Sample records for monitor zooming replace

  1. Zoom system without moving element by using two liquid crystal lenses with spherical electrode

    NASA Astrophysics Data System (ADS)

    Yang, Ren-Kai; Lin, Chia-Ping; Su, Guo-Dung J.

    2017-08-01

    A traditional zoom system is composed of several elements moving relatively toward other components to achieve zooming. Unlike tradition system, an electrically control zoom system with liquid crystal (LC) lenses is demonstrated in this paper. To achieve zooming, we apply two LC lenses whose optical power is controlled by voltage to replace two moving lenses in traditional zoom system. The mechanism of zoom system is to use two LC lenses to form a simple zoom system. We found that with such spherical electrodes, we could operate LC lens at voltage range from 31V to 53 V for 3X tunability in optical power. For each LC lens, we use concave spherical electrode which provide lower operating voltage and great tunability in optical power, respectively. For such operating voltage and compact size, this zoom system with zoom ratio approximate 3:1 could be applied to mobile phone, camera and other applications.

  2. 3D display for enhanced tele-operation and other applications

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Pezzaniti, J. Larry; Vaden, Justin; Hyatt, Brian; Morris, James; Chenault, David; Bodenhamer, Andrew; Pettijohn, Bradley; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Kingston, David; Newell, Scott

    2010-04-01

    In this paper, we report on the use of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.

  3. 3D vision upgrade kit for TALON robot

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Pezzaniti, J. Larry; Chenault, David B.; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Pettijohn, Brad

    2010-04-01

    In this paper, we report on the development of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. The 3D vision system was integrated onto a TALON IV Robot and Operator Control Unit (OCU) such that stock components could be electrically disconnected and removed, and upgrade components coupled directly to the mounting and electrical connections. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.

  4. Robust feedback zoom tracking for digital video surveillance.

    PubMed

    Zou, Tengyue; Tang, Xiaoqi; Song, Bao; Wang, Jin; Chen, Jihong

    2012-01-01

    Zoom tracking is an important function in video surveillance, particularly in traffic management and security monitoring. It involves keeping an object of interest in focus during the zoom operation. Zoom tracking is typically achieved by moving the zoom and focus motors in lenses following the so-called "trace curve", which shows the in-focus motor positions versus the zoom motor positions for a specific object distance. The main task of a zoom tracking approach is to accurately estimate the trace curve for the specified object. Because a proportional integral derivative (PID) controller has historically been considered to be the best controller in the absence of knowledge of the underlying process and its high-quality performance in motor control, in this paper, we propose a novel feedback zoom tracking (FZT) approach based on the geometric trace curve estimation and PID feedback controller. The performance of this approach is compared with existing zoom tracking methods in digital video surveillance. The real-time implementation results obtained on an actual digital video platform indicate that the developed FZT approach not only solves the traditional one-to-many mapping problem without pre-training but also improves the robustness for tracking moving or switching objects which is the key challenge in video surveillance.

  5. Robust Feedback Zoom Tracking for Digital Video Surveillance

    PubMed Central

    Zou, Tengyue; Tang, Xiaoqi; Song, Bao; Wang, Jin; Chen, Jihong

    2012-01-01

    Zoom tracking is an important function in video surveillance, particularly in traffic management and security monitoring. It involves keeping an object of interest in focus during the zoom operation. Zoom tracking is typically achieved by moving the zoom and focus motors in lenses following the so-called “trace curve”, which shows the in-focus motor positions versus the zoom motor positions for a specific object distance. The main task of a zoom tracking approach is to accurately estimate the trace curve for the specified object. Because a proportional integral derivative (PID) controller has historically been considered to be the best controller in the absence of knowledge of the underlying process and its high-quality performance in motor control, in this paper, we propose a novel feedback zoom tracking (FZT) approach based on the geometric trace curve estimation and PID feedback controller. The performance of this approach is compared with existing zoom tracking methods in digital video surveillance. The real-time implementation results obtained on an actual digital video platform indicate that the developed FZT approach not only solves the traditional one-to-many mapping problem without pre-training but also improves the robustness for tracking moving or switching objects which is the key challenge in video surveillance. PMID:22969388

  6. Zoom-climb altitude maximization of the F-4C and F-15 aircraft for stratospheric sampling missions

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Merz, A. W.; Page, W. A.

    1976-01-01

    Some predictions indicate that byproducts of aerosol containers may lead to a modification of the ultraviolet-radiation shielding properties of the upper atmosphere. NASA currently monitors atmospheric properties to 70,000 feet using U-2 aircraft. Testing is needed at about 100,000 feet for adequate monitoring of possible aerosol contaminants during the next decade. To study this problem the F-4C and F-15 aircraft were analyzed to determine their maximum altitude ability in zoom-climb maneuvers. These trajectories must satisfy realistic dynamic pressure and Mach number constraints. Maximum altitudes obtained for the F4-C are above 90,000 feet, and for the F-15 above 100,000 feet. Sensitivities of the zoom-climb altitudes were found with respect to several variables including vehicle thrust, initial weight, stratospheric winds and the constraints. A final decision on aircraft selection must be based on mission modification costs and operational considerations balanced against their respective zoom altitude performance capabilities.

  7. Performance of basic manipulation and intracorporeal suturing tasks in a robotic surgical system: single- versus dual-monitor views.

    PubMed

    Shah, Rachit D; Cao, Alex; Golenberg, Lavie; Ellis, R Darin; Auner, Gregory W; Pandya, Abhilash K; Klein, Michael D

    2009-04-01

    Technical advances in the application of laparoscopic and robotic surgical systems have improved platform usability. The authors hypothesized that using two monitors instead of one would lead to faster performance with fewer errors. All tasks were performed using a surgical robot in a training box. One of the monitors was a standard camera with two preset zoom levels (zoomed in and zoomed out, single-monitor condition). The second monitor provided a static panoramic view of the whole surgical field. The standard camera was static at the zoomed-in level for the dual-monitor condition of the study. The study had two groups of participants: 4 surgeons proficient in both robotic and advanced laparoscopic skills and 10 lay persons (nonsurgeons) who were given adequate time to train and familiarize themselves with the equipment. Running a 50-cm rope was the basic task. Advanced tasks included running a suture through predetermined points and intracorporeal knot tying with 3-0 silk. Trial completion times and errors, categorized into three groups (orientation, precision, and task), were recorded. The trial completion times for all the tasks, basic and advanced, in the two groups were not significantly different. Fewer orientation errors occurred in the nonsurgeon group during knot tying (p=0.03) and in both groups during suturing (p=0.0002) in the dual-monitor arm of the study. Differences in precision and task error were not significant. Using two camera views helps both surgeons and lay persons perform complex tasks with fewer errors. These results may be due to better awareness of the surgical field with regard to the location of the instruments, leading to better field orientation. This display setup has potential for use in complex minimally invasive surgeries such as esophagectomy and gastric bypass. This technique also would be applicable to open microsurgery.

  8. An all-silicone zoom lens in an optical imaging system

    NASA Astrophysics Data System (ADS)

    Zhao, Cun-Hua

    2013-09-01

    An all-silicone zoom lens is fabricated. A tunable metal ringer is fettered around the side edge of the lens. A nylon rope linking a motor is tied, encircling the notch in the metal ringer. While the motor is operating, the rope can shrink or release to change the focal length of the lens. A calculation method is developed to obtain the focal length and the zoom ratio. The testing is carried out in succession. The testing values are compared with the calculated ones, and they tally with each other well. Finally, the imaging performance of the all-silicone lens is demonstrated. The all-silicone lens has potential uses in cellphone cameras, notebook cameras, micro monitor lenses, etc.

  9. A methodology for coupling a visual enhancement device to human visual attention

    NASA Astrophysics Data System (ADS)

    Todorovic, Aleksandar; Black, John A., Jr.; Panchanathan, Sethuraman

    2009-02-01

    The Human Variation Model views disability as simply "an extension of the natural physical, social, and cultural variability of mankind." Given this human variation, it can be difficult to distinguish between a prosthetic device such as a pair of glasses (which extends limited visual abilities into the "normal" range) and a visual enhancement device such as a pair of binoculars (which extends visual abilities beyond the "normal" range). Indeed, there is no inherent reason why the design of visual prosthetic devices should be limited to just providing "normal" vision. One obvious enhancement to human vision would be the ability to visually "zoom" in on objects that are of particular interest to the viewer. Indeed, it could be argued that humans already have a limited zoom capability, which is provided by their highresolution foveal vision. However, humans still find additional zooming useful, as evidenced by their purchases of binoculars equipped with mechanized zoom features. The fact that these zoom features are manually controlled raises two questions: (1) Could a visual enhancement device be developed to monitor attention and control visual zoom automatically? (2) If such a device were developed, would its use be experienced by users as a simple extension of their natural vision? This paper details the results of work with two research platforms called the Remote Visual Explorer (ReVEx) and the Interactive Visual Explorer (InVEx) that were developed specifically to answer these two questions.

  10. Eye-gaze determination of user intent at the computer interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, J.H.; Schryver, J.C.

    1993-12-31

    Determination of user intent at the computer interface through eye-gaze monitoring can significantly aid applications for the disabled, as well as telerobotics and process control interfaces. Whereas current eye-gaze control applications are limited to object selection and x/y gazepoint tracking, a methodology was developed here to discriminate a more abstract interface operation: zooming-in or out. This methodology first collects samples of eve-gaze location looking at controlled stimuli, at 30 Hz, just prior to a user`s decision to zoom. The sample is broken into data frames, or temporal snapshots. Within a data frame, all spatial samples are connected into a minimummore » spanning tree, then clustered, according to user defined parameters. Each cluster is mapped to one in the prior data frame, and statistics are computed from each cluster. These characteristics include cluster size, position, and pupil size. A multiple discriminant analysis uses these statistics both within and between data frames to formulate optimal rules for assigning the observations into zooming, zoom-out, or no zoom conditions. The statistical procedure effectively generates heuristics for future assignments, based upon these variables. Future work will enhance the accuracy and precision of the modeling technique, and will empirically test users in controlled experiments.« less

  11. Development of an Intelligent Monitoring and Control System for a Heterogeneous Numerical Propulsion System Simulation

    NASA Technical Reports Server (NTRS)

    Reed, John A.; Afjeh, Abdollah A.; Lewandowski, Henry; Homer, Patrick T.; Schlichting, Richard D.

    1996-01-01

    The NASA Numerical Propulsion System Simulation (NPSS) project is exploring the use of computer simulation to facilitate the design of new jet engines. Several key issues raised in this research are being examined in an NPSS-related research project: zooming, monitoring and control, and support for heterogeneity. The design of a simulation executive that addresses each of these issues is described. In this work, the strategy of zooming, which allows codes that model at different levels of fidelity to be integrated within a single simulation, is applied to the fan component of a turbofan propulsion system. A prototype monitoring and control system has been designed for this simulation to support experimentation with expert system techniques for active control of the simulation. An interconnection system provides a transparent means of connecting the heterogeneous systems that comprise the prototype.

  12. Dynamic calibration of pan-tilt-zoom cameras for traffic monitoring.

    PubMed

    Song, Kai-Tai; Tai, Jen-Chao

    2006-10-01

    Pan-tilt-zoom (PTZ) cameras have been widely used in recent years for monitoring and surveillance applications. These cameras provide flexible view selection as well as a wider observation range. This makes them suitable for vision-based traffic monitoring and enforcement systems. To employ PTZ cameras for image measurement applications, one first needs to calibrate the camera to obtain meaningful results. For instance, the accuracy of estimating vehicle speed depends on the accuracy of camera calibration and that of vehicle tracking results. This paper presents a novel calibration method for a PTZ camera overlooking a traffic scene. The proposed approach requires no manual operation to select the positions of special features. It automatically uses a set of parallel lane markings and the lane width to compute the camera parameters, namely, focal length, tilt angle, and pan angle. Image processing procedures have been developed for automatically finding parallel lane markings. Interesting experimental results are presented to validate the robustness and accuracy of the proposed method.

  13. Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses.

    PubMed

    Riffel, Philipp; Michaely, Henrik J; Morelli, John N; Pfeuffer, Josef; Attenberger, Ulrike I; Schoenberg, Stefan O; Haneder, Stefan

    2014-01-01

    Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI) sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI). 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens) equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens). The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. The pancreas was better delineated in every case (23/23) with z-EPI versus c-EPI. In every case (23/23), both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001) and respiratory motion artifact compared to c-EPI (p<0.0001). Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001). No statistically significant differences in calculated ADC values were observed between the two sequences. Zoomed diffusion-weighted EPI leads to substantial image quality improvements with reduction of susceptibility artifacts in pancreatic DWI.

  14. Enhanced operator perception through 3D vision and haptic feedback

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Light, Kenneth; Bodenhamer, Andrew; Bosscher, Paul; Wilkinson, Loren

    2012-06-01

    Polaris Sensor Technologies (PST) has developed a stereo vision upgrade kit for TALON® robot systems comprised of a replacement gripper camera and a replacement mast zoom camera on the robot, and a replacement display in the Operator Control Unit (OCU). Harris Corporation has developed a haptic manipulation upgrade for TALON® robot systems comprised of a replacement arm and gripper and an OCU that provides haptic (force) feedback. PST and Harris have recently collaborated to integrate the 3D vision system with the haptic manipulation system. In multiple studies done at Fort Leonard Wood, Missouri it has been shown that 3D vision and haptics provide more intuitive perception of complicated scenery and improved robot arm control, allowing for improved mission performance and the potential for reduced time on target. This paper discusses the potential benefits of these enhancements to robotic systems used for the domestic homeland security mission.

  15. SPIDER: Next Generation Chip Scale Imaging Sensor Update

    NASA Astrophysics Data System (ADS)

    Duncan, A.; Kendrick, R.; Ogden, C.; Wuchenich, D.; Thurman, S.; Su, T.; Lai, W.; Chun, J.; Li, S.; Liu, G.; Yoo, S. J. B.

    2016-09-01

    The Lockheed Martin Advanced Technology Center (LM ATC) and the University of California at Davis (UC Davis) are developing an electro-optical (EO) imaging sensor called SPIDER (Segmented Planar Imaging Detector for Electro-optical Reconnaissance) that seeks to provide a 10x to 100x size, weight, and power (SWaP) reduction alternative to the traditional bulky optical telescope and focal-plane detector array. The substantial reductions in SWaP would reduce cost and/or provide higher resolution by enabling a larger-aperture imager in a constrained volume. Our SPIDER imager replaces the traditional optical telescope and digital focal plane detector array with a densely packed interferometer array based on emerging photonic integrated circuit (PIC) technologies that samples the object being imaged in the Fourier domain (i.e., spatial frequency domain), and then reconstructs an image. Our approach replaces the large optics and structures required by a conventional telescope with PICs that are accommodated by standard lithographic fabrication techniques (e.g., complementary metal-oxide-semiconductor (CMOS) fabrication). The standard EO payload integration and test process that involves precision alignment and test of optical components to form a diffraction limited telescope is, therefore, replaced by in-process integration and test as part of the PIC fabrication, which substantially reduces associated schedule and cost. This paper provides an overview of performance data on the second-generation PIC for SPIDER developed under the Defense Advanced Research Projects Agency (DARPA)'s SPIDER Zoom research funding. We also update the design description of the SPIDER Zoom imaging sensor and the second-generation PIC (high- and low resolution versions).

  16. Electrically optofluidic zoom system with a large zoom range and high-resolution image.

    PubMed

    Li, Lei; Yuan, Rong-Ying; Wang, Jin-Hui; Wang, Qiong-Hua

    2017-09-18

    We report an electrically controlled optofluidic zoom system which can achieve a large continuous zoom change and high-resolution image. The zoom system consists of an optofluidic zoom objective and a switchable light path which are controlled by two liquid optical shutters. The proposed zoom system can achieve a large tunable focal length range from 36mm to 92mm. And in this tuning range, the zoom system can correct aberrations dynamically, thus the image resolution is high. Due to large zoom range, the proposed imaging system incorporates both camera configuration and telescope configuration into one system. In addition, the whole system is electrically controlled by three electrowetting liquid lenses and two liquid optical shutters, therefore, the proposed system is very compact and free of mechanical moving parts. The proposed zoom system has potential to take place of conventional zoom systems.

  17. Remote-controlled pan, tilt, zoom cameras at Kilauea and Mauna Loa Volcanoes, Hawai'i

    USGS Publications Warehouse

    Hoblitt, Richard P.; Orr, Tim R.; Castella, Frederic; Cervelli, Peter F.

    2008-01-01

    Lists of important volcano-monitoring disciplines usually include seismology, geodesy, and gas geochemistry. Visual monitoring - the essence of volcanology - is usually not mentioned. Yet, observations of the outward appearance of a volcano provide data that is equally as important as that provided by the other disciplines. The eye was almost certainly the first volcano monitoring-tool used by early man. Early volcanology was mostly descriptive and was based on careful visual observations of volcanoes. There is still no substitute for the eye of an experienced volcanologist. Today, scientific instruments replace or augment our senses as monitoring tools because instruments are faster and more sensitive, work tirelessly day and night, keep better records, operate in hazardous environments, do not generate lawsuits when damaged or destroyed, and in most cases are cheaper. Furthermore, instruments are capable of detecting phenomena that are outside the reach of our senses. The human eye is now augmented by the camera. Sequences of timed images provide a record of visual phenomena that occur on and above the surface of volcanoes. Photographic monitoring is a fundamental monitoring tool; image sequences can often provide the basis for interpreting other data streams. Monitoring data are most useful when they are generated and are available for analysis in real-time or near real-time. This report describes the current (as of 2006) system for real-time photograph acquisition and transmission from remote sites on Kilauea and Mauna Loa volcanoes to the U.S. Geological Survey Hawaiian Volcano Observatory (HVO). It also describes how the photographs are archived and analyzed. In addition to providing system documentation for HVO, we hope that the report will prove useful as a practical guide to the construction of a high-bandwidth network for the telemetry of real-time data from remote locations.

  18. Eye-gaze control of the computer interface: Discrimination of zoom intent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, J.H.; Schryver, J.C.

    1993-10-01

    An analysis methodology and associated experiment were developed to assess whether definable and repeatable signatures of eye-gaze characteristics are evident, preceding a decision to zoom-in, zoom-out, or not to zoom at a computer interface. This user intent discrimination procedure can have broad application in disability aids and telerobotic control. Eye-gaze was collected from 10 subjects in a controlled experiment, requiring zoom decisions. The eye-gaze data were clustered, then fed into a multiple discriminant analysis (MDA) for optimal definition of heuristics separating the zoom-in, zoom-out, and no-zoom conditions. Confusion matrix analyses showed that a number of variable combinations classified at amore » statistically significant level, but practical significance was more difficult to establish. Composite contour plots demonstrated the regions in parameter space consistently assigned by the MDA to unique zoom conditions. Peak classification occurred at about 1200--1600 msec. Improvements in the methodology to achieve practical real-time zoom control are considered.« less

  19. Effect of different signal-processing options on speech-in-noise recognition for cochlear implant recipients with the cochlear CP810 speech processor.

    PubMed

    Potts, Lisa G; Kolb, Kelly A

    2014-04-01

    Difficulty understanding speech in the presence of background noise is a common report among cochlear implant (CI) recipients. Several speech-processing options designed to improve speech recognition, especially in noise, are currently available in the Cochlear Nucleus CP810 speech processor. These include adaptive dynamic range optimization (ADRO), autosensitivity control (ASC), Beam, and Zoom. The purpose of this study was to evaluate CI recipients' speech-in-noise recognition to determine which currently available processing option or options resulted in best performance in a simulated restaurant environment. Experimental study with one study group. The independent variable was speech-processing option, and the dependent variable was the reception threshold for sentences score. Thirty-two adult CI recipients. Eight processing options were tested: Beam, Beam + ASC, Beam + ADRO, Beam + ASC + ADRO, Zoom, Zoom + ASC, Zoom + ADRO, and Zoom + ASC + ADRO. Participants repeated Hearing in Noise Test sentences presented at a 0° azimuth, with R-Space restaurant noise presented from a 360° eight-loudspeaker array at 70 dB sound pressure level. A one-way repeated-measures analysis of variance was used to analyze differences in Beam options, Zoom options, and Beam versus Zoom options. Among the Beam options, Beam + ADRO was significantly poorer than Beam only, Beam + ASC, and Beam + ASC + ADRO. A 1.6-dB difference was observed between the best (Beam only) and poorest (Beam + ADRO) options. Among the Zoom options, Zoom only and Zoom + ADRO were significantly poorer than Zoom + ASC. A 2.2-dB difference was observed between the best (Zoom + ASC) and poorest (Zoom only) options. The comparison between Beam and Zoom options showed one significant difference, with Zoom only significantly poorer than Beam only. No significant difference was found between the other Beam and Zoom options (Beam + ASC vs Zoom + ASC, Beam + ADRO vs Zoom + ADRO, and Beam + ASC + ADRO vs Zoom + ASC + ADRO). The best processing option varied across subjects, with an almost equal number of participants performing best with a Beam option (n = 15) compared with a Zoom option (n = 17). There were no significant demographic or audiological moderating variables for any option. The results showed no significant differences between adaptive directionality (Beam) and fixed directionality (Zoom) when ASC was active in the R-Space environment. This finding suggests that noise-reduction processing is extremely valuable in loud semidiffuse environments in which the effectiveness of directional filtering might be diminished. However, there was no significant difference between the Beam-only and Beam + ASC options, which is most likely related to the additional noise cancellation performed by the Beam option (i.e., two-stage directional filtering and noise cancellation). In addition, the processing options with ADRO resulted in the poorest performances. This could be related to how the CI recipients were programmed or the loud noise level used in this study. The best processing option varied across subjects, but the majority performed best with directional filtering (Beam or Zoom) in combination with ASC. Therefore in a loud semidiffuse environment, the use of either Beam + ASC or Zoom + ASC is recommended. American Academy of Audiology.

  20. Expert system for generating initial layouts of zoom systems with multiple moving lens groups

    NASA Astrophysics Data System (ADS)

    Cheng, Xuemin; Wang, Yongtian; Hao, Qun; Sasián, José M.

    2005-01-01

    An expert system is developed for the automatic generation of initial layouts for the design of zoom systems with multiple moving lens groups. The Gaussian parameters of the zoom system are optimized using the damped-least-squares method to achieve smooth zoom cam curves, with the f-number of each lens group in the zoom system constrained to a rational value. Then each lens group is selected automatically from a database according to its range of f-number, field of view, and magnification ratio as it is used in the zoom system. The lens group database is established from the results of analyzing thousands of zoom lens patents. Design examples are given, which show that the scheme is a practical approach to generate starting points for zoom lens design.

  1. Introduction to the development of intraocular lens

    NASA Astrophysics Data System (ADS)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  2. Design and Implementation of a Video-Zoom Driven Digital Audio-Zoom System for Portable Digital Imaging Devices

    NASA Astrophysics Data System (ADS)

    Park, Nam In; Kim, Seon Man; Kim, Hong Kook; Kim, Ji Woon; Kim, Myeong Bo; Yun, Su Won

    In this paper, we propose a video-zoom driven audio-zoom algorithm in order to provide audio zooming effects in accordance with the degree of video-zoom. The proposed algorithm is designed based on a super-directive beamformer operating with a 4-channel microphone system, in conjunction with a soft masking process that considers the phase differences between microphones. Thus, the audio-zoom processed signal is obtained by multiplying an audio gain derived from a video-zoom level by the masked signal. After all, a real-time audio-zoom system is implemented on an ARM-CORETEX-A8 having a clock speed of 600 MHz after different levels of optimization are performed such as algorithmic level, C-code, and memory optimizations. To evaluate the complexity of the proposed real-time audio-zoom system, test data whose length is 21.3 seconds long is sampled at 48 kHz. As a result, it is shown from the experiments that the processing time for the proposed audio-zoom system occupies 14.6% or less of the ARM clock cycles. It is also shown from the experimental results performed in a semi-anechoic chamber that the signal with the front direction can be amplified by approximately 10 dB compared to the other directions.

  3. Research on surface free energy of electrowetting liquid zoom lens

    NASA Astrophysics Data System (ADS)

    Zhao, Cunhua; Lu, Gaoqi; Wei, Daling; Hong, Xinhua; Cui, Dongqing; Gao, Changliu

    2011-08-01

    Zoom imaging systems have the tendencies of miniaturization or complication so the traditional glass / plastic lenses can't meet the needs. Therefore, a new method, liquid lens is put forward which realizes zoom by changing the shape of liquid surface. liquid zoom lenses have many merits such as smaller volume, lighter weight, controlled zoom, faster response, higher transmission, lower energy consumption and so on. Liquid zoom lenses have wide applications in mobile phones, digital cameras and other small imaging system. The electrowetting phenomenon was reviewed firstly and then the influence of the exerted voltage to the contact angle was analysed in electrowetting effect. At last, the surface free energy of cone-type double liquid zoom lens was researched via the energy minimization principle. The research of surface free energy offers important theoretic dependence for designing liquid zoom lens.

  4. Parametric spectro-temporal analyzer (PASTA) for ultrafast optical performance monitoring

    NASA Astrophysics Data System (ADS)

    Zhang, Chi; Wong, Kenneth K. Y.

    2013-12-01

    Ultrafast optical spectrum monitoring is one of the most challenging tasks in observing ultrafast phenomena, such as the spectroscopy, dynamic observation of the laser cavity, and spectral encoded imaging systems. However, conventional method such as optical spectrum analyzer (OSA) spatially disperses the spectrum, but the space-to-time mapping is realized by mechanical rotation of a grating, so are incapable of operating at high speed. Besides the spatial dispersion, temporal dispersion provided by dispersive fiber can also stretches the spectrum in time domain in an ultrafast manner, but is primarily confined in measuring short pulses. In view of these constraints, here we present a real-time spectrum analyzer called parametric spectro-temporal analyzer (PASTA), which is based on the time-lens focusing mechanism. It achieves a 100-MHz frame rate and can measure arbitrary waveforms. For the first time, we observe the dynamic spectrum of an ultrafast swept-source: Fourier domain mode-locked (FDML) laser, and the spectrum evolution of a laser cavity during its stabilizing process. In addition to the basic single-lens structure, the multi-lens configurations (e.g. telescope or wide-angle scope) will provide a versatile operating condition, which can zoom in to achieve 0.05-nm resolution and zoom out to achieve 10-nm observation range, namely 17 times zoom in/out ratio. In view of the goal of achieving spectrum analysis with fine accuracy, PASTA provides a promising path to study the real-time spectrum of some dynamic phenomena and non-repetitive events, with orders of magnitude enhancement in the frame rate over conventional OSAs.

  5. To zoom or not to zoom: do we have enough pixels?

    NASA Astrophysics Data System (ADS)

    Youngworth, Richard N.; Herman, Eric

    2015-09-01

    Common lexicon in imaging systems includes the frequently used term digital zoom. Of course this term is somewhat of a misnomer as there is no actual zooming in such systems. Instead, digital zoom describes the zoom effect that comes with an image rewriting or reprinting that perhaps can be more accurately described as cropping and enlarging an image (a pixel remapping) for viewing. If done properly, users of the overall hybrid digital-optical system do not know the methodology employed. Hence the essential question, pondered and manipulated since the advent of mature digital image science, really becomes "do we have enough pixels to avoid optical zoom." This paper discusses known imaging factors for hybrid digital-optical systems, most notably resolution considerations. The paper is fundamentally about communication, and thereby includes information useful to the greater consumer, technical, and business community who all have an interest in understanding the key technical details that have driven the amazing technology and development of zoom systems.

  6. 12. NBS LOWER ROOM. BEHIND FAR GLASS WALL IS VIDEO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. NBS LOWER ROOM. BEHIND FAR GLASS WALL IS VIDEO TAPE EQUIPMENT AND VOICE INTERCOM EQUIPMENT. THE MONITORS ABOVE GLASS WALL DISPLAY UNDERWATER TEST VIDEO TO CONTROL ROOM. FARTHEST CONSOLE ROW CONTAINS CAMERA SWITCHING, PANNING, TILTING, FOCUSING, AND ZOOMING. MIDDLE CONSOLE ROW CONTAINS TEST CONDUCTOR CONSOLES FOR MONITORING TEST ACTIVITIES AND DATA. THE CLOSEST CONSOLE ROW IS NBS FACILITY CONSOLES FOR TEST DIRECTOR, SAFETY AND QUALITY ASSURANCE REPRESENTATIVES. - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  7. 13. NBS LOWER ROOM. BEHIND FAR GLASS WALL IS VIDEO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. NBS LOWER ROOM. BEHIND FAR GLASS WALL IS VIDEO TAPE EQUIPMENT AND VOICE INTERCOM EQUIPMENT. THE MONITORS ABOVE GLASS WALL DISPLAY UNDERWATER TEST VIDEO TO CONTROL ROOM. FARTHEST CONSOLE ROW CONTAINS CAMERA SWITCHING, PANNING, TILTING, FOCUSING, AND ZOOMING. MIDDLE CONSOLE ROW CONTAINS TEST CONDUCTOR CONSOLES FOR MONITORING TEST ACTIVITIES AND DATA. THE CLOSEST CONSOLE ROW IS NBC FACILITY CONSOLES FOR TEST DIRECTOR, SAFETY AND QUALITY ASSURANCE REPRESENTATIVES. - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL

  8. Design study for a 16x zoom lens system for visible surveillance camera

    NASA Astrophysics Data System (ADS)

    Vella, Anthony; Li, Heng; Zhao, Yang; Trumper, Isaac; Gandara-Montano, Gustavo A.; Xu, Di; Nikolov, Daniel K.; Chen, Changchen; Brown, Nicolas S.; Guevara-Torres, Andres; Jung, Hae Won; Reimers, Jacob; Bentley, Julie

    2015-09-01

    *avella@ur.rochester.edu Design study for a 16x zoom lens system for visible surveillance camera Anthony Vella*, Heng Li, Yang Zhao, Isaac Trumper, Gustavo A. Gandara-Montano, Di Xu, Daniel K. Nikolov, Changchen Chen, Nicolas S. Brown, Andres Guevara-Torres, Hae Won Jung, Jacob Reimers, Julie Bentley The Institute of Optics, University of Rochester, Wilmot Building, 275 Hutchison Rd, Rochester, NY, USA 14627-0186 ABSTRACT High zoom ratio zoom lenses have extensive applications in broadcasting, cinema, and surveillance. Here, we present a design study on a 16x zoom lens with 4 groups (including two internal moving groups), designed for, but not limited to, a visible spectrum surveillance camera. Fifteen different solutions were discovered with nearly diffraction limited performance, using PNPX or PNNP design forms with the stop located in either the third or fourth group. Some interesting patterns and trends in the summarized results include the following: (a) in designs with such a large zoom ratio, the potential of locating the aperture stop in the front half of the system is limited, with ray height variations through zoom necessitating a very large lens diameter; (b) in many cases, the lens zoom motion has significant freedom to vary due to near zero total power in the middle two groups; and (c) we discuss the trade-offs between zoom configuration, stop location, packaging factors, and zoom group aberration sensitivity.

  9. Designing Computer-Based Learning Contents: Influence of Digital Zoom on Attention

    ERIC Educational Resources Information Center

    Glaser, Manuela; Lengyel, Dominik; Toulouse, Catherine; Schwan, Stephan

    2017-01-01

    In the present study, we investigated the role of digital zoom as a tool for directing attention while looking at visual learning material. In particular, we analyzed whether minimal digital zoom functions similarly to a rhetorical device by cueing mental zooming of attention accordingly. Participants were presented either static film clips, film…

  10. Optimization design of periscope type 3X zoom lens design for a five megapixel cellphone camera

    NASA Astrophysics Data System (ADS)

    Sun, Wen-Shing; Tien, Chuen-Lin; Pan, Jui-Wen; Chao, Yu-Hao; Chu, Pu-Yi

    2016-11-01

    This paper presents a periscope type 3X zoom lenses design for a five megapixel cellphone camera. The configuration of optical system uses the right angle prism in front of the zoom lenses to change the optical path rotated by a 90° angle resulting in the zoom lenses length of 6 mm. The zoom lenses can be embedded in mobile phone with a thickness of 6 mm. The zoom lenses have three groups with six elements. The half field of view is varied from 30° to 10.89°, the effective focal length is adjusted from 3.142 mm to 9.426 mm, and the F-number is changed from 2.8 to 5.13.

  11. Zoom in, zoom out.

    PubMed

    Kanter, Rosabeth Moss

    2011-03-01

    Zoom buttons on digital devices let us examine images from many viewpoints. They also provide an apt metaphor for modes of strategic thinking. Some people prefer to see things up close, others from afar. Both perspectives have virtues. But they should not be fixed positions, says Harvard Business School's Kanter. To get a complete picture, leaders need to zoom in and zoom out. A close-in perspective is often found in relationship-intensive settings. It brings details into sharp focus and makes opportunities look large and compelling. But it can have significant downsides. Leaders who prefer to zoom in tend to create policies and systems that depend too much on politics and favors. They can focus too closely on personal status and on turf protection. And they often miss the big picture. When leaders zoom out, they can see events in context and as examples of general trends. They are able to make decisions based on principles. Yet a far-out perspective also has traps. Leaders can be so high above the fray that they don't recognize emerging threats. Having zoomed out to examine all possible routes, they may fail to notice when the moment is right for action on one path. They may also seem too remote and aloof to their staffs. The best leaders can zoom in to examine problems and then zoom out to look for patterns and causes. They don't divide the world into extremes-idiosyncratic or structural, situational or strategic, emotional or contextual. The point is not to choose one over the other but to learn to move across a continuum of perspectives.

  12. Aberration design of zoom lens systems using thick lens modules.

    PubMed

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  13. Ultrathin zoom telescopic objective.

    PubMed

    Li, Lei; Wang, Di; Liu, Chao; Wang, Qiong-Hua

    2016-08-08

    We report an ultrathin zoom telescopic objective that can achieve continuous zoom change and has reduced compact volume. The objective consists of an annular folded lens and three electrowetting liquid lenses. The annular folded lens undertakes the main part of the focal power of the lens system. Due to a multiple-fold design, the optical path is folded in a lens with the thickness of ~1.98mm. The electrowetting liquid lenses constitute a zoom part. Based on the proposed objective, an ultrathin zoom telescopic camera is demonstrated. We analyze the properties of the proposed objective. The aperture of the proposed objective is ~15mm. The total length of the system is ~18mm with a tunable focal length ~48mm to ~65mm. Compared with the conventional zoom telescopic objective, the total length has been largely reduced.

  14. Research on the relation between the contact angle and the interface curvature radius of electrowetting liquid zoom lens

    NASA Astrophysics Data System (ADS)

    Zhao, Cunhua; Liang, Huiqin; Cui, Dongqing; Hong, Xinhua; Wei, Daling; Gao, Changliu

    2011-08-01

    In the ultralight or ultrathin applied domain of zoom lens, the traditional glass / plastic lens is limited for manufacture technology or cost. Therefore, a liquid lens was put forward to solve the problems. The liquid zoom lens has the merits of lower cost, smaller volume, quicker response, lower energy consumption, continuous zoom and higher accuracy. In liquid zoom lens the precise focal length is obtained by the contact angle changing to affect the curvature radius of interface. In our works, the relations of the exerted voltage, the contact angle, the curvature radius and the focal length were researched and accurately calculated. The calculation of the focal length provides an important theoretical basis for instructing the design of liquid zoom lens.

  15. Design, fabrication, and testing of duralumin zoom mirror with variable thickness

    NASA Astrophysics Data System (ADS)

    Hui, Zhao; Xie, Xiaopeng; Xu, Liang; Ding, Jiaoteng; Shen, Le; Liu, Meiying; Gong, Jie

    2016-10-01

    Zoom mirror is a kind of active optical component that can change its curvature radius dynamically. Normally, zoom mirror is used to correct the defocus and spherical aberration caused by thermal lens effect to improve the beam quality of high power solid-state laser since that component was invented. Recently, the probable application of zoom mirror in realizing non-moving element optical zoom imaging in visible band has been paid much attention. With the help of optical leveraging effect, the slightly changed local optical power caused by curvature variation of zoom mirror could be amplified to generate a great alteration of system focal length without moving elements involved in, but in this application the shorter working wavelength and higher surface figure accuracy requirement make the design and fabrication of such a zoom mirror more difficult. Therefore, the key to realize non-moving element optical zoom imaging in visible band lies in zoom mirror which could provide a large enough saggitus variation while still maintaining a high enough surface figure. Although the annular force based actuation could deform a super-thin mirror having a constant thickness to generate curvature variation, it is quite difficult to maintain a high enough surface figure accuracy and this phenomenon becomes even worse when the diameter and the radius-thickness ratio become bigger. In this manuscript, by combing the pressurization based actuation with a variable thickness mirror design, the purpose of obtaining large saggitus variation and maintaining quite good surface figure accuracy at the same time could be achieved. A prototype zoom mirror with diameter of 120mm and central thickness of 8mm is designed, fabricated and tested. Experimental results demonstrate that the zoom mirror having an initial surface figure accuracy superior to 1/50λ could provide at least 21um saggitus variation and after finishing the curvature variation its surface figure accuracy could still be superior to 1/20λ, which proves that the effectiveness of the theoretical design.

  16. Optical zoom system realized by lateral shift of Alvarez freeform lenses

    NASA Astrophysics Data System (ADS)

    Hou, Changlun; Xin, Qing; Zang, Yue

    2018-04-01

    We present and characterize an optical zoom system with lateral movement of an Alvarez freeform lens for imaging. Mathematical analysis for determining the required freeform surfaces is presented, and optical simulations are performed to confirm and refine the expected zooming behavior. A 3 × optical zoom system that was equivalent to a photographic objective lens with focal length ranging from 34.5 to 103.5 mm and field of view ranging from 60 deg to 22.4 deg is developed by using two pairs of Alvarez lenses and conventional aspheric lenses. The optical performances of the Alvarez zoom system are demonstrated experimentally.

  17. Intraocular lens based on double-liquid variable-focus lens.

    PubMed

    Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2014-01-10

    In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.

  18. Continued Development of Expert System Tools for NPSS Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Lewandowski, Henry

    1996-01-01

    The objectives of this grant were to work with previously developed NPSS (Numerical Propulsion System Simulation) tools and enhance their functionality; explore similar AI systems; and work with the High Performance Computing Communication (HPCC) K-12 program. Activities for this reporting period are briefly summarized and a paper addressing the implementation, monitoring and zooming in a distributed jet engine simulation is included as an attachment.

  19. Design of large zoom for visible and infrared optical system in hemisphere space

    NASA Astrophysics Data System (ADS)

    Xing, Yang-guang; Li, Lin; Zhang, Juan

    2018-01-01

    In the field of space optical, the application of advanced optical instruments for related target detection and identification has become an advanced technology in modern optics. In order to complete the task of search in wide field of view and detailed investigation in small field of view, it is inevitable to use the structure of the zoom system to achieve a better observation for important targets. The innovation of this paper lies in using the zoom optical system in space detection, which achieve firstly military needs of searched target in the large field of view and recognized target in the small field of view. At the same time, this paper also completes firstly the design of variable focus optical detection system in the range of hemisphere space, the zoom optical system is working in the range of visible and infrared wavelengths, the perspective angle reaches 360 ° and the zoom ratio of the visible system is up to 15. The visible system has a zoom range of 60-900 mm, a detection band of 0.48-0.70μm, and a F-number of 2.0 to 5.0. The infrared system has a zoom range of 150 900mm, a detection band of 8-12μm, and a F-number of 1.2 to 3.0. The MTF of the visible zoom system is above 0.4 at spatial frequency of 45 lp / mm, and the infrared zoom system is above 0.4 at spatial frequency of 11 lp / mm. The design results show that the system has a good image quality.

  20. Electro-optically actuated liquid-lens zoom

    NASA Astrophysics Data System (ADS)

    Pütsch, O.; Loosen, P.

    2012-06-01

    Progressive miniaturization and mass market orientation denote a challenge to the design of dynamic optical systems such as zoom-lenses. Two working principles can be identified: mechanical actuation and application of active optical components. Mechanical actuation changes the focal length of a zoom-lens system by varying the axial positions of optical elements. These systems are limited in speed and often require complex coupled movements. However, well established optical design approaches can be applied. In contrast, active optical components change their optical properties by varying their physical structure by means of applying external electric signals. An example are liquidlenses which vary their curvatures to change the refractive power. Zoom-lenses benefit from active optical components in two ways: first, no moveable structures are required and second, fast response characteristics can be realized. The precommercial development of zoom-lenses demands simplified and cost-effective system designs. However the number of efficient optical designs for electro-optically actuated zoom-lenses is limited. In this paper, the systematic development of an electro-optically actuated zoom-lens will be discussed. The application of aberration polynomials enables a better comprehension of the primary monochromatic aberrations at the lens elements during a change in magnification. This enables an enhanced synthesis of the system behavior and leads to a simplified zoom-lens design with no moving elements. The change of focal length is achieved only by varying curvatures of targeted integrated electro-optically actuated lenses.

  1. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    PubMed

    Mc Laughlin, Patrick; Neill, Siobhan O; Fanning, Noel; Mc Garrigle, Anne Marie; Connor, Owen J O; Wyse, Gerry; Maher, Michael M

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  2. Toward an improved haptic zooming algorithm for graphical information accessed by individuals who are blind and visually impaired.

    PubMed

    Rastogi, Ravi; Pawluk, Dianne T V

    2013-01-01

    An increasing amount of information content used in school, work, and everyday living is presented in graphical form. Unfortunately, it is difficult for people who are blind or visually impaired to access this information, especially when many diagrams are needed. One problem is that details, even in relatively simple visual diagrams, can be very difficult to perceive using touch. With manually created tactile diagrams, these details are often presented in separate diagrams which must be selected from among others. Being able to actively zoom in on an area of a single diagram so that the details can be presented at a reasonable size for exploration purposes seems a simpler approach for the user. However, directly using visual zooming methods have some limitations when used haptically. Therefore, a new zooming method is proposed to avoid these pitfalls. A preliminary experiment was performed to examine the usefulness of the algorithm compared to not using zooming. The results showed that the number of correct responses improved with the developed zooming algorithm and participants found it to be more usable than not using zooming for exploration of a floor map.

  3. Optimal power distribution for minimizing pupil walk in a 7.5X afocal zoom lens

    NASA Astrophysics Data System (ADS)

    Song, Wanyue; Zhao, Yang; Berman, Rebecca; Bodell, S. Yvonne; Fennig, Eryn; Ni, Yunhui; Papa, Jonathan C.; Yang, Tianyi; Yee, Anthony J.; Moore, Duncan T.; Bentley, Julie L.

    2017-11-01

    An extensive design study was conducted to find the best optimal power distribution and stop location for a 7.5x afocal zoom lens that controls the pupil walk and pupil location through zoom. This afocal zoom lens is one of the three components in a VIS-SWIR high-resolution microscope for inspection of photonic chips. The microscope consists of an afocal zoom, a nine-element objective and a tube lens and has diffraction limited performance with zero vignetting. In this case, the required change in object (sample) size and resolution is achieved by the magnification change of the afocal component. This creates strict requirements for both the entrance and exit pupil locations of the afocal zoom to couple the two sides successfully. The first phase of the design study looked at conventional four group zoom lenses with positive groups in the front and back and the stop at a fixed location outside the lens but resulted in significant pupil walk. The second phase of the design study focused on several promising unconventional four-group power distribution designs with moving stops that minimized pupil walk and had an acceptable pupil location (as determined by the objective and tube lens).

  4. Structural design of off-axis aspheric surface reflective zoom optical system

    NASA Astrophysics Data System (ADS)

    Zhang, Ke; Chang, Jun; Song, Haiping; Niu, Yajun

    2018-01-01

    Designed an off-axis aspheric reflective zoom optical system, and produced a prototype. The system consists of three aspheric reflective lens, the zoom range is 30mm { 90mm. This system gave up the traditional structure of zoom cam, the lens moved using linear guide rail driven by motor, the positioning precision of which was 0.01mm. And introduced the design of support frames of each lens. The practice tests verified the rationality of the prototype structure design.

  5. Bidimensional Lens Systems : A Rational Approach To Group Displacements During Focusing And/Or Zooming

    NASA Astrophysics Data System (ADS)

    Angénieux, J. P. L.

    1987-06-01

    Modern objective lenses for cinematography, television or photography, and particularly zoom lenses, are composed of several groups of lenses which are axially displaced during zooming and/or focusing. The number of these groups has increased recently as well as the complexity of their relative movements and functions. In this paper, we give a short history of zooming and focusing techniques ; we discuss the inconvenience of traditional solutions. We then introduce the concept of bidimensional law. We propose a systematic classification of possible lens-types according to the 4 possible types of group. We finally present a few types of lenses in the form of truth tables and parametered diagrams explaining which groups move and how during focusing and/or zooming.

  6. Holographic zoom system based on spatial light modulator and liquid device

    NASA Astrophysics Data System (ADS)

    Wang, Di; Li, Lei; Liu, Su-Juan; Wang, Qiong-Hua

    2018-02-01

    In this paper, two holographic zoom systems are proposed based on the programmability of spatial light modulator (SLM) and zoom characteristics of liquid lens. An active optical zoom system is proposed in which the zoom module is composed of a liquid lens and an SLM. By controlling the focal lengths of the liquid lens and the encoded digital lens on the SLM, we can change the magnification of an image without mechanical moving parts and keep the output plane stationary. Then a color holographic zoom system based on a liquid lens is proposed. The system processes the color separation of the original object for red, green, and blue components and generated three holograms respectively. A new hologram with specific reconstructed distance can be generated by combing the hologram of the digital lens with the hologram of the image. By controlling the focal lengths of the liquid lens and the encoded digital lens on the SLM, we can change the magnification of the reconstructed image.

  7. User Friendly Real Time Display

    NASA Astrophysics Data System (ADS)

    McCarthy, Denise M.; McCracken, Bill

    1989-02-01

    Real-time viewing of high resolution infrared line scan reconnaissance imagery is greatly facilitated using Honeywell's Real Time Display in conjunction with a D-500 Infrared Reconnaissance System. The Real-Time Display (RTD) provides the capability of on-board review of high resolution infrared imagery using the wide infrared dynamic range of the D-500 infrared receiver to maximum advantage. The scan converter accepts, processes, and displays imagery from four channels of the IR Receiver after formatting by a multiplexer. The scan converter interfaces with a standard RS-170 video monitor. Detailed review and on-board analysis of infrared reconnaissance imagery stored on a videotape is easily accomplished using the many user-friendly features of the RTD. Using a convenient joystick controller, on-screen mode menus, and a moveable cursor, the operator can examine scenes of interest at four different display magnifications using a four step bidirectional zoom. Imagery areas of interest are first noted using the scrolling wide field display mode at 8x reduced display resolution. On noting an area of interest, the imagery can be marked on the tape record for future recovery and a freeze frame mode can be initiated. The operator can then move the cursor to the area of interest and zoom to higher display magnification for 4x, 2x, and lx display resolutions so that the full 4096 x 4096 pixel infrared frame can be matched to the 512 x 512 pixel display frame. At 8x wide field display magnification the full line scanner field of view is displayed at 8x reduced resolution. There are two selectable modes of obtaining this reduced resolution. The operator can use the default method, which averages the signal from an 8 x 8 pixel group, or it is also possible to select the peak signal of the 8 x 8 pixel block to represent the entire block on the display. In this alternate peak-signal display the wide field can be effectively scanned for hot objects which are more likely to be candidate targets. The intermediate 4x and 2x zoom steps are very useful in maintaining operator orientation in examining target clusters and industrial complexes. The four operating modes of the RTD are described and their use to the operator on a typical mission is outlined. Some installation details are given. The RTD as part of a complete D-500 Infrared Linescan Reconnaissance System is now being installed on a Beech 1900 Environmental Control Aircraft to monitor pollution in very sensitive and commercially important marine ecologies. Its application on military reconnaissance missions will allow the normal review of recorded videotape imagery at a ground station immediately after return of the aircraft to base. The areas of highest interest will have been previously marked during the airborne real-time review by the operator. The RTD packages into only two Line Replaceable Units (LRUs), a Scan Converter, and a Control Unit which includes a joystick hand controller. The CRT display is assumed to be part of the aircraft.

  8. The Zoom Lens: A Case Study in Geometrical Optics.

    ERIC Educational Resources Information Center

    Cheville, Alan; Scepanovic, Misa

    2002-01-01

    Introduces a case study on a motion picture company considering the purchase of a newly developed zoom lens in which students act as the engineers designing the zoom lens based on the criteria of company's specifications. Focuses on geometrical optics. Includes teaching notes and classroom management strategies. (YDS)

  9. Intuitive tactile zooming for graphics accessed by individuals who are blind and visually impaired.

    PubMed

    Rastogi, Ravi; Pawluk, T V Dianne; Ketchum, Jessica

    2013-07-01

    One possibility of providing access to visual graphics for those who are visually impaired is to present them tactually: unfortunately, details easily available to vision need to be magnified to be accessible through touch. For this, we propose an "intuitive" zooming algorithm to solve potential problems with directly applying visual zooming techniques to haptic displays that sense the current location of a user on a virtual diagram with a position sensor and, then, provide the appropriate local information either through force or tactile feedback. Our technique works by determining and then traversing the levels of an object tree hierarchy of a diagram. In this manner, the zoom steps adjust to the content to be viewed, avoid clipping and do not zoom when no object is present. The algorithm was tested using a small, "mouse-like" display with tactile feedback on pictures representing houses in a community and boats on a lake. We asked the users to answer questions related to details in the pictures. Comparing our technique to linear and logarithmic step zooming, we found a significant increase in the correctness of the responses (odds ratios of 2.64:1 and 2.31:1, respectively) and usability (differences of 36% and 19%, respectively) using our "intuitive" zooming technique.

  10. Who's Zooming Whom? Attunement to Animation in the Interface.

    ERIC Educational Resources Information Center

    Chui, Michael; Dillon, Andrew

    1997-01-01

    Two controlled experiments examined whether the animated zooming effect accompanying the opening or closing of a folder in the Apple Macintosh graphical user interface aids in the user's perception of which window corresponds to which folder. Results suggest users may become attuned to the informational content of the zooming effect with…

  11. Design of a zoom lens without motorized optical elements

    NASA Astrophysics Data System (ADS)

    Peng, Runling; Chen, Jiabi; Zhu, Cheng; Zhuang, Songlin

    2007-05-01

    A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. Detailed calculations and simulation examples are presented to show that this zoom lens system appears viable as the next-generation zoom lens.

  12. Design of a zoom lens without motorized optical elements.

    PubMed

    Peng, Runling; Chen, Jiabi; Zhu, Cheng; Zhuang, Songlin

    2007-05-28

    A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. Detailed calculations and simulation examples are presented to show that this zoom lens system appears viable as the next-generation zoom lens.

  13. The attentional 'zoom-lens' in 8-month-old infants.

    PubMed

    Ronconi, Luca; Franchin, Laura; Valenza, Eloisa; Gori, Simone; Facoetti, Andrea

    2016-01-01

    The spatial attention mechanisms of orienting and zooming cooperate to properly select visual information from the environment and plan eye movements accordingly. Despite the fact that orienting ability has been extensively studied in infancy, the zooming mechanism--namely, the ability to distribute the attentional resources to a small or large portion of the visual field--has never been tested before. The aim of the present study was to evaluate the attentional zooming abilities of 8-month-old infants. An eye-tracker device was employed to measure the saccadic latencies (SLs) at the onset of a visual target displayed at two eccentricities. The size of the more eccentric target was adjusted in order to counteract the effect of cortical magnification. Before the target display, attentional resources were automatically focused (zoom-in) or spread out (zoom-out) by using a small or large cue, respectively. Two different cue-target intervals were also employed to measure the time course of this attentional mechanism. The results showed that infants' SLs varied as a function of the cue size. Moreover, a clear time course emerged, demonstrating that infants can rapidly adjust the attentional focus size during a pre-saccadic temporal window. These findings could serve as an early marker for neurodevelopmental disorders associated with attentional zooming dysfunction such as autism and dyslexia. © 2015 John Wiley & Sons Ltd.

  14. Teaching Shakespeare in the Digital Age: The eZoomBook Approach

    ERIC Educational Resources Information Center

    Evain, Christine; De Marco, Chris

    2016-01-01

    What collaborative process can teachers offer in order to stimulate their students' reading of and writing on Shakespeare's plays? How can new technologies contribute to facilitating the classroom experience? The eZoomBook (eZB) template was designed for teachers to create and share multi-level digital books called "eZoomBooks" that…

  15. Thales Angenieux: 42 years of cine 35 mm zoom leadership

    NASA Astrophysics Data System (ADS)

    Debize, Jacques

    2004-02-01

    Since the early years of zoom optics, Angenieux has been involved in cine 8 mm, 16 mm and 35 mm. Among more than twenty different zoom lenses, four of them have been milestones in this field, technical progresses being sanctified by two Oscars in 1964 and 1990. From 1960 to 2002 Angenieux has created first the 4 x 35 LA2, the first four times mechanically compensated zoom lens for cine 35 mm in the world, secondary the 10 x 25 T2, the first ten times mechanically compensated zoom lens for cine 35 mm in the world, then the 10 x 25 HR, the top level of quality for its category and finally the 12 x 24 Optimo with all characteristics and performances greatly increased. This leadership has been reached thanks to computers and in-house softwares but also thanks to new manufacturing processes.

  16. Fast dictionary generation and searching for magnetic resonance fingerprinting.

    PubMed

    Jun Xie; Mengye Lyu; Jian Zhang; Hui, Edward S; Wu, Ed X; Ze Wang

    2017-07-01

    A super-fast dictionary generation and searching (DGS) algorithm was developed for MR parameter quantification using magnetic resonance fingerprinting (MRF). MRF is a new technique for simultaneously quantifying multiple MR parameters using one temporally resolved MR scan. But it has a multiplicative computation complexity, resulting in a big burden of dictionary generating, saving, and retrieving, which can easily be intractable for any state-of-art computers. Based on retrospective analysis of the dictionary matching object function, a multi-scale ZOOM like DGS algorithm, dubbed as MRF-ZOOM, was proposed. MRF ZOOM is quasi-parameter-separable so the multiplicative computation complexity is broken into additive one. Evaluations showed that MRF ZOOM was hundreds or thousands of times faster than the original MRF parameter quantification method even without counting the dictionary generation time in. Using real data, it yielded nearly the same results as produced by the original method. MRF ZOOM provides a super-fast solution for MR parameter quantification.

