gamma-Ray Flashes
NASA Technical Reports Server (NTRS)
Briggs, M. S.; Fishman, G. J.; Connaughton, V.; Bhat, P. N.; Paciesas, W. S.; Preece, R. D.; Wilson-Hodge, C.; Chaplin, V. L.; Kippen, R. M.; vonKienlin, A.;
2010-01-01
The TGF detection rate of Gamma-ray Burst Monitor (GBM) has been increased twice since launch. The most recent improvement is from a new operating mode in which data for individual photons are down-linked for selected portions of the orbit, enabling a more sensitive ground-based search for TGFs. The new search has increased the TGF detection rate and is finding TGFs more than five times fainter than the TGFs of the previous GBM sample. We summarize the properties of the original GBM TGF sample and compare to the less intense TGFs now being detected. In addition to gamma-ray TGFs, GBM is observing distant TGFs from the propagation of charged particles along geomagnetic field lines. Strong 511 keV annihilation lines have been observed, demonstrating that both electrons and positrons are present in the particle beams. Spectral fits to these electron/positron TGFs will be shown.
Monitoring of Cr, Cu, Pb, V and Zn in polluted soils by laser induced breakdown spectroscopy (LIBS).
Dell'Aglio, Marcella; Gaudiuso, Rosalba; Senesi, Giorgio S; De Giacomo, Alessandro; Zaccone, Claudio; Miano, Teodoro M; De Pascale, Olga
2011-05-01
Laser Induced Breakdown Spectroscopy (LIBS) is a fast and multi-elemental analytical technique particularly suitable for the qualitative and quantitative analysis of heavy metals in solid samples, including environmental ones. Although LIBS is often recognised in the literature as a well-established analytical technique, results about quantitative analysis of elements in chemically complex matrices such as soils are quite contrasting. In this work, soil samples of various origins have been analyzed by LIBS and data compared to those obtained by Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The emission intensities of one selected line for each of the five analytes (i.e., Cr, Cu, Pb, V, and Zn) were normalized to the background signal, and plotted as a function of the concentration values previously determined by ICP-OES. Data showed a good linearity for all calibration lines drawn, and the correlation between ICP-OES and LIBS was confirmed by the satisfactory agreement obtained between the corresponding values. Consequently, LIBS method can be used at least for metal monitoring in soils. In this respect, a simple method for the estimation of the soil pollution degree by heavy metals, based on the determination of an anthropogenic index, was proposed and determined for Cr and Zn.
Chao, Yu-Ying; Jian, Zhi-Xuan; Tu, Yi-Ming; Wang, Hsaio-Wen; Huang, Yeou-Lih
2013-06-07
In this study, we employed a novel on-line method, push/pull perfusion hollow-fiber liquid-phase microextraction (PPP-HF-LPME), to extract 4-tert-butylphenol, 2,4-di-tert-butylphenol, 4-n-nonylphenol, and 4-n-octylphenol from river and tap water samples; we then separated and quantified the extracted analytes through high-performance liquid chromatography (HPLC). Using this approach, we overcame the problem of fluid loss across the porous HF membrane to the donor phase, permitting on-line coupling of HF-LPME to HPLC. In our PPP-HF-LPME system, we used a push/pull syringe pump as the driving source to perfuse the acceptor phase, while employing a heating mantle and an ultrasonic probe to accelerate mass transfer. We optimized the experimental conditions such as the nature of the HF supported intermediary phase and the acceptor phase, the composition of the donor and acceptor phases, the sample temperature, and the sonication conditions. Our proposed method provided relative standard deviations of 3.1-6.2%, coefficients of determination (r(2)) of 0.9989-0.9998, and limits of detection of 0.03-0.2 ng mL(-1) for the analytes under the optimized conditions. When we applied this method to analyses of river and tap water samples, our results confirmed that this microextraction technique allows reliable monitoring of alkylphenols in water samples.
Kremr, Daniel; Cocovi-Solberg, David J; Bajerová, Petra; Ventura, Karel; Miró, Manuel
2017-05-01
A novel fully automated in-vitro oral dissolution test assay as a front-end to liquid chromatography has been developed and validated for on-line chemical profiling and monitoring of temporal release profiles of three caffeoylquinic acid (CQA) isomers, namely, 3-CQA,4-CQA and 5-CQA, known as chlorogenic acids, in dietary supplements. Tangential-flow filtration is harnessed as a sample processing approach for on-line handling of CQA containing extracts of hard gelatin capsules and introduction of protein-free samples into the liquid chromatograph. Oral bioaccessibility/dissolution test assays were performed at 37.0±0.5°C as per US Pharmacopeia recommendations using pepsin with activity of ca. 749,000 USP units/L in 0.1mol/L HCl as the extraction medium and a paddle apparatus stirred at 50rpm. CQA release rates and steady-state dissolution conditions were determined accurately by fitting the chromatographic datasets, namely, the average cumulative concentrations of bioaccessible pools of every individual isomer monitored during 200min, with temporal resolutions of ≥10min, to a first-order dissolution kinetic model. Distinct solid-to-liquid phase ratios in the mimicry of physiological extraction conditions were assessed. Relative standard deviations for intra-day repeatability and inter-day intermediate precision of 5-CQA within the 5-40µg/mL concentration range were <3.4% and <5.5%, respectively. Trueness of the automatic flow method for determination of 5-CQA released from dietary supplements in gastric fluid surrogate was demonstrated by spike recoveries, spanning from 91.5-104.0%, upon completion of the dissolution process. The proposed hyphenated setup was resorted for evaluating potential differences in dissolution profiles and content of the three most abundant chlorogenic acid isomers in dietary supplements from varied manufacturers. Copyright © 2016 Elsevier B.V. All rights reserved.
Möltgen, C-V; Puchert, T; Menezes, J C; Lochmann, D; Reich, G
2012-04-15
Film coating of tablets is a multivariate pharmaceutical unit operation. In this study an innovative in-line Fourier-Transform Near-Infrared Spectroscopy (FT-NIRS) application is described which enables real-time monitoring of a full industrial scale pan coating process of heart-shaped tablets. The tablets were coated with a thin hydroxypropyl methylcellulose (HPMC) film of up to approx. 28 μm on the tablet face as determined by SEM, corresponding to a weight gain of 2.26%. For a better understanding of the aqueous coating process the NIR probe was positioned inside the rotating tablet bed. Five full scale experimental runs have been performed to evaluate the impact of process variables such as pan rotation, exhaust air temperature, spray rate and pan load and elaborate robust and selective quantitative calibration models for the real-time determination of both coating growth and tablet moisture content. Principal Component (PC) score plots allowed each coating step, namely preheating, spraying and drying to be distinguished and the dominating factors and their spectral effects to be identified (e.g. temperature, moisture, coating growth, change of tablet bed density, and core/coat interactions). The distinct separation of HPMC coating growth and tablet moisture in different PCs enabled a real-time in-line monitoring of both attributes. A PLS calibration model based on Karl Fischer reference values allowed the tablet moisture trajectory to be determined throughout the entire coating process. A 1-latent variable iPLS weight gain calibration model with calibration samples from process stages dominated by the coating growth (i.e. ≥ 30% of the theoretically applied amount of coating) was sufficiently selective and accurate to predict the progress of the thin HPMC coating layer. At-line NIR Chemical Imaging (NIR-CI) in combination with PLS Discriminant Analysis (PLSDA) verified the HPMC coating growth and physical changes at the core/coat interface during the initial stages of the coating process. In addition, inter- and intra-tablet coating variability throughout the process could be assessed. These results clearly demonstrate that in-line NIRS and at-line NIR-CI can be applied as complimentary PAT tools to monitor a challenging pan coating process. Copyright © 2012 Elsevier B.V. All rights reserved.
Chu, Chien; Li, Hong-Ping; Tsai, Huai-Jen
2014-01-01
Reliable animal models are invaluable for monitoring the extent of pollution in the aquatic environment. In this study, we demonstrated the potential of huORFZ, a novel transgenic zebrafish line that harbors a human upstream open reading frame of the chop gene fused with GFP reporter, as an animal model for monitoring environmental pollutants and stress-related cellular processes. When huORFZ embryos were kept under normal condition, no leaked GFP signal could be detected. When treated with hazardous chemicals, including heavy metals and endocrine-disrupting chemicals near their sublethal concentrations (LC50), huORFZ embryos exhibited different tissue-specific GFP expression patterns. For further analysis, copper (Cu2+), cadmium (Cd2+) and Chlorpyrifos were applied. Cu2+ triggered GFP responses in skin and muscle, whereas Cd2+ treatment triggered GFP responses in skin, olfactory epithelium and pronephric ducts. Moreover, fluorescence intensity, as exhibited by huORFZ embryos, was dose-dependent. After surviving treated embryos were returned to normal condition, survival rates, as well as TUNEL signals, returned to pretreatment levels with no significant morphological defects observed. Such results indicated the reversibility of treatment conditions used in this study, as long as embryos survived such conditions. Notably, GFP signals decreased along with recovery, suggesting that GFP signaling of huORFZ embryos likely reflected the overall physiological condition of the individual. To examine the performance of the huORFZ line under real-world conditions, we placed huORFZ embryos in different river water samples. We found that the huORFZ embryos correctly detected the presence of various kinds of pollutants. Based on these findings, we concluded that such uORFchop-based system can be integrated into a first-line water alarm system monitoring the discharge of hazardous pollutants. PMID:24594581
González-Andrade, Martin; Benito-Peña, Elena; Mata, Rachel; Moreno-Bondi, Maria C
2012-04-01
This paper describes the development of a novel on-line biosensor based on a fluorescently labeled human calmodulin (CaM), hCaM M124C-mBBr, immobilized on controlled-pore glass (CPG), for the analysis of trifluoroperazine (TFP); a phenothiazine drug in human urine samples. The device was automated by packing hCaM M124C-mBBr-CPG in a continuous-flow microcell connected to a monitoring system, composed of a bifurcated optical fiber coupled to a spectrofluorometer. Operating parameters of the on-line biosensor (flow rate, sample injection volume, and carrier solution and buffer pH) were studied and optimized. Under the optimal conditions, the biosensor provides a detection and a quantification limit of 0.24 and 0.52 μg mL(-1), respectively, and a dynamic range from 0.52 to 61.05 μg mL(-1) TFP (n = 5, correlation coefficient 0.998). The response time (t(100)) was shorter than 42 s (recovery time <4.5 min) and reproducibility and repeatability of the TFP measurements, within the linear response range, were lower than 1.4 and 2.7%, respectively. The device was successfully applied to the analysis of TFP in spiked human urine samples with recoveries ranging between 97 and 101% and with RSDs lower than 5.9%.
INTERNATIONAL SOURCE WATER TOXICITY MONITORING CONSORTIUM
Many researchers in the field of time-relevant, on-line toxicity monitors for source water protection believe that some mechanism to guide and prioritize research in this emerging field would be beneficial. On-line toxicity monitors are tools designed to screen water quality and ...
Bianchi, Eloisa; Lessing, Gustavo; Brina, Karisa Roxo; Angeli, Larissa; Andriguetti, Natália Bordin; Peruzzo, Jaqueline Regina Soares; do Nascimento, Carlos Augusto; Spilki, Fernando Rosado; Ziulkoski, Ana Luiza; da Silva, Luciano Basso
2017-04-01
The Sinos River is one of the most polluted rivers in Brazil. The purpose of this work was to monitor the presence of some pesticides and hydrocarbons as well as the genotoxic and cytotoxic potential on HEp-2 cells from water samples collected at seven sites in the Sinos River Basin (SRB), southern Brazil. Nine samples were taken from the three main rivers in the SRB and used as a solution to dilute the HEp-2 cell culture medium after microfiltration. Twenty-four pesticides and 19 hydrocarbons were measured. Cytotoxicity was assessed by methyl thiazolyl tetrazolium (MTT) and neutral red (NR) assays, in which cells were exposed to different concentrations of the water samples for 24 h. Genotoxicity of the microfiltrated raw water samples was assessed by comet assay after 6 and 24 h of exposure. Among the chemicals analyzed, only the 2,4-D, dichloromethane, tetrachloroethene, chloroform, bromodichloromethane, styrene, and toluene were detected, but they were all lower than the limit established by Brazilian regulations. Twenty samples from a total of 60 had a cytotoxic effect in the MTT assay and 30 in the NR assay. The comet assay indicated the presence of genotoxic substances in the water at the seven locations monitored. Temporal and spatial variation was observed in the cytotoxicity and genotoxicity assays. Results indicated that the water in all stretches of the SRB is contaminated and it can cause harmful effects to humans and to the aquatic biota. This HEp-2 cell-line approach can be an additional tool for environmental monitoring.
NASA Astrophysics Data System (ADS)
Roy, Rajat K.; Dutta, Siuli; Panda, Ashis K.; Rajinikanth, V.; Das, Swapan K.; Mitra, Amitava; Strangwood, M.; Davis, Claire L.
2018-07-01
The recovery and recrystallisation behaviours of cold rolled IF steel have been investigated by destructive (optical microscopy and hardness) and non-destructive electromagnetic sensor, (which allows direct measurement of strip samples with no surface preparation) techniques. The onset and completion of recrystallisation are clearly monitored through destructive techniques of optical microscopy and hardness measurements. The nucleation of new recrystallised grains is observed in the sample annealed at 600 °C/15 min, while completion of recrystallisation takes place at 700 °C/15 min. The destructive techniques are not very accurate in monitoring recovery, for example, changes in hardness of <20% are seen. In contrast, the magnetic properties of annealed steel show the onsets of both recovery and recrystallisation, with recovery accounting for ≈60% change in the coercivity value. Therefore, the measurement of magnetic softening through an electromagnetic sensor acts a crucial role for understanding recovery and recrystallisation behaviours of steels during industrial processing. The present investigation is aimed not only for controlling product quality but also saving characterisation time through off line monitoring during steel processing at industry.
Zhang, Qiyang; Gong, Maojun
2016-06-10
Flow-gated capillary electrophoresis (CE) coupled with microdialysis has become an important tool for in vivo bioanalytical measurements because it is capable of performing rapid and efficient separations of complex biological mixtures thus enabling high temporal resolution in chemical monitoring. However, the limit of detection (LOD) is often limited to a micro- or nano-molar range while many important target analytes have picomolar or sub-nanomolar levels in brain and other tissues. To enhance the capability of flow-gated CE for catecholamine detection, a novel and simple on-line sample preconcentration method was developed exclusively for fluorescent derivatives of catecholamines that were fluorogenically derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) in the presence of cyanide. The effective preconcentration coupled with the sensitive laser-induced fluorescence (LIF) detection lowered the LOD down to 20pM for norepinephrine (NE) and 50pM for dopamine (DA) at 3-fold of S/N ratio, and the signal enhancement was estimated to be over 100-fold relative to normal injection when standard analytes were dissolved in artificial cerebrospinal fluid (aCSF). The basic focusing principle is novel since the sample plug contains borate while the background electrolyte (BGE) is void of borate. This strategy took advantage of the complexation between diols and borate, through which one negative charge was added to the complex entity. The sample derivatization mixture was electrokinetically injected into a capillary via the flow-gated injection, and then NE and DA derivatives were selectively focused to a narrow zone by the reversible complexation. Separation of NE and DA derivatives was executed by incoming surfactants of cholate and deoxycholate mixed in the front BGE plug. This on-line preconcentration method was finally applied to the detection of DA in rat cerebrospinal fluid (CSF) via microdialysis and on-line derivatization. It is anticipated that the method would be valuable for in vivo monitoring of DA and NE in various brain regions of live animals on flow-gated CE or microchip platforms. Published by Elsevier B.V.
In-line assay monitor for uranium hexafluoride
Wallace, Steven A.
1981-01-01
An in-line assay monitor for determining the content of uranium-235 in a uranium hexafluoride gas isotopic separation system is provided which removes the necessity of complete access to the operating parameters of the system for determining the uranium-235 content. The monitor is intended for uses such as safeguard applications to assure that weapons grade uranium is not being produced in an enrichment cascade. The method and monitor for carrying out the method involve cooling of a radiation pervious chamber connected in fluid communication with the selected point in the system to withdraw a specimen and solidify the specimen in the chamber. The specimen is irradiated by means of an ionizing radiation source of energy different from that of the 185 keV gamma emissions from the uranium-235 present in the specimen. Simultaneously, the gamma emissions from the uranium-235 of the specimen and the source emissions transmitted through the sample are counted and stored in a multiple channel analyzer. The uranium-235 content of the specimen is determined from the comparison of the accumulated 185 keV energy counts and the reference energy counts. The latter is used to measure the total uranium isotopic content of the specimen. The process eliminates the necessity of knowing the system operating conditions and yet obtains the necessary data without need for large scintillation crystals and sophisticated mechanical designs.
The Transmission Channel Tower Identification and Landslide Disaster Monitoring Based on Insar
NASA Astrophysics Data System (ADS)
Li, G.; Tan, Q.; Xie, C.; Fei, X.; Ma, X.; Zhao, B.; Ou, W.; Yang, Z.; Wang, J.; Fang, H.
2018-04-01
The transmission distance of transmission lines is long, the line affected by the diversity of climate and topography of the corridors of transmission lines, differences in regional geological structure conditions, variability of rock and soil types, and the complexity of groundwater. Under the influence of extreme weather conditions (ice-covered, strong wind, etc.) and sudden geological disasters (such as mudslides, flash floods, earthquakes, etc.), catastrophic damage and basic deformation problems of the tower foundations are prone, and even tower collapse accidents occur in severe cases, which affect the safe operation of transmission lines. Monitoring the deformation of power transmission towers and surrounding grounds, it is critical to ensuring the normal operation of transmission lines by assessing and controlling potential risks in advance. In this paper, using ALOS-2 PALSAR radar satellite data, differential interferometry was used to monitor surface deformation near the Sichuan Jinsu line transmission channel. The analysis found that a significant landslide hazard was found near the transmission channel tower in Yibin-Zhaotong section of Jinsu, Sichuan Province, the cumulative deformation reaches 9cm. The results of this paper can provide new monitoring means for safety monitoring of transmission towers.
NASA Astrophysics Data System (ADS)
Travis, B. J.; Sauer, J.; Dubey, M. K.
2017-12-01
Methane (CH4) leaks from oil and gas production fields are a potentially significant source of atmospheric methane. US DOE's ARPA-E office is supporting research to locate methane emissions at 10 m size well pads to within 1 m. A team led by Aeris Technologies, and that includes LANL, Planetary Science Institute and Rice University has developed an autonomous leak detection system (LDS) employing a compact laser absorption methane sensor, a sonic anemometer and multiport sampling. The LDS system analyzes monitoring data using a convolutional neural network (cNN) to locate and quantify CH4 emissions. The cNN was trained using three sources: (1) ultra-high-resolution simulations of methane transport provided by LANL's coupled atmospheric transport model HIGRAD, for numerous controlled methane release scenarios and methane sampling configurations under variable atmospheric conditions, (2) Field tests at the METEC site in Ft. Collins, CO., and (3) Field data from other sites where point-source surface methane releases were monitored downwind. A cNN learning algorithm is well suited to problems in which the training and observed data are noisy, or correspond to complex sensor data as is typical of meteorological and sensor data over a well pad. Recent studies with our cNN emphasize the importance of tracking wind speeds and directions at fine resolution ( 1 second), and accounting for variations in background CH4 levels. A few cases illustrate the importance of sufficiently long monitoring; short monitoring may not provide enough information to determine accurately a leak location or strength, mainly because of short-term unfavorable wind directions and choice of sampling configuration. Length of multiport duty cycle sampling and sample line flush time as well as number and placement of monitoring sensors can significantly impact ability to locate and quantify leaks. Source location error at less than 10% requires about 30 or more training cases.
Applications of optical measurement technology in pollution gas monitoring at thermal power plants
NASA Astrophysics Data System (ADS)
Wang, Jian; Yu, Dahai; Ye, Huajun; Yang, Jianhu; Ke, Liang; Han, Shuanglai; Gu, Haitao; Chen, Yingbin
2011-11-01
This paper presents the work of using advanced optical measurement techniques to implement stack gas emission monitoring and process control. A system is designed to conduct online measurement of SO2/NOX and mercury emission from stacks and slipping NH3 of de-nitrification process. The system is consisted of SO2/NOX monitoring subsystem, mercury monitoring subsystem, and NH3 monitoring subsystem. The SO2/NOX monitoring subsystem is developed based on the ultraviolet differential optical absorption spectroscopy (UV-DOAS) technique. By using this technique, a linearity error less than +/-1% F.S. is achieved, and the measurement errors resulting from optical path contamination and light fluctuation are removed. Moreover, this subsystem employs in situ extraction and hot-wet line sampling technique to significantly reduce SO2 loss due to condensation and protect gas pipeline from corrosion. The mercury monitoring subsystem is used to measure the concentration of element mercury (Hg0), oxidized mercury (Hg2+), and total gaseous mercury (HgT) in the flue gas exhaust. The measurement of Hg with a low detection limit (0.1μg/m3) and a high sensitivity is realized by using cold vapor atom fluorescence spectroscopy (CVAFS) technique. This subsystem is also equipped with an inertial separation type sampling technique to prevent gas pipeline from being clogged and to reduce speciation mercury measurement error. The NH3 monitoring subsystem is developed to measure the concentration of slipping NH3 and then to help improving the efficiency of de-nitrification. The NH3 concentration as low as 0.1ppm is able to be measured by using the off-axis integrated cavity output spectroscopy (ICOS) and the tunable diode laser absorption spectroscopy (TDLAS) techniques. The problem of trace NH3 sampling loss is solved by applying heating the gas pipelines when the measurement is running.
Remote monitoring of soil moisture using airborne microwave radiometers
NASA Technical Reports Server (NTRS)
Kroll, C. L.
1973-01-01
The current status of microwave radiometry is provided. The fundamentals of the microwave radiometer are reviewed with particular reference to airborne operations, and the interpretative procedures normally used for the modeling of the apparent temperature are presented. Airborne microwave radiometer measurements were made over selected flight lines in Chickasha, Oklahoma and Weslaco, Texas. Extensive ground measurements of soil moisture were made in support of the aircraft mission over the two locations. In addition, laboratory determination of the complex permittivities of soil samples taken from the flight lines were made with varying moisture contents. The data were analyzed to determine the degree of correlation between measured apparent temperatures and soil moisture content.
A search for passive protoplanetary discs in the Taurus-Auriga star-forming region
NASA Astrophysics Data System (ADS)
Duchêne, Gaspard; Becker, Adam; Yang, Yizhe; Bouy, Hervé; De Rosa, Robert J.; Patience, Jennifer; Girard, Julien H.
2017-08-01
We conducted a 12-month monitoring campaign of 33 T Tauri stars (TTS) in Taurus. Our goal was to monitor objects that possess a disc but have a weak H α line, a common accretion tracer for young stars, in order to determine whether they host a passive circumstellar disc. We used medium-resolution optical spectroscopy to assess the accretion status of the objects and to measure the H α line. We found no convincing examples of passive discs: only transition disc and debris disc systems in our sample are non-accreting. Among accretors, we found no example of flickering accretion, leading to an upper limit of 2.2 per cent on the duty cycle of accretion gaps, assuming that all accreting TTS experience such events. When combining literature results with our observations, we found that the reliability of traditional H α-based criteria to test for accretion is high but imperfect, particularly for low-mass TTS. We found a significant correlation between stellar mass and the full width at 10 per cent of the peak (W10) of the H α line that does not seem to be related to variations in free-fall velocity. Finally, our data revealed a positive correlation between the H α equivalent width and its W10, indicative of a systematic modulation in the line profile whereby the high-velocity wings of the line are proportionally more enhanced than its core when the line luminosity increases. We argue that this supports the hypothesis that the mass accretion rate on the central star is correlated with the H α W10 through a common physical mechanism.
Jung, R.E.; Droege, S.; Sauer, J.R.; Landy, R.B.
2000-01-01
In response to concerns about amphibian declines, a study evaluating and validating amphibian monitoring techniques was initiated in Shenandoah and Big Bend National Parks in the spring of 1998. We evaluate precision, bias, and efficiency of several sampling methods for terrestrial and streamside salamanders in Shenandoah National Park and assess salamander abundance in relation to environmental variables, notably soil and water pH. Terrestrial salamanders, primarily redback salamanders (Plethodon cinereus), were sampled by searching under cover objects during the day in square plots (10 to 35 m2). We compared population indices (mean daily and total counts) with adjusted population estimates from capture-recapture. Analyses suggested that the proportion of salamanders detected (p) during sampling varied among plots, necessitating the use of adjusted population estimates. However, adjusted population estimates were less precise than population indices, and may not be efficient in relating salamander populations to environmental variables. In future sampling, strategic use of capture-recapture to verify consistency of p's among sites may be a reasonable compromise between the possibility of bias in estimation of population size and deficiencies due to inefficiency associated with the estimation of p. The streamside two-lined salamander (Eurycea bislineata) was surveyed using four methods: leaf litter refugia bags, 1 m2 quadrats, 50 x 1 m visual encounter transects, and electric shocking. Comparison of survey methods at nine streams revealed congruent patterns of abundance among sites, suggesting that relative bias among the methods is similar, and that choice of survey method should be based on precision and logistical efficiency. Redback and two-lined salamander abundance were not significantly related to soil or water pH, respectively.
Air sampling unit for breath analyzers
NASA Astrophysics Data System (ADS)
Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew
2017-11-01
The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.
NASA Technical Reports Server (NTRS)
Tiwari, Vidhu S.; Kalluru, Rajamohan R.; Yueh, Fang-Yu; Singh, Jagdish P.; SaintCyr, William
2007-01-01
A spontaneous Raman scattering optical fiber sensor is developed for a specific need of NASA/SSC for long-term detection and monitoring of the quality of liquid oxygen (LOX) in the delivery line during ground testing of rocket engines. The sensor performance was tested in the laboratory and with different excitation light sources. To evaluate the sensor performance with different excitation light sources for the LOX quality application, we have used the various mixtures of liquid oxygen and liquid nitrogen as samples. The study of the sensor performance shows that this sensor offers a great deal of flexibility and provides a cost effective solution for the application. However, an improved system response time is needed for the real-time, quantitative monitoring of the quality of cryogenic fluids in harsh environment.
NASA Astrophysics Data System (ADS)
Zhang, Zhu; Li, Hongbin; Tang, Dengping; Hu, Chen; Jiao, Yang
2017-10-01
Metering performance is the key parameter of an electronic voltage transformer (EVT), and it requires high accuracy. The conventional off-line calibration method using a standard voltage transformer is not suitable for the key equipment in a smart substation, which needs on-line monitoring. In this article, we propose a method for monitoring the metering performance of an EVT on-line based on cyber-physics correlation analysis. By the electrical and physical properties of a substation running in three-phase symmetry, the principal component analysis method is used to separate the metering deviation caused by the primary fluctuation and the EVT anomaly. The characteristic statistics of the measured data during operation are extracted, and the metering performance of the EVT is evaluated by analyzing the change in statistics. The experimental results show that the method successfully monitors the metering deviation of a Class 0.2 EVT accurately. The method demonstrates the accurate evaluation of on-line monitoring of the metering performance on an EVT without a standard voltage transformer.
Membrane inlet mass spectrometry of volatile organohalogen compounds in drinking water.
Bocchini, P; Pozzi, R; Andalò, C; Galletti, G C
1999-01-01
The analysis of organic pollutants in drinking water is a topic of wide interest, reflecting on public health and life quality. Many different methodologies have been developed and are currently employed in this context, but they often require a time-consuming sample pre-treatment. This step affects the recovery of the highly volatile compounds. Trace analysis of volatile organic pollutants in water can be performed 'on-line' by membrane inlet mass spectrometry (MIMS). In MIMS, the sample is separated from the vacuum of the mass spectrometer by a thin polymeric hollow-fibre membrane. Gases and organic volatile compounds diffuse and concentrate from the sample into the hollow-fibre membrane, and from there into the mass spectrometer. The main advantages of the technique are that no pre-treatment of samples before analysis is needed and that it has fast response times and on-line monitoring capabilities. This paper reports the set-up of the analytical conditions for the analysis of volatile organohalogen compounds (chloroform, bromoform, bromodichloromethane, chlorodibromomethane, tetrachloroethylene, trichloroethylene, 1,1,1-trichloroethane, and carbon tetrachloride). Linearity of response, repeatability, detection limits, and spectra quality are evaluated. Copyright 1999 John Wiley & Sons, Ltd.
Direct Monitoring of Trace Atmospheric Species via Ion Trap Mass Spectrometry
NASA Technical Reports Server (NTRS)
Palmer, P. T.; Pearson, Richard; Saimonson, Jay D.; Wong, Carla M.; Lawless, James G. (Technical Monitor)
1994-01-01
There is an ever-increasing emphasis on the part of government agencies, academia, and industry on enhancing our understanding of atmospheric processes and assessing the impact of human activities on these processes. While issues such as the ozone hole and rising levels of greenhouse gases have received major attention. relatively little is known about the types, concentrations, sources, and sinks of hydrocarbons in the troposphere and stratosphere. Such information would be of tremendous utility in assessing the roles of various anthropogenic and biogenic processes on global carbon cycles. An ion trap mass spectrometer has been developed for monitoring trace levels of hydrocarbons in the atmosphere on NASA's DC-8 "flying laboratory". This aircraft is used to provide measurements in support of a number of "Mission to Planet Earth" activities and tropospheric chemistry experiments. In past missions, specific compounds have been monitored via highly specialized instrumentation, fast GO, or collection of whole air samples for subsequent ground-based analysis. The ion trap has several features. including small size. excellent sensitivity, and broad applicability, which make it highly atttrat:ive for atmospheric monitoring. The design of this instrument, its air sampling interface. and the various complications associated with aircraft-deployment will be described. Data showing the sensitivity of the instrument for detecting hydrocarbons at mixing ratios below one part-per-billion, and the use of MS/MS for direct, on-line, real-time monitoring will be presented.
NASA Astrophysics Data System (ADS)
Harvey, Adam; Georganopoulos, Markos; Meyer, Eileen
2018-01-01
We present here a method for constraining the emission location of γ-rays in powerful, lined blazars (i.e., flat spectrum radio quasars (FSRQs)). We develop a diagnostic criteria, which we term the seed factor, to differentiate between γ-ray emission due to external Compton (EC) scattering in the broad line region (BLR) and the molecular torus (MT). The seed factor is determined entirely by four observable quantities; the synchrotron and inverse Compton (IC) peak frequencies, and the respective peak luminosities. It may thus be possible to use the seed factor to constrain the emission location in a model-independent way.We also present preliminary results of our analysis regarding the seed factor in quasi-simultaneous multi-wavelength SEDs from the Fermi LAT Bright AGN Sample (LBAS), historical data from the ASDC SED Builder of FSRQs in the the Monitoring Of Jets in Active galactic nuclei with VLBA Experiments (MOJAVE) sample, and quasi-simultaneous multi-wavelength SEDs from the Dynamic SEDs of southern blazars (DSSB) sample.
Jiang, Tao; Li, Xuefei; Wang, Jianfei; Su, Chunxia; Han, Wenbo; Zhao, Chao; Wu, Fengying; Gao, Guanghui; Li, Wei; Chen, Xiaoxia; Li, Jiayu; Zhou, Fei; Zhao, Jing; Cai, Weijing; Zhang, Henghui; Du, Bo; Zhang, Jun; Ren, Shengxiang; Zhou, Caicun; Yu, Hui; Hirsch, Fred R.
2017-01-01
Rationale To investigate whether the mutational landscape of circulating cell-free DNA (cfDNA) could predict and dynamically monitor the response to first-line platinum-based chemotherapy in patients with advanced non-small-cell lung cancer (NSCLC). Methods Eligible patients were included and blood samples were collected from a phase III trial. Both cfDNA fragments and fragmented genomic DNA were extracted for enrichment in a 1.15M size panel covering exon regions of 1,086 genes. Molecular mutational burden (MMB) was calculated to investigate the relationship between molecular features of cfDNA and response to chemotherapy. Results In total, 52 eligible cases were enrolled and their blood samples were prospectively collected at baseline, every cycle of chemotherapy and time of disease progression. At baseline, alterations of 17 genes were found. Patients with partial response (PR) had significantly lower baseline MMB of these genes than those patients with either stable disease (SD) (P = 0.0006) or progression disease (PD) (P = 0.0074). Further analysis revealed that the mutational landscape of cfDNA from pretreatment blood samples were distinctly different among patients with PR vs. SD/PD. For patients with baseline TP53 mutation, those with PR experienced a significant reduction in MMB whereas patients with SD or PD experienced an increase after two, three or four cycles of chemotherapy. Furthermore, patients with low MMB had superior response rate and significantly longer progression-free survival than those with high MMB. Conclusion This study indicated that the mutational landscape of cfDNA has potential clinical value to predict the therapeutic response to first-line platinum-based doublet chemotherapy in NSCLC patients. At the single gene level, dynamic change of molecular mutational burden of TP53 is valuable to monitor efficacy (and, therefore, might aid in early recognition of resistance and relapse) in patients harboring this mutation at baseline. PMID:29187901
US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, D.F.; Rope, R.C.; Mondecar, M.
1993-04-01
Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less
System and method for monitoring water content or other dielectric influences in a medium
Cherry, Robert S.; Anderson, Allen A.
2001-01-01
A sensor system is provided that measures water content or other detectable properties in a medium along the entire length of the sensor at any point in time. The sensor system includes an electromagnetic signal generator and a transmission line disposed in a medium to be monitored. Alternatively, the transmission line can be configured for movement across a medium to be monitored, or the transmission line can be fixed relative to a moving medium being monitored. A signal is transmitted along the transmission line at predetermined frequencies, and the signal is returned back along the transmission line and/or into an optional receive line in proximity to the transmission line. The returned signal is processed to generate a one-dimensional data output profile that is a function of a detectable property of the medium. The data output profile can be mapped onto a physical system to generate a two-dimensional or three-dimensional profile if desired. The sensor system is useful in a variety of different applications such as agriculture, horticulture, biofiltration systems for industrial offgases, leak detection in landfills or drum storage facilities at buried waste sites, and in many other applications.
NASA Astrophysics Data System (ADS)
Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.
2017-12-01
The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.
Guo, Pengqi; Xu, Xinya; Xian, Liang; Ge, Yanhui; Luo, Zhimin; Du, Wei; Jing, Wanghui; Zeng, Aiguo; Chang, Chun; Fu, Qiang
2016-12-01
Nowadays, the illegal use of estradiol in cosmetics has caused a series of events which endangering public health seriously. Therefore, it is imperative to establish a simple, fast and specific method for monitoring the illegal use of estradiol in cosmetics. In current study, we developed a molecular imprinted monolithic column two dimensional liquid chromatography method (MIMC-2D-LC) for rapid and selective determination of estradiol in various cosmetic samples. The best polymerization, morphology, structure property, surface groups, and the adsorption performance of the prepared material were investigated. The MIMC-2D-LC was validated and successfully used for detecting estradiol in cosmetic samples with good selectivity, sensitivity, efficiency and reproducibility. The linear range of the MIMC-2D-LC for estradiol was 0.5-50μgg -1 with the limit of detection of 0.08μgg -1 . Finally, six batches of cosmetic samples obtained from local markets were tested by the proposed method. The test results showed that the illegal use of estradiol still existed in the commercially available samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Monitoring method and apparatus using high-frequency carrier
Haynes, Howard D.
1996-01-01
A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device.
Off-line and real-time monitoring of acetaminophen photodegradation by an electrochemical sensor.
