Sample records for monitoring protocol deviations

  1. Attacks exploiting deviation of mean photon number in quantum key distribution and coin tossing

    NASA Astrophysics Data System (ADS)

    Sajeed, Shihan; Radchenko, Igor; Kaiser, Sarah; Bourgoin, Jean-Philippe; Pappa, Anna; Monat, Laurent; Legré, Matthieu; Makarov, Vadim

    2015-03-01

    The security of quantum communication using a weak coherent source requires an accurate knowledge of the source's mean photon number. Finite calibration precision or an active manipulation by an attacker may cause the actual emitted photon number to deviate from the known value. We model effects of this deviation on the security of three quantum communication protocols: the Bennett-Brassard 1984 (BB84) quantum key distribution (QKD) protocol without decoy states, Scarani-Acín-Ribordy-Gisin 2004 (SARG04) QKD protocol, and a coin-tossing protocol. For QKD we model both a strong attack using technology possible in principle and a realistic attack bounded by today's technology. To maintain the mean photon number in two-way systems, such as plug-and-play and relativistic quantum cryptography schemes, bright pulse energy incoming from the communication channel must be monitored. Implementation of a monitoring detector has largely been ignored so far, except for ID Quantique's commercial QKD system Clavis2. We scrutinize this implementation for security problems and show that designing a hack-proof pulse-energy-measuring detector is far from trivial. Indeed, the first implementation has three serious flaws confirmed experimentally, each of which may be exploited in a cleverly constructed Trojan-horse attack. We discuss requirements for a loophole-free implementation of the monitoring detector.

  2. Protocol deviations before and after IV tPA in community hospitals

    PubMed Central

    Adelman, Eric E.; Scott, Phillip A.; Skolarus, Lesli E.; Fox, Allison K.; Frederiksen, Shirley M.; Meurer, William J.

    2015-01-01

    Background Protocol deviations before and after tPA treatment for ischemic stroke are common. It is unclear if patient or hospital factors predict protocol deviations. We examined predictors of protocol deviations and the effects of protocol violations on symptomatic intracerebral hemorrhage. Methods We used data from the INSTINCT trial, a cluster-randomized, controlled trial evaluating the efficacy of a barrier assessment and educational intervention to increase appropriate tPA use in 24 Michigan community hospitals, to review tPA treatments between 2007 and 2010. Protocol violations were defined as deviations from the standard tPA protocol, both before and after treatment. Multi-level logistic regression models were fitted to determine if patient and hospital variables were associated with pre-treatment or post-treatment protocol deviations. Results During the study, 557 patients (mean age 70; 52% male; median NIHSS 12) were treated with tPA. Protocol deviations occurred in 233 (42%) patients: 16% had pre-treatment deviations, 35% had post-treatment deviations, and 9% had both. The most common protocol deviations included elevated post-treatment blood pressure, antithrombotic agent use within 24 hours of treatment, and elevated pre-treatment blood pressure. Protocol deviations were not associated with symptomatic intracerebral hemorrhage, stroke severity, or hospital factors. Older age was associated with pre-treatment protocol deviations (adjusted OR 0.52; 95% confidence interval 0.30-0.92). Pre-treatment deviations were associated with post-treatment deviations (adjusted OR 3.20; 95% confidence interval 1.91-5.35). Conclusions Protocol deviations were not associated with symptomatic intracerebral hemorrhage. Aside from age, patient and hospital factors were not associated with protocol deviations. PMID:26419527

  3. In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.

    PubMed

    Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J

    2004-01-01

    In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.

  4. Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin

    2011-02-01

    Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.

  5. Investigation of the Study Characteristics Affecting Clinical Trial Quality Using the Protocol Deviations Leading to Exclusion of Subjects From the Per Protocol Set Data in Studies for New Drug Application: A Retrospective Analysis.

    PubMed

    Kohara, Norihito; Kaneko, Masayuki; Narukawa, Mamoru

    2018-01-01

    The concept of the risk-based approach has been introduced as an effort to secure the quality of clinical trials. In the risk-based approach, identification and evaluation of risk in advance are considered important. For recently completed clinical trials, we investigated the relationship between study characteristics and protocol deviations leading to the exclusion of subjects from Per Protocol Set (PPS) efficacy analysis. New drugs approved in Japan in the fiscal year 2014-2015 were targeted in the research. The reasons for excluding subjects from the PPS efficacy analysis were described in 102 trials out of 492 in the summary of new drug application documents, which was publicly disclosed after the drug's regulatory approval. The author extracted these reasons along with the numbers of the cases and the study characteristics of each clinical trial. Then, the direct comparison, univariate regression analysis, and multivariate regression analysis was carried out based on the exclusion rate. The study characteristics for which exclusion of subjects from the PPS efficacy analysis were frequently observed was multiregional clinical trials in study region; inhalant and external use in administration route; Anti-infective for systemic use; Respiratory system, Dermatologicals, and Nervous system in therapeutic drug under the Anatomical Therapeutic Chemical Classification. In the multivariate regression analysis, the clinical trial variables of inhalant, Respiratory system, or Dermatologicals were selected as study characteristics leading to a higher exclusion rate. The characteristics of the clinical trial that is likely to cause protocol deviations that will affect efficacy analysis were suggested. These studies should be considered for specific attention and priority observation in the trial protocol or its monitoring plan and execution, such as a clear description of inclusion/exclusion criteria in the protocol, development of training materials to site staff, and/or trial subjects as specific risk-alleviating measures.

  6. Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and Doffing.

    PubMed

    Kwon, Jennie H; Burnham, Carey-Ann D; Reske, Kimberly A; Liang, Stephen Y; Hink, Tiffany; Wallace, Meghan A; Shupe, Angela; Seiler, Sondra; Cass, Candice; Fraser, Victoria J; Dubberke, Erik R

    2017-09-01

    OBJECTIVE To evaluate healthcare worker (HCW) risk of self-contamination when donning and doffing personal protective equipment (PPE) using fluorescence and MS2 bacteriophage. DESIGN Prospective pilot study. SETTING Tertiary-care hospital. PARTICIPANTS A total of 36 HCWs were included in this study: 18 donned/doffed contact precaution (CP) PPE and 18 donned/doffed Ebola virus disease (EVD) PPE. INTERVENTIONS HCWs donned PPE according to standard protocols. Fluorescent liquid and MS2 bacteriophage were applied to HCWs. HCWs then doffed their PPE. After doffing, HCWs were scanned for fluorescence and swabbed for MS2. MS2 detection was performed using reverse transcriptase PCR. The donning and doffing processes were videotaped, and protocol deviations were recorded. RESULTS Overall, 27% of EVD PPE HCWs and 50% of CP PPE HCWs made ≥1 protocol deviation while donning, and 100% of EVD PPE HCWs and 67% of CP PPE HCWs made ≥1 protocol deviation while doffing (P=.02). The median number of doffing protocol deviations among EVD PPE HCWs was 4, versus 1 among CP PPE HCWs. Also, 15 EVD PPE protocol deviations were committed by doffing assistants and/or trained observers. Fluorescence was detected on 8 EVD PPE HCWs (44%) and 5 CP PPE HCWs (28%), most commonly on hands. MS2 was recovered from 2 EVD PPE HCWs (11%) and 3 CP PPE HCWs (17%). CONCLUSIONS Protocol deviations were common during both EVD and CP PPE doffing, and some deviations during EVD PPE doffing were committed by the HCW doffing assistant and/or the trained observer. Self-contamination was common. PPE donning/doffing are complex and deserve additional study. Infect Control Hosp Epidemiol 2017;38:1077-1083.

  7. Continuing oversight through site monitoring: experiences of an institutional ethics committee in an Indian tertiary-care hospital.

    PubMed

    Shetty, Yashashri C; Marathe, Padmaja; Kamat, Sandhya; Thatte, Urmila

    2012-01-01

    WHO-TDR and the Indian Council of Medical Research recommend site visits by institutional ethics committees (IECs) for continued oversight, to ensure the ethical conduct of research. Our IEC conducted seven site visits in 2008-2009 using a standardised format to monitor adherence to protocol and the informed consent process. The study identified issues related to informed consent (6/7), deviation from protocol (5/7), reporting of study progress to the IEC (3/7), recruiting additional participants without IEC approval (2/7), reporting of serious adverse events (1/7), investigator's lack of awareness of protocol and the informed consent document (2/7) and other findings. Investigators were informed about the findings and were asked to submit an explanation. The IEC issued warnings about not repeating such lapses in the future (5/7), restricted enrollment of new participants (2/7), recommended continued good clinical practice training to the study team (4/7), advised the recruitment of additional study coordinators (2/7), and requested the submission of adverse event reports (2/7) or sponsors' audit reports (2/7). Our study showed that the ethical conduct of studies can be ensured by conducting routine site monitoring.

  8. Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device.

    PubMed

    Umbrello, M; Salice, V; Spanu, P; Formenti, P; Barassi, A; Melzi d'Eril, G V; Iapichino, G

    2014-10-01

    The optimal level and modality of glucose control in critically ill patients is still debated. A protocolized approach and the use of nearly-continuous technologies are recommended to manage hyperglycemia, hypoglycemia and glycemic variability. We recently proposed a pato-physiology-based glucose control protocol which takes into account patient glucose/carbohydrate intake and insulin resistance. Aim of the present investigation was to assess the performance of our protocol with an automated intermittent plasma glucose monitoring device (OptiScanner™ 5000). OptiScanner™ was used in 6 septic patients, providing glucose measurement every 15' from a side-port of an indwelling central venous catheter. Target level of glucose was 80-150 mg/dL. Insulin infusion and kcal with nutritional support were also recorded. 6 septic patients were studied for 319 h (1277 measurements); 58 [45-65] hours for each patient (measurements/patient: 231 [172-265]). Blood glucose was at target for 93 [90-98]% of study time. Mean plasma glucose was 126 ± 11 mg/dL. Only 3 hypoglycemic episodes (78, 78, 69 mg/dL) were recorded. Glucose variability was limited: plasma glucose coefficient of variation was 11.7 ± 4.0% and plasma glucose standard deviation was 14.3 ± 5.5 mg/dL. The local glucose control protocol achieved satisfactory glucose control in septic patients along with a high degree of safeness. Automated intermittent plasma glucose monitoring seemed useful to assess the performance of the protocol. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  9. Influence of Noncompliance With Radiation Therapy Protocol Guidelines and Operative Bed Recurrences for Children With Rhabdomyosarcoma and Microscopic Residual Disease: A Report From the Children's Oncology Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Million, Lynn, E-mail: lynn.million@hci.utah.ed; Anderson, James; Breneman, John

    2011-06-01

    Purpose: Postoperative radiation therapy (RT) is recommended for patients with rhabdomyosarcoma having microscopic disease. Sometimes RT dose/volume is reduced or omitted in an attempt to avoid late effects, particularly in young children. We reviewed operative bed recurrences to determine if noncompliance with RT protocol guidelines influenced local-regional control. Methods and Materials: All operative bed recurrences among 695 Group II rhabdomyosarcoma patients in Intergroup Rhabdomyosarcoma Study Group (IRS) I through IV were reviewed for deviation from RT protocol. Major/minor dose deviation was defined as >10% or 6-10% of the prescribed dose (40-60 Gy), respectively. Major/minor volume deviation was defined as tumormore » excluded from the RT field or treatment volume not covered by the specified margin (preoperative tumor volume and 2- to 5-cm margin), respectively. No RT was a major deviation. Results: Forty-six of 83 (55%) patients with operative bed recurrences did not receive the intended RT (39 major and 7 minor deviations). RT omission was the most frequent RT protocol deviation (19/46, 41%), followed by dose (17/46, 37%), volume (9/46, 20%), and dose and volume deviation (1/46, 2%). Only 7 operative bed recurrences occurred in IRS IV (5% local-regional failure) with only 3 RT protocol deviations. Sixty-three (76%) patients with recurrence died of disease despite retrieval therapy, including 13 of 19 nonirradiated children. Conclusion: Over half of the operative bed recurrences were associated with noncompliance; omission of RT was the most common protocol deviation. Three fourths of children die when local-regional disease is not controlled, emphasizing the importance of RT in Group II rhabdomyosarcoma.« less

  10. SU-E-J-194: Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, E; Rioux, A; Benedict, S

    2015-06-15

    Purpose: Continuous monitoring of the SBRT lung patient motion during delivery is critical for ensuring adequate target volume margins in stereotactic body radiotherapy (SBRT). This work assesses the deviation of the patient surface motion using a real-time surface tracking system throughout treatment delivery. Methods: Our SBRT protocol employs abdominal compression to reduce the diaphragm movement to within 1 cm, and this is confirmed daily with fluoroscopy. Most patients are prescribed 3–5 fractions, and on treatment day a repeat motion analysis with fluoroscopy is performed, followed by a kV CBCT is aligned with the original planning CT image for 3D setupmore » confirmation. During this entire process a patient surface data restricted to whole chest or the sternum at the middle of the breathing cycle was captured using AlignRT optical surface tracking system and defined as a reference surface. For 10 patients, the deviation of the patient position from the reference surface was recorded during the SBRT delivery in the anterior-posterior (AP) direction at 3–6 measurements per second. Results: On average, the patient position deviated from the reference surface more than 4 mm, 3 mm and 2 mm in the AP direction for 0.95%, 3.7% and 11.1% of the total treatment time, respectively. Only one of the 10 patients showed that the maximum deviation of the patient surface during the SBRT delivery was greater than 1 cm. The average deviation of the patient surface from the reference surface during the SBRT delivery was not greater than 1.6 mm for any patient. Conclusion: This investigation indicates that AP motion can be significant even though the frequency is low. Continuous monitoring during SBRT has demonstrated value in monitoring patient motion ensuring that margins selected for SBRT are appropriate, and the use of non-ionizing and high-frequency imaging can provide useful indicators of motion during treatment.« less

  11. INVESTIGATING THE EFFICACY OF CLINICAL TRIAL MONITORING STRATEGIES: Design and Implementation of the Cluster Randomized START Monitoring Substudy

    PubMed Central

    Hullsiek, Katherine Huppler; Kagan, Jonathan M; Engen, Nicole; Grarup, Jesper; Hudson, Fleur; Denning, Eileen T; Carey, Catherine; Courtney-Rodgers, David; Finley, Elizabeth B; Jansson, Per O; Pearson, Mary T; Peavy, Dwight E; Belloso, Waldo H

    2014-01-01

    Background Trial monitoring protects participant safety and study integrity. While monitors commonly go on-site to verify source data, there is little evidence that this practice is efficient or effective. An ongoing international HIV treatment trial (START) provides an opportunity to explore the usefulness of different monitoring approaches. Methods All START sites are centrally monitored and required to follow a local monitoring plan requiring specific quality assurance activities. Additionally, sites were randomized (1:1) to receive, or not receive, annual on-site monitoring. The study will determine if on-site monitoring increases the identification of major protocol deviations (eligibility or consent violations, improper study drug use, primary or serious event underreporting, data alteration or fraud). Results The START study completed enrollment in December 2013, with planned follow-up through December 2016. The monitoring study is ongoing at 196 sites in 34 countries. Results are expected when the START study concludes in December 2016. PMID:25973346

  12. A Group Neighborhood Average Clock Synchronization Protocol for Wireless Sensor Networks

    PubMed Central

    Lin, Lin; Ma, Shiwei; Ma, Maode

    2014-01-01

    Clock synchronization is a very important issue for the applications of wireless sensor networks. The sensors need to keep a strict clock so that users can know exactly what happens in the monitoring area at the same time. This paper proposes a novel internal distributed clock synchronization solution using group neighborhood average. Each sensor node collects the offset and skew rate of the neighbors. Group averaging of offset and skew rate value are calculated instead of conventional point-to-point averaging method. The sensor node then returns compensated value back to the neighbors. The propagation delay is considered and compensated. The analytical analysis of offset and skew compensation is presented. Simulation results validate the effectiveness of the protocol and reveal that the protocol allows sensor networks to quickly establish a consensus clock and maintain a small deviation from the consensus clock. PMID:25120163

  13. A survey-based study on the protocols for therapeutic hypothermia in cardiac arrest patients in Korea: focusing on the differences between level 1 and 2 centers.

    PubMed

    Oh, Tae Gwan; Cha, Won Chul; Jo, Ik Joon; Kang, Mun Ju; Lee, Dong Woo

    2015-12-01

    We aimed to summarize the therapeutic hypothermia (TH) protocols used in emergency departments (EDs) in Korea and to investigate the differences between level 1 and 2 centers. The chief residents from 56 EDs were given a structured survey containing questions on the indications for TH, methods for TH induction, maintaining, and finalizing TH treatments. The participants were divided into 2 groups based on their work place (level 1 vs. level 2 centers). We received 36 responses to the survey. The majority of the participants (94.4%) reported that they routinely used TH. An average of 5.9 (standard deviation, 3.4) and 3.3 (standard deviation, 2.9) TH procedures were performed monthly in level 1 and 2 centers, respectively (P=0.01). The majority of level 1 and 2 centers (80.0% and 73.1%, respectively) had written TH protocols. Rectal (50.0%) and esophageal probes (38.9%) were most commonly used to monitor the patients' body temperatures. Midazolam (80.6%) and remifentanyl (47.2%) were the most commonly used sedatives. For TH induction, external cooling devices (77.8%) and cold saline infusion (66.1%) were predominant. Between level 1 and 2 centers, only the number of TH, the usage of remifentanyl, and application of external cooling device showed significant differences (P<0.05). Our study summarizes the TH protocols used in 36 EDs. The majority of study participants performed TH using a written protocol. We observed small number of differences in TH induction and maintenance methods between level 1 and 2 centers.

  14. Phase Transition in Protocols Minimizing Work Fluctuations

    NASA Astrophysics Data System (ADS)

    Solon, Alexandre P.; Horowitz, Jordan M.

    2018-05-01

    For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.

  15. Musical auditory stimulus acutely influences heart rate dynamic responses to medication in subjects with well-controlled hypertension.

    PubMed

    Martiniano, Eli Carlos; Santana, Milana Drumond Ramos; Barros, Érico Luiz Damasceno; do Socorro da Silva, Maria; Garner, David Matthew; de Abreu, Luiz Carlos; Valenti, Vitor E

    2018-01-17

    Music can improve the efficiency of medical treatment when correctly associated with drug action, reducing risk factors involving deteriorating cardiac function. We evaluated the effect of musical auditory stimulus associated with anti-hypertensive medication on heart rate (HR) autonomic control in hypertensive subjects. We evaluated 37 well-controlled hypertensive patients designated for anti-hypertensive medication. Heart rate variability (HRV) was calculated from the HR monitor recordings of two different, randomly sorted protocols (control and music) on two separate days. Patients were examined in a resting condition 10 minutes before medication and 20 minutes, 40 minutes and 60 minutes after oral medication. Music was played throughout the 60 minutes after medication with the same intensity for all subjects in the music protocol. We noted analogous response of systolic and diastolic arterial pressure in both protocols. HR decreased 60 minutes after medication in the music protocol while it remained unchanged in the control protocol. The effects of anti-hypertensive medication on SDNN (Standard deviation of all normal RR intervals), LF (low frequency, nu), HF (high frequency, nu) and alpha-1 scale were more intense in the music protocol. In conclusion, musical auditory stimulus increased HR autonomic responses to anti-hypertensive medication in well-controlled hypertensive subjects.

  16. Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Alfadda, Sara A; Ameen, Wadea; Hörmann, Romed; Puelacher, Wolfgang; Widmann, Gerlig

    2018-06-16

    To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol. A cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations. Based upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5. When MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.

  17. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.

    PubMed

    Altunkan, Sekip; Ilman, Nevzat; Kayatürk, Nur; Altunkan, Erkan

    2007-08-01

    Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. One hundred and twenty-one patients, older than 30 years of age, were studied and classified on the basis of the range of the International Protocol. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. A total of 33 participants were selected for each validation study. During the validation study, 99 measurements were performed on 33 participants for comparison. The first phase was performed on 15 participants, and if the device passed this phase, 18 more participants were selected. Having a two-fold purpose, this study was conducted on both adult and obese adult patients. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.1+/-4.0 mmHg for systolic BP (SBP) and -0.5+/-3.5 mmHg for diastolic BP (DBP) in the adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 88, 96, and 97 for SBP, and 88, 98, and 99 for DBP were <5, <10, and <15 mmHg, respectively. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.7+/-4.8 mmHg for SBP and -0.8+/-4.3 mmHg for DBP in the obese adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 82, 90, and 97 for SBP, and 80, 97, and 99 for DBP were <5, <10, and <15 mmHg, respectively. It was found that the Omron M6 automatic monitor, which measures BP at the upper arm, produced results in accordance with the criteria of phases 2.1 and 2.2 in both SBP and DBP, when applied to adults and to obese adults. It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.

  18. Monitoring of approved studies: A difficult tightrope walk by Ethics Committees.

    PubMed

    Davis, Sanish

    2018-01-01

    Continuing review of studies approved by the Ethics Committees (ECs) involves review of the progress of the study, annual reports, protocol deviations/violations, serious adverse event monitoring, and on-site monitoring. International and national regulations and guidelines for continuing review state that it is an opportunity for the EC to be assured that risks to subjects are minimized and is are reasonable in relation to anticipated benefits if any to the subjects and the knowledge it will generate. There are several barriers (e.g. lack of workforce, lack of training of members for conducting onsite review, and poor infrastructure) for ECs to do ongoing review of projects approved by them. Industry is an important stakeholder for the research enterprise in India and strongly advocates that ECs should at a minimum have pragmatic standard operating procedures for continuing review/monitoring of studies initially approved. ECs which deal with larger volume of studies with well-functioning secretariat, appropriately trained EC members and funding should definitely conduct onsite review/monitoring in addition to the ongoing review.

  19. Electronic protocol of respiratory physical therapy in patients with idiopathic adolescent scoliosis.

    PubMed

    Cano, Danila Vieira Baldini; Malafaia, Osvaldo; Alves, Vera Lúcia dos Santos; Avanzi, Osmar; Pinto, José Simão de Paula

    2011-01-01

    To create a clinical database of respiratory function in patients with adolescent idiopathic scoliosis; computerize and store this clinical data through the use of a software; incorporate this electronic protocol to the SINPE© (Integrated Electronic Protocols System) and analyze a pilot project with interpretation of results. From the literature review a computerized data bank of clinical data of postural deviations was set up (master protocol). Upon completion of the master protocol a specific protocol of respiratory function in patients with adolescent idiopathic scoliosis was designed and a pilot project was conducted to collect and analyze data from ten patients. It was possible to create the master protocol of postural deviations and the specific protocol of respiratory function in patients with adolescent idiopathic scoliosis. The data collected in the pilot project was processed by the SINPE ANALYZER©, generating charts and statistics. The establishment of the clinical database of adolescent idiopathic scoliosis was possible. Computerization and storage of clinical data using the software were viable. The electronic protocol of adolescent idiopathic scoliosis could be incorporated into the SINPE© and its use in the pilot project was successful.

  20. Handling of drug-related emergencies: an evaluation of emergency medical dispatch.

    PubMed

    Tonje, Lorem; Elisabeth, Saether; Lars, Wik

    2009-02-01

    Documenting the quality of emergency dispatch centres handling of emergency calls regarding intoxicated unconscious patients. Interview with eight emergency dispatch centre directors and a nationwide survey among 313 dispatchers in Norway were performed. In addition, a customized scoring system was used to evaluate dispatcher log recordings of real cases. The recordings were compared with information from corresponding ambulance records. Ninety-nine percent of the dispatchers stated that they used the Norwegian protocol for medical emergencies and 89% of them found it useful. The interviews, the survey, and the recordings, however, documented frequent deviation from the protocol. This instructs ambulance dispatch for any unconscious patient, but 21% stated that they would not dispatch any resource for an unconscious patient without further survey in alcohol-related cases. This was significantly more often (P<0.05) than for the narcotic, combination and prescription - drug-related cases with 4, 10 and 7%, respectively. The recordings revealed deviation from the protocol with dispatchers only determining the patients' level of consciousness and respiratory status in 64 and 70% of the cases, respectively. For 16% of the cases, the dispatcher did not ask the caller about consciousness at all, even though these patients later were found with reduced consciousness. On the basis of the interviews and the survey, cases were handled according to guidelines. The log recordings, however, disclosed deviation from the protocol. Alcohol intoxication was associated with higher rate of deviation from the protocol compared with other intoxications.

  1. Current fluctuations in periodically driven systems

    NASA Astrophysics Data System (ADS)

    Barato, Andre C.; Chetrite, Raphael

    2018-05-01

    Small nonequelibrium systems driven by an external periodic protocol can be described by Markov processes with time-periodic transition rates. In general, current fluctuations in such small systems are large and may play a crucial role. We develop a theoretical formalism to evaluate the rate of such large deviations in periodically driven systems. We show that the scaled cumulant generating function that characterizes current fluctuations is given by a maximal Floquet exponent. Comparing deterministic protocols with stochastic protocols, we show that, with respect to large deviations, systems driven by a stochastic protocol with an infinitely large number of jumps are equivalent to systems driven by deterministic protocols. Our results are illustrated with three case studies: a two-state model for a heat engine, a three-state model for a molecular pump, and a biased random walk with a time-periodic affinity.

  2. A randomized controlled trial investigating the effects of craniosacral therapy on pain and heart rate variability in fibromyalgia patients.

    PubMed

    Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen

    2011-01-01

    Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.

  3. TU-G-BRD-04: A Round Robin Dosimetry Intercomparison of Gamma Stereotactic Radiosurgery Calibration Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R; Alvarez, P; Bednarz, G

    2015-06-15

    Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.« less

  4. Using principal component analysis for selecting network behavioral anomaly metrics

    NASA Astrophysics Data System (ADS)

    Gregorio-de Souza, Ian; Berk, Vincent; Barsamian, Alex

    2010-04-01

    This work addresses new approaches to behavioral analysis of networks and hosts for the purposes of security monitoring and anomaly detection. Most commonly used approaches simply implement anomaly detectors for one, or a few, simple metrics and those metrics can exhibit unacceptable false alarm rates. For instance, the anomaly score of network communication is defined as the reciprocal of the likelihood that a given host uses a particular protocol (or destination);this definition may result in an unrealistically high threshold for alerting to avoid being flooded by false positives. We demonstrate that selecting and adapting the metrics and thresholds, on a host-by-host or protocol-by-protocol basis can be done by established multivariate analyses such as PCA. We will show how to determine one or more metrics, for each network host, that records the highest available amount of information regarding the baseline behavior, and shows relevant deviances reliably. We describe the methodology used to pick from a large selection of available metrics, and illustrate a method for comparing the resulting classifiers. Using our approach we are able to reduce the resources required to properly identify misbehaving hosts, protocols, or networks, by dedicating system resources to only those metrics that actually matter in detecting network deviations.

  5. Efficiency and large deviations in time-asymmetric stochastic heat engines

    DOE PAGES

    Gingrich, Todd R.; Rotskoff, Grant M.; Vaikuntanathan, Suriyanarayanan; ...

    2014-10-24

    In a stochastic heat engine driven by a cyclic non-equilibrium protocol, fluctuations in work and heat give rise to a fluctuating efficiency. Using computer simulations and tools from large deviation theory, we have examined these fluctuations in detail for a model two-state engine. We find in general that the form of efficiency probability distributions is similar to those described by Verley et al (2014 Nat. Commun. 5 4721), in particular featuring a local minimum in the long-time limit. In contrast to the time-symmetric engine protocols studied previously, however, this minimum need not occur at the value characteristic of a reversible Carnot engine. Furthermore, while the local minimum may reside at the global minimum of a large deviation rate function, it does not generally correspond to the least likely efficiency measured over finite time. Lastly, we introduce a general approximation for the finite-time efficiency distribution,more » $$P(\\eta )$$, based on large deviation statistics of work and heat, that remains very accurate even when $$P(\\eta )$$ deviates significantly from its large deviation form.« less

  6. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients.

    PubMed

    Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan

    2008-04-01

    Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.

  7. Improving the quality of child anthropometry: Manual anthropometry in the Body Imaging for Nutritional Assessment Study (BINA).

    PubMed

    Conkle, Joel; Ramakrishnan, Usha; Flores-Ayala, Rafael; Suchdev, Parminder S; Martorell, Reynaldo

    2017-01-01

    Anthropometric data collected in clinics and surveys are often inaccurate and unreliable due to measurement error. The Body Imaging for Nutritional Assessment Study (BINA) evaluated the ability of 3D imaging to correctly measure stature, head circumference (HC) and arm circumference (MUAC) for children under five years of age. This paper describes the protocol for and the quality of manual anthropometric measurements in BINA, a study conducted in 2016-17 in Atlanta, USA. Quality was evaluated by examining digit preference, biological plausibility of z-scores, z-score standard deviations, and reliability. We calculated z-scores and analyzed plausibility based on the 2006 WHO Child Growth Standards (CGS). For reliability, we calculated intra- and inter-observer Technical Error of Measurement (TEM) and Intraclass Correlation Coefficient (ICC). We found low digit preference; 99.6% of z-scores were biologically plausible, with z-score standard deviations ranging from 0.92 to 1.07. Total TEM was 0.40 for stature, 0.28 for HC, and 0.25 for MUAC in centimeters. ICC ranged from 0.99 to 1.00. The quality of manual measurements in BINA was high and similar to that of the anthropometric data used to develop the WHO CGS. We attributed high quality to vigorous training, motivated and competent field staff, reduction of non-measurement error through the use of technology, and reduction of measurement error through adequate monitoring and supervision. Our anthropometry measurement protocol, which builds on and improves upon the protocol used for the WHO CGS, can be used to improve anthropometric data quality. The discussion illustrates the need to standardize anthropometric data quality assessment, and we conclude that BINA can provide a valuable evaluation of 3D imaging for child anthropometry because there is comparison to gold-standard, manual measurements.

  8. Setup deviations for whole-breast radiotherapy with TomoDirect: A comparison of weekly and biweekly image-guided protocols

    NASA Astrophysics Data System (ADS)

    Jung, Jae Hong; Jung, Joo-Young; Bae, Sun Hyun; Moon, Seong Kwon; Cho, Kwang Hwan

    2016-10-01

    The purpose of this study was to compare patient setup deviations for different image-guided protocols (weekly vs. biweekly) that are used in TomoDirect three-dimensional conformal radiotherapy (TD-3DCRT) for whole-breast radiation therapy (WBRT). A total of 138 defined megavoltage computed tomography (MVCT) image sets from 46 breast cancer cases were divided into two groups based on the imaging acquisition times: weekly or biweekly. The mean error, three-dimensional setup displacement error (3D-error), systematic error (Σ), and random error (σ) were calculated for each group. The 3D-errors were 4.29 ± 1.11 mm and 5.02 ± 1.85 mm for the weekly and biweekly groups, respectively; the biweekly error was 14.6% higher than the weekly error. The systematic errors in the roll angle and the x, y, and z directions were 0.48°, 1.72 mm, 2.18 mm, and 1.85 mm for the weekly protocol and 0.21°, 1.24 mm, 1.39 mm, and 1.85 mm for the biweekly protocol. Random errors in the roll angle and the x, y, and z directions were 25.7%, 40.6%, 40.0%, and 40.8% higher in the biweekly group than in the weekly group. For the x, y, and z directions, the distributions of the treatment frequency at less than 5 mm were 98.6%, 91.3%, and 94.2% in the weekly group and 94.2%, 89.9%, and 82.6% in the biweekly group. Moreover, the roll angles with 0 - 1° were 79.7% and 89.9% in the weekly and the biweekly groups, respectively. Overall, the evaluation of setup deviations for the two protocols revealed no significant differences (p > 0.05). Reducing the frequency of MVCT imaging could have promising effects on imaging doses and machine times during treatment. However, the biweekly protocol was associated with increased random setup deviations in the treatment. We have demonstrated a biweekly protocol of TD-3DCRT for WBRT, and we anticipate that our method may provide an alternative approach for considering the uncertainties in the patient setup.

  9. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer

    PubMed Central

    Wootton, Landon; Kudchadker, Rajat; Lee, Andrew; Beddar, Sam

    2014-01-01

    We designed and constructed an in vivo dosimetry system using plastic scintillation detectors (PSDs) to monitor dose to the rectal wall in patients undergoing intensity-modulated radiation therapy for prostate cancer. Five patients were enrolled in an Institutional Review Board–approved protocol for twice weekly in vivo dose monitoring with our system, resulting in a total of 142 in vivo dose measurements. PSDs were attached to the surface of endorectal balloons used for prostate immobilization to place the PSDs in contact with the rectal wall. Absorbed dose was measured in real time and the total measured dose was compared with the dose calculated by the treatment planning system on the daily CT image dataset. The mean difference between measured and calculated doses for the entire patient population was −0.4% (standard deviation 2.8%). The mean difference between daily measured and calculated doses for each patient ranged from −3.3% to 3.3% (standard deviation ranged from 5.6% to 7.1% for 4 patients and was 14.0% for the last, for whom optimal positioning of the detector was difficult owing to the patient’s large size). Patients tolerated the detectors well and the treatment workflow was not compromised. Overall, PSDs performed well as in vivo dosimeters, providing excellent accuracy, real-time measurement, and reusability. PMID:24434775

  10. Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer

    NASA Astrophysics Data System (ADS)

    Wootton, Landon; Kudchadker, Rajat; Lee, Andrew; Beddar, Sam

    2014-02-01

    We designed and constructed an in vivo dosimetry system using plastic scintillation detectors (PSDs) to monitor dose to the rectal wall in patients undergoing intensity-modulated radiation therapy for prostate cancer. Five patients were enrolled in an Institutional Review Board-approved protocol for twice weekly in vivo dose monitoring with our system, resulting in a total of 142 in vivo dose measurements. PSDs were attached to the surface of endorectal balloons used for prostate immobilization to place the PSDs in contact with the rectal wall. Absorbed dose was measured in real time and the total measured dose was compared with the dose calculated by the treatment planning system on the daily computed tomographic image dataset. The mean difference between measured and calculated doses for the entire patient population was -0.4% (standard deviation 2.8%). The mean difference between daily measured and calculated doses for each patient ranged from -3.3% to 3.3% (standard deviation ranged from 5.6% to 7.1% for four patients and was 14.0% for the last, for whom optimal positioning of the detector was difficult owing to the patient's large size). Patients tolerated the detectors well and the treatment workflow was not compromised. Overall, PSDs performed well as in vivo dosimeters, providing excellent accuracy, real-time measurement and reusability.

  11. Performance of the Colson MAM BP 3AA1-2 automatic blood pressure monitor according to the European Society of Hypertension validation protocol.

    PubMed

    Pereira, Telmo; Maldonado, João

    2005-11-01

    To evaluate the performance of the Colson MAM BP 3AA1-2 oscillometric automatic blood pressure monitor according to the validation protocol of the European Society of Hypertension, testing its suitability for self-measurement of blood pressure. The performance of the device was assessed in relation to various clinical variables, including age, gender, body mass index, arm circumference and arterial stiffness. 33 subjects (15 men and 18 women), with a mean age of 47 +/- 10 years, were studied according to the procedures laid down in the European Society of Hypertension validation protocol. Sequential same-arm blood pressure measurements were made, alternating between a mercury standard and the automatic device. The differences among the test-control measurements were assessed and divided into categorization zones of 5, 10 and 15 mmHg discrepancy. Aortic pulse wave velocity was assessed in all subjects with a Complior device (Colson, Paris). The Colson MAM BP 3AA1-2 passed all three phases of the protocol for both systolic and diastolic blood pressure. The mean differences between the test and control measurements were -1.0 +/- 5.0 mmHg for systolic blood pressure and -1.1 +/- 4.1 mmHg for diastolic blood pressure. Both standard deviations are well below the 8 mmHg limit proposed by the Association for the Advancement of Medical Instrumentation. The predictive value of various clinical variables for the discrepancies was assessed by a regression model analysis, with no variable being found that independently undermined the performance of the monitor. In another regression analysis, we found a similar relation between test and control blood pressures and aortic pulse wave velocity, a widely recognized and validated index of target organ damage. These data show that the Colson MAM BP 3AA1-2 satisfies the quality requirements proposed by the European Society of Hypertension, demonstrating its suitability for inclusion in integrated programs of clinical surveillance based on self-measurement of blood pressure. The uniformity of its performance over a wide spectrum of clinical characteristics and the relation found with pulse wave velocity further reinforce its clinical validity.

  12. Ecological quality boundary-setting procedures: the Gulf of Riga case study.

    PubMed

    Aigars, Juris; Müller-Karulis, Bärbel; Martin, Georg; Jermakovs, Vadims

    2008-03-01

    Two approaches for setting ecological class boundaries, response curves and a simplified mathematical boundary-setting protocol, were tested for coastal, transitional and open waters in the Gulf of Riga, Baltic Sea. The simplified mathematical boundary-setting protocol defines acceptable ecological status based on expert judgment by a uniform relative deviation from reference conditions. In contrast, response curves derive class boundary definitions from observed changes in biological quality elements along environmental pressure gradients for class boundary definitions. Identification of relevant environmental pressures for the construction of response curves was based on a conceptual model of eutrophication in the Gulf of Riga. Response curves were successfully established for summer chlorophyll a and transparency, as well as for macrozoobenthos abundance in the Central Gulf, macrozoobenthos biotic coefficient in the Southern Gulf, and maximum depth of phytobenthos in the Northern Gulf. In the Gulf of Riga response curves almost always permitted a larger deviation from reference conditions than the 50% deviation applied for the simplified mathematical boundary-setting protocol. The case study clearly demonstrated that class boundary definitions should take into account the sensitivity of the target water body. Also, the class boundaries for different ecological quality elements were internally more consistent than those derived by the simplified mathematical boundary-setting protocol.

  13. Voice deviation, dysphonia risk screening and quality of life in individuals with various laryngeal diagnoses

    PubMed Central

    Nemr, Katia; Cota, Ariane; Tsuji, Domingos; Simões-Zenari, Marcia

    2018-01-01

    OBJECTIVES: To characterize the voice quality of individuals with dysphonia and to investigate possible correlations between the degree of voice deviation (D) and scores on the Dysphonia Risk Screening Protocol-General (DRSP), the Voice-Related Quality of Life (V-RQOL) measure and the Voice Handicap Index, short version (VHI-10). METHODS: The sample included 200 individuals with dysphonia. Following laryngoscopy, the participants completed the DRSP, the V-RQOL measure, and the VHI-10; subsequently, voice samples were recorded for auditory-perceptual and acoustic analyses. The correlation between the score for each questionnaire and the overall degree of vocal deviation was analyzed, as was the correlation among the scores for the three questionnaires. RESULTS: Most of the participants (62%) were female, and the mean age of the sample was 49 years. The most common laryngeal diagnosis was organic dysphonia (79.5%). The mean D was 59.54, and the predominance of roughness had a mean of 54.74. All the participants exhibited at least one abnormal acoustic aspect. The mean questionnaire scores were DRSP, 44.7; V-RQOL, 57.1; and VHI-10, 16. An inverse correlation was found between the V-RQOL score and D; however, a positive correlation was found between both the VHI-10 and DRSP scores and D. CONCLUSION: A predominance of adult women, organic dysphonia, moderate voice deviation, high dysphonia risk, and low to moderate quality of life impact characterized our sample. There were correlations between the scores of each of the three questionnaires and the degree of voice deviation. It should be noted that the DRSP monitored the degree of dysphonia severity, which reinforces its applicability for patients with different laryngeal diagnoses. PMID:29538494

  14. Voice deviation, dysphonia risk screening and quality of life in individuals with various laryngeal diagnoses.

    PubMed

    Nemr, Katia; Cota, Ariane; Tsuji, Domingos; Simões-Zenari, Marcia

    2018-03-12

    To characterize the voice quality of individuals with dysphonia and to investigate possible correlations between the degree of voice deviation (D) and scores on the Dysphonia Risk Screening Protocol-General (DRSP), the Voice-Related Quality of Life (V-RQOL) measure and the Voice Handicap Index, short version (VHI-10). The sample included 200 individuals with dysphonia. Following laryngoscopy, the participants completed the DRSP, the V-RQOL measure, and the VHI-10; subsequently, voice samples were recorded for auditory-perceptual and acoustic analyses. The correlation between the score for each questionnaire and the overall degree of vocal deviation was analyzed, as was the correlation among the scores for the three questionnaires. Most of the participants (62%) were female, and the mean age of the sample was 49 years. The most common laryngeal diagnosis was organic dysphonia (79.5%). The mean D was 59.54, and the predominance of roughness had a mean of 54.74. All the participants exhibited at least one abnormal acoustic aspect. The mean questionnaire scores were DRSP, 44.7; V-RQOL, 57.1; and VHI-10, 16. An inverse correlation was found between the V-RQOL score and D; however, a positive correlation was found between both the VHI-10 and DRSP scores and D. A predominance of adult women, organic dysphonia, moderate voice deviation, high dysphonia risk, and low to moderate quality of life impact characterized our sample. There were correlations between the scores of each of the three questionnaires and the degree of voice deviation. It should be noted that the DRSP monitored the degree of dysphonia severity, which reinforces its applicability for patients with different laryngeal diagnoses.

  15. A nurse-guided, basal-prandial insulin treatment protocol for achieving glycaemic control of hospitalized, non-critically ill diabetes patients, is non-inferior to physician-guided therapy: A pivotal, nurse-empowerment study.

    PubMed

    Segal, Gad; Karniel, Eli; Mahagna, Ahmed; Kaa'dan, Fadi; Levi, Zehava; Balik, Chaya

    2015-12-01

    Basal-prandial insulin is established for glycaemic control for hospitalized, type 2 diabetes patients. Empowering nurses to guide such protocols could be advantageous.The study aims to comparatively assess the efficacy and safety of glycaemic control by a nurse-guided protocol with physician-guided therapy. It also aims to assess the impact of empowerment on the nurses' sense of competence. This is a prospective, controlled, randomized, single-blinded study. Validated protocol utilizing basal-prandial insulin was used. Glycaemic control was the primary efficacy outcome, whereas hypoglycaemia and laboratory parameters were followed for safety. Assessment of nurses' psychological empowerment was done. One hundred fifty-eight treatment days of 53 patients were included. Patients were randomized to either study group (n = 27) or control group (n = 26). Glycaemia deviation from liberal range (60-300 mg/dL) was 7.4% of days for nurse-guided, basal-prandial insulin treatment protocol (NGP) and 7.84% for physician-guided therapy (PGT), P = 0.901. Rate of glycaemia deviation from the strict range (100-180 mg/dL) was 49.76% for NGP and 47.38% for PGT, P = 0.703. Mean range of daily deviation was similar (77.05 mg/dL for NGP and 76.04 mg/dL for PGT, P = 0.93). There were no significant differences in safety parameters. An empowerment questionnaire showed tendency for increased nurses' sense of competence. Nurse-guided protocol is non-inferior to physician-guided treatment in efficacy and safety parameters. Nurses' sense of competence was positively influenced. © 2014 Wiley Publishing Asia Pty Ltd.

  16. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong

    2011-08-01

    The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.

  17. Dose specification and quality assurance of RTOG protocol 95-17; a cooperative group study of 192Ir breast implants as sole therapy

    PubMed Central

    Ibbott, Geoffrey S.; Hanson, W.F.; Martin, Elizabeth; Kuske, Robert R.; Arthur, Douglas; Rabinovitch, Rachel; White, Julia; Wilenzick, Raymond M.; Harris, Irene; Tailor, Ramesh C.

    2007-01-01

    Purpose RTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast carcinoma following breast conserving surgery. Low or high dose rate sources were allowed. Dose prescription and treatment evaluation were based on recommendations in ICRU Report 58, and included the parameters mean central dose (MCD), average peripheral dose, dose homogeneity index (DHI), and the dimensions of the low and high dose regions. Methods and Materials Three levels of quality assurance were implemented: (1) Credentialing of institutions was required prior to entering patients onto the study. (2) Rapid review of each treatment plan was conducted prior to treatment, and (3) Retrospective review was performed by the Radiological Physics Center in conjunction with the study chairman and RTOG dosimetry staff. Results Credentialing focused on the accuracy of dose calculation algorithm and compliance with protocol guidelines. Rapid review was designed to identify and correct deviations from the protocol prior to treatment. The retrospective review involved recalculation of dosimetry parameters and review of dose distributions to evaluate the treatment. Specifying both central and peripheral doses resulted in uniform dose distributions, with a mean dose homogeneity index of 0.83 ±0.06. Conclusions Vigorous quality assurance resulted in a high-quality study with few deviations; only 4 of 100 patients were judged as minor variations from protocol and no patient was judged a major deviation. This study should be considered a model for quality assurance of future trials. PMID:18035213

  18. Improving the quality of child anthropometry: Manual anthropometry in the Body Imaging for Nutritional Assessment Study (BINA)

    PubMed Central

    2017-01-01

    Anthropometric data collected in clinics and surveys are often inaccurate and unreliable due to measurement error. The Body Imaging for Nutritional Assessment Study (BINA) evaluated the ability of 3D imaging to correctly measure stature, head circumference (HC) and arm circumference (MUAC) for children under five years of age. This paper describes the protocol for and the quality of manual anthropometric measurements in BINA, a study conducted in 2016–17 in Atlanta, USA. Quality was evaluated by examining digit preference, biological plausibility of z-scores, z-score standard deviations, and reliability. We calculated z-scores and analyzed plausibility based on the 2006 WHO Child Growth Standards (CGS). For reliability, we calculated intra- and inter-observer Technical Error of Measurement (TEM) and Intraclass Correlation Coefficient (ICC). We found low digit preference; 99.6% of z-scores were biologically plausible, with z-score standard deviations ranging from 0.92 to 1.07. Total TEM was 0.40 for stature, 0.28 for HC, and 0.25 for MUAC in centimeters. ICC ranged from 0.99 to 1.00. The quality of manual measurements in BINA was high and similar to that of the anthropometric data used to develop the WHO CGS. We attributed high quality to vigorous training, motivated and competent field staff, reduction of non-measurement error through the use of technology, and reduction of measurement error through adequate monitoring and supervision. Our anthropometry measurement protocol, which builds on and improves upon the protocol used for the WHO CGS, can be used to improve anthropometric data quality. The discussion illustrates the need to standardize anthropometric data quality assessment, and we conclude that BINA can provide a valuable evaluation of 3D imaging for child anthropometry because there is comparison to gold-standard, manual measurements. PMID:29240796

  19. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  20. Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH.

    PubMed

    Galdino, Flávia E; Smith, Jamie P; Kwamou, Sophie I; Kampouris, Dimitrios K; Iniesta, Jesus; Smith, Graham C; Bonacin, Juliano A; Banks, Craig E

    2015-12-01

    A reagentless pH sensor based upon disposable and economical graphite screen-printed electrodes (GSPEs) is demonstrated for the first time. The voltammetric pH sensor utilizes GSPEs which are chemically pretreated to form surface immobilized oxygenated species that, when their redox behavior is monitored, give a Nernstian response over a large pH range (1-13). An excellent experimental correlation is observed between the voltammetric potential and pH over the entire pH range of 1-13 providing a simple approach with which to monitor solution pH. Such a linear response over this dynamic pH range is not usually expected but rather deviation from linearity is encountered at alkaline pH values; absence of this has previously been attributed to a change in the pKa value of surface immobilized groups from that of solution phase species. This non-deviation, which is observed here in the case of our facile produced reagentless pH sensor and also reported in the literature for pH sensitive compounds immobilized upon carbon electrodes/surfaces, where a linear response is observed over the entire pH range, is explained alternatively for the first time. The performance of the GSPE pH sensor is also directly compared with a glass pH probe and applied to the measurement of pH in "real" unbuffered samples where an excellent correlation between the two protocols is observed validating the proposed GSPE pH sensor.

  1. Radiotherapy quality assurance report from children's oncology group AHOD0031

    PubMed Central

    Dharmarajan, Kavita V.; Friedman, Debra L.; FitzGerald, T.J.; McCarten, Kathleen M.; Constine, Louis S.; Chen, Lu; Kessel, Sandy K.; Iandoli, Matt; Laurie, Fran; Schwartz, Cindy L.; Wolden, Suzanne L.

    2016-01-01

    Purpose A phase III trial assessing response-based therapy in intermediate-risk Hodgkin lymphoma, mandated real-time central review of involved field radiotherapy and imaging records by a centralized review center to maximize protocol compliance. We report the impact of centralized radiotherapy review upon protocol compliance. Methods Review of simulation films, port films, and dosimetry records was required pre-treatment and after treatment completion. Records were reviewed by study-affiliated or review center-affiliated radiation oncologists. A 6–10% deviation from protocol-specified dose was scored as “minor”; >10% was “major”. A volume deviation was scored as “minor” if margins were less than specified, or “major” if fields transected disease-bearing areas. Interventional review and final compliance review scores were assigned to each radiotherapy case and compared. Results Of 1712 patients enrolled, 1173 underwent IFRT at 256 institutions in 7 countries. An interventional review was performed in 88% and a final review in 98%. Overall, minor and major deviations were found in 12% and 6%, respectively. Among the cases for which ≥ 1 pre-IFRT modification was requested by QARC and subsequently made by the treating institution, 100% were made compliant on final review. In contrast, among the cases for which ≥ 1 modification was requested but not made by the treating institution, 10% were deemed compliant on final review. Conclusion In a large trial with complex treatment pathways and heterogeneous radiotherapy fields, central review was performed in a large percentage of cases pre-IFRT and identified frequent potential deviations in a timely manner. When suggested modifications were performed by the institutions, deviations were almost eliminated. PMID:25670539

  2. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant.

    PubMed

    Moreno-Garcia, Isabel M; Palacios-Garcia, Emilio J; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J; Varo-Martinez, Marta; Real-Calvo, Rafael J

    2016-05-26

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant's components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid.

  3. [Importance of clinical trial design and standardized implementation in ophthalmology].

    PubMed

    Xu, Xun

    2013-06-01

    Clinical trial is an important medical research method, as well as the bridge of translational medicine. The results of scientific evidences are useful to make clinical practice guidelines. At present,much experience of carrying out ophthalmology clinical trials has been obtained and achieved, but there are still some scientific, practical and ethical problems to be solved,because of their impact on the authenticity and reliability of the results. Therefore, attaching great importance to design of the clinical research and implement of the standardization would be the goal and the development direction. Clinical trial design rely on objective, follow international design principles on the ethics,randomization, blinding and placebo setting. During the trial implementation, personnel training,project management and monitoring would help to reduce protocol deviation and ensure data authenticity.

  4. An "Off-the-Shelf" System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy.

    PubMed

    Neal, Robert E; Kavnoudias, Helen; Thomson, Kenneth R

    2015-06-01

    Irreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators. We describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator. Accuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues. This system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents-sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

  5. Combining accuracy assessment of land-cover maps with environmental monitoring programs

    USGS Publications Warehouse

    Stehman, S.V.; Czaplewski, R.L.; Nusser, S.M.; Yang, L.; Zhu, Z.

    2000-01-01

    A scientifically valid accuracy assessment of a large-area, land-cover map is expensive. Environmental monitoring programs offer a potential source of data to partially defray the cost of accuracy assessment while still maintaining the statistical validity. In this article, three general strategies for combining accuracy assessment and environmental monitoring protocols are described. These strategies range from a fully integrated accuracy assessment and environmental monitoring protocol, to one in which the protocols operate nearly independently. For all three strategies, features critical to using monitoring data for accuracy assessment include compatibility of the land-cover classification schemes, precisely co-registered sample data, and spatial and temporal compatibility of the map and reference data. Two monitoring programs, the National Resources Inventory (NRI) and the Forest Inventory and Monitoring (FIM), are used to illustrate important features for implementing a combined protocol.

  6. Channel Deviation-Based Power Control in Body Area Networks.

    PubMed

    Van, Son Dinh; Cotton, Simon L; Smith, David B

    2018-05-01

    Internet enabled body area networks (BANs) will form a core part of future remote health monitoring and ambient assisted living technology. In BAN applications, due to the dynamic nature of human activity, the off-body BAN channel can be prone to deep fading caused by body shadowing and multipath fading. Using this knowledge, we present some novel practical adaptive power control protocols based on the channel deviation to simultaneously prolong the lifetime of wearable devices and reduce outage probability. The proposed schemes are both flexible and relatively simple to implement on hardware platforms with constrained resources making them inherently suitable for BAN applications. We present the key algorithm parameters used to dynamically respond to the channel variation. This allows the algorithms to achieve a better energy efficiency and signal reliability in everyday usage scenarios such as those in which a person undertakes many different activities (e.g., sitting, walking, standing, etc.). We also profile their performance against traditional, optimal, and other existing schemes for which it is demonstrated that not only does the outage probability reduce significantly, but the proposed algorithms also save up to average transmit power compared to the competing schemes.

  7. Recommended features of protocols for long-term ecological monitoring

    USGS Publications Warehouse

    Oakley, Karen L.; Boudreau, Susan L.; Humphrey, Sioux-Z

    2001-01-01

    In 1991, the National Park Service (NPS) selected seven parks to serve as prototypes for development of a long-term ecological monitoring program. Denali National Park and Preserve was one of the prototype parks selected. The principal focus of this national program was to detect and document resource changes and to understand the forces driving those changes. One of the major tasks of each prototype park was to develop monitoring protocols. In this paper, we discuss some lessons learned and what we believe to be the most important features of protocols.One of the many lessons we have learned is that monitoring protocols vary greatly in content and format. This variation leads to confusion about what information protocols should contain and how they should be formatted. Problems we have observed in existing protocols include (1) not providing enough detail, (2) omitting critical topics (such as data management), and (3) mixing explanation with instructions. Once written, protocols often sit on the shelf to collect dust, allowing methods changes to occur without being adequately considered, tested, or documented. Because a lengthy and costly research effort is often needed to develop protocols, a vision of what the final product should look like is helpful. Based on our involvement with the prototype monitoring program for Denali (Oakley and Boudreau 2000), we recommend key features of protocols, including a scheme for linking protocols to data in the data management system and for tracking protocol revisions. A protocol system is crucial for producing long-term data sets of known quality that meet program objectives.

  8. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of the landfill monitoring and SSM plan requirements, deviations include the items in paragraphs (a.... (c) A deviation occurs when a SSM plan is not developed or maintained on site. [68 FR 2238, Jan. 16...

  9. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the landfill monitoring and SSM plan requirements, deviations include the items in paragraphs (a.... (c) A deviation occurs when a SSM plan is not developed or maintained on site. [68 FR 2238, Jan. 16...

  10. Automated monitoring of medical protocols: a secure and distributed architecture.

    PubMed

    Alsinet, T; Ansótegui, C; Béjar, R; Fernández, C; Manyà, F

    2003-03-01

    The control of the right application of medical protocols is a key issue in hospital environments. For the automated monitoring of medical protocols, we need a domain-independent language for their representation and a fully, or semi, autonomous system that understands the protocols and supervises their application. In this paper we describe a specification language and a multi-agent system architecture for monitoring medical protocols. We model medical services in hospital environments as specialized domain agents and interpret a medical protocol as a negotiation process between agents. A medical service can be involved in multiple medical protocols, and so specialized domain agents are independent of negotiation processes and autonomous system agents perform monitoring tasks. We present the detailed architecture of the system agents and of an important domain agent, the database broker agent, that is responsible of obtaining relevant information about the clinical history of patients. We also describe how we tackle the problems of privacy, integrity and authentication during the process of exchanging information between agents.

  11. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Pesticide Factsheets

    EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.

  12. Comparison of the Quantiplex Version 3.0 Assay and a Sensitized Amplicor Monitor Assay for Measurement of Human Immunodeficiency Virus Type 1 RNA Levels in Plasma Samples

    PubMed Central

    Highbarger, Helene C.; Alvord, W. Gregory; Jiang, Min Kang; Shah, Akram S.; Metcalf, Julia A.; Lane, H. Clifford; Dewar, Robin L.

    1999-01-01

    This study evaluated correlation and agreement between version 3 of the Quantiplex human immunodeficiency virus type 1 (HIV-1) RNA assay (v3 branched DNA [bDNA]) and a sensitized Amplicor HIV-1 Monitor assay (reverse transcription [RT]-PCR) for the measurement of HIV RNA. Three hundred eighteen samples from 59 randomly selected, HIV-1-seropositive persons on various drug protocols from the National Institute of Allergy and Infectious Diseases HIV outpatient clinic were studied. The results indicate that v3 bDNA and RT-PCR are highly correlated (r = 0.98) and are in good agreement (mean difference in log10 copies/ml ± 2 standard deviations = 0.072 ± 0.371). The relationship between values obtained by both assays is given by the following equation: log10v3 bDNA = −0.0915 + 1.0052 · log10RT-PCR. This represents a 1.026-fold difference between log10RT-PCR values and log10v3 bDNA values. PMID:10523562

  13. Design, implementation and multisite evaluation of a system suitability protocol for the quantitative assessment of instrument performance in liquid chromatography-multiple reaction monitoring-MS (LC-MRM-MS).