  17. Federal Aviation Administration - Graphic TFR's

    Science.gov Websites

    NAVAJO CITY, NM, Saturday, May 26, 2018 through Tuesday, June 26, 2018 UTC New zoom to 8/4424 05/26/2018 8/4423 ZAB NM HAZARDS QUEEN, NM, Saturday, May 26, 2018 through Tuesday, June 26, 2018 UTC New zoom ZHU TX SECURITY Corpus Christi, TX, Tuesday, May 29, 2018 through Wednesday, May 30, 2018 Local zoom

  18. An Electrically Tunable Zoom System Using Liquid Lenses

    PubMed Central

    Li, Heng; Cheng, Xuemin; Hao, Qun

    2015-01-01

    A four-group stabilized zoom system using two liquid lenses and two fixed lens groups is proposed. We describe the design principle, realization, and the testing of a 5.06:1 zoom system. The realized effective focal length (EFL) range is 6.93 mm to 35.06 mm, and the field of view (FOV) range is 8° to 40°. The system can zoom fast when liquid lens 1’s (L1’s) optical power take the value from 0.0087 mm−1 to 0.0192 mm−1 and liquid lens 2’s (L2’s) optical power take the value from 0.0185 mm−1 to −0.01 mm−1. Response time of the realized zoom system was less than 2.5 ms, and the settling time was less than 15 ms.The analysis of elements’ parameters and the measurement of lens performance not only verify the design principle further, but also show the zooming process by the use of two liquid lenses. The system is useful for motion carriers e.g., robot, ground vehicle, and unmanned aerial vehicles considering that it is fast, reliable, and miniature. PMID:26729124

  19. Creating Catch 22: Zooming in and Zooming out on the Discursive Constructions of Teachers in a News Article

    ERIC Educational Resources Information Center

    Keogh, Jayne; Garrick, Barbara

    2011-01-01

    The media regularly present negative news articles about teachers and teaching. This paper focuses particularly on one such news article. Using reflective analytic practices, first we zoom in to conduct a detailed analysis of the text. We find that complex and contradictory moral categories of teachers are assembled within and through the text. We…

  20. Zoom microscope objective using electrowetting lenses.

    PubMed

    Li, Lei; Wang, Di; Liu, Chao; Wang, Qiong-Hua

    2016-02-08

    We report a zoom microscope objective which can achieve continuous zoom change and correct the aberrations dynamically. The objective consists of three electrowetting liquid lenses and two glass lenses. The magnification is changed by applying voltages on the three electrowetting lenses. Besides, the three electrowetting liquid lenses can play a role to correct the aberrations. A digital microscope based on the proposed objective is demonstrated. We analyzed the properties of the proposed objective. In contrast to the conventional objectives, the proposed objective can be tuned from ~7.8 × to ~13.2 × continuously. For our objective, the working distance is fixed, which means no movement parts are needed to refocus or change its magnification. Moreover, the zoom objective can be dynamically optimized for a wide range of wavelength. Using such an objective, the fabrication tolerance of the optical system is larger than that of a conventional system, which can decrease the fabrication cost. The proposed zoom microscope objective cannot only take place of the conventional objective, but also has potential application in the 3D microscopy.

  1. Solutions on a high-speed wide-angle zoom lens with aspheric surfaces

    NASA Astrophysics Data System (ADS)

    Yamanashi, Takanori

    2012-10-01

    Recent development in CMOS and digital camera technology has accelerated the business and market share of digital cinematography. In terms of optical design, this technology has increased the need to carefully consider pixel pitch and characteristics of the imager. When the field angle at the wide end, zoom ratio, and F-number are specified, choosing an appropriate zoom lens type is crucial. In addition, appropriate power distributions and lens configurations are required. At points near the wide end of a zoom lens, it is known that an aspheric surface is an effective means to correct off-axis aberrations. On the other hand, optical designers have to focus on manufacturability of aspheric surfaces and perform required analysis with respect to the surface shape. Centration errors aside, it is also important to know the sensitivity to aspheric shape errors and their effect on image quality. In this paper, wide angle cine zoom lens design examples are introduced and their main characteristics are described. Moreover, technical challenges are pointed out and solutions are proposed.

  2. ZebraZoom: an automated program for high-throughput behavioral analysis and categorization

    PubMed Central

    Mirat, Olivier; Sternberg, Jenna R.; Severi, Kristen E.; Wyart, Claire

    2013-01-01

    The zebrafish larva stands out as an emergent model organism for translational studies involving gene or drug screening thanks to its size, genetics, and permeability. At the larval stage, locomotion occurs in short episodes punctuated by periods of rest. Although phenotyping behavior is a key component of large-scale screens, it has not yet been automated in this model system. We developed ZebraZoom, a program to automatically track larvae and identify maneuvers for many animals performing discrete movements. Our program detects each episodic movement and extracts large-scale statistics on motor patterns to produce a quantification of the locomotor repertoire. We used ZebraZoom to identify motor defects induced by a glycinergic receptor antagonist. The analysis of the blind mutant atoh7 revealed small locomotor defects associated with the mutation. Using multiclass supervised machine learning, ZebraZoom categorized all episodes of movement for each larva into one of three possible maneuvers: slow forward swim, routine turn, and escape. ZebraZoom reached 91% accuracy for categorization of stereotypical maneuvers that four independent experimenters unanimously identified. For all maneuvers in the data set, ZebraZoom agreed with four experimenters in 73.2–82.5% of cases. We modeled the series of maneuvers performed by larvae as Markov chains and observed that larvae often repeated the same maneuvers within a group. When analyzing subsequent maneuvers performed by different larvae, we found that larva–larva interactions occurred as series of escapes. Overall, ZebraZoom reached the level of precision found in manual analysis but accomplished tasks in a high-throughput format necessary for large screens. PMID:23781175

  3. Common Aperture Techniques for Imaging Electro-Optical Sensors (CATIES).

    DTIC Science & Technology

    1980-02-01

    milliradians ) at the 5.33:1 zoom point. The zoom optics contain five elements with two moveable air -spaced doublets for accomplishing the zoom function...included in the electrical and optical design but due to funding limitations, system safety requirements during the testing phase and lack of long-term...determined during the system testing phase to be conducted by the Air Force. Limited electronic signal processing (split screen and video mix) was

  4. Optical design of laser zoom projective lens with variable total track

    NASA Astrophysics Data System (ADS)

    He, Yulan; Xiao, Xiangguo; Lu, Feng; Li, Yuan; Han, Kunye; Wang, Nanxi; Qiang, Hua

    2017-02-01

    In order to project the laser command information to the proper distance , so a laser zoom projective lens with variable total track optical system is designed in the carrier-based aircraft landing system. By choosing the zoom structure, designing of initial structure with PW solution, correcting and balancing the aberration, a large variable total track with 35 × zoom is carried out. The size of image is invariable that is φ25m, the distance of projective image is variable from 100m to 3500m. Optical reverse design, the spot is less than 8μm, the MTF is near the diffraction limitation, the value of MTF is bigger than 0.4 at 50lp/mm.

  5. Bifocal liquid lens zoom objective for mobile phone applications

    NASA Astrophysics Data System (ADS)

    Wippermann, F. C.; Schreiber, P.; Bräuer, A.; Craen, P.

    2007-02-01

    Miniaturized camera systems are an integral part of today's mobile phones which recently possess auto focus functionality. Commercially available solutions without moving parts have been developed using the electrowetting technology. Here, the contact angle of a drop of a conductive or polar liquid placed on an insulating substrate can be influenced by an electric field. Besides the compensation of the axial image shift due to different object distances, mobile phones with zoom functionality are desired as a next evolutionary step. In classical mechanically compensated zoom lenses two independently driven actuators combined with precision guides are needed leading to a delicate, space consuming and expansive opto-mechanical setup. Liquid lens technology based on the electrowetting effect gives the opportunity to built adaptive lenses without moving parts thus simplifying the mechanical setup. However, with the recent commercially available liquid lens products a completely motionless and continuously adaptive zoom system with market relevant optical performance is not feasible. This is due to the limited change in optical power the liquid lenses can provide and the dispersion of the used materials. As an intermediate step towards a continuously adjustable and motionless zoom lens we propose a bifocal system sufficient for toggling between two effective focal lengths without any moving parts. The system has its mechanical counterpart in a bifocal zoom lens where only one lens group has to be moved. In a liquid lens bifocal zoom two groups of adaptable liquid lenses are required for adjusting the effective focal length and keeping the image location constant. In order to overcome the difficulties in achromatizing the lens we propose a sequential image acquisition algorithm. Here, the full color image is obtained from a sequence of monochrome images (red, green, blue) leading to a simplified optical setup.

  6. Geographic Data Display Implementation

    DTIC Science & Technology

    1977-06-01

    display to be either multiplied or divided by the magnification factor (normally 1.5). The result is a change of extent around the cursor as seen in... Products printer and a 200-card- per-minute card reader with the Interdata 4 (1-4). The 1-4 with its 64K of core is the applications machine connected...storing these values in the CURSTA array. 57 ZOOM IN FUNCTION KEY ZOOM OUT FUNCTION KEY ZMINTP ZMOUTP SET ZOOM OUT MAG FACTOR ZOMTOP SET

  7. Moon illusion and spiral aftereffect: illusions due to the loom-zoom system?

    PubMed

    Hershenson, M

    1982-12-01

    The moon illusion and the spiral aftereffect are illusions in which apparent size and apparent distance vary inversely. Because this relationship is exactly opposite to that predicted by the static size--distance invariance hypothesis, the illusions have been called "paradoxical." The illusions may be understood as products of a loom-zoom system, a hypothetical visual subsystem that, in its normal operation, acts according to its structural constraint, the constancy axiom, to produce perceptions that satisfy the constraints of stimulation, the kinetic size--distance invariance hypothesis. When stimulated by its characteristic stimulus of symmetrical expansion or contraction, the loom-zoom system produces the perception of a rigid object moving in depth. If this system is stimulated by a rotating spiral, a negative motion-aftereffect is produced when rotation ceases. If fixation is then shifted to a fixed-sized disc, the aftereffect process alters perceived distance and the loom-zoom system alters perceived size such that the disc appears to expand and approach or to contract and recede, depending on the direction of rotation of the spiral. If the loom-zoom system is stimulated by a moon-terrain configuration, the equidistance tendency produces a foreshortened perceived distance for the moon as an inverse function of elevation and acts in conjunction with the loom-zoom system to produce the increased perceived size of the moon.

  8. Active optical zoom system

    DOEpatents

    Wick, David V.

    2005-12-20

    An active optical zoom system changes the magnification (or effective focal length) of an optical imaging system by utilizing two or more active optics in a conventional optical system. The system can create relatively large changes in system magnification with very small changes in the focal lengths of individual active elements by leveraging the optical power of the conventional optical elements (e.g., passive lenses and mirrors) surrounding the active optics. The active optics serve primarily as variable focal-length lenses or mirrors, although adding other aberrations enables increased utility. The active optics can either be LC SLMs, used in a transmissive optical zoom system, or DMs, used in a reflective optical zoom system. By appropriately designing the optical system, the variable focal-length lenses or mirrors can provide the flexibility necessary to change the overall system focal length (i.e., effective focal length), and therefore magnification, that is normally accomplished with mechanical motion in conventional zoom lenses. The active optics can provide additional flexibility by allowing magnification to occur anywhere within the FOV of the system, not just on-axis as in a conventional system.

  9. Optical zoom lens module using MEMS deformable mirrors for portable device

    NASA Astrophysics Data System (ADS)

    Lu, Jia-Shiun; Su, Guo-Dung J.

    2012-10-01

    The thickness of the smart phones in today's market is usually below than 10 mm, and with the shrinking of the phone volume, the difficulty of its production of the camera lens has been increasing. Therefore, how to give the imaging device more functionality in the smaller space is one of the interesting research topics for today's mobile phone companies. In this paper, we proposed a thin optical zoom system which is combined of micro-electromechanical components and reflective optical architecture. By the adopting of the MEMS deformable mirrors, we can change their radius of curvature to reach the optical zoom in and zoom out. And because we used the all-reflective architecture, so this system has eliminated the considerable chromatic aberrations in the absence of lenses. In our system, the thickness of the zoom system is about 11 mm. The smallest EFL (effective focal length) is 4.61 mm at a diagonal field angle of 52° and f/# of 5.24. The longest EFL of the module is 9.22 mm at a diagonal field angle of 27.4 with f/# of 5.03.°

  10. Continuous zoom antenna for mobile visible light communication.

    PubMed

    Zhang, Xuebin; Tang, Yi; Cui, Lu; Bai, Tingzhu

    2015-11-10

    In this paper, we design a continuous zoom antenna for mobile visible light communication (VLC). In the design, a right-angle reflecting prism was adopted to fold the space optical path, thus decreasing the antenna thickness. The surface of each lens in the antenna is spherical, and the system cost is relatively low. Simulation results indicated that the designed system achieved the following performance: zoom ratio of 2.44, field of view (FOV) range of 18°-48°, system gain of 16.8, and system size of 18 mm×6  mm. Finally, we established an indoor VLC system model in a room the size of 5  m ×5  m ×3  m and compared the detection results of the zoom antenna and fixed-focus antenna obtained in a multisource communication environment, a mobile VLC environment, and a multiple-input multiple-output communication environment. The simulation results indicated that the continuous zoom antenna could realize large FOV and high gain. Moreover, the system showed improved stability, mobility, and environmental applicability.

  11. An improved apparatus of infrared videopupillography for monitoring pupil size

    NASA Astrophysics Data System (ADS)

    Huang, T.-.; Ko, M.-.; Ouyang, Y.; Chen, Y.-.; Sone, B.-.; Ou-Yang, M.; Chiou, J.-.

    2014-10-01

    The intraocular pressure (IOP) that can diagnose or track glaucoma generally because it is one of the physiology parameters that are associated with glaucoma. But IOP is not easy and consistence to be measured under different measure conditions. Besides, diabetes is associated with diabetic autonomic neuropathy (DAN). Pupil size response might provide an indirect means about neuronal pathways, so the abnormal pupil size may relate with DAN. Hence an infrared videopupillography is needed for tracking glaucoma and exploring the relation between pupil size and DAN. Our previous research proposed an infrared videopupillography to monitoring the pupil size of different light stimulus in dark room. And this portable infrared videopupillography contains a camera, a beam splitter, the visible-light LEDs for stimulating the eyes, and the infrared LEDs for lighting the eyes. It can be mounted on any eyeglass frame. But it can modulate only two dimensions, we cannot zoom in/out the eyes. Moreover, the eye diameter curves were not smooth and jagged because of the light spots, lone eyelashes, and blink. Therefore, we redesign the optical path of our device to have three dimension modulation. Then we can zoom in the eye to increase the eye resolution and to avoid the LED light spots. The light spot could be solved by defining the distance between IR LED and CCD. This device smaller volume and less prices of our previous videopupillography. We hope this new infrared videopupillography proposed in this paper can achieving early detection about autonomic neuropathy in the future.

  12. ZOOM Lite: next-generation sequencing data mapping and visualization software

    PubMed Central

    Zhang, Zefeng; Lin, Hao; Ma, Bin

    2010-01-01

    High-throughput next-generation sequencing technologies pose increasing demands on the efficiency, accuracy and usability of data analysis software. In this article, we present ZOOM Lite, a software for efficient reads mapping and result visualization. With a kernel capable of mapping tens of millions of Illumina or AB SOLiD sequencing reads efficiently and accurately, and an intuitive graphical user interface, ZOOM Lite integrates reads mapping and result visualization into a easy to use pipeline on desktop PC. The software handles both single-end and paired-end reads, and can output both the unique mapping result or the top N mapping results for each read. Additionally, the software takes a variety of input file formats and outputs to several commonly used result formats. The software is freely available at http://bioinfor.com/zoom/lite/. PMID:20530531

  13. Design of a variable-focal-length optical system

    NASA Technical Reports Server (NTRS)

    Ricks, D.; Shannon, R. R.

    1984-01-01

    Requirements to place an entire optical system with a variable focal length ranging from 20 to 200 cm within a overall length somewhat less than 100 cm placed severe restrictions on the design of a zoom lens suitable for use on a comet explorer. The requirements of a wavelength range of 0.4 to 1.0 microns produced even greater limitations on the possibilities for a design that included a catadioptric (using mirrors and glass) front and followed by a zooming refractive portion. Capabilities available commercial zoom lenses as well as patents of optical systems are reviewed. Preliminary designs of the refractive optics zoom lens and the catadioptric system are presented and evaluated. Of the two, the latter probably has the best chance of success, so long as the shortest focal lengths are not really needed.

  14. Windrum: a program for monitoring seismic signals in real time

    NASA Astrophysics Data System (ADS)

    Giudicepietro, Flora

    2017-04-01

    Windrum is a program devote to monitor seismic signals arriving from remote stations in real time. Since 2000, the Osservatorio Vesuviano (INGV) uses the first version of Windrum to monitor the seismic activity of Mt. Vesuvius, Campi Flegrei, Ischia and Stromboli volcano. The program has been also used at the Observatory of Bukittinggi (Indonesia), at the offices of the Italian National Civil Protection, at the COA in Stromboli and at the Civil Protection Center of the municipality of Pozzuoli (Napoli, Italy). In addition, the Osservatorio Vesuviano regularly uses Windrum in educational events such as the Festival of Science in Genova (Italy), FuturoRemoto and other events organized by Città della Scienza in Naples (Italy). The program displays the seismic trace of one station on a monitor, using short packet of data (typically 1 or 2 seconds) received through UTC Internet protocol. The data packets are in Trace_buffer format, a native protocol of Earthworm seismic system that is widely used for the data transmission on Internet. Windrum allows the user to visualize 24 hours of signals, to zoom selected windows of data, in order to estimate the duration Magnitude (Md) of an earthquake, in an intercative way, and to generate graphic images for the web. Moreover, Windrum can exchange Internet messages with other copies of the same program to synchronize actions, such as to zoom the same window of data or mark the beginning of an earthquake on all active monitors simultaneously. Originally, in 2000, Windrum was developed in VB6. I have now developed a new version in VB.net, which goes beyond the obsolescence problems that were appearing. The new version supports the decoding of binary packets received by soket in a more flexible way, allowing the generation of graphic images in different formats. In addition, the new version allows a more flexible layout configuration, suitable for use on large screens with high resolution. Over the past 17 years the use of Windrum for visual analysis of the seismic signals of Vesuvius, Campi Flegrei, Ischia and Stromboli has reduced the detection threshold of the events, allowing a detailed analysis of the seismogram in near real time.

  15. Zoom Reconstruction Tool: Evaluation of Image Quality and Influence on the Diagnosis of Root Fracture.

    PubMed

    Queiroz, Polyane Mazucatto; Santaella, Gustavo Machado; Capelozza, Ana Lúcia Alvares; Rosalen, Pedro Luiz; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2018-04-01

    This study evaluated the image quality and the diagnosis of root fractures when using the Zoom Reconstruction tool (J Morita, Kyoto, Japan). A utility wax phantom with a metal sample inside was used for objective evaluation, and a mandible with 27 single-rooted teeth (with and without obturation and with and without vertical or horizontal fractures) was used for diagnostic evaluation. The images were acquired in 3 protocols: protocol 1, field of view (FOV) of 4 × 4 cm and a voxel size of 0.08 mm; protocol 2, FOV of 10 × 10 cm and a voxel size of 0.2 mm; and protocol 3, Zoom Reconstruction of images from protocol 2 (FOV of 4 × 4 cm and a voxel size of 0.08 mm). The objective evaluation was achieved by measuring the image noise, and the diagnosis of fractures was performed by 3 evaluators. The area under the receiver operating characteristic curve was used to calculate accuracy, and analysis of variance compared the accuracy and image quality of the protocols. Regarding quality, protocol 1 was superior to protocol 2 (P < .0001) and Zoom Reconstruction (P < .0001). Additionally, images of protocol 2 presented less noise than the Zoom Reconstruction image (P < .0001); however, for diagnosis, Zoom Reconstruction was superior in relation to protocol 2 (P = .011) and did not differ from protocol 1 (P = .228) for the diagnosis of a vertical root fracture in filled teeth. The Zoom Reconstruction tool allows better accuracy for vertical root fracture detection in filled teeth, making it possible to obtain a higher-resolution image from a lower-resolution examination without having to expose the patient to more radiation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Synthetic aperture radar correlator phase histories

    NASA Technical Reports Server (NTRS)

    1977-01-01

    This report supplements the design of the following subsystems: (1) zoom azimuth telescope, zooming range from 3X to 6X. (2) range curvature correcting lenses. (3) Sphero-cylindrical shift lens. (4) Auxiliary lenses (tilted cylinder and matching lens).

  17. Zooming in on Landing Site

    NASA Image and Video Library

    2008-05-24

    This animation zooms in on the area on Mars where NASA Phoenix Mars Lander will touchdown on May 25, 2008. The image was taken by the High Resolution Imaging Science Experiment HiRISE camera on NASA Mars Reconnaissance Orbiter.

  18. The zoom lens of attention: Simulating shuffled versus normal text reading using the SWIFT model

    PubMed Central

    Schad, Daniel J.; Engbert, Ralf

    2012-01-01

    Assumptions on the allocation of attention during reading are crucial for theoretical models of eye guidance. The zoom lens model of attention postulates that attentional deployment can vary from a sharp focus to a broad window. The model is closely related to the foveal load hypothesis, i.e., the assumption that the perceptual span is modulated by the difficulty of the fixated word. However, these important theoretical concepts for cognitive research have not been tested quantitatively in eye movement models. Here we show that the zoom lens model, implemented in the SWIFT model of saccade generation, captures many important patterns of eye movements. We compared the model's performance to experimental data from normal and shuffled text reading. Our results demonstrate that the zoom lens of attention might be an important concept for eye movement control in reading. PMID:22754295

  19. Joint demosaicking and zooming using moderate spectral correlation and consistent edge map

    NASA Astrophysics Data System (ADS)

    Zhou, Dengwen; Dong, Weiming; Chen, Wengang

    2014-07-01

    The recently published joint demosaicking and zooming algorithms for single-sensor digital cameras all overfit the popular Kodak test images, which have been found to have higher spectral correlation than typical color images. Their performance perhaps significantly degrades on other datasets, such as the McMaster test images, which have weak spectral correlation. A new joint demosaicking and zooming algorithm is proposed for the Bayer color filter array (CFA) pattern, in which the edge direction information (edge map) extracted from the raw CFA data is consistently used in demosaicking and zooming. It also moderately utilizes the spectral correlation between color planes. The experimental results confirm that the proposed algorithm produces an excellent performance on both the Kodak and McMaster datasets in terms of both subjective and objective measures. Our algorithm also has high computational efficiency. It provides a better tradeoff among adaptability, performance, and computational cost compared to the existing algorithms.

  20. An autonomous sensor module based on a legacy CCTV camera

    NASA Astrophysics Data System (ADS)

    Kent, P. J.; Faulkner, D. A. A.; Marshall, G. F.

    2016-10-01

    A UK MoD funded programme into autonomous sensors arrays (SAPIENT) has been developing new, highly capable sensor modules together with a scalable modular architecture for control and communication. As part of this system there is a desire to also utilise existing legacy sensors. The paper reports upon the development of a SAPIENT-compliant sensor module using a legacy Close-Circuit Television (CCTV) pan-tilt-zoom (PTZ) camera. The PTZ camera sensor provides three modes of operation. In the first mode, the camera is automatically slewed to acquire imagery of a specified scene area, e.g. to provide "eyes-on" confirmation for a human operator or for forensic purposes. In the second mode, the camera is directed to monitor an area of interest, with zoom level automatically optimized for human detection at the appropriate range. Open source algorithms (using OpenCV) are used to automatically detect pedestrians; their real world positions are estimated and communicated back to the SAPIENT central fusion system. In the third mode of operation a "follow" mode is implemented where the camera maintains the detected person within the camera field-of-view without requiring an end-user to directly control the camera with a joystick.

  1. Mitigation of cross-beam energy transfer: Implication of two-state focal zooming on OMEGA

    NASA Astrophysics Data System (ADS)

    Froula, D. H.; Kessler, T. J.; Igumenshchev, I. V.; Betti, R.; Goncharov, V. N.; Huang, H.; Hu, S. X.; Hill, E.; Kelly, J. H.; Meyerhofer, D. D.; Shvydky, A.; Zuegel, J. D.

    2013-08-01

    Cross-beam energy transfer (CBET) during OMEGA low-adiabat cryogenic experiments reduces the hydrodynamic efficiency by ˜35%, which lowers the calculated one-dimensional (1-D) yield by a factor of 7. CBET can be mitigated by reducing the diameter of the laser beams relative to the target diameter. Reducing the diameter of the laser beams by 30%, after a sufficient conduction zone has been generated (two-state zooming), is predicted to maintain low-mode uniformity while recovering 90% of the kinetic energy lost to CBET. A radially varying phase plate is proposed to implement two-state zooming on OMEGA. A beam propagating through the central half-diameter of the phase plate will produce a large spot, while a beam propagating through the outer annular region of the phase plate will produce a narrower spot. To generate the required two-state near-field laser-beam profile, a picket driver with smoothing by spectral dispersion (SSD) would pass through an apodizer, forming a beam of half the standard diameter. A second main-pulse driver would co-propagate without SSD through its own apodizer, forming a full-diameter annular beam. Hydrodynamic simulations, using the designed laser spots produced by the proposed zooming scheme on OMEGA, show that implementing zooming will increase the implosion velocity by 25% resulting in a 4.5× increase in the 1-D neutron yield. Demonstrating zooming on OMEGA would validate a viable direct-drive CBET mitigation scheme and help establish a pathway to hydrodynamically equivalent direct-drive-ignition implosions by increasing the ablation pressure (1.6×), which will allow for more stable implosions at ignition-relevant velocities.

  2. Neuromodelling based on evolutionary robotics: on the importance of motor control for spatial attention.

    PubMed

    Gigliotta, Onofrio; Bartolomeo, Paolo; Miglino, Orazio

    2015-09-01

    Mainstream approaches to modelling cognitive processes have typically focused on (1) reproducing their neural underpinning, without regard to sensory-motor systems and (2) producing a single, ideal computational model. Evolutionary robotics is an alternative possibility to bridge the gap between neural substrate and behavior by means of a sensory-motor apparatus, and a powerful tool to build a population of individuals rather than a single model. We trained 4 populations of neurorobots, equipped with a pan/tilt/zoom camera, and provided with different types of motor control in order to perform a cancellation task, often used to tap spatial cognition. Neurorobots' eye movements were controlled by (a) position, (b) velocity, (c) simulated muscles and (d) simulated muscles with fixed level of zoom. Neurorobots provided with muscle and velocity control showed better performances than those controlled in position. This is an interesting result since muscle control can be considered a particular type of position control. Finally, neurorobots provided with muscle control and zoom outperformed those without zooming ability.

  3. ZOOM: a generic personal computer-based teaching program for public health and its application in schistosomiasis control.

    PubMed Central

    Martin, G. T.; Yoon, S. S.; Mott, K. E.

    1991-01-01

    Schistosomiasis, a group of parasitic diseases caused by Schistosoma parasites, is associated with water resources development and affects more than 200 million people in 76 countries. Depending on the species of parasite involved, disease of the liver, spleen, gastrointestinal or urinary tract, or kidneys may result. A computer-assisted teaching package has been developed by WHO for use in the training of public health workers involved in schistosomiasis control. The package consists of the software, ZOOM, and a schistosomiasis information file, Dr Schisto, and uses hypermedia technology to link pictures and text. ZOOM runs on the IBM-PC and IBM-compatible computers, is user-friendly, requires a minimal hardware configuration, and can interact with the user in English, French, Spanish or Portuguese. The information files for ZOOM can be created or modified by the instructor using a word processor, and thus can be designed to suit the need of students. No programming knowledge is required to create the stacks. PMID:1786618

  4. Development of a dry actuation conducting polymer actuator for micro-optical zoom lenses

    NASA Astrophysics Data System (ADS)

    Kim, Baek-Chul; Kim, Hyunseok; Nguyen, H. C.; Cho, M. S.; Lee, Y.; Nam, Jae-Do; Choi, Hyouk Ryeol; Koo, J. C.; Jeong, H.-S.

    2008-03-01

    The objective of the present work is to demonstrate the efficiency and feasibility of NBR (Nitrile Butadiene Rubber) based conducting polymer actuator that is fabricated into a micro zoon lens driver. Unlike the traditional conducting polymer that normally operates in a liquid, the proposed actuator successfully provides fairly effective driving performance for the zoom lens system in a dry environment. And this paper is including the experiment results for an efficiency improvement. The result suggested by an experiment was efficient in micro optical zoom lens system. In addition, the developed design method of actuator was given consideration to design the system.

  5. Cardio-PACs: a new opportunity

    NASA Astrophysics Data System (ADS)

    Heupler, Frederick A., Jr.; Thomas, James D.; Blume, Hartwig R.; Cecil, Robert A.; Heisler, Mary

    2000-05-01

    It is now possible to replace film-based image management in the cardiac catheterization laboratory with a Cardiology Picture Archiving and Communication System (Cardio-PACS) based on digital imaging technology. The first step in the conversion process is installation of a digital image acquisition system that is capable of generating high-quality DICOM-compatible images. The next three steps, which are the subject of this presentation, involve image display, distribution, and storage. Clinical requirements and associated cost considerations for these three steps are listed below: Image display: (1) Image quality equal to film, with DICOM format, lossless compression, image processing, desktop PC-based with color monitor, and physician-friendly imaging software; (2) Performance specifications include: acquire 30 frames/sec; replay 15 frames/sec; access to file server 5 seconds, and to archive 5 minutes; (3) Compatibility of image file, transmission, and processing formats; (4) Image manipulation: brightness, contrast, gray scale, zoom, biplane display, and quantification; (5) User-friendly control of image review. Image distribution: (1) Standard IP-based network between cardiac catheterization laboratories, file server, long-term archive, review stations, and remote sites; (2) Non-proprietary formats; (3) Bidirectional distribution. Image storage: (1) CD-ROM vs disk vs tape; (2) Verification of data integrity; (3) User-designated storage capacity for catheterization laboratory, file server, long-term archive. Costs: (1) Image acquisition equipment, file server, long-term archive; (2) Network infrastructure; (3) Review stations and software; (4) Maintenance and administration; (5) Future upgrades and expansion; (6) Personnel.

  6. Zooming in on Science

    ERIC Educational Resources Information Center

    Thorn, Courtney; Rye, James; Walls, Holly

    2017-01-01

    Photography is a creative art that continues to advance through technological innovations. Smart phones have made photography a nearly daily occurance, and people have become quite accustomed to zooming in and taking photos. This article explains how elementary teachers can harness a much "bigger" technology application--GigaPan--to help…

  7. Real-time high-resolution PC-based system for measurement of errors on compact disks

    NASA Astrophysics Data System (ADS)

    Tehranchi, Babak; Howe, Dennis G.

    1994-10-01

    Hardware and software utilities are developed to directly monitor the Eight-to-Fourteen (EFM) demodulated data bytes at the input of a CD player's Cross-Interleaved Reed-Solomon Code (CIRC) block decoder. The hardware is capable of identifying erroneous data with single-byte resolution in the serial data stream read from a Compact Disc by a CDD 461 Philips CD-ROM drive. In addition, the system produces graphical maps that show the physical location of the measured errors on the entire disc, or via a zooming and planning feature, on user selectable local disc regions.

  8. Mechanically assisted liquid lens zoom system for mobile phone cameras

    NASA Astrophysics Data System (ADS)

    Wippermann, F. C.; Schreiber, P.; Bräuer, A.; Berge, B.

    2006-08-01

    Camera systems with small form factor are an integral part of today's mobile phones which recently feature auto focus functionality. Ready to market solutions without moving parts have been developed by using the electrowetting technology. Besides virtually no deterioration, easy control electronics and simple and therefore cost-effective fabrication, this type of liquid lenses enables extremely fast settling times compared to mechanical approaches. As a next evolutionary step mobile phone cameras will be equipped with zoom functionality. We present first order considerations for the optical design of a miniaturized zoom system based on liquid-lenses and compare it to its mechanical counterpart. We propose a design of a zoom lens with a zoom factor of 2.5 considering state-of-the-art commercially available liquid lens products. The lens possesses auto focus capability and is based on liquid lenses and one additional mechanical actuator. The combination of liquid lenses and a single mechanical actuator enables extremely short settling times of about 20ms for the auto focus and a simplified mechanical system design leading to lower production cost and longer life time. The camera system has a mechanical outline of 24mm in length and 8mm in diameter. The lens with f/# 3.5 provides market relevant optical performance and is designed for an image circle of 6.25mm (1/2.8" format sensor).

  9. RM-10A robotic manipulator system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, J.R.; Coughlan, J.B.; Harvey, H.W.

    1988-01-01

    The REMOTE RM-10A is a man-replacement manipulator system that has been developed specifically for use in radioactive and other hazardous environments. It can be teleoperated, with man-in-the-loop, for unstructured tasks or programmed to perform routine tasks automatically much like robots in the automated manufacturing industry. The RM-10A is a servomanipulator utilizing a closed-loop, microprocessor-based control system. The system consists of a slave assembly, master control station, and interconnecting cabling. The slave assembly is the part of the system that enters the hostile environment. It is man-like is size and configuration with two identical arms attached to a torso structure. Eachmore » arm attaches to the torso using two captive screws and two guide pins. The guide pins position and stabilize an arm during removal and reinstallation and also align the two electrical connectors located in the arm support plate and torso. These features allow easy remote replacement of an arm, and commonality of the arms allow interchangeability. The water-resistant slave assembly is equipped with gaskets and O-ring seals in the torso and arm and camera assemblies. In addition, each slave arm's elbow, wrist, and tong are protected by replaceable polyurethane boots. An upper camera assembly, consisting of a color television (TV) camera, 6:1 zoom lens, and a pan/tilt unit, mount to the torso to provide remote viewing capability.« less

  10. Gradient Index Optics at DARPA

    DTIC Science & Technology

    2013-11-01

    four efforts were selected for further development and demonstration: fluidic adaptive zoom lenses, foveated imaging, photon sieves, and nanolayer...2-4 1. Fluidic Adaptive Zoom Lenses... gastropod mollusks. In simple optical systems such as the fish lens, the focal length is a function of the wavelength of light. This distortion is called

  11. Ultrathin zoom lens system based on liquid lenses

    NASA Astrophysics Data System (ADS)

    Li, Lei; Liu, Chao; Wang, Qiong-Hua

    2015-07-01

    In this paper, we propose an ultrathin zoom lens system based on liquid lenses. The proposed system consists of an annular folded lens and three electrowetting liquid lenses. The annular folded lens has several concentric surfaces. The annular folded lens is used to get the main power and correct aberrations. The three liquid lenses are used to change the focal length and correct aberration. An analysis of the proposed system is presented along with the design, fabrication, and testing of a prototype. All the elements in the proposed system are very thin, so the system is an ultrathin zoom lens system, which has potential application as lightweight, thin, high-quality imagers for aerospace, consumer, and military applications.

  12. The use of color infrared photography for wetlands assessment

    NASA Technical Reports Server (NTRS)

    Enslin, W. R.; Sullivan, M. C.

    1974-01-01

    A study was undertaken of Pointe Mouillee Marsh, located on Lake Erie, to assess shoreline erosion and to inventory and evaluate adjacent land as potential replacement for areas lost to erosion, and to provide better data sources for management decisions. The results of the study were: (1) Evaluation of low altitude oblique photography was useful in determining specifications of operational mission requirements; (2) Accurate base map revisions, reflecting shoreline erosion, were made using aerial photography and a Zoom Transfer Scope; (3) An aerial land cover inventory provided data necessary for the selection of adjacent lands suitable for marshland development; (4) A detailed inventory of vegetative communities (mapped from CIR), was made for management decisions; and (5) A carefully selected and well laid-out transect was a key asset to photo interpretation and analysis of vegetation.

  13. V: Musing

    ERIC Educational Resources Information Center

    Rosenfeld, Malke; Kelin, Daniel; Plows, Kate; Conarro, Ryan; Broderick, Debora

    2014-01-01

    When one says "writing about teaching artist practice," what exactly does that mean? In the first two sections (EJ1039315 and EJ1039319), the authors considered different ways to frame a story by either zooming in closely to a specific moment or zooming out to provide more context in an effort to address complex issues. The stories in…

  14. Iberian Spanish "Macho": Vantages and Polysemy in Culturally Defined Meaning

    ERIC Educational Resources Information Center

    Grace, Caroline A.; Glaz, Adam

    2010-01-01

    This study explores some specific aspects of compatibility between cognitive models. Robert E. MacLaury's theory of vantages as arrangements of coordinates and Lakoff's concept of radial categories are mutually reinforcing to an analysis of semantic polysemy. Vantage Theory (VT) includes the notions of "zooming in" and "zooming out", allowing…

  15. Zooming in on Landing Site

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on the image for movie of Zooming in on Landing Site

    This animation zooms in on the area on Mars where NASA's Phoenix Mars Lander will touchdown on May 25, 2008. The image was taken by the High Resolution Imaging Science Experiment (HiRISE) camera on NASA's Mars Reconnaissance Orbiter.

    The first shot shows the spacecraft's landing ellipse in green, the area where Phoenix has a high probability of landing. It then zooms in to show the region's arctic terrain. This polar landscape is relatively free of rocks, with only about 1 to 2 rocks 1.5 meters (4.9 feet) or larger in an area about as big as two football fields.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace & Technologies Corp., Boulder, Colo.

  16. Genoviz Software Development Kit: Java tool kit for building genomics visualization applications.

    PubMed

    Helt, Gregg A; Nicol, John W; Erwin, Ed; Blossom, Eric; Blanchard, Steven G; Chervitz, Stephen A; Harmon, Cyrus; Loraine, Ann E

    2009-08-25

    Visualization software can expose previously undiscovered patterns in genomic data and advance biological science. The Genoviz Software Development Kit (SDK) is an open source, Java-based framework designed for rapid assembly of visualization software applications for genomics. The Genoviz SDK framework provides a mechanism for incorporating adaptive, dynamic zooming into applications, a desirable feature of genome viewers. Visualization capabilities of the Genoviz SDK include automated layout of features along genetic or genomic axes; support for user interactions with graphical elements (Glyphs) in a map; a variety of Glyph sub-classes that promote experimentation with new ways of representing data in graphical formats; and support for adaptive, semantic zooming, whereby objects change their appearance depending on zoom level and zooming rate adapts to the current scale. Freely available demonstration and production quality applications, including the Integrated Genome Browser, illustrate Genoviz SDK capabilities. Separation between graphics components and genomic data models makes it easy for developers to add visualization capability to pre-existing applications or build new applications using third-party data models. Source code, documentation, sample applications, and tutorials are available at http://genoviz.sourceforge.net/.

  17. Fast T1 and T2 mapping methods: the zoomed U-FLARE sequence compared with EPI and snapshot-FLASH for abdominal imaging at 11.7 Tesla.

    PubMed

    Pastor, Géraldine; Jiménez-González, María; Plaza-García, Sandra; Beraza, Marta; Reese, Torsten

    2017-06-01

    A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods. Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence. Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look-Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms. This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.

  18. Numerical Zooming Between a NPSS Engine System Simulation and a One-Dimensional High Compressor Analysis Code

    NASA Technical Reports Server (NTRS)

    Follen, Gregory; auBuchon, M.

    2000-01-01

    Within NASA's High Performance Computing and Communication (HPCC) program, NASA Glenn Research Center is developing an environment for the analysis/design of aircraft engines called the Numerical Propulsion System Simulation (NPSS). NPSS focuses on the integration of multiple disciplines such as aerodynamics, structures, and heat transfer along with the concept of numerical zooming between zero-dimensional to one-, two-, and three-dimensional component engine codes. In addition, the NPSS is refining the computing and communication technologies necessary to capture complex physical processes in a timely and cost-effective manner. The vision for NPSS is to create a "numerical test cell" enabling full engine simulations overnight on cost-effective computing platforms. Of the different technology areas that contribute to the development of the NPSS Environment, the subject of this paper is a discussion on numerical zooming between a NPSS engine simulation and higher fidelity representations of the engine components (fan, compressor, burner, turbines, etc.). What follows is a description of successfully zooming one-dimensional (row-by-row) high-pressure compressor analysis results back to a zero-dimensional NPSS engine simulation and a discussion of the results illustrated using an advanced data visualization tool. This type of high fidelity system-level analysis, made possible by the zooming capability of the NPSS, will greatly improve the capability of the engine system simulation and increase the level of virtual test conducted prior to committing the design to hardware.

  19. Television monitor field shifter and an opto-electronic method for obtaining a stereo image of optimal depth resolution and reduced depth distortion on a single screen

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B. (Inventor)

    1989-01-01

    A method and apparatus is developed for obtaining a stereo image with reduced depth distortion and optimum depth resolution. Static and dynamic depth distortion and depth resolution tradeoff is provided. Cameras obtaining the images for a stereo view are converged at a convergence point behind the object to be presented in the image, and the collection-surface-to-object distance, the camera separation distance, and the focal lengths of zoom lenses for the cameras are all increased. Doubling the distances cuts the static depth distortion in half while maintaining image size and depth resolution. Dynamic depth distortion is minimized by panning a stereo view-collecting camera system about a circle which passes through the convergence point and the camera's first nodal points. Horizontal field shifting of the television fields on a television monitor brings both the monitor and the stereo views within the viewer's limit of binocular fusion.

  20. CPHC/WFO Honolulu Gallery

    Science.gov Websites

    another search. Multiple locations were found. Please select one of the following: Close Location Help Top view Zoom in shot of snow on the Big Island Summits 11/5/2007 (photo by Andrew Beavers (NWS)) Zoom in shot of snow on the Big Island Summits 11/5/2007 (photo by Andrew Beavers (NWS)) Click for larger view

  1. Photographic zoom fisheye lens design for DSLR cameras

    NASA Astrophysics Data System (ADS)

    Yan, Yufeng; Sasian, Jose

    2017-09-01

    Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.

  2. A reflection polarizations zoom metasurfaces

    NASA Astrophysics Data System (ADS)

    Yang, Fulong; Wang, Xiaoyan

    2017-02-01

    Based on generalized Snell's law, we propose a dual-polarity zoom metasurfaces operating electromagnetic wave in the reflection geometry. The metasurfaces is constructed by two identical ultrathin metal-backed dielectric slabs with metallic Jerusalem cross patterns on the other sides to form a triangular region. The normally incident waves are totally reflected, but the reflection phases of both x- and y-polarized waves are controlled independently. According to the classical theory of optical imaging, the reflection electromagnetic wave phases were obtained in the different polarizations and focus. Each subwavelength units size were determined with the reflection coefficient of the basic unit, the polarizations zoom metasurfaces was designed in the way. The full-wave simulations are in good agreement with theoretical analysis in microwave lengths.

  3. Chromatic correction for a VIS-SWIR zoom lens using optical glasses

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Williams, Daniel J. L.; McCarthy, Peter; Visconti, Anthony J.; Bentley, Julie L.; Moore, Duncan T.

    2015-09-01

    With the advancement in sensors, hyperspectral imaging in short wave infrared (SWIR 0.9 μm to 1.7 μm) now has wide applications, including night vision, haze-penetrating imaging, etc. Most conventional optical glasses can be material candidates for designing in the SWIR as they transmit up to 2.2 μm. However, since SWIR is in the middle of the glasses' major absorption wavebands in UV and IR, the flint glasses in SWIR are less dispersive than in the visible spectrum. As a result, the glass map in the SWIR is highly compressed, with crowns and flints all clustering together. Thus correcting for chromatic aberration is more challenging in the SWIR, since the Abbé number ratio of the same glass combination is reduced. Conventionally, fluorides, such as CaF2 and BaF2, are widely used in designing SWIR system due to their unique dispersion properties, even though they are notorious for poor manufacturability or even high toxicity. For lens elements in a zoom system, the ray bundle samples different sections of the each lens aperture as the lens zooms. This creates extra uncertainty in correcting chromatic aberrations. This paper focuses on using only commercially available optical glasses to color-correct a 3X dual-band zoom lens system in the VIS-SWIR. The design tools and techniques are detailed in terms of material selections to minimize the chromatic aberrations in such a large spectrum band and all zoom positions. Examples are discussed for designs with different aperture stop locations, which considerably affect the material choices.

  4. Stereoscopic 3D reconstruction using motorized zoom lenses within an embedded system

    NASA Astrophysics Data System (ADS)

    Liu, Pengcheng; Willis, Andrew; Sui, Yunfeng

    2009-02-01

    This paper describes a novel embedded system capable of estimating 3D positions of surfaces viewed by a stereoscopic rig consisting of a pair of calibrated cameras. Novel theoretical and technical aspects of the system are tied to two aspects of the design that deviate from typical stereoscopic reconstruction systems: (1) incorporation of an 10x zoom lens (Rainbow- H10x8.5) and (2) implementation of the system on an embedded system. The system components include a DSP running μClinux, an embedded version of the Linux operating system, and an FPGA. The DSP orchestrates data flow within the system and performs complex computational tasks and the FPGA provides an interface to the system devices which consist of a CMOS camera pair and a pair of servo motors which rotate (pan) each camera. Calibration of the camera pair is accomplished using a collection of stereo images that view a common chess board calibration pattern for a set of pre-defined zoom positions. Calibration settings for an arbitrary zoom setting are estimated by interpolation of the camera parameters. A low-computational cost method for dense stereo matching is used to compute depth disparities for the stereo image pairs. Surface reconstruction is accomplished by classical triangulation of the matched points from the depth disparities. This article includes our methods and results for the following problems: (1) automatic computation of the focus and exposure settings for the lens and camera sensor, (2) calibration of the system for various zoom settings and (3) stereo reconstruction results for several free form objects.

  5. Integrin Alpha-v and HER2 in Breast Cancer Brain Metastasis

    DTIC Science & Technology

    2015-10-01

    ZOOM live cell imaging machine (ESSEN Bioscience; Figure 2). c. Interactions of αv integrin and HER2 in breast cancer brain metastases. We found...HCC1954 breast cancer cells. C) Real time live cell imaging of MM2BH cells treated with cilengitide (0, .3, 1, 3, and 10 µg/mL) using IncuCyte ZOOM

  6. Videos Bridging Asia and Africa: Overcoming Cultural and Institutional Barriers in Technology-Mediated Rural Learning

    ERIC Educational Resources Information Center

    Van Mele, Paul; Wanvoeke, Jonas; Akakpo, Cyriaque; Dacko, Rosaline Maiga; Ceesay, Mustapha; Beavogui, Louis; Soumah, Malick; Anyang, Robert

    2010-01-01

    Will African farmers watch and learn from videos featuring farmers in Bangladesh? Learning videos on rice seed management were made with rural women in Bangladesh. By using a new approach, called zooming-in, zooming-out, the videos were of regional relevance and locally appropriate. When the Africa Rice Center (AfricaRice) introduced them to…

  7. Low-Rate Information Transmission (LRIT) - NOAA Satellite Information

    Science.gov Websites

    bulletins and notices and an updated area where further explanations can be found. GOES-East Full Disk Image Viewed Using LRIT GOES-EAST full disk image viewed using LRIT. Zoomed In Portion of the LRIT Full Disk Image. A zoomed in portion of the LRIT full disk image. Contact Information: LRIT / EMWIN: Paul Seymour

  8. New long-zoom lens for 4K super 35mm digital cameras

    NASA Astrophysics Data System (ADS)

    Thorpe, Laurence J.; Usui, Fumiaki; Kamata, Ryuhei

    2015-05-01

    The world of television production is beginning to adopt 4K Super 35 mm (S35) image capture for a widening range of program genres that seek both the unique imaging properties of that large image format and the protection of their program assets in a world anticipating future 4K services. Documentary and natural history production in particular are transitioning to this form of production. The nature of their shooting demands long zoom lenses. In their traditional world of 2/3-inch digital HDTV cameras they have a broad choice in portable lenses - with zoom ranges as high as 40:1. In the world of Super 35mm the longest zoom lens is limited to 12:1 offering a telephoto of 400mm. Canon was requested to consider a significantly longer focal range lens while severely curtailing its size and weight. Extensive computer simulation explored countless combinations of optical and optomechanical systems in a quest to ensure that all operational requests and full 4K performance could be met. The final lens design is anticipated to have applications beyond entertainment production, including a variety of security systems.

  9. Monitoring small-crack growth by the replication method

    NASA Technical Reports Server (NTRS)

    Swain, Mary H.

    1992-01-01

    The suitability of the acetate replication method for monitoring the growth of small cracks is discussed. Applications of this technique are shown for cracks growing at the notch root in semicircular-edge-notch specimens of a variety of aluminum alloys and one steel. The calculated crack growth rate versus Delta K relationship for small cracks was compared to that for large cracks obtained from middle-crack-tension specimens. The primary advantage of this techinque is that it provides an opportunity, at the completion of the test, to go backward in time towards the crack initiation event and 'zoom in' on areas of interest on the specimen surface with a resolution of about 0.1 micron. The primary disadvantage is the inability to automate the process. Also, for some materials, the replication process may alter the crack-tip chemistry or plastic zone, thereby affecting crack growth rates.

  10. Crater monitoring through social media observations

    NASA Astrophysics Data System (ADS)

    Gialampoukidis, I.; Vrochidis, S.; Kompatsiaris, I.

    2017-09-01

    We have collected more than one lunar image per two days from social media observations. Each one of the collected images has been clustered into two main groups of lunar images and an additional cluster is provided (noise) with pictures that have not been assigned to any cluster. The proposed lunar image clustering process provides two classes of lunar pictures, at different zoom levels; the first showing a clear view of craters grouped into one cluster and the second demonstrating a complete view of the Moon at various phases that are correlated with the crawling date. The clustering stage is unsupervised, so new topics can be detected on-the-fly. We have provided additional sources of planetary images using crowdsourcing information, which is associated with metadata such as time, text, location, links to other users and other related posts. This content has crater information that can be fused with other planetary data to enhance crater monitoring.

  11. Zooming In on Plant Hormone Analysis: Tissue- and Cell-Specific Approaches.

    PubMed

    Novák, Ondřej; Napier, Richard; Ljung, Karin

    2017-04-28

    Plant hormones are a group of naturally occurring, low-abundance organic compounds that influence physiological processes in plants. Our knowledge of the distribution profiles of phytohormones in plant organs, tissues, and cells is still incomplete, but advances in mass spectrometry have enabled significant progress in tissue- and cell-type-specific analyses of phytohormones over the last decade. Mass spectrometry is able to simultaneously identify and quantify hormones and their related substances. Biosensors, on the other hand, offer continuous monitoring; can visualize local distributions and real-time quantification; and, in the case of genetically encoded biosensors, are noninvasive. Thus, biosensors offer additional, complementary technologies for determining temporal and spatial changes in phytohormone concentrations. In this review, we focus on recent advances in mass spectrometry-based quantification, describe monitoring systems based on biosensors, and discuss validations of the various methods before looking ahead at future developments for both approaches.

  12. Annular ring zoom system using two positive axicons

    NASA Astrophysics Data System (ADS)

    Dickey, Fred M.; Conner, Jacob D.

    2011-10-01

    The production of an annular ring of light with a variable diameter has applications in laser material processing and machining, particle manipulation, and corneal surgery. This can readily be accomplished using a positive and negative axicon pair. However, negative axicons are very expensive and difficult to obtain with small diameters. In this paper, we present a design of an annular ring zoom system using two positive axicons. One axicon is placed a distance before a primary lens that is greater than some prescribed minimum, and the second axicon is placed after the primary lens. The position of the second axicon determines the ring diameter. The ring diameter can be zoomed from some maximum design size to a zero diameter ring (spot). Experimental results from a developmental system will be presented.

  13. Indirect (source-free) integration method. I. Wave-forms from geodesic generic orbits of EMRIs

    NASA Astrophysics Data System (ADS)

    Ritter, Patxi; Aoudia, Sofiane; Spallicci, Alessandro D. A. M.; Cordier, Stéphane

    2016-12-01

    The Regge-Wheeler-Zerilli (RWZ) wave-equation describes Schwarzschild-Droste black hole perturbations. The source term contains a Dirac distribution and its derivative. We have previously designed a method of integration in time domain. It consists of a finite difference scheme where analytic expressions, dealing with the wave-function discontinuity through the jump conditions, replace the direct integration of the source and the potential. Herein, we successfully apply the same method to the geodesic generic orbits of EMRI (Extreme Mass Ratio Inspiral) sources, at second order. An EMRI is a Compact Star (CS) captured by a Super-Massive Black Hole (SMBH). These are considered the best probes for testing gravitation in strong regime. The gravitational wave-forms, the radiated energy and angular momentum at infinity are computed and extensively compared with other methods, for different orbits (circular, elliptic, parabolic, including zoom-whirl).

  14. Object Based Numerical Zooming Between the NPSS Version 1 and a 1-Dimensional Meanline High Pressure Compressor Design Analysis Code

    NASA Technical Reports Server (NTRS)

    Follen, G.; Naiman, C.; auBuchon, M.

    2000-01-01

    Within NASA's High Performance Computing and Communication (HPCC) program, NASA Glenn Research Center is developing an environment for the analysis/design of propulsion systems for aircraft and space vehicles called the Numerical Propulsion System Simulation (NPSS). The NPSS focuses on the integration of multiple disciplines such as aerodynamics, structures, and heat transfer, along with the concept of numerical zooming between 0- Dimensional to 1-, 2-, and 3-dimensional component engine codes. The vision for NPSS is to create a "numerical test cell" enabling full engine simulations overnight on cost-effective computing platforms. Current "state-of-the-art" engine simulations are 0-dimensional in that there is there is no axial, radial or circumferential resolution within a given component (e.g. a compressor or turbine has no internal station designations). In these 0-dimensional cycle simulations the individual component performance characteristics typically come from a table look-up (map) with adjustments for off-design effects such as variable geometry, Reynolds effects, and clearances. Zooming one or more of the engine components to a higher order, physics-based analysis means a higher order code is executed and the results from this analysis are used to adjust the 0-dimensional component performance characteristics within the system simulation. By drawing on the results from more predictive, physics based higher order analysis codes, "cycle" simulations are refined to closely model and predict the complex physical processes inherent to engines. As part of the overall development of the NPSS, NASA and industry began the process of defining and implementing an object class structure that enables Numerical Zooming between the NPSS Version I (0-dimension) and higher order 1-, 2- and 3-dimensional analysis codes. The NPSS Version I preserves the historical cycle engineering practices but also extends these classical practices into the area of numerical zooming for use within a companies' design system. What follows here is a description of successfully zooming I-dimensional (row-by-row) high pressure compressor results back to a NPSS engine 0-dimension simulation and a discussion of the results illustrated using an advanced data visualization tool. This type of high fidelity system-level analysis, made possible by the zooming capability of the NPSS, will greatly improve the fidelity of the engine system simulation and enable the engine system to be "pre-validated" prior to commitment to engine hardware.

  15. Cartographic analyses of geographic information available on Google Earth Images

    NASA Astrophysics Data System (ADS)

    Oliveira, J. C.; Ramos, J. R.; Epiphanio, J. C.