Berto, Silvia; Carena, Luca; Chiavazza, Enrico; Marletti, Matteo; Fin, Andrea; Giacomino, Agnese; Malandrino, Mery; Barolo, Claudia; Prenesti, Enrico; Vione, Davide
2018-08-01
The photochemistry of N-acetyl-para-aminophenol (acetaminophen, APAP) is here investigated by using differential pulse voltammetry (DPV) analysis to monitor APAP photodegradation upon steady-state irradiation. The purpose of this work is to assess the applicability of DPV to monitor the photochemical behaviour of xenobiotics, along with the development of an electrochemical set-up for the real-time monitoring of APAP photodegradation. We here investigated the APAP photoreactivity towards the main photogenerated reactive transients species occurring in sunlit surface waters (hydroxyl radical HO, carbonate radical CO 3 - , excited triplet state of anthraquinone-2-sulfonate used as proxy of the chromophoric DOM, and singlet oxygen 1 O 2 ), and determined relevant kinetic parameters. A standard procedure based on UV detection coupled with liquid chromatography (HPLC-UV) was used under identical experimental conditions to compare and verify the DPV-based results. The latter were in agreement with HPLC data, with the exception of the triplet-sensitized processes. In the other cases, DPV could be used as an alternative to the well-tested but more costly and time-consuming HPLC-UV technique. We have also assessed the reaction rate constant between APAP and HO by real-time DPV, which allowed for the monitoring of APAP photodegradation inside the irradiation chamber. Unfortunately, real-time DPV measurements are likely to be affected by temperature variations of the irradiated samples. Overall, DPV appeared as a fast, cheap and reasonably reliable technique when used for the off-line monitoring of APAP photodegradation. When a suitable real-time procedure is developed, it could become a very straightforward method to study the photochemical behaviour of electroactive xenobiotics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sarraguça, Mafalda C; Paulo, Ana; Alves, Madalena M; Dias, Ana M A; Lopes, João A; Ferreira, Eugénio C
2009-10-01
The performance of an activated sludge reactor can be significantly enhanced through use of continuous and real-time process-state monitoring, which avoids the need to sample for off-line analysis and to use chemicals. Despite the complexity associated with wastewater treatment systems, spectroscopic methods coupled with chemometric tools have been shown to be powerful tools for bioprocess monitoring and control. Once implemented and optimized, these methods are fast, nondestructive, user friendly, and most importantly, they can be implemented in situ, permitting rapid inference of the process state at any moment. In this work, UV-visible and NIR spectroscopy were used to monitor an activated sludge reactor using in situ immersion probes connected to the respective analyzers by optical fibers. During the monitoring period, disturbances to the biological system were induced to test the ability of each spectroscopic method to detect the changes in the system. Calibration models based on partial least squares (PLS) regression were developed for three key process parameters, namely chemical oxygen demand (COD), nitrate concentration (N-NO(3)(-)), and total suspended solids (TSS). For NIR, the best results were achieved for TSS, with a relative error of 14.1% and a correlation coefficient of 0.91. The UV-visible technique gave similar results for the three parameters: an error of approximately 25% and correlation coefficients of approximately 0.82 for COD and TSS and 0.87 for N-NO(3)(-) . The results obtained demonstrate that both techniques are suitable for consideration as alternative methods for monitoring and controlling wastewater treatment processes, presenting clear advantages when compared with the reference methods for wastewater treatment process qualification.
Development of GUI Type On-Line Condition Monitoring Program for a Turboprop Engine Using Labview
NASA Astrophysics Data System (ADS)
Kong, Changduk; Kim, Keonwoo
2011-12-01
Recently, an aero gas turbine health monitoring system has been developed for precaution and maintenance action against faults or performance degradations of the advanced propulsion system which occurs in severe environments such as high altitude, foreign object damage particles, hot and heavy rain and snowy atmospheric conditions. However to establish this health monitoring system, the online condition monitoring program is firstly required, and the program must monitor the engine performance trend through comparison between measured engine performance data and base performance results calculated by base engine performance model. This work aims to develop a GUI type on-line condition monitoring program for the PT6A-67 turboprop engine of a high altitude and long endurance operation UAV using LabVIEW. The base engine performance of the on-line condition monitoring program is simulated using component maps inversely generated from the limited performance deck data provided by engine manufacturer. The base engine performance simulation program is evaluated because analysis results by this program agree well with the performance deck data. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between clean engine performance results calculated by the base performance simulation program and measured engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed online monitoring system. For user friendly purpose, all monitoring program are coded by LabVIEW, and monitoring examples are demonstrated using the proposed GUI type on-condition monitoring program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solis, R.P.; Chavez, F.C.; Garcia, S.E.
1997-12-31
In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed throughmore » a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.« less
Ozone measurement system for NASA global air sampling program
NASA Technical Reports Server (NTRS)
Tiefermann, M. W.
1979-01-01
The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.
Verplaetse, Ruth; Henion, Jack
2016-01-01
Opioids are well known, widely used painkillers. Increased stability of opioids in the dried blood spot (DBS) matrix compared to blood/plasma has been described. Other benefits provided by DBS techniques include point-of-care collection, less invasive micro sampling, more economical shipment, and convenient storage. Current methodology for analysis of micro whole blood samples for opioids is limited to the classical DBS workflow, including tedious manual punching of the DBS cards followed by extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. The goal of this study was to develop and validate a fully automated on-line sample preparation procedure for the analysis of DBS micro samples relevant to the detection of opioids in finger prick blood. To this end, automated flow-through elution of DBS cards was followed by on-line solid-phase extraction (SPE) and analysis by LC-MS/MS. Selective, sensitive, accurate, and reproducible quantitation of five representative opioids in human blood at sub-therapeutic, therapeutic, and toxic levels was achieved. The range of reliable response (R(2) ≥0.997) was 1 to 500 ng/mL whole blood for morphine, codeine, oxycodone, hydrocodone; and 0.1 to 50 ng/mL for fentanyl. Inter-day, intra-day, and matrix inter-lot accuracy and precision was less than 15% (even at lower limits of quantitation (LLOQ) level). The method was successfully used to measure hydrocodone and its major metabolite norhydrocodone in incurred human samples. Our data support the enormous potential of DBS sampling and automated analysis for monitoring opioids as well as other pharmaceuticals in both anti-doping and pain management regimens. Copyright © 2015 John Wiley & Sons, Ltd.
Lambertus, Gordon; Shi, Zhenqi; Forbes, Robert; Kramer, Timothy T; Doherty, Steven; Hermiller, James; Scully, Norma; Wong, Sze Wing; LaPack, Mark
2014-01-01
An on-line analytical method based on transmission near-infrared spectroscopy (NIRS) for the quantitative determination of water concentrations (in parts per million) was developed and applied to the manufacture of a pharmaceutical intermediate. Calibration models for water analysis, built at the development site and applied at the manufacturing site, were successfully demonstrated during six manufacturing runs at a 250-gallon scale. The water measurements will be used as a forward-processing control point following distillation of a toluene product solution prior to use in a Grignard reaction. The most significant impact of using this NIRS-based process analytical technology (PAT) to replace off-line measurements is the significant reduction in the risk of operator exposure through the elimination of sampling of a severely lachrymatory and mutagenic compound. The work described in this report illustrates the development effort from proof-of-concept phase to manufacturing implementation.
Ding, Shujing; Dudley, Ed; Chen, Lijuan; Plummer, Sue; Tang, Jiandong; Newton, Russell P; Brenton, A Gareth
2006-01-01
Ginkgo biloba is one of the most popular herbal nutritional supplements, with terpene lactones and flavonoids being the two major active components. An on-line purification high-performance liquid chromatography/mass spectrometry (HPLC/MS) method was successfully developed for the quantitative determination of flavonoids and terpene lactones excreted in human urine after ingesting the herbal supplement. Satisfactory separation was obtained using a C18 capillary column made in-house with sample clean-up and pre-concentration achieved using a C18 pre-column with column switching. High selectivity and limits of detection of 1-18 ng/mL were achieved using a selected ion monitoring (SIM) scan in negative ion mode; the on-line solid-phase extraction (SPE) recovery of the active components in Ginkgo biloba determined in this study was greater than 75%. Copyright 2006 John Wiley & Sons, Ltd.
1988-11-01
revri if necenary and iIenitif by block number) FIELO GROUP SUS-GROUP Installation Restoration Program , Groundwater ,P& Soils. Surface water ...qoulkhave been affected by the Site 3 flight line storm drainage outfall. Groundwater quali y samples were collected from the Site 4 water supply well No...monitoring. o Groundwater from the Site 4 water well No. 10 contains no VOCs. Because it remains unclear whether levels of THMs previously measured
Hsieh, Yi-Da; Nakamura, Shota; Abdelsalam, Dahi Ghareab; Minamikawa, Takeo; Mizutani, Yasuhiro; Yamamoto, Hirotsugu; Iwata, Tetsuo; Hindle, Francis; Yasui, Takeshi
2016-01-01
Terahertz (THz) spectroscopy is a promising method for analysing polar gas molecules mixed with unwanted aerosols due to its ability to obtain spectral fingerprints of rotational transition and immunity to aerosol scattering. In this article, dynamic THz spectroscopy of acetonitrile (CH3CN) gas was performed in the presence of smoke under the atmospheric pressure using a fibre-based, asynchronous-optical-sampling THz time-domain spectrometer. To match THz spectral signatures of gas molecules at atmospheric pressure, the spectral resolution was optimized to 1 GHz with a measurement rate of 1 Hz. The spectral overlapping of closely packed absorption lines significantly boosted the detection limit to 200 ppm when considering all the spectral contributions of the numerous absorption lines from 0.2 THz to 1 THz. Temporal changes of the CH3CN gas concentration were monitored under the smoky condition at the atmospheric pressure during volatilization of CH3CN droplets and the following diffusion of the volatilized CH3CN gas without the influence of scattering or absorption by the smoke. This system will be a powerful tool for real-time monitoring of target gases in practical applications of gas analysis in the atmospheric pressure, such as combustion processes or fire accident. PMID:27301319
Brouckaert, Davinia; De Meyer, Laurens; Vanbillemont, Brecht; Van Bockstal, Pieter-Jan; Lammens, Joris; Mortier, Séverine; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas
2018-04-03
Near-infrared chemical imaging (NIR-CI) is an emerging tool for process monitoring because it combines the chemical selectivity of vibrational spectroscopy with spatial information. Whereas traditional near-infrared spectroscopy is an attractive technique for water content determination and solid-state investigation of lyophilized products, chemical imaging opens up possibilities for assessing the homogeneity of these critical quality attributes (CQAs) throughout the entire product. In this contribution, we aim to evaluate NIR-CI as a process analytical technology (PAT) tool for at-line inspection of continuously freeze-dried pharmaceutical unit doses based on spin freezing. The chemical images of freeze-dried mannitol samples were resolved via multivariate curve resolution, allowing us to visualize the distribution of mannitol solid forms throughout the entire cake. Second, a mannitol-sucrose formulation was lyophilized with variable drying times for inducing changes in water content. Analyzing the corresponding chemical images via principal component analysis, vial-to-vial variations as well as within-vial inhomogeneity in water content could be detected. Furthermore, a partial least-squares regression model was constructed for quantifying the water content in each pixel of the chemical images. It was hence concluded that NIR-CI is inherently a most promising PAT tool for continuously monitoring freeze-dried samples. Although some practicalities are still to be solved, this analytical technique could be applied in-line for CQA evaluation and for detecting the drying end point.
NASA Astrophysics Data System (ADS)
Hsieh, Yi-Da; Nakamura, Shota; Abdelsalam, Dahi Ghareab; Minamikawa, Takeo; Mizutani, Yasuhiro; Yamamoto, Hirotsugu; Iwata, Tetsuo; Hindle, Francis; Yasui, Takeshi
2016-06-01
Terahertz (THz) spectroscopy is a promising method for analysing polar gas molecules mixed with unwanted aerosols due to its ability to obtain spectral fingerprints of rotational transition and immunity to aerosol scattering. In this article, dynamic THz spectroscopy of acetonitrile (CH3CN) gas was performed in the presence of smoke under the atmospheric pressure using a fibre-based, asynchronous-optical-sampling THz time-domain spectrometer. To match THz spectral signatures of gas molecules at atmospheric pressure, the spectral resolution was optimized to 1 GHz with a measurement rate of 1 Hz. The spectral overlapping of closely packed absorption lines significantly boosted the detection limit to 200 ppm when considering all the spectral contributions of the numerous absorption lines from 0.2 THz to 1 THz. Temporal changes of the CH3CN gas concentration were monitored under the smoky condition at the atmospheric pressure during volatilization of CH3CN droplets and the following diffusion of the volatilized CH3CN gas without the influence of scattering or absorption by the smoke. This system will be a powerful tool for real-time monitoring of target gases in practical applications of gas analysis in the atmospheric pressure, such as combustion processes or fire accident.
Zachariah, Philip; Furuya, E. Yoko; Edwards, Jeffrey; Dick, Andrew; Liu, Hangsheng; Herzig, Carolyn; Pogorzelska-Maziarz, Monika; Stone, Patricia W.; Saiman, Lisa
2014-01-01
Background Bundles and checklists have been shown to decrease CLABSIs, but implementation of these practices and association with CLABSI rates have not been described nationally. We describe implementation and levels of compliance with prevention practices in a sample of US Neonatal ICUs and assess their association with CLABSI rates. Methods An online survey assessing infection prevention practices was sent to hospitals participating in National Healthcare Safety Network CLABSI surveillance in October 2011. Participating hospitals permitted access to their NICU CLABSI rates. Multivariable regressions were used to test the association between compliance with NICU specific CLABSI prevention practices and corresponding CLABSI rates. Results Overall, 190 Level II/III and Level III NICUs participated. The majority of NICUs had written policies (84%-93%) and monitored compliance with bundles and checklists (88% - 91%). Reporting ≥ 95% compliance for any of the practices ranged from 50%- 63%. Reporting ≥ 95% compliance with insertion checklist and assessment of daily line necessity were significantly associated with lower CLABSI rates (p<0.05). Conclusions Most NICUs in this national sample have instituted CLABSI prevention policies and monitor compliance, although reporting compliance ≥ 95% was suboptimal. Reporting ≥ 95% compliance with select CLABSI prevention practices was associated with lower CLABSI rates. Further studies should focus on identifying and improving compliance with effective CLABSI prevention practices in neonates. PMID:25087136
Hsieh, Yi-Da; Nakamura, Shota; Abdelsalam, Dahi Ghareab; Minamikawa, Takeo; Mizutani, Yasuhiro; Yamamoto, Hirotsugu; Iwata, Tetsuo; Hindle, Francis; Yasui, Takeshi
2016-06-15
Terahertz (THz) spectroscopy is a promising method for analysing polar gas molecules mixed with unwanted aerosols due to its ability to obtain spectral fingerprints of rotational transition and immunity to aerosol scattering. In this article, dynamic THz spectroscopy of acetonitrile (CH3CN) gas was performed in the presence of smoke under the atmospheric pressure using a fibre-based, asynchronous-optical-sampling THz time-domain spectrometer. To match THz spectral signatures of gas molecules at atmospheric pressure, the spectral resolution was optimized to 1 GHz with a measurement rate of 1 Hz. The spectral overlapping of closely packed absorption lines significantly boosted the detection limit to 200 ppm when considering all the spectral contributions of the numerous absorption lines from 0.2 THz to 1 THz. Temporal changes of the CH3CN gas concentration were monitored under the smoky condition at the atmospheric pressure during volatilization of CH3CN droplets and the following diffusion of the volatilized CH3CN gas without the influence of scattering or absorption by the smoke. This system will be a powerful tool for real-time monitoring of target gases in practical applications of gas analysis in the atmospheric pressure, such as combustion processes or fire accident.
SPECTRAL OPTICAL MONITORING OF THE NARROW-LINE SEYFERT 1 GALAXY Ark 564
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shapovalova, A. I.; Burenkov, A. N.; Popovic, L. C.
2012-09-15
We present the results of a long-term (1999-2010) spectral optical monitoring campaign of the active galactic nucleus (AGN) Ark 564, which shows a strong Fe II line emission in the optical. This AGN is a narrow-line Seyfert 1 (NLS1) galaxy, a group of AGNs with specific spectral characteristics. We analyze the light curves of the permitted H{alpha}, H{beta}, optical Fe II line fluxes, and the continuum flux in order to search for a time lag between them. Additionally, in order to estimate the contribution of iron lines from different multiplets, we fit the H{beta} and Fe II lines with amore » sum of Gaussian components. We find that during the monitoring period the spectral variation (F{sub max}/F{sub min}) of Ark 564 is between 1.5 for H{alpha} and 1.8 for the Fe II lines. The correlation between the Fe II and H{beta} flux variations is of higher significance than that of H{alpha} and H{beta} (whose correlation is almost absent). The permitted-line profiles are Lorentzian-like and do not change shape during the monitoring period. We investigate, in detail, the optical Fe II emission and find different degrees of correlation between the Fe II emission arising from different spectral multiplets and the continuum flux. The relatively weak and different degrees of correlations between permitted lines and continuum fluxes indicate a rather complex source of ionization of the broad-line emission region.« less
Rowland-Jones, Ruth C; van den Berg, Frans; Racher, Andrew J; Martin, Elaine B; Jaques, Colin
2017-03-01
Cell culture process development requires the screening of large numbers of cell lines and process conditions. The development of miniature bioreactor systems has increased the throughput of such studies; however, there are limitations with their use. One important constraint is the limited number of offline samples that can be taken compared to those taken for monitoring cultures in large-scale bioreactors. The small volume of miniature bioreactor cultures (15 mL) is incompatible with the large sample volume (600 µL) required for bioanalysers routinely used. Spectroscopy technologies may be used to resolve this limitation. The purpose of this study was to compare the use of NIR, Raman, and 2D-fluorescence to measure multiple analytes simultaneously in volumes suitable for daily monitoring of a miniature bioreactor system. A novel design-of-experiment approach is described that utilizes previously analyzed cell culture supernatant to assess metabolite concentrations under various conditions while providing optimal coverage of the desired design space. Multivariate data analysis techniques were used to develop predictive models. Model performance was compared to determine which technology is more suitable for this application. 2D-fluorescence could more accurately measure ammonium concentration (RMSE CV 0.031 g L -1 ) than Raman and NIR. Raman spectroscopy, however, was more robust at measuring lactate and glucose concentrations (RMSE CV 1.11 and 0.92 g L -1 , respectively) than the other two techniques. The findings suggest that Raman spectroscopy is more suited for this application than NIR and 2D-fluorescence. The implementation of Raman spectroscopy increases at-line measuring capabilities, enabling daily monitoring of key cell culture components within miniature bioreactor cultures. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:337-346, 2017. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.
NASA Astrophysics Data System (ADS)
Lim, Sungsoo; Lee, Seohyung; Kim, Jun-geon; Lee, Daeho
2018-01-01
The around-view monitoring (AVM) system is one of the major applications of advanced driver assistance systems and intelligent transportation systems. We propose an on-line calibration method, which can compensate misalignments for AVM systems. Most AVM systems use fisheye undistortion, inverse perspective transformation, and geometrical registration methods. To perform these procedures, the parameters for each process must be known; the procedure by which the parameters are estimated is referred to as the initial calibration. However, when only using the initial calibration data, we cannot compensate misalignments, caused by changing equilibria of cars. Moreover, even small changes such as tire pressure levels, passenger weight, or road conditions can affect a car's equilibrium. Therefore, to compensate for this misalignment, additional techniques are necessary, specifically an on-line calibration method. On-line calibration can recalculate homographies, which can correct any degree of misalignment using the unique features of ordinary parking lanes. To extract features from the parking lanes, this method uses corner detection and a pattern matching algorithm. From the extracted features, homographies are estimated using random sample consensus and parameter estimation. Finally, the misaligned epipolar geographies are compensated via the estimated homographies. Thus, the proposed method can render image planes parallel to the ground. This method does not require any designated patterns and can be used whenever cars are placed in a parking lot. The experimental results show the robustness and efficiency of the method.
Noguchi, Takako; Ikeda, Masaaki; Ohmiya, Yoshihiro; Nakajima, Yoshihiro
2008-01-01
Background Luciferase assay systems enable the real-time monitoring of gene expression in living cells. We have developed a dual-color luciferase assay system in which the expression of multiple genes can be tracked simultaneously using green- and red-emitting beetle luciferases. We have applied the system to monitoring independent gene expressions in two types of cocultured fibroblasts in real time. Results Two Rat-1 cell lines were established that stably express either green- or red-emitting luciferases under the control of the mBmal1 promoter, a canonical clock gene. We cocultured these cell lines, and gene expression profiles in both were monitored simultaneously. The circadian rhythms of these cell lines are independent, oscillating following their intrinsic circadian phases, even when cocultured. Furthermore, the independent rhythms were synchronized by medium change as an external stimulus. Conclusion Using this system, we successfully monitored independent gene expression patterns in two lines of cocultured fibroblasts. PMID:18416852
A circumpolar monitoring framework for polar bears
Vongraven, Dag; Aars, Jon; Amstrup, Steven C.; Atkinson, Stephen N.; Belikov, Stanislav; Born, Erik W.; DeBruyn, T.D.; Derocher, Andrew E.; Durner, George M.; Gill, Michael J.; Lunn, Nicholas J.; Obbard, Martyn E.; Omelak, Jack; Ovsyanikov, Nikita; Peacock, Elizabeth; Richardson, E.E.; Sahanatien, Vicki; Stirling, Ian; Wiig, Øystein
2012-01-01
Polar bears (Ursus maritimus) occupy remote regions that are characterized by harsh weather and limited access. Polar bear populations can only persist where temporal and spatial availability of sea ice provides adequate access to their marine mammal prey. Observed declines in sea ice availability will continue as long as greenhouse gas concentrations rise. At the same time, human intrusion and pollution levels in the Arctic are expected to increase. A circumpolar understanding of the cumulative impacts of current and future stressors is lacking, long-term trends are known from only a few subpopulations, and there is no globally coordinated effort to monitor effects of stressors. Here, we describe a framework for an integrated circumpolar monitoring plan to detect ongoing patterns, predict future trends, and identify the most vulnerable polar bear subpopulations. We recommend strategies for monitoring subpopulation abundance and trends, reproduction, survival, ecosystem change, human-caused mortality, human–bear conflict, prey availability, health, stature, distribution, behavioral change, and the effects that monitoring itself may have on polar bears. We assign monitoring intensity for each subpopulation through adaptive assessment of the quality of existing baseline data and research accessibility. A global perspective is achieved by recommending high intensity monitoring for at least one subpopulation in each of four major polar bear ecoregions. Collection of data on harvest, where it occurs, and remote sensing of habitat, should occur with the same intensity for all subpopulations. We outline how local traditional knowledge may most effectively be combined with the best scientific methods to provide comparable and complementary lines of evidence. We also outline how previously collected intensive monitoring data may be sub-sampled to guide future sampling frequencies and develop indirect estimates or indices of subpopulation status. Adoption of this framework will inform management and policy responses to changing worldwide polar bear status and trends.
Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia
2015-01-01
The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs.
Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia
2015-01-01
Background The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. Methods We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Results Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Conclusion Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs. PMID:25793531
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christien, F., E-mail: frederic.christien@univ-nantes.fr; Le Gall, R.; Telling, M. T. F.
2015-05-15
A method is proposed for the monitoring of metal recrystallization using neutron diffraction that is based on the measurement of stored energy. Experiments were performed using deformed metal specimens heated in-situ while mounted at the sample position of the High Resolution Powder Diffractometer, HRPD (ISIS Facility), UK. Monitoring the breadth of the resulting Bragg lines during heating not only allows the time-dependence (or temperature-dependence) of the stored energy to be determined but also the recrystallized fraction. The analysis method presented here was developed using pure nickel (Ni270) specimens with different deformation levels from 0.29 to 0.94. In situ temperature rampingmore » as well as isothermal annealing was undertaken. The method developed in this work allows accurate and quantitative monitoring of the recrystallization process. The results from neutron diffraction are satisfactorily compared to data obtained from calorimetry and hardness measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busack, Craig A.; Fritts, Anthony L.; Loxterman, Janet
2003-05-01
In chapter 1 we report on studies of the population genetic structure, using DNA microsatellites, of steelhead collected from different locations in the Yakima River basin (Roza Dam, Ahtanum Creek, Toppenish Creek, and Satus Creek) in 2000 and 2001. Of 28 pairwise tests of genotypic differentiation, only the 2000 and 2001 Roza Dam collections and the 2000 and 2001 Satus Creek collections did not exhibit significant differences. Similarly, pairwise tests of genetic differentiation (FST) were significant for all comparisons except the between-years comparisons of Roza Dam, Toppenish Creek, and Satus Creek collections. All tests between populations sampled from different localitiesmore » were significant, indicating that these collections represent genetically differentiated stocks. In chapter 2 we report on genetic comparisons, again using microsatellites, of the three spring chinook populations in the Yakima basin (Upper Yakima, Naches, and American) with respect to our ability to be able to estimate the proportions of the three populations in mixed smolt samples collected at Chandler. We evaluated this both in terms of mixed fishery analysis, where proportions are estimated, but the likely provenance of any particular fish is unknown, and classification, where an attempt is made to assign individual fish to their population of origin. Simulations were done over the entire ranged of stock proportions observed in the Yakima basin in the last 20+ years. Stock proportions can be estimated very accurately by either method. Chapter 3 reports on our ongoing effort at cryopreserving semen from wild Upper Yakima spring chinook. In 2002, semen from 91 males, more than 50% of those spawned, was cryopreserved. Representation over the spawning season was excellent. Chapters 4,5, and 6 all relate to the continuing development of the domestication study design. Chapter 4 details the ISRP consultations and evolution of the design from last year's preferred alternative to the current plan of using the Naches population as a wild control, and maintaining a hatchery-only control line alongside the supplemented line. During discussions this year a major issue was the possible impact to the research and to the supplementation effort, of gene flow from precocious males from the hatchery control line into the supplemented line. At the end of the contracting period, this issue still had not been resolved. Along with the discussion of development of the domestication research design, chapter 4 presents the current monitoring plan document, with discussion of the approach to the various traits to be analyzed. Chapters 5 and 6 deal with experimental power of the domestication monitoring design. There is still much work to be done on power, but in chapter 5 we explore our power to detect differences among the three lines for traits measured on individual adults. Power was found to be quite good for effects of 5% per generation over three generations for traits having a coefficient of variation (CV) of 10-20%, but low if the CV was 50%. Power is higher for comparisons between the hatchery control line and supplemented line than between the supplemented line and the wild control, a consequence of trying to avoid heavy impacts to the Naches population. Power could be improved considerably improved by sampling more Naches fish in years of high abundance. Chapter 6 presents the same power analysis, but attempts to explore the effect of precocious males from the hatchery control line spawning in the wild. It is clear that if gene flow from precocious males is more than one or two percent that the between line comparisons will be biased, making the supplemented line appear to be more similar to the hatchery control line than it should and more different from the wild control line than it should. However, it was also clear that more analysis is desirable, as the heightened or diminished power is really just an enhancement or reduction of a real difference. A more straightforward analysis of the proportion of observed differences that can be attributed to precocious gene flow needs to be done.« less
Bell, C.F.; Belval, D.L.; Campbell, J.P.
1996-01-01
Water-quality samples were collected at the Fall Line of five tributaries to the Chesapeake Bay in Virginia during a 6- to 7-year period. The water-quality data were used to estimate loads of nutrients and suspended solids from these tributaries to the non-tidal part of Chesapeake Bay Basin and to identify trends in water quality. Knowledge of trends in water quality is required to assess the effectiveness of nutrient manage- ment strategies in the five basins. Multivariate log-linear regression and the seasonal Kendall test were used to estimate flow-adjusted trends in constituent concentration and load. Results of multivariate log-linear regression indicated a greater number of statistically significant trends than the seasonal Kendall test; how-ever, when both methods indicated a significant trend, both agreed on the direction of the trend. Interpre- tation of the trend estimates for this report was based on results of the parametric regression method. No significant trends in total nitrogen concentration were detected at the James River monitoring station from July 1988 through June 1995, though total Kjeldahl nitrogen concen- tration decreased slightly in base-flow samples. Total phosphorus concentration decreased about 29 percent at this station during the sampling period. Most of the decrease can be attributed to reductions in point-source phosphorus loads in 1988 and 1989, especially the phosphate detergent ban of 1988. No significant trends in total suspended solids were observed at the James River monitoring station, and no trends in runoff- derived constituents were interpreted for this river. Significant decreases were detected in concentrations of total nitrogen, total Kjeldahl nitrogen, dissolved nitrite-plus-nitrate nitrogen, and total suspended solids at the Rappahannock River monitoring station between July 1988 and June 1995. A similar downward trend in total phosphorus concentration was significant at the 90-percent confidence level, but not the 95-percent confidence level. These decreases can be attributed primarily to reductions in nonpoint nutrient and sediment loads, and may have been partially caused by implementation of best management practices on agricultural and silvicultural land. Flow-adjusted trends observed at the Appomattox, Pamunkey, and Mattaponi monitoring stations were more difficult to explain than those at the James and Rappahannock stations. Total Kjeldahl nitrogen and total phosphorus increased 16 and 23 percent, respectively, at the Appomattox River monitoring station from July 1989 through June 1995. Total phosphorus concentration increased about 46 percent at the Pamunkey River monitoring station between July 1989 and June 1995. At the Mattaponi River monitoring station, decreases in dissolved nitrite-plus-nitrate nitrogen were offset by increases in total Kjeldahl nitrogen, resulting in no net change in total nitrogen concentration from October 1989 through June 1995.
Meloni, Monica; Corti, Natascia; Müller, Daniel; Henning, Lars; Gutteck, Ursula; von Braun, Amrei; Weber, Rainer; Fehr, Jan
2015-01-01
Therapeutic target serum concentrations of first-line antituberculosis drugs have not been well defined in clinical studies in tuberculosis (TB) patients. We retrospectively investigated the estimated maximum serum concentrations (eC max) of antituberculosis drugs and clinical outcome of TB patients with therapeutic drug monitoring performed between 2010-2012 at our institution, and follow-up until March 2014. The eC max was defined as the highest serum concentration during a sampling period (2, 4 and 6 hours after drug ingestion). We compared the results with published eC max values, and categorised them as either "within reference range", "low eC max", or "very low eC max".Low/very low eC max-levels were defined as follows: isoniazid 2-3/<2 mg/l, rifampicin 4-8/<4 mg/l, rifabutin 0.2-0.3/<0.2 mg/l, ethambutol 1-2/<0.1 mg/l and pyrazinamide <20 mg/l. Concentrations of antituberculosis drugs in 175 serum samples of 17 patients with TB were analysed. In 12 (71%) patients, multiple therapeutic drug monitoring samples were collected over time, in 5 (29%) patients only one sample was available for therapeutic drug monitoring. Overall, 94% of all patients had at least one low antituberculosis drug concentration. Overall, 64% of all eC max levels were classified as "low" or "very low". The eC max was below the relevant reference range in 80% of isoniazid, 95% of rifampicin, 30% of pyrazinamide, and 30% of ethambutol measurements. All but one patient were cured of tuberculosis. Although many antituberculosis drug serum concentrations were below the widely used reference ranges, 16 of 17 patients were cured of tuberculosis. These results challenge the use of the published reference ranges for therapeutic drug monitoring.
A microfluidic in-line ELISA for measuring secreted protein under perfusion.
Luan, Qiyue; Cahoon, Stacey; Wu, Agnes; Bale, Shyam Sundhar; Yarmush, Martin; Bhushan, Abhinav
2017-11-11
Recent progress in the development of microfluidic microphysiological systems such as 'organs-on-chips' and microfabricated cell culture is geared to simulate organ-level physiology. These tissue models leverage microengineering technologies that provide capabilities of presenting cultured cells with input signals in a more physiologically relevant context such as perfused flow. Proteins that are secreted from cells have important information about the health of the cells. Techniques to quantify cellular proteins include mass spectrometry to ELISA (enzyme-linked immunosorbent assay). Although our capability to perturb the cells in the microphysiological systems with varying inputs is well established, we lack the tools to monitor in-line the cellular responses. User intervention for sample collection and off-site is cumbersome, causes delays in obtaining results, and is especially expensive because of collection, storage, and offline processing of the samples, and in many case, technically impractical to carry out because of limitated sample volumes. To address these shortcomings, we report the development of an ELISA that is carried out in-line under perfusion within a microfluidic device. Using this assay, we measured the albumin secreted from perfused hepatocytes without and under stimulation by IL-6. Since the method is based on a sandwich ELISA, we envision broad application of this technology to not just organs-on-chips but also to characterizing the temporal release and measurement of soluble factors and response to drugs.
Williams, George W; George, Christy A; Harvey, Brian C; Freeman, Jenny E
2017-01-01
Current respiratory monitoring technologies such as pulse oximetry and capnography have been insufficient to identify early signs of respiratory compromise in nonintubated patients. Pulse oximetry, when used appropriately, will alert the caregiver to an episode of dangerous hypoxemia. However, desaturation lags significantly behind hypoventilation and alarm fatigue due to false alarms poses an additional problem. Capnography, which measures end-tidal CO2 (EtCO2) and respiratory rate (RR), has not been universally used for nonintubated patients for multiple reasons, including the inability to reliably relate EtCO2 to the level of impending respiratory compromise and lack of patient compliance. Serious complications related to respiratory compromise continue to occur as evidenced by the Anesthesiology 2015 Closed Claims Report. The Anesthesia Patient Safety Foundation has stressed the need to improve monitoring modalities so that "no patient will be harmed by opioid-induced respiratory depression." A recently available, Food and Drug Administration-approved noninvasive respiratory volume monitor (RVM) can continuously and accurately monitor actual ventilation metrics: tidal volume, RR, and minute ventilation (MV). We designed this study to compare the capabilities of capnography versus the RVM to detect changes in respiratory metrics. Forty-eight volunteer subjects completed the study. RVM measurements (MV and RR) were collected simultaneously with capnography (EtCO2 and RR) using 2 sampling methods (nasal scoop cannula and snorkel mouthpiece with in-line EtCO2 sensor). For each sampling method, each subject performed 6 breathing trials at 3 different prescribed RRs (slow [5 min], normal [12.6 ± 0.6 min], and fast [25 min]). All data are presented as mean ± SEM unless otherwise indicated. Following transitions in prescribed RRs, the RVM reached a new steady state value of MV in 37.7 ± 1.4 seconds while EtCO2 changes were notably slower, often failing to reach a new asymptote before a 2.5-minute threshold. RRs as measured by RVM and capnography during steady breathing were strongly correlated (R = 0.98 ± 0.01, bias = Capnograph-based RR - RVM-based RR = 0.21 ± 1.24 [SD] min). As expected, changes in MV were negatively correlated with changes in EtCO2. However, large changes in MV following transitions in prescribed RR resulted in relatively small changes in EtCO2 (instrument sensitivity = ΔEtCO2/ΔMV = -0.71 ± 0.11 and -0.55 ± 0.11 mm Hg per 1 L/min for nasal and in-line sampling, respectively). Nasal cannula EtCO2 measurements were on average 4 mm Hg lower than in-line measurements. RVM measurements of MV change more rapidly and by a greater degree than capnography in response to respiratory changes in nonintubated patients. Earlier detection could enable earlier intervention that could potentially reduce frequency and severity of complications due to respiratory depression.
Monitoring transients in low inductance circuits
Guilford, R.P.; Rosborough, J.R.
1985-10-21
The instant invention relates to methods of and apparatus for monitoring transients in low inductance circuits and to a probe utilized to practice said method and apparatus. More particularly, the instant invention relates to methods of and apparatus for monitoring low inductance circuits, wherein the low inductance circuits include a pair of flat cable transmission lines. The instant invention is further directed to a probe for use in monitoring pairs of flat cable transmission lines.
Monitoring method and apparatus using high-frequency carrier
Haynes, H.D.
1996-04-30
A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device. 6 figs.
Shielding effects in the laser-generated copper plasma under reduced pressures of He atmosphere
NASA Astrophysics Data System (ADS)
Burger, M.; Pantić, D.; Nikolić, Z.; Djeniže, S.
2016-02-01
Irradiation of samples was performed with 6 ns, 1064 nm Nd:YAG laser. For an applied irradiance range (108-1010 W/cm2), the ablation process exhibits non-linear dependance. Ablated mass of the sample was directly determined using 100 ng resolution mass comparator after ablation under various pressures of helium. The ablation rates were dictated by plasma formation mechanisms as well as ambient conditions. However, the surrounding atmosphere did not significantly affect the value of threshold irradiance of about 2 ×109 W /cm2 for the onset of ablation mechanism change. This value is additionally verified via spectroscopic information from Cu I lines in the range from 0.4 to 1 μs after the laser pulse. Behaviour of spectral lines was monitored with respect to the laser pulse energy. Plasma diagnostics of axial electron density and excitation temperature distributions was performed under He pressure of 200 Torr. An influence of the possible shielding mechanisms responsible for the plasma absorption is discussed.
NASA Astrophysics Data System (ADS)
Boriano, A.; Bourhaleb, F.; Cirio, R.; Cirrone, G. A. P.; Cuttone, G.; Donetti, M.; Garelli, E.; Giordanengo, S.; Luparia, A.; Marchette, F.; Peroni, C.; Raffaele, L.; Sabini, M. G.; Valastro, L.
2006-01-01
Preliminary results are presented from a test of a parallel plate ionization chamber with the anode segmented in strips (MOPI) to be used as a beam monitor for therapeutical treatments on the 62 MeV proton beam line of the INFN-LNS Superconducting Cyclotron. Ocular pathologies have been treated at the Catana facility since March 2002. The detector, placed downstream of the patient collimator, will allow the measurement of the relevant beam diagnostic parameters during treatment such as integrated beam fluence, for dose determination; the beam baricentre, width and asymmetry will be obtained from the fluence profile sampled with a resolution of about 100 Urn at a rate up to 1 kHz with no dead time. In this test, carried out at LNS, the detector has been exposed to different beam shapes and the integrated fluence derived by the measured beam profiles has been compared with that obtained with other dosimeters normally used for treatment. The skewness of the beam profile has been measured and shown to be suitable to on-line check variations of the beam shape.
Real-time monitoring of railway infrastructures using fibre Bragg grating sensors
NASA Astrophysics Data System (ADS)
Roveri, N.; Carcaterra, A.; Sestieri, A.