    PubMed

    Abbatiello, Susan E; Mani, D R; Schilling, Birgit; Maclean, Brendan; Zimmerman, Lisa J; Feng, Xingdong; Cusack, Michael P; Sedransk, Nell; Hall, Steven C; Addona, Terri; Allen, Simon; Dodder, Nathan G; Ghosh, Mousumi; Held, Jason M; Hedrick, Victoria; Inerowicz, H Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S; Riley, C Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H; Buck, Charles; Fisher, Susan J; Gibson, Bradford W; Liebler, Daniel; Maccoss, Michael; Neubert, Thomas A; Paulovich, Amanda; Regnier, Fred; Skates, Steven J; Tempst, Paul; Wang, Mu; Carr, Steven A

    2013-09-01

    Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.

  14. Design, Implementation and Multisite Evaluation of a System Suitability Protocol for the Quantitative Assessment of Instrument Performance in Liquid Chromatography-Multiple Reaction Monitoring-MS (LC-MRM-MS)*

    PubMed Central

    Abbatiello, Susan E.; Mani, D. R.; Schilling, Birgit; MacLean, Brendan; Zimmerman, Lisa J.; Feng, Xingdong; Cusack, Michael P.; Sedransk, Nell; Hall, Steven C.; Addona, Terri; Allen, Simon; Dodder, Nathan G.; Ghosh, Mousumi; Held, Jason M.; Hedrick, Victoria; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S.; Riley, C. Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A.; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H.; Buck, Charles; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel; MacCoss, Michael; Neubert, Thomas A.; Paulovich, Amanda; Regnier, Fred; Skates, Steven J.; Tempst, Paul; Wang, Mu; Carr, Steven A.

    2013-01-01

    Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities. PMID:23689285

  15. Comparing Phytophthora ramorum diagnostic protocols for the national Sudden Oak death stream monitoring program

    Treesearch

    W. Sutton; E.M. Hansen; P. Reeser; A. Kanaskie

    2008-01-01

    Oregon was a participant in the pilot test of the national stream monitoring protocol for SOD. We routinely and continuously monitor about 50 streams in and near the SOD quarantine area in southwest Oregon using foliage baits. For the national protocol, we added six additional streams beyond the area of known infestation, and compared results from different diagnostic...

  16. Beam quality corrections for parallel-plate ion chambers in electron reference dosimetry

    NASA Astrophysics Data System (ADS)

    Zink, K.; Wulff, J.

    2012-04-01

    Current dosimetry protocols (AAPM, IAEA, IPEM, DIN) recommend parallel-plate ionization chambers for dose measurements in clinical electron beams. This study presents detailed Monte Carlo simulations of beam quality correction factors for four different types of parallel-plate chambers: NACP-02, Markus, Advanced Markus and Roos. These chambers differ in constructive details which should have notable impact on the resulting perturbation corrections, hence on the beam quality corrections. The results reveal deviations to the recommended beam quality corrections given in the IAEA TRS-398 protocol in the range of 0%-2% depending on energy and chamber type. For well-guarded chambers, these deviations could be traced back to a non-unity and energy-dependent wall perturbation correction. In the case of the guardless Markus chamber, a nearly energy-independent beam quality correction is resulting as the effects of wall and cavity perturbation compensate each other. For this chamber, the deviations to the recommended values are the largest and may exceed 2%. From calculations of type-B uncertainties including effects due to uncertainties of the underlying cross-sectional data as well as uncertainties due to the chamber material composition and chamber geometry, the overall uncertainty of calculated beam quality correction factors was estimated to be <0.7%. Due to different chamber positioning recommendations given in the national and international dosimetry protocols, an additional uncertainty in the range of 0.2%-0.6% is present. According to the IAEA TRS-398 protocol, the uncertainty in clinical electron dosimetry using parallel-plate ion chambers is 1.7%. This study may help to reduce this uncertainty significantly.

  17. Results of the Australasian (Trans-Tasman Oncology Group) radiotherapy benchmarking exercise in preparation for participation in the PORTEC-3 trial.

    PubMed

    Jameson, Michael G; McNamara, Jo; Bailey, Michael; Metcalfe, Peter E; Holloway, Lois C; Foo, Kerwyn; Do, Viet; Mileshkin, Linda; Creutzberg, Carien L; Khaw, Pearly

    2016-08-01

    Protocol deviations in Randomised Controlled Trials have been found to result in a significant decrease in survival and local control. In some cases, the magnitude of the detrimental effect can be larger than the anticipated benefits of the interventions involved. The implementation of appropriate quality assurance of radiotherapy measures for clinical trials has been found to result in fewer deviations from protocol. This paper reports on a benchmarking study conducted in preparation for the PORTEC-3 trial in Australasia. A benchmarking CT dataset was sent to each of the Australasian investigators, it was requested they contour and plan the case according to trial protocol using local treatment planning systems. These data was then sent back to Trans-Tasman Oncology Group for collation and analysis. Thirty three investigators from eighteen institutions across Australia and New Zealand took part in the study. The mean clinical target volume (CTV) volume was 383.4 (228.5-497.8) cm(3) and the mean dose to a reference gold standard CTV was 48.8 (46.4-50.3) Gy. Although there were some large differences in the contouring of the CTV and its constituent parts, these did not translate into large variations in dosimetry. Where individual investigators had deviations from the trial contouring protocol, feedback was provided. The results of this study will be used to compare with the international study QA for the PORTEC-3 trial. © 2016 The Royal Australian and New Zealand College of Radiologists.

  18. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  19. Citizen Science and Community Engagement in Tick Surveillance-A Canadian Case Study.

    PubMed

    Lewis, Julie; Boudreau, Corinne R; Patterson, James W; Bradet-Legris, Jonathan; Lloyd, Vett K

    2018-03-02

    Lyme disease is the most common tick-borne disease in North America and Europe, and on-going surveillance is required to monitor the spread of the tick vectors as their populations expand under the influence of climate change. Active surveillance involves teams of researchers collecting ticks from field locations with the potential to be sites of establishing tick populations. This process is labor- and time-intensive, limiting the number of sites monitored and the frequency of monitoring. Citizen science initiatives are ideally suited to address this logistical problem and generate high-density and complex data from sites of community importance. In 2014, the same region was monitored by academic researchers, public health workers, and citizen scientists, allowing a comparison of the strengths and weaknesses of each type of surveillance effort. Four community members persisted with tick collections over several years, collectively recovering several hundred ticks. Although deviations from standard surveillance protocols and the choice of tick surveillance sites makes the incorporation of community-generated data into conventional surveillance analyses more complex, this citizen science data remains useful in providing high-density longitudinal tick surveillance of a small area in which detailed ecological observations can be made. Most importantly, partnership between community members and researchers has proven a powerful tool in educating communities about of the risk of tick-vectored diseases and in encouraging tick bite prevention.

  20. Forest Soil Disturbance Monitoring Protocol: Volume I: Rapid assessment

    Treesearch

    Deborah S. Page-Dumroese; Ann M. Abbott; Thomas M. Rice

    2009-01-01

    This volume of the Forest Soil Disturbance Monitoring Protocol (FSDMP) describes how to monitor forest sites before and after ground disturbing management activities for physical attributes that could influence site resilience and long-term sustainability. The attributes describe surface conditions that affect site sustainability and hydrologic function. Monitoring the...

  1. Effect of Examiner Experience and Technique on the Alternate Cover Test

    PubMed Central

    Anderson, Heather A.; Manny, Ruth E.; Cotter, Susan A.; Mitchell, G. Lynn; Irani, Jasmine A.

    2013-01-01

    Purpose To compare the repeatability of the alternate cover test between experienced and inexperienced examiners and the effects of dissociation time and examiner bias. Methods Two sites each had an experienced examiner train 10 subjects (inexperienced examiners) to perform short and long dissociation time alternate cover test protocols at near. Each site conducted testing sessions with an examiner triad (experienced examiner and two inexperienced examiners) who were masked to each other’s results. Each triad performed the alternate cover test on 24 patients using both dissociation protocols. In an attempt to introduce bias, each of the paired inexperienced examiners was given a different graph of phoria distribution for the general population. Analysis techniques that adjust for correlations introduced when multiple measurements are obtained on the same patient were used to investigate the effect of examiner and dissociation time on each outcome. Results The range of measured deviations spanned 27.5 prism diopters (Δ) base-in to 17.5Δ base-out. The absolute mean difference between experienced and inexperienced examiners was 2.28 ± 2.4Δ and at least 60% of differences were ≤2Δ. Larger deviations were measured with the long dissociation protocol for both experienced and inexperienced examiners (mean difference range = 1.17 to 2.14Δ, p < 0.0001). The percentage of measured small deviations (2Δ base-out to 2Δ base-in) did not differ between inexperienced examiners biased with the narrow vs. wide theoretical distributions (p = 0.41). The magnitude and direction of the deviation had no effect on the size of the differences obtained with different examiners or dissociation times. Conclusions Although inexperienced examiners differed significantly from experienced examiners, most differences were <2Δ suggesting good reliability of inexperienced examiners’ measurements. Examiner bias did not have a substantial effect on inexperienced examiner measurements; however, increased dissociation resulted in larger measured deviations for all examiners. PMID:20125058

  2. National protocol framework for the inventory and monitoring of bees

    USGS Publications Warehouse

    Droege, Sam; Engler, Joseph D.; Sellers, Elizabeth A.; Lee O'Brien,

    2016-01-01

    This national protocol framework is a standardized tool for the inventory and monitoring of the approximately 4,200 species of native and non-native bee species that may be found within the National Wildlife Refuge System (NWRS) administered by the U.S. Fish and Wildlife Service (USFWS). However, this protocol framework may also be used by other organizations and individuals to monitor bees in any given habitat or location. Our goal is to provide USFWS stations within the NWRS (NWRS stations are land units managed by the USFWS such as national wildlife refuges, national fish hatcheries, wetland management districts, conservation areas, leased lands, etc.) with techniques for developing an initial baseline inventory of what bee species are present on their lands and to provide an inexpensive, simple technique for monitoring bees continuously and for monitoring and evaluating long-term population trends and management impacts. The latter long-term monitoring technique requires a minimal time burden for the individual station, yet can provide a good statistical sample of changing populations that can be investigated at the station, regional, and national levels within the USFWS’ jurisdiction, and compared to other sites within the United States and Canada. This protocol framework was developed in cooperation with the United States Geological Survey (USGS), the USFWS, and a worldwide network of bee researchers who have investigated the techniques and methods for capturing bees and tracking population changes. The protocol framework evolved from field and lab-based investigations at the USGS Bee Inventory and Monitoring Laboratory at the Patuxent Wildlife Research Center in Beltsville, Maryland starting in 2002 and was refined by a large number of USFWS, academic, and state groups. It includes a Protocol Introduction and a set of 8 Standard Operating Procedures or SOPs and adheres to national standards of protocol content and organization. The Protocol Narrative describes the history and need for the protocol framework and summarizes the basic elements of objectives, sampling design, field methods, training, data management, analysis, and reporting. The SOPs provide more detail and specific instructions for implementing the protocol framework. A central database, for managing all the resulting data is under development. We welcome use of this protocol framework by our partners, as appropriate for their bee inventory and monitoring objectives.

  3. Maternal-Fetal Monitoring of Opioid-Exposed Pregnancies: Analysis of a Pilot Community-Based Protocol and Review of the Literature.

    PubMed

    Ryan, Gareth; Dooley, Joe; Windrim, Rory; Bollinger, Megan; Gerber Finn, Lianne; Kelly, Len

    2017-06-01

    To describe/analyse a novel, community-based prenatal monitoring protocol for opioid-exposed pregnancies developed by our centre in 2014 to optimize prenatal care for this population. A literature review of published monitoring protocols for this population is also presented. Retrospective comparison of pre-protocol (n = 215) and post-protocol (n = 251) cohorts. Medline and Embase were searched between 2000-2016 using MeSH terms: [fetal monitoring OR prenatal care] AND [opioid-related disorders OR substance-related disorders] in Medline and [fetal monitoring OR prenatal care] AND [opiate addiction OR substance abuse] in Embase, producing 518 results. Thirteen studies included protocols for monitoring opioid-exposed pregnancies. No comprehensive monitoring protocols with high-quality supporting evidence were found. We evaluated 466 opioid-exposed pregnancies, 215 before and 251 after introduction of the protocol. Since implementation, there was a significant increase in the number of opioid-exposed patients who have underwent urine drug screening (72.6% to 89.2%, P < 0.0001); a significant reduction in the number of urine drug screenings positive for illicit opioids (50.2% to 29.1%, P < 0.0001); and a significant increase in the number of patients who discontinued illicit opioid use by the time of delivery (24.7% to 39.4%, P < 0.01). There was no difference in the CS rate (27.4% vs. 26.3%, P > 0.05). There were no observed differences in the rate of preterm birth, birth weight <2500 g, or Apgar score <7 (P > 0.05). Care of women with increased opioid use during pregnancy is an important but under-studied health issue. A novel protocol for focused antenatal care provision for women with opioid-exposed pregnancies improves standard of care and maternal/fetal outcomes. Copyright © 2017. Published by Elsevier Inc.

  4. Telephone-assisted placement of air nicotine monitors to validate self-reported smoke-free home policies

    PubMed Central

    Berg, C.J.; Bundy, L.; Escoffery, C.; Haardörfer, R.; Kegler, M.C.

    2013-01-01

    SUMMARY Objectives To examine the feasibility of telephone-assisted placement of air nicotine monitors among low socio-economic intervention participants, and examine the use of this strategy in differentiating air nicotine concentrations in rooms where smoking is allowed from rooms where smoking is not allowed. Methods Forty participants were recruited from a county health department clinic and were enrolled in a brief smoke-free home policy intervention study. Twenty participants were selected at random for air nicotine monitor placement, and were instructed to telephone study staff who assisted them in monitor placement in their homes at the end of the intervention. Assessments were conducted at Weeks 0 and 8, with air nicotine assessment performed post-test. Results Of the 20 participants, 17 placed and returned the air nicotine monitors, and 16 also completed the follow-up survey. Follow-up survey data were not obtained on one monitor, and one participant who did not return the monitor completed the follow-up survey. Among those who reported a smoke-free policy (n=7), the average nicotine concentration was 0.62 μg/m3 [standard deviation (SD) 0.48]. Among those without a smoke-free policy (n=9), the average nicotine concentration was 2.30 μg/m3 (SD 2.04). Thus, the air nicotine concentration was significantly higher in those rooms where smoking was allowed [t(9, 11)=-2.39, P=0.04]. Conclusions The use of a telephone-assisted protocol for placement of air nicotine monitors was feasible. Despite the variability of air nicotine concentrations in rooms where smoking is allowed compared with rooms where smoking is not allowed, average concentrations were lower in smoke-free rooms. PMID:23480954

  5. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant

    PubMed Central

    Moreno-Garcia, Isabel M.; Palacios-Garcia, Emilio J.; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J.; Varo-Martinez, Marta; Real-Calvo, Rafael J.

    2016-01-01

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant’s components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid. PMID:27240365

  6. Radiotherapy for Prostate Cancer: is it 'what you do' or 'the way that you do it'? A UK Perspective on Technique and Quality Assurance.

    PubMed

    Mason, M D; Moore, R; Jones, G; Lewis, G; Donovan, J L; Neal, D E; Hamdy, F C; Lane, J A; Staffurth, J N

    2016-09-01

    The treatment of prostate cancer has evolved markedly over the last 40 years, including radiotherapy, notably with escalated dose and targeting. However, the optimal treatment for localised disease has not been established in comparative randomised trials. The aim of this article is to describe the history of prostate radiotherapy trials, including their quality assurance processes, and to compare these with the ProtecT trial. The UK ProtecT randomised trial compares external beam conformal radiotherapy, surgery and active monitoring for clinically localised prostate cancer and will report on the primary outcome (disease-specific mortality) in 2016 following recruitment between 1999 and 2009. The embedded quality assurance programme consists of on-site machine dosimetry at the nine trial centres, a retrospective review of outlining and adherence to dose constraints based on the trial protocol in 54 participants (randomly selected, around 10% of the total randomised to radiotherapy, n = 545). These quality assurance processes and results were compared with prostate radiotherapy trials of a comparable era. There has been an increasingly sophisticated quality assurance programme in UK prostate radiotherapy trials over the last 15 years, reflecting dose escalation and treatment complexity. In ProtecT, machine dosimetry results were comparable between trial centres and with the UK RT01 trial. The outlining review showed that most deviations were clinically acceptable, although three (1.4%) may have been of clinical significance and were related to outlining of the prostate. Seminal vesicle outlining varied, possibly due to several prostate trials running concurrently with different protocols. Adherence to dose constraints in ProtecT was considered acceptable, with 80% of randomised participants having two or less deviations and planning target volume coverage was excellent. The ProtecT trial quality assurance results were satisfactory and comparable with trials of its era. Future trials should aim to standardise treatment protocols and quality assurance programmes where possible to reduce complexities for centres involved in multiple trials. Copyright © 2016. Published by Elsevier Ltd.

  7. Changes in deviation of absorbed dose to water among users by chamber calibration shift.

    PubMed

    Katayose, Tetsurou; Saitoh, Hidetoshi; Igari, Mitsunobu; Chang, Weishan; Hashimoto, Shimpei; Morioka, Mie

    2017-07-01

    The JSMP01 dosimetry protocol had adopted the provisional 60 Co calibration coefficient [Formula: see text], namely, the product of exposure calibration coefficient N C and conversion coefficient k D,X . After that, the absorbed dose to water D w  standard was established, and the JSMP12 protocol adopted the [Formula: see text] calibration. In this study, the influence of the calibration shift on the measurement of D w among users was analyzed. The intercomparison of the D w using an ionization chamber was annually performed by visiting related hospitals. Intercomparison results before and after the calibration shift were analyzed, the deviation of D w among users was re-evaluated, and the cause of deviation was estimated. As a result, the stability of LINAC, calibration of the thermometer and barometer, and collection method of ion recombination were confirmed. The statistical significance of standard deviation of D w was not observed, but that of difference of D w among users was observed between N C and [Formula: see text] calibration. Uncertainty due to chamber-to-chamber variation was reduced by the calibration shift, consequently reducing the uncertainty among users regarding D w . The result also pointed out uncertainty might be reduced by accurate and detailed instructions on the setup of an ionization chamber.

  8. Development of protocols to inventory or monitor wildlife, fish, or rare plants

    Treesearch

    David Vesely; Brenda C. McComb; Christina D. Vojta; Lowell H. Suring; Jurai Halaj; Richard S. Holthausen; Benjamin Zuckerberg; Patricia M. Manley

    2006-01-01

    The purpose of this technical guide (hereafter referred to as the Species Protocol Technical Guide) is to provide guidelines for developing inventory and monitoring (I&M) protocols for wildlife, fish, and rare plants (WFRP) using the U.S. Department of Agriculture (USDA) Forest Service technical guide format.

  9. An efficacious oral health care protocol for immunocompromised patients.

    PubMed

    Solomon, C S; Shaikh, A B; Arendorf, T M

    1995-01-01

    A twice-weekly oral and perioral examination was provided to 120 patients receiving antineoplastic therapy. Sixty patients were monitored while following the traditional hospital oral care protocol (chlorhexidine, hydrogen peroxide, sodium bicarbonate, thymol glycol, benzocaine mouthrinse, and nystatin). The mouth care protocol was then changed (experimental protocol = chlorhexidine, benzocaine lozenges, amphotericin B lozenges), and patients were monitored until the sample size matched that of the hospital mouth care regime. There was a statistically significant reduction in oral complications upon introduction and maintenance of the experimental protocol.

  10. SU-E-T-148: Benchmarks and Pre-Treatment Reviews: A Study of Quality Assurance Effectiveness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowenstein, J; Nguyen, H; Roll, J

    Purpose: To determine the impact benchmarks and pre-treatment reviews have on improving the quality of submitted clinical trial data. Methods: Benchmarks are used to evaluate a site’s ability to develop a treatment that meets a specific protocol’s treatment guidelines prior to placing their first patient on the protocol. A pre-treatment review is an actual patient placed on the protocol in which the dosimetry and contour volumes are evaluated to be per protocol guidelines prior to allowing the beginning of the treatment. A key component of these QA mechanisms is that sites are provided timely feedback to educate them on howmore » to plan per the protocol and prevent protocol deviations on patients accrued to a protocol. For both benchmarks and pre-treatment reviews a dose volume analysis (DVA) was performed using MIM softwareTM. For pre-treatment reviews a volume contour evaluation was also performed. Results: IROC Houston performed a QA effectiveness analysis of a protocol which required both benchmarks and pre-treatment reviews. In 70 percent of the patient cases submitted, the benchmark played an effective role in assuring that the pre-treatment review of the cases met protocol requirements. The 35 percent of sites failing the benchmark subsequently modified there planning technique to pass the benchmark before being allowed to submit a patient for pre-treatment review. However, in 30 percent of the submitted cases the pre-treatment review failed where the majority (71 percent) failed the DVA. 20 percent of sites submitting patients failed to correct their dose volume discrepancies indicated by the benchmark case. Conclusion: Benchmark cases and pre-treatment reviews can be an effective QA tool to educate sites on protocol guidelines and to minimize deviations. Without the benchmark cases it is possible that 65 percent of the cases undergoing a pre-treatment review would have failed to meet the protocols requirements.Support: U24-CA-180803.« less

  11. Incidence and rates of visual field progression after longitudinally measured optic disc change in glaucoma.

    PubMed

    Chauhan, Balwantray C; Nicolela, Marcelo T; Artes, Paul H

    2009-11-01

    To determine whether glaucoma patients with progressive optic disc change have subsequent visual field progression earlier and at a faster rate compared with those without disc change. Prospective, longitudinal, cohort study. Eighty-one patients with open-angle glaucoma. Patients underwent confocal scanning laser tomography and standard automated perimetry every 6 months. The complete follow-up was divided into initial and subsequent periods. Two initial periods-first 3 years (Protocol A) and first half of the total follow-up (Protocol B)-were used, with the respective remainder being the subsequent follow-up. Disc change during the initial follow-up was determined with liberal, moderate, or conservative criteria of the Topographic Change Analysis. Subsequent field progression was determined with significant pattern deviation change in >or=3 locations (criterion used in the Early Manifest Glaucoma Trial). As a control analysis, field change during the initial follow-up was determined with significant pattern deviation change in >or=1, >or=2, or >or=3 locations. Survival time to subsequent field progression, rates of mean deviation (MD) change, and positive and negative likelihood ratios. The median (interquartile range) total follow-up was 11.0 (8.0-12.0) years with 22 (18-24) examinations. More patients had disc changes during the initial follow-up compared with field changes. The mean time to field progression was consistently shorter (protocol A, 0.8-1.7 years; protocol B, 0.3-0.7 years) in patients with prior disc change. In the control analysis, patients with prior field change had statistically earlier subsequent field progression (protocol A, 2.9-3.0 years; protocol B, 0.7-0.9). Similarly, patients with either prior disc or field change always had worse mean rates of subsequent MD change, although the distributions overlapped widely. Patients with subsequent field progression were up to 3 times more likely to have prior disc change compared with those without, and up to 5 times more likely to have prior field change compared with those without. Longitudinally measured optic disc change is predictive of subsequent visual field progression and may be an efficacious end point for functional outcomes in clinical studies and trials in glaucoma.

  12. Long-term seafloor monitoring at an open ocean aquaculture site in the western Gulf of Maine, USA: development of an adaptive protocol.

    PubMed

    Grizzle, R E; Ward, L G; Fredriksson, D W; Irish, J D; Langan, R; Heinig, C S; Greene, J K; Abeels, H A; Peter, C R; Eberhardt, A L

    2014-11-15

    The seafloor at an open ocean finfish aquaculture facility in the western Gulf of Maine, USA was monitored from 1999 to 2008 by sampling sites inside a predicted impact area modeled by oceanographic conditions and fecal and food settling characteristics, and nearby reference sites. Univariate and multivariate analyses of benthic community measures from box core samples indicated minimal or no significant differences between impact and reference areas. These findings resulted in development of an adaptive monitoring protocol involving initial low-cost methods that required more intensive and costly efforts only when negative impacts were initially indicated. The continued growth of marine aquaculture is dependent on further development of farming methods that minimize negative environmental impacts, as well as effective monitoring protocols. Adaptive monitoring protocols, such as the one described herein, coupled with mathematical modeling approaches, have the potential to provide effective protection of the environment while minimize monitoring effort and costs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    PubMed

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Video registration of trauma team performance in the emergency department: the results of a 2-year analysis in a Level 1 trauma center.

    PubMed

    Lubbert, Pieter H W; Kaasschieter, Edgar G; Hoorntje, Lidewij E; Leenen, Loek P H

    2009-12-01

    Trauma teams responsible for the first response to patients with multiple injuries upon arrival in a hospital consist of medical specialists or resident physicians. We hypothesized that 24-hour video registration in the trauma room would allow for precise evaluation of team functioning and deviations from Advanced Trauma Life Support (ATLS) protocols. We analyzed all video registrations of trauma patients who visited the emergency room of a Level I trauma center in the Netherlands between September 1, 2000, and September 1, 2002. Analysis was performed with a score list based on ATLS protocols. From a total of 1,256 trauma room presentations, we found a total of 387 video registrations suitable for analysis. The majority of patients had an injury severity score lower than 17 (264 patients), whereas 123 patients were classified as multiple injuries (injury severity score >or=17). Errors in team organization (omission of prehospital report, no evident leadership, unorganized resuscitation, not working according to protocol, and no continued supervision of the patient) lead to significantly more deviations in the treatment than when team organization was uncomplicated. Video registration of diagnostic and therapeutic procedures by a multidisciplinary trauma team facilitates an accurate analysis of possible deviations from protocol. In addition to identifying technical errors, the role of the team leader can clearly be analyzed and related to team actions. Registration strongly depends on availability of video tapes, timely started registration, and hardware functioning. The results from this study were used to develop a training program for trauma teams in our hospital that specifically focuses on the team leader's functioning.

  15. Standardized quality-assessment system to evaluate pressure ulcer care in the nursing home.

    PubMed

    Bates-Jensen, Barbara M; Cadogan, Mary; Jorge, Jennifer; Schnelle, John F

    2003-09-01

    To demonstrate reliability and feasibility of a standardized protocol to assess and score quality indicators relevant to pressure ulcer (PU) care processes in nursing homes (NHs). Descriptive. Eight NHs. One hundred ninety-one NH residents for whom the PU Resident Assessment Protocol of the Minimum Data Set was initiated. Nine quality indicators (two related to screening and prevention of PU, two focused on assessment, and five addressing management) were scored using medical record data, direct human observation, and wireless thigh monitor observation data. Feasibility and reliability of medical record, observation, and thigh monitor protocols were determined. The percentage of participants who passed each of the indicators, indicating care consistent with practice guidelines, ranged from 0% to 98% across all indicators. In general, participants in NHs passed fewer indicators and had more problems with medical record accuracy before a PU was detected (screening/prevention indicators) than they did once an ulcer was documented (assessment and management indicators). Reliability of the medical record protocol showed kappa statistics ranging from 0.689 to 1.00 and percentage agreement from 80% to 100%. Direct observation protocols yielded kappa statistics of 0.979 and 0.928. Thigh monitor protocols showed kappa statistics ranging from 0.609 to 0.842. Training was variable, with the observation protocol requiring 1 to 2 hours, medical records requiring joint review of 20 charts with average time to complete the review of 20 minutes, and the thigh monitor data requiring 1 week for training in data preparation and interpretation. The standardized quality assessment system generated scores for nine PU quality indicators with good reliability and provided explicit scoring rules that permit reproducible conclusions about PU care. The focus of the indicators on care processes that are under the control of NH staff made the protocol useful for external survey and internal quality improvement purposes, and the thigh monitor observational technology provided a method for monitoring repositioning care processes that were otherwise difficult to monitor and manage.

  16. Multimedia telehomecare system using standard TV set.

    PubMed

    Guillén, S; Arredondo, M T; Traver, V; García, J M; Fernández, C

    2002-12-01

    Nowadays, there are a very large number of patients that need specific health support at home. The deployment of broadband communication networks is making feasible the provision of home care services with a proper quality of service. This paper presents a telehomecare multimedia platform that runs over integrated services digital network and internet protocol using videoconferencing standards H.320 and H.323, and standard TV set for patient interaction. This platform allows online remote monitoring: ECG, heart sound, blood pressure. Usability, affordability, and interoperability were considered for the design and development of its hardware and software components. A first evaluation of technical and usability aspects were carried forward with 52 patients of a private clinic and 10 students in the University. Results show a high rate (mean = 4.33, standard deviation--SD = 1.63 in a five-points Likert scale) in the global perception of users on the quality of images, voice, and feeling of virtual presence.

  17. Status and trends monitoring of riparian and aquatic habitat in the Olympic Experimental State Forest: Monitoring protocols

    Treesearch

    Teodora Minkova; Alex D. Foster

    2017-01-01

    Presented here are the monitoring protocols for the Status and Trends Monitoring of Riparian and Aquatic Habitats project in the Olympic Experimental State Forest (OESF). The procedures yield the empirical data needed to address key uncertainties regarding the integration of timber production and habitat conservation across landscapes and assess progress toward...

  18. A Method of Managing Severe Traumatic Brain Injury in the Absence of Intracranial Pressure Monitoring: The Imaging and Clinical Examination Protocol.

    PubMed

    Chesnut, Randall M; Temkin, Nancy; Dikmen, Sureyya; Rondina, Carlos; Videtta, Walter; Petroni, Gustavo; Lujan, Silvia; Alanis, Victor; Falcao, Antonio; de la Fuenta, Gustavo; Gonzalez, Luis; Jibaja, Manuel; Lavarden, Arturo; Sandi, Freddy; Mérida, Roberto; Romero, Ricardo; Pridgeon, Jim; Barber, Jason; Machamer, Joan; Chaddock, Kelley

    2018-01-01

    The imaging and clinical examination (ICE) algorithm used in the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial is the only prospectively investigated clinical protocol for traumatic brain injury management without intracranial pressure (ICP) monitoring. As the default literature standard, it warrants careful evaluation. We present the ICE protocol in detail and analyze the demographics, outcome, treatment intensity, frequency of intervention usage, and related adverse events in the ICE-protocol cohort. The 167 ICE protocol patients were young (median 29 years) with a median Glasgow Coma Scale motor score of 4 but with anisocoria or abnormal pupillary reactivity in 40%. This protocol produced outcomes not significantly different from those randomized to the monitor-based protocol (favorable 6-month extended Glasgow Outcome Score in 39%; 41% mortality rate). Agents commonly employed to treat suspected intracranial hypertension included low-/moderate-dose hypertonic saline (72%) and mannitol (57%), mild hyperventilation (adjusted partial pressure of carbon dioxide 30-35 mm Hg in 73%), and pressors to maintain cerebral perfusion (62%). High-dose hyperosmotics or barbiturates were uncommonly used. Adverse event incidence was low and comparable to the BEST TRIP monitored group. Although this protocol should produce similar/acceptable results under circumstances comparable to those in the trial, influences such as longer pre-hospital times and non-specialist transport personnel, plus an intensive care unit model of aggressive physician-intensive care by small groups of neurotrauma-focused intensivists, which differs from most high-resource models, support caution in expecting the same results in dissimilar settings. Finally, this protocol's ICP-titration approach to suspected intracranial hypertension (vs. crisis management for monitored ICP) warrants further study.

  19. Methods for Monitoring Fish Communities of Buffalo National River and Ozark National Scenic Riverways in the Ozark Plateaus of Arkansas and Missouri: Version 1.0

    USGS Publications Warehouse

    Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.

    2008-01-01

    Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.

  20. Monitoring fish distributions along electrofishing segments

    USGS Publications Warehouse

    Miranda, Leandro E.

    2014-01-01

    Electrofishing is widely used to monitor fish species composition and relative abundance in streams and lakes. According to standard protocols, multiple segments are selected in a body of water to monitor population relative abundance as the ratio of total catch to total sampling effort. The standard protocol provides an assessment of fish distribution at a macrohabitat scale among segments, but not within segments. An ancillary protocol was developed for assessing fish distribution at a finer scale within electrofishing segments. The ancillary protocol was used to estimate spacing, dispersion, and association of two species along shore segments in two local reservoirs. The added information provided by the ancillary protocol may be useful for assessing fish distribution relative to fish of the same species, to fish of different species, and to environmental or habitat characteristics.

  1. Phase-I monitoring of standard deviations in multistage linear profiles

    NASA Astrophysics Data System (ADS)

    Kalaei, Mahdiyeh; Soleimani, Paria; Niaki, Seyed Taghi Akhavan; Atashgar, Karim

    2018-03-01

    In most modern manufacturing systems, products are often the output of some multistage processes. In these processes, the stages are dependent on each other, where the output quality of each stage depends also on the output quality of the previous stages. This property is called the cascade property. Although there are many studies in multistage process monitoring, there are fewer works on profile monitoring in multistage processes, especially on the variability monitoring of a multistage profile in Phase-I for which no research is found in the literature. In this paper, a new methodology is proposed to monitor the standard deviation involved in a simple linear profile designed in Phase I to monitor multistage processes with the cascade property. To this aim, an autoregressive correlation model between the stages is considered first. Then, the effect of the cascade property on the performances of three types of T 2 control charts in Phase I with shifts in standard deviation is investigated. As we show that this effect is significant, a U statistic is next used to remove the cascade effect, based on which the investigated control charts are modified. Simulation studies reveal good performances of the modified control charts.

  2. Error detection capability of a novel transmission detector: a validation study for online VMAT monitoring.

    PubMed

    Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes

    2017-09-01

    The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from  -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2   =  0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.

  3. Error detection capability of a novel transmission detector: a validation study for online VMAT monitoring

    NASA Astrophysics Data System (ADS)

    Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes

    2017-09-01

    The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from  -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2  =  0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.

  4. Quality indicators for eye bank.

    PubMed

    Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta

    2018-03-01

    The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  5. A network monitor for HTTPS protocol based on proxy

    NASA Astrophysics Data System (ADS)

    Liu, Yangxin; Zhang, Lingcui; Zhou, Shuguang; Li, Fenghua

    2016-10-01

    With the explosive growth of harmful Internet information such as pornography, violence, and hate messages, network monitoring is essential. Traditional network monitors is based mainly on bypass monitoring. However, we can't filter network traffic using bypass monitoring. Meanwhile, only few studies focus on the network monitoring for HTTPS protocol. That is because HTTPS data is in the encrypted traffic, which makes it difficult to monitor. This paper proposes a network monitor for HTTPS protocol based on proxy. We adopt OpenSSL to establish TLS secure tunes between clients and servers. Epoll is used to handle a large number of concurrent client connections. We also adopt Knuth- Morris-Pratt string searching algorithm (or KMP algorithm) to speed up the search process. Besides, we modify request packets to reduce the risk of errors and modify response packets to improve security. Experiments show that our proxy can monitor the content of all tested HTTPS websites efficiently with little loss of network performance.

  6. A mobile system for assessment of physiological response to posture transitions.

    PubMed

    Jovanov, Emil; Milosevic, Mladen; Milenković, Aleksandar

    2013-01-01

    Posture changes initiate a dynamic physiological response that can be used as an indicator of the overall health status. We introduce an inconspicuous mobile wellness monitoring system (imWell) that continuously assesses the dynamic physiological response to posture transitions during activities of daily living. imWell utilizes a Zephyr BioHarness 3 physiological monitor that continually reports heart activity and physical activity via Bluetooth to a personal device (e.g. smartphone). The personal device processes the reported activity data in real-time to recognize posture transitions from the accelerometer data and to characterize dynamic heart response to posture changes. It annotates, logs, and uploads the heart activity data to our mHealth server. In this paper we present algorithms for detection of posture transitions and heart activity characterization during a sit-to-stand transition. The proposed system was tested on seven healthy subjects performing a predefined protocol. The total average and standard deviation for sit-to-stand transition time is 2.7 ± 0.69 s, resulting in the change of heart rate of 27.36 ± 9.30 bpm (from 63.3 ± 9.02 bpm to 90.66 ± 10.09 bpm).

  7. Forest Soil Disturbance Monitoring Protocol: Volume II: Supplementary methods, statistics, and data collection

    Treesearch

    Deborah S. Page-Dumroese; Ann M. Abbott; Thomas M. Rice

    2009-01-01

    Volume I and volume II of the Forest Soil Disturbance Monitoring Protocol (FSDMP) provide information for a wide range of users, including technicians, field crew leaders, private landowners, land managers, forest professionals, and researchers. Volume I: Rapid Assessment includes the basic methods for establishing forest soil monitoring transects and consistently...

  8. A field protocol to monitor cavity-nesting birds

    Treesearch

    J. Dudley; V. Saab

    2003-01-01

    We developed a field protocol to monitor populations of cavity-nesting birds in burned and unburned coniferous forests of western North America. Standardized field methods are described for implementing long-term monitoring strategies and for conducting field research to evaluate the effects of habitat change on cavity-nesting birds. Key references (but not...

  9. Monitoring wilderness stream ecosystems

    Treesearch

    Jeffrey C. Davis; G. Wayne Minshall; Christopher T. Robinson; Peter Landres

    2001-01-01

    A protocol and methods for monitoring the major physical, chemical, and biological components of stream ecosystems are presented. The monitoring protocol is organized into four stages. At stage 1 information is obtained on a basic set of parameters that describe stream ecosystems. Each following stage builds upon stage 1 by increasing the number of parameters and the...

  10. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santoro, J. P.; McNamara, J.; Yorke, E.

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged imagesmore » for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.« less

  11. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.« less

  12. Auditory decision aiding in supervisory control of multiple unmanned aerial vehicles.

    PubMed

    Donmez, Birsen; Cummings, M L; Graham, Hudson D

    2009-10-01

    This article is an investigation of the effectiveness of sonifications, which are continuous auditory alerts mapped to the state of a monitored task, in supporting unmanned aerial vehicle (UAV) supervisory control. UAV supervisory control requires monitoring a UAV across multiple tasks (e.g., course maintenance) via a predominantly visual display, which currently is supported with discrete auditory alerts. Sonification has been shown to enhance monitoring performance in domains such as anesthesiology by allowing an operator to immediately determine an entity's (e.g., patient) current and projected states, and is a promising alternative to discrete alerts in UAV control. However, minimal research compares sonification to discrete alerts, and no research assesses the effectiveness of sonification for monitoring multiple entities (e.g., multiple UAVs). The authors conducted an experiment with 39 military personnel, using a simulated setup. Participants controlled single and multiple UAVs and received sonifications or discrete alerts based on UAV course deviations and late target arrivals. Regardless of the number of UAVs supervised, the course deviation sonification resulted in reactions to course deviations that were 1.9 s faster, a 19% enhancement, compared with discrete alerts. However, course deviation sonifications interfered with the effectiveness of discrete late arrival alerts in general and with operator responses to late arrivals when supervising multiple vehicles. Sonifications can outperform discrete alerts when designed to aid operators to predict future states of monitored tasks. However, sonifications may mask other auditory alerts and interfere with other monitoring tasks that require divided attention. This research has implications for supervisory control display design.

  13. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

    PubMed

    Cristache, Corina Marilena; Gurbanescu, Silviu

    2017-01-01

    of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann-Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Mean (and standard deviation) of 3D error at the entry point was 0.798 mm (±0.52), at the implant apex it was 1.17 mm (±0.63), and mean angular deviation was 2.34 (±0.85). A statistically significant reduced 3D error was observed at entry point p = .037, at implant apex p = .008, and also in angular deviation p = .030 in mandible when comparing to maxilla. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan) with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  14. EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that co...

  15. Temperature and current coefficients of lasing wavelength in tunable diode laser spectroscopy.

    PubMed

    Fukuda, M; Mishima, T; Nakayama, N; Masuda, T

    2010-08-01

    The factors determining temperature and current coefficients of lasing wavelength are investigated and discussed under monitoring CO(2)-gas absorption spectra. The diffusion rate of Joule heating at the active layer to the surrounding region is observed by monitoring the change in the junction voltage, which is a function of temperature and the wavelength (frequency) deviation under sinusoidal current modulation. Based on the experimental results, the time interval of monitoring the wavelength after changing the ambient temperature or injected current (scanning rate) has to be constant at least to eliminate the monitoring error induced by the deviation of lasing wavelength, though the temperature and current coefficients of lasing wavelength differ with the rate.

  16. Terrestrial vegetation monitoring protocol for the Mediterranean Coast Network—Cabrillo National Monument, Channel Islands National Park, and Santa Monica Mountains National Recreation Area: Standard Operating Procedures, Version 1.0

    USGS Publications Warehouse

    Tiszler, John; Rodriguez, Dirk; Lombardo, Keith; Sagar, Tarja; Aguilar, Luis; Lee, Lena; Handley, Timothy; McEachern, A. Kathryn; Harrod Starcevich, Leigh Ann; Witter, Marti; Philippi, Tom; Ostermann-Kelm, Stacey

    2016-01-01

    These Standard Operating Procedures are one part of a two-part protocol for monitoring terrestrial vegetation in the Mediterranean Coast Network. The second part of the protocol is the narrative:Tiszler, J., D. Rodriguez, K. Lombardo, T. Sagar, L. Aguilar, L. Lee, T. Handley, K. McEachern, L. Starcevich, M. Witter, T. Philippi, and S. Ostermann-Kelm. 2016. Terrestrial vegetation monitoring protocol for the Mediterranean Coast Network—Cabrillo National Monument, Channel Islands National Park, and Santa Monica Mountains National Recreation Area: Narrative, version 1.0. Natural Resource Report NPS/MEDN/NRR—2016/1296. National Park Service, Fort Collins, Colorado.National parks in the Mediterranean Inventory and Monitoring Network:Cabrillo National Monument (CABR)Channel Islands National Park (CHIS)Santa Monica Mountains National Recreation Area (SAMO)

  17. [Outbreak of Whooping cough in 2016.Écija, Seville, Spain].

    PubMed

    Porras-Povedano, Miguel; Roldán-Garrido, Ana; Santacruz-Hamer, Virginia

    2017-01-18

    Whooping cough is a global public health problem, is a highly contagious disease, and despite universal vaccination increased incidence is observed. The aim of this study was to describe the investigation of a population outbreak. A descriptive study of a population outbreak of whooping cough between February and June 2016 in Ecija (Seville). Case and outbreak definitions was taken of Whooping Cough Monitoring Protocol. Information was collected from Health History, Epidemiological Monitoring System and Laboratory. For statistical analysis used the free software R, for measuring quantitative variables were presented, median, standard deviation, minimum and maximum values and percentiles for qualitative variables frequency distribution. 91 suspected cases were identified, ruling 33. Of the remaining 58, 42 cases were confirmed and 16 probable cases. The cases have presented an average age of 10,24 years. 62,1% of cases occurred in women. The incidence during the duration of the outbreak was 148,51 cases/100.000 people globally, and 851,06 cases/100.000 people in under 14 years. All children under 18 years were successfully vaccinated in primary vaccination and only 2 children lacked the fifth dose. The average time between onset of symptoms and diagnosis was 24,86 days. The establishment of monitoring and control measures have managed to limit and resolve the outbreak. It is recommended to enhance the information and coordination between the various levels of care (Primary care/Specialist) and professionals (Clinical/Epidemiology).

  18. IoT real time data acquisition using MQTT protocol

    NASA Astrophysics Data System (ADS)

    Atmoko, R. A.; Riantini, R.; Hasin, M. K.

    2017-05-01

    The Internet of Things (IoT) provides ease to monitor and to gain sensor data through the Internet [1]. The need of high quality data is increasing to the extent that data monitoring and acquisition system in real time is required, such as smart city or telediagnostic in medical areas [2]. Therefore, an appropriate communication protocol is required to resolve these problems. Lately, researchers have developed a lot of communication protocols for IoT, of which each has advantages and disadvantages. This study proposes the utilization of MQTT as a communication protocol, which is one of data communication protocols for IoT. This study used temperature and humidity sensors because the physical parameters are often needed as parameters of environment condition [3]. Data acquisition was done in real-time and stored in MySQL database. This study is also completed by interface web-based and mobile for online monitoring. This result of this study is the enhancement of data quality and reliability using MQTT protocol.

  19. Evidence supporting the need for a common soil monitoring protocol

    Treesearch

    Derrick A. Reeves; Mark D. Coleman; Deborah S. Page-Dumroese

    2013-01-01

    Many public land management agencies monitor forest soils for levels of disturbance related to management activities. Although several soil disturbance monitoring protocols based on visual observation have been developed to assess the amount and types of disturbance caused by forest management, no common method is currently used on National Forest lands in the United...

  20. An inventory and monitoring plan for a Sonoran Desert ecosystem; Barry M. Goldwater Range-West

    USGS Publications Warehouse

    Villarreal, Miguel L.; van Riper, Charles; Lovich, Robert E.; Palmer, Robert L.; Nauman, Travis; Studd, Sarah E.; Drake, Sam; Rosenberg, Abigail S.; Malusa, Jim; Pearce, Ronald L.

    2011-01-01

    Marine Corps Air Station Yuma manages the Barry M. Goldwater Range-West, which encompasses approximately 2,800 square kilometers of Sonoran Desert habitat in southwestern Arizona. The Barry M. Goldwater Range is a major U.S. military installation designed as an air combat training location for the U.S. Marine Corps and U.S. Air Force, but it also includes some of the most pristine desert habitat in the United States. In an effort to ensure the long-term viability of this unique natural resource, the U.S. Geological Survey (USGS) has developed an Integrated Natural Resources Management Plan and Inventory and Monitoring Plan to guide natural resource management of the Barry M. Goldwater Range-West. This Inventory and Monitoring Plan provides a framework for long-term ecosystem monitoring on Barry M. Goldwater Range-West lands by identifying existing and potential threats to ecosystem function, prioritizing resources for monitoring, and providing information and protocols necessary to initiate a long-term ecosystem monitoring program. The Inventory and Monitoring Plan and related protocols were developed through extensive review of existing Sonoran Desert monitoring programs and monitoring literature and through a 2-day workshop with resource managers, monitoring experts, and other stakeholders. The Barry M. Goldwater Range-West Inventory and Monitoring Plan stresses the importance of regional monitoring partnerships and protocol standardization for understanding landscape-scale ecosystem changes in the Sonoran Desert; information and protocols contained within the plan may also be of interest to land managers engaged in large-scale ecosystem monitoring and adaptive management of other arid regions.

  1. Checklists and Monitoring in the Cockpit: Why Crucial Defenses Sometimes Fail

    NASA Technical Reports Server (NTRS)

    Dismukes, R. Key; Berman, Ben

    2010-01-01

    Checklists and monitoring are two essential defenses against equipment failures and pilot errors. Problems with checklist use and pilots failures to monitor adequately have a long history in aviation accidents. This study was conducted to explore why checklists and monitoring sometimes fail to catch errors and equipment malfunctions as intended. Flight crew procedures were observed from the cockpit jumpseat during normal airline operations in order to: 1) collect data on monitoring and checklist use in cockpit operations in typical flight conditions; 2) provide a plausible cognitive account of why deviations from formal checklist and monitoring procedures sometimes occur; 3) lay a foundation for identifying ways to reduce vulnerability to inadvertent checklist and monitoring errors; 4) compare checklist and monitoring execution in normal flights with performance issues uncovered in accident investigations; and 5) suggest ways to improve the effectiveness of checklists and monitoring. Cognitive explanations for deviations from prescribed procedures are provided, along with suggestions for countermeasures for vulnerability to error.

  2. Improvement of burn pain management through routine pain monitoring and pain management protocol.

    PubMed

    Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook

    2013-06-01

    Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  3. A protocol using coho salmon to monitor Tongass National Forest Land and Resource Management Plan standards and guidelines for fish habitat.

    Treesearch

    M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl

    2008-01-01

    We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...

  4. Supervised versus unsupervised technology-based levodopa monitoring in Parkinson's disease: an intrasubject comparison.

    PubMed

    Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2018-06-01

    We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.

  5. 2018 EPA Protocol Gas Verification Program Participants

    EPA Pesticide Factsheets

    A list of participants for 2016 EPA's Protocol Gas Verification Program (PGVP) for stationary source monitoring. The list also has vendor IDs, which are production site-specific, and are the same ones used in the PGVP for ambient air monitoring.

  6. Current Status of EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas reference standards are needed to calibrate and audit continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensur...

  7. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  8. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  9. ECOC comparison exercise with identical thermal protocols after temperature offset correction - instrument diagnostics by in-depth evaluation of operational parameters

    NASA Astrophysics Data System (ADS)

    Panteliadis, P.; Hafkenscheid, T.; Cary, B.; Diapouli, E.; Fischer, A.; Favez, O.; Quincey, P.; Viana, M.; Hitzenberger, R.; Vecchi, R.; Saraga, D.; Sciare, J.; Jaffrezo, J. L.; John, A.; Schwarz, J.; Giannoni, M.; Novak, J.; Karanasiou, A.; Fermo, P.; Maenhaut, W.

    2015-02-01

    A comparison exercise on thermal-optical elemental carbon/organic carbon (ECOC) analysers was carried out among 17 European laboratories. Contrary to previous comparison exercises, the 17 participants made use of an identical instrument set-up, after correcting for temperature offsets with the application of a recently developed temperature calibration kit (Sunset Laboratory Inc, OR, US). Temperature offsets reported by participants ranged from -93 to +100 °C per temperature step. Five filter samples and two sucrose solutions were analysed with both the EUSAAR2 and NIOSH870 thermal protocols. z scores were calculated for total carbon (TC); nine outliers and three stragglers were identified. Three outliers and eight stragglers were found for EC. Overall, the participants provided results between the warning levels with the exception of two laboratories that showed poor performance, the causes of which were identified and corrected through the course of the comparison exercise. The TC repeatability and reproducibility (expressed as relative standard deviations) were 11 and 15% for EUSAAR2 and 9.2 and 12% for NIOSH870; the standard deviations for EC were 15 and 20% for EUSAAR2 and 20 and 26% for NIOSH870. TC was in good agreement between the two protocols, TCNIOSH870 = 0.98 × TCEUSAAR2 (R2 = 1.00, robust means). Transmittance (TOT) calculated EC for NIOSH870 was found to be 20% lower than for EUSAAR2, ECNIOSH870 = 0.80 × ECEUSAAR2 (R2 = 0.96, robust means). The thermograms and laser signal values were compared and similar peak patterns were observed per sample and protocol for most participants. Notable deviations from the typical patterns indicated either the absence or inaccurate application of the temperature calibration procedure and/or pre-oxidation during the inert phase of the analysis. Low or zero pyrolytic organic carbon (POC), as reported by a few participants, is suggested as an indicator of an instrument-specific pre-oxidation. A sample-specific pre-oxidation effect was observed for filter G, for all participants and both thermal protocols, indicating the presence of oxygen donors on the suspended particulate matter. POC (TOT) levels were lower for NIOSH870 than for EUSAAR2, which is related to the heating profile differences of the two thermal protocols.

  10. SU-E-T-620: Dosimetric Compliance Study for a New Prostate Protocol of Combined High Dose Rate Brachytherapy and Stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, C; Giaddui, T; Den, R

    2014-06-15

    Purpose: To investigate the adherence of treatment plans of prostate cancer patients with the dosimetric compliance criteria of the new in house phase I trial of high dose rate (HDR) brachytherapy combined with stereotactic body radiotherapy (SBRT) for intermediate risk prostate cancer patients. Methods: Ten prostate cancer patients were treated using this trial. They received one fraction of HDR to 15Gy, followed by external beam(EB) boost of 3.2Gy(Level 1, five patients) or 3.94Gy(level 2, five patients) per fraction for 10 or 7 fractions, respectively, both equivalent to EB treatments of 113.5Gy in 2Gy fractions. The EB plans were either IMRTmore » or VMAT plans. DVH analysis was performed to verify the adherence of treatment plans to the dosimetric criteria of the trial. Results: For Level 1 patients, target coverage were adequate, with CTV V32Gy(%) of 99.0±1.0 (mean ± 1 standard deviation), and PTV V31Gy(%) of 99.6±0.3. PTV V32.9Gy(%) is 1.4±3.1 and PTVmax is 32.9±0.2Gy. Rectum, bladder and femoral heads sparing were well within protocol criteria. For Level 2 patients, CTV V27.6Gy(%) is 98.7±1.8; PTV V26.7Gy(%) is 99.0±1.4. PTV V28.4Gy(%) is 1.3±1.4, with three patients having minor deviation from protocol. Again critical structures were spared compliant to the protocol. The analysis of HDR plans show similar results, with adequate dose coverage to the prostate and sparing of critical structures including urethra and rectum. V100(%) and V90(%) of prostate are 96.0±1.1 and 98.9±0.5. Urethra D10(%) is 113.1±2.9. Rectum V80(cc) is 1.4±0.5. Hotspot in prostate is substantially higher than what the protocol specifies. But the criteria for hotspot are only guidelines, serving to lower the dose to urethra . Conclusion: This new high biological equivalent dose prostate trial has been carried out successfully for ten patients. Based on dosimetric analysis, all HDR and external plans were compliant to the protocol criteria, with only minor deviations.« less

  11. Evaluating the Process of Generating a Clinical Trial Protocol

    PubMed Central

    Franciosi, Lui G.; Butterfield, Noam N.; MacLeod, Bernard A.

    2002-01-01

    The research protocol is the principal document in the conduct of a clinical trial. Its generation requires knowledge about the research problem, the potential experimental confounders, and the relevant Good Clinical Practices for conducting the trial. However, such information is not always available to authors during the writing process. A checklist of over 80 items has been developed to better understand the considerations made by authors in generating a protocol. It is based on the most cited requirements for designing and implementing the randomised controlled trial. Items are categorised according to the trial's research question, experimental design, statistics, ethics, and standard operating procedures. This quality assessment tool evaluates the extent that a generated protocol deviates from the best-planned clinical trial.

  12. Spine deviations and orthodontic treatment of asymmetric malocclusions in children

    PubMed Central

    2012-01-01

    Background The aim of this randomized clinical trial was to assess the effect of early orthodontic treatment for unilateral posterior cross bite in the late deciduous and early mixed dentition using orthopedic parameters. Methods Early orthodontic treatment was performed by initial maxillary expansion and subsequent activator therapy (Münster treatment concept). The patient sample was initially comprised of 80 patients with unilateral posterior cross bite (mean age 7.3 years, SD 2.1 years). After randomization, 77 children attended the initial examination appointment (therapy = 37, control = 40); 31 children in the therapy group and 35 children in the control group were monitored at the follow-up examination (T2). The mean interval between T1 and T2 was 1.1 years (SD 0.2 years). Rasterstereography was used for back shape analysis at T1 and T2. Using the profile, the kyphotic and lordotic angle, the surface rotation, the lateral deviation, pelvic tilt and pelvic torsion, statistical differences at T1 and T2 between the therapy and control groups were calculated (t-test). Our working hypothesis was, that early orthodontic treatment can induce negative therapeutic changes in body posture through thoracic and lumbar position changes in preadolescents with uniltaral cross bite. Results No clinically relevant differences between the control and the therapy groups at T1 and T2 were found for the parameters of kyphotic and lordotic angle, the surface rotation, lateral deviation, pelvic tilt, and pelvic torsion. Conclusions Our working hypothesis was tested to be not correct (within the limitations of this study). This randomized clinical trial demonstrates that in a juvenile population with unilateral posterior cross bite the selected early orthodontic treatment protocol does not affect negatively the postural parameters. Trial registration DRKS00003497 on DRKS PMID:22906114

  13. A review of protocols for monitoring streams and juvenile fish in forested regions of the Pacific Northwest.

    Treesearch

    Scott A. Stolnack; Mason D. Bryant; Robert C. Wissmar

    2005-01-01

    This document reviews existing and proposed protocols used to monitor stream ecosystem conditions and responses to land management activities in the Pacific Northwest. Because of recent work aimed at improving the utility of habitat survey and fish abundance assessment methods, this review focuses on current (since 1993) monitoring efforts that assess stream habitat...

  14. A habitat-based point-count protocol for terrestrial birds, emphasizing Washington and Oregon.

    Treesearch

    Mark H. Huff; Kelly A. Bettinger; Howard L. Ferguson; Martin J. Brown; Bob. Altman

    2000-01-01

    We describe a protocol and provide a summary for point-count monitoring of landbirds that is designed for habitat-based objectives. Presentation is in four steps: preparation and planning, selecting monitoring sites, establishing monitoring stations, and conducting point counts. We describe the basis for doing habitat-based point counts, how they are organized, and how...

  15. CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...

  16. Current Status of EPA Verification Program for EPA Protocol Gases

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  17. EPA Protocol Gas Verification Program - Presented at NIST Gas Panel Meeting

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  18. Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.

    2015-09-29

    This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

  19. Quality assurance in the EORTC 22033-26033/CE5 phase III randomized trial for low grade glioma: the digital individual case review.