    2011-12-01

    The propose was to evaluate planimetric accuracy of satellite images available on database of Google Earth. These images are referents to the vicinities of the Federal Univertisity of Viçosa, Minas Gerais - Brazil. The methodology developed evaluated the geographical information of three groups of images which were in accordance to the level of detail presented in the screen images (zoom). These groups of images were labeled to Zoom 1000 (a single image for the entire study area), Zoom 100 (formed by a mosaic of 73 images) and Zoom 100 with geometric correction (this mosaic is like before, however, it was applied a geometric correction through control points). In each group of image was measured the Cartographic Accuracy based on statistical analyses and brazilian's law parameters about planimetric mapping. For this evaluation were identified 22 points in each group of image, where the coordinates of each point were compared to the coordinates of the field obtained by GPS (Global Positioning System). The Table 1 show results related to accuracy (based on a threshold equal to 0.5 mm * mapping scale) and tendency (abscissa and ordinate) between the coordinates of the image and the coordinates of field. Table 1 The geometric correction applied to the Group Zoom 100 reduced the trends identified earlier, and the statistical tests pointed a usefulness of the data for a mapping at a scale of 1/5000 with error minor than 0.5 mm * scale. The analyses proved the quality of cartographic data provided by Google, as well as the possibility of reduce the divergences of positioning present on the data. It can be concluded that it is possible to obtain geographic information database available on Google Earth, however, the level of detail (zoom) used at the time of viewing and capturing information on the screen influences the quality cartographic of the mapping. Although cartographic and thematic potential present in the database, it is important to note that both the software as data distributed by Google Earth has policies for use and distribution.
    Table 1 - PLANIMETRIC ANALYSIS

  16. On the relationship between human search strategies, conspicuity, and search performance

    NASA Astrophysics Data System (ADS)

    Hogervorst, Maarten A.; Bijl, Piet; Toet, Alexander

    2005-05-01

    We determined the relationship between search performance with a limited field of view (FOV) and several scanning- and scene parameters in human observer experiments. The observers (38 trained army scouts) searched through a large search sector for a target (a camouflaged person) on a heath. From trial to trial the target appeared at a different location. With a joystick the observers scanned through a panoramic image (displayed on a PC-monitor) while the scan path was registered. Four conditions were run differing in sensor type (visual or thermal infrared) and window size (large or small). In conditions with a small window size the zoom option could be used. Detection performance was highly dependent on zoom factor and deteriorated when scan speed increased beyond a threshold value. Moreover, the distribution of scan speeds scales with the threshold speed. This indicates that the observers are aware of their limitations and choose a (near) optimal search strategy. We found no correlation between the fraction of detected targets and overall search time for the individual observers, indicating that both are independent measures of individual search performance. Search performance (fraction detected, total search time, time in view for detection) was found to be strongly related to target conspicuity. Moreover, we found the same relationship between search performance and conspicuity for visual and thermal targets. This indicates that search performance can be predicted directly by conspicuity regardless of the sensor type.

  17. Fast inner-volume imaging of the lumbar spine with a spatially focused excitation using a 3D-TSE sequence.

    PubMed

    Riffel, Philipp; Michaely, Henrik J; Morelli, John N; Paul, Dominik; Kannengiesser, Stephan; Schoenberg, Stefan O; Haneder, Stefan

    2015-04-01

    The purpose of this study was to evaluate the feasibility and technical quality of a zoomed three-dimensional (3D) turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip-angle evolutions (SPACE) sequence of the lumbar spine. In this prospective feasibility study, nine volunteers underwent a 3-T magnetic resonance examination of the lumbar spine including 1) a conventional 3D T2-weighted (T2w) SPACE sequence with generalized autocalibrating partially parallel acquisition technique acceleration factor 2 and 2) a zoomed 3D T2w SPACE sequence with a reduced field of view (reduction factor 2). Images were evaluated with regard to image sharpness, signal homogeneity, and the presence of artifacts by two experienced radiologists. For quantitative analysis, signal-to-noise ratio (SNR) values were calculated. Image sharpness of anatomic structures was statistically significantly greater with zoomed SPACE (P < .0001), whereas the signal homogeneity was statistically significantly greater with conventional SPACE (cSPACE; P = .0003). There were no statistically significant differences in extent of artifacts. Acquisition times were 8:20 minutes for cSPACE and 6:30 minutes for zoomed SPACE. Readers 1 and 2 selected zSPACE as the preferred sequence in five of nine cases. In two of nine cases, both sequences were rated as equally preferred by both the readers. SNR values were statistically significantly greater with cSPACE. In comparison to a cSPACE sequences, zoomed SPACE imaging of the lumbar spine provides sharper images in conjunction with a 25% reduction in acquisition time. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  18. Design of a novel Hyper-spectral riflescope system

    NASA Astrophysics Data System (ADS)

    Huang, YunHan; Fu, YueGang

    2016-10-01

    Hyper-spectral imaging involves many research areas, such as optics, spectroscopy, mechanical, microelectronics, and computers, etc. Hyper-spectral imaging system has an irreplaceable role in the detection field. At present, due to the improvement of camouflage technology, characteristic of target in battlefield becomes more complex and the targets became more and more difficult to be detected, According to this phenomenon the author designed a novel hyper-spectral riflescope optical system. In general, the riflescope optical system is composed of two parts front object lens and zoom relay system. Firstly, dispersion characteristics of the typical optical glasses varies during band 400nm 1 000nm, the author derived apochromatic theory that suitable to the front system and relay system without using special glass, and make a example to testify its correctness. In general, the zoom mode of relay system lens is different from the objective lens system, so we should take consideration of them separately. Secondly, based on the above theory, the articles designed a hyper-spectral riflescope system, which has a continuous zoom curve, zoom ratio is 4 times and the F number of the system is 4.8;Full field of view varies during 1.8° 7.2°.Structure of the system is relatively compact, and has not used special glass, eventually the article give the schematic of system MTF and zoom curves of relay movable parts. the curve is smooth and can be applied to practical engineering. The author adopt ZEMAX design software to analyses the results .Design result shows that, in the visible and near-infrared wavelengths, the MTF of imaging system at 60lp / mm during all bands are greater than 0.3, which prove the correctness of the design theory and good performance of system.

  19. Bridging the scales in a eulerian air quality model to assess megacity export of pollution

    NASA Astrophysics Data System (ADS)

    Siour, G.; Colette, A.; Menut, L.; Bessagnet, B.; Coll, I.; Meleux, F.

    2013-08-01

    In Chemistry Transport Models (CTMs), spatial scale interactions are often represented through off-line coupling between large and small scale models. However, those nested configurations cannot give account of the impact of the local scale on its surroundings. This issue can be critical in areas exposed to air mass recirculation (sea breeze cells) or around regions with sharp pollutant emission gradients (large cities). Such phenomena can still be captured by the mean of adaptive gridding, two-way nesting or using model nudging, but these approaches remain relatively costly. We present here the development and the results of a simple alternative multi-scale approach making use of a horizontal stretched grid, in the Eulerian CTM CHIMERE. This method, called "stretching" or "zooming", consists in the introduction of local zooms in a single chemistry-transport simulation. It allows bridging online the spatial scales from the city (∼1 km resolution) to the continental area (∼50 km resolution). The CHIMERE model was run over a continental European domain, zoomed over the BeNeLux (Belgium, Netherlands and Luxembourg) area. We demonstrate that, compared with one-way nesting, the zooming method allows the expression of a significant feedback of the refined domain towards the large scale: around the city cluster of BeNeLuX, NO2 and O3 scores are improved. NO2 variability around BeNeLux is also better accounted for, and the net primary pollutant flux transported back towards BeNeLux is reduced. Although the results could not be validated for ozone over BeNeLux, we show that the zooming approach provides a simple and immediate way to better represent scale interactions within a CTM, and constitutes a useful tool for apprehending the hot topic of megacities within their continental environment.

  20. Trend of digital camera and interchangeable zoom lenses with high ratio based on patent application over the past 10 years

    NASA Astrophysics Data System (ADS)

    Sensui, Takayuki

    2012-10-01

    Although digitalization has tripled consumer-class camera market scale, extreme reductions in prices of fixed-lens cameras has reduced profitability. As a result, a number of manufacturers have entered the market of the System DSC i.e. digital still camera with interchangeable lens, where large profit margins are possible, and many high ratio zoom lenses with image stabilization functions have been released. Quiet actuators are another indispensable component. Design with which there is little degradation in performance due to all types of errors is preferred for good balance in terms of size, lens performance, and the rate of quality to sub-standard products. Decentering, such as that caused by tilting, sensitivity of moving groups is especially important. In addition, image stabilization mechanisms actively shift lens groups. Development of high ratio zoom lenses with vibration reduction mechanism is confronted by the challenge of reduced performance due to decentering, making control over decentering sensitivity between lens groups everything. While there are a number of ways to align lenses (axial alignment), shock resistance and ability to stand up to environmental conditions must also be considered. Naturally, it is very difficult, if not impossible, to make lenses smaller and achieve a low decentering sensitivity at the same time. 4-group zoom construction is beneficial in making lenses smaller, but decentering sensitivity is greater. 5-group zoom configuration makes smaller lenses more difficult, but it enables lower decentering sensitivities. At Nikon, the most advantageous construction is selected for each lens based on specifications. The AF-S DX NIKKOR 18-200mm f/3.5-5.6G ED VR II and AF-S NIKKOR 28-300mm f/3.5-5.6G ED VR are excellent examples of this.

  1. Design of laser afocal zoom expander system

    NASA Astrophysics Data System (ADS)

    Jiang, Lian; Zeng, Chun-Mei; Hu, Tian-Tian

    2018-01-01

    Laser afocal zoom expander system due to the beam diameter variable, can be used in the light sheet illumination microscope to observe the samples of different sizes. Based on the principle of afocal zoom system, the laser collimation and beam expander system with a total length of less than 110mm, 6 pieces of spherical lens and a beam expander ratio of 10 is designed by using Zemax software. The system is focused on laser with a wavelength of 532nm, divergence angle of less than 4mrad and incident diameter of 4mm. With the combination of 6 spherical lens, the beam divergence angle is 0.4mrad at the maximum magnification ratio, and the RMS values at different rates are less than λ/4. This design is simple in structure and easy to process and adjust. It has certain practical value.

  2. Zooming in on the cause of the perceptual load effect in the go/no-go paradigm.

    PubMed

    Chen, Zhe; Cave, Kyle R

    2016-08-01

    Perceptual load theory (Lavie, 2005) claims that attentional capacity that is not used for the current task is allocated to irrelevant distractors. It predicts that if the attentional demands of the current task are high, distractor interference will be low. One particularly powerful demonstration of perceptual load effects on distractor processing relies on a go/no-go cue that is interpreted by either simple feature detection or feature conjunction (Lavie, 1995). However, a possible alternative interpretation of these effects is that the differential degree of distractor processing is caused by how broadly attention is allocated (attentional zoom) rather than to perceptual load. In 4 experiments, we show that when stimuli are arranged to equalize the extent of spatial attention across conditions, distractor interference varies little whether cues are defined by a simple feature or a conjunction, and that the typical perceptual load effect emerges only when attentional zoom can covary with perceptual load. These results suggest that attentional zoom can account for the differential degree of distractor processing traditionally attributed to perceptual load in the go/no-go paradigm. They also provide new insight into how different factors interact to control distractor interference. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  3. Implementation of focal zooming on the Nike KrF laser

    NASA Astrophysics Data System (ADS)

    Kehne, D. M.; Karasik, M.; Aglitsky, Y.; Smyth, Z.; Terrell, S.; Weaver, J. L.; Chan, Y.; Lehmberg, R. H.; Obenschain, S. P.

    2013-01-01

    In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser (λ = 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 μm thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

  4. Implementation of focal zooming on the Nike KrF laser.

    PubMed

    Kehne, D M; Karasik, M; Aglitsky, Y; Smyth, Z; Terrell, S; Weaver, J L; Chan, Y; Lehmberg, R H; Obenschain, S P

    2013-01-01

    In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser (λ = 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 μm thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

  5. Micromechanics of composite laminate compression failure

    NASA Technical Reports Server (NTRS)

    Guynn, E. Gail; Bradley, Walter L.

    1986-01-01

    The Dugdale analysis for metals loaded in tension was adapted to model the failure of notched composite laminates loaded in compression. Compression testing details, MTS alignment verification, and equipment needs were resolved. Thus far, only 2 ductile material systems, HST7 and F155, were selected for study. A Wild M8 Zoom Stereomicroscope and necessary attachments for video taping and 35 mm pictures were purchased. Currently, this compression test system is fully operational. A specimen is loaded in compression, and load vs shear-crippling zone size is monitored and recorded. Data from initial compression tests indicate that the Dugdale model does not accurately predict the load vs damage zone size relationship of notched composite specimens loaded in compression.

  6. MOLA: Seasonal Snow Variations on Mars: Slow Flyover of the Martian North Pole

    NASA Technical Reports Server (NTRS)

    2001-01-01

    MOLA: Seasonal Snow Variations on Mars: Slow Flyover of the Martian North Pole: False Color. This is a visualization of the topography near the Martian north pole as measured with the MOLA instrument. This particular animation shows a slow zoom to the surface of the pole, a flyover of the polar cap and a slow zoom out. The surface color is based on the elevation of the topography.

  7. Fast digital zooming system using directionally adaptive image interpolation and restoration.

    PubMed

    Kang, Wonseok; Jeon, Jaehwan; Yu, Soohwan; Paik, Joonki

    2014-01-01

    This paper presents a fast digital zooming system for mobile consumer cameras using directionally adaptive image interpolation and restoration methods. The proposed interpolation algorithm performs edge refinement along the initially estimated edge orientation using directionally steerable filters. Either the directionally weighted linear or adaptive cubic-spline interpolation filter is then selectively used according to the refined edge orientation for removing jagged artifacts in the slanted edge region. A novel image restoration algorithm is also presented for removing blurring artifacts caused by the linear or cubic-spline interpolation using the directionally adaptive truncated constrained least squares (TCLS) filter. Both proposed steerable filter-based interpolation and the TCLS-based restoration filters have a finite impulse response (FIR) structure for real time processing in an image signal processing (ISP) chain. Experimental results show that the proposed digital zooming system provides high-quality magnified images with FIR filter-based fast computational structure.

  8. Electrowetting-actuated zoom lens with spherical-interface liquid lenses.

    PubMed

    Peng, Runling; Chen, Jiabi; Zhuang, Songlin

    2008-11-01

    The interface shape of two immiscible liquids in a conical chamber is discussed. The analytical solution of the differential equation describing the interface shape shows that the interface shape is completely spherical when the density difference of two liquids is zero. On the basis of the spherical-interface shape and an energy-minimization method, explicit calculations and detailed analyses of an extended Young-type equation for the conical double-liquid lens are given. Finally, a novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two conical double-liquid variable-focus lenses. The structure and principle of the lens system are introduced in this paper. Taking finite objects as example, detailed calculations and simulation examples are presented to predict how two liquid lenses are related to meet the basic requirements of zoom lenses.

  9. Graded zooming

    DOEpatents

    Coffland, Douglas R.

    2006-04-25

    A system for increasing the resolution in the far field resolution of video or still frame images, while maintaining full coverage in the near field. The system includes a camera connected to a computer. The computer applies a specific zooming scale factor to each of line of pixels and continuously increases the scale factor of the line of pixels from the bottom to the top to capture the scene in the near field, yet maintain resolution in the scene in the far field.

  10. The analysis of the wavefront aberration caused by the gravity of the tunable-focus liquid-filled membrane lens

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Liu, Pengfei; Wei, Xiaona; Zhuang, Songlin; Yang, Bo

    2010-11-01

    Liquid lens is a novel optical device which can implement active zooming. With liquid lens, zoom camera can be designed with more miniature size and simpler structure than before. It is thought that the micro zoom system with liquid lens has a very wide potential applications in many fields, in which the volume and weight of the system are critically limited, such as endoscope, mobile, PDA and so on. There are mainly three types of tunable-focus liquid lens: liquid crystal lens, electrowetting effect based liquid lens and liquid-filled membrane lens. Comparing with the other two kinds of liquid lens, the liquid-filled membrane lens has the advantages of simple structure, flexible aperture and high zooming efficiency. But its membrane surface will have an initial shape deformation caused by the gravity when the aperture of the lens is at large size, which will lead to the wave front aberration and the imaging quality impairing. In this paper, the initial deformation of the lens caused by the gravity was simulated based on the theory of Elastic Mechanics, which was calculated by the Finite Element Analysis method. The relationship between the diameter of the lens and the wave front aberration caused by the gravity was studied. And the Optical path difference produced by different liquid density was also analyzed.

  11. Integration and binding in rehabilitative sensory substitution: Increasing resolution using a new Zooming-in approach

    PubMed Central

    Buchs, Galit; Maidenbaum, Shachar; Levy-Tzedek, Shelly; Amedi, Amir

    2015-01-01

    Purpose: To visually perceive our surroundings we constantly move our eyes and focus on particular details, and then integrate them into a combined whole. Current visual rehabilitation methods, both invasive, like bionic-eyes and non-invasive, like Sensory Substitution Devices (SSDs), down-sample visual stimuli into low-resolution images. Zooming-in to sub-parts of the scene could potentially improve detail perception. Can congenitally blind individuals integrate a ‘visual’ scene when offered this information via different sensory modalities, such as audition? Can they integrate visual information –perceived in parts - into larger percepts despite never having had any visual experience? Methods: We explored these questions using a zooming-in functionality embedded in the EyeMusic visual-to-auditory SSD. Eight blind participants were tasked with identifying cartoon faces by integrating their individual components recognized via the EyeMusic’s zooming mechanism. Results: After specialized training of just 6–10 hours, blind participants successfully and actively integrated facial features into cartooned identities in 79±18% of the trials in a highly significant manner, (chance level 10% ; rank-sum P <  1.55E-04). Conclusions: These findings show that even users who lacked any previous visual experience whatsoever can indeed integrate this visual information with increased resolution. This potentially has important practical visual rehabilitation implications for both invasive and non-invasive methods. PMID:26518671

  12. Microscopic Image of Martian Surface Material on a Silicone Substrate

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for larger version of Figure 1

    This image taken by the Optical Microscope on NASA's Phoenix Mars Lander shows soil sprinkled from the lander's Robot Arm scoop onto a silicone substrate. The substrate was then rotated in front of the microscope. This is the first sample collected and delivered for instrumental analysis onboard a planetary lander since NASA's Viking Mars missions of the 1970s. It is also the highest resolution image yet seen of Martian soil.

    The image is dominated by fine particles close to the resolution of the microscope. These particles have formed clumps, which may be a smaller scale version of what has been observed by Phoenix during digging of the surface material.

    The microscope took this image during Phoenix's Sol 17 (June 11), or the 17th Martian day after landing. The scale bar is 1 millimeter (0.04 inch).

    Zooming in on the Martian Soil

    In figure 1, three zoomed-in portions are shown with an image of Martian soil particles taken by the Optical Microscope on NASA's Phoenix Mars Lander.

    The left zoom box shows a composite particle. The top of the particle has a green tinge, possibly indicating olivine. The bottom of the particle has been reimaged at a different focus position in black and white (middle zoom box), showing that this is a clump of finer particles.

    The right zoom box shows a rounded, glassy particle, similar to those which have also been seen in an earlier sample of airfall dust collected on a surface exposed during landing.

    The shadows at the bottom of image are of the beams of the Atomic Force Microscope.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  13. Graphics processing unit (GPU) real-time infrared scene generation

    NASA Astrophysics Data System (ADS)

    Christie, Chad L.; Gouthas, Efthimios (Themie); Williams, Owen M.

    2007-04-01

    VIRSuite, the GPU-based suite of software tools developed at DSTO for real-time infrared scene generation, is described. The tools include the painting of scene objects with radiometrically-associated colours, translucent object generation, polar plot validation and versatile scene generation. Special features include radiometric scaling within the GPU and the presence of zoom anti-aliasing at the core of VIRSuite. Extension of the zoom anti-aliasing construct to cover target embedding and the treatment of translucent objects is described.

  14. Aviation Wide-Angle Visual System (AWAVS). Trainer Design Report. Subsystem Design Report

    DTIC Science & Technology

    1977-05-01

    205 60 Frequency-Gain Plot for FLOLS Meatball Servo 209 61 FLOLS Zoom Servo, Block Diagram 210 62 FLOLS Zoom Iris Servo, Block Diagram and...Servo Input Torques 196 24 FLOLS Servo Components 197 25 FLOLS Meatball Servo Performance 203 26 Inherent Zeros and Poles for FLOLS Meatball Servo...of their relative powers must equal the ratio of 500 ft to the simu- lated range. The FLOLS are on whenever the pilot is within the meatball field

  15. A comparison of locally adaptive multigrid methods: LDC, FAC and FIC

    NASA Technical Reports Server (NTRS)

    Khadra, Khodor; Angot, Philippe; Caltagirone, Jean-Paul

    1993-01-01

    This study is devoted to a comparative analysis of three 'Adaptive ZOOM' (ZOom Overlapping Multi-level) methods based on similar concepts of hierarchical multigrid local refinement: LDC (Local Defect Correction), FAC (Fast Adaptive Composite), and FIC (Flux Interface Correction)--which we proposed recently. These methods are tested on two examples of a bidimensional elliptic problem. We compare, for V-cycle procedures, the asymptotic evolution of the global error evaluated by discrete norms, the corresponding local errors, and the convergence rates of these algorithms.

  16. Real-time near IR (1310 nm) imaging of CO2 laser ablation of enamel.

    PubMed

    Darling, Cynthia L; Fried, Daniel

    2008-02-18

    The high-transparency of dental enamel in the near-IR (NIR) can be exploited for real-time imaging of ablation crater formation during drilling with lasers. NIR images were acquired with an InGaAs focal plane array and a NIR zoom microscope during drilling incisions in human enamel samples with a lambda=9.3-microm CO(2) laser operating at repetition rates of 50-300-Hz with and without a water spray. Crack formation, dehydration and thermal changes were observed during ablation. These initial images demonstrate the potential of NIR imaging to monitor laser-ablation events in real-time to provide information about the mechanism of ablation and to evaluate the potential for peripheral thermal and mechanical damage.

  17. Machine vision guided sensor positioning system for leaf temperature assessment

    NASA Technical Reports Server (NTRS)

    Kim, Y.; Ling, P. P.; Janes, H. W. (Principal Investigator)

    2001-01-01

    A sensor positioning system was developed for monitoring plants' well-being using a non-contact sensor. Image processing algorithms were developed to identify a target region on a plant leaf. A novel algorithm to recover view depth was developed by using a camera equipped with a computer-controlled zoom lens. The methodology has improved depth recovery resolution over a conventional monocular imaging technique. An algorithm was also developed to find a maximum enclosed circle on a leaf surface so the conical field-of-view of an infrared temperature sensor could be filled by the target without peripheral noise. The center of the enclosed circle and the estimated depth were used to define the sensor 3-D location for accurate plant temperature measurement.

  18. Project Zoom IN, Citizen Perspectives on Climate and Water Resources

    NASA Astrophysics Data System (ADS)

    Glaser, J. P.

    2012-12-01

    Perspective on climate and water resources can come from the top, scientists sharing invaluable data and findings about how climate dynamics function or quantifications of systems in flux. However, citizens are endowed with an equally as powerful tool for insight: ground zero experience. Project Zoom In is a nascent project undertaken by Global Media Forge to empower youth, educators and scientists with tools to reach the media with locale-specific imagery and perspective of climate dynamics and evidence of anecdotal resource management of liquid gold: fresh water. Zoom In is taking root in Colorado but is designed for national/international scaling. This effort has three limbs: (1) student, scientist and educator workshops teaching invaluable video production skills (2) engaging Colorado school systems to stimulate submission of clips to full video productions to our database, and (3) embedding the findings on a taxonomic GIS interface on-line. The website will be invaluable in classrooms and link network media to individuals with firsthand viewpoints on change.; Climate and Water Resources

  19. Juicebox.js Provides a Cloud-Based Visualization System for Hi-C Data.

    PubMed

    Robinson, James T; Turner, Douglass; Durand, Neva C; Thorvaldsdóttir, Helga; Mesirov, Jill P; Aiden, Erez Lieberman

    2018-02-28

    Contact mapping experiments such as Hi-C explore how genomes fold in 3D. Here, we introduce Juicebox.js, a cloud-based web application for exploring the resulting datasets. Like the original Juicebox application, Juicebox.js allows users to zoom in and out of such datasets using an interface similar to Google Earth. Juicebox.js also has many features designed to facilitate data reproducibility and sharing. Furthermore, Juicebox.js encodes the exact state of the browser in a shareable URL. Creating a public browser for a new Hi-C dataset does not require coding and can be accomplished in under a minute. The web app also makes it possible to create interactive figures online that can complement or replace ordinary journal figures. When combined with Juicer, this makes the entire process of data analysis transparent, insofar as every step from raw reads to published figure is publicly available as open source code. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Using Power Spectrum Analysis to Evaluate 18O-Water Labeling Data Acquired from Low Resolution Mass Spectrometers

    PubMed Central

    Sadygov, Rovshan G.; Zhao, Yingxin; Haidacher, Sigmund J.; Starkey, Jonathan M.; Tilton, Ronald G.; Denner, Larry

    2010-01-01

    We describe a method for ratio estimations in 18O-water labeling experiments acquired from low resolution isotopically resolved data. The method is implemented in a software package specifically designed for use in experiments making use of zoom-scan mode data acquisition. Zoom-scan mode data allows commonly used ion trap mass spectrometers to attain isotopic resolution, which make them amenable to use in labeling schemes such as 18O-water labeling, but algorithms and software developed for high resolution instruments may not be appropriate for the lower resolution data acquired in zoom-scan mode. The use of power spectrum analysis is proposed as a general approach which may be uniquely suited to these data types. The software implementation uses power spectrum to remove high-frequency noise, and band-filter contributions from co-eluting species of differing charge states. From the elemental composition of a peptide sequence we generate theoretical isotope envelopes of heavy-light peptide pairs in five different ratios; these theoretical envelopes are correlated with the filtered experimental zoom scans. To automate peptide quantification in high-throughput experiments, we have implemented our approach in a computer program, MassXplorer. We demonstrate the application of MassXplorer to two model mixtures of known proteins, and to a complex mixture of mouse kidney cortical extract. Comparison with another algorithm for ratio estimations demonstrates the increased precision and automation of MassXplorer. PMID:20568695

  1. Optical design of an athermalised dual field of view step zoom optical system in MWIR

    NASA Astrophysics Data System (ADS)

    Kucukcelebi, Doruk

    2017-08-01

    In this paper, the optical design of an athermalised dual field of view step zoom optical system in MWIR (3.7μm - 4.8μm) is described. The dual field of view infrared optical system is designed based on the principle of passive athermalization method not only to achieve athermal optical system but also to keep the high image quality within the working temperature between -40°C and +60°C. The infrared optical system used in this study had a 320 pixel x 256 pixel resolution, 20μm pixel pitch size cooled MWIR focal plane array detector. In this study, the step zoom mechanism, which has the axial motion due to consisting of a lens group, is considered to simplify mechanical structure. The optical design was based on moving a single lens along the optical axis for changing the optical system's field of view not only to reduce the number of moving parts but also to athermalize for the optical system. The optical design began with an optimization process using paraxial optics when first-order optics parameters are determined. During the optimization process, in order to reduce aberrations, such as coma, astigmatism, spherical and chromatic aberrations, aspherical surfaces were used. As a result, athermalised dual field of view step zoom optical design is proposed and the performance of the design using proposed method was verified by providing the focus shifts, spot diagrams and MTF analyzes' plots.

  2. Testing the generality of the zoom-lens model: Evidence for visual-pathway specific effects of attended-region size on perception.

    PubMed

    Goodhew, Stephanie C; Lawrence, Rebecca K; Edwards, Mark

    2017-05-01

    There are volumes of information available to process in visual scenes. Visual spatial attention is a critically important selection mechanism that prevents these volumes from overwhelming our visual system's limited-capacity processing resources. We were interested in understanding the effect of the size of the attended area on visual perception. The prevailing model of attended-region size across cognition, perception, and neuroscience is the zoom-lens model. This model stipulates that the magnitude of perceptual processing enhancement is inversely related to the size of the attended region, such that a narrow attended-region facilitates greater perceptual enhancement than a wider region. Yet visual processing is subserved by two major visual pathways (magnocellular and parvocellular) that operate with a degree of independence in early visual processing and encode contrasting visual information. Historically, testing of the zoom-lens has used measures of spatial acuity ideally suited to parvocellular processing. This, therefore, raises questions about the generality of the zoom-lens model to different aspects of visual perception. We found that while a narrow attended-region facilitated spatial acuity and the perception of high spatial frequency targets, it had no impact on either temporal acuity or the perception of low spatial frequency targets. This pattern also held up when targets were not presented centrally. This supports the notion that visual attended-region size has dissociable effects on magnocellular versus parvocellular mediated visual processing.

  3. Modeling the Impact of Baryons on Subhalo Populations with Machine Learning

    NASA Astrophysics Data System (ADS)

    Nadler, Ethan O.; Mao, Yao-Yuan; Wechsler, Risa H.; Garrison-Kimmel, Shea; Wetzel, Andrew

    2018-06-01

    We identify subhalos in dark matter–only (DMO) zoom-in simulations that are likely to be disrupted due to baryonic effects by using a random forest classifier trained on two hydrodynamic simulations of Milky Way (MW)–mass host halos from the Latte suite of the Feedback in Realistic Environments (FIRE) project. We train our classifier using five properties of each disrupted and surviving subhalo: pericentric distance and scale factor at first pericentric passage after accretion and scale factor, virial mass, and maximum circular velocity at accretion. Our five-property classifier identifies disrupted subhalos in the FIRE simulations with an 85% out-of-bag classification score. We predict surviving subhalo populations in DMO simulations of the FIRE host halos, finding excellent agreement with the hydrodynamic results; in particular, our classifier outperforms DMO zoom-in simulations that include the gravitational potential of the central galactic disk in each hydrodynamic simulation, indicating that it captures both the dynamical effects of a central disk and additional baryonic physics. We also predict surviving subhalo populations for a suite of DMO zoom-in simulations of MW-mass host halos, finding that baryons impact each system consistently and that the predicted amount of subhalo disruption is larger than the host-to-host scatter among the subhalo populations. Although the small size and specific baryonic physics prescription of our training set limits the generality of our results, our work suggests that machine-learning classification algorithms trained on hydrodynamic zoom-in simulations can efficiently predict realistic subhalo populations.

  4. CFRP variable curvature mirror used for realizing non-moving-element optical zoom imaging

    NASA Astrophysics Data System (ADS)

    Zhao, Hui; Fan, Xuewu; Pang, Zhihai; Ren, Guorui; Wang, Wei; Xie, Yongjie; Ma, Zhen; Du, Yunfei; Su, Yu; Wei, Jingxuan

    2014-12-01

    In recent years, how to eliminate moving elements while realizing optical zoom imaging has been paid much attention. Compared with the conventional optical zooming techniques, removing moving elements would bring in many benefits such as reduction in weight, volume and power cost and so on. The key to implement non-moving-element optical zooming lies in the design of variable curvature mirror (VCM). In order to obtain big enough optical magnification, the VCM should be capable of generating a large variation of saggitus. Hence, the mirror material should not be brittle, in other words the corresponding ultimate strength should be high enough to ensure that mirror surface would not be broken during large curvature variation. Besides that, the material should have a not too big Young's modulus because in this case less force is required to generate a deformation. Among all available materials, for instance SiC, Zerodur and et.al, CFRP (carbon fiber reinforced polymer) satisfies all these requirements and many related research have proven this. In this paper, a CFRP VCM is designed, fabricated and tested. With a diameter of 100mm, a thickness of 2mm and an initial curvature radius of 1740mm, this component could change its curvature radius from 1705mm to 1760mm, which correspond to a saggitus variation of nearly 23μm. The work reported further proves the suitability of CFRP in constructing variable curvature mirror which could generate a large variation of saggitus.

  5. View southeast of computer controlled energy monitoring system. System replaced ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of computer controlled energy monitoring system. System replaced strip chart recorders and other instruments under the direct observation of the load dispatcher. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    EDENBURN,MICHAEL W.; TROST,LAWRENCE C.

    This paper compares the cost and effectiveness of several potential options that may be used to monitor silo-based ballistic missiles. Silo door monitoring can be used to verify that warheads removed to deactivate or download silo-based ballistic missiles have not been replaced. A precedent for monitoring warhead replacement using reentry vehicle on site inspections (RV-OSIs) and using satellites has been established by START-I and START-II. However, other monitoring options have the potential to be less expensive and more effective. Three options are the most promising if high verification confidence is desired: random monitoring using door sensors; random monitoring using mannedmore » or unmanned aircraft; and continuous remote monitoring using unattended door sensors.« less

  7. Benefit of the UltraZoom beamforming technology in noise in cochlear implant users.

    PubMed

    Mosnier, Isabelle; Mathias, Nathalie; Flament, Jonathan; Amar, Dorith; Liagre-Callies, Amelie; Borel, Stephanie; Ambert-Dahan, Emmanuèle; Sterkers, Olivier; Bernardeschi, Daniele

    2017-09-01

    The objectives of the study were to demonstrate the audiological and subjective benefits of the adaptive UltraZoom beamforming technology available in the Naída CI Q70 sound processor, in cochlear-implanted adults upgraded from a previous generation sound processor. Thirty-four adults aged between 21 and 89 years (mean 53 ± 19) were prospectively included. Nine subjects were unilaterally implanted, 11 bilaterally and 14 were bimodal users. The mean duration of cochlear implant use was 7 years (range 5-15 years). Subjects were tested in quiet with monosyllabic words and in noise with the adaptive French Matrix test in the best-aided conditions. The test setup contained a signal source in front of the subject and three noise sources at +/-90° and 180°. The noise was presented at a fixed level of 65 dB SPL and the level of speech signal was varied to obtain the speech reception threshold (SRT). During the upgrade visit, subjects were tested with the Harmony and with the Naída CI sound processors in omnidirectional microphone configuration. After a take-home phase of 2 months, tests were repeated with the Naída CI processor with and without UltraZoom. Subjective assessment of the sound quality in daily environments was recorded using the APHAB questionnaire. No difference in performance was observed in quiet between the two processors. The Matrix test in noise was possible in the 21 subjects with the better performance. No difference was observed between the two processors for performance in noise when using the omnidirectional microphone. At the follow-up session, the median SRT with the Naída CI processor with UltraZoom was -4 dB compared to -0.45 dB without UltraZoom. The use of UltraZoom improved the median SRT by 3.6 dB (p < 0.0001, Wilcoxon paired test). When looking at the APHAB outcome, improvement was observed for speech understanding in noisy environments (p < 0.01) and in aversive situations (p < 0.05) in the group of 21 subjects who were able to perform the Matrix test in noise and for speech understanding in noise (p < 0.05) in the group of 13 subjects with the poorest performance, who were not able to perform the Matrix test in noise. The use of UltraZoom beamforming technology, available on the new sound processor Naída CI, improves speech performance in difficult and realistic noisy conditions when the cochlear implant user needs to focus on the person speaking at the front. Using the APHAB questionnaire, a subjective benefit for listening in background noise was also observed in subjects with good performance as well as in those with poor performance. This study highlighted the importance of upgrading CI recipients to new technology and to include assessment in noise and subjective feedback evaluation as part of the process.

  8. Engineering web maps with gradual content zoom based on streaming vector data

    NASA Astrophysics Data System (ADS)

    Huang, Lina; Meijers, Martijn; Šuba, Radan; van Oosterom, Peter

    2016-04-01

    Vario-scale data structures have been designed to support gradual content zoom and the progressive transfer of vector data, for use with arbitrary map scales. The focus to date has been on the server side, especially on how to convert geographic data into the proposed vario-scale structures by means of automated generalisation. This paper contributes to the ongoing vario-scale research by focusing on the client side and communication, particularly on how this works in a web-services setting. It is claimed that these functionalities are urgently needed, as many web-based applications, both desktop and mobile, require gradual content zoom, progressive transfer and a high performance level. The web-client prototypes developed in this paper make it possible to assess the behaviour of vario-scale data and to determine how users will actually see the interactions. Several different options of web-services communication architectures are possible in a vario-scale setting. These options are analysed and tested with various web-client prototypes, with respect to functionality, ease of implementation and performance (amount of transmitted data and response times). We show that the vario-scale data structure can fit in with current web-based architectures and efforts to standardise map distribution on the internet. However, to maximise the benefits of vario-scale data, a client needs to be aware of this structure. When a client needs a map to be refined (by means of a gradual content zoom operation), only the 'missing' data will be requested. This data will be sent incrementally to the client from a server. In this way, the amount of data transferred at one time is reduced, shortening the transmission time. In addition to these conceptual architecture aspects, there are many implementation and tooling design decisions at play. These will also be elaborated on in this paper. Based on the experiments conducted, we conclude that the vario-scale approach indeed supports gradual content zoom and the progressive web transfer of vector data. This is a big step forward in making vector data at arbitrary map scales available to larger user groups.

  9. Self-monitoring as a viable fading option in check-in/check-out.

    PubMed

    Miller, Leila M; Dufrene, Brad A; Joe Olmi, D; Tingstrom, Daniel; Filce, Hollie

    2015-04-01

    This study systematically replaced the teacher completed Daily Behavior Report Card (DBRC) and feedback component of check-in/check-out (CICO) with self-monitoring for four elementary students referred for Tier 2 behavioral supports within School-Wide Positive Behavior Interventions and Supports (SWPBIS). An ABAB withdrawal design was used to test the effectiveness of CICO. Then, following the second B phase, teacher completion of the DBRC and corresponding feedback to students was replaced with self-monitoring. For all four participants, CICO was associated with increases in academic engagement and reductions in disruptive behavior. Moreover, students' behavioral gains were maintained when teacher completion of the DBRC was replaced with self-monitoring. Results are discussed in terms of CICO research and practice. Copyright © 2014 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  10. Modeling the Impact of Baryons on Subhalo Populations with Machine Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadler, Ethan O.; Mao, Yao -Yuan; Wechsler, Risa H.

    Here, we identify subhalos in dark matter–only (DMO) zoom-in simulations that are likely to be disrupted due to baryonic effects by using a random forest classifier trained on two hydrodynamic simulations of Milky Way (MW)–mass host halos from the Latte suite of the Feedback in Realistic Environments (FIRE) project. We train our classifier using five properties of each disrupted and surviving subhalo: pericentric distance and scale factor at first pericentric passage after accretion and scale factor, virial mass, and maximum circular velocity at accretion. Our five-property classifier identifies disrupted subhalos in the FIRE simulations with an 85% out-of-bag classification score.more » We predict surviving subhalo populations in DMO simulations of the FIRE host halos, finding excellent agreement with the hydrodynamic results; in particular, our classifier outperforms DMO zoom-in simulations that include the gravitational potential of the central galactic disk in each hydrodynamic simulation, indicating that it captures both the dynamical effects of a central disk and additional baryonic physics. We also predict surviving subhalo populations for a suite of DMO zoom-in simulations of MW-mass host halos, finding that baryons impact each system consistently and that the predicted amount of subhalo disruption is larger than the host-to-host scatter among the subhalo populations. Although the small size and specific baryonic physics prescription of our training set limits the generality of our results, our work suggests that machine-learning classification algorithms trained on hydrodynamic zoom-in simulations can efficiently predict realistic subhalo populations.« less

  11. Modeling the Impact of Baryons on Subhalo Populations with Machine Learning

    DOE PAGES

    Nadler, Ethan O.; Mao, Yao -Yuan; Wechsler, Risa H.; ...

    2018-06-01

    Here, we identify subhalos in dark matter–only (DMO) zoom-in simulations that are likely to be disrupted due to baryonic effects by using a random forest classifier trained on two hydrodynamic simulations of Milky Way (MW)–mass host halos from the Latte suite of the Feedback in Realistic Environments (FIRE) project. We train our classifier using five properties of each disrupted and surviving subhalo: pericentric distance and scale factor at first pericentric passage after accretion and scale factor, virial mass, and maximum circular velocity at accretion. Our five-property classifier identifies disrupted subhalos in the FIRE simulations with an 85% out-of-bag classification score.more » We predict surviving subhalo populations in DMO simulations of the FIRE host halos, finding excellent agreement with the hydrodynamic results; in particular, our classifier outperforms DMO zoom-in simulations that include the gravitational potential of the central galactic disk in each hydrodynamic simulation, indicating that it captures both the dynamical effects of a central disk and additional baryonic physics. We also predict surviving subhalo populations for a suite of DMO zoom-in simulations of MW-mass host halos, finding that baryons impact each system consistently and that the predicted amount of subhalo disruption is larger than the host-to-host scatter among the subhalo populations. Although the small size and specific baryonic physics prescription of our training set limits the generality of our results, our work suggests that machine-learning classification algorithms trained on hydrodynamic zoom-in simulations can efficiently predict realistic subhalo populations.« less

  12. An electronic pan/tilt/zoom camera system

    NASA Technical Reports Server (NTRS)

    Zimmermann, Steve; Martin, H. Lee

    1991-01-01

    A camera system for omnidirectional image viewing applications that provides pan, tilt, zoom, and rotational orientation within a hemispherical field of view (FOV) using no moving parts was developed. The imaging device is based on the effect that from a fisheye lens, which produces a circular image of an entire hemispherical FOV, can be mathematically corrected using high speed electronic circuitry. An incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical FOV without the need for any mechanical mechanisms. A programmable transformation processor provides flexible control over viewing situations. Multiple images, each with different image magnifications and pan tilt rotation parameters, can be obtained from a single camera. The image transformation device can provide corrected images at frame rates compatible with RS-170 standard video equipment.

  13. Numerical Propulsion System Simulation: A Common Tool for Aerospace Propulsion Being Developed

    NASA Technical Reports Server (NTRS)

    Follen, Gregory J.; Naiman, Cynthia G.

    2001-01-01

    The NASA Glenn Research Center is developing an advanced multidisciplinary analysis environment for aerospace propulsion systems called the Numerical Propulsion System Simulation (NPSS). This simulation is initially being used to support aeropropulsion in the analysis and design of aircraft engines. NPSS provides increased flexibility for the user, which reduces the total development time and cost. It is currently being extended to support the Aviation Safety Program and Advanced Space Transportation. NPSS focuses on the integration of multiple disciplines such as aerodynamics, structure, and heat transfer with numerical zooming on component codes. Zooming is the coupling of analyses at various levels of detail. NPSS development includes using the Common Object Request Broker Architecture (CORBA) in the NPSS Developer's Kit to facilitate collaborative engineering. The NPSS Developer's Kit will provide the tools to develop custom components and to use the CORBA capability for zooming to higher fidelity codes, coupling to multidiscipline codes, transmitting secure data, and distributing simulations across different platforms. These powerful capabilities will extend NPSS from a zero-dimensional simulation tool to a multifidelity, multidiscipline system-level simulation tool for the full life cycle of an engine.

  14. The Making of NASA's Global Selfie: 100+ Countries, Thousands of Photos

    NASA Image and Video Library

    2014-05-22

    The 3.2 gigapixel Global Selfie mosaic, hosted by GigaPan, was made with 36,422 individual images that were posted to social media sites on or around Earth Day, April 22, 2014. Zoom in and find yours here: 1.usa.gov/SnR7ki Credit: NASA The 3.2 gigapixel Global Selfie mosaic, hosted by GigaPan, was made with 36,422 individual images that were posted to social media sites on or around Earth Day, April 22, 2014. Zoom in and find yours here: 1.usa.gov/SnR7ki

  15. Variable focus photographic lens without mechanical movements

    NASA Astrophysics Data System (ADS)

    Chen, Jiabi; Peng, Runling; Zhuang, Songlin

    2007-09-01

    A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. And detailed calculations and simulation examples are presented to predict how two liquid lenses are related to meet the basic requirements of zoom lenses.

  16. Integrated Circuit Wear out Prediction and Recycling Detection using Radio Frequency Distinct Native Attribute Features

    DTIC Science & Technology

    2016-12-22

    105 A.1 Main Loop ... loop monitoring for preventative maintenance rather than early replacement based on statistical projections or replacement-after- failure schemes. IC...estimates, RF-DNA may provide a means to track an IC’s physical degradation during actual use. Monitoring an IC’s degradation in a closed loop fashion

  17. Comparing Baltimore and Phoenix

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The 'zoom lens' aboard NASA's Terra spacecraft acquired these views of two U.S. cities: Baltimore, Maryland (left), and Phoenix, Arizona (right). Acquired by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), red in these false-colored images indicates vegetation. The turquoise pixels show paved areas while darker greens and browns show bare earth and rock surfaces. The 'true' constructed nature of these cities is not easy to see. Ecologists now accept human beings and our activities as a significant factor in studying the Earth's ecology. ASTER data are being used to better understand urban ecology, in particular how humans build their cities and affect the surrounding environment. At the recent American Geophysical Union (AGU) meeting in Boston, Will Stefanov of Arizona State University presented the first set of ASTER images of the urban 'skeletons' of the amount of built structures in twelve cities around the world. He also discussed the Urban Environmental Monitoring project, in which scientists are examining 100 urban centers to look for common features (or lack of them) in global city structure as well as to monitor their changes over time.

  18. Tooth Whitening And Temperature Rise With Two Bleaching Activation Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abu-ElMagd, D. M.; El-Sayad, I. I.; Abd El-Gawad, L. M.

    2009-09-27

    To measure the tooth whitening and the surface and Intrapulpal temperature increase in vitro on freshly extracted upper human central incisors after chemical, Zoom AP light and diode laser activated bleaching. Thirty caries-free upper human incisors were selected. Teeth were divided into three equal groups according to the methods of activation of the bleaching agent (n = 10). A whitening gel containing hydrogen peroxide was applied to the buccal surface of all teeth. Group I was bleached using chemically activated hydrogen peroxide gel, for three applications of 15 min each. Group II was bleached with high intensity advanced power Zoommore » activation light (Zoom AP), for three applications of 15 min each. Group III was bleached with diode laser activation technique, where the teeth were irradiated with 2 Watt diode laser for three applications of 30 sec each. The whitening degree was assessed using an image analysis system, while temperature rise was recorded using a thermocouple on the external tooth surface and Intrapulpal. The degree of whitening increased significantly in all groups. However, the percentage of whitening was not statistically significantly different between the three groups. In addition, group II showed statistically significant higher mean rise in both surface and pulp temperatures than group I and group III. Chemical bleaching produces the same whitening effect as Zoom AP light and laser, with no surface or pulpal temperature rise. Laser application is faster and produces less surface and pulp temperature increase than Zoom AP light. Diode laser used to activate bleaching gels is not considered dangerous to the vitality of dental pulp using power settings of 2 W.« less

  19. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury

    PubMed Central

    Jiang, JingLe; Marathe, Amar R.; Keene, Jennifer C.; Taylor, Dawn M.

    2016-01-01

    Background Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. New Method We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Results Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. Comparison with Existing Methods For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Conclusions Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. PMID:27979758

  20. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

    PubMed

    Jiang, JingLe; Marathe, Amar R; Keene, Jennifer C; Taylor, Dawn M

    2017-02-01

    Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. Published by Elsevier B.V.

  1. High prevalence of iatrogenic hyperthyroidism in elderly patients with atrial fibrillation in an anticoagulation clinic.

    PubMed

    Krishnan, Sandeep Kumar; Dohrmann, Mary L; Brietzke, Stephen A; Fleming, David A; Flaker, Greg C

    2011-01-01

    In elderly patients with established atrial fibrillation (AF) who are receiving thyroid replacement, regular testing for thyroid function is often not performed, placing the patient at risk for iatrogenic hyperthyroidism. Of 215 patients followed in an anticoagulation clinic, 41 were receiving thyroid replacement and 15 of these were found to have hyperthyroidism. Eight had documented AF coincident with abnormal thyroid function. In addition, only 22 patients on thyroid replacement had an annual TSH. In conclusion, iatrogenic hyperthyroidism may frequently be missed in AF patients because of inadequate monitoring of serum TSH. Thyroid replacement is common in elderly patients with AF followed in an anticoagulation clinic. Laboratory evidence of hyperthyroidism occurred in 37%, usually in patients with higher doses of thyroid replacement, and often associated with AF. The frequency of iatrogenic hyperthyroidism may be underestimated in patients with AF since many patients who receive thyroid replacement therapy are not monitored regularly with serum TSH.

  2. Concurrent image-based visual servoing with adaptive zooming for non-cooperative rendezvous maneuvers

    NASA Astrophysics Data System (ADS)

    Pomares, Jorge; Felicetti, Leonard; Pérez, Javier; Emami, M. Reza

    2018-02-01

    An image-based servo controller for the guidance of a spacecraft during non-cooperative rendezvous is presented in this paper. The controller directly utilizes the visual features from image frames of a target spacecraft for computing both attitude and orbital maneuvers concurrently. The utilization of adaptive optics, such as zooming cameras, is also addressed through developing an invariant-image servo controller. The controller allows for performing rendezvous maneuvers independently from the adjustments of the camera focal length, improving the performance and versatility of maneuvers. The stability of the proposed control scheme is proven analytically in the invariant space, and its viability is explored through numerical simulations.

  3. Tunable Metasurface and Flat Optical Zoom Lens on a Stretchable Substrate.

    PubMed

    Ee, Ho-Seok; Agarwal, Ritesh

    2016-04-13

    A mechanically reconfigurable metasurface that can continuously tune the wavefront is demonstrated in the visible frequency range by changing the lattice constant of a complex Au nanorod array fabricated on a stretchable polydimethylsiloxane substrate. It is shown that the anomalous refraction angle of visible light at 632.8 nm interacting with the tunable metasurface can be adjusted from 11.4° to 14.9° by stretching the substrate by ∼30%. An ultrathin flat 1.7× zoom lens whose focal length can continuously be changed from 150 to 250 μm is realized, which also demonstrates the potential of utilizing metasurfaces for reconfigurable flat optics.

  4. Using GBrowse 2.0 to visualize and share next-generation sequence data

    PubMed Central

    2013-01-01

    GBrowse is a mature web-based genome browser that is suitable for deployment on both public and private web sites. It supports most of genome browser features, including qualitative and quantitative (wiggle) tracks, track uploading, track sharing, interactive track configuration, semantic zooming and limited smooth track panning. As of version 2.0, GBrowse supports next-generation sequencing (NGS) data by providing for the direct display of SAM and BAM sequence alignment files. SAM/BAM tracks provide semantic zooming and support both local and remote data sources. This article provides step-by-step instructions for configuring GBrowse to display NGS data. PMID:23376193

  5. Variable curvature mirror having variable thickness: design and fabrication

    NASA Astrophysics Data System (ADS)

    Zhao, Hui; Xie, Xiaopeng; Xu, Liang; Ding, Jiaoteng; Shen, Le; Gong, Jie

    2017-10-01

    Variable curvature mirror (VCM) can change its curvature radius dynamically and is usually used to correct the defocus and spherical aberration caused by thermal lens effect to improve the output beam quality of high power solid-state laser. Recently, the probable application of VCM in realizing non-moving element optical zoom imaging in visible band has been paid much attention. The basic requirement for VCM lies in that it should provide a large enough saggitus variation and still maintains a high enough surface figure at the same time. Therefore in this manuscript, by combing the pressurization based actuation with a variable thickness mirror design, the purpose of obtaining large saggitus variation and maintaining quite good surface figure accuracy at the same time could be achieved. A prototype zoom mirror with diameter of 120mm and central thickness of 8mm is designed, fabricated and tested. Experimental results demonstrate that the zoom mirror having an initial surface figure accuracy superior to 1/80λ could provide bigger than 36um saggitus variation and after finishing the curvature variation its surface figure accuracy could still be superior to 1/40λ with the spherical aberration removed, which proves that the effectiveness of the theoretical design.

  6. Lossless Data Embedding—New Paradigm in Digital Watermarking

    NASA Astrophysics Data System (ADS)

    Fridrich, Jessica; Goljan, Miroslav; Du, Rui

    2002-12-01

    One common drawback of virtually all current data embedding methods is the fact that the original image is inevitably distorted due to data embedding itself. This distortion typically cannot be removed completely due to quantization, bit-replacement, or truncation at the grayscales 0 and 255. Although the distortion is often quite small and perceptual models are used to minimize its visibility, the distortion may not be acceptable for medical imagery (for legal reasons) or for military images inspected under nonstandard viewing conditions (after enhancement or extreme zoom). In this paper, we introduce a new paradigm for data embedding in images (lossless data embedding) that has the property that the distortion due to embedding can be completely removed from the watermarked image after the embedded data has been extracted. We present lossless embedding methods for the uncompressed formats (BMP, TIFF) and for the JPEG format. We also show how the concept of lossless data embedding can be used as a powerful tool to achieve a variety of nontrivial tasks, including lossless authentication using fragile watermarks, steganalysis of LSB embedding, and distortion-free robust watermarking.

  7. Holographic near-eye display system based on double-convergence light Gerchberg-Saxton algorithm.

    PubMed

    Sun, Peng; Chang, Shengqian; Liu, Siqi; Tao, Xiao; Wang, Chang; Zheng, Zhenrong

    2018-04-16

    In this paper, a method is proposed to implement noises reduced three-dimensional (3D) holographic near-eye display by phase-only computer-generated hologram (CGH). The CGH is calculated from a double-convergence light Gerchberg-Saxton (GS) algorithm, in which the phases of two virtual convergence lights are introduced into GS algorithm simultaneously. The first phase of convergence light is a replacement of random phase as the iterative initial value and the second phase of convergence light will modulate the phase distribution calculated by GS algorithm. Both simulations and experiments are carried out to verify the feasibility of the proposed method. The results indicate that this method can effectively reduce the noises in the reconstruction. Field of view (FOV) of the reconstructed image reaches 40 degrees and experimental light path in the 4-f system is shortened. As for 3D experiments, the results demonstrate that the proposed algorithm can present 3D images with 180cm zooming range and continuous depth cues. This method may provide a promising solution in future 3D augmented reality (AR) realization.

  8. Treatment of Addison's disease during pregnancy.

    PubMed

    Oliveira, Diana; Lages, Adriana; Paiva, Sandra; Carrilho, Francisco

    2018-01-01

    Addison's disease, or primary adrenocortical insufficiency, is a long-term, potentially severe, rare endocrine disorder. In pregnancy, it is even rarer. We report the case of a 30-year-old pregnant patient with Addison's disease, referred to Obstetrics-Endocrinology specialty consult at 14 weeks gestation. She had been to the emergency department of her local hospital various times during the first trimester presenting with a clinical scenario suggestive of glucocorticoid under-replacement (nausea, persistent vomiting and hypotension), but this was interpreted as normal pregnancy symptoms. Hydrocortisone dose was adjusted, and the patient maintained regular follow-up. No complications were reported for the remainder of gestation and delivery. Pregnant patients with Addison's disease should be monitored during gestation and in the peripartum period by multidisciplinary teams. Adjustments in glucocorticoid and mineralocorticoid replacement therapy are often necessary, and monitoring should be based mainly on clinical findings, which becomes increasingly difficult during pregnancy. Patient education and specialized monitoring are key to avoiding complications from under- or over-replacement therapy in this period. An increase in glucocorticoid replacement dose is expected to be necessary during pregnancy in a woman with Addison's disease.Patient education regarding steroid cover and symptoms of acute adrenal crisis are fundamental.Monitoring in this period is challenging and remains mainly clinical.The increase in hydrocortisone dose often obviates the need to increase fludrocortisone dose.

  9. High phenobarbital clearance during continuous renal replacement therapy: a case report and pharmacokinetic analysis.

    PubMed

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-08-01

    Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring.A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure.Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus.The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed.Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring.

  10. High Phenobarbital Clearance During Continuous Renal Replacement Therapy

    PubMed Central

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-01-01

    Abstract Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring. A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure. Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus. The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed. Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring. PMID:25101986

  11. Self and External Monitoring of Reading Comprehension

    ERIC Educational Resources Information Center

    Shiu, Ling-po; Chen, Qishan

    2013-01-01

    The present study compared the effectiveness of 2 approaches to remedy the inaccuracy of self-monitoring of reading comprehension. The first approach attempts to enhance self-monitoring by strengthening the cues utilized in monitoring. The second approach replaces self-monitoring with external regulation based on objective evaluative information.…

  12. Varo-achro-phobia: the fear of broad spectrum zoom optics

    NASA Astrophysics Data System (ADS)

    Vogel, Steven; Pollica, Naomi

    2015-05-01

    Today's battlefield is evolving at light speed. Our war fighters are being tasked with highly complex missions requiring the very best technology our industry can offer. The demand for advanced ISR platforms is challenging designers and engineers in the optics industry to push the envelope and develop wider band solutions to support multiple and broadband sensor platforms. Recently, significant attention has been directed towards the development of optical systems that enable simultaneous operation in the visible and shortwave infrared spectral wavebands. This paper will present a review of the evolution of StingRay Optics' GhostSight™ continuous zoom optics that offer broad chromatic imaging capabilities from the visible through the shortwave infrared spectrum.