2015-08-01
In this work we present the results of a field trial with a FBG sensor array system for the real time monitoring of railway traffic and for the structural health monitoring of both the railway track and train wheels. The test campaign is performed on the 2nd line of Milan metropolitan underground, employing more than 50 FBG sensors along 1.5 km of the rail track, where the trains are tested during daily passenger rail transport, with a roughly maximum speeds of 90 km/h. The measurements were continuatively performed for over 6 months, with a sampling frequency of about 400 Hz. The large amount of data/sensors allows a rather accurate statistical treatment of the measurement data and permits, with dedicated algorithms, the estimation of rail and wheel wear, key traffic parameters such as the number of axles, the train speed and load, and, in the next future, the detection of localized imperfections.
Antaki, Elizabeth M; Vellidis, George; Harris, Casey; Aminabadi, Peiman; Levy, Karen; Jay-Russell, Michele T
2016-10-01
Studies have shown that irrigation water can be a vector for pathogenic bacteria. Due to this, the Food Safety Modernization Act's (FSMA) produce safety rule requires that agricultural water directly applied to produce be safe and of adequate sanitary quality for use, which may pose a challenge for some farmers. The purpose of this research was to assess the presence and concentration of Salmonella and generic Escherichia coli in irrigation water from distribution systems in a mixed produce production region of southern Georgia. Water samples were collected during three growing seasons at three farms irrigating crops with surface water (Pond 1, Pond 2) or groundwater (Well) during 2012-2013. Salmonella and generic E. coli populations were monitored by culture and Most Probable Number (MPN). Confirmed isolates were characterized by pulsed-field gel electrophoresis and serotyping. In Pond 1, Salmonella was detected in 2/21 surface, 5/26 subsurface, 10/50 center pivot, and 0/16 solid set sprinkler head water samples. In Pond 2, Salmonella was detected in 2/18 surface, 1/18 subsurface, 6/36 drip line start, and 8/36 drip line end water samples. Twenty-six well pumps and 64 associated drip line water samples were negative. The overall mean Salmonella concentration for positive water samples was 0.03 MPN/100 mL (range <0.0011-1.8 MPN/100 mL). Nine Salmonella serovars comprising 22 pulsotypes were identified. Identical serovars and subtypes were found three times on the same day and location: Pond 1-Pivot-Cantaloupe (serovar Rubislaw), Pond 1-Pivot-Peanut (serovar Saintpaul), and Pond 2-Drip Line Start-Drip Line End-Yellow Squash (serovar III_16z10:e,n,x,z15). Generic E. coli was detected in water from both farm ponds and irrigation distribution systems, but the concentrations met FSMA microbial water quality criteria. The results from this study will allow producers in southern Georgia to better understand how potential pathogens move through irrigation distribution systems.
Study on Remote Monitoring System of Crossing and Spanning Tangent Tower
NASA Astrophysics Data System (ADS)
Chen, Da-bing; Zhang, Nai-long; Zhang, Meng-ge; Wang, Ze-hua; Zhang, Yan
2017-05-01
In order to grasp the vibration state of overhead transmission line and ensure the operational security of transmission line, the remote monitoring system of crossing and spanning tangent tower was studied. By use of this system, the displacement, velocity and acceleration of the tower, and the local weather data are collected automatically, displayed on computer of remote monitoring centre through wireless network, real-time collection and transmission of vibration signals are realized. The applying results show that the system is excellent in reliability and accuracy and so on. The system can be used to remote monitoring of transmission tower of UHV power transmission lines and in large spanning areas.
Qin, Qi-Zhong; Chen, Yu; Fu, Ting-Ting; Ding, Li; Han, Ling-Li; Li, Jian-Chao
2012-03-01
To understand electromagnetic radiation field strength and its influencing factors of certain 110-kV high-voltage lines in one urban area of Chongqing by measuring 110-kV high-voltage line's electromagnetic radiation level. According to the methodology as determined by the National Hygienic Standards, we selected certain adjacent residential buildings, high-voltage lines along a specific street and selected different distances around its vertical projection point as monitoring points. The levels of electromagnetic radiations were measured respectively. In this investigation within the frequency of 5-1,000 Hz both the electric field strength and magnetic field strength of each monitoring sites were lower than the public exposure standards as determined by the International Commission on Non-Ionizing Radiation Protection. However, the electrical field strength on the roof adjacent to the high-voltage lines was significantly higher than that as measured on the other floors in the same buildings (p < 0.05). The electromagnetic radiation measurements of different monitoring points, under the same high-voltage lines, showed the location which is nearer the high-voltage line maintain a consistently higher level of radiation than the more distant locations (p < 0.05). Electromagnetic radiation generated by high-voltage lines decreases proportionally to the distance from the lines. The buildings can to some extent shield (or absorb) the electric fields generated by high-voltage lines nearby. The electromagnetic radiation intensity near high-voltage lines may be mitigated or intensified by the manner in which the high-voltage lines are set up, and it merits attention for the potential impact on human health.
NASA Technical Reports Server (NTRS)
Diaz, Neil C.; Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.; Rutz, Jeff; Mudgett, Paul; Schultz, John
2004-01-01
Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.
Optoelectronic system of online measurements of unburned carbon in coal fly ash
NASA Astrophysics Data System (ADS)
Golas, Janusz; Jankowski, Henryk; Niewczas, Bogdan; Piechna, Janusz; Skiba, Antoni; Szkutnik, Wojciech; Szkutnik, Zdzislaw P.; Wartak, Ryszarda; Worek, Cezary
2001-08-01
Carbon-in-ash level is an important consideration for combustion efficiency as well as ash marketing. The optoelectronic analyzing system for on-line determination and monitoring of the u burned carbon content of ash samples is presented. The apparatus operates on the principle that carbon content is proportional to the reflectance of IR light. Ash samples are collected iso kinetically from the flue gas duct and placed in a sample tube with a flat glass bottom. The same is then exposed to a light. The reflectance intensity is used by the system's computer to determine residual carbon content from correlation curves. The sample is then air purged back to the duct or to the attached sample canister to enable laboratory check analysis. The total cycle time takes between 5 and 10 minutes. Real time result of carbon content with accuracy 0.3-0.7 percent are reported and can be used for boiler controlling.
Amchitka Island, Alaska, special sampling project 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy, Nevada Operations Office
2000-06-28
This 1997 special sampling project represents a special radiobiological sampling effort to augment the 1996 Long-Term Hydrological Monitoring Program (LTHMP) for Amchitka Island in Alaska. Lying in the western portion of the Aleutian Islands arc, near the International Date Line, Amchitka Island is one of the southernmost islands of the Rat Island Chain. Between 1965 and 1971, the U.S. Atomic Energy Commission conducted three underground nuclear tests on Amchitka Island. In 1996, Greenpeace collected biota samples and speculated that several long-lived, man-made radionuclides detected (i.e., americium-241, plutonium-239 and -240, beryllium-7, and cesium-137) leaked into the surface environment from underground cavitiesmore » created during the testing. The nuclides of interest are detected at extremely low concentrations throughout the environment. The objectives of this special sampling project were to scientifically refute the Greenpeace conclusions that the underground cavities were leaking contaminants to the surface. This was achieved by first confirming the presence of these radionuclides in the Amchitka Island surface environment and, second, if the radionuclides were present, determining if the source is the underground cavity or worldwide fallout. This special sampling and analysis determined that the only nonfallout-related radionuclide detected was a low level of tritium from the Long Shot test, which had been previously documented. The tritium contamination is monitored and continues a decreasing trend due to radioactive decay and dilution.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... DoD published a proposed rule in the Federal Register at 76 FR 21847 on April 19, 2011, to add DFARS..., the contract line item may be for a desktop computer, but the actual items delivered, invoiced, and..., Desktop with 20 EA CPU, Monitor, Keyboard and Mouse. Alternative line-item structure offer where monitors...
Phillips, Andrew; Cambiano, Valentina; Nakagawa, Fumiyo; Mabugu, Travor; Magubu, Travor; Miners, Alec; Ford, Debbie; Pillay, Deenan; De Luca, Andrea; Lundgren, Jens; Revill, Paul
2014-01-01
To guide future need for cheap resistance tests for use in low income settings, we assessed cost-effectiveness of drug resistance testing as part of monitoring of people on first line ART - with switching from first to second line ART being conditional on NNRTI drug resistance mutations being identified. An individual level simulation model of HIV transmission, progression and the effect of ART which accounts for adherence and resistance development was used to compare outcomes of various potential monitoring strategies in a typical low income setting in sub-Saharan Africa. Underlying monitoring strategies considered were based on clinical disease, CD4 count or viral load. Within each we considered a strategy in which no further measures are performed, one with a viral load measure to confirm failure, and one with both a viral load measure and a resistance test. Predicted outcomes were assessed over 2015-2025 in terms of viral suppression, first line failure, switching to second line regimen, death, HIV incidence, disability-adjusted-life-years averted and costs. Potential future low costs of resistance tests ($30) were used. The most effective strategy, in terms of DALYs averted, was one using viral load monitoring without confirmation. The incremental cost-effectiveness ratio for this strategy was $2113 (the same as that for viral load monitoring with confirmation). ART monitoring strategies which involved resistance testing did not emerge as being more effective or cost effective than strategies not using it. The slightly reduced ART costs resulting from use of resistance testing, due to less use of second line regimens, was of similar magnitude to the costs of resistance tests. Use of resistance testing at the time of first line failure as part of the decision whether to switch to second line therapy was not cost-effective, even though the test was assumed to be very inexpensive.
APDS: Autonomous Pathogen Detection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langlois, R G; Brown, S; Burris, L
An early warning system to counter bioterrorism, the Autonomous Pathogen Detection System (APDS) continuously monitors the environment for the presence of biological pathogens (e.g., anthrax) and once detected, it sounds an alarm much like a smoke detector warns of a fire. Long before September 11, 2001, this system was being developed to protect domestic venues and events including performing arts centers, mass transit systems, major sporting and entertainment events, and other high profile situations in which the public is at risk of becoming a target of bioterrorist attacks. Customizing off-the-shelf components and developing new components, a multidisciplinary team developed APDS,more » a stand-alone system for rapid, continuous monitoring of multiple airborne biological threat agents in the environment. The completely automated APDS samples the air, prepares fluid samples in-line, and performs two orthogonal tests: immunoassay and nucleic acid detection. When compared to competing technologies, APDS is unprecedented in terms of flexibility and system performance.« less
Dubelaar, G B; Gerritzen, P L; Beeker, A E; Jonker, R R; Tangen, K
1999-12-01
The high costs of microscopical determination and counting of phytoplankton often limit sampling frequencies below an acceptable level for the monitoring of dynamic ecosystems. Although having a limited discrimination power, flow cytometry allows the analysis of large numbers of samples to a level that is sufficient for many basic monitoring jobs. For this purpose, flow cytometers should not be restricted to research laboratories. We report here on the development of an in situ flow cytometer for autonomous operation inside a small moored buoy or on other platforms. Operational specifications served a wide range of applications in the aquatic field. Specific conditions had to be met with respect to the operation platform and autonomy. A small, battery-operated flow cytometer resulted, requiring no external sheath fluid supply. Because it was designed to operate in a buoy, we call it CytoBuoy. Sampling, analysis, and radio transmission of the data proceed automatically at user-defined intervals. A powerful feature is the acquisition and radio transmission of full detector pulse shapes of each particle. This provides valuable morphological information for particles larger than the 5-microm laser focus. CytoBuoy allows on-line in situ particle analysis, estimation of phytoplankton biomass, and discrimination between different phytoplankton groups. This will increase the applicability of flow cytometry in the field of environmental monitoring. Copyright 1999 Wiley-Liss, Inc.
LEMON - LHC Era Monitoring for Large-Scale Infrastructures
NASA Astrophysics Data System (ADS)
Marian, Babik; Ivan, Fedorko; Nicholas, Hook; Hector, Lansdale Thomas; Daniel, Lenkes; Miroslav, Siket; Denis, Waldron
2011-12-01
At the present time computer centres are facing a massive rise in virtualization and cloud computing as these solutions bring advantages to service providers and consolidate the computer centre resources. However, as a result the monitoring complexity is increasing. Computer centre management requires not only to monitor servers, network equipment and associated software but also to collect additional environment and facilities data (e.g. temperature, power consumption, cooling efficiency, etc.) to have also a good overview of the infrastructure performance. The LHC Era Monitoring (Lemon) system is addressing these requirements for a very large scale infrastructure. The Lemon agent that collects data on every client and forwards the samples to the central measurement repository provides a flexible interface that allows rapid development of new sensors. The system allows also to report on behalf of remote devices such as switches and power supplies. Online and historical data can be visualized via a web-based interface or retrieved via command-line tools. The Lemon Alarm System component can be used for notifying the operator about error situations. In this article, an overview of the Lemon monitoring is provided together with a description of the CERN LEMON production instance. No direct comparison is made with other monitoring tool.
High throughput wafer defect monitor for integrated metrology applications in photolithography
NASA Astrophysics Data System (ADS)
Rao, Nagaraja; Kinney, Patrick; Gupta, Anand
2008-03-01
The traditional approach to semiconductor wafer inspection is based on the use of stand-alone metrology tools, which while highly sensitive, are large, expensive and slow, requiring inspection to be performed off-line and on a lot sampling basis. Due to the long cycle times and sparse sampling, the current wafer inspection approach is not suited to rapid detection of process excursions that affect yield. The semiconductor industry is gradually moving towards deploying integrated metrology tools for real-time "monitoring" of product wafers during the manufacturing process. Integrated metrology aims to provide end-users with rapid feedback of problems during the manufacturing process, and the benefit of increased yield, and reduced rework and scrap. The approach of monitoring 100% of the wafers being processed requires some trade-off in sensitivity compared to traditional standalone metrology tools, but not by much. This paper describes a compact, low-cost wafer defect monitor suitable for integrated metrology applications and capable of detecting submicron defects on semiconductor wafers at an inspection rate of about 10 seconds per wafer (or 360 wafers per hour). The wafer monitor uses a whole wafer imaging approach to detect defects on both un-patterned and patterned wafers. Laboratory tests with a prototype system have demonstrated sensitivity down to 0.3 µm on un-patterned wafers and down to 1 µm on patterned wafers, at inspection rates of 10 seconds per wafer. An ideal application for this technology is preventing photolithography defects such as "hot spots" by implementing a wafer backside monitoring step prior to exposing wafers in the lithography step.
NASA Technical Reports Server (NTRS)
Hypes, W. D.; Ohlhorst, C. W.
1977-01-01
Two remote sensor evaluation experiments are discussed. One experiment was conducted at the DuPont acid-dump site off the Delaware coast. The second was conducted at an organic waste outfall in the Delaware River. The operational objective of obtaining simultaneous sea truth sampling with remote sensors overpasses was met. Descriptions of the test sites, sensors, sensor platforms, flight lines, sea truth data collected, and operational chronology are presented.
On-Line Modal State Monitoring of Slowly Time-Varying Structures
NASA Technical Reports Server (NTRS)
Johnson, Erik A.; Bergman, Lawrence A.; Voulgaris, Petros G.
1997-01-01
Monitoring the dynamic response of structures is often performed for a variety of reasons. These reasons include condition-based maintenance, health monitoring, performance improvements, and control. In many cases the data analysis that is performed is part of a repetitive decision-making process, and in these cases the development of effective on-line monitoring schemes help to speed the decision-making process and reduce the risk of erroneous decisions. This report investigates the use of spatial modal filters for tracking the dynamics of slowly time-varying linear structures. The report includes an overview of modal filter theory followed by an overview of several structural system identification methods. Included in this discussion and comparison are H-infinity, eigensystem realization, and several time-domain least squares approaches. Finally, a two-stage adaptive on-line monitoring scheme is developed and evaluated.
NASA Astrophysics Data System (ADS)
Yegoshina, O. V.; Voronov, V. N.; Yarovoy, V. O.; Bolshakova, N. A.
2017-11-01
There are many problems in domestic energy at the present that require urgent solutions in the near future. One of these problems - the aging of the main and auxiliary equipment. Wear of equipment is the cause of decrease reliability and efficiency of power plants. Reliability of the equipment are associated with the introduction of cycle chemistry monitoring system. The most damageable equipment’s are boilers (52.2 %), turbines (12.6 %) and heating systems (12.3 %) according to the review of failure rate on the power plants. The most part of the damageability of the boiler is heated surfaces (73.2 %). According to the Russian technical requirements, the monitoring systems are responsible to reduce damageability the boiler heating surfaces and to increase the reliability of the equipment. All power units capacity of over 50 MW are equipped with cycle chemistry monitoring systems in order to maintain water chemistry within operating limits. The main idea of cycle chemistry monitoring systems is to improve water chemistry at power plants. According to the guidelines, cycle chemistry monitoring systems of a single unit depends on its type (drum or once-through boiler) and consists of: 20…50 parameters of on-line chemical analyzers; 20…30 «grab» sample analyses (daily) and about 15…20 on-line monitored operating parameters. The operator of modern power plant uses with many data at different points of steam/water cycle. Operators do not can estimate quality of the cycle chemistry due to the large volume of daily and every shift information and dispersion of data, lack of systematization. In this paper, an algorithm for calculating the quality index developed for improving control the water chemistry of the condensate, feed water and prevent scaling and corrosion in the steam/water cycle.
Long-term Ultraviolet Monitoring of a Tidal Disruption Event at only 90 Mpc
NASA Astrophysics Data System (ADS)
Maksym, W. Peter; Cenko, Bradley; Eracleous, Michael; Keel, William C.; Irwin, Jimmy; Sigurdsson, Steinn; Fruchter, Andrew; Gezari, Suvi; Bogdanovic, Tamara; Roth, Katherine
2018-01-01
At only 90 Mpc, ASASSN-14li is one of the nearest tidal disruption events (TDEs) to permit high-quality multi-wavelength monitoring, and is the first TDE with ultraviolet spectroscopic observations between Lyman alpha and Mg II λ2800Å. We present results from a continued long-term ultraviolet monitoring campaign with the Hubble Space Telescope. Prior observations had showed an array of broad emission lines common to Seyferts. Surpisingly, however, uncommon lines such as He II λ1640Å, N III] λ1750Å and N IV] λ1486Å had been enhanced, whereas others such as C III] λ1909Å and Mg II λ2800Å are notably absent. Our campaign shows contnued continuum emission accompanied by the gradual disappearance of broad line emission, which may indicate the gradual disappearance of a TDE wind as the accretion rate declines to sub-critical levels. Variability of the semi-forbidden lines supports stimulation by the TDE. A continued absence of low-ionization lines like Mg II in our monitoring may constrain the presence of ionized unbound material at large radii.
Nondestructive Testing of Overhead Transmission LINES—NUMERICAL and Experimental Investigation
NASA Astrophysics Data System (ADS)
Kulkarni, S.; Hurlebaus, S.
2009-03-01
Overhead transmission lines are periodically inspected using both on-ground and helicopter-aided visual inspection. Factors including sun glare, cloud cover, close proximity to power lines and the rapidly changing visual circumstances make airborne inspection of power lines a particularly hazardous task. In this study, a finite element model is developed that can be used to create the theoretical dispersion curves of an overhead transmission line. The numerical results are then verified with experimental test using a non-contact and broadband laser detection technique. The methodology developed in this study can be further extended to a continuous monitoring system and be applied to other cable monitoring applications, such as bridge cable monitoring, which would otherwise put human inspectors at risk.
Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L
2011-01-01
To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit Dose Distribution System errors at initial, intermediate and final stages of the process, improving the involvement of the Pharmacy Department and ward nurses. Copyright © 2009 SEFH. Published by Elsevier Espana. All rights reserved.
Hinkle, Stephen J.; Weick, Rodney J.; Johnson, Jill M.; Cahill, Jeffery D.; Smith, Steven G.; Rich, Barbara J.
2005-01-01
The occurrence of organic wastewater compounds (components of 'personal care products' and other common household chemicals), pharmaceuticals (human prescription and nonprescription medical drugs), and coliphage (viruses that infect coliform bacteria, and found in high concentrations in municipal wastewater) in onsite wastewater (septic tank effluent) and in a shallow, unconfined, sandy aquifer that serves as the primary source of drinking water for most residents near La Pine, Oregon, was documented. Samples from two types of observation networks provided basic occurrence data for onsite wastewater and downgradient ground water. One observation network was a group of 28 traditional and innovative (advanced treatment) onsite wastewater treatment systems and associated downgradient drainfield monitoring wells, referred to as the 'innovative systems network'. The drainfield monitoring wells were located adjacent to or under onsite wastewater treatment system drainfield lines. Another observation network, termed the 'transect network', consisted of 31 wells distributed among three transects of temporary, stainless-steel-screened, direct-push monitoring wells installed along three plumes of onsite wastewater. The transect network, by virtue of its design, also provided a basis for increased understanding of the transport of analytes in natural systems. Coliphage were frequently detected in onsite wastewater. Coliphage concentrations in onsite wastewater were highly variable, ranging from less than 1 to 3,000,000 plaque forming units per 100 milliliters. Coliphage were occasionally detected (eight occurrences) at low concentrations in samples from wells located downgradient from onsite wastewater treatment system drainfield lines. However, coliphage concentrations were below method detection limits in replicate or repeat samples collected from the eight sites. The consistent absence of coliphage detections in the replicate or repeat samples is interpreted to indicate that the detections reported for ground-water samples represented low-level field or laboratory contamination, and it would appear that coliphage were effectively attenuated to less than 1 PFU/100 mL over distances of several feet of transport in the La Pine aquifer and (or) overlying unsaturated zone. Organic wastewater compounds were frequently detected in onsite wastewater. Of the 63 organic wastewater compounds in the analytical schedule, 45 were detected in the 21 samples of onsite wastewater. Concentrations of organic wastewater compounds reached a maximum of 1,300 ug/L (p-cresol). Caffeine was detected at concentrations as high as 320 ug/L. Fourteen of the 45 compounds were detected in more than 90 percent of onsite wastewater samples. Fewer (nine) organic wastewater compounds were detected in ground water, despite the presence of nitrate and chloride likely from onsite wastewater sources. The nine organic wastewater compounds that were detected in ground-water samples were acetyl-hexamethyl-tetrahydro-naphthalene (AHTN), caffeine, cholesterol, hexahydrohexamethyl-cyclopentabenzopyran, N,N-diethyl-meta-toluamide (DEET), tetrachloroethene, tris (2-chloroethyl) phosphate, tris (dichloroisopropyl) phosphate, and tributyl phosphate. Frequent detection of household-chemical type organic wastewater compounds in onsite wastewater provides evidence that some of these organic wastewater compounds may be useful indicators of human waste effluent dispersal in some hydrologic environments. The occurrence of organic wastewater compounds in ground water downgradient from onsite wastewater treatment systems demonstrates that a subgroup of organic wastewater compounds is transported in the La Pine aquifer. The consistently low concentrations (generally less than 1 ug/L) of organic wastewater compounds in water samples collected from wells located no more than 19 feet from drainfield lines indicates that the reactivity (sorption, degradation) of this suite of organic waste
Presley, Todd K.; Jamison, Marcael T.J.
2010-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.
Neale, Peta A; Altenburger, Rolf; Aït-Aïssa, Selim; Brion, François; Busch, Wibke; de Aragão Umbuzeiro, Gisela; Denison, Michael S; Du Pasquier, David; Hilscherová, Klára; Hollert, Henner; Morales, Daniel A; Novák, Jiří; Schlichting, Rita; Seiler, Thomas-Benjamin; Serra, Helene; Shao, Ying; Tindall, Andrew J; Tollefsen, Knut Erik; Williams, Timothy D; Escher, Beate I
2017-10-15
Surface waters can contain a diverse range of organic pollutants, including pesticides, pharmaceuticals and industrial compounds. While bioassays have been used for water quality monitoring, there is limited knowledge regarding the effects of individual micropollutants and their relationship to the overall mixture effect in water samples. In this study, a battery of in vitro bioassays based on human and fish cell lines and whole organism assays using bacteria, algae, daphnids and fish embryos was assembled for use in water quality monitoring. The selection of bioassays was guided by the principles of adverse outcome pathways in order to cover relevant steps in toxicity pathways known to be triggered by environmental water samples. The effects of 34 water pollutants, which were selected based on hazard quotients, available environmental quality standards and mode of action information, were fingerprinted in the bioassay test battery. There was a relatively good agreement between the experimental results and available literature effect data. The majority of the chemicals were active in the assays indicative of apical effects, while fewer chemicals had a response in the specific reporter gene assays, but these effects were typically triggered at lower concentrations. The single chemical effect data were used to improve published mixture toxicity modeling of water samples from the Danube River. While there was a slight increase in the fraction of the bioanalytical equivalents explained for the Danube River samples, for some endpoints less than 1% of the observed effect could be explained by the studied chemicals. The new mixture models essentially confirmed previous findings from many studies monitoring water quality using both chemical analysis and bioanalytical tools. In short, our results indicate that many more chemicals contribute to the biological effect than those that are typically quantified by chemical monitoring programs or those regulated by environmental quality standards. This study not only demonstrates the utility of fingerprinting single chemicals for an improved understanding of the biological effect of pollutants, but also highlights the need to apply bioassays for water quality monitoring in order to prevent underestimation of the overall biological effect. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
N /A
2006-01-01
This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2006 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2006 will be in accordance with DOE Order 540.1 requirements and the following goals: {sm_bullet} to maintain surveillance of existing and potential groundwater contamination sources; {sm_bullet} to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminantsmore » are most likely to migrate beyond the Oak Ridge Reservation property line; {sm_bullet} to identify and characterize long-term trends in groundwater quality at Y-12; and ! to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2006 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation (Figure A.1). Modifications to the CY 2006 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2006 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3; sample collection methods and procedures are described in Section 4; and Section 5 lists the documents cited for more detailed operational and technical information. The narrative sections of the report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. The monitoring frequency and selection criteria for each sampling location is in Appendix C. Laboratory requirements (bottle lists, holding times, etc.) are provided in Appendix D. If issued, addenda to this plan will be inserted in Appendix E, and Groundwater Monitoring Schedules (when issued) will be inserted in Appendix F. Guidance for managing purged groundwater is provided in Appendix G.« less
Chen, Chun-Hsien; Chao, Yu-Ying; Lin, Yi-Hui; Chen, Yen-Ling
2018-04-27
The on-line preconcentration technique of field-enhanced sample stacking and sweeping (FESS-sweeping) are combined with dispersive liquid-liquid microextraction (DLLME) to monitor the concentrations of finasteride, which is used in the treatment of androgenetic alopecia, and its metabolite, finasteride carboxylic acid (M3), in urine samples. DLLME is used to concentrate and eliminate the interferences of urine samples and uses chloroform as an extracting solvent and acetonitrile as a disperser solvent. A high conductivity buffer (HCB) was introduced into capillary and then sample plug (90.7% capillary length) was injected into capillary. After applying voltage, the sodium dodecyl sulfate (SDS) swept the analytes from the low conductivity sample solution into HCB. The analytes were concentrated on the field-enhanced sample stacking boundary. The limit of detection for the analytes is 20 ng mL -1 . The sensitivity enrichment of finasteride and M3 are 362-fold and 480-fold, respectively, compared with the conventional MEKC method. The on-line preconcentration technique of field-enhanced sample stacking and sweeping possess good selectivity because the endogenous steroid did not interfere the detection of finasteride and M3. The analytical technique is applied to investigate the concentrations in urine samples from patients who have been administered finasteride for the treatment of androgenetic alopecia; the amount of M3 detected in 12 h was 72.69 ± 4.18 μg. Copyright © 2018 Elsevier B.V. All rights reserved.
Yao, Mingyin; Yang, Hui; Huang, Lin; Chen, Tianbing; Rao, Gangfu; Liu, Muhua
2017-05-10
In seeking a novel method with the ability of green analysis in monitoring toxic heavy metals residue in fresh leafy vegetables, laser-induced breakdown spectroscopy (LIBS) was applied to prove its capability in performing this work. The spectra of fresh vegetable samples polluted in the lab were collected by optimized LIBS experimental setup, and the reference concentrations of cadmium (Cd) from samples were obtained by conventional atomic absorption spectroscopy after wet digestion. The direct calibration employing intensity of single Cd line and Cd concentration exposed the weakness of this calibration method. Furthermore, the accuracy of linear calibration can be improved a little by triple Cd lines as characteristic variables, especially after the spectra were pretreated. However, it is not enough in predicting Cd in samples. Therefore, partial least-squares regression (PLSR) was utilized to enhance the robustness of quantitative analysis. The results of the PLSR model showed that the prediction accuracy of the Cd target can meet the requirement of determination in food safety. This investigation presented that LIBS is a promising and emerging method in analyzing toxic compositions in agricultural products, especially combined with suitable chemometrics.
Research on a Lamb Wave and Particle Filter-Based On-Line Crack Propagation Prognosis Method.
Chen, Jian; Yuan, Shenfang; Qiu, Lei; Cai, Jian; Yang, Weibo
2016-03-03
Prognostics and health management techniques have drawn widespread attention due to their ability to facilitate maintenance activities based on need. On-line prognosis of fatigue crack propagation can offer information for optimizing operation and maintenance strategies in real-time. This paper proposes a Lamb wave-particle filter (LW-PF)-based method for on-line prognosis of fatigue crack propagation which takes advantages of the possibility of on-line monitoring to evaluate the actual crack length and uses a particle filter to deal with the crack evolution and monitoring uncertainties. The piezoelectric transducers (PZTs)-based active Lamb wave method is adopted for on-line crack monitoring. The state space model relating to crack propagation is established by the data-driven and finite element methods. Fatigue experiments performed on hole-edge crack specimens have validated the advantages of the proposed method.
NASA Astrophysics Data System (ADS)
Huang, J. J.; Lin, S. C.; Löwemark, L.; Liou, Y. H.; Chang, Q. M.; Chang, T. K.; Wei, K. Y.; Croudace, I. W. C.
2017-12-01
Due to the rapid industrial expansion, environments are subject to irregular fluctuations and spatial distributions in pollutant concentrations. This study proposes to use ion exchange resin accompanied with the XRF-scanning technique to monitor environmental pollution. As a passive sampling sorbent, the use of ion exchange resin provides a rapid, low cost and simple method to detect episodic pollution signals with a high spatial sampling density. In order to digest large quantities of samples, the fast and non-destructive Itrax-XRF core scanner has been introduced to assess elemental concentrations in the resin samples. Although the XRF scanning results are often considered as a semi-quantitative measurement due to possible absorption or scattering caused by the physical variabilities of scanned materials, the use of resin can minimize such influences owing to the standarization of the sample matrix. In this study, 17 lab-prepared standard resin samples were scanned with the Itrax-XRF core scanner (at 100 s exposure time with the Mo-tube) and compared with the absolute elemental concentrations. Six elements generally used in pollution studies (Cr, Mn, Ni, Cu, Zn, and Pb) were selected, and their regression lines and correlation coefficients were determined. In addition, 5 standard resin samples were scanned at different exposure time settings (1 s, 5 s, 15 s, 30 s, 100 s) to address the influence of exposure time on the accuracy of the measurements. The results show that within the test range (from few ppm to thousands ppm), the correlation coefficients are higher than 0.97, even at the shortest exposure time (1 s). Furthermore, a pilot field survey with 30 resin samples has been conducted in a potentially polluted farm area in central Taiwan to demonstrate the feasibility of this novel approach. The polluted hot zones could be identified and the properties and sources of wastewater pollution can therefore be traced over large areas for the purposes of environmental monitoring and environmental forensics.
NASA Astrophysics Data System (ADS)
Matthews, Q.; Jirasek, A.; Lum, J. J.; Brolo, A. G.
2011-11-01
This work applies noninvasive single-cell Raman spectroscopy (RS) and principal component analysis (PCA) to analyze and correlate radiation-induced biochemical changes in a panel of human tumour cell lines that vary by tissue of origin, p53 status and intrinsic radiosensitivity. Six human tumour cell lines, derived from prostate (DU145, PC3 and LNCaP), breast (MDA-MB-231 and MCF7) and lung (H460), were irradiated in vitro with single fractions (15, 30 or 50 Gy) of 6 MV photons. Remaining live cells were harvested for RS analysis at 0, 24, 48 and 72 h post-irradiation, along with unirradiated controls. Single-cell Raman spectra were acquired from 20 cells per sample utilizing a 785 nm excitation laser. All spectra (200 per cell line) were individually post-processed using established methods and the total data set for each cell line was analyzed with PCA using standard algorithms. One radiation-induced PCA component was detected for each cell line by identification of statistically significant changes in the PCA score distributions for irradiated samples, as compared to unirradiated samples, in the first 24-72 h post-irradiation. These RS response signatures arise from radiation-induced changes in cellular concentrations of aromatic amino acids, conformational protein structures and certain nucleic acid and lipid functional groups. Correlation analysis between the radiation-induced PCA components separates the cell lines into three distinct RS response categories: R1 (H460 and MCF7), R2 (MDA-MB-231 and PC3) and R3 (DU145 and LNCaP). These RS categories partially segregate according to radiosensitivity, as the R1 and R2 cell lines are radioresistant (SF2 > 0.6) and the R3 cell lines are radiosensitive (SF2 < 0.5). The R1 and R2 cell lines further segregate according to p53 gene status, corroborated by cell cycle analysis post-irradiation. Potential radiation-induced biochemical response mechanisms underlying our RS observations are proposed, such as (1) the regulated synthesis and degradation of structured proteins and (2) the expression of anti-apoptosis factors or other survival signals. This study demonstrates the utility of RS for noninvasive radiobiological analysis of tumour cell radiation response, and indicates the potential for future RS studies designed to investigate, monitor or predict radiation response.
Liu, Xiaoxia; Yang, Jiqing; Sun, Shucheng; Guo, Liping; Yang, Li
2016-10-01
We present here an easy-to-operate and efficient method for enzyme and inhibition assays of urease, which is a widely distributed and important enzyme that catalyzes the hydrolysis of urea to ammonia and CO 2 . The assay was achieved by integrating CE technique and rapid on-line derivatization method, allowing us to continuously drive the sample to the capillary, thus to measure the amount of the product ammonia from the beginning to the end of the reaction. The method exhibits excellent repeatability with RSD as low as 2.5% for the initial reaction rate (n = 5), with the LOD of ammonia of 20 μM (S/N = 5). The enzyme activity as well as the inhibition of urease by Cu 2+ were investigated using the present method. The results show that Cu 2+ is a noncompetitive inhibitor on urease, in accordance with the result published in the literature. The enzyme activity and inhibition kinetic constants were obtained and were found to be consistent with the results of traditional off-line enzyme assays. Our study indicates that the present approach is a reliable and convenient method for analysis of the urease activity and inhibition kinetics by continuous on-line monitoring of the ammonium formation based on CE. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Automated in-line gel filtration for native state mass spectrometry.
Waitt, Greg M; Xu, Robert; Wisely, G Bruce; Williams, Jon D
2008-02-01
Characterization of protein-ligand complexes by nondenaturing mass spectrometry provides direct evidence of drug-like molecules binding with potential therapeutic targets. Typically, protein-ligand complexes to be analyzed contain buffer salts, detergents, and other additives to enhance protein solubility, all of which make the sample unable to be analyzed directly by electrospray ionization mass spectrometry. This work describes an in-line gel-filtration method that has been automated and optimized. Automation was achieved using commercial HPLC equipment. Gel column parameters that were optimized include: column dimensions, flow rate, packing material type, particle size, and molecular weight cut-off. Under optimal conditions, desalted protein ions are detected 4 min after injection and the analysis is completed in 20 min. The gel column retains good performance even after >200 injections. A demonstration for using the in-line gel-filtration system is shown for monitoring the exchange of fatty acids from the pocket of a nuclear hormone receptor, peroxisome proliferator activator-delta (PPARdelta) with a tool compound. Additional utilities of in-line gel-filtration mass spectrometry system will also be discussed.
Wang, Meng; Slaney, Thomas; Mabrouk, Omar; Kennedy, Robert T.
2010-01-01
An off-line in vivo neurochemical monitoring approach was developed based on collecting nanoliter microdialysate fractions as an array of “plugs” segmented by immiscible oil in a piece of Teflon tubing. The dialysis probe was integrated with the plug generator in a polydimethlysiloxane microfluidic device that could be mounted on the subject. The microfluidic device also allowed derivatization reagents to be added to the plugs for fluorescence detection of analytes. Using the device, 2 nL fractions corresponding to 1–20 ms sampling times depending upon dialysis flow rate, were collected. Because axial dispersion was prevented between them, each plug acted as a discrete sample collection vial and temporal resolution was not lost by mixing or diffusion during transport. In vitro tests of the system revealed that the temporal resolution of the system was as good as 2 s and was limited by mass transport effects within the dialysis probe. After collection of dialysate fractions, they were pumped into a glass microfluidic chip that automatically analyzed the plugs by capillary electrophoresis with laser-induced fluorescence at 50 s intervals. By using a relatively low flow rate during transfer to the chip, the temporal resolution of the samples could be preserved despite the relatively slow analysis time. The system was used to detect rapid dynamics in neuroactive amino acids evoked by microinjecting the glutamate uptake inhibitor L-trans-pyrrolidine-2,4-dicarboxylic acid (PDC) or K+ into the striatum of anesthetized rats. The resulted showed increases in neurotransmitter efflux that reached a peak in 20 s for PDC and 13 s for K+. PMID:20447417
Sustainable HIV treatment in Africa through viral-load-informed differentiated care.