    PubMed

    Fairchild, Alysa; Weber, Damien C; Bar-Deroma, Raquel; Gulyban, Akos; Fenton, Paul A; Stupp, Roger; Baumert, Brigitta G

    2012-06-01

    The phase III EORTC 22033-26033/NCIC CE5 intergroup trial compares 50.4 Gy radiotherapy with up-front temozolomide in previously untreated low-grade glioma. We describe the digital EORTC individual case review (ICR) performed to evaluate protocol radiotherapy (RT) compliance. Fifty-eight institutions were asked to submit 1-2 randomly selected cases. Digital ICR datasets were uploaded to the EORTC server and accessed by three central reviewers. Twenty-seven parameters were analysed including volume delineation, treatment planning, organ at risk (OAR) dosimetry and verification. Consensus reviews were collated and summary statistics calculated. Fifty-seven of seventy-two requested datasets from forty-eight institutions were technically usable. 31/57 received a major deviation for at least one section. Relocation accuracy was according to protocol in 45. Just over 30% had acceptable target volumes. OAR contours were missing in an average of 25% of cases. Up to one-third of those present were incorrectly drawn while dosimetry was largely protocol compliant. Beam energy was acceptable in 97% and 48 patients had per protocol beam arrangements. Digital RT plan submission and review within the EORTC 22033-26033 ICR provide a solid foundation for future quality assurance procedures. Strict evaluation resulted in overall grades of minor and major deviation for 37% and 32%, respectively. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    USGS Publications Warehouse

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  1. Detection and quantification system for monitoring instruments

    DOEpatents

    Dzenitis, John M [Danville, CA; Hertzog, Claudia K [Houston, TX; Makarewicz, Anthony J [Livermore, CA; Henderer, Bruce D [Livermore, CA; Riot, Vincent J [Oakland, CA

    2008-08-12

    A method of detecting real events by obtaining a set of recent signal results, calculating measures of the noise or variation based on the set of recent signal results, calculating an expected baseline value based on the set of recent signal results, determining sample deviation, calculating an allowable deviation by multiplying the sample deviation by a threshold factor, setting an alarm threshold from the baseline value plus or minus the allowable deviation, and determining whether the signal results exceed the alarm threshold.

  2. Forest bird monitoring protocol for strategic habitat conservation and endangered species management on O'ahu Forest National Wildlife Refuge, Island of O'ahu, Hawai'i

    USGS Publications Warehouse

    Camp, Richard J.; Gorresen, P. Marcos; Banko, Paul C.

    2011-01-01

    This report describes the results of a pilot forest bird survey and a consequent forest bird monitoring protocol that was developed for the O'ahu Forest National Wildlife Refuge, O'ahu Island, Hawai'i. The pilot survey was conducted to inform aspects of the monitoring protocol and to provide a baseline with which to compare future surveys on the Refuge. The protocol was developed in an adaptive management framework to track bird distribution and abundance and to meet the strategic habitat conservation requirements of the Refuge. Funding for this research was provided through a Science Support Partnership grant sponsored jointly by the U.S. Geological Survey (USGS) and the U.S. Fish and Wildlife Service (USFWS).

  3. Availability of anesthetic effect monitoring: utilization, intraoperative management and time to extubation in liver transplantation.

    PubMed

    Schumann, R; Hudcova, J; Bonney, I; Cepeda, M S

    2010-12-01

    Titration of volatile anesthetics to anesthetic effect monitoring using the bispectral index (BIS) has been shown to decrease anesthetic requirements and facilitate recovery from anesthesia unrelated to liver transplantation (OLT). To determine whether availability of such monitoring influences its utilization pattern and affect anesthetic care and outcomes in OLT, we conducted a retrospective analysis in recipients with and without such monitoring. We evaluated annual BIS utilization over a period of 7 years, and compared 41 BIS-monitored patients to 42 controls. All received an isoflurane/air/oxygen and opioid-based anesthetic with planned postoperative ventilation. Data collection included age, body mass index (BMI), gender, Model for End-stage Liver Disease (MELD) score, and time to extubation (TtE). Mean preanhepatic, anhepatic, and postanhepatic end-tidal isoflurane concentrations were compared, as well as BIS values for each phase of OLT using the Kruskal-Wallis and Wilcoxon signed-rank tests, respectively. The use of anesthetic effect monitoring when available increased steadily from 15% of cases in the first year to almost 93% by year 7. There was no significant difference in age, gender, BMI, MELD, or TtE between groups. The BIS group received less inhalational anesthetic during each phase of OLT compared to the control group. However, this difference was statistically significant only during the anhepatic phase (P = .026), and was clinically not impressive. Within the BIS group, the mean BIS value was 38.74 ± 5.25 (mean ± standard deviation), and there was no difference for the BIS value between different transplant phases. Availability of anesthetic effect monitoring as an optional monitoring tool during OLT results in its increasing utilization by anesthesia care teams over time. However, unless integrated into an intraoperative algorithm and an early extubation protocol for fast tracking of OLT recipients, this utilization does not appear to provide a clinical benefit but instead drives cost. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  5. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDougall, R.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  6. Allocation of substance use disorder patients to appropriate levels of care: feasibility of matching guidelines in routine practice in Dutch treatment centres.

    PubMed

    Merkx, Maarten J M; Schippers, Gerard M; Koeter, Maarten J W; Vuijk, Pieter Jelle; Oudejans, Suzan; de Vries, Carlijn C Q; van den Brink, Wim

    2007-03-01

    To examine the feasibility of implementing evidence-based guidelines for patient-treatment-matching to levels of care in two Dutch substance abuse treatment centres. Multi-centre observational follow-up study. Two large substance abuse treatment centres (SATCs). All 4394 referrals to the two SATCs in 2003. Baseline patient characteristics needed for treatment allocation according to protocol, treatment allocation according to matching protocol, treatment allocation according to actual level of care (LOC) entered. Comparison of recommended and actual LOC entered. Evaluation of reasons for observed differences between recommended and actual LOC entered. Data needed for treatment allocation according to protocol were available for 2269 (51.6%) patients. Data needed for evaluation of actual LOC entered were available for 1765 (40.2%) patients. Of these patients, 1089 (60.8%) were allocated according to protocol: 48.4% based on the guideline algorithm and 12.4% based on clinically justified deviations from this algorithm. The main reason for deviation was a different appraisal of addiction severity, made by the intake counsellor compared to the protocol. The feasibility of guideline-based treatment allocation is seriously limited due to inadequate data collection of patient characteristics and suboptimal guideline-based treatment allocation. As a consequence, only 24.4% of the patients could be evaluated as being matched properly to the treatment planned. The results indicate several barriers which limit the adequate implementation of patient-treatment-matching guidelines: problems in the infrastructure of data collection and storage and the inertia of intake staff who did not adhere to the guidelines for assessment and matching.

  7. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    PubMed

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  8. Application of Allan Deviation to Assessing Uncertainties of Continuous-measurement Instruments, and Optimizing Calibration Schemes

    NASA Astrophysics Data System (ADS)

    Jacobson, Gloria; Rella, Chris; Farinas, Alejandro

    2014-05-01

    Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits of Signal Averaging in Atmospheric Trace-Gas Monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS)," Applied Physics, B57, pp 131-139, April 1993

  9. Mercury Assessment and Monitoring Protocol for the Bear Creek Watershed, Colusa County, California

    USGS Publications Warehouse

    Suchanek, Thomas H.; Hothem, Roger L.; Rytuba, James J.; Yee, Julie L.

    2010-01-01

    This report summarizes the known information on the occurrence and distribution of mercury (Hg) in physical/chemical and biological matrices within the Bear Creek watershed. Based on these data, a matrix-specific monitoring protocol for the evaluation of the effectiveness of activities designed to remediate Hg contamination in the Bear Creek watershed is presented. The monitoring protocol documents procedures for collecting and processing water, sediment, and biota for estimation of total Hg (TotHg) and monomethyl mercury (MMeHg) in the Bear Creek watershed. The concurrent sampling of TotHg and MMeHg in biota as well as water and sediment from 10 monitoring sites is designed to assess the relative bioavailability of Hg released from Hg sources in the watershed and identify environments conducive to Hg methylation. These protocols are designed to assist landowners, land managers, water quality regulators, and scientists in determining whether specific restoration/mitigation actions lead to significant progress toward achieving water quality goals to reduce Hg in Bear and Sulphur Creeks.

  10. High-Throughput, Survivable Protocols for CDMA Packet-Radio Networks (SRNTN-74)

    DTIC Science & Technology

    1990-03-01

    published in a paper by Jubin and Tornow [2], however the reader must be aware that the current SURAP algorithms deviate slightly from this reference...threading policy outlined by Jubin and Tornow is equivalent to a link- level window size of one, meaning a policy of not transmitting a new packet to a... Tornow . The DARPA packet-radio network protocols. Proceedings of the IEEE, 75(1):21-32, January 1987. [31 N. Gower and J. Jubin. Congestion control using

  11. Indicators and protocols for monitoring impacts of formal and informal trails in protected areas

    USGS Publications Warehouse

    Marion, Jeffrey L.; Leung, Yu-Fai

    2011-01-01

    Trails are a common recreation infrastructure in protected areas and their conditions affect the quality of natural resources and visitor experiences. Various trail impact indicators and assessment protocols have been developed in support of monitoring programs, which are often used for management decision-making or as part of visitor capacity management frameworks. This paper reviews common indicators and assessment protocols for three types of trails, surfaced formal trails, unsurfaced formal trails, and informal (visitor-created) trails. Monitoring methods and selected data from three U.S. National Park Service units are presented to illustrate some common trail impact indicators and assessment options.

  12. Couch height–based patient setup for abdominal radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohira, Shingo; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita; Ueda, Yoshihiro

    2016-04-01

    There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on themore » computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.« less

  13. Remote Sensing and the Kyoto Protocol: A Review of Available and Future Technology for Monitoring Treaty Compliance

    NASA Technical Reports Server (NTRS)

    Imhoff, Marc L.; Rosenquist, A.; Milne, A. K.; Dobson, M. C.; Qi, J.

    2000-01-01

    An International workshop was held to address how remote sensing technology could be used to support the environmental monitoring requirements of the Kyoto Protocol. An overview of the issues addressed and the findings of the workshop are discussed.

  14. Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds.

    PubMed

    Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto

    2015-02-01

    Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.

  15. Lightweight UDP Pervasive Protocol in Smart Home Environment Based on Labview

    NASA Astrophysics Data System (ADS)

    Kurniawan, Wijaya; Hannats Hanafi Ichsan, Mochammad; Rizqika Akbar, Sabriansyah; Arwani, Issa

    2017-04-01

    TCP (Transmission Control Protocol) technology in a reliable environment was not a problem, but not in an environment where the entire Smart Home network connected locally. Currently employing pervasive protocols using TCP technology, when data transmission is sent, it would be slower because they have to perform handshaking process in advance and could not broadcast the data. On smart home environment, it does not need large size and complex data transmission between monitoring site and monitoring center required in Smart home strain monitoring system. UDP (User Datagram Protocol) technology is quick and simple on data transmission process. UDP can broadcast messages because the UDP did not require handshaking and with more efficient memory usage. LabVIEW is a programming language software for processing and visualization of data in the field of data acquisition. This paper proposes to examine Pervasive UDP protocol implementations in smart home environment based on LabVIEW. UDP coded in LabVIEW and experiments were performed on a PC and can work properly.

  16. Noninvasive measurement of dynamic correlation functions

    NASA Astrophysics Data System (ADS)

    Uhrich, Philipp; Castrignano, Salvatore; Uys, Hermann; Kastner, Michael

    2017-08-01

    The measurement of dynamic correlation functions of quantum systems is complicated by measurement backaction. To facilitate such measurements we introduce a protocol, based on weak ancilla-system couplings, that is applicable to arbitrary (pseudo)spin systems and arbitrary equilibrium or nonequilibrium initial states. Different choices of the coupling operator give access to the real and imaginary parts of the dynamic correlation function. This protocol reduces disturbances due to the early-time measurements to a minimum, and we quantify the deviation of the measured correlation functions from the theoretical, unitarily evolved ones. Implementations of the protocol in trapped ions and other experimental platforms are discussed. For spin-1 /2 models and single-site observables we prove that measurement backaction can be avoided altogether, allowing for the use of ancilla-free protocols.

  17. Ultra Low Power Signal Oriented Approach for Wireless Health Monitoring

    PubMed Central

    Marinkovic, Stevan; Popovici, Emanuel

    2012-01-01

    In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios. PMID:22969379

  18. Ultra low power signal oriented approach for wireless health monitoring.

    PubMed

    Marinkovic, Stevan; Popovici, Emanuel

    2012-01-01

    In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios.

  19. Improving metabolic monitoring in patients maintained on antipsychotics in Penang, Malaysia.

    PubMed

    Hor, Esther Sl; Subramaniam, Sivasangari; Koay, Jun Min; Bharathy, Arokiamary; Vasudevan, Umadevi; Panickulam, Joseph J; Ng, InnTiong; Arif, Nor Hayati; Russell, Vincent

    2016-02-01

    To evaluate the monitoring of metabolic parameters among outpatients maintained on antipsychotic medications in a general hospital setting in Malaysia and to assess the impact of a local monitoring protocol. By performing a baseline audit of files from a random sample of 300 patients prescribed antipsychotic medications for at least 1 year; we determined the frequency of metabolic monitoring. The findings informed the design of a new local protocol, on which clinical staff was briefed. We re-evaluated metabolic monitoring immediately after implementation, in a small sample of new referrals and current patients. We explored staff perceptions of the initiative with a follow-up focus group, 6 months post-implementation. The baseline audit revealed a sub-optimal frequency of metabolic parameter recording. Re-audit, following implementation of the new protocol, revealed improved monitoring but persisting deficits. Dialogue with the clinical staff led to further protocol modification, clearer definition of staff roles and use of a standard recording template. Focus group findings revealed positive perceptions of the initiative, but persisting implementation barriers, including cultural issues surrounding waist circumference measurement. Responding to challenges in achieving improved routine metabolic monitoring of patients maintained on antipsychotics required on-going dialogue with the clinical staff, in order to address both service pressures and cultural concerns. © The Royal Australian and New Zealand College of Psychiatrists 2015.

  20. A cooled CCD camera-based protocol provides an effective solution for in vitro monitoring of luciferase.

    PubMed

    Afshari, Amirali; Uhde-Stone, Claudia; Lu, Biao

    2015-03-13

    Luciferase assay has become an increasingly important technique to monitor a wide range of biological processes. However, the mainstay protocols require a luminometer to acquire and process the data, therefore limiting its application to specialized research labs. To overcome this limitation, we have developed an alternative protocol that utilizes a commonly available cooled charge-coupled device (CCCD), instead of a luminometer for data acquiring and processing. By measuring activities of different luciferases, we characterized their substrate specificity, assay linearity, signal-to-noise levels, and fold-changes via CCCD. Next, we defined the assay parameters that are critical for appropriate use of CCCD for different luciferases. To demonstrate the usefulness in cultured mammalian cells, we conducted a case study to examine NFκB gene activation in response to inflammatory signals in human embryonic kidney cells (HEK293 cells). We found that data collected by CCCD camera was equivalent to those acquired by luminometer, thus validating the assay protocol. In comparison, The CCCD-based protocol is readily amenable to live-cell and high-throughput applications, offering fast simultaneous data acquisition and visual and quantitative data presentation. In conclusion, the CCCD-based protocol provides a useful alternative for monitoring luciferase reporters. The wide availability of CCCD will enable more researchers to use luciferases to monitor and quantify biological processes. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Estuarine water quality in parks of the Northeast Coastal and Barrier Network: Development and early implementation of vital signs estuarine nutrient-enrichment monitoring, 2003-06

    USGS Publications Warehouse

    Kopp, Blaine S.; Nielsen, Martha; Glisic, Dejan; Neckles, Hilary A.

    2009-01-01

    This report documents results of pilot tests of a protocol for monitoring estuarine nutrient enrichment for the Vital Signs Monitoring Program of the National Park Service Northeast Coastal and Barrier Network. Data collected from four parks during protocol development in 2003-06 are presented: Gateway National Recreation Area, Colonial National Historic Park, Fire Island National Seashore, and Assateague Island National Seashore. The monitoring approach incorporates several spatial and temporal designs to address questions at a hierarchy of scales. Indicators of estuarine response to nutrient enrichment were sampled using a probability design within park estuaries during a late-summer index period. Monitoring variables consisted of dissolved-oxygen concentration, chlorophyll a concentration, water temperature, salinity, attenuation of downwelling photosynthetically available radiation (PAR), and turbidity. The statistical sampling design allowed the condition of unsampled locations to be inferred from the distribution of data from a set of randomly positioned "probability" stations. A subset of sampling stations was sampled repeatedly during the index period, and stations were not rerandomized in subsequent years. These "trend stations" allowed us to examine temporal variability within the index period, and to improve the sensitivity of the monitoring protocol to detecting change through time. Additionally, one index site in each park was equipped for continuous monitoring throughout the index period. Thus, the protocol includes elements of probabilistic and targeted spatial sampling, and the temporal intensity ranges from snapshot assessments to continuous monitoring.

  2. Building Capacity for a Long-Term, in-Situ, National-Scale Phenology Monitoring Network: Successes, Challenges and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Weltzin, J. F.; Browning, D. M.

    2014-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) is a national-scale science and monitoring initiative focused on phenology - the study of seasonal life-cycle events such as leafing, flowering, reproduction, and migration - as a tool to understand the response of biodiversity to environmental variation and change. USA-NPN provides a hierarchical, national monitoring framework that enables other organizations to leverage the capacity of the Network for their own applications - minimizing investment and duplication of effort - while promoting interoperability. Network participants can leverage: (1) Standardized monitoring protocols that have been broadly vetted, tested and published; (2) A centralized National Phenology Database (NPDb) for maintaining, archiving and replicating data, with standard metadata, terms-of-use, web-services, and documentation of QA/QC, plus tools for discovery, visualization and download of raw data and derived data products; and/or (3) A national in-situ, multi-taxa phenological monitoring system, Nature's Notebook, which enables participants to observe and record phenology of plants and animals - based on the protocols and information management system (IMS) described above - via either web or mobile applications. The protocols, NPDb and IMS, and Nature's Notebook represent a hierarchy of opportunities for involvement by a broad range of interested stakeholders, from individuals to agencies. For example, some organizations have adopted (e.g., the National Ecological Observatory Network or NEON) -- or are considering adopting (e.g., the Long-Term Agroecosystems Network or LTAR) -- the USA-NPN standardized protocols, but will develop their own database and IMS with web services to promote sharing of data with the NPDb. Other organizations (e.g., the Inventory and Monitoring Programs of the National Wildlife Refuge System and the National Park Service) have elected to use Nature's Notebook to support their phenological monitoring programs. We highlight the challenges and benefits of integrating phenology monitoring within existing and emerging national monitoring networks, and showcase opportunities that exist when standardized protocols are adopted and implemented to promote data interoperability and sharing.

  3. A guide to processing bat acoustic data for the North American Bat Monitoring Program (NABat)

    USGS Publications Warehouse

    Reichert, Brian; Lausen, Cori; Loeb, Susan; Weller, Ted; Allen, Ryan; Britzke, Eric; Hohoff, Tara; Siemers, Jeremy; Burkholder, Braden; Herzog, Carl; Verant, Michelle

    2018-06-14

    The North American Bat Monitoring Program (NABat) aims to improve the state of conservation science for all species of bats shared by the United States, Canada, and Mexico. To accomplish this goal, NABat offers guidance and standardized protocols for acoustic monitoring of bats. In this document, “A Guide to Processing Bat Acoustic Data for the North American Bat Monitoring Program (NABat),” we provide general recommendations and specific workflows for the process of identifying bat species from acoustic files recorded using the NABat stationary point and mobile transect acoustic monitoring protocols.

  4. 40 CFR Table 5 to Subpart Ffff of... - Model Rule-Summary of Reporting Requirements

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....3050 and 60.3051. v. If no deviations or malfunctions were reported, a statement that no deviations... 60.3053. v. Dates, times, and causes for monitor downtime incidents; §§ 60.3052 and 60.3053. vi...

  5. 40 CFR Table 5 to Subpart Ffff of... - Model Rule-Summary of Reporting Requirements

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....3050 and 60.3051. v. If no deviations or malfunctions were reported, a statement that no deviations... 60.3053. v. Dates, times, and causes for monitor downtime incidents; §§ 60.3052 and 60.3053. vi...

  6. 40 CFR Table 5 to Subpart Ffff of... - Model Rule-Summary of Reporting Requirements

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....3050 and 60.3051. v. If no deviations or malfunctions were reported, a statement that no deviations... 60.3053. v. Dates, times, and causes for monitor downtime incidents; §§ 60.3052 and 60.3053. vi...

  7. 40 CFR Table 5 to Subpart Ffff of... - Model Rule-Summary of Reporting Requirements

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....3050 and 60.3051. v. If no deviations or malfunctions were reported, a statement that no deviations... 60.3053. v. Dates, times, and causes for monitor downtime incidents; §§ 60.3052 and 60.3053. vi...

  8. 40 CFR Table 5 to Subpart Ffff of... - Model Rule-Summary of Reporting Requirements

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....3050 and 60.3051. v. If no deviations or malfunctions were reported, a statement that no deviations... 60.3053. v. Dates, times, and causes for monitor downtime incidents; §§ 60.3052 and 60.3053. vi...

  9. Brain Monitoring with Electroencephalography and the Electroencephalogram-Derived Bispectral Index During Cardiac Surgery

    PubMed Central

    Kertai, Miklos D.; Whitlock, Elizabeth L.; Avidan, Michael S.

    2011-01-01

    Cardiac surgery presents particular challenges for the anesthesiologist. In addition to standard and advanced monitors typically used during cardiac surgery, anesthesiologists may consider monitoring the brain with raw or processed electroencephalography (EEG). There is strong evidence that a protocol incorporating the processed EEG Bispectral Index (BIS) decreases the incidence intraoperative awareness compared with standard practice. However there is conflicting evidence that incorporating the BIS into cardiac anesthesia practice improves “fast-tracking,” decreases anesthetic drug use, or detects cerebral ischemia. Recent research, including many cardiac surgical patients, shows that a protocol based on BIS monitoring is not superior to a protocol based on end tidal anesthetic concentration monitoring in preventing awareness. There has been a resurgence of interest in the anesthesia literature in limited montage EEG monitoring, including nonproprietary processed indices. This has been accompanied by research showing that with structured training, anesthesiologists can glean useful information from the raw EEG trace. In this review, we discuss both the hypothesized benefits and limitations of BIS and frontal channel EEG monitoring in the cardiac surgical population. PMID:22253267

  10. A Novel Cooperative Opportunistic Routing Scheme for Underwater Sensor Networks

    PubMed Central

    Ghoreyshi, Seyed Mohammad; Shahrabi, Alireza; Boutaleb, Tuleen

    2016-01-01

    Increasing attention has recently been devoted to underwater sensor networks (UWSNs) because of their capabilities in the ocean monitoring and resource discovery. UWSNs are faced with different challenges, the most notable of which is perhaps how to efficiently deliver packets taking into account all of the constraints of the available acoustic communication channel. The opportunistic routing provides a reliable solution with the aid of intermediate nodes’ collaboration to relay a packet toward the destination. In this paper, we propose a new routing protocol, called opportunistic void avoidance routing (OVAR), to address the void problem and also the energy-reliability trade-off in the forwarding set selection. OVAR takes advantage of distributed beaconing, constructs the adjacency graph at each hop and selects a forwarding set that holds the best trade-off between reliability and energy efficiency. The unique features of OVAR in selecting the candidate nodes in the vicinity of each other leads to the resolution of the hidden node problem. OVAR is also able to select the forwarding set in any direction from the sender, which increases its flexibility to bypass any kind of void area with the minimum deviation from the optimal path. The results of our extensive simulation study show that OVAR outperforms other protocols in terms of the packet delivery ratio, energy consumption, end-to-end delay, hop count and traversed distance. PMID:26927118

  11. Three-dimensional quantitative T1 and T2 mapping of the carotid artery: Sequence design and in vivo feasibility.

    PubMed

    Coolen, Bram F; Poot, Dirk H J; Liem, Madieke I; Smits, Loek P; Gao, Shan; Kotek, Gyula; Klein, Stefan; Nederveen, Aart J

    2016-03-01

    A novel three-dimensional (3D) T1 and T2 mapping protocol for the carotid artery is presented. A 3D black-blood imaging sequence was adapted allowing carotid T1 and T2 mapping using multiple flip angles and echo time (TE) preparation times. B1 mapping was performed to correct for spatially varying deviations from the nominal flip angle. The protocol was optimized using simulations and phantom experiments. In vivo scans were performed on six healthy volunteers in two sessions, and in a patient with advanced atherosclerosis. Compensation for patient motion was achieved by 3D registration of the inter/intrasession scans. Subsequently, T1 and T2 maps were obtained by maximum likelihood estimation. Simulations and phantom experiments showed that the bias in T1 and T2 estimation was < 10% within the range of physiological values. In vivo T1 and T2 values for carotid vessel wall were 844 ± 96 and 39 ± 5 ms, with good repeatability across scans. Patient data revealed altered T1 and T2 values in regions of atherosclerotic plaque. The 3D T1 and T2 mapping of the carotid artery is feasible using variable flip angle and variable TE preparation acquisitions. We foresee application of this technique for plaque characterization and monitoring plaque progression in atherosclerotic patients. © 2015 Wiley Periodicals, Inc.

  12. A Novel Cooperative Opportunistic Routing Scheme for Underwater Sensor Networks.

    PubMed

    Ghoreyshi, Seyed Mohammad; Shahrabi, Alireza; Boutaleb, Tuleen

    2016-02-26

    Increasing attention has recently been devoted to underwater sensor networks (UWSNs) because of their capabilities in the ocean monitoring and resource discovery. UWSNs are faced with different challenges, the most notable of which is perhaps how to efficiently deliver packets taking into account all of the constraints of the available acoustic communication channel. The opportunistic routing provides a reliable solution with the aid of intermediate nodes' collaboration to relay a packet toward the destination. In this paper, we propose a new routing protocol, called opportunistic void avoidance routing (OVAR), to address the void problem and also the energy-reliability trade-off in the forwarding set selection. OVAR takes advantage of distributed beaconing, constructs the adjacency graph at each hop and selects a forwarding set that holds the best trade-off between reliability and energy efficiency. The unique features of OVAR in selecting the candidate nodes in the vicinity of each other leads to the resolution of the hidden node problem. OVAR is also able to select the forwarding set in any direction from the sender, which increases its flexibility to bypass any kind of void area with the minimum deviation from the optimal path. The results of our extensive simulation study show that OVAR outperforms other protocols in terms of the packet delivery ratio, energy consumption, end-to-end delay, hop count and traversed distance.

  13. The effect of wheelchair propulsion style on changes in time spent in extreme wrist orientations after a bout of fatiguing propulsion.

    PubMed

    Zukowski, Lisa A; Hass, Chris J; Shechtman, Orit; Christou, Evangelos A; Tillman, Mark D

    2017-10-01

    This study compared how wheelchair propulsion styles affect changes in percentage of time spent in extreme wrist orientations, which have been associated with median nerve injury, after a fatiguing bout of propulsion. Twenty novice, non-disabled adult males learned arcing (ARC) and semicircular (SEMI) propulsion styles and utilised each to perform a wheelchair fatigue protocol. ARC and SEMI did not significantly differ in terms of changes after the fatigue protocol in percentage of time spent in extreme flexion/extension or radial/ulnar deviation at the push phase beginning or end. A pattern was observed, although not significant, of greater increases in percentage of time spent in extreme wrist extension and ulnar deviation during the push phase beginning and ulnar deviation during the push phase end while utilising SEMI relative to ARC. This study evinces that individual differences are greater than observed changes in extreme wrist orientations for both propulsion styles. Practitioner Summary: How wheelchair propulsion styles change with fatigue in terms of extreme wrist orientations was examined. This study evinces that individual differences are greater than observed changes in extreme wrist orientations for both propulsion styles and point towards the need for future research on individual differences utilising propulsion styles.

  14. 21 CFR 58.35 - Quality assurance unit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the corrective actions taken. (5) Determine that no deviations from approved protocols or standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating procedures, and...

  15. 21 CFR 58.35 - Quality assurance unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the corrective actions taken. (5) Determine that no deviations from approved protocols or standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating procedures, and...

  16. 21 CFR 58.35 - Quality assurance unit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the corrective actions taken. (5) Determine that no deviations from approved protocols or standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating procedures, and...

  17. 21 CFR 58.35 - Quality assurance unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the corrective actions taken. (5) Determine that no deviations from approved protocols or standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating procedures, and...

  18. 21 CFR 58.35 - Quality assurance unit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the corrective actions taken. (5) Determine that no deviations from approved protocols or standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating procedures, and...

  19. 40 CFR 63.9340 - How do I demonstrate continuous compliance with the emission limitations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with §§ 63.6(e) and 63.7(e)(1), deviations that occur during a period of SSM of control devices and... deviations that occur during a period of SSM of control devices and associated monitoring equipment are...

  20. 40 CFR 63.9340 - How do I demonstrate continuous compliance with the emission limitations?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with §§ 63.6(e) and 63.7(e)(1), deviations that occur during a period of SSM of control devices and... deviations that occur during a period of SSM of control devices and associated monitoring equipment are...

  1. 40 CFR 63.9340 - How do I demonstrate continuous compliance with the emission limitations?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with §§ 63.6(e) and 63.7(e)(1), deviations that occur during a period of SSM of control devices and... deviations that occur during a period of SSM of control devices and associated monitoring equipment are...

  2. 40 CFR 63.9340 - How do I demonstrate continuous compliance with the emission limitations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with §§ 63.6(e) and 63.7(e)(1), deviations that occur during a period of SSM of control devices and... deviations that occur during a period of SSM of control devices and associated monitoring equipment are...

  3. 40 CFR 63.9340 - How do I demonstrate continuous compliance with the emission limitations?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with §§ 63.6(e) and 63.7(e)(1), deviations that occur during a period of SSM of control devices and... deviations that occur during a period of SSM of control devices and associated monitoring equipment are...

  4. In vivo evaluation of the effect of stimulus distribution on FIR statistical efficiency in event-related fMRI

    PubMed Central

    Jansma, J Martijn; de Zwart, Jacco A; van Gelderen, Peter; Duyn, Jeff H; Drevets, Wayne C; Furey, Maura L

    2013-01-01

    Technical developments in MRI have improved signal to noise, allowing use of analysis methods such as Finite impulse response (FIR) of rapid event related functional MRI (er-fMRI). FIR is one of the most informative analysis methods as it determines onset and full shape of the hemodynamic response function (HRF) without any a-priori assumptions. FIR is however vulnerable to multicollinearity, which is directly related to the distribution of stimuli over time. Efficiency can be optimized by simplifying a design, and restricting stimuli distribution to specific sequences, while more design flexibility necessarily reduces efficiency. However, the actual effect of efficiency on fMRI results has never been tested in vivo. Thus, it is currently difficult to make an informed choice between protocol flexibility and statistical efficiency. The main goal of this study was to assign concrete fMRI signal to noise values to the abstract scale of FIR statistical efficiency. Ten subjects repeated a perception task with five random and m-sequence based protocol, with varying but, according to literature, acceptable levels of multicollinearity. Results indicated substantial differences in signal standard deviation, while the level was a function of multicollinearity. Experiment protocols varied up to 55.4% in standard deviation. Results confirm that quality of fMRI in an FIR analysis can significantly and substantially vary with statistical efficiency. Our in vivo measurements can be used to aid in making an informed decision between freedom in protocol design and statistical efficiency. PMID:23473798

  5. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Yu, Kate; Little, David; Plumb, Rob; Smith, Brian

    2006-01-01

    A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.

  6. Efficacy of predetermined therapeutic measures against bleb-related infection in the Collaborative Bleb-related Infection Incidence and Treatment Study.

    PubMed

    Shoji, Nobuyuki; Arakaki, Yoshikuni; Nakamoto, Kenji; Yamamoto, Tetsuya; Kuwayama, Yasuaki

    2018-03-01

    To report the efficacy of the predetermined treatment protocol of the Collaborative Bleb-related Infection Incidence and Treatment Study (CBIITS) for bleb-related infection (BRI) patients. A prospective, observational cohort study was conducted at 34 clinical centres in Japan. Nineteen eyes from 19 patients that developed BRI were treated using the CBIITS protocol at 34 clinical centres. The visual acuity (VA) and intraocular pressure (IOP) were monitored for 6 and 12 months after treatment with the predetermined protocol. The logMAR was 0.623 ± 0.748 (mean ± standard deviation) before the infection developed. It was 1.054 ± 1.156 and 0.950 ± 1.168 at 6 months and 12 months post-infection, respectively. However, in subgroup analyses, there was no significant decrease in post-infection logMAR in stages I and II. In contrast, decimal VA was decreased ≥2 lines in all four cases in stage III. The IOP did not change after infection. It was 10.2 ± 5.0 mmHg (range, 3-22 mmHg) before the infection developed, and 12.9 ± 5.2 mmHg (5-24 mmHg) and 10.7 ± 4.7 mmHg (3-18 mmHg) at 6 months and 12 months after infection, respectively. Because of the small number of BRI patients, the superiority of the treatment was not definitively determined. However, VA was almost maintained in stages I and II, and the IOP did not change after infection. Although further study is necessary, the treatment protocol shown in the study might be a valuable treatment regime. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Design of MPPT Controller Monitoring Software Based on QT Framework

    NASA Astrophysics Data System (ADS)

    Meng, X. Z.; Lu, P. G.

    2017-10-01

    The MPPT controller was a hardware device for tracking the maximum power point of solar photovoltaic array. Multiple controllers could be working as networking mode by specific communicating protocol. In this article, based on C++ GUI programming with Qt frame, we designed one sort of desktop application for monitoring and analyzing operational parameter of MPPT controller. The type of communicating protocol for building network was Modbus protocol which using Remote Terminal Unit mode and The desktop application of host computer was connected with all the controllers in the network through RS485 communication or ZigBee wireless communication. Using this application, user could monitor the parameter of controller wherever they were by internet.

  8. Quantitative image feature variability amongst CT scanners with a controlled scan protocol

    NASA Astrophysics Data System (ADS)

    Ger, Rachel B.; Zhou, Shouhao; Chi, Pai-Chun Melinda; Goff, David L.; Zhang, Lifei; Lee, Hannah J.; Fuller, Clifton D.; Howell, Rebecca M.; Li, Heng; Stafford, R. Jason; Court, Laurence E.; Mackin, Dennis S.

    2018-02-01

    Radiomics studies often analyze patient computed tomography (CT) images acquired from different CT scanners. This may result in differences in imaging parameters, e.g. different manufacturers, different acquisition protocols, etc. However, quantifiable differences in radiomics features can occur based on acquisition parameters. A controlled protocol may allow for minimization of these effects, thus allowing for larger patient cohorts from many different CT scanners. In order to test radiomics feature variability across different CT scanners a radiomics phantom was developed with six different cartridges encased in high density polystyrene. A harmonized protocol was developed to control for tube voltage, tube current, scan type, pitch, CTDIvol, convolution kernel, display field of view, and slice thickness across different manufacturers. The radiomics phantom was imaged on 18 scanners using the control protocol. A linear mixed effects model was created to assess the impact of inter-scanner variability with decomposition of feature variation between scanners and cartridge materials. The inter-scanner variability was compared to the residual variability (the unexplained variability) and to the inter-patient variability using two different patient cohorts. The patient cohorts consisted of 20 non-small cell lung cancer (NSCLC) and 30 head and neck squamous cell carcinoma (HNSCC) patients. The inter-scanner standard deviation was at least half of the residual standard deviation for 36 of 49 quantitative image features. The ratio of inter-scanner to patient coefficient of variation was above 0.2 for 22 and 28 of the 49 features for NSCLC and HNSCC patients, respectively. Inter-scanner variability was a significant factor compared to patient variation in this small study for many of the features. Further analysis with a larger cohort will allow more thorough analysis with additional variables in the model to truly isolate the interscanner difference.

  9. Nasolabial esthetics in children with complete unilateral cleft lip and palate after 1- versus 3-stage treatment protocols.

    PubMed

    Fudalej, Piotr; Katsaros, Christos; Bongaarts, Catharina; Dudkiewicz, Zofia; Kuijpers-Jagtman, Anne Marie

    2009-08-01

    Facial esthetics play an important role in social interactions. However, children with a repaired complete unilateral cleft lip and palate usually show some disfigurement of the nasolabial area. To date, few studies have assessed the nasolabial appearance after different treatment protocols. The aim of the present study was to compare the nasolabial esthetics after 1- and 3-stage treatment protocols. Four components of the nasolabial appearance (nasal form, nasal deviation, mucocutaneous junction, and profile view) were assessed by 4 raters in 108 consecutively treated children who had undergone either 1-stage closure (Warsaw group, 41 boys and 19 girls, mean age 10.8 years, SD 2.0) or 3-stage (Nijmegen group, 30 boys and 18 girls, mean age 8.9 years, SD 0.7). A 5-grade esthetic index of Asher-McDade was used, in which grade 1 indicates the most esthetic and grade 5 the least esthetic outcome. The nasal form was judged the least esthetic in both groups and graded 3.1 (SD 1.1) and 3.2 (SD 1.1). The nasal deviation, mucocutaneous junction, and profile view were scored from 2.1 (SD 0.8) to 2.3 (SD 1.0) in both groups. The treatment outcome after the Warsaw and Nijmegen protocols was comparable. Neither overall nor any of the 4 components of the nasolabial appearance showed intercenter differences (P > .1). The nasolabial appearance after the Warsaw (1-stage) and Nijmegen (3-stage) protocols was comparable. The technique of lip repair (triangular flap in Warsaw and Millard rotation advancement in Nijmegen) gave comparable results for the esthetics of the nasolabial area.

  10. Impact of uncertain head tissue conductivity in the optimization of transcranial direct current stimulation for an auditory target

    NASA Astrophysics Data System (ADS)

    Schmidt, Christian; Wagner, Sven; Burger, Martin; van Rienen, Ursula; Wolters, Carsten H.

    2015-08-01

    Objective. Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation technique to modify neural excitability. Using multi-array tDCS, we investigate the influence of inter-individually varying head tissue conductivity profiles on optimal electrode configurations for an auditory cortex stimulation. Approach. In order to quantify the uncertainty of the optimal electrode configurations, multi-variate generalized polynomial chaos expansions of the model solutions are used based on uncertain conductivity profiles of the compartments skin, skull, gray matter, and white matter. Stochastic measures, probability density functions, and sensitivity of the quantities of interest are investigated for each electrode and the current density at the target with the resulting stimulation protocols visualized on the head surface. Main results. We demonstrate that the optimized stimulation protocols are only comprised of a few active electrodes, with tolerable deviations in the stimulation amplitude of the anode. However, large deviations in the order of the uncertainty in the conductivity profiles could be noted in the stimulation protocol of the compensating cathodes. Regarding these main stimulation electrodes, the stimulation protocol was most sensitive to uncertainty in skull conductivity. Finally, the probability that the current density amplitude in the auditory cortex target region is supra-threshold was below 50%. Significance. The results suggest that an uncertain conductivity profile in computational models of tDCS can have a substantial influence on the prediction of optimal stimulation protocols for stimulation of the auditory cortex. The investigations carried out in this study present a possibility to predict the probability of providing a therapeutic effect with an optimized electrode system for future auditory clinical and experimental procedures of tDCS applications.

  11. Multichannel infrared fiber optic radiometer for controlled microwave heating

    NASA Astrophysics Data System (ADS)

    Drizlikh, S.; Zur, Albert; Katzir, Abraham

    1990-07-01

    An infrared fiberoptic multichannel radiometer was used for monitoring and controlling the temperature of samples in a microwave heating system. The temperature of water samples was maintained at about 40 °C, with a standard deviation of +/- 0.2°C and a maximum deviation of +/- 0.5°C. The temperature was monitored on the same time at several points on the surface and inside the sample. This novel controlled system is reliable and precise. Such system would be very useful for medical applications such as hypothermia and hyperthermi a.

  12. The Hawaii protocol for scientific monitoring of coffee berry borer: a model for coffee agroecosystems worldwide

    USDA-ARS?s Scientific Manuscript database

    Coffee Berry Borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape...

  13. Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Bouffard, Antonio J.; Garcia, Kathleen; Hamilton, Douglas R.; Van Holsbeeck, Marnix; Ebert, Douglas J. W.; Dulchavsky, Scott A.

    2010-01-01

    Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

  14. The Deep Impact Network Experiment Operations Center Monitor and Control System

    NASA Technical Reports Server (NTRS)

    Wang, Shin-Ywan (Cindy); Torgerson, J. Leigh; Schoolcraft, Joshua; Brenman, Yan

    2009-01-01

    The Interplanetary Overlay Network (ION) software at JPL is an implementation of Delay/Disruption Tolerant Networking (DTN) which has been proposed as an interplanetary protocol to support space communication. The JPL Deep Impact Network (DINET) is a technology development experiment intended to increase the technical readiness of the JPL implemented ION suite. The DINET Experiment Operations Center (EOC) developed by JPL's Protocol Technology Lab (PTL) was critical in accomplishing the experiment. EOC, containing all end nodes of simulated spaces and one administrative node, exercised publish and subscribe functions for payload data among all end nodes to verify the effectiveness of data exchange over ION protocol stacks. A Monitor and Control System was created and installed on the administrative node as a multi-tiered internet-based Web application to support the Deep Impact Network Experiment by allowing monitoring and analysis of the data delivery and statistics from ION. This Monitor and Control System includes the capability of receiving protocol status messages, classifying and storing status messages into a database from the ION simulation network, and providing web interfaces for viewing the live results in addition to interactive database queries.

  15. Serial Interface through Stream Protocol on EPICS Platform for Distributed Control and Monitoring

    NASA Astrophysics Data System (ADS)

    Das Gupta, Arnab; Srivastava, Amit K.; Sunil, S.; Khan, Ziauddin

    2017-04-01

    Remote operation of any equipment or device is implemented in distributed systems in order to control and proper monitoring of process values. For such remote operations, Experimental Physics and Industrial Control System (EPICS) is used as one of the important software tool for control and monitoring of a wide range of scientific parameters. A hardware interface is developed for implementation of EPICS software so that different equipment such as data converters, power supplies, pump controllers etc. could be remotely operated through stream protocol. EPICS base was setup on windows as well as Linux operating system for control and monitoring while EPICS modules such as asyn and stream device were used to interface the equipment with standard RS-232/RS-485 protocol. Stream Device protocol communicates with the serial line with an interface to asyn drivers. Graphical user interface and alarm handling were implemented with Motif Editor and Display Manager (MEDM) and Alarm Handler (ALH) command line channel access utility tools. This paper will describe the developed application which was tested with different equipment and devices serially interfaced to the PCs on a distributed network.

  16. A comparison of methods to assess long-term changes in Sonoran Desert vegetation

    USGS Publications Warehouse

    Munson, S.M.; Webb, R.H.; Hubbard, J.A.

    2011-01-01

    Knowledge about the condition of vegetation cover and composition is critical for assessing the structure and function of ecosystems. To effectively quantify the impacts of a rapidly changing environment, methods to track long-term trends of vegetation must be precise, repeatable, and time- and cost-efficient. Measuring vegetation cover and composition in arid and semiarid regions is especially challenging because vegetation is typically sparse, discontinuous, and individual plants are widely spaced. To meet the goal of long-term vegetation monitoring in the Sonoran Desert and other arid and semiarid regions, we determined how estimates of plant species, total vegetation, and soil cover obtained using a widely-implemented monitoring protocol compared to a more time- and resource-intensive plant census. We also assessed how well this protocol tracked changes in cover through 82 years compared to the plant census. Results from the monitoring protocol were comparable to those from the plant census, despite low and variable plant species cover. Importantly, this monitoring protocol could be used as a rapid, "off-the shelf" tool for assessing land degradation (or desertification) in arid and semiarid ecosystems.

  17. ELISA: Methods and Protocols

    USDA-ARS?s Scientific Manuscript database

    The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...

  18. Unusual anchor pins placement and protocol deviations during computer-based implant placement in a patient with severe mandibular bone atrophy. A case report.

    PubMed

    Pozzi, A; Tallarico, M; Barlattani, A

    2012-06-01

    The aim of the study was to describe an unusual method to stabilize the surgical template during the treatment of a severely resorbed edentulous mandible by means of computer-guided implant surgery. Pre-operative computer-based planning revealed the difficulty to stabilize the surgical template in a 67-year-old healthy woman. A deviation of the original NobelGuide™ protocol was performed to ensure the stability of the surgical template: four anchor pins were used to stabilize the surgical template, two in the buccal side of the anterior template and two unusual pins were placed in the lingual site. Four straight TiUnite® Nobel Biocare™ implants were then placed, according to a modified All-on-4™ concept procedure, to avoid graft procedures and to reduce the cumulative chair-side treatment time and costs. A temporary restoration was placed immediately after implant placement. Three months later a definitive, full acrylic restoration was delivered.

  19. ZeroCal: Automatic MAC Protocol Calibration

    NASA Astrophysics Data System (ADS)

    Meier, Andreas; Woehrle, Matthias; Zimmerling, Marco; Thiele, Lothar

    Sensor network MAC protocols are typically configured for an intended deployment scenario once and for all at compile time. This approach, however, leads to suboptimal performance if the network conditions deviate from the expectations. We present ZeroCal, a distributed algorithm that allows nodes to dynamically adapt to variations in traffic volume. Using ZeroCal, each node autonomously configures its MAC protocol at runtime, thereby trying to reduce the maximum energy consumption among all nodes. While the algorithm is readily usable for any asynchronous low-power listening or low-power probing protocol, we validate and demonstrate the effectiveness of ZeroCal on X-MAC. Extensive testbed experiments and simulations indicate that ZeroCal quickly adapts to traffic variations. We further show that ZeroCal extends network lifetime by 50% compared to an optimal configuration with identical and static MAC parameters at all nodes.

  20. Landbird Monitoring Protocol for National Parks in the North Coast and Cascades Network

    USGS Publications Warehouse

    Siegel, Rodney B.; Wilkerson, Robert L.; Jenkins, Kurt J.; Kuntz, Robert C.; Boetsch, John R.; Schaberl, James P.; Happe, Patricia J.

    2007-01-01

    This protocol narrative outlines the rationale, sampling design and methods for monitoring landbirds in the North Coast and Cascades Network (NCCN) during the breeding season. The NCCN, one of 32 networks of parks in the National Park System, comprises seven national park units in the Pacific Northwest, including three large, mountainous, natural area parks (Mount Rainier [MORA] and Olympic [OLYM] National Parks, North Cascades National Park Service Complex [NOCA]), and four small historic cultural parks (Ebey's Landing National Historical Reserve [EBLA], Lewis and Clark National Historical Park [LEWI], Fort Vancouver National Historical Park [FOVA], and San Juan Island National Historical Park [SAJH]). The protocol reflects decisions made by the NCCN avian monitoring group, which includes NPS representatives from each of the large parks in the Network as well as personnel from the U.S. Geological Survey Forest and Rangeland Ecosystem Science Center (USGS-FRESC) Olympic Field Station, and The Institute for Bird Populations, at meetings held between 2000 (Siegel and Kuntz, 2000) and 2005. The protocol narrative describes the monitoring program in relatively broad terms, and its structure and content adhere to the outline and recommendations developed by Oakley and others (2003) and adopted by NPS. Finer details of the methodology are addressed in a set of standard operating procedures (SOPs) that accompany the protocol narrative. We also provide appendixes containing additional supporting materials that do not clearly belong in either the protocol narrative or the standard operating procedures.

  1. Informal trail monitoring protocols: Denali National Park and Preserve. Final Report, October 2011

    USGS Publications Warehouse

    Marion, Jeffrey L.; Wimpey, Jeremy F.

    2011-01-01

    Managers at Alaska?s Denali National Park and Preserve (DENA) sponsored this research to assess and monitor visitor-created informal trails (ITs). DENA is located in south-central Alaska and managed as a six million acre wilderness park. This program of research was guided by the following objectives: (1) Investigate alternative methods for monitoring the spatial distribution, aggregate lineal extent, and tread conditions of informal (visitor-created) trails within the park. (2) In consultation with park staff, develop, pilot test, and refine cost-effective and scientifically defensible trail monitoring procedures that are fully integrated with the park?s Geographic Information System. (3) Prepare a technical report that compiles and presents research results and their management implications. This report presents the protocol development and field testing process, illustrates the types of data produced by their application, and provides guidance for their application and use. The protocols described provide managers with an efficient means to document and monitor IT conditions in settings ranging from pristine to intensively visited.

  2. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling

    NASA Astrophysics Data System (ADS)

    McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation.

  3. Estimating maize water stress by standard deviation of canopy temperature in thermal imagery

    USDA-ARS?s Scientific Manuscript database

    A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...

  4. Lichen elements as pollution indicators: evaluation of methods for large monitoring programmes

    Treesearch

    Susan Will-Wolf; Sarah Jovan; Michael C. Amacher

    2017-01-01

    Lichen element content is a reliable indicator for relative air pollution load in research and monitoring programmes requiring both efficiency and representation of many sites. We tested the value of costly rigorous field and handling protocols for sample element analysis using five lichen species. No relaxation of rigour was supported; four relaxed protocols generated...

  5. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    PubMed

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  6. Protocol for Landsat-Based Monitoring of Landscape Dynamics at North Coast and Cascades Network Parks

    USGS Publications Warehouse

    Kennedy, Robert E.; Cohen, Warren B.; Kirschbaum, Alan A.; Haunreiter, Erik

    2007-01-01

    Background and Objectives As part of the National Park Service's larger goal of developing long-term monitoring programs in response to the Natural Resource Challenge of 2000, the parks of the North Coast and Cascades Network (NCCN) have determined that monitoring of landscape dynamics is necessary to track ecosystem health (Weber and others, 2005). Landscape dynamics refer to a broad suite of ecological, geomorphological, and anthropogenic processes occurring across broad spatial scales. The NCCN has sought protocols that would leverage remote-sensing technologies to aid in monitoring landscape dynamics.

  7. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.

    PubMed

    Mattu, G S; Perry, T L; Wright, J M

    2001-06-01

    To compare directly the accuracy of the BPM-100(Beta) monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100(Beta) was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100(Beta) and two trained observers (blinded from each other and from the BPM-100(Beta)) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100(Beta) and the mean of two observers (the reference) was determined and expressed as the mean +/- SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100(Beta) monitor and the reference was -0.62 +/- 6.96 mmHg for systolic blood pressure, -1.48 +/- 4.80 mmHg for diastolic blood pressure and 0.14 +/- 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161-165, 2001). The BPM-100(Beta) is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an 'A' grade according to the British Hypertension Society protocol.

  8. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, C. D.; Kron, T.; Leahy, M.

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set wasmore » assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.« less

  9. Real-Time Pretreatment Review Limits Unacceptable Deviations on a Cooperative Group Radiation Therapy Technique Trial: Quality Assurance Results of RTOG 0933

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gondi, Vinai, E-mail: vgondi@chicagocancer.org; University of Wisconsin School of Medicine & Public Health, Madison, Wisconsin; Cui, Yunfeng

    2015-03-01

    Purpose: RTOG 0933 was a phase II trial of hippocampal avoidance during whole brain radiation therapy for patients with brain metastases. The results demonstrated improvement in short-term memory decline, as compared with historical control individuals, and preservation of quality of life. Integral to the conduct of this trial were quality assurance processes inclusive of pre-enrollment credentialing and pretreatment centralized review of enrolled patients. Methods and Materials: Before enrolling patients, all treating physicians and sites were required to successfully complete a “dry-run” credentialing test. The treating physicians were credentialed based on accuracy of magnetic resonance imaging–computed tomography image fusion and hippocampal andmore » normal tissue contouring, and the sites were credentialed based on protocol-specified dosimetric criteria. Using the same criteria, pretreatment centralized review of enrolled patients was conducted. Physicians enrolling 3 consecutive patients without unacceptable deviations were permitted to enroll further patients without pretreatment review, although their cases were reviewed after treatment. Results: In all, 113 physicians and 84 sites were credentialed. Eight physicians (6.8%) failed hippocampal contouring on the first attempt; 3 were approved on the second attempt. Eight sites (9.5%) failed intensity modulated radiation therapy planning on the first attempt; all were approved on the second attempt. One hundred thirteen patients were enrolled in RTOG 0933; 100 were analyzable. Eighty-seven cases were reviewed before treatment; 5 (5.7%) violated the eligibility criteria, and 21 (24%) had unacceptable deviations. With feedback, 18 cases were approved on the second attempt and 2 cases on the third attempt. One patient was treated off protocol. Twenty-two cases were reviewed after treatment; 1 (4.5%) violated the eligibility criteria, and 5 (23%) had unacceptable deviations. Conclusions: Although >95% of the cases passed the pre-enrollment credentialing, the pretreatment centralized review disqualified 5.7% of reviewed cases, prevented unacceptable deviations in 24% of reviewed cases, and limited the final unacceptable deviation rate to 5%. Thus, pretreatment review is deemed necessary in future hippocampal avoidance trials and is potentially useful in other similarly challenging radiation therapy technique trials.« less

  10. Performance of a docking/molecular dynamics protocol for virtual screening of nutlin-class inhibitors of Mdmx.

    PubMed

    Bharatham, Nagakumar; Finch, Kristin E; Min, Jaeki; Mayasundari, Anand; Dyer, Michael A; Guy, R Kiplin; Bashford, Donald

    2017-06-01

    A virtual screening protocol involving docking and molecular dynamics has been tested against the results of fluorescence polarization assays testing the potency of a series of compounds of the nutlin class for inhibition of the interaction between p53 and Mdmx, an interaction identified as a driver of certain cancers. The protocol uses a standard docking method (AutoDock) with a cutoff based on the AutoDock score (ADscore), followed by molecular dynamics simulation with a cutoff based on root-mean-square-deviation (RMSD) from the docked pose. An analysis of the experimental and computational results shows modest performance of ADscore alone, but dramatically improved performance when RMSD is also used. Published by Elsevier Inc.

  11. Detailed analysis of routing protocols with different network limitations

    NASA Astrophysics Data System (ADS)

    Masood, Mohsin; Abuhelala, Mohamed; Glesk, Ivan

    2016-12-01

    In network communication field, routing protocols have got a significant role which are not only used in networks to handle the user data but also to monitor the different network environments. Dynamic routing protocols such as OSPF, EIGRP and RIP are used for forwarding user data to its destination by instantly detecting the dynamic changes across the network. The dynamic changes in the network can be in the form of topological changes, congestions, links failure etc. Therefore, it becomes a challenge to develop and implement dynamic routing protocols that fulfills the network requirements. Hence, each routing protocol has its own characteristics such as convergence activity, routing metric, routing table etc. and will perform differently in various network environments. This paper presents a comprehensive study of static and dynamic routing, along with dynamic routing protocols. Experiments that are conducted under various network limitations are presented using the OPNET tool. The performance of each of dynamic routing protocols are monitored and explained in the form of simulated results using network parameters. The results are analyzed, in order to provide a clear understanding of each protocol performance for the selection of the proper protocol for a given network environment.

  12. A novel Smart Routing Protocol for remote health monitoring in Medical Wireless Networks.

    PubMed

    Sundararajan, T V P; Sumithra, M G; Maheswar, R

    2014-01-01

    In a Medical Wireless Network (MWN), sensors constantly monitor patient's physiological condition and movement. Inter-MWN communications are set up between the Patient Server and one or more Centralized Coordinators. However, MWNs require protocols with little energy consumption and the self-organizing attribute perceived in ad-hoc networks. The proposed Smart Routing Protocol (SRP) selects only the nodes with a higher residual energy and lower traffic density for routing. This approach enhances cooperation among the nodes of a Mobile Ad Hoc Network. Consequently, SRP produces better results than the existing protocols, namely Conditional Min-Max Battery Cost Routing, Min-Max Battery Cost Routing and AdHoc On-demand Distance Vector in terms of network parameters. The performance of the erstwhile schemes for routing protocols is evaluated using the network simulator Qualnet v 4.5.

  13. Direct data access protocols benchmarking on DPM

    NASA Astrophysics Data System (ADS)

    Furano, Fabrizio; Devresse, Adrien; Keeble, Oliver; Mancinelli, Valentina

    2015-12-01

    The Disk Pool Manager is an example of a multi-protocol, multi-VO system for data access on the Grid that went though a considerable technical evolution in the last years. Among other features, its architecture offers the opportunity of testing its different data access frontends under exactly the same conditions, including hardware and backend software. This characteristic inspired the idea of collecting monitoring information from various testbeds in order to benchmark the behaviour of the HTTP and Xrootd protocols for the use case of data analysis, batch or interactive. A source of information is the set of continuous tests that are run towards the worldwide endpoints belonging to the DPM Collaboration, which accumulated relevant statistics in its first year of activity. On top of that, the DPM releases are based on multiple levels of automated testing that include performance benchmarks of various kinds, executed regularly every day. At the same time, the recent releases of DPM can report monitoring information about any data access protocol to the same monitoring infrastructure that is used to monitor the Xrootd deployments. Our goal is to evaluate under which circumstances the HTTP-based protocols can be good enough for batch or interactive data access. In this contribution we show and discuss the results that our test systems have collected under the circumstances that include ROOT analyses using TTreeCache and stress tests on the metadata performance.