  13. Coherent x-ray zoom condenser lens for diffractive and scanning microscopy.

    PubMed

    Kimura, Takashi; Matsuyama, Satoshi; Yamauchi, Kazuto; Nishino, Yoshinori

    2013-04-22

    We propose a coherent x-ray zoom condenser lens composed of two-stage deformable Kirkpatrick-Baez mirrors. The lens delivers coherent x-rays with a controllable beam size, from one micrometer to a few tens of nanometers, at a fixed focal position. The lens is suitable for diffractive and scanning microscopy. We also propose non-scanning coherent diffraction microscopy for extended objects by using an apodized focused beam produced by the lens with a spatial filter. The proposed apodized-illumination method will be useful in highly efficient imaging with ultimate storage ring sources, and will also open the way to single-shot coherent diffraction microscopy of extended objects with x-ray free-electron lasers.

  14. Animated Optical Microscope Zoom in from Phoenix Launch to Martian Surface

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for animation

    This animated camera view zooms in from NASA's Phoenix Mars Lander launch site all the way to Phoenix's Microscopy and Electrochemistry and C Eonductivity Analyzer (MECA) aboard the spacecraft on the Martian surface. The final frame shows the soil sample delivered to MECA as viewed through the Optical Microscope (OM) on Sol 17 (June 11, 2008), or the 17th Martian day.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Mechatronic design of a fully integrated camera for mini-invasive surgery.

    PubMed

    Zazzarini, C C; Patete, P; Baroni, G; Cerveri, P

    2013-06-01

    This paper describes the design features of an innovative fully integrated camera candidate for mini-invasive abdominal surgery with single port or transluminal access. The apparatus includes a CMOS imaging sensor, a light-emitting diode (LED)-based unit for scene illumination, a photodiode for luminance detection, an optical system designed according to the mechanical compensation paradigm, an actuation unit for enabling autofocus and optical zoom, and a control logics based on microcontroller. The bulk of the apparatus is characterized by a tubular shape with a diameter of 10 mm and a length of 35 mm. The optical system, composed of four lens groups, of which two are mobile, has a total length of 13.46 mm and an effective focal length ranging from 1.61 to 4.44 mm with a zoom factor of 2.75×, with a corresponding angular field of view ranging from 16° to 40°. The mechatronics unit, devoted to move the zoom and the focus lens groups, is implemented adopting miniature piezoelectric motors. The control logics implements a closed-loop mechanism, between the LEDs and photodiode, to attain automatic control light. Bottlenecks of the design and some potential issues of the realization are discussed. A potential clinical scenario is introduced.

  16. Launch Condition Deviations of Reusable Launch Vehicle Simulations in Exo-Atmospheric Zoom Climbs

    NASA Technical Reports Server (NTRS)

    Urschel, Peter H.; Cox, Timothy H.

    2003-01-01

    The Defense Advanced Research Projects Agency has proposed a two-stage system to deliver a small payload to orbit. The proposal calls for an airplane to perform an exo-atmospheric zoom climb maneuver, from which a second-stage rocket is launched carrying the payload into orbit. The NASA Dryden Flight Research Center has conducted an in-house generic simulation study to determine how accurately a human-piloted airplane can deliver a second-stage rocket to a desired exo-atmospheric launch condition. A high-performance, fighter-type, fixed-base, real-time, pilot-in-the-loop airplane simulation has been modified to perform exo-atmospheric zoom climb maneuvers. Four research pilots tracked a reference trajectory in the presence of winds, initial offsets, and degraded engine thrust to a second-stage launch condition. These launch conditions have been compared to the reference launch condition to characterize the expected deviation. At each launch condition, a speed change was applied to the second-stage rocket to insert the payload onto a transfer orbit to the desired operational orbit. The most sensitive of the test cases was the degraded thrust case, yielding second-stage launch energies that were too low to achieve the radius of the desired operational orbit. The handling qualities of the airplane, as a first-stage vehicle, have also been investigated.

  17. Effect of a combination of flip and zooming stimuli on the performance of a visual brain-computer interface for spelling.

    PubMed

    Cheng, Jiao; Jin, Jing; Daly, Ian; Zhang, Yu; Wang, Bei; Wang, Xingyu; Cichocki, Andrzej

    2018-02-13

    Brain-computer interface (BCI) systems can allow their users to communicate with the external world by recognizing intention directly from their brain activity without the assistance of the peripheral motor nervous system. The P300-speller is one of the most widely used visual BCI applications. In previous studies, a flip stimulus (rotating the background area of the character) that was based on apparent motion, suffered from less refractory effects. However, its performance was not improved significantly. In addition, a presentation paradigm that used a "zooming" action (changing the size of the symbol) has been shown to evoke relatively higher P300 amplitudes and obtain a better BCI performance. To extend this method of stimuli presentation within a BCI and, consequently, to improve BCI performance, we present a new paradigm combining both the flip stimulus with a zooming action. This new presentation modality allowed BCI users to focus their attention more easily. We investigated whether such an action could combine the advantages of both types of stimuli presentation to bring a significant improvement in performance compared to the conventional flip stimulus. The experimental results showed that the proposed paradigm could obtain significantly higher classification accuracies and bit rates than the conventional flip paradigm (p<0.01).

  18. Top-down deactivation of interference from irrelevant spatial or verbal stimulus features.

    PubMed

    Frings, Christian; Wühr, Peter

    2014-11-01

    The selective-attention model of Houghton and Tipper (1994) assumes top-down deactivation of (conflicting) distractor representations as a mechanism of visual attention. Deactivation should produce an inverted-U-shaped activation function for distractor representations. In a recent study, Frings, Wentura, and Wühr (2012) tested this prediction in a variant of the flanker task in which a cue sometimes required participants to respond to the distractors rather than to the target. When reaction times and error rates were plotted as a function of the target-cue stimulus onset asynchrony, a quadratic trend emerged, consistent with the notion of distractor deactivation. However, in the flanker task, an alternative explanation for the quadratic trend in terms of attentional zooming is possible. The present experiments tested the deactivation account against the attentional-zooming account with the Stroop and the Simon task, in which attentional zooming should have minimal effects on distractor processing, because the target and distractor are presented at the same spatial location. Both experiments replicated the quadratic trend in the performance functions for responses to incongruent distractors, and additionally showed linear trends in the performance functions for responses to congruent distractors. These results provide additional support for the notion of top-down deactivation of distractor representations as a mechanism of visual selective attention.

  19. External versus internal triggers of bar formation in cosmological zoom-in simulations

    NASA Astrophysics Data System (ADS)

    Zana, Tommaso; Dotti, Massimo; Capelo, Pedro R.; Bonoli, Silvia; Haardt, Francesco; Mayer, Lucio; Spinoso, Daniele

    2018-01-01

    The emergence of a large-scale stellar bar is one of the most striking features in disc galaxies. By means of state-of-the-art cosmological zoom-in simulations, we study the formation and evolution of bars in Milky Way-like galaxies in a fully cosmological context, including the physics of gas dissipation, star formation and supernova feedback. Our goal is to characterize the actual trigger of the non-axisymmetric perturbation that leads to the strong bar observable in the simulations at z = 0, discriminating between an internal/secular and an external/tidal origin. To this aim, we run a suite of cosmological zoom-in simulations altering the original history of galaxy-satellite interactions at a time when the main galaxy, though already bar-unstable, does not feature any non-axisymmetric structure yet. We find that the main effect of a late minor merger and of a close fly-by is to delay the time of bar formation and those two dynamical events are not directly responsible for the development of the bar and do not alter significantly its global properties (e.g. its final extension). We conclude that, once the disc has grown to a mass large enough to sustain global non-axisymmetric modes, then bar formation is inevitable.

  20. High Fidelity System Simulation of Multiple Components in Support of the UEET Program

    NASA Technical Reports Server (NTRS)

    Plybon, Ronald C.; VanDeWall, Allan; Sampath, Rajiv; Balasubramaniam, Mahadevan; Mallina, Ramakrishna; Irani, Rohinton

    2006-01-01

    The High Fidelity System Simulation effort has addressed various important objectives to enable additional capability within the NPSS framework. The scope emphasized High Pressure Turbine and High Pressure Compressor components. Initial effort was directed at developing and validating intermediate fidelity NPSS model using PD geometry and extended to high-fidelity NPSS model by overlaying detailed geometry to validate CFD against rig data. Both "feedforward" and feedback" approaches of analysis zooming was employed to enable system simulation capability in NPSS. These approaches have certain benefits and applicability in terms of specific applications "feedback" zooming allows the flow-up of information from high-fidelity analysis to be used to update the NPSS model results by forcing the NPSS solver to converge to high-fidelity analysis predictions. This apporach is effective in improving the accuracy of the NPSS model; however, it can only be used in circumstances where there is a clear physics-based strategy to flow up the high-fidelity analysis results to update the NPSS system model. "Feed-forward" zooming approach is more broadly useful in terms of enabling detailed analysis at early stages of design for a specified set of critical operating points and using these analysis results to drive design decisions early in the development process.

  1. Increasing Access and Usability of Remote Sensing Data: The NASA Protected Area Archive

    NASA Technical Reports Server (NTRS)

    Geller, Gary N.

    2004-01-01

    Although remote sensing data are now widely available, much of it at low or no-cost, many managers of protected conservation areas do not have the expertise or tools to view or analyze it. Thus access to it by the protected area management community is effectively blocked. The Protected Area Archive will increase access to remote sensing data by creating collections of satellite images of protected areas and packaging them with simple-to-use visualization and analytical tools. The user can easily locate the area and image of interest on a map, then display, roam, and zoom the image. A set of simple tools will be provided so the user can explore the data and employ it to assist in management and monitoring of their area. The 'Phase 1 ' version requires only a Windows-based computer and basic computer skills, and may be of particular help to protected area managers in developing countries.

  2. Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data

    NASA Technical Reports Server (NTRS)

    Baxes, Gregory; Mixon, Brian; Linger, TIm

    2013-01-01

    Web-based geospatial client applications such as Google Earth and NASA World Wind must listen to data requests, access appropriate stored data, and compile a data response to the requesting client application. This process occurs repeatedly to support multiple client requests and application instances. Newer Web-based geospatial clients also provide user-interactive functionality that is dependent on fast and efficient server responses. With massively large datasets, server-client interaction can become severely impeded because the server must determine the best way to assemble data to meet the client applications request. In client applications such as Google Earth, the user interactively wanders through the data using visually guided panning and zooming actions. With these actions, the client application is continually issuing data requests to the server without knowledge of the server s data structure or extraction/assembly paradigm. A method for efficiently controlling the networked access of a Web-based geospatial browser to server-based datasets in particular, massively sized datasets has been developed. The method specifically uses the Keyhole Markup Language (KML), an Open Geospatial Consortium (OGS) standard used by Google Earth and other KML-compliant geospatial client applications. The innovation is based on establishing a dynamic cascading KML strategy that is initiated by a KML launch file provided by a data server host to a Google Earth or similar KMLcompliant geospatial client application user. Upon execution, the launch KML code issues a request for image data covering an initial geographic region. The server responds with the requested data along with subsequent dynamically generated KML code that directs the client application to make follow-on requests for higher level of detail (LOD) imagery to replace the initial imagery as the user navigates into the dataset. The approach provides an efficient data traversal path and mechanism that can be flexibly established for any dataset regardless of size or other characteristics. The method yields significant improvements in userinteractive geospatial client and data server interaction and associated network bandwidth requirements. The innovation uses a C- or PHP-code-like grammar that provides a high degree of processing flexibility. A set of language lexer and parser elements is provided that offers a complete language grammar for writing and executing language directives. A script is wrapped and passed to the geospatial data server by a client application as a component of a standard KML-compliant statement. The approach provides an efficient means for a geospatial client application to request server preprocessing of data prior to client delivery. Data is structured in a quadtree format. As the user zooms into the dataset, geographic regions are subdivided into four child regions. Conversely, as the user zooms out, four child regions collapse into a single, lower-LOD region. The approach provides an efficient data traversal path and mechanism that can be flexibly established for any dataset regardless of size or other characteristics.

  3. Precision monitoring of bridge deck curvature change during replacement.

    DOT National Transportation Integrated Search

    2016-05-01

    This project was focused on development and deployment of a system for monitoring vertical : displacement in bridge decks and bridge spans. The system uses high precision wireless inclinometer : sensors to monitor inclinations at various points of a ...

  4. Signal-to-noise analysis of a birefringent spectral zooming imaging spectrometer

    NASA Astrophysics Data System (ADS)

    Li, Jie; Zhang, Xiaotong; Wu, Haiying; Qi, Chun

    2018-05-01

    Study of signal-to-noise ratio (SNR) of a novel spectral zooming imaging spectrometer (SZIS) based on two identical Wollaston prisms is conducted. According to the theory of radiometry and Fourier transform spectroscopy, we deduce the theoretical equations of SNR of SZIS in spectral domain with consideration of the incident wavelength and the adjustable spectral resolution. An example calculation of SNR of SZIS is performed over 400-1000 nm. The calculation results indicate that SNR with different spectral resolutions of SZIS can be optionally selected by changing the spacing between the two identical Wollaston prisms. This will provide theoretical basis for the design, development and engineering of the developed imaging spectrometer for broad spectrum and SNR requirements.

  5. Complete description of the optical path difference of a novel spectral zooming imaging spectrometer

    NASA Astrophysics Data System (ADS)

    Li, Jie; Wu, Haiying; Qi, Chun

    2018-03-01

    A complete description of the optical path difference of a novel spectral zooming imaging spectrometer (SZIS) is presented. SZIS is designed based on two identical Wollaston prisms with an adjustable air gap. Thus, interferogram with arbitrary spectral resolution and great reduction of spectral image size can be conveniently formed to adapt to different application requirements. Ray tracing modeling in arbitrary incidence with a quasi-parallel-plate approximation scheme is proposed to analyze the optical path difference of SZIS. In order to know the characteristics of the apparatus, exact calculations of the corresponding spectral resolution and field of view are both derived and analyzed in detail. We also present a comparison of calculation and experiment to prove the validity of the theory.

  6. Replacing The Engine In Your Car While You Are Still Driving It [PowerPoint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjorklund, Eric A.

    The scope of the project included the following: install new network backbone, replace 201 MHz rf tubes, replace low-level rf system, replace timing system, replace industrial I/O system, replace beam synchronous data acquisition system, replace fast protect reporting system, new wire scanner hardware, and new beam position/phase monitor hardware--all of this to be done while continuing to deliver beam to users. Lessons learned, for anyone contemplating a similarly ambitious upgrade: You can’t replace the whole system at once. Some compatibility must be maintained between the old and new systems. Always have a way to fall back. Have sympathy for themore » operations staff. You will be surprised.« less

  7. Direct radiocarbon dating and genetic analyses on the purported Neanderthal mandible from the Monti Lessini (Italy).

    PubMed

    Talamo, Sahra; Hajdinjak, Mateja; Mannino, Marcello A; Fasani, Leone; Welker, Frido; Martini, Fabio; Romagnoli, Francesca; Zorzin, Roberto; Meyer, Matthias; Hublin, Jean-Jacques

    2016-07-08

    Anatomically modern humans replaced Neanderthals in Europe around 40,000 years ago. The demise of the Neanderthals and the nature of the possible relationship with anatomically modern humans has captured our imagination and stimulated research for more than a century now. Recent chronological studies suggest a possible overlap between Neanderthals and anatomically modern humans of more than 5,000 years. Analyses of ancient genome sequences from both groups have shown that they interbred multiple times, including in Europe. A potential place of interbreeding is the notable Palaeolithic site of Riparo Mezzena in Northern Italy. In order to improve our understanding of prehistoric occupation at Mezzena, we analysed the human mandible and several cranial fragments from the site using radiocarbon dating, ancient DNA, ZooMS and isotope analyses. We also performed a more detailed investigation of the lithic assemblage of layer I. Surprisingly we found that the Riparo Mezzena mandible is not from a Neanderthal but belonged to an anatomically modern human. Furthermore, we found no evidence for the presence of Neanderthal remains among 11 of the 13 cranial and post-cranial fragments re-investigated in this study.

  8. Direct radiocarbon dating and genetic analyses on the purported Neanderthal mandible from the Monti Lessini (Italy)

    PubMed Central

    Talamo, Sahra; Hajdinjak, Mateja; Mannino, Marcello A.; Fasani, Leone; Welker, Frido; Martini, Fabio; Romagnoli, Francesca; Zorzin, Roberto; Meyer, Matthias; Hublin, Jean-Jacques

    2016-01-01

    Anatomically modern humans replaced Neanderthals in Europe around 40,000 years ago. The demise of the Neanderthals and the nature of the possible relationship with anatomically modern humans has captured our imagination and stimulated research for more than a century now. Recent chronological studies suggest a possible overlap between Neanderthals and anatomically modern humans of more than 5,000 years. Analyses of ancient genome sequences from both groups have shown that they interbred multiple times, including in Europe. A potential place of interbreeding is the notable Palaeolithic site of Riparo Mezzena in Northern Italy. In order to improve our understanding of prehistoric occupation at Mezzena, we analysed the human mandible and several cranial fragments from the site using radiocarbon dating, ancient DNA, ZooMS and isotope analyses. We also performed a more detailed investigation of the lithic assemblage of layer I. Surprisingly we found that the Riparo Mezzena mandible is not from a Neanderthal but belonged to an anatomically modern human. Furthermore, we found no evidence for the presence of Neanderthal remains among 11 of the 13 cranial and post-cranial fragments re-investigated in this study. PMID:27389305

  9. Numerical Propulsion System Simulation

    NASA Technical Reports Server (NTRS)

    Naiman, Cynthia

    2006-01-01

    The NASA Glenn Research Center, in partnership with the aerospace industry, other government agencies, and academia, is leading the effort to develop an advanced multidisciplinary analysis environment for aerospace propulsion systems called the Numerical Propulsion System Simulation (NPSS). NPSS is a framework for performing analysis of complex systems. The initial development of NPSS focused on the analysis and design of airbreathing aircraft engines, but the resulting NPSS framework may be applied to any system, for example: aerospace, rockets, hypersonics, power and propulsion, fuel cells, ground based power, and even human system modeling. NPSS provides increased flexibility for the user, which reduces the total development time and cost. It is currently being extended to support the NASA Aeronautics Research Mission Directorate Fundamental Aeronautics Program and the Advanced Virtual Engine Test Cell (AVETeC). NPSS focuses on the integration of multiple disciplines such as aerodynamics, structure, and heat transfer with numerical zooming on component codes. Zooming is the coupling of analyses at various levels of detail. NPSS development includes capabilities to facilitate collaborative engineering. The NPSS will provide improved tools to develop custom components and to use capability for zooming to higher fidelity codes, coupling to multidiscipline codes, transmitting secure data, and distributing simulations across different platforms. These powerful capabilities extend NPSS from a zero-dimensional simulation tool to a multi-fidelity, multidiscipline system-level simulation tool for the full development life cycle.

  10. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    NASA Astrophysics Data System (ADS)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  11. Accelerated aortic imaging using small field of view imaging and electrocardiogram-triggered quadruple inversion recovery magnetization preparation.

    PubMed

    Peel, Sarah A; Hussain, Tarique; Cecelja, Marina; Abbas, Abeera; Greil, Gerald F; Chowienczyk, Philip; Spector, Tim; Smith, Alberto; Waltham, Matthew; Botnar, Rene M

    2011-11-01

    To accelerate and optimize black blood properties of the quadruple inversion recovery (QIR) technique for imaging the abdominal aortic wall. QIR inversion delays were optimized for different heart rates in simulations and phantom studies by minimizing the steady state magnetization of blood for T(1) = 100-1400 ms. To accelerate and improve black blood properties of aortic vessel wall imaging, the QIR prepulse was combined with zoom imaging and (a) "traditional" and (b) "trailing" electrocardiogram (ECG) triggering. Ten volunteers were imaged pre- and post-contrast administration using a conventional ECG-triggered double inversion recovery (DIR) and the two QIR implementations in combination with a zoom-TSE readout. The QIR implemented with "trailing" ECG-triggering resulted in consistently good blood suppression as the second inversion delay was timed during maximum systolic flow in the aorta. The blood signal-to-noise ratio and vessel wall to blood contrast-to-noise ratio, vessel wall sharpness, and image quality scores showed a statistically significant improvement compared with the traditional QIR implementation with and without ECG-triggering. We demonstrate that aortic vessel wall imaging can be accelerated with zoom imaging and that "trailing" ECG-triggering improves black blood properties of the aorta which is subject to motion and variable blood flow during the cardiac cycle. Copyright © 2011 Wiley Periodicals, Inc.

  12. Replacement of chemical oxygen demand (COD) with total organic carbon (TOC) for monitoring wastewater treatment performance to minimize disposal of toxic analytical waste.

    PubMed

    Dubber, Donata; Gray, Nicholas F

    2010-10-01

    Chemical oxygen demand (COD) is widely used for wastewater monitoring, design, modeling and plant operational analysis. However this method results in the production of hazardous wastes including mercury and hexavalent chromium. The study examined the replacement of COD with total organic carbon (TOC) for general performance monitoring by comparing their relationship with influent and effluent samples from 11 wastewater treatment plants. Biochemical oxygen demand (BOD5) was also included in the comparison as a control. The results show significant linear relationships between TOC, COD and BOD5 in settled (influent) domestic and municipal wastewaters, but only between COD and TOC in treated effluents. The study concludes that TOC can be reliably used for the generic replacement of both COD (COD=49.2+3.00*TOC) and BOD5 (BOD5=23.7+1.68*TOC) in influent wastewaters but only for COD (COD=7.25+2.99*TOC) in final effluents.

  13. Blood Glucose Monitoring Devices

    MedlinePlus

    ... of interferences ability to transmit data to a computer cost of the meter cost of the test ... Performance FDA expands indication for continuous glucose monitoring system, first to replace fingerstick testing for diabetes treatment ...

  14. Galactic Center Fly-in

    NASA Astrophysics Data System (ADS)

    Hanson, A.; Fu, C.-W.; Li, Y.; Frisch, P. C.

    2006-06-01

    Beginning with the familiar constellations of the night sky, we present a multispectral zoom into the core of the Milky Way Galaxy. After traveling over seven orders of magnitude in spatial scale, we discover the violent phenomena occurring within one light year of the Black Hole at the Galactic Core. This animated zoom includes data with wavelengths from radio to X-ray, and is based entirely on data or models that have been aligned at all spatial scales in order to provide a single continuous visual trip into the Center of the Milky Way Galaxy. The visualization challenge has been to align and choreograph data acquired over a wide range of wavelength and spatial scales, and obtain a new scientific as well as educational perspective of the dense core of our Galaxy.

  15. Image Viewer using Digital Imaging and Communications in Medicine (DICOM)

    NASA Astrophysics Data System (ADS)

    Baraskar, Trupti N.

    2010-11-01

    Digital Imaging and Communications in Medicine is a standard for handling, storing, printing, and transmitting information in medical imaging. The National Electrical Manufacturers Association holds the copyright to this standard. It was developed by the DICOM Standards committee. The other image viewers cannot collectively store the image details as well as the patient's information. So the image may get separated from the details, but DICOM file format stores the patient's information and the image details. Main objective is to develop a DICOM image viewer. The image viewer will open .dcm i.e. DICOM image file and also will have additional features such as zoom in, zoom out, black and white inverter, magnifier, blur, B/W inverter, horizontal and vertical flipping, sharpening, contrast, brightness and .gif converter are incorporated.

  16. Workshop on Transitioning Structural Health Monitoring Technology to Military Platforms

    DTIC Science & Technology

    2012-08-28

    sensors that can be multiplexed such as extrinsic Fabry -Perot interferometers (EFPI), but they are rarely used for structural monitoring. We have not...bureau, and outbreak monitoring by the US Centers for Disease Control (CDC).  One approach to data management is replacing conventional processing

  17. Technical note: Use of a digital and an optical Brix refractometer to estimate total solids in milk replacer solutions for calves.

    PubMed

    Floren, H K; Sischo, W M; Crudo, C; Moore, D A

    2016-09-01

    The Brix refractometer is used on dairy farms and calf ranches for colostrum quality (estimation of IgG concentration), estimation of serum IgG concentration in neonatal calves, and nonsalable milk evaluation of total solids for calf nutrition. Another potential use is to estimate the total solids concentrations of milk replacer mixes as an aid in monitoring feeding consistency. The purpose of this study was to evaluate the use of Brix refractometers to estimate total solids in milk replacer solutions and evaluate different replacer mixes for osmolality. Five different milk replacer powders (2 milk replacers with 28% crude protein and 25% fat and 3 with 22% crude protein and 20% fat) were mixed to achieve total solids concentrations from approximately 5.5 to 18%, for a total of 90 different solutions. Readings from both digital and optical Brix refractometers were compared with total solids. The 2 types of refractometers' readings correlated well with one another. The digital and optical Brix readings were highly correlated with the total solids percentage. A value of 1.08 to 1.47 would need to be added to the Brix reading to estimate the total solids in the milk replacer mixes with the optical and digital refractometers, respectively. Osmolality was correlated with total solids percentage of the mixes, but the relationship was different depending on the type of milk replacer. The Brix refractometer can be beneficial in estimating total solids concentration in milk replacer mixes to help monitor milk replacer feeding consistency. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Short- and Long-Term Lead Release after Partial Lead Service Line Replacements in a Metropolitan Water Distribution System.

    PubMed

    Deshommes, Elise; Laroche, Laurent; Deveau, Dominique; Nour, Shokoufeh; Prévost, Michèle

    2017-09-05

    Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (<2 yr) or old partial lead service line replacements (PLSLRs). Total and particulate lead concentrations were measured using repeat sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.

  19. Keeping it wild 2: An updated interagency strategy to monitor trends in wilderness character across the National Wilderness Preservation System

    Treesearch

    Peter Landres; Chris Barns; Steve Boutcher; Tim Devine; Peter Dratch; Adrienne Lindholm; Linda Merigliano; Nancy Roeper; Emily Simpson

    2015-01-01

    Keeping It Wild 2 is an interagency strategy to monitor trends in selected attributes of wilderness character based on lessons learned from 15 years of developing and implementing wilderness character monitoring across the National Wilderness Preservation System. This document updates and replaces Keeping It Wild: An Interagency Strategy for Monitoring Wilderness...

  20. The Ring Sculptor

    NASA Image and Video Library

    2006-09-08

    Prometheus zooms across the Cassini spacecraft field of view, attended by faint streamers and deep gores in the F ring. This movie sequence of five images shows the F ring shepherd moon shaping the ring inner edge

  1. Analysis of Patent Databases Using VxInsight

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BOYACK,KEVIN W.; WYLIE,BRIAN N.; DAVIDSON,GEORGE S.

    2000-12-12

    We present the application of a new knowledge visualization tool, VxInsight, to the mapping and analysis of patent databases. Patent data are mined and placed in a database, relationships between the patents are identified, primarily using the citation and classification structures, then the patents are clustered using a proprietary force-directed placement algorithm. Related patents cluster together to produce a 3-D landscape view of the tens of thousands of patents. The user can navigate the landscape by zooming into or out of regions of interest. Querying the underlying database places a colored marker on each patent matching the query. Automatically generatedmore » labels, showing landscape content, update continually upon zooming. Optionally, citation links between patents may be shown on the landscape. The combination of these features enables powerful analyses of patent databases.« less

  2. Optimizing pulse shaping and zooming for acceleration to high velocities and fusion neutron production on the Nike laser

    NASA Astrophysics Data System (ADS)

    Karasik, Max; Weaver, J. L.; Aglitskiy, Y.; Zalesak, S. T.; Velikovich, A. L.; Oh, J.; Obenschain, S. P.; Arikawa, Y.; Watari, T.

    2010-11-01

    We will present results from follow-on experiments to the record-high velocities of 1000 km/s achieved on Nike [Karasik et al., Phys. Plasmas 17, 056317 (2010) ], in which highly accelerated planar foils of deuterated polystyrene were made to collide with a witness foil to produce extreme shock pressures and result in heating of matter to thermonuclear temperatures. Still higher velocities and higher target densities are required for impact fast ignition. The aim of these experiments is shaping the driving pulse to minimize shock heating of the accelerated target and using the focal zoom capability of Nike to achieve higher densities and velocities. Spectroscopic measurements of electron temperature achieved upon impact will complement the neutron time-of-flight ion temperature measurement. Work is supported by US DOE and Office of Naval Research.

  3. Adaptive zooming in X-ray computed tomography.

    PubMed

    Dabravolski, Andrei; Batenburg, Kees Joost; Sijbers, Jan

    2014-01-01

    In computed tomography (CT), the source-detector system commonly rotates around the object in a circular trajectory. Such a trajectory does not allow to exploit a detector fully when scanning elongated objects. Increase the spatial resolution of the reconstructed image by optimal zooming during scanning. A new approach is proposed, in which the full width of the detector is exploited for every projection angle. This approach is based on the use of prior information about the object's convex hull to move the source as close as possible to the object, while avoiding truncation of the projections. Experiments show that the proposed approach can significantly improve reconstruction quality, producing reconstructions with smaller errors and revealing more details in the object. The proposed approach can lead to more accurate reconstructions and increased spatial resolution in the object compared to the conventional circular trajectory.

  4. A multi-camera system for real-time pose estimation

    NASA Astrophysics Data System (ADS)

    Savakis, Andreas; Erhard, Matthew; Schimmel, James; Hnatow, Justin

    2007-04-01

    This paper presents a multi-camera system that performs face detection and pose estimation in real-time and may be used for intelligent computing within a visual sensor network for surveillance or human-computer interaction. The system consists of a Scene View Camera (SVC), which operates at a fixed zoom level, and an Object View Camera (OVC), which continuously adjusts its zoom level to match objects of interest. The SVC is set to survey the whole filed of view. Once a region has been identified by the SVC as a potential object of interest, e.g. a face, the OVC zooms in to locate specific features. In this system, face candidate regions are selected based on skin color and face detection is accomplished using a Support Vector Machine classifier. The locations of the eyes and mouth are detected inside the face region using neural network feature detectors. Pose estimation is performed based on a geometrical model, where the head is modeled as a spherical object that rotates upon the vertical axis. The triangle formed by the mouth and eyes defines a vertical plane that intersects the head sphere. By projecting the eyes-mouth triangle onto a two dimensional viewing plane, equations were obtained that describe the change in its angles as the yaw pose angle increases. These equations are then combined and used for efficient pose estimation. The system achieves real-time performance for live video input. Testing results assessing system performance are presented for both still images and video.

  5. 75 FR 20073 - Repowering Assistance Payments to Eligible Biorefineries

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... be to encourage the use of renewable biomass as a replacement fuel source for fossil fuels used to.... Oversight and Monitoring F. Forms, Regulations, and Instructions G. Exception Authority H. Applicant... and encourage the use of renewable biomass to replace fossil fuels in the production of heat or power...

  6. Caught on Camera.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    2002-01-01

    Describes the benefits of and rules to be followed when using surveillance cameras for school security. Discusses various camera models, including indoor and outdoor fixed position cameras, pan-tilt zoom cameras, and pinhole-lens cameras for covert surveillance. (EV)

  7. Animation of MARDI Instrument

    NASA Image and Video Library

    2008-09-30

    This frame from an animation shows a zoom into the Mars Descent Imager MARDI instrument onboard NASA Phoenix Mars Lander. The Phoenix team will soon attempt to use a microphone on the MARDI instrument to capture sounds of Mars.

  8. Magnifying image intensifier

    NASA Technical Reports Server (NTRS)

    Vine, J.

    1977-01-01

    Coil assembly for zoom operation produces axial magnetic flux density that decreases in strength from photocathode to target. This results in magnification factor greater than unity. To extend magnification range, field is reversed in direction between object and image planes.

  9. Real-time near-IR imaging of laser-ablation crater evolution in dental enamel

    NASA Astrophysics Data System (ADS)

    Darling, Cynthia L.; Fried, Daniel

    2007-02-01

    We have shown that the enamel of the tooth is almost completely transparent near 1310-nm in the near-infrared and that near-IR (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue and for observing defects in the interior of the tooth. Lasers are now routinely used for many applications in dentistry including the ablation of dental caries. The objective of this study was to test the hypothesis that real-time NIR imaging can be used to monitor laser-ablation under varying conditions to assess peripheral thermal and transient-stress induced damage and to measure the rate and efficiency of ablation. Moreover, NIR imaging may have considerable potential for monitoring the removal of demineralized areas of the tooth during cavity preparations. Sound human tooth sections of approximately 3-mm thickness were irradiated by a CO II laser under varying conditions with and without a water spray. The incision area in the interior of each sample was imaged using a tungsten-halogen lamp with band-pass filter centered at 131--nm combined with an InGaAs focal plane array with a NIR zoom microscope in transillumination. Due to the high transparency of enamel at 1310-nm, laser-incisions were clearly visible to the dentin-enamel junction and crack formation, dehydration and irreversible thermal changes were observed during ablation. This study showed that there is great potential for near-IR imaging to monitor laser-ablation events in real-time to: assess safe laser operating parameters by imaging thermal and stress-induced damage, elaborate the mechanisms involved in ablation such as dehydration, and monitor the removal of demineralized enamel.

  10. MONITORING CULVERT PASSAGE OF JUVENILE SALMONIDS WITH PIT TAGS AND STATIONARY AND PORTABLE PIT-TAG READERS

    EPA Science Inventory

    Federal land management agencies in the PNW face increasing pressure to replace culverts that do not pass all life history stages of anadromous salmon and trout. Prioritization of culverts for replacement is often based on the physical parameters of culverts, and not on how fish...

  11. Exposing Black Holes Disguised in Dust

    NASA Image and Video Library

    2012-08-29

    This zoomed-in view of a portion of the all-sky survey from NASA Wide-field Infrared Survey Explorer shows a collection of quasar candidates shown in yellow circles. Quasars are supermassive black holes feeding off gas and dust.

  12. Extended Area Exit Pupil Viewer.

    DTIC Science & Technology

    1985-08-01

    viewing to normal Zoom-500 stereomicroscope viewing. Previous EAEP viewers typically have incorporated a spinning lenticular screen and associated...is uncorrected spherical aberration and astigmatism that limit image resolution. The complex optical path in the microscope also makes it inefficient

  13. Determination of Electron Optical Properties for Aperture Zoom Lenses Using an Artificial Neural Network Method.

    PubMed

    Isik, Nimet

    2016-04-01

    Multi-element electrostatic aperture lens systems are widely used to control electron or charged particle beams in many scientific instruments. By means of applied voltages, these lens systems can be operated for different purposes. In this context, numerous methods have been performed to calculate focal properties of these lenses. In this study, an artificial neural network (ANN) classification method is utilized to determine the focused/unfocused charged particle beam in the image point as a function of lens voltages for multi-element electrostatic aperture lenses. A data set for training and testing of ANN is taken from the SIMION 8.1 simulation program, which is a well known and proven accuracy program in charged particle optics. Mean squared error results of this study indicate that the ANN classification method provides notable performance characteristics for electrostatic aperture zoom lenses.

  14. Variable diameter CO2 laser ring-cutting system adapted to a zoom microscope for applications on polymer tapes.

    PubMed

    Förster, Erik; Bohnert, Patrick; Kraus, Matthias; Kilper, Roland; Müller, Ute; Buchmann, Martin; Brunner, Robert

    2016-11-20

    This paper presents the conception and implementation of a variable diameter ring-cutting system for a CO2 laser with a working wavelength of 10.6 μm. The laser-cutting system is adapted to an observation zoom microscope for combined use and is applicable for the extraction of small circular areas from polymer films, such as forensic adhesive tapes in a single shot. As an important characteristic for our application, the variable diameter ring-cutting system provides telecentricity in the target area. Ring diameters are continuously tunable between 500 μm and 2 mm. A minimum width of less than 20 μm was found for the ring profile edge. The basic characteristics of the system, including telecentricity, were experimentally evaluated and demonstrated by cutting experiments on different polymer tapes and further exemplary samples.

  15. Use of zooming and pulseshaping for acceleration to high velocities and fusion neutron production on the Nike laser

    NASA Astrophysics Data System (ADS)

    Karasik, Max; Weaver, J. L.; Aglitskiy, Y.; Kehne, D. M.; Zalesak, S. T.; Velikovich, A. L.; Oh, J.; Obenschain, S. P.; Arikawa, Y.

    2011-10-01

    We will present results from follow-on experiments to the record-high velocities of 1000 km/s achieved on Nike [Karasik et al, Phys. Plasmas 17, 056317(2010)], in which highly accelerated planar foils of deuterated polystyrene were made to collide with a witness foil to produce ~ 1 Gbar shock pressures and result in heating of matter to thermonuclear temperatures. Still higher velocities and higher target densities are required for impact fast ignition. The aim of these experiments is using the focal zoom capability of Nike and shaping the driving pulse to minimize shock heating of the accelerated target to achieve higher densities and velocities. In-flight target density is inferred from target heating upon collision via DD neutron time-of-flight ion temperature measurement. Work is supported by US DOE (NNSA) and Office of Naval Research. SAIC

  16. Obscura telescope with a MEMS micromirror array for space observation of transient luminous phenomena or fast-moving objects.

    PubMed

    Park, J H; Garipov, G K; Jeon, J A; Khrenov, B A; Kim, J E; Kim, M; Kim, Y K; Lee, C-H; Lee, J; Na, G W; Nam, S; Park, I H; Park, Y-S

    2008-12-08

    We introduce a novel telescope consisting of a pinhole-like camera with rotatable MEMS micromirrors substituting for pinholes. The design is ideal for observations of transient luminous phenomena or fast-moving objects, such as upper atmospheric lightning and bright gamma ray bursts. The advantage of the MEMS "obscura telescope" over conventional cameras is that it is capable both of searching for events over a wide field of view, and fast zooming to allow detailed investigation of the structure of events. It is also able to track the triggering object to investigate its space-time development, and to center the interesting portion of the image on the photodetector array. We present the proposed system and the test results for the MEMS obscura telescope which has a field of view of 11.3 degrees, sixteen times zoom-in and tracking within 1 ms. (c) 2008 Optical Society of America

  17. Monitoring the vaccine cold chain.

    PubMed

    Cheriyan, E

    1993-11-01

    Maintaining the vaccine cold chain is an essential part of a successful immunisation programme. A continuous electronic temperature monitor helped to identify breaks in the cold chain in the community and the study led to the issue of proper guidelines and replacement of faulty equipment.

  18. Precision monitoring of bridge deck curvature change during replacement : research summary.

    DOT National Transportation Integrated Search

    2016-05-01

    The goal of this project was to introduce a novel method for long term : monitoring of vertical displacement and change in curvature in highway bridge : decks. The method used an array of high precision wireless inclination (tilt) : sensors to consta...

  19. Successfully performing a university student's role despite disabilities: challenges of an inclusive environment and appropriate task modification.

    PubMed

    Rochette, Annie; Loiselle, Frederic

    2012-01-01

    To reflect on what it means to successfully perform a university student's role despite the presence of impairments. The Disability Creation Process (DCP) model is used as a tool to zoom in the different activities and tasks required for a successful education as well as to describe how the social and physical environment can be as inclusive as possible to compensate for different impairments. One activity in the student's role (reading) is used to illustrate and reflect on potential challenges in compensating for impairments by way of environmental or task modifications. The student's role is a complex one, characterized by different actions such as getting admitted, moving around, attending courses, studying and participating in student life. Environmental factors or time can facilitate or impede the level of participation in the education domain. One challenge may be to differentiate between compensation for learning (processes) as compared to outcomes (competency level for future employment) as well as to determine how much assistance is acceptable. Intuitive single-case analysis should be replaced by a systematic analysis relying on a conceptual model such as the DCP. To avoid discrimination and to ensure transparency, acceptable amount of compensation for an activity should be defined.

  20. Pushing down the low-mass halo concentration frontier with the Lomonosov cosmological simulations

    NASA Astrophysics Data System (ADS)

    Pilipenko, Sergey V.; Sánchez-Conde, Miguel A.; Prada, Francisco; Yepes, Gustavo

    2017-12-01

    We introduce the Lomonosov suite of high-resolution N-body cosmological simulations covering a full box of size 32 h-1 Mpc with low-mass resolution particles (2 × 107 h-1 M⊙) and three zoom-in simulations of overdense, underdense and mean density regions at much higher particle resolution (4 × 104 h-1 M⊙). The main purpose of this simulation suite is to extend the concentration-mass relation of dark matter haloes down to masses below those typically available in large cosmological simulations. The three different density regions available at higher resolution provide a better understanding of the effect of the local environment on halo concentration, known to be potentially important for small simulation boxes and small halo masses. Yet, we find the correction to be small in comparison with the scatter of halo concentrations. We conclude that zoom simulations, despite their limited representativity of the volume of the Universe, can be effectively used for the measurement of halo concentrations at least at the halo masses probed by our simulations. In any case, after a precise characterization of this effect, we develop a robust technique to extrapolate the concentration values found in zoom simulations to larger volumes with greater accuracy. Altogether, Lomonosov provides a measure of the concentration-mass relation in the halo mass range 107-1010 h-1 M⊙ with superb halo statistics. This work represents a first important step to measure halo concentrations at intermediate, yet vastly unexplored halo mass scales, down to the smallest ones. All Lomonosov data and files are public for community's use.

  1. Patient monitoring in the operating theatre.

    PubMed

    Forrest, A L; Douglas, D M; Rimmer, A R

    1976-09-01

    Anaesthetised patients are monitored to ensure their safety. Simple clinical observations must not be replaced by electronic instruments--these provide an extension of the clinical senses. The choice of parameters for monitoring is discussed. The design of the Ninewells main operating theatre suite is described. An 8-channel bourne in the base of the theatre table conveys patient signals to a 4-channel recorder in a monitoring laboratory. Outputs are displayed on a wall mounted display in theatre. Two-way speech intercommunication exists with monitoring technician and students.

  2. The PartoPen: Using Digital Pen Technology to Improve Maternal Labor Monitoring in the Developing World

    ERIC Educational Resources Information Center

    Underwood, Heather Marie

    2013-01-01

    This dissertation presents the PartoPen, a new approach to addressing maternal labor monitoring challenges in developing countries. The PartoPen is a hardware and software system that uses digital pen technology to enhance, rather than replace, the paper-based labor monitoring tool known as the partograph. In the developing world, correct use of…

  3. Zooming in on heat at Baghdad Sulcus

    NASA Image and Video Library

    2010-02-23

    This map shows a dramatically improved view of heat radiation from a warm fissure near the south pole of Saturn icy moon Enceladus. It was obtained by NASA Cassini spacecraft during its Nov. 21, 2009, flyby of that moon.

  4. The Examination of the Aluminum Alloy 7017 as a Replacement for the Aluminum Alloy 7039 in Lightweight Armor Systems

    DTIC Science & Technology

    2016-07-01

    ORGANIZATION REPORT NUMBER ARL-TR-7727 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10 . SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S...of 0.50-cal. FSP vs. AA7017 plate at 0° .......................................................................................................... 10 ... 10 List of Tables Table 1 Chemical composition, weight percent

  5. Before the Deep Impact Collision

    NASA Image and Video Library

    2011-02-18

    This series of images shows the area where NASA Deep Impact probe collided with the surface of comet Tempel 1 in 2005. The view zooms in as the images progress from top left to right, and then bottom left to right.

  6. Sigma Periodic Table Browse

    Science.gov Websites

    library. • Fission yields. • Pre-calculated integral quantities. • Improved zooming. New in version 3.0 , ENDF/B-VI.8 libraries. • Neutron cross section distributions (MF=3). • Experimental data in EXFOR

  7. Pacemaker remote monitoring in the pediatric population: is it a real solution?

    PubMed

    Leoni, Loira; Padalino, Massimo; Biffanti, Roberta; Ferretto, Sonia; Vettor, Giulia; Corrado, Domenico; Stellin, Giovanni; Milanesi, Ornella; Iliceto, Sabino

    2015-05-01

    Clinical utility of remote monitoring of implantable cardiac devices has been previously demonstrated in several trials in the adult population. The aim of this study was to assess the clinical utility of remote monitoring in a pediatric population undergoing pacemakers implantation. The study population included 73 consecutive pediatric patients who received an implantable pacemaker. The remote device check was programmed for every 3 months and all patients had a yearly out-patient visit. Data on device-related events, hospitalization, and other clinical information were collected during remote checks and out-patient visits. During a mean follow-up of 18 ± 10 months, 470 remote transmissions were collected and analyzed. Two deaths were reported. Eight transmissions (1.7%) triggered an urgent out-patient visit. Twenty percent of transmissions reported evidence of significant clinical or technical events. All young patients and their families were very satisfied when using remote monitoring to replace out-patient visits. The ease in use, together with satisfaction and acceptance of remote monitoring in pediatric patients, brought very good results. The remote management of our pediatric population was safe and remote monitoring adequately replaced the periodic out-patient device checks without compromising patient safety. ©2015 Wiley Periodicals, Inc.

  8. Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 CP810 Sound Processor.

    PubMed

    Dillier, Norbert; Lai, Wai Kong

    2015-06-11

    The Nucleus(®) 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of -8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.

  9. Installation Boundary Fence Replacement: Upland Areas: Environmental Assessment

    DTIC Science & Technology

    2004-05-27

    Moody Air Force Base, GA Environmental Assessment Installation Boundary Fence Replacement INSTALLATION BOUNDARY...347 CES/CEV),3485 Georgia Street,Moody AFB, GA ,31699 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Moody Air Force Base, GA Environmental Assessment

  10. The Trifid Nebula: Stellar Sibling Rivalry

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A zoom into the Trifid Nebula starts with ground-based observations and ends with a Hubble Space Telescope (HST) image. Another HST image shows star formation in the nebula and the video concludes with a ground-based image of the Trifid Nebula.

  11. 40 CFR 60.144a - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... replaced with the following instructions for recording observations and reducing data: (i) Section 2.4... follows: (1) For devices that monitor and record the exhaust ventilation rate, compare velocity readings recorded by the monitoring device against the velocity readings obtained by Method 2. Take Method 2...

  12. 40 CFR 60.144a - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... replaced with the following instructions for recording observations and reducing data: (i) Section 2.4... follows: (1) For devices that monitor and record the exhaust ventilation rate, compare velocity readings recorded by the monitoring device against the velocity readings obtained by Method 2. Take Method 2...

  13. Data base to compare calculations and observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tichler, J.L.

    Meteorological and climatological data bases were compared with known tritium release points and diffusion calculations to determine if calculated concentrations could replace measure concentrations at the monitoring stations. Daily tritium concentrations were monitored at 8 stations and 16 possible receptors. Automated data retrieval strategies are listed. (PSB)

  14. Application of programmable logic controllers to space simulation

    NASA Technical Reports Server (NTRS)

    Sushon, Janet

    1992-01-01

    Incorporating a state-of-the-art process control and instrumentation system into a complex system for thermal vacuum testing is discussed. The challenge was to connect several independent control systems provided by various vendors to a supervisory computer. This combination will sequentially control and monitor the process, collect the data, and transmit it to color a graphic system for subsequent manipulation. The vacuum system upgrade included: replacement of seventeen diffusion pumps with eight cryogenic pumps and one turbomolecular pump, replacing a relay based control system, replacing vacuum instrumentation, and upgrading the data acquisition system.

  15. 30 CFR 27.32 - Tests to determine performance of the system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.32... durability of a methane-monitoring system. The tests shall be conducted as follows: 2 Normal replacements and... gas (containing a high percentage of methane) is a satisfactory substitute for pure methane in these...

  16. Fault detection monitor circuit provides ''self-heal capability'' in electronic modules - A concept

    NASA Technical Reports Server (NTRS)

    Kennedy, J. J.

    1970-01-01

    Self-checking technique detects defective solid state modules used in electronic test and checkout instrumentation. A ten bit register provides failure monitor and indication for 1023 comparator circuits, and the automatic fault-isolation capability permits the electronic subsystems to be repaired by replacing the defective module.

  17. Frontotemporal Dementias: Diagnosis

    MedlinePlus

    ... Have questions from the start? Call AFTD’s toll-free HelpLine at 866-507-7222 , or contact us by email at info@theaftd.org . For Persons Diagnosed AFTD holds a monthly online support group using the internet video platform Zoom. Contact the HelpLine at 866- ...

  18. Equipment and New Products

    ERIC Educational Resources Information Center

    Poitras, Adrian W., Ed.

    1973-01-01

    The following items are discussed: Digital Counters and Readout Devices, Automatic Burette Outfits, Noise Exposure System, Helium-Cadmium Laser, New pH Buffers and Flip-Top Dispenser, Voltage Calibrator Transfer Standard, Photomicrographic Stereo Zoom Microscope, Portable pH Meter, Micromanipulators, The Snuffer, Electronic Top-Loading Balances,…

  19. Field Demonstration of Multi-Sensor Technology for Condition Assessment of Wastewater Collection Systems (Abstract)

    EPA Science Inventory

    The purpose of the field demonstration program is to gather technically reliable cost and performance information on selected condition assessment technologies under defined field conditions. The selected technologies include zoom camera, focused electrode leak location (FELL), ...

  20. ZOOMsci Activity Guide.

    ERIC Educational Resources Information Center

    Wade, Meredith

    This activity guide is based on the Public Broadcasting System's (PBS) program "ZOOM." It is designed for educators with activities that are categorized into three themes: (1) Things That Go, which includes "Air" which explores air pressure, "Rubber Bands" which discovers the potential energy of rubber bands,…

  1. Active Optical Zoom for Tracking

    DTIC Science & Technology

    2008-09-01

    optical system. 2. Current Setup Deformable Flat Two Deformable Flat Figure 1. Zemax lens design layout and experimental layout on the...optical bench. Figure 1 is a ZEMAX design and setup on the optical bench of two Deformable Mirrors (DMs) from OKO technologies. These mirrors have

  2. Program Manipulates Plots For Effective Display

    NASA Technical Reports Server (NTRS)

    Bauer, F.; Downing, J.

    1990-01-01

    Windowed Observation of Relative Motion (WORM) computer program primarily intended for generation of simple X-Y plots from data created by other programs. Enables user to label, zoom, and change scales of various plots. Three-dimensional contour and line plots provided. Written in PASCAL.

  3. Survey of patient-oriented total hip replacement information on the World Wide Web.

    PubMed

    Mabrey, J D

    2000-12-01

    The author conducted an informal survey of materials relating to diseases of the hip and total hip replacement as they appeared on the World Wide Web. The results varied depending on the key words used: hip and replacement yielded 1,818 matches; total hip replacement yielded 1,740 matches; hip replacement yielded 4,565 sites; and hip surgery yielded 1,073 sites. The number of sites for total hip replacement was observed to increase with time, having found an additional 30 sites from an identical search performed only 6 weeks earlier. The nature and quality of these sites varied from well-organized and informative, to personal testaments, to obvious commercial endeavors. Overall, this survey found an abundance of material regarding the hip and hip replacements on the World Wide Web, but orthopaedic societies need to take a more active role in constructing, maintaining, and monitoring these sites to best serve the needs of their patients and their members.

  4. Cine-servo lens technology for 4K broadcast and cinematography

    NASA Astrophysics Data System (ADS)

    Nurishi, Ryuji; Wakazono, Tsuyoshi; Usui, Fumiaki

    2015-09-01

    Central to the rapid evolution of 4K image capture technology in the past few years, deployment of large-format cameras with Super35mm Single Sensors is increasing in TV production for diverse shows such as dramas, documentaries, wildlife, and sports. While large format image capture has been the standard in the cinema world for quite some time, the recent experiences within the broadcast industry have revealed a variety of requirement differences for large format lenses compared to those of the cinema industry. A typical requirement for a broadcast lens is a considerably higher zoom ratio in order to avoid changing lenses in the middle of a live event, which is mostly not the case for traditional cinema productions. Another example is the need for compact size, light weight, and servo operability for a single camera operator shooting in a shoulder-mount ENG style. On the other hand, there are new requirements that are common to both worlds, such as smooth and seamless change in angle of view throughout the long zoom range, which potentially offers new image expression that never existed in the past. This paper will discuss the requirements from the two industries of cinema and broadcast, while at the same time introducing the new technologies and new optical design concepts applied to our latest "CINE-SERVO" lens series which presently consists of two models, CN7x17KAS-S and CN20x50IAS-H. It will further explain how Canon has realized 4K optical performance and fast servo control while simultaneously achieving compact size, light weight and high zoom ratio, by referring to patent-pending technologies such as the optical power layout, lens construction, and glass material combinations.

  5. GenExp: an interactive web-based genomic DAS client with client-side data rendering.

    PubMed

    Gel Moreno, Bernat; Messeguer Peypoch, Xavier

    2011-01-01

    The Distributed Annotation System (DAS) offers a standard protocol for sharing and integrating annotations on biological sequences. There are more than 1000 DAS sources available and the number is steadily increasing. Clients are an essential part of the DAS system and integrate data from several independent sources in order to create a useful representation to the user. While web-based DAS clients exist, most of them do not have direct interaction capabilities such as dragging and zooming with the mouse. Here we present GenExp, a web based and fully interactive visual DAS client. GenExp is a genome oriented DAS client capable of creating informative representations of genomic data zooming out from base level to complete chromosomes. It proposes a novel approach to genomic data rendering and uses the latest HTML5 web technologies to create the data representation inside the client browser. Thanks to client-side rendering most position changes do not need a network request to the server and so responses to zooming and panning are almost immediate. In GenExp it is possible to explore the genome intuitively moving it with the mouse just like geographical map applications. Additionally, in GenExp it is possible to have more than one data viewer at the same time and to save the current state of the application to revisit it later on. GenExp is a new interactive web-based client for DAS and addresses some of the short-comings of the existing clients. It uses client-side data rendering techniques resulting in easier genome browsing and exploration. GenExp is open source under the GPL license and it is freely available at http://gralggen.lsi.upc.edu/recerca/genexp.

  6. Open source tools for management and archiving of digital microscopy data to allow integration with patient pathology and treatment information.

    PubMed

    Khushi, Matloob; Edwards, Georgina; de Marcos, Diego Alonso; Carpenter, Jane E; Graham, J Dinny; Clarke, Christine L

    2013-02-12

    Virtual microscopy includes digitisation of histology slides and the use of computer technologies for complex investigation of diseases such as cancer. However, automated image analysis, or website publishing of such digital images, is hampered by their large file sizes. We have developed two Java based open source tools: Snapshot Creator and NDPI-Splitter. Snapshot Creator converts a portion of a large digital slide into a desired quality JPEG image. The image is linked to the patient's clinical and treatment information in a customised open source cancer data management software (Caisis) in use at the Australian Breast Cancer Tissue Bank (ABCTB) and then published on the ABCTB website (http://www.abctb.org.au) using Deep Zoom open source technology. Using the ABCTB online search engine, digital images can be searched by defining various criteria such as cancer type, or biomarkers expressed. NDPI-Splitter splits a large image file into smaller sections of TIFF images so that they can be easily analysed by image analysis software such as Metamorph or Matlab. NDPI-Splitter also has the capacity to filter out empty images. Snapshot Creator and NDPI-Splitter are novel open source Java tools. They convert digital slides into files of smaller size for further processing. In conjunction with other open source tools such as Deep Zoom and Caisis, this suite of tools is used for the management and archiving of digital microscopy images, enabling digitised images to be explored and zoomed online. Our online image repository also has the capacity to be used as a teaching resource. These tools also enable large files to be sectioned for image analysis. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5330903258483934.