Phillips, Andrew; Shroufi, Amir; Vojnov, Lara; Cohn, Jennifer; Roberts, Teri; Ellman, Tom; Bonner, Kimberly; Rousseau, Christine; Garnett, Geoff; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Bansi-Matharu, Loveleen; Miners, Alec; Lundgren, Jens D; Eaton, Jeffrey W; Parkes-Ratanshi, Rosalind; Katz, Zachary; Maman, David; Ford, Nathan; Vitoria, Marco; Doherty, Meg; Dowdy, David; Nichols, Brooke; Murtagh, Maurine; Wareham, Meghan; Palamountain, Kara M; Chakanyuka Musanhu, Christine; Stevens, Wendy; Katzenstein, David; Ciaranello, Andrea; Barnabas, Ruanne; Braithwaite, R Scott; Bendavid, Eran; Nathoo, Kusum J; van de Vijver, David; Wilson, David P; Holmes, Charles; Bershteyn, Anna; Walker, Simon; Raizes, Elliot; Jani, Ilesh; Nelson, Lisa J; Peeling, Rosanna; Terris-Prestholt, Fern; Murungu, Joseph; Mutasa-Apollo, Tsitsi; Hallett, Timothy B; Revill, Paul
2015-12-03
There are inefficiencies in current approaches to monitoring patients on antiretroviral therapy in sub-Saharan Africa. Patients typically attend clinics every 1 to 3 months for clinical assessment. The clinic costs are comparable with the costs of the drugs themselves and CD4 counts are measured every 6 months, but patients are rarely switched to second-line therapies. To ensure sustainability of treatment programmes, a transition to more cost-effective delivery of antiretroviral therapy is needed. In contrast to the CD4 count, measurement of the level of HIV RNA in plasma (the viral load) provides a direct measure of the current treatment effect. Viral-load-informed differentiated care is a means of tailoring care so that those with suppressed viral load visit the clinic less frequently and attention is focussed on those with unsuppressed viral load to promote adherence and timely switching to a second-line regimen. The most feasible approach to measuring viral load in many countries is to collect dried blood spot samples for testing in regional laboratories; however, there have been concerns over the sensitivity and specificity of this approach to define treatment failure and the delay in returning results to the clinic. We use modelling to synthesize evidence and evaluate the cost-effectiveness of viral-load-informed differentiated care, accounting for limitations of dried blood sample testing. We find that viral-load-informed differentiated care using dried blood sample testing is cost-effective and is a recommended strategy for patient monitoring, although further empirical evidence as the approach is rolled out would be of value. We also explore the potential benefits of point-of-care viral load tests that may become available in the future.
Attwood, S E; Ball, C S; Barlow, A P; Jenkinson, L; Norris, T L; Watson, A
1993-01-01
Patients with Barrett's columnar lined lower oesophagus have severe acid gastrooesophageal reflux and may develop complications, including ulceration, stricture, and carcinoma. The aim of this study was to establish if a relationship exists between the pH profile in the oesophagus and stomach and the development of complications in patients with Barrett's columnar lined lower oesophagus. Twenty four hour ambulatory oesophageal pH monitoring was performed in 26 patients with Barrett's columnar lined lower oesophagus and combined with 24 hour ambulatory gastric pH monitoring in 16. Ten of the 26 with Barrett's columnar lined lower oesophagus had complications including stricture (eight), deep ulceration (one), and carcinoma (one). Oesophageal acid exposure (% time < pH 4) was similar in patients with or without complications (19.2% v 19.3% p > 0.05). Oesophageal alkaline exposure (% time > pH 7) was greater in patients with complications (24.2% v 8.4% p > 0.05). Of the 16 patients who underwent gastric pH monitoring there was a clear relationship between gastric and oesophageal alkalinisation in 13. These results support the hypothesis that complications in Barrett's columnar lined lower oesophagus develop in association with increased exposure of the oesophagus to an alkaline environment which appears to be secondary to duodenogastric reflux. The routine use of 24 hour ambulatory gastric pH monitoring in conjunction with oesophageal pH monitoring can help identify those patients at risk. PMID:8432439
Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen
2016-01-01
To monitor two-dimensional (2D) distributions of temperature and H2O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors' knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H2O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm(-1) (1343.3 nm) and 7185.6 cm(-1) (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H2O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H2O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.
NASA Astrophysics Data System (ADS)
Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen
2016-01-01
To monitor two-dimensional (2D) distributions of temperature and H2O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors' knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H2O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm-1 (1343.3 nm) and 7185.6 cm-1 (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H2O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H2O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Lijun, E-mail: lijunxu@buaa.edu.cn; Liu, Chang; Jing, Wenyang
2016-01-15
To monitor two-dimensional (2D) distributions of temperature and H{sub 2}O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors’ knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H{sub 2}O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm{sup −1} (1343.3 nm) and 7185.6 cm{sup −1} (1391.67 nm), respectively. The tomographicmore » sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H{sub 2}O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H{sub 2}O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schimoia, Jaderson S.; Storchi-Bergmann, Thaisa; Grupe, Dirk
2015-02-10
Recent studies have suggested that the short-timescale (≲ 7 days) variability of the broad (∼10,000 km s{sup –1}) double-peaked Hα profile of the LINER nucleus of NGC 1097 could be driven by a variable X-ray emission from a central radiatively inefficient accretion flow. To test this scenario, we have monitored the NGC 1097 nucleus in X-ray and UV continuum with Swift and the Hα flux and profile in the optical spectrum using SOAR and Gemini-South from 2012 August to 2013 February. During the monitoring campaign, the Hα flux remained at a very low level—three times lower than the maximum flux observed in previousmore » campaigns and showing only limited (∼20%) variability. The X-ray variations were small, only ∼13% throughout the campaign, while the UV did not show significant variations. We concluded that the timescale of the Hα profile variation is close to the sampling interval of the optical observations, which results in only a marginal correlation between the X-ray and Hα fluxes. We have caught the active galaxy nucleus in NGC 1097 in a very low activity state, in which the ionizing source was very weak and capable of ionizing just the innermost part of the gas in the disk. Nonetheless, the data presented here still support the picture in which the gas that emits the broad double-peaked Balmer lines is illuminated/ionized by a source of high-energy photons which is located interior to the inner radius of the line-emitting part of the disk.« less
Switchable in-line monitor for multi-dimensional multiplexed photonic integrated circuit.
Chen, Guanyu; Yu, Yu; Ye, Mengyuan; Zhang, Xinliang
2016-06-27
A flexible monitor suitable for the discrimination of on-chip transmitted mode division multiplexed (MDM) and wavelength division multiplexed (WDM) signals is proposed and fabricated. By selectively extracting part of the incoming signals through the tunable wavelength and mode dependent drop filter, the in-line and switchable monitor can discriminate the wavelength, mode and power information of the transmitted signals. Being different from a conventional mode and wavelength demultiplexer, the monitor is specifically designed to ensure a flexible in-line monitoring. For demonstration, three mode and three wavelength multiplexed signals are successfully processed. Assisted by the integrated photodetectors (PDs), both the measured photo currents and eye diagrams validate the performance of the proposed device. The bit error ratio (BER) measurement results show less than 0.4 dB power penalty between different modes and ~2 dB power penalty for single wavelength and WDM cases under 10-9 BER level.
A candidate reference method using ICP-MS for sweat chloride quantification.
Collie, Jake T; Massie, R John; Jones, Oliver A H; Morrison, Paul D; Greaves, Ronda F
2016-04-01
The aim of the study was to develop a method for sweat chloride (Cl) quantification using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to present to the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as a candidate reference method for the diagnosis of cystic fibrosis (CF). Calibration standards were prepared from sodium chloride (NaCl) to cover the expected range of sweat Cl values. Germanium (Ge) and scandium (Sc) were selected as on-line (instrument based) internal standards (IS) and gallium (Ga) as the off-line (sample based) IS. The method was validated through linearity, accuracy and imprecision studies as well as enrolment into the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) for sweat electrolyte testing. Two variations of the ICP-MS method were developed, an on-line and off-line IS, and compared. Linearity was determined up to 225 mmol/L with a limit of quantitation of 7.4 mmol/L. The off-line IS demonstrated increased accuracy through the RCPAQAP performance assessment (CV of 1.9%, bias of 1.5 mmol/L) in comparison to the on-line IS (CV of 8.0%, bias of 3.8 mmol/L). Paired t-tests confirmed no significant differences between sample means of the two IS methods (p=0.53) or from each method against the RCPAQAP target values (p=0.08 and p=0.29). Both on and off-line IS methods generated highly reproducible results and excellent linear comparison to the RCPAQAP target results. ICP-MS is a highly accurate method with a low limit of quantitation for sweat Cl analysis and should be recognised as a candidate reference method for the monitoring and diagnosis of CF. Laboratories that currently practice sweat Cl analysis using ICP-MS should include an off-line IS to help negate any pre-analytical errors.
A multiplex PCR method of detecting recombinant DNAs from five lines of genetically modified maize.
Matsuoka, T; Kuribara, H; Akiyama, H; Miura, H; Goda, Y; Kusakabe, Y; Isshiki, K; Toyoda, M; Hino, A
2001-02-01
Seven lines of genetically modified (GM) maize have been authorized in Japan as foods and feeds imported from the USA. We improved a multiplex PCR method described in the previous report in order to distinguish the five lines of GM maize. Genomic DNA was extracted from GM maize with a silica spin column kit, which could reduce experimental time and improve safety in the laboratory and potentially in the environment. We sequenced recombinant DNA (r-DNA) introduced into GM maize, and re-designed new primer pairs to increase the specificity of PCR to distinguish five lines of GM maize by multiplex PCR. A primer pair for the maize intrinsic zein gene (Ze1) was also designed to confirm the presence of amplifiable maize DNA. The lengths of PCR products using these six primer pairs were different. The Ze1 and the r-DNAs from the five lines of GM maize were qualitatively detected in one tube. The specific PCR bands were distinguishable from each other on the basis of the expected length. The r-DNA could be detected from maize samples containing 0.5% of each of the five lines of GM maize. The sensitivity would be acceptable to secure the verification of non-GMO materials and to monitor the reliability of the labeling system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elvado Environmental LLC
This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2009 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2009 will be in accordance with DOE Order 540.1 requirements and the following goals: (1) to protect the worker, the public, and the environment; (2) to maintain surveillance of existing and potential groundwater contamination sources; (3) to provide for the early detection of groundwater contamination andmore » determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; (4) to identify and characterize long-term trends in groundwater quality at Y-12; and (5) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2009 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation. Modifications to the CY 2009 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2009 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3; sample collection methods and procedures are described in Section 4; and Section 5 lists the documents cited for more detailed operational and technical information.« less
Mwebe, Herbert
2017-10-01
To explore nurses' views of their role in the screening and monitoring of the physical care needs of people with serious mental illness in a mental health service provider. There is increasing awareness through research that people with serious mental illness disproportionately experience and die early from physical health conditions. Mental health nurses are best placed as front-line workers to offer screening, monitoring and interventions; however, their views on physical care interventions are not studied often. Qualitative exploratory study. The study was carried out in a mental health inpatient centre in England. Volunteer sampling was adopted for the study with a total target sample of (n = 20) nurses from three inpatient wards. Semistructured interviews were conducted with (n = 10) registered mental health nurses who had consented to take part in the study. Inductive data analysis and theme development were guided by a thematic analytic framework. Participants shared a clear commitment regarding their role regarding physical health screening and monitoring in mental health settings. Four themes emerged as follows: features of current practice and physical health monitoring; perceived barriers to physical health monitoring; education and training needs; and strategies to improve physical health monitoring. Nurses were unequivocal in their resolve to ensure good standard physical health monitoring and screening interventions in practice. However, identified obstacles have to be addressed to ensure that physical health screening and monitoring is integrated adequately in everyday clinical activities. Achieving this would require improvements in nurses' training, and an integrated multiservice and team-working approach. Attending to the physical health needs of people with serious mental illness has been associated with multiple improvements in both mental and physical health; nurses have a vital role to play in identifying and addressing causes of poor physical health to improve physical health outcomes in people with serious mental illness. © 2016 John Wiley & Sons Ltd.
Drinking water contaminants from epoxy resin-coated pipes: A field study.
Rajasärkkä, Johanna; Pernica, Marek; Kuta, Jan; Lašňák, Jonáš; Šimek, Zdenĕk; Bláha, Luděk
2016-10-15
Rehabilitation of aged drinking water pipes is an extensive renovation and increasingly topical in many European cities. Spray-on-lining of drinking water pipes is an alternative cost-effective rehabilitation technology in which the insides of pipes are relined with organic polymer. A commonly used polymer is epoxy resin consisting of monomer bisphenol A (BPA). Leaching of BPA from epoxy lining to drinking water has been a concern among public and authorities. Currently epoxy lining is not recommended in some countries. BPA leaching has been demonstrated in laboratory studies but the behavior and ageing process of epoxy lining in situ is not well known. In this study 6 locations with different age epoxy linings of drinking water pipes done using two distinct technologies were studied. While bisphenol F, 4-n-nonylphenol, and 4-t-octylphenol were rarely found and in trace concentrations, BPA was detected in majority of samples. Pipes lined with the older technology (LSE) leached more BPA than those with more recent technology (DonPro): maxima in cold water were 0.25 μg/L and 10 ng/L, respectively. Incubation of water in pipes 8-10 h prior to sampling increased BPA concentration in cold water 1.1-43-fold. Hot water temperature caused even more BPA leaching - at maximum 23.5 μg/L. The influence of ageing of epoxy lining on BPA leaching on could be shown in case of LSE technology: locations with 8-9 years old lining leached 4-20-fold more BPA compared to a location with 2-year-old lining. Analysis of metals showed that epoxy lining can reduce especially iron concentration in water. No significant burden to water could be shown by the analyzed 72 volatile organic compounds, including epichlorhydrin, precursor used in epoxy resin. Estrogenicity was detected in water samples with the highest BPA loads. Comparable responses of two yeast bioreporters (estrogen receptor α and BPA-targeted) indicated that bisphenol-like compounds were the main cause of estrogenicity. Compared to the estimated average daily BPA exposure, additional BPA load via cold drinking water in the studied locations was low, maximum 8.7%. However, hot water should also be considered as exposure source due to higher BPA concentrations. Epoxy lined locations should be monitored in future in order to evaluate ageing process and control increasing leaching of potentially harmful chemicals. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Monte Carlo approaches to sampling forested tracts with lines or points
Harry T. Valentine; Jeffrey H. Gove; Timothy G. Gregoire
2001-01-01
Several line- and point-based sampling methods can be employed to estimate the aggregate dimensions of trees standing on a forested tract or pieces of coarse woody debris lying on the forest floor. Line methods include line intersect sampling, horizontal line sampling, and transect relascope sampling; point methods include variable- and fixed-radius plot sampling, and...
Quality assured measurements of animal building emissions: gas concentrations.
Heber, Albert J; Ni, Ji-Qin; Lim, Teng T; Tao, Pei-Chun; Schmidt, Amy M; Koziel, Jacek A; Beasley, David B; Hoff, Steven J; Nicolai, Richard E; Jacobson, Larry D; Zhang, Yuanhui
2006-10-01
Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.
40 CFR 63.605 - Monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) National Emission Standards for Hazardous Air Pollutants From Phosphoric Acid Manufacturing Plants § 63.605 Monitoring requirements. (a)(1) Each owner or operator of a new or existing wet-process phosphoric acid process line or superphosphoric acid process line subject to the provisions of this subpart shall install...
Monitor Variability of Millimeter Lines in IRC+10216
NASA Astrophysics Data System (ADS)
He, J. H.; Dinh-V-Trung; Hasegawa, T. I.
2017-08-01
A single dish monitoring of millimeter maser lines SiS J = 14-13 and HCN {ν }2={1}f J = 3-2 and several other rotational lines is reported for the archetypal carbon star IRC+10216. Relative line strength variations of 5% ∼ 30% are found for eight molecular line features with respect to selected reference lines. Definite line-shape variations are found in limited velocity intervals of the SiS and HCN line profiles. The asymmetrical line profiles of the two lines are mainly due to the varying components. The dominant varying components of the line profiles have similar periods and phases to the IR light variation, though both quantities show some degree of velocity dependence; there is also variability asymmetry between the blue and red line wings of both lines. Combining the velocities and amplitudes with a wind velocity model, we suggest that the line profile variations are due to SiS and HCN masing lines emanating from the wind acceleration zone. The possible link of the variabilities to thermal, dynamical, and/or chemical processes within or under this region is also discussed.
NASA Astrophysics Data System (ADS)
Barron, Keiron Robert Philip
Available from UMI in association with The British Library. The need to monitor corrosion products in the primary circuit of a pressurised water reactor (PWR), at a concentration of 10pg ml^{-1} is discussed. A review of trace and ultra-trace metal analysis, relevant to the specific requirements imposed by primary coolant chemistry, indicated that high performance liquid chromatography (HPLC), coupled with preconcentration of sample was an ideal technique. A HPLC system was developed to determine trace metal species in simulated PWR primary coolant. In order to achieve the desired detection limit an on-line preconcentration system had to be developed. Separations were performed on Aminex A9 and Benson BC-X10 analytical columns. Detection was by post column reaction with Eriochrome Black T and Calmagite Linear calibrations of 2.5-100ng of cobalt (the main species of interest), were achieved using up to 200ml samples. The detection limit for a 200ml sample was 10pg ml^{-1}. In order to achieve the desired aim of on-line collection of species at 300^circ C, the use of inorganic ion-exchangers is essential. A novel application, utilising the attractive features of the inorganic ion-exchangers titanium dioxide, zirconium dioxide, zirconium arsenophosphate and pore controlled glass beads, was developed for the preconcentration of trace metal species at temperature and pressure. The performance of these exchangers, at ambient and 300^ circC was assessed by their inclusion in the developed analytical system and by the use of radioisotopes. The particular emphasis during the development has been upon accuracy, reproducibility of recovery, stability of reagents and system contamination, studied by the use of radioisotopes and response to post column reagents. This study in conjunction with work carried out at Winfrith, resulted in a monitoring system that could follow changes in coolant chemistry, on deposition and release of metal species in simulated PWR water loops. On -line detection of cobalt at 11pg ml^{ -1} was recorded, something which previously could not be performed by other techniques.
Jang, Jae-Kil; Shin, Jung-Ah
2011-01-01
Objectives This study was designed to evaluate exposure levels of various chemicals used in wafer fabrication product lines in the semiconductor industry where work-related leukemia has occurred. Methods The research focused on 9 representative wafer fabrication bays among a total of 25 bays in a semiconductor product line. We monitored the chemical substances categorized as human carcinogens with respect to leukemia as well as harmful chemicals used in the bays and substances with hematologic and reproductive toxicities to evaluate the overall health effect for semiconductor industry workers. With respect to monitoring, active and passive sampling techniques were introduced. Eight-hour long-term and 15-minute short-term sampling was conducted for the area as well as on personal samples. Results The results of the measurements for each substance showed that benzene, toluene, xylene, n-butyl acetate, 2-methoxyethanol, 2-heptanone, ethylene glycol, sulfuric acid, and phosphoric acid were non-detectable (ND) in all samples. Arsine was either "ND" or it existed only in trace form in the bay air. The maximum exposure concentration of fluorides was approximately 0.17% of the Korea occupational exposure limits, with hydrofluoric acid at about 0.2%, hydrochloric acid 0.06%, nitric acid 0.05%, isopropyl alcohol 0.4%, and phosphine at about 2%. The maximum exposure concentration of propylene glycol monomethyl ether acetate (PGMEA) was 0.0870 ppm, representing only 0.1% or less than the American Industrial Hygiene Association recommended standard (100 ppm). Conclusion Benzene, a known human carcinogen for leukemia, and arsine, a hematologic toxin, were not detected in wafer fabrication sites in this study. Among reproductive toxic substances, n-butyl acetate was not detected, but fluorides and PGMEA existed in small amounts in the air. This investigation was focused on the air-borne chemical concentrations only in regular working conditions. Unconditional exposures during spills and/or maintenance tasks and by-product chemicals were not included. Supplementary studies might be required. PMID:22953186
Lee, Sang Tak; Yang, Boram; Kim, Jin-Yong; Park, Ji-Hyung; Moon, Myeong Hee
2015-08-28
This study demonstrated that asymmetrical flow field-flow fractionation (AF4) coupled with on-line UV and fluorescence detection (FLD) and off-line excitation-emission matrix (EEM) fluorescence spectroscopy can be employed to analyze the influence of microbial metabolic activity on the consumption and production of freshwater organic matter. With the AF4 system, organic matter is on-line enriched during a focusing/relaxation period, which is an essential process prior to separation. Size-fractionated chromophoric and fluorophoric organic materials were simultaneously monitored during the 30-min AF4 separation process. Two fractions of different sizes (dissolved organic matter (DOM) and particulate organic matter (POM)) of freshwater samples from three locations (up-, mid-, and downstream) along the Han River basin of Korea were incubated with the same inoculum for 14 days to analyze fraction-specific alterations in optical properties using AF4-UV-FLD. A comparison of AF4 fractograms obtained from pre- and post-incubation samples revealed that POM-derived DOM were more susceptible to microbial metabolic activity than was DOM. Preferential microbial consumption of protein-like DOM components concurred with enhanced peaks of chromophoric and humic-like fluorescent components, presumably formed as by-products of microbial processing. AF4-UV-FLD combined with off-line identification of microbially processed components using EEM fluorescence spectroscopy provides a powerful tool to study the relationship between microbial activity and composition as well as biodegradability of DOM and POM-derived DOM from different origins, especially for the analysis of chromophoric and fluorophoric organic matter that are consumed and produced by microbial metabolic activity. The proposed AF4 system can be applied to organic matter in freshwater samples having low concentration range (0.3-2.5ppm of total organic carbon) without a pre-concentration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.
Kanawade, Rajesh; Mahari, Fanuel; Klämpfl, Florian; Rohde, Maximilian; Knipfer, Christian; Tangermann-Gerk, Katja; Adler, Werner; Schmidt, Michael; Stelzle, Florian
2015-01-01
The research work presented in this paper focuses on qualitative tissue differentiation by monitoring the intensity ratios of atomic emissions using 'Laser Induced Breakdown Spectroscopy' (LIBS) on the plasma plume created during laser tissue ablation. The background of this study is to establish a real time feedback control mechanism for clinical laser surgery systems during the laser ablation process. Ex-vivo domestic pig tissue samples (muscle, fat, nerve and skin) were used in this experiment. Atomic emission intensity ratios were analyzed to find a characteristic spectral line for each tissue. The results showed characteristic elemental emission intensity ratios for the respective tissues. The spectral lines and intensity ratios of these specific elements varied among the different tissue types. The main goal of this study is to qualitatively and precisely identify different tissue types for tissue specific laser surgery. © 2015 The Authors. Journal of Biophotonics published by WILEY-VCH Verlag.
Liang, Qiangbing; Yang, Baodong; Zhang, Tiancai; Wang, Junmin
2010-06-21
By monitoring the transmission of probe laser beam (also served as coupling laser beam) which is locked to a cycling hyperfine transition of cesium D(2) line, while pumping laser is scanned across cesium D(1) or D(2) lines, the single-resonance optical pumping (SROP) spectra are obtained with atomic vapor cell. The SROP spectra indicate the variation of the zero-velocity atoms population of one hyperfine fold of ground state, which is optically pumped into another hyperfine fold of ground state by pumping laser. With the virtue of Doppler-free linewidth, high signal-to-noise ratio (SNR), flat background and elimination of crossover resonance lines (CRLs), the SROP spectra with atomic vapor cell around room temperature can be employed to measure dressed-state splitting of ground state, which is normally detected with laser-cooled atomic sample only, even if the dressed-state splitting is much smaller than the Doppler-broaden linewidth at room temperature.
Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.
2016-02-01
Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis ofmore » single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.
Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis ofmore » single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.« less
HYDROBS: a long-term autonomous mooring for passive acoustic monitoring
NASA Astrophysics Data System (ADS)
Hello, Y.; Royer, J. Y.; Yegikyan, M.
2017-12-01
Passive acoustics proves an effective way for monitoring the low-level seismic activity of the ocean floor and low-frequency sounds from the ocean (baleen whales, sea-state, icebergs). Networks of synchronized autonomous hydrophones have thus been commonly deployed in the world ocean to monitor large sections of mid-oceanic ridges. HYDROBS is an improved system that meet two requirements: an easy access to the data collected by the instruments together with long-term deployments - up to 4 consecutive years - reducing the need of large vessels capable of yearly mooring operations in open seas. The system has two components: a data logger, up-to-date but similar to previous systems, and three messengers, releasable on demand to collect the data. The mooring line itself is classical, with an expandable weight at the sea-bottom to maintain the mooring, an acoustic release to free the mooring line for recovery, a line adjustable to the seafloor depth, and an immerged buoy, holding the acquisition system, to maintain the sensors at a constant depth and to bring the mooring line to the surface for its recovery. The data logger is based on a low-power microprocessor, an A/D-32bit convertor sampling at 250Hz, a 10-8 real time clock and SD card storage. Lithium batteries provide 3-4 years of autonomy. Acoustic communications with the surface-ship provide control over all functionalities at deployment and a health bulletin on demand. The 3 shuttles, encapsulated in 13" glass spheres, use the same CPU board and clock as the main station. Data transfer from the data logger to the shuttles is wireless (1Mbit/s digital inductive through water). Data are duplicated once per day on shuttles N and N+1 for redundancy. Prior to their release by acoustic command, the shuttles are synchronized with the master clock. At sea-surface, shuttles (as the main unit) look for GPS time and calculate their clock drift. So, the master clock drift can be monitored over time at every shuttle release until its final recovery. Shuttles and main unit are located on the sea-surface by AIS. Iridium communications can also be set to warn the user of a false release. A non-specialist can thus easily handle a shuttle recovery from a ship of opportunity. With 4-channels, this system is also suitable to monitor other parameters in the water column, continuously and over long periods.
DEPLOYMENT OF A WATER QUALITY EARLY WARNING SYSTEM USING ON-LINE TOXICITY MONITORS
Contaminants are of concern when they are found in concentrations that are toxic to plants and/or animals. On–line Toxicity Monitors (OTMs) integrate all factors resulting in stress including physical and chemical qualities. This is important because of the limitations of c...
Kögler, Martin; Paul, Andrea; Anane, Emmanuel; Birkholz, Mario; Bunker, Alex; Viitala, Tapani; Maiwald, Michael; Junne, Stefan; Neubauer, Peter
2018-06-08
The application of Raman spectroscopy as a monitoring technique for bioprocesses is severely limited by a large background signal originating from fluorescing compounds in the culture media. Here we compare time-gated Raman (TG-Raman)-, continuous wave NIR-process Raman (NIR-Raman) and continuous wave micro-Raman (micro-Raman) approaches in combination with surface enhanced Raman spectroscopy (SERS) for their potential to overcome this limit. For that purpose, we monitored metabolite concentrations of Escherichia coli bioreactor cultivations in cell-free supernatant samples. We investigated concentration transients of glucose, acetate, AMP and cAMP at alternating substrate availability, from deficiency to excess. Raman and SERS signals were compared to off-line metabolite analysis of carbohydrates, carboxylic acids and nucleotides. Results demonstrate that SERS, in almost all cases, led to a higher number of identifiable signals and better resolved spectra. Spectra derived from the TG-Raman were comparable to those of micro-Raman resulting in well-discernable Raman peaks, which allowed for the identification of a higher number of compounds. In contrast, NIR-Raman provided a superior performance for the quantitative evaluation of analytes, both with and without SERS nanoparticles when using multivariate data analysis. This article is protected by copyright. All rights reserved. © 2018 American Institute of Chemical Engineers.
Mentana, Annalisa; Palermo, Carmen; Nardiello, Donatella; Quinto, Maurizio; Centonze, Diego
2013-01-09
In this work the optimization and application of a dual-amperometric biosensor for simultaneous monitoring of glucose and ethanol content, as quality markers in drinks and alcoholic fermentation media, are described. The biosensor is based on glucose oxidase (GOD) and alcohol oxidase (AOD) immobilized by co-cross-linking with bovine serum albumin (BSA) and glutaraldehyde (GLU) both onto a dual gold electrode, modified with a permselective overoxidized polypyrrole film (PPYox). Response, rejection of interferents, and stability of the dual biosensor were optimized in terms of PPYox thickness, BSA, and enzyme loading. The biosensor was integrated in a flow injection system coupled with an at-line microdialysis fiber as a sampling tool. Flow rates inside and outside the fiber were optimized in terms of linear responses (0.01-1 and 0.01-1.5 M) and sensitivities (27.6 ± 0.4 and 31.0 ± 0.6 μA·M(-1)·cm(-2)) for glucose and ethanol. Excellent anti-interference characteristics, the total absence of "cross-talk", and good response stability under operational conditions allowed application of the dual biosensor in accurate real-time monitoring (at least 15 samples/h) of alcoholic drinks, white grape must, and woody biomass.
Chiereghin, A; Prete, A; Belotti, T; Gibertoni, D; Piccirilli, G; Gabrielli, L; Pession, A; Lazzarotto, T
2016-02-01
In 28 pediatric allogeneic hematopoietic stem cell transplant (allo-HSCT) recipients, we aimed to evaluate: (i) the impact of routine Epstein-Barr virus (EBV) DNA monitoring on the development of EBV-related post-transplant lymphoproliferative disorder (EBV-PTLD); (ii) the incidence of EBV infection and the potential risk factors; and (iii) the suitability of whole blood (WB) as clinical specimen to monitor the risk of patients to develop EBV-PTLD. Quantitative real-time polymerase chain reaction assay was performed on WB samples for all patients. EBV DNA quantification also in peripheral blood mononuclear cells (PBMCs) samples was adopted for the patients at higher risk of developing EBV-PTLD (≥ 10,000 copies/mL WB). High EBV DNAemia levels were observed in 37.5% of the actively infected recipients (57.1%). Severe aplastic anemia, matched-unrelated donor transplant, the reduced-intensity conditioning regimen and, to a lesser extent, the in vivo T-cell depletion with anti-thymocyte immunoglobulin were associated with high viral load. A significant correlation between EBV DNA levels in WB and PBMC samples was obtained (r = 0.755, P < 0.001). A similar kinetics of EBV DNA in the 2 blood compartments was observed. Clinically, both specimen types appeared to be equally informative to assess the risk of patients to develop PTLD. On the basis of EBV DNAemia levels, in 3 patients (10.7%) immunosuppressive therapy was reduced and 1 patient (3.5%) received early treatment for probable EBV disease. No patients developed EBV-PTLD. WB proved to be a suitable clinical specimen to monitor EBV DNA load after allo-HSCT for the management of EBV infection and PTLD prevention. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Measurement of diabetic sugar concentration in human blood using Raman spectroscopy
NASA Astrophysics Data System (ADS)
Firdous, S.; Nawaz, M.; Ahmed, M.; Anwar, S.; Rehman, A.; Rashid, R.; Mahmood, A.
2012-06-01
This study demonstrates the use of Raman spectroscopy for the direct measurement of diabetic sugar in human blood using 532 nm laser system. Raman spectra were collected from whole blood drawn from 21 individuals. We have elicited a reliable glucose signature in diabetic patients, and measured glucose levels in blood serum of normal, healthy diabetic and diabetic patients with other malignancies like cancer and hepatitis. Quantitative predictions of glucose spectra illustrate the predictions based on molecular information carried by the Raman light in highly light-scattering and absorbing media. Raman spectrum peaks for diabetic blood serum are observed at 1168, 1531, 1463, 1021 cm-1 with intensity level 17000 to 18500 pixels attributed to carbohydrates, proteins, lipids, collagen, and skeletal C-C stretch of lipids acyl chains. Raman spectra for normal, diabetic patients having cancer and hepatitis were also recorded. This in vitro glucose monitoring methodology will lead in vivo noninvasive on-line monitoring having painless and at the same time the data will be displayed on-line and in real time. The measured Raman peaks provides detailed bio-chemical fingerprint of the sample and could confer diagnostic benefit in a clinical setting.
Light scattering application for quantitative estimation of apoptosis
NASA Astrophysics Data System (ADS)
Bilyy, Rostyslav O.; Stoika, Rostyslav S.; Getman, Vasyl B.; Bilyi, Olexander I.
2004-05-01
Estimation of cell proliferation and apoptosis are in focus of instrumental methods used in modern biomedical sciences. Present study concerns monitoring of functional state of cells, specifically the development of their programmed death or apoptosis. The available methods for such purpose are either very expensive, or require time-consuming operations. Their specificity and sensitivity are frequently not sufficient for making conclusions which could be used in diagnostics or treatment monitoring. We propose a novel method for apoptosis measurement based on quantitative determination of cellular functional state taking into account their physical characteristics. This method uses the patented device -- laser microparticle analyser PRM-6 -- for analyzing light scattering by the microparticles, including cells. The method gives an opportunity for quick, quantitative, simple (without complicated preliminary cell processing) and relatively cheap measurement of apoptosis in cellular population. The elaborated method was used for studying apoptosis expression in murine leukemia cells of L1210 line and human lymphoblastic leukemia cells of K562 line. The results obtained by the proposed method permitted measuring cell number in tested sample, detecting and quantitative characterization of functional state of cells, particularly measuring the ratio of the apoptotic cells in suspension.
Noise Reduction and Correction in the IPNS Linac ESEM
NASA Astrophysics Data System (ADS)
Dooling, J. C.; Brumwell, F. R.; Donley, L.; McMichael, G. E.; Stipp, V. F.
2004-11-01
The Energy Spread and Energy Monitor (ESEM) is an on-line, non-intrusive diagnostic used to characterize the output beam from the 200-MHz, 50-MeV IPNS linac. The energy spread is determined from a 3-size, longitudinal emittance measurement; whereas the energy is derived from time of flight (TOF) analysis. Signals are detected on 50-ohm, stripline beam position monitors (BPMs) terminated in their characteristic impedance. Each BPM is constructed with four striplines: top, bottom, left and right. The ESEM signals are taken from the bottom stripline in four separate BPM locations in the 50-MeV transport line between the linac and the synchrotron. Deterministic linac noise is sampled before and after the 70-microsecond macropulse. The noise phasor is vectorially subtracted from the beam signal. Noise subtraction is required at several frequencies, especially the fundamental and fifth harmonics (200 MHz and 1 GHz). It is also necessary to correct for attenuation and dispersion in the co-axial signal cables. Presently, the analysis assumes a single particle distribution to determine energy and energy spread. Work is on-going to allow for more realistic longitudinal distributions to be included in the analysis.
Li, B; Zhang, Z; Liu, W
2001-05-30
A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elvado Environmental LLC for the Environmental Compliance Department ES&H Division, Y-12 National Security Complex Oak Ridge, Tennessee
2003-09-30
This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2004 at the U.S. Department of Energy (DOE) Y-12 National Security Complex that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2004 will be in accordance with the following requirements of DOE Order 5400.1: (1) to maintain surveillance of existing and potential groundwater contamination sources; (2) to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are mostmore » likely to migrate beyond the Oak Ridge Reservation property line; (3) to identify and characterize long-term trends in groundwater quality at Y-12; and (4) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2004 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation (Figure A.1). Modifications to the CY 2004 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells, or wells could be added or removed from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2004-09-30
This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2005 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2005 will be in accordance with DOE Order 540.1 requirements and the following goals: (1) to maintain surveillance of existing and potential groundwater contamination sources; (2) to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminantsmore » are most likely to migrate beyond the Oak Ridge Reservation property line; (3) to identify and characterize long-term trends in groundwater quality at Y-12; and (4) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2005 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation (Figure A.1). Modifications to the CY 2005 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan.« less
Yang, Xin-an; Zhang, Wang-bing
2013-01-01
A simple and green flow injection chemiluminescence (FI-CL) method for determination of the fungicide azoxystrobin was described for the first time. CL signal was generated when azoxystrobin was injected into a mixed stream of luminol and KMnO4 . The CL signal of azoxystrobin could be greatly improved when an off-line ultrasonic treatment was adopted. Meanwhile, the signal intensity increases with the analyte concentration proportionally. Several variables, such as the ultrasonic parameters, flow rate of reagents, concentrations of sodium hydroxide solution and CL reagents (potassium permanganate, luminol) were investigated, and the optimal CL conditions were obtained. Under optimal conditions, the linear range of 1-100 ng/mL for azoxystrobin was obtained and the detection limit (3σ) was determined as 0.13 ng/mL. The relative standard deviation was 1.5% for 10 consecutive measurements of 20 ng/mL azoxystrobin. The method has been applied to the determination of azoxystrobin residues in water samples. Copyright © 2012 John Wiley & Sons, Ltd.