  14. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    PubMed Central

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  15. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    PubMed

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  16. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  17. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks

    PubMed Central

    Wang, Jian; Jiang, Shuai; Fapojuwo, Abraham O.

    2017-01-01

    This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks. PMID:28555023

  18. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks.

    PubMed

    Wang, Jian; Jiang, Shuai; Fapojuwo, Abraham O

    2017-05-27

    This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks.

  19. The use of a photoionization detector to detect harmful volatile chemicals by emergency personnel

    PubMed Central

    Patel, Neil D; Fales, William D; Farrell, Robert N

    2009-01-01

    Objective The objective of this investigation was to determine if a photoionization detector (PID) could be used to detect the presence of a simulated harmful chemical on simulated casualties of a chemical release. Methods A screening protocol, based on existing radiation screening protocols, was developed for the purposes of the investigation. Three simulated casualties were contaminated with a simulated chemical agent and two groups of emergency responders were involved in the trials. The success–failure ratio of the participants was used to judge the performance of the PID in this application. Results A high success rate was observed when the screening protocol was properly adhered to (97.67%). Conversely, the success rate suffered when participants deviated from the protocol (86.31%). With one exception, all failures were noted to have been the result of a failure to correctly observe the established screening protocol. Conclusions The results of this investigation indicate that the PID may be an effective screening tool for emergency responders. However, additional study is necessary to both confirm the effectiveness of the PID and refine the screening protocol if necessary. PMID:27147829

  20. In vivo evaluation of the effect of stimulus distribution on FIR statistical efficiency in event-related fMRI.

    PubMed

    Jansma, J Martijn; de Zwart, Jacco A; van Gelderen, Peter; Duyn, Jeff H; Drevets, Wayne C; Furey, Maura L

    2013-05-15

    Technical developments in MRI have improved signal to noise, allowing use of analysis methods such as Finite impulse response (FIR) of rapid event related functional MRI (er-fMRI). FIR is one of the most informative analysis methods as it determines onset and full shape of the hemodynamic response function (HRF) without any a priori assumptions. FIR is however vulnerable to multicollinearity, which is directly related to the distribution of stimuli over time. Efficiency can be optimized by simplifying a design, and restricting stimuli distribution to specific sequences, while more design flexibility necessarily reduces efficiency. However, the actual effect of efficiency on fMRI results has never been tested in vivo. Thus, it is currently difficult to make an informed choice between protocol flexibility and statistical efficiency. The main goal of this study was to assign concrete fMRI signal to noise values to the abstract scale of FIR statistical efficiency. Ten subjects repeated a perception task with five random and m-sequence based protocol, with varying but, according to literature, acceptable levels of multicollinearity. Results indicated substantial differences in signal standard deviation, while the level was a function of multicollinearity. Experiment protocols varied up to 55.4% in standard deviation. Results confirm that quality of fMRI in an FIR analysis can significantly and substantially vary with statistical efficiency. Our in vivo measurements can be used to aid in making an informed decision between freedom in protocol design and statistical efficiency. Published by Elsevier B.V.

  1. 40 CFR 63.9641 - What reports must I submit and when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... provide a statement that there were no deviations from the emission limitations, work practice standards... system was out-of-control during the reporting period. (7) For each deviation from an emission limitation... monitoring system (including a CPMS or COMS) to comply with an emission limitation in this subpart, the...

  2. Estimation of network path segment delays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, Kathleen Marie

    A method for estimation of a network path segment delay includes determining a scaled time stamp for each packet of a plurality of packets by scaling a time stamp for each respective packet to minimize a difference of at least one of a frequency and a frequency drift between a transport protocol clock of a host and a monitoring point. The time stamp for each packet is provided by the transport protocol clock of the host. A corrected time stamp for each packet is determined by removing from the scaled time stamp for each respective packet, a temporal offset betweenmore » the transport protocol clock and the monitoring clock by minimizing a temporal delay variation of the plurality of packets traversing a segment between the host and the monitoring point.« less

  3. Design, development and clinical validation of computer-aided surgical simulation system for streamlined orthognathic surgical planning.

    PubMed

    Yuan, Peng; Mai, Huaming; Li, Jianfu; Ho, Dennis Chun-Yu; Lai, Yingying; Liu, Siting; Kim, Daeseung; Xiong, Zixiang; Alfi, David M; Teichgraeber, John F; Gateno, Jaime; Xia, James J

    2017-12-01

    There are many proven problems associated with traditional surgical planning methods for orthognathic surgery. To address these problems, we developed a computer-aided surgical simulation (CASS) system, the AnatomicAligner, to plan orthognathic surgery following our streamlined clinical protocol. The system includes six modules: image segmentation and three-dimensional (3D) reconstruction, registration and reorientation of models to neutral head posture, 3D cephalometric analysis, virtual osteotomy, surgical simulation, and surgical splint generation. The accuracy of the system was validated in a stepwise fashion: first to evaluate the accuracy of AnatomicAligner using 30 sets of patient data, then to evaluate the fitting of splints generated by AnatomicAligner using 10 sets of patient data. The industrial gold standard system, Mimics, was used as the reference. When comparing the results of segmentation, virtual osteotomy and transformation achieved with AnatomicAligner to the ones achieved with Mimics, the absolute deviation between the two systems was clinically insignificant. The average surface deviation between the two models after 3D model reconstruction in AnatomicAligner and Mimics was 0.3 mm with a standard deviation (SD) of 0.03 mm. All the average surface deviations between the two models after virtual osteotomy and transformations were smaller than 0.01 mm with a SD of 0.01 mm. In addition, the fitting of splints generated by AnatomicAligner was at least as good as the ones generated by Mimics. We successfully developed a CASS system, the AnatomicAligner, for planning orthognathic surgery following the streamlined planning protocol. The system has been proven accurate. AnatomicAligner will soon be available freely to the boarder clinical and research communities.

  4. Prosthetically guided maxillofacial surgery: evaluation of the accuracy of a surgical guide and custom-made bone plate in oncology patients after mandibular reconstruction.

    PubMed

    Mazzoni, Simona; Marchetti, Claudio; Sgarzani, Rossella; Cipriani, Riccardo; Scotti, Roberto; Ciocca, Leonardo

    2013-06-01

    The aim of the present study was to evaluate the accuracy of prosthetically guided maxillofacial surgery in reconstructing the mandible with a free vascularized flap using custom-made bone plates and a surgical guide to cut the mandible and fibula. The surgical protocol was applied in a study group of seven consecutive mandibular-reconstructed patients who were compared with a control group treated using the standard preplating technique on stereolithographic models (indirect computer-aided design/computer-aided manufacturing method). The precision of both surgical techniques (prosthetically guided maxillofacial surgery and indirect computer-aided design/computer-aided manufacturing procedure) was evaluated by comparing preoperative and postoperative computed tomographic data and assessment of specific landmarks. With regard to midline deviation, no significant difference was documented between the test and control groups. With regard to mandibular angle shift, only one left angle shift on the lateral plane showed a statistically significant difference between the groups. With regard to angular deviation of the body axis, the data showed a significant difference in the arch deviation. All patients in the control group registered greater than 8 degrees of deviation, determining a facial contracture of the external profile at the lower margin of the mandible. With regard to condylar position, the postoperative condylar position was better in the test group than in the control group, although no significant difference was detected. The new protocol for mandibular reconstruction using computer-aided design/computer-aided manufacturing prosthetically guided maxillofacial surgery to construct custom-made guides and plates may represent a viable method of reproducing the patient's anatomical contour, giving the surgeon better procedural control and reducing procedure time. Therapeutic, III.

  5. Design, development and clinical validation of computer-aided surgical simulation system for streamlined orthognathic surgical planning

    PubMed Central

    Yuan, Peng; Mai, Huaming; Li, Jianfu; Ho, Dennis Chun-Yu; Lai, Yingying; Liu, Siting; Kim, Daeseung; Xiong, Zixiang; Alfi, David M.; Teichgraeber, John F.; Gateno, Jaime

    2017-01-01

    Purpose There are many proven problems associated with traditional surgical planning methods for orthognathic surgery. To address these problems, we developed a computer-aided surgical simulation (CASS) system, the AnatomicAligner, to plan orthognathic surgery following our streamlined clinical protocol. Methods The system includes six modules: image segmentation and three-dimensional (3D) reconstruction, registration and reorientation of models to neutral head posture, 3D cephalometric analysis, virtual osteotomy, surgical simulation, and surgical splint generation. The accuracy of the system was validated in a stepwise fashion: first to evaluate the accuracy of AnatomicAligner using 30 sets of patient data, then to evaluate the fitting of splints generated by AnatomicAligner using 10 sets of patient data. The industrial gold standard system, Mimics, was used as the reference. Result When comparing the results of segmentation, virtual osteotomy and transformation achieved with AnatomicAligner to the ones achieved with Mimics, the absolute deviation between the two systems was clinically insignificant. The average surface deviation between the two models after 3D model reconstruction in AnatomicAligner and Mimics was 0.3 mm with a standard deviation (SD) of 0.03 mm. All the average surface deviations between the two models after virtual osteotomy and transformations were smaller than 0.01 mm with a SD of 0.01 mm. In addition, the fitting of splints generated by AnatomicAligner was at least as good as the ones generated by Mimics. Conclusion We successfully developed a CASS system, the AnatomicAligner, for planning orthognathic surgery following the streamlined planning protocol. The system has been proven accurate. AnatomicAligner will soon be available freely to the boarder clinical and research communities. PMID:28432489

  6. Level of adherence to an extravasation protocol over 10 years in a tertiary care hospital.

    PubMed

    Molas-Ferrer, Gloria; Farré-Ayuso, Elisabet; doPazo-Oubiña, Fernando; deAndrés-Lázaro, Ana; Guell-Picazo, Jaume; Borrás-Maixenchs, Núria; Corominas-Bosch, Lourdes; Valverde-Bosch, Montserrat; Creus-Baró, Natalia

    2015-04-01

    Extravasation of chemotherapy is an undesirable complication related to the administration of antineoplastic therapy. Establishing the real incidence is difficult. Because of the importance of a quick intervention after an extravasation, every hospital should have an extravasation protocol. The purpose of this study was to determine the degree of observance of an extravasation protocol by nursing staff and to determine extravasation incidence. This descriptive, longitudinal, retrospective study was set in a tertiary-level hospital. The researchers reviewed 117 extravasation notification forms received by the pharmacy department during a 10-year period. Nursing actuation, particularly observance of the extravasation protocol, was analyzed. Protocol adherence was 89%. Twelve deviations from the protocol in the application of recommended measures were detected. An antidote was used in 41 patients, and temperature measures were applied in 14 cases. Ninety-nine patients had at least one episode of reported follow-up. No cases of necrosis or skin ulcers were described, except by one patient, who developed a delayed skin ulcer to vinorelbine. Drugs most frequently reported were etoposide, carboplatin, and paclitaxel. Nursing staff should be continuously trained in extravasation protocol because a rapid actuation can prevent skin lesions.

  7. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    PubMed

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  8. HomeADL for adaptive ADL monitoring within smart homes.

    PubMed

    Hong, Xin; Nugent, Chris D; Finlay, Dewar D; Mulvenna, Maurice

    2008-01-01

    In this paper we present homeADL: a representation standard for an inference hierarchy of activities of daily living which may be monitored in a sensor equipped smart home. The approach allows a free exchange of ADL monitoring structures between different communities who share the same concern of providing high quality healthcare to the elderly. Its ability of matching different ADL protocols enables a mapping between an ADL protocol to a suitable smart home which makes an effective management of smart homes within a community hence, not only being able to satisfy an individual's healthcare requirements but also efficiently using monitoring resources at hand.

  9. A design of wireless sensor networks for a power quality monitoring system.

    PubMed

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  10. Ebola virus disease in a humanitarian aid worker - New York City, October 2014.

    PubMed

    Yacisin, Kari; Balter, Sharon; Fine, Annie; Weiss, Don; Ackelsberg, Joel; Prezant, David; Wilson, Ross; Starr, David; Rakeman, Jennifer; Raphael, Marisa; Quinn, Celia; Toprani, Amita; Clark, Nancy; Link, Nathan; Daskalakis, Demetre; Maybank, Aletha; Layton, Marcelle; Varma, Jay K

    2015-04-03

    In late October 2014, Ebola virus disease (Ebola) was diagnosed in a humanitarian aid worker who recently returned from West Africa to New York City (NYC). The NYC Department of Health and Mental Hygiene (DOHMH) actively monitored three close contacts of the patient and 114 health care personnel. No secondary cases of Ebola were detected. In collaboration with local and state partners, DOHMH had developed protocols to respond to such an event beginning in July 2014. These protocols included safely transporting a person at the first report of symptoms to a local hospital prepared to treat a patient with Ebola, laboratory testing for Ebola, and monitoring of contacts. In response to this single case of Ebola, initial health care worker active monitoring protocols needed modification to improve clarity about what types of exposure should be monitored. The response costs were high in both human resources and money: DOHMH alone spent $4.3 million. However, preparedness activities that include planning and practice in effectively monitoring the health of workers involved in Ebola patient care can help prevent transmission of Ebola.

  11. Network Monitor and Control of Disruption-Tolerant Networks

    NASA Technical Reports Server (NTRS)

    Torgerson, J. Leigh

    2014-01-01

    For nearly a decade, NASA and many researchers in the international community have been developing Internet-like protocols that allow for automated network operations in networks where the individual links between nodes are only sporadically connected. A family of Disruption-Tolerant Networking (DTN) protocols has been developed, and many are reaching CCSDS Blue Book status. A NASA version of DTN known as the Interplanetary Overlay Network (ION) has been flight-tested on the EPOXI spacecraft and ION is currently being tested on the International Space Station. Experience has shown that in order for a DTN service-provider to set up a large scale multi-node network, a number of network monitor and control technologies need to be fielded as well as the basic DTN protocols. The NASA DTN program is developing a standardized means of querying a DTN node to ascertain its operational status, known as the DTN Management Protocol (DTNMP), and the program has developed some prototypes of DTNMP software. While DTNMP is a necessary component, it is not sufficient to accomplish Network Monitor and Control of a DTN network. JPL is developing a suite of tools that provide for network visualization, performance monitoring and ION node control software. This suite of network monitor and control tools complements the GSFC and APL-developed DTN MP software, and the combined package can form the basis for flight operations using DTN.

  12. Validation of the Pangao PG-800B26 upper arm blood pressure monitor in the general population according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Chen, Liang; Li, Jiyu; Wen, Jing; Guo, Changfeng; Zhang, Jingying; Yu, Zhen

    2018-02-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Pangao PG-800B26 for home blood pressure monitoring according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. Systolic and diastolic blood pressures were measured sequentially in 33 and 85 adults, respectively, on the basis of the ESH-IP and BHS protocols using a mercury sphygmomanometer (two observers) and the device (one supervisor). The procedures and analysis methods of the protocols were followed precisely. The device fulfilled the criteria of the ESH-IP, with device-observer differences of 1.01±5.16 and -0.58±4.17 mmHg for systolic and diastolic blood pressure, respectively. Furthermore, the A/A grade of the BHS protocol was also achieved for overall grading and for the three pressure levels, with average differences of 0.85±6.35 and -0.15±5.65 mmHg for systolic and diastolic blood pressure, respectively, which also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800B26 fulfilled the criteria of the ESH-IP 2010 and achieved the A/A grade of the BHS protocol, and hence can be recommended for home use in adults.

  13. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    PubMed

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P < 0.01) and average real variability (P < 0.05) of systolic blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P < 0.001). A positive correlation of serum calcium and parathyroid hormone with 24-h-average real variability of systolic BP was observed in the entire primary hyperparathyroidism patients group (P = 0.04, P  = 0.02; respectively). Systolic blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  14. A survey on temperature-aware routing protocols in wireless body sensor networks.

    PubMed

    Oey, Christian Henry Wijaya; Moh, Sangman

    2013-08-02

    The rapid growth of the elderly population in the world and the rising cost of healthcare impose big issues for healthcare and medical monitoring. A Wireless Body Sensor Network (WBSN) is comprised of small sensor nodes attached inside, on or around a human body, the main purpose of which is to monitor the functions and surroundings of the human body. However, the heat generated by the node's circuitry and antenna could cause damage to the human tissue. Therefore, in designing a routing protocol for WBSNs, it is important to reduce the heat by incorporating temperature into the routing metric. The main contribution of this paper is to survey existing temperature-aware routing protocols that have been proposed for WBSNs. In this paper, we present a brief overview of WBSNs, review the existing routing protocols comparatively and discuss challenging open issues in the design of routing protocols.

  15. A Survey on Temperature-Aware Routing Protocols in Wireless Body Sensor Networks

    PubMed Central

    Oey, Christian Henry Wijaya; Moh, Sangman

    2013-01-01

    The rapid growth of the elderly population in the world and the rising cost of healthcare impose big issues for healthcare and medical monitoring. A Wireless Body Sensor Network (WBSN) is comprised of small sensor nodes attached inside, on or around a human body, the main purpose of which is to monitor the functions and surroundings of the human body. However, the heat generated by the node's circuitry and antenna could cause damage to the human tissue. Therefore, in designing a routing protocol for WBSNs, it is important to reduce the heat by incorporating temperature into the routing metric. The main contribution of this paper is to survey existing temperature-aware routing protocols that have been proposed for WBSNs. In this paper, we present a brief overview of WBSNs, review the existing routing protocols comparatively and discuss challenging open issues in the design of routing protocols. PMID:23917259

  16. Conformal image-guided microbeam radiation therapy at the ESRF biomedical beamline ID17

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donzelli, Mattia, E-mail: donzelli@esrf.fr; Bräuer-Krisch, Elke; Nemoz, Christian

    Purpose: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. Methods: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. Results: Usingmore » four external fiducial markers of 1.7  mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2  mm can be achieved with an angular deviation of less than 2{sup ∘}. Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1  mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. Conclusions: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.« less

  17. Wastewater Biosolid Composting Optimization Based on UV-VNIR Spectroscopy Monitoring.

    PubMed

    Temporal-Lara, Beatriz; Melendez-Pastor, Ignacio; Gómez, Ignacio; Navarro-Pedreño, Jose

    2016-11-15

    Conventional wastewater treatment generates large amounts of organic matter-rich sludge that requires adequate treatment to avoid public health and environmental problems. The mixture of wastewater sludge and some bulking agents produces a biosolid to be composted at adequate composting facilities. The composting process is chemically and microbiologically complex and requires an adequate aeration of the biosolid (e.g., with a turner machine) for proper maturation of the compost. Adequate (near) real-time monitoring of the compost maturity process is highly difficult and the operation of composting facilities is not as automatized as other industrial processes. Spectroscopic analysis of compost samples has been successfully employed for compost maturity assessment but the preparation of the solid compost samples is difficult and time-consuming. This manuscript presents a methodology based on a combination of a less time-consuming compost sample preparation and ultraviolet, visible and short-wave near-infrared spectroscopy. Spectroscopic measurements were performed with liquid compost extract instead of solid compost samples. Partial least square (PLS) models were developed to quantify chemical fractions commonly employed for compost maturity assessment. Effective regression models were obtained for total organic matter (residual predictive deviation-RPD = 2.68), humification ratio (RPD = 2.23), total exchangeable carbon (RPD = 2.07) and total organic carbon (RPD = 1.66) with a modular and cost-effective visible and near infrared (VNIR) spectroradiometer. This combination of a less time-consuming compost sample preparation with a versatile sensor system provides an easy-to-implement, efficient and cost-effective protocol for compost maturity assessment and near-real-time monitoring.

  18. Protocol and Demonstrations of Probabilistic Reliability Assessment for Structural Health Monitoring Systems (Preprint)

    DTIC Science & Technology

    2011-11-01

    assessment to quality of localization/characterization estimates. This protocol includes four critical components: (1) a procedure to identify the...critical factors impacting SHM system performance; (2) a multistage or hierarchical approach to SHM system validation; (3) a model -assisted evaluation...Lindgren, E. A ., Buynak, C. F., Steffes, G., Derriso, M., “ Model -assisted Probabilistic Reliability Assessment for Structural Health Monitoring

  19. Best Management Practices (BMP) Monitoring Manual Field Guide: Implementation and Effectiveness for Protection of Water Resources

    Treesearch

    David Welsch; Roger Ryder; Tim Post

    2006-01-01

    The specific purpose of the BMP protocol is to create an economical, standardized, and repeatable BMP monitoring process that is completely automated, from data gathering through report generation, in order to provide measured data, ease of use, and compatibility with State BMP programs.The protocol was developed to meet the following needs:? Document the use and...

  20. A semi-nested real-time PCR method to detect low chimerism percentage in small quantity of hematopoietic stem cell transplant DNA samples.

    PubMed

    Aloisio, Michelangelo; Bortot, Barbara; Gandin, Ilaria; Severini, Giovanni Maria; Athanasakis, Emmanouil

    2017-02-01

    Chimerism status evaluation of post-allogeneic hematopoietic stem cell transplantation samples is essential to predict post-transplant relapse. The most commonly used technique capable of detecting small increments of chimerism is quantitative real-time PCR. Although this method is already used in several laboratories, previously described protocols often lack sensitivity and the amount of the DNA required for each chimerism analysis is too high. In the present study, we compared a novel semi-nested allele-specific real-time PCR (sNAS-qPCR) protocol with our in-house standard allele-specific real-time PCR (gAS-qPCR) protocol. We selected two genetic markers and analyzed technical parameters (slope, y-intercept, R2, and standard deviation) useful to determine the performances of the two protocols. The sNAS-qPCR protocol showed better sensitivity and precision. Moreover, the sNAS-qPCR protocol requires, as input, only 10 ng of DNA, which is at least 10-fold less than the gAS-qPCR protocols described in the literature. Finally, the proposed sNAS-qPCR protocol could prove very useful for performing chimerism analysis with a small amount of DNA, as in the case of blood cell subsets.

  1. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling.

    PubMed

    McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Operating Systems for Wireless Sensor Networks: A Survey

    PubMed Central

    Farooq, Muhammad Omer; Kunz, Thomas

    2011-01-01

    This paper presents a survey on the current state-of-the-art in Wireless Sensor Network (WSN) Operating Systems (OSs). In recent years, WSNs have received tremendous attention in the research community, with applications in battlefields, industrial process monitoring, home automation, and environmental monitoring, to name but a few. A WSN is a highly dynamic network because nodes die due to severe environmental conditions and battery power depletion. Furthermore, a WSN is composed of miniaturized motes equipped with scarce resources e.g., limited memory and computational abilities. WSNs invariably operate in an unattended mode and in many scenarios it is impossible to replace sensor motes after deployment, therefore a fundamental objective is to optimize the sensor motes’ life time. These characteristics of WSNs impose additional challenges on OS design for WSN, and consequently, OS design for WSN deviates from traditional OS design. The purpose of this survey is to highlight major concerns pertaining to OS design in WSNs and to point out strengths and weaknesses of contemporary OSs for WSNs, keeping in mind the requirements of emerging WSN applications. The state-of-the-art in operating systems for WSNs has been examined in terms of the OS Architecture, Programming Model, Scheduling, Memory Management and Protection, Communication Protocols, Resource Sharing, Support for Real-Time Applications, and additional features. These features are surveyed for both real-time and non-real-time WSN operating systems. PMID:22163934

  3. Operating systems for wireless sensor networks: a survey.

    PubMed

    Farooq, Muhammad Omer; Kunz, Thomas

    2011-01-01

    This paper presents a survey on the current state-of-the-art in Wireless Sensor Network (WSN) Operating Systems (OSs). In recent years, WSNs have received tremendous attention in the research community, with applications in battlefields, industrial process monitoring, home automation, and environmental monitoring, to name but a few. A WSN is a highly dynamic network because nodes die due to severe environmental conditions and battery power depletion. Furthermore, a WSN is composed of miniaturized motes equipped with scarce resources e.g., limited memory and computational abilities. WSNs invariably operate in an unattended mode and in many scenarios it is impossible to replace sensor motes after deployment, therefore a fundamental objective is to optimize the sensor motes' life time. These characteristics of WSNs impose additional challenges on OS design for WSN, and consequently, OS design for WSN deviates from traditional OS design. The purpose of this survey is to highlight major concerns pertaining to OS design in WSNs and to point out strengths and weaknesses of contemporary OSs for WSNs, keeping in mind the requirements of emerging WSN applications. The state-of-the-art in operating systems for WSNs has been examined in terms of the OS Architecture, Programming Model, Scheduling, Memory Management and Protection, Communication Protocols, Resource Sharing, Support for Real-Time Applications, and additional features. These features are surveyed for both real-time and non-real-time WSN operating systems.

  4. Application and analysis of geodetic protocols for monitoring subsidence phenomena along on-shore hydrocarbon reservoirs

    NASA Astrophysics Data System (ADS)

    Montuori, Antonio; Anderlini, Letizia; Palano, Mimmo; Albano, Matteo; Pezzo, Giuseppe; Antoncecchi, Ilaria; Chiarabba, Claudio; Serpelloni, Enrico; Stramondo, Salvatore

    2018-07-01

    In this study, we tested the "land-subsidence monitoring guidelines" proposed by the Italian Ministry of Economic Development (MISE), to study ground deformations along on-shore hydrocarbon reservoirs. We propose protocols that include the joint use of Global Positioning System (GPS) and multi-temporal Differential Interferometric Synthetic Aperture Radar (DInSAR) techniques, for a twofold purpose: a) monitoring land subsidence phenomena along selected areas after defining the background of ground deformations; b) analyzing possible relationships between hydrocarbon exploitation and anomalous deformation patterns. Experimental results, gathered along the Ravenna coastline (northern Italy) and in the southeastern Sicily (southern Italy), show wide areas of subsidence mainly related to natural and anthropogenic processes. Moreover, ground deformations retrieved through multi-temporal DInSAR time series exhibit low sensitivity as well as poor spatial and temporal correlation with hydrocarbon exploitation activities. Results allow evaluating the advantages and limitations of proposed protocols, to improve the techniques and security standards established by MISE guidelines for monitoring on-shore hydrocarbon reservoirs.

  5. Data Sharing to Improve Close Approach Monitoring and Safety of Flight

    NASA Astrophysics Data System (ADS)

    Chan, Joseph; DalBello, Richard; Hope, Dean; Wauthier, Pascal; Douglas, Tim; Inghram, Travis

    2009-03-01

    Individual satellite operators have done a good job of developing the internal protocols and procedures to ensure the safe operation of their fleets. However, data sharing among operators for close approach monitoring is conducted in an ad-hoc manner during relocations, and there is currently no standardized agreement among operators on the content, format, and distribution protocol for data sharing. Crowding in geostationary orbit, participation by new commercial actors, government interest in satellite constellations, and highly maneuverable spacecraft all suggest that satellite operators will need to begin a dialogue on standard communication protocols and procedure to improve situation awareness. We will give an overview of the current best practices among different operators for close approach monitoring and discuss the concept of an active data center to improve data sharing, conjunction monitoring, and avoidance among satellite operators. We will also report on the progress and lessons learned from a Data Center prototype conducted by several operators over a one year period.

  6. SU-F-P-11: Long Term Dosimetric Stability of 6 TomoTherapy Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smilowitz, J; Dunkerley, D; Geurts, M

    2016-06-15

    Purpose: The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Methods: Energy and output were tracked using monitor chamber signal, onboard MVCT detector signal and external ion chamber measurements. The systems (and monitoring periods) include 3 Hi-Art (67, 61 and 65 mos.), 2 HDA (29 and 25 mos.) and one research unit (7 mo.). Dose Control Stability system (DCS) was installed on 4 systems. Output stability is reported as deviation from reference monitor chamber signal for all systems, and from an external chamber for 4 systems. Energy stability wasmore » monitored using the relative (center versus off-axis) MVCT detector signal and/or the ratio of chamber measurements at 2 depths. The results from the clinical systems were used to benchmark the stability of the research unit, which has the same linear accelerator but runs at a higher dose rate. Results: The output based on monitor chamber data of all six systems is very stable. Non- DCS had a standard deviation of 1.7% and 1.8%. As expected, DCS systems had improved standard deviation: 0.003–0.05%. The energy was also very stable for all units. The standard deviation in exit detector flatness was 0.02–0.3%. Ion chamber output and 20/10 cm ratios supported these results. The stability for the research system, as monitored with a variety of metrics, is on par with the existing systems. Conclusion: The output and energy of six TomoTherapy units over a total of almost 10 years is quite stable. For each system, the results are consistent between the different measurement tools and techniques, proving not only the dosimetric stability, but that these quality parameters can be confirmed with various metrics. A research unit operating at a higher dose rate performed as well as the clinical treatment units. University of Wisconsin and Accuray Inc. (vendor of TomoTherapy systems) have a research agreement which supplies funds for research to the University. This project was partially supporting with these funds.« less

  7. TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  8. The importance of within-year repeated counts and the influence of scale on long-term monitoring of sage-grouse

    USGS Publications Warehouse

    Fedy, B.C.; Aldridge, Cameron L.

    2011-01-01

    Long-term population monitoring is the cornerstone of animal conservation and management. The accuracy and precision of models developed using monitoring data can be influenced by the protocols guiding data collection. The greater sage-grouse (Centrocercus urophasianus) is a species of concern that has been monitored over decades, primarily, by counting the number of males that attend lek (breeding) sites. These lek count data have been used to assess long-term population trends and for multiple mechanistic studies. However, some studies have questioned the efficacy of lek counts to accurately identify population trends. In response, monitoring protocols were changed to have a goal of counting lek sites multiple times within a season. We assessed the influence of this change in monitoring protocols on model accuracy and precision applying generalized additive models to describe trends over time. We found that at large spatial scales including >50 leks, the absence of repeated counts within a year did not significantly alter population trend estimates or interpretation. Increasing sample size decreased the model confidence intervals. We developed a population trend model for Wyoming greater sage-grouse from 1965 to 2008, identifying significant changes in the population indices and capturing the cyclic nature of this species. Most sage-grouse declines in Wyoming occurred between 1965 and the 1990s and lek count numbers generally increased from the mid-1990s to 2008. Our results validate the combination of monitoring data collected under different protocols in past and future studies-provided those studies are addressing large-scale questions. We suggest that a larger sample of individual leks is preferable to multiple counts of a smaller sample of leks. ?? 2011 The Wildlife Society.

  9. Protocol to monitor trade agreement food-related aspects: the Fiji case study.

    PubMed

    Ravuvu, Amerita; Friel, Sharon; Thow, Anne Marie; Snowdon, Wendy; Wate, Jillian

    2017-04-26

    Despite the growing rates of obesity and diet-related non-communicable diseases, globally, public health attention has only relatively recently turned to the links between trade agreements and the nutritional risks associated with it. Specific trade agreements appear to have played an influential role in the volume and types of foods entering different countries, yet there is currently no systematic and objective monitoring of trade agreements for their impacts on food environments. Recently, INFORMAS was set up to monitor and benchmark food environments, government policies and private sector actions within countries and globally. One of its projects/modules focuses on trade policy and in particular the food-related aspects of trade agreements. This paper describes the INFORMAS trade protocol, an approach to collecting food-related information about four domains of trade: trade in goods; trade in services and foreign direct investment; domestic supports, and policy space. Specifically, the protocol is tested in Fiji. The development and testing of this protocol in Fiji represents the first effort to set out a framework and process for objectively monitoring trade agreements and their impacts on national food supply and the wider food environment. It has shown that entry into WTO trade agreements contributed to the nutrition transition in Fiji through the increased availability of imported foods with varying nutritional quality. We observed an increase in imports of both healthy and less healthy foods. The application of the monitoring protocol also highlights challenges for data collection associated with each trade domain that should be considered for future data collection and analysis in other low and middle income countries. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Trimodel Mammography with Perfect Coregistration

    DTIC Science & Technology

    2017-02-01

    background, the major confounding factor in reading mammography; the imaging characteristics suggest that this contrast mechanism would be preferable...image with enhanced edges and reduced anatomical background, the major confounding factor in reading mammography; the imaging characteristics suggest...subjects, vertebrate animals , biohazards, and/or select agents Describe significant deviations, unexpected outcomes, or changes in approved protocols

  11. Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru

    2015-04-01

    The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.

  12. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    PubMed

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  13. Report from the NOAA workshops to standardize protocols for monitoring toxic Pfiesteria species and associated environmental conditions.

    PubMed

    Luttenberg, D; Turgeon, D; Higgins, J

    2001-10-01

    Long-term monitoring of water quality, fish health, and plankton communities in susceptible bodies of water is crucial to identify the environmental factors that contribute to outbreaks of toxic Pfiesteria complex (TPC) species. In the aftermath of the 1997 toxic Pfiesteria outbreaks in North Carolina and Maryland, federal and several state agencies agreed that there was a need to standardize monitoring protocols. The National Oceanic & Atmospheric Administration convened two workshops that brought together state, federal, and academic resource managers and scientific experts to a) seek consensus on responding to and monitoring potential toxic Pfiesteria outbreaks; b) recommend standard parameters and protocols to characterize water quality, fish health, and plankton at historical event sites and potentially susceptible sites; and c) discuss options for integrating monitoring data sets from different states into regional and national assessments. Workshop recommendations included the development of a three-tiered TPC monitoring strategy: Tier 1, rapid event response; Tier 2, comprehensive assessment; and Tier 3, routine monitoring. These tiers correspond to varying levels of water quality, fish health, and plankton monitoring frequency and intensity. Under the strategy, sites are prioritized, depending upon their history and susceptibility to TPC events, and assigned an appropriate level of monitoring activity. Participants also agreed upon a suite of water quality parameters that should be monitored. These recommendations provide guidance to state and federal agencies conducting rapid-response and assessment activities at sites of suspected toxic Pfiesteria outbreaks, as well as to states that are developing such monitoring programs for the first time.

  14. Water quality monitoring protocol for wadeable streams and rivers in the Northern Great Plains Network

    USGS Publications Warehouse

    Wilson, Marcia H.; Rowe, Barbara L.; Gitzen, Robert A.; Wilson, Stephen K.; Paintner-Green, Kara J.

    2014-01-01

    As recommended by Oakley et al. (2003), this protocol provides a narrative and the rationale for selection of streams and rivers within the NGPN that will be measured for water quality, including dissolved oxygen, pH, specific conductivity, and temperature. Standard operating procedures (SOPs) that detail the steps to collect, manage, and disseminate the NGPN water quality data are in an accompanying document. The sampling design documented in this protocol may be updated as monitoring information is collected and interpreted, and as refinement of methodologies develop through time. In addition, evaluation of data and refinement of the program may necessitate potential changes of program objectives. Changes to the NGPN water quality protocols and SOPs will be carefully documented in a revision history log.

  15. Time-Series Forecast Modeling on High-Bandwidth Network Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoo, Wucherl; Sim, Alex

    With the increasing number of geographically distributed scientific collaborations and the growing sizes of scientific data, it has become challenging for users to achieve the best possible network performance on a shared network. In this paper, we have developed a model to forecast expected bandwidth utilization on high-bandwidth wide area networks. The forecast model can improve the efficiency of the resource utilization and scheduling of data movements on high-bandwidth networks to accommodate ever increasing data volume for large-scale scientific data applications. A univariate time-series forecast model is developed with the Seasonal decomposition of Time series by Loess (STL) and themore » AutoRegressive Integrated Moving Average (ARIMA) on Simple Network Management Protocol (SNMP) path utilization measurement data. Compared with the traditional approach such as Box-Jenkins methodology to train the ARIMA model, our forecast model reduces computation time up to 92.6 %. It also shows resilience against abrupt network usage changes. Finally, our forecast model conducts the large number of multi-step forecast, and the forecast errors are within the mean absolute deviation (MAD) of the monitored measurements.« less

  16. A novel hapten and monoclonal-based enzyme-linked immunosorbent assay for sulfonamides in edible animal tissues.

    PubMed

    Zhou, Qi; Peng, Dapeng; Wang, Yulian; Pan, Yuanhu; Wan, Dan; Zhang, Xiya; Yuan, Zonghui

    2014-07-01

    For high-throughput monitoring of the residues of sulfonamides (SAs) in edible animal tissues, a novel hapten and monoclonal-based indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was developed. The novel hapten was synthesized and conjugated to carrier protein as immunogen. The spleen cells of the inoculated mice expressing group-specificity against SAs were fused. The obtained monoclonal antibody 4E5 showed the cross-reactivity (CR) to 16 structurally different SAs. Based on this antibody, an optimised icELISA protocol was carried out with only phosphate-buffered saline for the fast extraction of SAs in the tissues. The limits of detection of SAs in chicken ranged from 1.5 to 22.3μgkg(-1). The recoveries were 70.6-121% with less than 24.1% relative standard deviation. The developed ic-ELISA showed a good correlation with high performance liquid chromatography. It would be a useful tool for the screening of residues of SAs in edible animal tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

  18. Directional passive ambient air monitoring of ammonia for fugitive source attribution; a field trial with wind tunnel characteristics

    NASA Astrophysics Data System (ADS)

    Solera García, M. A.; Timmis, R. J.; Van Dijk, N.; Whyatt, J. D.; Leith, I. D.; Leeson, S. R.; Braban, C. F.; Sheppard, L. J.; Sutton, M. A.; Tang, Y. S.

    2017-10-01

    Atmospheric ammonia is a precursor for secondary particulate matter formation, which harms human health and contributes to acidification and eutrophication. Under the 2012 Gothenburg Protocol, 2005 emissions must be cut by 6% by 2020. In the UK, 83% of total emissions originate from agricultural practices such as fertilizer use and rearing of livestock, with emissions that are spatially extensive and variable in nature. Such fugitive emissions make resolving and tracking of individual site performance challenging. The Directional Passive Air quality Sampler (DPAS) was trialled at Whim Bog, an experimental site with a wind-controlled artificial release of ammonia, in combination with CEH-developed ammonia samplers. Whilst saturation issues were identified, two DPAS-MANDE (Mini Annular Denuder) systems, when deployed in parallel, displayed an average relative deviation of 15% (2-54%) across all 12 directions, with the directions exposed to the ammonia source showing ∼5% difference. The DPAS-MANDE has shown great potential for directional discrimination and can contribute to the understanding and management of fugitive ammonia sources from intensive agriculture sites.

  19. Time-Series Forecast Modeling on High-Bandwidth Network Measurements

    DOE PAGES

    Yoo, Wucherl; Sim, Alex

    2016-06-24

    With the increasing number of geographically distributed scientific collaborations and the growing sizes of scientific data, it has become challenging for users to achieve the best possible network performance on a shared network. In this paper, we have developed a model to forecast expected bandwidth utilization on high-bandwidth wide area networks. The forecast model can improve the efficiency of the resource utilization and scheduling of data movements on high-bandwidth networks to accommodate ever increasing data volume for large-scale scientific data applications. A univariate time-series forecast model is developed with the Seasonal decomposition of Time series by Loess (STL) and themore » AutoRegressive Integrated Moving Average (ARIMA) on Simple Network Management Protocol (SNMP) path utilization measurement data. Compared with the traditional approach such as Box-Jenkins methodology to train the ARIMA model, our forecast model reduces computation time up to 92.6 %. It also shows resilience against abrupt network usage changes. Finally, our forecast model conducts the large number of multi-step forecast, and the forecast errors are within the mean absolute deviation (MAD) of the monitored measurements.« less

  20. Sensitive Quantitative Assessment of Balance Disorders

    NASA Technical Reports Server (NTRS)

    Paloski, Willilam H.

    2007-01-01

    Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gould, A.; Yee, J. C.; Pinsonneault, M. H.

    The Galactic bulge source MOA-2010-BLG-523S exhibited short-term deviations from a standard microlensing light curve near the peak of an A {sub max} {approx} 265 high-magnification microlensing event. The deviations originally seemed consistent with expectations for a planetary companion to the principal lens. We combine long-term photometric monitoring with a previously published high-resolution spectrum taken near peak to demonstrate that this is an RS CVn variable, so that planetary microlensing is not required to explain the light-curve deviations. This is the first spectroscopically confirmed RS CVn star discovered in the Galactic bulge.

  2. Monitoring intervention fidelity of a lifestyle behavioral intervention delivered through telehealth

    PubMed Central

    Sineath, Ashley; Lambert, Lauren; Verga, Catherine; Wagstaff, Miranda

    2017-01-01

    Background Technology-based lifestyle behavioral interventions (i.e., telehealth, mHealth, eHealth, and/or digital health) are becoming an alternative standard of care and possess several advantages over traditional clinical settings such as convenience, cost, and the ability to tailor plans and feedback to a participant’s individual needs. These technology-based interventions also present unique challenges to intervention fidelity due to extra elements involved in executing the intervention. Intervention fidelity monitoring is essential to ensure internal and external validity, yet the development and utilization of fidelity protocols is under-reported in the literature. The purpose of this paper is to describe the intervention fidelity protocol for the 24-START study, a behavior change intervention delivered through telephone and internet. This paper also discusses the results of a pilot audit conducted to determine the feasibility of monitoring adherence to the fidelity protocol. Methods The 24-START fidelity protocol was developed in accordance with the five fidelity areas outlined by the NIH Behavior Change Consortium (NIH BCC) including: design of study, provider training, delivery of treatment, receipt of treatment, and enactment of treatment. The fidelity strategies provided by the NIH BCC in each area were tailored to fit the specific design of the 24-START study. Twenty-six total fidelity strategies were developed in accordance with the five areas and a corresponding fidelity monitoring plan was created. Because these strategies are only beneficial if implemented, the fidelity monitoring plan was developed to ensure the fidelity strategies are consistently implemented over the course of the intervention. Results A pilot audit of nine participant files was conducted to test the feasibility of the fidelity protocol developed. Out of the nine participant files reviewed, 89% of scheduled phone calls between a telehealth coach and participant were successfully completed. Of the completed calls, telehealth coaches delivered the intervention as intended 85.3% of the time, and 74% of planned secondary contacts made through the internet were delivered successfully. Additionally, between treatment group dosing was found to be equal. Several weak areas in the fidelity protocol were identified for improvement. The results were satisfactory and the audit was deemed feasible for ongoing use. Conclusions The NIH BCC provides a valuable framework for telehealth interventions to develop fidelity protocols ultimately contributing to improved internal and external validity, better translation of results, increased transparency, and increased opportunities for replication within the field. The 24-START pilot audit found the fidelity protocol efficacious and feasible while also identifying areas of weakness in need of revision. The refined protocol will continue to be utilized throughout the data collection phase. Future telehealth interventions should develop and disclose fidelity protocols to improve the overall quality and standard of telehealth interventions. PMID:28894745

  3. Monitoring intervention fidelity of a lifestyle behavioral intervention delivered through telehealth.

    PubMed

    Sineath, Ashley; Lambert, Lauren; Verga, Catherine; Wagstaff, Miranda; Wingo, Brooks C

    2017-01-01

    Technology-based lifestyle behavioral interventions (i.e., telehealth, mHealth, eHealth, and/or digital health) are becoming an alternative standard of care and possess several advantages over traditional clinical settings such as convenience, cost, and the ability to tailor plans and feedback to a participant's individual needs. These technology-based interventions also present unique challenges to intervention fidelity due to extra elements involved in executing the intervention. Intervention fidelity monitoring is essential to ensure internal and external validity, yet the development and utilization of fidelity protocols is under-reported in the literature. The purpose of this paper is to describe the intervention fidelity protocol for the 24-START study, a behavior change intervention delivered through telephone and internet. This paper also discusses the results of a pilot audit conducted to determine the feasibility of monitoring adherence to the fidelity protocol. The 24-START fidelity protocol was developed in accordance with the five fidelity areas outlined by the NIH Behavior Change Consortium (NIH BCC) including: design of study, provider training, delivery of treatment, receipt of treatment, and enactment of treatment. The fidelity strategies provided by the NIH BCC in each area were tailored to fit the specific design of the 24-START study. Twenty-six total fidelity strategies were developed in accordance with the five areas and a corresponding fidelity monitoring plan was created. Because these strategies are only beneficial if implemented, the fidelity monitoring plan was developed to ensure the fidelity strategies are consistently implemented over the course of the intervention. A pilot audit of nine participant files was conducted to test the feasibility of the fidelity protocol developed. Out of the nine participant files reviewed, 89% of scheduled phone calls between a telehealth coach and participant were successfully completed. Of the completed calls, telehealth coaches delivered the intervention as intended 85.3% of the time, and 74% of planned secondary contacts made through the internet were delivered successfully. Additionally, between treatment group dosing was found to be equal. Several weak areas in the fidelity protocol were identified for improvement. The results were satisfactory and the audit was deemed feasible for ongoing use. The NIH BCC provides a valuable framework for telehealth interventions to develop fidelity protocols ultimately contributing to improved internal and external validity, better translation of results, increased transparency, and increased opportunities for replication within the field. The 24-START pilot audit found the fidelity protocol efficacious and feasible while also identifying areas of weakness in need of revision. The refined protocol will continue to be utilized throughout the data collection phase. Future telehealth interventions should develop and disclose fidelity protocols to improve the overall quality and standard of telehealth interventions.

  4. Reproducibility of geometrical acquisition of intra-thoracic organs of children on CT scans.

    PubMed

    Coulongeat, François; Jarrar, Mohamed-Salah; Serre, Thierry; Thollon, Lionel

    2011-08-01

    This paper analyses geometry of intra-thoracic organs from computed tomography (CT) scans performed on 20 children aged from 4 months to 16 years. A set of two measurements on lungs and heart were performed by the same observer. A third set was performed by a second observer. Thus, the intra- and inter-observer relative deviation of measurements was analysed. Multiple regressions were used in order to study the relationship between the CT properties (scanner, voltage, dose, pixel size, slice increment) and the relative deviation of measurements. There is a very low systematic intra- and inter-observer bias in measurements except for the volume of the heart. None of the CT data properties has a significant influence on the relative deviation of measurement. In the present paper, the measurements and 3D reconstruction protocol described can be applied to characterise the growth of the intra-thoracic organs.

  5. Monitoring the metering performance of an electronic voltage transformer on-line based on cyber-physics correlation analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Zhu; Li, Hongbin; Tang, Dengping; Hu, Chen; Jiao, Yang

    2017-10-01

    Metering performance is the key parameter of an electronic voltage transformer (EVT), and it requires high accuracy. The conventional off-line calibration method using a standard voltage transformer is not suitable for the key equipment in a smart substation, which needs on-line monitoring. In this article, we propose a method for monitoring the metering performance of an EVT on-line based on cyber-physics correlation analysis. By the electrical and physical properties of a substation running in three-phase symmetry, the principal component analysis method is used to separate the metering deviation caused by the primary fluctuation and the EVT anomaly. The characteristic statistics of the measured data during operation are extracted, and the metering performance of the EVT is evaluated by analyzing the change in statistics. The experimental results show that the method successfully monitors the metering deviation of a Class 0.2 EVT accurately. The method demonstrates the accurate evaluation of on-line monitoring of the metering performance on an EVT without a standard voltage transformer.

  6. SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Och, J

    2016-06-15

    Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinicalmore » Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.« less

  7. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  8. Radiotherapy in pediatric medulloblastoma: Quality assessment of Pediatric Oncology Group Trial 9031

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miralbell, Raymond; Fitzgerald, T.J.; Laurie, Fran

    2006-04-01

    Purpose: To evaluate the potential influence of radiotherapy quality on survival in high-risk pediatric medulloblastoma patients. Methods and Materials: Trial 9031 of the Pediatric Oncology Group (POG) aimed to study the relative benefit of cisplatin and etoposide randomization of high-risk patients with medulloblastoma to preradiotherapy vs. postradiotherapy treatment. Two-hundred and ten patients were treated according to protocol guidelines and were eligible for the present analysis. Treatment volume (whole brain, spine, posterior fossa, and primary tumor bed) and dose prescription deviations were assessed for each patient. An analysis of first site of failure was undertaken. Event-free and overall survival rates weremore » calculated. A log-rank test was used to determine the significance of potential survival differences between patients with and without major deviations in the radiotherapy procedure. Results: Of 160 patients who were fully evaluable for all treatment quality parameters, 91 (57%) had 1 or more major deviations in their treatment schedule. Major deviations by treatment site were brain (26%), spinal (7%), posterior fossa (40%), and primary tumor bed (17%). Major treatment volume or total dose deviations did not significantly influence overall and event-free survival. Conclusions: Despite major treatment deviations in more than half of fully evaluable patients, underdosage or treatment volume misses were not associated with a worse event-free or overall survival.« less

  9. Reproductive performance of lactating dairy cows managed for first service using timed artificial insemination with or without detection of estrus using an activity-monitoring system.

    PubMed

    Fricke, P M; Giordano, J O; Valenza, A; Lopes, G; Amundson, M C; Carvalho, P D

    2014-05-01

    Lactating dairy cows (n=1,025) on a commercial dairy farm were randomly assigned at 10 ± 3 d in milk (DIM) to 1 of 3 treatments for submitting cows to first artificial insemination (AI) and were fitted with activity-monitoring tags (Heatime; SCR Engineers Ltd., Netanya, Israel) at 24 ± 3 DIM. Cows (n=339) in treatment 1 were inseminated based on increased activity from the end of the voluntary waiting period (50 DIM) until submission to an Ovsynch protocol; cows without increased activity from 21 to 65 DIM began an Ovsynch protocol at 65 ± 3 DIM, whereas cows without increased activity from 21 to 50 DIM but not from 51 to 79 DIM began an Ovsynch protocol at 79 ± 3 DIM. Cows (n=340) in treatment 2 were inseminated based on activity after the second PGF2α injection of a Presynch-Ovsynch protocol at 50 DIM, and cows without increased activity began an Ovsynch protocol at 65 ± 3 DIM. Cows (n=346) in treatment 3 were monitored for activity after the second PGF2α injection of a Presynch-Ovsynch protocol, but all cows received timed AI (TAI) at 75 ± 3 DIM after completing the Presynch-Ovsynch protocol. The activity-monitoring system detected increased activity in 56, 69, and 70% of cows in treatments 1, 2, and 3, respectively. Treatment-2 cows had the fewest average days to first AI (62.5), treatment-3 cows had the most average days to first AI (74.9), and treatment-1 cows had intermediate average days to first AI (67.4). Treatment-1 and -2 cows in which inseminations occurred as a combination between increased activity and TAI had fewer overall pregnancies per AI (P/AI) 35 d after AI (32% for both treatments) compared with treatment-3 cows, all of which received TAI after completing the Presynch-Ovsynch protocol (40%). Based on survival analysis, although the rate at which cows were inseminated differed among treatments, treatment did not affect the proportion of cows pregnant by 300 DIM. Thus, use of an activity-monitoring system to inseminate cows based on activity reduced days to first AI, whereas cows receiving 100% TAI after completing a Presynch-Ovsynch protocol had more P/AI. The trade-off between AI service rate and P/AI in the rate at which cows became pregnant was supported by an economic analysis in which the net present value ($/cow per year) differed by only $4 to $8 among treatments. We conclude that a variety of strategies using a combination of AI based on increased activity using an activity-monitoring system and synchronization of ovulation and TAI can be used to submit cows for first AI. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of Patient Handoff Methods on an Inpatient Teaching Service

    PubMed Central

    Craig, Steven R.; Smith, Hayden L.; Downen, A. Matthew; Yost, W. John

    2012-01-01

    Background The patient handoff process can be a highly variable and unstructured period at risk for communication errors. The morning sign-in process used by resident physicians at teaching hospitals typically involves less rigorous handoff protocols than the resident evening sign-out process. Little research has been conducted on best practices for handoffs during morning sign-in exchanges between resident physicians. Research must evaluate optimal protocols for the resident morning sign-in process. Methods Three morning handoff protocols consisting of written, electronic, and face-to-face methods were implemented over 3 study phases during an academic year. Study participants included all interns covering the internal medicine inpatient teaching service at a tertiary hospital. Study measures entailed intern survey-based interviews analyzed for failures in handoff protocols with or without missed pertinent information. Descriptive and comparative analyses examined study phase differences. Results A scheduled face-to-face handoff process had the fewest protocol deviations and demonstrated best communication of essential patient care information between cross-covering teams compared to written and electronic sign-in protocols. Conclusion Intern patient handoffs were more reliable when the sign-in protocol included scheduled face-to-face meetings. This method provided the best communication of patient care information and allowed for open exchanges of information. PMID:23267259

  11. Quality assurance of research protocols conducted in the community: the National Institute on Drug Abuse Clinical Trials Network experience.

    PubMed

    Rosa, Carmen; Campbell, Aimee; Kleppinger, Cynthia; Sampson, Royce; Tyson, Clare; Mamay-Gentilin, Stephanie

    2009-04-01

    Quality assurance (QA) of clinical trials is essential to protect the welfare of trial participants and the integrity of the data collected. However, there is little detailed information available on specific procedures and outcomes of QA monitoring for clinical trials. This article describes the experience of the National Institute on Drug Abuse's (NIDA) National Drug Abuse Treatment Clinical Trials Network (CTN) in devising and implementing a three-tiered QA model for rigorous multi-site randomized clinical trials implemented in community-based substance abuse treatment programs. The CTN QA model combined local and national resources and was developed to address the unique needs of clinical trial sites with limited research experience. The authors reviewed internal records maintained by the sponsor, a coordinating site (Lead Nodes), and a local site detailing procedural development, training sessions, protocol violation monitoring, and site visit reporting. Between January 2001 and September 2005, the CTN implemented 21 protocols, of which 18 were randomized clinical trials, one was a quality improvement study and two were surveys. Approximately 160 community-based treatment programs participated in the 19 studies that were monitored, with a total of 6560 participants randomized across the sites. During this time 1937 QA site visits were reported across the three tiers of monitoring and the cost depended on the location of the sites and the salaries of the staff involved. One study reported 109 protocol violations (M = 15.6). Examples are presented to highlight training, protocol violation monitoring, site visit frequency and intensity and cost considerations. : QA data from the entire network were not easily available for review as much of the data were not electronically accessible. The authors reviewed and discussed a representative sample of internal data from the studies and participating sites. The lessons learned from the CTN's experience include the need for balancing thoroughness with efficiency, monitoring early, assessing research staff abilities in order to judge the need for proactive, focused attention, providing targeted training sessions, and developing flexible tools. The CTN model can work for sponsors overseeing studies at sites with limited research experience that require more frequent, in-depth monitoring. We recommend that sponsors not develop a rigid monitoring approach, but work with the study principal investigators to determine the intensity of monitoring needed depending on trial complexity, the risks of the intervention(s), and the experience of the staff with clinical research. After careful evaluation, sponsors should then determine the best approach to site monitoring and what resources will be needed.

  12. Quality assurance of research protocols conducted in the community: The National Institute on Drug Abuse Clinical Trials Network Experience

    PubMed Central

    Rosa, Carmen; Campbell, Aimee; Kleppinger, Cynthia; Sampson, Royce; Tyson, Clare; Mamay-Gentilin, Stephanie

    2009-01-01

    Background: Quality assurance (QA) of clinical trials is essential to protect the welfare of trial participants and the integrity of the data collected. However, there is little detailed information available on specific procedures and outcomes of QA monitoring for clinical trials. Purpose: This article describes the experience of the National Institute on Drug Abuse's (NIDA) National Drug Abuse Treatment Clinical Trials Network (CTN) in devising and implementing a three-tiered QA model for rigorous multi-site randomized clinical trials implemented in community-based substance abuse treatment programs. The CTN QA model combined local and national resources and was developed to address the unique needs of clinical trial sites with limited research experience. Methods: The authors reviewed internal records maintained by the sponsor, a coordinating site (Lead Nodes), and a local site detailing procedural development, training sessions, protocol violation monitoring, and site visit reporting. Results: Between January 2001 and September 2005, the CTN implemented 21 protocols, of which 18 were randomized clinical trials, one was a quality improvement study and two were surveys. Approximately 160 community-based treatment programs participated in the 19 studies that were monitored, with a total of 6560 participants randomized across the sites. During this time 1937 QA site visits were reported across the three tiers of monitoring and the cost depended on the location of the sites and the salaries of the staff involved. One study reported 109 protocol violations (M = 15.6). Examples are presented to highlight training, protocol violation monitoring, site visit frequency and intensity and cost considerations. Limitations: QA data from the entire network were not easily available for review as much of the data were not electronically accessible. The authors reviewed and discussed a representative sample of internal data from the studies and participating sites. Conclusions: The lessons learned from the CTN's experience include the need for balancing thoroughness with efficiency, monitoring early, assessing research staff abilities in order to judge the need for proactive, focused attention, providing targeted training sessions, and developing flexible tools. The CTN model can work for sponsors overseeing studies at sites with limited research experience that require more frequent, in-depth monitoring. We recommend that sponsors not develop a rigid monitoring approach, but work with the study principal investigators to determine the intensity of monitoring needed depending on trial complexity, the risks of the intervention(s), and the experience of the staff with clinical research. After careful evaluation, sponsors should then determine the best approach to site monitoring and what resources will be needed. PMID:19342468

  13. Guidance Protocol: Application of Nucleic Acid-Based Tools for Monitoring Monitored Natural Attenuation (MNA), Biostimulation, and Bioaugmentation at Chlorinated Solvent Sites

    DTIC Science & Technology

    2011-02-01

    Reductive dechlorination is a promising process for biodegradation of chlorinated solvents. The successful field evaluation and implementation of the...population. These specialized bacteria use the chlorinated ethenes as electron acceptors and gain energy for growth from the reductive...This guidance protocol addresses the use of MBTs to quantitatively assess the Dhc population at chlorinated ethene sites and aims at providing

  14. Wildlife feeding in parks: methods for monitoring the effectiveness of educational interventions and wildlife food attraction behaviors

    USGS Publications Warehouse

    Marion, Jeffrey L.; Dvorak, Robert G.; Manning, Robert E.