  7. A micro-optical system for endoscopy based on mechanical compensation paradigm using miniature piezo-actuation.

    PubMed

    Cerveri, Pietro; Zazzarini, Cynthia Corinna; Patete, Paolo; Baroni, Guido

    2014-06-01

    The goal of the study was to investigate the feasibility of a novel miniaturized optical system for endoscopy. Fostering the mechanical compensation paradigm, the modeled optical system, composed by 14 lenses, separated in 4 different sets, had a total length of 15.55mm, an effective focal length ranging from 1.5 to 4.5mm with a zoom factor of about 2.8×, and an angular field of view up to 56°. Predicted maximum lens travel was less than 3.5mm. The consistency of the image plane height across the magnification range testified the zoom capability. The maximum predicted achromatic astigmatism, transverse spherical aberration, longitudinal spherical aberration and relative distortion were less than or equal to 25μm, 15μm, 35μm and 12%, respectively. Tests on tolerances showed that the manufacturing and opto-mechanics mounting are critical as little deviations from design dramatically decrease the optical performances. However, recent micro-fabrication technology can guarantee tolerances close to nominal design. A closed-loop actuation unit, devoted to move the zoom and the focus lens sets, was implemented adopting miniaturized squiggle piezo-motors and magnetic position encoders based on Hall effect. Performance results, using a prototypical test board, showed a positioning accuracy of less than 5μm along a lens travel path of 4.0mm, which was in agreement with the lens set motion features predicted by the analysis. In conclusion, this study demonstrated the feasibility of the optical design and the viability of the actuation approach while tolerances must be carefully taken into account. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. ME8373 Spring 2015 ICME Proposal ICME Analysis of Fatigue Crack Growth Through a Weld in SA-516 Grade 70 Plate

    NASA Technical Reports Server (NTRS)

    Woods, Jody L.

    2015-01-01

    This paper describes work accomplished to predict the service life of a flexure joint design which is a component of a diffuser duct in the A3 Test Stand, an altitude simulation rocket engine test facility at NASA's Stennis Space Center. The duct has two pressure shells separated by cooling water passages and connected by stiffening ribs and flexure joints. Rocket exhaust flows within the duct and heats the inner pressure shell while the outer pressure shell remains at ambient temperature. The flexure joints allow for differential thermal expansion of the inner and outer pressure shells and are subject to in-service loading by this thermal expansion along with water pressure in the cooling water passage, atmospheric pressure outside the duct, near vacuum conditions within the duct, and vibrational loads from operation of the facility and rocket engine. Figure 1 shows a schematic axisymmetric cross section of the diffuser pressure shells and flexure joints with a zoomed in view of the flexure joint. The flexure joints are expected to eventually fail by fatigue cracking leading to leaks from the cooling water passages to the outside. The zoomed in view in Figure 1 indicates where cracking is expected to occur, namely through a weld bead between two plates of SA-516 Grade 70 steel. This weld bead acts as the fulcrum of the flexure joint and it is clear from inspection of the geometry and loading represented in the zoomed in portion of Figure 1 that inherent in the design there is a severe notch formed between the flexure plate, weld bead, and stiffening ring that will be the site of crack initiation and location from which the crack grows to the outer surface of the weld bead.

  9. Zoomed MRI Guided by Combined EEG/MEG Source Analysis: A Multimodal Approach for Optimizing Presurgical Epilepsy Work-up and its Application in a Multi-focal Epilepsy Patient Case Study.

    PubMed

    Aydin, Ü; Rampp, S; Wollbrink, A; Kugel, H; Cho, J -H; Knösche, T R; Grova, C; Wellmer, J; Wolters, C H

    2017-07-01

    In recent years, the use of source analysis based on electroencephalography (EEG) and magnetoencephalography (MEG) has gained considerable attention in presurgical epilepsy diagnosis. However, in many cases the source analysis alone is not used to tailor surgery unless the findings are confirmed by lesions, such as, e.g., cortical malformations in MRI. For many patients, the histology of tissue resected from MRI negative epilepsy shows small lesions, which indicates the need for more sensitive MR sequences. In this paper, we describe a technique to maximize the synergy between combined EEG/MEG (EMEG) source analysis and high resolution MRI. The procedure has three main steps: (1) construction of a detailed and calibrated finite element head model that considers the variation of individual skull conductivities and white matter anisotropy, (2) EMEG source analysis performed on averaged interictal epileptic discharges (IED), (3) high resolution (0.5 mm) zoomed MR imaging, limited to small areas centered at the EMEG source locations. The proposed new diagnosis procedure was then applied in a particularly challenging case of an epilepsy patient: EMEG analysis at the peak of the IED coincided with a right frontal focal cortical dysplasia (FCD), which had been detected at standard 1 mm resolution MRI. Of higher interest, zoomed MR imaging (applying parallel transmission, 'ZOOMit') guided by EMEG at the spike onset revealed a second, fairly subtle, FCD in the left fronto-central region. The evaluation revealed that this second FCD, which had not been detectable with standard 1 mm resolution, was the trigger of the seizures.

  10. GenExp: An Interactive Web-Based Genomic DAS Client with Client-Side Data Rendering

    PubMed Central

    Gel Moreno, Bernat; Messeguer Peypoch, Xavier

    2011-01-01

    Background The Distributed Annotation System (DAS) offers a standard protocol for sharing and integrating annotations on biological sequences. There are more than 1000 DAS sources available and the number is steadily increasing. Clients are an essential part of the DAS system and integrate data from several independent sources in order to create a useful representation to the user. While web-based DAS clients exist, most of them do not have direct interaction capabilities such as dragging and zooming with the mouse. Results Here we present GenExp, a web based and fully interactive visual DAS client. GenExp is a genome oriented DAS client capable of creating informative representations of genomic data zooming out from base level to complete chromosomes. It proposes a novel approach to genomic data rendering and uses the latest HTML5 web technologies to create the data representation inside the client browser. Thanks to client-side rendering most position changes do not need a network request to the server and so responses to zooming and panning are almost immediate. In GenExp it is possible to explore the genome intuitively moving it with the mouse just like geographical map applications. Additionally, in GenExp it is possible to have more than one data viewer at the same time and to save the current state of the application to revisit it later on. Conclusions GenExp is a new interactive web-based client for DAS and addresses some of the short-comings of the existing clients. It uses client-side data rendering techniques resulting in easier genome browsing and exploration. GenExp is open source under the GPL license and it is freely available at http://gralggen.lsi.upc.edu/recerca/genexp. PMID:21750706

  11. Examining the Usability of Touch Screen Gestures for Older and Younger Adults.

    PubMed

    Gao, Qin; Sun, Qiqi

    2015-08-01

    We examined the usability issues associated with four touch screen gestures (clicking, dragging, zooming, and rotating) among older and younger users. It is especially important to accommodate older users' characteristics to ensure the accessibility of information and services that are important to their quality of life. Forty older and 40 younger participants completed four experiments, each of which focused on one gesture. The effects of age, type of touch screen (surface acoustic wave vs. optical), inclination angle (30°, 45°, 60°, and 75°), and user interface factors (clicking: button size and spacing; dragging: dragging direction and distance; zooming: design of zooming gesture; rotating: design of rotating gesture) on user performance and satisfaction were examined. Button sizes that are larger than 15.9 × 9.0 mm led to better performance and higher satisfaction. The effect of spacing was significant only when the button size was notably small or large. Rightward and downward dragging were preferred to leftward and upward dragging, respectively. The younger participants favored direct manipulation gestures using multiple fingers, whereas the older participants preferred the click-to design. The older participants working with large inclination angles of 60° to 75° reported a higher level of satisfaction than the older participants working with smaller angles. We proposed a set of design guidelines for touch screen user interfaces and discussed implications for the selection of appropriate technology and the configuration of the workspace. The implications are useful for the design of large touch screen applications, such as desktop computers, information kiosks, and health care support systems. © 2015, Human Factors and Ergonomics Society.

  12. Replacing the AMOR with the miniDOAS in the ammonia monitoring network in the Netherlands

    NASA Astrophysics Data System (ADS)

    Berkhout, Augustinus J. C.; Swart, Daan P. J.; Volten, Hester; Gast, Lou F. L.; Haaima, Marty; Verboom, Hans; Stefess, Guus; Hafkenscheid, Theo; Hoogerbrugge, Ronald

    2017-11-01

    In this paper we present the continued development of the miniDOAS, an active differential optical absorption spectroscopy (DOAS) instrument used to measure ammonia concentrations in ambient air. The miniDOAS has been adapted for use in the Dutch National Air Quality Monitoring Network. The miniDOAS replaces the life-expired continuous-flow denuder ammonia monitor (AMOR). From September 2014 to December 2015, both instruments measured in parallel before the change from AMOR to miniDOAS was made. The instruments were deployed at six monitoring stations throughout the Netherlands. We report on the results of this intercomparison. Both instruments show a good uptime of ca. 90 %, adequate for an automatic monitoring network. Although both instruments produce 1 min values of ammonia concentrations, a direct comparison on short timescales such as minutes or hours does not give meaningful results because the AMOR response to changing ammonia concentrations is slow. Comparisons between daily and monthly values show good agreement. For monthly averages, we find a small average offset of 0.65 ± 0.28 µg m-3 and a slope of 1.034 ± 0.028, with the miniDOAS measuring slightly higher than the AMOR. The fast time resolution of the miniDOAS makes the instrument suitable not only for monitoring but also for process studies.

  13. Cost–consequence analysis of daily continuous remote monitoring of implantable cardiac defibrillator and resynchronization devices in the UK

    PubMed Central

    Burri, Haran; Sticherling, Christian; Wright, David; Makino, Koji; Smala, Antje; Tilden, Dominic

    2013-01-01

    Aims The need for ongoing and lifelong follow-up (FU) of patients with cardiac implantable electric devices (CIED) requires significant resources. Remote CIED management has been established as a safe alternative to conventional periodical in-office FU (CFU). An economic model compares the long-term cost and consequences of using daily Home Monitoring® (HM) instead of CFU. Methods and results A cost–consequence evaluation comparing HM vs. CFU was performed using a Markov cohort model and data relating to events and costs identified via a systematic review of the literature. The model is conservative, without assuming a reduction of cardiovascular events by HM such as decompensated heart failure or mortality, or considering cost savings such as for transportation. Also cost savings due to an improved timing of elective device replacement, and fewer FU visits needed in patients near device replacement are not considered. Over 10 years, HM is predicted to be cost neutral at about GBP 11 500 per patient in either treatment arm, with all costs for the initial investment into HM and fees for ongoing remote monitoring included. Fewer inappropriate shocks (−51%) reduce the need for replacing devices for battery exhaustion (−7%); the number of FU visits is predicted to be halved by HM. Conclusion From a UK National Health Service perspective, HM is cost neutral over 10 years. This is mainly accomplished by reducing the number of battery charges and inappropriate shocks, resulting in fewer device replacements, and by reducing the number of in-clinic FU visits. PMID:23599169

  14. Cost-consequence analysis of daily continuous remote monitoring of implantable cardiac defibrillator and resynchronization devices in the UK.

    PubMed

    Burri, Haran; Sticherling, Christian; Wright, David; Makino, Koji; Smala, Antje; Tilden, Dominic

    2013-11-01

    The need for ongoing and lifelong follow-up (FU) of patients with cardiac implantable electric devices (CIED) requires significant resources. Remote CIED management has been established as a safe alternative to conventional periodical in-office FU (CFU). An economic model compares the long-term cost and consequences of using daily Home Monitoring® (HM) instead of CFU. A cost-consequence evaluation comparing HM vs. CFU was performed using a Markov cohort model and data relating to events and costs identified via a systematic review of the literature. The model is conservative, without assuming a reduction of cardiovascular events by HM such as decompensated heart failure or mortality, or considering cost savings such as for transportation. Also cost savings due to an improved timing of elective device replacement, and fewer FU visits needed in patients near device replacement are not considered. Over 10 years, HM is predicted to be cost neutral at about GBP 11 500 per patient in either treatment arm, with all costs for the initial investment into HM and fees for ongoing remote monitoring included. Fewer inappropriate shocks (-51%) reduce the need for replacing devices for battery exhaustion (-7%); the number of FU visits is predicted to be halved by HM. From a UK National Health Service perspective, HM is cost neutral over 10 years. This is mainly accomplished by reducing the number of battery charges and inappropriate shocks, resulting in fewer device replacements, and by reducing the number of in-clinic FU visits.

  15. Overview of a Hybrid Underwater Camera System

    DTIC Science & Technology

    2014-07-01

    meters), in increments of 200ps. The camera is also equipped with 6:1 motorized zoom lens. A precision miniature attitude, heading reference system ( AHRS ...LUCIE Control & Power Distribution System AHRS Pulsed LASER Gated Camera -^ Sonar Transducer (b) LUCIE sub-systems Proc. ofSPIEVol. 9111

  16. 3DFATMIC: THREE DIMENSIONAL SUBSURFACE FLOW, FATE AND TRANSPORT OF MICROBES AND CHEMICALS MODEL - USER'S MANUAL VERSION 1.0

    EPA Science Inventory

    This document is the user's manual of 3DFATMIC, a 3-Dimensional Subsurface Flow, Fate and Transport of Microbes and Chemicals Model using a Lagrangian-Eulerian adapted zooming and peak capturing (LEZOOMPC) algorithm.

  17. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study.

    PubMed

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients.

  18. Design of two-DMD based zoom MW and LW dual-band IRSP using pixel fusion

    NASA Astrophysics Data System (ADS)

    Pan, Yue; Xu, Xiping; Qiao, Yang

    2018-06-01

    In order to test the anti-jamming ability of mid-wave infrared (MWIR) and long-wave infrared (LWIR) dual-band imaging system, a zoom mid-wave (MW) and long-wave (LW) dual-band infrared scene projector (IRSP) based on two-digital micro-mirror device (DMD) was designed by using a projection method of pixel fusion. Two illumination systems, which illuminate the two DMDs directly with Kohler telecentric beam respectively, were combined with projection system by a spatial layout way. The distances of projection entrance pupil and illumination exit pupil were also analyzed separately. MWIR and LWIR virtual scenes were generated respectively by two DMDs and fused by a dichroic beam combiner (DBC), resulting in two radiation distributions in projected image. The optical performance of each component was evaluated by ray tracing simulations. Apparent temperature and image contrast were demonstrated by imaging experiments. On the basis of test and simulation results, the aberrations of optical system were well corrected, and the quality of projected image meets test requirements.

  19. Zooming in on cirrus with the Canadian Regional Climate Model

    NASA Astrophysics Data System (ADS)

    Stefanof, C.; Stefanof, A.; Beaulne, A.; Munoz Alpizar, R.; Szyrmer, W.; Blanchet, J.

    2004-05-01

    The Canadian Regional Climate Model plus a microphysical scheme: two-moments microphysics with three hydrometeor categories (cloud liquid water, pristine ice crystals and larger precipitation crystals) is used to test the simulation in forecast mode using ECMWF data at 0.4 X 0.4 degree. We are zooming in on cirrus at higher resolutions (9, 1.8, 0.36 km). We are currently using the data set measured in APEX-E3, measurements of radar, lidar, passive instruments and interpreted microphysics for some flights (G-II, C404, B200). The radar and lidar data are available for high level cirrus. The south west of Japon is the flight region. The dates are March 20, March 27 and April 2, 2003. We first focus on the March 27 frontal system. We did a rigorous synoptical analysis for the cases. The cirrus at 360 m resolution are simulated. The cloud structure and some similarities between model simulation and observations will be presented.

  20. Automated exterior inspection of an aircraft with a pan-tilt-zoom camera mounted on a mobile robot

    NASA Astrophysics Data System (ADS)

    Jovančević, Igor; Larnier, Stanislas; Orteu, Jean-José; Sentenac, Thierry

    2015-11-01

    This paper deals with an automated preflight aircraft inspection using a pan-tilt-zoom camera mounted on a mobile robot moving autonomously around the aircraft. The general topic is image processing framework for detection and exterior inspection of different types of items, such as closed or unlatched door, mechanical defect on the engine, the integrity of the empennage, or damage caused by impacts or cracks. The detection step allows to focus on the regions of interest and point the camera toward the item to be checked. It is based on the detection of regular shapes, such as rounded corner rectangles, circles, and ellipses. The inspection task relies on clues, such as uniformity of isolated image regions, convexity of segmented shapes, and periodicity of the image intensity signal. The approach is applied to the inspection of four items of Airbus A320: oxygen bay handle, air-inlet vent, static ports, and fan blades. The results are promising and demonstrate the feasibility of an automated exterior inspection.

  1. Polydimethylsiloxane as dielectric and hydrophobic material in electro-wetting liquid lens

    NASA Astrophysics Data System (ADS)

    Wang, Liang; Duan, Junping; Zhang, Binzhen; Wang, Wanjun

    2016-10-01

    An electro-wetting-based variable-focus liquid lens with a spin coated polydimethylsiloxane (PDMS) layer is presented. The PDMS layer acts as both insulation and hydrophobic material of the liquid lens. By changing the applied voltage between the two electrodes, the radius of the water-oil contact curved surface is adjusted to realize the zoom function. In preparation process, at first, the liquid lens is divided into two parts, the PDMS substrate and the cavity, and then two parts of liquid lens are bonding together after surface treatment. After liquid injection and sealing cavity, the whole process was accomplished. The zooming performance of lens is tested, and COMSOL is used to analyze the shape of the water-oil contact curved surface at different voltages, the results shows that with the applied voltage changing from 0V to 120V, the height of meniscus vertex reduced from 2.41mm to 1.67mm, and the focal length changes from -14.3mm to infinity first, and then to 27.1mm.

  2. Usage of Accessibility Options for the iPhone and iPad in a Visually Impaired Population.

    PubMed

    Robinson, Joshua L; Braimah Avery, Vanessa; Chun, Rob; Pusateri, Gregg; Jay, Walter M

    2017-01-01

    The iPad and iPhone have a number of low-vision accessibility features including Siri Voice Assistant, Large Text, Zoom Magnification, Invert Colors, Voice Over, and Speech Selection. We studied their usage within a low-vision population. Patients were recruited to participate in an IRB-approved survey regarding their usage of the iPad and/or iPhone. Participants met one of the following criteria: best corrected visual acuity (BCVA) of 20/60 or worse, or significant peripheral visual field defects. Thirty-three low-vision patients agreed to participate (mean age 54.3 years). There were 18 different diagnoses represented and the average visual acuity of respondents was 20/119 in the right eye and 20/133 in the left eye. The most commonly used vision accessibility features were Zoom Magnification and Large Text. Although many patients are using the low-vision accessibility features, few are receiving training or recommendations from their eye care specialist.

  3. Fundamental Fractal Antenna Design Process

    NASA Astrophysics Data System (ADS)

    Zhu, L. P.; Kim, T. C.; Kakas, G. D.

    2017-12-01

    Antenna designers are always looking to come up with new ideas to push the envelope for new antennas, using a smaller volume while striving for higher bandwidth, wider bandwidth, and antenna gain. One proposed method of increasing bandwidth or shrinking antenna size is via the use of fractal geometry, which gives rise to fractal antennas. Fractals are those fun shapes that if one zooms in or zoom out, the structure is always the same. Design a new type of antenna based on fractal antenna design by utilize the Design of Experiment (DOE) will be shown in fractal antenna design process. Investigate conformal fractal antenna design for patterns, dimensions, and size, of the antenna but maintaining or improving the antenna performance. Research shows an antenna designer how to create basic requirements of the fractal antenna through a step by step process, and provides how to optimize the antenna design with the model prediction, lab measurement, and actual results from the compact range measurement on the antenna patterns.

  4. Zoom-in on Epimetheus

    NASA Image and Video Library

    2017-07-03

    This zoomed-in view of Epimetheus, one of the highest resolution ever taken, shows a surface covered in craters, vivid reminders of the hazards of space. Epimetheus (70 miles or 113 kilometers across) is too small for its gravity to hold onto an atmosphere. It is also too small to be geologically active. There is therefore no way to erase the scars from meteor impacts, except for the generation of new impact craters on top of old ones. This view looks toward anti-Saturn side of Epimetheus. North on Epimetheus is up and rotated 32 degrees to the right. The image was taken with the Cassini spacecraft narrow-angle camera on Feb. 21, 2017 using a spectral filter which preferentially admits wavelengths of near-infrared light centered at 939 nanometers. The view was acquired at a distance of approximately 9,300 miles (15,000 kilometers) from Epimetheus and at a Sun-Epimetheus-spacecraft, or phase, angle of 71 degrees. Image scale is 290 feet (89 meters) per pixel. https://photojournal.jpl.nasa.gov/catalog/PIA21335

  5. Approaching neuropsychological tasks through adaptive neurorobots

    NASA Astrophysics Data System (ADS)

    Gigliotta, Onofrio; Bartolomeo, Paolo; Miglino, Orazio

    2015-04-01

    Neuropsychological phenomena have been modelized mainly, by the mainstream approach, by attempting to reproduce their neural substrate whereas sensory-motor contingencies have attracted less attention. In this work, we introduce a simulator based on the evolutionary robotics platform Evorobot* in order to setting up in silico neuropsychological tasks. Moreover, in this study we trained artificial embodied neurorobotic agents equipped with a pan/tilt camera, provided with different neural and motor capabilities, to solve a well-known neuropsychological test: the cancellation task in which an individual is asked to cancel target stimuli surrounded by distractors. Results showed that embodied agents provided with additional motor capabilities (a zooming/attentional actuator) outperformed simple pan/tilt agents, even those equipped with more complex neural controllers and that the zooming ability is exploited to correctly categorising presented stimuli. We conclude that since the sole neural computational power cannot explain the (artificial) cognition which emerged throughout the adaptive process, such kind of modelling approach can be fruitful in neuropsychological modelling where the importance of having a body is often neglected.

  6. A Fractured Pole

    NASA Image and Video Library

    2015-10-15

    NASA's Cassini spacecraft zoomed by Saturn's icy moon Enceladus on Oct. 14, 2015, capturing this stunning image of the moon's north pole. A companion view from the wide-angle camera (PIA20010) shows a zoomed out view of the same region for context. Scientists expected the north polar region of Enceladus to be heavily cratered, based on low-resolution images from the Voyager mission, but high-resolution Cassini images show a landscape of stark contrasts. Thin cracks cross over the pole -- the northernmost extent of a global system of such fractures. Before this Cassini flyby, scientists did not know if the fractures extended so far north on Enceladus. North on Enceladus is up. The image was taken in visible green light with the Cassini spacecraft narrow-angle camera. The view was acquired at a distance of approximately 4,000 miles (6,000 kilometers) from Enceladus and at a Sun-Enceladus-spacecraft, or phase, angle of 9 degrees. Image scale is 115 feet (35 meters) per pixel. http://photojournal.jpl.nasa.gov/catalog/PIA19660

  7. Virtual finger boosts three-dimensional imaging and microsurgery as well as terabyte volume image visualization and analysis.

    PubMed

    Peng, Hanchuan; Tang, Jianyong; Xiao, Hang; Bria, Alessandro; Zhou, Jianlong; Butler, Victoria; Zhou, Zhi; Gonzalez-Bellido, Paloma T; Oh, Seung W; Chen, Jichao; Mitra, Ananya; Tsien, Richard W; Zeng, Hongkui; Ascoli, Giorgio A; Iannello, Giulio; Hawrylycz, Michael; Myers, Eugene; Long, Fuhui

    2014-07-11

    Three-dimensional (3D) bioimaging, visualization and data analysis are in strong need of powerful 3D exploration techniques. We develop virtual finger (VF) to generate 3D curves, points and regions-of-interest in the 3D space of a volumetric image with a single finger operation, such as a computer mouse stroke, or click or zoom from the 2D-projection plane of an image as visualized with a computer. VF provides efficient methods for acquisition, visualization and analysis of 3D images for roundworm, fruitfly, dragonfly, mouse, rat and human. Specifically, VF enables instant 3D optical zoom-in imaging, 3D free-form optical microsurgery, and 3D visualization and annotation of terabytes of whole-brain image volumes. VF also leads to orders of magnitude better efficiency of automated 3D reconstruction of neurons and similar biostructures over our previous systems. We use VF to generate from images of 1,107 Drosophila GAL4 lines a projectome of a Drosophila brain.

  8. Improvements on high-precision measurement of bromine isotope ratios by multicollector inductively coupled plasma mass spectrometry.

    PubMed

    Wei, Hai-Zhen; Jiang, Shao-Yong; Zhu, Zhi-Yong; Yang, Tao; Yang, Jing-Hong; Yan, Xiong; Wu, He-Pin; Yang, Tang-Li

    2015-10-01

    A new, feasible procedure for high-precision bromine isotope analysis using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is described. With a combination of HR mass resolution mode and accurate optimization of the Zoom Optics parameters (Focus Quad: -1.30; Zoom Quad: 0.00), the challenging problem of the isobaric interferences ((40)Ar(38)ArH(+) and (40)Ar(40)ArH(+)) in the measurement of bromine isotopes ((79)Br(+), (81)Br(+)) has been effectively solved. The external reproducibility of the measured (81)Br/(79)Br ratios in the selected standard reference materials ranged from ±0.03‰ to ±0.14‰, which is superior to or equivalent to the best results from previous contributions. The effect of counter cations on the Br(+) signal intensity and the instrumental-induced mass bias was evaluated as the loss of HBr aerosol in nebulizer and potential diffusive isotope fractionations. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Numerical Propulsion System Simulation Architecture

    NASA Technical Reports Server (NTRS)

    Naiman, Cynthia G.

    2004-01-01

    The Numerical Propulsion System Simulation (NPSS) is a framework for performing analysis of complex systems. Because the NPSS was developed using the object-oriented paradigm, the resulting architecture is an extensible and flexible framework that is currently being used by a diverse set of participants in government, academia, and the aerospace industry. NPSS is being used by over 15 different institutions to support rockets, hypersonics, power and propulsion, fuel cells, ground based power, and aerospace. Full system-level simulations as well as subsystems may be modeled using NPSS. The NPSS architecture enables the coupling of analyses at various levels of detail, which is called numerical zooming. The middleware used to enable zooming and distributed simulations is the Common Object Request Broker Architecture (CORBA). The NPSS Developer's Kit offers tools for the developer to generate CORBA-based components and wrap codes. The Developer's Kit enables distributed multi-fidelity and multi-discipline simulations, preserves proprietary and legacy codes, and facilitates addition of customized codes. The platforms supported are PC, Linux, HP, Sun, and SGI.

  10. Visualizing Soil Landscapes on Mobile Devices

    NASA Astrophysics Data System (ADS)

    Schulze, Darrell; Lindbo, David

    2016-04-01

    The Integrating Spatial Educational Experiences (Isee) project utilizes the most detailed US soil survey data to create thematic maps of soil properties that are then combined with a highly optimized hillshade basemap for display. The Isee app, currently available for the iPad platform from the Apple App Store, allows the cached maps to be zoomed and panned quickly to any location down to a scale of 1:18,000. Maps currently available for the states of Indiana, Illinois, Kentucky, Ohio, Texas, West Virginia, and Wisconsin include, Dominant Soil Parent Materials, Natural Soil Drainage Classes, Limiting Layers, Surface Soil Colors, and Acid Subsoils. Other thematic maps will be added in the future. The ability to zoom, pan, and change maps quickly allows the user to see and understand soil landscape relationships that are not often apparent using static maps, while the ability to access the maps conveniently in the field allows the user to see how soil landscape features on the maps appear in the field.

  11. VPython: Writing Real-time 3D Physics Programs

    NASA Astrophysics Data System (ADS)

    Chabay, Ruth

    2001-06-01

    VPython (http://cil.andrew.cmu.edu/projects/visual) combines the Python programming language with an innovative 3D graphics module called Visual, developed by David Scherer. Designed to make 3D physics simulations accessible to novice programmers, VPython allows the programmer to write a purely computational program without any graphics code, and produces an interactive realtime 3D graphical display. In a program 3D objects are created and their positions modified by computational algorithms. Running in a separate thread, the Visual module monitors the positions of these objects and renders them many times per second. Using the mouse, one can zoom and rotate to navigate through the scene. After one hour of instruction, students in an introductory physics course at Carnegie Mellon University, including those who have never programmed before, write programs in VPython to model the behavior of physical systems and to visualize fields in 3D. The Numeric array processing module allows the construction of more sophisticated simulations and models as well. VPython is free and open source. The Visual module is based on OpenGL, and runs on Windows, Linux, and Macintosh.

  12. Omniview motionless camera orientation system

    NASA Technical Reports Server (NTRS)

    Zimmermann, Steven D. (Inventor); Martin, H. Lee (Inventor)

    1999-01-01

    A device for omnidirectional image viewing providing pan-and-tilt orientation, rotation, and magnification within a hemispherical field-of-view that utilizes no moving parts. The imaging device is based on the effect that the image from a fisheye lens, which produces a circular image of at entire hemispherical field-of-view, which can be mathematically corrected using high speed electronic circuitry. More specifically, an incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical field-of-view without the need for any mechanical mechanisms. The preferred embodiment of the image transformation device can provide corrected images at real-time rates, compatible with standard video equipment. The device can be used for any application where a conventional pan-and-tilt or orientation mechanism might be considered including inspection, monitoring, surveillance, and target acquisition.

  13. Virtual Vision

    NASA Astrophysics Data System (ADS)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  14. X-window-based 2K display workstation

    NASA Astrophysics Data System (ADS)

    Weinberg, Wolfram S.; Hayrapetian, Alek S.; Cho, Paul S.; Valentino, Daniel J.; Taira, Ricky K.; Huang, H. K.

    1991-07-01

    A high-definition, high-performance display station for reading and review of digital radiological images is introduced. The station is based on a Sun SPARC Station 4 and employs X window system for display and manipulation of images. A mouse-operated graphic user interface is implemented utilizing Motif-style tools. The system supports up to four MegaScan gray-scale 2560 X 2048 monitors. A special configuration of frame and video buffer yields a data transfer of 50 M pixels/s. A magnetic disk array supplies a storage capacity of 2 GB with a data transfer rate of 4-6 MB/s. The system has access to the central archive through an ultrahigh-speed fiber-optic network and patient studies are automatically transferred to the local disk. The available image processing functions include change of lookup table, zoom and pan, and cine. Future enhancements will provide for manual contour tracing, length, area, and density measurements, text and graphic overlay, as well as composition of selected images. Additional preprocessing procedures under development will optimize the initial lookup table and adjust the images to a standard orientation.

  15. Camera Control and Geo-Registration for Video Sensor Networks

    NASA Astrophysics Data System (ADS)

    Davis, James W.

    With the use of large video networks, there is a need to coordinate and interpret the video imagery for decision support systems with the goal of reducing the cognitive and perceptual overload of human operators. We present computer vision strategies that enable efficient control and management of cameras to effectively monitor wide-coverage areas, and examine the framework within an actual multi-camera outdoor urban video surveillance network. First, we construct a robust and precise camera control model for commercial pan-tilt-zoom (PTZ) video cameras. In addition to providing a complete functional control mapping for PTZ repositioning, the model can be used to generate wide-view spherical panoramic viewspaces for the cameras. Using the individual camera control models, we next individually map the spherical panoramic viewspace of each camera to a large aerial orthophotograph of the scene. The result provides a unified geo-referenced map representation to permit automatic (and manual) video control and exploitation of cameras in a coordinated manner. The combined framework provides new capabilities for video sensor networks that are of significance and benefit to the broad surveillance/security community.

  16. WEBGIS based CropWatch online agriculture monitoring system

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Wu, B.; Zeng, H.; Zhang, M.; Yan, N.

    2015-12-01

    CropWatch, which was developed by the Institute of Remote Sensing and Digital Earth (RADI), Chinese Academy of Sciences (CAS), has achieved breakthrough results in the integration of methods, independence of the assessments and support to emergency response by periodically releasing global agricultural information. Taking advantages of the multi-source remote sensing data and the openness of the data sharing policies, CropWatch group reported their monitoring results by publishing four bulletins one year. In order to better analysis and generate the bulletin and provide an alternative way to access agricultural monitoring indicators and results in CropWatch, The CropWatch online system based on the WEBGIS techniques has been developed. Figure 1 shows the CropWatch online system structure and the system UI in Clustering mode. Data visualization is sorted into three different modes: Vector mode, Raster mode and Clustering mode. Vector mode provides the statistic value for all the indicators over each monitoring units which allows users to compare current situation with historical values (average, maximum, etc.). Users can compare the profiles of each indicator over the current growing season with the historical data in a chart by selecting the region of interest (ROI). Raster mode provides pixel based anomaly of CropWatch indicators globally. In this mode, users are able to zoom in to the regions where the notable anomaly was identified from statistic values in vector mode. Data from remote sensing image series at high temporal and low spatial resolution provide key information in agriculture monitoring. Clustering mode provides integrated information on different classes in maps, the corresponding profiles for each class and the percentage of area of each class to the total area of all classes. The time series data is categorized into limited types by the ISODATA algorithm. For each clustering type, pixels on the map, profiles, and percentage legend are all linked together. All the three visualization methods are applied to four scales including 65 monitoring and reporting units (MRUs), 7 major production zones (MPZs), 173 countries and sub-countries for 9 large countries. Agro-Climatic information, Agronomic information and indicators related with crop area, crop yield and crop production are provided.

  17. A Structural Health Monitoring Workshop Roadmap for Transitioning Critical Technology from Research to Practice

    DTIC Science & Technology

    2012-01-24

    Kersey et. al., 1997). There are other types of fiber optic sensors that can be multiplexed such as extrinsic Fabry -Perot interferometers (EFPI), but...census bureau, and outbreak monitoring by the US Centers for Disease Control (CDC). • One approach to data management is replacing conventional

  18. Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.

    PubMed

    Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H

    2018-02-01

    The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Visual Arts Research, 1994.

    ERIC Educational Resources Information Center

    Gardner, Nancy C., Ed.; Thompson, Christine, Ed.

    1994-01-01

    This document consists of the two issues of the journal "Visual Arts in Research" published in 1994. This journal focuses on the theory and practice of visual arts education from educational, historical, philosophical, and psychological perspectives. Number 1 of this volume includes the following contributions: (1) "Zooming in on the Qualitative…

  20. Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems

    EPA Science Inventory

    The purpose of the field demonstration program is to gather technically reliable cost and performance information on selected condition assessment technologies under defined field conditions. The selected technologies include zoom camera, electro-scan (FELL-41), and a multi-sens...

  1. Monitoring of the Atmosphere on the International Space Station with the Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    Wallace William T.; Limero, Thomas F.; Loh, Leslie J.; Mudgett, Paul D.; Gazda, Daniel B.

    2017-01-01

    During the early years of human spaceflight, short duration missions allowed for monitoring of the spacecraft environment to be performed via archival sampling, in which samples were returned to Earth for analysis. With the construction of the International Space Station (ISS) and the accompanying extended mission durations, the need for enhanced, real-time monitors became apparent. The Volatile Organic Analyzer (VOA) operated on ISS for 7 years, where it assessed trace volatile organic compounds in the cabin air. The large and fixed-position VOA was eventually replaced with the smaller Air Quality Monitor (AQM). Since March 2013, the atmosphere of the U.S. Operating Segment (USOS) has been monitored in near real-time by a pair of AQMs. These devices consist of a gas chromatograph (GC) coupled with a differential mobility spectrometer (DMS) and currently target detection list of 22 compounds. These targets are of importance to both crew health and the Environmental Control and Life Support Systems (ECLSS) on ISS. Data is collected autonomously every 73 hours, though the units can be controlled remotely from mission control to collect data more frequently during contingency or troubleshooting operations. Due to a nominal three-year lifetime on-orbit, the initial units were replaced in February 2016. This paper will focus on the preparation and use of the AQMs over the past several years. A description of the technical aspects of the AQM will be followed by lessons learned from the deployment and operation of the first set of AQMs. These lessons were used to improve the already-excellent performance of the instruments prior to deployment of the replacement units. Data trending over the past several years of operation on ISS will also be discussed, including data obtained during a survey of the USOS modules. Finally, a description of AQM use for contingency and investigative studies will be presented.

  2. Kinetics of methane hydrate replacement with carbon dioxide and nitrogen gas mixture using in situ NMR spectroscopy.

    PubMed

    Cha, Minjun; Shin, Kyuchul; Lee, Huen; Moudrakovski, Igor L; Ripmeester, John A; Seo, Yutaek

    2015-02-03

    In this study, the kinetics of methane replacement with carbon dioxide and nitrogen gas in methane gas hydrate prepared in porous silica gel matrices has been studied by in situ (1)H and (13)C NMR spectroscopy. The replacement process was monitored by in situ (1)H NMR spectra, where about 42 mol % of the methane in the hydrate cages was replaced in 65 h. Large amounts of free water were not observed during the replacement process, indicating a spontaneous replacement reaction upon exposing methane hydrate to carbon dioxide and nitrogen gas mixture. From in situ (13)C NMR spectra, we confirmed that the replacement ratio was slightly higher in small cages, but due to the composition of structure I hydrate, the amount of methane evolved from the large cages was larger than that of the small cages. Compositional analysis of vapor and hydrate phases was also carried out after the replacement reaction ceased. Notably, the composition changes in hydrate phases after the replacement reaction would be affected by the difference in the chemical potential between the vapor phase and hydrate surface rather than a pore size effect. These results suggest that the replacement technique provides methane recovery as well as stabilization of the resulting carbon dioxide hydrate phase without melting.

  3. Next Generation of Air Quality Measurements from Geo Orbits: Breaking The Temporal Barrier

    NASA Astrophysics Data System (ADS)

    Gupta, P.; Levy, R. C.; Mattoo, S.; Remer, L.; Heidinger, A.

    2017-12-01

    NASA's dark target (DT) aerosol algorithm provides operational retrieval of atmospheric aerosols from multiple polar orbiting satellites. The DT algorithm, initially developed for MODIS observations, has been continuously improved since the first MODIS launch in early 2000. Now, we are adapting the DT algorithm to retrieve on new-generation geostationary (GEO) sensors, including the Advanced Himawari Imager (AHI) on Japan's Himawari-8 (H8) satellite and Advanced Baseline Imager (ABI) on NOAA's GOES-16 (or GOES-R). H8 is a weather geostationary satellite operating since July 2015, and AHI observes earth-atmosphere system over the Asia-Pacific region at spatial resolutions of 1km or less. GOES-R is launched in Nov 2016 and provides high temporal resolution observations over Americas. With 16 spectral channels, including 7 bands that observe similar wavelengths as the MODIS bands used for DT aerosol retrieval. Most exciting, however, is that both ABI and AHI provides full disk observations every 10-15 minutes and zoom mode observations every 30 second to 2.5 minutes. Therefore, spectral, spatial and temporal resolution observations from these GEO satellites provide opportunity to monitor atmospheric aerosols in the region, plus a new capability to monitor aerosol transport and aerosol/cloud diurnal cycles. In this paper, we will introduce retrieval results from AHI using the DT algorithm during the KORUS-AQ field campaign during summer 2016. These results are evaluated against surface measurements (e.g. AERONET). . We will also discuss, its potential applications in monitoring diurnal cycles of urban pollution, smoke and dust in the region. The same DT algorithm will also be adapted to retrieve aerosol properties using GOES-16 over Americas.

  4. Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM).

    PubMed

    Biau, D J; Meziane, M; Bhumbra, R S; Dumaine, V; Babinet, A; Anract, P

    2011-09-01

    The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.

  5. [A project to provide instruction in the nursing of elderly patients with total hip replacement (T.H.R.)].

    PubMed

    Ting, Chao-Fong; Chou, Hsiu-Ling; Chen, Ming-Mie

    2006-02-01

    This project was aimed at improving the nursing of patients who have undergone total hip replacements. Investigation showed the following problems with existing nursing instruction in this area: lack of standard instruction, outdated educational materials, a 33.75% rate of completion of instruction lack of familiarity with instruction materials, and an average satisfaction score of 2.56 among nurses who have undergone instruction; The reading for patient's satisfaction with the guidance of nurses was 2.04. After site investigation, status analysis and reference check, we proposed the following program. (1) Establish standards and monitor tools for instruction for nursing total hip replacement patients, including "Caring standard", "Guidance for nursing instruction", "Nursing instruction sheet", "Notes at nursing instruction", "Satisfaction scoring system for nursing instruction"; (2) Carry out a training course to enhance nursing staff's knowledge about caring for patients with total hip replacement. After program had been implemented, a completion rate of 88.56% was achieved, and the satisfaction scores among nursing staff and patients were 4.3 and 4.36 respectively. This result shows that when we undertake reform at various different levels--including systemic structure, processing and monitoring--this can radically improve the quality of nursing instruction.

  6. Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units

    NASA Astrophysics Data System (ADS)

    Wilson, Brooke E.; Meneghini, Michael; Anton, Steven R.

    2015-04-01

    The knee replacement is the second most common orthopedic surgical intervention in the United States, but currently only 1 in 5 knee replacement patients are satisfied with their level of pain reduction one year after surgery. It is imperative to make the process of knee replacement surgery more objective by developing a data driven approach to ligamentous balance, which increases implant life. In this work, piezoelectric materials are considered for both sensing and energy harvesting applications in total knee replacement implants. This work aims to embed piezoelectric material in the polyethylene bearing of a knee replacement unit to act as self-powered sensors that will aid in the alignment and balance of the knee replacement by providing intraoperative feedback to the surgeon. Postoperatively, the piezoelectric sensors can monitor the structural health of the implant in order to perceive potential problems before they become bothersome to the patient. Specifically, this work will present on the use of finite element modeling coupled with uniaxial compression testing to prove that piezoelectric stacks can be utilized to harvest sufficient energy to power sensors needed for this application.

  7. A Summary of the Third Persh Conference: Strategic Issues in Materials for National Defense

    DTIC Science & Technology

    2012-12-01

    addresses a distinct materials-related topic of strategic importance, ranging from thermal management materials to data mining, and from...such as aerogels, shape-memory alloys, polymers, electronic ink, and zeolites . The second demonstration kit, “Zoom in on Life,” investigates how the

  8. 77 FR 28391 - Announcement of Requirements and Registration for “Ocular Imaging Challenge”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ..., color, zoom, pan) Integrate with existing EHRs (e.g. ``single sign-on'') Where applicable, leverage and... existing office hardware platforms, and to integrate with existing EHR systems (e.g. ``single sign-on... on the acquisition devices in proprietary databases and file formats, and therefore have limited...

  9. Next Generation Clustered Heat Maps | Informatics Technology for Cancer Research (ITCR)

    Cancer.gov

    Next-Generation (Clustered) Heat Maps are interactive heat maps that enable the user to zoom and pan across the heatmap, alter its color scheme, generate production quality PDFs, and link out from rows, columns, and individual heatmap entries to related statistics, databases and other information.

  10. Elaboration: The Power Punch of "Body Language" Detail

    ERIC Educational Resources Information Center

    Berger, Joan

    2003-01-01

    "Zooming in" with a camera lens led students in Joan Berger's class to enrich their writing exponentially. Through class discussion of body language, along with the use of worksheets (provided), role-playing, modeling, and conferencing, one aspect of lively writing became a part of their writing repertoire. (Contains 5 figures.)

  11. Petition for an Additional Vision Developmental Milestone

    ERIC Educational Resources Information Center

    Del Frari, Paul

    2012-01-01

    This petition is about two of the traditional three R's - reading, writing, and arithmetic; it concerns learning letter formation and learning to read, both of which require continuous interplay between the different perceptual attunements of central and paracentral areas of the retina. This interplay, managing the field of view between zooming-in…

  12. Zooming in on Children's Thinking

    ERIC Educational Resources Information Center

    Tucker, Steven; Shumway, Jessica F.; Moyer-Packenham, Patricia S.; Jordan, Kerry E.

    2016-01-01

    Teachers increasingly use virtual manipulatives and other apps on touch-screen devices (e.g., "iPads") in an effort to help students understand mathematics concepts. However, students experience these apps and their affordances in different ways. The purpose of this article is to inform teachers' decisions about app implementation in the…

  13. What Are We Saying? A Glossary of Communication & Technology Terms in the Learning Environment.

    ERIC Educational Resources Information Center

    Lavi, Art

    1993-01-01

    Defining terminologies accurately is a necessity in the learning environment. A glossary of related terms, developed by an instructor in a teacher training college is provided. "Applied" rather than "philosophic" definitions are determined. Terms are presented alphabetically, from "Advertising" to "Zoom Ratio." (AEF)

  14. Challenge '89: Interfacing of Chemical Instruments to Computers.

    ERIC Educational Resources Information Center

    Lyons, Jim; Lamarre, Colin

    This project involved interfacing of microcomputers with three chemical instruments--Nuclear Magnetic Resonance (NMR), Infrared Spectroscopy (IR), and the spectrophotometer. A Pascal program called "Spectrum" allows data from the NMR to be read and graphed, a specific area of the graph zoomed, ratios of specified areas of the graph…

  15. Avoiding treatment bias of REDD+ monitoring by sampling with partial replacement

    Treesearch

    Michael Kohl; Charles T Scott; Andrew J Lister; Inez Demon; Daniel Plugge

    2015-01-01

    Implementing REDD+ renders the development of a measurement, reporting and verification (MRV) system necessary to monitor carbon stock changes. MRV systems generally apply a combination of remote sensing techniques and in-situ field assessments. In-situ assessments can be based on 1) permanent plots, which are assessed on all successive occasions, 2) temporary plots,...

  16. Remote down-hole well telemetry

    DOEpatents

    Briles, Scott D [Los Alamos, NM; Neagley, Daniel L [Albuquerque, NM; Coates, Don M [Santa Fe, NM; Freund, Samuel M [Los Alamos, NM

    2004-07-20

    The present invention includes an apparatus and method for telemetry communication with oil-well monitoring and recording instruments located in the vicinity of the bottom of gas or oil recovery pipes. Such instruments are currently monitored using electrical cabling that is inserted into the pipes; cabling has a short life in this environment, and requires periodic replacement with the concomitant, costly shutdown of the well. Modulated reflectance, a wireless communication method that does not require signal transmission power from the telemetry package will provide a long-lived and reliable way to monitor down-hole conditions. Normal wireless technology is not practical since batteries and capacitors have to frequently be replaced or recharged, again with the well being removed from service. RF energy generated above ground can also be received, converted and stored down-hole without the use of wires, for actuating down-hole valves, as one example. Although modulated reflectance reduces or eliminates the loss of energy at the sensor package because energy is not consumed, during the transmission process, additional stored extra energy down-hole is needed.

  17. Conference on asbestos control and replacement for electric utilities: Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    An EPRI conference on Asbestos Control and Replacement for Electric Utilities was held April 9, 1992 in conjunction with the National Asbestos Council's Environmental Management 192 Conference and Exposition. The high cost and potential liabilities of asbestos removal projects, compounded by concerns over the health effects of asbestos replacement materials, was the main motivation for the conference. The objective of the conference was to assemble guidance and information that will help utilities manage asbestos and to effectively prioritize EPRI research in this area. Ten papers covered such topics as computer-aided asbestos management, utility experience with asbestos management, asbestos monitoring andmore » disposal, and asbestos replacement materials. Utility feedback received at the conference indicates that present and planned EPRI research activities in this area will effectively meet industry needs.« less

  18. NPOESS, Essential Climates Variables and Climate Change

    NASA Astrophysics Data System (ADS)

    Forsythe-Newell, S. P.; Bates, J. J.; Barkstrom, B. R.; Privette, J. L.; Kearns, E. J.

    2008-12-01

    Advancement in understanding, predicting and mitigating against climate change implies collaboration, close monitoring of Essential Climate Variable (ECV)s through development of Climate Data Record (CDR)s and effective action with specific thematic focus on human and environmental impacts. Towards this end, NCDC's Scientific Data Stewardship (SDS) Program Office developed Climate Long-term Information and Observation system (CLIO) for satellite data identification, characterization and use interrogation. This "proof-of-concept" online tool provides the ability to visualize global CDR information gaps and overlaps with options to temporally zoom-in from satellite instruments to climate products, data sets, data set versions and files. CLIO provides an intuitive one-stop web site that displays past, current and planned launches of environmental satellites in conjunction with associated imagery and detailed information. This tool is also capable of accepting and displaying Web-based input from Subject Matter Expert (SME)s providing a global to sub-regional scale perspective of all ECV's and their impacts upon climate studies. SME's can access and interact with temporal data from the past and present, or for future planning of products, datasets/dataset versions, instruments, platforms and networks. CLIO offers quantifiable prioritization of ECV/CDR impacts that effectively deal with climate change issues, their associated impacts upon climate, and this offers an intuitively objective collaboration and consensus building tool. NCDC's latest tool empowers decision makers and the scientific community to rapidly identify weaknesses and strengths in climate change monitoring strategies and significantly enhances climate change collaboration and awareness.

  19. QWIP technology for both military and civilian applications

    NASA Astrophysics Data System (ADS)

    Gunapala, Sarath D.; Kukkonen, Carl A.; Sirangelo, Mark N.; McQuiston, Barbara K.; Chehayeb, Riad; Kaufmann, M.

    2001-10-01

    Advanced thermal imaging infrared cameras have been a cost effective and reliable method to obtain the temperature of objects. Quantum Well Infrared Photodetector (QWIP) based thermal imaging systems have advanced the state-of-the-art and are the most sensitive commercially available thermal systems. QWIP Technologies LLC, under exclusive agreement with Caltech University, is currently manufacturing the QWIP-ChipTM, a 320 X 256 element, bound-to-quasibound QWIP FPA. The camera performance falls within the long-wave IR band, spectrally peaked at 8.5 μm. The camera is equipped with a 32-bit floating-point digital signal processor combined with multi- tasking software, delivering a digital acquisition resolution of 12-bits using nominal power consumption of less than 50 Watts. With a variety of video interface options, remote control capability via an RS-232 connection, and an integrated control driver circuit to support motorized zoom and focus- compatible lenses, this camera design has excellent application in both the military and commercial sector. In the area of remote sensing, high-performance QWIP systems can be used for high-resolution, target recognition as part of a new system of airborne platforms (including UAVs). Such systems also have direct application in law enforcement, surveillance, industrial monitoring and road hazard detection systems. This presentation will cover the current performance of the commercial QWIP cameras, conceptual platform systems and advanced image processing for use in both military remote sensing and civilian applications currently being developed in road hazard monitoring.

  20. Cooperative multisensor system for real-time face detection and tracking in uncontrolled conditions

    NASA Astrophysics Data System (ADS)

    Marchesotti, Luca; Piva, Stefano; Turolla, Andrea; Minetti, Deborah; Regazzoni, Carlo S.

    2005-03-01

    The presented work describes an innovative architecture for multi-sensor distributed video surveillance applications. The aim of the system is to track moving objects in outdoor environments with a cooperative strategy exploiting two video cameras. The system also exhibits the capacity of focusing its attention on the faces of detected pedestrians collecting snapshot frames of face images, by segmenting and tracking them over time at different resolution. The system is designed to employ two video cameras in a cooperative client/server structure: the first camera monitors the entire area of interest and detects the moving objects using change detection techniques. The detected objects are tracked over time and their position is indicated on a map representing the monitored area. The objects" coordinates are sent to the server sensor in order to point its zooming optics towards the moving object. The second camera tracks the objects at high resolution. As well as the client camera, this sensor is calibrated and the position of the object detected on the image plane reference system is translated in its coordinates referred to the same area map. In the map common reference system, data fusion techniques are applied to achieve a more precise and robust estimation of the objects" track and to perform face detection and tracking. The work novelties and strength reside in the cooperative multi-sensor approach, in the high resolution long distance tracking and in the automatic collection of biometric data such as a person face clip for recognition purposes.

  1. Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial.

    PubMed

    Halimi, Franck; Clémenty, Jacques; Attuel, Patrick; Dessenne, Xavier; Amara, Walid

    2008-12-01

    The OEDIPE trial examined the safety and efficacy of an abbreviated hospitalization after implantation or replacement of dual-chamber pacemakers (PM) using a telecardiology-based ambulatory surveillance programme. Patients were randomly assigned to (i) an active group, discharged from the hospital 24 h after a first PM implant or 4-6 h after replacement, and followed for 4 weeks with Home-Monitoring (HM), or (ii) a control group followed for 4 weeks according to usual medical practices. The primary objective was to confirm that the proportion of patients who experienced one or more major adverse events (MAE) was not higher in the active than in the control group. The study included 379 patients. At least one treatment-related MAE was observed in 9.2% of patients (n = 17) assigned to the active group vs. 13.3% of patients (n = 26) in the control group (P = 0.21), a 4.1% absolute risk reduction (95% CI -2.2 to 10.4; P = 0.98). By study design, the mean hospitalization duration was 34% shorter in the active than in the control group (P < 0.001), and HM facilitated the early detection of technical issues and detectable clinical anomalies. Early discharge with HM after PM implantation or replacement was safe and facilitated the monitoring of patients in the month following the procedure.

  2. Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial

    PubMed Central

    Halimi, Franck; Clémenty, Jacques; Attuel, Patrick; Dessenne, Xavier; Amara, Walid

    2008-01-01

    Aims The ŒDIPE trial examined the safety and efficacy of an abbreviated hospitalization after implantation or replacement of dual-chamber pacemakers (PM) using a telecardiology-based ambulatory surveillance programme. Methods and results Patients were randomly assigned to (i) an active group, discharged from the hospital 24 h after a first PM implant or 4–6 h after replacement, and followed for 4 weeks with Home-Monitoring (HM), or (ii) a control group followed for 4 weeks according to usual medical practices. The primary objective was to confirm that the proportion of patients who experienced one or more major adverse events (MAE) was not higher in the active than in the control group. The study included 379 patients. At least one treatment-related MAE was observed in 9.2% of patients (n = 17) assigned to the active group vs. 13.3% of patients (n = 26) in the control group (P = 0.21), a 4.1% absolute risk reduction (95% CI −2.2 to 10.4; P = 0.98). By study design, the mean hospitalization duration was 34% shorter in the active than in the control group (P < 0.001), and HM facilitated the early detection of technical issues and detectable clinical anomalies. Conclusion Early discharge with HM after PM implantation or replacement was safe and facilitated the monitoring of patients in the month following the procedure. PMID:18775878

  3. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study

    PubMed Central

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    Objectives The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. Methods A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Results Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Conclusion Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients. PMID:27093294

  4. Finding of No Significant Impact: Replacement of Chemical Cleaning Line Tinker Air Force Base Oklahoma City, Oklahoma

    DTIC Science & Technology

    2012-05-01

    indoor air quality from installation of a new, improved cleaning line ventilation system. Cultural Resources No adverse effect on cultural...EA) has been prepared to assess the potential effects on the human and natural environment of replacing the chemical cleaning line at Tinker Air...providing improved system monitors and controls, reducing the overall energy consumption of the system, and enabling the system to accommodate larger

  5. Lower Methow tributaries intensive effectiveness monitoring study. Interim report

    USGS Publications Warehouse

    Martens, Kyle D.; Connolly, Patrick J.