Surface treatment of alumina-based ceramics using combined laser sources
NASA Astrophysics Data System (ADS)
Triantafyllidis, D.; Li, L.; Stott, F. H.
2002-01-01
Alumina-based refractory materials are extensively used as linings in incinerators and furnaces. These materials are subject to molten salt corrosion and chemical degradation because of the existence of porosity and material inhomogeneity. Efforts to improve the performance of these materials have so far concentrated mainly on the optimisation of the manufacturing processes (e.g. producing denser refractory bricks) and in-service monitoring. Laser surface treatment has also been used to improve performance. The main problem identified with laser surface treatment is solidification cracking due to the generation of very large temperature gradients. The aim of this paper is to investigate the surface modification of alumina-based ceramics by using two combined laser sources in order to control the thermal gradients and cooling rates during processing so that crack formation can be eliminated. The material under investigation is 85% alumina refractory ceramic, used as lining material in incineration plants. The surface morphology and cross-section of the treated samples are analysed using optical and scanning electron microscopy (SEM) and compared with single laser beam treated samples.
Monitoring Ecological Impacts of Environmental Surface ...
Optimized cell-based metabolomics has been used to study the impacts of contaminants in surface waters on human and fish metabolomes. This method has proven to be resource- and time-effective, as well as sustainable for long term and large scale studies. In the current study, cell-based metabolomics is used to investigate the impacts of contaminants in surface waters on biological pathways in human and ecologically relevant cell lines. Water samples were collected from stream sites nationwide, where significant impacts have been estimated from the most potentially contaminated sources (i.e. waste water treatment plants, concentrated animal feeding operations, mining operations, and plant-based agricultural operations that use intensive chemical applications). Zebrafish liver cells (ZFL) were used to study exposure impacts on in vitro metabolomes. In addition, a small number of water samples were studied using two human cell lines (liver cells, HepG2 and brain cells, LN229). The cellular metabolites were profiled by nuclear magnetic resonance (NMR) spectroscopy and gas chromatography mass spectrometry (GC-MS). Detailed methods and results will be reported. Presented at SETAC North America 37th Annual Meeting
NASA Astrophysics Data System (ADS)
Wang, Xinyi; Shen, Jialong; Liu, Xinbo
2018-01-01
Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.
Parental monitoring may protect impulsive children from overeating.
Bennett, C; Blissett, J
2017-10-01
Research has highlighted links between impulsivity and weight in children and adults. Nevertheless, little is known about the nature of this link in very young children or about the underlying mechanism by which impulsivity leads to greater adiposity. The present study aimed to explore relationships between impulsivity, weight and eating behaviour in a sample of 95 2 to 4-year-olds. Parent-child dyads visited the laboratory and consumed a meal after which parents completed measures of child impulsivity, eating behaviour and parental feeding, whilst children completed impulsivity tasks measuring the impulsivity facet delay of gratification (Snack Delay task), motor impulsivity (Line Walking task) and inhibitory control (Tower task). Pearson's correlations showed that girls with greater motor impulsivity were heavier. Additionally, monitoring moderated the relationship between impulsivity and food approach behaviour, indicating that monitoring may protect more impulsive children from displaying problematic eating behaviours. The motor impulsivity facet appears particularly relevant to child weight; parents can modulate the impact of impulsivity on child eating behaviour through their feeding style. © 2016 World Obesity Federation.
NASA Technical Reports Server (NTRS)
Burlage, Robert S.; Heitzer, Armin; Digrazia, Philip M.
1991-01-01
An effective on-line monitoring technique for toxic waste bioremediation using bioluminescent microorganisms has shown great potential for the description and optimization of biological processes. The lux genes of the bacterium Vibrio fischeri are used by this species to produce visible light. The lux genes can be genetically fused to the control region of a catabolic gene, with the result that bioluminescence is produced whenever the catabolic gene is induced. Thus the detection of light from a sample indicates that genetic expression from a specific gene is occurring. This technique was used to monitor biodegradation of specific contaminants from waste sites. For these studies, fusions between the lux genes and the operons for naphthalene and toluene/xylene degradation were constructed. Strains carrying one of these fusions respond sensitively and specifically to target substrates. Bioluminescence from these cultures can be rapidly measured in a nondestructive and noninvasive manner. The potential for this technique in this and other biological systems is discussed.
Fusion peptides from oncogenic chimeric proteins as putative specific biomarkers of cancer.
Conlon, Kevin P; Basrur, Venkatesha; Rolland, Delphine; Wolfe, Thomas; Nesvizhskii, Alexey I; MacCoss, Michael J; Lim, Megan S; Elenitoba-Johnson, Kojo S J
2013-10-01
Chromosomal translocations encoding chimeric fusion proteins constitute one of the most common mechanisms underlying oncogenic transformation in human cancer. Fusion peptides resulting from such oncogenic chimeric fusions, though unique to specific cancer subtypes, are unexplored as cancer biomarkers. Here we show, using an approach termed fusion peptide multiple reaction monitoring mass spectrometry, the direct identification of different cancer-specific fusion peptides arising from protein chimeras that are generated from the juxtaposition of heterologous genes fused by recurrent chromosomal translocations. Using fusion peptide multiple reaction monitoring mass spectrometry in a clinically relevant scenario, we demonstrate the specific, sensitive, and unambiguous detection of a specific diagnostic fusion peptide in clinical samples of anaplastic large cell lymphoma, but not in a diverse array of benign lymph nodes or other forms of primary malignant lymphomas and cancer-derived cell lines. Our studies highlight the utility of fusion peptides as cancer biomarkers and carry broad implications for the use of protein biomarkers in cancer detection and monitoring.
NASA Astrophysics Data System (ADS)
Guenther, Hans; Brickhouse, N. S.; Dupree, A. K.; Luna, G.; Schneider, P. C.; Wolk, S. J.
2014-01-01
Classical T Tauri stars (CTTS) show strong, broad and asymmetric FUV emission lines. Neither the width, nor the line profile is understood. Likely, different mechanisms influence the line profile; the best candidates are accretion, winds and stellar activity. We monitored the C IV 1548/1550 Å doublet in the nearby, bright CTTS TW Hya to correlate it with i) the cool wind, as seen in COS NUV Mg II line profiles, ii) the photometric period from joint ground-based monitoring, iii) the accretion rate as determined from the UV continuum and iv) the Ha line profile from independent ground-based observations. The observations span 10 orbits distributed over a few weeks to cover the typical time scales of stellar rotation, accretion and winds. On short time scales (seconds) the variability in the data is compatible with counting statistics when we take certain instrumental effects (the detector dead-time fraction increases when the wavelength calibration lamps are switched on). This rules out any type of coherent accretion shock fluctuation as predicted in some simulations. On longer time scales (days) variability of a factor of 3 in the continuum and similarly massive changes in the line shape are seen. The ratio of the two lines of the doublet indicates that the lines are optically thick, calling into question the idea that the blue-shifted components of the C IV lines are formed in the pre-shock region.
NASA Astrophysics Data System (ADS)
Jules, Kenol; Lin, Paul P.
2007-06-01
With the International Space Station currently operational, a significant amount of acceleration data is being down-linked, processed and analyzed daily on the ground on a continuous basis for the space station reduced gravity environment characterization, the vehicle design requirements verification and science data collection. To help understand the impact of the unique spacecraft environment on the science data, an artificial intelligence monitoring system was developed, which detects in near real time any change in the reduced gravity environment susceptible to affect the on-going experiments. Using a dynamic graphical display, the monitoring system allows science teams, at any time and any location, to see the active vibration disturbances, such as pumps, fans, compressor, crew exercise, re-boost and extra-vehicular activities that might impact the reduced gravity environment the experiments are exposed to. The monitoring system can detect both known and unknown vibratory disturbance activities. It can also perform trend analysis and prediction by analyzing past data over many increments (an increment usually lasts 6 months) collected onboard the station for selected disturbances. This feature can be used to monitor the health of onboard mechanical systems to detect and prevent potential systems failures. The monitoring system has two operating modes: online and offline. Both near real-time on-line vibratory disturbance detection and off-line detection and trend analysis are discussed in this paper.
NASA Technical Reports Server (NTRS)
1994-01-01
The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.
Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.
Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R
1994-12-01
LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.
Development and Application of On-line Monitor for the ZLW-1 Axis Cracks
NASA Astrophysics Data System (ADS)
Shi-jun, Yang; Qian-hui, Yang; Jian-guo, Jin
2018-03-01
This article mainly introduces a method that uses acoustic emission techniques to achieve on-line monitor for the shaft cracks and crack growth. According to this method, axis crack monitor is produced by acoustic emission techniques. This instrument can apply to all the pressure vessels, pipelines and rotor machines that can bear buckling load. It has the online real-time monitoring, automatic recording, printing, sound and light alarm, collecting crack information function. After a series of tests in both laboratory and field, it shows that this instrument is very versatile and possesses broad prospects of development and application.
Bechy-Loizeau, Anne-Laure; Flandrois, Jean-Pierre; Abaibou, Hafid
2015-07-01
On the ISS, as on Earth, water is an essential element for life and its quality control on a regular basis allows to ensure the health of the crew and the integrity of equipment. Currently, microbial water analysis onboard ISS still relies on the traditional culture-based microbiology methods. Molecular methods based on the amplification of nucleic acids for microbiological analysis of water quality show enormous potential and are considered as the best alternative to culture-based methods. For this reason, the Midass, a fully integrated and automated prototype was designed conjointly by ESA and bioMérieux for a rapid monitoring of the microbiological quality of air. The prototype allows air sampling, sample processing and the amplification/detection of nucleic acids. We describe herein the proof of principle of an analytical approach based on molecular biology that could fulfill the ESA's need for a rapid monitoring of the microbiological quality of recycled water onboard ISS. Both concentration and recovery of microorganisms are the main critical steps when the microfiltration technology is used for water analysis. Among filters recommended standards for monitoring the microbiological quality of the water, the polycarbonate filter was fully in line with the requirements of the ISO 7704-1985 standard in terms of efficacy of capture and recovery of bacteria. Moreover, this filter does not retain nucleic acids on the surface and has no inhibitory effect on their downstream processing steps such as purification and amplification/detection. Although the Midass system was designed for the treatment of air samples, the first results on the integration of PC filters were encouraging. Nevertheless, system modifications are needed to better adapt the Midass system for the monitoring of the microbiological water quality. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
40 CFR 60.103a - Design, equipment, work practice or operational standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Description and simple process flow diagram showing the interconnection of the following components of the... rate. (iv) Description and simple process flow diagram showing all gas lines (including flare, purge... which lines are monitored and identify on the process flow diagram the location and type of each monitor...
40 CFR 60.103a - Design, equipment, work practice or operational standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Description and simple process flow diagram showing the interconnection of the following components of the... rate. (iv) Description and simple process flow diagram showing all gas lines (including flare, purge... which lines are monitored and identify on the process flow diagram the location and type of each monitor...
What do we know about Indonesian tropical lakes? Insights from high frequency measurement
NASA Astrophysics Data System (ADS)
Budi Santoso, Arianto; Triwisesa, Endra; Fakhrudin, Muh.; Harsono, Eko; Agita Rustini, Hadiid
2018-02-01
When measuring ecological variables in lakes, sampling frequency is critical in capturing an environmental pattern. Discrete sampling of traditional monitoring programs is likely to result in vital knowledge gaps in understanding any processes particularly those with fine temporal scale characteristics. The development of high frequency measurements offer a sophisticated range of information in recording any events in lakes at a finer time scale. We present physical indices of a tropical deep Lake Maninjau arrayed from OnLine Monitoring System (OLM). It is revealed that Lake Maninjau mostly has a diurnal thermal stratification pattern. The calculated lake stability (Schmidt stability), however, follows a seasonal pattern; low in December-January and around August, and high in May and September. Using a 3D numerical model simulation (ELCOM), we infer how wind and solar radiation intensity control lake’s temperature profiles. In this review, we highlight the needs of high frequency measurement establishment in Indonesian tropical lakes to better understand the unique processes and to support the authorities’ decision making in maximizing the provision of ecosystem services supplied by lakes and reservoirs.
Orbital surveys of solar stimulated luminescence
NASA Astrophysics Data System (ADS)
Hemphill, W. R.; Theisen, A. F.; Tyson, R. M.; Granata, J. S.
The Fraunhofer line discriminator (FLD) is an electro-optical device for imaging natural and manmade materials which have been stimulated to luminesce by the sun. An airborne FLD has been used to detect geochemically stressed vegetation, drought-stressed agricultural crops, industrial and residential pollution effluents, marine oil seeps, phosphate rock, uranium-bearing sandstone, and bioluminescent ocean plankton. Three-dimensional perspective plots of excitation and emission spectra, measured with a laboratory spectrometer, graphically depict similarities and differences in luminescence properties between sample materials. The laboratory data also include luminescence intensities at six Fraunhofer lines in the visible and near-infrared regions of the electromagnetic spectrum. Both the airborne and laboratory data suggest the feasibility of delineating and monitoring at least some of these luminescing materials from orbital altitude, such as a test flight aboard the Space Shuttle using an improved third-generation FLD.
An electrical sensor for long-term monitoring of ultrafine particles in workplaces
NASA Astrophysics Data System (ADS)
Lanki, Timo; Tikkanen, Juha; Janka, Kauko; Taimisto, Pekka; Lehtimäki, Matti
2011-07-01
Pegasor Oy Ltd. (Finland) has developed a diffusion charging measurement device that enables continuous monitoring of fine particle concentration at a low initial and lifecycle cost. The innovation, for which an international process and apparatus patent has been applied for, opens doors for monitoring nanoparticle concentrations in workplaces. The Pegasor Particle Sensor (PPS) operates by electrostatically charging particles passing through the sensor and then measuring the current caused by the charged particles as they leave the sensor. The particles never touch the sensor and so never accumulate on its surfaces or need to be cleaned off. The sensor uses an ejector pump to draw a constant sample flow into the sensing area where it is mixed with the clean, charged pump flow air (provided by an external source). The sample flow containing charged particles passes through the sensor. The current generated by the charge leaving the detection volume is measured and related to the particle surface area. This system is extremely simple and reliable - no contact, no moving parts, and all critical parts of the sensor are constantly cleaned by a stream of fresh, filtered air. Due to the ejector pump, the sample flow, and respectively the sensor response is independent of the flow and pressure conditions around the sampling inlet. Tests with the Pegasor Particle Sensor have been conducted in a laboratory, and at a workplace producing nanoparticles for glass coatings. A new measurement protocol has been designed to ensure that process workers are not exposed to unusually high nanoparticle concentrations at any time during their working day. One sensor is placed inside the process line, and a light alarm system indicates the worker not to open any protective shielding or ventilation systems before concentration inside has reached background levels. The benefits of PPS in industrial hygiene are that the same monitoring technology can be used at the source as well as at the worker breathing zone. Up to eight sensors can be installed in series for centralized monitoring of the whole process in real time.
Current and future management of treatment failure in low- and middle-income countries.
Boyd, Mark A
2010-01-01
Access to second-line therapy in low- and middle-income countries has been limited to date. The WHO predicts that between 500 000 and 800 000 HIV-infected people on first-line combination antiretroviral therapy will require switch to second-line therapy by 2010. This paper aims to describe and review access to second-line therapy in low- and middle-income countries at present and examine future possibilities. The majority of HIV-infected patients failing first-line combination antiretroviral therapy is identified by way of routine monitoring of clinical and immunological status as a surrogate for virological monitoring. Evidence suggests that immunological and clinical monitoring lack both sensitivity and specificity for virological failure. Consequently, at treatment failure, patients have often selected a degree of resistance within the nucleoside/nucleotide reverse transcriptase inhibitor class that questions the efficacy of using nucleoside/nucleotide reverse transcriptase inhibitors in a second-line regimen. There is a paucity of good-quality evidence on which to base guidelines and policy. Optimally, a second-line regimen would be simple, potent, tolerable and lend itself to provision according to the successful 'public health' approach. Provision of second-line therapy to HIV-infected individuals failing first-line therapy is a major challenge to the ongoing success of access to HIV care programmes in low- and middle-income countries. The optimal second-line combination antiretroviral therapies are unknown. Research trials to help define best practice are in advanced stages of development and implementation.
NASA Astrophysics Data System (ADS)
Höbel, M.; Haffner, K.
1999-05-01
Instrumentation that allows the behaviour of a hydro-generator thrust bearing to be monitored during operation is described. The measurement system was developed at the Asea Brown Boveri corporate research centre in Switzerland and was tested under realistic operating conditions at the Harbin Electric Machinery Company bearing-testing facility in the People's Republic of China. Newly developed fibre-optical proximity probes were used for the on-line monitoring of the thin oil film between the static and rotating parts of the bearing. These sensors are based on a back-reflection technique and can be used for various target materials such as Babbitt and Teflon. The monitoring system comprises about 120 temperature sensors, four pressure sensors and five optical oil-film thickness sensors. Temperature sensors are installed at specific static locations, whereas pressure and oil-film sensors are positioned in the runner and generate data during rotation. A special feature of the monitoring equipment is its on-line processing capability. Digital signal processors operating in parallel handle pressure and oil-film thickness data. Important measurement parameters such as the maximum pressure, maximum temperature and minimum oil-film thickness are displayed on-line. Detailed three-dimensional temperature information on one of the load segments can be obtained from subsequent off-line data analysis. The system also calculates two-dimensional plots of the oil-film thickness and pressure for most of the 12 load segments.
AMEGO as a supernova alarm: alert, probe and diagnosis of Type Ia explosions
NASA Astrophysics Data System (ADS)
McEnery, Julie E.; Wang, Xilu
2017-08-01
A Type Ia supernova (SNIa) could go entirely unnoticed in the Milky Way and nearby starburst galaxies, due to the large optical and near-IR extinction in the dusty environment, low radio and X-ray luminosities, and a weak neutrino signal. But the recent SN2014J confirms that Type Ia supernovae emit γ-ray lines from 56Ni → 56Co → 56Fe radioactive decay, spanning 158 keV to 2.6 MeV. The Galaxy and nearby starbursts are optically thin to γ-rays, so the supernova line flux will suffer negligible extinction. The All-Sky Medium Energy Gamma-ray Observatory (AMEGO) will monitor the entire sky every 3 hours from ~200 keV to >10 GeV. Most of the SNIa gamma-ray lines are squarely within the AMEGO energy range. Thus AMEGO will be an ideal SNIa monitor and early warning system. We will show that the supernova signal is expected to emerge as distinct from the AMEGO background within days after the explosion in the SN2014J shell model. The early stage observations of SNIa will allow us to explore the progenitor types and the nucleosynthesis of SNIa. Moreover, with the excellent line sensitivity, AMEGO will be able to detect the SNIa at a rate of a few events per year and will obtain enough gamma-ray observations over the mission lifetimes (~10 SNIa) to sample the SNIa. The high SNIa detection rate will also enable the precise measurement of the 56Ni mass generated during the Type Ia explosion, which will help us test the cosmic distance calibration and probe the cosmic acceleration.
Guevara-Almaraz, E; Hinojosa-Reyes, L; Caballero-Quintero, A; Ruiz-Ruiz, E; Hernández-Ramírez, A; Guzmán-Mar, J L
2015-02-01
In this study, a multisyringe chromatography system (MSC) using a C18 monolithic column was proposed for the on-line monitoring of the photocatalytic degradation of isoniazid (INH, 10 mg L(-1)) and pyrazinamide (PYRA, 5mgL(-1)) mixtures in aqueous solution using a small sample volume (200 μL) with an on-line filtration device in a fully automated approach. During the photocatalytic oxidation using TiO2 or ZnO semiconductor materials, total organic carbon (TOC) and the formed intermediates were analyzed off-line using ion chromatography, ion exclusion HPLC, and ESI-MS/MS. The results showed that TiO2 exhibits a better photocatalytic activity than ZnO under UV irradiation (365 nm) for the degradation of INH and PYRA mixtures, generating 97% and 92% degradation, respectively. The optimal oxidation conditions were identified as pH 7 and 1.0 g L(-1) of TiO2 as catalyst. The mineralization of the initial organic compounds was confirmed by the regular decrease in TOC, which indicated 63% mineralization, and the quantitative release of nitrate and nitrite ions, which represent 33% of the nitrogen in these compounds. The major intermediates of INH degradation included isonicotinamide, isonicotinic acid, and pyridine, while the ESI-MS/MS analysis of PYRA aqueous solution after photocatalytic treatment showed the formation of pyrazin-2-ylmethanol, pyrazin-2-ol, and pyrazine. Three low-molecular weight compounds, acetamide, acetic acid and formic acid, were detected during INH and PYRA decomposition. PYRA was more resistant to photocatalytic degradation due to the presence of the pyrazine ring, which provides greater stability against OH attack. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multi-camera synchronization core implemented on USB3 based FPGA platform
NASA Astrophysics Data System (ADS)
Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Dias, Morgado
2015-03-01
Centered on Awaiba's NanEye CMOS image sensor family and a FPGA platform with USB3 interface, the aim of this paper is to demonstrate a new technique to synchronize up to 8 individual self-timed cameras with minimal error. Small form factor self-timed camera modules of 1 mm x 1 mm or smaller do not normally allow external synchronization. However, for stereo vision or 3D reconstruction with multiple cameras as well as for applications requiring pulsed illumination it is required to synchronize multiple cameras. In this work, the challenge of synchronizing multiple selftimed cameras with only 4 wire interface has been solved by adaptively regulating the power supply for each of the cameras. To that effect, a control core was created to constantly monitor the operating frequency of each camera by measuring the line period in each frame based on a well-defined sampling signal. The frequency is adjusted by varying the voltage level applied to the sensor based on the error between the measured line period and the desired line period. To ensure phase synchronization between frames, a Master-Slave interface was implemented. A single camera is defined as the Master, with its operating frequency being controlled directly through a PC based interface. The remaining cameras are setup in Slave mode and are interfaced directly with the Master camera control module. This enables the remaining cameras to monitor its line and frame period and adjust their own to achieve phase and frequency synchronization. The result of this work will allow the implementation of smaller than 3mm diameter 3D stereo vision equipment in medical endoscopic context, such as endoscopic surgical robotic or micro invasive surgery.
Image synchronization for 3D application using the NanEye sensor
NASA Astrophysics Data System (ADS)
Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Dias, Morgado
2015-03-01
Based on Awaiba's NanEye CMOS image sensor family and a FPGA platform with USB3 interface, the aim of this paper is to demonstrate a novel technique to perfectly synchronize up to 8 individual self-timed cameras. Minimal form factor self-timed camera modules of 1 mm x 1 mm or smaller do not generally allow external synchronization. However, for stereo vision or 3D reconstruction with multiple cameras as well as for applications requiring pulsed illumination it is required to synchronize multiple cameras. In this work, the challenge to synchronize multiple self-timed cameras with only 4 wire interface has been solved by adaptively regulating the power supply for each of the cameras to synchronize their frame rate and frame phase. To that effect, a control core was created to constantly monitor the operating frequency of each camera by measuring the line period in each frame based on a well-defined sampling signal. The frequency is adjusted by varying the voltage level applied to the sensor based on the error between the measured line period and the desired line period. To ensure phase synchronization between frames of multiple cameras, a Master-Slave interface was implemented. A single camera is defined as the Master entity, with its operating frequency being controlled directly through a PC based interface. The remaining cameras are setup in Slave mode and are interfaced directly with the Master camera control module. This enables the remaining cameras to monitor its line and frame period and adjust their own to achieve phase and frequency synchronization. The result of this work will allow the realization of smaller than 3mm diameter 3D stereo vision equipment in medical endoscopic context, such as endoscopic surgical robotic or micro invasive surgery.
To v∞ and beyond! The He I absorption variability across the 2014.6 periastron passage of η Carinae
NASA Astrophysics Data System (ADS)
Richardson, Noel D.; Madura, Thomas I.; St-Jean, Lucas; Moffat, Anthony F. J.; Gull, Theodore R.; Russell, Christopher M. P.; Damineli, Augusto; Teodoro, Mairan; Corcoran, Michael F.; Walter, Frederick M.; Clementel, Nicola; Groh, José H.; Hamaguchi, Kenji; Hillier, D. John
2016-09-01
We have monitored the massive binary star η Carinae with the CTIO/Small and Moderate Aperture Research Telescope System 1.5 m telescope and CHIRON spectrograph from the previous apastron passage of the system through the recent 2014.6 periastron passage. Our monitoring has resulted in a large, homogeneous data set with an unprecedented time-sampling, spectral resolving power, and signal to noise. This allowed us to investigate temporal variability previously unexplored in the system and discover a kinematic structure in the P Cygni absorption troughs of neutral helium wind lines. The features observed occurred prior to the periastron passage and are seen as we look through the trailing arm of the wind-wind collision shock cone. We show that the bulk of the variability is repeatable across the last five periastron passages, and that the absorption occurs in the inner 230 au of the system. In addition, we found an additional, high-velocity absorption component superimposed on the P Cygni absorption troughs that has been previously unobserved in these lines, but which bears resemblance to the observations of the He I λ10830 Å feature across previous cycles. Through a comparison of the current smoothed particle hydrodynamical simulations, we show that the observed variations are likely caused by instabilities in the wind-wind collision region in our line of sight, coupled with stochastic variability related to clumping in the winds.
Transgenic mouse lines for non-invasive ratiometric monitoring of intracellular chloride
Batti, Laura; Mukhtarov, Marat; Audero, Enrica; Ivanov, Anton; Paolicelli, Rosa Chiara; Zurborg, Sandra; Gross, Cornelius; Bregestovski, Piotr; Heppenstall, Paul A.
2013-01-01
Chloride is the most abundant physiological anion and participates in a variety of cellular processes including trans-epithelial transport, cell volume regulation, and regulation of electrical excitability. The development of tools to monitor intracellular chloride concentration ([Cli]) is therefore important for the evaluation of cellular function in normal and pathological conditions. Recently, several Cl-sensitive genetically encoded probes have been described which allow for non-invasive monitoring of [Cli]. Here we describe two mouse lines expressing a CFP-YFP-based Cl probe called Cl-Sensor. First, we generated transgenic mice expressing Cl-Sensor under the control of the mouse Thy1 mini promoter. Cl-Sensor exhibited good expression from postnatal day two (P2) in neurons of the hippocampus and cortex, and its level increased strongly during development. Using simultaneous whole-cell monitoring of ionic currents and Cl-dependent fluorescence, we determined that the apparent EC50 for Cli was 46 mM, indicating that this line is appropriate for measuring neuronal [Cli] in postnatal mice. We also describe a transgenic mouse reporter line for Cre-dependent conditional expression of Cl-Sensor, which was targeted to the Rosa26 locus and by incorporating a strong exogenous promoter induced robust expression upon Cre-mediated recombination. We demonstrate high levels of tissue-specific expression in two different Cre-driver lines targeting cells of the myeloid lineage and peripheral sensory neurons. Using these mice the apparent EC50 for Cli was estimated to be 61 and 54 mM in macrophages and DRG, respectively. Our data suggest that these mouse lines will be useful models for ratiometric monitoring of Cli in specific cell types in vivo. PMID:23734096
Wan, Boyong; Zordan, Christopher A; Lu, Xujin; McGeorge, Gary
2016-10-01
Complete dissolution of the active pharmaceutical ingredient (API) is critical in the manufacturing of liquid-filled soft-gelatin capsules (SGC). Attenuated total reflectance UV spectroscopy (ATR-UV) and Raman spectroscopy have been investigated for in-line monitoring of API dissolution during manufacturing of an SGC product. Calibration models have been developed with both techniques for in-line determination of API potency. Performance of both techniques was evaluated and compared. The ATR-UV methodology was found to be able to monitor the dissolution process and determine the endpoint, but was sensitive to temperature variations. The Raman technique was also capable of effectively monitoring the process and was more robust to the temperature variation and process perturbations by using an excipient peak for internal correction. Different data preprocessing methodologies were explored in an attempt to improve method performance.
Flow-based ammonia gas analyzer with an open channel scrubber for indoor environments.
Ohira, Shin-Ichi; Heima, Minako; Yamasaki, Takayuki; Tanaka, Toshinori; Koga, Tomoko; Toda, Kei
2013-11-15
A robust and fully automated indoor ammonia gas monitoring system with an open channel scrubber (OCS) was developed. The sample gas channel dimensions, hydrophilic surface treatment to produce a thin absorbing solution layer, and solution flow rate of the OCS were optimized to connect the OCS as in-line gas collector and avoid sample humidity effects. The OCS effluent containing absorbed ammonia in sample gas was injected into a derivatization solution flow. Derivatization was achieved with o-phthalaldehyde and sulfite in pH 11 buffer solution. The product, 1-sulfonateisoindole, is detected with a home-made fluorescence detector. The limit of detection of the analyzer based on three times the standard deviation of baseline noise was 0.9 ppbv. Sample gas could be analyzed 40 times per hour. Furthermore, relative humidity of up to 90% did not interfere considerably with the analyzer. Interference from amines was not observed. The developed gas analysis system was calibrated using a solution-based method. The system was used to analyze ammonia in an indoor environment along with an off-site method, traditional impinger gas collection followed by ion chromatographic analysis, for comparison. The results obtained using both methods agreed well. Therefore, the developed system can perform on-site monitoring of ammonia in indoor environments with improved time resolution compared with that of other methods. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yordanov, Nicola D.; Aleksieva, Katerina
2004-01-01
X- and Q-band EPR studies after γ-irradiation of some dry spices and aromatic herbs are reported. Before irradiation all samples show only one singlet line in X-band EPR, whereas the Q-band EPR spectrum of the same samples is a superposition of two individual spectra—one corresponding to the above EPR signal, with an anisotropic spectrum, and a second one consisting of six lines due to the Mn 2+ naturally present in plants. The radiation induced EPR signal due to cellulose free radicals was not detected after γ-irradiation, but only the increase of the natural signal present before the irradiation. The fading kinetic of this EPR signal was monitored in three cases—when samples were kept in plastic bags without any special conditioning after irradiation, when samples were covered with paraffin before irradiation and when samples were dried at 60°C for 1 h before irradiation. The studies show that stability of radiation induced EPR signals decreases in the order of: paraffin covered > heated before irradiation > kept at room conditions. The two EPR spectra in the Q-band—one with radiation dependent intensity and a second due to Mn 2+, which is radiation independent allow identification of previous radiation treatment based on the fact that Mn 2+ quantity in the sample is constant whereas the quantity of radiation-induced free radicals is temperature dependent. It was found that for irradiated samples the ratio between EPR intensity of the free radicals and that of Mn 2+ before and after heating decreases with 50-60% whereas for non-irradiated samples it is ca. 10-15%.
Wright, Stephen; Boyd, Mark A.; Yunihastuti, Evy; Law, Matthew; Sirisanthana, Thira; Hoy, Jennifer; Pujari, Sanjay; Lee, Man Po; Petoumenos, Kathy
2013-01-01
Background In the Asia-Pacific region many countries have adopted the WHO’s public health approach to HIV care and treatment. We performed exploratory analyses of the factors associated with first major modification to first-line combination antiretroviral therapy (ART) in resource-rich and resource-limited countries in the region. Methods We selected treatment naive HIV-positive adults from the Australian HIV Observational Database (AHOD) and the TREAT Asia HIV Observational Database (TAHOD). We dichotomised each country’s per capita income into high/upper-middle (T-H) and lower-middle/low (T-L). Survival methods stratified by income were used to explore time to first major modification of first-line ART and associated factors. We defined a treatment modification as either initiation of a new class of antiretroviral (ARV) or a substitution of two or more ARV agents from within the same ARV class. Results A total of 4250 patients had 961 major modifications to first-line ART in the first five years of therapy. The cumulative incidence (95% CI) of treatment modification was 0.48 (0.44–0.52), 0.33 (0.30–0.36) and 0.21 (0.18–0.23) for AHOD, T-H and T-L respectively. We found no strong associations between typical patient characteristic factors and rates of treatment modification. In AHOD, relative to sites that monitor twice-yearly (both CD4 and HIV RNA-VL), quarterly monitoring corresponded with a doubling of the rate of treatment modifications. In T-H, relative to sites that monitor once-yearly (both CD4 and HIV RNA-VL), monitoring twice-yearly corresponded to a 1.8 factor increase in treatment modifications. In T-L, no sites on average monitored both CD4 & HIV RNA-VL concurrently once-yearly. We found no differences in rates of modifications for once- or twice-yearly CD4 count monitoring. Conclusions Low-income countries tended to have lower rates of major modifications made to first-line ART compared to higher-income countries. In higher-income countries, an increased rate of RNA-VL monitoring was associated with increased modifications to first-line ART. PMID:23840312
Wright, Stephen; Boyd, Mark A; Yunihastuti, Evy; Law, Matthew; Sirisanthana, Thira; Hoy, Jennifer; Pujari, Sanjay; Lee, Man Po; Petoumenos, Kathy
2013-01-01
In the Asia-Pacific region many countries have adopted the WHO's public health approach to HIV care and treatment. We performed exploratory analyses of the factors associated with first major modification to first-line combination antiretroviral therapy (ART) in resource-rich and resource-limited countries in the region. We selected treatment naive HIV-positive adults from the Australian HIV Observational Database (AHOD) and the TREAT Asia HIV Observational Database (TAHOD). We dichotomised each country's per capita income into high/upper-middle (T-H) and lower-middle/low (T-L). Survival methods stratified by income were used to explore time to first major modification of first-line ART and associated factors. We defined a treatment modification as either initiation of a new class of antiretroviral (ARV) or a substitution of two or more ARV agents from within the same ARV class. A total of 4250 patients had 961 major modifications to first-line ART in the first five years of therapy. The cumulative incidence (95% CI) of treatment modification was 0.48 (0.44-0.52), 0.33 (0.30-0.36) and 0.21 (0.18-0.23) for AHOD, T-H and T-L respectively. We found no strong associations between typical patient characteristic factors and rates of treatment modification. In AHOD, relative to sites that monitor twice-yearly (both CD4 and HIV RNA-VL), quarterly monitoring corresponded with a doubling of the rate of treatment modifications. In T-H, relative to sites that monitor once-yearly (both CD4 and HIV RNA-VL), monitoring twice-yearly corresponded to a 1.8 factor increase in treatment modifications. In T-L, no sites on average monitored both CD4 & HIV RNA-VL concurrently once-yearly. We found no differences in rates of modifications for once- or twice-yearly CD4 count monitoring. Low-income countries tended to have lower rates of major modifications made to first-line ART compared to higher-income countries. In higher-income countries, an increased rate of RNA-VL monitoring was associated with increased modifications to first-line ART.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denton, M.S.; Bostick, W.D.; Dinsmore, S.R.
1978-08-01
We describe a new concept in continuously referenced monitoring of the isoenzyme activities of creatine kinase (EC 2.7.3.2) after liquid-chromatographic separation. After separation on a diethylaminoethyl-Sephacel column, the three isoenzymes of creatine kinase undergo a series of coupled enzyme reactions, ultimately resulting in the formation of ultraviolet-detectable NADPH. A major advantage of this detection system is the immobilized-enzyme microreactor (2 x 17 mm), which may be removed and stored refrigerated when not in use. A split-stream configuration allows self-blanking of endogenous ultraviolet-absorbing constituents in authentic sera samples, which would otherwise make definitive diagnosis and quantitation difficult or impossible. This detectionmore » system is applicable to the automated analysis of creatine kinase isoenzymes in the clinical laboratory.« less
Chávez-Moreno, Carmín; Ferrer, Laura; Hinojosa-Reyes, Laura; Hernández-Ramírez, Aracely; Cerdà, Víctor; Guzmán-Mar, Jorge
2013-11-15
A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 μg L(-1) for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 μg L(-1) for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 μg L(-1) for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 μg L(-1) for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water. Copyright © 2013 Elsevier Ltd. All rights reserved.
Garcia-Allende, P Beatriz; Mirapeix, Jesus; Conde, Olga M; Cobo, Adolfo; Lopez-Higuera, Jose M
2009-01-01
Plasma optical spectroscopy is widely employed in on-line welding diagnostics. The determination of the plasma electron temperature, which is typically selected as the output monitoring parameter, implies the identification of the atomic emission lines. As a consequence, additional processing stages are required with a direct impact on the real time performance of the technique. The line-to-continuum method is a feasible alternative spectroscopic approach and it is particularly interesting in terms of its computational efficiency. However, the monitoring signal highly depends on the chosen emission line. In this paper, a feature selection methodology is proposed to solve the uncertainty regarding the selection of the optimum spectral band, which allows the employment of the line-to-continuum method for on-line welding diagnostics. Field test results have been conducted to demonstrate the feasibility of the solution.