    2008-01-01

    Opportunities to view and interact with wildlife are often an important part of high quality recreational experiences. Such interactions frequently include wildlife feeding, resulting in food-conditioned behaviors that may cause harm to both wildlife and visitors. This study developed and applied efficient protocols for simultaneously evaluating wildlife feeding-related behaviors of visitors and related foraging behaviors of chipmunks along a trail in Zion National Park. Unobtrusive observation protocols permitted an evaluation of educational messages delivered, and documentation of wildlife success in obtaining human food and the strength of their food attraction behavior. Significant improvements were documented for some targeted visitor behaviors and human food available to chipmunks, with minor differences between treatments. Replication of these protocols as part of a long-term monitoring program can help protected area managers evaluate and improve the efficacy of their interventions and monitor the strength of food attraction behavior in wildlife.

  15. Monitoring protocols: options, approaches, implementation, benefits

    USDA-ARS?s Scientific Manuscript database

    Monitoring and adaptive management are fundamental concepts to rangeland management across land management agencies and embodied as best management practices for private landowners. Historically, rangeland monitoring was limited to determining impacts or maximizing the potential of specific land use...

  16. EPMOSt: An Energy-Efficient Passive Monitoring System for Wireless Sensor Networks

    PubMed Central

    Garcia, Fernando P.; Andrade, Rossana M. C.; Oliveira, Carina T.; de Souza, José Neuman

    2014-01-01

    Monitoring systems are important for debugging and analyzing Wireless Sensor Networks (WSN). In passive monitoring, a monitoring network needs to be deployed in addition to the network to be monitored, named the target network. The monitoring network captures and analyzes packets transmitted by the target network. An energy-efficient passive monitoring system is necessary when we need to monitor a WSN in a real scenario because the lifetime of the monitoring network is extended and, consequently, the target network benefits from the monitoring for a longer time. In this work, we have identified, analyzed and compared the main passive monitoring systems proposed for WSN. During our research, we did not identify any passive monitoring system for WSN that aims to reduce the energy consumption of the monitoring network. Therefore, we propose an Energy-efficient Passive MOnitoring SysTem for WSN named EPMOSt that provides monitoring information using a Simple Network Management Protocol (SNMP) agent. Thus, any management tool that supports the SNMP protocol can be integrated with this monitoring system. Experiments with real sensors were performed in several scenarios. The results obtained show the energy efficiency of the proposed monitoring system and the viability of using it to monitor WSN in real scenarios. PMID:24949639

  17. Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2: 2013 protocols.

    PubMed

    Bing, Sen; Chen, Kang; Hou, Hong; Zhang, Weijuan; Li, Linyi; Wei, Jiao; Shu, Chang; Wan, Yi

    2016-04-01

    This study aimed to determine the accuracy of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors according to the European Society of Hypertension International Protocol revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols. The devices were assessed on 33 participants according to the European Society of Hypertension requirements and were then tested on 85 participants according to the ANSI/AAMI/ISO 81060-2:2013 criteria. Procedures and data analysis were carried out following protocol guidelines precisely. The Microlife BP A200 Comfort and W2 Slim devices passed the criteria of the European Society of Hypertension International Protocol revision 2010 for both systolic blood pressure and diastolic blood pressure. The devices also fulfilled the ANSI/AAMI/ISO 81060-2:2013 criteria, with mean differences of SBP and DPB between the devices and observers of 0.38±5.12 and 0.28±4.29 mmHg for the BP A200 Comfort and 1.01±6.80 and 0.34±5.62 mmHg for the W2 Slim, respectively. The Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors fulfilled the European Society of Hypertension revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols, and can be recommended for self-measurement in the general population.

  18. Review of Quantitative Monitoring Methodologies for Emissions Verification and Accounting for Carbon Dioxide Capture and Storage for California’s Greenhouse Gas Cap-and-Trade and Low-Carbon Fuel Standard Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Curtis M.; Birkholzer, Jens T.

    The Cap-and-Trade and Low Carbon Fuel Standard (LCFS) programs being administered by the California Air Resources Board (CARB) include Carbon Dioxide Capture and Storage (CCS) as a potential means to reduce greenhouse gas (GHG) emissions. However, there is currently no universal standard approach that quantifies GHG emissions reductions for CCS and that is suitable for the quantitative needs of the Cap-and-Trade and LCFS programs. CCS involves emissions related to the capture (e.g., arising from increased energy needed to separate carbon dioxide (CO 2) from a flue gas and compress it for transport), transport (e.g., by pipeline), and storage of COmore » 2 (e.g., due to leakage to the atmosphere from geologic CO 2 storage sites). In this project, we reviewed and compared monitoring, verification, and accounting (MVA) protocols for CCS from around the world by focusing on protocols specific to the geologic storage part of CCS. In addition to presenting the review of these protocols, we highlight in this report those storage-related MVA protocols that we believe are particularly appropriate for CCS in California. We find that none of the existing protocols is completely appropriate for California, but various elements of all of them could be adopted and/or augmented to develop a rigorous, defensible, and practical surface leakage MVA protocol for California. The key features of a suitable surface leakage MVA plan for California are that it: (1) informs and validates the leakage risk assessment, (2) specifies use of the most effective monitoring strategies while still being flexible enough to accommodate special or site-specific conditions, (3) quantifies stored CO 2, and (4) offers defensible estimates of uncertainty in monitored properties. California’s surface leakage MVA protocol needs to be applicable to the main CO 2 storage opportunities (in California and in other states with entities participating in California’s Cap-and-Trade or LCFS programs), specifically CO 2-enhanced oil recovery (CO 2-EOR), CO 2 injection into depleted gas reservoirs (with or without CO 2-enhanced gas recovery (CO 2-EGR)), as well as deep saline storage. Regarding the elements of an effective surface leakage MVA protocol, our recommendations for California are that: (1) both CO 2 and methane (CH 4) surface leakage should be monitored, especially for enhanced recovery scenarios, (2) emissions from all sources not directly related to injection and geologic storage (e.g., from capture, or pipeline transport) should be monitored and reported under a plan separate from the surface leakage MVA plan that is included as another component of the quantification methodology (QM), (3) the primary objective of the surface leakage MVA plan should be to quantify surface leakage of CO 2 and CH 4 and its uncertainty, with consideration of best-practices and state-of-the-art approaches to monitoring including attribution assessment, (4) effort should be made to monitor CO 2 storage and migration in the subsurface to anticipate future surface leakage monitoring needs, (5) detailed descriptions of specific monitoring technologies and approaches should be provided in the MVA plan, (6) the main purpose of the CO 2 injection project (CO 2-EOR, CO 2-EGR, or pure geologic carbon sequestration (GCS)) needs to be stated up front, (7) approaches to dealing with missing data and quantifying uncertainty need to be described, and (8) post-injection monitoring should go on for a period consistent with or longer than that prescribed by the U.S. EPA.« less

  19. Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

    NASA Technical Reports Server (NTRS)

    Grumbach, M. P.; Saxberg, B. E.; Cohen, R. J.

    1987-01-01

    A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

  20. Quantifiable long-term monitoring on parks and nature preserves

    USGS Publications Warehouse

    Beck, Scott; Moorman, Christopher; DePerno, Christopher S.; Simons, Theodore R.

    2013-01-01

    Herpetofauna have declined globally, and monitoring is a useful approach to document local and long-term changes. However, monitoring efforts often fail to account for detectability or follow standardized protocols. We performed a case study at Hemlock Bluffs Nature Preserve in Cary, NC to model occupancy of focal species and demonstrate a replicable long-term protocol useful to parks and nature preserves. From March 2010 to 2011, we documented occupancy of Ambystoma opacum(Marbled Salamander), Plethodon cinereus (Red-backed Salamander), Carphophis amoenus (Eastern Worm Snake), and Diadophis punctatus (Ringneck Snake) at coverboard sites and estimated breeding female Ambystoma maculatum (Spotted Salamander) abundance via dependent double-observer egg-mass counts in ephemeral pools. Temperature influenced detection of both Marbled and Red-backed Salamanders. Based on egg-mass data, we estimated Spotted Salamander abundance to be between 21 and 44 breeding females. We detected 43 of 53 previously documented herpetofauna species. Our approach demonstrates a monitoring protocol that accounts for factors that influence species detection and is replicable by parks or nature preserves with limited resources.

  1. Use of a web-based image reporting and tracking system for assessing abdominal imaging examination quality issues in a single practice.

    PubMed

    Rosenkrantz, Andrew B; Johnson, Evan; Sanger, Joseph J

    2015-10-01

    This article presents our local experience in the implementation of a real-time web-based system for reporting and tracking quality issues relating to abdominal imaging examinations. This system allows radiologists to electronically submit examination quality issues during clinical readouts. The submitted information is e-mailed to a designate for the given modality for further follow-up; the designate may subsequently enter text describing their response or action taken, which is e-mailed back to the radiologist. Review of 558 entries over a 6-year period demonstrated documentation of a broad range of examination quality issues, including specific issues relating to protocol deviation, post-processing errors, positioning errors, artifacts, and IT concerns. The most common issues varied among US, CT, MRI, radiography, and fluoroscopy. In addition, the most common issues resulting in a patient recall for repeat imaging (generally related to protocol deviation in MRI and US) were identified. In addition to submitting quality problems, radiologists also commonly used the tool to provide recognition of a well-performed examination. An electronic log of actions taken in response to radiologists' submissions indicated that both positive and negative feedback were commonly communicated to the performing technologist. Information generated using the tool can be used to guide subsequent quality improvement initiatives within a practice, including continued protocol standardization as well as education of technologists in the optimization of abdominal imaging examinations.

  2. SPP: A data base processor data communications protocol

    NASA Technical Reports Server (NTRS)

    Fishwick, P. A.

    1983-01-01

    The design and implementation of a data communications protocol for the Intel Data Base Processor (DBP) is defined. The protocol is termed SPP (Service Port Protocol) since it enables data transfer between the host computer and the DBP service port. The protocol implementation is extensible in that it is explicitly layered and the protocol functionality is hierarchically organized. Extensive trace and performance capabilities have been supplied with the protocol software to permit optional efficient monitoring of the data transfer between the host and the Intel data base processor. Machine independence was considered to be an important attribute during the design and implementation of SPP. The protocol source is fully commented and is included in Appendix A of this report.

  3. Protocol Gas Verification Program Audit Reports

    EPA Pesticide Factsheets

    View the full reports from 2010 and 2013 of the PGVP audits, which tested the EPA Protocol gases that are used to calibrate continuous emission monitoring systems (CEMS), and the instruments used in EPA reference methods.

  4. Informed Decision Making for In-Home Use of Motion Sensor-Based Monitoring Technologies

    ERIC Educational Resources Information Center

    Bruce, Courtenay R.

    2012-01-01

    Motion sensor-based monitoring technologies are designed to maintain independence and safety of older individuals living alone. These technologies use motion sensors that are placed throughout older individuals' homes in order to derive information about eating, sleeping, and leaving/returning home habits. Deviations from normal behavioral…

  5. PNNI Performance Validation Test Report

    NASA Technical Reports Server (NTRS)

    Dimond, Robert P.

    1999-01-01

    Two Private Network-Network Interface (PNNI) neighboring peers were monitored with a protocol analyzer to understand and document how PNNI works with regards to initialization and recovery processes. With the processes documented, pertinent events were found and measured to determine the protocols behavior in several environments, which consisted of congestion and/or delay. Subsequent testing of the protocol in these environments was conducted to determine the protocol's suitability for use in satellite-terrestrial network architectures.

  6. A combined QC methodology in Ebro Delta HF radar system: real time web monitoring of diagnostic parameters and offline validation of current data

    NASA Astrophysics Data System (ADS)

    Lorente, Pablo; Piedracoba, Silvia; Soto-Navarro, Javier; Ruiz, Maria Isabel; Alvarez Fanjul, Enrique

    2015-04-01

    Over recent years, special attention has been focused on the development of protocols for near real-time quality control (QC) of HF radar derived current measurements. However, no agreement has been worldwide achieved to date to establish a standardized QC methodology, although a number of valuable international initiatives have been launched. In this context, Puertos del Estado (PdE) aims to implement a fully operational HF radar network with four different Codar SeaSonde HF radar systems by means of: - The development of a best-practices robust protocol for data processing and QC procedures to routinely monitor sites performance under a wide variety of ocean conditions. - The execution of validation works with in-situ observations to assess the accuracy of HF radar-derived current measurements. The main goal of the present work is to show this combined methodology for the specific case of Ebro HF radar (although easily expandable to the rest of PdE radar systems), deployed to manage Ebro River deltaic area and promote the conservation of an important aquatic ecosystem exposed to a severe erosion and reshape. To this aim, a web interface has been developed to efficiently monitor in real time the evolution of several diagnostic parameters provided by the manufacturer (CODAR) and used as indicators of HF radar system health. This web, updated automatically every hour, examines sites performance on different time basis in terms of: - Hardware parameters: power and temperature. - Radial parameters, among others: Signal-to-Noise Ratio (SNR), number of radial vectors provided by time step, maximum radial range and bearing. - Total uncertainty metrics provided by CODAR: zonal and meridional standard deviations and covariance between both components. - Additionally, a widget embedded in the web interface executes queries against PdE database, providing the chance to compare current time series observed by Tarragona buoy (located within Ebro HF radar spatial domain) and those measured by the closest radar grid point. A thorough analysis of the temporal evolution of the aforementioned parameters allows to define the standard thresholds for each site within which they are considered to be running optimally. In contrast, a site performance could be categorized as sub-optimal if an erratic and/or anomalous behavior is persistently detected in radial parameters values, related to a significant discrepancy from the mean and clearly outside the limits defined by the associated standard deviations. Consequently, a three colored-based alert system is activated according to each site's current status: green (OK), yellow (acceptable, but issue detected) and red (KO). Since this approach is constrained by the fact that it can not state the intrinsic quality of surface current data, a complementary validation analysis is required: HF radar-derived radial and total vectors are compared with observations from a current meter installed in Tarragona buoy. This validation, conducted for the entire 2014, aims to complete the proposed methodology through the exploration of the existence of bearing errors and the evaluation of intrinsic uncertainties related to HF radar technology by means of objective quality indicators.

  7. Integrated Planning for Telepresence with Time Delays

    NASA Technical Reports Server (NTRS)

    Johnston, Mark D.; Rabe, Kenneth J.

    2006-01-01

    Integrated planning and execution of teleoperations in space with time delays is shown. The topics include: 1) The Problem; 2) Future Robot Surgery? 3) Approach Overview; 4) Robonaut; 5) Normal Planning and Execution; 6) Planner Context; 7) Implementation; 8) Use of JSHOP2; 9) Monitoring and Testing GUI; 10) Normal sequence: first the supervisor acts; 11) then the robot; 12) Robot might be late; 13) Supervisor can work ahead; 14) Deviations from Plan; 15) Robot State Change Example; 16) Accomplished goals skipped in replan; 17) Planning continuity; 18) Supervisor Deviation From Plan; 19) Intentional Deviation; and 20) Infeasible states.

  8. A comparative study of routing protocols of heterogeneous wireless sensor networks.

    PubMed

    Han, Guangjie; Jiang, Xu; Qian, Aihua; Rodrigues, Joel J P C; Cheng, Long

    2014-01-01

    Recently, heterogeneous wireless sensor network (HWSN) routing protocols have drawn more and more attention. Various HWSN routing protocols have been proposed to improve the performance of HWSNs. Among these protocols, hierarchical HWSN routing protocols can improve the performance of the network significantly. In this paper, we will evaluate three hierarchical HWSN protocols proposed recently--EDFCM, MCR, and EEPCA--together with two previous classical routing protocols--LEACH and SEP. We mainly focus on the round of the first node dies (also called the stable period) and the number of packets sent to sink, which is an important aspect to evaluate the monitoring ability of a protocol. We conduct a lot of experiments and simulations on Matlab to analyze the performance of the five routing protocols.

  9. Design and modelling of a link monitoring mechanism for the Common Data Link (CDL)

    NASA Astrophysics Data System (ADS)

    Eichelberger, John W., III

    1994-09-01

    The Common Data Link (CDL) is a full duplex, point-to-point microwave communications system used in imagery and signals intelligence collection systems. It provides a link between two remote Local Area Networks (LAN's) aboard collection and surface platforms. In a hostile environment, there is an overwhelming need to dynamically monitor the link and thus, limit the impact of jamming. This work describes steps taken to design, model, and evaluate a link monitoring system suitable for the CDL. The monitoring system is based on features and monitoring constructs of the Link Control Protocol (LCP) in the Point-to-Point Protocol (PPP) suite. The CDL model is based on a system of two remote Fiber Distributed Data Interface (FDDI) LAN's. In particular, the policies and mechanisms associated with monitoring are described in detail. An implementation of the required mechanisms using the OPNET network engineering tool is described. Performance data related to monitoring parameters is reported. Finally, integration of the FDDI-CDL model with the OPNET Internet model is described.

  10. The management of Convulsive Refractory Status Epilepticus in adults in the UK: No consistency in practice and little access to continuous EEG monitoring.

    PubMed

    Patel, Mitesh; Bagary, Manny; McCorry, Dougall

    2015-01-01

    Convulsive Status Epilepticus (CSE) is a common neurological emergency with patients presenting with prolonged epileptic activity. Sub-optimal management is coupled with high morbidity and mortality. Continuous electroencephalogram (EEG) monitoring is considered essential by the National Institute for Health and Care Excellence (NICE) in the management of Convulsive Refractory Status Epilepticus (CRSE). The aim of this research was to determine current clinical practice in the management of CRSE amongst adults in intensive care units (ICU) in the UK and establish if the use of a standardised protocol requires re-enforcement within trusts. 75 randomly selected UK NHS Trusts were contacted and asked to complete a questionnaire in addition to providing their protocol for CRSE management in ICU. 55 (73%) trusts responded. While 31 (56% of responders) had a protocol available in ICU for early stages of CSE, just 21 (38%) trusts had specific guidelines if CRSE occurred. Only 23 (42%) trusts involved neurologists at any stage of management and just 18 (33%) have access to continuous EEG monitoring. This study identifies significant inconsistency in the management of CSE in ICU's across the UK. A minority of ICU units have a protocol for CRSE or access to continuous EEG monitoring despite it being considered fundamental for management and supported by NICE guidance. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  11. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R. E., E-mail: drzymala@wustl.edu; Alvarez, P. E.; Bednarz, G.

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods:more » Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS dose-rate were 0.999 ± 0.009 (TG-21), 0.991 ± 0.013 (TG-51), 1.000 ± 0.009 (IAEA), and 1.009 ± 0.012 (in-air). There were no statistically significant differences (i.e., p > 0.05) between the two ionization chambers for the TG-21 protocol applied to all dosimetry phantoms. The mean results using the TG-51 protocol were notably lower than those for the other dosimetry protocols, with a standard deviation 2–3 times larger. The in-air protocol was not statistically different from TG-21 for the A16 chamber in the liquid water or ABS phantoms (p = 0.300 and p = 0.135) but was statistically different from TG-21 for the PTW chamber in all phantoms (p = 0.006 for Solid Water, 0.014 for liquid water, and 0.020 for ABS). Results of IAEA formalism were statistically different from TG-21 results only for the combination of the A16 chamber with the liquid water phantom (p = 0.017). In the latter case, dose-rates measured with the two protocols differed by only 0.4%. For other phantom-ionization-chamber combinations, the new IAEA formalism was not statistically different from TG-21. Conclusions: Although further investigation is needed to validate the new protocols for other ionization chambers, these results can serve as a reference to quantitatively compare different calibration protocols and ionization chambers if a particular method is chosen by a professional society to serve as a standardized calibration protocol.« less

  12. [Determination of absorbed dose to water for high energy photon and electron beams--comparison of different dosimetry protocols].

    PubMed

    Zakaria, Golam Abu; Schütte, Wilhelm

    2003-01-01

    The determination of absorbed dose to water for high-energy photon and electron beams is performed in Germany according to the dosimetry protocol DIN 6800-2 (1997). At an international level, the main protocols used are the AAPM dosimetry protocol TG-51 (1999) and the IAEA Code of Practice TRS-398 (2000). The present paper systematically compares these three dosimetry protocols, and identifies similarities and differences. The investigations were performed using 4 and 10 MV photon beams, as well as 6, 8, 9, 10, 12 and 14 MeV electron beams. Two cylindrical and two plane-parallel type chambers were used for measurements. In general, the discrepancies among the three protocols were 1.0% for photon beams and 1.6% for electron beams. Comparative measurements in the context of measurement technical control (MTK) with TLD showed a deviation of less than 1.3% between the measurements obtained according to protocols DIN 6800-2 and MTK (exceptions: 4 MV photons with 2.9% and 6 MeV electrons with 2.4%). While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using both cylindrical and plane-parallel chambers (the latter used after a cross-calibration to a cylindrical chamber, as required by the respective dosimetry protocols). Notably, unlike recommended in the corresponding protocols, we found out that cylindrical chambers can be used also for energies from 6 to 10 MeV.

  13. Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-31

    Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.

  14. Validation of the BPLab(®) 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocol.

    PubMed

    Koudryavtcev, Sergey A; Lazarev, Vyacheslav M

    2011-01-01

    Automatic blood pressure (BP) measuring devices are more and more often used in BP self-checks and in 24-hour BP monitoring. Nowadays, 24-hour BP monitoring is a necessary procedure in arterial hypertension treatment. The aim of this study was to validate the BPLab(®) ambulatory blood pressure monitor according to the European standard BS EN 1060-4:2004 and the British Hypertension Society (BHS) protocol, as well as to work out solutions regarding the suitability of using this device in clinical practice. A group of 85 patients of both sexes and different ages, who voluntarily agreed to take part in the tests and were given detailed instructions on the measurement technique were recruited for this study. The results of the BP measurement obtained by a qualified operator using the BPLab(®) device were compared with the BP values measured using the Korotkov auscultatory method. Data were obtained simultaneously by two experts with experience of over 10 years and had completed a noninvasive BP measurement standardization training course. Discrepancies in the systolic and diastolic BP measurements (N = 510; 255 for each expert) were analyzed according to the criteria specified in the BHS-93 protocol. The device passed the requirements of the European Standard BS EN 1060-4:2004 and was graded 'A' according to the criteria of the BHS protocol for both systolic BP and diastolic BP. The BPLab(®) 24-hour ambulatory blood pressure monitoring device may be recommended for extensive clinical use.

  15. A MAC Protocol for Medical Monitoring Applications of Wireless Body Area Networks

    PubMed Central

    Shu, Minglei; Yuan, Dongfeng; Zhang, Chongqing; Wang, Yinglong; Chen, Changfang

    2015-01-01

    Targeting the medical monitoring applications of wireless body area networks (WBANs), a hybrid medium access control protocol using an interrupt mechanism (I-MAC) is proposed to improve the energy and time slot utilization efficiency and to meet the data delivery delay requirement at the same time. Unlike existing hybrid MAC protocols, a superframe structure with a longer length is adopted to avoid unnecessary beacons. The time slots are mostly allocated to nodes with periodic data sources. Short interruption slots are inserted into the superframe to convey the urgent data and to guarantee the real-time requirements of these data. During these interruption slots, the coordinator can break the running superframe and start a new superframe. A contention access period (CAP) is only activated when there are more data that need to be delivered. Experimental results show the effectiveness of the proposed MAC protocol in WBANs with low urgent traffic. PMID:26046596

  16. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 2: Protocol specification

    NASA Technical Reports Server (NTRS)

    Mckee, James W.

    1990-01-01

    This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.

  17. A low power medium access control protocol for wireless medical sensor networks.

    PubMed

    Lamprinos, I; Prentza, A; Sakka, E; Koutsouris, D

    2004-01-01

    The concept of a wireless integrated network of sensors, already applied in several sectors of our everyday life, such as security, transportation and environment monitoring, can as well provide an advanced monitor and control resource for healthcare services. By networking medical sensors wirelessly, attaching them in patient's body, we create the appropriate infrastructure for continuous and real-time monitoring of patient without discomforting him. This infrastructure can improve healthcare by providing the means for flexible acquisition of vital signs, while at the same time it provides more convenience to the patient. Given the type of wireless network, traditional medium access control (MAC) protocols cannot take advantage of the application specific requirements and information characteristics occurring in medical sensor networks, such as the demand for low power consumption and the rather limited and asymmetric data traffic. In this paper, we present the architecture of a low power MAC protocol, designated to support wireless networks of medical sensors. This protocol aims to improve energy efficiency by exploiting the inherent application features and requirements. It is oriented towards the avoidance of main energy wastage sources, such as idle listening, collision and power outspending.

  18. Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.

    PubMed

    Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes

    The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.

  19. Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driscoll, B.; Keller, H.; Jaffray, D.

    2013-08-15

    Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producingmore » predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.« less

  20. Evaluation of a new chest tube removal protocol using digital air leak monitoring after lobectomy: a prospective randomised trial.

    PubMed

    Brunelli, Alessandro; Salati, Michele; Refai, Majed; Di Nunzio, Luca; Xiumé, Francesco; Sabbatini, Armando

    2010-01-01

    The objective of this randomised trial was to assess the effectiveness of a new fast-track chest tube removal protocol taking advantage of digital monitoring of air leak compared to a traditional protocol using visual and subjective assessment of air leak (bubbles). One hundred and sixty-six patients submitted to pulmonary lobectomy for lung cancer were randomised in two groups with different chest tube removal protocols: (1) in the new protocol, chest tube was removed based on digitally recorded measurements of air leak flow; (2) in the traditional protocol, the chest tube removal was based on an instantaneous assessment of air leak during daily rounds. The two groups were compared in terms of chest tube duration, hospital stay and costs. The two groups were well matched for several preoperative and operative variables. Compared to the traditional protocol, the new digital recording protocol showed mean reductions in chest tube duration (p=0.0007), hospital stay (p=0.007) of 0.9 day, and a mean cost saving of euro 476 per patient (p=0.008). In the new chest tube removal protocol, 51% of patients had their chest tube removed by the second postoperative day versus only 12% of those in the traditional protocol. The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  1. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols

    PubMed Central

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-01-01

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network. PMID:27314351

  2. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols.

    PubMed

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-06-14

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.

  3. A comparison of protocols and observer precision for measuring physical stream attributes

    USGS Publications Warehouse

    Whitacre, H.W.; Roper, B.B.; Kershner, J.L.

    2007-01-01

    Stream monitoring programs commonly measure physical attributes to assess the effect of land management on stream habitat. Variability associated with the measurement of these attributes has been linked to a number of factors, but few studies have evaluated variability due to differences in protocols. We compared six protocols, five used by the U.S. Department of Agriculture Forest Service and one by the U.S. Environmental Protection Agency, on six streams in Oregon and Idaho to determine whether differences in protocol affect values for 10 physical stream attributes. Results from Oregon and Idaho were combined for groups participating in both states, with significant differences in attribute means for 9 out of the 10 stream attributes. Significant differences occurred in 5 of 10 in Idaho, and 10 of 10 in Oregon. Coefficients of variation, signal-to-noise ratio, and root mean square error were used to evaluate measurement precision. There were differences among protocols for all attributes when states were analyzed separately and as a combined dataset. Measurement differences were influenced by choice of instruments, measurement method, measurement location, attribute definitions, and training approach. Comparison of data gathered by observers using different protocols will be difficult unless a core set of protocols for commonly measured stream attributes can be standardized among monitoring programs.

  4. Research on calibration method of downhole optical fiber temperature measurement and its application in SAGD well

    NASA Astrophysics Data System (ADS)

    Lu, Zhiwei; Han, Li; Hu, Chengjun; Pan, Yong; Duan, Shengnan; Wang, Ningbo; Li, Shijian; Nuer, Maimaiti

    2017-10-01

    With the development of oil and gas fields, the accuracy and quantity requirements of real-time dynamic monitoring data needed for well dynamic analysis and regulation are increasing. Permanent, distributed downhole optical fiber temperature and pressure monitoring and other online real-time continuous data monitoring has become an important data acquisition and transmission technology in digital oil field and intelligent oil field construction. Considering the requirement of dynamic analysis of steam chamber developing state in SAGD horizontal wells in F oil reservoir in Xinjiang oilfield, it is necessary to carry out real-time and continuous temperature monitoring in horizontal section. Based on the study of the principle of optical fiber temperature measurement, the factors that cause the deviation of optical fiber temperature sensing are analyzed, and the method of fiber temperature calibration is proposed to solve the problem of temperature deviation. Field application in three wells showed that it could attain accurate measurement of downhole temperature by temperature correction. The real-time and continuous downhole distributed fiber temperature sensing technology has higher application value in the reservoir management of SAGD horizontal wells. It also has a reference for similar dynamic monitoring in reservoir production.

  5. Targeting bed nucleus of the stria terminalis for severe obsessive-compulsive disorder: more unexpected lead placement in obsessive-compulsive disorder than in surgery for movement disorders.

    PubMed

    Nuttin, Bart; Gielen, Frans; van Kuyck, Kris; Wu, Hemmings; Luyten, Laura; Welkenhuysen, Marleen; Brionne, Thomas C; Gabriëls, Loes

    2013-01-01

    In preparation for a multicenter study, a protocol was written on how to perform surgical targeting of the bed nucleus of the stria terminalis, based on the lead implantation experience in patients with treatment-refractory obsessive-compulsive disorder (OCD) at the Universitaire Ziekenhuizen Leuven (UZ Leuven). When analyzing the postoperative images, we were struck by the fact that the difference between the postoperative position of the leads and the planned position seemed larger than expected. The precision of targeting in four patients with severe OCD who received bilateral model 3391 leads (Medtronic) was compared with the precision of targeting in the last seven patients who underwent surgery at UZ Leuven for movement disorders (four with Parkinson disease and three with essential tremor; all received bilateral leads). Because the leads implanted in six of the seven patients with movement disorders were model 3387 leads (Medtronic), targeting precision was also analyzed in four patients with OCD in whom model 3387 leads were implanted in the same target as the other patients with OCD. In the patients with OCD, every implanted lead deviated at least 1.3 mm from its intended position in at least one of three directions (lateral, anteroposterior, and depth), whereas in the patients with movement disorders, the maximal deviation of any of all implanted leads was 1.3 mm. The deviations in lead placement were comparable in patients with OCD who received a model 3387 implant and patients who received a model 3391 implant. In the patients with OCD, all leads were implanted more posteriorly than planned. The cause of the posterior deviation could not be determined with certainty. The most likely cause was an increased mechanical resistance of the brain tissue along the trajectory when following the targeting protocol compared with the trajectories classically used for subthalamic nucleus or ventral intermediate nucleus of the thalamus stimulation. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Mobile Monitoring and Embedded Control System for Factory Environment

    PubMed Central

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-01-01

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones. PMID:24351642

  7. Mobile monitoring and embedded control system for factory environment.

    PubMed

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  8. Informal and formal trail monitoring protocols and baseline conditions: Acadia National Park

    USGS Publications Warehouse

    Marion, Jeffrey L.; Wimpey, Jeremy F.; Park, L.

    2011-01-01

    At Acadia National Park, changing visitor use levels and patterns have contributed to an increasing degree of visitor use impacts to natural and cultural resources. To better understand the extent and severity of these resource impacts and identify effective management techniques, the park sponsored this research to develop monitoring protocols, collect baseline data, and identify suggestions for management strategies. Formal and informal trails were surveyed and their resource conditions were assessed and characterized to support park planning and management decision-making.

  9. The National Riparian Core Protocol: A riparian vegetation monitoring protocol for wadeable streams of the conterminous United States

    Treesearch

    David M. Merritt; Mary E. Manning; Nate Hough-Snee

    2017-01-01

    Riparian areas are hotspots of biological diversity that may serve as high quality habitat for fish and wildlife. The National Riparian Core Protocol (NRCP) provides tools and methods to assist natural resource professionals in sampling riparian vegetation and physical characteristics along wadeable streams. Guidance is provided for collecting basic information on...

  10. Protocols for long-term monitoring of seabird ecology in the Gulf of Alaska

    USGS Publications Warehouse

    Piatt, John F.; Byrd, G. Vernon; Harding, Ann M.A.; Kettle, Arthur B.; Kitaysky, Sasha; Litzow, Michael A.; Roseneau, David G.; Shultz, Michael T.; van Pelt, Thomas I.

    2003-01-01

    Seabird populations will need to be monitored for many years to assess both recovery and ecological conditions affecting recovery. Detailed studies of individual seabird colonies and marine ecosystems in the Gulf of Alaska have been conducted by the U.S. Geological Survey and U.S. Fish and Wildlife Service under the auspices of damage assessment and restoration programs of the Trustee Council. Much has been learned about factors influencing seabird populations and their capacity to recover from the spill in the Gulf of Alaska. As the restoration program moves toward long-term monitoring of populations, however, protocols and long-term monitoring strategies that focus on key parameters of interest and that are inexpensive, practical, and applicable over a large geographic area need to be developed.

  11. A Consensus-Based Interpretation of the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure Trial.

    PubMed

    Chesnut, Randall M; Bleck, Thomas P; Citerio, Giuseppe; Classen, Jan; Cooper, D James; Coplin, William M; Diringer, Michael N; Grände, Per-Olof; Hemphill, J Claude; Hutchinson, Peter J; Le Roux, Peter; Mayer, Stephan A; Menon, David K; Myburgh, John A; Okonkwo, David O; Robertson, Claudia S; Sahuquillo, Juan; Stocchetti, Nino; Sung, Gene; Temkin, Nancy; Vespa, Paul M; Videtta, Walter; Yonas, Howard

    2015-11-15

    Widely-varying published and presented analyses of the Benchmark Evidence From South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial of intracranial pressure (ICP) monitoring have suggested denying trial generalizability, questioning the need for ICP monitoring in severe traumatic brain injury (sTBI), re-assessing current clinical approaches to monitored ICP, and initiating a general ICP-monitoring moratorium. In response to this dissonance, 23 clinically-active, international opinion leaders in acute-care sTBI management met to draft a consensus statement to interpret this study. A Delphi method-based approach employed iterative pre-meeting polling to codify the group's general opinions, followed by an in-person meeting wherein individual statements were refined. Statements required an agreement threshold of more than 70% by blinded voting for approval. Seven precisely-worded statements resulted, with agreement levels of 83% to 100%. These statements, which should be read in toto to properly reflect the group's consensus positions, conclude that the BEST TRIP trial: 1) studied protocols, not ICP-monitoring per se; 2) applies only to those protocols and specific study groups and should not be generalized to other treatment approaches or patient groups; 3) strongly calls for further research on ICP interpretation and use; 4) should be applied cautiously to regions with much different treatment milieu; 5) did not investigate the utility of treating monitored ICP in the specific patient group with established intracranial hypertension; 6) should not change the practice of those currently monitoring ICP; and 7) provided a protocol, used in non-monitored study patients, that should be considered when treating without ICP monitoring. Consideration of these statements can clarify study interpretation.

  12. COMPARISON OF USEPA FIELD SAMPLING METHODS FOR BENTHIC MACROINVERTEBRATE STUDIES

    EPA Science Inventory

    Two U.S. Environmental Protection Agency (USEPA) macroinvertebrate sampling protocols were compared in the Mid-Atlantic Highlands region. The Environmental Monitoring and Assessment Program (EMAP) wadeable streams protocol results in a single composite sample from nine transects...

  13. Monitoring of patients treated with lithium for bipolar disorder: an international survey.

    PubMed

    Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W

    2018-04-14

    Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.

  14. Experimental study on all-fiber-based unidimensional continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Wang, Xuyang; Liu, Wenyuan; Wang, Pu; Li, Yongmin

    2017-06-01

    We experimentally demonstrated an all-fiber-based unidimensional continuous-variable quantum key distribution (CV QKD) protocol and analyzed its security under collective attack in realistic conditions. A pulsed balanced homodyne detector, which could not be accessed by eavesdroppers, with phase-insensitive efficiency and electronic noise, was considered. Furthermore, a modulation method and an improved relative phase-locking technique with one amplitude modulator and one phase modulator were designed. The relative phase could be locked precisely with a standard deviation of 0.5° and a mean of almost zero. Secret key bit rates of 5.4 kbps and 700 bps were achieved for transmission fiber lengths of 30 and 50 km, respectively. The protocol, which simplified the CV QKD system and reduced the cost, displayed a performance comparable to that of a symmetrical counterpart under realistic conditions. It is expected that the developed protocol can facilitate the practical application of the CV QKD.

  15. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    NASA Astrophysics Data System (ADS)

    Thieberger, P.; Gassner, D.; Hulsart, R.; Michnoff, R.; Miller, T.; Minty, M.; Sorrell, Z.; Bartnik, A.

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  16. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE PAGES

    Thieberger, Peter; Gassner, D.; Hulsart, R.; ...

    2018-04-25

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  17. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thieberger, Peter; Gassner, D.; Hulsart, R.

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  18. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets.

    PubMed

    Thieberger, P; Gassner, D; Hulsart, R; Michnoff, R; Miller, T; Minty, M; Sorrell, Z; Bartnik, A

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  19. Performance of fast-setting impression materials in the reproduction of subgingival tooth surfaces without soft tissue retraction.

    PubMed

    Rudolph, Heike; Röhl, Andreas; Walter, Michael H; Luthardt, Ralph G; Quaas, Sebastian

    2014-01-01

    Fast-setting impression materials may be prone to inaccuracies due to accidental divergence from the recommended mixing protocol. This prospective randomized clinical trial aimed to assess three-dimensional (3D) deviations in the reproduction of subgingival tooth surfaces and to determine the effect of either following or purposely diverging from the recommended mixing procedure for a fast-setting addition-curing silicone (AS) and fast-setting polyether (PE). After three impressions each were taken from 96 participants, sawcut gypsum casts were fabricated with a standardized procedure and then optically digitized. Data were assessed with a computer-aided 3D analysis. For AS impressions, multivariate analysis of variance revealed a significant influence of the individual tooth and the degree to which the recommended mixing protocol was violated. For PE impressions, the ambient air temperature and individual tooth showed significant effects, while divergence from the recommended mixing protocol was not of significance. The fast-setting PE material was not affected by changes in the recommended mixing protocol. For the two fast-setting materials examined, no divergences from the recommended mixing protocol of less than 2 minutes led to failures in the reproduction of the subgingival tooth surfaces.

  20. How often are thoughts metacognitive? Findings from research on self-regulated learning, think-aloud protocols, and mind-wandering.

    PubMed

    Jordano, Megan L; Touron, Dayna R

    2018-05-31

    Metacognitive monitoring refers to how people evaluate their cognitive performance. An extensive literature examines how accurately individuals engage in monitoring. The question of how often individuals engage in metacognitive monitoring has been largely neglected, although one might expect situational, group, and individual variability in monitoring frequency. We argue that this is a critical omission, given that the frequency of metacognitive monitoring might have important implications for monitoring accuracy and task performance. Within this review, we highlight findings from three literatures, that each provide insight into how often individuals engage in monitoring. To clarify the important links and potential overlaps between these separate bodies of research, we begin by summarizing the metacognitive monitoring literature, including age-related patterns in monitoring accuracy. We then connect these questions regarding spontaneous monitoring, including age-related patterns in spontaneous monitoring, to targeted reviews of the self-regulated learning, think-aloud protocol, and mind-wandering literatures. We discuss situational and dispositional factors believed to influence monitoring accuracy, and propose that the same factors could potentially influence the frequency of spontaneous monitoring. Additionally, we propose that age-related increases in spontaneous monitoring (as suggested by age-related increases in TRI) may contribute to older adults' intact monitoring abilities. It is our hope that this review will encourage increased attention and research on the topic of spontaneous monitoring.

  1. Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0

    USGS Publications Warehouse

    Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.

    2008-01-01

    The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.

  2. Early Ambulation After Microsurgical Reconstruction of the Lower Extremity.

    PubMed

    Orseck, Michael J; Smith, Christopher Robert; Kirby, Sean; Trujillo, Manuel

    2018-06-01

    Successful outcomes after microsurgical reconstruction of the lower extremity include timely return to ambulation. Some combination of physical examination, ViOptix tissue oxygen saturation monitoring, and the implantable venous Doppler have shown promise in increasing sensitivity of current flap monitoring. We have incorporated this system into our postoperative monitoring protocol in an effort to initiate earlier dependency protocols. A prospective analysis of 36 anterolateral thigh free flap and radial forearm flaps for lower extremity reconstruction was performed. Indications for reconstruction were acute and chronic wounds, as well as oncologic resection. Twenty-three patients were able to ambulate and 3 were able to dangle their leg on the first postoperative day. One flap showed early mottling that improved immediately after elevation. After reelevation and return to baseline, the dependency protocol was successfully implemented on postoperative day 3. All flaps went on to successful healing. Physical examination, implantable venous Doppler, and ViOptix can be used reliably as an adjunct to increase the sensitivity of detecting poorly performing flaps during the postoperative progression of dependency.

  3. [A security protocol for the exchange of personal medical data via Internet: monitoring treatment and drug effects].

    PubMed

    Viviani, R; Fischer, J; Spitzer, M; Freudenmann, R W

    2004-04-01

    We present a security protocol for the exchange of medical data via the Internet, based on the type/domain model. We discuss two applications of the protocol: in a system for the exchange of data for quality assurance, and in an on-line database of adverse reactions to drug use. We state that a type/domain security protocol can successfully comply with the complex requirements for data privacy and accessibility typical of such applications.

  4. Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butner, R. Scott; Reid, Douglas J.; Hoffman, Michael G.

    2013-07-01

    To evaluate the accuracy of NILM technologies, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

  5. An introduction to the Emergency Department Adult Clinical Escalation protocol: ED-ACE.

    PubMed

    Coughlan, Eoin; Geary, Una; Wakai, Abel; O'Sullivan, Ronan; Browne, John; McAuliffe, Eilish; Ward, Marie; McDaid, Fiona; Deasy, Conor

    2017-09-01

    This study demonstrates how a participatory action research approach was used to address the challenge of the early and effective detection of the deteriorating patient in the ED setting. The approach enabled a systematic approach to patient monitoring and escalation of care to be developed to address the wide-ranging spectrum of undifferentiated presentations and the phases of ED care from triage to patient admission. This paper presents a longitudinal patient monitoring system, which aims to provide monitoring and escalation of care, where necessary, of adult patients from triage to admission to hospital in a manner that is feasible in the unique ED environment. An action research approach was taken to designing a longitudinal patient monitoring system appropriate for the ED. While the first draft protocol for post-triage monitoring and escalation was designed by a core research group, six clinical sites were included in iterative cycles of planning, action, reviewing and further planning. Reasons for refining the system at each site were collated and the protocol was adjusted accordingly before commencing the process at the next site. The ED Adult Clinical Escalation longitudinal patient monitoring system (ED-ACE) evolved through iterative cycles of design and testing to include: (1) a monitoring chart for adult patients; (2) a standardised approach to the monitoring and reassessment of patients after triage until they are assessed by a clinician; (3) the ISBAR (I=Identify, S=Situation, B=Background, A=Assessment, R=Recommendation) tool for interprofessional communication relating to clinical escalation; (4) a template for prescribing a patient-specific monitoring plan to be used by treating clinicians to guide patient monitoring from the time the patient is assessed until when they leave the ED and (5) a protocol for clinical escalation prompted by single physiological triggers and clinical concern. This tool offers a link in the 'Chain of Prevention' between the Manchester Triage System and ward-based early warning scores taking account of the importance of standardisation, while being sufficiently adaptable for the unique working environment and patient population in the ED. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. FDA approved drugs complexed to their targets: evaluating pose prediction accuracy of docking protocols.

    PubMed

    Bohari, Mohammed H; Sastry, G Narahari

    2012-09-01

    Efficient drug discovery programs can be designed by utilizing existing pools of knowledge from the already approved drugs. This can be achieved in one way by repositioning of drugs approved for some indications to newer indications. Complex of drug to its target gives fundamental insight into molecular recognition and a clear understanding of putative binding site. Five popular docking protocols, Glide, Gold, FlexX, Cdocker and LigandFit have been evaluated on a dataset of 199 FDA approved drug-target complexes for their accuracy in predicting the experimental pose. Performance for all the protocols is assessed at default settings, with root mean square deviation (RMSD) between the experimental ligand pose and the docked pose of less than 2.0 Å as the success criteria in predicting the pose. Glide (38.7 %) is found to be the most accurate in top ranked pose and Cdocker (58.8 %) in top RMSD pose. Ligand flexibility is a major bottleneck in failure of docking protocols to correctly predict the pose. Resolution of the crystal structure shows an inverse relationship with the performance of docking protocol. All the protocols perform optimally when a balanced type of hydrophilic and hydrophobic interaction or dominant hydrophilic interaction exists. Overall in 16 different target classes, hydrophobic interactions dominate in the binding site and maximum success is achieved for all the docking protocols in nuclear hormone receptor class while performance for the rest of the classes varied based on individual protocol.

  7. Coherent population trapping with a controlled dissipation: applications in optical metrology

    NASA Astrophysics Data System (ADS)

    Nicolas, L.; Delord, T.; Jamonneau, P.; Coto, R.; Maze, J.; Jacques, V.; Hétet, G.

    2018-03-01

    We analyze the properties of a pulsed coherent population trapping protocol that uses a controlled decay from the excited state in a Λ-level scheme. We study this problem analytically and numerically and find regimes where narrow transmission, absorption, or fluorescence spectral lines occur. We then look for optimal frequency measurements using these spectral features by computing the Allan deviation in the presence of ground state decoherence and show that the protocol is on a par with Ramsey-CPT. We discuss possible implementations with ensembles of alkali atoms and single ions and demonstrate that typical pulsed-CPT experiments that are realized on femto-second timescales can be implemented on micro-seconds timescales using this scheme.

  8. Impact of a monitored program of care on incidence of ventilator-associated pneumonia: results of a longterm performance-improvement project.

    PubMed

    Weireter, Leonard J; Collins, J N; Britt, Rebecca C; Reed, Scott F; Novosel, T J; Britt, L D

    2009-05-01

    Ventilator-associated pneumonia (VAP) remains a major source of morbidity, mortality, and expense in the ICU despite therapies directed against it. A retrospective review of a prospectively developed performance-improvement project monitoring the incidence of VAP in two adjacent ICUs was conducted. In response to an excessive VAP rate, weekly multidisciplinary team meetings were instituted to review data, develop care protocols, and modify care routines. Protocol compliance was monitored daily and feedback provided weekly to the care teams. VAP rates were determined by the institutional Infection Control Committee and reviewed monthly with the ICU multidisciplinary team. Duration of the investigational period was 10 years. A standardized ventilator-weaning protocol was instituted with confirmed 95% use. Additional modifications of care, such as patient positioning, use of specific endotracheal tubes to minimize aspiration of supraglottic secretions, an oral-care regimen, and aggressive antibiotic stewardship were standardized, with a compliance rate >90%. VAP rates dropped from 12.8 per 1,000 patient-days in 1998 to 1.1 in 2007 in the burn trauma ICU and from 21.2 to <1 in the neurotrauma ICU in the same time frame. Also, mean ventilator length of stay decreased from 6 days to 4.2 and from 5.8 days to 4.75 simultaneously in the respective ICUs. Such performance improvement has been sustained since implementation of the program. A systematic, monitored program of standardized care protocols can markedly reduce VAP rate in the ICU.

  9. Secure Authentication for Remote Patient Monitoring with Wireless Medical Sensor Networks †

    PubMed Central

    Hayajneh, Thaier; Mohd, Bassam J; Imran, Muhammad; Almashaqbeh, Ghada; Vasilakos, Athanasios V.

    2016-01-01

    There is broad consensus that remote health monitoring will benefit all stakeholders in the healthcare system and that it has the potential to save billions of dollars. Among the major concerns that are preventing the patients from widely adopting this technology are data privacy and security. Wireless Medical Sensor Networks (MSNs) are the building blocks for remote health monitoring systems. This paper helps to identify the most challenging security issues in the existing authentication protocols for remote patient monitoring and presents a lightweight public-key-based authentication protocol for MSNs. In MSNs, the nodes are classified into sensors that report measurements about the human body and actuators that receive commands from the medical staff and perform actions. Authenticating these commands is a critical security issue, as any alteration may lead to serious consequences. The proposed protocol is based on the Rabin authentication algorithm, which is modified in this paper to improve its signature signing process, making it suitable for delay-sensitive MSN applications. To prove the efficiency of the Rabin algorithm, we implemented the algorithm with different hardware settings using Tmote Sky motes and also programmed the algorithm on an FPGA to evaluate its design and performance. Furthermore, the proposed protocol is implemented and tested using the MIRACL (Multiprecision Integer and Rational Arithmetic C/C++) library. The results show that secure, direct, instant and authenticated commands can be delivered from the medical staff to the MSN nodes. PMID:27023540

  10. Secure Authentication for Remote Patient Monitoring with Wireless Medical Sensor Networks.

    PubMed

    Hayajneh, Thaier; Mohd, Bassam J; Imran, Muhammad; Almashaqbeh, Ghada; Vasilakos, Athanasios V

    2016-03-24

    There is broad consensus that remote health monitoring will benefit all stakeholders in the healthcare system and that it has the potential to save billions of dollars. Among the major concerns that are preventing the patients from widely adopting this technology are data privacy and security. Wireless Medical Sensor Networks (MSNs) are the building blocks for remote health monitoring systems. This paper helps to identify the most challenging security issues in the existing authentication protocols for remote patient monitoring and presents a lightweight public-key-based authentication protocol for MSNs. In MSNs, the nodes are classified into sensors that report measurements about the human body and actuators that receive commands from the medical staff and perform actions. Authenticating these commands is a critical security issue, as any alteration may lead to serious consequences. The proposed protocol is based on the Rabin authentication algorithm, which is modified in this paper to improve its signature signing process, making it suitable for delay-sensitive MSN applications. To prove the efficiency of the Rabin algorithm, we implemented the algorithm with different hardware settings using Tmote Sky motes and also programmed the algorithm on an FPGA to evaluate its design and performance. Furthermore, the proposed protocol is implemented and tested using the MIRACL (Multiprecision Integer and Rational Arithmetic C/C++) library. The results show that secure, direct, instant and authenticated commands can be delivered from the medical staff to the MSN nodes.

  11. Research on a Banknote Printing Wastewater Monitoring System based on Wireless Sensor Network

    NASA Astrophysics Data System (ADS)

    Li, B. B.; Yuan, Z. F.

    2006-10-01

    In this paper, a banknote printing wastewater monitoring system based on WSN is presented in line with the system demands and actual condition of the worksite for a banknote printing factory. In Physical Layer, the network node is a nRF9e5-centric embedded instrument, which can realize the multi-function such as data collecting, status monitoring, wireless data transmission and so on. Limited by the computing capability, memory capability, communicating energy and others factors, it is impossible for the node to get every detail information of the network, so the communication protocol on WSN couldn't be very complicated. The competitive-based MACA (Multiple Access with Collision Avoidance) Protocol is introduced in MAC, which can decide the communication process and working mode of the nodes, avoid the collision of data transmission, hidden and exposed station problem of nodes. On networks layer, the routing protocol in charge of the transmitting path of the data, the networks topology structure is arranged based on address assignation. Accompanied with some redundant nodes, the network performances stabile and expandable. The wastewater monitoring system is a tentative practice of WSN theory in engineering. Now, the system has passed test and proved efficiently.

  12. The Hawaii Protocol for Scientific Monitoring of Coffee Berry Borer: a Model for Coffee Agroecosystems Worldwide

    PubMed Central

    Johnson, Melissa Anne; Hollingsworth, Robert; Fortna, Samuel; Aristizábal, Luis F.; Manoukis, Nicholas C.

    2018-01-01

    Coffee berry borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol that is aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape. The cornerstone of this comprehensive monitoring system is timely georeferenced data collection on CBB movement, coffee berry infestation, mortality by the fungus Beauveria bassiana, and coffee plant phenology via a mobile electronic data recording application. This electronic data collection system allows field records to be georeferenced through built-in global positioning systems, and is backed by a network of weather stations and records of farm management practices. Comprehensive monitoring of CBB and host plant dynamics is an essential part of an area-wide project in Hawaii to aggregate landscape-level data for research to improve management practices. Coffee agroecosystems in other parts of the world that experience highly variable environmental and socioeconomic factors will also benefit from implementing this protocol, in that it will drive the development of customized integrated pest management (IPM) to manage CBB populations. PMID:29608152

  13. The Hawaii Protocol for Scientific Monitoring of Coffee Berry Borer: a Model for Coffee Agroecosystems Worldwide.

    PubMed

    Johnson, Melissa Anne; Hollingsworth, Robert; Fortna, Samuel; Aristizábal, Luis F; Manoukis, Nicholas C

    2018-03-19

    Coffee berry borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol that is aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape. The cornerstone of this comprehensive monitoring system is timely georeferenced data collection on CBB movement, coffee berry infestation, mortality by the fungus Beauveria bassiana, and coffee plant phenology via a mobile electronic data recording application. This electronic data collection system allows field records to be georeferenced through built-in global positioning systems, and is backed by a network of weather stations and records of farm management practices. Comprehensive monitoring of CBB and host plant dynamics is an essential part of an area-wide project in Hawaii to aggregate landscape-level data for research to improve management practices. Coffee agroecosystems in other parts of the world that experience highly variable environmental and socioeconomic factors will also benefit from implementing this protocol, in that it will drive the development of customized integrated pest management (IPM) to manage CBB populations.

  14. Nondestructive Methods for Monitoring Cell Removal During Rat Liver Decellularization.

    PubMed

    Geerts, Sharon; Ozer, Sinan; Jaramillo, Maria; Yarmush, Martin L; Uygun, Basak E

    2016-07-01

    Whole liver engineering holds the promise to create transplantable liver grafts that may serve as substitutes for donor organs, addressing the donor shortage in liver transplantation. While decellularization and recellularization of livers in animal models have been successfully achieved, scale up to human livers has been slow. There are a number of donor human livers that are discarded because they are not found suitable for transplantation, but are available for engineering liver grafts. These livers are rejected due to a variety of reasons, which in turn may affect the decellularization outcome. Hence, a one-size-fit-for all decellularization protocol may not result in scaffolds with consistent matrix quality, subsequently influencing downstream recellularization and transplantation outcomes. There is a need for a noninvasive monitoring method to evaluate the extent of cell removal, while ensuring preservation of matrix components during decellularization. In this study, we decellularized rat livers using a protocol previously established by our group, and we monitored decellularization through traditional destructive techniques, including evaluation of DNA, collagen, and glycosaminoglycan (GAG) content in decellularized scaffolds, as well as histology. In addition, we used computed tomography and perfusate analysis as alternative nondestructive decellularization monitoring methods. We found that DNA removal correlates well with the Hounsfield unit of the liver, and perfusate analysis revealed that significant amount of GAG is removed during perfusion with 0.1% sodium dodecyl sulfate. This allowed for optimization of our decellularization protocol leading to scaffolds that have significantly higher GAG content, while maintaining appropriate removal of cellular contents. The significance of this is the creation of a nondestructive monitoring strategy that can be used for optimization of decellularization protocols for individual human livers available for liver engineering.

  15. Nondestructive Methods for Monitoring Cell Removal During Rat Liver Decellularization

    PubMed Central

    Geerts, Sharon; Ozer, Sinan; Jaramillo, Maria; Yarmush, Martin L.

    2016-01-01

    Whole liver engineering holds the promise to create transplantable liver grafts that may serve as substitutes for donor organs, addressing the donor shortage in liver transplantation. While decellularization and recellularization of livers in animal models have been successfully achieved, scale up to human livers has been slow. There are a number of donor human livers that are discarded because they are not found suitable for transplantation, but are available for engineering liver grafts. These livers are rejected due to a variety of reasons, which in turn may affect the decellularization outcome. Hence, a one-size-fit-for all decellularization protocol may not result in scaffolds with consistent matrix quality, subsequently influencing downstream recellularization and transplantation outcomes. There is a need for a noninvasive monitoring method to evaluate the extent of cell removal, while ensuring preservation of matrix components during decellularization. In this study, we decellularized rat livers using a protocol previously established by our group, and we monitored decellularization through traditional destructive techniques, including evaluation of DNA, collagen, and glycosaminoglycan (GAG) content in decellularized scaffolds, as well as histology. In addition, we used computed tomography and perfusate analysis as alternative nondestructive decellularization monitoring methods. We found that DNA removal correlates well with the Hounsfield unit of the liver, and perfusate analysis revealed that significant amount of GAG is removed during perfusion with 0.1% sodium dodecyl sulfate. This allowed for optimization of our decellularization protocol leading to scaffolds that have significantly higher GAG content, while maintaining appropriate removal of cellular contents. The significance of this is the creation of a nondestructive monitoring strategy that can be used for optimization of decellularization protocols for individual human livers available for liver engineering. PMID:27169332

  16. Operational Implementation of a 2-Hour Prebreathe Protocol for International Space Station

    NASA Technical Reports Server (NTRS)

    Waligora, James M.; Conkin, J.; Foster, P. P.; Schneider, S.; Loftin, Karin C.; Gernhardt, Michael L.; Vann, R.