    2008-01-01

    Actions have been taken to replace diversion dams in lower Beaver Creek with a series of rock vortex weirs. Some of these diversion dams have been in place for over 100 years, and they have impaired or completely blocked upstream migration of fish. Three diversion dams were replaced in 2003 (Lower Stokes, Thurlow Transfer, and Upper Stokes), and a forth diversion dam was replaced in 2004 (Fort-Thurlow). These vortex weirs were designed and installed under the supervision of U.S. Bureau of Reclamation (BOR) engineers and completed in accordance to National Marine Fisheries Service (NMFS) and Washington Department of Fisheries and Wildlife (WDFW) fish passage criteria. The projects were designed to meet fish species recovery needs described by the Endangered Species Act (ESA) and the “BiOp” issued by NMFS (2000a). Since no specific guidelines have been identified to date specifically addressing diversion dams, WDFW and NMFS guidelines are being considered as the target design and performance criteria for the sites monitored as part of this project. Where used, the vortex weirs were designed to maintain irrigation diversion capabilities while improving fish passage.

  6. Subcutaneous Implantable Cardioverter-Defibrillator

    MedlinePlus

    ... the SICD. The SICD lacks remote monitoring capabilities. Battery Life Device battery replacement is necessary for all patients with implanted devices. The SICD battery life is not as long as that of ...

  7. Orbit Transfer Rocket Engine Technology Program: Advanced engine study, task D.1/D.3

    NASA Technical Reports Server (NTRS)

    Martinez, A.; Erickson, C.; Hines, B.

    1986-01-01

    Concepts for space maintainability of OTV engines were examined. An engine design was developed which was driven by space maintenance requirements and by a failure mode and effects (FME) analysis. Modularity within the engine was shown to offer cost benefits and improved space maintenance capabilities. Space operable disconnects were conceptualized for both engine change-out and for module replacement. Through FME mitigation the modules were conceptualized to contain the least reliable and most often replaced engine components. A preliminary space maintenance plan was developed around a controls and condition monitoring system using advanced sensors, controls, and condition monitoring concepts. A complete engine layout was prepared satisfying current vehicle requirements and utilizing projected component advanced technologies. A technology plan for developing the required technology was assembled.

  8. UMCS feasibility study for Fort George G. Meade. Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-12-01

    Fort George G. Meade selected eighty-three (83) buildings, from the approximately 1,500 buildings on the base to be included in the UMCS Feasibility Study. The purpose of the study is to evaluate the feasibility of replacing the existing analog based Energy Monitoring and Control System (EMCS) with a new distributed process Monitoring and Control System (UMCS).

  9. UMCS feasibility study for Fort George G. Meade volume 1. Feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-12-01

    Fort George G. Meade selected 83 buildings, from the approximately 1,500 buildings on the base to be included in the UMCS Feasibility Study. The purpose of the study is to evaluate the feasibility of replacing the existing analog based Energy Monitoring and Control System (EMCS) with a new distributed process Monitoring and Control System (UMCS).

  10. View west of load dispatch model board; section covers substations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  11. 77 FR 5210 - Approval and Promulgation of Implementation Plans and Designations of Areas for Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-02

    .... SUMMARY: EPA is proposing to determine, pursuant to the Clean Air Act (CAA), that the bi-state St. Louis... replacement monitor be combined. Table 3--Design Values for Incomplete Data Monitors Compared to Highest... design values are used to compare against the NAAQS. Table 3 illustrates that the Arnold and Tenbrook and...

  12. Temperatures kept cool in Southampton.

    PubMed

    McDonald, Katey

    2010-03-01

    According to Digitron, hospitals countrywide are seeing the benefits of DigiTrak, the company's automatic wireless temperature monitoring system. Katey McDonald, the company's marketing manager, outlines how the system replaces traditional methods of data collection by providing a single networked package, and describes its use at Southampton General Hospital for blood monitoring, with the help of advanced biomedical scientist and quality officer there Marie Cundall.

  13. [Development of automatic urine monitoring system].

    PubMed

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  14. Robot Tracer with Visual Camera

    NASA Astrophysics Data System (ADS)

    Jabbar Lubis, Abdul; Dwi Lestari, Yuyun; Dafitri, Haida; Azanuddin

    2017-12-01

    Robot is a versatile tool that can function replace human work function. The robot is a device that can be reprogrammed according to user needs. The use of wireless networks for remote monitoring needs can be utilized to build a robot that can be monitored movement and can be monitored using blueprints and he can track the path chosen robot. This process is sent using a wireless network. For visual robot using high resolution cameras to facilitate the operator to control the robot and see the surrounding circumstances.

  15. Conceptualizing Magnification and Scale: The Roles of Spatial Visualization and Logical Thinking

    ERIC Educational Resources Information Center

    Jones, M. Gail; Gardner, Grant; Taylor, Amy R.; Wiebe, Eric; Forrester, Jennifer

    2011-01-01

    This study explored factors that contribute to students' concepts of magnification and scale. Spatial visualization, logical thinking, and concepts of magnification and scale were measured for 46 middle school students. Scores on the "Zoom Assessment" (an assessment of knowledge of magnification and scale) were correlated with the "Test of Logical…

  16. Changing Perspective: Zooming in and out during Visual Search

    ERIC Educational Resources Information Center

    Solman, Grayden J. F.; Cheyne, J. Allan; Smilek, Daniel

    2013-01-01

    Laboratory studies of visual search are generally conducted in contexts with a static observer vantage point, constrained by a fixation cross or a headrest. In contrast, in many naturalistic search settings, observers freely adjust their vantage point by physically moving through space. In two experiments, we evaluate behavior during free vantage…

  17. A Semantic Approach to Intelligent and Personal Tutoring System

    ERIC Educational Resources Information Center

    Sette, Maria

    2017-01-01

    Cyberlearning presents numerous challenges such as the lack of personal and assessment-driven learning, how students are often puzzled by the lack of instructor guidance and feedback, the huge volume of diverse learning materials, and the inability to zoom in from the general concepts to the more specific ones, or vice versa. Intelligent tutoring…

  18. II: The Bigger Picture

    ERIC Educational Resources Information Center

    Rosenfeld, Malke; Conarro, Ryan; Schwartz, Michael B.

    2014-01-01

    As seen in the previous section (EJ1039315) writing about teaching practice is more than simply reporting about what was done and in what order. When teachers zoom in closely to highlight the feel and tone of one particular classroom moment, lesson, or project, they create a microcosm in which many aspects of the individual teaching values,…

  19. NWS Marine, Tropical, and Tsunami Services Branch Feedback

    Science.gov Websites

    Service NWS logo - Click to go to the NWS homepage Marine Forecasts Marine Forecasts Home News Organization Search Landlubber's forecast: "City, St" or zip code (Pan/Zoom for Marine) Search by Office Marine, Tropical, and Tsunami Services Branch Items of Interest Marine Forecasts Text, Graphic

  20. Scaling Up and Zooming In: Big Data and Personalization in Language Learning

    ERIC Educational Resources Information Center

    Godwin-Jones, Robert

    2017-01-01

    From its earliest days, practitioners of computer-assisted language learning (CALL) have collected data from computer-mediated learning environments. Indeed, that has been a central aspect of the field from the beginning. Usage logs provided valuable insights into how systems were used and how effective they were for language learning. That…

  1. Zooming in and Out: Exploring Teacher Competencies in Inclusive Early Childhood Classrooms

    ERIC Educational Resources Information Center

    Lee, Yoon-Joo; Recchia, Susan L.

    2016-01-01

    This study explored issues of social inclusion for young children with disabilities through a systematic reanalysis of six preschool case studies focusing on strategies that teachers used in daily practice. Our analysis process entailed a reexamination of classroom observations and teacher inquiry data, focusing back and forth between the…

  2. Hubble Identifies Source of Ultraviolet Light in an Old Galaxy

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This videotape is comprised of four segments: (1) a Video zoom in on galaxy M32 using ground images, (2) Hubble images of galaxy M32, (3) Ground base color image of galaxies M31 and M32, and (4) Black and white ground based images of galaxy M32.

  3. JF-104 ground testing reaction control system (RCS) jets

    NASA Technical Reports Server (NTRS)

    1961-01-01

    JF-104A (formerly YF-104A, serial # 55-2961) was modifed with a hydrogen peroxide reaction control system (RCS). Following a zoom climb to altitudes in the vicinity of 80,000 feet, the RCS system gave the aircraft controllability in the thin upper atmosphere where conventional control surfaces are ineffective.

  4. Using Videoconferencing to Create Authentic Online Learning for Volunteers

    ERIC Educational Resources Information Center

    Lobley, Jennifer; Ouellette, Kristy L.

    2017-01-01

    Face-to-face training for Extension volunteers is no longer the only viable delivery mode. In times of rapid technological advances, we are faced with a plethora of options for offering volunteers the training and support they need. Zoom, an online videoconferencing platform, can easily be used to engage volunteers in professional development.…

  5. Fine-Tuned: Phonology and Semantics Affect First- to Second-Language Zooming In

    ERIC Educational Resources Information Center

    Elston-Guttler, Kerrie E.; Gunter, Thomas C.

    2009-01-01

    We investigate how L1 phonology and semantics affect processing of interlingual homographs by manipulating language context before, and auditory input during, a visual experiment in the L2. Three experiments contained German-English homograph primes ("gift" = German "poison") in English sentences and was performed by German (L1) learners of…

  6. The Lived Experience: A Study in Teaching Online

    ERIC Educational Resources Information Center

    Morgan, Bobbette M.

    2018-01-01

    A researcher with five years' experience of teaching online classes shares what she has seen and experienced while working with her students. Through the evolution of working with Tegrity, Collaborate, and ZOOM the author shares the lived experience. The work of Max van Manen, a phenomenological researcher, serves as the framework. Descriptions…

  7. Fast algorithm for chirp transforms with zooming-in ability and its applications.

    PubMed

    Deng, X; Bihari, B; Gan, J; Zhao, F; Chen, R T

    2000-04-01

    A general fast numerical algorithm for chirp transforms is developed by using two fast Fourier transforms and employing an analytical kernel. This new algorithm unifies the calculations of arbitrary real-order fractional Fourier transforms and Fresnel diffraction. Its computational complexity is better than a fast convolution method using Fourier transforms. Furthermore, one can freely choose the sampling resolutions in both x and u space and zoom in on any portion of the data of interest. Computational results are compared with analytical ones. The errors are essentially limited by the accuracy of the fast Fourier transforms and are higher than the order 10(-12) for most cases. As an example of its application to scalar diffraction, this algorithm can be used to calculate near-field patterns directly behind the aperture, 0 < or = z < d2/lambda. It compensates another algorithm for Fresnel diffraction that is limited to z > d2/lambdaN [J. Opt. Soc. Am. A 15, 2111 (1998)]. Experimental results from waveguide-output microcoupler diffraction are in good agreement with the calculations.

  8. A metadata-aware application for remote scoring and exchange of tissue microarray images

    PubMed Central

    2013-01-01

    Background The use of tissue microarrays (TMA) and advances in digital scanning microscopy has enabled the collection of thousands of tissue images. There is a need for software tools to annotate, query and share this data amongst researchers in different physical locations. Results We have developed an open source web-based application for remote scoring of TMA images, which exploits the value of Microsoft Silverlight Deep Zoom to provide a intuitive interface for zooming and panning around digital images. We use and extend existing XML-based standards to ensure that the data collected can be archived and that our system is interoperable with other standards-compliant systems. Conclusion The application has been used for multi-centre scoring of TMA slides composed of tissues from several Phase III breast cancer trials and ten different studies participating in the International Breast Cancer Association Consortium (BCAC). The system has enabled researchers to simultaneously score large collections of TMA and export the standardised data to integrate with pathological and clinical outcome data, thereby facilitating biomarker discovery. PMID:23635078

  9. Sedna Orbit Comparisons

    NASA Image and Video Library

    2004-03-15

    These four panels show the location of the newly discovered planet-like object, dubbed "Sedna," which lies in the farthest reaches of our solar system. Each panel, moving counterclockwise from the upper left, successively zooms out to place Sedna in context. The first panel shows the orbits of the inner planets, including Earth, and the asteroid belt that lies between Mars and Jupiter. In the second panel, Sedna is shown well outside the orbits of the outer planets and the more distant Kuiper Belt objects. Sedna's full orbit is illustrated in the third panel along with the object's current location. Sedna is nearing its closest approach to the Sun; its 10,000 year orbit typically takes it to far greater distances. The final panel zooms out much farther, showing that even this large elliptical orbit falls inside what was previously thought to be the inner edge of the Oort cloud. The Oort cloud is a spherical distribution of cold, icy bodies lying at the limits of the Sun's gravitational pull. Sedna's presence suggests that this Oort cloud is much closer than scientists believed. http://photojournal.jpl.nasa.gov/catalog/PIA05569

  10. Sedna Orbit Comparisons

    NASA Technical Reports Server (NTRS)

    2004-01-01

    These four panels show the location of the newly discovered planet-like object, dubbed 'Sedna,' which lies in the farthest reaches of our solar system. Each panel, moving counterclockwise from the upper left, successively zooms out to place Sedna in context. The first panel shows the orbits of the inner planets, including Earth, and the asteroid belt that lies between Mars and Jupiter. In the second panel, Sedna is shown well outside the orbits of the outer planets and the more distant Kuiper Belt objects. Sedna's full orbit is illustrated in the third panel along with the object's current location. Sedna is nearing its closest approach to the Sun; its 10,000 year orbit typically takes it to far greater distances. The final panel zooms out much farther, showing that even this large elliptical orbit falls inside what was previously thought to be the inner edge of the Oort cloud. The Oort cloud is a spherical distribution of cold, icy bodies lying at the limits of the Sun's gravitational pull. Sedna's presence suggests that this Oort cloud is much closer than scientists believed.

  11. Multi-focused geospatial analysis using probes.

    PubMed

    Butkiewicz, Thomas; Dou, Wenwen; Wartell, Zachary; Ribarsky, William; Chang, Remco

    2008-01-01

    Traditional geospatial information visualizations often present views that restrict the user to a single perspective. When zoomed out, local trends and anomalies become suppressed and lost; when zoomed in for local inspection, spatial awareness and comparison between regions become limited. In our model, coordinated visualizations are integrated within individual probe interfaces, which depict the local data in user-defined regions-of-interest. Our probe concept can be incorporated into a variety of geospatial visualizations to empower users with the ability to observe, coordinate, and compare data across multiple local regions. It is especially useful when dealing with complex simulations or analyses where behavior in various localities differs from other localities and from the system as a whole. We illustrate the effectiveness of our technique over traditional interfaces by incorporating it within three existing geospatial visualization systems: an agent-based social simulation, a census data exploration tool, and an 3D GIS environment for analyzing urban change over time. In each case, the probe-based interaction enhances spatial awareness, improves inspection and comparison capabilities, expands the range of scopes, and facilitates collaboration among multiple users.

  12. Inspection of aeronautical mechanical parts with a pan-tilt-zoom camera: an approach guided by the computer-aided design model

    NASA Astrophysics Data System (ADS)

    Viana, Ilisio; Orteu, Jean-José; Cornille, Nicolas; Bugarin, Florian

    2015-11-01

    We focus on quality control of mechanical parts in aeronautical context using a single pan-tilt-zoom (PTZ) camera and a computer-aided design (CAD) model of the mechanical part. We use the CAD model to create a theoretical image of the element to be checked, which is further matched with the sensed image of the element to be inspected, using a graph theory-based approach. The matching is carried out in two stages. First, the two images are used to create two attributed graphs representing the primitives (ellipses and line segments) in the images. In the second stage, the graphs are matched using a similarity function built from the primitive parameters. The similarity scores of the matching are injected in the edges of a bipartite graph. A best-match-search procedure in the bipartite graph guarantees the uniqueness of the match solution. The method achieves promising performance in tests with synthetic data including missing elements, displaced elements, size changes, and combinations of these cases. The results open good prospects for using the method with realistic data.

  13. Unique capabilities for ICF and HEDP research with the KrF laser

    NASA Astrophysics Data System (ADS)

    Obenschain, Stephen; Bates, Jason; Chan, Lop-Yung; Karasik, Max; Kehne, David; Sethian, John; Serlin, Victor; Weaver, James; Oh, Jaechul; Jenkins, Bruce; Lehmberg, Robert; Hegeler, Frank; Terrell, Stephen; Aglitskiy, Yefim; Schmitt, Andrew

    2014-10-01

    The krypton-fluoride (KrF) laser provides the shortest wavelength, broadest bandwidth and most uniform target illumination of all developed high-energy lasers. For directly driven targets these characteristics result in higher and more uniform ablation pressures as well as higher intensity thresholds for laser-plasma instability. The ISI beam smoothing scheme implemented on the NRL Nike KrF facility allows easy implementation of focal zooming where the laser radial profile is varied during the laser pulse. The capability for near continuous zooming with KrF would be valuable towards minimizing the effects of cross beam energy transport (CBET) in directly driven capsule implosions. The broad bandwidth ISI beam smoothing that is utilized with the Nike KrF facility may further inhibit certain laser plasma instability. In this presentation we will summarize our current understanding of laser target interaction with the KrF laser and the benefits it provides for ICF and certain HEDP experiments. Status and progress in high-energy KrF laser technology will also be discussed. Work supported by the Deparment of Energy, NNSA.

  14. HI and Low Metal Ions at the Intersection of Galaxies and the CGM

    NASA Astrophysics Data System (ADS)

    Oppenheimer, Benjamin

    2017-08-01

    Over 1000 COS orbits have revealed a surprisingly complex picture of circumgalactic gas flows surrounding the diversity of galaxies in the evolved Universe. Cosmological hydrodynamic simulations have only begun to confront the vast amount of galaxy formation physics, chemistry, and dynamics revealed in the multi-ion CGM datasets. We propose the next generation of EAGLE zoom simulations, called EAGLE Cosmic Origins, to model HI and low metal ions (C II, Mg II, & Si II) throughout not just the CGM but also within the galaxies themselves. We will employ a novel, new chemistry solver, CHIMES, to follow time-dependent ionization, chemistry, and cooling of 157 ionic and molecular species, and include multiple ionization sources from the extra-galactic background, episodic AGN, and star formation. Our aim is to understand the complete baryon cycle of inflows, outflows, and gas recycling traced over 10 decades of HI column densities as well as the complex kinematic information encoded low ion absorption spectroscopy. This simulation project represents a pilot program for a larger suite of zoom simulations, which will be publicly released and lead to additional publications.

  15. 24 CFR 1000.542 - When may HUD require replacement of a recipient?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT NATIVE AMERICAN HOUSING ACTIVITIES Recipient Monitoring... practice of activities that constitute substantial or willful noncompliance with the requirements of...

  16. 24 CFR 1000.542 - When may HUD require replacement of a recipient?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT NATIVE AMERICAN HOUSING ACTIVITIES Recipient Monitoring... practice of activities that constitute substantial or willful noncompliance with the requirements of...

  17. 24 CFR 1000.542 - When may HUD require replacement of a recipient?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT NATIVE AMERICAN HOUSING ACTIVITIES Recipient Monitoring... practice of activities that constitute substantial or willful noncompliance with the requirements of...

  18. 24 CFR 1000.542 - When may HUD require replacement of a recipient?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT NATIVE AMERICAN HOUSING ACTIVITIES Recipient Monitoring... practice of activities that constitute substantial or willful noncompliance with the requirements of...

  19. 24 CFR 1000.542 - When may HUD require replacement of a recipient?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT NATIVE AMERICAN HOUSING ACTIVITIES Recipient Monitoring... practice of activities that constitute substantial or willful noncompliance with the requirements of...

  20. Utilizing Non-Contact Stress Measurement System (NSMS) as a Health Monitor

    NASA Technical Reports Server (NTRS)

    Hayes, Terry; Hayes, Bryan; Bynum, Ken

    2011-01-01

    Continuously monitor all 156 blades throughout the entire operating envelope without adversely affecting tunnel conditions or compromise compressor shell integrity, Calculate dynamic response and identify the frequency/mode to determine individual blade deflection amplitudes, natural frequencies, phase, and damping (Q), Log static deflection to build a database of deflection values at certain compressor conditions to use as basis for real-time online Blade Stack monitor, Monitor for stall, surge, flutter, and blade damage, Operate with limited user input, low maintenance cost, safe illumination of probes, easy probe replacement, and require little or no access to compressor.

  1. Adaptive runtime for a multiprocessing API

    DOEpatents

    Antao, Samuel F.; Bertolli, Carlo; Eichenberger, Alexandre E.; O'Brien, John K.

    2016-11-15

    A computer-implemented method includes selecting a runtime for executing a program. The runtime includes a first combination of feature implementations, where each feature implementation implements a feature of an application programming interface (API). Execution of the program is monitored, and the execution uses the runtime. Monitor data is generated based on the monitoring. A second combination of feature implementations are selected, by a computer processor, where the selection is based at least in part on the monitor data. The runtime is modified by activating the second combination of feature implementations to replace the first combination of feature implementations.

  2. Adaptive runtime for a multiprocessing API

    DOEpatents

    Antao, Samuel F.; Bertolli, Carlo; Eichenberger, Alexandre E.; O'Brien, John K.

    2016-10-11

    A computer-implemented method includes selecting a runtime for executing a program. The runtime includes a first combination of feature implementations, where each feature implementation implements a feature of an application programming interface (API). Execution of the program is monitored, and the execution uses the runtime. Monitor data is generated based on the monitoring. A second combination of feature implementations are selected, by a computer processor, where the selection is based at least in part on the monitor data. The runtime is modified by activating the second combination of feature implementations to replace the first combination of feature implementations.

  3. Surface plasmon resonance application for herbicide detection

    NASA Astrophysics Data System (ADS)

    Chegel, Vladimir I.; Shirshov, Yuri M.; Piletskaya, Elena V.; Piletsky, Sergey A.

    1998-01-01

    The optoelectronic biosensor, based on Surface Plasmon Resonance (SPR) for detection of photosynthesis-inhibiting herbicides in aqueous solutions is presented. The pesticide capability to replace plastoquinone from its complex with D1 protein is used for the detection. This replacement reaction results in the changes of the optical characteristics of protein layer, immobilized on the gold surface. Monitoring of these changes with SPR-technique permit to determine 0.1 - 5.0 mkg/ml herbicide in solution within one hour.

  4. Surface plasmon resonance application for herbicide detection

    NASA Astrophysics Data System (ADS)

    Chegel, Vladimir I.; Shirshov, Yuri M.; Piletskaya, Elena V.; Piletsky, Sergey A.

    1997-12-01

    The optoelectronic biosensor, based on Surface Plasmon Resonance (SPR) for detection of photosynthesis-inhibiting herbicides in aqueous solutions is presented. The pesticide capability to replace plastoquinone from its complex with D1 protein is used for the detection. This replacement reaction results in the changes of the optical characteristics of protein layer, immobilized on the gold surface. Monitoring of these changes with SPR-technique permit to determine 0.1 - 5.0 mkg/ml herbicide in solution within one hour.

  5. Prospective monitoring improves outcomes of primary total hip replacement: a cohort study

    PubMed Central

    Streubel, Philipp N; Pachón, Marcela; Kerguelén, Carlos A; Navas, José; Portocarrero, Julio; Pesantez, Rodrigo F; Zayed, Gamal; Carrillo, Germán; Llinás, Adolfo M

    2009-01-01

    Background Over the past decade several studies have questioned current standards of patient safety in health care delivery. In response, our institution started a clinical pathway for total hip replacement in 1996. Prospective monitoring with regular feedback sessions to the individuals involved in patient care did however not start until 2003. The present study evaluates the effect of prospective monitoring on outcomes of total hip replacement. Methods Clinical records of patients undergoing primary elective total hip replacement between 1997 and 2004 were reviewed. Data on adverse events as well as adherence to protocols for venous thromboembolism prophylaxis were extracted retrospectively for the period 1997 to 2001 and prospectively from 2003 to 2004. Results were compared and analyzed in order to establish possible improvement in outcomes. Data was analyzed with Chi-square or Fisher's Exact test for categorical variables and Student's t-test for continuous variables. Alpha was set as less than 5% and analysis was performed with Stata 9.0 for Macintosh. Results Two-hundred and eighty-three patients were included from 1997 to 2001, and 62 from 2003 to 2004. Mean age, male to female ratio and initial diagnosis were similar in both groups. At least one adverse event occurred in 45% of patients in 1997–2001 and in 21% in 2003–2004 (p < 0.001). In-hospital hip dislocations occurred in 6% and 0% (p = 0.05), oliguria in 19% and 5% (p = 0.007), SSI and VTE in 3% and 0% (p = 0.37), adverse drug reactions in 11% and 13% (p = 0.66) and non-adherence to VTE prophylaxis protocols in 15% and 2% of cases respectively (p = 0.002). Conclusion Overall rate of adverse events as well as in-hospital hip dislocations, oliguria and non-adherence to VTE prophylaxis protocols were significantly reduced during the second period. We conclude that clinical pathways alone are insufficient to improve patient safety and require prospective monitoring and continuous feedback to health care providers in order to achieve the desired effect. PMID:19366438

  6. A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.

    PubMed

    Figl, Michael; Ede, Christopher; Hummel, Johann; Wanschitz, Felix; Ewers, Rolf; Bergmann, Helmar; Birkfellner, Wolfgang

    2005-11-01

    Ever since the development of the first applications in image-guided therapy (IGT), the use of head-mounted displays (HMDs) was considered an important extension of existing IGT technologies. Several approaches to utilizing HMDs and modified medical devices for augmented reality (AR) visualization were implemented. These approaches include video-see through systems, semitransparent mirrors, modified endoscopes, and modified operating microscopes. Common to all these devices is the fact that a precise calibration between the display and three-dimensional coordinates in the patient's frame of reference is compulsory. In optical see-through devices based on complex optical systems such as operating microscopes or operating binoculars-as in the case of the system presented in this paper-this procedure can become increasingly difficult since precise camera calibration for every focus and zoom position is required. We present a method for fully automatic calibration of the operating binocular Varioscope M5 AR for the full range of zoom and focus settings available. Our method uses a special calibration pattern, a linear guide driven by a stepping motor, and special calibration software. The overlay error in the calibration plane was found to be 0.14-0.91 mm, which is less than 1% of the field of view. Using the motorized calibration rig as presented in the paper, we were also able to assess the dynamic latency when viewing augmentation graphics on a mobile target; spatial displacement due to latency was found to be in the range of 1.1-2.8 mm maximum, the disparity between the true object and its computed overlay represented latency of 0.1 s. We conclude that the automatic calibration method presented in this paper is sufficient in terms of accuracy and time requirements for standard uses of optical see-through systems in a clinical environment.

  7. Open source tools for management and archiving of digital microscopy data to allow integration with patient pathology and treatment information

    PubMed Central

    2013-01-01

    Background Virtual microscopy includes digitisation of histology slides and the use of computer technologies for complex investigation of diseases such as cancer. However, automated image analysis, or website publishing of such digital images, is hampered by their large file sizes. Results We have developed two Java based open source tools: Snapshot Creator and NDPI-Splitter. Snapshot Creator converts a portion of a large digital slide into a desired quality JPEG image. The image is linked to the patient’s clinical and treatment information in a customised open source cancer data management software (Caisis) in use at the Australian Breast Cancer Tissue Bank (ABCTB) and then published on the ABCTB website (http://www.abctb.org.au) using Deep Zoom open source technology. Using the ABCTB online search engine, digital images can be searched by defining various criteria such as cancer type, or biomarkers expressed. NDPI-Splitter splits a large image file into smaller sections of TIFF images so that they can be easily analysed by image analysis software such as Metamorph or Matlab. NDPI-Splitter also has the capacity to filter out empty images. Conclusions Snapshot Creator and NDPI-Splitter are novel open source Java tools. They convert digital slides into files of smaller size for further processing. In conjunction with other open source tools such as Deep Zoom and Caisis, this suite of tools is used for the management and archiving of digital microscopy images, enabling digitised images to be explored and zoomed online. Our online image repository also has the capacity to be used as a teaching resource. These tools also enable large files to be sectioned for image analysis. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5330903258483934 PMID:23402499

  8. Conference on asbestos control and replacement for electric utilities: Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    An EPRI conference on Asbestos Control and Replacement for Electric Utilities was held April 9, 1992 in conjunction with the National Asbestos Council`s Environmental Management 192 Conference and Exposition. The high cost and potential liabilities of asbestos removal projects, compounded by concerns over the health effects of asbestos replacement materials, was the main motivation for the conference. The objective of the conference was to assemble guidance and information that will help utilities manage asbestos and to effectively prioritize EPRI research in this area. Ten papers covered such topics as computer-aided asbestos management, utility experience with asbestos management, asbestos monitoring andmore » disposal, and asbestos replacement materials. Utility feedback received at the conference indicates that present and planned EPRI research activities in this area will effectively meet industry needs.« less

  9. NASA Planetary Visualization Tool

    NASA Astrophysics Data System (ADS)

    Hogan, P.; Kim, R.

    2004-12-01

    NASA World Wind allows one to zoom from satellite altitude into any place on Earth, leveraging the combination of high resolution LandSat imagery and SRTM elevation data to experience Earth in visually rich 3D, just as if they were really there. NASA World Wind combines LandSat 7 imagery with Shuttle Radar Topography Mission (SRTM) elevation data, for a dramatic view of the Earth at eye level. Users can literally fly across the world's terrain from any location in any direction. Particular focus was put into the ease of usability so people of all ages can enjoy World Wind. All one needs to control World Wind is a two button mouse. Additional guides and features can be accessed though a simplified menu. Navigation is automated with single clicks of a mouse as well as the ability to type in any location and automatically zoom to it. NASA World Wind was designed to run on recent PC hardware with the same technology used by today's 3D video games. NASA World Wind delivers the NASA Blue Marble, spectacular true-color imagery of the entire Earth at 1-kilometer-per-pixel. Using NASA World Wind, you can continue to zoom past Blue Marble resolution to seamlessly experience the extremely detailed mosaic of LandSat 7 data at an impressive 15-meters-per-pixel resolution. NASA World Wind also delivers other color bands such as the infrared spectrum. The NASA Scientific Visualization Studio at Goddard Space Flight Center (GSFC) has produced a set of visually intense animations that demonstrate a variety of subjects such as hurricane dynamics and seasonal changes across the globe. NASA World Wind takes these animations and plays them directly on the world. The NASA Moderate Resolution Imaging Spectroradiometer (MODIS) produces a set of time relevant planetary imagery that's updated every day. MODIS catalogs fires, floods, dust, smoke, storms and volcanic activity. NASA World Wind produces an easily customized view of this information and marks them directly on the globe. When one of these color coded markers are clicked, it downloads the full image and displays it in the full context of its location on Earth. MODIS images are publication quality material at resolutions up to 250-meters-per-pixel. NASA World Wind provides a full catalog of countries, capitals, counties, cities, towns, and even historical references. The names appear dynamically, increasing in number as the user zooms in. World Wind is capable of browsing through and displaying GLOBE data based on any date one wishes planetary data for. That means one can download today's (or any previous day's) temperature across the world, or rainfall, barometric pressure, cloud cover, or even the GLOBE students' global distribution of collected data. This program is free and available for further development via the NASA Open Source Agreement guidelines.

  10. A web-application for visualizing uncertainty in numerical ensemble models

    NASA Astrophysics Data System (ADS)

    Alberti, Koko; Hiemstra, Paul; de Jong, Kor; Karssenberg, Derek

    2013-04-01

    Numerical ensemble models are used in the analysis and forecasting of a wide range of environmental processes. Common use cases include assessing the consequences of nuclear accidents, pollution releases into the ocean or atmosphere, forest fires, volcanic eruptions, or identifying areas at risk from such hazards. In addition to the increased use of scenario analyses and model forecasts, the availability of supplementary data describing errors and model uncertainties is increasingly commonplace. Unfortunately most current visualization routines are not capable of properly representing uncertain information. As a result, uncertainty information is not provided at all, not readily accessible, or it is not communicated effectively to model users such as domain experts, decision makers, policy makers, or even novice users. In an attempt to address these issues a lightweight and interactive web-application has been developed. It makes clear and concise uncertainty visualizations available in a web-based mapping and visualization environment, incorporating aggregation (upscaling) techniques to adjust uncertainty information to the zooming level. The application has been built on a web mapping stack of open source software, and can quantify and visualize uncertainties in numerical ensemble models in such a way that both expert and novice users can investigate uncertainties present in a simple ensemble dataset. As a test case, a dataset was used which forecasts the spread of an airborne tracer across Western Europe. Extrinsic uncertainty representations are used in which dynamic circular glyphs are overlaid on model attribute maps to convey various uncertainty concepts. It supports both basic uncertainty metrics such as standard deviation, standard error, width of the 95% confidence interval and interquartile range, as well as more experimental ones aimed at novice users. Ranges of attribute values can be specified, and the circular glyphs dynamically change size to represent the probability of the attribute value falling within the specified interval. For more advanced users graphs of the cumulative probability density function, histograms, and time series plume charts are available. To avoid risking a cognitive overload and crowding of glyphs on the map pane, the support of the data used for generating the glyphs is linked dynamically to the zoom level. Zooming in and out respectively decreases and increases the underlying support size of data used for generating the glyphs, thereby making uncertainty information of the original data upscaled to the resolution of the visualization accessible to the user. This feature also ensures that the glyphs are neatly spaced in a regular grid regardless of the zoom level. Finally, the web-application has been presented to groups of test users of varying degrees of expertise in order to evaluate the usability of the interface and the effectiveness of uncertainty visualizations based on circular glyphs.

  11. A microprocessor-based system for continuous monitoring of radiation levels around the CERN PS and PSB accelerators

    NASA Astrophysics Data System (ADS)

    Agoritsas, V.; Beck, F.; Benincasa, G. P.; Bovigny, J. P.

    1986-06-01

    This paper describes a new beam loss monitor system which has been installed in the PS and PSB machines, replacing an earlier system. The new system is controlled by a microprocessor which can operate independently of the accelerator control system, though setting up and central display are usually done remotely, using the standard control system facilities.

  12. MANAGEMENT OF ENDOCRINE DISEASE: Risk of overtreatment in patients with adrenal insufficiency: current and emerging aspects.

    PubMed

    Mazziotti, G; Formenti, A M; Frara, S; Roca, E; Mortini, P; Berruti, A; Giustina, A

    2017-11-01

    The effects of long-term replacement therapy of adrenal insufficiency (AI) are still a matter of controversy. In fact, the established glucocorticoid replacement regimens do not completely reproduce the endogenous hormonal production and the monitoring of AI treatment may be a challenge for the lack of reliable clinical and biochemical markers. Consequently, several AI patients are frequently exposed to relative glucocorticoid excess potentially leading to develop chronic complications, such as diabetes mellitus, dyslipidemia, hypertension and fragility fractures with consequent impaired QoL and increased mortality risk. This review deals with the pathophysiological and clinical aspects concerning the over-replacement therapy of primary and secondary AI. © 2017 European Society of Endocrinology.

  13. The origin of the Milky Way globular clusters

    NASA Astrophysics Data System (ADS)

    Renaud, Florent; Agertz, Oscar; Gieles, Mark

    2017-03-01

    We present a cosmological zoom-in simulation of a Milky Way-like galaxy used to explore the formation and evolution of star clusters. We investigate in particular the origin of the bimodality observed in the colour and metallicity of globular clusters, and the environmental evolution through cosmic times in the form of tidal tensors. Our results self-consistently confirm previous findings that the blue, metal-poor clusters form in satellite galaxies that are accreted on to the Milky Way, while the red, metal-rich clusters form mostly in situ, or, to a lower extent, in massive, self-enriched galaxies merging with the Milky Way. By monitoring the tidal fields these populations experience, we find that clusters formed in situ (generally centrally concentrated) feel significantly stronger tides than the accreted ones, both in the present day, and when averaged over their entire life. Furthermore, we note that the tidal field experienced by Milky Way clusters is significantly weaker in the past than at present day, confirming that it is unlikely that a power-law cluster initial mass function like that of young massive clusters, is transformed into the observed peaked distribution in the Milky Way with relaxation-driven evaporation in a tidal field.

  14. The heat-transfer method: a versatile low-cost, label-free, fast, and user-friendly readout platform for biosensor applications.

    PubMed

    van Grinsven, Bart; Eersels, Kasper; Peeters, Marloes; Losada-Pérez, Patricia; Vandenryt, Thijs; Cleij, Thomas J; Wagner, Patrick

    2014-08-27

    In recent years, biosensors have become increasingly important in various scientific domains including medicine, biology, and pharmacology, resulting in an increased demand for fast and effective readout techniques. In this Spotlight on Applications, we report on the recently developed heat-transfer method (HTM) and illustrate the use of the technique by zooming in on four established bio(mimetic) sensor applications: (i) mutation analysis in DNA sequences, (ii) cancer cell identification through surface-imprinted polymers, (iii) detection of neurotransmitters with molecularly imprinted polymers, and (iv) phase-transition analysis in lipid vesicle layers. The methodology is based on changes in heat-transfer resistance at a functionalized solid-liquid interface. To this extent, the device applies a temperature gradient over this interface and monitors the temperature underneath and above the functionalized chip in time. The heat-transfer resistance can be obtained by dividing this temperature gradient by the power needed to achieve a programmed temperature. The low-cost, fast, label-free and user-friendly nature of the technology in combination with a high degree of specificity, selectivity, and sensitivity makes HTM a promising sensor technology.

  15. Intelligent Advanced Communications IP Telephony Feasibility for the U.S. Navy. Volume 1

    DTIC Science & Technology

    2007-10-01

    Monitors Control and Bearer Designed by the There are no bearing Circuitry Health through Non - manufacture of the circuits to be testing in Selectable... controlled process, only replacing non -tactical end devices at first and then replacing tactical when the sailors and the commanding officers build up...looked at as an alternative to the touch screen in a non -software research . A complete review of development of voice is larger then this test bed can

  16. Zooming in on Spatial Scaling: Preschool Children and Adults Use Mental Transformations to Scale Spaces

    ERIC Educational Resources Information Center

    Möhring, Wenke; Newcombe, Nora S.; Frick, Andrea

    2014-01-01

    Spatial scaling is an important prerequisite for many spatial tasks and involves an understanding of how distances in different-sized spaces correspond. Previous studies have found evidence for such an understanding in preschoolers; however, the mental processes involved remain unclear. In the present study, we investigated whether children and…

  17. One Teacher, Two Lessons: The Lesson Study Process

    ERIC Educational Resources Information Center

    Robinson, Naomi; Leikin, Roza

    2012-01-01

    In this paper, we analyze 2 lessons by 1 teacher that took place during a lesson study (LS) cycle for a team of elementary mathematics teachers. We analyze the data on 2 levels: macro-level analysis, dealing with lesson structure and setting; and micro-level analysis, zooming in on mathematical tasks and the quality of whole-class discussion. We…

  18. Building an E-Book Library: Resources for Finding the Best Apps

    ERIC Educational Resources Information Center

    Zipke, Marcy

    2014-01-01

    There is a wide range in the educational qualities and overall quality of interactive storybook apps for tablet computers (ebooks). Minimally, ebooks for young children present illustrations on a screen, accompanied by an oral reading of the text. Today's ebooks can also include animation, zooming in and out, musical scores, sound effects,…

  19. Beyond "Trimming the Fat": The Sub-Editing Stage of Newswriting

    ERIC Educational Resources Information Center

    Vandendaele, Astrid; De Cuypere, Ludovic; Van Praet, Ellen

    2015-01-01

    Thus far, professional editing has not been researched extensively in writing research. This article zooms in on sub-editing in newswriting as a form of professional editing, addressing three research questions: (a) What are the ways in which a news article's text is altered?, (b) Are some types of news article altered more significantly than…

  20. AIS Indexer Development Report

    DTIC Science & Technology

    2014-03-01

    Rev. 8-98) Prescribed by ANSI Std Z39-18 Approved by Approved for release by c© Her Majesty the Queen in Right of Canada as represented by the...same panel and have been tailored for ease of use. 3.2 Map Navigation New map navigation tools allow the user to zoom in and out of a map and drag the

  1. Interpreting and Representing Students' Thinking in the Moment: Preservice Teachers' Initial Number String Lessons

    ERIC Educational Resources Information Center

    Chen, Lizhen; Bofferding, Laura

    2017-01-01

    Being able to effectively interpret students' thinking and respond effectively in the moment are important skills that preservice teachers (PSTs) need to learn. This study zooms in on 14 PSTs' planning, teaching, and reflections involved in number string lessons, and investigates to what extent PSTs anticipate their students' strategies and…

  2. Master Volunteer Life Cycle: A Wide Angle Lens on the Volunteer Experience

    ERIC Educational Resources Information Center

    Strauss, Andrea Lorek; Rager, Amy

    2017-01-01

    Extension master volunteer programs, such as master naturalist and master gardener, often focus heavily on volunteer education. The model presented here describes the full life cycle of a master volunteer's experience in the program, putting education in the context of other essential program components. By zooming out to a wide-angle view of the…

  3. Construction, completion, and testing of replacement monitoring wells MW 3-2, MW 6-2, MW 7-2, and MW 11-2, Mountain Home Air Force Base, Idaho, February through April 2000

    USGS Publications Warehouse

    Parliman, D.J.

    2000-01-01

    In February and March 2000, the U.S. Geological Survey Western Regional Research Drilling Operation constructed replacement monitoring wells MW 3–2, MW 6–2, MW 7–2, and MW 11–2 as part of a regional ground-water monitor- ing network for the Mountain Home Air Force Base, Elmore County, Idaho. Total well depths ranged from 435.5 to 456.5 feet, and initial depth-to-water measurements ranged from about 350 to 375 feet below land surface. After completion, wells were pumped and onsite measurements were made of water temperature, specific conductance, pH, and dissolved oxygen. At each well, natural gamma, spontaneous potential, resistivity, caliper, and temperature logs were obtained from instruments placed in open boreholes. A three- dimensional borehole flow analysis was completed for MW 3–2 and MW 11–2, and a video log was obtained for MW 11–2 to annotate lithology and note wet zones in the borehole above saturated rock.

  4. Fiber-optic sensing in cryogenic environments. [for rocket propellant tank monitoring

    NASA Technical Reports Server (NTRS)

    Sharma, M.; Brooks, R. E.

    1980-01-01

    Passive optical sensors using fiber-optic signal transmission to a remote monitoring station are explored as an alternative to electrical sensors used to monitor the status of explosive propellants. The designs of passive optical sensors measuring liquid level, pressure, and temperature in cryogenic propellant tanks are discussed. Test results for an experimental system incorporating these sensors and operating in liquid nitrogen demonstrate the feasibility of passive sensor techniques and indicate that they can serve as non-hazardous replacements for more conventional measuring equipment in explosive environments.

  5. Device Would Monitor Body Parameters Continuously

    NASA Technical Reports Server (NTRS)

    Cook, Joseph S., Jr.

    1995-01-01

    Proposed miniature electronic circuit continuously measures temperature of human subject. Once mounted on subject's skin with medical adhesive tape, electronic thermometer remains in thermal equilibrium with subject's body; thereafter, no need to wait until thermometer reaches body temperature before taking reading. Design provides for switches used to set alarm alerting medical attendants if subject's temperature exceeds critical level. For use on very young child, electronic thermometer sewed into shirt or other suitable garment; device held in contact with skin, and child could not swallow it. Replacement of sensor and computing algorithm changes temperature monitor to cardiorespiratory monitor.

  6. β-Hydroxybutyrate supports synaptic vesicle cycling but reduces endocytosis and exocytosis in rat brain synaptosomes.

    PubMed

    Hrynevich, Sviatlana V; Waseem, Tatyana V; Hébert, Audrey; Pellerin, Luc; Fedorovich, Sergei V

    2016-02-01

    The ketogenic diet is used as a prophylactic treatment for different types of brain diseases, such as epilepsy or Alzheimer's disease. In such a diet, carbohydrates are replaced by fats in everyday food, resulting in an elevation of blood-borne ketone bodies levels. Despite clinical applications of this treatment, the molecular mechanisms by which the ketogenic diet exerts its beneficial effects are still uncertain. In this study, we investigated the effect of replacing glucose by the ketone body β-hydroxybutyrate as the main energy substrate on synaptic vesicle recycling in rat brain synaptosomes. First, we observed that exposing presynaptic terminals to nonglycolytic energy substrates instead of glucose did not alter the plasma membrane potential. Next, we found that synaptosomes were able to maintain the synaptic vesicle cycle monitored with the fluorescent dye acridine orange when glucose was replaced by β-hydroxybutyrate. However, in presence of β-hydroxybutyrate, synaptic vesicle recycling was modified with reduced endocytosis. Replacing glucose by pyruvate also led to a reduced endocytosis. Addition of β-hydroxybutyrate to glucose-containing incubation medium was without effect. Reduced endocytosis in presence of β-hydroxybutyrate as sole energy substrate was confirmed using the fluorescent dye FM2-10. Also we found that replacement of glucose by ketone bodies leads to inhibition of exocytosis, monitored by FM2-10. However this reduction was smaller than the effect on endocytosis under the same conditions. Using both acridine orange in synaptosomes and the genetically encoded sensor synaptopHluorin in cortical neurons, we observed that replacing glucose by β-hydroxybutyrate did not modify the pH gradient of synaptic vesicles. In conclusion, the nonglycolytic energy substrates β-hydroxybutyrate and pyruvate are able to support synaptic vesicle recycling. However, they both reduce endocytosis. Reduction of both endocytosis and exocytosis together with misbalance between endocytosis and exocytosis could be involved in the anticonvulsant activity of the ketogenic diet. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Monitoring and evaluation of wire mesh forming life

    NASA Astrophysics Data System (ADS)

    Enemuoh, Emmanuel U.; Zhao, Ping; Kadlec, Alec

    2018-03-01

    Forming tables are used with stainless steel wire mesh conveyor belts to produce variety of products. The forming tables will typically run continuously for several days, with some hours of scheduled downtime for maintenance, cleaning and part replacement after several weeks of operation. The wire mesh conveyor belts show large variation in their remaining life due to associated variations in their nominal thicknesses. Currently the industry is dependent on seasoned operators to determine the replacement time for the wire mesh formers. The drawback of this approach is inconsistency in judgements made by different operators and lack of data knowledge that can be used to develop decision making system that will be more consistent with wire mesh life prediction and replacement time. In this study, diagnostic measurements about the health of wire mesh former is investigated and developed. The wire mesh quality characteristics considered are thermal measurement, tension property, gage thickness, and wire mesh wear. The results show that real time thermal sensor and wear measurements would provide suitable data for the estimation of wire mesh failure, therefore, can be used as a diagnostic parameter for developing structural health monitoring (SHM) system for stainless steel wire mesh formers.

  8. What is the best approach to tailoring hydrocortisone dose to meet patient needs in 2012?

    PubMed

    Debono, Miguel; Ross, Richard J

    2013-05-01

    Cortisol is an essential stress hormone and replacement with oral hydrocortisone is lifesaving in patients with adrenal insufficiency. Cortisol has a diurnal rhythm regulated by the central body clock and this rhythm is a metabolic signal for peripheral tissue clocks. Loss of cortisol rhythmicity is associated with fatigue, depression and insulin resistance. A general principle in endocrinology is to replace hormones to replicate physiological concentrations; however, the pharmacokinetics of oral immediate-release hydrocortisone make it impossible to fully mimic the cortisol rhythm and patients still have an increased morbidity and mortality despite replacement. Traditionally, physicians have replaced hydrocortisone with a total daily dose based on the diurnal 24-h cortisol production rate with hydrocortisone given twice or thrice daily, with the highest dose first thing in the morning. Monitoring treatment and dose titration has been much debated with some clinicians using cortisol day curves and others relying on clinical symptoms. The main challenge is that there is no established biomarker of cortisol activity. In addressing the clinical question, we have taken the view that an understanding of the cortisol circadian rhythm and hydrocortisone pharmacokinetics is essential when tailoring hydrocortisone dose. Using this approach, we have developed a thrice daily, weight-related, dosing regimen and a pharmacokinetic and clinical method to monitor treatment. Our argument for replicating the cortisol circadian rhythm is based on the observation that disruption of the rhythm is associated with ill health, and the few studies that have compared different treatment regimens. Further studies are required to definitively test the benefits of replacing the cortisol circadian rhythm in patients with adrenal insufficiency. © 2012 Blackwell Publishing Ltd.

  9. Proceedings: Conference on asbestos control and replacement for electric utilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    An EPRI conference on Asbestos Control and Replacement for Electric Utilities was held April 6--7, 1993 in conjunction with the Environmental Information Association`s (formerly National Asbestos Council) Environmental Management `93 Conference and Exposition. The high cost and potential liabilities of asbestos removal projects, compounded by concerns over the health effects of asbestos replacement materials, was the main motivation for the conference. The objective of the conference was to assemble guidance and information that will help utilities manage asbestos and to effectively prioritize EPRI research in this area. Eleven papers covered such topics as changes in the Environmental Protection Agency`s (EPA)more » ban on asbestos, utility experience with asbestos management and abatement, asbestos monitoring and disposal, and asbestos replacement materials. Utility feedback received at the conference indicates that present and planned EPRI research activities in this area will effectively meet industry needs.« less

  10. Circulating Cell-Free Tumour DNA in the Management of Cancer

    PubMed Central

    Francis, Glenn; Stein, Sandra

    2015-01-01

    With the development of new sensitive molecular techniques, circulating cell-free tumour DNA containing mutations can be identified in the plasma of cancer patients. The applications of this technology may result in significant changes to the care and management of cancer patients. Whilst, currently, these “liquid biopsies” are used to supplement the histological diagnosis of cancer and metastatic disease, in the future these assays may replace the need for invasive procedures. Applications include the monitoring of tumour burden, the monitoring of minimal residual disease, monitoring of tumour heterogeneity, monitoring of molecular resistance and early diagnosis of tumours and metastatic disease. PMID:26101870

  11. Robust Multimodal Cognitive Load Measurement (RMCLM)

    DTIC Science & Technology

    2013-03-26

    Physiological characteristics of capacity constraints in working memory as revealed by functional MRI , Cerebral Cortex, vol. 9, pp. 20-26, 1999. [12...frequency can easily be ex- tracted in real time and unobtrusively using a tablet monitor or electronic pen, not only can this measure be applied to...basketball clip played on a tablet monitor, which was then frozen and replaced with a blank court schematic. The clips involved 10 players and the

  12. Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2016-02-29

    This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within themore » exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).« less

  13. Fatigue life estimation of a 1D aluminum beam under mode-I loading using the electromechanical impedance technique

    NASA Astrophysics Data System (ADS)

    Lim, Yee Yan; Kiong Soh, Chee

    2011-12-01

    Structures in service are often subjected to fatigue loads. Cracks would develop and lead to failure if left unnoticed after a large number of cyclic loadings. Monitoring the process of fatigue crack propagation as well as estimating the remaining useful life of a structure is thus essential to prevent catastrophe while minimizing earlier-than-required replacement. The advent of smart materials such as piezo-impedance transducers (lead zirconate titanate, PZT) has ushered in a new era of structural health monitoring (SHM) based on non-destructive evaluation (NDE). This paper presents a series of investigative studies to evaluate the feasibility of fatigue crack monitoring and estimation of remaining useful life using the electromechanical impedance (EMI) technique employing a PZT transducer. Experimental tests were conducted to study the ability of the EMI technique in monitoring fatigue crack in 1D lab-sized aluminum beams. The experimental results prove that the EMI technique is very sensitive to fatigue crack propagation. A proof-of-concept semi-analytical damage model for fatigue life estimation has been developed by incorporating the linear elastic fracture mechanics (LEFM) theory into the finite element (FE) model. The prediction of the model matches closely with the experiment, suggesting the possibility of replacing costly experiments in future.

  14. Genetic engineered molecular imaging probes for applications in cell therapy: emphasis on MRI approach

    PubMed Central

    Cho, In K; Wang, Silun; Mao, Hui; Chan, Anthony WS

    2016-01-01

    Recent advances in stem cell-based regenerative medicine, cell replacement therapy, and genome editing technologies (i.e. CRISPR-Cas 9) have sparked great interest in in vivo cell monitoring. Molecular imaging promises a unique approach to noninvasively monitor cellular and molecular phenomena, including cell survival, migration, proliferation, and even differentiation at the whole organismal level. Several imaging modalities and strategies have been explored for monitoring cell grafts in vivo. We begin this review with an introduction describing the progress in stem cell technology, with a perspective toward cell replacement therapy. The importance of molecular imaging in reporting and assessing the status of cell grafts and their relation to the local microenvironment is highlighted since the current knowledge gap is one of the major obstacles in clinical translation of stem cell therapy. Based on currently available imaging techniques, we provide a brief discussion on the pros and cons of each imaging modality used for monitoring cell grafts with particular emphasis on magnetic resonance imaging (MRI) and the reporter gene approach. Finally, we conclude with a comprehensive discussion of future directions of applying molecular imaging in regenerative medicine to emphasize further the importance of correlating cell graft conditions and clinical outcomes to advance regenerative medicine. PMID:27766183

  15. Preferences and motivation for weight loss among knee replacement patients: implications for a patient-centered weight loss intervention.

    PubMed

    Pellegrini, Christine A; Ledford, Gwendolyn; Hoffman, Sara A; Chang, Rowland W; Cameron, Kenzie A

    2017-08-01

    Most knee replacement patients are overweight/obese, yet are commonly excluded from evidence-based weight loss programs due to mobility limitations and barriers faced around the time of surgery. The purpose of this study was to identify knee replacement patient preferences for weight loss programs and qualitatively understand previous motives for weight loss attempts as well as strategies used to facilitate behavior changes. Patients who were either scheduled to have knee replacement or had one recently completed within the last 3 months were recruited to participate. Patients completed a brief weight loss program preference questionnaire assessing preferred components of a weight loss program (i.e. self-monitoring, educational topics, program duration). Qualitative interviews were completed to identify motives for and strategies used during past weight loss attempts. All interviews were transcribed, de-identified, and analyzed using constant comparative analysis. Twenty patients (11 pre-operative and 9 post-operative) between 47 and 79 years completed the study (55% male, 90% White, and 85% with a BMI ≥25 kg/m 2 ). Patients reported a preference for a weight loss program that starts before surgery, is at least 6 months in duration, and focuses both on diet and exercise. The majority of patients preferred to have a telephone-based program and wanted to track diet and physical activity on a smartphone application. The most common motive for weight loss mentioned by patients related to physical appearance (including how clothing fit), followed by wanting to lose weight to improve knee symptoms or to prevent or delay knee replacement. Strategies that patients identified as helpful during weight loss attempts included joining a formal weight loss program, watching portion sizes, and self-monitoring their dietary intake, physical activity, or weight. This study provides a preliminary examination into the motives for weight loss, strategies utilized during past weight loss attempts, and preferences for future weight loss programs as described by knee replacement patients. These results will help guide the development and adaptation of future patient-centered weight loss programs as well as help clinicians recommend targeted weight programs based on the specific preferences of the knee replacement population.

  16. Algorithm design of liquid lens inspection system

    NASA Astrophysics Data System (ADS)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  17. Generator replacement is associated with an increased rate of ICD lead alerts.