Li, Hongkun; He, Changbo; Malekian, Reza; Li, Zhixiong
2018-04-19
The Centrifugal compressor is a piece of key equipment for petrochemical factories. As the core component of a compressor, the blades suffer periodic vibration and flow induced excitation mechanism, which will lead to the occurrence of crack defect. Moreover, the induced blade defect usually has a serious impact on the normal operation of compressors and the safety of operators. Therefore, an effective blade crack identification method is particularly important for the reliable operation of compressors. Conventional non-destructive testing and evaluation (NDT&E) methods can detect the blade defect effectively, however, the compressors should shut down during the testing process which is time-consuming and costly. In addition, it can be known these methods are not suitable for the long-term on-line condition monitoring and cannot identify the blade defect in time. Therefore, the effective on-line condition monitoring and weak defect identification method should be further studied and proposed. Considering the blade vibration information is difficult to measure directly, pressure sensors mounted on the casing are used to sample airflow pressure pulsation signal on-line near the rotating impeller for the purpose of monitoring the blade condition indirectly in this paper. A big problem is that the blade abnormal vibration amplitude induced by the crack is always small and this feature information will be much weaker in the pressure signal. Therefore, it is usually difficult to identify blade defect characteristic frequency embedded in pressure pulsation signal by general signal processing methods due to the weakness of the feature information and the interference of strong noise. In this paper, continuous wavelet transform (CWT) is used to pre-process the sampled signal first. Then, the method of bistable stochastic resonance (SR) based on Woods-Saxon and Gaussian (WSG) potential is applied to enhance the weak characteristic frequency contained in the pressure pulsation signal. Genetic algorithm (GA) is used to obtain optimal parameters for this SR system to improve its feature enhancement performance. The analysis result of experimental signal shows the validity of the proposed method for the enhancement and identification of weak defect characteristic. In the end, strain test is carried out to further verify the accuracy and reliability of the analysis result obtained by pressure pulsation signal.
Li, Hongkun; He, Changbo
2018-01-01
The Centrifugal compressor is a piece of key equipment for petrochemical factories. As the core component of a compressor, the blades suffer periodic vibration and flow induced excitation mechanism, which will lead to the occurrence of crack defect. Moreover, the induced blade defect usually has a serious impact on the normal operation of compressors and the safety of operators. Therefore, an effective blade crack identification method is particularly important for the reliable operation of compressors. Conventional non-destructive testing and evaluation (NDT&E) methods can detect the blade defect effectively, however, the compressors should shut down during the testing process which is time-consuming and costly. In addition, it can be known these methods are not suitable for the long-term on-line condition monitoring and cannot identify the blade defect in time. Therefore, the effective on-line condition monitoring and weak defect identification method should be further studied and proposed. Considering the blade vibration information is difficult to measure directly, pressure sensors mounted on the casing are used to sample airflow pressure pulsation signal on-line near the rotating impeller for the purpose of monitoring the blade condition indirectly in this paper. A big problem is that the blade abnormal vibration amplitude induced by the crack is always small and this feature information will be much weaker in the pressure signal. Therefore, it is usually difficult to identify blade defect characteristic frequency embedded in pressure pulsation signal by general signal processing methods due to the weakness of the feature information and the interference of strong noise. In this paper, continuous wavelet transform (CWT) is used to pre-process the sampled signal first. Then, the method of bistable stochastic resonance (SR) based on Woods-Saxon and Gaussian (WSG) potential is applied to enhance the weak characteristic frequency contained in the pressure pulsation signal. Genetic algorithm (GA) is used to obtain optimal parameters for this SR system to improve its feature enhancement performance. The analysis result of experimental signal shows the validity of the proposed method for the enhancement and identification of weak defect characteristic. In the end, strain test is carried out to further verify the accuracy and reliability of the analysis result obtained by pressure pulsation signal. PMID:29671821
McEwan, T.E.
1995-11-28
A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing. 17 figs.
McEwan, Thomas E.
1995-01-01
A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing.
[Study on Ammonia Emission Rules in a Dairy Feedlot Based on Laser Spectroscopy Detection Method].
He, Ying; Zhang, Yu-jun; You, Kun; Wang, Li-ming; Gao, Yan-wei; Xu, Jin-feng; Gao, Zhi-ling; Ma, Wen-qi
2016-03-01
It needs on-line monitoring of ammonia concentration on dairy feedlot to disclose ammonia emissions characteristics accurately for reducing ammonia emissions and improving the ecological environment. The on-line monitoring system for ammonia concentration has been designed based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology combining with long open-path technology, then the study has been carried out with inverse dispersion technique and the system. The ammonia concentration in-situ has been detected and ammonia emission rules have been analyzed on a dairy feedlot in Baoding in autumn and winter of 2013. The monitoring indicated that the peak of ammonia concentration was 6.11 x 10(-6) in autumn, and that was 6.56 x 10(-6) in winter. The concentration results show that the variation of ammonia concentration had an obvious diurnal periodicity, and the general characteristic of diurnal variation was that the concentration was low in the daytime and was high at night. The ammonia emissions characteristic was obtained with inverse dispersion model that the peak of ammonia emissions velocity appeared at noon. The emission velocity was from 1.48 kg/head/hr to 130.6 kg/head/hr in autumn, and it was from 0.004 5 kg/head/hr to 43.32 kg/head/hr in winter which was lower than that in autumn. The results demonstrated ammonia emissions had certain seasonal differences in dairy feedlot scale. In conclusion, the ammonia concentration was detected with optical technology, and the ammonia emissions results were acquired by inverse dispersion model analysis with large range, high sensitivity, quick response without gas sampling. Thus, it's an effective method for ammonia emissions monitoring in dairy feedlot that provides technical support for scientific breeding.
Riparian Vegetation Base-line Analysis and Monitoring Along Bishop Creek, California
Janet L. Nachlinger; Carl A. Fox; Patricia A. Moen
1989-01-01
A base-line analysis and long-term monitoring study of the riparian system along California's Bishop Creek is being conducted to measure the effects that planned increases in streamflow may have on riparian vegetation and associated wildlife. Six sites located in different major physiographic valley types have been selected for study. Biotic, climatologic,...
Ekdahl, Jr., Carl A.; Frost, Charles A.
1986-01-01
An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.
Ekdahl, C.A. Jr.; Frost, C.A.
1984-11-13
An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.
Optical transmission measurements for in-line monitoring of turbid oil-water emulsions
NASA Astrophysics Data System (ADS)
Metz, Philipp; Dopf, Katja; Aichholz, Markus; Riedel, Boris; Lemmer, Uli; Freudig, Barbara; Zimmermann, Clifton; Gerken, Martina
2014-05-01
For absorbing media the concentration may be calculated directly from the optical transmission following the logarithmic dependence given in the Lambert-Beer law. Due to multiple scattering events in oil-water emulsions (e.g. milk, cream, etc.), these exhibit a nonlinear relationship between the attenuation and the oil concentration. We demonstrate that for increasing oil content in oil-water emulsions the attenuation first increases, then levels out, and finally even decreases for a fat content of 60%. Single-wavelength optical transmission measurements are found to be well suited for the in-line monitoring of oil-water emulsions of fat contents below 20%, e.g., for the in-line fat content monitoring of milk. Using experiments and ray-tracing simulations we evaluate system optimization.
Methods and Metrics for Evaluating Environmental Dredging ...
This report documents the objectives, approach, methodologies, results, and interpretation of a collaborative research study conducted by the National Risk Management Research Laboratory (NRMRL) and the National Exposure Research laboratory (NERL) of the U.S. Environmental Protection Agency’s (U.S. EPA’s) Office of Research and Development (ORD) and the U.S. EPA’s Great Lakes National Program Office (GLNPO). The objectives of the research study were to: 1) evaluate remedy effectiveness of environmental dredging as applied to contaminated sediments in the Ashtabula River in northeastern Ohio, and 2) monitor the recovery of the surrounding ecosystem. The project was carried out over 6 years from 2006 through 2011 and consisted of the development and evaluation of methods and approaches to assess river and ecosystem conditions prior to dredging (2006), during dredging (2006 and 2007), and following dredging, both short term (2008) and long term (2009-2011). This project report summarizes and interprets the results of this 6-year study to develop and assess methods for monitoring pollutant fate and transport and ecosystem recovery through the use of biological, chemical, and physical lines of evidence (LOEs) such as: 1) comprehensive sampling of and chemical analysis of contaminants in surface, suspended, and historic sediments; 2) extensive grab and multi-level real time water sampling and analysis of contaminants in the water column; 3) sampling, chemi
Towards innovative roadside monitoring
NASA Astrophysics Data System (ADS)
Ojha, G.; Appel, E.; Magiera, T.
2012-04-01
Soil contamination along roadsides is an important factor of anthropogenic point source pollution. Climatic and traffic-specific factors influence the amount and characteristics of pollution emitted and deposited in the roadside soil. In our present study we focus on monitoring typical traffic pollutants (heavy metals HM, platinum group elements, polycyclic hydrocarbons PAH), and investigate the use of magnetic parameters, especially magnetic susceptibility (MS) as proxy. Monitoring plots were installed along roadside in areas with different climatic conditions and different traffic-specific activities (traffic density and speed, vehicle types, abrasion of tires, brake linings, petrol/diesel compounds and road maintenance). For monitoring we removed 10-15 cm of top soil at 1 m distance from the roadside edge and placed 30 plastic boxes there filled with clean quartz sand, to be sampled after regular intervals within two years. Preliminary data from the first year of monitoring are presented. Magnetic results revealed that a coarse grained magnetite-like phase is responsible for the enhancement of magnetic concentration. The mass-specific MS and concentration of pollutants (HM, PAH) all show a significant increase with time, however, there are obviously also seasonal and site-dependent effects which lead to more stable values over several months or even some decrease in the upper few cm due to migration into depth. Source identification indicates that the accumulated PAHs are primarily emissions from traffic. In order to be able to discriminate in between different kinds of transport and deposition (surface run off from the road and neighbouring soil material, splash water, air transport), we additionally established pillars at the roadside with clean quartz sampling boxes at different heights (surface, 0.5 m, 2 m). As a first surprising result we observed that the increase in the boxes at surface is not necessarily higher than at 0.5 m height. The results from our monitoring studies will be utilized to understand site-specific characteristics and to develop new innovative roadside pollution monitoring concepts.
A new mask exposure and analysis facility
NASA Astrophysics Data System (ADS)
te Sligte, Edwin; Koster, Norbert; Deutz, Alex; Staring, Wilbert
2014-10-01
The introduction of ever higher source powers in EUV systems causes increased risks for contamination and degradation of EUV masks and pellicles. Appropriate testing can help to inventory and mitigate these risks. To this end, we propose EBL2: a laboratory EUV exposure system capable of operating at high EUV powers and intensities, and capable of exposing and analyzing EUV masks. The proposed system architecture is similar to the EBL system which has been operated jointly by TNO and Carl Zeiss SMT since 2005. EBL2 contains an EUV Beam Line, in which samples can be exposed to EUV irradiation in a controlled environment. Attached to this Beam Line is an XPS system, which can be reached from the Beam Line via an in-vacuum transfer system. This enables surface analysis of exposed masks without breaking vacuum. Automated handling with dual pods is foreseen so that exposed EUV masks will still be usable in EUV lithography tools to assess the imaging impact of the exposure. Compared to the existing system, large improvements in EUV power, intensity, reliability, and flexibility are proposed. Also, in-situ measurements by e.g. ellipsometry is foreseen for real time monitoring of the sample condition. The system shall be equipped with additional ports for EUVR or other analysis tools. This unique facility will be open for external customers and other research groups.
LABORATORY EVALUATION OF A MICROFLUIDIC ELECTROCHEMICAL SENSOR FOR AEROSOL OXIDATIVE LOAD.
Koehler, Kirsten; Shapiro, Jeffrey; Sameenoi, Yupaporn; Henry, Charles; Volckens, John
2014-05-01
Human exposure to particulate matter (PM) air pollution is associated with human morbidity and mortality. The mechanisms by which PM impacts human health are unresolved, but evidence suggests that PM intake leads to cellular oxidative stress through the generation of reactive oxygen species (ROS). Therefore, reliable tools are needed for estimating the oxidant generating capacity, or oxidative load, of PM at high temporal resolution (minutes to hours). One of the most widely reported methods for assessing PM oxidative load is the dithiothreitol (DTT) assay. The traditional DTT assay utilizes filter-based PM collection in conjunction with chemical analysis to determine the oxidation rate of reduced DTT in solution with PM. However, the traditional DTT assay suffers from poor time resolution, loss of reactive species during sampling, and high limit of detection. Recently, a new DTT assay was developed that couples a Particle-Into-Liquid-Sampler with microfluidic-electrochemical detection. This 'on-line' system allows high temporal resolution monitoring of PM reactivity with improved detection limits. This study reports on a laboratory comparison of the traditional and on-line DTT approaches. An urban dust sample was aerosolized in a laboratory test chamber at three atmospherically-relevant concentrations. The on-line system gave a stronger correlation between DTT consumption rate and PM mass (R 2 = 0.69) than the traditional method (R 2 = 0.40) and increased precision at high temporal resolution, compared to the traditional method.
Sandiford, P
1993-09-01
In recent years Lot quality assurance sampling (LQAS), a method derived from production-line industry, has been advocated as an efficient means to evaluate the coverage rates achieved by child immunization programmes. This paper examines the assumptions on which LQAS is based and the effect that these assumptions have on its utility as a management tool. It shows that the attractively low sample sizes used in LQAS are achieved at the expense of specificity unless unrealistic assumptions are made about the distribution of coverage rates amongst the immunization programmes to which the method is applied. Although it is a very sensitive test and its negative predictive value is probably high in most settings, its specificity and positive predictive value are likely to be low. The implications of these strengths and weaknesses with regard to management decision-making are discussed.
NASA Astrophysics Data System (ADS)
Min, M.
2017-10-01
Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.
Nicholls, Colin I.
1992-07-14
An on-line product sampling apparatus and method for measuring product samples from a product stream (12) in a flow line (14) having a sampling aperture (11), includes a sampling tube (18) for containing product samples removed from flow line (14). A piston (22) removes product samples from the product stream (12) through the sampling aperture (11) and returns samples to product stream (12). A sensor (20) communicates with sample tube (18), and senses physical properties of samples while the samples are within sample tube (18). In one embodiment, sensor (20) comprises a hydrogen transient nuclear magnetic resonance sensor for measuring physical properties of hydrogen molecules.
Teague, Nicholas F.; Brown, Anthony A.; Woolfenden, Linda R.
2014-01-01
The Rialto-Colton Basin is in western San Bernardino County, about 60 miles east of Los Angeles, California. The basin is bounded by faults on the northeast and southwest sides and contains multiple barriers to groundwater flow. The structural geology of the basin leads to complex hydrology. Between 2001 and 2008, in an effort to better understand the complex hydrologic system of the Rialto-Colton Basin, seven multiple-well monitoring sites were constructed. Two to six observation wells were installed in the borehole at each site; a total of 32 observation wells were installed. This report presents geologic, hydrologic, and water-quality data collected from these seven multiple-well monitoring sites. Descriptions of the collected drill cuttings were compiled into lithologic logs for each monitoring site. The lithologic logs are summarized along with the geophysical logs, including gamma-ray, spontaneous potential, resistivity, and electromagnetic induction tool logs. At selected sites, sonic tool logs also were recorded. Periodic water-level measurements are reported, and water-level data are displayed on hydrographs. Water levels at multiple-well monitoring sites in the northern part of the study area differed between the shallow and deep observation wells; in the remaining multiple-well monitoring sites, water levels differed little with depth. Along the southern trace of the Rialto-Colton Fault, water levels are slightly higher east of the fault than west of the fault. Selected water-quality data for 21 of the observation wells show water from wells in the northern and central parts of the study area is calcium-carbonate water. In the southern part of the study area, water from wells screened above 400 feet below land surface is of mixed type or is calcium-carbonate water. Water from wells screened greater than 400 feet below land surface in the southern part of the study area is sodium-carbonate or sodium-mixed anion water. Water from most wells in the study area plots above the Global Meteoric Water Line along an apparent local meteoric water line, indicating the water has not experienced substantial evaporation before infiltration. A few samples from shallow wells in the study area plot slightly to the right of the Global Meteoric Water Line, possibly indicating the water experienced some evaporation before recharge.
OpenLMD, multimodal monitoring and control of LMD processing
NASA Astrophysics Data System (ADS)
Rodríguez-Araújo, Jorge; García-Díaz, Antón
2017-02-01
This paper presents OpenLMD, a novel open-source solution for on-line multimodal monitoring of Laser Metal Deposition (LMD). The solution is also applicable to a wider range of laser-based applications that require on-line control (e.g. laser welding). OpenLMD is a middleware that enables the orchestration and virtualization of a LMD robot cell, using several open-source frameworks (e.g. ROS, OpenCV, PCL). The solution also allows reconfiguration by easy integration of multiple sensors and processing equipment. As a result, OpenLMD delivers significant advantages over existing monitoring and control approaches, such as improved scalability, and multimodal monitoring and data sharing capabilities.
Idder, Salima; Ley, Laurent; Mazellier, Patrick; Budzinski, Hélène
2013-12-17
One of the current environmental issues concerns the presence and fate of pharmaceuticals in water bodies as these compounds may represent a potential environmental problem. The characterization of pharmaceutical contamination requires powerful analytical method able to quantify these pollutants at very low concentration (few ng L(-1)). In this work, a multi-residue analytical methodology (on-line solid phase extraction-liquid chromatography-triple quadrupole mass spectrometry using positive and negative electrospray ionization) has been developed and validated for 40 multi-class pharmaceuticals and metabolites for tap and surface waters. This on-line SPE method was very convenient and efficient compared to classical off-line SPE method because of its shorter total run time including sample preparation and smaller sample volume (1 mL vs up to 1 L). The optimized method included several therapeutic classes as lipid regulators, antibiotics, beta-blockers, non-steroidal anti-inflammatories, antineoplastic, etc., with various physicochemical properties. Quantification has been achieved with the internal standards. The limits of detection are between 0.7 and 15 ng L(-1) for drinking waters and 2-15 ng L(-1) for surface waters. The inter-day precision values are below 20% for each studied level. The improvement and strength of the analytical method has been verified along a monitoring of these 40 pharmaceuticals in Isle River, a French stream located in the South West of France. During this survey, 16 pharmaceutical compounds have been detected. Copyright © 2013 Elsevier B.V. All rights reserved.
Engineering considerations for corrosion monitoring of gas gathering pipeline systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braga, T.G.; Asperger, R.G.
1987-01-01
Proper corrosion monitoring of gas gathering pipelines requires a system review to determine the appropriate monitor locations and types of monitoring techniques. This paper develops and discusses a classification of conditions such as flow regime and gas composition. Also discussed are junction categories which, for corrosion monitoring, need to be considered from two points of view. The first is related to fluid flow in the line and the second is related corrosion inhibitor movement along the pipeline. The appropriate application of the various monitoring techniques such as coupons, hydrogen detectors, electrical resistance probe and linear polarization probes are discussed inmore » relation to flow regime and gas composition. Problems caused by semi-conduction from iron sulfide are considered. Advantages and disadvantages of fluid gathering methods such as pots and flow-through drips are discussed in relation to their reliability as on-line monitoring locations.« less
Snowpack Chemistry of Reactive Gases at Station Concordia, Antarctica
NASA Astrophysics Data System (ADS)
Helmig, Detlev; Mass, Alex; Hueber, Jacques; Fain, Xavier; Dommergue, Aurelien; Barbero, Albane; Savarino, Joel
2013-04-01
During December 2012 a new experiment for the study of snow photochemical processes and surface gas exchange was installed at Dome Concordia, Antarctica. The experiment consists of two sampling manifolds ('snow tower') which facilitate the withdrawal of interstitial firn air from four depths in the snowpack and from above the surface. One of these snow towers can be shaded for investigation of the dependency of snow chemistry on solar radiation. A nearby 12 m meteorological tower facilitates above surface turbulence and trace gas gradient measurements. Temperature profiles and UV and IR light penetration are monitored in the snowpack. Air samples are directed through sampling lines to a nearby underground laboratory that houses the experiment control system and gas monitors. The system is fully automated, sampling gases from the array of inlet ports sequentially, and is intended to be operated continuously for a full annual cycle. The computerized control system can be accessed remotely for data retrieval and quality control and for configuring experimental details. Continuous gas measurements include ozone, nitrogen oxides, methane, carbon monoxide, and gaseous elemental mercury. Whole air samples were sampled on four occasions for volatile organic compound analysis. The objective of this research is the study of the year-round snowpack gas chemistry and its dependency on snowpack and above surface physical and environmental conditions. A particular emphasis will be the investigation of the effects of increased UV radiation during the occurrence of the stratospheric ozone hole. We will present the conceptual design of the experiment and data examples from the first three months of the experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elvado Environmental LLC
2009-09-01
This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2010 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2010 will be in accordance with requirements of DOE Order 540.1A and the following goals: (1) to protect the worker, the public, and the environment; (2) to maintain surveillance of existing and potential groundwater contamination sources; (3) to provide for the early detection of groundwater contaminationmore » and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; (4) to identify and characterize long-term trends in groundwater quality at Y-12; and (5) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2010 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation. Modifications to the CY 2010 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2010 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information. The narrative sections of the report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. Groundwater Monitoring Schedules (when issued throughout CY 2010) will be inserted in Appendix C, and addenda to this plan (if issued) will be inserted in Appendix D. Laboratory requirements (bottle lists, holding times, etc.) are provided in Appendix E, and an approved Waste Management Plan is provided in Appendix F.« less
Development of a model system to identify differences in spring and winter oat.
Chawade, Aakash; Lindén, Pernilla; Bräutigam, Marcus; Jonsson, Rickard; Jonsson, Anders; Moritz, Thomas; Olsson, Olof
2012-01-01
Our long-term goal is to develop a Swedish winter oat (Avena sativa). To identify molecular differences that correlate with winter hardiness, a winter oat model comprising of both non-hardy spring lines and winter hardy lines is needed. To achieve this, we selected 294 oat breeding lines, originating from various Russian, German, and American winter oat breeding programs and tested them in the field in south- and western Sweden. By assaying for winter survival and agricultural properties during four consecutive seasons, we identified 14 breeding lines of different origins that not only survived the winter but also were agronomically better than the rest. Laboratory tests including electrolytic leakage, controlled crown freezing assay, expression analysis of the AsVrn1 gene and monitoring of flowering time suggested that the American lines had the highest freezing tolerance, although the German lines performed better in the field. Finally, six lines constituting the two most freezing tolerant lines, two intermediate lines and two spring cultivars were chosen to build a winter oat model system. Metabolic profiling of non-acclimated and cold acclimated leaf tissue samples isolated from the six selected lines revealed differential expression patterns of 245 metabolites including several sugars, amino acids, organic acids and 181 hitherto unknown metabolites. The expression patterns of 107 metabolites showed significant interactions with either a cultivar or a time-point. Further identification, characterisation and validation of these metabolites will lead to an increased understanding of the cold acclimation process in oats. Furthermore, by using the winter oat model system, differential sequencing of crown mRNA populations would lead to identification of various biomarkers to facilitate winter oat breeding.
Development of at-line assay to monitor charge variants of MAbs during production.
St Amand, M M; Ogunnaike, B A; Robinson, A S
2014-01-01
One major challenge currently facing the biopharmaceutical industry is to understand how MAb microheterogeneity affects therapeutic efficacy, potency, immunogenicity, and clearance. MAb micro-heterogeneity can result from post-translational modifications such as sialylation, galactosylation, C-terminal lysine cleavage, glycine amidation, and tryptophan oxidation, each of which can generate MAb charge variants; such heterogeneity can affect pharmacokinetics (PK) considerably. Implementation of appropriate on-line quality control strategies may help to regulate bioprocesses, thus enabling more homogenous material with desired post-translational modifications and PK behavior. However, one major restriction to implementation of quality control strategies is the availability of techniques for obtaining on-line or at-line measurements of these attributes. In this work, we describe the development of an at-line assay to separate MAb charge variants in near real-time, which could ultimately be used to implement on-line quality control strategies for MAb production. The assay consists of a 2D-HPLC method with sequential in-line Protein A and WCX-10 HPLC column steps. To perform the 2D-HPLC assay at-line, the two columns steps were integrated into a single method using a novel system configuration that allowed parallel flow over column 1 or column 2 or sequential flow from column 1 to column 2. A bioreactor system was also developed such that media samples could be removed automatically from bioreactor vessels during production and delivered to the 2D-HPLC for analysis. With this at-line HPLC assay, we have demonstrated that MAb microheterogeneity occurs throughout the cell cycle whether the host cell line is grown under different or the same nominal culture conditions. © 2013 American Institute of Chemical Engineers.
García Diego, Fernando-Juan; Esteban, Borja; Merello, Paloma
2015-01-01
Preventive conservation represents a working method and combination of techniques which helps in determining and controlling the deterioration process of cultural heritage in order to take the necessary actions before it occurs. It is acknowledged as important, both in terms of preserving and also reducing the cost of future conservation measures. Therefore, long-term monitoring of physical parameters influencing cultural heritage is necessary. In the context of Smart Cities, monitoring of cultural heritage is of interest in order to perform future comparative studies and load information into the cloud that will be useful for the conservation of other heritage sites. In this paper the development of an economical and appropriate acquisition data system combining wired and wireless communication, as well as third party hardware for increased versatility, is presented. The device allows monitoring a complex network of points with high sampling frequency, with wired sensors in a 1-wire bus and a wireless centralized system recording data for monitoring of physical parameters, as well as the future possibility of attaching an alarm system or sending data over the Internet. This has been possible with the development of three board’s designs and more than 5000 algorithm lines. System tests have shown an adequate system operation. PMID:25815447
García Diego, Fernando-Juan; Esteban, Borja; Merello, Paloma
2015-03-25
Preventive conservation represents a working method and combination of techniques which helps in determining and controlling the deterioration process of cultural heritage in order to take the necessary actions before it occurs. It is acknowledged as important, both in terms of preserving and also reducing the cost of future conservation measures. Therefore, long-term monitoring of physical parameters influencing cultural heritage is necessary. In the context of Smart Cities, monitoring of cultural heritage is of interest in order to perform future comparative studies and load information into the cloud that will be useful for the conservation of other heritage sites. In this paper the development of an economical and appropriate acquisition data system combining wired and wireless communication, as well as third party hardware for increased versatility, is presented. The device allows monitoring a complex network of points with high sampling frequency, with wired sensors in a 1-wire bus and a wireless centralized system recording data for monitoring of physical parameters, as well as the future possibility of attaching an alarm system or sending data over the Internet. This has been possible with the development of three board's designs and more than 5000 algorithm lines. System tests have shown an adequate system operation.
Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions
NASA Astrophysics Data System (ADS)
Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming
2016-06-01
On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01-0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics.
Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions
Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming
2016-01-01
On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology–fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01–0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics. PMID:27352840
Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions.
Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming
2016-06-29
On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01-0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics.
Enhanced Raman Monitor Project
NASA Technical Reports Server (NTRS)
Westenskow, Dwayne
1996-01-01
Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.
An X-ray beam position monitor based on the photoluminescence of helium gas
NASA Astrophysics Data System (ADS)
Revesz, Peter; White, Jeffrey A.
2005-03-01
A new method for white beam position monitoring for both bend magnet and wiggler synchrotron X-ray radiation has been developed. This method utilizes visible light luminescence generated as a result of ionization by the intense X-ray flux. In video beam position monitors (VBPMs), the luminescence of helium gas at atmospheric pressure is observed through a view port using a CCD camera next to the beam line. The beam position, profile, integrated intensity and FWHM are calculated from the distribution of luminescence intensity in each captured image by custom software. Misalignment of upstream apertures changes the image profile making VBPMs helpful for initial alignment of upstream beam line components. VBPMs can thus provide more information about the X-ray beam than most beam position monitors (BPMs). A beam position calibration procedure, employing a tilted plane-parallel glass plate placed in front of the camera lens, has also been developed. The accuracy of the VBPM system was measured during a bench-top experiment to be better than 1 μm. The He-luminescence-based VBPM system has been operative on three CHESS beam lines (F hard-bend and wiggler, A-line wiggler and G-line wiggler) for about a year. The beam positions are converted to analog voltages and used as feedback signals for beam stabilization. In our paper we discuss details of VBPM construction and describe further results of its performance.
Transient digitizer with displacement current samplers
McEwan, T.E.
1996-05-21
A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board. 16 figs.
Transient digitizer with displacement current samplers
McEwan, Thomas E.
1996-01-01
A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.
Reischer, G H; Haider, J M; Sommer, R; Stadler, H; Keiblinger, K M; Hornek, R; Zerobin, W; Mach, R L; Farnleitner, A H
2008-10-01
The impairment of water quality by faecal pollution is a global public health concern. Microbial source tracking methods help to identify faecal sources but the few recent quantitative microbial source tracking applications disregarded catchment hydrology and pollution dynamics. This quantitative microbial source tracking study, conducted in a large karstic spring catchment potentially influenced by humans and ruminant animals, was based on a tiered sampling approach: a 31-month water quality monitoring (Monitoring) covering seasonal hydrological dynamics and an investigation of flood events (Events) as periods of the strongest pollution. The detection of a ruminant-specific and a human-specific faecal Bacteroidetes marker by quantitative real-time PCR was complemented by standard microbiological and on-line hydrological parameters. Both quantitative microbial source tracking markers were detected in spring water during Monitoring and Events, with preponderance of the ruminant-specific marker. Applying multiparametric analysis of all data allowed linking the ruminant-specific marker to general faecal pollution indicators, especially during Events. Up to 80% of the variation of faecal indicator levels during Events could be explained by ruminant-specific marker levels proving the dominance of ruminant faecal sources in the catchment. Furthermore, soil was ruled out as a source of quantitative microbial source tracking markers. This study demonstrates the applicability of quantitative microbial source tracking methods and highlights the prerequisite of considering hydrological catchment dynamics in source tracking study design.
Low-Resolution Radial-Velocity Monitoring of Pulsating sdBs in the Kepler Field
NASA Astrophysics Data System (ADS)
Telting, J.; Östensen, R.; Reed, M.; Kiæerad, F.; Farris, L.; Baran, A.; Oreiro, R.; O'Toole, S.
2014-04-01
We present preliminary results from an ongoing spectroscopic campaign to uncover the binary status of the 18 known pulsating subdwarf B stars and the one pulsating BHB star observed with the Kepler spacecraft. During the 2010-2012 observing seasons, we have used the KP4m Mayall, NOT, and WHT telescopes to obtain low-resolution (R˜2000-2500) Balmer-line spectroscopy of our sample stars. We applied a standard cross-correlation technique to derive radial velocities, and find clear evidence for binarity in several of the pulsators, some of which were not previously known to be binaries.
High-speed measurements of steel-plate deformations during laser surface processing.
Jezersek, Matija; Gruden, Valter; Mozina, Janez
2004-10-04
In this paper we present a novel approach to monitoring the deformations of a steel plate's surface during various types of laser processing, e.g., engraving, marking, cutting, bending, and welding. The measuring system is based on a laser triangulation principle, where the laser projector generates multiple lines simultaneously. This enables us to measure the shape of the surface with a high sampling rate (80 Hz with our camera) and high accuracy (+/-7 microm). The measurements of steel-plate deformations for plates of different thickness and with different illumination patterns are presented graphically and in an animation.
Pagani, Ioanna; Liolios, Konstantinos; Jansson, Jakob; Chen, I-Min A.; Smirnova, Tatyana; Nosrat, Bahador; Markowitz, Victor M.; Kyrpides, Nikos C.
2012-01-01
The Genomes OnLine Database (GOLD, http://www.genomesonline.org/) is a comprehensive resource for centralized monitoring of genome and metagenome projects worldwide. Both complete and ongoing projects, along with their associated metadata, can be accessed in GOLD through precomputed tables and a search page. As of September 2011, GOLD, now on version 4.0, contains information for 11 472 sequencing projects, of which 2907 have been completed and their sequence data has been deposited in a public repository. Out of these complete projects, 1918 are finished and 989 are permanent drafts. Moreover, GOLD contains information for 340 metagenome studies associated with 1927 metagenome samples. GOLD continues to expand, moving toward the goal of providing the most comprehensive repository of metadata information related to the projects and their organisms/environments in accordance with the Minimum Information about any (x) Sequence specification and beyond. PMID:22135293
Shukla, Chinmay A
2017-01-01
The implementation of automation in the multistep flow synthesis is essential for transforming laboratory-scale chemistry into a reliable industrial process. In this review, we briefly introduce the role of automation based on its application in synthesis viz. auto sampling and inline monitoring, optimization and process control. Subsequently, we have critically reviewed a few multistep flow synthesis and suggested a possible control strategy to be implemented so that it helps to reliably transfer the laboratory-scale synthesis strategy to a pilot scale at its optimum conditions. Due to the vast literature in multistep synthesis, we have classified the literature and have identified the case studies based on few criteria viz. type of reaction, heating methods, processes involving in-line separation units, telescopic synthesis, processes involving in-line quenching and process with the smallest time scale of operation. This classification will cover the broader range in the multistep synthesis literature. PMID:28684977
Pagani, Ioanna; Liolios, Konstantinos; Jansson, Jakob; Chen, I-Min A; Smirnova, Tatyana; Nosrat, Bahador; Markowitz, Victor M; Kyrpides, Nikos C
2012-01-01
The Genomes OnLine Database (GOLD, http://www.genomesonline.org/) is a comprehensive resource for centralized monitoring of genome and metagenome projects worldwide. Both complete and ongoing projects, along with their associated metadata, can be accessed in GOLD through precomputed tables and a search page. As of September 2011, GOLD, now on version 4.0, contains information for 11,472 sequencing projects, of which 2907 have been completed and their sequence data has been deposited in a public repository. Out of these complete projects, 1918 are finished and 989 are permanent drafts. Moreover, GOLD contains information for 340 metagenome studies associated with 1927 metagenome samples. GOLD continues to expand, moving toward the goal of providing the most comprehensive repository of metadata information related to the projects and their organisms/environments in accordance with the Minimum Information about any (x) Sequence specification and beyond.
Goovaerts, Pierre
2017-07-15
The delay in reporting high levels of lead in Flint drinking water, following the city's switch to the Flint River as its water supply, was partially caused by the biased selection of sampling sites away from the lead pipe network. Since Flint returned to its pre-crisis source of drinking water, the State has been monitoring water lead levels (WLL) at selected "sentinel" sites. In a first phase that lasted two months, 739 residences were sampled, most of them bi-weekly, to determine the general health of the distribution system and to track temporal changes in lead levels. During the same period, water samples were also collected through a voluntary program whereby concerned citizens received free testing kits and conducted sampling on their own. State officials relied on the former data to demonstrate the steady improvement in water quality. A recent analysis of data collected by voluntary sampling revealed, however, an opposite trend with lead levels increasing over time. This paper looks at potential sampling bias to explain such differences. Although houses with higher WLL were more likely to be sampled repeatedly, voluntary sampling turned out to reproduce fairly well the main characteristics (i.e. presence of lead service lines (LSL), construction year) of Flint housing stock. State-controlled sampling was less representative; e.g., sentinel sites with LSL were mostly built between 1935 and 1950 in lower poverty areas, which might hamper our ability to disentangle the effects of LSL and premise plumbing (lead fixtures and pipes present within old houses) on WLL. Also, there was no sentinel site with LSL in two of the most impoverished wards, including where the percentage of children with elevated blood lead levels tripled following the switch in water supply. Correcting for sampling bias narrowed the gap between sampling programs, yet overall temporal trends are still opposite. Copyright © 2017 Elsevier B.V. All rights reserved.
Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M
2017-04-08
Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.
Using PAT to accelerate the transition to continuous API manufacturing.
Gouveia, Francisca F; Rahbek, Jesper P; Mortensen, Asmus R; Pedersen, Mette T; Felizardo, Pedro M; Bro, Rasmus; Mealy, Michael J
2017-01-01
Significant improvements can be realized by converting conventional batch processes into continuous ones. The main drivers include reduction of cost and waste, increased safety, and simpler scale-up and tech transfer activities. Re-designing the process layout offers the opportunity to incorporate a set of process analytical technologies (PAT) embraced in the Quality-by-Design (QbD) framework. These tools are used for process state estimation, providing enhanced understanding of the underlying variability in the process impacting quality and yield. This work describes a road map for identifying the best technology to speed-up the development of continuous processes while providing the basis for developing analytical methods for monitoring and controlling the continuous full-scale reaction. The suitability of in-line Raman, FT-infrared (FT-IR), and near-infrared (NIR) spectroscopy for real-time process monitoring was investigated in the production of 1-bromo-2-iodobenzene. The synthesis consists of three consecutive reaction steps including the formation of an unstable diazonium salt intermediate, which is critical to secure high yield and avoid formation of by-products. All spectroscopic methods were able to capture critical information related to the accumulation of the intermediate with very similar accuracy. NIR spectroscopy proved to be satisfactory in terms of performance, ease of installation, full-scale transferability, and stability to very adverse process conditions. As such, in-line NIR was selected to monitor the continuous full-scale production. The quantitative method was developed against theoretical concentration values of the intermediate since representative sampling for off-line reference analysis cannot be achieved. The rapid and reliable analytical system allowed the following: speeding up the design of the continuous process and a better understanding of the manufacturing requirements to ensure optimal yield and avoid unreacted raw materials and by-products in the continuous reactor effluent. Graphical Abstract Using PAT to accelerate the transition to continuous API manufacturing.