    2000-01-01

    Procedures, equipment, and analytical techniques were developed to implement the ground tested 2-hour protocol in-flight operations. The methods are: 1) The flight protocol incorporates additional safety margin over the ground tested protocol. This includes up to 20 min of additional time on enriched O2 during suit purge and pressure check, increased duration of extravehicular activity (EVA) preparation exercise during O2 prebreathing (up to 90 min vs; the tested 24 min), and reduced rates of depressurization. The ground test observations were combined with model projections of the conservative measures (using statistical models from Duke University and NASA JSQ to bound the risk of Type I and Type II decompression sickness (DCS). 2) An inflight exercise device using the in-flight ergometer and elastic tubes for upper body exercise was developed to replicate the dual cycle exercise in the ground trials. 3) A new in-flight breathing system was developed and man-tested. 4) A process to monitor inflight experience with the protocol, including the use of an in-suit Doppler bubble monitor when available, was developed. The results are: 1) The model projections of the conservative factors of the operational protocol were shown to reduce the risk of DCS to levels consistent with the observations of no DCS to date in the shuttle program. 2) Cross over trials of the dual cycle ergometer used in ground tests and the in-flight exercise system verified that02consumption and the % division of work between upper and lower body was not significantly different at the p= 0.05 level. 3) The in-flight breathing system was demonstrated to support work rates generating 75% O2(max) in 95 percentile subjects. 4) An in-flight monitoring plan with acceptance criteria was put in place for the 2-hour prebreathe protocol. And the conclusions are: The 2-hour protocol has been approved for flight, and all implementation efforts are in place to allow use of the protocol as early as flight ISS 7A, now scheduled in November of 2000.

  17. Twenty-Four-Hour Blood Pressure Monitoring to Predict and Assess Impact of Renal Denervation: The DENERHTN Study (Renal Denervation for Hypertension).

    PubMed

    Gosse, Philippe; Cremer, Antoine; Pereira, Helena; Bobrie, Guillaume; Chatellier, Gilles; Chamontin, Bernard; Courand, Pierre-Yves; Delsart, Pascal; Denolle, Thierry; Dourmap, Caroline; Ferrari, Emile; Girerd, Xavier; Michel Halimi, Jean; Herpin, Daniel; Lantelme, Pierre; Monge, Matthieu; Mounier-Vehier, Claire; Mourad, Jean-Jacques; Ormezzano, Olivier; Ribstein, Jean; Rossignol, Patrick; Sapoval, Marc; Vaïsse, Bernard; Zannad, Faiez; Azizi, Michel

    2017-03-01

    The DENERHTN trial (Renal Denervation for Hypertension) confirmed the blood pressure (BP) lowering efficacy of renal denervation added to a standardized stepped-care antihypertensive treatment for resistant hypertension at 6 months. We report here the effect of denervation on 24-hour BP and its variability and look for parameters that predicted the BP response. Patients with resistant hypertension were randomly assigned to denervation plus stepped-care treatment or treatment alone (control). Average and standard deviation of 24-hour, daytime, and nighttime BP and the smoothness index were calculated on recordings performed at randomization and 6 months. Responders were defined as a 6-month 24-hour systolic BP reduction ≥20 mm Hg. Analyses were performed on the per-protocol population. The significantly greater BP reduction in the denervation group was associated with a higher smoothness index ( P =0.02). Variability of 24-hour, daytime, and nighttime BP did not change significantly from baseline to 6 months in both groups. The number of responders was greater in the denervation (20/44, 44.5%) than in the control group (11/53, 20.8%; P =0.01). In the discriminant analysis, baseline average nighttime systolic BP and standard deviation were significant predictors of the systolic BP response in the denervation group only, allowing adequate responder classification of 70% of the patients. Our results show that denervation lowers ambulatory BP homogeneously over 24 hours in patients with resistant hypertension and suggest that nighttime systolic BP and variability are predictors of the BP response to denervation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01570777. © 2017 American Heart Association, Inc.

  18. Concurrent 3-D sonifications enable the head-up monitoring of two interrelated aircraft navigation instruments.

    PubMed

    Towers, John; Burgess-Limerick, Robin; Riek, Stephan

    2014-12-01

    The aim of this study was to enable the head-up monitoring of two interrelated aircraft navigation instruments by developing a 3-D auditory display that encodes this navigation information within two spatially discrete sonifications. Head-up monitoring of aircraft navigation information utilizing 3-D audio displays, particularly involving concurrently presented sonifications, requires additional research. A flight simulator's head-down waypoint bearing and course deviation instrument readouts were conveyed to participants via a 3-D auditory display. Both readouts were separately represented by a colocated pair of continuous sounds, one fixed and the other varying in pitch, which together encoded the instrument value's deviation from the norm. Each sound pair's position in the listening space indicated the left/right parameter of its instrument's readout. Participants' accuracy in navigating a predetermined flight plan was evaluated while performing a head-up task involving the detection of visual flares in the out-of-cockpit scene. The auditory display significantly improved aircraft heading and course deviation accuracy, head-up time, and flare detections. Head tracking did not improve performance by providing participants with the ability to orient potentially conflicting sounds, suggesting that the use of integrated localizing cues was successful. Conclusion: A supplementary 3-D auditory display enabled effective head-up monitoring of interrelated navigation information normally attended to through a head-down display. Pilots operating aircraft, such as helicopters and unmanned aerial vehicles, may benefit from a supplementary auditory display because they navigate in two dimensions while performing head-up, out-of-aircraft, visual tasks.

  19. The role of the Data and Safety Monitoring Board in a clinical trial: the CRISIS study.

    PubMed

    Holubkov, Richard; Casper, T Charles; Dean, J Michael; Anand, K J S; Zimmerman, Jerry; Meert, Kathleen L; Newth, Christopher J L; Berger, John; Harrison, Rick; Willson, Douglas F; Nicholson, Carol

    2013-05-01

    Randomized clinical trials are commonly overseen by a Data and Safety Monitoring Board comprised of experts in medicine, ethics, and biostatistics. Data and Safety Monitoring Board responsibilities include protocol approval, interim review of study enrollment, protocol compliance, safety, and efficacy data. Data and Safety Monitoring Board decisions can affect study design and conduct, as well as reported findings. Researchers must incorporate Data and Safety Monitoring Board oversight into the design, monitoring, and reporting of randomized trials. Case study, narrative review. The Data and Safety Monitoring Board's role during the comparative pediatric Critical Illness Stress-Induced Immune Suppression (CRISIS) Prevention Trial is described. The National Institutes of Health-appointed CRISIS Data and Safety Monitoring Board was charged with monitoring sample size adequacy and feasibility, safety with respect to adverse events and 28-day mortality, and efficacy with respect to the primary nosocomial infection/sepsis outcome. The Federal Drug Administration also requested Data and Safety Monitoring Board interim review before opening CRISIS to children below 1 yr of age. The first interim analysis found higher 28-day mortality in one treatment arm. The Data and Safety Monitoring Board maintained trial closure to younger children and requested a second interim data review 6 months later. At this second meeting, mortality was no longer of concern, whereas a weak efficacy trend of lower infection/sepsis rates in one study arm emerged. As over 40% of total patients had been enrolled, the Data and Safety Monitoring Board elected to examine conditional power and unmask treatment arm identities. On finding somewhat greater efficacy in the placebo arm, the Data and Safety Monitoring Board recommended stopping CRISIS due to futility. The design and operating procedures of a multicenter randomized trial must consider a pivotal Data and Safety Monitoring Board role. Maximum study design flexibility must be allowed, and investigators must be prepared for protocol modifications due to interim findings. The Data and Safety Monitoring Board must have sufficient clinical and statistical expertise to assess potential importance of interim treatment differences in the setting of multiple looks at accumulating data with numerous outcomes and subgroups.

  20. A mobile application to support collection and analytics of real-time critical care data.

    PubMed

    Vankipuram, Akshay; Vankipuram, Mithra; Ghaemmaghami, Vafa; Patel, Vimla L

    2017-11-01

    Data collection, in high intensity environments, poses several challenges including the ability to observe multiple streams of information. These problems are especially evident in critical care, where monitoring of the Advanced Trauma Life Support (ATLS) protocol provides an excellent opportunity to study the efficacy of applications that allow for the rapid capture of event information, providing theoretically-driven feedback using the data. Our goal was, (a) to design and implement a way to capture data on deviation from the standard practice based on the theoretical foundation of error classification from our past research, (b) to provide a means to meaningfully visualize the collected data, and (c) to provide a proof-of-concept for this implementation, using some understanding of user experience in clinical practice. We present the design and development of a web application designed to be used primarily on mobile devices and a summary data viewer to allow clinicians to, (a) track their activities, (b) provide real-time feedback of deviations from guidelines and protocols, and (c) provide summary feedback highlighting decisions made. We used a framework previously developed to classify activities in trauma as the theoretical foundation of the rules designed to do the same algorithmically, in our application. Attending physicians at a Level 1 trauma center used the application in the clinical setting and provided feedback for iterative development. Informal interviews and surveys were used to gain some deeper understanding of the user experience using this application in-situ. Activity visualizations were created highlighting decisions made during a trauma code as well as classification of tasks per the theoretical framework. The attendings reviewed the efficacy of the data visualizations as part of their interviews. We also conducted a proof-of-concept evaluation by way of usability questionnaire. Two attendings rated 4 out of the usability 6 categories highly (inter-rater reliability: R = 0.87; weighted kappa = 0.59). This could be attributed to the fact that they were able to fit the use of the application into their regular workflow during a trauma code relatively seamlessly. A deeper evaluation is required to answer explain this further. Our application can be used to capture and present data to provide an accurate reflection of work activities in real-time in complex critical care environments, without any significant interruptions to workflow. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.

    PubMed

    Vasak, Christoph; Strbac, Georg D; Huber, Christian D; Lettner, Stefan; Gahleitner, André; Zechner, Werner

    2015-02-01

    The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method. Overall, 60 implants were placed in 10 artificial edentulous mandibles according to the NobelGuide™ protocol. For merging the pre- and postoperative DICOM data sets, three different fusion methods (Triple Scan Technique, NobelGuide™ Validation software, and AMIRA® software [VSG - Visualization Sciences Group, Burlington, MA, USA] as reference) were applied. Discrepancies between the virtual and the actual implant positions were measured. The mean deviations measured with AMIRA® were 0.49 mm (implant shoulder), 0.69 mm (implant apex), and 1.98°mm (implant axis). The Triple Scan Technique as well as the NobelGuide™ Validation software revealed similar deviations compared with the reference method. A significant correlation between angular and apical deviations was seen (r = 0.53; p < .001). A greater implant diameter was associated with greater deviations (p = .03). The Triple Scan Technique as a system-independent validation procedure as well as the NobelGuide™ Validation software are in accordance with the AMIRA® software. The NobelGuide™ system showed similar or less spatial and angular deviations compared with others. © 2013 Wiley Periodicals, Inc.

  2. Sampling and analyses plan for tank 103 at the 219-S waste handling facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FOWLER, K.D.

    1999-06-23

    This document describes the sampling and analysis activities associated with taking a Resource Conservation and Recovery Act (RCRA) protocol sample of the waste from Tank 103 at the 21 9-S Waste Handling Facility treatment storage, andlor disposal (TSD) unit at the 2224 Laboratory complex. This sampling and analyses is required based on negotiations between the State of Washington Department of Ecology (Ecology) and the Department of Energy, Richland Operations, (RL) in letters concerning the TPA Change Form M-32-98-01. In a letter from George H. Sanders, RL to Moses N. Jaraysi, Ecology, dated January 28,1999, it was noted that ''Prior tomore » the Tank 103 waste inventory transfer, a RCRA protocol sample of the waste will be obtained and tested for the constituents contained on the Part A, Form 3 Permit Application for the 219-S Waste Handling Facility.'' In the April 2, 1999 letter, from Brenda L. Becher-Khaleel, Ecology to James, E. Rasmussen, RL, and William O. Adair, FDH, Ecology states that the purpose of these analyses is to provide information and justification for leaving Tank 103 in an isolated condition in the 2194 TSD unit until facility closure. The data may also be used at some future date in making decisions regarding closure methodology for Tank 103. Ecology also notes that As Low As Reasonably Achievable (ALARA) concerns may force deviations from some SW-846 protocol. Every effort will be made to accommodate requirements as specified. Deviations from SW-846 will be documented in accordance with HASQARD.« less

  3. Phenology monitoring protocol: Northeast Temperate Network

    USGS Publications Warehouse

    Tierney, Geri; Mitchell, Brian; Miller-Rushing, Abraham J.; Katz, Jonathan; Denny, Ellen; Brauer, Corinne; Donovan, Therese; Richardson, Andrew D.; Toomey, Michael; Kozlowski, Adam; Weltzin, Jake F.; Gerst, Kathy; Sharron, Ed; Sonnentag, Oliver; Dieffenbach, Fred

    2013-01-01

    historical parks and national historic sites in the northeastern US. This protocol was developed in collaboration with and relies upon the procedures and infrastructure of the USA National Phenology Network (USA-NPN), including Nature’s Notebook, USA-NPN’s online plant and animal phenology observation program (www.nn.usanpn.org). Organized in 2007, USA-NPN is a nation-wide partnership among federal agencies, schools and universities, citizen volunteers, and others to monitor and understand the influence of seasonal cycles on the nation’s biological resources. The overall goal of NETN’s phenology monitoring program is to determine trends in the phenology of key species in order to assist park managers with the detection and mitigation of the effects of climate change on park resources. An additional programmatic goal is to interest and educate park visitors and staff, as well as a cadre of volunteer monitors.

  4. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  5. Wound care clinical pathway: a conceptual model.

    PubMed

    Barr, J E; Cuzzell, J

    1996-08-01

    A clinical pathway is a written sequence of clinical processes or events that guides a patient with a defined problem toward an expected outcome. Clinical pathways are tools to assist with the cost-effective management of clinical outcomes related to specific problems or disease processes. The primary obstacles to developing clinical pathways for wound care are the chronic natures of some wounds and the many variables that can delay healing. The pathway introduced in this article was modeled upon the three phases of tissue repair: inflammatory, proliferative, and maturation. This physiology-based model allows clinicians to identify and monitor outcomes based on observable and measurable clinical parameters. The pathway design, which also includes educational and behavioral outcomes, allows the clinician to individualize the expected timeframe for outcome achievement based on individual patient criteria and expert judgement. Integral to the pathway are the "4P's" which help standardize the clinical processes by wound type: Protocols, Policies, Procedures, and Patient education tools. Four categories into which variances are categorized based on the cause of the deviation from the norm are patient, process/system, practitioner, and planning/discharge. Additional research is warranted to support the value of this clinical pathway in the clinical arena.

  6. Latest trends in the assessment and management of paediatric snoring and sleep apnoea.

    PubMed

    Sharma, S D; Kanona, H; Kumar, G; Kotecha, B

    2016-05-01

    To investigate the assessment and management of paediatric snoring and obstructive sleep apnoea in UK otolaryngology departments. A telephone questionnaire survey of UK otolaryngology departments was conducted over a 16-week period. The response rate was 61 per cent (85 out of 139 trusts). Use of pre-operative pulse oximetry was reported by 84 per cent of respondents, mainly to diagnose obstructive sleep apnoea (73 per cent) or stratify post-operative risk (46 per cent). Thirty-one per cent of respondents reported using post-operative pulse oximetry. Twenty-five per cent of respondents have a dedicated management protocol for paediatric obstructive sleep apnoea and snoring. Thirty-four per cent require prior clinical commissioning group approval before performing surgery. Fifty-eight per cent of respondents reported following up their obstructive sleep apnoea patients after surgery. The mean follow-up period (±standard deviation) was 6.8 ± 1.2 weeks. There is variation in the assessment and management of paediatric snoring and obstructive sleep apnoea across the UK, particularly in the use of pre- and post-operative pulse oximetry monitoring, and further guidelines regarding this are necessary.

  7. Soil quality monitoring: Examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...

  8. Soil quality monitoring: examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference, or in support of...

  9. Watching what widlife want and need

    Treesearch

    Natasha Vizcarra; Mary Rowland; Christina Vojta

    2016-01-01

    National forests and grasslands are home to a diverse array of wildlife. To keep tabs on the general viability and wellbeing of these inhabitants, land managers need practical, defensible monitoring protocols. Population monitoring is one method. Another is habitat monitoring, which provides critical information about the quantity and quality of key habitat attributes...

  10. 300 area TEDF NPDES Permit Compliance Monitoring Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, C.M.

    1995-09-05

    This document presents the 300 Area Treated Effluent Disposal Facility (TEDF) National Pollutant Discharge Elimination System (NPDES) Permit Compliance Monitoring Plan (MP). The MP describes how ongoing monitoring of the TEDF effluent stream for compliance with the NPDES permit will occur. The MP also includes Quality Assurance protocols to be followed.

  11. Adolescent pedometer protocols: examining reactivity, tampering and participants' perceptions.

    PubMed

    Scott, Joseph John; Morgan, Philip James; Plotnikoff, Ronald Cyril; Trost, Stewart Graeme; Lubans, David Revalds

    2014-01-01

    The aim of this study was to investigate adolescents' potential reactivity and tampering while wearing pedometers by comparing different monitoring protocols to accelerometer output. The sample included adolescents (N = 123, age range = 14-15 years) from three secondary schools in New South Wales, Australia. Schools were randomised to one of the three pedometer monitoring protocols: (i) daily sealed (DS) pedometer group, (ii) unsealed (US) pedometer group or (iii) weekly sealed (WS) pedometer group. Participants wore pedometers (Yamax Digi-Walker CW700, Yamax Corporation, Kumamoto City, Japan) and accelerometers (Actigraph GT3X+, Pensacola, USA) simultaneously for seven days. Repeated measures analysis of variance was used to examine potential reactivity. Bivariate correlations between step counts and accelerometer output were calculated to explore potential tampering. The correlation between accelerometer output and pedometer steps/day was strongest among participants in the WS group (r = 0.82, P ≤ 0.001), compared to the US (r = 0.63, P ≤ 0.001) and DS (r = 0.16, P = 0.324) groups. The DS (P ≤ 0.001) and US (P = 0.003), but not the WS (P = 0.891), groups showed evidence of reactivity. The results suggest that reactivity and tampering does occur in adolescents and contrary to existing research, pedometer monitoring protocols may influence participant behaviour.

  12. Monitoring concept for structural integration of PZT-fiber arrays in metal sheets: a numerical and experimental study

    NASA Astrophysics Data System (ADS)

    Drossel, Welf-Guntram; Schubert, Andreas; Putz, Matthias; Koriath, Hans-Joachim; Wittstock, Volker; Hensel, Sebastian; Pierer, Alexander; Müller, Benedikt; Schmidt, Marek

    2018-01-01

    The technique joining by forming allows the structural integration of piezoceramic fibers into locally microstructured metal sheets without any elastic interlayers. A high-volume production of the joining partners causes in statistical deviations from the nominal dimensions. A numerical simulation on geometric process sensitivity shows that the deviations have a high significant influence on the resulting fiber stresses after the joining by forming operation and demonstrate the necessity of a monitoring concept. On this basis, the electromechanical behavior of piezoceramic array transducers is investigated experimentally before, during and after the joining process. The piezoceramic array transducer consists of an arrangement of five electrical interconnected piezoceramic fibers. The findings show that the impedance spectrum depends on the fiber stresses and can be used for in-process monitoring during the joining process. Based on the impedance values the preload state of the interconnected piezoceramic fibers can be specifically controlled and a fiber overload.

  13. A Data Filter for Identifying Steady-State Operating Points in Engine Flight Data for Condition Monitoring Applications

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Litt, Jonathan S.

    2010-01-01

    This paper presents an algorithm that automatically identifies and extracts steady-state engine operating points from engine flight data. It calculates the mean and standard deviation of select parameters contained in the incoming flight data stream. If the standard deviation of the data falls below defined constraints, the engine is assumed to be at a steady-state operating point, and the mean measurement data at that point are archived for subsequent condition monitoring purposes. The fundamental design of the steady-state data filter is completely generic and applicable for any dynamic system. Additional domain-specific logic constraints are applied to reduce data outliers and variance within the collected steady-state data. The filter is designed for on-line real-time processing of streaming data as opposed to post-processing of the data in batch mode. Results of applying the steady-state data filter to recorded helicopter engine flight data are shown, demonstrating its utility for engine condition monitoring applications.

  14. Global Health Diplomacy, Monitoring & Evaluation, and the Importance of Quality Assurance & Control: Findings from NIMH Project Accept (HPTN 043): A Phase III Randomized Controlled Trial of Community Mobilization, Mobile Testing, Same-Day Results, and Post-Test Support for HIV in Sub-Saharan Africa and Thailand.

    PubMed

    Kevany, Sebastian; Khumalo-Sakutukwa, Gertrude; Singh, Basant; Chingono, Alfred; Morin, Stephen

    2016-01-01

    Provision and scale-up of high quality, evidence-based services is essential for successful international HIV prevention interventions in order to generate and maintain intervention uptake, study integrity and participant trust, from both health service delivery and diplomatic perspectives. We developed quality assurance (QAC) procedures to evaluate staff fidelity to a cluster-randomized trial of the NIMH Project Accept (HPTN 043) assessing the effectiveness of a community-based voluntary counseling and testing strategy. The intervention was comprised of three components-Mobile Voluntary Counseling and Testing (MVCT), Community Mobilization (CM) and Post-Test Support Services (PTSS). QAC procedures were based on standardized criteria, and were designed to assess both provider skills and adherence to the intervention protocol. Supervisors observed a random sample of 5% to 10% of sessions each month and evaluated staff against multiple criteria on scales of 1-5. A score of 5 indicated 100% adherence, 4 indicated 95% adherence, and 3 indicated 90% adherence. Scores below 3 were considered unsatisfactory, and protocol deviations were discussed with the respective staff. During the first year of the intervention, the mean scores of MVCT and CM staff across the 5 study sites were 4 (95% adherence) or greater and continued to improve over time. Mean QAC scores for the PTSS component were lower and displayed greater fluctuations. Challenges to PTSS staff were identified as coping with the wide range of activities in the PTSS component and the novelty of the PTSS process. QAC fluctuations for PTSS were also associated with new staff hires or changes in staff responsibilities. Through constant staff monitoring and support, by Year 2, QAC scores for PTSS activities had reached those of MVCT and CM. The implementation of a large-sale, evidence based HIV intervention requires extensive QAC to ensure implementation effectiveness. Ongoing appraisal of study staff across sites ensures consistent and high quality delivery of all intervention components, in keeping with the goals of the study protocol, while also providing a forum for corrective feedback, additional supervision and retraining of staff. QAC ensures staff fidelity to study procedures and is critical to the successful delivery of multi-site HIV prevention interventions, as well as the delivery of services scaled up in programmatic situations.

  15. The impact of posture and prolonged cyclic compressive loading on vertebral joint mechanics.

    PubMed

    Gooyers, Chad E; McMillan, Robert D; Howarth, Samuel J; Callaghan, Jack P

    2012-08-01

    An in vitro biomechanics investigation exposing porcine functional spinal units (FSUs) to submaximal cyclic or static compressive forces while in a flexed, neutral, or extended posture. To investigate the combined effect of cyclically applied compressive force (e.g., vibration) and postural deviation on intervertebral joint mechanics. Independently, prolonged vibration exposure and non-neutral postures are known risk factors for development of low back pain and injury. However, there is limited basic scientific evidence to explain how the risk of low back injury from vibration exposure is modified by other mechanical factors. This work examined the influence of static postural deviation on vertebral joint height loss and compressive stiffness under cyclically applied compressive force. Forty-eight FSUs, consisting of 2 adjacent vertebrae, ligaments, and the intervening intervertebral disc were included in the study. Each specimen was randomized to 1 of 3 experimental posture conditions (neutral, flexed, or extended) and assigned to 1 of 2 loading protocols, consisting of (1) cyclic (1500 ± 1200 N applied at 5 Hz using a sinusoidal waveform, resulting in 0.2 g rms acceleration) or (2) 1500 N of static compressive force. RESULTS.: As expected, FSU height loss followed a typical first-order response in both the static and cyclic loading protocols, with the majority (~50%) of the loss occurring in the first 20 minutes of testing. A significant interaction between posture and loading protocol (P < 0.001) was noted in the magnitude of FSU height loss. Subsequent analysis of simple effects revealed significant differences between cyclic and static loading protocols in both a neutral (P = 0.016) and a flexed posture (P < 0.0001). No significant differences (P = 0.320) were noted between pre/postmeasurements of FSU compressive stiffness. Posture is an important mechanical factor to consider when assessing the risk of injury from cyclic loading to the lumbar spine.

  16. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    PubMed Central

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  17. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis.

    PubMed

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-12-16

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world.

  18. I-MAC: an incorporation MAC for wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Zhao, Jumin; Li, Yikun; Li, Dengao; Lin, Xiaojie

    2017-11-01

    This paper proposes an innovative MAC protocol called I-MAC. Protocol for wireless sensor networks, which combines the advantages of collision tolerance and collision cancellation. The protocol increases the number of antenna in wireless sensor nodes. The purpose is to monitor the occurrence of packet collisions by increasing the number of antenna in real time. The built-in identity structure is used in the frame structure in order to help the sending node to identify the location of the receiving node after a data packet collision is detected. Packets can be recovered from where the conflict occurred. In this way, we can monitor the conflict for a fixed period of time. It can improve the channel utilisation through changing the transmission probability of collision nodes and solve the problem of hidden terminal through collision feedback mechanism. We have evaluated our protocol. Our results show that the throughput of I-MAC is 5 percentage points higher than that of carrier sense multiple access/collision notification. The network utilisation of I-MAC is more than 92%.

  19. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    PubMed

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in need of such a program.

  20. Establishing treatment protocols for clinical mastitis.

    PubMed

    Roberson, Jerry R

    2003-03-01

    Each farm has a unique mix of mastitis pathogens and management procedures that have evolved over time. The herd veterinarian should work with the manager/owner to systematically develop treatment protocols that meet the needs and management of the farm. To establish a mastitis treatment protocol, it is necessary to develop a system to routinely identify clinical mastitis cases, develop a herd-specific severity level assessment system, manage the clinical mastitis cases based on severity level and culture result (when available), avoid antibiotic residues, and monitor the success of the system and alter the protocol as necessary.

  1. Action Monitoring Cortical Activity Coupled to Submovements

    PubMed Central

    Sobolewski, Aleksander

    2017-01-01

    Numerous studies have examined neural correlates of the human brain’s action-monitoring system during experimentally segmented tasks. However, it remains unknown how such a system operates during continuous motor output when no experimental time marker is available (such as button presses or stimulus onset). We set out to investigate the electrophysiological correlates of action monitoring when hand position has to be repeatedly monitored and corrected. For this, we recorded high-density electroencephalography (EEG) during a visuomotor tracking task during which participants had to follow a target with the mouse cursor along a visible trajectory. By decomposing hand kinematics into naturally occurring periodic submovements, we found an event-related potential (ERP) time-locked to these submovements and localized in a sensorimotor cortical network comprising the supplementary motor area (SMA) and the precentral gyrus. Critically, the amplitude of the ERP correlated with the deviation of the cursor, 110 ms before the submovement. Control analyses showed that this correlation was truly due to the cursor deviation and not to differences in submovement kinematics or to the visual content of the task. The ERP closely resembled those found in response to mismatch events in typical cognitive neuroscience experiments. Our results demonstrate the existence of a cortical process in the SMA, evaluating hand position in synchrony with submovements. These findings suggest a functional role of submovements in a sensorimotor loop of periodic monitoring and correction and generalize previous results from the field of action monitoring to cases where action has to be repeatedly monitored. PMID:29071301

  2. Monitoring of brain oxygen saturation (INVOS) in a protocol to direct blood transfusions during cardiac surgery: a prospective randomized clinical trial.

    PubMed

    Vretzakis, George; Georgopoulou, Stavroula; Stamoulis, Konstantinos; Tassoudis, Vassilios; Mikroulis, Dimitrios; Giannoukas, Athanasios; Tsilimingas, Nikolaos; Karanikolas, Menelaos

    2013-06-07

    Blood transfusions are common in cardiac surgery, but have been associated with increased morbidity and long-term mortality. Efforts to reduce blood product use during cardiac surgery include fluid restriction to minimize hemodilution, and protocols to guide transfusion decisions. INVOS is a modality that monitors brain tissue oxygen saturation, and could be useful in guiding decisions to transfuse. However, the role of INVOS (brain tissue oxygen saturation) as part of an algorithm to direct blood transfusions during cardiac surgery has not been evaluated. This study was conducted to investigate the value of INVOS as part of a protocol for blood transfusions during cardiac surgery. Prospective, randomized, blinded clinical trial, on 150 (75 per group) elective cardiac surgery patients. The study was approved by the Institution Ethics committee and all patients gave written informed consent. Data were initially analyzed based on "intention to treat", but subsequently were also analyzed "per protocol". When protocol was strictly followed ("per protocol analysis"), compared to the control group, significantly fewer patients monitored with INVOS received any blood transfusions (46 of 70 patients in INVOS group vs. 55 of 67 patients in the control group, p = 0.029). Similarly, patients monitored with INVOS received significantly fewer units of red blood cell transfusions intraoperatively (0.20 ± 0.50 vs. 0.52 ± 0.88, p = 0.008) and overall during hospital stay (1.31 ± 1.20 vs. 1.82 ± 1.46, p = 0.024). When data from all patients (including patient with protocol violation) were analyzed together ("intention to treat analysis"), the observed reduction of blood transfusions in the INVOS group was still significant (51 of 75 patients transfused in the INVOS group vs. 63 of 75 patients transfused in the control group, p = 0.021), but the overall number of units transfused per patient did not differ significantly between the groups (1.55 ± 1.97 vs. 1.84 ± 1.41, p = 0.288). Our data suggest that INVOS could be a useful tool as part of an algorithm to guide decisions for blood transfusion in cardiac surgery. Additional data from rigorous, well designed studies are needed to further evaluate the role of INVOS in guiding blood transfusions in cardiac surgery, and circumvent the limitations of this study.

  3. Identifying Effective and Sustainable Measures for Community-Based Environmental Monitoring

    NASA Astrophysics Data System (ADS)

    McKay, Ariana J.; Johnson, Chris J.

    2017-09-01

    Resource development projects typically result in monitoring programs that fail to fully consider the values and participation of surrounding communities. Also, monitoring protocols for single environmental values can be insufficient for addressing the cumulative impacts of resource development. Community-based environmental monitoring (CBEM) has emerged as a way to meaningfully include local citizens in the decision-making process and assessment of the development of natural resources. Our research explored how to develop effective and sustainable CBEM. Interviews were conducted with staff from 15 CBEM programs established across Canada to identify criteria of what constitutes effective CBEM. Results demonstrate that CBEM offers an effective, locally adapted, and culturally applicable approach to facilitate community participation in natural resource management and to track environmental change. Benefits of CBEM include: locally relevant monitoring protocols, inclusion of cumulative impacts, better informed decision-making, and increased awareness and collaboration amongst community, governments, and proponents. Challenges associated with CBEM are cost, capacity, longevity, distribution of results, and establishing credibility. This research validates the use of CBEM for improving resource management.

  4. How to construct an optimal interim report: What the data monitoring committee does and doesn't need to know.

    PubMed

    Neaton, James D; Grund, Birgit; Wentworth, Deborah

    2018-03-01

    Data monitoring committees for randomized clinical trials have the responsibility of safeguarding interests of trial participants. To do so, the data monitoring committee must receive reports on safety and efficacy to assess risk/benefit and on trial conduct to ensure that the study can achieve its goals. This article outlines the key components of reports to the data monitoring committee and the important role of the unblinded statistician in preparing those reports. Most data monitoring committee meetings include open and closed sessions. For each session, there is a report of interim results. The open session is attended by the sponsor and lead investigators, including the statistician(s) responsible for the trial design. These investigators are blinded to the interim treatment comparisons. The closed session is attended by the data monitoring committee members and by the statistician(s) who prepared the closed report. These individuals are unblinded to interim treatment comparisons and therefore are not involved in study design changes. The optimal content of data monitoring committee reports and qualifications of the unblinded statistician(s) are discussed. Open reports should include responses to data monitoring committee recommendations, a synopsis of the protocol, a review of the protocol history and amendments, and information on enrollment, baseline characteristics, completeness of follow-up, and data quality. The open report is also a vehicle through which the sponsor and investigators should inform the data monitoring committee of relevant external information. Data in the open report are pooled over the treatment groups. The open report should not include data summaries by treatment group. The closed report should include a written summary with references to key tables and figures and methods used to prepare them. Tables and figures should summarize baseline characteristics, follow-up completeness, treatment adherence, and major safety and efficacy outcomes by treatment group. Text summaries should accompany the tables and figures. The data monitoring committee monitoring history (e.g. treatment differences at previous meetings) should be summarized. The unblinded statistician preparing the closed report should be familiar with the protocol and data collection plan and be capable of customizing the report to the current stage of the trial. This includes anticipating questions that may arise during the data monitoring committee review and pro-actively including data summaries to address these questions. There is considerable variation in the quality of open and closed data monitoring committee reports. Open and closed data monitoring committee reports should be concise, up to date, and informative. To achieve this, unblinded statisticians responsible for preparing closed data monitoring committee reports should be familiar with the statistical methods, the trial protocol, and the data collection plan. They should be capable of anticipating questions from the data monitoring committee and responding to requests for additional analyses.

  5. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...

  6. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  7. What Do We Really Know About the Safety of Tai Chi?: A Systematic Review of Adverse Event Reports in Randomized Trials

    PubMed Central

    Wayne, Peter M.; Berkowitz, Danielle L.; Litrownik, Daniel E.; Buring, Julie E.; Yeh, Gloria Y.

    2014-01-01

    Objective Systematically review frequency and quality of adverse event (AE) reports in randomized clinical trials (RCTs) of Tai Chi (TC). Data Sources Electronic searches of PubMed/MEDLINE and additional databases from inception through March 2013 of English-language RCTs. Search terms were tai chi, taiji, tai chi chuan. Data were independently extracted by two investigators. Study Selection We included all available randomized controlled trials (RCTs) that were published in English and used Tai Chi as an intervention. Inclusion and exclusion of studies were reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Data Extraction Eligible RCTs were categorized with respect to AE reporting: 1) No mention of protocols for monitoring AEs or reports of AEs; 2) Reports of AEs either with or without explicit protocols for monitoring AEs. Data Synthesis 153 eligible RCTs were identified, most targeting older adults. Only 50 eligible trials (33%) included reporting of AEs, and of these, only 18 trials (12% overall) also reported an explicit AE monitoring protocol. Protocols varied with respect to rigor of systematic monitoring in both Tai Chi and comparison groups. Reported AEs were typically minor and expected, and primarily musculoskeletal related (e.g., knee and back pain); no intervention-related serious AEs were reported. Conclusions Tai Chi is unlikely to result in serious adverse events, but may be associated with minor musculoskeletal aches and pains. However, poor and inconsistent reporting of AEs greatly limits the conclusions that can be drawn regarding the safety of Tai Chi. PMID:24878398

  8. Generalized linear models and point count data: statistical considerations for the design and analysis of monitoring studies

    Treesearch

    Nathaniel E. Seavy; Suhel Quader; John D. Alexander; C. John Ralph

    2005-01-01

    The success of avian monitoring programs to effectively guide management decisions requires that studies be efficiently designed and data be properly analyzed. A complicating factor is that point count surveys often generate data with non-normal distributional properties. In this paper we review methods of dealing with deviations from normal assumptions, and we focus...

  9. A watershed-scale monitoring protocol for bull trout

    Treesearch

    Dan Isaak; Bruce Rieman; Dona Horan

    2009-01-01

    Bull trout is a threatened species native to the Pacific Northwest that has been selected as Management Indicator Species on several national forests. Scientifically defensible procedures for monitoring bull trout populations are necessary that can be applied to the extensive and remote lands managed by the U.S. Forest Service. Distributional monitoring focuses...

  10. Noninvasive and cost-effective trapping method for monitoring sensitive mammal populations

    Treesearch

    Stephanie E. Trapp; Elizabeth A. Flaherty

    2017-01-01

    Noninvasive sampling methods provide a means to monitor endangered, threatened, or sensitive species or populations while increasing the efficacy of personnel effort and time. We developed a monitoring protocol that utilizes single-capture hair snares and analysis of morphological features of hair for evaluating populations. During 2015, we used the West Virginia...

  11. Keeping Scores: Audited Self-Monitoring of High-Stakes Testing Environments

    ERIC Educational Resources Information Center

    Padilla, Raymond; Richards, Michael

    2006-01-01

    To address a public relations problem faced by a large urban public school district in Texas, we conducted action research that resulted in an audited self-monitoring system for high-stakes testing environments. The system monitors violations of testing protocols while identifying and disseminating best practices to improve the education of…

  12. Sample size allocation for food item radiation monitoring and safety inspection.

    PubMed

    Seto, Mayumi; Uriu, Koichiro

    2015-03-01

    The objective of this study is to identify a procedure for determining sample size allocation for food radiation inspections of more than one food item to minimize the potential risk to consumers of internal radiation exposure. We consider a simplified case of food radiation monitoring and safety inspection in which a risk manager is required to monitor two food items, milk and spinach, in a contaminated area. Three protocols for food radiation monitoring with different sample size allocations were assessed by simulating random sampling and inspections of milk and spinach in a conceptual monitoring site. Distributions of (131)I and radiocesium concentrations were determined in reference to (131)I and radiocesium concentrations detected in Fukushima prefecture, Japan, for March and April 2011. The results of the simulations suggested that a protocol that allocates sample size to milk and spinach based on the estimation of (131)I and radiocesium concentrations using the apparent decay rate constants sequentially calculated from past monitoring data can most effectively minimize the potential risks of internal radiation exposure. © 2014 Society for Risk Analysis.

  13. Validation protocols for blood pressure-measuring devices: status quo and development needs.

    PubMed

    Beime, Beate; Deutsch, Cornelia; Gomez, Timothy; Zwingers, Thomas; Mengden, Thomas; Bramlage, Peter

    2016-02-01

    Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy of blood pressure monitoring devices have been developed, including protocols by the Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League (Prüfsiegelprotokoll), and the International Protocol of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. In the past, most of the protocols have been reviewed and modified because of experiences gained during the validation studies carried out. However, each shows distinct differences, that is number and characteristics of patients required, blood pressure ranges, and the length of the validation procedure, which may result in unique advantages and/or limitations associated with their use. The continued standardization and evolution of these guidelines is essential to ensure the efficacy of blood pressure-measuring devices marketed for clinical and home use. Here, we aimed to compare four currently used validation protocols and to initiate a discussion on potential future improvements.

  14. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Apparent diffusion coefficient is highly reproducible on preclinical imaging systems: Evidence from a seven-center multivendor study.

    PubMed

    Doblas, Sabrina; Almeida, Gilberto S; Blé, François-Xavier; Garteiser, Philippe; Hoff, Benjamin A; McIntyre, Dominick J O; Wachsmuth, Lydia; Chenevert, Thomas L; Faber, Cornelius; Griffiths, John R; Jacobs, Andreas H; Morris, David M; O'Connor, James P B; Robinson, Simon P; Van Beers, Bernard E; Waterton, John C

    2015-12-01

    To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed. © 2015 Wiley Periodicals, Inc.

  16. INDUCTIVE SYSTEM HEALTH MONITORING WITH STATISTICAL METRICS

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    2005-01-01

    Model-based reasoning is a powerful method for performing system monitoring and diagnosis. Building models for model-based reasoning is often a difficult and time consuming process. The Inductive Monitoring System (IMS) software was developed to provide a technique to automatically produce health monitoring knowledge bases for systems that are either difficult to model (simulate) with a computer or which require computer models that are too complex to use for real time monitoring. IMS processes nominal data sets collected either directly from the system or from simulations to build a knowledge base that can be used to detect anomalous behavior in the system. Machine learning and data mining techniques are used to characterize typical system behavior by extracting general classes of nominal data from archived data sets. In particular, a clustering algorithm forms groups of nominal values for sets of related parameters. This establishes constraints on those parameter values that should hold during nominal operation. During monitoring, IMS provides a statistically weighted measure of the deviation of current system behavior from the established normal baseline. If the deviation increases beyond the expected level, an anomaly is suspected, prompting further investigation by an operator or automated system. IMS has shown potential to be an effective, low cost technique to produce system monitoring capability for a variety of applications. We describe the training and system health monitoring techniques of IMS. We also present the application of IMS to a data set from the Space Shuttle Columbia STS-107 flight. IMS was able to detect an anomaly in the launch telemetry shortly after a foam impact damaged Columbia's thermal protection system.

  17. Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: a prospective radiological study.

    PubMed

    Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner

    2011-10-01

    This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were within the safety margins recommended by the planning software. © 2011 John Wiley & Sons A/S.

  18. Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements.

    PubMed

    Lindemann, Ulrich; Zijlstra, Wiebren; Aminian, Kamiar; Chastin, Sebastien F M; de Bruin, Eling D; Helbostad, Jorunn L; Bussmann, Johannes B J

    2014-01-10

    Physical activity is an important determinant of health and well-being in older persons and contributes to their social participation and quality of life. Hence, assessment tools are needed to study this physical activity in free-living conditions. Wearable motion sensing technology is used to assess physical activity. However, there is a lack of harmonisation of validation protocols and applied statistics, which make it hard to compare available and future studies. Therefore, the aim of this paper is to formulate recommendations for assessing the validity of sensor-based activity monitoring in older persons with focus on the measurement of body postures and movements. Validation studies of body-worn devices providing parameters on body postures and movements were identified and summarized and an extensive inter-active process between authors resulted in recommendations about: information on the assessed persons, the technical system, and the analysis of relevant parameters of physical activity, based on a standardized and semi-structured protocol. The recommended protocols can be regarded as a first attempt to standardize validity studies in the area of monitoring physical activity.

  19. Implementation of ICP-MS protocols for uranium urinary measurements in worker monitoring.

    PubMed

    Baglan, N; Cossonnet, C; Trompier, F; Ritt, J; Bérard, P

    1999-10-01

    The uranium concentration in human urine spiked with natural uranium and rat urine containing metabolized depleted uranium was determined by ICP-MS. The use of ICP-MS was investigated without any chemical treatment or after the different stages of a purification protocol currently carried out for routine monitoring. In the case of spiked urine, the measured uranium concentrations were consistent with those certified by an intercomparison network in radiotoxicological analysis (PROCORAD) and with those obtained by alpha spectrometry in the case of the urine containing metabolized uranium. The quantitative information which could be obtained in the different protocols investigated shows the extent to which ICP-MS provides greater flexibility for setting up appropriate monitoring approaches in radiation protection routines and accidental situations. This is due to the combination of high sensitivity and the accuracy with which traces of uranium in urine can be determined in a shorter time period. Moreover, it has been shown that ICP-MS measurement can be used to quantify the 235U isotope, which is useful for characterizing the nature of the uranium compound, but difficult to perform using alpha spectrometry.

  20. Linking community-based monitoring to water policy: Perceptions of citizen scientists.

    PubMed

    Carlson, Tyler; Cohen, Alice

    2018-05-05

    This paper examines the relationships between Community-Based Water Monitoring (CBM) and government-led water initiatives. Drawing on a cross-Canada survey of over one hundred organizations, we explore the reasons why communities undertake CBM, the monitoring protocols they follow, and the extent to which CBM program members feel their findings are incorporated into formal (i.e., government-led) decision-making processes. Our results indicate that despite following standardized and credible monitoring protocols, fewer than half of CBM organizations report that their data is being used to inform water policy at any level of government. Moreover, respondents report higher rates of cooperation and data-sharing between CBM organizations themselves than between CBM organizations and their respective governments. These findings are significant, because many governments continue to express support for CBM. We explore the barriers between CBM data collection and government policy, and suggest that structural barriers include lack of multi-year funding, inconsistent protocols, and poor communication. More broadly, we argue that the distinction between formal and informal programming is unclear, and that addressing known CBM challenges will rely on a change in perception: CBM cannot simply be a less expensive alternative to government-driven data collection. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. An Energy-Efficient MAC Protocol for Medical Emergency Monitoring Body Sensor Networks

    PubMed Central

    Zhang, Chongqing; Wang, Yinglong; Liang, Yongquan; Shu, Minglei; Chen, Changfang

    2016-01-01

    Medical emergency monitoring body sensor networks (BSNs) monitor the occurrence of medical emergencies and are helpful for the daily care of the elderly and chronically ill people. Such BSNs are characterized by rare traffic when there is no emergency occurring, high real-time and reliable requirements of emergency data and demand for a fast wake-up mechanism for waking up all nodes when an emergency happens. A beacon-enabled MAC protocol is specially designed to meet the demands of medical emergency monitoring BSNs. The rarity of traffic is exploited to improve energy efficiency. By adopting a long superframe structure to avoid unnecessary beacons and allocating most of the superframe to be inactive periods, the duty cycle is reduced to an extremely low level to save energy. Short active time slots are interposed into the superframe and shared by all of the nodes to deliver the emergency data in a low-delay and reliable way to meet the real-time and reliable requirements. The interposition slots can also be used by the coordinator to broadcast network demands to wake-up all nodes in a low-delay and energy-efficient way. Experiments display that the proposed MAC protocol works well in BSNs with low emergency data traffic. PMID:26999145

  2. Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method.

    PubMed

    Prest, E I; Hammes, F; Kötzsch, S; van Loosdrecht, M C M; Vrouwenvelder, J S

    2013-12-01

    Flow cytometry (FCM) is a rapid, cultivation-independent tool to assess and evaluate bacteriological quality and biological stability of water. Here we demonstrate that a stringent, reproducible staining protocol combined with fixed FCM operational and gating settings is essential for reliable quantification of bacteria and detection of changes in aquatic bacterial communities. Triplicate measurements of diverse water samples with this protocol typically showed relative standard deviation values and 95% confidence interval values below 2.5% on all the main FCM parameters. We propose a straightforward and instrument-independent method for the characterization of water samples based on the combination of bacterial cell concentration and fluorescence distribution. Analysis of the fluorescence distribution (or so-called fluorescence fingerprint) was accomplished firstly through a direct comparison of the raw FCM data and subsequently simplified by quantifying the percentage of large and brightly fluorescent high nucleic acid (HNA) content bacteria in each sample. Our approach enables fast differentiation of dissimilar bacterial communities (less than 15 min from sampling to final result), and allows accurate detection of even small changes in aquatic environments (detection above 3% change). Demonstrative studies on (a) indigenous bacterial growth in water, (b) contamination of drinking water with wastewater, (c) household drinking water stagnation and (d) mixing of two drinking water types, univocally showed that this FCM approach enables detection and quantification of relevant bacterial water quality changes with high sensitivity. This approach has the potential to be used as a new tool for application in the drinking water field, e.g. for rapid screening of the microbial water quality and stability during water treatment and distribution in networks and premise plumbing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Evaluation of digital radiography practice using exposure index tracking

    PubMed Central

    Zhou, Yifang; Allahverdian, Janet; Nute, Jessica L.; Lee, Christina

    2016-01-01

    Some digital radiography (DR) detectors and software allow for remote download of exam statistics, including image reject status, body part, projection, and exposure index (EI). The ability to have automated data collection from multiple DR units is conducive to a quality control (QC) program monitoring institutional radiographic exposures. We have implemented such a QC program with the goal to identify outliers in machine radiation output and opportunities for improvement in radiation dose levels. We studied the QC records of four digital detectors in greater detail on a monthly basis for one year. Although individual patient entrance skin exposure varied, the radiation dose levels to the detectors were made to be consistent via phototimer recalibration. The exposure data stored on each digital detector were periodically downloaded in a spreadsheet format for analysis. EI median and standard deviation were calculated for each protocol (by body part) and EI histograms were created for torso protocols. When histograms of EI values for different units were compared, we observed differences up to 400 in average EI (representing 60% difference in radiation levels to the detector) between units nominally calibrated to the same EI. We identified distinct components of the EI distributions, which in some cases, had mean EI values 300 apart. Peaks were observed at the current calibrated EI, a previously calibrated EI, and an EI representing computed radiography (CR) techniques. Our findings in this ongoing project have allowed us to make useful interventions, from emphasizing the use of phototimers instead of institutional memory of manual techniques to improvements in our phototimer calibration. We believe that this QC program can be implemented at other sites and can reveal problems with radiation levels in the aggregate that are difficult to identify on a case‐by‐case basis. PACS number(s): 87.59.bf PMID:27929507

  4. Describing temporal variation in reticuloruminal pH using continuous monitoring data.

    PubMed

    Denwood, M J; Kleen, J L; Jensen, D B; Jonsson, N N

    2018-01-01

    Reticuloruminal pH has been linked to subclinical disease in dairy cattle, leading to considerable interest in identifying pH observations below a given threshold. The relatively recent availability of continuously monitored data from pH boluses gives new opportunities for characterizing the normal patterns of pH over time and distinguishing these from abnormal patterns using more sensitive and specific methods than simple thresholds. We fitted a series of statistical models to continuously monitored data from 93 animals on 13 farms to characterize normal variation within and between animals. We used a subset of the data to relate deviations from the normal pattern to the productivity of 24 dairy cows from a single herd. Our findings show substantial variation in pH characteristics between animals, although animals within the same farm tended to show more consistent patterns. There was strong evidence for a predictable diurnal variation in all animals, and up to 70% of the observed variation in pH could be explained using a simple statistical model. For the 24 animals with available production information, there was also a strong association between productivity (as measured by both milk yield and dry matter intake) and deviations from the expected diurnal pattern of pH 2 d before the productivity observation. In contrast, there was no association between productivity and the occurrence of observations below a threshold pH. We conclude that statistical models can be used to account for a substantial proportion of the observed variability in pH and that future work with continuously monitored pH data should focus on deviations from a predictable pattern rather than the frequency of observations below an arbitrary pH threshold. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.

    PubMed

    Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C

    2016-05-01

    The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.

  6. The ICT monitoring system of the ASTRI SST-2M prototype proposed for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, F.; Bruno, P.; Tacchini, A.; Conforti, V.; Fioretti, V.; Tanci, C.; Grillo, A.; Leto, G.; Malaguti, G.; Trifoglio, M.

    2016-08-01

    In the framework of the international Cherenkov Telescope Array (CTA) observatory, the Italian National Institute for Astrophysics (INAF) has developed a dual mirror, small sized, telescope prototype (ASTRI SST-2M), installed in Italy at the INAF observing station located at Serra La Nave, Mt. Etna. The ASTRI SST-2M prototype is the basis of the ASTRI telescopes that will form the mini-array proposed to be installed at the CTA southern site during its preproduction phase. This contribution presents the solutions implemented to realize the monitoring system for the Information and Communication Technology (ICT) infrastructure of the ASTRI SST-2M prototype. The ASTRI ICT monitoring system has been implemented by integrating traditional tools used in computer centers, with specific custom tools which interface via Open Platform Communication Unified Architecture (OPC UA) to the Alma Common Software (ACS) that is used to operate the ASTRI SST-2M prototype. The traditional monitoring tools are based on Simple Network Management Protocol (SNMP) and commercial solutions and features embedded in the devices themselves. They generate alerts by email and SMS. The specific custom tools convert the SNMP protocol into the OPC UA protocol and implement an OPC UA server. The server interacts with an OPC UA client implemented in an ACS component that, through the ACS Notification Channel, sends monitor data and alerts to the central console of the ASTRI SST-2M prototype. The same approach has been proposed also for the monitoring of the CTA onsite ICT infrastructures.

  7. A reliable transmission protocol for ZigBee-based wireless patient monitoring.

    PubMed

    Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung

    2012-01-01

    Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

  8. Infection control in healthcare settings: perspectives for mfDNA analysis in monitoring sanitation procedures.

    PubMed

    Valeriani, Federica; Protano, Carmela; Gianfranceschi, Gianluca; Cozza, Paola; Campanella, Vincenzo; Liguori, Giorgio; Vitali, Matteo; Divizia, Maurizio; Romano Spica, Vincenzo

    2016-08-09

    Appropriate sanitation procedures and monitoring of their actual efficacy represent critical points for improving hygiene and reducing the risk of healthcare-associated infections. Presently, surveillance is based on traditional protocols and classical microbiology. Innovation in monitoring is required not only to enhance safety or speed up controls but also to prevent cross infections due to novel or uncultivable pathogens. In order to improve surveillance monitoring, we propose that biological fluid microflora (mf) on reprocessed devices is a potential indicator of sanitation failure, when tested by an mfDNA-based approach. The survey focused on oral microflora traces in dental care settings. Experimental tests (n = 48) and an "in field" trial (n = 83) were performed on dental instruments. Conventional microbiology and amplification of bacterial genes by multiple real-time PCR were applied to detect traces of salivary microflora. Six different sanitation protocols were considered. A monitoring protocol was developed and performance of the mfDNA assay was evaluated by sensitivity and specificity. Contaminated samples resulted positive for saliva traces by the proposed approach (CT < 35). In accordance with guidelines, only fully sanitized samples were considered negative (100 %). Culture-based tests confirmed disinfectant efficacy, but failed in detecting incomplete sanitation. The method provided sensitivity and specificity over 95 %. The principle of detecting biological fluids by mfDNA analysis seems promising for monitoring the effectiveness of instrument reprocessing. The molecular approach is simple, fast and can provide a valid support for surveillance in dental care or other hospital settings.

  9. Validation of the Pangao PG-800B11 blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Bing, Sen; Zhang, Cunhai; Wang, Liping; Li, Linyi; Wan, Yi

    2014-12-01

    The study aimed to determine the accuracy of the fully automated oscillometric upper-arm blood pressure (BP) monitor Pangao PG-800B11 according to the European Society of Hypertension-International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocol 1993. Data from 33 participants were initially examined according to the ESH-IP revision 2010. Furthermore, 52 participants were then enrolled to fulfill the BHS protocol requirements. In all participants, sequential left arm measurements were performed by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The protocols' requirements were followed precisely. The device passed all parts of the ESH protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP) and was graded A according to the criteria of the BHS protocol for both SBP and DBP. The A/A grade was achieved in low (<130/80 mmHg), medium (130-160/80-100 mmHg), and high (>160/100 mmHg) BP categories. The mean BP difference between PG-800B11 and observers in the 85 participants was -0.6±5.0 mmHg for SBP and -0.6±4.5 mmHg for DBP; thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation (AAMI). The Pangao PG-800B11 passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol across a wide range of BPs.

  10. A MORE COST-EFFECTIVE EMAP-ESTUARIES BENTHIC MACROFAUNAL SAMPLING PROTOCOL

    EPA Science Inventory

    The standard benthic macrofaunal sampling protocol in the U.S. Environmental Protection Agency's Pacific Coast Environmental Monitoring and Assessment Program (EMAP) is to collect a minimum of 30 random benthic samples per reporting unit (e.g., estuary) using a 0.1 m2 grab and to...

  11. A MORE COST-EFFECTIVE EMAP BENTHIC MACROFAUNAL SAMPLING PROTOCOL

    EPA Science Inventory

    Benthic macrofaunal sampling protocols in the U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program (EMAP) are to collect 30 to 50 random benthic macrofauna [defined as animals retained on a 0.5 mm (East and Gulf Coasts, USA) or a 1.0 mm mesh siev...

  12. QoS and energy aware cooperative routing protocol for wildfire monitoring wireless sensor networks.

    PubMed

    Maalej, Mohamed; Cherif, Sofiane; Besbes, Hichem

    2013-01-01

    Wireless sensor networks (WSN) are presented as proper solution for wildfire monitoring. However, this application requires a design of WSN taking into account the network lifetime and the shadowing effect generated by the trees in the forest environment. Cooperative communication is a promising solution for WSN which uses, at each hop, the resources of multiple nodes to transmit its data. Thus, by sharing resources between nodes, the transmission quality is enhanced. In this paper, we use the technique of reinforcement learning by opponent modeling, optimizing a cooperative communication protocol based on RSSI and node energy consumption in a competitive context (RSSI/energy-CC), that is, an energy and quality-of-service aware-based cooperative communication routing protocol. Simulation results show that the proposed algorithm performs well in terms of network lifetime, packet delay, and energy consumption.

  13. Data acquisition, detection and estimation for structural health monitoring.

    DOT National Transportation Integrated Search

    2014-05-01

    This project deals with using a wireless sensor network for structural health monitoring. It includes two objectives: (1) to develop : energy-efficient protocols for sensing and communication that are suitable for battery-powered sensor nodes; (2) to...