    PubMed

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. The shifting zoom: new possibilities for inverse scattering on electrically large domains

    NASA Astrophysics Data System (ADS)

    Persico, Raffaele; Ludeno, Giovanni; Soldovieri, Francesco; De Coster, Alberic; Lambot, Sebastien

    2017-04-01

    Inverse scattering is a subject of great interest in diagnostic problems, which are in their turn of interest for many applicative problems as investigation of cultural heritage, characterization of foundations or subservices, identification of unexploded ordnances and so on [1-4]. In particular, GPR data are usually focused by means of migration algorithms, essentially based on a linear approximation of the scattering phenomenon. Migration algorithms are popular because they are computationally efficient and do not require the inversion of a matrix, neither the calculation of the elements of a matrix. In fact, they are essentially based on the adjoint of the linearised scattering operator, which allows in the end to write the inversion formula as a suitably weighted integral of the data [5]. In particular, this makes a migration algorithm more suitable than a linear microwave tomography inversion algorithm for the reconstruction of an electrically large investigation domain. However, this computational challenge can be overcome by making use of investigation domains joined side by side, as proposed e.g. in ref. [3]. This allows to apply a microwave tomography algorithm even to large investigation domains. However, the joining side by side of sequential investigation domains introduces a problem of limited (and asymmetric) maximum view angle with regard to the targets occurring close to the edges between two adjacent domains, or possibly crossing these edges. The shifting zoom is a method that allows to overcome this difficulty by means of overlapped investigation and observation domains [6-7]. It requires more sequential inversion with respect to adjacent investigation domains, but the really required extra-time is minimal because the matrix to be inverted is calculated ones and for all, as well as its singular value decomposition: what is repeated more time is only a fast matrix-vector multiplication. References [1] M. Pieraccini, L. Noferini, D. Mecatti, C. Atzeni, R. Persico, F. Soldovieri, Advanced Processing Techniques for Step-frequency Continuous-Wave Penetrating Radar: the Case Study of "Palazzo Vecchio" Walls (Firenze, Italy), Research on Nondestructive Evaluation, vol. 17, pp. 71-83, 2006. [2] N. Masini, R. Persico, E. Rizzo, A. Calia, M. T. Giannotta, G. Quarta, A. Pagliuca, "Integrated Techniques for Analysis and Monitoring of Historical Monuments: the case of S.Giovanni al Sepolcro in Brindisi (Southern Italy)." Near Surface Geophysics, vol. 8 (5), pp. 423-432, 2010. [3] E. Pettinelli, A. Di Matteo, E. Mattei, L. Crocco, F. Soldovieri, J. D. Redman, and A. P. Annan, "GPR response from buried pipes: Measurement on field site and tomographic reconstructions", IEEE Transactions on Geoscience and Remote Sensing, vol. 47, n. 8, 2639-2645, Aug. 2009. [4] O. Lopera, E. C. Slob, N. Milisavljevic and S. Lambot, "Filtering soil surface and antenna effects from GPR data to enhance landmine detection", IEEE Transactions on Geoscience and Remote Sensing, vol. 45, n. 3, pp.707-717, 2007. [5] R. Persico, "Introduction to Ground Penetrating Radar: Inverse Scattering and Data Processing". Wiley, 2014. [6] R. Persico, J. Sala, "The problem of the investigation domain subdivision in 2D linear inversions for large scale GPR data", IEEE Geoscience and Remote Sensing Letters, vol. 11, n. 7, pp. 1215-1219, doi 10.1109/LGRS.2013.2290008, July 2014. [7] R. Persico, F. Soldovieri, S. Lambot, Shifting zoom in 2D linear inversions performed on GPR data gathered along an electrically large investigation domain, Proc. 16th International Conference on Ground Penetrating Radar GPR2016, Honk-Kong, June 13-16, 2016

  19. Esophageal replacement in children: Challenges and long-term outcomes.

    PubMed

    Soccorso, Giampiero; Parikh, Dakshesh H

    2016-01-01

    Replacement of a nonexistent or damaged esophagus continues to pose a significant challenge to pediatric surgeons. Various esophageal replacement grafts and techniques have not produced consistently good outcomes to emulate normal esophagus. Therefore, many techniques are still being practiced and recommended with no clear consensus. We present a concise literature review of the currently used techniques and with discussions on the advantages and anticipated morbidity. There are no randomized controlled pediatric studies to compare different types of esophageal replacements. Management and graft choice are based on geographical and personal predilections rather than on any discernible objective data. The biggest series with long-term outcome are reported for gastric transposition and colonic replacement. Comparison of different studies shows no significant difference in early (graft necrosis and anastomotic leaks) or late complications (strictures, poor feeding, gastro-esophageal reflux, tortuosity of the graft, and Barrett's esophagus). The biggest series seem to have lower complications than small series reflecting the decennials experience in their respective centers. Long-term follow-up is recommended following esophageal replacement for the development of late strictures, excessive tortuosity, and Barrett's changes within the graft. Once child overcomes initial morbidity and establishes oral feeding, long-term consequences and complications of pediatric esophageal replacement should be monitored and managed in adult life.

  20. Esophageal replacement in children: Challenges and long-term outcomes

    PubMed Central

    Soccorso, Giampiero; Parikh, Dakshesh H.

    2016-01-01

    Replacement of a nonexistent or damaged esophagus continues to pose a significant challenge to pediatric surgeons. Various esophageal replacement grafts and techniques have not produced consistently good outcomes to emulate normal esophagus. Therefore, many techniques are still being practiced and recommended with no clear consensus. We present a concise literature review of the currently used techniques and with discussions on the advantages and anticipated morbidity. There are no randomized controlled pediatric studies to compare different types of esophageal replacements. Management and graft choice are based on geographical and personal predilections rather than on any discernible objective data. The biggest series with long-term outcome are reported for gastric transposition and colonic replacement. Comparison of different studies shows no significant difference in early (graft necrosis and anastomotic leaks) or late complications (strictures, poor feeding, gastro-esophageal reflux, tortuosity of the graft, and Barrett's esophagus). The biggest series seem to have lower complications than small series reflecting the decennials experience in their respective centers. Long-term follow-up is recommended following esophageal replacement for the development of late strictures, excessive tortuosity, and Barrett's changes within the graft. Once child overcomes initial morbidity and establishes oral feeding, long-term consequences and complications of pediatric esophageal replacement should be monitored and managed in adult life. PMID:27365900

  1. Oral Vitamin B12 Replacement for the Treatment of Pernicious Anemia

    PubMed Central

    Chan, Catherine Qiu Hua; Low, Lian Leng; Lee, Kheng Hock

    2016-01-01

    Many patients with pernicious anemia are treated with lifelong intramuscular (IM) vitamin B12 replacement. As early as the 1950s, there were studies suggesting that oral vitamin B12 replacement may provide adequate absorption. Nevertheless, oral vitamin B12 replacement in patients with pernicious anemia remains uncommon in clinical practice. The objective of this review is to provide an update on the effectiveness of oral vitamin B12 for the treatment of pernicious anemia, the recommended dosage, and the required frequency of laboratory test and clinical monitoring. Relevant articles were identified by PubMed search from January 1, 1980 to March 31, 2016 and through hand search of relevant reference articles. Two randomized controlled trials, three prospective papers, one systematic review, and three clinical reviews fulfilled our inclusion criteria. We found that oral vitamin B12 replacement at 1000 μg daily was adequate to replace vitamin B12 levels in patients with pernicious anemia. We conclude that oral vitamin B12 is an effective alternative to vitamin B12 IM injections. Patients should be offered this alternative after an informed discussion on the advantages and disadvantages of both treatment options. PMID:27602354

  2. Structural health monitoring of wind turbine blades : SE 265 Final Project.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barkley, W. C.; Jacobs, Laura D.; Rutherford, A. C.

    2006-03-23

    ACME Wind Turbine Corporation has contacted our dynamic analysis firm regarding structural health monitoring of their wind turbine blades. ACME has had several failures in previous years. Examples are shown in Figure 1. These failures have resulted in economic loss for the company due to down time of the turbines (lost revenue) and repair costs. Blade failures can occur in several modes, which may depend on the type of construction and load history. Cracking and delamination are some typical modes of blade failure. ACME warranties its turbines and wishes to decrease the number of blade failures they have to repairmore » and replace. The company wishes to implement a real time structural health monitoring system in order to better understand when blade replacement is necessary. Because of warranty costs incurred to date, ACME is interested in either changing the warranty period for the blades in question or predicting imminent failure before it occurs. ACME's current practice is to increase the number of physical inspections when blades are approaching the end of their fatigue lives. Implementation of an in situ monitoring system would eliminate or greatly reduce the need for such physical inspections. Another benefit of such a monitoring system is that the life of any given component could be extended since real conditions would be monitored. The SHM system designed for ACME must be able to operate while the wind turbine is in service. This means that wireless communication options will likely be implemented. Because blade failures occur due to cyclic stresses in the blade material, the sensing system will focus on monitoring strain at various points.« less

  3. Therapeutic drug monitoring of antitubercular agents for disseminated Mycobacterium tuberculosis during intermittent haemodialysis and continuous venovenous haemofiltration.

    PubMed

    Sin, J H; Elshaboury, R H; Hurtado, R M; Letourneau, A R; Gandhi, R G

    2018-04-01

    There is a lack of data regarding therapeutic drug monitoring (TDM) of antitubercular agents in the setting of continuous venovenous haemofiltration (CVVH). We describe TDM results of numerous antitubercular agents in a critically ill patient during CVVH and haemodialysis. A 49-year-old man was initiated on treatment for disseminated Mycobacterium tuberculosis. During hospital admission, the patient developed critical illness and required renal replacement therapy. TDM results and pharmacokinetic calculations showed adequate serum concentrations of rifampin, ethambutol and amikacin during CVVH and of rifampin, pyrazinamide, ethambutol and levofloxacin during intermittent haemodialysis. The presence of critical illness and renal replacement therapy can induce pharmacokinetic changes that may warrant vigilant TDM to ensure optimal therapy. To our knowledge, this is the first report to describe TDM for several antitubercular agents during CVVH in a critically patient with disseminated M. tuberculosis. © 2017 John Wiley & Sons Ltd.

  4. Zooming in and out from the Mental Number Line: Evidence for a Number Range Effect

    ERIC Educational Resources Information Center

    Pinhas, Michal; Pothos, Emmanuel M.; Tzelgov, Joseph

    2013-01-01

    The representation of numbers is commonly viewed as an ordered continuum of magnitudes, referred to as the "mental number line." Previous work has repeatedly shown that number representations evoked by a given task can be easily altered, yielding an ongoing discussion about the basic properties of the mental number line and how malleable…

  5. Race for a Better Fuel Begins with NREL Researchers | News | NREL

    Science.gov Websites

    triptane converted from biomass. Photo by Dennis Schroeder Watching cars zoom around and around an oval NREL's new Fuel Synthesis Catalysis Laboratory. Photo by Dennis Schroeder Any Carbon Source Will Do by Dennis Schroeder Look! Up in the Sky! In addition to race cars, the 85% triptane could find a use

  6. An Investigation of Sensory Information, Levels of Automation, and Piloting Experience on Unmanned Aircraft Pilot Performance

    DTIC Science & Technology

    2012-03-01

    Development.of. NASA - TLX .(Task.Load.Index):.Results.of.empiri- cal.and.theoretical.research ..In.P .A ..Hancock.&.N .. Meshkati.(Eds .),.Human...8 Automated Manual Level of Automation Hi gh Z oo m M an ip ul at io n Pilot Non-pilot Figure 4. Number of participants with high levels of zoom

  7. Zooming In on Copyright with Integrated Library Software Services

    ERIC Educational Resources Information Center

    Oye, Karen

    2007-01-01

    Over the last decade, many of Kelvin Smith Library's (KSL) content delivery services have gone digital, and some, such as enhanced course reserves products, are new to the market. The best digital library services have given KSL options and integrated solutions that allow it to do more than it thought possible just a few years ago. As with many…

  8. Zooming in on the Partnership of a Successful Teaching Team: Examining Cooperation, Action and Recognition

    ERIC Educational Resources Information Center

    Henning Loeb, Ingrid

    2016-01-01

    This article investigates the cooperation of a teaching team in Swedish upper secondary education over a period of five years. The data collection builds on field studies and partly on a collaborative research approach. Three areas of cooperation have been identified: collaboration among the staff; interactions between the staff and the students;…

  9. The Virtual Museum of Minerals and Molecules: Molecular Visualization in a Virtual Hands-On Museum

    ERIC Educational Resources Information Center

    Barak, Phillip; Nater, Edward A.

    2005-01-01

    The Virtual Museum of Minerals and Molecules (VMMM) is a web-based resource presenting interactive, 3-D, research-grade molecular models of more than 150 minerals and molecules of interest to chemical, earth, plant, and environmental sciences. User interactivity with the 3-D display allows models to be rotated, zoomed, and specific regions of…

  10. The Moon and Mars in August

    NASA Astrophysics Data System (ADS)

    Paice, P.

    2003-10-01

    The naked-eye view of the full Moon and Mars together was captured by Peter Paice, Belfast, on 2003 August 12/13 at midnight UT using an Olympus 730 Ultra Zoom digital camera, with no additional processing applied. In a partly cloudy sky, the secret was to wait until clouds partly occluded the power of the Moon, and Mars was in a clear patch.

  11. Ten Things New Teachers Need To Succeed. A SkyLight Guide.

    ERIC Educational Resources Information Center

    Fogarty, Robin

    This guide for novice teachers includes ten sections: (1) "A Knowing Colleague as Counsel...About the Policies, Practices, and Politics!" (proactively seek a mentor); (2) "A Place Called 'My Room' for Students To Grow, To Groom, and To Zoom!" (create a climate that fosters growth and pride); (3) "A Method for Managing 1,500 Decisions: On Your…

  12. Intensive care unit referring physician usage of PACS workstation functions based on disease categories

    NASA Astrophysics Data System (ADS)

    Horii, Steven C.; Kundel, Harold L.; Shile, Peter E.; Carey, Bruce; Seshadri, Sridhar B.; Feingold, Eric R.

    1994-05-01

    As part of a study of the use of a PACS workstation compared to film in a Medical Intensive Care Unit, logs of workstation activity were maintained. The software for the workstation kept track of the type of user (i.e., intern, resident, fellow, or attending physician) and also of the workstation image manipulation functions used. The functions logged were: no operation, brightness/contrast adjustment, invert video, zoom, and high resolution display (this last function resulted in the display of the full 2 K X 2 K image rather than the usual subsampled 1 K X 1 K image. Associated data collection allows us to obtain the diagnostic category of the examination being viewed (e.g., location of tubes and lines, rule out: pneumonia, congestive heart failure, pneumothorax, and pleural effusion). The diagnostic categories and user type were then correlated with the use of workstation functions during viewing of images. In general, there was an inverse relationship between the level of training and the number of workstation uses. About two-thirds of the time, there was no image manipulation operation performed. Adjustment of brightness/contrast had the highest percentage of use overall, followed by zoom, video invert, and high resolution display.

  13. GeneWiz browser: An Interactive Tool for Visualizing Sequenced Chromosomes.

    PubMed

    Hallin, Peter F; Stærfeldt, Hans-Henrik; Rotenberg, Eva; Binnewies, Tim T; Benham, Craig J; Ussery, David W

    2009-09-25

    We present an interactive web application for visualizing genomic data of prokaryotic chromosomes. The tool (GeneWiz browser) allows users to carry out various analyses such as mapping alignments of homologous genes to other genomes, mapping of short sequencing reads to a reference chromosome, and calculating DNA properties such as curvature or stacking energy along the chromosome. The GeneWiz browser produces an interactive graphic that enables zooming from a global scale down to single nucleotides, without changing the size of the plot. Its ability to disproportionally zoom provides optimal readability and increased functionality compared to other browsers. The tool allows the user to select the display of various genomic features, color setting and data ranges. Custom numerical data can be added to the plot allowing, for example, visualization of gene expression and regulation data. Further, standard atlases are pre-generated for all prokaryotic genomes available in GenBank, providing a fast overview of all available genomes, including recently deposited genome sequences. The tool is available online from http://www.cbs.dtu.dk/services/gwBrowser. Supplemental material including interactive atlases is available online at http://www.cbs.dtu.dk/services/gwBrowser/suppl/.

  14. No Heat Spray Drying Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beetz, Charles

    No Heat Spray Drying Technology. ZoomEssence has developed our Zooming™ spray drying technology that atomizes liquids to powders at ambient temperature. The process of drying a liquid into a powder form has been traditionally achieved by mixing a heated gas with an atomized (sprayed) fluid within a vessel (drying chamber) causing the solvent to evaporate. The predominant spray drying process in use today employs air heated up to 400° Fahrenheit to dry an atomized liquid into a powder. Exposing sensitive, volatile liquid ingredients to high temperature causes molecular degradation that negatively impacts solubility, stability and profile of the powder. Inmore » short, heat is detrimental to many liquid ingredients. The completed award focused on several areas in order to advance the prototype dryer to a commercial scale integrated pilot system. Prior to the award, ZoomEssence had developed a prototype ‘no-heat’ dryer that firmly established the feasibility of the Zooming™ process. The award focused on three primary areas to improve the technology: (1) improved ability to formulate emulsions for specific flavor groups and improved understanding of the relationship of emulsion properties to final dry particle properties, (2) a new production atomizer, and (3) a dryer controls system.« less

  15. Common Analysis Tool Being Developed for Aeropropulsion: The National Cycle Program Within the Numerical Propulsion System Simulation Environment

    NASA Technical Reports Server (NTRS)

    Follen, Gregory J.; Naiman, Cynthia G.

    1999-01-01

    The NASA Lewis Research Center is developing an environment for analyzing and designing aircraft engines-the Numerical Propulsion System Simulation (NPSS). NPSS will integrate multiple disciplines, such as aerodynamics, structure, and heat transfer, and will make use of numerical "zooming" on component codes. Zooming is the coupling of analyses at various levels of detail. NPSS uses the latest computing and communication technologies to capture complex physical processes in a timely, cost-effective manner. The vision of NPSS is to create a "numerical test cell" enabling full engine simulations overnight on cost-effective computing platforms. Through the NASA/Industry Cooperative Effort agreement, NASA Lewis and industry partners are developing a new engine simulation called the National Cycle Program (NCP). NCP, which is the first step toward NPSS and is its initial framework, supports the aerothermodynamic system simulation process for the full life cycle of an engine. U.S. aircraft and airframe companies recognize NCP as the future industry standard common analysis tool for aeropropulsion system modeling. The estimated potential payoff for NCP is a $50 million/yr savings to industry through improved engineering productivity.

  16. An organic jelly made fractal logic gate with an infinite truth table

    PubMed Central

    Ghosh, Subrata; Fujita, Daisuke; Bandyopadhyay, Anirban

    2015-01-01

    Widely varying logic gates invented over a century are all finite. As data deluge problem looms large on the information processing and communication industry, the thrust to explore radical concepts is increasing rapidly. Here, we design and synthesis a molecule, wherein, the input energy transmits in a cycle inside the molecular system, just like an oscillator, then, we use the molecule to make a jelly that acts as chain of oscillators with a fractal like resonance band. Hence, with the increasing detection resolution, in the vacant space between two energy levels of a given resonance band, a new band appears, due to fractal nature, generation of newer energy levels never stops. This is natural property of a linear chain oscillator. As we correlate each energy level of the resonance band of organic jelly, as a function of pH and density of the jelly, we realize a logic gate, whose truth table is finite, but if we zoom any small part, a new truth table appears. In principle, zooming of truth table would continue forever. Thus, we invent a new class of infinite logic gate for the first time. PMID:26086417

  17. Dynamic single-cell NAD(P)H measurement reveals oscillatory metabolism throughout the E. coli cell division cycle.

    PubMed

    Zhang, Zheng; Milias-Argeitis, Andreas; Heinemann, Matthias

    2018-02-01

    Recent work has shown that metabolism between individual bacterial cells in an otherwise isogenetic population can be different. To investigate such heterogeneity, experimental methods to zoom into the metabolism of individual cells are required. To this end, the autofluoresence of the redox cofactors NADH and NADPH offers great potential for single-cell dynamic NAD(P)H measurements. However, NAD(P)H excitation requires UV light, which can cause cell damage. In this work, we developed a method for time-lapse NAD(P)H imaging in single E. coli cells. Our method combines a setup with reduced background emission, UV-enhanced microscopy equipment and optimized exposure settings, overall generating acceptable NAD(P)H signals from single cells, with minimal negative effect on cell growth. Through different experiments, in which we perturb E. coli's redox metabolism, we demonstrated that the acquired fluorescence signal indeed corresponds to NAD(P)H. Using this new method, for the first time, we report that intracellular NAD(P)H levels oscillate along the bacterial cell division cycle. The developed method for dynamic measurement of NAD(P)H in single bacterial cells will be an important tool to zoom into metabolism of individual cells.

  18. An assessment of a film enhancement system for use in a radiation therapy department.

    PubMed

    Solowsky, E L; Reinstein, L E; Meek, A G

    1990-01-01

    The clinical uses of a radiotherapy film enhancement system are explored. The primary functions of the system are to improve the quality of poorly exposed simulator and portal films, and to perform comparisons between the two films to determine whether patient or block positioning errors are present. Other features include: the production of inexpensive, high quality hardcopy images of simulation films and initial portal films for chart documentation, the capacity to overlay lateral simulation films with sagittal MRI films to aid in field design, and a mode to zoom in on individual CT or MRI images and enlarge them for video display during chart rounds or instructional sessions. This commercially available system is comprised of a microcomputer, frame grabber, CCD camera with zoom lens, and a high-resolution thermal printer. The user-friendly software is menu driven and utilizes both keyboard and track ball to perform its functions. At the heart of the software is a very fast Adaptive Histogram Equalization (AHE) routine, which enhances and improves the readability of most portal films. The system has been evaluated for several disease sites, and its advantages and limitations will be presented.

  19. Characterization of the Failure Site Distribution in MIM Devices Using Zoomed Wavelet Analysis

    NASA Astrophysics Data System (ADS)

    Muñoz-Gorriz, J.; Monaghan, S.; Cherkaoui, K.; Suñé, J.; Hurley, P. K.; Miranda, E.

    2018-05-01

    The angular wavelet analysis is applied to the study of the spatial distribution of breakdown (BD) spots in Pt/HfO2/Pt capacitors with square and circular areas. The method is originally developed for rectangular areas, so a zoomed approach needs to be considered when the observation window does not coincide with the device area. The BD spots appear as a consequence of the application of electrical stress to the device. The stress generates defects within the dielectric film, a process that ends with the formation of a percolation path between the electrodes and the melting of the top metal layer because of the high release of energy. The BD spots have lateral sizes ranging from 1 μm to 3 μm and they appear as a point pattern that can be studied using spatial statistics methods. In this paper, we report the application of the angular wavelet method as a complementary tool for the analysis of the distribution of failure sites in large-area metal-insulator-metal (MIM) devices. The differences between considering a continuous or a discrete wavelet and the role played by the number of BD spots are also investigated.

  20. R-process Enrichment in Cosmological Zoom Simulation of a Milkyway Type Halo by Neutron Star Mergers; The Origin of the MP-R and CEMP-R Stars

    NASA Astrophysics Data System (ADS)

    Safarzadeh, Mohammadtaher; Scannapieco, Evan

    2018-06-01

    The history of r-process enrichment in our galaxy is modeled through a novel set of zoom cosmo- logical simulations on a MilkyWay type galaxy. r-process sources are assumed to be neutron star mergers with a distribution of natal kicks and merge time distribution. We model turbulent mixing to estimate the pristine gas fraction in each simulation cell which we use to determine the Pop III star formation with assigned Carbon rich ejecta when going off as SNe. We follow the formation of Carbon-Enhanced Metal-Poor (CEMP) stars and the statistics of different r-process enhanced class of stars. The simulation underpredict the frequency of CEMP/MP stars by a factor of 2-4. Likewise the MP-rI/MP and MP-rII/MP and CEMP-r/CEMP cumulative ratios are all under predicted by 1-2 orders of magnitude. Our results show that NS binaries by themselves fall too short to explain the observed frequency of r-process enhanced stars and other sources of r-process enrichment at high redshifts are needed to fill the gap.

  1. Optimization of Visual Information Presentation for Visual Prosthesis.

    PubMed

    Guo, Fei; Yang, Yuan; Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis.

  2. Optimization of Visual Information Presentation for Visual Prosthesis

    PubMed Central

    Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis. PMID:29731769

  3. Automatic source camera identification using the intrinsic lens radial distortion

    NASA Astrophysics Data System (ADS)

    Choi, Kai San; Lam, Edmund Y.; Wong, Kenneth K. Y.

    2006-11-01

    Source camera identification refers to the task of matching digital images with the cameras that are responsible for producing these images. This is an important task in image forensics, which in turn is a critical procedure in law enforcement. Unfortunately, few digital cameras are equipped with the capability of producing watermarks for this purpose. In this paper, we demonstrate that it is possible to achieve a high rate of accuracy in the identification by noting the intrinsic lens radial distortion of each camera. To reduce manufacturing cost, the majority of digital cameras are equipped with lenses having rather spherical surfaces, whose inherent radial distortions serve as unique fingerprints in the images. We extract, for each image, parameters from aberration measurements, which are then used to train and test a support vector machine classifier. We conduct extensive experiments to evaluate the success rate of a source camera identification with five cameras. The results show that this is a viable approach with high accuracy. Additionally, we also present results on how the error rates may change with images captured using various optical zoom levels, as zooming is commonly available in digital cameras.

  4. GIS application on modern Mexico

    NASA Astrophysics Data System (ADS)

    Prakash, Bharath

    This is a GIS based tool for showcasing the history of modern Mexico starting from the post-colonial era to the elections of 2012. The tool is developed using simple language and is flexible so as to allow for future enhancements. The application consists of numerous images and textual information, and also some links which can be used by primary and high school students to understand the history of modern Mexico, and also by tourists to look for all the international airports and United States of America consulates. This software depicts the aftermaths of the Colonial Era or the Spanish rule of Mexico. It covers various topics like the wars, politics, important personalities, drug cartels and violence. All these events are shown on GIS (Geographic information Science) maps. The software can be customized according to the user requirements and is developed using JAVA and GIS technology. The user interface is created using JAVA and MOJO which contributes to effective learning and understanding of the concepts with ease. Some of the user interface features provided in this tool includes zoom-in, zoom-out, legend editing, location identifier, print command, adding a layer and numerous menu items.

  5. TESTING OF TMR SAND MANTIS FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D; William Daugherty, W

    2007-06-12

    Screening tests of Sand Mantis candidate materials selected for erosion resistance have been completed. The results of this testing identified that over a relatively short period of operation (<1 hour), measurable erosion will occur in each of the candidate zoom tube materials given equal operating exposure. Additionally, this testing has shown that erosion of the rubber discharge hose directly downstream of the vehicle could be expected to limit the service life of the discharge hose. On the basis of these test results, SRNL recommends the following; {lg_bullet} redesign of critical system components (e.g., zoom tube, discharge hose) should be conductedmore » to improve system characteristics relative to erosion and capitalize on the results of this testing, {lg_bullet} continued efforts to deploy the Sand Mantis should include testing to better define and optimize operating parameters, and gain an understanding of system dynamics, {lg_bullet} discontinue wear testing with the selected materials pending redesign of critical system components (1st recommendation) and inclusion of other candidate materials. The final selection of additional candidate materials should be made following design changes, but might include a Stellite alloy or zirconia.« less

  6. Volunteers Help Decide Where to Point Mars Camera

    NASA Image and Video Library

    2015-07-22

    This series of images from NASA's Mars Reconnaissance Orbiter successively zooms into "spider" features -- or channels carved in the surface in radial patterns -- in the south polar region of Mars. In a new citizen-science project, volunteers will identify features like these using wide-scale images from the orbiter. Their input will then help mission planners decide where to point the orbiter's high-resolution camera for more detailed views of interesting terrain. Volunteers will start with images from the orbiter's Context Camera (CTX), which provides wide views of the Red Planet. The first two images in this series are from CTX; the top right image zooms into a portion of the image at left. The top right image highlights the geological spider features, which are carved into the terrain in the Martian spring when dry ice turns to gas. By identifying unusual features like these, volunteers will help the mission team choose targets for the orbiter's High Resolution Imaging Science Experiment (HiRISE) camera, which can reveal more detail than any other camera ever put into orbit around Mars. The final image is this series (bottom right) shows a HiRISE close-up of one of the spider features. http://photojournal.jpl.nasa.gov/catalog/PIA19823

  7. Seeing the big picture: Broadening attention relieves sadness and depressed mood.

    PubMed

    Gu, Li; Yang, Xueling; Li, Liman Man Wai; Zhou, Xinyue; Gao, Ding-Guo

    2017-08-01

    We examined whether the broadened attentional scope would affect people's sad or depressed mood with two experiments, enlightened by the meaning of "seeing the big picture" and the broaden-and-build model. Experiment 1 (n = 164) is a laboratory-based experiment, in which we manipulated the attentional scope by showing participants zoomed-out or zoomed-in scenes. In Experiment 2 (n = 44), we studied how depressed mood and positive and negative emotions were affected when participants watched distant versus proximal scenes for eight weeks in real life. Healthy participants in Experiment 1, who were induced to feel sad, could return to the baseline mood after having the broadened attention task but not after having the narrowed attention task, which indicated that immediate attention broadening manipulation could function as antidotes for the lingering effects of induced negative emotions. Participants with depressed mood in Experiment 2 showed reduced depressed mood, increased positive affect, and decreased negative affect after receiving attention broadening training compared to those receiving attention narrowing training. Our findings suggest a robust role of broadened attentional scope in relieving negative emotions and even mildly depressed mood in the long run. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  8. Galactic Angular Momentum in Cosmological Zoom-in Simulations. I. Disk and Bulge Components and the Galaxy-Halo Connection

    NASA Astrophysics Data System (ADS)

    Sokołowska, Aleksandra; Capelo, Pedro R.; Fall, S. Michael; Mayer, Lucio; Shen, Sijing; Bonoli, Silvia

    2017-02-01

    We investigate the angular momentum evolution of four disk galaxies residing in Milky-Way-sized halos formed in cosmological zoom-in simulations with various sub-grid physics and merging histories. We decompose these galaxies, kinematically and photometrically, into their disk and bulge components. The simulated galaxies and their components lie on the observed sequences in the j *-M * diagram, relating the specific angular momentum and mass of the stellar component. We find that galaxies in low-density environments follow the relation {j}* \\propto {M}* α past major mergers, with α ˜ 0.6 in the case of strong feedback, when bulge-to-disk ratios are relatively constant, and α ˜ 1.4 in the other cases, when secular processes operate on shorter timescales. We compute the retention factors (I.e., the ratio of the specific angular momenta of stars and dark matter) for both disks and bulges and show that they vary relatively slowly after averaging over numerous but brief fluctuations. For disks, the retention factors are usually close to unity, while for bulges, they are a few times smaller. Our simulations therefore indicate that galaxies and their halos grow in a quasi-homologous way.

  9. Assessment of directionality performances: comparison between Freedom and CP810 sound processors.

    PubMed

    Razza, Sergio; Albanese, Greta; Ermoli, Lucilla; Zaccone, Monica; Cristofari, Eliana

    2013-10-01

    To compare speech recognition in noise for the Nucleus Freedom and CP810 sound processors using different directional settings among those available in the SmartSound portfolio. Single-subject, repeated measures study. Tertiary care referral center. Thirty-one monoaurally and binaurally implanted subjects (24 children and 7 adults) were enrolled. They were all experienced Nucleus Freedom sound processor users and achieved a 100% open set word recognition score in quiet listening conditions. Each patient was fitted with the Freedom and the CP810 processor. The program setting incorporated Adaptive Dynamic Range Optimization (ADRO) and adopted the directional algorithm BEAM (both devices) and ZOOM (only on CP810). Speech reception threshold (SRT) was assessed in a free-field layout, with disyllabic word list and interfering multilevel babble noise in the 3 different pre-processing configurations. On average, CP810 improved significantly patients' SRTs as compared to Freedom SP after 1 hour of use. Instead, no significant difference was observed in patients' SRT between the BEAM and the ZOOM algorithm fitted in the CP810 processor. The results suggest that hardware developments achieved in the design of CP810 allow an immediate and relevant directional advantage as compared to the previous-generation Freedom device.

  10. Jupiter Polar Winds Movie Blowup

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Persistent polar storms and zonal winds on Jupiter can be seen in this magnified quadrant from a movie projecting images from NASA's Cassini spacecraft as if the viewer were looking down at Jupiter's north pole and the planet were flattened.

    The sequence covers 70 days, from October 1 to December 9, 2000. Cassini's narrow-angle camera captured the images of Jupiter's atmosphere in the near-infrared region of the spectrum.

    Like the accompanying full-circle movie of polar winds, this zoomed-inversion shows that the polar region has coherent flows, despite its chaotic, mottled appearance. There are thousands of spots, each an active storm similar in size to the largest storms on Earth. The spots occasionally change latitude or merge with each other, but usually they last for the entire 70 days. Until now, the lifetime of those storms was unknown.

    The mystery of Jupiter's weather is why the storms last so long. Storms on Earth last for a week before they break up and are replaced by other storms. This movie heightens the mystery because it shows long-lived storms at the highest latitudes, where the weather patterns are more disorganized than at low latitudes.

    Cassini collected images of Jupiter for months before and after it passed the planet on December 30, 2000. Six images or more of the planet in each of several spectral filters were taken at evenly spaced intervals over the course of Jupiter's 10-hour rotation period. The entire sequence was repeated generally every other Jupiter rotation, yielding views of every sector of the planet at least once every 20 hours.

    The images used for the movie shown here were taken every 20 hours through a filter centered at a wavelength of 756 nanometers, where there are almost no absorptions in the planet's atmosphere. Images from each rotation were assembled first into a cylindrical map. The 84 resulting cylindrical maps, spanning 70 Earth days or 168 Jupiter rotations, were transformed to polar stereographic projections, making a map centered on the north pole. This clip shows detail by zooming in on one quadrant of the full-circle polar projection. Jupiter's alternating eastward and westward jet streams flow in concentric rings around the pole.

    For more information, see the Cassini Project home page, http://www.jpl.nasa.gov/cassini/ and the Cassini Imaging Team home page, http://ciclops.lpl.arizona.edu/ciclops/ .

    Cassini is a cooperative project of NASA, the European Space Agency and the Italian Space Agency. The Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Cassini mission for NASA's Office of Space Science, Washington, D.C.

  11. Temperatures and Water Levels at Tanana Flats Monitoring Stations

    DTIC Science & Technology

    2008-04-01

    a Druck pressure trans- ducer near the bottom. In response to this drawdown, the initial record showed a water level of 1.13 m on 1 April 2005, which...gradually increased to 1.68 m on 8 April. Freezing of the sensor on 9–10 April ended the reli- able water level record. A pair of replacement Drucks ...again, and a new Druck was installed to replace those that had been frozen. With rising tem- peratures at the bottom of the well, an injection of 400 g

  12. Research notes : monitoring the health of bridges.

    DOT National Transportation Integrated Search

    2006-02-01

    Research at Oregon State University has provided ODOT with better analytical tools for determining the safe load capacity of the cracked bridges. ODOT personnel now know that cracks alone do not necessarily mean that a bridge must be replaced. Method...

  13. Bridge health monitoring metrics : updating the bridge deficiency algorithm.

    DOT National Transportation Integrated Search

    2009-10-01

    As part of its bridge management system, the Alabama Department of Transportation (ALDOT) must decide how best to spend its bridge replacement funds. In making these decisions, ALDOT managers currently use a deficiency algorithm to rank bridges that ...

  14. Continuous Glucose Monitoring

    MedlinePlus

    ... costs will be covered. What is an artificial pancreas? A CGM is one part of the “artificial pancreas” systems that are beginning to reach people with ... has played an important role in developing artificial pancreas technology. An artificial pancreas replaces manual blood glucose ...

  15. Determination of Section 404 Permit and Habitat Mitigation Requirements

    DOT National Transportation Integrated Search

    2012-09-01

    The Arizona Department of Transportation (ADOT) is committed to developing habitat, mitigation, : monitoring, and maintenance plans that replace the loss of the functions and values of an area and : are self-sustaining, thereby providing long-term co...

  16. Feasibility Study of a Rotorcraft Health and Usage Monitoring System (HUMS): Usage and Structural Life Monitoring Evaluation

    NASA Technical Reports Server (NTRS)

    Dickson, B.; Cronkhite, J.; Bielefeld, S.; Killian, L.; Hayden, R.

    1996-01-01

    The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FIS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques.

  17. Event-Driven Messaging for Offline Data Quality Monitoring at ATLAS

    NASA Astrophysics Data System (ADS)

    Onyisi, Peter

    2015-12-01

    During LHC Run 1, the information flow through the offline data quality monitoring in ATLAS relied heavily on chains of processes polling each other's outputs for handshaking purposes. This resulted in a fragile architecture with many possible points of failure and an inability to monitor the overall state of the distributed system. We report on the status of a project undertaken during the LHC shutdown to replace the ad hoc synchronization methods with a uniform message queue system. This enables the use of standard protocols to connect processes on multiple hosts; reliable transmission of messages between possibly unreliable programs; easy monitoring of the information flow; and the removal of inefficient polling-based communication.

  18. History of technology in the intensive care unit.

    PubMed

    Puri, Nitin; Puri, Vinod; Dellinger, R P

    2009-01-01

    Critical care medicine is a young specialty and since its inception has been heavily reliant upon technology. Invasive monitoring has its humble beginnings in the continuous monitoring of heart rate and rhythm. From the development of right heart catheterization to the adaption of the echocardiogram for use in shock, intensivists have used technology to monitor hemodynamics. The care of the critically ill has been buoyed by investigators who sought to offer renal replacement therapy to unstable patients and worked to improve the monitoring of oxygen saturation. The evolution of mechanical ventilation for the critically ill embodies innumerable technological advances. More recently, critical care has insisted upon rigorous testing and cost-benefit analysis of technological advances.

  19. SPIDER: Next Generation Chip Scale Imaging Sensor

    NASA Astrophysics Data System (ADS)

    Duncan, Alan; Kendrick, Rick; Thurman, Sam; Wuchenich, Danielle; Scott, Ryan P.; Yoo, S. J. B.; Su, Tiehui; Yu, Runxiang; Ogden, Chad; Proiett, Roberto

    The LM Advanced Technology Center and UC Davis are developing an Electro-Optical (EO) imaging sensor called SPIDER (Segmented Planar Imaging Detector for Electro-optical Reconnaissance) that provides a 10x to 100x size, weight, and power (SWaP) reduction alternative to the traditional bulky optical telescope and focal plane detector array. The substantial reductions in SWaP would reduce cost and/or provide higher resolution by enabling a larger aperture imager in a constrained volume. The SPIDER concept consists of thousands of direct detection white-light interferometers densely packed onto Photonic Integrated Circuits (PICs) to measure the amplitude and phase of the visibility function at spatial frequencies that span the full synthetic aperture. In other words, SPIDER would sample the object being imaged in the Fourier domain (i.e., spatial frequency domain), and then digitally reconstruct an image. The conventional approach for imaging interferometers requires complex mechanical delay lines to form the interference fringes. This results in designs that are not traceable to more than a few simultaneous spatial frequency measurements. SPIDER seeks to achieve this traceability by employing micron-=scale optical waveguides and nanophotonic structures fabricated on a PIC with micron-scale packing density to form the necessary interferometers. Prior LM IRAD and DARPA/NASA CRAD-funded SPIDER risk reduction experiments, design trades, and simulations have matured the SPIDER imager concept to a TRL 3 level. Current funding under the DARPA SPIDER Zoom program is maturing the underlying PIC technology for SPIDER to the TRL 4 level. This is done by developing and fabricating a second-generation PIC that is fully traceable to the multiple layers and low-power phase modulators required for higher-dimension waveguide arrays that are needed for higher field-of-view sensors. Our project also seeks to extend the SPIDER concept to add a zoom capability that would provide simultaneous low-resolution, large field-of-view and steerable high-resolution, narrow field-of-view imaging modes. A proof of concept demo is being designed to validate this capability. Finally, data collected by this project would be used to benchmark and increase the fidelity of our SPIDER image simulations and enhance our ability to predict the performance of existing and future SPIDER sensor design variations. These designs and their associated performance characteristics could then be evaluated as candidates for future mission opportunities to identify specific transition paths. This paper provides an overview of performance data on the first-generation PIC for SPIDER developed under DARPA SeeMe program funding. We provide a design description of the SPICER Zoom imaging sensor and the second-generation PIC (high- and low-resolution versions) currently under development on the DARPA SPIDER Zoom effort. Results of performance simulations and design trades are presented. Unique low-cost payload applications for future SSA missions are also discussed.

  20. Final Scientific Report: A Scalable Development Environment for Peta-Scale Computing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karbach, Carsten; Frings, Wolfgang

    2013-02-22

    This document is the final scientific report of the project DE-SC000120 (A scalable Development Environment for Peta-Scale Computing). The objective of this project is the extension of the Parallel Tools Platform (PTP) for applying it to peta-scale systems. PTP is an integrated development environment for parallel applications. It comprises code analysis, performance tuning, parallel debugging and system monitoring. The contribution of the Juelich Supercomputing Centre (JSC) aims to provide a scalable solution for system monitoring of supercomputers. This includes the development of a new communication protocol for exchanging status data between the target remote system and the client running PTP.more » The communication has to work for high latency. PTP needs to be implemented robustly and should hide the complexity of the supercomputer's architecture in order to provide a transparent access to various remote systems via a uniform user interface. This simplifies the porting of applications to different systems, because PTP functions as abstraction layer between parallel application developer and compute resources. The common requirement for all PTP components is that they have to interact with the remote supercomputer. E.g. applications are built remotely and performance tools are attached to job submissions and their output data resides on the remote system. Status data has to be collected by evaluating outputs of the remote job scheduler and the parallel debugger needs to control an application executed on the supercomputer. The challenge is to provide this functionality for peta-scale systems in real-time. The client server architecture of the established monitoring application LLview, developed by the JSC, can be applied to PTP's system monitoring. LLview provides a well-arranged overview of the supercomputer's current status. A set of statistics, a list of running and queued jobs as well as a node display mapping running jobs to their compute resources form the user display of LLview. These monitoring features have to be integrated into the development environment. Besides showing the current status PTP's monitoring also needs to allow for submitting and canceling user jobs. Monitoring peta-scale systems especially deals with presenting the large amount of status data in a useful manner. Users require to select arbitrary levels of detail. The monitoring views have to provide a quick overview of the system state, but also need to allow for zooming into specific parts of the system, into which the user is interested in. At present, the major batch systems running on supercomputers are PBS, TORQUE, ALPS and LoadLeveler, which have to be supported by both the monitoring and the job controlling component. Finally, PTP needs to be designed as generic as possible, so that it can be extended for future batch systems.« less

  1. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belle R. Upadhyaya; J. Wesley Hines

    2004-09-27

    Integrity monitoring and flaw diagnostics of flat beams and tubular structures was investigated in this research task using guided acoustic signals. A piezo-sensor suite was deployed to activate and collect Lamb wave signals that propagate along metallic specimens. The dispersion curves of Lamb waves along plate and tubular structures are generated through numerical analysis. Several advanced techniques were explored to extract representative features from acoustic time series. Among them, the Hilbert-Huang transform (HHT) is a recently developed technique for the analysis of non-linear and transient signals. A moving window method was introduced to generate the local peak characters from acousticmore » time series, and a zooming window technique was developed to localize the structural flaws. The time-frequency analysis and pattern recognition techniques were combined for classifying structural defects in brass tubes. Several types of flaws in brass tubes were tested, both in the air and in water. The techniques also proved to be effective under background/process noise. A detailed theoretical analysis of Lamb wave propagation was performed and simulations were carried out using the finite element software system ABAQUS. This analytical study confirmed the behavior of the acoustic signals acquired from the experimental studies. The report presents the background the analysis of acoustic signals acquired from piezo-electric transducers for structural defect monitoring. A comparison of the use of time-frequency techniques, including the Hilbert-Huang transform, is presented. The report presents the theoretical study of Lamb wave propagation in flat beams and tubular structures, and the need for mode separation in order to effectively perform defect diagnosis. The results of an extensive experimental study of detection, location, and isolation of structural defects in flat aluminum beams and brass tubes are presented. The results of this research show the feasibility of on-line monitoring of small structural flaws by the use of transient and nonlinear acoustic signal analysis, and its implementation by the proper design of a piezo-electric transducer suite.« less

  2. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland.

    PubMed

    Checketts, M R; Alladi, R; Ferguson, K; Gemmell, L; Handy, J M; Klein, A A; Love, N J; Misra, U; Morris, C; Nathanson, M H; Rodney, G E; Verma, R; Pandit, J J

    2016-01-01

    This guideline updates and replaces the 4th edition of the AAGBI Standards of Monitoring published in 2007. The aim of this document is to provide guidance on the minimum standards for physiological monitoring of any patient undergoing anaesthesia or sedation under the care of an anaesthetist. The recommendations are primarily aimed at anaesthetists practising in the United Kingdom and Ireland. Minimum standards for monitoring patients during anaesthesia and in the recovery phase are included. There is also guidance on monitoring patients undergoing sedation and also during transfer of anaesthetised or sedated patients. There are new sections discussing the role of monitoring depth of anaesthesia, neuromuscular blockade and cardiac output. The indications for end-tidal carbon dioxide monitoring have been updated. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.

  3. Nocturnal hypoglycemia identified by a continuous glucose monitoring system in patients with primary adrenal insufficiency (Addison's Disease).

    PubMed

    Meyer, Gesine; Hackemann, Annika; Reusch, Juergen; Badenhoop, Klaus

    2012-05-01

    Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3-5 days. In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects.

  4. Optimization of wireless Bluetooth sensor systems.

    PubMed

    Lonnblad, J; Castano, J; Ekstrom, M; Linden, M; Backlund, Y

    2004-01-01

    Within this study, three different Bluetooth sensor systems, replacing cables for transmission of biomedical sensor data, have been designed and evaluated. The three sensor architectures are built on 1-, 2- and 3-chip solutions and depending on the monitoring situation and signal character, different solutions are optimal. Essential parameters for all systems have been low physical weight and small size, resistance to interference and interoperability with other technologies as global- or local networks, PC's and mobile phones. Two different biomedical input signals, ECG and PPG (photoplethysmography), have been used to evaluate the three solutions. The study shows that it is possibly to continuously transmit an analogue signal. At low sampling rates and slowly varying parameters, as monitoring the heart rate with PPG, the 1-chip solution is the most suitable, offering low power consumption and thus a longer battery lifetime or a smaller battery, minimizing the weight of the sensor system. On the other hand, when a higher sampling rate is required, as an ECG, the 3-chip architecture, with a FPGA or micro-controller, offers the best solution and performance. Our conclusion is that Bluetooth might be useful in replacing cables of medical monitoring systems.

  5. KCBX Letter to EPA - Aug. 27, 2014

    EPA Pesticide Factsheets

    A quality control check revealed that temperature data for June 26-Aug. 6, 2014 from the meteorological monitor at NT-NW was not accurate. KCBX replaced the invalidated data with hourly ambient temperature data from other equipment and sent updated files.

  6. Next generation safety performance monitoring at signalized intersections using connected vehicle technology.

    DOT National Transportation Integrated Search

    2014-08-01

    Crash-based safety evaluation is often hampered by randomness, lack of timeliness, and rarity of crash : occurrences. This is particularly the case for technology-driven safety improvement projects that are : frequently updated or replaced by newer o...

  7. Help Kids Stay Safe on the Playground | DoDLive

    Science.gov Websites

    . One day, as I zoomed past another kid on this imaginary rink, I lost my balance, hit the ice face -first and shot like a hockey puck across its slippery surface before slamming into a chain link fence one else knows I have a fake front tooth, but I am reminded every day of that playground injury many

  8. The Secret Lives of Galaxies

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The ground-based image in visible light locates the hub imaged with the Hubble Space Telescope. This barred galaxy feeds material into its hub, igniting star birth. The Hubble NICMOS instrument penetrates beneath the dust to reveal clusters of young stars. Footage shows ground-based, WFPC2, and NICMOS images of NGS 1365. An animation of a large spiral galaxy zooms from the edge to the galactic bulge.

  9. Big Skills for the Common Core: Literacy Strategies for the 6-12 Classroom

    ERIC Educational Resources Information Center

    Benjamin, Amy; Hugelmeyer, Michael

    2013-01-01

    Zoom in on the academic skills students are required to learn in reading, writing, speaking/listening, and language! This book cuts through all of the Common Core jargon and gets right to the heart of what students need to learn now. "Big Skills for the Common Core" is packed with engaging strategies you can use immediately to improve your…

  10. Zooming in on Life Events: Is Hedonic Adaptation Sensitive to the Temporal Distance from the Event?

    ERIC Educational Resources Information Center

    Uglanova, Ekaterina A.; Staudinger, Ursula M.

    2013-01-01

    This paper analyzed the effect of major positive and negative life events (marriage, divorce, birth of child, widowhood, and unemployment) on life satisfaction. For the first time, this study estimated the effects of life events not with a precision of 12 months but of 3 months. Specifically, two questions were addressed: (1) Does the precision of…

  11. Effects of Selected Filmic Coding Elements of TV on the Development of the Euclidean Concepts of Horizontality and Verticality in Adolescents.

    ERIC Educational Resources Information Center

    Lynch, Beth Eloise

    This study was conducted to determine whether the filmic coding elements of split screen, slow motion, generated line cues, the zoom of a camera, and rotation could aid in the development of the Euclidean space concepts of horizontality and verticality, and to explore presence and development of spatial skills involving these two concepts in…

  12. Zigging and Zooming All over the Place: Young Children's Meaning Making and Movement in the Museum

    ERIC Educational Resources Information Center

    Hackett, Abigail

    2014-01-01

    This article draws attention to the walking and running of young children as a key element of their multimodal communicative practices. In addition, the article argues that the walking and running of young children can be seen as a place-making activity, acknowledging the power of young children to create meaning in their world. Drawing on…

  13. View west within the periphery of the load dispatch model ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west within the periphery of the load dispatch model board, operator's console is at lower center and button board is at lower right of the photograph; section of model board shown covers substation from Perryman (left) to Frankford (right); instruments at right center of photograph formerly monitored energy usage and were replaced by computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  14. Use of a color CMOS camera as a colorimeter

    NASA Astrophysics Data System (ADS)

    Dallas, William J.; Roehrig, Hans; Redford, Gary R.

    2006-08-01

    In radiology diagnosis, film is being quickly replaced by computer monitors as the display medium for all imaging modalities. Increasingly, these monitors are color instead of monochrome. It is important to have instruments available to characterize the display devices in order to guarantee reproducible presentation of image material. We are developing an imaging colorimeter based on a commercially available color digital camera. The camera uses a sensor that has co-located pixels in all three primary colors.

  15. Novel wireless health monitor with acupuncture bio-potentials obtained by using a replaceable salt-water-wetted foam-rubber cushions on RFID-tag.

    PubMed

    Lin, Jium-Ming; Lu, Hung-Han; Lin, Cheng-Hung

    2014-01-01

    This paper proposes a bio-potential measurement apparatus including a wireless device for transmitting acupuncture bio-potential information to a remote control station for health conditions analysis and monitor. The key technology of this system is to make replaceable foam-rubber cushions, double-side conducting tapes, chip and antenna on the radio frequency identification (RFID) tag. The foam-rubber cushions can be wetted with salt-water and contact with the acupuncture points to reduce contact resistance. Besides, the double-side conducting tapes are applied to fix foam-rubber cushions. Thus, one can peel the used cushions or tapes away and supply new ones quickly. Since the tag is a flexible plastic substrate, it is easy to deploy on the skin. Besides, the amplifier made by CMOS technology on RFID chip could amplify the signals to improve S/N ratio and impedance matching. Thus, cloud server can wirelessly monitor the health conditions. An example shows that the proposed system can be used as a wireless health condition monitor, the numerical method and the criteria are given to analyze eleven bio-potentials for the important acupunctures of eleven meridians on a person's hands and legs. Then a professional doctor can know the performance of an individual and the cross-linking effects of the organs.

  16. Engineering the Ideal Gigapixel Image Viewer

    NASA Astrophysics Data System (ADS)

    Perpeet, D. Wassenberg, J.

    2011-09-01

    Despite improvements in automatic processing, analysts are still faced with the task of evaluating gigapixel-scale mosaics or images acquired by telescopes such as Pan-STARRS. Displaying such images in ‘ideal’ form is a major challenge even today, and the amount of data will only increase as sensor resolutions improve. In our opinion, the ideal viewer has several key characteristics. Lossless display - down to individual pixels - ensures all information can be extracted from the image. Support for all relevant pixel formats (integer or floating point) allows displaying data from different sensors. Smooth zooming and panning in the high-resolution data enables rapid screening and navigation in the image. High responsiveness to input commands avoids frustrating delays. Instantaneous image enhancement, e.g. contrast adjustment and image channel selection, helps with analysis tasks. Modest system requirements allow viewing on regular workstation computers or even laptops. To the best of our knowledge, no such software product is currently available. Meeting these goals requires addressing certain realities of current computer architectures. GPU hardware accelerates rendering and allows smooth zooming without high CPU load. Programmable GPU shaders enable instant channel selection and contrast adjustment without any perceptible slowdown or changes to the input data. Relatively low disk transfer speeds suggest the use of compression to decrease the amount of data to transfer. Asynchronous I/O allows decompressing while waiting for previous I/O operations to complete. The slow seek times of magnetic disks motivate optimizing the order of the data on disk. Vectorization and parallelization allow significant increases in computational capacity. Limited memory requires streaming and caching of image regions. We develop a viewer that takes the above issues into account. Its awareness of the computer architecture enables previously unattainable features such as smooth zooming and image enhancement within high-resolution data. We describe our implementation, disclosing its novel file format and lossless image codec whose decompression is faster than copying the raw data in memory. Both provide crucial performance boosts compared to conventional approaches. Usability tests demonstrate the suitability of our viewer for rapid analysis of large SAR datasets, multispectral satellite imagery and mosaics.

  17. Measurement of Salivary Cortisone to Assess the Adequacy of Hydrocortisone Replacement.

    PubMed

    Raff, Hershel

    2016-04-01

    This Commentary discusses the study of Debono et al (19) and focuses on the potential use of multiple salivary cortisone measurements to evaluate the adequacy of hydrocortisone replacement therapy. Salivary cortisone, typically measured using liquid chromatography-tandem mass spectrometry, accurately reflects plasma free cortisol because of the expression of 11-β -hydroxysteroid dehydrogenase in the salivary gland. Debono et al showed that multiple, sequential salivary cortisone measurements obtained over a 12-hour period correlated with plasma free cortisol in subjects receiving intravenous or oral hydrocortisone (authentic cortisol). Hopefully, these studies will lead to a simplified protocol with fewer samples for the measurement of salivary cortisone that can reliably assess the adequacy of hydrocortisone replacement in patients with adrenal insufficiency. This protocol has to be cost-effective and be feasible to obtain timed salivary samples accurately at home. It would be a significant advance to be able to monitor hydrocortisone replacement therapy with as few as one or two salivary cortisone measurements.

  18. Comparison of an in-helmet temperature monitor system to rectal temperature during exercise.

    PubMed

    Wickwire, P Jason; Buresh, Robert J; Tis, Laurie L; Collins, Mitchell A; Jacobs, Robert D; Bell, Marla M

    2012-01-01

    Body temperature monitoring is crucial in helping to decrease the amount and severity of heat illnesses; however, a practical method of monitoring temperature is lacking. In response to the lack of a practical method of monitoring the temperature of athletes, Hothead Technologies developed a device (HOT), which continuously monitors an athlete's fluctuations in body temperature. HOT measures forehead temperature inside helmets. The purpose of this study was to compare HOT against rectal temperature (Trec). Male volunteers (n = 29, age = 23.5 ± 4.5 years, weight = 83.8 ± 10.4 kg, height = 180.1 ± 5.8 cm, body fat = 12.3 ± 4.5%) exercised on a treadmill at an intensity of 60-75% heart rate reserve (HRR) (wet bulb globe temperature [WBGT] = 28.7° C) until Trec reached 38.7° C. The correlation between Trec and HOT was 0.801 (R = 0.64, standard error of the estimate (SEE) = 0.25, p = 0.00). One reason for this relatively high correlation is the microclimate that HOT is monitoring. HOT is not affected by the external climate greatly because of its location in the helmet. Therefore, factors such as evaporation do not alter HOT temperature to a great degree. HOT was compared with Trec in a controlled setting, and the exercise used in this study was moderate aerobic exercise, very unlike that used in football. In a controlled laboratory setting, the relationship between HOT and Trec showed favorable correlations. However, in applied settings, helmets are repeatedly removed and replaced forcing HOT to equilibrate to forehead temperature every time the helmet is replaced. Therefore, future studies are needed to mimic how HOT will be used in field situations.