Mjollnir Rotational Line Scan Diagnostics.
1981-05-19
using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored
In-line mixing states monitoring of suspensions using ultrasonic reflection technique.
Zhan, Xiaobin; Yang, Yili; Liang, Jian; Zou, Dajun; Zhang, Jiaqi; Feng, Luyi; Shi, Tielin; Li, Xiwen
2016-02-01
Based on the measurement of echo signal changes caused by different concentration distributions in the mixing process, a simple ultrasonic reflection technique is proposed for in-line monitoring of the mixing states of suspensions in an agitated tank in this study. The relation between the echo signals and the concentration of suspensions is studied, and the mixing process of suspensions is tracked by in-line measurement of ultrasonic echo signals using two ultrasonic sensors. Through the analysis of echo signals over time, the mixing states of suspensions are obtained, and the homogeneity of suspensions is quantified. With the proposed technique, the effects of impeller diameter and agitation speed on the mixing process are studied, and the optimal agitation speed and the minimum mixing time to achieve the maximum homogeneity are acquired under different operating conditions and design parameters. The proposed technique is stable and feasible and shows great potential for in-line monitoring of mixing states of suspensions. Copyright © 2015 Elsevier B.V. All rights reserved.
Schmidt, Martin; Van Bel, Michiel; Woloszynska, Magdalena; Slabbinck, Bram; Martens, Cindy; De Block, Marc; Coppens, Frederik; Van Lijsebettens, Mieke
2017-07-06
Cytosine methylation in plant genomes is important for the regulation of gene transcription and transposon activity. Genome-wide methylomes are studied upon mutation of the DNA methyltransferases, adaptation to environmental stresses or during development. However, from basic biology to breeding programs, there is a need to monitor multiple samples to determine transgenerational methylation inheritance or differential cytosine methylation. Methylome data obtained by sodium hydrogen sulfite (bisulfite)-conversion and next-generation sequencing (NGS) provide genome-wide information on cytosine methylation. However, a profiling method that detects cytosine methylation state dispersed over the genome would allow high-throughput analysis of multiple plant samples with distinct epigenetic signatures. We use specific restriction endonucleases to enrich for cytosine coverage in a bisulfite and NGS-based profiling method, which was compared to whole-genome bisulfite sequencing of the same plant material. We established an effective methylome profiling method in plants, termed plant-reduced representation bisulfite sequencing (plant-RRBS), using optimized double restriction endonuclease digestion, fragment end repair, adapter ligation, followed by bisulfite conversion, PCR amplification and NGS. We report a performant laboratory protocol and a straightforward bioinformatics data analysis pipeline for plant-RRBS, applicable for any reference-sequenced plant species. As a proof of concept, methylome profiling was performed using an Oryza sativa ssp. indica pure breeding line and a derived epigenetically altered line (epiline). Plant-RRBS detects methylation levels at tens of millions of cytosine positions deduced from bisulfite conversion in multiple samples. To evaluate the method, the coverage of cytosine positions, the intra-line similarity and the differential cytosine methylation levels between the pure breeding line and the epiline were determined. Plant-RRBS reproducibly covers commonly up to one fourth of the cytosine positions in the rice genome when using MspI-DpnII within a group of five biological replicates of a line. The method predominantly detects cytosine methylation in putative promoter regions and not-annotated regions in rice. Plant-RRBS offers high-throughput and broad, genome-dispersed methylation detection by effective read number generation obtained from reproducibly covered genome fractions using optimized endonuclease combinations, facilitating comparative analyses of multi-sample studies for cytosine methylation and transgenerational stability in experimental material and plant breeding populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hübner, M.; Lang, N.; Röpcke, J.
2015-01-19
Dielectric etching plasma processes for modern interlevel dielectrics become more and more complex by the introduction of new ultra low-k dielectrics. One challenge is the minimization of sidewall damage, while etching ultra low-k porous SiCOH by fluorocarbon plasmas. The optimization of this process requires a deeper understanding of the concentration of the CF{sub 2} radical, which acts as precursor in the polymerization of the etch sample surfaces. In an industrial dielectric etching plasma reactor, the CF{sub 2} radical was measured in situ using a continuous wave quantum cascade laser (cw-QCL) around 1106.2 cm{sup −1}. We measured Doppler-resolved ro-vibrational absorption lines andmore » determined absolute densities using transitions in the ν{sub 3} fundamental band of CF{sub 2} with the aid of an improved simulation of the line strengths. We found that the CF{sub 2} radical concentration during the etching plasma process directly correlates to the layer structure of the etched wafer. Hence, this correlation can serve as a diagnostic tool of dielectric etching plasma processes. Applying QCL based absorption spectroscopy opens up the way for advanced process monitoring and etching controlling in semiconductor manufacturing.« less
NASA Astrophysics Data System (ADS)
Görlitz, Marco; Abratis, Michael; Wiersberg, Thomas
2014-05-01
Online monitoring and sampling of drill mud gas (OLGA) was conducted during standard rotary drilling and core drilling of the INFLUINS borehole EF-FB 1/12 to gain information on the composition of gases and their distribution at depth within the Thuringian Syncline (Germany). The method can help to identify areas of enhanced permeability and/or porosity, open fractures, and other strata associated with gases at depth. The gas-loaded drill mud was continuously degassed in a modified gas-water separator, which was installed in the mud ditch in close distance to the drill mud outlet. The extracted gas phase was pumped in a nearby field laboratory for continuous on-line analysis. First information on the gas composition (H2, He, N2, O2, CO2, CH4, Ar, Kr) was available only few minutes after gas extraction. More than 40 gas samples were taken from the gas line during drilling and pumping tests for further laboratory studies. Enhanced concentration of methane, helium, hydrogen and carbon dioxide were detected in drill mud when the drill hole encountered gas-rich strata. Down to a depth of 620 m, the drill mud contained maximum concentration of 55 ppmv He, 1400 ppmv of CH4, 400 ppmv of hydrogen and 1.1 vol-% of CO2. The drilling mud gas composition is linked with the drilled strata. Buntsandstein and Muschelkalk show different formation gas composition and are therefore hydraulically separated. Except for helium, the overall abundance of formation gases in drilling mud is relatively low. We therefore consider the INFLUINS borehole to be dry. The correlation between hydrogen and helium and the relatively high helium abundance rules out any artificial origin of hydrogen and suggest a radiolytic origin of hydrogen. Values CH4/(C2H6/C3H8)
Raman Spectroscopy for In-Line Water Quality Monitoring — Instrumentation and Potential
Li, Zhiyun; Deen, M. Jamal; Kumar, Shiva; Selvaganapathy, P. Ravi
2014-01-01
Worldwide, the access to safe drinking water is a huge problem. In fact, the number of persons without safe drinking water is increasing, even though it is an essential ingredient for human health and development. The enormity of the problem also makes it a critical environmental and public health issue. Therefore, there is a critical need for easy-to-use, compact and sensitive techniques for water quality monitoring. Raman spectroscopy has been a very powerful technique to characterize chemical composition and has been applied to many areas, including chemistry, food, material science or pharmaceuticals. The development of advanced Raman techniques and improvements in instrumentation, has significantly improved the performance of modern Raman spectrometers so that it can now be used for detection of low concentrations of chemicals such as in-line monitoring of chemical and pharmaceutical contaminants in water. This paper briefly introduces the fundamentals of Raman spectroscopy, reviews the development of Raman instrumentations and discusses advanced and potential Raman techniques for in-line water quality monitoring. PMID:25230309
Raman spectroscopy for in-line water quality monitoring--instrumentation and potential.
Li, Zhiyun; Deen, M Jamal; Kumar, Shiva; Selvaganapathy, P Ravi
2014-09-16
Worldwide, the access to safe drinking water is a huge problem. In fact, the number of persons without safe drinking water is increasing, even though it is an essential ingredient for human health and development. The enormity of the problem also makes it a critical environmental and public health issue. Therefore, there is a critical need for easy-to-use, compact and sensitive techniques for water quality monitoring. Raman spectroscopy has been a very powerful technique to characterize chemical composition and has been applied to many areas, including chemistry, food, material science or pharmaceuticals. The development of advanced Raman techniques and improvements in instrumentation, has significantly improved the performance of modern Raman spectrometers so that it can now be used for detection of low concentrations of chemicals such as in-line monitoring of chemical and pharmaceutical contaminants in water. This paper briefly introduces the fundamentals of Raman spectroscopy, reviews the development of Raman instrumentations and discusses advanced and potential Raman techniques for in-line water quality monitoring.
General-Purpose Monitoring during Speech Production
ERIC Educational Resources Information Center
Ries, Stephanie; Janssen, Niels; Dufau, Stephane; Alario, F.-Xavier; Burle, Boris
2011-01-01
The concept of "monitoring" refers to our ability to control our actions on-line. Monitoring involved in speech production is often described in psycholinguistic models as an inherent part of the language system. We probed the specificity of speech monitoring in two psycholinguistic experiments where electroencephalographic activities were…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denton, M.S.; Bostick, W.D.; Dinsmore, S.R.
1978-08-01
We describe a new concept in continuously referenced monitoring of the isoenzyme activities of creatine kinase (EC 2.7.3.2) after liquid-chromatographic separation. After separation on a diethylaminoethyl-Sephacel column, the three isoenzymes of creatine kinase undergo a series of upled enzyme reactions, ultimately resulting in the formation of ultraviolet-detectable NADPH. A major advantage of this detection system is the immobilized-enzyme microreactor (2 x 17 mm), which may be removed and stored refrigerated when not in use. A split-stream configuration allows self-blanking of endogenous ultraviolet-absorbing constituents in authentic sera samples, which would otherwise make definitive diagnosis and quantitation difficult or impossible. This detectionmore » system is applicable to the automated analysis of creatine kinase isoenzymes in the clinical laboratory. 5 figures; 42 references.« less
NASA Astrophysics Data System (ADS)
Catala-Civera, Jose M.; Canos-Marin, Antoni J.; de los Reyes, E.
2000-07-01
Microwave control capabilities have been used to monitor the degradation of polyol, an alcohol composite material commonly used in the footwear industry for polymerization purposes. The liquid flows continuously inside a thin pipe and its desirable properties are altered with time associated to moisture absorption processes. Consequently, variations in the dielectric properties are involved, and they can be detected by permittivity measurements. In this paper, in order to obtain high sensitivity and resolution, a rectangular cavity resonator working at a fixed frequency was designed using as sample holder a rectangular pipe containing the liquid going through. Changes in the liquid modify the original response of the cavity with a non- degraded liquid and these differences have been used to determine the degree of degradation of the material. The final response of the microwave resonator was experimentally validated with measurements in a continuous line.
Aerodyne Research mobile infrared methane monitor
NASA Technical Reports Server (NTRS)
Mcmanus, J. B.; Kebabian, P. L.; Kolb, C. E.
1991-01-01
An improved real-time methane monitor based on infrared absorption of the 3.39 micron line of a HeNe laser is described. Real time in situ measurement of methane has important applications in stratospheric and tropospheric chemistry, especially when high accuracy measurements can be made rapidly, providing fine spatial-scale information. The methane instrument provides 5 ppb resolution in a 1 sec averaging time. A key feature in this instrument is the use of magnetic (Zeeman) broadening to achieve continuous tunability with constant output power over a range of 0.017/cm. The instruments optical absorption path length is 47 m through sampled air held at 50 torr in a multipass cell of the Herriott (off-axis resonator) type. A microprocessor controls laser frequency and amplitude and collects data with minimal operator attention. The instrument recently has been used to measure methane emissions from a variety of natural and artificial terrestrial sources.
Interfaces and thin films as seen by bound electromagnetic waves.
Knoll, W
1998-01-01
This contribution summarizes the use of plasmon surface polaritons and guided optical waves for the characterization of interfaces and thin organic films. After a short introduction to the theoretical background of evanescent wave optics, examples are given that show how this interfacial "light" can be employed to monitor thin coatings at a solid/air or solid/liquid interface. Examples are given for a very sensitive thickness determination of samples ranging from self-assembled monolayers, to multilayer assemblies prepared by the Langmuir/Blodgett/Kuhn technique or by the alternate polyelectrolyte deposition. These are complemented by the demonstration of the potential of the technique to also monitor time-dependent processes in a kinetic mode. Here, we put an emphasis on the combination set-up of surface plasmon optics with electrochemical techniques, allowing for the on-line characterization of various surface functionalization strategies, e.g. for (bio-) sensor purposes.
Advanced Diesel Oil Fuel Processor Development
1986-06-01
water exit 29 sample quencher: gas sample line inlet 30 sample quencher: gas sample line exit 31 sample quencher: cooling water inlet 32 desulfuriser ...exit line 33, 34 desulfurimer 35 heat exchanger: process gas exit (to desulfuriser ) 38 shift reactor inlet (top) 37 shift reactor: cooling air exit
20th century Betula pubescens subsp. czerepanovii tree- and forest lines in Norway.
Bryn, Anders; Potthoff, Kerstin
2017-01-01
Georeferenced tree- and forest line data has a wide range of applications and are increasingly used for e.g. monitoring of climate change impacts and range shift modelling. As part of a research project, registrations of previously re-mapped tree- and forest lines have been georeferenced. The data described in this paper contains 100 re-mapped registrations of Betula pubescens subsp. czerepanovii throughout Norway. All of the re-mapped tree- and forest line localities are georeferenced, elevation and aspect are given, elevational and spatial uncertainty are provided, and the re-mapping methods are explained. The published data weremapped for the first time between 1819 and 1963. The same sites were re-mapped between 1928 and 1996, but have until now been missing spatial coordinates. The entries contain 40 x 2 tree lines and 60 x 2 forest lines, most likely presenting the regionally highest registered tree- and forest lines at the given time. The entire material is stored and available for download through the GBIF server. Previously, the entries have been published in journals or reports, partly in Norwegian or German only. Without the provision of the spatial coordinates, the specific locations have been unknown. The material is now available for modelling and monitoring of tree- and forest line range shifts: The recordings are useful for interpretation of climate change impacts on tree- and forest lines, and the locations of re-mapped tree- and forest lines can be implemented in future monitoring projects. Since the recordings most likely provide the highest registered Betula pubescens subsp. czerepanovii locations within their specific regions, they are probably representing the contemporary physiognomic range limits.
NASA Technical Reports Server (NTRS)
Griffin, Timothy P.; Naylor, Guy R.; Haskell, William D.; Breznik, Greg S.; Mizell, Carolyn A.; Helms, William R.; Voska, N. (Technical Monitor)
2002-01-01
An on-line gas monitoring system was developed to replace the older systems used to monitor for cryogenic leaks on the Space Shuttles before launch. The system uses a mass spectrometer to monitor multiple locations in the process, which allows the system to monitor all gas constituents of interest in a nearly simultaneous manner. The system is fully redundant and meets all requirements for ground support equipment (GSE). This includes ruggedness to withstand launch on the Mobile Launcher Platform (MLP), ease of operation, and minimal operator intervention. The system can be fully automated so that an operator is notified when an unusual situation or fault is detected. User inputs are through personal computer using mouse and keyboard commands. The graphical user for detecting cryogenic leaks, many other gas constituents could be monitored using the Hazardous Gas Detection System (HGDS) 2000.
Laeyendecker, Oliver; Nakigozi, Gertrude; Gallant, Joel E.; Huang, Wei; Hudelson, Sarah E.; Quinn, Thomas C.; Newell, Kevin; Serwadda, David; Gray, Ronald H.; Wawer, Maria J.; Eshleman, Susan H.
2012-01-01
Abstract We analyzed antiretroviral drug susceptibility in HIV-infected adults failing first- and second-line antiretroviral treatment (ART) in Rakai, Uganda. Samples obtained from participants at baseline (pretreatment) and at the time of failure on first-line ART and second-line ART were analyzed using genotypic and phenotypic assays for antiretroviral drug resistance. Test results were obtained from 73 samples from 38 individuals (31 baseline samples, 36 first-line failure samples, and six second-line failure samples). Four (13%) of the 31 baseline samples had mutations associated with resistance to nucleoside or nonnucleoside reverse transcriptase inhibitors (NRTIs and NNRTIs, respectively). Among the 36 first-line failure samples, 31 (86%) had NNRTI resistance mutations and 29 (81%) had lamivudine resistance mutations; only eight (22%) had other NRTI resistance mutations. None of the six individuals failing a second-line protease inhibitor (PI)-based regimen had PI resistance mutations. Six (16%) of the participants had discordant genotypic and phenotypic test results. Genotypic resistance to drugs included in first-line ART regimens was detected prior to treatment and among participants failing first-line ART. PI resistance was not detected in individuals failing second-line ART. Surveillance for transmitted and acquired drug resistance remains a priority for scale-up of ART. PMID:22443282
Tale of two sites: capillary versus arterial blood glucose testing in the operating room.
Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O
2012-04-01
Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a strong positive correlation of .91 between capillary glucose values and arterial values (P < .001) although correlation was less stringent at the hyperglycemic range of values. The R(2) statistic was 84%. Differences in values between capillary and arterial samples would not have altered the diagnosis of hypo- and hyperglycemia using typical thresholds. Capillary samples collected intraoperatively are strongly correlated with arterial samples. Glucose monitoring in the operating room can be safely performed by collecting capillary samples for POCT. However, clinicians should still be cautious when interpreting glucose levels that are high, either by repeating the blood glucose test or by having samples sent to the laboratory. Copyright © 2012 Elsevier Inc. All rights reserved.
Classification of Hot Stars by Disk Variability using Hα Line Emission Characteristics
NASA Astrophysics Data System (ADS)
Hoyt Hannah, Christian; Glennon Fagan, W.; Tycner, Christopher
2018-06-01
The variability associated with circumstellar disks around hot and massive stars has been observed on time scales ranging from less than a day to decades. Variations detected in line emission from circumstellar disks on long time scales are typically attributed to disk-growth and disk-loss events. However, in order to fully describe and model such phenomena, adequate spectroscopic observations over long time scales are needed. In this project, we conduct a comprehensive study that is based on spectra recorded over a 14-year period (2005 to 2018) of roughly 100 B-type stars. Using results from a representative sample of over 20 targets, we illustrate how the Hα emission line, one of the most prominent emission features from circumstellar disks, can be used to monitor the variability associated with these systems. Using high-resolution spectra, we utilize line emission characteristics such as equivalent width, peak strength(s), and line-width to setup a classification scheme that describes different types of variabilities. This in turn can be used to divide the systems in disk-growth, disk-loss, variable and stable categories. With additional numerical disk modeling, the recorded variations based on emission line characteristics can also be used to describe changes in disk temperature and density structure. The aim is to develop a tool to help further our understanding of the processes behind the production and eventual dissipation of the circumstellar disks found in hot stars. This work has been supported by NSF grant AST-1614983.
NASA Astrophysics Data System (ADS)
Pozo Nuñez, Francisco; Chelouche, Doron; Kaspi, Shai; Niv, Saar
2017-09-01
We present the first results of an ongoing variability monitoring program of active galactic nuclei (AGNs) using the 46 cm telescope of the Wise Observatory in Israel. The telescope has a field of view of 1.25^\\circ × 0.84^\\circ and is specially equipped with five narrowband filters at 4300, 5200, 5700, 6200, and 7000 Å to perform photometric reverberation mapping studies of the central engine of AGNs. The program aims to observe a sample of 27 AGNs (V < 17 mag) selected according to tentative continuum and line time delay measurements obtained in previous works. We describe the autonomous operation of the telescope together with the fully automatic pipeline used to achieve high-performance unassisted observations, data reduction, and light curves extraction using different photometric methods. The science verification data presented here demonstrates the performance of the monitoring program in particular for efficiently photometric reverberation mapping of AGNs with additional capabilities to carry out complementary studies of other transient and variable phenomena such as variable stars studies.
NASA Astrophysics Data System (ADS)
Zapotosky, J. E.
1991-08-01
This portion of the report includes monitoring of and data for arthropoda and earthworms; pollinating insects; and small mammals and nesting birds. During the 1990 growing season the ELF antenna was operated more frequently than in prior years. This provides 2 years of intermittent ELF exposure for the biological systems to react to the radiation, one year of very limited exposure and greater exposure in 1990. Arthropod and earthworm sampling was conducted at intervals of two weeks from early May to late October. High voltage transmission lines and magnetic fields have been shown to affect honeybee reproduction, survival, orientation, and nest structure. ELF EM fields could have similar effects on native megachild bees. Changes in cell length, number of cells per nest, number of leaver per cell, orientation of nest entrances, and time to collect a round leaf pierce to cap a cell were monitored. We have not detected significant changes that could be attributed to ELF EM fields. Small mammal and nesting bird biological studies in the western Upper Peninsula of Michigan for the year 1990 are reported.
FFT Deconvultion of Be Star Hα Line Profiles
NASA Astrophysics Data System (ADS)
Austin, S. J.
2005-12-01
We have been monitoring the spectroscopic variability of Be stars using the UCA Fiber Fed Spectrograph. The spectra are 0.8 Angstrom/pixel resolution of the Hα line. The observed line profiles are a convolution of the actual profile and the instrumental profile. A Fast Fourier Transform (FFT) method has been used to deconvolve the observed profiles, given the instrument profile obtained by observing the narrow lines from the HgNe wavelength calibration lamp. The long-term monitoring of the spectroscopic variability of Be stars is crucial for testing the various Be star models. Deconvolved H-α line profiles, velocities, and variability are shown for gamma Cas, delta Sco, chi Oph, eta PsA, 48 Lib, and upsilon Sgr (HD181615). Funding has been provided by the UCA University Research Council and the Arkansas Space Grant Consortium.
Self-monitoring high voltage transmission line suspension insulator
Stemler, Gary E.; Scott, Donald N.
1981-01-01
A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.
REMPI-TOFMS for on-line monitoring and controlling the coffee roasting process
NASA Astrophysics Data System (ADS)
Dorfner, Ralph; Ferge, Thomas; Yeretzian, Chahan; Zimmermann, Ralf; Kettrup, Antonius
2001-08-01
REMPI@266nm-TOFMS is used for on-line analysis of the coffee roasting process. Volatile and flavor active compounds of coffee were ionized by REMPI@266nm and monitored on-line and in real-time by TOFMS during the coffee roasting process. The phenol and 4-vinylguaiacol time-intensity profiles, for example, show typical behavior for different roasting temperatures and provide an indicator to the achieved degree of roasting. The impact of the moisture level of the green coffee beans on the time shift of a typical (commercial) roasting time, correlates with REMPI-TOFMS measurements and literature data.
REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.
DOE Office of Scientific and Technical Information (OSTI.GOV)
FOERSTER,C.
Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas aftermore » a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of {approximately} 1 x 10{sup {minus}10} Torr without beam and {approximately} 1 x 10{sup {minus}9} Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware downstream of front ends. O-ring-sealed valves, if used, are not permitted upstream of the monochromator exit aperture. It will be the responsibility of users to demonstrate that their experiment will not degrade the pressure or quality of the storage ring vacuum. As a matter of operating policy, all beam lines will be monitored for prescribed pressure and the contribution of high mass gases to this pressure each time a beam line has been opened to ring vacuum.« less
Moncrieff, J
1994-03-18
A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.
Active Layer and Moisture Measurements for Intensive Site 0 and 1, Barrow, Alaska
John Peterson
2015-04-17
These are measurements of Active Layer Thickness collected along several lines beginning in September, 2011 to the present. The data were collected at several time periods along the Site0 L2 Line, the Site1 AB Line, and an ERT Monitoring Line near Area A in Site1.
Efficient Bayesian experimental design for contaminant source identification
NASA Astrophysics Data System (ADS)
Zhang, J.; Zeng, L.
2013-12-01
In this study, an efficient full Bayesian approach is developed for the optimal sampling well location design and source parameter identification of groundwater contaminants. An information measure, i.e., the relative entropy, is employed to quantify the information gain from indirect concentration measurements in identifying unknown source parameters such as the release time, strength and location. In this approach, the sampling location that gives the maximum relative entropy is selected as the optimal one. Once the sampling location is determined, a Bayesian approach based on Markov Chain Monte Carlo (MCMC) is used to estimate unknown source parameters. In both the design and estimation, the contaminant transport equation is required to be solved many times to evaluate the likelihood. To reduce the computational burden, an interpolation method based on the adaptive sparse grid is utilized to construct a surrogate for the contaminant transport. The approximated likelihood can be evaluated directly from the surrogate, which greatly accelerates the design and estimation process. The accuracy and efficiency of our approach are demonstrated through numerical case studies. Compared with the traditional optimal design, which is based on the Gaussian linear assumption, the method developed in this study can cope with arbitrary nonlinearity. It can be used to assist in groundwater monitor network design and identification of unknown contaminant sources. Contours of the expected information gain. The optimal observing location corresponds to the maximum value. Posterior marginal probability densities of unknown parameters, the thick solid black lines are for the designed location. For comparison, other 7 lines are for randomly chosen locations. The true values are denoted by vertical lines. It is obvious that the unknown parameters are estimated better with the desinged location.
Fayad, Paul B; Roy-Lachapelle, Audrey; Duy, Sung Vo; Prévost, Michèle; Sauvé, Sébastien
2015-12-15
An analytical method based on on-line SPE-LC-HESI-MS/MS has been developed for the detection and quantification of eight selected cyanotoxins in algal bloom waters that include mycrocystins, anatoxin-a and cylindrospermopsin. The injection volume was 2 mL according to the expected concentration of cyanotoxins in matrix. The method provides an analysis time of 7 min per sample, acceptable recovery values (91-101%), good precision (RSD < 13%) and method limits of detection at the sub-microgram per liter levels (0.01-0.02 μg L(-1)). A detailed discussion on optimization parameters that have an impact on the overall performance of the method are presented. In particular, method optimization permitted the chromatographic separation of anatoxin-a and phenylalanine, an isobaric interference with a similar chromatographic characteristics. All optimization and validation experiments for the on-line SPE method and chromatographic separation were performed in environmentally relevant algal bloom water matrices. The applicability of the method was tested on several algal bloom water samples from monitored lakes across the province of Québec (Québec, Canada) known to produce cyanotoxins. All of the targeted cyanotoxins were detected with the exception of cylindrospermopsin. In addition, it was found that total microcystin concentrations in several surface water samples exceeded the proposed guidelines established by the province of Québec in Canada of 1.5 μg L(-1) as well as the World Health Organization of 1 μg L(-1) for both free and cell-bound microcystin-LR equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.
Laser metrology in food-related systems
NASA Astrophysics Data System (ADS)
Mendoza-Sanchez, Patricia; Lopez, Daniel; Kongraksawech, Teepakorn; Vazquez, Pedro; Torres, J. Antonio; Ramirez, Jose A.; Huerta-Ruelas, Jorge
2005-02-01
An optical system was developed using a low-cost semiconductor laser and commercial optical and electronic components, to monitor food processes by measuring changes in optical rotation (OR) of chiral compounds. The OR signal as a function of processing time and sample temperature were collected and recorded using a computer data acquisition system. System has been tested during two different processes: sugar-protein interaction and, beer fermentation process. To study sugar-protein interaction, the following sugars were used: sorbitol, trehalose and sucrose, and in the place of Protein, Serum Albumin Bovine (BSA, A-7906 Sigma-Aldrich). In some food processes, different sugars are added to protect damage of proteins during their processing, storage and/or distribution. Different sugar/protein solutions were prepared and heated above critical temperature of protein denaturation. OR measurements were performed during heating process and effect of different sugars in protein denaturation was measured. Higher sensitivity of these measurements was found compared with Differential Scanning Calorimetry, which needs higher protein concentration to study these interactions. The brewing fermentation process was monitored in-situ using this OR system and validated by correlation with specific density measurements and gas chromatography. This instrument can be implemented to monitor fermentation on-line, thereby determining end of process and optimizing process conditions in an industrial setting. The high sensitivity of developed OR system has no mobile parts and is more flexible than commercial polarimeters providing the capability of implementation in harsh environments, signifying the potential of this method as an in-line technique for quality control in food processing and for experimentation with optically active solutions.
O'Sullivan, Jeanette E; Watson, Roslyn J; Butler, Edward C V
2013-10-15
An automated procedure including both in-line preconcentration and multi-element determination by an inductively coupled plasma mass spectrometer (ICP-MS) has been developed for the determination of Cd, Co, Cu, Ni, Pb and Zn in open-ocean samples. The method relies on flow injection of the sample through a minicolumn of chelating (iminodiacetate) sorbent to preconcentrate the trace metals, while simultaneously eliminating the major cations and anions of seawater. The effectiveness of this step is tested and reliability in results are secured with a rigorous process of quality assurance comprising 36 calibration and reference samples in a run for analysis of 24 oceanic seawaters in a 6-h program. The in-line configuration and procedures presented minimise analyst operations and exposure to contamination. Seawater samples are used for calibration providing a true matrix match. The continuous automated pH measurement registers that chelation occurs within a selected narrow pH range and monitors the consistency of the entire analytical sequence. The eluent (0.8M HNO3) is sufficiently strong to elute the six metals in 39 s at a flow rate of 2.0 mL/min, while being compatible for prolonged use with the mass spectrometer. Throughput is one sample of 7 mL every 6 min. Detection limits were Co 3.2 pM, Ni 23 pM, Cu 46 pM, Zn 71 pM, Cd 2.7 pM and Pb 1.5 pM with coefficients of variation ranging from 3.4% to 8.6% (n=14) and linearity of calibration established beyond the observed concentration range of each trace metal in ocean waters. Recoveries were Co 96.7%, Ni 102%, Cu 102%, Zn 98.1%, Cd 92.2% and Pb 97.6%. The method has been used to analyse ~800 samples from three voyages in the Southern Ocean and Tasman Sea. It has the potential to be extended to other trace elements in ocean waters. © 2013 Elsevier B.V. All rights reserved.
Umesh, Goneppanavar; Jasvinder, Kaur; Shetty, Nanda
2009-08-01
Heat and moisture exchangers (HME) are commonly used during general anaesthesia and intensive care of patients on mechanical ventilators. Some of the HME manufacturers provide HMEs with a Luer lock fitting for connecting side stream CO(2) monitoring line, Luer lock cap, and a non-threaded cap mount. However, HMEs from different manufacturers and HMEs meant for use in children and for adults from the same manufacturer vary in the presence/absence of non-threaded cap mount. This can create confusion to the clinicians and can result in inadvertent connection of the CO(2) monitoring line to the non-threaded cap mount resulting in blocked CO(2) monitoring line and leak in the circuit. We caution all the anaesthesiologists and intensivists regarding this possibility while using HMEs from different manufacturers.
Dynamic laser speckle analyzed considering inhomogeneities in the biological sample
NASA Astrophysics Data System (ADS)
Braga, Roberto A.; González-Peña, Rolando J.; Viana, Dimitri Campos; Rivera, Fernando Pujaico
2017-04-01
Dynamic laser speckle phenomenon allows a contactless and nondestructive way to monitor biological changes that are quantified by second-order statistics applied in the images in time using a secondary matrix known as time history of the speckle pattern (THSP). To avoid being time consuming, the traditional way to build the THSP restricts the data to a line or column. Our hypothesis is that the spatial restriction of the information could compromise the results, particularly when undesirable and unexpected optical inhomogeneities occur, such as in cell culture media. It tested a spatial random approach to collect the points to form a THSP. Cells in a culture medium and in drying paint, representing homogeneous samples in different levels, were tested, and a comparison with the traditional method was carried out. An alternative random selection based on a Gaussian distribution around a desired position was also presented. The results showed that the traditional protocol presented higher variation than the outcomes using the random method. The higher the inhomogeneity of the activity map, the higher the efficiency of the proposed method using random points. The Gaussian distribution proved to be useful when there was a well-defined area to monitor.
Ovchinnikova, Olga S; Van Berkel, Gary J
2010-06-30
An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.
Hindered rotations probed by rare earths in crystals: Er3+ and Tm3+ in BaY2F8
NASA Astrophysics Data System (ADS)
Baraldi, A.; Buffagni, E.; Capelletti, R.; Mazzera, M.; Magnani, N.; Carini, G., Jr.; D'Angelo, G.
2009-10-01
The sharpness of absorption lines induced by crystal-field (CF) transitions of rare earths (RE) can be exploited to disclose the rotational structure usually hidden under the more common broad electronic absorptions. In the present work the effectiveness of such an approach is proved by the analysis of the fine structure (FS) accompanying the Er3+ and Tm3+ CF lines in BaY2F8 single crystals. Sequences of weak, very narrow (0.03-0.1cm-1) , closely spaced (˜0.2-0.8cm-1) lines were monitored in high-resolution (as fine as 0.01cm-1 ), low-temperature (9 K) absorption spectra in the 2000-24000cm-1 range. The FS covers a few cm-1 on both sides of the narrowest among the RE-CF lines and is tightly associated with them, as proved by the amplitude dependence on the RE concentration (in the 0.5-20at.% range) and by linear dichroism measurements. The FS lines vanishing at temperatures as low as 40-60 K and the close spacing suggest that they may be ascribed to the simultaneous excitation of both RE-CF electronic transition and hindered rotation (or libration) mode of RE3+-F- group. The attribution is supported both by the specific structure of the host matrix which allows some F- mobility and by the very small line spacing which is in excellent agreement with the RE3+-F- rotational constant (2B=0.39cm-1) . Complementary specific-heat measurements in the temperature range 1.5-25 K show that Er3+ -doped samples display contributions, in addition to the vibrational one of a pure sample, which scale with the Er3+ concentration. The extra specific heat is interpreted in terms of Schottky anomalies; that peaking at ˜17K accounts for electronic transitions between the lowest sublevels of the I415/2 ground manifold, in agreement with the CF spectroscopy results while those occurring below 3.5 K are consistent with level pairs separated by 0.55 and 0.36cm-1 , in agreement with the FS line spacing.
Pla-Tolós, J; Serra-Mora, P; Hakobyan, L; Molins-Legua, C; Moliner-Martinez, Y; Campins-Falcó, P
2016-11-01
In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-10μg/L for irgarol-1051 and 0.7-10μg/L for diuron. The LODs were 0.015μg/L and 0.2μg/L for irgarol-1051 and diuron, respectively. Precision was also satisfactory (relative standard deviation, RSD<3.5%). The proposed methodology was applied to monitor water samples, taking into account the EQS standards for these compounds. The carbon footprint values for the proposed procedure consolidate the operational efficiency (analytical and environmental performance) of in-tube SPME-CapLC-DAD, in general, and in particular for determining irgarol-1051 and diuron in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Industrial Raman gas sensing for real-time system control
NASA Astrophysics Data System (ADS)
Buric, M.; Mullen, J.; Chorpening, B.; Woodruff, S.
2014-06-01
Opportunities exist to improve on-line process control in energy applications with a fast, non-destructive measurement of gas composition. Here, we demonstrate a Raman sensing system which is capable of reporting the concentrations of numerous species simultaneously with sub-percent accuracy and sampling times below one-second for process control applications in energy or chemical production. The sensor is based upon a hollow-core capillary waveguide with a 300 micron bore with reflective thin-film metal and dielectric linings. The effect of using such a waveguide in a Raman process is to integrate Raman photons along the length of the sample-filled waveguide, thus permitting the acquisition of very large Raman signals for low-density gases in a short time. The resultant integrated Raman signals can then be used for quick and accurate analysis of a gaseous mixture. The sensor is currently being tested for energy applications such as coal gasification, turbine control, well-head monitoring for exploration or production, and non-conventional gas utilization. In conjunction with an ongoing commercialization effort, the researchers have recently completed two prototype instruments suitable for hazardous area operation and testing. Here, we report pre-commercialization testing of those field prototypes for control applications in gasification or similar processes. Results will be discussed with respect to accuracy, calibration requirements, gas sampling techniques, and possible control strategies of industrial significance.
Peed, Lindsay A; Nietch, Christopher T; Kelty, Catherine A; Meckes, Mark; Mooney, Thomas; Sivaganesan, Mano; Shanks, Orin C
2011-07-01
Diffuse sources of human fecal pollution allow for the direct discharge of waste into receiving waters with minimal or no treatment. Traditional culture-based methods are commonly used to characterize fecal pollution in ambient waters, however these methods do not discern between human and other animal sources of fecal pollution making it difficult to identify diffuse pollution sources. Human-associated quantitative real-time PCR (qPCR) methods in combination with low-order headwatershed sampling, precipitation information, and high-resolution geographic information system land use data can be useful for identifying diffuse source of human fecal pollution in receiving waters. To test this assertion, this study monitored nine headwatersheds over a two-year period potentially impacted by faulty septic systems and leaky sanitary sewer lines. Human fecal pollution was measured using three different human-associated qPCR methods and a positive significant correlation was seen between abundance of human-associated genetic markers and septic systems following wet weather events. In contrast, a negative correlation was observed with sanitary sewer line densities suggesting septic systems are the predominant diffuse source of human fecal pollution in the study area. These results demonstrate the advantages of combining water sampling, climate information, land-use computer-based modeling, and molecular biology disciplines to better characterize diffuse sources of human fecal pollution in environmental waters.