  14. 40 CFR 62.14740 - What must I include in the deviation report?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That..., and causes for monitoring downtime incidents (other than downtime associated with zero, span, and...

  15. 40 CFR 62.14740 - What must I include in the deviation report?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That..., and causes for monitoring downtime incidents (other than downtime associated with zero, span, and...

  16. 40 CFR 62.14740 - What must I include in the deviation report?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That..., and causes for monitoring downtime incidents (other than downtime associated with zero, span, and...

  17. 40 CFR 62.14740 - What must I include in the deviation report?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That..., and causes for monitoring downtime incidents (other than downtime associated with zero, span, and...

  18. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  19. Protocol Coordinator | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID), Clinical Center (CC), National Institute of Heart, Lung and Blood Institute (NHLBI), National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), National Center for Advancing Translational Sciences (NCATS), National Institute of Neurological Disorders and Stroke (NINDS), and the National Institute of Mental Health (NIMH). Since its inception in 2001, CMRP’s ability to provide rapid responses, high-quality solutions, and to recruit and retain experts with a variety of backgrounds to meet the growing research portfolios of NCI, NIAID, CC, NHLBI, NIAMS, NCATS, NINDS, and NIMH has led to the considerable expansion of the program and its repertoire of support services. CMRP’s support services are strategically aligned with the program’s mission to provide comprehensive, dedicated support to assist National Institutes of Health researchers in providing the highest quality of clinical research in compliance with applicable regulations and guidelines, maintaining data integrity, and protecting human subjects. For the scientific advancement of clinical research, CMRP services include comprehensive clinical trials, regulatory, pharmacovigilance, protocol navigation and development, and programmatic and project management support for facilitating the conduct of 400+ Phase I, II, and III domestic and international trials on a yearly basis. These trials investigate the prevention, diagnosis, treatment of, and therapies for cancer, influenza, HIV, and other infectious diseases and viruses such as hepatitis C, tuberculosis, malaria, and Ebola virus; heart, lung, and blood diseases and conditions; parasitic infections; rheumatic and inflammatory diseases; and rare and neglected diseases. CMRP’s collaborative approach to clinical research and the expertise and dedication of staff to the continuation and success of the program’s mission has contributed to improving the overall standards of public health on a global scale. The Clinical Monitoring Research Program (CMRP) provides comprehensive clinical and administrative support to the National Cancer Institute’s Center for Cancer Research’s (CCR) Protocol Support Office (PSO) for protocol development review, regulatory review, and the implementation process as well as oversees medical writing/editing, regulatory/ compliance, and protocol coordination/navigation and administration. KEY ROLES/RESPONSIBILITIES The Protocol Coordinator III: Provides programmatic and logistical support for the operations of clinical research for Phase I and Phase II clinical trials. Provides deployment of clinical support services for clinical research. Streamlines the protocol development timeline. Provides data and documents collection and compilation for regulatory filing with the U.S. Food and Drug Administration (FDA) and other regulatory authorities.. Provides technical review and report preparation. Provides administrative coordination and general logistical support for regulatory activities. Ensures the provision of training for investigators and associate staff to reinforce and enhance a Good Clinical Practices (GCP) culture. Oversees quality assurance and quality control, performs regulatory review of clinical protocols, informed consent and other clinical documents. Tracks and facilitates a portfolio of protocols through each process step (Institutional Review Board [IRB], Regulatory Affairs Compliance [RAC], Data Safety Monitoring Board [DSMB], Office of Protocol Services). Assists clinical investigators in preparing clinical research protocols, including writing and formatting consent forms. Prepares protocol packages for review and ensures that protocol packages include all of the required material and comply with CCR, NCI and NIH policies. Collaborates with investigators to resolve any protocol/data issues. Coordinates submission of protocols for scientific and ethical review by the Branch scientific review committees, the NCI IRB, and the clinical trial sponsor or the FDA. Monitors the review process and maintains detailed, complete and accurate records for each protocol of the approvals at the various stages of the review process, including new protocol submissions, amendments to protocols, and continuing reviews, as well as other submissions such as adverse events. Attends and prepares minutes for the Branch Protocol Review Committees. Contacts coordinators at other centers for protocols that are performed there to obtain review committee approvals at those centers, maintains records of these approvals and sends protocol amendments and other reports to the participating centers. Maintains a schedule of all review committee submission deadline dates and meeting dates. Assists clinical investigators in understanding and complying with the entire review process. Works closely with the NCI Protocol Review Office in establishing and maintaining a paperless automated document and tracking system for NCI protocols. Converts protocols from Word format to .pdf with bookmarks. Maintains the .pdf version of the most current approved version of each active clinical protocol on a central server. This position is located in Rockville, Maryland.

  20. Medications and Adverse Voice Effects.

    PubMed

    Nemr, Kátia; Di Carlos Silva, Ariana; Rodrigues, Danilo de Albuquerque; Zenari, Marcia Simões

    2017-08-16

    To identify the medications used by patients with dysphonia, describe the voice symptoms reported on initial speech-language pathology (SLP) examination, evaluate the possible direct and indirect effects of medications on voice production, and determine the association between direct and indirect adverse voice effects and self-reported voice symptoms, hydration and smoking habits, comorbidities, vocal assessment, and type and degree of dysphonia. This is a retrospective cross-sectional study. Fifty-five patients were evaluated and the vocal signs and symptoms indicated in the Dysphonia Risk Protocol were considered, as well as data on hydration, smoking and medication use. We analyzed the associations between type of side effect and self-reported vocal signs/symptoms, hydration, smoking, comorbidities, type of dysphonia, and auditory-perceptual and acoustic parameters. Sixty percent were women, the mean age was 51.8 years, 29 symptoms were reported on the screening, and 73 active ingredients were identified with 8.2% directly and 91.8% indirectly affecting vocal function. There were associations between the use of drugs with direct adverse voice effects, self-reported symptoms, general degree of vocal deviation, and pitch deviation. The symptoms of dry throat and shortness of breath were associated with the direct vocal side effect of the medicine, as well as the general degree of vocal deviation and the greater pitch deviation. Shortness of breath when speaking was also associated with the greatest degree of vocal deviation. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  2. Use of an automated decision support tool optimizes clinicians' ability to interpret and appropriately respond to structured self-monitoring of blood glucose data.

    PubMed

    Rodbard, Helena W; Schnell, Oliver; Unger, Jeffrey; Rees, Christen; Amstutz, Linda; Parkin, Christopher G; Jelsovsky, Zhihong; Wegmann, Nathan; Axel-Schweitzer, Matthias; Wagner, Robin S

    2012-04-01

    We evaluated the impact of an automated decision support tool (DST) on clinicians' ability to identify glycemic abnormalities in structured self-monitoring of blood glucose (SMBG) data and then make appropriate therapeutic changes based on the glycemic patterns observed. In this prospective, randomized, controlled, multicenter study, 288 clinicians (39.6% family practice physicians, 37.9% general internal medicine physicians, and 22.6% nurse practitioners) were randomized to structured SMBG alone (STG; n = 72); structured SMBG with DST (DST; n = 72); structured SMBG with an educational DVD (DVD; n = 72); and structured SMBG with DST and the educational DVD (DST+DVD; n = 72). Clinicians analyzed 30 patient cases (type 2 diabetes), identified the primary abnormality, and selected the most appropriate therapy. A total of 222 clinicians completed all 30 patient cases with no major protocol deviations. Significantly more DST, DVD, and DST+DVD clinicians correctly identified the glycemic abnormality and selected the most appropriate therapeutic option compared with STG clinicians: 49, 51, and 55%, respectively, vs. 33% (all P < 0.0001) with no significant differences among DST, DVD, and DST+DVD clinicians. Use of structured SMBG, combined with the DST, the educational DVD, or both, enhances clinicians' ability to correctly identify significant glycemic patterns and make appropriate therapeutic decisions to address those patterns. Structured testing interventions using either the educational DVD or the DST are equally effective in improving data interpretation and utilization. The DST provides a viable alternative when comprehensive education is not feasible, and it may be integrated into medical practices with minimal training.

  3. A randomized controlled trial to compare the effects of sulphonylurea gliclazide MR (modified release) and the DPP-4 inhibitor vildagliptin on glycemic variability and control measured by continuous glucose monitoring (CGM) in Brazilian women with type 2 diabetes.

    PubMed

    Vianna, Andre Gustavo Daher; Lacerda, Claudio Silva; Pechmann, Luciana Muniz; Polesel, Michelle Garcia; Marino, Emerson Cestari; Faria-Neto, Jose Rocha

    2018-05-01

    This study aims to evaluate whether there is a difference between the effects of vildagliptin and gliclazide MR (modified release) on glycemic variability (GV) in women with type 2 diabetes (T2DM) as evaluated by continuous glucose monitoring (CGM). An open-label, randomized study was conducted in T2DM women on steady-dose metformin monotherapy which were treated with 50 mg vildagliptin twice daily or 60-120 mg of gliclazide MR once daily. CGM and GV indices calculation were performed at baseline and after 24 weeks. In total, 42 patients (age: 61.9 ± 5.9 years, baseline glycated hemoglobin (HbA1c): 7.3 ± 0.56) were selected and 37 completed the 24-week protocol. Vildagliptin and gliclazide MR reduced GV, as measured by the mean amplitude of glycemic excursions (MAGE, p = 0.007 and 0.034, respectively). The difference between the groups did not reach statistical significance. Vildagliptin also significantly decreased the standard deviation of the mean glucose (SD) and the mean of the daily differences (MODD) (p = 0.007 and 0.030). Vildagliptin and gliclazide MR similarly reduced the MAGE in women with T2DM after 24 weeks of treatment. Further studies are required to attest differences between vildagliptin and gliclazide MR regarding glycemic variability. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. A liquid chromatography-electrospray ionization-tandem mass spectrometry study of ethanolamines in high salinity industrial wastewaters.

    PubMed

    Campo, Pablo; Suidan, Makram T; Chai, Yunzhou; Davis, John

    2010-01-15

    The detection and quantitation of four ethanolamines, tris(2-hydroxyethyl)amine (triethanolamine, TEA), N,N-bis(2-hydroxyethyl)methylamine (methyldiethanolamine, MDEA), N-(2-aminoethyl)ethanolamine (AEA), and N,N-diethylethanolamine (DEA), were achieved in wastewaters from two aerobic activated sludge bioreactors located in an industrial wastewater treatment plant. The streams had salt concentrations of approximately 3% and 7% by weight in Reactor 1 and Reactor 2, respectively. The use of liquid chromatography-electrospray ionization-tandem mass spectrometry avoided the need for some sample preparation steps such as extraction, concentration, and derivatization. Ion suppression in the electrospray, attributable to the presence of sodium clusters, was attenuated by a 10-fold dilution of the wastewaters with acetonitrile. A matrix-matched calibration model averted other potential interferences. For the compounds analyzed in selected reaction monitoring mode (TEA, MDEA, and DEA), the calibration curves presented linearity in a range of 10-1000microg/L with corresponding detection limits ranging from 2 to 11microg/L, depending upon the specific analyte and aqueous matrix. AEA was calibrated in selected ion monitoring mode (100-1000microg/L), with corresponding detection limits in the two wastewaters of 74.6 and 85.3microg/L, respectively. Overall good precision (<10%) and accuracy (97-110%) were achieved for both matrices, which fell within-laboratory reproducibility. Finally, the amines were introduced into six mixed liquor samples from both reactors and quantified following the reported protocol. Again, recoveries were close to 100% with a relative standard deviation of less than 10% in all cases.

  5. Prediction of human core body temperature using non-invasive measurement methods.

    PubMed

    Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel

    2014-01-01

    The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.

  6. 40 CFR 60.2780 - What must I include in the deviation report?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Compliance Times for Commercial and Industrial Solid Waste Incineration Units that Commenced Construction On... causes for monitoring downtime incidents (other than downtime associated with zero, span, and other...

  7. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  8. Vibration monitoring of Kraftwerk Union pressurized water reactors - Review, present status, and further development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stolben, H.; Wehling, H.J.

    Incipient damage to mechanical structure may be detected early in time by deviations from normal dynamic behavior. For vibration monitoring of coupled systems, only a small number of transducers are necessary, in general. On the basis, Kraftwerk Union has been involved in the development and construction of vibration monitoring systems for pressurized water reactors over the last 20 yr. The current state of the art permits vibration monitoring during normal operation by reactor personnel without expert assistance. The new SUS-86 microprocessor-based system allows further expansion toward an expert system.

  9. Urban forest health monitoring: large-scale assessments in the United States

    Treesearch

    Anne Buckelew Cumming; Daniel B. Twardus; David J. Nowak

    2008-01-01

    The U.S. Department of Agriculture, Forest Service (USFS), together with state partners, developed methods to monitor urban forest structure, function, and health at a large statewide scale. Pilot studies have been established in five states using protocols based on USFS Forest Inventory and Analysis and Forest Health Monitoring program data collection standards....

  10. National best management practices monitoring summary report, program phase-in period fiscal years 2013-2014

    Treesearch

    Joan Carlson; Pam Edwards; Todd Ellsworth; Michael Eberle

    2015-01-01

    The National BMP Program provides National Core BMPs, standardized monitoring protocols to evaluate implementation and effectiveness of the National Core BMPs, and a data management system to store and analyze the resulting monitoring data. BMP evaluations are completed by interdisciplinary teams of resource specialists and include assessments of whether BMP...

  11. Ground-based photo monitoring

    Treesearch

    Frederick C. Hall

    2000-01-01

    Ground-based photo monitoring is repeat photography using ground-based cameras to document change in vegetation or soil. Assume those installing the photo location will not be the ones re-photographing it. This requires a protocol that includes: (1) a map to locate the monitoring area, (2) another map diagramming the photographic layout, (3) type and make of film such...

  12. LiMPETS: Scientists Contributions to Coastal Protection Program for Youth

    NASA Astrophysics Data System (ADS)

    Saltzman, J.; Osborn, D. A.

    2004-12-01

    In the West Coast National Marine Sanctuaries' LiMPETS (Long-term Monitoring Experiential Training for Students), scientists have partnered with local sanctuaries to develop an educational and scientifically-based monitoring program. With different levels of commitment and interest, scientists have contributed to developing protocols that youth can successfully use to monitor coastal habitats. LiMPETS was developed to address the gap in marine science education for high school students. The team of sanctuary educators together with local scientists collaborate and compromise to develop scientifically accurate and meaningful monitoring projects. By crossing the border between scientists and educators, LiMPETS has become a rich program which provides to teachers professional development, monitoring equipment, an online database, and field support. In the Sandy Beach Monitoring Project, we called on an expert on the sand crab Emerita analoga to help us modify the protocols that she uses to monitor crabs regularly. This scientist brings inspiration to teachers at teacher workshops by explaining how the student monitoring compliments her research. The Rocky Intertidal Monitoring Project was developed by scientists at University of California at Santa Cruz with the intention of passing on this project to an informal learning center. After receiving California Sea Grant funding, the protocols used for over 30 years with undergraduates were modified for middle and high school students. With the help of teachers, classroom activities were developed to train students for fieldwork. The online database was envisioned by the scientists to house the historical data from undergraduate students while growing with new data collected middle and high school students. The support of scientists in this program has been crucial to develop a meaningful program for both youth and resource managers. The hours that a scientist contributes to this program may be minimal, a weeklong workshop or even a part-time job. The framework of resource protection agencies partnering with scientists can be replicated to monitor other natural habitats. Through LiMPETS, scientists are helping to develop scientifically literate youth who are engaged in environmental monitoring.

  13. Monitoring gradient profile on-line in micro- and nano-high performance liquid chromatography using conductivity detection.

    PubMed

    Zhang, Min; Chen, Apeng; Lu, Joann J; Cao, Chengxi; Liu, Shaorong

    2016-08-19

    In micro- or nano-flow high performance liquid chromatography (HPLC), flow-splitters and gradient elutions are commonly used for reverse phase HPLC separations. When a flow splitter was used at a high split-ratio (e.g., 1000:1 or higher), the actual gradient may deviate away from the programmed gradient. Sometimes, mobile phase concentrations can deviate by as much as 5%. In this work, we noticed that the conductivity (σ) of a gradient decreased with the increasing organic-solvent fraction (φ). Based on the relationship between σ and φ, a method was developed for monitoring gradient profile on-line to record any deviations in these HPLC systems. The conductivity could be measured by a traditional conductivity detector or a capacitively coupled contactless conductivity detector (C(4)D). The method was applied for assessing the performance of an electroosmotic pump (EOP) based nano-HPLC. We also observed that σ value of the gradient changed with system pressure; a=0.0175ΔP (R(2)=0.964), where a is the percentage of the conductivity increase and ΔP is the system pressure in bar. This effect was also investigated. Copyright © 2016. Published by Elsevier B.V.

  14. Team Cappadocia Design for MAGIC 2010 (The ASELSAN Team)

    DTIC Science & Technology

    2010-11-01

    Also in another screen, OCU displays tactical information using 3D Geographical Information System (GIS) for enhanced situational awareness. OCU...number of local textural features such as mean and standard deviation of image intensity and gradient, Zernike moments, Haralick features...information for situational awareness on the 3D GIS tactical map and the other monitor is used for UGV status monitoring, command and control. Tactical

  15. [Study on the reproducibility of ACTH concentrations in plasma of horses with and without equine Cushing syndrome].

    PubMed

    Gehlen, Heidrun; Bradaric, Zrinkja

    2013-01-01

    The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.

  16. Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, J. A.; Booth, J. T.; O’Brien, R. T.

    2014-11-01

    Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time 3D tumor monitoring system for cancer radiotherapy. KIM uses the commonly available gantry-mounted x-ray imager as input, making this method potentially more widely available than dedicated real-time 3D tumor monitoring systems. KIM is being piloted in a clinical trial for prostate cancer patients treated with VMAT (NCT01742403). The purpose of this work was to develop clinical process and quality assurance (QA) practices for the clinical implementation of KIM. Methods: Informed by and adapting existing guideline documents from other real-time monitoring systems, KIM-specific QA practices were developed. The following five KIM-specific QA testsmore » were included: (1) static localization accuracy, (2) dynamic localization accuracy, (3) treatment interruption accuracy, (4) latency measurement, and (5) clinical conditions accuracy. Tests (1)–(4) were performed using KIM to measure static and representative patient-derived prostate motion trajectories using a 3D programmable motion stage supporting an anthropomorphic phantom with implanted gold markers to represent the clinical treatment scenario. The threshold for system tolerable latency is <1 s. The tolerances for all other tests are that both the mean and standard deviation of the difference between the programmed trajectory and the measured data are <1 mm. The (5) clinical conditions accuracy test compared the KIM measured positions with those measured by kV/megavoltage (MV) triangulation from five treatment fractions acquired in a previous pilot study. Results: For the (1) static localization, (2) dynamic localization, and (3) treatment interruption accuracy tests, the mean and standard deviation of the difference are <1.0 mm. (4) The measured latency is 350 ms. (5) For the tests with previously acquired patient data, the mean and standard deviation of the difference between KIM and kV/MV triangulation are <1.0 mm. Conclusions: Clinical process and QA practices for the safe clinical implementation of KIM, a novel real-time monitoring system using commonly available equipment, have been developed and implemented for prostate cancer VMAT.« less

  17. An Integrated Patient Information and In-Home Health Monitoring System Using Smartphones and Web Services.

    PubMed

    Sorwar, Golam; Ali, Mortuza; Islam, Md Kamrul; Miah, Mohammad Selim

    2016-01-01

    Modern healthcare systems are undergoing a paradigm shift from in-hospital care to in-home monitoring, leveraging the emerging technologies in the area of bio-sensing, wireless communication, mobile computing, and artificial intelligence. In-home monitoring promises to significantly reduce healthcare spending by preventing unnecessary hospital admissions and visits to healthcare professionals. Most of the in-home monitoring systems, proposed in the literature, focus on monitoring a set of specific vital signs. However, from the perspective of caregivers it is infeasible to maintain a collection of specialized monitoring systems. In this paper, we view the problem of in-home monitoring from the perspective of caregivers and present a framework that supports various monitoring capabilities while making the complexity transparent to the end users. The essential idea of the framework is to define a 'general purpose architecture' where the system specifies a particular protocol for communication and makes it public. Then any bio-sensing system can communicate with the system as long as it conforms to the protocol. We then argue that as the system grows in terms of number of patients and bio-sensing systems, artificial intelligence technologies need to be employed for patients' risk assessment, prioritization, and recommendation. Finally, we present an initial prototype of the system designed according to the proposed framework.

  18. Welding wire pressure sensor assembly

    NASA Technical Reports Server (NTRS)

    Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)

    1994-01-01

    The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.

  19. Challenges in coupling LTER with environmental assessments: An insight from potential and reality of the Chinese Ecological Research Network in servicing environment assessments.

    PubMed

    Xia, Shaoxia; Liu, Yu; Yu, Xiubo; Fu, Bojie

    2018-08-15

    Environmental assessments estimate, evaluate and predict the consequences of natural processes and human activities on the environment. Long-term ecosystem observation and research networks (LTERs) are potentially valuable infrastructure to support environmental assessments. However, very few environmental assessments have successfully incorporated them. In this study, we try to reveal the current status of coupling LTERs with environmental assessments and look at the challenges involved in improving this coupling through exploring the role that Chinese Ecological Research Network (CERN), the LTER of China, currently plays in regional environment assessments. A review of official protocols and standards, regional assessments and CERN researches related to ecosystems and environment shows that there is great potential for coupling CERN with environment assessments. However in practice, CERN does not currently play the expected role. Remote sensing and irregular inventory data are still the main data sources currently used in regional assessments. Several causes led to the present situation: (1) insufficient cross-site research and failure to scale up site-level variables to the regional scale; (2) data barriers resulting from incompatible protocols and low data usability due to lack of data assimilation and scaling; and (3) absence of indicators relevant to human activities in existing monitoring protocols. For these reasons, enhancing cross-site monitoring and research, data assimilation and scaling up are critical steps required to improve coupling of LTER with environmental assessments. Site-focused long-term monitoring should be combined with wide-scale ground surveys and remote sensing to establish an effective connection between different environmental monitoring platforms for regional assessments. It is also necessary to revise the current monitoring protocols to include human activities and their impacts on the ecosystem, or change the LTERs into Long-Term Socio-Ecological Research (LTSER) networks. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Implementation of a Lateral TBI protocol in a Mexican Cancer Center

    NASA Astrophysics Data System (ADS)

    Mesa, Francisco; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko; Sosa, Modesto A.

    2008-08-01

    The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5% respect of the prescribed dose.

  1. Determination of absorbed dose to water for high-energy photon and electron beams-comparison of the standards DIN 6800-2 (1997), IAEA TRS 398 (2000) and DIN 6800-2 (2006)

    PubMed Central

    Zakaria, Golam Abu; Schuette, Wilhelm

    2007-01-01

    For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit. PMID:21217912

  2. Determination of absorbed dose to water for high-energy photon and electron beams-comparison of the standards DIN 6800-2 (1997), IAEA TRS 398 (2000) and DIN 6800-2 (2006).

    PubMed

    Zakaria, Golam Abu; Schuette, Wilhelm

    2007-01-01

    For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit.

  3. Development and layout of a protocol for the field performance of concrete deck and crack sealers.

    DOT National Transportation Integrated Search

    2009-09-01

    The main objective of this project was to develop and layout a protocol for the long-term monitoring and assessment of the performance of concrete deck and crack sealants in the field. To accomplish this goal, a total of six bridge decks were chosen ...

  4. Bioassessment Tools for Stony Corals: Field Testing of Monitoring Protocols in the US Virgin Islands (St. Croix)

    EPA Science Inventory

    Survey protocols for assessing coral reef condition were field tested at 61 reef stations in St. Croix, US Virgin Islands (USVI) during 2006. Three observations for stony corals were recorded: species, size, and percent live tissue. Stony corals were selected because they are pri...

  5. Initiation and Use of Propranolol for Infantile Hemangioma: Report of a Consensus Conference

    PubMed Central

    Frommelt, Peter C.; Chamlin, Sarah L.; Haggstrom, Anita; Bauman, Nancy M.; Chiu, Yvonne E.; Chun, Robert H.; Garzon, Maria C.; Holland, Kristen E.; Liberman, Leonardo; MacLellan-Tobert, Susan; Mancini, Anthony J.; Metry, Denise; Puttgen, Katherine B.; Seefeldt, Marcia; Sidbury, Robert; Ward, Kendra M.; Blei, Francine; Baselga, Eulalia; Cassidy, Laura; Darrow, David H.; Joachim, Shawna; Kwon, Eun-Kyung M.; Martin, Kari; Perkins, Jonathan; Siegel, Dawn H.; Boucek, Robert J.; Frieden, Ilona J.

    2013-01-01

    Infantile hemangiomas (IHs) are common neoplasms composed of proliferating endothelial-like cells. Despite the relative frequency of IH and the potential severity of complications, there are currently no uniform guidelines for treatment. Although propranolol has rapidly been adopted, there is significant uncertainty and divergence of opinion regarding safety monitoring, dose escalation, and its use in PHACE syndrome (PHACE = posterior fossa, hemangioma, arterial lesions, cardiac abnormalities, eye abnormalities; a cutaneous neurovascular syndrome characterized by large, segmental hemangiomas of the head and neck along with congenital anomalies of the brain, heart, eyes and/or chest wall). A consensus conference was held on December 9, 2011. The multidisciplinary team reviewed existing data on the pharmacologic properties of propranolol and all published reports pertaining to the use of propranolol in pediatric patients. Workgroups were assigned specific topics to propose protocols on the following subjects: contraindications, special populations, pretreatment evaluation, dose escalation, and monitoring. Consensus protocols were recorded during the meeting and refined after the meeting. When appropriate, protocol clarifications and revision were made and agreed upon by the group via teleconference. Because of the absence of high-quality clinical research data, evidence-based recommendations are not possible at present. However, the team agreed on a number of recommendations that arose from a review of existing evidence, including when to treat complicated IH; contraindications and pretreatment evaluation protocols; propranolol use in PHACE syndrome; formulation, target dose, and frequency of propranolol; initiation of propranolol in infants; cardiovascular monitoring; ongoing monitoring; and prevention of hypoglycemia. Where there was considerable controversy, the more conservative approach was selected. We acknowledge that the recommendations are conservative in nature and anticipate that they will be revised as more data are made available. PMID:23266923

  6. Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.

    PubMed

    Zeng, Wei-Fang; Kang, Yuan-Yuan; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2013-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor A&D UA-1020 with two different-shaped cuffs for home BP monitoring according to the British Hypertension Society (BHS) Protocol. We recruited individuals for each of the two cuffs (D-ring and cylindrical) until there were 85 eligible participants (255 pairs of comparisons) and their BP could meet the BP distribution requirements specified by the BHS Protocol. For each participant, we sequentially measured the systolic and diastolic BP using a mercury sphygmomanometer (two observers) and the UA-1020 device (one supervisor). For the D-ring cuff, the device achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 87, and 96%, respectively, for systolic BP, and 70, 90, and 99%, respectively, for diastolic BP. The average (±SD) of the device-observer differences was -0.2±7.3 mmHg (P=0.64) and 1.7±5.8 mmHg (P<0.0001) for systolic and diastolic BP, respectively. For the cylindrical cuff, the device also achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 88, and 97%, respectively, for systolic BP and 64, 89, and 98%, respectively, for diastolic BP. The average of the device-observer differences was -0.1±7.0 mmHg (P=0.89) and 2.0±6.3 mmHg (P<0.0001) for systolic and diastolic BP, respectively. The UA-1020 device has passed the requirements of the BHS Protocol with both the D-ring and the cylindrical cuffs, and hence can be recommended for home use in adults.

  7. Initiation and use of propranolol for infantile hemangioma: report of a consensus conference.

    PubMed

    Drolet, Beth A; Frommelt, Peter C; Chamlin, Sarah L; Haggstrom, Anita; Bauman, Nancy M; Chiu, Yvonne E; Chun, Robert H; Garzon, Maria C; Holland, Kristen E; Liberman, Leonardo; MacLellan-Tobert, Susan; Mancini, Anthony J; Metry, Denise; Puttgen, Katherine B; Seefeldt, Marcia; Sidbury, Robert; Ward, Kendra M; Blei, Francine; Baselga, Eulalia; Cassidy, Laura; Darrow, David H; Joachim, Shawna; Kwon, Eun-Kyung M; Martin, Kari; Perkins, Jonathan; Siegel, Dawn H; Boucek, Robert J; Frieden, Ilona J

    2013-01-01

    Infantile hemangiomas (IHs) are common neoplasms composed of proliferating endothelial-like cells. Despite the relative frequency of IH and the potential severity of complications, there are currently no uniform guidelines for treatment. Although propranolol has rapidly been adopted, there is significant uncertainty and divergence of opinion regarding safety monitoring, dose escalation, and its use in PHACE syndrome (PHACE = posterior fossa, hemangioma, arterial lesions, cardiac abnormalities, eye abnormalities; a cutaneous neurovascular syndrome characterized by large, segmental hemangiomas of the head and neck along with congenital anomalies of the brain, heart, eyes and/or chest wall). A consensus conference was held on December 9, 2011. The multidisciplinary team reviewed existing data on the pharmacologic properties of propranolol and all published reports pertaining to the use of propranolol in pediatric patients. Workgroups were assigned specific topics to propose protocols on the following subjects: contraindications, special populations, pretreatment evaluation, dose escalation, and monitoring. Consensus protocols were recorded during the meeting and refined after the meeting. When appropriate, protocol clarifications and revision were made and agreed upon by the group via teleconference. Because of the absence of high-quality clinical research data, evidence-based recommendations are not possible at present. However, the team agreed on a number of recommendations that arose from a review of existing evidence, including when to treat complicated IH; contraindications and pretreatment evaluation protocols; propranolol use in PHACE syndrome; formulation, target dose, and frequency of propranolol; initiation of propranolol in infants; cardiovascular monitoring; ongoing monitoring; and prevention of hypoglycemia. Where there was considerable controversy, the more conservative approach was selected. We acknowledge that the recommendations are conservative in nature and anticipate that they will be revised as more data are made available.

  8. On the ability of consumer electronics microphones for environmental noise monitoring.

    PubMed

    Van Renterghem, Timothy; Thomas, Pieter; Dominguez, Frederico; Dauwe, Samuel; Touhafi, Abdellah; Dhoedt, Bart; Botteldooren, Dick

    2011-03-01

    The massive production of microphones for consumer electronics, and the shift from dedicated processing hardware to PC-based systems, opens the way to build affordable, extensive noise measurement networks. Applications include e.g. noise limit and urban soundscape monitoring, and validation of calculated noise maps. Microphones are the critical components of such a network. Therefore, in a first step, some basic characteristics of 8 microphones, distributed over a wide range of price classes, were measured in a standardized way in an anechoic chamber. In a next step, a thorough evaluation was made of the ability of these microphones to be used for environmental noise monitoring. This was done during a continuous, half-year lasting outdoor experiment, characterized by a wide variety of meteorological conditions. While some microphones failed during the course of this test, it was shown that it is possible to identify cheap microphones that highly correlate to the reference microphone during the full test period. When the deviations are expressed in total A-weighted (road traffic) noise levels, values of less than 1 dBA are obtained, in excess to the deviation amongst reference microphones themselves.

  9. A Survey on Underwater Acoustic Sensor Network Routing Protocols.

    PubMed

    Li, Ning; Martínez, José-Fernán; Meneses Chaus, Juan Manuel; Eckert, Martina

    2016-03-22

    Underwater acoustic sensor networks (UASNs) have become more and more important in ocean exploration applications, such as ocean monitoring, pollution detection, ocean resource management, underwater device maintenance, etc. In underwater acoustic sensor networks, since the routing protocol guarantees reliable and effective data transmission from the source node to the destination node, routing protocol design is an attractive topic for researchers. There are many routing algorithms have been proposed in recent years. To present the current state of development of UASN routing protocols, we review herein the UASN routing protocol designs reported in recent years. In this paper, all the routing protocols have been classified into different groups according to their characteristics and routing algorithms, such as the non-cross-layer design routing protocol, the traditional cross-layer design routing protocol, and the intelligent algorithm based routing protocol. This is also the first paper that introduces intelligent algorithm-based UASN routing protocols. In addition, in this paper, we investigate the development trends of UASN routing protocols, which can provide researchers with clear and direct insights for further research.

  10. A Survey on Underwater Acoustic Sensor Network Routing Protocols

    PubMed Central

    Li, Ning; Martínez, José-Fernán; Meneses Chaus, Juan Manuel; Eckert, Martina

    2016-01-01

    Underwater acoustic sensor networks (UASNs) have become more and more important in ocean exploration applications, such as ocean monitoring, pollution detection, ocean resource management, underwater device maintenance, etc. In underwater acoustic sensor networks, since the routing protocol guarantees reliable and effective data transmission from the source node to the destination node, routing protocol design is an attractive topic for researchers. There are many routing algorithms have been proposed in recent years. To present the current state of development of UASN routing protocols, we review herein the UASN routing protocol designs reported in recent years. In this paper, all the routing protocols have been classified into different groups according to their characteristics and routing algorithms, such as the non-cross-layer design routing protocol, the traditional cross-layer design routing protocol, and the intelligent algorithm based routing protocol. This is also the first paper that introduces intelligent algorithm-based UASN routing protocols. In addition, in this paper, we investigate the development trends of UASN routing protocols, which can provide researchers with clear and direct insights for further research. PMID:27011193

  11. Manufacturing/Cell Therapy Specialist | Center for Cancer Research

    Cancer.gov

    Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID), Clinical Center (CC), National Institute of Heart, Lung and Blood Institute (NHLBI), National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), National Center for Advancing Translational Sciences (NCATS), National Institute of Neurological Disorders and Stroke (NINDS), and the National Institute of Mental Health (NIMH). Since its inception in 2001, CMRP’s ability to provide rapid responses, high-quality solutions, and to recruit and retain experts with a variety of backgrounds to meet the growing research portfolios of NCI, NIAID, CC, NHLBI, NIAMS, NCATS, NINDS, and NIMH has led to the considerable expansion of the program and its repertoire of support services. CMRP’s support services are strategically aligned with the program’s mission to provide comprehensive, dedicated support to assist National Institutes of Health researchers in providing the highest quality of clinical research in compliance with applicable regulations and guidelines, maintaining data integrity, and protecting human subjects. For the scientific advancement of clinical research, CMRP services include comprehensive clinical trials, regulatory, pharmacovigilance, protocol navigation and development, and programmatic and project management support for facilitating the conduct of 400+ Phase I, II, and III domestic and international trials on a yearly basis. These trials investigate the prevention, diagnosis, treatment of, and therapies for cancer, influenza, HIV, and other infectious diseases and viruses such as hepatitis C, tuberculosis, malaria, and Ebola virus; heart, lung, and blood diseases and conditions; parasitic infections; rheumatic and inflammatory diseases; and rare and neglected diseases. CMRP’s collaborative approach to clinical research and the expertise and dedication of staff to the continuation and success of the program’s mission has contributed to improving the overall standards of public health on a global scale. The Clinical Monitoring Research Program (CMRP) provides cell culture experience to work on innovative Vector Production and T-cell therapies for cancer treatment, and responsible for cell culture media preparation, vector production, and/or cell processing and cell expansion in the cGMP clinical manufacturing facility in support of the National Cancer Institute’s (NCI’s), Center for Cancer Research (CCR), Surgery Branch (SB). KEY ROLES/RESPONSIBILITIES-THIS POSITION IS CONTINGENT UPON FUNDING APPROVAL Performs testing of raw materials, intermediates, and final products by following analytical methods Maintains, calibrates and operates equipment and instruments supporting cell bioassays, Flow Cytometry, ELISA and PCR assay Tracks and tests products according to protocols Maintains lab in an optimal state Monitors and trends data, completes routine record review of test data and related documents for in-process testing, drug substance and drug product release Generates CoAs for product release Assists in the preparation of dossiers and data packages for interactions between Surgery Branch and Regulatory agencies Develops, revises, and reviews SOPs, qualification/validation protocols and reports Participates in investigations regarding out of specifications (OOS) results; address and manage deviations related to analytical procedures Provides updates at daily and weekly meetings Monitors the GMP systems currently in place to ensure compliance with documented policies Reviews proposed changes to systems, procedures, methods, and submissions to regulatory agencies, as appropriate Gathers metric information for use in continuous improvement of areas of responsibility May develop testing and analysis methods and procedures in accordance with established guidelines

  12. BATHING BEACH MONITORING PROTOCOLS/COMMUNICATING SWIMMING ACTIVITY RISK TO THE PUBLIC

    EPA Science Inventory

    Current Environmental Protection Agency (EPA) recommended monitoring practices for bathing beach water quality were suggested in 1968, as a part of the fecal coliform guideline developed by the Federal Water Pollution Control Administration. The guideline stated that five water ...

  13. RED RIVER BASIN BIOLOGICAL MONITORING WORKGROUP

    EPA Science Inventory

    The goal of this project is to improve coordination of biological monitoring efforts in the Red River Basin. This is to be accomplished through coordination of a study to develop sampling protocols for macroinvertebrates in the main stream and lower tributaries of the Red River....

  14. Protocol adherence and the ability to achieve target haemoglobin levels in haemodialysis patients.

    PubMed

    Chan, Kevin; Moran, John; Hlatky, Mark; Lafayette, Richard

    2009-06-01

    Anemia management remains complicated in patients with endstage renal disease on hemodialysis. We wished to evaluate the effect of protocol adherence to EPO and intravenous iron dosing on achieving the desired range of hemoglobin levels. A cohort of hemodialysis patients was studied to evaluate the rate of adherence to EPO and iron dosing protocols over a 5 month period. A database was completed to evaluate all known comorbidities, demographic factors, and facility issues that might affect hemoglobin levels. A logistic regression model was employed to evaluate the effect of adherence to the anemia protocols on the probability of achieving a hemoglobin level below, within or above the targeted range of 11-12.5 g/dl. Among 2114 patients, we found that adherence to both the EPO and iron dosing protocol resulted in the greatest probability of achieving the target hemoglobin range (56 +/- 5% in anemia protocol adherent patients versus 42 +/- 7% in non adherent patients). This was predominantly due to a lowered risk of having above target hemoglobin levels rather than below. The use of the anemia protocols was associated with lower rates of hospitalization (9 +/- 0.7 visits/100 months in adherent group vs 15 +/- 2 in non adherent group) and lower utilization of both EPO and intravenous iron. Furthermore, patients in the adherent groups had less variability of their hemoglobin levels month by month, at least as judged by standard deviation. Adherence to anemia protocols, as practiced in the dialysis units included in this cohort, may improve hemodialysis patients' ability to achieve target hemoglobin levels, and by avoiding above target hemoglobin values, lower drug utilization and reduce variability of hemoglobin levels.

  15. The Utility of a Benign Biliary Stricture Protocol in Preventing Symptomatic Recurrence and Surgical Revision.

    PubMed

    Kirkpatrick, Daniel L; Hasham, Hasnain; Collins, Zachary; Johnson, Philip; Lemons, Steven; Shahzada, Hassan; Hunt, Suzanne L; Walter, Carissa; Hill, Jacqueline; Fahrbach, Thomas

    2018-05-01

    To determine whether treating benign biliary strictures via a stricture protocol reduced the probability of developing symptomatic recurrence and requiring surgical revision compared to nonprotocol treatment. A stricture protocol was designed to include serial upsizing of internal/external biliary drainage catheters to a target maximum dilation of 18-French, optional cholangioplasty at each upsizing, and maintenance of the largest catheter for at least 6 months. Patients were included in this retrospective analysis if they underwent biliary ductal dilation at a single institution from 2005 to 2016. Forty-two patients were included, 25 women and 17 men, with an average age of 51.9 years (standard deviation ± 14.6). Logistic regression models were used to determine the probability of symptomatic recurrence and surgical revision by stricture treatment type. Twenty-two patients received nonprotocol treatment, while 20 received treatment on a stricture protocol. After treatment, 7 (32%) patients in the nonprotocol group experienced clinical or laboratory recurrence of a benign stricture, whereas only 1 patient in the stricture protocol group experienced symptom recurrence. Patients in the protocol group were 8.9 times (95% confidence interval [CI] = 1.4-175.3) more likely to remain symptom free than patients in the nonprotocol group. Moreover, patients in the protocol group had an estimated 89% reduction in the probability of undergoing surgical revision compared to patients receiving nonprotocol treatment (odds ratio = .11, 95% CI = .01-.73). Establishing a stricture protocol may decrease the risk of stricture recurrence and the need for surgical revision when compared to a nonprotocol treatment approach. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  16. An emergency-adaptive routing scheme for wireless sensor networks for building fire hazard monitoring.

    PubMed

    Zeng, Yuanyuan; Sreenan, Cormac J; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin

    2011-01-01

    Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work.

  17. An Emergency-Adaptive Routing Scheme for Wireless Sensor Networks for Building Fire Hazard Monitoring

    PubMed Central

    Zeng, Yuanyuan; Sreenan, Cormac J.; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin

    2011-01-01

    Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work. PMID:22163774

  18. The Integrated Safety-Critical Advanced Avionics Communication and Control (ISAACC) System Concept: Infrastructure for ISHM

    NASA Technical Reports Server (NTRS)

    Gwaltney, David A.; Briscoe, Jeri M.

    2005-01-01

    Integrated System Health Management (ISHM) architectures for spacecraft will include hard real-time, critical subsystems and soft real-time monitoring subsystems. Interaction between these subsystems will be necessary and an architecture supporting multiple criticality levels will be required. Demonstration hardware for the Integrated Safety-Critical Advanced Avionics Communication & Control (ISAACC) system has been developed at NASA Marshall Space Flight Center. It is a modular system using a commercially available time-triggered protocol, ?Tp/C, that supports hard real-time distributed control systems independent of the data transmission medium. The protocol is implemented in hardware and provides guaranteed low-latency messaging with inherent fault-tolerance and fault-containment. Interoperability between modules and systems of modules using the TTP/C is guaranteed through definition of messages and the precise message schedule implemented by the master-less Time Division Multiple Access (TDMA) communications protocol. "Plug-and-play" capability for sensors and actuators provides automatically configurable modules supporting sensor recalibration and control algorithm re-tuning without software modification. Modular components of controlled physical system(s) critical to control algorithm tuning, such as pumps or valve components in an engine, can be replaced or upgraded as "plug and play" components without modification to the ISAACC module hardware or software. ISAACC modules can communicate with other vehicle subsystems through time-triggered protocols or other communications protocols implemented over Ethernet, MIL-STD- 1553 and RS-485/422. Other communication bus physical layers and protocols can be included as required. In this way, the ISAACC modules can be part of a system-of-systems in a vehicle with multi-tier subsystems of varying criticality. The goal of the ISAACC architecture development is control and monitoring of safety critical systems of a manned spacecraft. These systems include spacecraft navigation and attitude control, propulsion, automated docking, vehicle health management and life support. ISAACC can integrate local critical subsystem health management with subsystems performing long term health monitoring. The ISAACC system and its relationship to ISHM will be presented.

  19. ABM Clinical Protocol #1: Guidelines for Blood Glucose Monitoring and Treatment of Hypoglycemia in Term and Late-Preterm Neonates, Revised 2014

    PubMed Central

    Wight, Nancy

    2014-01-01

    A central goal of The Academy of Breastfeeding Medicine is the development of clinical protocols for managing common medical problems that may impact breastfeeding success. These protocols serve only as guidelines for the care of breastfeeding mothers and infants and do not delineate an exclusive course of treatment or serve as standards of medical care. Variations in treatment may be appropriate according to the needs of an individual patient. PMID:24823918

  20. Does instruction to eliminate coffee, tea, alcohol, carbonated, and artificially sweetened beverages improve lower urinary tract symptoms: A Prospective Trial

    PubMed Central

    Miller, Janis M.; Garcia, Caroline E.; Hortsch, Sarah Becker; Guo, Ying; Schimpf, Megan O.

    2016-01-01

    Purpose Common advice for lower urinary tract symptoms (LUTS) of frequency, urgency and related bother includes elimination of potentially irritating beverages (coffee, tea, alcohol, and carbonated and/or artificially sweetened beverages). The purpose of this study was to determine compliance with standardized instruction to eliminate these potentially irritating beverages, whether LUTS improved after instruction, and if symptoms worsened with partial reintroduction. Design The three-phase fixed sequence design was: 1) baseline, 2) eliminate potentially irritating beverages listed above, and 3) reintroduce at 50% of baseline volume, with a washout period between each 3-day phase. We asked participants to maintain total intake volume by swapping in equal amounts of non-potentially irritating beverages (primarily water). Subjects and Setting The study sample comprised 30 community-dwelling women recruited through newspaper advertisement. Methods Quantification measures included 3-day voiding diaries and detailed beverage intake, and LUTS questionnaires completed during each phase. Results During Phase 2, we found significant reduction in potentially irritating beverages but complete elimination was rare. Despite the protocol demands, total beverage intake was not stable; mean (± standard deviation) daily total intake volume dropped by 6.2±14.9oz (p=0.03) during Phase 2. In Phase 3, the volume of total beverage intake returned to baseline, but intake of potentially irritating beverages also returned to near baseline rather than 50% as requested by protocol. Despite this incomplete adherence to study protocols, women reported reduction in symptoms of urge, inability to delay voiding, and bother during both phases (p≤0.01). The number of voids per day decreased on average by 1.3 and 0.9 voids during phases 2 and 3 respectively (p=0.002 and p=0.035). Conclusions Education to reduce potentially irritating beverages resulted in improvement in LUTS. However, eliminating potentially irritating beverages was difficult to achieve and maintain. Study findings do not allow us to determine if LUTS improvement was attributable to intake of fewer potentially irritating beverages, reduced intake of all beverages, the effect of self-monitoring, or some combination of these factors. PMID:26727685

  1. Does Instruction to Eliminate Coffee, Tea, Alcohol, Carbonated, and Artificially Sweetened Beverages Improve Lower Urinary Tract Symptoms?: A Prospective Trial.

    PubMed

    Miller, Janis M; Garcia, Caroline E; Hortsch, Sarah Becker; Guo, Ying; Schimpf, Megan O

    2016-01-01

    Common advice for lower urinary tract symptoms (LUTS) such as frequency, urgency, and related bother includes elimination of potentially irritating beverages (coffee, tea, alcohol, and carbonated and/or artificially sweetened beverages). The purpose of this study was to determine compliance with standardized instruction to eliminate these potentially irritating beverages, whether LUTS improved after instruction, and whether symptoms worsened with partial reintroduction. The 3-phase fixed sequence design was (1) baseline, (2) eliminate potentially irritating beverages listed above, and (3) reintroduce at 50% of baseline volume, with a washout period between each 3-day phase. We asked participants to maintain total intake volume by swapping in equal amounts of nonpotentially irritating beverages (primarily water). The study sample comprised 30 community-dwelling women recruited through newspaper advertisement. Quantification measures included 3-day voiding diaries and detailed beverage intake, and LUTS questionnaires completed during each phase. During Phase 2, we found significant reduction in potentially irritating beverages but complete elimination was rare. Despite protocol demands, total beverage intake was not stable; mean (± standard deviation) daily total intake volume dropped by 6.2 ± 14.9 oz (P = .03) during Phase 2. In Phase 3, the volume of total beverage intake returned to baseline, but the intake of potentially irritating beverages also returned to near baseline rather than 50% as requested by protocol. Despite this incomplete adherence to study protocols, women reported reduction in symptoms of urge, inability to delay voiding, and bother during both phases (P ≤ .01). The number of voids per day decreased on average by 1.3 and 0.9 voids during Phases 2 and 3, respectively (P = .002 and P = .035). Education to reduce potentially irritating beverages resulted in improvement in LUTS. However, eliminating potentially irritating beverages was difficult to achieve and maintain. Study findings do not allow us to determine whether LUTS improvement was attributable to intake of fewer potentially irritating beverages, reduced intake of all beverages, the effect of self-monitoring, or some combination of these factors.

  2. The USA National Phenology Network: A national observatory for assessment of biotic response to environmental variation

    NASA Astrophysics Data System (ADS)

    Weltzin, J. F.; USA National Phenology Network National Coordinating Office

    2011-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org), established in 2007, is a national science and monitoring initiative focused on phenology as a tool to understand how plants, animals and landscapes respond to climatic variability and change. Core functions of the National Coordinating Office (NCO) of USA-NPN are to provide a national information management system including databases, develop and implement internationally standardized phenology monitoring protocols, create partnerships with a variety of organizations including field stations for implementation, facilitate research and the development of decision support tools, and promote education and outreach activities related to phenology and climate change. This presentation will describe programs, tools and materials developed by USA-NPN to facilitate science, management and education related to phenology of plants, animals and landscapes within protected areas at local, regional and national scales. Particular emphasis will be placed on the on-line integrated animal and plant monitoring program, Nature's Notebook, which provides standardized protocols for phenological status monitoring and data management for over 500 animal and plant species. The monitoring system facilitates collection of sampling intensity, absence data, considerable metadata (from site to observation). We recently added functionality for recording estimates of animal abundance and plant canopy development. Real-time raw data for plants (from 2009 to present) and animals (from 2010 to present), including FGDC-compliant metadata and documented methodology, are now available for download from the website. A new data exploration tool premiered in spring 2010 allows sophisticated graphical visualization of integrated phenological and meteorological data. The network seeks to develop partnerships with other organizations interested in (1) implementing vetted, standardized protocols for phenological or ecological monitoring, and (2) using phenology data and information for a variety of modeling applications.

  3. Field-based evaluation of two herbaceous plant community composition sampling methods for long-term monitoring in Northern Great Plains National Parks

    USGS Publications Warehouse

    Symstad, Amy J.; Wienk, Cody L.; Thorstenson, Andy

    2006-01-01

    The Northern Great Plains Inventory & Monitoring (I&M) Network (Network) of the National Park Service (NPS) consists of 13 NPS units in North Dakota, South Dakota, Nebraska, and eastern Wyoming. The Network is in the planning phase of a long-term program to monitor the health of park ecosystems. Plant community composition is one of the 'Vital Signs,' or indicators, that will be monitored as part of this program for three main reasons. First, plant community composition is information-rich; a single sampling protocol can provide information on the diversity of native and non-native species, the abundance of individual dominant species, and the abundance of groups of plants. Second, plant community composition is of specific management concern. The abundance and diversity of exotic plants, both absolute and relative to native species, is one of the greatest management concerns in almost all Network parks (Symstad 2004). Finally, plant community composition reflects the effects of a variety of current or anticipated stressors on ecosystem health in the Network parks including invasive exotic plants, large ungulate grazing, lack of fire in a fire-adapted system, chemical exotic plant control, nitrogen deposition, increased atmospheric carbon dioxide concentrations, and climate change. Before the Network begins its Vital Signs monitoring, a detailed plan describing specific protocols used for each of the Vital Signs must go through rigorous development and review. The pilot study on which we report here is one of the components of this protocol development. The goal of the work we report on here was to determine a specific method to use for monitoring plant community composition of the herb layer (< 2 m tall).

  4. Web-based monitoring and management system for integrated enterprise-wide imaging networks

    NASA Astrophysics Data System (ADS)

    Ma, Keith; Slik, David; Lam, Alvin; Ng, Won

    2003-05-01

    Mass proliferation of IP networks and the maturity of standards has enabled the creation of sophisticated image distribution networks that operate over Intranets, Extranets, Communities of Interest (CoI) and even the public Internet. Unified monitoring, provisioning and management of such systems at the application and protocol levels represent a challenge. This paper presents a web based monitoring and management tool that employs established telecom standards for the creation of an open system that enables proactive management, provisioning and monitoring of image management systems at the enterprise level and across multi-site geographically distributed deployments. Utilizing established standards including ITU-T M.3100, and web technologies such as XML/XSLT, JSP/JSTL, and J2SE, the system allows for seamless device and protocol adaptation between multiple disparate devices. The goal has been to develop a unified interface that provides network topology views, multi-level customizable alerts, real-time fault detection as well as real-time and historical reporting of all monitored resources, including network connectivity, system load, DICOM transactions and storage capacities.

  5. A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suckling, Tara; Smith, Tony; Reed, Warren

    2013-06-15

    Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less

  6. Development of a Repeatable Regional Protocol for Performance-Based Monitoring of Forestry Best Management Practices

    Treesearch

    Roger Ryder; Pamela J. Edwards; Pamela J. Edwards

    2005-01-01

    There has been a long-standing interest in improving Best Management Practice (BMP) monitoring within and among states. States monitoring the implementation and effectiveness of BMPs for forest operations take a variety of approaches. This creates inconsistencies in data collection and how results are reported. Since 1990 attempts have been made to develop a consistent...

  7. 5.0 Monitoring methods for forests vulnerable to non-native invasive pest species

    Treesearch

    David W. Williams; Michael E. Montgomery; Kathleen S. Shields; Richard A. Evans

    2008-01-01

    Non-native invasive species pose a serious threat to forest resources, requiring programs to monitor their spatial spread and the damage they inflict on forest ecosystems. Invasive species research in the Delaware River Basin (DRB) had three primary objectives: to develop and evaluate monitoring protocols for selected pests and resulting ecosystem damage at the IMRAs...

  8. A simple protocol using underwater epoxy to install annual temperature monitoring sites in rivers and streams

    Treesearch

    Daniel J. Isaak; Dona L. Horan; Sherry P. Wollrab

    2013-01-01

    Thermal regimes in rivers and streams are fundamental determinants of biological processes and are often monitored for regulatory compliance. Here, we describe a simple technique for establishing annual monitoring sites that uses underwater epoxy to attach miniature sensors to large rocks and cement bridge supports, which then serve as protective anchors. More than 500...

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Xin, E-mail: xinshih86029@gmail.com; Zhao, Xiangmo, E-mail: xinshih86029@gmail.com; Hui, Fei, E-mail: xinshih86029@gmail.com

    Clock synchronization in wireless sensor networks (WSNs) has been studied extensively in recent years and many protocols are put forward based on the point of statistical signal processing, which is an effective way to optimize accuracy. However, the accuracy derived from the statistical data can be improved mainly by sufficient packets exchange, which will consume the limited power resources greatly. In this paper, a reliable clock estimation using linear weighted fusion based on pairwise broadcast synchronization is proposed to optimize sync accuracy without expending additional sync packets. As a contribution, a linear weighted fusion scheme for multiple clock deviations ismore » constructed with the collaborative sensing of clock timestamp. And the fusion weight is defined by the covariance of sync errors for different clock deviations. Extensive simulation results show that the proposed approach can achieve better performance in terms of sync overhead and sync accuracy.« less

  10. Variation in Anticonvulsant Selection and Electroencephalographic Monitoring Following Severe Traumatic Brain Injury in Children-Understanding Resource Availability in Sites Participating in a Comparative Effectiveness Study.

    PubMed

    Kurz, Jonathan E; Poloyac, Samuel M; Abend, Nicholas S; Fabio, Anthony; Bell, Michael J; Wainwright, Mark S

    2016-07-01

    Early posttraumatic seizures may contribute to worsened outcomes after traumatic brain injury. Evidence to guide the evaluation and management of early posttraumatic seizures in children is limited. We undertook a survey of current practices of continuous electroencephalographic monitoring, seizure prophylaxis, and the management of early posttraumatic seizures to provide essential information for trial design and the development of posttraumatic seizure management pathways. Surveys were sent to site principal investigators at all 43 sites participating in the Approaches and Decisions in Acute Pediatric TBI trial at the time of the survey. Surveys consisted of 12 questions addressing strategies to 1) implement continuous electroencephalographic monitoring, 2) posttraumatic seizure prophylaxis, 3) treat acute posttraumatic seizures, 4) treat status epilepticus and refractory status epilepticus, and 5) monitor antiseizure drug levels. Institutions comprised a mixture of free-standing children's hospitals and university medical centers across the United States and Europe. Site principal investigators of the Approaches and Decisions in Acute Pediatric TBI trial. None. Continuous electroencephalographic monitoring was available in the PICU in the overwhelming majority of clinical sites (98%); however, the plans to operationalize such monitoring for children varied considerably. A similar majority of sites report that administration of prophylactic antiseizure medications is anticipated in children (93%); yet, a minority reports that a specified protocol for treatment of posttraumatic seizures is in place (43%). Reported medication choices varied substantially between sites, but the majority of sites reported pentobarbital for refractory status epilepticus (81%). The presence of treatment protocols for seizure prophylaxis, early posttraumatic seizures, posttraumatic status epilepticus, and refractory status epilepticus was associated with decreased reported medications (all p < 0.05). This study reports the current management practices for early posttraumatic seizures in select academic centers after pediatric severe traumatic brain injury. The substantial variation in continuous electroencephalographic monitoring implementation, choice of seizure prophylaxis medications, and management of early posttraumatic seizures across institutions was reported, signifying the areas of clinical uncertainty that will help provide focused design of clinical trials. Although sites with treatment protocols reported a decreased number of medications for the scenarios described, completion of the Approaches and Decisions in Acute Pediatric TBI trial will be able to determine if these protocols lead to decreased variability in medication administration in children at the clinical sites.