  19. 40 CFR 270.4 - Effect of a permit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... regarding leak detection systems for new and replacement surface impoundment, waste pile, and landfill units, and lateral expansions of surface impoundment, waste pile, and landfill units. The leak detection system requirements include double liners, CQA programs, monitoring, action leakage rates, and response...

  20. Handling Rapid Growth.

    ERIC Educational Resources Information Center

    Scheideman, Dale; Dufresne, Ray

    2001-01-01

    Nevada's Clark County, the fastest growing school district in the nation, uses a life-cycle facilities management approach that monitors the individual components of each building on a database. The district's 10-year building program is addressing facilities infrastructure renewal, deferred maintenance, replacement, and new school construction.…

  1. Soil Moisture Sensing

    USDA-ARS?s Scientific Manuscript database

    Soil moisture monitoring can be useful as an irrigation management tool for both landscapes and agriculture, sometimes replacing an evapotranspiration (ET) based approach or as a useful check on ET based approaches since the latter tend to drift off target over time. All moisture sensors, also known...

  2. Construction and performance monitoring of various asphalt mixes in Illinois : 2016 interim report.

    DOT National Transportation Integrated Search

    2017-02-01

    A series of five experimental projects were constructed to better determine the life-cycle cost and performance of pavement overlays using various levels of asphalt binder replacement (ABR) from use of reclaimed asphalt pavement (RAP), recycled aspha...

  3. Biomonitoring our streams

    USGS Publications Warehouse

    Byl, Thomas Duane; Smith, George F.

    1994-01-01

    Biomonitoring is often used to enhance or replace chemical monitoring when evaluating water quality in our streams. This report is intended to introduce the theories behind biomonitoring and some of the techniques used in a biomonitoring study. It also lists some of the advantages and limitations of biomonitoring.

  4. Interacting hands: the role of attention for the joint Simon effect

    PubMed Central

    Liepelt, Roman

    2014-01-01

    Recent research in monkeys and humans has shown that the presence of the hands near an object enhances spatial processing for objects presented near the hand. This study aimed to test the effect of hand position on the joint Simon effect. In Experiment 1, two human co-actors shared a Simon task while placing their response hands either near the objects appearing on the monitor or away from the monitor. Experiment 2 varied each co-actor’s hand position independently. Experiment 3 tested whether enhanced spatial processing for objects presented near the hand is obtained when replacing one of the two co-actors by a non-human event-producing rubber hand. Experiment 1 provided evidence for a Simon effect. Hand position significantly modulated the size of the Simon effect in the joint Simon task showing an increased Simon effect when the hands of both actors were located near the objects on the monitor, than when they were located away from the monitor. Experiment 2 replicated this finding showing an increased Simon effect when the actor’s hand was located near the objects on the monitor, but only when the co-actor also produced action events in spatial reference. A similar hand position effect was observed in Experiment 3 when a non-human rubber hand replaced the human co-actor. These findings suggest that external action events that are produced in spatial reference bias the distribution of attention to the area near the hand. This strengthens the weight of the spatial response codes (referential coding) and hence increases the joint Simon effect. PMID:25566140

  5. Cognitive Control Reflects Context Monitoring, Not Motoric Stopping, in Response Inhibition

    PubMed Central

    Chatham, Christopher H.; Claus, Eric D.; Kim, Albert; Curran, Tim; Banich, Marie T.; Munakata, Yuko

    2012-01-01

    The inhibition of unwanted behaviors is considered an effortful and controlled ability. However, inhibition also requires the detection of contexts indicating that old behaviors may be inappropriate – in other words, inhibition requires the ability to monitor context in the service of goals, which we refer to as context-monitoring. Using behavioral, neuroimaging, electrophysiological and computational approaches, we tested whether motoric stopping per se is the cognitively-controlled process supporting response inhibition, or whether context-monitoring may fill this role. Our results demonstrate that inhibition does not require control mechanisms beyond those involved in context-monitoring, and that such control mechanisms are the same regardless of stopping demands. These results challenge dominant accounts of inhibitory control, which posit that motoric stopping is the cognitively-controlled process of response inhibition, and clarify emerging debates on the frontal substrates of response inhibition by replacing the centrality of controlled mechanisms for motoric stopping with context-monitoring. PMID:22384038

  6. A Fully Redundant On-Line Mass Spectrometer System Used to Monitor Cryogenic Fuel Leaks on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Griffin, Timothy P.; Naylor, Guy R.; Haskell, William D.; Breznik, Greg S.; Mizell, Carolyn A.; Helms, William R.; Voska, N. (Technical Monitor)

    2002-01-01

    An on-line gas monitoring system was developed to replace the older systems used to monitor for cryogenic leaks on the Space Shuttles before launch. The system uses a mass spectrometer to monitor multiple locations in the process, which allows the system to monitor all gas constituents of interest in a nearly simultaneous manner. The system is fully redundant and meets all requirements for ground support equipment (GSE). This includes ruggedness to withstand launch on the Mobile Launcher Platform (MLP), ease of operation, and minimal operator intervention. The system can be fully automated so that an operator is notified when an unusual situation or fault is detected. User inputs are through personal computer using mouse and keyboard commands. The graphical user for detecting cryogenic leaks, many other gas constituents could be monitored using the Hazardous Gas Detection System (HGDS) 2000.

  7. Life support subsystem monitoring instrumentation

    NASA Technical Reports Server (NTRS)

    Powell, J. D.; Kostell, G. D.

    1974-01-01

    The recognition of the need for instrumentation in manned spacecraft life-support subsystems has increased significantly over the past several years. Of the required control and monitoring instrumentation, this paper will focus on the monitoring instrumentation as applied to life-support subsystems. The initial approach used independent sensors, independent sensor signal conditioning circuitry, and independent logic circuitry to provide shutdown protection only. This monitoring system was replaced with a coordinated series of printed circuit cards, each of which contains all the electronics to service one sensor and provide performance trend information, fault detection and isolation information, and shutdown protection. Finally, a review of sensor and instrumentation problems is presented, and the requirement for sensors with built-in signal conditioning and provisions for in situ calibration is discussed.

  8. Detecting Vital Signs with Wearable Wireless Sensors

    PubMed Central

    Yilmaz, Tuba; Foster, Robert; Hao, Yang

    2010-01-01

    The emergence of wireless technologies and advancements in on-body sensor design can enable change in the conventional health-care system, replacing it with wearable health-care systems, centred on the individual. Wearable monitoring systems can provide continuous physiological data, as well as better information regarding the general health of individuals. Thus, such vital-sign monitoring systems will reduce health-care costs by disease prevention and enhance the quality of life with disease management. In this paper, recent progress in non-invasive monitoring technologies for chronic disease management is reviewed. In particular, devices and techniques for monitoring blood pressure, blood glucose levels, cardiac activity and respiratory activity are discussed; in addition, on-body propagation issues for multiple sensors are presented. PMID:22163501

  9. Plasma, salivary and urinary cortisol levels following physiological and stress doses of hydrocortisone in normal volunteers.

    PubMed

    Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J

    2014-11-26

    Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P <0.0001, correlation coefficient between 0.61 and 0.94). There was no difference in CBG levels across the sampling period. An oral dose of hydrocortisone 20 mg is supraphysiological for routine maintenance, while stress doses above 50 mg 6-hourly would rarely be necessary in managing acute illness. Salivary cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.

  10. Apparatus for monitoring tritium in tritium contaminating environments using a modified Kanne chamber

    DOEpatents

    Anderson, David F.

    1984-01-01

    A conventional Kanne tritium monitor has been redesigned to reduce its sensitivity to such contaminants as tritiated water vapor and tritiated oil. The high voltage electrode has been replaced by a wire cylinder and the collector electrode has been reduced in diameter. The area sensitive to contamination has thereby been reduced by about a factor of forty while the overall apparatus sensitivity and operation has not been affected. The design allows for in situ decontamination of the chambers, if necessary.

  11. Apparatus for monitoring tritium in tritium-contaminating environments using a modified Kanne chamber

    DOEpatents

    Anderson, D.F.

    1981-01-27

    A conventional Kanne tritium monitor has been redesigned to reduce its sensitivity to such contaminants as tritiated water vapor and tritiated oil. The high voltage electrode has been replaced by a wire cylinder and the collector electrode has been reduced in diameter. The area sensitive to contamination has thereby been reduced by about a factor of forty while the overall apparatus sensitivity and operation has not been affected. The design allows for in situ decontamination of the chambers, if necessary.

  12. Gear Damage Detection Integrating Oil Debris and Vibration Measurement Technologies Developed

    NASA Technical Reports Server (NTRS)

    Gyekeyeski, Andrew L.; Sawicki, Jerzy T.

    2001-01-01

    The development of highly reliable health-monitoring systems is one technology area recommended for reducing the number of helicopter accidents. Helicopter transmission diagnostics are an important part of a helicopter health-monitoring system because helicopters depend on the power train for propulsion, lift, and flight maneuvering. One technique currently being tested for increasing the reliability and decreasing the false alarm rate of current transmission diagnostic tools is the replacement of simple single-sensor limits with multisensor systems integrating different measurement technologies.

  13. In vitro and in vivo documentation of quantum dots labeled Trypanosoma cruzi--Rhodnius prolixus interaction using confocal microscopy.

    PubMed

    Feder, Denise; Gomes, Suzete A O; de Thomaz, André A; Almeida, Diogo B; Faustino, Wagner M; Fontes, Adriana; Stahl, Cecília V; Santos-Mallet, Jacenir R; Cesar, Carlos L

    2009-12-01

    Semiconductor quantum dots (QDs) are highly fluorescent nanocrystals markers that allow long photobleaching and do not destroy the parasites. In this paper, we used fluorescent core shell quantum dots to perform studies of live parasite-vector interaction processes without any observable effect on the vitality of parasites. These nanocrystals were synthesized in aqueous medium and physiological pH, which is very important for monitoring live cells activities, and conjugated with molecules such as lectins to label specific carbohydrates involved on the parasite-vector interaction. These QDs were successfully used for the study of in vitro and in vivo interaction of Trypanosoma cruzi and the triatomine Rhodnius prolixus. These QDs allowed us to acquire real time confocal images sequences of live T. cruzi-R. prolixus interactions for an extended period, causing no damage to the cells. By zooming to the region of interest, we have been able to acquire confocal images at the three to four frames per second rate. Our results show that QDs are physiological fluorescent markers capable to label living parasites and insect vector cells. QDs can be functionalized with lectins to specifically mark surface carbohydrates on perimicrovillar membrane of R. prolixus to follow, visualize, and understand interaction between vectors and its parasites in real-time.

  14. Alleviating artifacts in 1H MRI thermometry by single scan spatiotemporal encoding.

    PubMed

    Schmidt, Rita; Frydman, Lucio

    2013-10-01

    Recent years have seen an increased interest in combining MRI thermometry with devices capable of destroying malignancies by heat ablation. Expected from the MR protocols are accurate and fast thermal characterizations, providing real time feedback on restricted tissue volumes and/or rapidly moving organs like liver. This article explores the potential advantages of relying on spatiotemporally encoded (SPEN) sequences for retrieving real-time thermometric images based on the water's proton resonance frequency (PRF) shifts. Hybrid spatiotemporal/k-space encoding single-scan MRI experiments were implemented on animal and human scanners, and their abilities to deliver single- and multi-slice real-time thermometric measurements based on PRF-derived phase maps in phantoms and in vivo, were compared against echo planar imaging (EPI) and gradient-echo counterparts. Under comparable acquisition conditions, SPEN exhibited advantages vis-à-vis EPI in terms of dealing with inhomogeneous magnetic field distortions, with shifts arising due to changes in the central frequency offsets, with PRF distributions, and for zooming into restricted fields-of-view without special pulse sequence provisions. This work confirms the ability of SPEN sequences, particularly when implemented under fully-refocused conditions, to exploit their built-in robustness to shift- and field-derived inhomogeneities for monitoring thermal changes in real-time under in vitro and in vivo conditions.

  15. ViCoMo: visual context modeling for scene understanding in video surveillance

    NASA Astrophysics Data System (ADS)

    Creusen, Ivo M.; Javanbakhti, Solmaz; Loomans, Marijn J. H.; Hazelhoff, Lykele B.; Roubtsova, Nadejda; Zinger, Svitlana; de With, Peter H. N.

    2013-10-01

    The use of contextual information can significantly aid scene understanding of surveillance video. Just detecting people and tracking them does not provide sufficient information to detect situations that require operator attention. We propose a proof-of-concept system that uses several sources of contextual information to improve scene understanding in surveillance video. The focus is on two scenarios that represent common video surveillance situations, parking lot surveillance and crowd monitoring. In the first scenario, a pan-tilt-zoom (PTZ) camera tracking system is developed for parking lot surveillance. Context is provided by the traffic sign recognition system to localize regular and handicapped parking spot signs as well as license plates. The PTZ algorithm has the ability to selectively detect and track persons based on scene context. In the second scenario, a group analysis algorithm is introduced to detect groups of people. Contextual information is provided by traffic sign recognition and region labeling algorithms and exploited for behavior understanding. In both scenarios, decision engines are used to interpret and classify the output of the subsystems and if necessary raise operator alerts. We show that using context information enables the automated analysis of complicated scenarios that were previously not possible using conventional moving object classification techniques.

  16. Filling the assessment gap: using a learning portfolio in international development courses.

    PubMed

    Omar, Mayeh Abu

    2006-01-01

    The purpose of this research is to describe an action research project that proposed, monitored and evaluated the introduction of a learning portfolio used to replace examinations that were formerly used to assess the core courses. An action research project was undertaken to find out whether the introduction of a portfolio was successful and what could be improved in the process of its implementation. The findings indicate that portfolios are effective to support and assess the academic development of international students. The introduction of a portfolio to replace written examinations in the NCIHD was welcomed by all concerned.

  17. The endocrine pharmacology of testosterone therapy in men

    NASA Astrophysics Data System (ADS)

    Oettel, Michael

    The review starts off by outlining the history of the discovery of the male sex hormone testosterone and the historical background to the various, often dubious, approaches to the treatment of age-related endocrine disorders in older men. A discussion of congenital androgen deficiency in young men is followed by methods of diagnosing hypogonadism in older men. Among therapeutic options, the alternatives to direct testosterone replacement are discussed, although none of them have proved to be particularly successful in clinical practice. For testosterone replacement itself, various routes of administration and pharmaceutical formulations are now available, facilitating good monitoring and individualized therapy.

  18. Examining Mars at Many Levels (Artist Concept)

    NASA Image and Video Library

    2005-03-23

    This artist's concept represents the "Follow the Water" theme of NASA's Mars Reconnaissance Orbiter mission. The orbiter's science instruments monitor the present water cycle in the Mars atmosphere and the associated deposition and sublimation of water ice on the surface, while probing the subsurface to see how deep the water-ice reservoir detected by Mars Odyssey extends. At the same time, Mars Reconnaissance Orbiter will search for surface features and minerals (such as carbonates and sulfates) that record the extended presence of liquid water on the surface earlier in the planet's history. The instruments involved are the Shallow Subsurface Radar, the Compact Reconnaissance Imaging Spectrometer for Mars, the Mars Color Imager, the High Resolution Imaging Science Experiment, the Context Camera and the Mars Climate Sounder. To the far left, the radar antenna beams down and "sees" into the first few hundred feet (up to 1 kilometer) of Mars' crust. Just to the right of that, the next beam highlights the data received from the imaging spectrometer, which identifies minerals on the surface. The next beam represents the high-resolution camera, which can "zoom in" on local targets, providing the highest-resolution orbital images yet of features such as craters and gullies and rocks. The beam that shines almost horizontally is that of the Mars Climate Sounder. This instrument is critical to analyzing the current climate of Mars since it observes the temperature, humidity, and dust content of the martian atmosphere, and their seasonal and year-to-year variations. Meanwhile, the Mars Color Imager observes ice clouds, dust clouds and hazes, and the ozone distribution, producing daily global maps in multiple colors to monitor daily weather and seasonal changes. The electromagnetic spectrum is represented on the top right and individual instruments are placed where their capability lies. http://photojournal.jpl.nasa.gov/catalog/PIA07241

  19. Using remote sensing to monitor past changes and assess future scenarios for the Sacramento-San Joaquin River Delta waterways, California USA

    NASA Astrophysics Data System (ADS)

    Santos, Maria J.; Hestir, Erin; Khanna, Shruti; Ustin, Susan L.

    2017-04-01

    Historically, deltas have been extensively affected both by natural processes and human intervention. Thus, understanding drivers, predicting impacts and optimizing solutions to delta problems requires a holistic approach spanning many sectors, disciplines and fields of expertise. Deltas are ideal model systems to understand the effects of the interaction between social and ecological domains, as they face unprecedented disturbances and threats to their biological and ecological sustainability. The challenge for deltas is to meet the goals of supporting biodiversity and ecosystem processes while also provisioning fresh water resources for human use. We provide an overview of the last 150 years of the Sacramento-San Joaquin River delta, where we illustrate the parallel process of an increase in disturbances, by particularly zooming in on the current cascading effects of invasive species on geophysical and biological processes. Using remote sensing data coupled with in situ measurements of water quality, turbidity, and species presence we show how the spread and persistence of aquatic invasive species affects sedimentation processes and ecosystem functioning. Our results show that the interactions between the biological and physical conditions in the Delta affect the trajectory of dominance by native and invasive aquatic plant species. Trends in growth and community characteristics associated with predicted impacts of climate change (sea level rise, warmer temperatures, changes in the hydrograph with high winter and low summer outflows) do not provide simple predictions. Individually, the impact of specific environmental changes on the biological components can be predicted, however it is the complex interactions of biological communities with the suite of physical changes that make predictions uncertain. Systematic monitoring is critical to provide the data needed to document and understand change of these delta systems, and to identify successful adaptation strategies.

  20. Flood Vulnerability Assessment Map

    EIA Publications

    Maps of energy infrastructure with real-time storm and emergency information by fuel type and by state. Flood hazard information from FEMA has been combined with EIA's energy infrastructure layers as a tool to help state, county, city, and private sector planners assess which key energy infrastructure assets are vulnerable to rising sea levels, storm surges, and flash flooding. Note that flood hazard layers must be zoomed-in to street level before they become visible.

  1. Wide-Field Imaging System and Rapid Direction of Optical Zoom (WOZ)

    DTIC Science & Technology

    2011-03-25

    COMSOL Multiphysics, and ZEMAX optical design. The multiphysics design tool is nearing completion. We have demonstrated the ability to create a model in...and mechanical modeling to calculate the deformation resulting from the applied voltages. Finally, the deformed surface can be exported to ZEMAX via...MatLab. From ZEMAX , various analyses can be conducted to determine important parameters such as focal point, aberrations, and wavefront distortion

  2. Wide-field Imaging System and Rapid Direction of Optical Zoom (WOZ)

    DTIC Science & Technology

    2010-12-24

    The modeling tools are based on interaction between three commercial software packages: SolidWorks, COMSOL Multiphysics, and ZEMAX optical design...deformation resulting from the applied voltages. Finally, the deformed surface can be exported to ZEMAX via MatLab. From ZEMAX , various analyses can...results to extract from ZEMAX to support the optimization remains to be determined. Figure 1 shows the deformation calculated using a model of an

  3. Android Based Behavioral Biometric Authentication via Multi-Modal Fusion

    DTIC Science & Technology

    2014-06-12

    such as the way he or she uses the mouse, or interacts with the Graphical User Interface (GUI) [9]. Described simply, standard biometrics is determined...as a login screen on a standard computer. Active authentication is authentication that occurs dynamically throughout interaction with the device. A...because they are higher level constructs in themselves. The Android framework was specifically used for capturing the multitouch gestures: pinch and zoom

  4. Trends in Human-Computer Interaction to Support Future Intelligence Analysis Capabilities

    DTIC Science & Technology

    2011-06-01

    that allows data to be moved between different computing systems and displays. Figure 4- G-Speak gesture interaction (Oblong, 2011) 5.2 Multitouch ... Multitouch refers to a touchscreen interaction technique in which multiple simultaneous touchpoints and movements can be detected and used to...much of the style of interaction (such as rotate, pinch, zoom and flick movements) found in multitouch devices but can typically recognize more than

  5. Not slowing down | Center for Cancer Research

    Cancer.gov

    Nine and-a-half-year-old Travis Carpenter gets a lot of speeding tickets. (He stresses that “and-a-half” part, too). These speeding tickets don’t come from a law enforcement officer but Jesse, one of his nurses at the NIH Clinical Center. Travis uses a power chair that he’s adorned with racing stickers, and his speeding tickets come from him zooming down the Clinical Center’s

  6. Real-Time, Multiple, Pan/Tilt/Zoom, Computer Vision Tracking, and 3D Position Estimating System for Unmanned Aerial System Metrology

    DTIC Science & Technology

    2013-10-18

    of the enclosed tasks plus the last parallel task for a total of five parallel tasks for one iteration, i). for j = 1…N for i = 1… 8 Figure...drizzling juices culminating in a state of salivating desire to cut a piece and enjoy. On the other hand, the smell could be that of a pungent, unpleasant

  7. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KINKEL, C.C.

    1999-12-14

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less

  8. Remote monitoring of lower-limb prosthetic socket fit using wireless technologies.

    PubMed

    Sahandi, R; Sewell, P; Noroozi, S; Hewitt, M

    2012-01-01

    Accurate fitting of a lower-limb prosthetic socket is the most important factor affecting amputee satisfaction and rehabilitation. The technology is now available to allow real-time monitoring of in-service pressure distribution of prosthetic limbs. This paper proposes a remote interfacial pressure monitoring system necessary for the assessment of fit. The suitability of a wireless ZigBee network due to its relevant technical specification is investigated. The system enables remote monitoring of a prosthetic socket and its fit under different operating conditions thereby improving design, efficiency and effectiveness. The data can be used by prosthetists and may also be recorded for future training or for patient progress monitoring. This can minimize the number of iterations by getting it right first time, thereby minimizing the number of replacement prostheses. Copyright © 2012 Informa UK, Ltd.

  9. Improving Light Distribution by Zoom Lens for Electricity Savings in a Plant Factory with Light-Emitting Diodes.

    PubMed

    Li, Kun; Li, Zhipeng; Yang, Qichang

    2016-01-01

    The high energy consumption of a plant factory is the biggest issue in its rapid expansion, especially for lighting electricity, which has been solved to a large extent by light-emitting diodes (LED). However, the remarkable potential for further energy savings remains to be further investigated. In this study, an optical system applied just below the LED was designed. The effects of the system on the growth and photosynthesis of butterhead lettuce (Lactuca sativa var. capitata) were examined, and the performance of the optical improvement in energy savings was evaluated by comparison with the traditional LED illumination mode. The irradiation patterns used were LED with zoom lenses (Z-LED) and conventional non-lenses LED (C-LED). The seedlings in both treatments were exposed to the same light environment over the entire growth period. The improvement saved over half of the light source electricity, while prominently lowering the temperature. Influenced by this, the rate of photosynthesis sharply decreased, causing reductions in plant yield and nitrate content, while having no negative effects on morphological parameters and photosynthetic pigment contents. Nevertheless, the much higher light use efficiency of Z-LEDs makes this system a better approach to illumination in a plant factory with artificial lighting.

  10. Improving Light Distribution by Zoom Lens for Electricity Savings in a Plant Factory with Light-Emitting Diodes

    PubMed Central

    Li, Kun; Li, Zhipeng; Yang, Qichang

    2016-01-01

    The high energy consumption of a plant factory is the biggest issue in its rapid expansion, especially for lighting electricity, which has been solved to a large extent by light-emitting diodes (LED). However, the remarkable potential for further energy savings remains to be further investigated. In this study, an optical system applied just below the LED was designed. The effects of the system on the growth and photosynthesis of butterhead lettuce (Lactuca sativa var. capitata) were examined, and the performance of the optical improvement in energy savings was evaluated by comparison with the traditional LED illumination mode. The irradiation patterns used were LED with zoom lenses (Z-LED) and conventional non-lenses LED (C-LED). The seedlings in both treatments were exposed to the same light environment over the entire growth period. The improvement saved over half of the light source electricity, while prominently lowering the temperature. Influenced by this, the rate of photosynthesis sharply decreased, causing reductions in plant yield and nitrate content, while having no negative effects on morphological parameters and photosynthetic pigment contents. Nevertheless, the much higher light use efficiency of Z-LEDs makes this system a better approach to illumination in a plant factory with artificial lighting. PMID:26904062

  11. Web-based metabolic network visualization with a zooming user interface

    PubMed Central

    2011-01-01

    Background Displaying complex metabolic-map diagrams, for Web browsers, and allowing users to interact with them for querying and overlaying expression data over them is challenging. Description We present a Web-based metabolic-map diagram, which can be interactively explored by the user, called the Cellular Overview. The main characteristic of this application is the zooming user interface enabling the user to focus on appropriate granularities of the network at will. Various searching commands are available to visually highlight sets of reactions, pathways, enzymes, metabolites, and so on. Expression data from single or multiple experiments can be overlaid on the diagram, which we call the Omics Viewer capability. The application provides Web services to highlight the diagram and to invoke the Omics Viewer. This application is entirely written in JavaScript for the client browsers and connect to a Pathway Tools Web server to retrieve data and diagrams. It uses the OpenLayers library to display tiled diagrams. Conclusions This new online tool is capable of displaying large and complex metabolic-map diagrams in a very interactive manner. This application is available as part of the Pathway Tools software that powers multiple metabolic databases including Biocyc.org: The Cellular Overview is accessible under the Tools menu. PMID:21595965

  12. Zoom In! A Nanoscience Claymation Video Project Designed for Students K-3

    NASA Astrophysics Data System (ADS)

    Sandler, Nancy; Ulloa, Sergio; Raney, Kate

    2014-03-01

    Nanoscience concepts are somewhat new and strange to the general public, and although simple to explain, have not permeated through the various information channels available for public education. This is particularly true for children. Because young people in levels K-3 are exposed to digital media on a daily basis, we recognized the importance of reaching them using a familiar format. Hence, we developed a claymation Zoom In! movie that follows the ``adventures'' of Gwen Pym, a girl ``nanoscientist,'' in her quest for a dress that cannot be stained. The pilot video presented in this talk provides a novel and imaginative way to capture young children's attention while focusing on basic nanoscience concepts. By reducing Gwen to a sub-milimeter scale, concepts of scale, surface tension, hydrophobicity induced by roughness, are all exemplified in simple terms accessible to this age range. The movie is accompanied by supporting material aimed at schoolteachers, covering the physics concepts involved in the various aspects of the adventure, and including suggested on-class activities that expand on these points. The final product is contained in a DVD that was distributed to the local elementary schools in the South East Ohio area. Supported by the APS Physics on the Road Program.

  13. Simulations and experiments on vibration damping for zoom-holography and nano-scanning at the GINIX

    NASA Astrophysics Data System (ADS)

    Osterhoff, Markus; Luley, Peter; Sprung, Michael; Salditt, Tim

    2017-09-01

    The Göttingen Instrument for Nano-Imaging with X-ray (GINIX) is a holography endstation located at the P10 coherence beamline at PETRA III, designed and operated by the University of Göttingen in close collaboration with DESY Photon science Hamburg [1-2]. GINIX is designed as a waveguide based holography experiment with a Kirkpatrick-Baez nanofocus. Its versatility has stimulated a great manifold of imaging modalities. Today, users choose the GINIX setup not only for its few nm coherent waveguide beams (e.g. for ptychography or holography), but also to carry out scanning SAXS measurements to probe local anisotropies with sub-micron real-space and even higher reciprocal space resolution. In addition, it is possible to combine different detectors for e.g. simultaneous SAXS/WAXS and fluorescence measurements [3]. We summarise our ongoing efforts to reduce vibrations in the setup, and present latest experimental results obtained with GINIX, focusing on the unique capabilities offered by its versatile and flexible design. The overview includes results from different imaging schemes such as waveguide based zoom-tomography and user examples in WAXS geometry. We show how to correlate complementary techniques like holography and scanning SAXS and present first results obtained using a new fast sample scanner for Multilayer Zone Plate imaging..

  14. [Reliability of iWitness photogrammetry in maxillofacial application].

    PubMed

    Jiang, Chengcheng; Song, Qinggao; He, Wei; Chen, Shang; Hong, Tao

    2015-06-01

    This study aims to test the accuracy and precision of iWitness photogrammetry for measuring the facial tissues of mannequin head. Under ideal circumstances, the 3D landmark coordinates were repeatedly obtained from a mannequin head using iWitness photogrammetric system with different parameters, to examine the precision of this system. The differences between the 3D data and their true distance values of mannequin head were computed. Operator error of 3D system in non-zoom and zoom status were 0.20 mm and 0.09 mm, and the difference was significant (P 0.05). Image captured error of 3D system was 0.283 mm, and there was no significant difference compared with the same group of images (P>0.05). Error of 3D systen with recalibration was 0.251 mm, and the difference was not statistically significant compared with image captured error (P>0.05). Good congruence was observed between means derived from the 3D photos and direct anthropometry, with difference ranging from -0.4 mm to +0.4 mm. This study provides further evidence of the high reliability of iWitness photogrammetry for several craniofacial measurements, including landmarks and inter-landmark distances. The evaluated system can be recommended for the evaluation and documentation of the facial surface.

  15. Exogenous and endogenous control of attention: the effect of visual onsets and offsets.

    PubMed

    Theeuwes, J

    1991-01-01

    Two experiments were carried out to investigate the relation between exogenous and endogenous control of visual attention. Subjects searched for a target letter among three nontarget letters that were positioned on an imaginary circle around a fixation point. At different cue-display intervals, a centrally located arrowhead cue reliably indicated the location of the target letter. At different SOAs, a peripheral line segment near one of the letters was either abruptly switched on (Experiment 1) or abruptly switched off (Experiment 2). Presenting the central arrowhead after display onset prevents attention from being focused in advance on the critical location. In this unfocused attentional state, both onset and offset transients attracted attention. When the central arrowhead was available in advance, the focusing of attention prior to display onset precluded attention attraction to the location of the onset or offset transient. Contrary to an offset transient, an onset transient presented at the attended location disrupted performance, indicating that an onset within the spotlight of attention attracts attention. The results are reconciled by means of the zoom-lens theory of attention, suggesting that outside the focus of attention, abrupt transients are not capable of attracting attention. Since the size of the zoom lens is under voluntary control, it can be argued that transients do not fulfill the intentionality criterion of automaticity.

  16. The Simple Map for a Single-null Divertor Tokamak: How to Look for Self-Similarity in Chaos

    NASA Astrophysics Data System (ADS)

    Nguyen, Christina; Ali, Halima; Punjabi, Alkesh

    2000-10-01

    The movement of magnetic field lines inside a single-null divertor tokamak can be described by the Simple Map^1. The Simple Map in the Poincaré Surface of Section is given by the equations: X_1=X_0-KY_0(1-Y_0) and Y_1=Y_0+KX_1. In these equations, K remains constant at 0.60. However, the values for X0 and Y0 are changed. These values are changed so that we can zoom into chaos. Chaos lies between the region (0,0.997) and (0,1). In chaos, there lies order. As we zoom into chaos, we again find chaos and order that looks like the original good surfaces and chaos. This phenomenon is called self-similarity. Self-similarity can occur for an infinite number of times if one magnifies into the chaotic region. For this work, we write a program in a computer language called Fortran 77 and Gnuplot. This work is supported by US DOE OFES. Ms. Christina Nguyen is a HU CFRT Summer Fusion High School Workshop Scholar from Andrew Hill High School in California. She is supported by NASA SHARP Plus Program. 1. Punjabi A, Verma A and Boozer A, Phys Rev Lett 69 3322 (1992) and J Plasma Phys 52 91 (1994)

  17. Detection of inter-frame forgeries in digital videos.

    PubMed

    K, Sitara; Mehtre, B M

    2018-05-26

    Videos are acceptable as evidence in the court of law, provided its authenticity and integrity are scientifically validated. Videos recorded by surveillance systems are susceptible to malicious alterations of visual content by perpetrators locally or remotely. Such malicious alterations of video contents (called video forgeries) are categorized into inter-frame and intra-frame forgeries. In this paper, we propose inter-frame forgery detection techniques using tamper traces from spatio-temporal and compressed domains. Pristine videos containing frames that are recorded during sudden camera zooming event, may get wrongly classified as tampered videos leading to an increase in false positives. To address this issue, we propose a method for zooming detection and it is incorporated in video tampering detection. Frame shuffling detection, which was not explored so far is also addressed in our work. Our method is capable of differentiating various inter-frame tamper events and its localization in the temporal domain. The proposed system is tested on 23,586 videos of which 2346 are pristine and rest of them are candidates of inter-frame forged videos. Experimental results show that we have successfully detected frame shuffling with encouraging accuracy rates. We have achieved improved accuracy on forgery detection in frame insertion, frame deletion and frame duplication. Copyright © 2018. Published by Elsevier B.V.

  18. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Structural health monitoring of I-10 twin span bridge : [tech summary].

    DOT National Transportation Integrated Search

    2014-11-01

    A new I-10 Twin Span Bridge was built over Lake Pontchartrain between New Orleans and Slidell, Louisiana to replace the old bridge : that was seriously damaged from the storm surge associated with Hurricane Katrina (Category 3) that hit the southern ...

  20. Evaluation of Data Replacement Strategies for CASTNET Dry Deposition Modeling

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) established the Clean Air Status and Trends Network (CASTNET) and its predecessor, the National Dry Deposition Network (NDDN), as national air quality and meteorological monitoring networks. The purpose of CASTNET is to track the pr...

  1. Helmet system broadcasts electroencephalograms of wearer

    NASA Technical Reports Server (NTRS)

    Westbrook, R. M.; Zuccaro, J. J.

    1966-01-01

    EEG monitoring system consisting of nonirritating sponge-type electrodes, amplifiers, and a battery-powered wireless transmitter, all mounted in the subjects helmet, obtains electroencephalograms /EEGs/ of pilots and astronauts performing tasks under stress. After a quick initial fitting, the helmet can be removed and replaced without adjustments.

  2. Route 22 Over Liberty Avenue and Conrail Hillside Township, Union County, Monitoring of Tensar MSE Walls

    DOT National Transportation Integrated Search

    2011-12-01

    This report discusses the application of Tensar geogrids as the reinforcement elements in the : construction of mechanically stabilized earth (MSE) walls on the Route 22 over Conrail and Liberty : Avenue bridge replacement project in Hillside, NJ. As...

  3. Personal Alarm System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-04-17

    Software that runs on smartphones and desktop web browsers and notifies border officials of radiation alarms. It displays images and data associated with an alarm and provides a variety of reports. DOE had a need for discrete notification. PAS replaces the lights and sounds of a Radiation Portal Monitor.

  4. Restore McComas Meadows; Meadow Creek Watershed, 2005-2006 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McRoberts, Heidi

    2006-07-01

    The Nez Perce Tribe Department of Fisheries Resource Management, Watershed Division approaches watershed restoration with a ridge-top to ridge-top approach. Watershed restoration projects within the Meadow Creek watershed are coordinated and cost shared with the Nez Perce National Forest. The Nez Perce Tribe began watershed restoration projects within the Meadow Creek watershed of the South Fork Clearwater River in 1996. Progress has been made in restoring the watershed by excluding cattle from critical riparian areas through fencing, planting trees in riparian areas within the meadow and its tributaries, prioritizing culverts for replacement to accommodate fish passage, and decommissioning roads tomore » reduce sediment input. During this contract period work was completed on two culvert replacement projects; Doe Creek and a tributary to Meadow Creek. Additionally construction was also completed for the ditch restoration project within McComas Meadows. Monitoring for project effectiveness and trends in watershed conditions was also completed. Road decommissioning monitoring, as well as stream temperature, sediment, and discharge were completed.« less

  5. The effect of operating conditions on the performance of soil slurry-SBRs.

    PubMed

    Cassidy, D P; Irvine, R L

    2001-01-01

    Biological treatment of a silty clay loam with aged diesel fuel contamination was conducted in 8 L Soil Slurry-Sequencing Batch Reactors (SS-SBRs). The purpose was to monitor slurry conditions and evaluate reactor performance for varying solids concentration (5%, 25%, 40%, 50%), mixing speed (300 rpm, 700 rpm, 1200 rpm), retention time (8 d, 10 d, 20 d), and volume replaced per cycle (10%, 50%, 90%). Diesel fuel was measured in slurry and in filtered aqueous samples. Oxygen uptake rate (OUR) was monitored. Aggregate size was measured with sieve analyses. Biosurfactant production was quantified with surface tension measurements. Increasing solids concentration and decreasing mixing speed resulted in increased aggregate size, which in turn increased effluent diesel fuel concentrations. Diesel fuel removal was unaffected by retention time and volume replaced per cycle. Biosurfactant production occurred with all operating strategies. Foam thickness was related to surfactant concentration and mixing speed. OUR, surfactant concentration, and foam thickness increased with increasing diesel fuel added per cycle.

  6. The Photogrammetry Cube

    NASA Technical Reports Server (NTRS)

    2008-01-01

    We can determine distances between objects and points of interest in 3-D space to a useful degree of accuracy from a set of camera images by using multiple camera views and reference targets in the camera s field of view (FOV). The core of the software processing is based on the previously developed foreign-object debris vision trajectory software (see KSC Research and Technology 2004 Annual Report, pp. 2 5). The current version of this photogrammetry software includes the ability to calculate distances between any specified point pairs, the ability to process any number of reference targets and any number of camera images, user-friendly editing features, including zoom in/out, translate, and load/unload, routines to help mark reference points with a Find function, while comparing them with the reference point database file, and a comprehensive output report in HTML format. In this system, scene reference targets are replaced by a photogrammetry cube whose exterior surface contains multiple predetermined precision 2-D targets. Precise measurement of the cube s 2-D targets during the fabrication phase eliminates the need for measuring 3-D coordinates of reference target positions in the camera's FOV, using for example a survey theodolite or a Faroarm. Placing the 2-D targets on the cube s surface required the development of precise machining methods. In response, 2-D targets were embedded into the surface of the cube and then painted black for high contrast. A 12-inch collapsible cube was developed for room-size scenes. A 3-inch, solid, stainless-steel photogrammetry cube was also fabricated for photogrammetry analysis of small objects.

  7. Disc-halo interactions in ΛCDM

    NASA Astrophysics Data System (ADS)

    Bauer, Jacob S.; Widrow, Lawrence M.; Erkal, Denis

    2018-05-01

    We present a new method for embedding a stellar disc in a cosmological dark matter halo and provide a worked example from a Λ cold dark matter zoom-in simulation. The disc is inserted into the halo at a redshift z = 3 as a zero-mass rigid body. Its mass and size are then increased adiabatically while its position, velocity, and orientation are determined from rigid-body dynamics. At z = 1, the rigid disc (RD) is replaced by an N-body disc whose particles sample a three-integral distribution function (DF). The simulation then proceeds to z = 0 with live disc (LD) and halo particles. By comparison, other methods assume one or more of the following: the centre of the RD during the growth phase is pinned to the minimum of the halo potential, the orientation of the RD is fixed, or the live N-body disc is constructed from a two rather than three-integral DF. In general, the presence of a disc makes the halo rounder, more centrally concentrated, and smoother, especially in the innermost regions. We find that methods in which the disc is pinned to the minimum of the halo potential tend to overestimate the amount of adiabatic contraction. Additionally, the effect of the disc on the subhalo distribution appears to be rather insensitive to the disc insertion method. The LD in our simulation develops a bar that is consistent with the bars seen in late-type spiral galaxies. In addition, particles from the disc are launched or `kicked up' to high galactic latitudes.

  8. The Trilogy is Complete - GigaGalaxy Zoom Phase 3

    NASA Astrophysics Data System (ADS)

    2009-09-01

    The third image of ESO's GigaGalaxy Zoom project has just been released online, completing this eye-opening dive into our galactic home in outstanding fashion. The latest image follows on from views, released over the last two weeks, of the sky as seen with the unaided eye and through an amateur telescope. This third instalment provides another breathtaking vista of an astronomical object, this time a 370-million-pixel view of the Lagoon Nebula of the quality and depth needed by professional astronomers in their quest to understand our Universe. The newly released image extends across a field of view of more than one and a half square degree - an area eight times larger than that of the full Moon - and was obtained with the Wide Field Imager attached to the MPG/ESO 2.2-metre telescope at the La Silla Observatory in Chile. This 67-million-pixel camera has already created several of ESO's iconic pictures. The intriguing object depicted here - the Lagoon Nebula - is located four to five thousand light-years away towards the constellation of Sagittarius (the Archer). The nebula is a giant interstellar cloud, 100 light-years across, where stars are forming. The scattered dark patches seen all over the nebula are huge clouds of gas and dust that are collapsing under their own weight and which will soon give birth to clusters of young, glowing stars. Some of the smallest clouds are known as "globules" and the most prominent ones have been catalogued by the astronomer Edward Emerson Barnard. The Lagoon Nebula hosts the young open stellar cluster known as NGC 6530. This is home for 50 to 100 stars and twinkles in the lower left portion of the nebula. Observations suggest that the cluster is slightly in front of the nebula itself, though still enshrouded by dust, as revealed by reddening of the starlight, an effect that occurs when small dust particles scatter light. The name of the Lagoon Nebula derives from the wide lagoon-shaped dark lane located in the middle of the nebula that divides it into two glowing sections. This gorgeous starscape is the last in the series of three huge images featured in the GigaGalaxy Zoom project, launched by ESO as part of the International Year of Astronomy 2009 (IYA2009). Through three giant images, the GigaGalaxy Zoom project reveals the full sky as it appears with the unaided eye from one of the darkest deserts on Earth, then zooms in on a rich region of the Milky Way using an amateur telescope, and finally uses the power of a professional telescope to reveal the details of a famous nebula. In this way, the project links the sky we can all see with the deep, "hidden" cosmos that astronomers study on a daily basis. The wonderful quality of the images is a testament to the splendour of the night sky at ESO's sites in Chile, which are the most productive astronomical observatories in the world. "The GigaGalaxy Zoom project's dedicated website has proved very successful, drawing hundreds of thousands of visitors from all around the world," says project coordinator Henri Boffin. "With the trilogy now complete, viewers will be able to explore a magnificently detailed cosmic environment on many different scales and take a breathtaking dive into our Milky Way." More information As part of the IYA2009, ESO is participating in several remarkable outreach activities, in line with its world-leading rank in the field of astronomy. ESO is hosting the IYA2009 Secretariat for the International Astronomical Union, which coordinates the Year globally. ESO is one of the Organisational Associates of IYA2009, and was also closely involved in the resolution submitted to the United Nations (UN) by Italy, which led to the UN's 62nd General Assembly proclaiming 2009 the International Year of Astronomy. In addition to a wide array of activities planned both at the local and international level, ESO is leading four of the thirteen global Cornerstone Projects. ESO, the European Southern Observatory, is the foremost intergovernmental astronomy organisation in Europe and the world's most productive astronomical observatory. It is supported by 14 countries: Austria, Belgium, the Czech Republic, Denmark, France, Finland, Germany, Italy, the Netherlands, Portugal, Spain, Sweden, Switzerland and the United Kingdom. ESO carries out an ambitious programme focused on the design, construction and operation of powerful ground-based observing facilities enabling astronomers to make important scientific discoveries. ESO also plays a leading role in promoting and organising cooperation in astronomical research. ESO operates three unique world-class observing sites in Chile: La Silla, Paranal and Chajnantor. At Paranal, ESO operates the Very Large Telescope, the world's most advanced visible-light astronomical observatory. ESO is the European partner of a revolutionary astronomical telescope ALMA, the largest astronomical project in existence. ESO is currently planning a 42-metre European Extremely Large optical/near-infrared Telescope, the E-ELT, which will become "the world's biggest eye on the sky". The third image of the GigaGalaxy Zoom project was taken with the Wide Field Imager (WFI) attached to the MPG/ESO 2.2-metre telescope at the ESO La Silla Observatory. In order to optimise telescope time, the images were obtained by ESO staff astronomers, who select the most favourable observations to be made at any given time, taking into account the visibility of the objects and the sky conditions. The La Silla Observatory, 600 km north of Santiago de Chile and at an altitude of 2400 metres, has been an ESO stronghold since the 1960s. Here, ESO operates several of the most productive 2-4-metre-class telescopes in the world.

  9. [Newly developed monitor for IVR: liquid crystal display (LCD) replaced with cathode ray tube (CRT)].

    PubMed

    Ichida, Takao; Hosogai, Minoru; Yokoyama, Kouji; Ogawa, Takayoshi; Okusako, Kenji; Shougaki, Masachika; Masai, Hironao; Yamada, Eiji; Okuyama, Kazuo; Hatagawa, Masakatsu

    2004-09-01

    For physicians who monitor images during interventional radiology (VR), we have built and been using a system that employs a liquid crystal display (LCD) instead of the conventional cathode ray tube (CRT). The system incorporates a ceiling-suspension-type monitor (three-display monitor) with an LCD on each of the three displays for the head and abdominal regions and another ceiling-suspension-type monitor (5-display monitor) with an LCD on each display for the cardiac region. As these monitors are made to be thin and light in weight, they can be placed in a high position in the room, thereby saving space and allowing for more effective use of space in the X-ray room. The system has also improved the efficiency of operators in the IVR room. The three-display folding mechanism allows the displays to be viewed from multiple directions, thereby improving the environment so that the performance of IVR can be observed.

  10. Neurodevelopmental and body composition outcomes in children with congenital hypothyroidism treated with high-dose initial replacement and close monitoring.

    PubMed

    Albert, Benjamin B; Heather, Natasha; Derraik, José G B; Cutfield, Wayne S; Wouldes, Trecia; Tregurtha, Sheryl; Mathai, Sarah; Webster, Dianne; Jefferies, Craig; Gunn, Alistair J; Hofman, Paul L

    2013-09-01

    Despite newborn screening and early levothyroxine replacement, there are continued reports of mild neurocognitive impairment in children with congenital hypothyroidism (CHT). In Auckland, New Zealand, cases are identified by a neonatal screening program with rapid institution of high-dose levothyroxine replacement (10-15 μg/kg·d), producing prompt normalization of thyroid function. Subsequently, frequent monitoring and dose alterations are performed for 2 years. We aimed to assess whether the Auckland treatment strategy prevents impairment of intellectual and motor development. This study encompassed all children with CHT born in 1993-2006 in Auckland and their siblings. Neurocognitive assessments included the following: 1) intelligence quotient via Weschler Preschool and Primary Scale of Intelligence III or Weschler Intelligence Scale for Children IV; 2) Movement Assessment Battery for Children; and 3) Beery Developmental Test of Visual-Motor Integration. Body composition was assessed by dual-energy x-ray absorptiometry. Forty-four CHT cases and 53 sibling controls aged 9.6 ± 3.9 years were studied. Overall intelligence quotient was similar among CHT cases and controls (95.2 vs 98.6; P = .20), and there were also no differences in motor function. Severity of CHT did not influence outcome, but greater time to normalize free T4 was associated with worse motor balance. There were no differences in anthropometry or body composition between groups. These findings suggest that a strategy of rapidly identifying and treating infants with CHT using high-dose levothyroxine replacement is associated with normal intellectual and motor development. The subtle negative impact on motor function associated with time to normalize free T4 levels is consistent with benefit from rapid initial correction.

  11. In-situ photopolymerization and monitoring device for controlled shaping of tissue fillers, replacements, or implants

    NASA Astrophysics Data System (ADS)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2015-03-01

    Photopolymerization is a common tool to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler simply by illumination. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. However, at the device level, surgical endoscopic probes are required. We present a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 1 mm in diameter. Beside basic injection mechanics, the tool consists of an optical fiber guiding the light required for photopolymerization and for chemical analysis. Combining photorheology and fluorescence spectroscopy, the current state of the photopolymerization is inferred and monitored in real time. Biocompatible and highly tuneable Poly-Ethylene-Glycol (PEG) hydrogels were used as the injection material. The device was tested on a model for intervertebral disc replacement. Gels were successfully implanted into a bovine caudal model and mechanically tested in-vitro during two weeks. The photopolymerized gel was evaluated at the tissue level (adherence and mechanical properties of the implant), at the cellular level (biocompatibility and cytotoxicity) and ergonomic level (sterilization procedure and feasibility study). This paper covers the monitoring aspect of the device.

  12. Findings of an observational investigation of pure remote follow-up of pacemaker patients: is the in-clinic device check still needed?

    PubMed

    Facchin, D; Baccillieri, M S; Gasparini, G; Zoppo, F; Allocca, G; Brieda, M; Verlato, R; Proclemer, A

    2016-10-01

    Device follow-up is mandatory in the care of patients with a pacemaker. However, in most cases, device checks appear to be mere technical, time-consuming procedures. The aim of this research is to evaluate whether remote follow-up can replace in-clinic device checks by assessing clinical outcomes for pacemaker patients followed only via remote follow-up. Consecutive pacemaker patients followed with remote monitoring were prospectively included by 6 Italian cardiology centers in an observational investigation. The workflow for remote monitoring included an initial assessment by nursing staff and, when necessary, by a responsible physician for medical decisions. No in-person visits were scheduled after the start of remote monitoring. One-thousand and two-hundred and fifty one patients (30% female, 75±11years old) were followed for a median observation period of 15months. Out of 4965 remote transmissions, 1882 (38%) had at least one clinically relevant event to be investigated further, but, only after 137 transmissions (2.8%), the patients were contacted for an in-clinic visit or hospitalization. Sixty-nine patients died and 124 were hospitalized for various reasons. Atrial fibrillation episodes were the most common clinical events discovered by remote transmissions, occurring in 1339 (26%) transmissions and 471 (38%) patients. Our experience shows that remote monitoring in a pacemaker population can safely replace in-clinic follow-up, avoiding unnecessary in-hospital device follow-up. Copyright © 2016. Published by Elsevier Ireland Ltd.

  13. Development and Performance of the Oxygen Sensor in the CSA-CP Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Beck, Steve; James, John T.

    2004-01-01

    A combustion products analyzer (CPA) was built for use on Shuttle in response to several thermodegradation incidents that had occurred during early flights. The CPA contained sensors that measured carbon monoxide, hydrogen chloride, hydrogen cyanide, and hydrogen fluoride. These marker compounds, monitored by the CPA, were selected based upon the likely products to be released in a spacecraft fire. When the Toxicology Laboratory group at Johnson Space Center (JSC) began to assess the air quality monitoring needs for the International Space Station (ISS), the CPA was the starting point for design of an instrument to monitor the atmosphere following a thermodegradation event. The final product was significantly different from the CPA and was named the compound specific analyzer-combustion products (CSA-CP). The major change from the CPA that will be the focus of this paper was the replacement of an unreliable hydrogen fluoride (HF) sensor with an oxygen sensor. A reliable HF sensor was not commercially available, but as the toxicology group reviewed the overall monitoring strategy for ISS, it appeared that a portable oxygen sensor to backup the major constituent analyzer was needed. Therefore, an oxygen sensor replaced the HF sensor in the new instrument. This paper will describe the development, deployment, and performance of the CSA-CP oxygen sensor on both Shuttle and ISS. Also, data for CSA-CP oxygen sensor accuracy at nominal and reduced pressures will be presented.

  14. Verification of rut depth collected with the INO laser rut measurement system (LRMS).

    DOT National Transportation Integrated Search

    2011-10-28

    Pavement rutting can be an indicator that a section of roadway is in need of repair or replacement. It can also become : a hazard to drivers, causing loss of control or hydroplaning when water accumulates. To better monitor pavement : conditions thro...

  15. 40 CFR 74.10 - Roles-EPA and permitting authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... allowance allocation, and allocating allowances for combustion or process sources that become affected units under this part; (2) Certifying or recertifying monitoring systems for combustion or process sources as... accounting for the replacement of thermal energy, closing accounts for opt-in sources that shut down, are...

  16. Structure of a financial cross-correlation matrix under attack

    NASA Astrophysics Data System (ADS)

    Lim, Gyuchang; Kim, SooYong; Kim, Junghwan; Kim, Pyungsoo; Kang, Yoonjong; Park, Sanghoon; Park, Inho; Park, Sang-Bum; Kim, Kyungsik

    2009-09-01

    We investigate the structure of a perturbed stock market in terms of correlation matrices. For the purpose of perturbing a stock market, two distinct methods are used, namely local and global perturbation. The former involves replacing a correlation coefficient of the cross-correlation matrix with one calculated from two Gaussian-distributed time series while the latter reconstructs the cross-correlation matrix just after replacing the original return series with Gaussian-distributed time series. Concerning the local case, it is a technical study only and there is no attempt to model reality. The term ‘global’ means the overall effect of the replacement on other untouched returns. Through statistical analyses such as random matrix theory (RMT), network theory, and the correlation coefficient distributions, we show that the global structure of a stock market is vulnerable to perturbation. However, apart from in the analysis of inverse participation ratios (IPRs), the vulnerability becomes dull under a small-scale perturbation. This means that these analysis tools are inappropriate for monitoring the whole stock market due to the low sensitivity of a stock market to a small-scale perturbation. In contrast, when going down to the structure of business sectors, we confirm that correlation-based business sectors are regrouped in terms of IPRs. This result gives a clue about monitoring the effect of hidden intentions, which are revealed via portfolios taken mostly by large investors.

  17. A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin

    NASA Astrophysics Data System (ADS)

    Sung, Tzu-Cheng; Chen, Wen-Yih; Shah, Pramod; Chen, Chien-Sheng

    2016-02-01

    Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays.

  18. Nocturnal Hypoglycemia Identified by a Continuous Glucose Monitoring System in Patients with Primary Adrenal Insufficiency (Addison's Disease)

    PubMed Central

    Hackemann, Annika; Reusch, Juergen; Badenhoop, Klaus

    2012-01-01

    Abstract Background Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Methods Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3–5 days. Results In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Conclusions Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects. PMID:22242902

  19. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    PubMed

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  20. Internet based ECG medical information system.

    PubMed

    James, D A; Rowlands, D; Mahnovetski, R; Channells, J; Cutmore, T

    2003-03-01

    Physiological monitoring of humans for medical applications is well established and ready to be adapted to the Internet. This paper describes the implementation of a Medical Information System (MIS-ECG system) incorporating an Internet based ECG acquisition device. Traditionally clinical monitoring of ECG is largely a labour intensive process with data being typically stored on paper. Until recently, ECG monitoring applications have also been constrained somewhat by the size of the equipment required. Today's technology enables large and fixed hospital monitoring systems to be replaced by small portable devices. With an increasing emphasis on health management a truly integrated information system for the acquisition, analysis, patient particulars and archiving is now a realistic possibility. This paper describes recent Internet and technological advances and presents the design and testing of the MIS-ECG system that utilises those advances.

Top