Lin, Chitsan; Liou, Naiwei; Chang, Pao-Erh; Yang, Jen-Chin; Sun, Endy
2007-04-01
Although most coke oven research is focused on the emission of polycyclic aromatic hydrocarbons, well-known carcinogens, little has been done on the emission of volatile organic compounds, some of which are also thought to be hazardous to workers and the environment. To profile coke oven gas (COG) emissions, we set up an open-path Fourier transform infrared (OP-FTIR) system on top of a battery of coke ovens at a steel mill located in Southern Taiwan and monitored average emissions in a coke processing area for 16.5 hr. Nine COGs were identified, including ammonia, CO, methane, ethane, ethylene, acetylene, propylene, cyclohexane, and O-xylene. Time series plots indicated that the type of pollutants differed over time, suggesting that different emission sources (e.g., coke pushing, quench tower, etc.) were involved at different times over the study period. This observation was confirmed by the low cross-correlation coefficients of the COGs. It was also found that, with the help of meteorological analysis, the data collected by the OP-FTIR system could be analyzed effectively to characterize differences in the location of sources. Although the traditional single-point samplings of emissions involves sampling various sources in a coke processing area at several different times and is a credible profiling of emissions, our findings strongly suggest that they are not nearly as efficient or as cost-effective as the continuous line average method used in this study. This method would make it easier and cheaper for engineers and health risk assessors to identify and to control fugitive volatile organic compound emissions and to improve environmental health.
NASA Astrophysics Data System (ADS)
Korshunov, G. I.; Afanasev, P. I.; Bulbasheva, I. A.
2017-10-01
The monitoring and survey results of drilling and blasting operations are specified during the development of Afanasyevsky deposit of cement raw materials for a 110 kV electricity power lines structure. Seismic explosion waves and air shock waves were registered in the course of monitoring. The dependency of peak particle velocities on the scaled distance and explosive weight by the delay time was obtained.
NASA Astrophysics Data System (ADS)
Zhao, Yanlin; Yao, Jun; Wang, Mi
2016-07-01
On-line monitoring of crystal size in the crystallization process is crucial to many pharmaceutical and fine-chemical industrial applications. In this paper, a novel method is proposed for the on-line monitoring of the cooling crystallization process of L-glutamic acid (LGA) using electrical impedance spectroscopy (EIS). The EIS method can be used to monitor the growth of crystal particles relying on the presence of an electrical double layer on the charged particle surface and the polarization of double layer under the excitation of alternating electrical field. The electrical impedance spectra and crystal size were measured on-line simultaneously by an impedance analyzer and focused beam reflectance measurement (FBRM), respectively. The impedance spectra were analyzed using the equivalent circuit model and the equivalent circuit elements in the model can be obtained by fitting the experimental data. Two equivalent circuit elements, including capacitance (C 2) and resistance (R 2) from the dielectric polarization of the LGA solution and crystal particle/solution interface, are in relation with the crystal size. The mathematical relationship between the crystal size and the equivalent circuit elements can be obtained by a non-linear fitting method. The function can be used to predict the change of crystal size during the crystallization process.
An innate immune system-mimicking, real-time biosensing of infectious bacteria.
Seo, Sung-Min; Jeon, Jin-Woo; Kim, Tae-Yong; Paek, Se-Hwan
2015-09-07
An animal cell-based biosensor was investigated to monitor bacterial contamination in an unattended manner by mimicking the innate immune response. The cells (RAW 264.7 cell line) were first attached onto the solid surfaces of a 96-well microtiter plate and co-incubated in the culture medium with a sample that might contain bacterial contaminants. As Toll-like receptors were present on the cell membrane surfaces, they acted as a sentinel by binding to pathogen-associated molecular patterns (PAMPs) of any contaminant. Such biological recognition initiates signal transmission along various pathways to produce different proinflammatory mediators, one of which, tumor necrosis factor-α (TNF-α) was measured using an immunosensor. To demonstrate automated bacterium monitoring, a capture antibody specific for TNF-α was immobilized on an optical fiber sensor tip and then used to measure complex formation in a label-free sensor system (e.g., Octet Red). The sensor response time depended significantly on the degree of agitation of the culture medium, controlling the biological recognition and further autocrine/paracrine signaling by cytokines. The response, particularly under non-agitated conditions, was also influenced by the medium volume, revealing a local gradient change of the cytokine concentration and also acidity, caused by bacterial growth near the bottom surfaces. A biosensor system retaining 50 μL medium and not employing agitation could be used for the early detection of bacterial contamination. This novel biosensing model was applied to the real-time monitoring of different bacteria, Shigella sonnei, Staphylococcus aureus, and Listeria monocytogenes. They (<100 CFU mL(-1)) could be detected automatically within the working time. Such analysis was carried out without any manual handling regardless of the bacterial species, suggesting the concept of non-targeted bacterial real-time monitoring. This technique was further applied to real sample testing (e.g., with milk) to exemplify, for example, the food quality control process without using any additional sample pretreatment such as magnetic concentration.
Gilks, Charles F; Walker, A Sarah; Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M
2013-01-01
In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm(3)) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm(3); only 7 (2%) switched with CD4≥250 cells/mm(3), four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm(3) (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm(3) only 11/133 (8%) had VL<400 copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm(3) (p<0.0001). Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold 'tiebreaker' of ≥250 cells/mm(3) for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 'clinical failures' would particularly avoid premature, costly switch to second-line ART.
Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L.; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M.
2013-01-01
Background In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. Methods 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm3) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Results Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm3; only 7 (2%) switched with CD4≥250 cells/mm3, four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm3 (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm3 only 11/133 (8%) had VL<400copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm3 (p<0.0001). Conclusion Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold ‘tiebreaker’ of ≥250 cells/mm3 for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 ‘clinical failures’ would particularly avoid premature, costly switch to second-line ART. PMID:23437399
Mears, Lisa; Stocks, Stuart M; Albaek, Mads O; Sin, Gürkan; Gernaey, Krist V
2017-03-01
A mechanistic model-based soft sensor is developed and validated for 550L filamentous fungus fermentations operated at Novozymes A/S. The soft sensor is comprised of a parameter estimation block based on a stoichiometric balance, coupled to a dynamic process model. The on-line parameter estimation block models the changing rates of formation of product, biomass, and water, and the rate of consumption of feed using standard, available on-line measurements. This parameter estimation block, is coupled to a mechanistic process model, which solves the current states of biomass, product, substrate, dissolved oxygen and mass, as well as other process parameters including k L a, viscosity and partial pressure of CO 2 . State estimation at this scale requires a robust mass model including evaporation, which is a factor not often considered at smaller scales of operation. The model is developed using a historical data set of 11 batches from the fermentation pilot plant (550L) at Novozymes A/S. The model is then implemented on-line in 550L fermentation processes operated at Novozymes A/S in order to validate the state estimator model on 14 new batches utilizing a new strain. The product concentration in the validation batches was predicted with an average root mean sum of squared error (RMSSE) of 16.6%. In addition, calculation of the Janus coefficient for the validation batches shows a suitably calibrated model. The robustness of the model prediction is assessed with respect to the accuracy of the input data. Parameter estimation uncertainty is also carried out. The application of this on-line state estimator allows for on-line monitoring of pilot scale batches, including real-time estimates of multiple parameters which are not able to be monitored on-line. With successful application of a soft sensor at this scale, this allows for improved process monitoring, as well as opening up further possibilities for on-line control algorithms, utilizing these on-line model outputs. Biotechnol. Bioeng. 2017;114: 589-599. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Coast Guard exposure to gasoline, MTBE, and benzene vapors during inspection of tank barges.
Davenport, A C; Glynn, T J; Rhambarose, H
2000-01-01
A field study was conducted June through August 1996 in an attempt to quantify short-term exposure levels to Coast Guard personnel performing routine inspection activities aboard commercial tank barges carrying gasoline. Transfer and fleeting operations were monitored in the ports of Pittsburgh, Pa., Huntington, W.Va., Baton Rouge, La., and Galveston, Tex. A total of 43 personal and 68 area samples were analyzed for benzene and total hydrocarbons as gasoline ("gasoline"). Results can be summarized as follows: Personal exposure to benzene gave 15-min time-weighted-average (TWA) results ranging from <0.10 to 0.50 ppm. Area benzene levels ranged from <0.04 to 170 ppm. Personal monitoring for gasoline revealed a range of <2.0 to 590 mg/m3 with a GM of 23 mg/m3. Area sample results for gasoline ranged from 1.7 to 90,000 mg/m3. Twelve personal samples were collected for methyl-tert butyl ether (MTBE). Only two of these were above the limit of detection and had 15-min time-weighted averages of 22 ppm and 1.3 ppm. Eighteen MTBE area samples ranged in value from <3.0 to 38 ppm. Although none of the personal samples met or exceeded proposed or established short-term exposure standards, many of the area sampling results indicated that a significant risk of acute exposure exists in the vicinity of valves, pressure lines, and connections. This includes anticipated sources such as pressure vent valves as well as unexpected sources resulting from structural deficiencies onboard the vessels. These results further emphasize the value of safe work practices and proper vessel maintenance in controlling exposure to harmful chemicals.
Gómez-Ríos, Germán Augusto; Liu, Chang; Tascon, Marcos; Reyes-Garcés, Nathaly; Arnold, Don W; Covey, Thomas R; Pawliszyn, Janusz
2017-04-04
In recent years, the direct coupling of solid phase microextraction (SPME) and mass spectrometry (MS) has shown its great potential to improve limits of quantitation, accelerate analysis throughput, and diminish potential matrix effects when compared to direct injection to MS. In this study, we introduce the open port probe (OPP) as a robust interface to couple biocompatible SPME (Bio-SPME) fibers to MS systems for direct electrospray ionization. The presented design consisted of minimal alterations to the front-end of the instrument and provided better sensitivity, simplicity, speed, wider compound coverage, and high-throughput in comparison to the LC-MS based approach. Quantitative determination of clenbuterol, fentanyl, and buprenorphine was successfully achieved in human urine. Despite the use of short extraction/desorption times (5 min/5 s), limits of quantitation below the minimum required performance levels (MRPL) set by the world antidoping agency (WADA) were obtained with good accuracy (≥90%) and linearity (R 2 > 0.99) over the range evaluated for all analytes using sample volumes of 300 μL. In-line technologies such as multiple reaction monitoring with multistage fragmentation (MRM 3 ) and differential mobility spectrometry (DMS) were used to enhance the selectivity of the method without compromising analysis speed. On the basis of calculations, once coupled to high throughput, this method can potentially yield preparation times as low as 15 s per sample based on the 96-well plate format. Our results demonstrated that Bio-SPME-OPP-MS efficiently integrates sampling/sample cleanup and atmospheric pressure ionization, making it an advantageous configuration for several bioanalytical applications, including doping in sports, in vivo tissue sampling, and therapeutic drug monitoring.
Lamsal, Ram P; Beauchemin, Diane
2015-03-31
A previously developed, efficient and simple on-line leaching method was used to assess the maximum bio-accessible fraction (assuming no synergistic effect from other food and beverage) of potentially toxic elements (Cr, As, Cd and Pb) in whole wheat brown and white bread samples. Artificial saliva, gastric juice and intestinal juice were successively pumped into a mini-column, packed with bread (maintained at 37 °C) connected on-line to the nebulizer of an inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a collision-reaction interface (CRI) using hydrogen as reaction gas to minimize carbon- and chlorine-based polyatomic interferences. In contrast to the conventional batch method to which it was compared, this approach provides real-time monitoring of potentially toxic elements that are continuously released during leaching. Mass balance for both methods was verified at the 95% confidence level. Results obtained from the whole wheat brown and white bread showed that the majority of Cr, Cd and Pb was leached by gastric juice but, in contrast, the majority of As was leached by saliva. While there was higher total content for elements in whole wheat bread than in white bread, a higher percentage of elements were bio-accessible in white bread than in whole wheat bread. Both the on-line and batch methods indicate that 40-98% of toxic elements in bread samples are bio-accessible. While comparison of total analyte concentrations with provisional tolerable daily intake values may indicate some serious health concern for children, when accounting for the bio-accessibility of these elements, bread consumption is found to be safe for all ages. Copyright © 2015 Elsevier B.V. All rights reserved.
Xu, Sihong; Song, Aijing; Nie, Jianhui; Li, Xiuhua; Li, Jingyun; Bao, Zuoyi; Wang, Youchun
2008-11-01
In the present study, 277 clinical samples from untreated and treated HIV-1-infected patients with different clades were used to assess the agreement between the COBAS AmpliPrep/COBAS TaqMan HIV-1 test (CAP/CTM) and VERSANT HIV-1 RNA 3.0 Assay (bDNA). A qualitative comparison of the results of the two assays showed concordance for 255 positive and 15 negative samples (94.95%, kappa = 0.798). However, seven samples with viral loads close to the lower limit of detection for CAP/CTM were negative by bDNA. A significant correlation (r = 0.881, p < 0.001) was observed for 253 samples with viral loads within the dynamic ranges of the two assays, and Bland-Altman analysis showed good agreement (96.05%) between the two assays for these 253 samples [mean (+/-2 SD), 0.389(-0.385, 1.163)]. Furthermore, ART drugs had no impact on the performances of the two assays. For samples with different clades predominant in China, the fitted regression line differed significantly from the line of equality, although significant correlations (r = 0.850-0.891, p < 0.001) and good agreements (92.86-97.25%) were found for the two assays. The mean differences for clade B' and BC samples were significant (p < 0.01). Good precision for clade B' samples was achieved for the CAP/CTM (CV: 20.73%) and bDNA (CV: 12.19%) assays. Furthermore, for clades B', BC, and AE, both assays exhibited good linearities (r = 0.9773-0.9998). Thus, the CAP/CTM and bDNA assays could be useful for quantifying HIV-1 RNA in routine clinical samples and monitoring viral loads in treated and untreated HIV-infected patients in China.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McTeer, Jennifer; Morris, Jenny; Wickham, Stephen
Interim storage is an essential component of the waste management lifecycle, providing a safe, secure environment for waste packages awaiting final disposal. In order to be able to monitor and detect change or degradation of the waste packages, storage building or equipment, it is necessary to know the original condition of these components (the 'waste storage system'). This paper presents an approach to establishing the baseline for a waste-storage system, and provides guidance on the selection and implementation of potential base-lining technologies. The approach is made up of two sections; assessment of base-lining needs and definition of base-lining approach. Duringmore » the assessment of base-lining needs a review of available monitoring data and store/package records should be undertaken (if the store is operational). Evolutionary processes (affecting safety functions), and their corresponding indicators, that can be measured to provide a baseline for the waste-storage system should then be identified in order for the most suitable indicators to be selected for base-lining. In defining the approach, identification of opportunities to collect data and constraints is undertaken before selecting the techniques for base-lining and developing a base-lining plan. Base-lining data may be used to establish that the state of the packages is consistent with the waste acceptance criteria for the storage facility and to support the interpretation of monitoring and inspection data collected during store operations. Opportunities and constraints are identified for different store and package types. Technologies that could potentially be used to measure baseline indicators are also reviewed. (authors)« less
Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.
Christensen, Martin
2012-05-01
Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO(2)). The aim of this paper is to put forward the notion that SvO(2) provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO(2). SvO(2) monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO(2) monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO(2)) might be an attractive alternative to SvO(2) because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO(2) is less accurate than SvO(2) and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO(2) and SvO(2) and this is dependent on the presenting disease, in some cases SvO(2) will be significantly lower than ScvO(2). Whilst newer technologies have been developed to continuously measure cardiac output, SvO(2) monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO(2) or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO(2), trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO(2) will be approximately 16% lower. Copyright © 2011 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Audio distribution and Monitoring Circuit
NASA Technical Reports Server (NTRS)
Kirkland, J. M.
1983-01-01
Versatile circuit accepts and distributes TV audio signals. Three-meter audio distribution and monitoring circuit provides flexibility in monitoring, mixing, and distributing audio inputs and outputs at various signal and impedance levels. Program material is simultaneously monitored on three channels, or single-channel version built to monitor transmitted or received signal levels, drive speakers, interface to building communications, and drive long-line circuits.
Reyes, J F García; Barrales, P Ortega; Díaz, A Molina
2005-03-15
A novel, single and robust solid surface fluorescence-based sensing device assembled in a continuous flow system has been developed for the determination of trace amounts of aluminium in water samples. The proposed method is based on the transient immobilization of the target species on an appropriate active solid sensing zone (C(18) silica gel). The target species was the fluorogenic chelate, formed as a result of the on-line complexation of Al(III) with chromotropic acid (CA) at pH 4.1. The fluorescence of the complex is continuously monitored at an emission wavelength of 390nm upon excitation at 361nm. The instrumental, chemical and flow-injection variables affecting the fluorescence signal were carefully investigated and optimized. After selecting the most suitable conditions, the sensing system was calibrated in the range 10-500mugl(-1), obtaining a detection limit of 2.6mugl(-1), and a R.S.D. of 2.2%, with a sampling frequency of 24h(-1). In addition, the selectivity of the proposed methodology was evaluated by performing interference studies with different cations and anions which could affect the analytical response. Finally, the proposed method, which meets the EU regulations regarding the aluminium content in drinking waters, was satisfactorily applied to different water samples, with recoveries between 97 and 105%. The simplicity, low cost and easy operation are the main advantages of the present procedure.
Cloud-point detection using a portable thickness shear mode crystal resonator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mansure, A.J.; Spates, J.J.; Germer, J.W.
1997-08-01
The Thickness Shear Mode (TSM) crystal resonator monitors the crude oil by propagating a shear wave into the oil. The coupling of the shear wave and the crystal vibrations is a function of the viscosity of the oil. By driving the crystal with circuitry that incorporates feedback, it is possible to determine the change from Newtonian to non-Newtonian viscosity at the cloud point. A portable prototype TSM Cloud Point Detector (CPD) has performed flawlessly during field and lab tests proving the technique is less subjective or operator dependent than the ASTM standard. The TSM CPD, in contrast to standard viscositymore » techniques, makes the measurement in a closed container capable of maintaining up to 100 psi. The closed container minimizes losses of low molecular weight volatiles, allowing samples (25 ml) to be retested with the addition of chemicals. By cycling/thermal soaking the sample, the effects of thermal history can be investigated and eliminated as a source of confusion. The CPD is portable, suitable for shipping the field offices for use by personnel without special training or experience in cloud point measurements. As such, it can make cloud point data available without the delays and inconvenience of sending samples to special labs. The crystal resonator technology can be adapted to in-line monitoring of cloud point and deposition detection.« less
Louiz, I; Kinani, S; Gouze, M-E; Ben-Attia, M; Menif, D; Bouchonnet, S; Porcher, J M; Ben-Hassine, O K; Aït-Aïssa, S
2008-09-01
We used an array of in vitro cell-based bioassays to assess dioxin-like, estrogenic and (anti-)androgenic activities in organic extracts of sediments from the Bizerta lagoon, one of the largest Tunisian lagoons subjected to various anthropogenic and industrial pressures. The sediments were sampled both in winter and summer 2006 in 6 stations differently impacted and in one reference station located in the seawards entrance of Ghar el Melh lagoon. Chemical analyses of the 16 priority PAHs showed that the sediments were low to moderately contaminated (2-537 ng/g dry weight). By using the estrogen- (MELN) and androgen-responsive (MDA-kb2) reporter cell lines, significant estrogenic and anti-androgenic activities were detected only in the Menzel Bourguiba (MB) site, the most contaminated site, both in winter and summer. By using 7-ethoxyresorufin-O-deethylase (EROD) induction in the fish PLHC-1 cell line after both 4 and 24 h of cell exposure, dioxin-like activities were detected in all analysed samples. Dioxin-like activities were higher after 4 h exposure, and varied according to the sites and the sampling season. While highly significant correlation was observed between bioassay- and chemical analyses-derived toxic equivalents (TEQs), PAHs accounted for only a small part (up to 4%) of the detected biological activities, suggesting that other readily metabolised EROD-inducing compounds were present. This study argues for the use of short time exposure to assess biological TEQs in low contaminated samples and provides new induction equivalent factors (IEF(4h)) for 16 PAHs in the PLHC-1 cell line. Finally, our results stress the need to further characterise the nature of organic chemical contamination as well as its long-term impacts on aquatic wildlife in the Bizerta lagoon.
Physiologic monitoring. A guide to networking your monitoring systems.
2011-10-01
There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.
Once Established, What Techniques Work Best for Monitoring the District?
ERIC Educational Resources Information Center
Triverio, Louis E.
Monitoring school budget expenditures is as important as budgeting. School boards should decide which broad financial policies will provide control of expenditures, what financial tools to use in monitoring expenditures, and what areas outside of the budget should be monitored. A board's financial policy ought to deal with the line item transfers,…
Differences in soil quality between organic and conventional farming over a maize crop season
NASA Astrophysics Data System (ADS)
Ferreira, Carla; Veiga, Adelcia; Puga, João; Kikuchi, Ryunosuke; Ferreira, António
2017-04-01
Land degradation in agricultural areas is a major concern. The large number of mechanical interventions and the amount of inputs used to assure high crop productivity, such as fertilizers and pesticides, have negative impacts on soil quality and threaten crop productivity and environmental sustainability. Organic farming is an alternative agriculture system, based on organic fertilizers, biological pest control and crop rotation, in order to mitigate soil degradation. Maize is the third most important cereal worldwide, with 2008 million tons produced in 2013 (IGN, 2016). In Portugal, 120000 ha of arable land is devoted to maize production, leading to annual yields of about 930000 ton (INE, 2015). This study investigates soil quality differences in maize farms under organic and conventional systems. The study was carried out in Coimbra Agrarian Technical School (ESAC), in central region of Portugal. ESAC campus comprises maize fields managed under conventional farming - Vagem Grande (32 ha), and organic fields - Caldeirão (12 ha), distancing 2.8 km. Vagem Grande has been intensively used for grain maize production for more than 20 years, whereas Caldeirão was converted to organic farming in 2008, and is being used to select regional maize varieties. The region has a Mediterranean climate. The maize fields have Eutric Fluvisols, with gentle slopes (<3%). In order to assess soil quality, three plots per farm were installed in May 2006, immediately after sowing, and monitored until October 2016, before harvesting, in order to cover all the crop season. Each plot comprises 5 plant lines (˜4 m width) with 20 m length. In order to assure the comparison between both farms, the same maize variety was used (Pigarro) in both fields, with the same compass. Soil samples were collected immediately after sowing. In Vagem Grande distinct soil samples were taken: (i) within plant lines, and (ii) between plant lines, since mineral fertilizers were spread over the field before sowing, and addition fertilizer was applied together with seeds, in plant lines. In Caldeirão, since fertilization was not performed due to weather constrains, soil samples were collected randomly within the plots. Additional soil samples were collected before harvest, in plant lines and between plant lines, in both farms. Surface (0-15 cm) and subsurface (15-30 cm) soil samples were taken. Soil samples were used for texture, pH, organic carbon, Kjeldhal nitrogen, nitrates, ammonia nitrogen, plant available phosphorus and potassium, and exchangeable cations (Ca2+, Mg2+, K+, Na+) analyses. Additional soil samples were also collected with soil ring samplers (137 cm3) for bulk density analyses after sowing. Surface water infiltration was also measured with tension infiltrometer (membrane of 20cm), using different tensions (0 cm, -3cm, -6 cm e -15cm). Decomposition rate and litter stabilisation was assessed over a 3-month period through the Tea Bag Index (Keuskamp et al., 2013). The number and diversity of earthworms were also measured at the surface (0-20cm), through extraction, and at the subsurface (>20cm), using mustard solution.
Surget, Sylvanie; Descamps, Géraldine; Brosseau, Carole; Normant, Vincent; Maïga, Sophie; Gomez-Bougie, Patricia; Gouy-Colin, Nadège; Godon, Catherine; Béné, Marie C; Moreau, Philippe; Le Gouill, Steven; Amiot, Martine; Pellat-Deceunynck, Catherine
2014-06-14
The aim of this study was to evaluate the efficacy of the p53-reactivating drugs RITA and nutlin3a in killing myeloma cells. A large cohort of myeloma cell lines (n = 32) and primary cells (n = 21) was used for this study. This cohort contained cell lines with various TP53 statuses and primary cells with various incidences of deletion of chromosome 17. Apoptosis was evaluated using flow cytometry with Apo2.7 staining of the cell lines or via the loss of the myeloma-specific marker CD138 in primary cells. Apoptosis was further confirmed by the appearance of a subG1 peak and the activation of caspases 3 and 9. Activation of the p53 pathway was monitored using immunoblotting via the expression of the p53 target genes p21, Noxa, Bax and DR5. The involvement of p53 was further studied in 4 different p53-silenced cell lines. Both drugs induced the apoptosis of myeloma cells. The apoptosis that was induced by RITA was not related to the TP53 status of the cell lines or the del17p status of the primary samples (p = 0.52 and p = 0.80, respectively), and RITA did not commonly increase the expression level of p53 or p53 targets (Noxa, p21, Bax or DR5) in sensitive cells. Moreover, silencing of p53 in two TP53(mutated) cell lines failed to inhibit apoptosis that was induced by RITA, which confirmed that RITA-induced apoptosis in myeloma cells was p53 independent. In contrast, apoptosis induced by nutlin3a was directly linked to the TP53 status of the cell lines and primary samples (p < 0.001 and p = 0.034, respectively) and nutlin3a increased the level of p53 and p53 targets in a p53-dependent manner. Finally, we showed that a nutlin3a-induced DR5 increase (≥ 1.2-fold increase) was a specific and sensitive marker (p < 0.001) for a weak incidence of 17p deletion within the samples (≤ 19%). These data show that RITA, in contrast to nutlin3a, effectively induced apoptosis in a subset of MM cells independently of p53. The findings and could be of interest for patients with a 17p deletion, who are resistant to current therapies.
2014-01-01
Background The aim of this study was to evaluate the efficacy of the p53-reactivating drugs RITA and nutlin3a in killing myeloma cells. Methods A large cohort of myeloma cell lines (n = 32) and primary cells (n = 21) was used for this study. This cohort contained cell lines with various TP53 statuses and primary cells with various incidences of deletion of chromosome 17. Apoptosis was evaluated using flow cytometry with Apo2.7 staining of the cell lines or via the loss of the myeloma-specific marker CD138 in primary cells. Apoptosis was further confirmed by the appearance of a subG1 peak and the activation of caspases 3 and 9. Activation of the p53 pathway was monitored using immunoblotting via the expression of the p53 target genes p21, Noxa, Bax and DR5. The involvement of p53 was further studied in 4 different p53-silenced cell lines. Results Both drugs induced the apoptosis of myeloma cells. The apoptosis that was induced by RITA was not related to the TP53 status of the cell lines or the del17p status of the primary samples (p = 0.52 and p = 0.80, respectively), and RITA did not commonly increase the expression level of p53 or p53 targets (Noxa, p21, Bax or DR5) in sensitive cells. Moreover, silencing of p53 in two TP53mutated cell lines failed to inhibit apoptosis that was induced by RITA, which confirmed that RITA-induced apoptosis in myeloma cells was p53 independent. In contrast, apoptosis induced by nutlin3a was directly linked to the TP53 status of the cell lines and primary samples (p < 0.001 and p = 0.034, respectively) and nutlin3a increased the level of p53 and p53 targets in a p53-dependent manner. Finally, we showed that a nutlin3a-induced DR5 increase (≥1.2-fold increase) was a specific and sensitive marker (p < 0.001) for a weak incidence of 17p deletion within the samples (≤19%). Conclusion These data show that RITA, in contrast to nutlin3a, effectively induced apoptosis in a subset of MM cells independently of p53. The findings and could be of interest for patients with a 17p deletion, who are resistant to current therapies. PMID:24927749
NASA Technical Reports Server (NTRS)
Briggs, Ryan M.; Frez, Clifford; Forouhar, Siamak; May, Randy D.; Ruff, Gary A.
2013-01-01
The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.
Scatena, Caroline D; Hepner, Mischa A; Oei, Yoko A; Dusich, Joan M; Yu, Shang-Fan; Purchio, Tony; Contag, Pamela R; Jenkins, Darlene E
2004-05-15
Animal experiments examining hormone-sensitive metastatic prostate cancer using the human LNCaP cell line have been limited to endpoint analyses. To permit longitudinal studies, we generated a luciferase-expressing cell line and used bioluminescent imaging (BLI) to non-invasively monitor the in vivo growth of primary LNCaP tumors and metastasis. LNCaP.FGC cells were transfected to constitutively express firefly luciferase. LNCaP-luc-M6 cells were tested for bioluminescent signal intensity and hormone responsiveness in vitro. The cells were implanted in subcutaneous and orthotopic sites in SCID-bg mice and imaged over time. The LNCaP-luc-M6 cells formed subcutaneous and orthotopic tumors in SCID-bg mice, and nearly all tumor-bearing animals developed pulmonary metastases. Early detection and temporal growth of primary tumors and metastatic lesions was successfully monitored by BLI. The LNCaP-luc-M6 cell line is a bioluminescent, hormone-sensitive prostate cancer cell line applicable for BLI studies to non-invasively monitor subcutaneous and orthotopic prostate tumor growth and metastasis in vivo. Copyright 2004 Wiley-Liss, Inc.
Superville, Pierre-Jean; Pižeta, Ivanka; Omanović, Dario; Billon, Gabriel
2013-08-15
Based on automatic on-line measurements on the Deûle River that showed daily variation of a peak around -0.56V (vs Ag|AgCl 3M), identification of Reduced Sulphur Species (RSS) in oxic waters was performed applying cathodic stripping voltammetry (CSV) with the hanging mercury drop electrode (HMDE). Pseudopolarographic studies accompanied with increasing concentrations of copper revealed the presence of elemental sulphur S(0), thioacetamide (TA) and reduced glutathione (GSH) as the main sulphur compounds in the Deûle River. In order to resolve these three species, a simple procedure was developed and integrated in an automatic on-line monitoring system. During one week monitoring with hourly measurements, GSH and S(0) exhibited daily cycles whereas no consequential pattern was observed for TA. Copyright © 2013 Elsevier B.V. All rights reserved.
A novel, optical, on-line bacteria sensor for monitoring drinking water quality
Højris, Bo; Christensen, Sarah Christine Boesgaard; Albrechtsen, Hans-Jørgen; Smith, Christian; Dahlqvist, Mathis
2016-01-01
Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been developed. The sensor is based on 3D image recognition, and the obtained pictures are analyzed with algorithms considering 59 quantified image parameters. The sensor counts individual suspended particles and classifies them as either bacteria or abiotic particles. The technology is capable of distinguishing and quantifying bacteria and particles in pure and mixed suspensions, and the quantification correlates with total bacterial counts. Several field applications have demonstrated that the technology can monitor changes in the concentration of bacteria, and is thus well suited for rapid detection of critical conditions such as pollution events in drinking water. PMID:27040142
A novel, optical, on-line bacteria sensor for monitoring drinking water quality.
Højris, Bo; Christensen, Sarah Christine Boesgaard; Albrechtsen, Hans-Jørgen; Smith, Christian; Dahlqvist, Mathis
2016-04-04
Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been developed. The sensor is based on 3D image recognition, and the obtained pictures are analyzed with algorithms considering 59 quantified image parameters. The sensor counts individual suspended particles and classifies them as either bacteria or abiotic particles. The technology is capable of distinguishing and quantifying bacteria and particles in pure and mixed suspensions, and the quantification correlates with total bacterial counts. Several field applications have demonstrated that the technology can monitor changes in the concentration of bacteria, and is thus well suited for rapid detection of critical conditions such as pollution events in drinking water.
Cowen, R.G.
1959-09-29
A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.
WSN-Based Space Charge Density Measurement System
Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong
2017-01-01
It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density. PMID:28052105
WSN-Based Space Charge Density Measurement System.
Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong
2017-01-01
It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.
Using mm-scale seafloor roughness to improve monitoring of macrobenthos by remote sensing
NASA Astrophysics Data System (ADS)
Feldens, Peter; Schönke, Mischa; Wilken, Dennis; Papenmeier, Svenja
2017-04-01
In this study, we determine seafloor roughness at mm-scales by laser line-scanning to improve the remote marine habitat monitoring of macrobenthic organisms. Towards this purpose, a new autonomous lander system has been developed. Remote sensing of the seafloor is required to obtain a comprehensive view of the marine environment. It allows for analyzing spatiotemporal dynamics, monitoring of natural seabed variations, and evaluating possible anthropogenic impacts, all being crucial in regard to marine spatial planning as well as the sustainable and economic use of the sea. One aspect of ongoing remote sensing research is the identification of marine life, including both fauna and flora. The monitoring of seafloor fauna - including benthic communities - is mainly done using optical imaging systems and sample retrieval. The identification of new remote sensing indicator variables characteristic for the physical nature of the respective habitat would allow an improved spatial monitoring. A poorly investigated indicator variable is mm-scale seafloor microtopography and -roughness, which can be measured by laser line scanning and in turn strongly affects acoustic scatter. Two field campaigns have been conducted offshore Sylt Island in 2015 and 2016 to measure the microtopography of seafloor covered by sand masons, blue mussels, and oysters and to collect multi-frequency acoustic data. The acoustic data and topography of the blue mussel and oyster fields are currently being analyzed. The mm-scale microtopography of sand mason covered seafloor were transformed into the frequency domain and the average of the magnitude at different spatial wavelengths was used as a measure of roughness. The presence of sand masons causes a measurable difference in roughness magnitude at spatial wavelengths between 0.02 m and 0.0036 m, with the magnitude depending on sand mason abundance. This effect was not detected by commonly used 1D roughness profiles but required consideration of the complete spectrum. The influenced spatial wavelengths correspond to acoustic frequencies of 75 kHz and 400 kHz that are common for acoustic monitoring purposes. The available results indicate that the development of habitat-specific indicator variables, e.g. related to the abundance of sand masons or mussels, is possible and that remote sensing may assist the monitoring of benthic habitats in the future.
Instruction manual, Optical Effects Module, Model OEM
NASA Technical Reports Server (NTRS)
1975-01-01
The Optical Effects Module Model OEM-1, a laboratory prototype instrument designed for the automated measurement of radiation transmission and scattering through optical samples, is described. The system comprises two main components: the Optical Effects Module Enclosure (OEME) and the Optical Effects Module Electronic Controller and Processor (OEMCP). The OEM is designed for operation in the near UV at approximately 2540A, corresponding to the most intense spectral line activated by the mercury discharge lamp used for illumination. The radiation from this source is detected in transmission and reflection through a number of selectable samples. The basic objective of this operation is to monitor in real time the accretion of possible contamination on the surface of these samples. The optical samples are exposed outside of the OEME proper to define exposure conditions and to separate exposure and measurement environments. Changes in the transmissivity of the sample are attributable to surface contamination or to bulk effects due to radiation. Surface contamination will increase radiation scattering due to Rayleigh-Gans effect or to other phenomena, depending on the characteristics size of the particulate contaminants. Thus, also scattering from the samples becomes a part of the measurement program.
Single-pass BPM system of the Photon Factory storage ring.
Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y
1998-05-01
At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.
NASA Technical Reports Server (NTRS)
Johnson, R. W.; Hall, J. B., Jr.
1977-01-01
Ocean dumping of waste materials is a significant environmental concern in the New York Bight. One of these waste materials, sewage sludge, was monitored in an experiment conducted in the New York Bight on September 22, 1975. Remote sensing over controlled sewage sludge dumping included an 11-band multispectral scanner, fiver multispectral cameras and one mapping camera. Concurrent in situ water samples were taken and acoustical measurements were made of the sewage sludge plumes. Data were obtained for sewage sludge plumes resulting from line (moving barge) and spot (stationary barge) dumps. Multiple aircraft overpasses were made to evaluate temporal effects on the plume signature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Alfonsi; C. Rabiti; D. Mandelli
The Reactor Analysis and Virtual control ENviroment (RAVEN) code is a software tool that acts as the control logic driver and post-processing engine for the newly developed Thermal-Hydraulic code RELAP-7. RAVEN is now a multi-purpose Probabilistic Risk Assessment (PRA) software framework that allows dispatching different functionalities: Derive and actuate the control logic required to simulate the plant control system and operator actions (guided procedures), allowing on-line monitoring/controlling in the Phase Space Perform both Monte-Carlo sampling of random distributed events and Dynamic Event Tree based analysis Facilitate the input/output handling through a Graphical User Interface (GUI) and a post-processing data miningmore » module« less