  11. Comparison of low- and ultralow-dose computed tomography protocols for quantitative lung and airway assessment.

    PubMed

    Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C

    2017-09-01

    Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction, and equivalent diameter had smaller measurement differences than area and perimeter measurements. In conclusion, the use of IR with low- and ultralow-dose CT protocols with CT volume dose indices down to 0.32 mGy maintains selected quantitative parenchymal and airway measurements relevant to pulmonary disease characterization. © 2017 American Association of Physicists in Medicine.

  12. Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?

    PubMed

    Ho, Lisa M; Nelson, Rendon C; Delong, David M

    2007-05-01

    To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.

  13. Delay-tolerant mobile network protocol for rice field monitoring using wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Guitton, Alexandre; Andres, Frédéric; Cardoso, Jarbas Lopes; Kawtrakul, Asanee; Barbin, Silvio E.

    2015-10-01

    The monitoring of rice fields can improve productivity by helping farmers throughout the rice cultivation cycle, on various issues: when to harvest, when to treat the crops against disease, when to increase the water level, how to share observations and decisions made in a collaborative way, etc. In this paper, we propose an architecture to monitor a rice field by a wireless sensor network. Our architecture is based on static sensor nodes forming a disconnected network, and mobile nodes communicating with the sensor nodes in a delay-tolerant manner. The data collected by the static sensor nodes are transmitted to mobile nodes, which in turn transmit them to a gateway, connected to a database, for further analysis. We focus on the related architecture, as well as on the energy-efficient protocols intended to perform the data collection.

  14. 40 CFR 75.1 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring systems and provisions to account for missing data from certified continuous emission monitoring... estimation procedures for missing data are included in appendix C to this part. Optional protocols for...), and carbon dioxide (CO2) emissions, volumetric flow, and opacity data from affected units under the...

  15. 40 CFR 75.1 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring systems and provisions to account for missing data from certified continuous emission monitoring... estimation procedures for missing data are included in appendix C to this part. Optional protocols for...), and carbon dioxide (CO2) emissions, volumetric flow, and opacity data from affected units under the...

  16. 40 CFR 75.1 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring systems and provisions to account for missing data from certified continuous emission monitoring... estimation procedures for missing data are included in appendix C to this part. Optional protocols for...), and carbon dioxide (CO2) emissions, volumetric flow, and opacity data from affected units under the...

  17. 40 CFR 63.783 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... handling and transfer of VOHAP-containing materials to and from containers, tanks, vats, drums, and piping systems is conducted in a manner that minimizes spills. (2) All containers, tanks, vats, drums, and piping... monitoring protocol that includes operating parameter values to be monitored for compliance and an...

  18. 40 CFR 63.783 - Standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... handling and transfer of VOHAP-containing materials to and from containers, tanks, vats, drums, and piping systems is conducted in a manner that minimizes spills. (2) All containers, tanks, vats, drums, and piping... monitoring protocol that includes operating parameter values to be monitored for compliance and an...

  19. Construction and Operation of a High-Speed, High-Precision Eye Tracker for Tight Stimulus Synchronization and Real-Time Gaze Monitoring in Human and Animal Subjects.

    PubMed

    Farivar, Reza; Michaud-Landry, Danny

    2016-01-01

    Measurements of the fast and precise movements of the eye-critical to many vision, oculomotor, and animal behavior studies-can be made non-invasively by video oculography. The protocol here describes the construction and operation of a research-grade video oculography system with ~0.1° precision over the full typical viewing range at over 450 Hz with tight synchronization with stimulus onset. The protocol consists of three stages: (1) system assembly, (2) calibration for both cooperative, and for minimally cooperative subjects (e.g., animals or infants), and (3) gaze monitoring and recording.

  20. Representativeness comparisons of nurse and computer charting of heart rate across nursing-intensity protocols.

    PubMed

    Luna, Jorge M; Yip, Natalie; Pivovarov, Rimma; Vawdrey, David K

    2016-08-01

    Clinical teams in acute inpatient settings can greatly benefit from automated charting technologies that continuously monitor patient vital status. NewYork-Presbyterian has designed and developed a real-time patient monitoring system that integrates vital signs sensors, networking, and electronic health records, to allow for automatic charting of patient status. We evaluate the representativeness (a combination of agreement, safety and timing) of a core vital sign across nursing intensity care protocols for preliminary feasibility assessment. Our findings suggest an automated way of summarizing heart rate provides representation of true heart rate status and can facilitate alternatives approaches to burdensome manual nurse charting of physiological parameters.

  1. Channel Access in Erlang

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicklaus, Dennis J.

    2013-10-13

    We have developed an Erlang language implementation of the Channel Access protocol. Included are low-level functions for encoding and decoding Channel Access protocol network packets as well as higher level functions for monitoring or setting EPICS process variables. This provides access to EPICS process variables for the Fermilab Acnet control system via our Erlang-based front-end architecture without having to interface to C/C++ programs and libraries. Erlang is a functional programming language originally developed for real-time telecommunications applications. Its network programming features and list management functions make it particularly well-suited for the task of managing multiple Channel Access circuits and PVmore » monitors.« less

  2. Monitoring eruption activity using temporal stress changes at Mount Ontake volcano.

    PubMed

    Terakawa, Toshiko; Kato, Aitaro; Yamanaka, Yoshiko; Maeda, Yuta; Horikawa, Shinichiro; Matsuhiro, Kenjiro; Okuda, Takashi

    2016-02-19

    Volcanic activity is often accompanied by many small earthquakes. Earthquake focal mechanisms represent the fault orientation and slip direction, which are influenced by the stress field. Focal mechanisms of volcano-tectonic earthquakes provide information on the state of volcanoes via stresses. Here we demonstrate that quantitative evaluation of temporal stress changes beneath Mt. Ontake, Japan, using the misfit angles of focal mechanism solutions to the regional stress field, is effective for eruption monitoring. The moving average of misfit angles indicates that during the precursory period the local stress field beneath Mt. Ontake was deviated from the regional stress field, presumably by stress perturbations caused by the inflation of magmatic/hydrothermal fluids, which was removed immediately after the expulsion of volcanic ejecta. The deviation of the local stress field can be an indicator of increases in volcanic activity. The proposed method may contribute to the mitigation of volcanic hazards.

  3. Monitoring eruption activity using temporal stress changes at Mount Ontake volcano

    PubMed Central

    Terakawa, Toshiko; Kato, Aitaro; Yamanaka, Yoshiko; Maeda, Yuta; Horikawa, Shinichiro; Matsuhiro, Kenjiro; Okuda, Takashi

    2016-01-01

    Volcanic activity is often accompanied by many small earthquakes. Earthquake focal mechanisms represent the fault orientation and slip direction, which are influenced by the stress field. Focal mechanisms of volcano-tectonic earthquakes provide information on the state of volcanoes via stresses. Here we demonstrate that quantitative evaluation of temporal stress changes beneath Mt. Ontake, Japan, using the misfit angles of focal mechanism solutions to the regional stress field, is effective for eruption monitoring. The moving average of misfit angles indicates that during the precursory period the local stress field beneath Mt. Ontake was deviated from the regional stress field, presumably by stress perturbations caused by the inflation of magmatic/hydrothermal fluids, which was removed immediately after the expulsion of volcanic ejecta. The deviation of the local stress field can be an indicator of increases in volcanic activity. The proposed method may contribute to the mitigation of volcanic hazards. PMID:26892716

  4. Standardizing CT lung density measure across scanner manufacturers.

    PubMed

    Chen-Mayer, Huaiyu Heather; Fuld, Matthew K; Hoppel, Bernice; Judy, Philip F; Sieren, Jered P; Guo, Junfeng; Lynch, David A; Possolo, Antonio; Fain, Sean B

    2017-03-01

    Computed Tomography (CT) imaging of the lung, reported in Hounsfield Units (HU), can be parameterized as a quantitative image biomarker for the diagnosis and monitoring of lung density changes due to emphysema, a type of chronic obstructive pulmonary disease (COPD). CT lung density metrics are global measurements based on lung CT number histograms, and are typically a quantity specifying either the percentage of voxels with CT numbers below a threshold, or a single CT number below which a fixed relative lung volume, nth percentile, falls. To reduce variability in the density metrics specified by CT attenuation, the Quantitative Imaging Biomarkers Alliance (QIBA) Lung Density Committee has organized efforts to conduct phantom studies in a variety of scanner models to establish a baseline for assessing the variations in patient studies that can be attributed to scanner calibration and measurement uncertainty. Data were obtained from a phantom study on CT scanners from four manufacturers with several protocols at various tube potential voltage (kVp) and exposure settings. Free from biological variation, these phantom studies provide an assessment of the accuracy and precision of the density metrics across platforms solely due to machine calibration and uncertainty of the reference materials. The phantom used in this study has three foam density references in the lung density region, which, after calibration against a suite of Standard Reference Materials (SRM) foams with certified physical density, establishes a HU-electron density relationship for each machine-protocol. We devised a 5-step calibration procedure combined with a simplified physical model that enabled the standardization of the CT numbers reported across a total of 22 scanner-protocol settings to a single energy (chosen at 80 keV). A standard deviation was calculated for overall CT numbers for each density, as well as by scanner and other variables, as a measure of the variability, before and after the standardization. In addition, a linear mixed-effects model was used to assess the heterogeneity across scanners, and the 95% confidence interval of the mean CT number was evaluated before and after the standardization. We show that after applying the standardization procedures to the phantom data, the instrumental reproducibility of the CT density measurement of the reference foams improved by more than 65%, as measured by the standard deviation of the overall mean CT number. Using the lung foam that did not participate in the calibration as a test case, a mixed effects model analysis shows that the 95% confidence intervals are [-862.0 HU, -851.3 HU] before standardization, and [-859.0 HU, -853.7 HU] after standardization to 80 keV. This is in general agreement with the expected CT number value at 80 keV of -855.9 HU with 95% CI of [-857.4 HU, -854.5 HU] based on the calibration and the uncertainty in the SRM certified density. This study provides a quantitative assessment of the variations expected in CT lung density measures attributed to non-biological sources such as scanner calibration and scanner x-ray spectrum and filtration. By removing scanner-protocol dependence from the measured CT numbers, higher accuracy and reproducibility of quantitative CT measures were attainable. The standardization procedures developed in study may be explored for possible application in CT lung density clinical data. © 2017 American Association of Physicists in Medicine.

  5. A hash based mutual RFID tag authentication protocol in telecare medicine information system.

    PubMed

    Srivastava, Keerti; Awasthi, Amit K; Kaul, Sonam D; Mittal, R C

    2015-01-01

    Radio Frequency Identification (RFID) is a technology which has multidimensional applications to reduce the complexity of today life. Everywhere, like access control, transportation, real-time inventory, asset management and automated payment systems etc., RFID has its enormous use. Recently, this technology is opening its wings in healthcare environments, where potential applications include patient monitoring, object traceability and drug administration systems etc. In this paper, we propose a secure RFID-based protocol for the medical sector. This protocol is based on hash operation with synchronized secret. The protocol is safe against active and passive attacks such as forgery, traceability, replay and de-synchronization attack.

  6. Ship-Shore Packet Switched Communications System.

    DTIC Science & Technology

    1986-06-01

    PERFORMING ORGANIZATION 6b OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION (If applicable ) Naval Postgraduate School 54 Naval Postgraduate School 6c...OFFICE SYMBOL 9 PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (If applicable ) 8c ADDRESS (City, State, and ZIPCode) 10 SOURCE OF FUNDING...level acknowledgement system. 37 Network Protocol Application P re sen tation Session ____ ____ ____ ___Internet TranportProtocol Network

  7. Virtual Reality Transfer Protocol (VRTP): Implementing a Monitor Application for the Real-Time Transport Protocol (RTP) Using the JAVA Media Framework (JMF)

    DTIC Science & Technology

    1999-09-01

    application, a complete specification will require one or more companion documents, as follows. 1. Profile Specification Documents A Profile...Rio de Janeiro - RJ - Brazil 21. Diretoria de Sistemas de Armas da Marinha Rua Primeiro de Marco, 118 Rio de Janeiro - RJ - Brazil CEP 20010 22

  8. Improving Ambulatory Saliva-Sampling Compliance in Pregnant Women: A Randomized Controlled Study

    PubMed Central

    Moeller, Julian; Lieb, Roselind; Meyer, Andrea H.; Loetscher, Katharina Quack; Krastel, Bettina; Meinlschmidt, Gunther

    2014-01-01

    Objective Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. Methods We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring) and a reminder intervention (use of acoustical reminders) improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. Results Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%), F(1,60)  = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%), F(1,60)  = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64) = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705) = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. Conclusions The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest informing women about objective compliance monitoring but discourage use of acoustical reminders. PMID:24465958

  9. Protocol for Monitoring Fish Assemblages in Pacific Northwest National Parks

    USGS Publications Warehouse

    Brenkman, Samuel J.; Connolly, Patrick J.

    2008-01-01

    Rivers and streams that drain from Olympic, Mount Rainier, and North Cascades National Parks are among the most protected corridors in the lower 48 States, and represent some of the largest tracts of contiguous, undisturbed habitat throughout the range of several key fish species of the Pacific Northwest. These watersheds are of high regional importance as freshwater habitat sanctuaries for native fish, where habitat conditions are characterized as having little to no disturbance from development, channelization, impervious surfaces, roads, diversions, or hydroelectric projects. Fishery resources are of high ecological and cultural importance in Pacific Northwest National Parks, and significantly contribute to economically important recreational, commercial, and tribal fisheries. This protocol describes procedures to monitor trends in fish assemblages, fish abundance, and water temperature in eight rivers and five wadeable streams in Olympic National Park during summer months, and is based on 4 years of field testing. Fish assemblages link freshwater, marine, and terrestrial ecosystems. They also serve as focal resources of national parks and are excellent indicators of ecological conditions of rivers and streams. Despite the vital importance of native anadromous and resident fish populations, there is no existing monitoring program for fish assemblages in the North Coast and Cascades Network. Specific monitoring objectives of this protocol are to determine seasonal and annual trends in: (1) fish species composition, (2) timing of migration of adult fish, (3) relative abundance, (4) age and size structure, (5) extent of non-native and hatchery fish, and (6) water temperature. To detect seasonal and annual trends in fish assemblages in reference sites, we rely on repeated and consistent annual sampling at each monitoring site. The general rationale for the repeated sampling of reference sites is to ensure that we account for the high interannual variability in fish movements and abundances in rivers. One underlying assumption is that the monitoring program is designed in perpetuity, and consequently our capability to detect trends substantially increases with time. The protocol describes sampling designs, methods, training procedures, safety considerations, data management, data analysis, and reporting. The allocation of sampling effort represents a balance between ecological considerations, a sound monitoring approach, and practical limitations caused by logistical constraints and a limited annual budget of $55,000. The widespread declines of native fish species in western North America highlights the importance and urgency of understanding trends in fish assemblages from undisturbed habitats. Seasonal and annual trends in fish assemblages will provide insights at the individual, population, and assemblage level. This protocol will allow managers to detect increases and decreases in abundance of priority management species, and occurrence of non-native, hatchery, and federally listed fish. The detection of trends in fish assemblages will allow for specific management actions that may include: implementation of more appropriate fishing regulations, evaluation of existing hatchery releases, control of non-native fish species, and prioritization of habitat restoration projects. Dissemination and communication of scientific findings on North Coast and Cascades Network fish assemblages will be a core product of this protocol, which will have much relevance to decision makers, park visitors, researchers, and educators.

  10. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    PubMed

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  11. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  12. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  13. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  14. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  15. Microprocessor-based integration of microfluidic control for the implementation of automated sensor monitoring and multithreaded optimization algorithms.

    PubMed

    Ezra, Elishai; Maor, Idan; Bavli, Danny; Shalom, Itai; Levy, Gahl; Prill, Sebastian; Jaeger, Magnus S; Nahmias, Yaakov

    2015-08-01

    Microfluidic applications range from combinatorial synthesis to high throughput screening, with platforms integrating analog perfusion components, digitally controlled micro-valves and a range of sensors that demand a variety of communication protocols. Currently, discrete control units are used to regulate and monitor each component, resulting in scattered control interfaces that limit data integration and synchronization. Here, we present a microprocessor-based control unit, utilizing the MS Gadgeteer open framework that integrates all aspects of microfluidics through a high-current electronic circuit that supports and synchronizes digital and analog signals for perfusion components, pressure elements, and arbitrary sensor communication protocols using a plug-and-play interface. The control unit supports an integrated touch screen and TCP/IP interface that provides local and remote control of flow and data acquisition. To establish the ability of our control unit to integrate and synchronize complex microfluidic circuits we developed an equi-pressure combinatorial mixer. We demonstrate the generation of complex perfusion sequences, allowing the automated sampling, washing, and calibrating of an electrochemical lactate sensor continuously monitoring hepatocyte viability following exposure to the pesticide rotenone. Importantly, integration of an optical sensor allowed us to implement automated optimization protocols that require different computational challenges including: prioritized data structures in a genetic algorithm, distributed computational efforts in multiple-hill climbing searches and real-time realization of probabilistic models in simulated annealing. Our system offers a comprehensive solution for establishing optimization protocols and perfusion sequences in complex microfluidic circuits.

  16. Guidelines for the collection of continuous stream water-temperature data in Alaska

    USGS Publications Warehouse

    Toohey, Ryan C.; Neal, Edward G.; Solin, Gary L.

    2014-01-01

    Objectives of stream monitoring programs differ considerably among many of the academic, Federal, state, tribal, and non-profit organizations in the state of Alaska. Broad inclusion of stream-temperature monitoring can provide an opportunity for collaboration in the development of a statewide stream-temperature database. Statewide and regional coordination could reduce overall monitoring cost, while providing better analyses at multiple spatial and temporal scales to improve resource decision-making. Increased adoption of standardized protocols and data-quality standards may allow for validation of historical modeling efforts with better projection calibration. For records of stream water temperature to be generally consistent, unbiased, and reproducible, data must be collected and analyzed according to documented protocols. Collection of water-temperature data requires definition of data-quality objectives, good site selection, proper selection of instrumentation, proper installation of sensors, periodic site visits to maintain sensors and download data, pre- and post-deployment verification against an NIST-certified thermometer, potential data corrections, and proper documentation, review, and approval. A study created to develop a quality-assurance project plan, data-quality objectives, and a database management plan that includes procedures for data archiving and dissemination could provide a means to standardize a statewide stream-temperature database in Alaska. Protocols can be modified depending on desired accuracy or specific needs of data collected. This document is intended to guide users in collecting time series water-temperature data in Alaskan streams and draws extensively on the broader protocols already published by the U.S. Geological Survey.

  17. A software defined RTU multi-protocol automatic adaptation data transmission method

    NASA Astrophysics Data System (ADS)

    Jin, Huiying; Xu, Xingwu; Wang, Zhanfeng; Ma, Weijun; Li, Sheng; Su, Yong; Pan, Yunpeng

    2018-02-01

    Remote terminal unit (RTU) is the core device of the monitor system in hydrology and water resources. Different devices often have different communication protocols in the application layer, which results in the difficulty in information analysis and communication networking. Therefore, we introduced the idea of software defined hardware, and abstracted the common feature of mainstream communication protocols of RTU application layer, and proposed a uniformed common protocol model. Then, various communication protocol algorithms of application layer are modularized according to the model. The executable codes of these algorithms are labeled by the virtual functions and stored in the flash chips of embedded CPU to form the protocol stack. According to the configuration commands to initialize the RTU communication systems, it is able to achieve dynamic assembling and loading of various application layer communication protocols of RTU and complete the efficient transport of sensor data from RTU to central station when the data acquisition protocol of sensors and various external communication terminals remain unchanged.

  18. Upgrading physical activity counselling in primary care in the Netherlands.

    PubMed

    Verwey, Renée; van der Weegen, Sanne; Spreeuwenberg, Marieke; Tange, Huibert; van der Weijden, Trudy; de Witte, Luc

    2016-06-01

    The systematic development of a counselling protocol in primary care combined with a monitoring and feedback tool to support chronically ill patients to achieve a more active lifestyle. An iterative user-centred design method was used to develop a counselling protocol: the Self-management Support Programme (SSP). The needs and preferences of future users of this protocol were identified by analysing the literature, through qualitative research, and by consulting an expert panel. The counselling protocol is based on the Five A's model. Practice nurses apply motivational interviewing, risk communication and goal setting to support self-management of patients in planning how to achieve a more active lifestyle. The protocol consists of a limited number of behaviour change consultations intertwined with interaction with and responses from the It's LiFe! monitoring and feedback tool. This tool provides feedback on patients' physical activity levels via an app on their smartphone. A summary of these levels is automatically sent to the general practice so that practice nurses can respond to this information. A SSP to stimulate physical activity was defined based on user requirements of care providers and patients, followed by a review by a panel of experts. By following this user-centred approach, the organization of care was carefully taken into account, which has led to a practical and affordable protocol for physical activity counselling combined with mobile technology. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. System and Method for Outlier Detection via Estimating Clusters

    NASA Technical Reports Server (NTRS)

    Iverson, David J. (Inventor)

    2016-01-01

    An efficient method and system for real-time or offline analysis of multivariate sensor data for use in anomaly detection, fault detection, and system health monitoring is provided. Models automatically derived from training data, typically nominal system data acquired from sensors in normally operating conditions or from detailed simulations, are used to identify unusual, out of family data samples (outliers) that indicate possible system failure or degradation. Outliers are determined through analyzing a degree of deviation of current system behavior from the models formed from the nominal system data. The deviation of current system behavior is presented as an easy to interpret numerical score along with a measure of the relative contribution of each system parameter to any off-nominal deviation. The techniques described herein may also be used to "clean" the training data.

  20. Lapses, infidelities, and creative adaptations: lessons from evaluation of a participatory market development approach in the Andes.

    PubMed

    Horton, Douglas; Rotondo, Emma; Paz Ybarnegaray, Rodrigo; Hareau, Guy; Devaux, André; Thiele, Graham

    2013-08-01

    Participatory approaches are frequently recommended for international development programs, but few have been evaluated. From 2007 to 2010 the Andean Change Alliance evaluated an agricultural research and development approach known as the "Participatory Market Chain Approach" (PMCA). Based on a study of four cases, this paper examines the fidelity of implementation, the factors that influenced implementation and results, and the PMCA change model. We identify three types of deviation from the intervention protocol (lapses, creative adaptations, and true infidelities) and five groups of variables that influenced PMCA implementation and results (attributes of the macro context, the market chain, the key actors, rules in use, and the capacity development strategy). There was insufficient information to test the validity of the PMCA change model, but results were greatest where the PMCA was implemented with highest fidelity. Our analysis suggests that the single most critical component of the PMCA is engagement of market agents - not just farmers - throughout the exercise. We present four lessons for planning and evaluating participatory approaches related to the use of action and change models, the importance of monitoring implementation fidelity, the limits of baseline survey data for outcome evaluation, and the importance of capacity development for implementers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Assessment of Nitrification in Distribution Systems of Waters with Elevated Ammonia Levels

    EPA Science Inventory

    The objective of this work is to monitor ammonia, nitrite, and nitrate in drinking water from the distribution systems of four drinking water utilities in Illinois. A monthly drinking water distribution system water quality monitoring protocol for each water utility in Illinois h...

  2. 76 FR 59425 - Notice of Lodging of Consent Decree Under The Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ... and collection systems, to correctly establish and monitor operating parameters, and to comply with... using model test protocols, adopt new monitoring practices, correct deficiencies in recordkeeping and... Environmental Protection Agency, Ariel Rios Building, 1200 Pennsylvania Avenue, NW., Washington, DC 20460...

  3. Soiling of building envelope surfaces and its effect on solar reflectance – Part III: Interlaboratory study of an accelerated aging method for roofing materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.

    A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less

  4. Tests for qualitative treatment-by-centre interaction using a 'pushback' procedure.

    PubMed

    Ciminera, J L; Heyse, J F; Nguyen, H H; Tukey, J W

    1993-06-15

    In multicentre clinical trials using a common protocol, the centres are usually regarded as being a fixed factor, thus allowing any treatment-by-centre interaction to be omitted from the error term for the effect of treatment. However, we feel it necessary to use the treatment-by-centre interaction as the error term if there is substantial evidence that the interaction with centres is qualitative instead of quantitative. To make allowance for the estimated uncertainties of the centre means, we propose choosing a reference value (for example, the median of the ordered array of centre means) and converting the individual centre results into standardized deviations from the reference value. The deviations are then reordered, and the results 'pushed back' by amounts appropriate for the corresponding order statistics in a sample from the relevant distribution. The pushed-back standardized deviations are then restored to the original scale. The appearance of opposite signs among the destandardized values for the various centres is then taken as 'substantial evidence' of qualitative interaction. Procedures are presented using, in any combination: (i) Gaussian, or Student's t-distribution; (ii) order-statistic medians or outward 90 per cent points of the corresponding order statistic distributions; (iii) pooling or grouping and pooling the internally estimated standard deviations of the centre means. The use of the least conservative combination--Student's t, outward 90 per cent points, grouping and pooling--is recommended.

  5. Industrial wind turbine post-construction bird and bat monitoring: A policy framework for Canada.

    PubMed

    Parisé, Jason; Walker, Tony R

    2017-10-01

    Electricity generation from wind energy has proliferated throughout North America and will continue to grow. Given Canada's expected increase in wind energy capacity, consideration of the potential adverse impacts to bird and bat populations is prudent given their sensitivity to these projects. The province of Ontario, Canada is currently the leading jurisdiction for wind energy development, and for provincial guidance on pre- and post-construction monitoring. With uniform monitoring guidance in Ontario, wind energy proponents, and third-party consultants, have developed post-construction monitoring protocols that meet provincial guidance, while also providing standardized reporting. In Atlantic Canada, post-construction guidelines vary between provinces, depending mostly on guidance from the Environment Canada Canadian Wildlife Service and relevant provincial agencies. To ensure quality post-construction monitoring results in Atlantic Canada and other provinces, it is imperative that all Canadian provinces adopt similar approaches to those employed in Ontario. This paper reviews major causes of bird and bat mortalities; reviews Canadian federal and Ontario provincial bird and bat monitoring guidelines to elucidate gaps between environmental assessment (EA) theory and application; summarizes post-construction monitoring protocols from eight bird and bat post-construction monitoring programs used in Ontario; and, proposes recommendations to support future wind development opportunities across Canada and specifically in Atlantic Canada. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. SU-E-I-22: A Comprehensive Investigation of Noise Variations Between the GE Discovery CT750 HD and GE LightSpeed VCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bache, S; Loyer, E; Stauduhar, P

    2015-06-15

    Purpose: To quantify and compare the noise properties between two GE CT models-the Discovery CT750 HD (aka HD750) and LightSpeed VCT, with the overall goal of assessing the impact in clinical diagnostic practice. Methods: Daily QC data from a fleet of 9 CT scanners currently in clinical use were investigated – 5 HD750 and 4 VCT (over 600 total acquisitions for each scanner). A standard GE QC phantom was scanned daily using two sets of scan parameters with each scanner over 1 year. Water CT number and standard deviation were recorded from the image of water section of the QCmore » phantom. The standard GE QC scan parameters (Pitch = 0.516, 120kVp, 0.4s, 335mA, Small Body SFOV, 5mm thickness) and an in-house developed protocol (Axial, 120kVp, 1.0s, 240mA, Head SFOV, 5mm thickness) were used, with Standard reconstruction algorithm. Noise was measured as the standard deviation in the center of the water phantom image. Inter-model noise distributions and tube output in mR/mAs were compared to assess any relative differences in noise properties. Results: With the in-house protocols, average noise for the five HD750 scanners was ∼9% higher than the VCT scanners (5.8 vs 5.3). For the GE QC protocol, average noise with the HD750 scanners was ∼11% higher than with the VCT scanners (4.8 vs 4.3). This discrepancy in noise between the two models was found despite the tube output in mR/mAs being comparable with the HD750 scanners only having ∼4% lower output (8.0 vs 8.3 mR/mAs). Conclusion: Using identical scan protocols, average noise in images from the HD750 group was higher than that from the VCT group. This confirms feedback from an institutional radiologist’s feedback regarding grainier patient images from HD750 scanners. Further investigation is warranted to assess the noise texture and distribution, as well as clinical impact.« less

  7. An analysis of potential stream fish and fish habitat monitoring procedures for the Inland Northwest: Annual Report 1999

    Treesearch

    James T. Peterson; Sherry P. Wollrab

    1999-01-01

    Natural resource managers in the Inland Northwest need tools for assessing the success or failure of conservation policies and the impacts of management actions on fish and fish habitats. Effectiveness monitoring is one such potential tool, but there are currently no established monitoring protocols. Since 1991, U.S. Forest Service biologists have used the standardized...

  8. Water quality monitoring for high-priority water bodies in the Sonoran Desert network

    Treesearch

    Terry W. Sprouse; Robert M. Emanuel; Sara A. Strorrer

    2005-01-01

    This paper describes a network monitoring program for “high priority” water bodies in the Sonoran Desert Network of the National Park Service. Protocols were developed for monitoring selected waters for ten of the eleven parks in the Network. Park and network staff assisted in identifying potential locations of testing sites, local priorities, and how water quality...

  9. A Survey on an Energy-Efficient and Energy-Balanced Routing Protocol for Wireless Sensor Networks.

    PubMed

    Ogundile, Olayinka O; Alfa, Attahiru S

    2017-05-10

    Wireless sensor networks (WSNs) form an important part of industrial application. There has been growing interest in the potential use of WSNs in applications such as environment monitoring, disaster management, health care monitoring, intelligence surveillance and defence reconnaissance. In these applications, the sensor nodes (SNs) are envisaged to be deployed in sizeable numbers in an outlying area, and it is quite difficult to replace these SNs after complete deployment in many scenarios. Therefore, as SNs are predominantly battery powered devices, the energy consumption of the nodes must be properly managed in order to prolong the network lifetime and functionality to a rational time. Different energy-efficient and energy-balanced routing protocols have been proposed in literature over the years. The energy-efficient routing protocols strive to increase the network lifetime by minimizing the energy consumption in each SN. On the other hand, the energy-balanced routing protocols protract the network lifetime by uniformly balancing the energy consumption among the nodes in the network. There have been various survey papers put forward by researchers to review the performance and classify the different energy-efficient routing protocols for WSNs. However, there seems to be no clear survey emphasizing the importance, concepts, and principles of load-balanced energy routing protocols for WSNs. In this paper, we provide a clear picture of both the energy-efficient and energy-balanced routing protocols for WSNs. More importantly, this paper presents an extensive survey of the different state-of-the-art energy-efficient and energy-balanced routing protocols. A taxonomy is introduced in this paper to classify the surveyed energy-efficient and energy-balanced routing protocols based on their proposed mode of communication towards the base station (BS). In addition, we classified these routing protocols based on the solution types or algorithms, and the input decision variables defined in the routing algorithm. The strengths and weaknesses of the choice of the decision variables used in the design of these energy-efficient and energy-balanced routing protocols are emphasised. Finally, we suggest possible research directions in order to optimize the energy consumption in sensor networks.

  10. A Survey on an Energy-Efficient and Energy-Balanced Routing Protocol for Wireless Sensor Networks

    PubMed Central

    Ogundile, Olayinka O.; Alfa, Attahiru S.

    2017-01-01

    Wireless sensor networks (WSNs) form an important part of industrial application. There has been growing interest in the potential use of WSNs in applications such as environment monitoring, disaster management, health care monitoring, intelligence surveillance and defence reconnaissance. In these applications, the sensor nodes (SNs) are envisaged to be deployed in sizeable numbers in an outlying area, and it is quite difficult to replace these SNs after complete deployment in many scenarios. Therefore, as SNs are predominantly battery powered devices, the energy consumption of the nodes must be properly managed in order to prolong the network lifetime and functionality to a rational time. Different energy-efficient and energy-balanced routing protocols have been proposed in literature over the years. The energy-efficient routing protocols strive to increase the network lifetime by minimizing the energy consumption in each SN. On the other hand, the energy-balanced routing protocols protract the network lifetime by uniformly balancing the energy consumption among the nodes in the network. There have been various survey papers put forward by researchers to review the performance and classify the different energy-efficient routing protocols for WSNs. However, there seems to be no clear survey emphasizing the importance, concepts, and principles of load-balanced energy routing protocols for WSNs. In this paper, we provide a clear picture of both the energy-efficient and energy-balanced routing protocols for WSNs. More importantly, this paper presents an extensive survey of the different state-of-the-art energy-efficient and energy-balanced routing protocols. A taxonomy is introduced in this paper to classify the surveyed energy-efficient and energy-balanced routing protocols based on their proposed mode of communication towards the base station (BS). In addition, we classified these routing protocols based on the solution types or algorithms, and the input decision variables defined in the routing algorithm. The strengths and weaknesses of the choice of the decision variables used in the design of these energy-efficient and energy-balanced routing protocols are emphasised. Finally, we suggest possible research directions in order to optimize the energy consumption in sensor networks. PMID:28489054

  11. 10 CFR 74.53 - Process monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATORY COMMISSION (CONTINUED) MATERIAL CONTROL AND ACCOUNTING OF SPECIAL NUCLEAR MATERIAL Formula... estimated measurement standard deviation greater than five percent that is either input or output material... results generated during an inventory period for indications of measurement biases or unidentified loss...

  12. Panama Canal Fog Navigation Study : Candidate System Definition

    DOT National Transportation Integrated Search

    1984-01-01

    A candidate system for solving fog navigation problems in the Panama Canal is defined. The vessel monitoring subsystem is a shore-based, all-weather, precision ranging system with ranging accuracies of 9 feet (2 standard deviations, 95 percent).

  13. Micro-computed tomography analysis of post space preparation in root canals filled with carrier-based thermoplasticized gutta-percha.

    PubMed

    Schroeder, A A; Ford, N L; Coil, J M

    2017-03-01

    To determine whether post space preparation deviated from the root canal preparation in canals filled with Thermafil, GuttaCore or warm vertically compacted gutta-percha. Forty-two extracted human permanent maxillary lateral incisors were decoronated, and their root canals instrumented using a standardized protocol. Samples were divided into three groups and filled with Thermafil (Dentsply Tulsa Dental Specialties, Johnson City, TN, USA), GuttaCore (Dentsply Tulsa Dental Specialties) or warm vertically compacted gutta-percha, before post space preparation was performed with a GT Post drill (Dentsply Tulsa Dental Specialties). Teeth were scanned using micro-computed tomography after root filling and again after post space preparation. Scans were examined for number of samples with post space deviation, linear deviation of post space preparation and minimum root thickness before and after post space preparation. Parametric data were analysed with one-way analysis of variance (anova) or one-tailed paired Student's t-tests, whilst nonparametric data were analysed with Fisher's exact test. Deviation occurred in eight of forty-two teeth (19%), seven of fourteen from the Thermafil group (50%), one of fourteen from the GuttaCore group (7%), and none from the gutta-percha group. Deviation occurred significantly more often in the Thermafil group than in each of the other two groups (P < 0.05). Linear deviation of post space preparation was greater in the Thermafil group than in both of the other groups and was significantly greater than that of the gutta-percha group (P < 0.05). Minimum root thickness before post space preparation was significantly greater than it was after post space preparation for all groups (P < 0.01). The differences between the Thermafil, GuttaCore and gutta-percha groups in the number of samples with post space deviation and in linear deviation of post space preparation were associated with the presence or absence of a carrier as well as the different carrier materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Calibration of coronary calcium scores determined using iterative image reconstruction (AIDR 3D) at 120, 100, and 80 kVp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blobel, Joerg, E-mail: Joerg.Blobel@toshiba-medical.eu; Mews, Juergen; Schuijf, Joanne D.

    Purpose: Computed tomography (CT) radiation dose reduction is frequently achieved by applying lower tube voltages and using iterative reconstruction (IR). For calcium scoring, the reference protocol at 120 kVp with filtered back projection (FBP) is still used, because kVp and IR may influence the Agatston score (AS) and volume score (VS). The authors present a two-step method to optimize dose: first, to determine the lowest feasible exposure and highest noise thresholds; second, to define a calibration method that ensures that the AS and VS are similar to the reference protocol. Methods: AS and VS were measured for an anthropomorphic thoracicmore » phantom that includes a calcium calibration module. The phantom was scanned on a 320-row CT scanner, at tube voltages of 120 kVp using FBP, and 120, 100, and 80 kVp using adaptive iterative dose reduction (AIDR 3D) reconstruction. The minimum CTDIs were determined based on three objective quality criteria. Calibration was performed to estimate adjusted CT number thresholds for the lower kVp acquisitions. Finally, the accuracies of the total and individual insert scores at dose level close to the minimum CTDI level were investigated and compared to low (FBP{sub LD} − 120) and high (FBP{sub HD} − 120) dose reference protocols (based on ten repeated acquisitions for each group). Results: IR allows the exposure to be reduced by 69% at 120 kVp, with no significant effect on the total scores when averaged over all included dose steps and compared to FBP-120 (AS: 693 vs 699, p = 0.182; VS: 588 vs 587 mm{sup 3}, p = 0.569). Also when averaged over ten repeated scans and compared to FBP{sub HD} − 120 (AS: 709 vs 704, p = 0.435; VS: 604 vs 601 mm{sup 3}, p = 0.479), there is no statistical significant effect. Reducing the peak tube voltage allows even greater dose reductions: 73% at 100 kVp and 76% at 80 kVp. The calibrated CT number thresholds for analysis at 120, 100, and 80 kVp were, respectively, 130, 133, and 160 HU for the Agatston score, and 130, 132, and 140 HU for the volume score. Following the calibration, the mean scores of the four groups with dose variation were not significantly different from the reference protocol, at 100 kVp (AS: 698 vs 699, p = 0.818; VS: 584 vs 587 mm{sup 3}, p = 0.365) or at 80 kVp (AS: 698 vs 699, p = 0.996; VS: 586 vs 587 mm{sup 3}, p = 0.827). Similarly, there was no significant score difference with FBP{sub LD} − 120 during repeated scanning: 100 kVp (AS: 690 vs 694, p = 0.394; VS: 579 vs 585 mm{sup 3}, p = 0.168) and 80 kVp (AS: 703 vs 694, p = 0.115; VS: 588 vs 585 mm{sup 3}, p = 0.613). Compared to FBP{sub HD} − 120 group, the relative score deviation for the accuracy of the 400 and 800 mg/cm{sup 3} HA inserts with 3 and 5 mm diameter is less than 7%. However, the relative deviation of the smaller 1 mm inserts is poorer (up to 41% deviations for scores <3). Conclusions: With iterative reconstruction using AIDR 3D, deviations of the total Agatston and volume scores remain within 4% of the reference protocol. The 1 mm inserts were detected as calcification, but scores less than ten tend to be underestimated. Following the calibration process, the application of IR in combination with reduced tube voltages allows up to 76% lower radiation dose.« less

  15. An International Haze-Monitoring Network for Students.

    ERIC Educational Resources Information Center

    Mims, Forrest M.

    1999-01-01

    Describes the haze-monitoring program that was added to the protocols of the Global Learning and Observations to Benefit the Environment (GLOBE) Program. Finds that sun photometry provides a convenient means for allowing students to perform hands-on science while learning about various topics in history, electronics, algebra, statistics, graphing,…

  16. Bridge scour monitoring technologies : development of evaluation and selection protocols for application on river bridges in Minnesota.

    DOT National Transportation Integrated Search

    2010-03-01

    Bridge failure or loss of structural integrity can result from scour of riverbed sediment near bridge abutments or : piers during high-flow events in rivers. In the past 20 years, several methods of monitoring bridge scour have been : developed spann...

  17. Protocols for vegetation and habitat monitoring with unmanned aerial vehicles: linking research to management on US public lands

    USDA-ARS?s Scientific Manuscript database

    Background/Question/Methods: Monitoring of the condition and trend of natural resources is critical for determining effectiveness of management actions and understanding ecosystem responses to broad-scale processes like climate change. While broad-scale remote sensing has generally improved the abi...

  18. COMPLEMENTARY MONITORING DESIGNS TO DOCUMENT REGIONAL GRADIENTS, AND TEMPORTAL VARIATIONS OF DISSOLOVED OXYGEN IN ESTUARINE WATERS

    EPA Science Inventory

    The U.S. EPA National Coastal Assessment program is designed to address two broad questions: 1) what are the conditions of estuarine resources, how are they changing, and what causes those changes; 2) which monitoring designs, indicators, and protocols are appropriate for assessi...

  19. 50 CFR 18.118 - What are the mitigation, monitoring, and reporting requirements?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... monitoring and research efforts will employ rigorous study designs and sampling protocols in order to provide... mitigation measures for offshore seismic surveys. Any offshore exploration activity expected to include the... 1 µPa. (ii) Ramp-up procedures. For all seismic surveys, including airgun testing, use the following...

  20. 50 CFR 18.118 - What are the mitigation, monitoring, and reporting requirements?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... monitoring and research efforts will employ rigorous study designs and sampling protocols in order to provide... mitigation measures for offshore seismic surveys. Any offshore exploration activity expected to include the... 1 µPa. (ii) Ramp-up procedures. For all seismic surveys, including airgun testing, use the following...

  1. Calibration of the Delaware Rapid Assessment Protocol to a Comprehensive Measure of Wetland Condition

    EPA Science Inventory

    The importance of monitoring and assessment to the management and protection of wetlands has been recognized, and research in recent years has made progress in the development of wetland monitoring and assessment tools. Wetland assessments are made at multiple levels of intensit...

  2. SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chinsky, B; Patel, R; Roeske, J

    Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations andmore » those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.« less

  3. Optimization of oligonucleotide arrays and RNA amplification protocols for analysis of transcript structure and alternative splicing.

    PubMed

    Castle, John; Garrett-Engele, Phil; Armour, Christopher D; Duenwald, Sven J; Loerch, Patrick M; Meyer, Michael R; Schadt, Eric E; Stoughton, Roland; Parrish, Mark L; Shoemaker, Daniel D; Johnson, Jason M

    2003-01-01

    Microarrays offer a high-resolution means for monitoring pre-mRNA splicing on a genomic scale. We have developed a novel, unbiased amplification protocol that permits labeling of entire transcripts. Also, hybridization conditions, probe characteristics, and analysis algorithms were optimized for detection of exons, exon-intron edges, and exon junctions. These optimized protocols can be used to detect small variations and isoform mixtures, map the tissue specificity of known human alternative isoforms, and provide a robust, scalable platform for high-throughput discovery of alternative splicing.

  4. Optimization of oligonucleotide arrays and RNA amplification protocols for analysis of transcript structure and alternative splicing

    PubMed Central

    Castle, John; Garrett-Engele, Phil; Armour, Christopher D; Duenwald, Sven J; Loerch, Patrick M; Meyer, Michael R; Schadt, Eric E; Stoughton, Roland; Parrish, Mark L; Shoemaker, Daniel D; Johnson, Jason M

    2003-01-01

    Microarrays offer a high-resolution means for monitoring pre-mRNA splicing on a genomic scale. We have developed a novel, unbiased amplification protocol that permits labeling of entire transcripts. Also, hybridization conditions, probe characteristics, and analysis algorithms were optimized for detection of exons, exon-intron edges, and exon junctions. These optimized protocols can be used to detect small variations and isoform mixtures, map the tissue specificity of known human alternative isoforms, and provide a robust, scalable platform for high-throughput discovery of alternative splicing. PMID:14519201

  5. A Multi-Center Space Data System Prototype Based on CCSDS Standards

    NASA Technical Reports Server (NTRS)

    Rich, Thomas M.

    2016-01-01

    Deep space missions beyond earth orbit will require new methods of data communications in order to compensate for increasing RF propagation delay. The Consultative Committee for Space Data Systems (CCSDS) standard protocols Spacecraft Monitor & Control (SM&C), Asynchronous Message Service (AMS), and Delay/Disruption Tolerant Networking (DTN) provide such a method. The maturity level of this protocol set is, however, insufficient for mission inclusion at this time. This prototype is intended to provide experience which will raise the Technical Readiness Level (TRL) of these protocols..

  6. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.

    PubMed

    Georg, Dietmar; Stock, Markus; Kroupa, Bernhard; Olofsson, Jörgen; Nyholm, Tufve; Ahnesjö, Anders; Karlsson, Mikael

    2007-08-21

    Experimental methods are commonly used for patient-specific intensity-modulated radiotherapy (IMRT) verification. The purpose of this study was to investigate the accuracy and performance of independent dose calculation software (denoted as 'MUV' (monitor unit verification)) for patient-specific quality assurance (QA). 52 patients receiving step-and-shoot IMRT were considered. IMRT plans were recalculated by the treatment planning systems (TPS) in a dedicated QA phantom, in which an experimental 1D and 2D verification (0.3 cm(3) ionization chamber; films) was performed. Additionally, an independent dose calculation was performed. The fluence-based algorithm of MUV accounts for collimator transmission, rounded leaf ends, tongue-and-groove effect, backscatter to the monitor chamber and scatter from the flattening filter. The dose calculation utilizes a pencil beam model based on a beam quality index. DICOM RT files from patient plans, exported from the TPS, were directly used as patient-specific input data in MUV. For composite IMRT plans, average deviations in the high dose region between ionization chamber measurements and point dose calculations performed with the TPS and MUV were 1.6 +/- 1.2% and 0.5 +/- 1.1% (1 S.D.). The dose deviations between MUV and TPS slightly depended on the distance from the isocentre position. For individual intensity-modulated beams (total 367), an average deviation of 1.1 +/- 2.9% was determined between calculations performed with the TPS and with MUV, with maximum deviations up to 14%. However, absolute dose deviations were mostly less than 3 cGy. Based on the current results, we aim to apply a confidence limit of 3% (with respect to the prescribed dose) or 6 cGy for routine IMRT verification. For off-axis points at distances larger than 5 cm and for low dose regions, we consider 5% dose deviation or 10 cGy acceptable. The time needed for an independent calculation compares very favourably with the net time for an experimental approach. The physical effects modelled in the dose calculation software MUV allow accurate dose calculations in individual verification points. Independent calculations may be used to replace experimental dose verification once the IMRT programme is mature.

  7. SMS-Based Medical Diagnostic Telemetry Data Transmission Protocol for Medical Sensors

    PubMed Central

    Townsend, Ben; Abawajy, Jemal; Kim, Tai-Hoon

    2011-01-01

    People with special medical monitoring needs can, these days, be sent home and remotely monitored through the use of data logging medical sensors and a transmission base-station. While this can improve quality of life by allowing the patient to spend most of their time at home, most current technologies rely on hardwired landline technology or expensive mobile data transmissions to transmit data to a medical facility. The aim of this paper is to investigate and develop an approach to increase the freedom of a monitored patient and decrease costs by utilising mobile technologies and SMS messaging to transmit data from patient to medico. To this end, we evaluated the capabilities of SMS and propose a generic communications protocol which can work within the constraints of the SMS format, but provide the necessary redundancy and robustness to be used for the transmission of non-critical medical telemetry from data logging medical sensors. PMID:22163845

  8. Evaluation of a realtime, remote monitoring telemedicine system using the Bluetooth protocol and a mobile phone network.

    PubMed

    Jasemian, Yousef; Arendt-Nielsen, Lars

    2005-01-01

    A generic, realtime wireless telemedicine system has been developed that uses the Bluetooth protocol and the general packet radio service for mobile phones. The system was tested on 10 healthy volunteers, by continuous monitoring of their electrocardiograms (ECGs). Under realistic conditions, the system had 96.5% uptime, a data throughput of 3.3 kbit/s, a mean packet error rate of 8.5x10(-3) packet/s and a mean packet loss rate of 8.2x10(-3) packet/s. During 24 h testing, the total average downtime was 66 min and 90% of the periods of downtime were of only 1-3 min duration. Less than 10% of the ECGs were of unacceptable quality. Thus, the generic telemedicine system showed high reliability and performance, and the design may provide a foundation for realtime monitoring in clinical practice, for example in cardiology.

  9. Maintaining Perioperative Normothermia: Sustaining an Evidence-Based Practice Improvement Project.

    PubMed

    Levin, Rona F; Wright, Fay; Pecoraro, Kathleen; Kopec, Wendy

    2016-02-01

    Unintentional perioperative hypothermia has been shown to cause serious patient complications and, thus, to increase health care costs. In 2009, an evidence-based practice improvement project produced a significant decrease in unintentional perioperative hypothermia in colorectal surgical patients through monitoring of OR ambient room temperature. Project leaders engaged all interdisciplinary stakeholders in the original project, which facilitated the sustainability of the intervention method. An important aspect of sustainability is ongoing monitoring and evaluation of a new intervention method. Therefore, continued evaluation of outcomes of the protocol developed in 2009 was scheduled at specific time points after the initial small test of change with colorectal patients. This article focuses on how attention to sustainability factors during implementation of an improvement project led to the sustainability of a protocol for monitoring OR ambient room temperature with all types of surgical patients five years after the initial project. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  10. Secure and Efficient Network Fault Localization

    DTIC Science & Technology

    2012-02-27

    ORGANIZATION NAME(S) AND ADDRESS (ES) Carnegie Mellon University,School of Computer Science,Computer Science Department,Pittsburgh,PA,15213 8. PERFORMING...ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS (ES) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT...efficiency than previously known protocols for fault localization. Our proposed fault localization protocols also address the security threats that

  11. Progress toward developing field protocols for a North American marsh bird monitoring program

    Treesearch

    Courtney J. Conway; Steven T. A. Timmermans

    2005-01-01

    Populations of many marsh-dependent birds appear to be declining, but we currently lack a continental program that provides estimates of population trends for most secretive marshbirds. The survey protocol outlined here is a standardized survey methodology being used on a pilot basis at National Wildlife Refuges and other protected wetland areas across North America...

  12. iSAFT Protocol Validation Platform for On-Board Data Networks

    NASA Astrophysics Data System (ADS)

    Tavoularis, Antonis; Kollias, Vangelis; Marinis, Kostas

    2014-08-01

    iSAFT is an integrated powerful HW/SW environmentfor the simulation, validation & monitoring of satellite/spacecraft on-board data networks supporting simultaneously a wide range of protocols (RMAP, PTP, CCSDS Space Packet, TM/TC, CANopen, etc.) and network interfaces (SpaceWire, ECSS MIL-STD-1553, ECSS CAN). It is based on over 20 years of TELETEL's experience in the area of protocol validation in the telecommunications and aeronautical sectors, and it has been fully re-engineered in cooperation of TELETEL with ESA & space Primes, to comply with space on-board industrial validation requirements (ECSS, EGSE, AIT, AIV, etc.). iSAFT is highly modular and expandable to support new network interfaces & protocols and it is based on the powerful iSAFT graphical tool chain (Protocol Analyser / Recorder, TestRunner, Device Simulator, Traffic Generator, etc.).

  13. Image guidance in prostate cancer - can offline corrections be an effective substitute for daily online imaging?

    PubMed

    Prasad, Devleena; Das, Pinaki; Saha, Niladri S; Chatterjee, Sanjoy; Achari, Rimpa; Mallick, Indranil

    2014-01-01

    This aim of this study was to determine if a less resource-intensive and established offline correction protocol - the No Action Level (NAL) protocol was as effective as daily online corrections of setup deviations in curative high-dose radiotherapy of prostate cancer. A total of 683 daily megavoltage CT (MVCT) or kilovoltage CT (kvCBCT) images of 30 patients with localized prostate cancer treated with intensity modulated radiotherapy were evaluated. Daily image-guidance was performed and setup errors in three translational axes recorded. The NAL protocol was simulated by using the mean shift calculated from the first five fractions and implemented on all subsequent treatments. Using the imaging data from the remaining fractions, the daily residual error (RE) was determined. The proportion of fractions where the RE was greater than 3,5 and 7 mm was calculated, and also the actual PTV margin that would be required if the offline protocol was followed. Using the NAL protocol reduced the systematic but not the random errors. Corrections made using the NAL protocol resulted in small and acceptable RE in the mediolateral (ML) and superoinferior (SI) directions with 46/533 (8.1%) and 48/533 (5%) residual shifts above 5 mm. However; residual errors greater than 5mm in the anteroposterior (AP) direction remained in 181/533 (34%) of fractions. The PTV margins calculated based on residual errors were 5mm, 5mm and 13 mm in the ML, SI and AP directions respectively. Offline correction using the NAL protocol resulted in unacceptably high residual errors in the AP direction, due to random uncertainties of rectal and bladder filling. Daily online imaging and corrections remain the standard image guidance policy for highly conformal radiotherapy of prostate cancer.

  14. Comparison of butorphanol-detomidine versus butorphanol-azaperone for the standing sedation of captive greater one-horned rhinoceroses (Rhinoceros unicornis).

    PubMed

    Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A

    2014-03-01

    Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.

  15. Importance of Standardized DXA Protocol for Assessing Physique Changes in Athletes.

    PubMed

    Nana, Alisa; Slater, Gary J; Hopkins, Will G; Halson, Shona L; Martin, David T; West, Nicholas P; Burke, Louise M

    2016-06-01

    The implications of undertaking DXA scans using best practice protocols (subjects fasted and rested) or a less precise but more practical protocol in assessing chronic changes in body composition following training and a specialized recovery technique were investigated. Twenty-one male cyclists completed an overload training program, in which they were randomized to four sessions per week of either cold water immersion therapy or control groups. Whole-body DXA scans were undertaken with best practice protocol (Best) or random activity protocol (Random) at baseline, after 3 weeks of overload training, and after a 2-week taper. Magnitudes of changes in total, lean and fat mass from baseline-overload, overload-taper and baseline-taper were assessed by standardization (Δmean/SD). The standard deviations of change scores for total and fat-free soft tissue mass (FFST) from Random scans (2-3%) were approximately double those observed in the Best (1-2%), owing to extra random errors associated with Random scans at baseline. There was little difference in change scores for fat mass. The effect of cold water immersion therapy on baseline-taper changes in FFST was possibly harmful (-0.7%; 90% confidence limits ±1.2%) with Best scans but unclear with Random scans (0.9%; ±2.0%). Both protocols gave similar possibly harmful effects of cold water immersion therapy on changes in fat mass (6.9%; ±13.5% and 5.5%; ±14.3%, respectively). An interesting effect of cold water immersion therapy on training-induced changes in body composition might have been missed with a less precise scanning protocol. DXA scans should be undertaken with Best.

  16. An ethernet/IP security review with intrusion detection applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laughter, S. A.; Williams, R. D.

    2006-07-01

    Supervisory Control and Data Acquisition (SCADA) and automation networks, used throughout utility and manufacturing applications, have their own specific set of operational and security requirements when compared to corporate networks. The modern climate of heightened national security and awareness of terrorist threats has made the security of these systems of prime concern. There is a need to understand the vulnerabilities of these systems and how to monitor and protect them. Ethernet/IP is a member of a family of protocols based on the Control and Information Protocol (CIP). Ethernet/IP allows automation systems to be utilized on and integrated with traditional TCP/IPmore » networks, facilitating integration of these networks with corporate systems and even the Internet. A review of the CIP protocol and the additions Ethernet/IP makes to it has been done to reveal the kind of attacks made possible through the protocol. A set of rules for the SNORT Intrusion Detection software is developed based on the results of the security review. These can be used to monitor, and possibly actively protect, a SCADA or automation network that utilizes Ethernet/IP in its infrastructure. (authors)« less

  17. [Prediction of cardiac function deviations (ECG data) in the course of permanent cosmonaut's monitoring starting from selection till return to earth after short-duration space flight].

    PubMed

    Kotovskaia, A R; Koloteva, M I; Luk'ianiuk, V Iu; Stepanova, G P; Filatova, L M; Buĭlov, S P; Zhernavkov, A F; Kondratiuk, L L

    2007-01-01

    Analyzed were deviations in cardiac function in 29 cosmonauts with previous aviation and other occupations ranging of 29 to 61 y.o. who made 8- to 30-day space flights (totai number of flights = 34) between 1982 and 2006. The deviations were identified in ECG records collected during clinical selection, clinical physiological examination (CPE) before flight, insertion and deorbit in transport vehicles, and post-flight CPE. Based on the analysis, the cosmonauts were distributed into three groups. The first group (55.2% of the cosmonauts) did not exhibit noticeable shifts and unfavorable trends in ECG at any time of the period of observation. The second group (34.5%) showed some deviations during selection and pre-flight CPE that became more apparent in the period of deorbit and were still present in post-flight ECG records. The third group (10.3%) displayed health-threatening deviations in cardiac function during deorbit. These findings give start to important investigations with the purpose to define permissible medical risks and ensuing establishment and perfection of medical criteria for candidates to cosmonauts with certain health problems.

  18. Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy.

    PubMed

    Andersen, Claus E; Nielsen, Søren Kynde; Lindegaard, Jacob Christian; Tanderup, Kari

    2009-11-01

    The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with 192Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from +/-5 to +/-15 mm) were simulated in software in order to assess the ability of the system to detect errors. For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a +/-15 mm displacement error increased by a factor of 1.5 or more. In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bamberger, Judith A.; Piepel, Gregory F.; Enderlin, Carl W.

    Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests weremore » conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.« less

  20. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

Top